WorldWideScience

Sample records for extremely accurate measurement

  1. Accurate thickness measurement of graphene

    Science.gov (United States)

    Shearer, Cameron J.; Slattery, Ashley D.; Stapleton, Andrew J.; Shapter, Joseph G.; Gibson, Christopher T.

    2016-03-01

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1-1.3 nm to 0.1-0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials.

  2. Accurate thickness measurement of graphene.

    Science.gov (United States)

    Shearer, Cameron J; Slattery, Ashley D; Stapleton, Andrew J; Shapter, Joseph G; Gibson, Christopher T

    2016-03-29

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1-1.3 nm to 0.1-0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials.

  3. 38 CFR 4.46 - Accurate measurement.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  4. Mangled extremity severity score: an accurate guide to treatment of the severely injured upper extremity.

    Science.gov (United States)

    Slauterbeck, J R; Britton, C; Moneim, M S; Clevenger, F W

    1994-08-01

    The mangled extremity severity score (MESS) is a scoring system that can be applied to mangled extremities and help one determine which mangled limbs will eventually come to amputation. The MESS is a graduated grading system based on skeletal and soft tissue injury, shock, ischemia, and age. The records of 37 patients having sustained 43 open fractures or mangled upper extremity injuries, seen and treated at the University of New Mexico's Regional Trauma Center between April 1987 and September 1990, have been reviewed. All nine extremity injuries with a MESS of greater than or equal to seven were amputated, and 34 of 34 with a MESS of less than seven were salvaged. Nine Grade IIIC and six mangled extremities were identified in our study. Five of these Grade IIIC and four of the mangled extremities with a MESS of greater than or equal to seven were amputated. All Grade IIIC or mangled extremities with a MESS of less than seven were salvaged. In conclusion, the MESS is an early and accurate predictor for identifying the extremities that may be best treated by amputation.

  5. Objective criteria accurately predict amputation following lower extremity trauma.

    Science.gov (United States)

    Johansen, K; Daines, M; Howey, T; Helfet, D; Hansen, S T

    1990-05-01

    MESS (Mangled Extremity Severity Score) is a simple rating scale for lower extremity trauma, based on skeletal/soft-tissue damage, limb ischemia, shock, and age. Retrospective analysis of severe lower extremity injuries in 25 trauma victims demonstrated a significant difference between MESS values for 17 limbs ultimately salvaged (mean, 4.88 +/- 0.27) and nine requiring amputation (mean, 9.11 +/- 0.51) (p less than 0.01). A prospective trial of MESS in lower extremity injuries managed at two trauma centers again demonstrated a significant difference between MESS values of 14 salvaged (mean, 4.00 +/- 0.28) and 12 doomed (mean, 8.83 +/- 0.53) limbs (p less than 0.01). In both the retrospective survey and the prospective trial, a MESS value greater than or equal to 7 predicted amputation with 100% accuracy. MESS may be useful in selecting trauma victims whose irretrievably injured lower extremities warrant primary amputation.

  6. Ionization Chamber Measures Extreme Ultraviolet

    Science.gov (United States)

    Carlson, Robert W.

    1987-01-01

    Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

  7. Accurate measurement of unsteady state fluid temperature

    Science.gov (United States)

    Jaremkiewicz, Magdalena

    2017-03-01

    In this paper, two accurate methods for determining the transient fluid temperature were presented. Measurements were conducted for boiling water since its temperature is known. At the beginning the thermometers are at the ambient temperature and next they are immediately immersed into saturated water. The measurements were carried out with two thermometers of different construction but with the same housing outer diameter equal to 15 mm. One of them is a K-type industrial thermometer widely available commercially. The temperature indicated by the thermometer was corrected considering the thermometers as the first or second order inertia devices. The new design of a thermometer was proposed and also used to measure the temperature of boiling water. Its characteristic feature is a cylinder-shaped housing with the sheath thermocouple located in its center. The temperature of the fluid was determined based on measurements taken in the axis of the solid cylindrical element (housing) using the inverse space marching method. Measurements of the transient temperature of the air flowing through the wind tunnel using the same thermometers were also carried out. The proposed measurement technique provides more accurate results compared with measurements using industrial thermometers in conjunction with simple temperature correction using the inertial thermometer model of the first or second order. By comparing the results, it was demonstrated that the new thermometer allows obtaining the fluid temperature much faster and with higher accuracy in comparison to the industrial thermometer. Accurate measurements of the fast changing fluid temperature are possible due to the low inertia thermometer and fast space marching method applied for solving the inverse heat conduction problem.

  8. Apparatus for accurately measuring high temperatures

    Science.gov (United States)

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  9. Fast and accurate exhaled breath ammonia measurement.

    Science.gov (United States)

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A; Risby, Terence H

    2014-06-11

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

  10. New algorithm for extreme temperature measurements

    NARCIS (Netherlands)

    Damean, N.

    2000-01-01

    A new algorithm for measurement of extreme temperature is presented. This algorithm reduces the measurement of the unknown temperature to the solving of an optimal control problem, using a numerical computer. Based on this method, a new device for extreme temperature measurements is projected. It co

  11. 3D stereophotogrammetry in upper-extremity lymphedema: An accurate diagnostic method

    NARCIS (Netherlands)

    Hameeteman, M.; Verhulst, A.C.; Vreeken, R.D.; Maal, T.J.; Ulrich, D.J.

    2016-01-01

    BACKGROUND: Upper-extremity lymphedema is a frequent complication in patients treated for breast cancer. Current diagnostic methods for the upper-extremity volume measurements are cumbersome or time consuming. The purpose of this study was to assess the validity and reliability of three-dimensional

  12. 3D stereophotogrammetry in upper-extremity lymphedema: An accurate diagnostic method

    NARCIS (Netherlands)

    Hameeteman, M.; Verhulst, A.C.; Vreeken, R.D.; Maal, T.J.; Ulrich, D.J.

    2016-01-01

    BACKGROUND: Upper-extremity lymphedema is a frequent complication in patients treated for breast cancer. Current diagnostic methods for the upper-extremity volume measurements are cumbersome or time consuming. The purpose of this study was to assess the validity and reliability of three-dimensional

  13. Fast and Accurate Exhaled Breath Ammonia Measurement

    OpenAIRE

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A.; Risby, Terence H.

    2014-01-01

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Toge...

  14. Extreme ultraviolet spectral irradiance measurements since 1946

    Science.gov (United States)

    Schmidtke, G.

    2015-03-01

    In the physics of the upper atmosphere the solar extreme ultraviolet (EUV) radiation plays a dominant role controlling most of the thermospheric/ionospheric (T/I) processes. Since this part of the solar spectrum is absorbed in the thermosphere, platforms to measure the EUV fluxes became only available with the development of rockets reaching altitude levels exceeding 80 km. With the availability of V2 rockets used in space research, recording of EUV spectra started in 1946 using photographic films. The development of pointing devices to accurately orient the spectrographs toward the sun initiated intense activities in solar-terrestrial research. The application of photoelectric recording technology enabled the scientists placing EUV spectrometers aboard satellites observing qualitatively strong variability of the solar EUV irradiance on short-, medium-, and long-term scales. However, as more measurements were performed more radiometric EUV data diverged due to the inherent degradation of the EUV instruments with time. Also, continuous recording of the EUV energy input to the T/I system was not achieved. It is only at the end of the last century that there was progress made in solving the serious problem of degradation enabling to monitore solar EUV fluxes with sufficient radiometric accuracy. The data sets available allow composing the data available to the first set of EUV data covering a period of 11 years for the first time. Based on the sophisticated instrumentation verified in space, future EUV measurements of the solar spectral irradiance (SSI) are promising accuracy levels of about 5% and less. With added low-cost equipment, real-time measurements will allow providing data needed in ionospheric modeling, e.g., for correcting propagation delays of navigation signals from space to earth. Adding EUV airglow and auroral emission monitoring by airglow cameras, the impact of space weather on the terrestrial T/I system can be studied with a spectral terrestrial

  15. Accurate particle position measurement from images

    CERN Document Server

    Feng, Yan; Liu, Bin; 10.1063/1.2735920

    2011-01-01

    The moment method is an image analysis technique for sub-pixel estimation of particle positions. The total error in the calculated particle position includes effects of pixel locking and random noise in each pixel. Pixel locking, also known as peak locking, is an artifact where calculated particle positions are concentrated at certain locations relative to pixel edges. We report simulations to gain an understanding of the sources of error and their dependence on parameters the experimenter can control. We suggest an algorithm, and we find optimal parameters an experimenter can use to minimize total error and pixel locking. Simulating a dusty plasma experiment, we find that a sub-pixel accuracy of 0.017 pixel or better can be attained. These results are also useful for improving particle position measurement and particle tracking velocimetry (PTV) using video microscopy, in fields including colloids, biology, and fluid mechanics.

  16. The non-compressibility ratio for accurate diagnosis of lower extremity deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Caecilia Marliana

    2014-08-01

    Full Text Available Background Accurate identification of patients with deep vein thrombosis (DVT is critical, as untreated cases can be fatal. It is well established that the specificity of the clinical signs and symptoms of DVT is low. Therefore, clinicians rely on additional tests to make this diagnosis. There are three modalities for DVT diagnosis; clinical scoring, laboratory investigations, and radiology. The objective of this study was to determine the correlation of plasma D-dimer concentration with the ultrasonographic non-compressibility ratio in patients with DVT in the lower extremities. Methods This research was a cross-sectional observational study. The sample comprised 25 subjects over 30 years of age with clinically diagnosed DVT in the lower extremities. In all subjects, D-dimer determination using latex enhanced turbidimetric test was performed, as well as ultrasonographic non-compressibility ratio assessment of the lower extremities. Data were analyzed using Pearson’s correlation at significance level of 0.05. Results Mean plasma D-dimer concentration was 2953.00 ± 2054.44 mg/L. The highest mean non-compressibility ratio (59.96 ± 35.98% was found in the superficial femoral vein and the lowest mean non-compressibility ratio (42.68 ± 33.71% in the common femoral vein. There was a moderately significant correlation between plasma D-dimer level and non-compressibility ratio in the popliteal vein (r=0.582; p=0.037. In the other veins of the lower extremities, no significant correlation was found. Conclusion The sonographic non-compressibility ratio is an objective test for quick and accurate diagnosis of lower extremity DVT and for evaluation of DVT severity.

  17. Extreme Value distribution for singular measures

    CERN Document Server

    Faranda, Davide; Turchetti, Giorgio; Vaienti, Sandro

    2011-01-01

    In this paper we perform an analytical and numerical study of Extreme Value distributions in discrete dynamical systems that have a singular measure. Using the block maxima approach described in Faranda et al. [2011] we show that, numerically, the Extreme Value distribution for these maps can be associated to the Generalised Extreme Value family where the parameters scale with the information dimension. The numerical analysis are performed on a few low dimensional maps. For the middle third Cantor set and the Sierpinskij triangle obtained using Iterated Function Systems, experimental parameters show a very good agreement with the theoretical values. For strange attractors like Lozi and H\\`enon maps a slower convergence to the Generalised Extreme Value distribution is observed. Even in presence of large statistics the observed convergence is slower if compared with the maps which have an absolute continuous invariant measure. Nevertheless and within the uncertainty computed range, the results are in good agree...

  18. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    Science.gov (United States)

    1999-06-01

    estimate of the age of the universe. In order to do this, you need an unambiguous, absolute distance to another galaxy. We are pleased that the NSF's VLBA has for the first time determined such a distance, and thus provided the calibration standard astronomers have always sought in their quest for accurate distances beyond the Milky Way," said Morris Aizenman, Executive Officer of the National Science Foundation's (NSF) Division of Astronomical Sciences. "For astronomers, this measurement is the golden meter stick in the glass case," Aizenman added. The international team of astronomers used the VLBA to measure directly the motion of gas orbiting what is generally agreed to be a supermassive black hole at the heart of NGC 4258. The orbiting gas forms a warped disk, nearly two light-years in diameter, surrounding the black hole. The gas in the disk includes water vapor, which, in parts of the disk, acts as a natural amplifier of microwave radio emission. The regions that amplify radio emission are called masers, and work in a manner similar to the way a laser amplifies light emission. Determining the distance to NGC 4258 required measuring motions of extremely small shifts in position of these masers as they rotate around the black hole. This is equivalent to measuring an angle one ten-thousandth the width of a human hair held at arm's length. "The VLBA is the only instrument in the world that could do this," said Moran. "This work is the culmination of a 20-year effort at the Harvard Smithsonian Center for Astrophysics to measure distances to cosmic masers," said Irwin Shapiro, Director of that institution. Collection of the data for the NGC 4258 project was begun in 1994 and was part of Herrnstein's Ph.D dissertation at Harvard University. Previous observations with the VLBA allowed the scientists to measure the speed at which the gas is orbiting the black hole, some 39 million times more massive than the Sun. They did this by observing the amount of change in the

  19. Accurate Fiber Length Measurement Using Time-of-Flight Technique

    Science.gov (United States)

    Terra, Osama; Hussein, Hatem

    2016-06-01

    Fiber artifacts of very well-measured length are required for the calibration of optical time domain reflectometers (OTDR). In this paper accurate length measurement of different fiber lengths using the time-of-flight technique is performed. A setup is proposed to measure accurately lengths from 1 to 40 km at 1,550 and 1,310 nm using high-speed electro-optic modulator and photodetector. This setup offers traceability to the SI unit of time, the second (and hence to meter by definition), by locking the time interval counter to the Global Positioning System (GPS)-disciplined quartz oscillator. Additionally, the length of a recirculating loop artifact is measured and compared with the measurement made for the same fiber by the National Physical Laboratory of United Kingdom (NPL). Finally, a method is proposed to relatively correct the fiber refractive index to allow accurate fiber length measurement.

  20. Accurate Insertion Loss Measurements of the Juno Patch Array Antennas

    Science.gov (United States)

    Chamberlain, Neil; Chen, Jacqueline; Hodges, Richard; Demas, John

    2010-01-01

    This paper describes two independent methods for estimating the insertion loss of patch array antennas that were developed for the Juno Microwave Radiometer instrument. One method is based principally on pattern measurements while the other method is based solely on network analyzer measurements. The methods are accurate to within 0.1 dB for the measured antennas and show good agreement (to within 0.1dB) of separate radiometric measurements.

  1. Highly Accurate Measurement of the Electron Orbital Magnetic Moment

    CERN Document Server

    Awobode, A M

    2015-01-01

    We propose to accurately determine the orbital magnetic moment of the electron by measuring, in a Magneto-Optical or Ion trap, the ratio of the Lande g-factors in two atomic states. From the measurement of (gJ1/gJ2), the quantity A, which depends on the corrections to the electron g-factors can be extracted, if the states are LS coupled. Given that highly accurate values of the correction to the spin g-factor are currently available, accurate values of the correction to the orbital g-factor may also be determined. At present, (-1.8 +/- 0.4) x 10-4 has been determined as a correction to the electron orbital g-factor, by using earlier measurements of the ratio gJ1/gJ2, made on the Indium 2P1/2 and 2P3/2 states.

  2. A novel simple and accurate flatness measurement method

    CERN Document Server

    Thang, H L

    2011-01-01

    Flatness measurement of a surface plate is an intensive and old research topic. However ISO definition related and other measurement methods seem uneasy in measuring and/ or complicated in data analysis. Especially in reality, the mentioned methods don't take a clear and straightforward care on the inclining angle which is always included in any given flatness measurement. In this report a novel simple and accurate flatness measurement method was introduced to overcome this prevailing feature in the available methods. The mathematical modeling for this method was also presented making the underlying nature of the method transparent. The applying examples show consistent results.

  3. A Simple and Accurate Method for Measuring Enzyme Activity.

    Science.gov (United States)

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  4. A Simple and Accurate Method for Measuring Enzyme Activity.

    Science.gov (United States)

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  5. Accurate measurement of streamwise vortices using dual-plane PIV

    Science.gov (United States)

    Waldman, Rye M.; Breuer, Kenneth S.

    2012-11-01

    Low Reynolds number aerodynamic experiments with flapping animals (such as bats and small birds) are of particular interest due to their application to micro air vehicles which operate in a similar parameter space. Previous PIV wake measurements described the structures left by bats and birds and provided insight into the time history of their aerodynamic force generation; however, these studies have faced difficulty drawing quantitative conclusions based on said measurements. The highly three-dimensional and unsteady nature of the flows associated with flapping flight are major challenges for accurate measurements. The challenge of animal flight measurements is finding small flow features in a large field of view at high speed with limited laser energy and camera resolution. Cross-stream measurement is further complicated by the predominately out-of-plane flow that requires thick laser sheets and short inter-frame times, which increase noise and measurement uncertainty. Choosing appropriate experimental parameters requires compromise between the spatial and temporal resolution and the dynamic range of the measurement. To explore these challenges, we do a case study on the wake of a fixed wing. The fixed model simplifies the experiment and allows direct measurements of the aerodynamic forces via load cell. We present a detailed analysis of the wake measurements, discuss the criteria for making accurate measurements, and present a solution for making quantitative aerodynamic load measurements behind free-flyers.

  6. Accurate speed and slip measurement of induction motors

    Energy Technology Data Exchange (ETDEWEB)

    Ho, S.Y.S.; Langman, R. [Tasmania Univ., Hobart, TAS (Australia)

    1996-03-01

    Two alternative hardware circuits, for the accurate measurement of low slip in cage induction motors, are discussed. Both circuits compare the periods of the fundamental of the supply frequency and pulses from a shaft-connected toothed-wheel. The better of the two achieves accuracy to 0.5 percent of slip over the range 0.1 to 0.005, or better than 0.001 percent of speed over the range. This method is considered useful for slip measurement of motors supplied by either constant frequency mains of variable speed controllers with PMW waveforms. It is demonstrated that accurate slip measurement supports the conclusions of work previously done on the detection of broken rotor bars. (author). 1 tab., 6 figs., 13 refs.

  7. Accurate measurement of ultrasonic velocity by eliminating the diffraction effect

    Institute of Scientific and Technical Information of China (English)

    WEI Tingcun

    2003-01-01

    The accurate measurement method of ultrasonic velocity by the pulse interferencemethod with eliminating the diffraction effect has been investigated in VHF range experimen-tally. Two silicate glasses were taken as the specimens, their frequency dependences of longitu-dinal velocities were measured in the frequency range 50-350 MHz, and the phase advances ofultrasonic signals caused by diffraction effect were calculated using A. O. Williams' theoreticalexpression. For the frequency dependences of longitudinal velocities, the measurement resultswere in good agreement with the simulation ones in which the phase advances were included.It has been shown that the velocity error due to diffraction effect can be corrected very well bythis method.

  8. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    Directory of Open Access Journals (Sweden)

    Mark Shortis

    2015-12-01

    Full Text Available Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  9. Calibration Techniques for Accurate Measurements by Underwater Camera Systems.

    Science.gov (United States)

    Shortis, Mark

    2015-12-07

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  10. Accurate measurement of the helical twisting power of chiral dopants

    Science.gov (United States)

    Kosa, Tamas; Bodnar, Volodymyr; Taheri, Bahman; Palffy-Muhoray, Peter

    2002-03-01

    We propose a method for the accurate determination of the helical twisting power (HTP) of chiral dopants. In the usual Cano-wedge method, the wedge angle is determined from the far-field separation of laser beams reflected from the windows of the test cell. Here we propose to use an optical fiber based spectrometer to accurately measure the cell thickness. Knowing the cell thickness at the positions of the disclination lines allows determination of the HTP. We show that this extension of the Cano-wedge method greatly increases the accuracy with which the HTP is determined. We show the usefulness of this method by determining the HTP of ZLI811 in a variety of hosts with negative dielectric anisotropy.

  11. Methods for Accurate Free Flight Measurement of Drag Coefficients

    CERN Document Server

    Courtney, Elya; Courtney, Michael

    2015-01-01

    This paper describes experimental methods for free flight measurement of drag coefficients to an accuracy of approximately 1%. There are two main methods of determining free flight drag coefficients, or equivalent ballistic coefficients: 1) measuring near and far velocities over a known distance and 2) measuring a near velocity and time of flight over a known distance. Atmospheric conditions must also be known and nearly constant over the flight path. A number of tradeoffs are important when designing experiments to accurately determine drag coefficients. The flight distance must be large enough so that the projectile's loss of velocity is significant compared with its initial velocity and much larger than the uncertainty in the near and/or far velocity measurements. On the other hand, since drag coefficients and ballistic coefficients both depend on velocity, the change in velocity over the flight path should be small enough that the average drag coefficient over the path (which is what is really determined)...

  12. Accurate skin dose measurements using radiochromic film in clinical applications.

    Science.gov (United States)

    Devic, S; Seuntjens, J; Abdel-Rahman, W; Evans, M; Olivares, M; Podgorsak, E B; Vuong, Té; Soares, Christopher G

    2006-04-01

    Megavoltage x-ray beams exhibit the well-known phenomena of dose buildup within the first few millimeters of the incident phantom surface, or the skin. Results of the surface dose measurements, however, depend vastly on the measurement technique employed. Our goal in this study was to determine a correction procedure in order to obtain an accurate skin dose estimate at the clinically relevant depth based on radiochromic film measurements. To illustrate this correction, we have used as a reference point a depth of 70 micron. We used the new GAFCHROMIC dosimetry films (HS, XR-T, and EBT) that have effective points of measurement at depths slightly larger than 70 micron. In addition to films, we also used an Attix parallel-plate chamber and a home-built extrapolation chamber to cover tissue-equivalent depths in the range from 4 micron to 1 mm of water-equivalent depth. Our measurements suggest that within the first millimeter of the skin region, the PDD for a 6 MV photon beam and field size of 10 x 10 cm2 increases from 14% to 43%. For the three GAFCHROMIC dosimetry film models, the 6 MV beam entrance skin dose measurement corrections due to their effective point of measurement are as follows: 15% for the EBT, 15% for the HS, and 16% for the XR-T model GAFCHROMIC films. The correction factors for the exit skin dose due to the build-down region are negligible. There is a small field size dependence for the entrance skin dose correction factor when using the EBT GAFCHROMIC film model. Finally, a procedure that uses EBT model GAFCHROMIC film for an accurate measurement of the skin dose in a parallel-opposed pair 6 MV photon beam arrangement is described.

  13. An Analytic Method for Measuring Accurate Fundamental Frequency Components

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Soon Ryul; Park Jong Keun [Seoul National University, Seoul(Korea); Kang, Sang Hee [Myongji University, Seoul (Korea)

    2002-04-01

    This paper proposes an analytic method for measuring the accurate fundamental frequency component of a fault current signal distorted with a DC-offset, a characteristic frequency component, and harmonics. The proposed algorithm is composed of four stages: sine filer, linear filter, Prony's method, and measurement. The sine filter and the linear filter eliminate harmonics and the fundamental frequency component, respectively. Then Prony's method is used to estimate the parameters of the DC-offset and the characteristic frequency component. Finally, the fundamental frequency component is measured by compensating the sine-filtered signal with the estimated parameters. The performance evaluation of the proposed method is presented for a-phase to ground faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault current signals under different fault locations and fault inception angles. It is shown that the analytic method accurately measures the fundamental frequency component regardless of the characteristic frequency component as well as the DC-offset.(author). 19 refs., 4 figs., 4 tabs.

  14. Accurate Runout Measurement for HDD Spinning Motors and Disks

    Science.gov (United States)

    Jiang, Quan; Bi, Chao; Lin, Song

    As hard disk drive (HDD) areal density increases, its track width becomes smaller and smaller and so is non-repeatable runout. HDD industry needs more accurate and better resolution runout measurements of spinning spindle motors and media platters in both axial and radial directions. This paper introduces a new system how to precisely measure the runout of HDD spinning disks and motors through synchronously acquiring the rotor position signal and the displacements in axial or radial directions. In order to minimize the synchronizing error between the rotor position and the displacement signal, a high resolution counter is adopted instead of the conventional phase-lock loop method. With Laser Doppler Vibrometer and proper signal processing, the proposed runout system can precisely measure the runout of the HDD spinning disks and motors with 1 nm resolution and 0.2% accuracy with a proper sampling rate. It can provide an effective and accurate means to measure the runout of high areal density HDDs, in particular the next generation HDDs, such as, pattern media HDDs and HAMR HDDs.

  15. Accurate measurement method for tube's endpoints based on machine vision

    Science.gov (United States)

    Liu, Shaoli; Jin, Peng; Liu, Jianhua; Wang, Xiao; Sun, Peng

    2017-01-01

    Tubes are used widely in aerospace vehicles, and their accurate assembly can directly affect the assembling reliability and the quality of products. It is important to measure the processed tube's endpoints and then fix any geometric errors correspondingly. However, the traditional tube inspection method is time-consuming and complex operations. Therefore, a new measurement method for a tube's endpoints based on machine vision is proposed. First, reflected light on tube's surface can be removed by using photometric linearization. Then, based on the optimization model for the tube's endpoint measurements and the principle of stereo matching, the global coordinates and the relative distance of the tube's endpoint are obtained. To confirm the feasibility, 11 tubes are processed to remove the reflected light and then the endpoint's positions of tubes are measured. The experiment results show that the measurement repeatability accuracy is 0.167 mm, and the absolute accuracy is 0.328 mm. The measurement takes less than 1 min. The proposed method based on machine vision can measure the tube's endpoints without any surface treatment or any tools and can realize on line measurement.

  16. Accurate Measurement Method for Tube's Endpoints Based on Machine Vision

    Institute of Scientific and Technical Information of China (English)

    LIU Shaoli; JIN Peng; LIU Jianhua; WANG Xiao; SUN Peng

    2017-01-01

    Tubes are used widely in aerospace vehicles,and their accurate assembly can directly affect the assembling reliability and the quality of products.It is important to measure the processed tube's endpoints and then fix any geometric errors correspondingly.However,the traditional tube inspection method is time-consuming and complex operations.Therefore,a new measurement method for a tube's endpoints based on machine vision is proposed.First,reflected light on tube's surface can be removed by using photometric linearization.Then,based on the optimization model for the tube's endpoint measurements and the principle of stereo matching,the global coordinates and the relative distance of the tube's endpoint are obtained.To confirm the feasibility,11 tubes are processed to remove the reflected light and then the endpoint's positions of tubes are measured.The experiment results show that the measurement repeatability accuracy is 0.167 mm,and the absolute accuracy is 0.328 mm.The measurement takes less than 1 min.The proposed method based on machine vision can measure the tube's endpoints without any surface treatment or any tools and can realize on line measurement.

  17. Accurate measurement method for tube's endpoints based on machine vision

    Science.gov (United States)

    Liu, Shaoli; Jin, Peng; Liu, Jianhua; Wang, Xiao; Sun, Peng

    2016-08-01

    Tubes are used widely in aerospace vehicles, and their accurate assembly can directly affect the assembling reliability and the quality of products. It is important to measure the processed tube's endpoints and then fix any geometric errors correspondingly. However, the traditional tube inspection method is time-consuming and complex operations. Therefore, a new measurement method for a tube's endpoints based on machine vision is proposed. First, reflected light on tube's surface can be removed by using photometric linearization. Then, based on the optimization model for the tube's endpoint measurements and the principle of stereo matching, the global coordinates and the relative distance of the tube's endpoint are obtained. To confirm the feasibility, 11 tubes are processed to remove the reflected light and then the endpoint's positions of tubes are measured. The experiment results show that the measurement repeatability accuracy is 0.167 mm, and the absolute accuracy is 0.328 mm. The measurement takes less than 1 min. The proposed method based on machine vision can measure the tube's endpoints without any surface treatment or any tools and can realize on line measurement.

  18. Accurate mass measurements on neutron-deficient krypton isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, D. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany)]. E-mail: rodriguez@lpccaen.in2p3.fr; Audi, G. [CSNSM-IN2P3-CNRS, 91405 Orsay-Campus(France); Aystoe, J. [University of Jyvaeskylae, Department of Physics, P.O. Box 35, 40351 Jyvaeskylae (Finland); Beck, D. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Blaum, K. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Institute of Physics, University of Mainz, Staudingerweg 7, 55128 Mainz (Germany); Bollen, G. [NSCL, Michigan State University, East Lansing, MI 48824-1321 (United States); Herfurth, F. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Jokinen, A. [University of Jyvaeskylae, Department of Physics, P.O. Box 35, 40351 Jyvaeskylae (Finland); Kellerbauer, A. [CERN, Division EP, 1211 Geneva 23 (Switzerland); Kluge, H.-J. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); University of Heidelberg, 69120 Heidelberg (Germany); Kolhinen, V.S. [University of Jyvaeskylae, Department of Physics, P.O. Box 35, 40351 Jyvaeskylae (Finland); Oinonen, M. [Helsinki Institute of Physics, P.O. Box 64, 00014 University of Helsinki (Finland); Sauvan, E. [Institute of Physics, University of Mainz, Staudingerweg 7, 55128 Mainz (Germany); Schwarz, S. [NSCL, Michigan State University, East Lansing, MI 48824-1321 (United States)

    2006-04-17

    The masses of {sup 72-78,80,82,86}Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for {sup 72-75}Kr outweighed previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  19. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D; Äystö, J; Beck, D

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  20. Technological Basis and Scientific Returns for Absolutely Accurate Measurements

    Science.gov (United States)

    Dykema, J. A.; Anderson, J.

    2011-12-01

    The 2006 NRC Decadal Survey fostered a new appreciation for societal objectives as a driving motivation for Earth science. Many high-priority societal objectives are dependent on predictions of weather and climate. These predictions are based on numerical models, which derive from approximate representations of well-founded physics and chemistry on space and timescales appropriate to global and regional prediction. These laws of chemistry and physics in turn have a well-defined quantitative relationship with physical measurement units, provided these measurement units are linked to international measurement standards that are the foundation of contemporary measurement science and standards for engineering and commerce. Without this linkage, measurements have an ambiguous relationship to scientific principles that introduces avoidable uncertainty in analyses, predictions, and improved understanding of the Earth system. Since the improvement of climate and weather prediction is fundamentally dependent on the improvement of the representation of physical processes, measurement systems that reduce the ambiguity between physical truth and observations represent an essential component of a national strategy for understanding and living with the Earth system. This paper examines the technological basis and potential science returns of sensors that make measurements that are quantitatively tied on-orbit to international measurement standards, and thus testable to systematic errors. This measurement strategy provides several distinct benefits. First, because of the quantitative relationship between these international measurement standards and fundamental physical constants, measurements of this type accurately capture the true physical and chemical behavior of the climate system and are not subject to adjustment due to excluded measurement physics or instrumental artifacts. In addition, such measurements can be reproduced by scientists anywhere in the world, at any time

  1. Novel dispersion tolerant interferometry method for accurate measurements of displacement

    Science.gov (United States)

    Bradu, Adrian; Maria, Michael; Leick, Lasse; Podoleanu, Adrian G.

    2015-05-01

    We demonstrate that the recently proposed master-slave interferometry method is able to provide true dispersion free depth profiles in a spectrometer-based set-up that can be used for accurate displacement measurements in sensing and optical coherence tomography. The proposed technique is based on correlating the channelled spectra produced by the linear camera in the spectrometer with previously recorded masks. As such technique is not based on Fourier transformations (FT), it does not require any resampling of data and is immune to any amounts of dispersion left unbalanced in the system. In order to prove the tolerance of technique to dispersion, different lengths of optical fiber are used in the interferometer to introduce dispersion and it is demonstrated that neither the sensitivity profile versus optical path difference (OPD) nor the depth resolution are affected. In opposition, it is shown that the classical FT based methods using calibrated data provide less accurate optical path length measurements and exhibit a quicker decays of sensitivity with OPD.

  2. Accurate and precise zinc isotope ratio measurements in urban aerosols.

    Science.gov (United States)

    Gioia, Simone; Weiss, Dominik; Coles, Barry; Arnold, Tim; Babinski, Marly

    2008-12-15

    We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of delta(66)Zn determinations in aerosols is around 0.05 per thousand per atomic mass unit. The method was tested on aerosols collected in Sao Paulo City, Brazil. The measurements reveal significant variations in delta(66)Zn(Imperial) ranging between -0.96 and -0.37 per thousand in coarse and between -1.04 and 0.02 per thousand in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source. We present further delta(66)Zn(Imperial) data for the standard reference material NIST SRM 2783 (delta(66)Zn(Imperial) = 0.26 +/- 0.10 per thousand).

  3. Accurate Sound Velocity Measurement in Ocean Near-Surface Layer

    Science.gov (United States)

    Lizarralde, D.; Xu, B. L.

    2015-12-01

    Accurate sound velocity measurement is essential in oceanography because sound is the only wave that can propagate in sea water. Due to its measuring difficulties, sound velocity is often not measured directly but instead calculated from water temperature, salinity, and depth, which are much easier to obtain. This research develops a new method to directly measure the sound velocity in the ocean's near-surface layer using multi-channel seismic (MCS) hydrophones. This system consists of a device to make a sound pulse and a long cable with hundreds of hydrophones to record the sound. The distance between the source and each receiver is the offset. The time it takes the pulse to arrive to each receiver is the travel time.The errors of measuring offset and travel time will affect the accuracy of sound velocity if we calculated with just one offset and one travel time. However, by analyzing the direct arrival signal from hundreds of receivers, the velocity can be determined as the slope of a straight line in the travel time-offset graph. The errors in distance and time measurement result in only an up or down shift of the line and do not affect the slope. This research uses MCS data of survey MGL1408 obtained from the Marine Geoscience Data System and processed with Seismic Unix. The sound velocity can be directly measured to an accuracy of less than 1m/s. The included graph shows the directly measured velocity verses the calculated velocity along 100km across the Mid-Atlantic continental margin. The directly measured velocity shows a good coherence to the velocity computed from temperature and salinity. In addition, the fine variations in the sound velocity can be observed, which is hardly seen from the calculated velocity. Using this methodology, both large area acquisition and fine resolution can be achieved. This directly measured sound velocity will be a new and powerful tool in oceanography.

  4. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  5. Measuring extremal dependencies in web graphs

    NARCIS (Netherlands)

    Volkovich, Y.; Litvak, Nelli; Zwart, B.

    We analyze dependencies in power law graph data (Web sample, Wikipedia sample and a preferential attachment graph) using statistical inference for multivariate regular variation. The well developed theory of regular variation is widely applied in extreme value theory, telecommunications and

  6. Accurate measurement of RF exposure from emerging wireless communication systems

    Science.gov (United States)

    Letertre, Thierry; Monebhurrun, Vikass; Toffano, Zeno

    2013-04-01

    Isotropic broadband probes or spectrum analyzers (SAs) may be used for the measurement of rapidly varying electromagnetic fields generated by emerging wireless communication systems. In this paper this problematic is investigated by comparing the responses measured by two different isotropic broadband probes typically used to perform electric field (E-field) evaluations. The broadband probes are submitted to signals with variable duty cycles (DC) and crest factors (CF) either with or without Orthogonal Frequency Division Multiplexing (OFDM) modulation but with the same root-mean-square (RMS) power. The two probes do not provide accurate enough results for deterministic signals such as Worldwide Interoperability for Microwave Access (WIMAX) or Long Term Evolution (LTE) as well as for non-deterministic signals such as Wireless Fidelity (WiFi). The legacy measurement protocols should be adapted to cope for the emerging wireless communication technologies based on the OFDM modulation scheme. This is not easily achieved except when the statistics of the RF emission are well known. In this case the measurement errors are shown to be systematic and a correction factor or calibration can be applied to obtain a good approximation of the total RMS power.

  7. Accurate measurement of streamwise vortices in low speed aerodynamic flows

    Science.gov (United States)

    Waldman, Rye M.; Kudo, Jun; Breuer, Kenneth S.

    2010-11-01

    Low Reynolds number experiments with flapping animals (such as bats and small birds) are of current interest in understanding biological flight mechanics, and due to their application to Micro Air Vehicles (MAVs) which operate in a similar parameter space. Previous PIV wake measurements have described the structures left by bats and birds, and provided insight to the time history of their aerodynamic force generation; however, these studies have faced difficulty drawing quantitative conclusions due to significant experimental challenges associated with the highly three-dimensional and unsteady nature of the flows, and the low wake velocities associated with lifting bodies that only weigh a few grams. This requires the high-speed resolution of small flow features in a large field of view using limited laser energy and finite camera resolution. Cross-stream measurements are further complicated by the high out-of-plane flow which requires thick laser sheets and short interframe times. To quantify and address these challenges we present data from a model study on the wake behind a fixed wing at conditions comparable to those found in biological flight. We present a detailed analysis of the PIV wake measurements, discuss the criteria necessary for accurate measurements, and present a new dual-plane PIV configuration to resolve these issues.

  8. Accurate mass measurements of very short-lived nuclei

    CERN Document Server

    Herfurth, F; Ames, F; Audi, G; Beck, D; Blaum, K; Bollen, G; Engels, O; Kluge, H J; Lunney, M D; Moores, R B; Oinonen, M; Sauvan, E; Bolle, C A; Scheidenberger, C; Schwarz, S; Sikler, G; Weber, C

    2002-01-01

    Mass measurements of /sup 34/Ar, /sup 73-78/Kr, and /sup 74,76/Rb were performed with the Penning-trap mass spectrometer ISOLTRAP. Very accurate Q/sub EC/-values are needed for the investigations of the F /sub t/-value of 0/sup +/ to 0/sup +/ nuclear beta -decays used to test the standard model predictions for weak interactions. The necessary accuracy on the Q/sub EC/-value requires the mass of mother and daughter nuclei to be measured with delta m/mmeasured nuclides presented here this has been reached. The /sup 34/Ar mass has been measured with a relative accuracy of 1.1.10/sup -8/. The Q/sub EC/-value of the /sup 34/Ar 0 /sup +/ to 0/sup +/ decay can now he determined with an uncertainty of about 0.01%. Furthermore, /sup 74/Rb is the shortest-lived nuclide ever investigated in a Penning trap. (18 refs).

  9. Study of accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-12-01

    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  10. Accurate measure by weight of liquids in industry

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.R.

    1992-12-12

    This research's focus was to build a prototype of a computerized liquid dispensing system. This liquid metering system is based on the concept of altering the representative volume to account for temperature changes in the liquid to be dispensed. This is actualized by using a measuring tank and a temperature compensating displacement plunger. By constantly monitoring the temperature of the liquid, the plunger can be used to increase or decrease the specified volume to more accurately dispense liquid with a specified mass. In order to put the device being developed into proper engineering perspective, an extensive literature review was undertaken on all areas of industrial metering of liquids with an emphasis on gravimetric methods.

  11. Accurate measure by weight of liquids in industry. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.R.

    1992-12-12

    This research`s focus was to build a prototype of a computerized liquid dispensing system. This liquid metering system is based on the concept of altering the representative volume to account for temperature changes in the liquid to be dispensed. This is actualized by using a measuring tank and a temperature compensating displacement plunger. By constantly monitoring the temperature of the liquid, the plunger can be used to increase or decrease the specified volume to more accurately dispense liquid with a specified mass. In order to put the device being developed into proper engineering perspective, an extensive literature review was undertaken on all areas of industrial metering of liquids with an emphasis on gravimetric methods.

  12. Accurate measurement of liquid transport through nanoscale conduits

    Science.gov (United States)

    Alibakhshi, Mohammad Amin; Xie, Quan; Li, Yinxiao; Duan, Chuanhua

    2016-01-01

    Nanoscale liquid transport governs the behaviour of a wide range of nanofluidic systems, yet remains poorly characterized and understood due to the enormous hydraulic resistance associated with the nanoconfinement and the resulting minuscule flow rates in such systems. To overcome this problem, here we present a new measurement technique based on capillary flow and a novel hybrid nanochannel design and use it to measure water transport through single 2-D hydrophilic silica nanochannels with heights down to 7 nm. Our results show that silica nanochannels exhibit increased mass flow resistance compared to the classical hydrodynamics prediction. This difference increases with decreasing channel height and reaches 45% in the case of 7 nm nanochannels. This resistance increase is attributed to the formation of a 7-angstrom-thick stagnant hydration layer on the hydrophilic surfaces. By avoiding use of any pressure and flow sensors or any theoretical estimations the hybrid nanochannel scheme enables facile and precise flow measurement through single nanochannels, nanotubes, or nanoporous media and opens the prospect for accurate characterization of both hydrophilic and hydrophobic nanofluidic systems. PMID:27112404

  13. Accurate estimation of third-order moments from turbulence measurements

    Directory of Open Access Journals (Sweden)

    J. J. Podesta

    2009-02-01

    Full Text Available Politano and Pouquet's law, a generalization of Kolmogorov's four-fifths law to incompressible MHD, makes it possible to measure the energy cascade rate in incompressible MHD turbulence by means of third-order moments. In hydrodynamics, accurate measurement of third-order moments requires large amounts of data because the probability distributions of velocity-differences are nearly symmetric and the third-order moments are relatively small. Measurements of the energy cascade rate in solar wind turbulence have recently been performed for the first time, but without careful consideration of the accuracy or statistical uncertainty of the required third-order moments. This paper investigates the statistical convergence of third-order moments as a function of the sample size N. It is shown that the accuracy of the third-moment <(δ v||3> depends on the number of correlation lengths spanned by the data set and a method of estimating the statistical uncertainty of the third-moment is developed. The technique is illustrated using both wind tunnel data and solar wind data.

  14. Accurate multipixel phase measurement with classical-light interferometry

    Science.gov (United States)

    Singh, Mandeep; Khare, Kedar; Jha, Anand Kumar; Prabhakar, Shashi; Singh, R. P.

    2015-02-01

    We demonstrate accurate phase measurement from experimental low photon level interferograms using a constrained optimization method that takes into account the expected redundancy in the unknown phase function. This approach is shown to have significant noise advantage over traditional methods, such as balanced homodyning or phase shifting, that treat individual pixels in the interference data as independent of each other. Our interference experiments comparing the optimization method with the traditional phase-shifting method show that when the same photon resources are used, the optimization method provides phase recoveries with tighter error bars. In particular, rms phase error performance of the optimization method for low photon number data (10 photons per pixel) shows a >5 × noise gain over the phase-shifting method. In our experiments where a laser light source is used for illumination, the results imply phase measurement with an accuracy better than the conventional single-pixel-based shot-noise limit that assumes independent phases at individual pixels. The constrained optimization approach presented here is independent of the nature of the light source and may further enhance the accuracy of phase detection when a nonclassical-light source is used.

  15. Measuring extremal dependencies in web graphs

    NARCIS (Netherlands)

    Volkovich, Y.; Litvak, Nelli; Zwart, B.

    2008-01-01

    We analyze dependencies in power law graph data (Web sample, Wikipedia sample and a preferential attachment graph) using statistical inference for multivariate regular variation. The well developed theory of regular variation is widely applied in extreme value theory, telecommunications and mathemat

  16. Measurement of Fracture Geometry for Accurate Computation of Hydraulic Conductivity

    Science.gov (United States)

    Chae, B.; Ichikawa, Y.; Kim, Y.

    2003-12-01

    Fluid flow in rock mass is controlled by geometry of fractures which is mainly characterized by roughness, aperture and orientation. Fracture roughness and aperture was observed by a new confocal laser scanning microscope (CLSM; Olympus OLS1100). The wavelength of laser is 488nm, and the laser scanning is managed by a light polarization method using two galvano-meter scanner mirrors. The system improves resolution in the light axis (namely z) direction because of the confocal optics. The sampling is managed in a spacing 2.5 μ m along x and y directions. The highest measurement resolution of z direction is 0.05 μ m, which is the more accurate than other methods. For the roughness measurements, core specimens of coarse and fine grained granites were provided. Measurements were performed along three scan lines on each fracture surface. The measured data were represented as 2-D and 3-D digital images showing detailed features of roughness. Spectral analyses by the fast Fourier transform (FFT) were performed to characterize on the roughness data quantitatively and to identify influential frequency of roughness. The FFT results showed that components of low frequencies were dominant in the fracture roughness. This study also verifies that spectral analysis is a good approach to understand complicate characteristics of fracture roughness. For the aperture measurements, digital images of the aperture were acquired under applying five stages of uniaxial normal stresses. This method can characterize the response of aperture directly using the same specimen. Results of measurements show that reduction values of aperture are different at each part due to rough geometry of fracture walls. Laboratory permeability tests were also conducted to evaluate changes of hydraulic conductivities related to aperture variation due to different stress levels. The results showed non-uniform reduction of hydraulic conductivity under increase of the normal stress and different values of

  17. UAV multirotor platform for accurate turbulence measurements in the atmosphere

    Science.gov (United States)

    Carbajo Fuertes, Fernando; Wilhelm, Lionel; Sin, Kevin Edgar; Hofer, Matthias; Porté-Agel, Fernando

    2017-04-01

    One of the most challenging tasks in atmospheric field studies for wind energy is to obtain accurate turbulence measurements at any location inside the region of interest for a wind farm study. This volume would ideally include from several hundred meters to several kilometers around it and from ground height to the top of the boundary layer. An array of meteorological masts equipped with several sonic anemometers to cover all points of interest would be the best in terms of accuracy and data availability, but it is an obviously unfeasible solution. On the other hand, the evolution of wind LiDAR technology allows to measure at any point in space but unfortunately it involves two important limitations: the first one is the relatively low spatial and temporal resolution when compared to a sonic anemometer and the second one is the fact that the measurements are limited to the velocity component parallel to the laser beam (radial velocity). To overcome the aforementioned drawbacks, a UAV multirotor platform has been developed. It is based on a state-of-the-art octocopter with enough payload to carry laboratory-grade instruments for the measurement of time-resolved atmospheric pressure, three-component velocity vector and temperature; and enough autonomy to fly from 10 to 20 minutes, which is a standard averaging time in most atmospheric measurement applications. The UAV uses a gyroscope, an accelerometer, a GPS and an algorithm has been developed and integrated for the correction of any orientation and movement. This UAV platform opens many possibilities for the study of features that have been almost exclusively studied until now in wind tunnel such as wind turbine blade tip vortex characteristics, near-wake to far-wake transition, momentum entrainment from the higher part of the boundary layer in wind farms, etc. The validation of this new measurement technique has been performed against sonic anemometry in terms of wind speed and temperature time series as well as

  18. History and progress on accurate measurements of the Planck constant

    Science.gov (United States)

    Steiner, Richard

    2013-01-01

    The measurement of the Planck constant, h, is entering a new phase. The CODATA 2010 recommended value is 6.626 069 57 × 10-34 J s, but it has been a long road, and the trip is not over yet. Since its discovery as a fundamental physical constant to explain various effects in quantum theory, h has become especially important in defining standards for electrical measurements and soon, for mass determination. Measuring h in the International System of Units (SI) started as experimental attempts merely to prove its existence. Many decades passed while newer experiments measured physical effects that were the influence of h combined with other physical constants: elementary charge, e, and the Avogadro constant, NA. As experimental techniques improved, the precision of the value of h expanded. When the Josephson and quantum Hall theories led to new electronic devices, and a hundred year old experiment, the absolute ampere, was altered into a watt balance, h not only became vital in definitions for the volt and ohm units, but suddenly it could be measured directly and even more accurately. Finally, as measurement uncertainties now approach a few parts in 108 from the watt balance experiments and Avogadro determinations, its importance has been linked to a proposed redefinition of a kilogram unit of mass. The path to higher accuracy in measuring the value of h was not always an example of continuous progress. Since new measurements periodically led to changes in its accepted value and the corresponding SI units, it is helpful to see why there were bumps in the road and where the different branch lines of research joined in the effort. Recalling the bumps along this road will hopefully avoid their repetition in the upcoming SI redefinition debates. This paper begins with a brief history of the methods to measure a combination of fundamental constants, thus indirectly obtaining the Planck constant. The historical path is followed in the section describing how the improved

  19. Accurate MTF measurement in digital radiography using noise response

    Energy Technology Data Exchange (ETDEWEB)

    Kuhls-Gilcrist, Andrew; Jain, Amit; Bednarek, Daniel R.; Hoffmann, Kenneth R.; Rudin, Stephen [Toshiba Stroke Research Center, University at Buffalo, State University of New York, Biomedical Research Building, Room 445, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    .4%. Above 0.5 f{sub N}, differences increased to an average of 20%. Deviations of the experimental results largely followed the trend seen in the simulation results, suggesting that differences between the two methods could be explained as resulting from the inherent inaccuracies of the edge-response measurement technique used in this study. Aliasing of the correlated noise component was shown to have a minimal effect on the measured MTF for the three detectors studied. Systems with significant aliasing of the correlated noise component (e.g., a-Se based detectors) would likely require a more sophisticated fitting scheme to provide accurate results. Conclusions: Results indicate that the noise-response method, a simple technique, can be used to accurately measure the MTF of digital x-ray detectors, while alleviating the problems and inaccuracies associated with use of precision test objects, such as a slit or an edge.

  20. Accurate absolute measurement of trapped Cs atoms in a MOT

    Energy Technology Data Exchange (ETDEWEB)

    Talavera O, M.; Lopez R, M.; Carlos L, E. de [Division de Tiempo y Frecuencia, Centro Nacional de Metrologia, CENAM, km 4.5 Carretera a los Cues, El Marques, 76241 Queretaro (Mexico); Jimenez S, S. [Centro de Investigacion y Estudios Avanzados del lPN, Unidad Queretaro, Libramiento Norponiente No. 2000, Fracc. Real de Juriquilla, 76230 Queretaro (Mexico)

    2007-07-01

    A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrologia, CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration ({sigma}{sup +} - {sigma}{sup -}) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is l MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to 6 x 10{sup 7} Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%. (Author)

  1. Automatic classification and accurate size measurement of blank mask defects

    Science.gov (United States)

    Bhamidipati, Samir; Paninjath, Sankaranarayanan; Pereira, Mark; Buck, Peter

    2015-07-01

    complexity of defects encountered. The variety arises due to factors such as defect nature, size, shape and composition; and the optical phenomena occurring around the defect. This paper focuses on preliminary characterization results, in terms of classification and size estimation, obtained by Calibre MDPAutoClassify tool on a variety of mask blank defects. It primarily highlights the challenges faced in achieving the results with reference to the variety of defects observed on blank mask substrates and the underlying complexities which make accurate defect size measurement an important and challenging task.

  2. Critical Considerations for Accurate Soil CO2 Flux Measurement

    Science.gov (United States)

    Xu, L.; Furtaw, M.; Madsen, R.; Welles, J.; Demetriades-Shah, T.; Anderson, D.; Garcia, R.; McDermitt, D.

    2005-12-01

    Soil respiration is a significant component of the carbon balance for an ecosystem, but the environmental (soil moisture, rain event, temperature etc.) and biological (photosynthesis, LAI etc.) factors that contribute to soil respiration remain poorly understood. This limits our ability to understand the carbon budget at the ecosystem level making it difficult to predict the impacts of climate change. Two important reasons for this poor understanding have been the difficulty in making accurate soil respiration measurements and the lack of continuous and long-term soil respiration data at sufficiently fine temporal and spatial scales. To meet these needs, we have developed a new automated multiplexing system, the LI-8100M, for obtaining reliable soil CO2 flux data at high spatial and temporal resolution. The system has the capability to continuously measure the soil CO2 flux at up to 16 locations. Soil CO2 flux is driven primarily by the CO2 diffusion gradient across the soil surface. Ideally, the flux measurement should be made without affecting the diffusion gradient and without having any chamber-induced pressure perturbation. In a closed-chamber system the slope of dCO2/dt is required to compute the flux. To obtain the slope of dCO2/dt, the chamber CO2 concentration must be allowed to rise. Consequently, soil CO2 flux will be affected because of the decreased CO2 diffusion gradient. To minimize the impact of decreased CO2 diffusion gradient on CO2 flux measurement in LI-8100M, the chamber CO2 concentration versus time is fitted with an exponential function. Soil CO2 flux is then estimated by calculating the initial slope from the exponential function at time zero when the chamber touches the soil, and that is when the chamber CO2 concentration is equal to the ambient. Our results show that the flux estimated from a linear function, the widely used method, could underestimate CO2 flux by more than 10% as compared with that from the exponential function. An

  3. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object’s position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.

  4. Accurate and fast fiber transfer delay measurement based on phase discrimination and frequency measurement

    CERN Document Server

    Dong, J W; Gao, C; Wang, L J

    2016-01-01

    An accurate and fast fiber transfer delay measurement method is demonstrated. As a key technique, a simple ambiguity resolving process based on phase discrimination and frequency measurement is used to overcome the contradiction between measurement accuracy and system complexity. The optimized system achieves a high accuracy of 0.3 ps with a 0.1 ps resolution, and a large dynamic range up to 50 km as well as no dead zone.

  5. Highly accurate fiber transfer delay measurement with large dynamic range

    CERN Document Server

    Dong, J W; Gao, C; Guo, Y C; Wang, L J

    2015-01-01

    A novel and efficient method for fiber transfer delay measurement is demonstrated. Fiber transfer delay measurement in time domain is converted into the frequency measurement of the modulation signal in frequency domain, accompany with a coarse and easy ambiguity resolving process. This method achieves a sub-picosecond resolution, with an accuracy of 1 picosecond, and a large dynamic range up to 50 km as well as no measurement dead zone.

  6. Refine test items for accurate measurement: six valuable tips.

    Science.gov (United States)

    Siroky, Karen; Di Leonardi, Bette Case

    2015-01-01

    Nursing Professional Development (NPD) specialists frequently design test items to assess competence, to measure learning outcomes, and to create active learning experiences. This article presents six valuable tips for improving test items and using test results to strengthen validity of measurement. NPD specialists can readily apply these tips and examples to measure knowledge with greater accuracy.

  7. ACCURATE MEASUREMENT OF ROTA-RY MACHINE AXIS CENTER TRACE

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Four methods aiming at measuring rotary machine axis center trace are discussed in detail.The comparative analysis is made on some aspects such as measurement accuracy, on-machine characteristics, feasibility, practical operation convenience and the integrity of measurement information.In order to simplify measurement, the axis profile error is ignored in traditional condition, while the measurement accuracy will be reduced.The 3-point method that the axis profile error is firstly separated has better real time character, at the same time, not only the axis motion error but also the axis profile error can be measured.All of those information can be used to diagnose the fault origin.The analysis result is proved to be correct by the experiment.

  8. Spherical near-field antenna measurements — The most accurate antenna measurement technique

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2016-01-01

    The spherical near-field antenna measurement technique combines several advantages and generally constitutes the most accurate technique for experimental characterization of radiation from antennas. This paper/presentation discusses these advantages, briefly reviews the early history and present...... status, and addresses future challenges for spherical near-field antenna measurements; in particular, from the viewpoint of the DTU-ESA Spherical Near-Field Antenna Test Facility....

  9. Problems with Accurate Atomic Lfetime Measurements of Multiply Charged Ions

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2009-02-19

    A number of recent atomic lifetime measurements on multiply charged ions have reported uncertainties lower than 1%. Such a level of accuracy challenges theory, which is a good thing. However, a few lessons learned from earlier precision lifetime measurements on atoms and singly charged ions suggest to remain cautious about the systematic errors of experimental techniques.

  10. Accurate micro Hall effect measurements on scribe line pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Wang, Fei

    2009-01-01

    Hall mobility and sheet carrier density are important parameters to monitor in advanced semiconductor production. If micro Hall effect measurements are done on small pads in scribe lines, these parameters may be measured without using valuable test wafers. We report how Hall mobility can...

  11. A new method and instrument for accurately measuring interval between ultrashort pulses

    Institute of Scientific and Technical Information of China (English)

    Zhonggang Ji; Yuxin Leng; Yunpei Deng; Bin Tang; Haihe Lu; Ruxin Li; Zhizhan Xu

    2005-01-01

    @@ Using second-order autocorrelation conception, a novel method and instrument for accurately measuring interval between two linearly polarized ultrashort pulses with real time were presented. The experiment demonstrated that the measuring method and instrument were simple and accurate (the measurement error < 5 fs). During measuring, there was no moving element resulting in dynamic measurement error.

  12. Apparatus designed for very accurate measurement of the optical reflection.

    Science.gov (United States)

    Piombini, Hervé; Voarino, Philippe

    2007-12-20

    The described instrument is a new reflectometer designed to check the normal specular reflectance of 40,000 reflectors necessary for the Laser Megajoule (LMJ). This new reflectometer has a high accuracy over the 400-950 nm wavelength range and allows the delicate measurement of shaped parts. The measurements are relative and several reference mirrors, which are low loss dielectric mirrors [R(lambda)>99.9%], are used for the standardization. The apparatus gives an excellent repeatability (spectrophotometers, our facility and its components are described. The methodology of focusing and calibration are explained. The capabilities of our device are illustrated through some measurements realized on flat or shaped samples.

  13. An accurate method for measuring triploidy of larval fish spawns

    Science.gov (United States)

    Jenkins, Jill A.; Draugelis-Dale, Rassa O.; Glennon, Robert; Kelly, Anita; Brown, Bonnie L.; Morrison, John

    2017-01-01

    A standard flow cytometric protocol was developed for estimating triploid induction in batches of larval fish. Polyploid induction treatments are not guaranteed to be 100% efficient, thus the ability to quantify the proportion of triploid larvae generated by a particular treatment helps managers to stock high-percentage spawns and researchers to select treatments for efficient triploid induction. At 3 d posthatch, individual Grass Carp Ctenopharyngodon idella were mechanically dissociated into single-cell suspensions; nuclear DNA was stained with propidium iodide then analyzed by flow cytometry. Following ploidy identification of individuals, aliquots of diploid and triploid cell suspensions were mixed to generate 15 levels (0–100%) of known triploidy (n = 10). Using either 20 or 50 larvae per level, the observed triploid percentages were lower than the known, actual values. Using nonlinear regression analyses, quadratic equations solved for triploid proportions in mixed samples and corresponding estimation reference plots allowed for predicting triploidy. Thus, an accurate prediction of the proportion of triploids in a spawn can be made by following a standard larval processing and analysis protocol with either 20 or 50 larvae from a single spawn, coupled with applying the quadratic equations or reference plots to observed flow cytometry results. Due to the universality of triploid DNA content being 1.5 times the diploid level and because triploid fish consist of fewer cells than diploids, this method should be applicable to other produced triploid fish species, and it may be adapted for use with bivalves or other species where batch analysis is appropriate.

  14. Accurate measurement of curvilinear shapes by Virtual Image Correlation

    OpenAIRE

    Semin, B; Auradou, H.; François, M.L.M.

    2011-01-01

    Abstract The proposed method allows the detection and the measurement, in the sense of metrology, of smooth elongated curvilinear shapes. Such measurements are required in many fields of physics, for example: mechanical engineering, biology or medicine (deflection of beams, fibers or filaments), fluid mechanics or chemistry (detection of fronts). Contrary to actual methods, the result is given in an analytical form of class C? (and not a finite set of locations or pixels) thus curv...

  15. Accurate antenna reflector loss measurements for radiometer calibration budget

    DEFF Research Database (Denmark)

    Skou, Niels

    1996-01-01

    Antenna reflector losses may play an important role in the calibration budget for a microwave radiometer. If the losses are small they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiat...... radiation. The paper describes how such measurements are carried out as well as a suitable experimental set-up. The main reflector of the European Space Agency's MIMR system is used to demonstrate the principle...

  16. Visual texture accurate material appearance measurement, representation and modeling

    CERN Document Server

    Haindl, Michal

    2013-01-01

    This book surveys the state of the art in multidimensional, physically-correct visual texture modeling. Features: reviews the entire process of texture synthesis, including material appearance representation, measurement, analysis, compression, modeling, editing, visualization, and perceptual evaluation; explains the derivation of the most common representations of visual texture, discussing their properties, advantages, and limitations; describes a range of techniques for the measurement of visual texture, including BRDF, SVBRDF, BTF and BSSRDF; investigates the visualization of textural info

  17. Third trimester ultrasound soft-tissue measurements accurately predicts macrosomia.

    Science.gov (United States)

    Maruotti, Giuseppe Maria; Saccone, Gabriele; Martinelli, Pasquale

    2017-04-01

    To evaluate the accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia. Electronic databases were searched from their inception until September 2015 with no limit for language. We included only studies assessing the accuracy of sonographic measurements of fetal soft tissue in the abdomen or thigh in the prediction of macrosomia  ≥34 weeks of gestation. The primary outcome was the accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia. We generated the forest plot for the pooled sensitivity and specificity with 95% confidence interval (CI). Additionally, summary receiver-operating characteristics (ROC) curves were plotted and the area under the curve (AUC) was also computed to evaluate the overall performance of the diagnostic test accuracy. Three studies, including 287 singleton gestations, were analyzed. The pooled sensitivity of sonographic measurements of abdominal or thigh fetal soft tissue in the prediction of macrosomia was 80% (95% CI: 66-89%) and the pooled specificity was 95% (95% CI: 91-97%). The AUC for diagnostic accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia was 0.92 and suggested high diagnostic accuracy. Third-trimester sonographic measurements of fetal soft tissue after 34 weeks may help to detect macrosomia with a high degree of accuracy. The pooled detection rate was 80%. A standardization of measurements criteria, reproducibility, building reference charts of fetal subcutaneous tissue and large studies to assess the optimal cutoff of fetal adipose thickness are necessary before the introduction of fetal soft-tissue markers in the clinical practice.

  18. ACCUWIND - Accurate wind speed measurements in wind energy - Summary report

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Dahlberg, J.-Å.; Cuerva, A.

    2006-01-01

    The cup anemometer is at present the standard instrument used for mean wind speed measurement in wind energy. It is being applied in high numbers around the world for wind energy assessments. It is also applied exclusively for accredited power performancemeasurements for certification...... and verification purposes, and for purposes of optimisation in research and development. The revised IEC standard on power performance measurements has now included requirements for classification of cup anemometers. Thebasis for setting up such requirements of cup anemometers is two EU projects SITEPARIDEN...... and CLASSCUP from which the proposed classification method for cup anemometers was developed for the IEC standard. While cup anemometers at present are the standardanemometer being used for average wind speed measurements, sonic anemometers have been developed significantly over the last years, and prices have...

  19. Highly Accurate Photogrammetric Measurements of the Planck Reflectors

    Science.gov (United States)

    Amiri Parian, J.; Gruen, Armin; Cozzani, Alessandro

    2006-06-01

    The Planck mission of the European Space Agency (ESA) is designed to image the anisotropies of the Cosmic Background Radiation Field over the whole sky. To achieve this aim, sophisticated reflectors are used as part of the Planck telescope receiving system. The system consists of secondary and primary reflectors which are sections of two different ellipsoids of revolution with mean diameters of 1 and 1.6 meters. Deformations of the reflectors which influence the optical parameters and the gain of receiving signals are investigated in vacuum and at very low temperatures. For this investigation, among the various high accuracy measurement techniques, photogrammetry was selected. With respect to the photogrammetric measurements, special considerations had to be taken into account in design steps, measurement arrangement and data processing to achieve very high accuracies. The determinability of additional parameters of the camera under the given network configuration, datum definition, reliability and precision issues as well as workspace limits and propagating errors from different sources are considered. We have designed an optimal photogrammetric network by heuristic simulation for the flight model of the primary and the secondary reflectors with relative precisions better than 1:1000000 and 1:400000 to achieve the requested accuracies. A least squares best fit ellipsoid method was developed to determine the optical parameters of the reflectors. In this paper we will report about the procedures, the network design and the results of real measurements.

  20. Convenient integrating sphere scanner for accurate luminous flux measurements

    Science.gov (United States)

    Winter, S.; Lindemann, M.; Jordan, W.; Binder, U.; Anokhin, M.

    2009-08-01

    Measurement results and applications of a recently developed device for the measurement of the spatial uniformity of integrating spheres are presented. Due to the complexity of their implementation, sphere scanners are mainly used by national metrology institutes to increase the accuracy of relative and absolute luminous flux measurements (Ohno et al 1997 J. IES 26 107-14, Ohno and Daubach 2001 J. IES 30 105-15, Ohno 1998 Metrologia 35 473-8, Hovila et al 2004 Metrologia 41 407-13). The major drawback of traditional scanners for integrating spheres is the necessity of a complex and time-consuming sphere modification, as the lamp holder has to be replaced by a new scanner holder with additional cables for power supply and for communication with the stepping motor control unit (Ohno et al 1997 J. IES 26 107-14). Therefore, with traditional scanners the relative spatial sphere responsivity already changes due to the installation of a special scanner holder. The new scanner simply substitutes the lamp under test: it can be screwed into an E27 lamp socket, as it needs only two electrical contacts. Two wires are simultaneously used for the power supply of the stepping motor control unit, the scanner light source (LED) and for the signal transmission of commands and results. The benefits of scanner-assisted measurements are shown for spotlight lamp calibrations.

  1. Measuring Fisher information accurately in correlated neural populations.

    Science.gov (United States)

    Kanitscheider, Ingmar; Coen-Cagli, Ruben; Kohn, Adam; Pouget, Alexandre

    2015-06-01

    Neural responses are known to be variable. In order to understand how this neural variability constrains behavioral performance, we need to be able to measure the reliability with which a sensory stimulus is encoded in a given population. However, such measures are challenging for two reasons: First, they must take into account noise correlations which can have a large influence on reliability. Second, they need to be as efficient as possible, since the number of trials available in a set of neural recording is usually limited by experimental constraints. Traditionally, cross-validated decoding has been used as a reliability measure, but it only provides a lower bound on reliability and underestimates reliability substantially in small datasets. We show that, if the number of trials per condition is larger than the number of neurons, there is an alternative, direct estimate of reliability which consistently leads to smaller errors and is much faster to compute. The superior performance of the direct estimator is evident both for simulated data and for neuronal population recordings from macaque primary visual cortex. Furthermore we propose generalizations of the direct estimator which measure changes in stimulus encoding across conditions and the impact of correlations on encoding and decoding, typically denoted by Ishuffle and Idiag respectively.

  2. Extremal eigenvalues of measure differential equations with fixed variation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper we will study eigenvalues of measure differential equations which are motivated by physical problems when physical quantities are not absolutely continuous.By taking Neumann eigenvalues of measure differential equations as an example,we will show how the extremal problems can be completely solved by exploiting the continuity results of eigenvalues in weak* topology of measures and the Lagrange multiplier rule for nonsmooth functionals.These results can give another explanation for extremal eigenvalues of SturmLiouville operators with integrable potentials.

  3. Accurate Measurement of Heat Capacity by Differential Scanning Calorimetry

    Science.gov (United States)

    1984-01-01

    Experience with high quality heat capacity measurement by differential scanning calorimetry is summarized and illustrated, pointing out three major causes of error: (1) incompatible thermal histories of the sample, reference and blank runs; (2) unstable initial and final isotherms; (3) incompatible differences between initial and final isotherm amplitudes for sample, reference and blank runs. Considering these problems, it is shown for the case of polyoxymethylene that accuracies in heat capacity of 0.1 percent may be possible.

  4. Accurate Measurement of Heat Capacity by Differential Scanning Calorimetry

    Science.gov (United States)

    1984-01-01

    Experience with high quality heat capacity measurement by differential scanning calorimetry is summarized and illustrated, pointing out three major causes of error: (1) incompatible thermal histories of the sample, reference and blank runs; (2) unstable initial and final isotherms; (3) incompatible differences between initial and final isotherm amplitudes for sample, reference and blank runs. Considering these problems, it is shown for the case of polyoxymethylene that accuracies in heat capacity of 0.1 percent may be possible.

  5. On uplimit of accurate measurement of tau mass

    CERN Document Server

    Mo, X H

    2016-01-01

    Tau lepton as one of three elementary leptons in nature, the measurement of its mass has ever been performed since its discovery. The present relative accuracy is already at the level of better than 10 to minus 4 and more effects are still made in order to increase the accuracy further. However, the analysis of available techniques for and expectable luminosity from e+e- collider indicates that the precision uplimit of tau mass is almost reached, which means that brand new approaches should be looked for if the great improvement is yearned for.

  6. Accurate blood flow measurements: are artificial tracers necessary?

    Science.gov (United States)

    Poelma, Christian; Kloosterman, Astrid; Hierck, Beerend P; Westerweel, Jerry

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case), as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements). These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  7. Accurate measurement of intestinal transit in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.S.; Galligan, J.J.; Burks, T.F.

    1981-11-01

    A new method for quantifying intestinal transit was evaluated by comparison with two other popular techniques. The distribution of radiochromium (51Cr) throughout the small intestine of rats previously treated with saline (1.0 ml/kg s.c.), capsaicin (10 mg/kg s.c.), hexamethonium (20 mg/kg i.p.), D-ala2-met-enkephalinamide (1.0 microgram i.c.v.), or neostigmine (0.1 mg/kg i.p.) was quantified by (1) measuring the most distal intestinal segment reached by chromium, (2) calculating the slope produced by linear regression analysis on cumulative percent chromium that had passed through each segment, and (3) determining the geometric center of the distribution of chromium throughout the small intestine. It was concluded that the geometric center methods for quantifying intestinal transit provides the most sensitive and reliable measure of intestinal transit. Less sensitive techniques often fail to detect important effects of drugs on intestinal transit.

  8. Accurate measurement of curvilinear shapes by Virtual Image Correlation

    Science.gov (United States)

    Semin, B.; Auradou, H.; François, M. L. M.

    2011-10-01

    The proposed method allows the detection and the measurement, in the sense of metrology, of smooth elongated curvilinear shapes. Such measurements are required in many fields of physics, for example: mechanical engineering, biology or medicine (deflection of beams, fibers or filaments), fluid mechanics or chemistry (detection of fronts). Contrary to actual methods, the result is given in an analytical form of class C∞ (and not a finite set of locations or pixels) thus curvatures and slopes, often of great interest in science, are given with good confidence. The proposed Virtual Image Correlation (VIC) method uses a virtual beam, an image which consists in a lateral expansion of the curve with a bell-shaped gray level. This figure is deformed until it fits the best the physical image with a method issued from the Digital Image Correlation method in use in solid mechanics. The precision of the identification is studied in a benchmark and successfully compared to two state-of-the-art methods. Three practical examples are given: a bar bending under its own weight, a thin fiber transported by a flow within a fracture and a thermal front. The first allows a comparison with theoretical solution, the second shows the ability of the method to deal with complex shapes and crossings and the third deals with ill-defined image.

  9. Accurate blood flow measurements: are artificial tracers necessary?

    Directory of Open Access Journals (Sweden)

    Christian Poelma

    Full Text Available Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case, as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements. These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  10. Blood-Pressure Measuring System Gives Accurate Graphic Output

    Science.gov (United States)

    1965-01-01

    The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

  11. Accurate on line measurements of low fluences of charged particles

    Science.gov (United States)

    Palla, L.; Czelusniak, C.; Taccetti, F.; Carraresi, L.; Castelli, L.; Fedi, M. E.; Giuntini, L.; Maurenzig, P. R.; Sottili, L.; Taccetti, N.

    2015-03-01

    Ion beams supplied by the 3MV Tandem accelerator of LABEC laboratory (INFN-Firenze), have been used to study the feasibility of irradiating materials with ion fluences reproducible to about 1%. Test measurements have been made with 7.5 MeV 7Li2+ beams of different intensities. The fluence control is based on counting ions contained in short bursts generated by chopping the continuous beam with an electrostatic deflector followed by a couple of adjustable slits. Ions are counted by means of a micro-channel plate (MCP) detecting the electrons emitted from a thin layer of Al inserted along the beam path in between the pulse defining slits and the target. Calibration of the MCP electron detector is obtained by comparison with the response of a Si detector.

  12. On accurate differential measurements with electrochemical impedance spectroscopy

    CERN Document Server

    Kernbach, S; Kernbach, O

    2016-01-01

    This paper describes the impedance spectroscopy adapted for analysis of small electrochemical changes in fluids. To increase accuracy of measurements the differential approach with temperature stabilization of fluid samples and electronics is used. The impedance analysis is performed by the single point DFT, signal correlation, calculation of RMS amplitudes and interference phase shift. For test purposes the samples of liquids and colloids are treated by fully shielded electromagnetic generators and passive cone-shaped structures. Fluidic samples collected from different geological locations are also analysed. In all tested cases we obtained different results for impacted and non-impacted samples, moreover, a degradation of electrochemical stability after treatment is observed. This method is used in laboratory analysis of weak emissions and ensures a high repeatability of results.

  13. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  14. Numerical assessment of accurate measurements of laminar flame speed

    Science.gov (United States)

    Goulier, Joules; Bizon, Katarzyna; Chaumeix, Nabiha; Meynet, Nicolas; Continillo, Gaetano

    2016-12-01

    In combustion, the laminar flame speed constitutes an important parameter that reflects the chemistry of oxidation for a given fuel, along with its transport and thermal properties. Laminar flame speeds are used (i) in turbulent models used in CFD codes, and (ii) to validate detailed or reduced mechanisms, often derived from studies using ideal reactors and in diluted conditions as in jet stirred reactors and in shock tubes. End-users of such mechanisms need to have an assessment of their capability to predict the correct heat released by combustion in realistic conditions. In this view, the laminar flame speed constitutes a very convenient parameter, and it is then very important to have a good knowledge of the experimental errors involved with its determination. Stationary configurations (Bunsen burners, counter-flow flames, heat flux burners) or moving flames (tubes, spherical vessel, soap bubble) can be used. The spherical expanding flame configuration has recently become popular, since it can be used at high pressures and temperatures. With this method, the flame speed is not measured directly, but derived through the recording of the flame radius. The method used to process the radius history will have an impact on the estimated flame speed. Aim of this work is to propose a way to derive the laminar flame speed from experimental recording of expanding flames, and to assess the error magnitude.

  15. Accurate measurement of microscopic forces and torques using optical tweezers

    Directory of Open Access Journals (Sweden)

    Andrew Forbes

    2011-09-01

    Full Text Available It is now well known that matter may be trapped by optical fields with high intensity gradients. Once trapped, it is then possible to manipulate microscopic particles using such optical fields, in so-called optical tweezers. Such optical trapping and tweezing systems have found widespread application across diverse fields in science, from applied biology to fundamental physics. In this article we outline the design and construction of an optical trapping and tweezing system, and show how the resulting interaction of the laser light with microscopic particles may be understood in terms of the transfer of linear and angular momentum of light. We demonstrate experimentally the use of our optical tweezing configuration for the measurement of microscopic forces and torques. In particular, we make use of digital holography to create so-called vortex laser beams, capable of transferring orbital angular momentum to particles. The use of such novel laser beams in an optical trapping and tweezing set-up allows for the control of biological species at the single-cell level.

  16. Accurate PSF-matched photometry and photometric redshifts for the Extreme Deep Field with the Chebyshev-Fourier functions

    CERN Document Server

    Jiménez-Teja, Y; Molino, A; Fernandes, C A C

    2015-01-01

    Photometric redshifts, which have become the cornerstone of several of the largest astronomical surveys like PanStarrs, DES, J-PAS or the LSST, require precise measurements of galaxy photometry in different bands using a consistent physical aperture. This is not trivial, due to the variation in the shape and width of the Point Spread Function (PSF) introduced by wavelength differences, instrument positions and atmospheric conditions. Current methods to correct for this effect rely on a detailed knowledge of the PSF characteristics as a function of the survey coordinates, which can be difficult due to the relative paucity of stars tracking the PSF behaviour. Here we show that it is possible to measure accurate, consistent multicolour photometry without knowing the shape of PSF. The Chebyshev-Fourier Functions (CHEFs) can fit the observed profile of each object and produce high signal-to-noise integrated flux measurements unaffected by the PSF. These total fluxes, which encompass all the galaxy populations, are...

  17. How good are remote sensors at measuring extreme winds?

    NARCIS (Netherlands)

    Sathe, A.R.; Courtney, M.; Mann, J.; Wagner, R.

    2011-01-01

    This article describes some preliminary efforts within the SafeWind project, aimed to identify the possible added value of using wind lidars to detect extreme wind events. Exceptionally good performance is now regularly reported in the measurement of the mean wind speed with some wind lidars in flat

  18. How good are remote sensors at measuring extreme winds?

    NARCIS (Netherlands)

    Sathe, A.R.; Courtney, M.; Mann, J.; Wagner, R.

    2011-01-01

    This article describes some preliminary efforts within the SafeWind project, aimed to identify the possible added value of using wind lidars to detect extreme wind events. Exceptionally good performance is now regularly reported in the measurement of the mean wind speed with some wind lidars in flat

  19. Colorimetric measurement of triglycerides cannot provide an accurate measure of stored fat content in Drosophila.

    Directory of Open Access Journals (Sweden)

    Bader Al-Anzi

    Full Text Available Drosophila melanogaster has recently emerged as a useful model system in which to study the genetic basis of regulation of fat storage. One of the most frequently used methods for evaluating the levels of stored fat (triglycerides in flies is a coupled colorimetric assay available as a kit from several manufacturers. This is an aqueous-based enzymatic assay that is normally used for measurement of mammalian serum triglycerides, which are present in soluble lipoprotein complexes. In this short communication, we show that coupled colorimetric assay kits cannot accurately measure stored triglycerides in Drosophila. First, they fail to give accurate readings when tested on insoluble triglyceride mixtures with compositions like that of stored fat, or on fat extracted from flies with organic solvents. This is probably due to an inability of the lipase used in the kits to efficiently cleave off the glycerol head group from fat molecules in insoluble samples. Second, the measured final products of the kits are quinoneimines, which absorb visible light in the same wavelength range as Drosophila eye pigments. Thus, when extracts from crushed flies are assayed, much of the measured signal is actually due to eye pigments. Finally, the lipoprotein lipases used in colorimetric assays also cleave non-fat glycerides. The glycerol backbones liberated from all classes of glycerides are measured through the remaining reactions in the assay. As a consequence, when these assay kits are used to evaluate tissue extracts, the observed signal actually represents the amount of free glycerols together with all types of glycerides. For these reasons, findings obtained through use of coupled colorimetric assays on Drosophila samples must be interpreted with caution. We also show here that using thin-layer chromatography to measure stored triglycerides in flies eliminates all of these problems.

  20. How good are remote sensors at measuring extreme winds?

    OpenAIRE

    Sathe, A.R.; Courtney, M; Mann, J.; Wagner, R.

    2011-01-01

    This article describes some preliminary efforts within the SafeWind project, aimed to identify the possible added value of using wind lidars to detect extreme wind events. Exceptionally good performance is now regularly reported in the measurement of the mean wind speed with some wind lidars in flat terrain. For turbulence measurements, recent theoretical work has revealed that the components of the Reynolds stress tensor are subjected to significant spatial attenuation and contamination by t...

  1. High-Frequency CTD Measurements for Accurate GPS/acoustic Sea-floor Crustal Deformation Measurement System

    Science.gov (United States)

    Tadokoro, K.; Yasuda, K.; Taniguchi, S.; Uemura, Y.; Matsuhiro, K.

    2015-12-01

    The GPS/acoustic sea-floor crustal deformation measurement system has developed as a useful tool to observe tectonic deformation especially at subduction zones. One of the factors preventing accurate GPS/acoustic sea-floor crustal deformation measurement is horizontal heterogeneity of sound speed in the ocean. It is therefore necessary to measure the gradient directly from sound speed structure. We report results of high-frequency CTD measurements using Underway CTD (UCTD) in the Kuroshio region. We perform the UCTD measurements on May 2nd, 2015 at two stations (TCA and TOA) above the sea-floor benchmarks installed across the Nankai Trough, off the south-east of Kii Peninsula, middle Japan. The number of measurement points is six at each station along circles with a diameter of 1.8 nautical miles around the sea-floor benchmark. The stations TCA and TOA are located on the edge and the interior of the Kuroshio current, respectively, judging from difference in sea water density measured at the two stations, as well as a satellite image of sea-surface temperature distribution. We detect a sound speed gradient of high speeds in the southern part and low speeds in the northern part at the two stations. At the TCA station, the gradient is noticeable down to 300 m in depth; the maximum difference in sound speed is +/- 5 m/s. The sound speed difference is as small as +/- 1.3 m/s at depths below 300 m, which causes seafloor benchmark positioning error as large as 1 m. At the TOA station, the gradient is extremely small down to 100 m in depth. The maximum difference in sound speed is less than +/- 0.3 m/s that is negligible small for seafloor benchmark positioning error. Clear gradient of high speed is observed to the depths; the maximum difference in sound speed is +/- 0.8-0.9 m/s, causing seafloor benchmark positioning error of several tens centimeters. The UCTD measurement is effective tool to detect sound speed gradient. We establish a method for accurate sea

  2. Accounting for choice of measurement scale in extreme value modeling

    OpenAIRE

    Wadsworth, J. L.; Tawn, J. A.; Jonathan, P.

    2010-01-01

    We investigate the effect that the choice of measurement scale has upon inference and extrapolation in extreme value analysis. Separate analyses of variables from a single process on scales which are linked by a nonlinear transformation may lead to discrepant conclusions concerning the tail behavior of the process. We propose the use of a Box--Cox power transformation incorporated as part of the inference procedure to account parametrically for the uncertainty surrounding the scale of extrapo...

  3. Measuring risk of crude oil at extreme quantiles

    Directory of Open Access Journals (Sweden)

    Saša Žiković

    2011-06-01

    Full Text Available The purpose of this paper is to investigate the performance of VaR models at measuring risk for WTI oil one-month futures returns. Risk models, ranging from industry standards such as RiskMetrics and historical simulation to conditional extreme value model, are used to calculate commodity market risk at extreme quantiles: 0.95, 0.99, 0.995 and 0.999 for both long and short trading positions. Our results show that out of the tested fat tailed distributions, generalised Pareto distribution provides the best fit to both tails of oil returns although tails differ significantly, with the right tail having a higher tail index, indicative of more extreme events. The main conclusion is that, in the analysed period, only extreme value theory based models provide a reasonable degree of safety while widespread VaR models do not provide adequate risk coverage and their performance is especially weak for short position in oil.

  4. Measuring the effects of extreme weather events on yields

    Directory of Open Access Journals (Sweden)

    J.P. Powell

    2016-06-01

    Full Text Available Extreme weather events are expected to increase worldwide, therefore, anticipating and calculating their effects on crop yields is important for topics ranging from food security to the economic viability of biomass products. Given the local nature of weather, particularly precipitation, effects are best measured at a local level. This paper analyzes weather events at the level of the farm for a specific crop, winter wheat. Once it has been established that extreme events are expected to continue occurring at historically high levels for farming locations throughout the Netherlands, the effects of those events on wheat yields are estimated while controlling for the other major input factors affecting yields. Econometric techniques are applied to an unbalanced panel data set of 334 farms for a period of up to 12 years. Analyzes show that the number of days with extreme high temperatures in Dutch wheat growing regions has significantly increased since the early 1900s, while the number of extreme low temperature events has fallen over that same period. The effects of weather events on wheat yields were found to be time specific in that the week in which an event occurred determined its effect on yields. High temperature events and precipitation events were found to significantly decrease yields.

  5. Technique of torsion measurement of the lower extremity using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Widjaja, P.M.; Ermers, J.W.; Sijbrandij, S.; Damsma, H.; Klinkhamer, A.C.

    1985-05-01

    Axial CT is the most accurate and convenient technique for the measurement of lower limb torsion; its accuracy is equal to that of cadaveric skeletal measurement. Both extremities are examined simultaneously, and the comparison of the right and the left leg provides the most important value. The torsion angulation is obtained directly by superimposing the magnified image of each scan on the other. Patient positioning is comfortable and a relatively short examination time is required. It does not require special equipment or skill on the part of the examiner. The radiation dose appears to be lower than that of the conventional radiographic method.

  6. Measurement with verification of stationary signals and noise in extremely quiet environments: measuring below the noise floor.

    Science.gov (United States)

    Ellingson, Roger M; Gallun, Frederick J; Bock, Guillaume

    2015-03-01

    It can be problematic to measure stationary acoustic sound pressure level in any environment when the target level approaches or lies below the minimum measureable sound pressure level of the measurement system itself. This minimum measureable level, referred to as the inherent measurement system noise floor, is generally established by noise emission characteristics of measurement system components such as microphones, preamplifiers, and other system circuitry. In this paper, methods are presented and shown accurate measuring stationary levels within 20 dB above and below this system noise floor. Methodology includes (1) measuring inherent measurement system noise, (2) subtractive energy based, inherent noise adjustment of levels affected by system noise floor, and (3) verifying accuracy of inherent noise adjustment technique. While generalizable to other purposes, the techniques presented here were specifically developed to quantify ambient noise levels in very quiet rooms used to evaluate free-field human hearing thresholds. Results obtained applying the methods to objectively measure and verify the ambient noise level in an extremely quiet room, using various measurement system noise floors and analysis bandwidths, are presented and discussed. The verified results demonstrate the adjustment method can accurately extend measurement range to 20 dB below the measurement system noise floor, and how measurement system frequency bandwidth can affect accuracy of reported noise levels.

  7. Standardized voluntary force measurement in a lower extremity rehabilitation robot

    Directory of Open Access Journals (Sweden)

    Bolliger Marc

    2008-10-01

    Full Text Available Abstract Background Isometric force measurements in the lower extremity are widely used in rehabilitation of subjects with neurological movement disorders (NMD because walking ability has been shown to be related to muscle strength. Therefore muscle strength measurements can be used to monitor and control the effects of training programs. A new method to assess isometric muscle force was implemented in the driven gait orthosis (DGO Lokomat. To evaluate the capabilities of this new measurement method, inter- and intra-rater reliability were assessed. Methods Reliability was assessed in subjects with and without NMD. Subjects were tested twice on the same day by two different therapists to test inter-rater reliability and on two separate days by the same therapist to test intra-rater reliability. Results Results showed fair to good reliability for the new measurement method to assess isometric muscle force of lower extremities. In subjects without NMD, intraclass correlation coefficients (ICC for inter-rater reliability ranged from 0.72 to 0.97 and intra-rater reliability from 0.71 to 0.90. In subjects with NMD, ICC ranged from 0.66 to 0.97 for inter-rater and from 0.50 to 0.96 for intra-rater reliability. Conclusion Inter- and intra- rater reliability of an assessment method for measuring maximal voluntary isometric muscle force of lower extremities was demonstrated. We suggest that this method is a valuable tool for documentation and controlling of the rehabilitation process in patients using a DGO.

  8. A hybrid solution using computational prediction and measured data to accurately determine process corrections with reduced overlay sampling

    Science.gov (United States)

    Noyes, Ben F.; Mokaberi, Babak; Mandoy, Ram; Pate, Alex; Huijgen, Ralph; McBurney, Mike; Chen, Owen

    2017-03-01

    Reducing overlay error via an accurate APC feedback system is one of the main challenges in high volume production of the current and future nodes in the semiconductor industry. The overlay feedback system directly affects the number of dies meeting overlay specification and the number of layers requiring dedicated exposure tools through the fabrication flow. Increasing the former number and reducing the latter number is beneficial for the overall efficiency and yield of the fabrication process. An overlay feedback system requires accurate determination of the overlay error, or fingerprint, on exposed wafers in order to determine corrections to be automatically and dynamically applied to the exposure of future wafers. Since current and future nodes require correction per exposure (CPE), the resolution of the overlay fingerprint must be high enough to accommodate CPE in the overlay feedback system, or overlay control module (OCM). Determining a high resolution fingerprint from measured data requires extremely dense overlay sampling that takes a significant amount of measurement time. For static corrections this is acceptable, but in an automated dynamic correction system this method creates extreme bottlenecks for the throughput of said system as new lots have to wait until the previous lot is measured. One solution is using a less dense overlay sampling scheme and employing computationally up-sampled data to a dense fingerprint. That method uses a global fingerprint model over the entire wafer; measured localized overlay errors are therefore not always represented in its up-sampled output. This paper will discuss a hybrid system shown in Fig. 1 that combines a computationally up-sampled fingerprint with the measured data to more accurately capture the actual fingerprint, including local overlay errors. Such a hybrid system is shown to result in reduced modelled residuals while determining the fingerprint, and better on-product overlay performance.

  9. An Electrostatics Approach to the Determination of Extremal Measures

    Energy Technology Data Exchange (ETDEWEB)

    Meinguet, Jean [Universite Catholique de Louvain, Institut Mathematique, Chemin du Cyclotron 2 (Belgium)], E-mail: meinguet@anma.ucl.ac.be

    2000-12-15

    One of the most important aspects of the minimal energy (or induced equilibrium) problem in the presence of an external field - sometimes referred to as the Gauss variation problem - is the determination of the support of its solution (the so-called extremal measure associated with the field). A simple electrostatic interpretation is presented here, which is apparently new and anyway suggests a novel, rather systematic approach to the solution. By way of illustration, the classical results for Jacobi, Laguerre and Freud weights are explicitly recovered by this alternative method.

  10. Wound size measurement of lower extremity ulcers using segmentation algorithms

    Science.gov (United States)

    Dadkhah, Arash; Pang, Xing; Solis, Elizabeth; Fang, Ruogu; Godavarty, Anuradha

    2016-03-01

    Lower extremity ulcers are one of the most common complications that not only affect many people around the world but also have huge impact on economy since a large amount of resources are spent for treatment and prevention of the diseases. Clinical studies have shown that reduction in the wound size of 40% within 4 weeks is an acceptable progress in the healing process. Quantification of the wound size plays a crucial role in assessing the extent of healing and determining the treatment process. To date, wound healing is visually inspected and the wound size is measured from surface images. The extent of wound healing internally may vary from the surface. A near-infrared (NIR) optical imaging approach has been developed for non-contact imaging of wounds internally and differentiating healing from non-healing wounds. Herein, quantitative wound size measurements from NIR and white light images are estimated using a graph cuts and region growing image segmentation algorithms. The extent of the wound healing from NIR imaging of lower extremity ulcers in diabetic subjects are quantified and compared across NIR and white light images. NIR imaging and wound size measurements can play a significant role in potentially predicting the extent of internal healing, thus allowing better treatment plans when implemented for periodic imaging in future.

  11. MELIFT - A new device for accurate measurements in a snow rich environment

    Science.gov (United States)

    Dorninger, M.

    2012-04-01

    A deep snow pack, remote locations, no external power supply and very low temperatures are often the main ingredients when it comes to the deployment of meteorological stations in mountainous terrain. The accurate position of the sensor related to the snow surface is normally not known. A new device called METLIFT overcomes the problems. WMO recommends a height between 1.2 m and 2 m above ground level for the measurement of air temperature and humidity. The height above ground level is specified to take care of the possible strong vertical temperature and humidity gradients at the lowest layers in the atmosphere. Especially in snow rich and remote locations it may be hardly possible to follow this advice. Therefore most of the meteorological stations in mountainous terrain are situated at mountain tops where strong winds will blow off the snow or in valleys where a daily inspection of the sensors is possible. In other unpopulated mountainous areas, e.g. basins, plateaus, the distance of the sensor to the snow surface is not known or the sensor will be snow-covered. A new device was developed to guarantee the sensor height above surface within the WMO limits in harsh and remote environments. An ultrasonic snow height sensor measures the distance to the snow surface. If it exceeds certain limits due to snow accumulation or snow melt the lift adapts its height accordingly. The prototype of METLIFT has been installed in Lower Austria at an altitude of 1000m. The lift is 6 m high and can pull out for another 4 m. Sensor arms are mounted every meter to allow the connection of additional sensors or to measure a profile of a certain parameter of the lowest 5 m above surface. Sensors can be added easily since cable wiring is provided to each sensor arm. Horizontal winds are measured at 7 m height above surface. METLIFT is independent of external power supply. Three lead gel accumulators recharged by three solar panels provide the energy necessary for the sensors, the data

  12. Defining Allowable Physical Property Variations for High Accurate Measurements on Polymer Parts

    DEFF Research Database (Denmark)

    Mohammadi, Ali; Sonne, Mads Rostgaard; Madruga, Daniel González

    2015-01-01

    cooling down after injection molding. In order to obtain accurate simulations, accurate inputs to the model are crucial. In reality however, the material and physical properties will have some variations. Although these variations may be small, they can act as a source of uncertainty for the measurement....... In this paper, we investigated how big the variation in material and physical properties are allowed in order to reach the 5 μm target on the uncertainty....

  13. Measuring Accurate Body Parameters of Dressed Humans with Large-Scale Motion Using a Kinect Sensor

    Directory of Open Access Journals (Sweden)

    Sidan Du

    2013-08-01

    Full Text Available Non-contact human body measurement plays an important role in surveillance, physical healthcare, on-line business and virtual fitting. Current methods for measuring the human body without physical contact usually cannot handle humans wearing clothes, which limits their applicability in public environments. In this paper, we propose an effective solution that can measure accurate parameters of the human body with large-scale motion from a Kinect sensor, assuming that the people are wearing clothes. Because motion can drive clothes attached to the human body loosely or tightly, we adopt a space-time analysis to mine the information across the posture variations. Using this information, we recover the human body, regardless of the effect of clothes, and measure the human body parameters accurately. Experimental results show that our system can perform more accurate parameter estimation on the human body than state-of-the-art methods.

  14. Defining Allowable Physical Property Variations for High Accurate Measurements on Polymer Parts

    DEFF Research Database (Denmark)

    Mohammadi, Ali; Sonne, Mads Rostgaard; Madruga, Daniel González;

    2015-01-01

    cooling down after injection molding. In order to obtain accurate simulations, accurate inputs to the model are crucial. In reality however, the material and physical properties will have some variations. Although these variations may be small, they can act as a source of uncertainty for the measurement...... high accurate measurements in non-controlled ambient. Most of polymer parts are manufactured by injection moulding and their inspection is carried out after stabilization, around 200 hours. The overall goal of this work is to reach ±5μm in uncertainty measurements a polymer products which...... is a challenge in today‘s production and metrology environments. The residual deformations in polymer products at room temperature after injection molding are important when micrometer accuracy needs to be achieved. Numerical modelling can give a valuable insight to what is happening in the polymer during...

  15. No galaxy left behind: accurate measurements with the faintest objects in the Dark Energy Survey

    CERN Document Server

    Suchyta, E; Aleksić, J; Melchior, P; Jouvel, S; MacCrann, N; Crocce, M; Gaztanaga, E; Honscheid, K; Leistedt, B; Peiris, H V; Ross, A J; Rykoff, E S; Sheldon, E; Abbott, T; Abdalla, F B; Allam, S; Banerji, M; Benoit-Lévy, A; Bertin, E; Brooks, D; Burke, D L; Rosell, A Carnero; Kind, M Carrasco; Carretero, J; Cunha, C E; D'Andrea, C B; da Costa, L N; DePoy, D L; Desai, S; Diehl, H T; Dietrich, J P; Doel, P; Eifler, T F; Estrada, J; Evrard, A E; Flaugher, B; Fosalba, P; Frieman, J; Gerdes, D W; Gruen, D; Gruendl, R A; James, D J; Jarvis, M; Kuehn, K; Kuropatkin, N; Lahav, O; Lima, M; Maia, M A G; March, M; Marshall, J L; Miller, C J; Miquel, R; Neilsen, E; Nichol, R C; Nord, B; Ogando, R; Percival, W J; Reil, K; Roodman, A; Sako, M; Sanchez, E; Scarpine, V; Sevilla-Noarbe, I; Smith, R C; Soares-Santos, M; Sobreira, F; Swanson, M E C; Tarle, G; Thaler, J; Thomas, D; Vikram, V; Walker, A R; Wechsler, R H; Zhang, Y

    2015-01-01

    Accurate statistical measurement with large imaging surveys has traditionally required throwing away a sizable fraction of the data. This is because most measurements have have relied on selecting nearly complete samples, where variations in the composition of the galaxy population with seeing, depth, or other survey characteristics are small. We introduce a new measurement method that aims to minimize this wastage, allowing precision measurement for any class of stars or galaxies detectable in an imaging survey. We have implemented our proposal in Balrog, a software package which embeds fake objects in real imaging in order to accurately characterize measurement biases. We demonstrate this technique with an angular clustering measurement using Dark Energy Survey (DES) data. We first show that recovery of our injected galaxies depends on a wide variety of survey characteristics in the same way as the real data. We then construct a flux-limited sample of the faintest galaxies in DES, chosen specifically for th...

  16. From dimer to condensed phases at extreme conditions: accurate predictions of the properties of water by a Gaussian charge polarizable model.

    Science.gov (United States)

    Paricaud, Patrice; Predota, Milan; Chialvo, Ariel A; Cummings, Peter T

    2005-06-22

    Water exhibits many unusual properties that are essential for the existence of life. Water completely changes its character from ambient to supercritical conditions in a way that makes it possible to sustain life at extreme conditions, leading to conjectures that life may have originated in deep-sea vents. Molecular simulation can be very useful in exploring biological and chemical systems, particularly at extreme conditions for which experiments are either difficult or impossible; however this scenario entails an accurate molecular model for water applicable over a wide range of state conditions. Here, we present a Gaussian charge polarizable model (GCPM) based on the model developed earlier by Chialvo and Cummings [Fluid Phase Equilib. 150, 73 (1998)] which is, to our knowledge, the first that satisfies the water monomer and dimer properties, and simultaneously yields very accurate predictions of dielectric, structural, vapor-liquid equilibria, and transport properties, over the entire fluid range. This model would be appropriate for simulating biological and chemical systems at both ambient and extreme conditions. The particularity of the GCPM model is the use of Gaussian distributions instead of points to represent the partial charges on the water molecules. These charge distributions combined with a dipole polarizability and a Buckingham exp-6 potential are found to play a crucial role for the successful and simultaneous predictions of a variety of water properties. This work not only aims at presenting an accurate model for water, but also at proposing strategies to develop classical accurate models for the predictions of structural, dynamic, and thermodynamic properties.

  17. Assessment of dynamic balance via measurement of lower extremities tortuosity.

    Science.gov (United States)

    Eltoukhy, Moataz; Kuenze, Christopher; Jun, Hyung-Pil; Asfour, Shihab; Travascio, Francesco

    2015-03-01

    Tortuosity describes how twisted or how much curvature is present in an observed movement or path. The purpose of this study was to investigate the differences in segmental tortuosity between Star Excursion Balance Test (SEBT) reach directions. Fifteen healthy participants completed this study. Participants completed the modified three direction (anterior, posteromedial, posterolateral) SEBT with three-dimensional motion analysis using an 8 camera BTS Smart 7000DX motion analysis system. The tortuosity of stance limb retro-reflective markers was then calculated and compared between reach directions using a 1 × 3 ANOVA with repeated measures, while the relationship between SEBT performance and tortuosity was established using Pearson product moment correlations. Anterior superior iliac spine tortuosity was significantly greater (p < 0.001) and lateral knee tortuosity was lesser (p = 0.018) in the anterior direction compared to the posteromedial and posterolateral directions. In addition, second metatarsal tortuosity was greater in the anterior reach direction when compared to posteromedial direction (p = 0.024). Tortuosity is a novel biomechanical measurement technique that provides an assessment of segmental movement during common dynamic tasks such as the SEBT. This enhanced level of detail compared to more global measures of joint kinematic may provide insight into compensatory movement strategies adopted following lower extremity joint injury.

  18. Ocean Lidar Measurements of Beam Attenuation and a Roadmap to Accurate Phytoplankton Biomass Estimates

    Directory of Open Access Journals (Sweden)

    Hu Yongxiang

    2016-01-01

    On July 17, 2014, the CALIPSO satellite was tilted 30° off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL data that are collocated with in-water optical measurements.

  19. Importance of Accurate Measurements in Nutrition Research: Dietary Flavonoids as a Case Study

    Science.gov (United States)

    Accurate measurements of the secondary metabolites in natural products and plant foods are critical to establishing diet/health relationships. There are as many as 50,000 secondary metabolites which may influence human health. Their structural and chemical diversity present a challenge to analytic...

  20. An investigation of highly accurate and precise robotic hole measurements using non-contact devices

    Directory of Open Access Journals (Sweden)

    Usman Zahid

    2016-01-01

    Full Text Available Industrial robots arms are widely used in manufacturing industry because of their support for automation. However, in metrology, robots have had limited application due to their insufficient accuracy. Even using error compensation and calibration methods, robots are not effective for micrometre (μm level metrology. Non-contact measurement devices can potentially enable the use of robots for highly accurate metrology. However, the use of such devices on robots has not been investigated. The research work reported in this paper explores the use of different non-contact measurement devices on an industrial robot. The aim is to experimentally investigate the effects of robot movements on the accuracy and precision of measurements. The focus has been on assessing the ability to accurately measure various geometric and surface parameters of holes despite the inherent inaccuracies of industrial robot. This involves the measurement of diameter, roundness and surface roughness. The study also includes scanning of holes for measuring internal features such as start and end point of a taper. Two different non-contact measurement devices based on different technologies are investigated. Furthermore, effects of eccentricity, vibrations and thermal variations are also assessed. The research contributes towards the use of robots for highly accurate and precise robotic metrology.

  1. Evaluation of Modified Pycnometric Method for Accurately Measuring the Density of Molten Nickel

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    A modified pycnometric method has been developed to obtain accurate densities of molten nickel.The new method allows continuous measurement of density over a wide temperature range from a single experiment.The measurement error of the method was analyzed, and the total uncertainty of the measurement was estimated to be within ±0.34%. The measured density of molten nickel decreases linearly with increasing temperature over a range from the melting point to 1873K. The density at the melting point and the thermal expansion coefficient of molten nickel are 7.90Mg·m-3 and 1.92×10-4 K-1,respectively.

  2. Techniques for determining propulsion system forces for accurate high speed vehicle drag measurements in flight

    Science.gov (United States)

    Arnaiz, H. H.

    1975-01-01

    As part of a NASA program to evaluate current methods of predicting the performance of large, supersonic airplanes, the drag of the XB-70 airplane was measured accurately in flight at Mach numbers from 0.75 to 2.5. This paper describes the techniques used to determine engine net thrust and the drag forces charged to the propulsion system that were required for the in-flight drag measurements. The accuracy of the measurements and the application of the measurement techniques to aircraft with different propulsion systems are discussed. Examples of results obtained for the XB-70 airplane are presented.

  3. Accurate mass replacement method for the sediment concentration measurement with a constant volume container

    Science.gov (United States)

    Ban, Yunyun; Chen, Tianqin; Yan, Jun; Lei, Tingwu

    2017-04-01

    The measurement of sediment concentration in water is of great importance in soil erosion research and soil and water loss monitoring systems. The traditional weighing method has long been the foundation of all the other measuring methods and instrument calibration. The development of a new method to replace the traditional oven-drying method is of interest in research and practice for the quick and efficient measurement of sediment concentration, especially field measurements. A new method is advanced in this study for accurately measuring the sediment concentration based on the accurate measurement of the mass of the sediment-water mixture in the confined constant volume container (CVC). A sediment-laden water sample is put into the CVC to determine its mass before the CVC is filled with water and weighed again for the total mass of the water and sediments in the container. The known volume of the CVC, the mass of sediment-laden water, and sediment particle density are used to calculate the mass of water, which is replaced by sediments, therefore sediment concentration of the sample is calculated. The influence of water temperature was corrected by measuring water density to determine the temperature of water before measurements were conducted. The CVC was used to eliminate the surface tension effect so as to obtain the accurate volume of water and sediment mixture. Experimental results showed that the method was capable of measuring the sediment concentration from 0.5 up to 1200 kg m‑3. A good liner relationship existed between the designed and measured sediment concentrations with all the coefficients of determination greater than 0.999 and the averaged relative error less than 0.2%. All of these seem to indicate that the new method is capable of measuring a full range of sediment concentration above 0.5 kg m‑3 to replace the traditional oven-drying method as a standard method for evaluating and calibrating other methods.

  4. Defining allowable physical property variations for high accurate measurements on polymer parts

    Science.gov (United States)

    Mohammadi, A.; Sonne, M. R.; Madruga, D. G.; De Chiffre, L.; Hattel, J. H.

    2016-06-01

    Measurement conditions and material properties have a significant impact on the dimensions of a part, especially for polymers parts. Temperature variation causes part deformations that increase the uncertainty of the measurement process. Current industrial tolerances of a few micrometres demand high accurate measurements in non-controlled ambient. Most of polymer parts are manufactured by injection moulding and their inspection is carried out after stabilization, around 200 hours. The overall goal of this work is to reach ±5μm in uncertainty measurements a polymer products which is a challenge in today`s production and metrology environments. The residual deformations in polymer products at room temperature after injection molding are important when micrometer accuracy needs to be achieved. Numerical modelling can give a valuable insight to what is happening in the polymer during cooling down after injection molding. In order to obtain accurate simulations, accurate inputs to the model are crucial. In reality however, the material and physical properties will have some variations. Although these variations may be small, they can act as a source of uncertainty for the measurement. In this paper, we investigated how big the variation in material and physical properties are allowed in order to reach the 5 μm target on the uncertainty.

  5. PETs: A Stable and Accurate Predictor of Protein-Protein Interacting Sites Based on Extremely-Randomized Trees.

    Science.gov (United States)

    Xia, Bin; Zhang, Hong; Li, Qianmu; Li, Tao

    2015-12-01

    Protein-protein interaction (PPI) plays crucial roles in the performance of various biological processes. A variety of methods are dedicated to identify whether proteins have interaction residues, but it is often more crucial to recognize each amino acid. In practical applications, the stability of a prediction model is as important as its accuracy. However, random sampling, which is widely used in previous prediction models, often brings large difference between each training model. In this paper, a Predictor of protein-protein interaction sites based on Extremely-randomized Trees (PETs) is proposed to improve the prediction accuracy while maintaining the prediction stability. In PETs, a cluster-based sampling strategy is proposed to ensure the model stability: first, the training dataset is divided into subsets using specific features; second, the subsets are clustered using K-means; and finally the samples are selected from each cluster. Using the proposed sampling strategy, samples which have different types of significant features could be selected independently from different clusters. The evaluation shows that PETs is able to achieve better accuracy while maintaining a good stability. The source code and toolkit are available at https://github.com/BinXia/PETs.

  6. Practical do-it-yourself device for accurate volume measurement of breast.

    Science.gov (United States)

    Tezel, E; Numanoğlu, A

    2000-03-01

    A simple and accurate method of measuring differences in breast volume based on Archimedes' principle is described. In this method, a plastic container is placed on the breast of the patient who is lying in supine position. While the breast occupies part of the container, the remaining part is filled with water and the volume is measured. This method allows the measurement of the volume differences of asymmetric breasts and also helps the surgeon to estimate the size of the prosthesis to be used in augmentation mammaplasty.

  7. Progress Toward Accurate Measurements of Power Consumptions of DBD Plasma Actuators

    Science.gov (United States)

    Ashpis, David E.; Laun, Matthew C.; Griebeler, Elmer L.

    2012-01-01

    The accurate measurement of power consumption by Dielectric Barrier Discharge (DBD) plasma actuators is a challenge due to the characteristics of the actuator current signal. Micro-discharges generate high-amplitude, high-frequency current spike transients superimposed on a low-amplitude, low-frequency current. We have used a high-speed digital oscilloscope to measure the actuator power consumption using the Shunt Resistor method and the Monitor Capacitor method. The measurements were performed simultaneously and compared to each other in a time-accurate manner. It was found that low signal-to-noise ratios of the oscilloscopes used, in combination with the high dynamic range of the current spikes, make the Shunt Resistor method inaccurate. An innovative, nonlinear signal compression circuit was applied to the actuator current signal and yielded excellent agreement between the two methods. The paper describes the issues and challenges associated with performing accurate power measurements. It provides insights into the two methods including new insight into the Lissajous curve of the Monitor Capacitor method. Extension to a broad range of parameters and further development of the compression hardware will be performed in future work.

  8. Fast, Simple and Accurate Handwritten Digit Classification by Training Shallow Neural Network Classifiers with the 'Extreme Learning Machine' Algorithm.

    Science.gov (United States)

    McDonnell, Mark D; Tissera, Migel D; Vladusich, Tony; van Schaik, André; Tapson, Jonathan

    2015-01-01

    Recent advances in training deep (multi-layer) architectures have inspired a renaissance in neural network use. For example, deep convolutional networks are becoming the default option for difficult tasks on large datasets, such as image and speech recognition. However, here we show that error rates below 1% on the MNIST handwritten digit benchmark can be replicated with shallow non-convolutional neural networks. This is achieved by training such networks using the 'Extreme Learning Machine' (ELM) approach, which also enables a very rapid training time (∼ 10 minutes). Adding distortions, as is common practise for MNIST, reduces error rates even further. Our methods are also shown to be capable of achieving less than 5.5% error rates on the NORB image database. To achieve these results, we introduce several enhancements to the standard ELM algorithm, which individually and in combination can significantly improve performance. The main innovation is to ensure each hidden-unit operates only on a randomly sized and positioned patch of each image. This form of random 'receptive field' sampling of the input ensures the input weight matrix is sparse, with about 90% of weights equal to zero. Furthermore, combining our methods with a small number of iterations of a single-batch backpropagation method can significantly reduce the number of hidden-units required to achieve a particular performance. Our close to state-of-the-art results for MNIST and NORB suggest that the ease of use and accuracy of the ELM algorithm for designing a single-hidden-layer neural network classifier should cause it to be given greater consideration either as a standalone method for simpler problems, or as the final classification stage in deep neural networks applied to more difficult problems.

  9. Fast, Simple and Accurate Handwritten Digit Classification by Training Shallow Neural Network Classifiers with the 'Extreme Learning Machine' Algorithm.

    Directory of Open Access Journals (Sweden)

    Mark D McDonnell

    Full Text Available Recent advances in training deep (multi-layer architectures have inspired a renaissance in neural network use. For example, deep convolutional networks are becoming the default option for difficult tasks on large datasets, such as image and speech recognition. However, here we show that error rates below 1% on the MNIST handwritten digit benchmark can be replicated with shallow non-convolutional neural networks. This is achieved by training such networks using the 'Extreme Learning Machine' (ELM approach, which also enables a very rapid training time (∼ 10 minutes. Adding distortions, as is common practise for MNIST, reduces error rates even further. Our methods are also shown to be capable of achieving less than 5.5% error rates on the NORB image database. To achieve these results, we introduce several enhancements to the standard ELM algorithm, which individually and in combination can significantly improve performance. The main innovation is to ensure each hidden-unit operates only on a randomly sized and positioned patch of each image. This form of random 'receptive field' sampling of the input ensures the input weight matrix is sparse, with about 90% of weights equal to zero. Furthermore, combining our methods with a small number of iterations of a single-batch backpropagation method can significantly reduce the number of hidden-units required to achieve a particular performance. Our close to state-of-the-art results for MNIST and NORB suggest that the ease of use and accuracy of the ELM algorithm for designing a single-hidden-layer neural network classifier should cause it to be given greater consideration either as a standalone method for simpler problems, or as the final classification stage in deep neural networks applied to more difficult problems.

  10. Precise and accurate measurements of strong-field photoionisation and a transferrable laser intensity calibration standard

    CERN Document Server

    Wallace, W C; Khurmi, C; U., Satya Sainadh; Calvert, J E; Laban, D E; Pullen, M G; Bartschat, K; Grum-Grzhimailo, A N; Wells, D; Quiney, H M; Tong, X M; Litvinyuk, I V; Sang, R T; Kielpinski, D

    2016-01-01

    Ionization of atoms and molecules in strong laser fields is a fundamental process in many fields of research, especially in the emerging field of attosecond science. So far, demonstrably accurate data have only been acquired for atomic hydrogen (H), a species that is accessible to few investigators. Here we present measurements of the ionization yield for argon, krypton, and xenon with percentlevel accuracy, calibrated using H, in a laser regime widely used in attosecond science. We derive a transferrable calibration standard for laser peak intensity, accurate to 1.3%, that is based on a simple reference curve. In addition, our measurements provide a much-needed benchmark for testing models of ionisation in noble-gas atoms, such as the widely employed single-active electron approximation.

  11. Accurate Estimation of Low Fundamental Frequencies from Real-Valued Measurements

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2013-01-01

    In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason for this is that the......In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason...... for this is that they employ asymptotic approximations that are violated when the harmonics are not well-separated in frequency, something that happens when the observed signal is real-valued and the fundamental frequency is low. To mitigate this, we analyze the problem and present some exact fundamental frequency estimators...

  12. Accurate microfour-point probe sheet resistance measurements on small samples

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Wang, Fei; Petersen, Dirch Hjorth

    2009-01-01

    We show that accurate sheet resistance measurements on small samples may be performed using microfour-point probes without applying correction factors. Using dual configuration measurements, the sheet resistance may be extracted with high accuracy when the microfour-point probes are in proximity...... with sufficient accuracy. As an example, the sheet resistance of a 40 µm (50 µm) square sample may be characterized with an accuracy of 0.3% (0.1%) using a 10 µm pitch microfour-point probe and assuming a probe alignment accuracy of ±2.5 µm. ©2009 American Institute of Physics...... of a mirror plane on small samples with dimensions of a few times the probe pitch. We calculate theoretically the size of the “sweet spot,” where sufficiently accurate sheet resistances result and show that even for very small samples it is feasible to do correction free extraction of the sheet resistance...

  13. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    Science.gov (United States)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  14. Accurate acoustic power measurement for low-intensity focused ultrasound using focal axial vibration velocity

    Science.gov (United States)

    Tao, Chenyang; Guo, Gepu; Ma, Qingyu; Tu, Juan; Zhang, Dong; Hu, Jimin

    2017-07-01

    Low-intensity focused ultrasound is a form of therapy that can have reversible acoustothermal effects on biological tissue, depending on the exposure parameters. The acoustic power (AP) should be chosen with caution for the sake of safety. To recover the energy of counteracted radial vibrations at the focal point, an accurate AP measurement method using the focal axial vibration velocity (FAVV) is proposed in explicit formulae and is demonstrated experimentally using a laser vibrometer. The experimental APs for two transducers agree well with theoretical calculations and numerical simulations, showing that AP is proportional to the square of the FAVV, with a fixed power gain determined by the physical parameters of the transducers. The favorable results suggest that the FAVV can be used as a valuable parameter for non-contact AP measurement, providing a new strategy for accurate power control for low-intensity focused ultrasound in biomedical engineering.

  15. Accurate potential drop sheet resistance measurements of laser-doped areas in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Heinrich, Martin, E-mail: mh.seris@gmail.com [Solar Energy Research Institute of Singapore, National University of Singapore, Singapore 117574 (Singapore); NUS Graduate School for Integrative Science and Engineering, National University of Singapore, Singapore 117456 (Singapore); Kluska, Sven; Binder, Sebastian [Fraunhofer Institute for Solar Energy Systems (ISE), Heidenhofstrasse 2, D-79110 Freiburg (Germany); Hameiri, Ziv [The School of Photovoltaic and Renewable Energy Engineering, The University of New South Wales, Sydney NSW 2052 (Australia); Hoex, Bram [Solar Energy Research Institute of Singapore, National University of Singapore, Singapore 117574 (Singapore); Aberle, Armin G. [Solar Energy Research Institute of Singapore, National University of Singapore, Singapore 117574 (Singapore); NUS Graduate School for Integrative Science and Engineering, National University of Singapore, Singapore 117456 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117456 (Singapore)

    2014-10-07

    It is investigated how potential drop sheet resistance measurements of areas formed by laser-assisted doping in crystalline Si wafers are affected by typically occurring experimental factors like sample size, inhomogeneities, surface roughness, or coatings. Measurements are obtained with a collinear four point probe setup and a modified transfer length measurement setup to measure sheet resistances of laser-doped lines. Inhomogeneities in doping depth are observed from scanning electron microscope images and electron beam induced current measurements. It is observed that influences from sample size, inhomogeneities, surface roughness, and coatings can be neglected if certain preconditions are met. Guidelines are given on how to obtain accurate potential drop sheet resistance measurements on laser-doped regions.

  16. Rapid accurate isotopic measurements on boron in boric acid and boron carbide.

    Science.gov (United States)

    Duchateau, N L; Verbruggen, A; Hendrickx, F; De Bièvre, P

    1986-04-01

    A procedure is described whereby rapid and accurate isotopic measurements can be performed on boron in boric acid and boron carbide after fusion of these compounds with calcium carbonate. It allows the determination of the isotopic composition of boron in boric acid and boron carbide and the direct assay of boron or the (10)B isotope in boron carbide by isotope-dilution mass spectrometry.

  17. A Novel Multimode Waveguide Coupler for Accurate Power Measurement of Traveling Wave Tube Harmonic Frequencies

    Science.gov (United States)

    Wintucky, Edwin G.; Simons, Rainee N.

    2014-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.

  18. Dilated Chi-Square : a novel interestingness measure to build accurate and compact decion list

    OpenAIRE

    Lan, Yu; Janssens, Davy; Chen, Guoqing; Wets, Geert

    2005-01-01

    Associative classification has aroused significant attention in recent years. This paper proposed a novel interestingness measure, named dilated chi-square, to statistically reveal the interdependence between the antecedents and the consequent of classificaton rules. Using dilated chi-square, instead of confidence, as the primary ranking criterion for rules under the framework of popular CBA algorithm, the adapted algorithm presented in this paper can empirically generate more accurate and mu...

  19. Precision and accuracy of 3D lower extremity residua measurement systems

    Science.gov (United States)

    Commean, Paul K.; Smith, Kirk E.; Vannier, Michael W.; Hildebolt, Charles F.; Pilgram, Thomas K.

    1996-04-01

    Accurate and reproducible geometric measurement of lower extremity residua is required for custom prosthetic socket design. We compared spiral x-ray computed tomography (SXCT) and 3D optical surface scanning (OSS) with caliper measurements and evaluated the precision and accuracy of each system. Spiral volumetric CT scanned surface and subsurface information was used to make external and internal measurements, and finite element models (FEMs). SXCT and OSS were used to measure lower limb residuum geometry of 13 below knee (BK) adult amputees. Six markers were placed on each subject's BK residuum and corresponding plaster casts and distance measurements were taken to determine precision and accuracy for each system. Solid models were created from spiral CT scan data sets with the prosthesis in situ under different loads using p-version finite element analysis (FEA). Tissue properties of the residuum were estimated iteratively and compared with values taken from the biomechanics literature. The OSS and SXCT measurements were precise within 1% in vivo and 0.5% on plaster casts, and accuracy was within 3.5% in vivo and 1% on plaster casts compared with caliper measures. Three-dimensional optical surface and SXCT imaging systems are feasible for capturing the comprehensive 3D surface geometry of BK residua, and provide distance measurements statistically equivalent to calipers. In addition, SXCT can readily distinguish internal soft tissue and bony structure of the residuum. FEM can be applied to determine tissue material properties interactively using inverse methods.

  20. Measurement of caudate nucleus area - a more accurate measurement for Huntington's disease

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, J.M.; Abernethy, L.J. (Royal Infirmary, London (United Kingdom). Dept. of Radiology); Sellar, R.J. (Western General Hospital, Edinburgh (United Kingdom). Dept. of Neuroradiology)

    1991-08-01

    Caudate nucleus atrophy occurs in Huntington's disease and methods of measuring this have been described using axial CT, but these are indirect and lack sensitivity. We measured caudate nucleus area (blind to the subjects' clinical state) in 30 subjects with or at risk of Huntington's disease, and in 100 normal age matched controls. Fifteen subjects with established symptomatic Huntington's disease, 3 with early symptoms, and 3 presymptomatic subjects (2 showing a high probability for the Huntington's disease gene on genetic testing, and one who has since developed symptoms) were correctly identified. Three normal (gene negative) family members were also correctly identified. Outcome is awaited in 6. CT caudate area measurement is simple and reproducible and we have found it to be a useful confirmatory test for Huntington's disease. (orig.).

  1. Accurate measurement of spatial noise portraits of photosensors of digital cameras

    Science.gov (United States)

    Cheremkhin, P. A.; Evtikhiev, N. N.; Krasnov, V. V.; Kulakov, M. N.; Starikov, R. S.

    2016-08-01

    Method of measurement of accurate portraits of light and dark spatial noise of photosensors is described. The method consists of four steps: creation of spatially homogeneous illumination; shooting light and dark frames; digital processing and filtering. Unlike standard technique, this method uses iterative creation of spatially homogeneous illumination by display, compensation of photosensor dark spatial noise portrait and improved procedure of elimination of dark temporal noise. Portraits of light and dark spatial noise of photosensors of a scientific digital camera were found. Characteristics of the measured portraits were compared with values of photo response and dark signal non-uniformities of camera's photosensor.

  2. High-resolution Sonographic Measurements of Lower Extremity Bursae in Chinese Healthy Young Men

    Directory of Open Access Journals (Sweden)

    Yong-Yan Gao

    2016-01-01

    Conclusions: Using HR-US imaging, we were able to analyze lower extremity bursae with high detection rates in healthy young men. The normal ranges of lower extremity bursa dimensions in healthy young men measured by HR-US in this study could be used as reference values for evaluation of bursa abnormalities in the lower extremity.

  3. Particle Image Velocimetry Measurements in Anatomically-Accurate Models of the Mammalian Nasal Cavity

    Science.gov (United States)

    Rumple, C.; Richter, J.; Craven, B. A.; Krane, M.

    2012-11-01

    A summary of the research being carried out by our multidisciplinary team to better understand the form and function of the nose in different mammalian species that include humans, carnivores, ungulates, rodents, and marine animals will be presented. The mammalian nose houses a convoluted airway labyrinth, where two hallmark features of mammals occur, endothermy and olfaction. Because of the complexity of the nasal cavity, the anatomy and function of these upper airways remain poorly understood in most mammals. However, recent advances in high-resolution medical imaging, computational modeling, and experimental flow measurement techniques are now permitting the study of airflow and respiratory and olfactory transport phenomena in anatomically-accurate reconstructions of the nasal cavity. Here, we focus on efforts to manufacture transparent, anatomically-accurate models for stereo particle image velocimetry (SPIV) measurements of nasal airflow. Challenges in the design and manufacture of index-matched anatomical models are addressed and preliminary SPIV measurements are presented. Such measurements will constitute a validation database for concurrent computational fluid dynamics (CFD) simulations of mammalian respiration and olfaction. Supported by the National Science Foundation.

  4. More accurate systolic blood pressure measurement is required for improved hypertension management: a perspective

    Directory of Open Access Journals (Sweden)

    Nitzan M

    2017-07-01

    Full Text Available Meir Nitzan,1 Itzchak Slotki,2 Linda Shavit2 1Department of Applied Physics/Electro-Optics, Jerusalem College of Technology, 2Department of Nephrology, Shaare Zedek Medical Center, Jerusalem, Israel Abstract: The commonly used techniques for systolic blood pressure (SBP and diastolic blood pressure (DBP measurement are the auscultatory Korotkoff-based sphygmomanometry and oscillometry. The former technique is relatively accurate but is limited to a physician’s office because its automatic variant is subject to noise artifacts. Consequently, the Korotkoff-based measurement overestimates the blood pressure in some patients due to white coat effect, and because it is a single measurement, it cannot properly represent the variable blood pressure. Automatic oscillometry can be used at home by the patient and is preferred even in clinics. However, the technique’s accuracy is low and errors of 10–15 mmHg are common. Recently, we have developed an automatic technique for SBP measurement, based on an arm pressure cuff and a finger photoplethysmographic probe. The technique was found to be significantly more accurate than oscillometry, and comparable to the Korotkoff-based technique, the reference-standard for non-invasive blood pressure measurements. The measurement of SBP is a mainstay for the diagnosis and follow-up of hypertension, which is a major risk factor for several adverse events, mainly cardiovascular. Lowering blood pressure evidently reduces the risk, but excessive lowering can result in hypotension and consequently hypoperfusion to vital organs, since blood pressure is the driving force for blood flow. Erroneous measurement by 10 mmHg can lead to a similar unintended reduction of SBP and may adversely affect patients treated to an SBP of 120–130 mmHg. In particular, in elderly patients, unintended excessive reduction of blood pressure due to inaccurate SBP measurement can result in cerebral hypoperfusion and consequent cognitive

  5. The road towards accurate optical width measurements at the industrial level

    Science.gov (United States)

    Bodermann, Bernd; Köning, Rainer; Bergmann, Detlef; Buhr, Egbert; Hässler-Grohne, Wolfgang; Flügge, Jens; Bosse, Harald

    2013-04-01

    Optical vision systems require both unidirectional and bidirectional measurements for the calibrations and the verification of the tool performance to enable accurate measurements traceable to the SI unit Metre. However, for bidirectional measurements up to now the national metrology institutes are unable to provide internationally recognized calibrations of suitable standards. Furthermore often users are not aware of the specific difficulties of these measurements. In this paper the current status and limitations of bidirectional optical measurements at the industrial level are summarised and compared to state-of-the-art optical linewidth measurements performed at PTB on measurement objects of semiconductor industry. It turns out, that for optical widths measurements at an uncertainty level below 1 μm edge localisation schemes are required, which are based on tool and sample dependent threshold values, which usually need to be determined by a rigorous simulation of the microscopic image. Furthermore the calibration samples and structures must have a sufficient quality, e. g. high edge angle and low edge roughness and the structure materials and their material parameters have to be known. The experience obtained within the accreditation process of industrial labs for width calibrations shows that, in order to be able to achieve a desired measurement uncertainties of about 100 nm, the imaging system needs to have a monochromatic Koehler illumination, numerical aperture larger than 0.5, a magnification greater than 50x and the ability to control the deviation of the focus position to better than 100 nm.

  6. Lower extremity angle measurement with accelerometers - error and sensitivity analysis

    NARCIS (Netherlands)

    Willemsen, Antoon Th.M.; Frigo, Carlo; Boom, Herman B.K.

    1991-01-01

    The use of accelerometers for angle assessment of the lower extremities is investigated. This method is evaluated by an error-and-sensitivity analysis using healthy subject data. Of three potential error sources (the reference system, the accelerometers, and the model assumptions) the last is found

  7. Combining MFD and PIE for accurate single-pair Förster resonance energy transfer measurements.

    Science.gov (United States)

    Kudryavtsev, Volodymyr; Sikor, Martin; Kalinin, Stanislav; Mokranjac, Dejana; Seidel, Claus A M; Lamb, Don C

    2012-03-01

    Single-pair Förster resonance energy transfer (spFRET) experiments using single-molecule burst analysis on a confocal microscope are an ideal tool to measure inter- and intramolecular distances and dynamics on the nanoscale. Different techniques have been developed to maximize the amount of information available in spFRET burst analysis experiments. Multiparameter fluorescence detection (MFD) is used to monitor a variety of fluorescence parameters simultaneously and pulsed interleaved excitation (PIE) employs direct excitation of the acceptor to probe its presence and photoactivity. To calculate accurate FRET efficiencies from spFRET experiments with MFD or PIE, several calibration measurements are usually required. Herein, we demonstrate that by combining MFD with PIE information regarding all calibration factors as well as an accurate determination of spFRET histograms can be performed in a single measurement. In addition, the quality of overlap of the different detection volumes as well as the detection of acceptor photophysics can be investigated with MFD-PIE. Bursts containing acceptor photobleaching can be identified and excluded from further investigation while bursts that contain FRET dynamics are unaffected by this analysis. We have employed MFD-PIE to accurately analyze the effects of nucleotides and substrate on the interdomain separation in DnaK, the major bacterial heat shock protein 70 (Hsp70). The interdomain distance increases from 47 Å in the ATP-bound state to 84 Å in the ADP-bound state and slightly contracts to 77 Å when a substrate is bound. This is in contrast to what was observed for the mitochondrial member of the Hsp70s, Ssc1, supporting the notion of evolutionary specialization of Hsp70s for different cellular functions in different organisms and cell organelles.

  8. A Flexible Fringe Projection Vision System with Extended Mathematical Model for Accurate Three-Dimensional Measurement

    Directory of Open Access Journals (Sweden)

    Suzhi Xiao

    2016-04-01

    Full Text Available In order to acquire an accurate three-dimensional (3D measurement, the traditional fringe projection technique applies complex and laborious procedures to compensate for the errors that exist in the vision system. However, the error sources in the vision system are very complex, such as lens distortion, lens defocus, and fringe pattern nonsinusoidality. Some errors cannot even be explained or rendered with clear expressions and are difficult to compensate directly as a result. In this paper, an approach is proposed that avoids the complex and laborious compensation procedure for error sources but still promises accurate 3D measurement. It is realized by the mathematical model extension technique. The parameters of the extended mathematical model for the ’phase to 3D coordinates transformation’ are derived using the least-squares parameter estimation algorithm. In addition, a phase-coding method based on a frequency analysis is proposed for the absolute phase map retrieval to spatially isolated objects. The results demonstrate the validity and the accuracy of the proposed flexible fringe projection vision system on spatially continuous and discontinuous objects for 3D measurement.

  9. Designer cantilevers for even more accurate quantitative measurements of biological systems with multifrequency AFM

    Science.gov (United States)

    Contera, S.

    2016-04-01

    Multifrequency excitation/monitoring of cantilevers has made it possible both to achieve fast, relatively simple, nanometre-resolution quantitative mapping of mechanical of biological systems in solution using atomic force microscopy (AFM), and single molecule resolution detection by nanomechanical biosensors. A recent paper by Penedo et al [2015 Nanotechnology 26 485706] has made a significant contribution by developing simple methods to improve the signal to noise ratio in liquid environments, by selectively enhancing cantilever modes, which will lead to even more accurate quantitative measurements.

  10. Ocean Lidar Measurements of Beam Attenuation and a Roadmap to Accurate Phytoplankton Biomass Estimates

    Science.gov (United States)

    Hu, Yongxiang; Behrenfeld, Mike; Hostetler, Chris; Pelon, Jacques; Trepte, Charles; Hair, John; Slade, Wayne; Cetinic, Ivona; Vaughan, Mark; Lu, Xiaomei; Zhai, Pengwang; Weimer, Carl; Winker, David; Verhappen, Carolus C.; Butler, Carolyn; Liu, Zhaoyan; Hunt, Bill; Omar, Ali; Rodier, Sharon; Lifermann, Anne; Josset, Damien; Hou, Weilin; MacDonnell, David; Rhew, Ray

    2016-06-01

    Beam attenuation coefficient, c, provides an important optical index of plankton standing stocks, such as phytoplankton biomass and total particulate carbon concentration. Unfortunately, c has proven difficult to quantify through remote sensing. Here, we introduce an innovative approach for estimating c using lidar depolarization measurements and diffuse attenuation coefficients from ocean color products or lidar measurements of Brillouin scattering. The new approach is based on a theoretical formula established from Monte Carlo simulations that links the depolarization ratio of sea water to the ratio of diffuse attenuation Kd and beam attenuation C (i.e., a multiple scattering factor). On July 17, 2014, the CALIPSO satellite was tilted 30° off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL) data that are collocated with in-water optical measurements.

  11. Accurate Measurement of the in vivo Ammonium Concentration in Saccharomyces cerevisiae

    Directory of Open Access Journals (Sweden)

    Hugo F. Cueto-Rojas

    2016-04-01

    Full Text Available Ammonium (NH4+ is the most common N-source for yeast fermentations, and N-limitation is frequently applied to reduce growth and increase product yields. While there is significant molecular knowledge on NH4+ transport and assimilation, there have been few attempts to measure the in vivo concentration of this metabolite. In this article, we present a sensitive and accurate analytical method to quantify the in vivo intracellular ammonium concentration in Saccharomyces cerevisiae based on standard rapid sampling and metabolomics techniques. The method validation experiments required the development of a proper sample processing protocol to minimize ammonium production/consumption during biomass extraction by assessing the impact of amino acid degradation—an element that is often overlooked. The resulting cold chloroform metabolite extraction method, together with quantification using ultra high performance liquid chromatography-isotope dilution mass spectrometry (UHPLC-IDMS, was not only more sensitive than most of the existing methods but also more accurate than methods that use electrodes, enzymatic reactions, or boiling water or boiling ethanol biomass extraction because it minimized ammonium consumption/production during sampling processing and interference from other metabolites in the quantification of intracellular ammonium. Finally, our validation experiments showed that other metabolites such as pyruvate or 2-oxoglutarate (αKG need to be extracted with cold chloroform to avoid measurements being biased by the degradation of other metabolites (e.g., amino acids.

  12. Accurate Measurement of the in vivo Ammonium Concentration in Saccharomyces cerevisiae.

    Science.gov (United States)

    Cueto-Rojas, Hugo F; Maleki Seifar, Reza; Ten Pierick, Angela; Heijnen, Sef J; Wahl, Aljoscha

    2016-04-23

    Ammonium (NH₄⁺) is the most common N-source for yeast fermentations, and N-limitation is frequently applied to reduce growth and increase product yields. While there is significant molecular knowledge on NH₄⁺ transport and assimilation, there have been few attempts to measure the in vivo concentration of this metabolite. In this article, we present a sensitive and accurate analytical method to quantify the in vivo intracellular ammonium concentration in Saccharomyces cerevisiae based on standard rapid sampling and metabolomics techniques. The method validation experiments required the development of a proper sample processing protocol to minimize ammonium production/consumption during biomass extraction by assessing the impact of amino acid degradation-an element that is often overlooked. The resulting cold chloroform metabolite extraction method, together with quantification using ultra high performance liquid chromatography-isotope dilution mass spectrometry (UHPLC-IDMS), was not only more sensitive than most of the existing methods but also more accurate than methods that use electrodes, enzymatic reactions, or boiling water or boiling ethanol biomass extraction because it minimized ammonium consumption/production during sampling processing and interference from other metabolites in the quantification of intracellular ammonium. Finally, our validation experiments showed that other metabolites such as pyruvate or 2-oxoglutarate (αKG) need to be extracted with cold chloroform to avoid measurements being biased by the degradation of other metabolites (e.g., amino acids).

  13. Rapid and accurate biofuel moisture content gauging using magnetic resonance measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Jaervinen, T.

    2013-04-15

    Biomass is extensively utilised in energy production and as a raw material, such as for the production of liquid biofuels. All those processes will benefit if the moisture content of bio material is known in advance as accurately as possible under transient circumstances. Biofuel trade is increasingly based on the calorific value of fuels. In the first step, this also increases the need for rapid and accurate moisture content determination. During the last few years, large biofuel standardisation has been implemented, emphasising biofuel quality control at all stages of the utilisation chain. In principle, the moisture instrumental measurement can be utilised by many technologies and procedures. Typical techniques are infrared, radiofrequency, microwave, radiometric, electrical conductivity, capacitance, and impedance. Nuclear magnetic resonance (MR) and thermal neutron absorption are also applied. The MR measurement principle has been known and utilised already since the early 1950s. It has become the basic instrumental analysis tool in chemistry. It is also well-known as a very accurate method for analysing most compounds, especially substances containing hydrogen. The utilisation of MR metering is expanded extensively to medical diagnostics as a form of magnetic resonance imaging (MRI). Because of the precision of the MR principle, there have for a long time been efforts to apply it in new and different areas, and to make more user-friendly, smaller, and even portable devices. Such a device was designed by Vaisala a few years ago. VTT has utilised Vaisala's MR prototype for approximately one year for moisture content measurement of different biofuels. The first step in the use of an MR device for moisture determination was the definition of its measurement accuracy compared to the standard method (EN 14774). Those tests proved that the absolute precision seems to be comparable to the standard moisture content measurement method. It was also found out that

  14. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    Science.gov (United States)

    Krimi, Soufiene; Klier, Jens; Jonuscheit, Joachim; von Freymann, Georg; Urbansky, Ralph; Beigang, René

    2016-07-01

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

  15. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  16. Apparatus for accurate density measurements of fluids based on a magnetic suspension balance

    Science.gov (United States)

    Gong, Maoqiong; Li, Huiya; Guo, Hao; Dong, Xueqiang; Wu, J. F.

    2012-06-01

    A new apparatus for accurate pressure, density and temperature (p, ρ, T) measurements over wide ranges of (p, ρ, T) (90 K to 290 K; 0 MPa to 3 MPa; 0 kg/m3 to 2000 kg/m3) is described. This apparatus is based on a magnetic suspension balance which applies the Archimedes' buoyancy principle. In order to verify the new apparatus, comprehensive (p, ρ, T) measurements on pure nitrogen were carried out. The maximum relative standard uncertainty is 0.09% in density. The maximum standard uncertainty in temperature is 5 mK, and that in pressure is 250 Pa for 1.5 MPa and 390 Pa for 3MPa full scale range respectively. The experimental data were compared with selected literature data and good agreements were found.

  17. Importance of Accurate Measurements in Nutrition Research: Dietary Flavonoids as a Case Study.

    Science.gov (United States)

    Harnly, James

    2016-03-01

    Accurate measurements of the secondary metabolites in natural products and plant foods are critical for establishing relations between diet and health. There are as many as 50,000 secondary metabolites that may influence human health. Their structural and chemical diversity presents a challenge to analytical chemistry. With respect to flavonoids, putative identification is accessible, but positive identification and quantification are limited by the lack of standards. Quantification has been tested with use of both nonspecific and specific methods. Nonspecific methods, which include antioxidant capacity methods, fail to provide information on the measured components, suffer from numerous interferences, are not equatable, and are unsuitable for health research. Specific methods, such as LC with diode array and mass spectrometric detection, require the use of internal standards and relative molar response factors. These methods are relatively expensive and require a high level of expertise and experimental verification; however, they represent the only suitable means of relating health outcomes to specific dietary components.

  18. A solution for measuring accurate reaction time to visual stimuli realized with a programmable microcontroller.

    Science.gov (United States)

    Ohyanagi, Toshio; Sengoku, Yasuhito

    2010-02-01

    This article presents a new solution for measuring accurate reaction time (SMART) to visual stimuli. The SMART is a USB device realized with a Cypress Programmable System-on-Chip (PSoC) mixed-signal array programmable microcontroller. A brief overview of the hardware and firmware of the PSoC is provided, together with the results of three experiments. In Experiment 1, we investigated the timing accuracy of the SMART in measuring reaction time (RT) under different conditions of operating systems (OSs; Windows XP or Vista) and monitor displays (a CRT or an LCD). The results indicated that the timing error in measuring RT by the SMART was less than 2 msec, on average, under all combinations of OS and display and that the SMART was tolerant to jitter and noise. In Experiment 2, we tested the SMART with 8 participants. The results indicated that there was no significant difference among RTs obtained with the SMART under the different conditions of OS and display. In Experiment 3, we used Microsoft (MS) PowerPoint to present visual stimuli on the display. We found no significant difference in RTs obtained using MS DirectX technology versus using the PowerPoint file with the SMART. We are certain that the SMART is a simple and practical solution for measuring RTs accurately. Although there are some restrictions in using the SMART with RT paradigms, the SMART is capable of providing both researchers and health professionals working in clinical settings with new ways of using RT paradigms in their work.

  19. Unexpected Advantages Of Less Accurate Performance Measurements : How simple prescription data control the use of drugs in a complex setting

    NARCIS (Netherlands)

    A.A. de Bont (Antoinette); K.J. Grit (Kor)

    2010-01-01

    textabstractIn this paper we argue that performance measurement can better be done by general, less accurate measurements than by complex – and possible more accurate - ones. The conclusions of this study are drawn from a case study of the Dutch Foundation for effective use of medication. While most

  20. An affordable and accurate conductivity probe for density measurements in stratified flows

    Science.gov (United States)

    Carminati, Marco; Luzzatto-Fegiz, Paolo

    2015-11-01

    In stratified flow experiments, conductivity (combined with temperature) is often used to measure density. The probes typically used can provide very fine spatial scales, but can be fragile, expensive to replace, and sensitive to environmental noise. A complementary instrument, comprising a low-cost conductivity probe, would prove valuable in a wide range of applications where resolving extremely small spatial scales is not needed. We propose using micro-USB cables as the actual conductivity sensors. By removing the metallic shield from a micro-B connector, 5 gold-plated microelectrodes are exposed and available for 4-wire measurements. These have a cell constant ~550m-1, an intrinsic thermal noise of at most 30pA/Hz1/2, as well as sub-millisecond time response, making them highly suitable for many stratified flow measurements. In addition, we present the design of a custom electronic board (Arduino-based and Matlab-controlled) for simultaneous acquisition from 4 sensors, with resolution (in conductivity, and resulting density) exceeding the performance of typical existing probes. We illustrate the use of our conductivity-measuring system through stratified flow experiments, and describe plans to release simple instructions to construct our complete system for around 200.

  1. Smart density: a more accurate method of measuring rural residential density for health-related research

    Directory of Open Access Journals (Sweden)

    Gibson Lucinda

    2010-02-01

    Full Text Available Abstract Background Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. Objective We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. Methods We compared residential density (units/acre in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block with two GIS buffer measures: a 1-kilometer (km circle around the school and a 1-km circle intersected with a 100-meter (m road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Results Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Conclusion Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  2. Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement

    Science.gov (United States)

    Li, Yafeng; Zhang, Ning; Zhou, Yueming; Wang, Jianing; Zhang, Yiming; Wang, Jiyun; Xiong, Caiqiao; Chen, Suming; Nie, Zongxiu

    2013-09-01

    Accurate mass information is of great importance in the determination of unknown compounds. An effective and easy-to-control internal mass calibration method will dramatically benefit accurate mass measurement. Here we reported a simple induced dual-nanospray internal calibration device which has the following three advantages: (1) the two sprayers are in the same alternating current field; thus both reference ions and sample ions can be simultaneously generated and recorded. (2) It is very simple and can be easily assembled. Just two metal tubes, two nanosprayers, and an alternating current power supply are included. (3) With the low-flow-rate character and the versatility of nanoESI, this calibration method is capable of calibrating various samples, even untreated complex samples such as urine and other biological samples with small sample volumes. The calibration errors are around 1 ppm in positive ion mode and 3 ppm in negative ion mode with good repeatability. This new internal calibration method opens up new possibilities in the determination of unknown compounds, and it has great potential for the broad applications in biological and chemical analysis.

  3. Measuring nonlinear oscillations using a very accurate and low-cost linear optical position transducer

    Science.gov (United States)

    Donoso, Guillermo; Ladera, Celso L.

    2016-09-01

    An accurate linear optical displacement transducer of about 0.2 mm resolution over a range of ∼40 mm is presented. This device consists of a stack of thin cellulose acetate strips, each strip longitudinally slid ∼0.5 mm over the precedent one so that one end of the stack becomes a stepped wedge of constant step. A narrowed light beam from a white LED orthogonally incident crosses the wedge at a known point, the transmitted intensity being detected with a phototransistor whose emitter is connected to a diode. We present the interesting analytical proof that the voltage across the diode is linearly dependent upon the ordinate of the point where the light beam falls on the wedge, as well as the experimental validation of such a theoretical proof. Applications to nonlinear oscillations are then presented—including the interesting case of a body moving under dry friction, and the more advanced case of an oscillator in a quartic energy potential—whose time-varying positions were accurately measured with our transducer. Our sensing device can resolve the dynamics of an object attached to it with great accuracy and precision at a cost considerably less than that of a linear neutral density wedge. The technique used to assemble the wedge of acetate strips is described.

  4. Accurate Measurement of the Effects of All Amino-Acid Mutations on Influenza Hemagglutinin

    Directory of Open Access Journals (Sweden)

    Michael B. Doud

    2016-06-01

    Full Text Available Influenza genes evolve mostly via point mutations, and so knowing the effect of every amino-acid mutation provides information about evolutionary paths available to the virus. We and others have combined high-throughput mutagenesis with deep sequencing to estimate the effects of large numbers of mutations to influenza genes. However, these measurements have suffered from substantial experimental noise due to a variety of technical problems, the most prominent of which is bottlenecking during the generation of mutant viruses from plasmids. Here we describe advances that ameliorate these problems, enabling us to measure with greatly improved accuracy and reproducibility the effects of all amino-acid mutations to an H1 influenza hemagglutinin on viral replication in cell culture. The largest improvements come from using a helper virus to reduce bottlenecks when generating viruses from plasmids. Our measurements confirm at much higher resolution the results of previous studies suggesting that antigenic sites on the globular head of hemagglutinin are highly tolerant of mutations. We also show that other regions of hemagglutinin—including the stalk epitopes targeted by broadly neutralizing antibodies—have a much lower inherent capacity to tolerate point mutations. The ability to accurately measure the effects of all influenza mutations should enhance efforts to understand and predict viral evolution.

  5. Accurate laser measurements of ozone absorption cross-sections in the Hartley band

    Directory of Open Access Journals (Sweden)

    J. Viallon

    2014-08-01

    Full Text Available Ozone plays a crucial role in tropospheric chemistry, is the third largest contributor to greenhouse radiative forcing after carbon dioxide and methane and also a toxic air pollutant affecting human health and agriculture. Long-term measurements of tropospheric ozone have been performed globally for more than 30 years with UV photometers, all relying on the absorption of ozone at the 253.65 nm line of mercury. We have re-determined this cross-section and report a value of 11.27 × 10−18 cm2 molecule−1 with an expanded relative uncertainty of 0.84 %. This is lower than the conventional value currently in use and measured by Hearn in 1961 with a relative difference of 1.8%, with the consequence that historically reported ozone concentrations should be increased by 1.8%. In order to perform the new measurements of cross sections with reduced uncertainties, a system to generate pure ozone in the gas phase together with an optical system based on a UV laser with lines in the Hartley band, including accurate path length measurement of the absorption cell and a careful evaluation of possible impurities in the ozone sample by mass spectrometry and Fourier Transform Infrared spectroscopy was setup. This resulted in new measurements of absolute values of ozone absorption cross sections of 9.48 × 10−18, 10.44 × 10−18, and 11.07 × 10−18 cm2 molecule−1, with relative expanded uncertainties better than 0.6%, for the wavelengths (in vacuum of 244.062, 248.32, and 257.34 nm respectively. The cross-section at the 253.65 nm line of mercury was determined by comparisons using a Standard Reference Photometer equipped with a mercury lamp as the light source. The newly reported value should be used in the future to obtain the most accurate measurements of ozone concentration, which are in closer agreement with non UV photometry based methods such as the gas phase titration of ozone with nitrogen monoxide.

  6. Accurate measurements of ozone absorption cross-sections in the Hartley band

    Science.gov (United States)

    Viallon, J.; Lee, S.; Moussay, P.; Tworek, K.; Petersen, M.; Wielgosz, R. I.

    2015-03-01

    Ozone plays a crucial role in tropospheric chemistry, is the third largest contributor to greenhouse radiative forcing after carbon dioxide and methane and also a toxic air pollutant affecting human health and agriculture. Long-term measurements of tropospheric ozone have been performed globally for more than 30 years with UV photometers, all relying on the absorption of ozone at the 253.65 nm line of mercury. We have re-determined this cross-section and report a value of 11.27 x 10-18 cm2 molecule-1 with an expanded relative uncertainty of 0.86% (coverage factor k= 2). This is lower than the conventional value currently in use and measured by Hearn (1961) with a relative difference of 1.8%, with the consequence that historically reported ozone concentrations should be increased by 1.8%. In order to perform the new measurements of cross-sections with reduced uncertainties, a system was set up to generate pure ozone in the gas phase together with an optical system based on a UV laser with lines in the Hartley band, including accurate path length measurement of the absorption cell and a careful evaluation of possible impurities in the ozone sample by mass spectrometry and Fourier transform infrared spectroscopy. This resulted in new measurements of absolute values of ozone absorption cross-sections of 9.48 x 10-18, 10.44 x 10-18 and 11.07 x 10-18 cm2 molecule-1, with relative expanded uncertainties better than 0.7%, for the wavelengths (in vacuum) of 244.06, 248.32, and 257.34 nm respectively. The cross-section at the 253.65 nm line of mercury was determined by comparisons using a Standard Reference Photometer equipped with a mercury lamp as the light source. The newly reported value should be used in the future to obtain the most accurate measurements of ozone concentration, which are in closer agreement with non-UV-photometry based methods such as the gas phase titration of ozone with nitrogen monoxide.

  7. Accurate laser measurements of ozone absorption cross-sections in the Hartley band

    Science.gov (United States)

    Viallon, J.; Lee, S.; Moussay, P.; Tworek, K.; Petersen, M.; Wielgosz, R. I.

    2014-08-01

    Ozone plays a crucial role in tropospheric chemistry, is the third largest contributor to greenhouse radiative forcing after carbon dioxide and methane and also a toxic air pollutant affecting human health and agriculture. Long-term measurements of tropospheric ozone have been performed globally for more than 30 years with UV photometers, all relying on the absorption of ozone at the 253.65 nm line of mercury. We have re-determined this cross-section and report a value of 11.27 × 10-18 cm2 molecule-1 with an expanded relative uncertainty of 0.84 %. This is lower than the conventional value currently in use and measured by Hearn in 1961 with a relative difference of 1.8%, with the consequence that historically reported ozone concentrations should be increased by 1.8%. In order to perform the new measurements of cross sections with reduced uncertainties, a system to generate pure ozone in the gas phase together with an optical system based on a UV laser with lines in the Hartley band, including accurate path length measurement of the absorption cell and a careful evaluation of possible impurities in the ozone sample by mass spectrometry and Fourier Transform Infrared spectroscopy was setup. This resulted in new measurements of absolute values of ozone absorption cross sections of 9.48 × 10-18, 10.44 × 10-18, and 11.07 × 10-18 cm2 molecule-1, with relative expanded uncertainties better than 0.6%, for the wavelengths (in vacuum) of 244.062, 248.32, and 257.34 nm respectively. The cross-section at the 253.65 nm line of mercury was determined by comparisons using a Standard Reference Photometer equipped with a mercury lamp as the light source. The newly reported value should be used in the future to obtain the most accurate measurements of ozone concentration, which are in closer agreement with non UV photometry based methods such as the gas phase titration of ozone with nitrogen monoxide.

  8. Extremal Entangled Four-Qubit Pure States with Respect to Multiple Entropy Measures

    Institute of Scientific and Technical Information of China (English)

    GUO Ying; LIU Dan; ZENG Gui-Hua; ZHAO Xin; Moon Ho Lee; LONG Gui-Lu

    2008-01-01

    Four-qubit entanglement has been investigated using a recent proposed entanglement measure, multiple entropy measures (MEMS). We have performed optimization for the nine different families of states of four-qubit system. Some extremal entangled states have been found.

  9. Doppler broadening thermometry of acetylene and accurate measurement of the Boltzmann constant.

    Science.gov (United States)

    Hashemi, R; Povey, C; Derksen, M; Naseri, H; Garber, J; Predoi-Cross, A

    2014-12-07

    In this paper, we present accurate measurements of the fundamental Boltzmann constant based on a line-shape analysis of acetylene spectra in the ν1 + ν3 band recorded using a tunable diode laser. Experimental spectra recorded at low pressures (0.25 - 9 Torr), have been analyzed using a Speed Dependent Voigt model that takes into account the molecular speed dependence effects. This line-shape model reproduces the experimental data with good accuracy and allows us to determine precise line-shape parameters for the P(25) transition of the ν1 + ν3 band. From the recorded spectra we obtained the Doppler-width and then determined the Boltzmann constant, k(B).

  10. Accurate periodicity measurement of superconducting quantum interference device magnetic flux response.

    Science.gov (United States)

    Nakanishi, Masakazu

    2010-09-01

    It is theoretically explained that a response of a superconducting quantum interference device (SQUID) is periodically dependent on total magnetic flux coupling to the SQUID ring (Φ) and its period is a flux quantum (Φ(o)=h/2e, where h and e, respectively, express Planck's constant and elementary charge). For example, the voltage of an electromagnetically oscillated rf-SQUID or a current biased dc-SQUID is thought to be periodically dependent on Φ with a period of Φ(o). In this paper, we propose an accurate method to check the periodicity of a SQUID response by using a set of sensing coils covered with a superconducting sheath. As a demonstration, we measured periodicity of a commercially available thin-film type rf-SQUID response in magnetic flux ranging up to approximately 4300Φ(o). Its flux dependence was periodic below about 3400Φ(o).

  11. Measuring solar reflectance Part I: Defining a metric that accurately predicts solar heat gain

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Berdahl, Paul

    2010-05-14

    Solar reflectance can vary with the spectral and angular distributions of incident sunlight, which in turn depend on surface orientation, solar position and atmospheric conditions. A widely used solar reflectance metric based on the ASTM Standard E891 beam-normal solar spectral irradiance underestimates the solar heat gain of a spectrally selective 'cool colored' surface because this irradiance contains a greater fraction of near-infrared light than typically found in ordinary (unconcentrated) global sunlight. At mainland U.S. latitudes, this metric RE891BN can underestimate the annual peak solar heat gain of a typical roof or pavement (slope {le} 5:12 [23{sup o}]) by as much as 89 W m{sup -2}, and underestimate its peak surface temperature by up to 5 K. Using R{sub E891BN} to characterize roofs in a building energy simulation can exaggerate the economic value N of annual cool-roof net energy savings by as much as 23%. We define clear-sky air mass one global horizontal ('AM1GH') solar reflectance R{sub g,0}, a simple and easily measured property that more accurately predicts solar heat gain. R{sub g,0} predicts the annual peak solar heat gain of a roof or pavement to within 2 W m{sup -2}, and overestimates N by no more than 3%. R{sub g,0} is well suited to rating the solar reflectances of roofs, pavements and walls. We show in Part II that R{sub g,0} can be easily and accurately measured with a pyranometer, a solar spectrophotometer or version 6 of the Solar Spectrum Reflectometer.

  12. An algorithm for selecting the most accurate protocol for contact angle measurement by drop shape analysis.

    Science.gov (United States)

    Xu, Z N

    2014-12-01

    In this study, an error analysis is performed to study real water drop images and the corresponding numerically generated water drop profiles for three widely used static contact angle algorithms: the circle- and ellipse-fitting algorithms and the axisymmetric drop shape analysis-profile (ADSA-P) algorithm. The results demonstrate the accuracy of the numerically generated drop profiles based on the Laplace equation. A significant number of water drop profiles with different volumes, contact angles, and noise levels are generated, and the influences of the three factors on the accuracies of the three algorithms are systematically investigated. The results reveal that the above-mentioned three algorithms are complementary. In fact, the circle- and ellipse-fitting algorithms show low errors and are highly resistant to noise for water drops with small/medium volumes and contact angles, while for water drop with large volumes and contact angles just the ADSA-P algorithm can meet accuracy requirement. However, this algorithm introduces significant errors in the case of small volumes and contact angles because of its high sensitivity to noise. The critical water drop volumes of the circle- and ellipse-fitting algorithms corresponding to a certain contact angle error are obtained through a significant amount of computation. To improve the precision of the static contact angle measurement, a more accurate algorithm based on a combination of the three algorithms is proposed. Following a systematic investigation, the algorithm selection rule is described in detail, while maintaining the advantages of the three algorithms and overcoming their deficiencies. In general, static contact angles over the entire hydrophobicity range can be accurately evaluated using the proposed algorithm. The ease of erroneous judgment in static contact angle measurements is avoided. The proposed algorithm is validated by a static contact angle evaluation of real and numerically generated water drop

  13. An Accurate Method for Measuring Airplane-Borne Conformal Antenna's Radar Cross Section

    Science.gov (United States)

    Guo, Shuxia; Zhang, Lei; Wang, Yafeng; Hu, Chufeng

    2016-09-01

    The airplane-borne conformal antenna attaches itself tightly with the airplane skin, so the conventional measurement method cannot determine the contribution of the airplane-borne conformal antenna to its radar cross section (RCS). This paper uses the 2D microwave imaging to isolate and extract the distribution of the reflectivity of the airplane-borne conformal antenna. It obtains the 2D spatial spectra of the conformal antenna through the wave spectral transform between the 2D spatial image and the 2D spatial spectrum. After the interpolation from the rectangular coordinate domain to the polar coordinate domain, the spectral domain data for the variation of the scatter of the conformal antenna with frequency and angle is obtained. The experimental results show that the measurement method proposed in this paper greatly enhances the airplane-borne conformal antenna's RCS measurement accuracy, essentially eliminates the influences caused by the airplane skin and more accurately reveals the airplane-borne conformal antenna's RCS scatter properties.

  14. Rapid and accurate measurement of the frequency-frequency correlation function.

    Science.gov (United States)

    Osborne, Derek G; Kubarych, Kevin J

    2013-07-25

    Using an implementation of heterodyne-detected vibrational echo spectroscopy, we show that equilibrium spectral diffusion caused by solvation dynamics can be measured in a fraction of the time required using traditional two-dimensional infrared spectroscopy. Spectrally resolved, heterodyne-detected rephasing and nonrephasing signals, recorded at a single delay between the first two pulses in a photon echo sequence, can be used to measure the full waiting time dependent spectral dynamics that are typically extracted from a series of 2D-IR spectra. Hence, data acquisition is accelerated by more than 1 order of magnitude, while permitting extremely fine sampling of the spectral dynamics during the waiting time between the second and third pulses. Using cymantrene (cyclopentadienyl manganese tricarbonyl, CpMn(CO)3) in alcohol solutions, we compare this novel approach--denoted rapidly acquired spectral diffusion (RASD)--with a traditional method using full 2D-IR spectra, finding excellent agreement. Though this approach is largely limited to isolated vibrational bands, we also show how to remove interference from cross-peaks that can produce characteristic modulations of the spectral dynamics through vibrational quantum beats.

  15. Artificial absorption creation for more accurate tunable diode laser absorption spectroscopy measurement

    Science.gov (United States)

    Wei, Wei; Chang, Jun; Cao, Lihua; Liu, Yuanyuan; Chen, Xi; Zhu, Cunguang; Qin, Zengguang

    2017-09-01

    A novel strategy for more accurate tunable diode laser absorption spectroscopy (TDLAS) measurement is presented. This method is immune to non-absorption transmission losses, and allows dead zone removal for ultra-low concentration detection, and reference point selection at atmospheric pressure. The method adjusts laser emission and creates artificial absorption peaks according to requirements. By creating an artificial absorption peak next to the real absorption zone, calibration is not necessary. The developed method can be applied to not only wavelength modulation spectroscopy (WMS) but also direct absorption (DA). In WMS, the method does not need two harmonic signals, resulting in higher reliability, better performance, and no electro-optical gain uncertainty. At the same time, non-absorption transmission losses effect is suppressed from 70% to 0.425% with DA and from 70% to 0.225% with WMS method. When the artificial absorption peak coincides with the real one, the dead zone of measurement can be removed to give a lower detection limit, and water vapor still can be detected when concentration is lower than 0.2 ppm in our experiment. Reference point selection uncertainty with the DA method, especially when the signal-to-noise ratio is low and absorption line is broad, can also be facilitated. And the uncertainty of reference point selection is improved from 6% to 0.8% by measuring reference point amplitude. The method is demonstrated and validated by WMS and DA measurements of water vapor (1 atm, 296 K, 1368.597 nm). The measurement results obtained using the new method reveal its promise in TDLAS.

  16. Extreme-ultraviolet collector mirror measurement using large reflectometer at NewSUBARU synchrotron facility

    Science.gov (United States)

    Iguchi, Haruki; Hashimoto, Hiraku; Kuki, Masaki; Harada, Tetsuo; Kinoshita, Hiroo; Watanabe, Takeo; Platonov, Yuriy Y.; Kriese, Michael D.; Rodriguez, Jim R.

    2016-06-01

    In extreme-ultraviolet (EUV) lithography, the development of high-power EUV sources is one of the critical issues. The EUV output power directly depends on the collector mirror performance. Furthermore, mirrors with large diameters are necessary to achieve high collecting performance and take sufficient distance to prevent heat and debris from a radiation point of the source. Thus collector mirror development with accurate reflectometer is important. We have developed a large reflectometer at BL-10 beamline of the NewSUBARU synchrotron facility that can be used for mirrors with diameters, thicknesses, and weights of up to 800 mm, 250 mm, and 50 kg, respectively. This reflectometer can measure reflectivity with fully s-polarized EUV light. In this study, we measured the reflectance of a 412-mm-diameter EUV collector mirror using a maximum incident angle of 36°. We obtained the peak reflectance, center wavelength and reflection bandwidth results and compared our results with Physikalisch-Technische Bundesanstalt results.

  17. Extremely high-frequency micro-Doppler measurements of humans

    Science.gov (United States)

    Hedden, Abigail S.; Silvious, Jerry L.; Dietlein, Charles R.; Green, Jeremy A.; Wikner, David A.

    2014-05-01

    The development of sensors that are capable of penetrating smoke, dust, fog, clouds, and rain is critical for maintaining situational awareness in degraded visual environments and for providing support to the Warfighter. Atmospheric penetration properties, the ability to form high-resolution imagery with modest apertures, and available source power make the extremely high-frequency (EHF) portion of the spectrum promising for the development of radio frequency (RF) sensors capable of penetrating visual obscurants. Comprehensive phenomenology studies including polarization and backscatter properties of relevant targets are lacking at these frequencies. The Army Research Laboratory (ARL) is developing a fully-polarimetric frequency-modulated continuous-wave (FMCW) instrumentation radar to explore polarization and backscatter properties of in-situ rain, scattering from natural and man-made surfaces, and the radar cross section and micro-Doppler signatures of humans at EHF frequencies, specifically, around the 220 GHz atmospheric window. This work presents an overview of the design and construction of the radar system, hardware performance, data acquisition software, and initial results including an analysis of human micro-Doppler signatures.

  18. Accurate, in vivo NIR measurement of skeletal muscle oxygenation through fat

    Science.gov (United States)

    Jin, Chunguang; Zou, Fengmei; Ellerby, Gwenn E. C.; Scott, Peter; Peshlov, Boyan; Soller, Babs R.

    2010-02-01

    Noninvasive near infrared (NIR) spectroscopic measurement of muscle oxygenation requires the penetration of light through overlying skin and fat layers. We have previously demonstrated a dual-light source design and orthogonalization algorithm that corrects for inference from skin absorption and fat scattering. To achieve accurate muscle oxygen saturation (SmO2) measurement, one must select the appropriate source-detector distance (SD) to completely penetrate the fat layer. Methods: Six healthy subjects were supine for 15min to normalize tissue oxygenation across the body. NIR spectra were collected from the calf, shoulder, lower and upper thigh muscles with long SD distances of 30mm, 35mm, 40mm and 45mm. Spectral preprocessing with the short SD (3mm) spectrum preceded SmO2 calculation with a Taylor series expansion method. Three-way ANOVA was used to compare SmO2 values over varying fat thickness, subjects and SD distances. Results: Overlying fat layers varied in thickness from 4.9mm to 19.6mm across all subjects. SmO2 measured at the four locations were comparable for each subject (p=0.133), regardless of fat thickness and SD distance. SmO2 (mean+/-std dev) measured at calf, shoulder, low and high thigh were 62+/-3%, 59+/-8%, 61+/-2%, 61+/-4% respectively for SD distance of 30mm. In these subjects no significant influence of SD was observed (p=0.948). Conclusions: The results indicate that for our sensor design a 30mm SD is sufficient to penetrate through a 19mm fat layer and that orthogonalization with short SD effectively removed spectral interference from fat to result in a reproducible determination of SmO2.

  19. Accurate measurement of the rise and decay times of fast scintillators with solid state photon counters

    Science.gov (United States)

    Seifert, S.; Steenbergen, J. H. L.; van Dam, H. T.; Schaart, D. R.

    2012-09-01

    In this work we present a measurement setup for the determination of scintillation pulse shapes of fast scintillators. It is based on a time-correlated single photon counting approach that utilizes the correlation between 511 keV annihilation photons to produce start and stop signals in two separate crystals. The measurement is potentially cost-effective and simple to set up while maintaining an excellent system timing resolution of 125 ps. As a proof-of-concept the scintillation photon arrival time histograms were recorded for two well-known, fast scintillators: LYSO:Ce and LaBr3:5%Ce. The scintillation pulse shapes were modeled as a linear combination of exponentially distributed charge transfer and photon emission processes. Correcting for the system timing resolution, the exponential time constants were extracted from the recorded histograms. A decay time of 43 ns and a rise time of 72 ps were determined for LYSO:Ce thus demonstrating the capability of the system to accurately measure very fast rise times. In the case of LaBr3:5%Ce two processes were observed to contribute to the rising edge of the scintillation pulse. The faster component (270 ps) contributes with 72% to the rising edge of the scintillation pulse while the second, slower component (2.0 ns) contributes with 27%. The decay of the LaBr3:5%Ce scintillation pulse was measured to be 15.4 ns with a small contribution (2%) of a component with a larger time constant (130 ns).

  20. Accurate correction of magnetic field instabilities for high-resolution isochronous mass measurements in storage rings

    CERN Document Server

    Shuai, P; Zhang, Y H; Litvinov, Yu A; Wang, M; Tu, X L; Blaum, K; Zhou, X H; Yuan, Y J; Audi, G; Yan, X L; Chen, X C; Xu, X; Zhang, W; Sun, B H; Yamaguchi, T; Chen, R J; Fu, C Y; Ge, Z; Huang, W J; Liu, D W; Xing, Y M; Zeng, Q

    2014-01-01

    Isochronous mass spectrometry (IMS) in storage rings is a successful technique for accurate mass measurements of short-lived nuclides with relative precision of about $10^{-5}-10^{-7}$. Instabilities of the magnetic fields in storage rings are one of the major contributions limiting the achievable mass resolving power, which is directly related to the precision of the obtained mass values. A new data analysis method is proposed allowing one to minimise the effect of such instabilities. The masses of the previously measured at the CSRe $^{41}$Ti, $^{43}$V, $^{47}$Mn, $^{49}$Fe, $^{53}$Ni and $^{55}$Cu nuclides were re-determined with this method. An improvement of the mass precision by a factor of $\\sim 1.7$ has been achieved for $^{41}$Ti and $^{43}$V. The method can be applied to any isochronous mass experiment irrespective of the accelerator facility. Furthermore, the method can be used as an on-line tool for checking the isochronous conditions of the storage ring.

  1. Accurate measurement of interferometer group delay using field-compensated scanning white light interferometer.

    Science.gov (United States)

    Wan, Xiaoke; Wang, Ji; Ge, Jian

    2010-10-10

    Interferometers are key elements in radial velocity (RV) experiments in astronomy observations, and accurate calibration of the group delay of an interferometer is required for high precision measurements. A novel field-compensated white light scanning Michelson interferometer is introduced as an interferometer calibration tool. The optical path difference (OPD) scanning was achieved by translating a compensation prism, such that even if the light source were in low spatial coherence, the interference stays spatially phase coherent over a large interferometer scanning range. In the wavelength region of 500-560 nm, a multimode fiber-coupled LED was used as the light source, and high optical efficiency was essential in elevating the signal-to-noise ratio of the interferogram signal. The achromatic OPD scanning required a one-time calibration, and two methods using dual-laser wavelength references and an iodine absorption spectrum reference were employed and cross-verified. In an experiment measuring the group delay of a fixed Michelson interferometer, Fourier analysis was employed to process the interferogram data. The group delay was determined at an accuracy of 1×10(-5), and the phase angle precision was typically 2.5×10(-6) over the wide wavelength region.

  2. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2016-12-01

    Full Text Available Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1 an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2 a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time.

  3. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering

    Science.gov (United States)

    Moskalensky, Alexander E.; Yurkin, Maxim A.; Konokhova, Anastasiya I.; Strokotov, Dmitry I.; Nekrasov, Vyacheslav M.; Chernyshev, Andrei V.; Tsvetovskaya, Galina A.; Chikova, Elena D.; Maltsev, Valeri P.

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  4. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering.

    Science.gov (United States)

    Moskalensky, Alexander E; Yurkin, Maxim A; Konokhova, Anastasiya I; Strokotov, Dmitry I; Nekrasov, Vyacheslav M; Chernyshev, Andrei V; Tsvetovskaya, Galina A; Chikova, Elena D; Maltsev, Valeri P

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  5. Accurately measuring volume of soil samples using low cost Kinect 3D scanner

    Science.gov (United States)

    van der Sterre, Boy-Santhos; Hut, Rolf; van de Giesen, Nick

    2013-04-01

    The 3D scanner of the Kinect game controller can be used to increase the accuracy and efficiency of determining in situ soil moisture content. Soil moisture is one of the principal hydrological variables in both the water and energy interactions between soil and atmosphere. Current in situ measurements of soil moisture either rely on indirect measurements (of electromagnetic constants or heat capacity) or on physically taking a sample and weighing it in a lab. The bottleneck in accurately retrieving soil moisture using samples is the determining of the volume of the sample. Currently this is mostly done by the very time consuming "sand cone method" in which the volume were the sample used to sit is filled with sand. We show that 3D scanner that is part of the 150 game controller extension "Kinect" can be used to make 3D scans before and after taking the sample. The accuracy of this method is tested by scanning forms of known volume. This method is less time consuming and less error-prone than using a sand cone.

  6. Fast and accurate measurement of diffusion coefficient by Taylor's dispersion analysis

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This investigation aimed at improving the performance of Taylor's dispersion analysis for the fast and accurate measurement of diffusion coefficient of a minute solute in various solvents. The investigation was carried out on a capillary electrophoresis instrument by monitoring the UV absorption peak of a solute pulse and calculating the diffusion coefficient by peak efficiency. With L-phenylalanine as a main testing solute, some key factors were afterward disclosed including especially the capillary size, carrier flow velocity, injection volume and capillary conditioning. Peak tailing, large volume of sample injection and slow migration were found to underestimate the diffusion coefficient while very fast migration and high sample concentration caused overestimation. At a moderate flow velocity of 0.1―1 cm/s with a capillary of 72.44 μm I.D.×60 cm (50 cm effective) maintained at 25℃, the diffusion coefficient of aqueous L-phenylalanine was determined, giving a value of 7.02×10-6 cm2/s with error<2% and relative standard deviation<0.2% (n=3). The method was shown to be applicable to the measurement of various samples such as aqueous phenylalanine, acetone, phenol, toluene and benzene, and nonaqueous benzene (in ethanol or 1-butanol).

  7. An accurate mass and radius measurement for an ultracool white dwarf

    CERN Document Server

    Parsons, S G; Marsh, T R; Bergeron, P; Copperwheat, C M; Dhillon, V S; Bento, J; Littlefair, S P; Schreiber, M R

    2012-01-01

    Studies of cool white dwarfs in the solar neighbourhood have placed a limit on the age of the Galactic disk of 8-9 billion years. However, determining their cooling ages requires the knowledge of their effective temperatures, masses, radii, and atmospheric composition. So far, these parameters could only be inferred for a small number of ultracool white dwarfs for which an accurate distance is known, by fitting their spectral energy distributions (SEDs) in conjunction with a theoretical mass-radius relation. However, the mass-radius relation remains largely untested, and the derived cooling ages are hence model-dependent. Here we report direct measurements of the mass and radius of an ultracool white dwarf in the double-lined eclipsing binary SDSS J013851.54-001621.6. We find M(WD)=0.529+/-0.010Msol and R(WD)=0.0131+/-0.0003Rsol. Our measurements are consistent with the mass-radius relation and we determine a robust cooling age of 9.5 billion years for the 3570K white dwarf. We find that the mass and radius o...

  8. A particle-tracking approach for accurate material derivative measurements with tomographic PIV

    Science.gov (United States)

    Novara, Matteo; Scarano, Fulvio

    2013-08-01

    The evaluation of the instantaneous 3D pressure field from tomographic PIV data relies on the accurate estimate of the fluid velocity material derivative, i.e., the velocity time rate of change following a given fluid element. To date, techniques that reconstruct the fluid parcel trajectory from a time sequence of 3D velocity fields obtained with Tomo-PIV have already been introduced. However, an accurate evaluation of the fluid element acceleration requires trajectory reconstruction over a relatively long observation time, which reduces random errors. On the other hand, simple integration and finite difference techniques suffer from increasing truncation errors when complex trajectories need to be reconstructed over a long time interval. In principle, particle-tracking velocimetry techniques (3D-PTV) enable the accurate reconstruction of single particle trajectories over a long observation time. Nevertheless, PTV can be reliably performed only at limited particle image number density due to errors caused by overlapping particles. The particle image density can be substantially increased by use of tomographic PIV. In the present study, a technique to combine the higher information density of tomographic PIV and the accurate trajectory reconstruction of PTV is proposed (Tomo-3D-PTV). The particle-tracking algorithm is applied to the tracers detected in the 3D domain obtained by tomographic reconstruction. The 3D particle information is highly sparse and intersection of trajectories is virtually impossible. As a result, ambiguities in the particle path identification over subsequent recordings are easily avoided. Polynomial fitting functions are introduced that describe the particle position in time with sequences based on several recordings, leading to the reduction in truncation errors for complex trajectories. Moreover, the polynomial regression approach provides a reduction in the random errors due to the particle position measurement. Finally, the acceleration

  9. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  10. Accurate measurement of respiratory airway wall thickness in CT images using a signal restoration technique

    Science.gov (United States)

    Park, Sang Joon; Kim, Tae Jung; Kim, Kwang Gi; Lee, Sang Ho; Goo, Jin Mo; Kim, Jong Hyo

    2008-03-01

    Airway wall thickness (AWT) is an important bio-marker for evaluation of pulmonary diseases such as chronic bronchitis, bronchiectasis. While an image-based analysis of the airway tree can provide precise and valuable airway size information, quantitative measurement of AWT in Multidetector-Row Computed Tomography (MDCT) images involves various sources of error and uncertainty. So we have developed an accurate AWT measurement technique for small airways with three-dimensional (3-D) approach. To evaluate performance of these techniques, we used a set of acryl tube phantom was made to mimic small airways to have three different sizes of wall diameter (4.20, 1.79, 1.24 mm) and wall thickness (1.84, 1.22, 0.67 mm). The phantom was imaged with MDCT using standard reconstruction kernel (Sensation 16, Siemens, Erlangen). The pixel size was 0.488 mm × 0.488 mm × 0.75 mm in x, y, and z direction respectively. The images were magnified in 5 times using cubic B-spline interpolation, and line profiles were obtained for each tube. To recover faithful line profile from the blurred images, the line profiles were deconvolved with a point spread kernel of the MDCT which was estimated using the ideal tube profile and image line profile. The inner diameter, outer diameter, and wall thickness of each tube were obtained with full-width-half-maximum (FWHM) method for the line profiles before and after deconvolution processing. Results show that significant improvement was achieved over the conventional FWHM method in the measurement of AWT.

  11. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    Science.gov (United States)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  12. Enabling high grayscale resolution displays and accurate response time measurements on conventional computers.

    Science.gov (United States)

    Li, Xiangrui; Lu, Zhong-Lin

    2012-02-29

    Display systems based on conventional computer graphics cards are capable of generating images with 8-bit gray level resolution. However, most experiments in vision research require displays with more than 12 bits of luminance resolution. Several solutions are available. Bit++ (1) and DataPixx (2) use the Digital Visual Interface (DVI) output from graphics cards and high resolution (14 or 16-bit) digital-to-analog converters to drive analog display devices. The VideoSwitcher (3) described here combines analog video signals from the red and blue channels of graphics cards with different weights using a passive resister network (4) and an active circuit to deliver identical video signals to the three channels of color monitors. The method provides an inexpensive way to enable high-resolution monochromatic displays using conventional graphics cards and analog monitors. It can also provide trigger signals that can be used to mark stimulus onsets, making it easy to synchronize visual displays with physiological recordings or response time measurements. Although computer keyboards and mice are frequently used in measuring response times (RT), the accuracy of these measurements is quite low. The RTbox is a specialized hardware and software solution for accurate RT measurements. Connected to the host computer through a USB connection, the driver of the RTbox is compatible with all conventional operating systems. It uses a microprocessor and high-resolution clock to record the identities and timing of button events, which are buffered until the host computer retrieves them. The recorded button events are not affected by potential timing uncertainties or biases associated with data transmission and processing in the host computer. The asynchronous storage greatly simplifies the design of user programs. Several methods are available to synchronize the clocks of the RTbox and the host computer. The RTbox can also receive external triggers and be used to measure RT with respect

  13. An easy way to measure accurately the direct magnetoelectric voltage coefficient of thin film devices

    Science.gov (United States)

    Poullain, Gilles; More-Chevalier, Joris; Cibert, Christophe; Bouregba, Rachid

    2017-01-01

    TbxDy1-xFe2/Pt/Pb(Zrx, Ti1-x)O3 thin films were grown on Pt/TiO2/SiO2/Si substrate by multi-target sputtering. The magnetoelectric voltage coefficient αΗΜΕ was determined at room temperature using a lock-in amplifier. By adding, in series in the circuit, a capacitor of the same value as that of the device under test, we were able to demonstrate that the magnetoelectric device behaves as a voltage source. Furthermore, a simple way to subtract the stray voltage arising from the flow of eddy currents in the measurement set-up, is proposed. This allows the easy and accurate determination of the true magnetoelectric voltage coefficient. A large αΗΜΕ of 8.3 V/cm. Oe was thus obtained for a Terfenol-D/Pt/PZT thin film device, without DC magnetic field nor mechanical resonance.

  14. Assessing smoking status in disadvantaged populations: is computer administered self report an accurate and acceptable measure?

    Directory of Open Access Journals (Sweden)

    Bryant Jamie

    2011-11-01

    Full Text Available Abstract Background Self report of smoking status is potentially unreliable in certain situations and in high-risk populations. This study aimed to determine the accuracy and acceptability of computer administered self-report of smoking status among a low socioeconomic (SES population. Methods Clients attending a community service organisation for welfare support were invited to complete a cross-sectional touch screen computer health survey. Following survey completion, participants were invited to provide a breath sample to measure exposure to tobacco smoke in expired air. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Results Three hundred and eighty three participants completed the health survey, and 330 (86% provided a breath sample. Of participants included in the validation analysis, 59% reported being a daily or occasional smoker. Sensitivity was 94.4% and specificity 92.8%. The positive and negative predictive values were 94.9% and 92.0% respectively. The majority of participants reported that the touch screen survey was both enjoyable (79% and easy (88% to complete. Conclusions Computer administered self report is both acceptable and accurate as a method of assessing smoking status among low SES smokers in a community setting. Routine collection of health information using touch-screen computer has the potential to identify smokers and increase provision of support and referral in the community setting.

  15. Accurate Permittivity Measurements for Microwave Imaging via Ultra-Wideband Removal of Spurious Reflectors

    Directory of Open Access Journals (Sweden)

    Mathew G. Pelletier

    2010-09-01

    Full Text Available The use of microwave imaging is becoming more prevalent for detection of interior hidden defects in manufactured and packaged materials. In applications for detection of hidden moisture, microwave tomography can be used to image the material and then perform an inverse calculation to derive an estimate of the variability of the hidden material, such internal moisture, thereby alerting personnel to damaging levels of the hidden moisture before material degradation occurs. One impediment to this type of imaging occurs with nearby objects create strong reflections that create destructive and constructive interference, at the receiver, as the material is conveyed past the imaging antenna array. In an effort to remove the influence of the reflectors, such as metal bale ties, research was conducted to develop an algorithm for removal of the influence of the local proximity reflectors from the microwave images. This research effort produced a technique, based upon the use of ultra-wideband signals, for the removal of spurious reflections created by local proximity reflectors. This improvement enables accurate microwave measurements of moisture in such products as cotton bales, as well as other physical properties such as density or material composition. The proposed algorithm was shown to reduce errors by a 4:1 ratio and is an enabling technology for imaging applications in the presence of metal bale ties.

  16. Measurements of extremely low radioactivity levels in BOREXINO

    CERN Document Server

    Arpesella, C

    2001-01-01

    The techniques researched, developed and applied towards the measurement of radioisotope concentrations at ultra-low levels in the real-time solar neutrino experiment BOREXINO at Gran Sasso are presented and illustrated with specific results of widespread interest. We report the use of low-level germanium gamma spectrometry, low-level miniaturized gas proportional counters and low background scintillation detectors developed in solar neutrino research. Each now sets records in its field. We additionally describe our techniques of radiochemical ultra-pure, few atom manipulations and extractions. Forefront measurements also result from the powerful combination of neutron activation and low-level counting. Finally, with our techniques and commercially available mass spectrometry and atomic absorption spectroscopy, new low-level detection limits for isotopes of interest are obtained.

  17. Accurate measurement of transgene copy number in crop plants using droplet digital PCR.

    Science.gov (United States)

    Collier, Ray; Dasgupta, Kasturi; Xing, Yan-Ping; Hernandez, Bryan Tarape; Shao, Min; Rohozinski, Dominica; Kovak, Emma; Lin, Jeanie; de Oliveira, Maria Luiza P; Stover, Ed; McCue, Kent F; Harmon, Frank G; Blechl, Ann; Thomson, James G; Thilmony, Roger

    2017-06-01

    Genetic transformation is a powerful means for the improvement of crop plants, but requires labor- and resource-intensive methods. An efficient method for identifying single-copy transgene insertion events from a population of independent transgenic lines is desirable. Currently, transgene copy number is estimated by either Southern blot hybridization analyses or quantitative polymerase chain reaction (qPCR) experiments. Southern hybridization is a convincing and reliable method, but it also is expensive, time-consuming and often requires a large amount of genomic DNA and radioactively labeled probes. Alternatively, qPCR requires less DNA and is potentially simpler to perform, but its results can lack the accuracy and precision needed to confidently distinguish between one- and two-copy events in transgenic plants with large genomes. To address this need, we developed a droplet digital PCR-based method for transgene copy number measurement in an array of crops: rice, citrus, potato, maize, tomato and wheat. The method utilizes specific primers to amplify target transgenes, and endogenous reference genes in a single duplexed reaction containing thousands of droplets. Endpoint amplicon production in the droplets is detected and quantified using sequence-specific fluorescently labeled probes. The results demonstrate that this approach can generate confident copy number measurements in independent transgenic lines in these crop species. This method and the compendium of probes and primers will be a useful resource for the plant research community, enabling the simple and accurate determination of transgene copy number in these six important crop species. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  18. Three-Dimensional Venturi Sensor for Measuring Extreme Winds

    Science.gov (United States)

    Zysko, Jan A.; Perotti, Jose M.; Amis, Christopher; Randazzo, John; Blalock, Norman; Eckhoff, Anthony

    2003-01-01

    A three-dimensional (3D) Venturi sensor is being developed as a compact, rugged means of measuring wind vectors having magnitudes of as much as 300 mph (134 m/s). This sensor also incorporates auxiliary sensors for measuring temperature from -40 to +120 F (-40 to +49 C), relative humidity from 0 to 100 percent, and atmospheric pressure from 846 to 1,084 millibar (85 to 108 kPa). Conventional cup-and-vane anemometers are highly susceptible to damage by both high wind forces and debris, due to their moving parts and large profiles. In addition, they exhibit slow recovery times contributing to an inaccurately high average-speed reading. Ultrasonic and hot-wire anemometers overcome some of the disadvantages of the cup and-vane anemometers, but they have other disadvantageous features, including limited dynamic range and susceptibility to errors caused by external acoustic noise and rain. In contrast, the novel 3D Venturi sensor is less vulnerable to wind damage because of its smaller profile and ruggedness. Since the sensor has no moving parts, it provides increased reliability and lower maintenance costs. It has faster response and recovery times to changing wind conditions than traditional systems. In addition, it offers wide dynamic range and is expected to be relatively insensitive to rain and acoustic energy. The Venturi effect in this sensor is achieved by the mirrored double-inflection curve, which is then rotated 360 to create the desired detection surfaces. The curve is optimized to provide a good balance of pressure difference between sensor ports and overall maximum fluid velocity while in the shape. Four posts are used to separate the two shapes, and their size and location were chosen to minimize effects on the pressure measurements. The 3D Venturi sensor has smart software algorithms to map the wind pressure exerted on the surfaces of the design. Using Bernoulli's equation, the speed of the wind is calculated from the differences among the pressure

  19. A new direct absorption measurement for high precision and accurate measurement of water vapor in the UT/LS

    Science.gov (United States)

    Sargent, M. R.; Sayres, D. S.; Smith, J. B.; Anderson, J.

    2011-12-01

    Highly accurate and precise water vapor measurements in the upper troposphere and lower stratosphere are critical to understanding the climate feedbacks of water vapor and clouds in that region. However, the continued disagreement among water vapor measurements (~1 - 2 ppmv) are too large to constrain the role of different hydration and dehydration mechanisms operating in the UT/LS, with model validation dependent upon which dataset is chosen. In response to these issues, we present a new instrument for measurement of water vapor in the UT/LS that was flown during the April 2011 MACPEX mission out of Houston, TX. The dual axis instrument combines the heritage and validated accuracy of the Harvard Lyman-alpha instrument with a newly designed direct IR absorption instrument, the Harvard Herriott Hygrometer (HHH). The Lyman-alpha detection axis has flown aboard NASA's WB-57 and ER2 aircraft since 1994, and provides a requisite link between the new HHH instrument and the long history of Harvard water vapor measurements. The instrument utilizes the highly sensitive Lyman-alpha photo-fragment fluorescence detection method; its accuracy has been demonstrated though rigorous laboratory calibrations and in situ diagnostic procedures. The Harvard Herriott Hygrometer employs a fiber coupled near-IR laser with state-of-the-art electronics to measure water vapor via direct absorption in a spherical Herriott cell of 10 cm length. The instrument demonstrated in-flight precision of 0.1 ppmv (1-sec, 1-sigma) at mixing ratios as low as 5 ppmv with accuracies of 10% based on careful laboratory calibrations and in-flight performance. We present a description of the measurement technique along with our methodology for calibration and details of the measurement uncertainties. The simultaneous utilization of radically different measurement techniques in a single duct in the new Harvard Water Vapor (HWV) instrument allows for the constraint of systematic errors inherent in each technique

  20. Microscope—extreme stability requirements for femto-g measurements

    Science.gov (United States)

    Bousquet, P. W.; Pouilloux, B.; Serieys, C.; Bellouard, E.; Puillet, Ch.; Dubois, J.-B.

    2008-07-01

    Microscope is a 200 kg microsatellite which belongs to the CNES Myriad family. It is dedicated to a fundamental physics experiment. The satellite development is currently in Phase B. Launch is planned for 2011. The scientific objective of the mission is to test-for the first time in space-the equivalence principle (EP) with an accuracy 100 times better than that achieved in ground tests. The instruments developed by ONERA are composed of two differential electrostatic accelerometers operating at a finely stabilised temperature. Their resolution is as precise as 10-15 g. Continuous measurements will be made over periods of weeks. Furthermore, the satellite motion and attitude are precisely controlled by a drag free system which uses 12 micro-thrusters developed by ESA. After summarising the basic principles behind the scientific measurements, this paper will present the mechanical and thermal architecture of the satellite, which exhibits significant modifications with respect to the standard Myriad design. The major specifications will be presented, and we will show how the spacecraft configuration has been designed to satisfy the payload interface requirements, particularly for mechanical stability, thermal insulation and micro-cracking avoidance. The performance validation test plan will be presented, with results of elementary tests already performed. Finally, we will briefly describe an original de-orbiting system which Microscope will carry in order to comply with the space debris code of conduct. It consists of a deployable wing made of light-weight aluminised kapton membrane, deployed by an inflatable mast, which will enhance the atmospheric drag of the satellite after the end of its mission.

  1. An accurate air temperature measurement system based on an envelope pulsed ultrasonic time-of-flight technique.

    Science.gov (United States)

    Huang, Y S; Huang, Y P; Huang, K N; Young, M S

    2007-11-01

    A new microcomputer based air temperature measurement system is presented. An accurate temperature measurement is derived from the measurement of sound velocity by using an ultrasonic time-of-flight (TOF) technique. The study proposes a novel algorithm that combines both amplitude modulation (AM) and phase modulation (PM) to get the TOF measurement. The proposed system uses the AM and PM envelope square waveform (APESW) to reduce the error caused by inertia delay. The APESW ultrasonic driving waveform causes an envelope zero and phase inversion phenomenon in the relative waveform of the receiver. To accurately achieve a TOF measurement, the phase inversion phenomenon was used to sufficiently identify the measurement pulse in the received waveform. Additionally, a counter clock technique was combined to compute the phase shifts of the last incomplete cycle for TOF. The presented system can obtain 0.1% TOF resolution for the period corresponding to the 40 kHz frequency ultrasonic wave. Consequently, with the integration of a humidity compensation algorithm, a highly accurate and high resolution temperature measurement can be achieved using the accurate TOF measurement. Experimental results indicate that the combined standard uncertainty of the temperature measurement is approximately 0.39 degrees C. The main advantages of this system are high resolution measurements, narrow bandwidth requirements, and ease of implementation.

  2. Validity and interobserver agreement of lower extremity local tissue water measurements in healthy women using tissue dielectric constant

    DEFF Research Database (Denmark)

    Jensen, Mads R; Birkballe, Susanne; Nørregaard, Susan

    2012-01-01

    Tissue dielectric constant (TDC) measurement may become an important tool in the clinical evaluation of chronic lower extremity swelling in women; however, several factors are known to influence TDC measurements, and comparative data on healthy lower extremities are few....

  3. Infrared Thermometer: an accurate tool for temperature measurement during renal surgery

    Directory of Open Access Journals (Sweden)

    Giovanni Scala Marchini

    2013-07-01

    Full Text Available Purpose To evaluate infrared thermometer (IRT accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush and 10 without renal cooling (Group 2 - Warm Ischemia. Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT: immediate after clamping (T0, after 2 (T2, 5 (T5 and 10 minutes (T10. Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C. For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C. There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C. For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C. No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio

  4. Nanometre-accurate form measurement machine for E-ELT M1 segments

    NARCIS (Netherlands)

    Bos, A.; Henselmans, R.; Rosielle, P.C.J.N.; Steinbuch, M.

    2015-01-01

    To enable important scientific discoveries, ESO has defined a new ground-based telescope: the European Extremely Large Telescope (E-ELT). The baseline design features a telescope with a 39-m-class primary mirror (M1), making it the largest and most powerful telescope in the world. The M1 consists of

  5. Ages and Stages Questionnaire used to measure cognitive deficit in children born extremely preterm

    DEFF Research Database (Denmark)

    Klamer, Anja; Lando, Ane; Pinborg, Anja

    2005-01-01

    AIM: To validate the Ages and Stages Questionnaire (ASQ) and to measure average cognitive deficit in children born extremely preterm. METHODS: Parents of 30 term children aged 36-42 mo completed the ASQ and the children underwent the Wechsler Preschool and Primary Scales of Intelligence......--Revised. In a second study, the ASQ was obtained in 22 children born extremely preterm and 19 term children at the age of 35-44 mo. RESULTS: The overall ASQ score correlated significantly with IQ (p=0.007). The children born extremely preterm had an ASQ score of -1.06 SD below the score of the term children (p=0...

  6. Accurate wavelength prediction of photonic crystal resonant reflection and applications in refractive index measurement

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron L. C.

    2014-01-01

    In the past decade, photonic crystal resonant reflectors have been increasingly used as the basis for label-free biochemical assays in lab-on-a-chip applications. In both designing and interpreting experimental results, an accurate model describing the optical behavior of such structures is essen...

  7. In-situ measurements of material thermal parameters for accurate LED lamp thermal modelling

    NARCIS (Netherlands)

    Vellvehi, M.; Perpina, X.; Jorda, X.; Werkhoven, R.J.; Kunen, J.M.G.; Jakovenko, J.; Bancken, P.; Bolt, P.J.

    2013-01-01

    This work deals with the extraction of key thermal parameters for accurate thermal modelling of LED lamps: air exchange coefficient around the lamp, emissivity and thermal conductivity of all lamp parts. As a case study, an 8W retrofit lamp is presented. To assess simulation results, temperature is

  8. In-situ measurements of material thermal parameters for accurate LED lamp thermal modelling

    NARCIS (Netherlands)

    Vellvehi, M.; Perpina, X.; Jorda, X.; Werkhoven, R.J.; Kunen, J.M.G.; Jakovenko, J.; Bancken, P.; Bolt, P.J.

    2013-01-01

    This work deals with the extraction of key thermal parameters for accurate thermal modelling of LED lamps: air exchange coefficient around the lamp, emissivity and thermal conductivity of all lamp parts. As a case study, an 8W retrofit lamp is presented. To assess simulation results, temperature is

  9. In-Situ Acoustic Measurements of Temperature Profile in Extreme Environments

    Energy Technology Data Exchange (ETDEWEB)

    Skliar, Mikhail [Univ. of Utah, Salt Lake City, UT (United States)

    2015-03-31

    A gasifier’s temperature is the primary characteristic that must be monitored to ensure its performance and the longevity of its refractory. One of the key technological challenges impacting the reliability and economics of coal and biomass gasification is the lack of temperature sensors that are capable of providing accurate, reliable, and long-life performance in an extreme gasification environment. This research has proposed, demonstrated, and validated a novel approach that uses a noninvasive ultrasound method that provides real-time temperature distribution monitoring across the refractory, especially the hot face temperature of the refractory. The essential idea of the ultrasound measurements of segmental temperature distribution is to use an ultrasound propagation waveguide across a refractory that has been engineered to contain multiple internal partial reflectors at known locations. When an ultrasound excitation pulse is introduced on the cold side of the refractory, it will be partially reflected from each scatterer in the US propagation path in the refractory wall and returned to the receiver as a train of partial echoes. The temperature in the corresponding segment can be determined based on recorded ultrasonic waveform and experimentally defined relationship between the speed of sound and temperature. The ultrasound measurement method offers a powerful solution to provide continuous real time temperature monitoring for the occasions that conventional thermal, optical and other sensors are infeasible, such as the impossibility of insertion of temperature sensor, harsh environment, unavailable optical path, and more. Our developed ultrasound system consists of an ultrasound engineered waveguide, ultrasound transducer/receiver, and data acquisition, logging, interpretation, and online display system, which is simple to install on the existing units with minimal modification on the gasifier or use with new units. This system has been successfully tested

  10. Extreme Design Loads Calibration of Offshore Wind Turbine Blades through Real Time Measurements

    DEFF Research Database (Denmark)

    Natarajan, Anand; Vesth, Allan; Lamata, Rebeca Rivera

    Blade Root flap and Edge moments are measured on the blades of a 3.6MW offshore wind turbine in normal operation. Ten minute maxima of the measurements are sampled to determine the extreme blade root flap moment, edge moment and resultant moment over six month duration. A random subset of the mea...

  11. The use of geo radar in efficient and accurate snow measurements; Georadar for effektive og noeyaktige snoemaalinger

    Energy Technology Data Exchange (ETDEWEB)

    Sand, Knut [SINTEF, Trondheim (Norway); Faanes, Turid [Trondheim Energiverk, Trondheim (Norway)

    2001-07-01

    In the hydroelectric power industry, good measurements of snow masses at the end of the accumulation period are very important for establishing reliable prognoses for the inflow to the magazines. In a Norwegian pilot project, geo radar was used to measure snow masses and the results are interesting both with respect to accuracy and effectiveness. The water equivalent of the snow magazine is more accurately measured by means of geo radar than by more traditional means.

  12. The readout of the LHC beam luminosity monitor: accurate shower energy measurements at a 40 MHz repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Manfredi, P.F. E-mail: pfmanfredi@lbl.gov; Ratti, L.; Speziali, V.; Traversi, G.; Manghisoni, M.; Re, V.; Denes, P.; Placidi, M.; Ratti, A.; Turner, W.C.; Datte, P.S.; Millaud, J.E

    2004-02-01

    The LHC beam luminosity monitor is based on the following principle. The neutrals that originate in LHC at every PP interaction develop showers of minimum ionizing particles in the absorbers placed in front of the separation dipoles. The shower energy, measured by suitable detectors in the absorbers is proportional to the number of neutral particles and, therefore, to the luminosity. The principle lends itself to a luminosity measurement on a bunch-by-bunch basis. However, to make such a measurement feasible, the system must comply with extremely stringent requirements. Its speed of operation must match the 40 MHz bunch repetition rate of LHC. Besides, the detector must stand extremely high radiation doses. This paper discusses the solutions adopted to comply with these requirements.

  13. The readout of the LHC beam luminosity monitor Accurate shower energy measurements at a 40 MHz repetition rate

    CERN Document Server

    Manfredi, P F; Speziali, V; Traversi, G; Manghisoni, M; Re, V; Denes, P; Placidi, Massimo; Ratti, A; Turner, W C; Datte, P S; Millaud, J E

    2004-01-01

    The LHC beam luminosity monitor is based on the following principle. The neutrals that originate in LHC at every PP interaction develop showers of minimum ionizing particles in the absorbers placed in front of the separation dipoles. The shower energy, measured by suitable detectors in the absorbers is proportional to the number of neutral particles and, therefore, to the luminosity. The principle lends itself to a luminosity measurement on a bunch-by-bunch basis. However, to make such a measurement feasible, the system must comply with extremely stringent requirements. Its speed of operation must match the 40 MHz bunch repetition rate of LHC. Besides, the detector must stand extremely high radiation doses. This paper discusses the solutions adopted to comply with these requirements.

  14. A Novel Technology for Measurements of Dielectric Properties of Extremely Small Volumes of Liquids

    Directory of Open Access Journals (Sweden)

    Wei-Na Liu

    2016-01-01

    Full Text Available A high sensitivity sensor for measurement radio frequency (RF dielectric permittivity of liquids is described. Interference is used and parasitic effects are cancellation, which makes the sensor can catch weak signals caused by liquids with extremely small volumes. In addition, we present the relationship between transmission coefficient and permittivity of liquids under test (LUT. Using this sensor, quantitative measurements of the dielectric properties at 5.8 GHz are demonstrated of LUTs. Experiments show that the proposed method only requires the volume of 160 nanoliters for liquids. Therefore, the technology can be used for RF spectroscopic analysis of biological samples and extremely precious liquids.

  15. EVALUATION OF OPPORTUNITIES OF SOLAR ENERGETICS ON THE BASIS OF ACCURATE GROUND-BASED MEASUREMENTS OF SOLAR RADIATION

    Directory of Open Access Journals (Sweden)

    Aculinin A.

    2008-04-01

    Full Text Available Expected quantity of a solar energy received by solar panel is estimated on the basis of accurate measurements of solar radiation in Kishinev. Optimal orientation of solar panels and apparent volume of the electric power generated by solar panels are determined.

  16. A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

    NARCIS (Netherlands)

    van Leeuwen, Michiel; Heijnen, Joseph J.; Gardeniers, Johannes G.E.; Oudshoorn, Arthur; Noorman, Henk; Visser, Jan; van der Wielen, Luuk A.M.; van Gulik, Walter M.

    2009-01-01

    A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with

  17. A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

    NARCIS (Netherlands)

    Leeuwen, van Michiel; Heijnen, Joseph J.; Gardeniers, Han; Oudshoorn, Arthur; Noorman, Henk; Visser, Jan; Wielen, van der Luuk A.M.; Gulik, van Walter M.

    2009-01-01

    A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with k

  18. Accurate particle speed prediction by improved particle speed measurement and 3-dimensional particle size and shape characterization technique

    DEFF Research Database (Denmark)

    Cernuschi, Federico; Rothleitner, Christian; Clausen, Sønnik

    2017-01-01

    Accurate particle mass and velocity measurement is needed for interpreting test results in erosion tests of materials and coatings. The impact and damage of a surface is influenced by the kinetic energy of a particle, i.e. particle mass and velocity. Particle mass is usually determined with optic...

  19. Optical coherence tomography enables accurate measurement of equine cartilage thickness for determination of speed of sound.

    Science.gov (United States)

    Puhakka, Pia H; Te Moller, Nikae C R; Tanska, Petri; Saarakkala, Simo; Tiitu, Virpi; Korhonen, Rami K; Brommer, Harold; Virén, Tuomas; Jurvelin, Jukka S; Töyräs, Juha

    2016-08-01

    Background and purpose - Arthroscopic estimation of articular cartilage thickness is important for scoring of lesion severity, and measurement of cartilage speed of sound (SOS)-a sensitive index of changes in cartilage composition. We investigated the accuracy of optical coherence tomography (OCT) in measurements of cartilage thickness and determined SOS by combining OCT thickness and ultrasound (US) time-of-flight (TOF) measurements. Material and methods - Cartilage thickness measurements from OCT and microscopy images of 94 equine osteochondral samples were compared. Then, SOS in cartilage was determined using simultaneous OCT thickness and US TOF measurements. SOS was then compared with the compositional, structural, and mechanical properties of cartilage. Results - Measurements of non-calcified cartilage thickness using OCT and microscopy were significantly correlated (ρ = 0.92; p measurement of articular cartilage thickness. Although SOS measurements lacked accuracy in thin equine cartilage, the concept of SOS measurement using OCT appears promising.

  20. Local position measurement system for fast and accurate 3D monitoring

    Science.gov (United States)

    Fischer, Alexander; Pracherstorfer, Gerald; Stelzer, Andreas; Soeser, Andreas

    2003-07-01

    This contribution describes the components necessary for measurement of the three-dimensional local position of objects with high accuracy and high measurement rate. The methodology is based on the FMCW (frequency modulated continuous wave) technology in state of the art technology described as sensor system. A high speed real-time network collects data and transfers it to a master processing unit (MPU) where 3-D position data is calculated. It is described how to measure and how to process position data for a local, wide area measurement system. Results are shown for a series of static measurements and an outdoor Motocross race.

  1. Using item response theory to measure extreme response style in marketing research: a global investigation

    NARCIS (Netherlands)

    Jong, de Martijn G.; Steenkamp, Jan-Benedict E.M.; Fox, Jean-Paul; Baumgartner, Hans

    2008-01-01

    Extreme response style (ERS) is an important threat to the validity of survey-based marketing research. In this article, the authors present a new item response theory–based model for measuring ERS. This model contributes to the ERS literature in two ways. First, the method improves on existing proc

  2. Accurate NIRS measurement of muscle oxygenation by correcting the influence of a subcutaneous fat layer

    Science.gov (United States)

    Yamamoto, Katsuyuki; Niwayama, Masatsugu; Lin, Ling; Shiga, Toshikazu; Kudo, Nobuki; Takahashi, Makoto

    1998-01-01

    Although the inhomogeneity of tissue structure affects the sensitivity of tissue oxygenation measurement by reflectance near-infrared spectroscopy, few analyses of this effect have been reported. In this study, the influence of a subcutaneous fat layer on muscle oxygenation measurement was investigated by Monte Carlo simulation and experimental studies. In the experiments, measurement sensitivity was examined by measuring the falling rate of oxygenation in occlusion tests on the forearm using a tissue oxygen monitor. The fat layer thickness was measured by ultrasonography. Results of the simulation and occlusion tests clearly showed that the presence of a fat layer greatly decreases the measurement sensitivity and increases the light intensity at the detector. The correction factors of sensitivity were obtained from this relationship and were successfully validated by experiments on 12 subjects whose fat layer thickness ranged from 3.5 to 8 mm.

  3. Lightdrum-Portable Light Stage for Accurate BTF Measurement on Site.

    Science.gov (United States)

    Havran, Vlastimil; Hošek, Jan; Němcová, Šárka; Čáp, Jiří; Bittner, Jiří

    2017-02-23

    We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF) and the bidirectional texture function (BTF) of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED) modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0 ∘ to 75 ∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples.

  4. Lightdrum—Portable Light Stage for Accurate BTF Measurement on Site

    Directory of Open Access Journals (Sweden)

    Vlastimil Havran

    2017-02-01

    Full Text Available We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF and the bidirectional texture function (BTF of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0 ∘ to 75 ∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples.

  5. [Limb-length measurements using wooden boards: an accurate and experience-independent method

    NARCIS (Netherlands)

    Pakvis, D.F.M.; Jaarsma, R.L.; Kampen, A. van

    2003-01-01

    OBJECTIVE: To determine the precision and reliability of the indirect limb-length measurement, and the inter-observer variance between doctors differing in level of experience. DESIGN: Descriptive. METHOD: Indirect limb-length measurement by placing 0.5 cm-thick wooden boards under the foot of the s

  6. Archimedes Revisited: A Faster, Better, Cheaper Method of Accurately Measuring the Volume of Small Objects

    Science.gov (United States)

    Hughes, Stephen W.

    2005-01-01

    A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…

  7. Surface EMG measurements during fMRI at 3T : Accurate EMG recordings after artifact correction

    NARCIS (Netherlands)

    van Duinen, Hiske; Zijdewind, Inge; Hoogduin, H; Maurits, N

    2005-01-01

    In this experiment, we have measured surface EMG of the first dorsal interosseus during predefined submaximal isometric contractions (5, 15, 30, 50, and 70% of maximal force) of the index finger simultaneously with fMRI measurements. Since we have used sparse sampling fMRI (3-s scanning; 2-s non-sca

  8. Measuring laser power as a force: a new paradigm to accurately monitor optical power during laser-based machining operations

    Science.gov (United States)

    Williams, Paul; Simonds, Brian; Sowards, Jeffrey; Hadler, Joshua

    2016-03-01

    In laser manufacturing operations, accurate measurement of laser power is important for product quality, operational repeatability, and process validation. Accurate real-time measurement of high-power lasers, however, is difficult. Typical thermal power meters must absorb all the laser power in order to measure it. This constrains power meters to be large, slow and exclusive (that is, the laser cannot be used for its intended purpose during the measurement). To address these limitations, we have developed a different paradigm in laser power measurement where the power is not measured according to its thermal equivalent but rather by measuring the laser beam's momentum (radiation pressure). Very simply, light reflecting from a mirror imparts a small force perpendicular to the mirror which is proportional to the optical power. By mounting a high-reflectivity mirror on a high-sensitivity force transducer (scale), we are able to measure laser power in the range of tens of watts up to ~ 100 kW. The critical parameters for such a device are mirror reflectivity, angle of incidence, and scale sensitivity and accuracy. We will describe our experimental characterization of a radiation-pressure-based optical power meter. We have tested it for modulated and CW laser powers up to 92 kW in the laboratory and up to 20 kW in an experimental laser welding booth. We will describe present accuracy, temporal response, sources of measurement uncertainty, and hurdles which must be overcome to have an accurate power meter capable of routine operation as a turning mirror within a laser delivery head.

  9. Accurate measurement of guided modes in a plate using a bidirectional approach.

    Science.gov (United States)

    Moreau, Ludovic; Minonzio, Jean-Gabriel; Foiret, Josquin; Bossy, Emmanuel; Talmant, Maryline; Laugier, Pascal

    2014-01-01

    Measuring guided wave propagation in long bones is of interest to the medical community. When an inclination exists between the probe and the tested specimen surface, a bias is introduced on the guided mode wavenumbers. The aim of this study was to generalize the bidirectional axial transmission technique initially developed for the first arriving signal. Validation tests were performed on academic materials such a bone-mimicking plate covered with either a silicon or fat-mimicking layer. For any inclination, the wavenumbers measured with the probe parallel to the waveguide surface can be obtained by averaging the wavenumbers measured in two opposite directions.

  10. Fast and accurate measurement of on-axis gain and on-axis polarization at a finite distance

    DEFF Research Database (Denmark)

    Pivnenko, S.; Breinbjerg, O.

    2013-01-01

    In this paper, a technique for fast and accurate measurement of on-axis gain and on-axis polarization characteristics of antennas, such as Standard Gain Horns, compact range feed horns, and near-field probes, is described. The proposed gain determination procedure is a modification of the far-field...... orientations versus a polarization calibrated probe. A complete set of measurements for one AUT takes less than two hours. The measurement uncertainty for the gain is comparable to the one obtained with the near-field substitution technique and typically does not exceed 0.1 dB (1 sigma)....

  11. Accurate on-chip measurement of the Seebeck coefficient of high mobility small molecule organic semiconductors

    Directory of Open Access Journals (Sweden)

    C. N. Warwick

    2015-09-01

    Full Text Available We present measurements of the Seebeck coefficient in two high mobility organic small molecules, 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT and 2,9-didecyl-dinaphtho[2,3-b:2′,3′-f]thieno[3,2-b]thiophene (C10-DNTT. The measurements are performed in a field effect transistor structure with high field effect mobilities of approximately 3 cm2/V s. This allows us to observe both the charge concentration and temperature dependence of the Seebeck coefficient. We find a strong logarithmic dependence upon charge concentration and a temperature dependence within the measurement uncertainty. Despite performing the measurements on highly polycrystalline evaporated films, we see an agreement in the Seebeck coefficient with modelled values from Shi et al. [Chem. Mater. 26, 2669 (2014] at high charge concentrations. We attribute deviations from the model at lower charge concentrations to charge trapping.

  12. A universal and flexible theodolite-camera system for making accurate measurements over large volumes

    Science.gov (United States)

    Zhang, Xiaohu; Zhu, Zhaokun; Yuan, Yun; Li, Lichun; Sun, Xiangyi; Yu, Qifeng; Ou, Jianliang

    2012-11-01

    Typically, optical measurement systems can achieve high accuracy over a limited volume, or cover a large volume with low accuracy. In this paper, we propose a universal way of integrating a camera with a theodolite to construct a theodolite-camera (TC) measurement system that can make measurements over a large volume with high accuracy. The TC inherits the advantages of high flexibility and precision from theodolite and camera, but it avoids the need to perform elaborate adjustments on the camera and theodolite. The TC provides a universal and flexible approach to the camera-on-theodolite system. We describe three types of TC based separately on: (i) a total station; (ii) a theodolite; and (iii) a general rotation frame. We also propose three corresponding calibration methods for the different TCs. Experiments have been conducted to verify the measuring accuracy of each of the three types of TC.

  13. Novel methodology for accurate resolution of fluid signatures from multi-dimensional NMR well-logging measurements

    Science.gov (United States)

    Anand, Vivek

    2017-03-01

    A novel methodology for accurate fluid characterization from multi-dimensional nuclear magnetic resonance (NMR) well-logging measurements is introduced. This methodology overcomes a fundamental challenge of poor resolution of features in multi-dimensional NMR distributions due to low signal-to-noise ratio (SNR) of well-logging measurements. Based on an unsupervised machine-learning concept of blind source separation, the methodology resolves fluid responses from simultaneous analysis of large quantities of well-logging data. The multi-dimensional NMR distributions from a well log are arranged in a database matrix that is expressed as the product of two non-negative matrices. The first matrix contains the unique fluid signatures, and the second matrix contains the relative contributions of the signatures for each measurement sample. No a priori information or subjective assumptions about the underlying features in the data are required. Furthermore, the dimensionality of the data is reduced by several orders of magnitude, which greatly simplifies the visualization and interpretation of the fluid signatures. Compared to traditional methods of NMR fluid characterization which only use the information content of a single measurement, the new methodology uses the orders-of-magnitude higher information content of the entire well log. Simulations show that the methodology can resolve accurate fluid responses in challenging SNR conditions. The application of the methodology to well-logging data from a heavy oil reservoir shows that individual fluid signatures of heavy oil, water associated with clays and water in interstitial pores can be accurately obtained.

  14. Accurate measurement of the main refractive indices and thermo-optical coefficients of the calcite crystal

    Institute of Scientific and Technical Information of China (English)

    Shuang Zhao; Fuquan Wu; Haifeng Wang; Weigang Zhong; Xiuzhen Li; Hengjing Tang; Meng Shi; Hongyan Deng

    2007-01-01

    The main refractive indices of calcite crystal are measured by the means of auto-collimation, and the thermo-optical coefficients are calculated. The coefficient expression of Sellmeier equation is obtained by solving Sellmeier equation strictly and the refractive indices of different wavelengths are calculated, which accord with experimental esultsery well. The measured main refractive indices of calcite at 488-nm wavelength are identical with the values obtained by Sellmeier equation.

  15. Accurate measurement of poleward microtubule flux in the spindle of Drosophila S2 cells.

    Science.gov (United States)

    Munzarova, Alina; Popova, Julia; Razuvaeva, Alena; Shloma, Victor; Gatti, Maurizio; Omelyanchuk, Leonid

    2016-09-01

    The spindle microtubule (MT) flux is the continuous translocation of MTs toward the spindle poles caused by MT polymerization at plus ends coupled to depolymerization at minus ends. Poleward flux is observed in both mitotic and meiotic spindles; it is evolutionarily conserved and contributes to the regulation of spindle length and anaphase chromosome movement. MT photobleaching is a tool frequently used to measure poleward flux. Spindles containing fluorescently tagged tubulin are photobleached to generate a non-fluorescent stripe, which moves toward the spindle poles allowing a measure of the flux. However, this method only permits rapid measurements of the flux, because the fluorescence of the bleached stripe recovers rapidly due to the spindle MT turnover. Here, we describe a modification of the current photobleaching-based method for flux measurement. We photobleached two large areas at the opposite sides of the metaphase plate in spindles of Drosophila S2 cells expressing Cherry-tagged tubulin, leaving unbleached only the area near the chromosomes. We then measured the speed with which the fluorescent MTs move toward the poles. We found that this method allows a measure of the flux over a two- to threefold longer time than the "single stripe" method, providing a reliable evaluation of the flux rate. © 2016 International Federation for Cell Biology.

  16. External urethral sphincter pressure measurement: an accurate method for the diagnosis of detrusor external sphincter dyssynergia?

    Directory of Open Access Journals (Sweden)

    Carlos H Suzuki Bellucci

    Full Text Available BACKGROUND: Combined pelvic floor electromyography (EMG and videocystourethrography (VCUG during urodynamic investigation are the most acceptable and widely agreed methods for diagnosing detrusor external sphincter dyssynergia (DESD. Theoretically, external urethral sphincter pressure (EUSP measurement would provide enough information for the diagnosis of DESD and could simplify the urodynamic investigation replacing combined pelvic floor EMG and VCUG. Thus, we evaluated the diagnostic accuracy of EUSP measurement for DESD. PATIENTS #ENTITYSTARTX00026; METHODS: A consecutive series of 72 patients (36 women, 36 men with neurogenic lower urinary tract dysfunction able to void spontaneously was prospectively evaluated at a single university spinal cord injury center. Diagnosis of DESD using EUSP measurement (index test versus combined pelvic floor EMG and VCUG (reference standard was assessed according to the recommendations of the Standards for Reporting of Diagnostic Accuracy Initiative. RESULTS: Using EUSP measurement (index test and combined pelvic floor EMG and VCUR (reference standard, DESD was diagnosed in 10 (14% and in 41 (57% patients, respectively. More than half of the patients presented discordant diagnosis between the index test and the reference standard. Among 41 patients with DESD diagnosed by combined pelvic floor EMG and VCUR, EUSP measurement identified only 6 patients. EUSP measurement had a sensitivity of 15% (95% CI 5%-25%, specificity of 87% (95% CI 76%-98%, positive predictive value of 60% (95% CI 30%-90%, and negative predictive value of 56% (95% CI 44%-68% for the diagnosis of DESD. CONCLUSIONS: For diagnosis of DESD, EUSP measurement is inaccurate and cannot replace combined pelvic floor EMG and VCUR.

  17. Measurement of colonic polyps by radiologists and endoscopists: Who is most accurate?

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, S.; Halligan, S.; Greenhalgh, R.; Godbold, J.; Taylor, S.A. [University College Hospital, Department of Specialist Radiology, Podium Level 2, London (United Kingdom); Irving, P.; Bloom, S.; Bungay, A. [University College Hospital, Department of Gastroenterology, London (United Kingdom); Altman, D.G. [Wolfson College Annexe, Centre for Statistics in Medicine, Oxford (United Kingdom)

    2008-05-15

    The purpose was to determine the accuracy of polyp measurement by endoscopy and CT. A colonic phantom was constructed containing 12 simulated polyps of known diameter. Polyp diameter was estimated during endoscopy by two observers independently. The phantom was then scanned using a 64-detector-row machine and diameter estimated by a further two observers independently, using 2D and 3D visualisation methods. All measurements were obtained twice. Bland-Altman statistics were used to assess agreement between observers' estimates and the reference diameter. The mean difference between observers' measurements and the reference diameter was smallest for estimates made using 3D CT (-0.09 mm and -0.03 mm) and greatest for endoscopy (-1.10 mm and -1.19 mm), with 2D CT intermediate. However, 95% limits of agreement were largest for 3D CT estimates (-4.38 mm to 4.20 mm). Estimates by 2D CT consistently overestimated polyp diameter, whereas endoscopy consistently underestimated diameter. In contrast, measurements by 3D CT were a combination of over- and under-estimates, with a tendency for disagreement to increase with the size of the polyp. The effect of observer experience was small and repeatability was best for 2D CT. Measurement error was encountered with all three modalities tested. Estimates made by 2D CT were believed to offer the best compromise overall. (orig.)

  18. Inflation model building with an accurate measure of e-folding

    CERN Document Server

    Chongchitnan, Sirichai

    2016-01-01

    We revisit the problem of measuring the number of e-folding during inflation. It has become standard practice to take the logarithmic growth of the scale factor as a measure of the amount of inflation. However, this is only an approximation for the true amount of inflation required to solve the horizon and flatness problems. The aim of this work is to quantify the error in this approximation, and show how it can be avoided. We present an alternative framework for inflation model building using the inverse Hubble radius, aH, as the key parameter. We show that in this formalism, the correct number of e-folding arises naturally as a measure of inflation. As an application, we present an interesting model in which the entire inflationary dynamics can be solved analytically and exactly, and, in special cases, reduces to the familiar class of power-law models.

  19. Accurate DOSY measure of out-of-equilibrium systems by permutated DOSY (p-DOSY)

    CERN Document Server

    Oikonomou, Maria; Velders, Aldrik H; Delsuc, Marc-André

    2015-01-01

    NMR spectroscopy is a perfect tool for monitoring in-situ chemical reactions. In particular, DOSY measurement is well suited to characterize transient species by the determination of their sizes. However, here we bring to light a difficulty in the DOSY experiments performed on out-of-equilibrium systems. On such a system, the evolution of the concentration of species interferes with the measurement process, and creates a bias on the diffusion coefficient determination that may lead to erroneous interpretations. We show that a random permutation of the series of gradient strengths used during the DOSY experiment allows to average out this bias. This approach, that we name p-DOSY does not require changes in the the pulse sequences nor in the processing software, and restores completely the full accuracy of the measure. This technique is demonstrated on the monitoring of the anomerization reaction of $\\alpha$ to $\\beta$ glucose.

  20. Accurate measurement of neodymium isotopic composition using Neptune MC-ICP-MS

    Institute of Scientific and Technical Information of China (English)

    Yueheng YANG; Hongfu ZHANG; Liewen XIE; Fuyuan WU

    2008-01-01

    This paper reports the measurement of the Neodymium isotopic composition by Neptune Multiple Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) over the last two years. Although there is concomitant Cerium in the chemical separation process, this has no significant influence on the Neodymium analysis. As for the sample containing small amounts of Samarium (Sm/Nd<0.04), direct calibration for isobaric interference and mass discrimina-tion by the exponential law can be obtained by assuming that Samarium mass discrimination is the same as that of Neodymium. Geological samples after traditional chemi-cal separation were measured by Neptune MC-ICP-MS and Thermal Ionization Mass Spectrometry (TIMS) respectively. The results show that Neptune MC-ICP-MS can measure Neodymium isotopic composition as precisely the TIMS does and is even more effective and less time-consuming than the TIMS Method.

  1. ACCUWIND - Accurate wind speed measurements in wind energy - Summary report[Cup and sonic anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.; Dahlberg, J.Aa.; Cuerva, A.; Mouzakis, F.; Busche, P.; Eecen, P.; Sanz-Andres, A.; Franchini, S.; Markkilde Petersen, S.

    2006-07-15

    The cup anemometer is at present the standard instrument used for mean wind speed measurement in wind energy. It is being applied in high numbers around the world for wind energy assessments. It is also applied exclusively for accredited power performance measurements for certification and verification purposes, and for purposes of optimisation in research and development. The revised IEC standard on power performance measurements has now included requirements for classification of cup anemometers. The basis for setting up such requirements of cup anemometers is two EU projects SITEPARIDEN and CLASSCUP from which the proposed classification method for cup anemometers was developed for the IEC standard. While cup anemometers at present are the standard anemometer being used for average wind speed measurements, sonic anemometers have been developed significantly over the last years, and prices have come down. The application of sonic anemometers may increase in wind energy if they prove to have comparable or better operational characteristics compared to cup anemometers, and if similar requirements to sonic anemometers are established as for cup anemometers. Sonic anemometers have historically been used by meteorologists for turbulence measurements, but have also found a role on wind turbine nacelles for wind speed and yaw control purposes. The report on cup and sonic anemometry deals with establishment of robustness in assessment and classification by focus on methods and procedures for analysis of characteristics of cup and sonic anemometers. The methods and procedures provide a platform, hopefully for use in meeting the requirements of the IEC standard on power performance measurements, as well as for development of improved instruments. (au)

  2. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    Science.gov (United States)

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  3. Accurate measurement of the transition dipole moment of self-assembled quantum dots

    DEFF Research Database (Denmark)

    Stobbe, Søren; Johansen, Jeppe; Nikolaev, I.S.

    2007-01-01

    Here we present quantitative measurements of the dipole moment of an ensemble of self-assembled quantum dots employing a modified optical local density of states (LDOS). The LDOS is controlled by varying the distance from the QDs to a semiconductor/air interface.......Here we present quantitative measurements of the dipole moment of an ensemble of self-assembled quantum dots employing a modified optical local density of states (LDOS). The LDOS is controlled by varying the distance from the QDs to a semiconductor/air interface....

  4. Program package for accurate 3D field reconstruction from boundary measurements

    CERN Document Server

    Artyukh, A G; Belyakova, T V

    2002-01-01

    The problem of the magnetic field reconstruction inside a subregion in R sup 3 from magnetic measurements on the closed boundary of this subregion is considered. The efficiency of the proposed method, algorithm and associated software for the precision magnet system is discussed. The results of the software verification, numerical experiments as well as the ones of the field reconstruction using boundary measurements in the magnet M1 of the separator COMBAS are given. Requirements to the position accuracy of sensors consistent with the required accuracy of the magnetic field reconstruction are defined. Recommendations on the magnetic scheme design for the field mapping are given.

  5. Accurate phasor measurement for transmission line protection in the presence of shunt capacitor banks

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Soon-Ryul; Kang, Sang-Hee [Department of Electrical Engineering and Next-Generation Power Technology Center, Myongji University (Korea); Park, Jong-Keun [School of Electrical Engineering, Seoul National University (Korea)

    2007-10-15

    This paper proposes a phasor measurement algorithm for transmission systems compensated with shunt capacitor banks. Since the shunt capacitor banks tend to lower the resonant frequencies, the dominant component, which has the lowest resonant frequency, is insufficiently attenuated by a low-pass filter and has an adverse influence on the phasor measurement of the fundamental component in a fault current signal. This paper theoretically investigates the dominant frequency in the presence of shunt capacitor banks and presents a phasor measurement algorithm immune to the dominant component and DC-offset. The performance of the algorithm is evaluated for a-phase to ground (a-g) faults on a 154-kV transmission system compensated with shunt capacitor banks. The evaluation results indicate that the algorithm can measure the phasor reliably and satisfactorily, although the fault current signal is distorted with the dominant component and DC-offset. The paper concludes by describing the hardware implementation of the algorithm on a prototype unit based on a digital signal processor. (author)

  6. Accurate measurement of the kinetic coefficient of friction between a surface and a granular mass

    NARCIS (Netherlands)

    Rademacher, F.J.C.

    1978-01-01

    A device has been developed for correct measurement of the kinematic coefficient of friction between a cohesionless granular material and a surface. Particle size may range from 0.5 up to about 9 mm, depending somewhat on the desired accuracy. Sliding velocity of the granules with respect to the sur

  7. New insights for accurate chemically specific measurements of slow diffusing molecules

    Science.gov (United States)

    Hou, Jianbo; Madsen, Louis A.

    2013-02-01

    Investigating the myriad features of molecular transport in materials yields fundamental information for understanding processes such as ion conduction, chemical reactions, and phase transitions. Molecular transport especially impacts the performance of ion-containing liquids and polymeric materials when used as electrolytes and separation media, with applications encompassing battery electrolytes, reverse-osmosis membranes, mechanical transducers, and fuel cells. Nuclear magnetic resonance (NMR) provides a unique probe of molecular translations by allowing measurement of all mobile species via spectral selectivity, access to a broad range of transport coefficients, probing of any material direction, and investigation of variable lengthscales in a material, thus, tying morphology to transport. Here, we present new concepts to test for and guarantee robust diffusion measurements. We first employ a standard pulsed-field-gradient (PFG) calibration protocol using 2H2O and obtain expected results, but we observe crippling artifacts when measuring 1H-glycerol diffusion with the same experimental parameters. A mathematical analysis of 2H2O and glycerol signals in the presence of PFG transients show tight agreement with experimental observations. These analyses lead to our principal findings that (1) negligible artifacts observed with low gyromagnetic ratio (γ) nuclei may become dominant when observing high γ nuclei, and (2) reducing the sample dimension along the gradient direction predictably reduces non-ideal behaviors of NMR signals. We further provide a useful quantitative strategy for error minimization when measuring diffusing species slower than the one used for gradient calibration.

  8. Integrating sphere-based setup as an accurate system for optical properties measurements

    CSIR Research Space (South Africa)

    Abdalmonem, S

    2010-09-01

    Full Text Available Determination of the optical properties of solid and liquid samples has great importance. Since the integrating sphere-based setup is used to measure the amount of reflected and transmitted light by the examined samples, optical properties could...

  9. Development and calibration of an accurate 6-degree-of-freedom measurement system with total station

    Science.gov (United States)

    Gao, Yang; Lin, Jiarui; Yang, Linghui; Zhu, Jigui

    2016-12-01

    To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial inclinometer, is designed to be portable in use. Subsequently, a precise mathematical model is proposed from the input variables observed by total station, imaging system and inclinometer to the output six pose variables. The model must be calibrated in two levels: the intrinsic parameters of imaging system, and the rotation matrix between coordinate systems of the camera and the inclinometer. Then corresponding approaches are presented. For the first level, we introduce a precise two-axis rotary table as a calibration reference. And for the second level, we propose a calibration method by varying the pose of a rigid body with the target sensor and a reference prism on it. Finally, through simulations and various experiments, the feasibilities of the measurement model and calibration methods are validated, and the measurement accuracy of the system is evaluated.

  10. Treatment response classification of liver metastatic disease evaluated on imaging. Are RECIST unidimensional measurements accurate?

    Science.gov (United States)

    Mantatzis, Michael; Kakolyris, Stylianos; Amarantidis, Kyriakos; Karayiannakis, Anastasios; Prassopoulos, Panos

    2009-07-01

    The purpose of this study was to evaluate the accuracy of unidimensional measurements (response evaluation criteria in solid tumors, RECIST) compared with volumetric measurements in patients with liver metastases undergoing chemotherapy. Forty-four patients with newly diagnosed liver lesions underwent three MRI examinations at treatment initiation, during chemotherapy, and immediately post-treatment. Measurements based on RECIST guidelines and volume calculations were performed on the "target" lesions (TLs). The two methods were in agreement in 64/77 of patients and 253/301 of individual lesions classification in response categories ("good" agreement, Cohen kappa = 0.735 and 0.741, respectively). In 16.88% of the comparisons the two methods stratified patients to a different response category; 27.6% of TLs did not follow the response category of the patient in whom lesions were located. The actual volume of TLs differs from the calculated volume of a sphere with the same diameter. Our study supports the use of volumetric techniques that may overcome certain disadvantages of unidimensional measurements.

  11. Implications of progesterone metabolism in MA-10 cells for accurate measurement of the rate of steroidogenesis.

    NARCIS (Netherlands)

    Rommerts, F.F.; King, S.R.; Span, P.N.

    2001-01-01

    In virtually all studies with MA-10 cells, progesterone RIAs have been used to measure steroid synthesis. To test whether progesterone is a stable end product, we investigated the metabolism of added tritiated progesterone and pregnenolone in MA-10 cells over a period of 3 h. Steroids were then extr

  12. Real-time and accurate rail wear measurement method and experimental analysis.

    Science.gov (United States)

    Liu, Zhen; Li, Fengjiao; Huang, Bangkui; Zhang, Guangjun

    2014-08-01

    When a train is running on uneven or curved rails, it generates violent vibrations on the rails. As a result, the light plane of the single-line structured light vision sensor is not vertical, causing errors in rail wear measurements (referred to as vibration errors in this paper). To avoid vibration errors, a novel rail wear measurement method is introduced in this paper, which involves three main steps. First, a multi-line structured light vision sensor (which has at least two linear laser projectors) projects a stripe-shaped light onto the inside of the rail. Second, the central points of the light stripes in the image are extracted quickly, and the three-dimensional profile of the rail is obtained based on the mathematical model of the structured light vision sensor. Then, the obtained rail profile is transformed from the measurement coordinate frame (MCF) to the standard rail coordinate frame (RCF) by taking the three-dimensional profile of the measured rail waist as the datum. Finally, rail wear constraint points are adopted to simplify the location of the rail wear points, and the profile composed of the rail wear points are compared with the standard rail profile in RCF to determine the rail wear. Both real data experiments and simulation experiments show that the vibration errors can be eliminated when the proposed method is used.

  13. Fast and Accurate Collocation of the Visible Infrared Imaging Radiometer Suite Measurements with Cross-Track Infrared Sounder

    Directory of Open Access Journals (Sweden)

    Likun Wang

    2016-01-01

    Full Text Available Given the fact that Cross-track Infrared Sounder (CrIS and the Visible Infrared Imaging Radiometer Suite (VIIRS are currently onboard the Suomi National Polar-orbiting Partnership (Suomi NPP satellite and will continue to be carried on the same platform as future Joint Polar Satellite System (JPSS satellites for the next decade, it is desirable to develop a fast and accurate collocation scheme to collocate VIIRS products and measurements with CrIS for applications that rely on combining measurements from two sensors such as inter-calibration, geolocation assessment, and cloud detection. In this study, an accurate and fast collocation method to collocate VIIRS measurements within CrIS instantaneous field of view (IFOV directly based on line-of-sight (LOS pointing vectors is developed and discussed in detail. We demonstrate that this method is not only accurate and precise from a mathematical perspective, but also easy to implement computationally. More importantly, with optimization, this method is very fast and efficient and thus can meet operational requirements. Finally, this collocation method can be extended to a wide variety of sensors on different satellite platforms.

  14. Measurement of testicular volume in smaller testes: how accurate is the conventional orchidometer?

    Science.gov (United States)

    Lin, Chih-Chieh; Huang, William J S; Chen, Kuang-Kuo

    2009-01-01

    The aim of this study was to evaluate the accuracy of different methods, including the Seager orchidometer (SO) and ultrasonography (US), for assessing testicular volume of smaller testes (testes volume less than 18 mL). Moreover, the equations used for the calculations--the Hansen formula (length [L] x width [W](2) x 0.52, equation A), the prolate ellipsoid formula (L x W x height [H] x 0.52, equation B), and the Lambert equation (L x W x H x 0.71, equation C)--were also examined and compared with the gold standard testicular volume obtained by water displacement (Archimedes principle). In this study, 30 testes from 15 men, mean age 75.3 (+/-8.3) years, were included. They all had advanced prostate cancer and were admitted for orchiectomy. Before the procedure, all the testes were assessed using SO and US. The dimensions were then input into each equation to obtain the volume estimates. The testicular volume by water displacement was 8.1 +/- 3.5 mL. Correlation coefficients (R(2)) of the 2 different methods (SO, US) to the gold standard were 0.70 and 0.85, respectively. The calculated testicular volumes were 9.2 +/- 3.9 mL (measured by SO, equation A), 11.9 +/- 5.2 mL (measured by SO, equation C), 7.3 +/- 4.2 mL (measured by US, equation A), 6.5 +/- 3.3 mL (measured by US, equation B) and 8.9 +/- 4.5 mL (measured by US, equation C). Only the mean size measured by US and volume calculated with the Hansen equation (equation A) and the mean size measured by US and volume calculated with the Lambert equation (equation C) showed no significant differences when compared with the volumes estimated by water displacement (mean difference 0.81 mL, P = .053, and 0.81 mL, P = .056, respectively). Based on our measurements, we categorized testicular volume by different cutoff values (7.0 mL, 7.5 mL, 8.0 mL, and 8.5 mL) to calculate a new constant for use in the Hansen equation. The new constant was 0.59. We then reexamined the equations using the new 0.59 constant, and found

  15. An X-band waveguide measurement technique for the accurate characterization of materials with low dielectric loss permittivity

    Science.gov (United States)

    Allen, Kenneth W.; Scott, Mark M.; Reid, David R.; Bean, Jeffrey A.; Ellis, Jeremy D.; Morris, Andrew P.; Marsh, Jeramy M.

    2016-05-01

    In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S21) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S21 measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis of our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10-3 for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. The method was validated by excellent agreement with a free-space focused-beam system measurement of a polypropylene sheet. This technique provides the material measurement community with the ability to accurately extract material properties of low-loss material specimen over the entire X-band range. This technique could easily be extended to other frequency bands.

  16. Development of a scattering probability method for accurate vapor fraction measurements by neutron radiography

    CERN Document Server

    Joo, H

    1999-01-01

    Recent test results indicated drawbacks associated with the simple exponential attenuation method (SEAM) as currently applied to neutron radiography measurements to determine vapor fractions in a hydrogenous two-phase flow in a metallic conduit. The scattering component of the neutron beam intensity exiting the flow system is not adequately accounted for by SEAM, and this leads to inaccurate results. To properly account for the scattering effect, a neutron scattering probability method (SPM) is developed. The method applies a neutron-hydrogen scattering kernel to scattered thermal neutrons that leave the incident beam in narrow conduits but eventually show up elsewhere in the measurements. The SPM has been tested with known vapor (void) distributions within an acrylic disk and a water/vapor channel. The vapor (void) fractions deduced by SPM are in good agreement with the known exact values. Details of the scattering correction method and the test results are discussed.

  17. Simultaneous and accurate measurement of the dielectric constant at many frequencies spanning a wide range

    CERN Document Server

    Pérez-Aparicio, Roberto; Cottinet, Denis; Tanase, Marius; Metz, Pascal; Bellon, Ludovic; Naert, Antoine; Ciliberto, Sergio

    2015-01-01

    We present an innovative technique which allows the simultaneous measurement of the dielectric constant of a material at many frequencies, spanning a four orders of magnitude range chosen between 10 --2 Hz and 10 4 Hz. The sensitivity and accuracy are comparable to those obtained using standard single frequency techniques. The technique is based on three new and simple features: a) the precise real time correction of the amplication of a current amplier; b) the specic shape of the excitation signal and its frequency spectrum; and c) the precise synchronization between the generation of the excitation signal and the acquisition of the dielectric response signal. This technique is useful in the case of relatively fast dynamical measurements when the knowledge of the time evolution of the dielectric constant is needed.

  18. Measuring Accurately Single-Phase Sinusoidal and Non-Sinusoidal Power.

    Science.gov (United States)

    1983-01-01

    dc source. - 1 T Figure 2.2 Power Measuring Test Set-up Source: Robert L. Boylestad , Introductory Circuit Analysis (Ohio: Charles E. Merrill, 1977) p...Power Waveforms for the General Case. Source: Robert L. Boylestad , Introductory CircuitAnalysis (Ohio: Charles E. Merrill, 1968) p. 309. Note that the...Inductive Circuit Source: Robert L. Boylestad , Introductory Circuit Analysis (Ohio: Charles E. Merrill, 1968) p. 43-. and c) In a1 purely capacitive

  19. Three-Signal Method for Accurate Measurements of Depolarization Ratio with Lidar

    Science.gov (United States)

    Reichardt, Jens; Baumgart, Rudolf; McGee, Thomsa J.

    2003-01-01

    A method is presented that permits the determination of atmospheric depolarization-ratio profiles from three elastic-backscatter lidar signals with different sensitivity to the state of polarization of the backscattered light. The three-signal method is insensitive to experimental errors and does not require calibration of the measurement, which could cause large systematic uncertainties of the results, as is the case in the lidar technique conventionally used for the observation of depolarization ratios.

  20. Digital Integrator for Fast Accurate Measurement of Magnetic Flux by Rotating Coils

    CERN Document Server

    Arpaia, P; Spiezia, G

    2007-01-01

    A fast digital integrator (FDI) with dynamic accuracy and a trigger frequency higher than those of a portable digital integrator (PDI), which is a state-of-the-art instrument for magnetic measurements based on rotating coils, was developed for analyzing superconducting magnets in particle accelerators. Results of static and dynamic metrological characterization show how the FDI prototype is already capable of overcoming the dynamic performance of PDI as well as covering operating regions that used to be inaccessible

  1. Accurate measurements of ozone absorption cross-sections in the Hartley band

    OpenAIRE

    2015-01-01

    Ozone plays a crucial role in tropospheric chemistry, is the third largest contributor to greenhouse radiative forcing after carbon dioxide and methane and also a toxic air pollutant affecting human health and agriculture. Long-term measurements of tropospheric ozone have been performed globally for more than 30 years with UV photometers, all relying on the absorption of ozone at the 253.65 nm line of mercury. We have re-determined this cross-section and report a value of 11...

  2. Accurate laser measurements of ozone absorption cross-sections in the Hartley band

    OpenAIRE

    2014-01-01

    Ozone plays a crucial role in tropospheric chemistry, is the third largest contributor to greenhouse radiative forcing after carbon dioxide and methane and also a toxic air pollutant affecting human health and agriculture. Long-term measurements of tropospheric ozone have been performed globally for more than 30 years with UV photometers, all relying on the absorption of ozone at the 253.65 nm line of mercury. We have re-determined this cross-section and rep...

  3. A Robust Method of Vehicle Stability Accurate Measurement Using GPS and INS

    Directory of Open Access Journals (Sweden)

    Miao Zhibin

    2015-12-01

    Full Text Available With the development of the vehicle industry, controlling stability has become more and more important. Techniques of evaluating vehicle stability are in high demand. Integration of Global Positioning System (GPS and Inertial Navigation System (INS is a very practical method to get high-precision measurement data. Usually, the Kalman filter is used to fuse the data from GPS and INS. In this paper, a robust method is used to measure vehicle sideslip angle and yaw rate, which are two important parameters for vehicle stability. First, a four-wheel vehicle dynamic model is introduced, based on sideslip angle and yaw rate. Second, a double level Kalman filter is established to fuse the data from Global Positioning System and Inertial Navigation System. Then, this method is simulated on a sample vehicle, using Carsim software to test the sideslip angle and yaw rate. Finally, a real experiment is made to verify the advantage of this approach. The experimental results showed the merits of this method of measurement and estimation, and the approach can meet the design requirements of the vehicle stability controller.

  4. A technique for fast and accurate measurement of hand volumes using Archimedes' principle.

    Science.gov (United States)

    Hughes, S; Lau, J

    2008-03-01

    A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

  5. Front-end electronics for accurate energy measurement of double beta decays

    Energy Technology Data Exchange (ETDEWEB)

    Gil, A., E-mail: alejandro.gil@ific.uv.es [Instituto de Fisica Corpuscular (CSIC-UV), 46071 Valencia (Spain); Diaz, J.; Gomez-Cadenas, J.J. [Instituto de Fisica Corpuscular (CSIC-UV), 46071 Valencia (Spain); Herrero, V. [Instituto de Instrumentacion para Imagen Molecular (I3M). Centro mixto CSIC, Universitat Politecnica de Valencia, CIEMAT, Valencia (Spain); Rodriguez, J.; Serra, L. [Instituto de Fisica Corpuscular (CSIC-UV), 46071 Valencia (Spain); Toledo, J.; Esteve, R.; Monzo, J.M. [Instituto de Instrumentacion para Imagen Molecular (I3M). Centro mixto CSIC, Universitat Politecnica de Valencia, CIEMAT, Valencia (Spain); Monrabal, F.; Yahlali, N. [Instituto de Fisica Corpuscular (CSIC-UV), 46071 Valencia (Spain)

    2012-12-11

    NEXT, a double beta decay experiment that will operate in Canfranc Underground Laboratory (Spain), aims at measuring the neutrinoless double-{beta} decay of the 136Xe isotope using a TPC filled with enriched Xenon gas at high pressure operated in electroluminescence mode. One technological challenge of the experiment is to achieve resolution better than 1% in the energy measurement using a plane of UV sensitive photomultipliers readout with appropriate custom-made front-end electronics. The front-end is designed to be sensitive to the single photo-electron to detect the weak primary scintillation light produced in the chamber, and also to be able to cope with the electroluminescence signal (several hundred times higher and with a duration of microseconds). For efficient primary scintillation detection and precise energy measurement of the electroluminescent signals the front-end electronics features low noise and adequate amplification. The signal shaping provided allows the digitization of the signals at a frequency as low as 40 MHz.

  6. Optimizing steam flood performance utilizing a new and highly accurate two phase steam measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Huff, B. D.; Warren, P. B. [CalResources LLC (Canada); Whorff, F. [ITT Barton (Canada)

    1995-11-01

    The development of a two phase steam measurement system was documented. The system consists of a `V` cone differential pressure device and a vortex meter velocity device in series through which the steam flows. Temperature and pressure sensors are electronically interfaced with a data logging system. The design was described as being very simple and rugged, consequently, well suited to monitoring in the field.. Steam quality measurements were made in the Kern River Field and the Coalinga Field thermal projects using a surface steam separator. In steam flood operations, steam cost is very high, hence appropriate distribution of the steam can result in significant cost reduction. This technology allows the measurement of steam flow and quality at any point in the steam distribution system. The metering system`s orifice meter was found to have a total average error of 45%, with 25% of that attributable to `cold leg` problem. Installation of the metering system was expected to result in a steam use reduction of 8%, without any impact on production. Steam re-distribution could result in a potential oil production increase of 10%. 12 refs., 8 tabs., 9 figs.

  7. Regular, Fast and Accurate Airborne In-Situ Methane Measurements Around the Tropopause

    Science.gov (United States)

    Dyroff, Christoph; Rauthe-Schöch, Armin; Schuck, Tanja J.; Zahn, Andreas

    2013-04-01

    We present a laser spectrometer for automated monthly measurements of methane (CH4) mixing ratios aboard the CARIBIC passenger aircraft. The instrument is based on a commercial fast methane analyzer (FMA, Los Gatos Res.), which was modified for fully unattended employment. A laboratory characterization was performed and the results with emphasis on the precision, cross sensitivity to H2O, and accuracy are presented. An in-flight calibration strategy is described, that utilizes CH4 measurements obtained from flask samples taken during the same flights. By statistical comparison of the in-situ measurements with the flask samples we derive a total uncetrainty estimate of ~ 3.85 ppbv (1?) around the tropopause, and ~ 12.4 ppbv (1?) during aircraft ascent and descent. Data from the first two years of airborne operation are presented that span a large part of the northern hemispheric upper troposphere and lowermost stratosphere, with occasional crossings of the tropics on flights to southern Africa. With its high spatial resolution and high accuracy this data set is unprecedented in the highly important atmospheric layer of the tropopause.

  8. Accurate mass measurements of $^{26}$Ne, $^{26-30}$Na, $^{29-33}$Mg performed with the MISTRAL spectrometer

    CERN Document Server

    Gaulard, C; Bachelet, C; De Simon, M S; Lunney, M D; Thibault, C; Vieira, N

    2006-01-01

    The minuteness of the nuclear binding energy requires that mass measurements be highly precise and accurate. Here we report on new measurements $^{29-33}$Mg and $^{26}$Na performed with the Mistral mass spectrometer at CERN's Isolde facility. Since mass measurements are prone to systematic errors, considerable effort has been devoted to their evaluation and elimination in order to achieve accuracy and not only precision. We have therefore conducted a campaign of measurements for calibration and error evaluation. As a result, we now have a satisfactory description of the Mistral calibration laws and error budget. We have applied our new understanding to previous measurements of $^{26}$Ne, $^{26-30}$Na and $^{29,32}$Mg for which re-evaluated values are reported.

  9. Reliability of Common Lower Extremity Biomechanical Measures of Children With and Without Obesity.

    Science.gov (United States)

    Tucker, Jennifer; Moore, Megan; Rooy, Julie; Wright, Amy; Rothschild, Carey; Werk, Lloyd N

    2015-01-01

    To determine intrarater and interrater reliability of common measures of lower extremity alignment among children with obesity. The Craig test for femoral anteversion, tibiofemoral angle, Foot Posture Index-6, and sit-and-reach test were performed on 25 children without obesity and 25 children with obesity. Intrarater reliability of all measures in both groups was high. The Craig test demonstrated greatest variability with slight interrater reliability in children who were nonobese [intraclass correlation coefficient [ICC] (95% confidence interval [CI]), 0.372 (-0.051 to 0.6420)] and moderate reliability in children who were obese [ICC (95% CI), 0.527 (0.242 to 0.717)]. Interrater reliability for the tibiofemoral angle and Foot Posture Index-6 was moderate to substantial and for the sit-and-reach test was substantial (ICC >0.99) and highly correlated. Measurement of lower extremity alignment among children with obesity was more reproducible than among children who were not obese. Measures of lower extremity alignment and general flexibility in children with obesity are both reproducible and reliable.

  10. Examining factors that may influence accurate measurement of testosterone in sea turtles.

    Science.gov (United States)

    Graham, Katherine M; Mylniczenko, Natalie D; Burns, Charlene M; Bettinger, Tammie L; Wheaton, Catharine J

    2016-01-01

    Differences in reported testosterone concentrations in male sea turtle blood samples are common in the veterinary literature, but may be accounted for by differences in sample handling and processing prior to assay. Therefore, our study was performed to determine best practices for testosterone analysis in male sea turtles (Caretta caretta and Chelonia mydas). Blood samples were collected into 5 collection tube types, and assay validation and measured testosterone concentrations were compared across different sample storage (fresh, refrigerated 1 week, or frozen), extraction (unextracted or ether-extracted), and processing treatment (untreated, homogenized, or dissociation reagent) conditions. Ether-extracted and dissociation reagent-treated samples validated in all conditions tested and are recommended for use, as unextracted samples validated only if assayed fresh. Dissociation reagent treatment was simpler to perform than ether extraction and resulted in total testosterone concentrations ~2.7-3.5 times greater than free testosterone measured in ether-extracted samples. Sample homogenization did not affect measured testosterone concentrations, and could be used to increase volume in gelled samples. An annual seasonal testosterone increase was observed in both species when ether extraction or dissociation reagent treatment was used. Annual deslorelin implant treatments in a Chelonia mydas male resulted in suppression of seasonal testosterone following the fourth treatment. Seasonal testosterone patterns resumed following discontinuation of deslorelin. Comparison of in-house and commercially available enzyme immunoassay kits revealed similar patterns of seasonal testosterone increases and deslorelin-induced suppression. Our study highlights the importance of methodological validation and provides laboratorians with best practices for testosterone enzyme immunoassay in sea turtles.

  11. Accurate mass measurements of short-lived isotopes with the MISTRAL rf spectrometer

    CERN Document Server

    Toader, C F; Borcea, C; Doubre, H; Duma, M; Jacotin, M; Henry, S; Képinski, J F; Lebée, G; Le Scornet, G; Lunney, M D; Monsanglant, C; De Saint-Simon, M; Thibault, C

    1999-01-01

    The MISTRAL experiment has measured its first masses at ISOLDE. Installed in May 1997, this radiofrequency transmission spectrometer is to concentrate on nuclides with particularly short half-lives. MISTRAL received its first stable beam in October and first radioactive beam in November 1997. These first tests, with a plasma ion source, resulted in excellent isobaric separation and reasonable transmission. Further testing and development enabled first data taking in July 1998 on neutron-rich Na isotopes having half-lives as short as 31 ms.

  12. Individual-Based Allometric Equations Accurately Measure Carbon Storage and Sequestration in Shrublands

    Directory of Open Access Journals (Sweden)

    Norman W.H. Mason

    2014-02-01

    Full Text Available Many studies have quantified uncertainty in forest carbon (C storage estimation, but there is little work examining the degree of uncertainty in shrubland C storage estimates. We used field data to simulate uncertainty in carbon storage estimates from three error sources: (1 allometric biomass equations; (2 measurement errors of shrubs harvested for the allometry; and (3 measurement errors of shrubs in survey plots. We also assessed uncertainty for all possible combinations of these error sources. Allometric uncertainty had the greatest independent effect on C storage estimates for individual plots. The largest error arose when all three error sources were included in simulations (where the 95% confidence interval spanned a range equivalent to 40% of mean C storage. Mean C sequestration (1.73 Mg C ha–1 year–1 exceeded the margin of error produced by the simulated sources of uncertainty. This demonstrates that, even when the major sources of uncertainty were accounted for, we were able to detect relatively modest gains in shrubland C storage.

  13. Accurate low-rank matrix recovery from a small number of linear measurements

    CERN Document Server

    Candes, Emmanuel J

    2009-01-01

    We consider the problem of recovering a lowrank matrix M from a small number of random linear measurements. A popular and useful example of this problem is matrix completion, in which the measurements reveal the values of a subset of the entries, and we wish to fill in the missing entries (this is the famous Netflix problem). When M is believed to have low rank, one would ideally try to recover M by finding the minimum-rank matrix that is consistent with the data; this is, however, problematic since this is a nonconvex problem that is, generally, intractable. Nuclear-norm minimization has been proposed as a tractable approach, and past papers have delved into the theoretical properties of nuclear-norm minimization algorithms, establishing conditions under which minimizing the nuclear norm yields the minimum rank solution. We review this spring of emerging literature and extend and refine previous theoretical results. Our focus is on providing error bounds when M is well approximated by a low-rank matrix, and ...

  14. Recent Advances in Highly Accurate Range Measurements with TerraSAR-X

    Science.gov (United States)

    Eineder, Michael; Balss, Ulrich; Gisinger, Christoph; Cong, Xiao Ying; Brcic, Ramon; Steigenberger, Peter

    2013-04-01

    Earth surface displacement measurement from space using Synthetic Aperture Radar (SAR) imagery is an interesting alternative to SAR interferometry (InSAR). The advantages are that 2D information can be retrieved (InSAR only 1D), absolute displacements can be retrieved (no reference point required) and it is very robust (phase unwrapping not required). On the other hand, the accuracy is limited by the pixel resolution, the object contrast, the orbit accuracy, by wave propagation distortion and by geodetic effects. Therefore the accuracy was more in the meter / decimeter level in the past, compared to millimeter accuracy of InSAR. During the recent years our team established a test and validation site at the geodetic observatory Wettzell, Germany and developed compensation methods to reduce the overall error of absolute range measurements from decimeters to only one centimeter. The methods include correction of dry and wet atmospheric delays, ionospheric corrections, solid earth tides, continental drift, atmospheric pressure loading and ocean tidal loading. For more one year a radar reflector was monitored and each image evaluated. Our presentation gives and overview of methods and achieved results. Futhermore, examples of real world applications and an outlook on more applications is given such as phase unwrapping augmentation.

  15. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn [Physics Department, Carleton University, Ottawa, Ontario K1S 5B6, Canada and Cardiology, The University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada)

    2016-01-15

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE

  16. Bra band size measurements derived from three-dimensional scans are not accurate in women with large, ptotic breasts.

    Science.gov (United States)

    McGhee, Deirdre E; Ramsay, Lauren G; Coltman, Celeste E; Gho, Sheridan A; Steele, Julie R

    2017-07-12

    This study investigated differences in standard measurements used to determine bra size, under-bust chest circumference (UBCC) and over-bust chest circumference (OBCC), measured from a three-dimensional scan (hand-held scanner) compared to the direct measurement in 111 women (age 21-56 years; right breast volume 57-1672 mL; bra size 10A-18G). Bland-Altman plots of UBCC measurements showed a large positive bias and wide limits of agreement (12 cm; -4.6 to 28 cm), which increased as band size increased but decreased when the breasts were digitally removed from the scan prior to the UBCC measurement. The difference in UBCC measurements determined from scans compared to direct measurement had a strong positive correlation with breast volume and breast ptotis. The OBCC measurements showed a small positive bias (2.4 cm; -3.4 to 8.4), consistent across the range of bra sizes. Bra band size measurements determined from three-dimensional scans can be inaccurate in women with large, ptotic breasts. Practitioner Summary: We investigated potential errors in anthropometric data derived from three-dimensional scans used for bra design and fit. Bra band size measurements taken from three-dimensional scans were over-estimated in women with large breasts, whereas bra cup size measurements were accurate to within one-cup size across the entire range of bra sizes.

  17. Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.

    Science.gov (United States)

    Cruz, Antonio M; Maninchedda, Ugo E; Burger, Dominik; Wanda, Sabine; Vidondo, Beatriz

    2017-09-01

    OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.

  18. Accurate fault location algorithm on power transmission lines with use of two-end unsynchronized measurements

    Directory of Open Access Journals (Sweden)

    Mohamed Dine

    2012-01-01

    Full Text Available This paper presents a new approach to fault location on power transmission lines. This approach uses two-end unsynchronised measurements of the line and benefits from the advantages of digital technology and numerical relaying, which are available today and can easily be applied for off-line analysis. The approach is to modify the apparent impedance method using a very simple first-order formula. The new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays is sufficiently small enough to be transmitted easily using a digital protection channel. The proposed approach is tested via digital simulation using MATLand the applied test results corroborate the superior performance of the proposed approach.

  19. Analysis of Partial Volume Effects on Accurate Measurement of the Hippocampus Volume

    Institute of Scientific and Technical Information of China (English)

    Maryam Hajiesmaeili; Jamshid Dehmeshki; Tim Ellis

    2014-01-01

    Hippocampal volume loss is an important biomarker in distinguishing subjects with Alzheimer’s disease (AD) and its measurement in magnetic resonance images (MRI) is influenced by partial volume effects (PVE). This paper describes a post-processing approach to quantify PVE for correction of the hippocampal volume by using a spatial fuzzyC-means (SFCM) method. The algorithm is evaluated on a dataset of 20 T1-weighted MRI scans sampled at two different resolutions. The corrected volumes for left and right hippocampus (HC) which are 23% and 18% for the low resolution and 6% and 5% for the high resolution datasets, respectively are lower than hippocampal volume results from manual segmentation. Results show the importance of applying this technique in AD detection with low resolution datasets.

  20. Accurate Simulation of 802.11 Indoor Links: A "Bursty" Channel Model Based on Real Measurements

    Directory of Open Access Journals (Sweden)

    Agüero Ramón

    2010-01-01

    Full Text Available We propose a novel channel model to be used for simulating indoor wireless propagation environments. An extensive measurement campaign was carried out to assess the performance of different transport protocols over 802.11 links. This enabled us to better adjust our approach, which is based on an autoregressive filter. One of the main advantages of this proposal lies in its ability to reflect the "bursty" behavior which characterizes indoor wireless scenarios, having a great impact on the behavior of upper layer protocols. We compare this channel model, integrated within the Network Simulator (ns-2 platform, with other traditional approaches, showing that it is able to better reflect the real behavior which was empirically assessed.

  1. Validation of the SF-6D Health State Utilities Measure in Lower Extremity Sarcoma

    Directory of Open Access Journals (Sweden)

    Kenneth R. Gundle

    2014-01-01

    Full Text Available Aim. Health state utilities measures are preference-weighted patient-reported outcome (PRO instruments that facilitate comparative effectiveness research. One such measure, the SF-6D, is generated from the Short Form 36 (SF-36. This report describes a psychometric evaluation of the SF-6D in a cross-sectional population of lower extremity sarcoma patients. Methods. Patients with lower extremity sarcoma from a prospective database who had completed the SF-36 and Toronto Extremity Salvage Score (TESS were eligible for inclusion. Computed SF-6D health states were given preference weights based on a prior valuation. The primary outcome was correlation between the SF-6D and TESS. Results. In 63 pairs of surveys in a lower extremity sarcoma population, the mean preference-weighted SF-6D score was 0.59 (95% CI 0.4–0.81. The distribution of SF-6D scores approximated a normal curve (skewness = 0.11. There was a positive correlation between the SF-6D and TESS (r=0.75, P<0.01. Respondents who reported walking aid use had lower SF-6D scores (0.53 versus 0.61, P=0.03. Five respondents underwent amputation, with lower SF-6D scores that approached significance (0.48 versus 0.6, P=0.06. Conclusions. The SF-6D health state utilities measure demonstrated convergent validity without evidence of ceiling or floor effects. The SF-6D is a health state utilities measure suitable for further research in sarcoma patients.

  2. Standardization of vitrinite reflectance measurements in shale petroleum systems: How accurate are my Ro data?

    Science.gov (United States)

    Hackley, Paul C.

    2014-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708-11: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (Ro 0.31-1.53%), from organic-rich to organic-lean (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability values (difference between repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility values (difference between results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping the other components. Discussion among

  3. S3 HMBC hetero: Spin-State-Selective HMBC for accurate measurement of long-range heteronuclear coupling constants

    Science.gov (United States)

    Hoeck, Casper; Gotfredsen, Charlotte H.; Sørensen, Ole W.

    2017-02-01

    A novel method, Spin-State-Selective (S3) HMBC hetero, for accurate measurement of heteronuclear coupling constants is introduced. The method extends the S3 HMBC technique for measurement of homonuclear coupling constants by appending a pulse sequence element that interchanges the polarization in 13C-1H methine pairs. This amounts to converting the spin-state selectivity from 1H spin states to 13C spin states in the spectra of long-range coupled 1H spins, allowing convenient measurement of heteronuclear coupling constants similar to other S3 or E.COSY-type methods. As usual in this type of techniques, the accuracy of coupling constant measurement is independent of the size of the coupling constant of interest. The merits of the new method are demonstrated by application to vinyl acetate, the alkaloid strychnine, and the carbohydrate methyl β-maltoside.

  4. An X-Band Waveguide Measurement Technique for the Accurate Characterization of Materials with Low Dielectric Loss Permittivity

    CERN Document Server

    Allen, Kenneth W; Reid, David R; Bean, Jeffrey A; Ellis, Jeremy D; Morris, Andrew P; Marsh, Jeramy M

    2016-01-01

    In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically-long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S21) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S21 measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis of our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10e-3 for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. ...

  5. Quantitative assessment based on kinematic measures of functional impairments during upper extremity movements: A review.

    Science.gov (United States)

    de los Reyes-Guzmán, Ana; Dimbwadyo-Terrer, Iris; Trincado-Alonso, Fernando; Monasterio-Huelin, Félix; Torricelli, Diego; Gil-Agudo, Angel

    2014-08-01

    Quantitative measures of human movement quality are important for discriminating healthy and pathological conditions and for expressing the outcomes and clinically important changes in subjects' functional state. However the most frequently used instruments for the upper extremity functional assessment are clinical scales, that previously have been standardized and validated, but have a high subjective component depending on the observer who scores the test. But they are not enough to assess motor strategies used during movements, and their use in combination with other more objective measures is necessary. The objective of the present review is to provide an overview on objective metrics found in literature with the aim of quantifying the upper extremity performance during functional tasks, regardless of the equipment or system used for registering kinematic data. A search in Medline, Google Scholar and IEEE Xplore databases was performed following a combination of a series of keywords. The full scientific papers that fulfilled the inclusion criteria were included in the review. A set of kinematic metrics was found in literature in relation to joint displacements, analysis of hand trajectories and velocity profiles. These metrics were classified into different categories according to the movement characteristic that was being measured. These kinematic metrics provide the starting point for a proposed objective metrics for the functional assessment of the upper extremity in people with movement disorders as a consequence of neurological injuries. Potential areas of future and further research are presented in the Discussion section. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Accurate Measurements of Free Flight Drag Coefficients with Amateur Doppler Radar

    CERN Document Server

    Courtney, Elya; Courtney, Michael

    2016-01-01

    In earlier papers, techniques have been described using optical chronographs to determine free flight drag coefficients with an accuracy of 1-2%, accomplished by measuring near and far velocities of projectiles in flight over a known distance. Until recently, Doppler radar has been prohibitively expensive for many users. This paper reports results of exploring potential applications and accuracy using a recently available, inexpensive (< $600 US) amateur Doppler radar system to determine drag coefficients for projectiles of various sizes (4.4 mm to 9 mm diameter) and speeds (M0.3 to M3.0). In many cases, drag coefficients can be determined with an accuracy of 1% or better if signal-to-noise ratio is sufficient and projectiles vary little between trials. It is also straightforward to design experiments for determining drag over a wide range of velocities. Experimental approaches and limitations are described. Overall, the amateur radar system shows greater accuracy, ease of use, and simplicity compared with...

  7. Accurate modeling of antennas for radiating short pulses, FDTD analysis and experimental measurements

    Science.gov (United States)

    Maloney, James G.; Smith, Glenn S.

    1993-01-01

    Antennas used to radiate short pulses often require different design rules that those that are used to radiate essentially time-harmonic signals. The finite-difference time-domain (FDTD) method is a very flexible numerical approach that can be used to treat a variety of electromagnetic problems in the time domain. It is well suited to the analysis and design of antennas for radiating short pulses; however, several advances had to be made before the method could be applied to this problem. In this paper, we will illustrate the use of the FDTD method with two antennas designed for the radiation of short pulses. The first is a simple, two-dimensional geometry, and open-ended parallel-plate waveguide, while the second is a three-dimensional, rotationally symmetric geometry, a conical monopole fed through an image by a coaxial transmission line. Both antennas are 'optimized' according to given criteria by adjusting geometrical parameters and including resistive loading that varies continuously with position along the antenna. The predicted performance for the conical monopole antenna is compared with experimental measurements; this verifies the optimization and demonstrates the practicality of the design.

  8. Accurate electrical resistance measurement of the crystallization kinetics of amorphous alloys

    Institute of Scientific and Technical Information of China (English)

    WANG; Yaping

    2001-01-01

    [1]Kobayashi, H.?Yasukochi, K., Maximum and minimum heat flux and temperature fluctuation in film-boiling states in superfluid helium, Adv. Cryog. Eng., 1980, 25: 372.[2]Kobayashi, H.?Yasukochi, K., A sample configuration effect on the heat transfer from metal surfaces to pressurized He II, Proc. ICEC, 1980, 8: 217.[3]Schwerdtner, M. V., Stamm, G., Tosi, A. N. et al. The boiling-up process in He II. Optical measurements and visualization, Cryogenics, 1992, 32: 775.[4]Schwerdtner, M. V., Poppes, W., Schmidt, D. W., Distortion of temperature signals in He II due to probe geometry, and a new improved probe, Cryogenics, 1989, 29: 132.[5]Shimazaki, T., Murakami, M.?Iida, T., Second sound wave heat transfer, thermal boundary layer formation and boiling: highly transient heat transport phenomena in He II, Cryogenics, 1995, 35: 645.[6]Zhang, P., Study of physical mechanism of film boiling in He II, Doctoral dissertation, Shanghai Jiaotong University, China, 1998.[7]Arp, V., State equation of liquid helium-4 from 0.8 to 2.5K, J. Low Temp. Phys., 1990, 79: 93.[8]Zhang, P., Kimura, S., Murakami, M. et al., Non-planar and non-linear second sound wave in He II, Chinese Physics Letters, 2000, 17: 43.

  9. Accurate measurement of the sticking time and sticking probability of Rb atoms on a polydimethylsiloxane coating

    Energy Technology Data Exchange (ETDEWEB)

    Atutov, S. N., E-mail: atutovsn@mail.ru; Plekhanov, A. I. [Russian Academy of Sciences, Institute of Automation and Electrometry, Siberian Branch (Russian Federation)

    2015-01-15

    We present the results of a systematic study of Knudsen’s flow of Rb atoms in cylindrical capillary cells coated with a polydimethylsiloxane (PDMS) compound. The purpose of the investigation is to determine the characterization of the coating in terms of the sticking probability and sticking time of Rb on the two types of coating of high and medium viscosities. We report the measurement of the sticking probability of a Rb atom to the coating equal to 4.3 × 10{sup −5}, which corresponds to the number of bounces 2.3 × 10{sup 4} at room temperature. These parameters are the same for the two kinds of PDMS used. We find that at room temperature, the respective sticking times for high-viscosity and medium-viscosity PDMS are 22 ± 3 μs and 49 ± 6 μs. These sticking times are about million times larger than the sticking time derived from the surface Rb atom adsorption energy and temperature of the coating. A tentative explanation of this surprising result is proposed based on the bulk diffusion of the atoms that collide with the surface and penetrate inside the coating. The results can be important in many resonance cell experiments, such as the efficient magnetooptical trapping of rare elements or radioactive isotopes and in experiments on the light-induced drift effect.

  10. Novel methodology for accurate resolution of fluid signatures from multi-dimensional NMR well-logging measurements.

    Science.gov (United States)

    Anand, Vivek

    2017-03-01

    A novel methodology for accurate fluid characterization from multi-dimensional nuclear magnetic resonance (NMR) well-logging measurements is introduced. This methodology overcomes a fundamental challenge of poor resolution of features in multi-dimensional NMR distributions due to low signal-to-noise ratio (SNR) of well-logging measurements. Based on an unsupervised machine-learning concept of blind source separation, the methodology resolves fluid responses from simultaneous analysis of large quantities of well-logging data. The multi-dimensional NMR distributions from a well log are arranged in a database matrix that is expressed as the product of two non-negative matrices. The first matrix contains the unique fluid signatures, and the second matrix contains the relative contributions of the signatures for each measurement sample. No a priori information or subjective assumptions about the underlying features in the data are required. Furthermore, the dimensionality of the data is reduced by several orders of magnitude, which greatly simplifies the visualization and interpretation of the fluid signatures. Compared to traditional methods of NMR fluid characterization which only use the information content of a single measurement, the new methodology uses the orders-of-magnitude higher information content of the entire well log. Simulations show that the methodology can resolve accurate fluid responses in challenging SNR conditions. The application of the methodology to well-logging data from a heavy oil reservoir shows that individual fluid signatures of heavy oil, water associated with clays and water in interstitial pores can be accurately obtained. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. PRISM, a Patient-Reported Outcome Instrument, Accurately Measures Symptom Change in Refractory Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Fuller, Garth; Bolus, Roger; Whitman, Cynthia; Talley, Jennifer; Erder, M Haim; Joseph, Alain; Silberg, Debra G; Spiegel, Brennan

    2017-03-01

    Most patients with gastroesophageal reflux disease (GERD) experience relief following treatment with proton pump inhibitors (PPIs) (Vakil et al. in Am J Gastroenterol 101:1900-1920, 2006; Everhart and Ruhl in Gastroenterology 136:376-386, 2009). As many as 17-44% of patients, however, exhibit only partial response to therapy. Most extant GERD patient-reported outcome (PRO) instruments fail to meet development best practices as described by the FDA (Talley and Wiklund in Qual Life Res 14:21-33, 2005; Van Pinxteren et al. in Cochrane Database Syst Rev 18:CD002095, 2004; El-Serag et al. in Aliment Pharmacol Ther 32:720-737, 2010). To develop and validate a PRO instrument for clinical trials involving patients with GERD who are PPI partial responders. We prepared a systematic literature review, held patient focus groups, convened an expert panel, and conducted cognitive interviews to establish content validity. Eligible participants took PPI therapy for at least 8 weeks, had undergone an upper endoscopy, and scored at least 8 points on the GerdQ [6]. Qualitative data guided development of 26 draft items. Items were reviewed by expert panels and debriefed with patients. The resulting 21-item instrument underwent psychometric evaluation during a Phase IIB trial. During the trial, confirmatory factor analysis (n = 220) resulted in a four-factor model displaying the highest goodness of fit. All domains had a high inter-item correlation (Cronbach's α > 0.8). Test-retest reliability and convergent validity were strong, with highly significant (p PRISM scores and severity anchors and significant (p PRISM. Developed in line with FDA guidance on PROs, PRISM represents an important new outcome measure for patients with GERD with a partial response to PPI therapy.

  12. Non-invasive accurate measurement of arterial PCO2 in a pediatric animal model.

    Science.gov (United States)

    Fierstra, Jorn; Winter, Jeff D; Machina, Matthew; Lukovic, Jelena; Duffin, James; Kassner, Andrea; Fisher, Joseph A

    2013-04-01

    The PCO2 in arterial blood (PaCO2) is a good parameter for monitoring ventilation and acid-base changes in ventilated patients, but its measurement is invasive and difficult to obtain in small children. Attempts have been made to use the partial pressure of CO2 in end-tidal gas (PETCO2), as a noninvasive surrogate for PaCO2. Studies have revealed that, unfortunately, the differences between PETCO2 and PaCO2 are too variable to be clinically useful. We hypothesized that end-inspiratory rebreathing, previously shown to equalize PETCO2 and PaCO2 in spontaneously breathing humans, would also be effective with positive pressure ventilation. Eight newborn Yorkshire pigs were mechanically ventilated via a partial rebreathing circuit to implement end-inspiratory rebreathing. Arterial blood was sampled and tested for PaCO2. A variety of alveolar ventilations resulting in different combinations of end-tidal PCO2 (30-50 mmHg) and PO2 (35-500 mmHg) were tested for differences between PETCO2 and PaCO2 (PET-aCO2). The PET-aCO2 of all samples was (mean ± 1.96 SD) 0.4 ± 2.7 mmHg. Our study demonstrates that, in ventilated juvenile animals, end-inspiratory rebreathing maintains PET-aCO2 to what would be a clinically useful range. If verified clinically, this approach could open the way for non-invasive monitoring of arterial PCO2 in critically ill patients.

  13. Patient safety measures in burn care: do National reporting systems accurately reflect quality of burn care?

    Science.gov (United States)

    Mandell, Samuel P; Robinson, Ellen F; Cooper, Claudette L; Klein, Matthew B; Gibran, Nicole S

    2010-01-01

    UHC CDB provide a potential to benchmark quality of care. However, reporting quality data for trauma and burns requires stringent understanding of injury data collection. Although quality measures are important for improving patient safety and establishing benchmarks for complication and mortality rates, caution must be taken when applying them to specific product lines.

  14. Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review

    NARCIS (Netherlands)

    E. van Trijffel; R.J. van de Pol; R.A. Oostendorp; C. Lucas

    2010-01-01

    Question: What is the inter-rater reliability for measurements of passive physiological or accessory movements in lower extremity joints? Design: Systematic review of studies of inter-rater reliability. Participants: Individuals with and without lower extremity disorders. Outcome measures: Range of

  15. Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review.

    NARCIS (Netherlands)

    Trijffel, E. van; Pol, R.J. van de; Oostendorp, R.A.B.; Lucas, C.

    2010-01-01

    QUESTION: What is the inter-rater reliability for measurements of passive physiological or accessory movements in lower extremity joints? DESIGN: Systematic review of studies of inter-rater reliability. PARTICIPANTS: Individuals with and without lower extremity disorders. OUTCOME MEASURES: Range of

  16. Extreme Value Statistical Characterization of Time Domain Pulse-to-Pulse Measurements

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Martino, Michele

    2015-01-01

    An analytical method, based on Extreme Value Theory (EV T), for predicting the worst case repeatability of time domain pulse-to-pulse measurements, modeled as independent and identically distributed random variables, is proposed. The method allows the use of the noise level of a measurement system for predicting the upcoming peak values over a given number of independent observations. The proposed analytical model is compared against simulated distributions generated in Matlab, highlighting satisfying match for any sample size.The simulations are based on a case study on the characterization of a pulsed power supply for the klystron modulators of the Compact LInear Collider (CLIC) under study at CERN.

  17. Rheological Properties of Extreme Pressure Greases Measured Using a Process Control Rheometer

    DEFF Research Database (Denmark)

    Glasscock, Julie; Smith, Robin S.

    2012-01-01

    A new process control rheometer (PCR) designed for use in industrial process flows has been used to measure the rheological properties of three extreme-pressure greases. The rheometer is a robust yet sensitive instrument designed to operate in an industrial processing environment in either in......-line or on-line configurations. The PCR was able to measure the rheological properties including the elastic modulus, viscous modulus, and complex viscosity of the greases which in an industrial flow application could be used as variables in a feedback system to control the process and the quality...

  18. A Two-Sinker Densimeter for Accurate Measurements of the Density of Natural Gases at Standard Conditions

    Science.gov (United States)

    Richter, Markus; Kleinrahm, Reiner; Glos, Stefan; Wagner, Wolfgang; Span, Roland; Schley, Peter; Uhrig, Martin

    2010-05-01

    A special reference densimeter has been developed for accurate measurements of densities of natural gases and multicomponent gas mixtures at standard conditions of temperature and pressure ( T s = 273.15 K and p s = 0.101325 MPa). The densimeter covers the range from 0.7 kg · m-3 to 1.3 kg · m-3; the total measurement uncertainty in density is 0.020 % (95 % level of confidence). The measurement principle used is the two-sinker method, which is based on the Archimedes buoyancy principle. The certified calibration laboratory of E.ON Ruhrgas AG, Germany, uses this densimeter to verify the standard densities of certified calibration gases (binary and multicomponent gas mixtures). Moreover, the densimeter is used to determine the compositions of commercially available binary gas mixtures with a small uncertainty of (0.01-0.03) mol%.

  19. An accurate measurement of the anisotropies and mean level of the Cosmic Infrared Background at 100 and 160 um

    CERN Document Server

    Pénin, Aurélie; Noriega-Crepo, Alberto; Grain, Julien; Miville-Deschênes, Marc-Antoine; Ponthieu, Nicolas; Martin, Peter; Blagrave, Kevin; Lockman, Felix J

    2011-01-01

    The anisotropies of the cosmic infrared background (CIB) are a powerful tool to study the evolution of galaxies and large-scale structures. However one of the main limitations to an accurate measurement is the contamination by Galactic dust emission. Our goal is to show that we can remove the Galactic cirrus contamination using HI data, and thus measure accurately the clustering of starburst galaxies in the CIB. We use observations of the extragalactic N1 field at far-infrared (100 and 160 um) and radio (21 cm) wavelengths. We compute the correlation between dust emission, as traced by far-infrared observations, and HI gas, and derive dust emissivities which enable us to subtract the cirrus emission from the far-infrared maps. We then derive the power spectrum of the CIB anisotropies and its mean level. We compute dust emissivities for each of the HI-velocity components. Using IRIS/IRAS data at 100 um, we demonstrate that we can use the measured emissivities to determine and remove the cirrus contribution to ...

  20. Accurate measurement of dispersion data through short and narrow tubes used in very high-pressure liquid chromatography.

    Science.gov (United States)

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2015-09-04

    An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short Ldispersion in vHPLC; however, their dispersion characteristics cannot be accurately measured at such flow rates due to system dispersion contribution of vHPLC injector and detector. It is shown that using longer and wider tubes (>10μL) enables a reliable measurement of the dispersion data. We confirmed that the dimensionless plot of the reduced dispersion coefficient versus the reduced linear velocity (Peclet number) depends on the aspect ratio, L/rc, of the tube, and unexpectedly also on the diffusion coefficient of the analyte. This dimensionless plot could be easily obtained for a large volume tube, which has the same aspect ratio as that of the short and narrow tube, and for the same diffusion coefficient. The dispersion data for the small volume tube are then directly extrapolated from this plot. For instance, it is found that the maximum volume variances of 75μm×30.5cm and 100μm×30.5cm prototype finger-tightened connecting tubes are 0.10 and 0.30μL(2), respectively, with an accuracy of a few percent and a precision smaller than seven percent. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Measurement of the angular position of a human extremity based on a multifunctional approach

    Science.gov (United States)

    Quan, Wei; Shida, Katsunori

    2007-07-01

    A novel method for measuring the three-dimensional joint angles of a human extremity simultaneously is presented based on a multifunctional sensing approach. The method proposes a simple and single configuration with minimum sensing elements, which is able to convert obliquity, bending direction and torsion angle to the linear movements of three wires by imitating the status of the skin on the joint using a flexible tube. A prototype is built with three inductances as its outputs, whose results examine the feasibility of the proposed method and give satisfactory accuracy. A simple algorithm to reconstruct three angular parameters is able to provide real-time analysis. The system is multifunctional, easily mountable, low cost and can be used for long-term monitoring of human extremities such as the arm, knee and shoulder.

  2. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS technique

    Directory of Open Access Journals (Sweden)

    H. Chen

    2012-09-01

    Full Text Available Accurate measurements of carbon monoxide (CO in humid air have been made using the cavity ring-down spectroscopy (CRDS technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near infrared region (∼1.57 μm after removing interferences from adjacent carbon dioxide (CO2 and water vapor (H2O absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360–390 ppm. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately −0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of −0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs new spectroscopic analysis (available since the beginning of 2012 indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  3. MACS-Himalaya: A photogrammetric aerial oblique camera system designed for highly accurate 3D-reconstruction and monitoring in steep terrain and under extreme illumination conditions

    Science.gov (United States)

    Brauchle, Joerg; Berger, Ralf; Hein, Daniel; Bucher, Tilman

    2017-04-01

    The DLR Institute of Optical Sensor Systems has developed the MACS-Himalaya, a custom built Modular Aerial Camera System specifically designed for the extreme geometric (steep slopes) and radiometric (high contrast) conditions of high mountain areas. It has an overall field of view of 116° across-track consisting of a nadir and two oblique looking RGB camera heads and a fourth nadir looking near-infrared camera. This design provides the capability to fly along narrow valleys and simultaneously cover ground and steep valley flank topography with similar ground resolution. To compensate for extreme contrasts between fresh snow and dark shadows in high altitudes a High Dynamic Range (HDR) mode was implemented, which typically takes a sequence of 3 images with graded integration times, each covering 12 bit radiometric depth, resulting in a total dynamic range of 15-16 bit. This enables dense image matching and interpretation for sunlit snow and glaciers as well as for dark shaded rock faces in the same scene. Small and lightweight industrial grade camera heads are used and operated at a rate of 3.3 frames per second with 3-step HDR, which is sufficient to achieve a longitudinal overlap of approximately 90% per exposure time at 1,000 m above ground at a velocity of 180 km/h. Direct georeferencing and multitemporal monitoring without the need of ground control points is possible due to the use of a high end GPS/INS system, a stable calibrated inner geometry of the camera heads and a fully photogrammetric workflow at DLR. In 2014 a survey was performed on the Nepalese side of the Himalayas. The remote sensing system was carried in a wingpod by a Stemme S10 motor glider. Amongst other targets, the Seti Valley, Kali-Gandaki Valley and the Mt. Everest/Khumbu Region were imaged at altitudes up to 9,200 m. Products such as dense point clouds, DSMs and true orthomosaics with a ground pixel resolution of up to 15 cm were produced in regions and outcrops normally inaccessible to

  4. Correction of SOHO CELIAS/SEM EUV Measurements saturated by extreme solar flare events

    CERN Document Server

    Didkovsky, L V; Jones, A R; Wieman, S; Tsurutani, B T; McMullin, D

    2006-01-01

    The solar irradiance in the Extreme Ultraviolet (EUV) spectral bands has been observed with a 15 sec cadence by the SOHO Solar EUV Monitor (SEM) since 1995. During remarkably intense solar flares the SEM EUV measurements are saturated in the central (zero) order channel (0.1 -- 50.0 nm) by the flare soft X-ray and EUV flux. The first order EUV channel (26 -- 34 nm) is not saturated by the flare flux because of its limited bandwidth, but it is sensitive to the arrival of Solar Energetic Particles (SEP). While both channels detect nearly equal SEP fluxes, their contributions to the count rate is sensibly negligible in the zero order channel but must be accounted for and removed from the first channel count rate. SEP contribution to the measured SEM signals usually follows the EUV peak for the gradual solar flare events. Correcting the extreme solar flare SEM EUV measurements may reveal currently unclear relations between the flare magnitude, dynamics observed in different EUV spectral bands, and the measured Ea...

  5. An accurate Rb density measurement method for a plasma wakefield accelerator experiment using a novel Rb reservoir

    Energy Technology Data Exchange (ETDEWEB)

    Öz, E.; Batsch, F.; Muggli, P.

    2016-09-01

    A method to accurately measure the density of Rb vapor is described. We plan on using this method for the Advanced Wakefield (AWAKE) (Assmann et al., 2014 [1]) project at CERN , which will be the world's first proton driven plasma wakefield experiment. The method is similar to the hook (Marlow, 1967 [2]) method and has been described in great detail in the work by Hill et al. (1986) [3]. In this method a cosine fit is applied to the interferogram to obtain a relative accuracy on the order of 1% for the vapor density–length product. A single-mode, fiber-based, Mach–Zenhder interferometer will be built and used near the ends of the 10 meter-long AWAKE plasma source to be able to make accurate relative density measurement between these two locations. This can then be used to infer the vapor density gradient along the AWAKE plasma source and also change it to the value desired for the plasma wakefield experiment. Here we describe the plan in detail and show preliminary results obtained using a prototype 8 cm long novel Rb vapor cell.

  6. Mixed sand and gravel beaches: accurate measurement of active layer depth and sediment transport volumes using PIT tagged tracer pebbles

    Science.gov (United States)

    Holland, A.; Moses, C.; Sear, D. A.; Cope, S.

    2016-12-01

    As sediments containing significant gravel portions are increasingly used for beach replenishment projects globally, the total number of beaches classified as `mixed sand and gravel' (MSG) increases. Calculations for required replenishment sediment volumes usually assume a uniform layer of sediment transport across and along the beach, but research into active layer (AL) depth has shown variations both across shore and according to sediment size distribution. This study addresses the need for more accurate calculations of sediment transport volumes on MSG beaches by using more precise measurements of AL depth and width, and virtual velocity of tracer pebbles. Variations in AL depth were measured along three main profile lines (from MHWS to MLWN) at Eastoke, Hayling Island (Hampshire, UK). Passive Integrated Transponder (PIT) tagged pebbles were deployed in columns, and their new locations repeatedly surveyed with RFID technology. These data were combined with daily dGPS beach profiles and sediment sampling for detailed analysis of the influence of beach morphodynamics on sediment transport volumes. Data were collected over two consecutive winter seasons: 2014-15 (relatively calm, average wave height sandy lower foreshore reduced the AL to 10% of wave height in this area. The disparity in AL depth across the beach profile indicates that traditional models are not accurately representing bulk sediment transport on MSG beaches. It is anticipated that by improving model inputs, beach managers will be better able to predict necessary volumes and sediment grain size proportions of replenishment material for effective management of MSG beaches.

  7. An accurate Rb density measurement method for a plasma wakefield accelerator experiment using a novel Rb reservoir

    CERN Document Server

    Öz, E; Muggli, P

    2016-01-01

    A method to accurately measure the density of Rb vapor is described. We plan on using this method for the Advanced Wakefield (AWAKE)~\\cite{bib:awake} project at CERN , which will be the world's first proton driven plasma wakefield experiment. The method is similar to the hook~\\cite{bib:Hook} method and has been described in great detail in the work by W. Tendell Hill et. al.~\\cite{bib:densitymeter}. In this method a cosine fit is applied to the interferogram to obtain a relative accuracy on the order of $1\\%$ for the vapor density-length product. A single-mode, fiber-based, Mach-Zenhder interferometer will be built and used near the ends of the 10 meter-long AWAKE plasma source to be able to make accurate relative density measurement between these two locations. This can then be used to infer the vapor density gradient along the AWAKE plasma source and also change it to the value desired for the plasma wakefield experiment. Here we describe the plan in detail and show preliminary results obtained using a prot...

  8. An accurate Rb density measurement method for a plasma wakefield accelerator experiment using a novel Rb reservoir

    Science.gov (United States)

    Öz, E.; Batsch, F.; Muggli, P.

    2016-09-01

    A method to accurately measure the density of Rb vapor is described. We plan on using this method for the Advanced Wakefield (AWAKE) (Assmann et al., 2014 [1]) project at CERN , which will be the world's first proton driven plasma wakefield experiment. The method is similar to the hook (Marlow, 1967 [2]) method and has been described in great detail in the work by Hill et al. (1986) [3]. In this method a cosine fit is applied to the interferogram to obtain a relative accuracy on the order of 1% for the vapor density-length product. A single-mode, fiber-based, Mach-Zenhder interferometer will be built and used near the ends of the 10 meter-long AWAKE plasma source to be able to make accurate relative density measurement between these two locations. This can then be used to infer the vapor density gradient along the AWAKE plasma source and also change it to the value desired for the plasma wakefield experiment. Here we describe the plan in detail and show preliminary results obtained using a prototype 8 cm long novel Rb vapor cell.

  9. Measuring Physical Inactivity: Do Current Measures Provide an Accurate View of “Sedentary” Video Game Time?

    Directory of Open Access Journals (Sweden)

    Simon Fullerton

    2014-01-01

    Full Text Available Background. Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Methods. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n=2026 were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Results. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children’s video game time. Conclusions. A substantial proportion of time that would usually be classified as “sedentary” may actually be spent participating in light to moderate physical activity.

  10. Accurate Measurement of Pasting Temperature by the Rapid Visco-Analyser: a Case Study Using Rice Flour

    Directory of Open Access Journals (Sweden)

    Jin-song BAO

    2008-03-01

    Full Text Available Pasting properties are among the most important characteristics of starch, determining its applications in food processing and other industries. Pasting temperature derived from the Rapid Visco-analyser (RVA (Newport Scientific, in most cases, is overestimated by the Thermocline for Windows software program. Here, two methods facilitating accurate measurement of pasting temperature by RVA were described. One is to change parameter setting to ‘screen’ the true point where the pasting viscosity begins to increase, the other is to manually record the time (T1 when the pasting viscosity begins to increase and calculate the pasting temperature with the formula of (45/3.8×(T1–1+50 for rice flour. The latter method gave a manually determined pasting temperature which was significantly correlated with the gelatinization temperature measured by differential scanning calorimetry.

  11. Minimal Clinically Important Difference of Patient Reported Outcome Measures of Lower Extremity Injuries in Orthopedics

    Science.gov (United States)

    Çelik, Derya; Çoban, Özge; Kılıçoğlu, Önder

    2017-01-01

    Purpose: MCID scores for outcome measures are frequently used evidence-based guides to gage meaningful changes. To conduct a systematic review of the quality and content of the the minimal clinically important difference (MCID) relating to 16 patient-rated outcome measures (PROM) used in lower extremity. Methods: We conducted a systematic literature review on articles reporting MCID in lower extremity outcome measures and orthopedics from January 1, 1980, to May 10, 2016. We evaluated MCID of the 16 patient reported outcome measures (PROM) which were Harris Hip Score (HHS), Oxford Hip Score (OHS), Hip Outcome Score (HOS), Hip Disability and Osteoarthritis Outcome Score (HOOS), The International Knee Documentation Committee Subjective Knee Form (IKDC), The Lysholm Scale, The Western Ontario Meniscal Evaluation Tool (WOMET), The Anterior Cruciate Ligament Quality of Life Questionnaire (ACL-QOL), The Lower Extremity Functional Scale (LEFS), The Western Ontario and Mcmaster Universities Index (WOMAC), Knee İnjury And Osteoarthritis Outcome Score (KOOS), Oxford Knee Score (OKS), Kujala Anterior Knee Pain Scale, The Victorian Institute of Sports Assessment Patellar Tendinosis (Jumper’s Knee) (VİSA-P), Tegner Activity Rating Scale, Marx Activity Rating Scale, Foot And Ankle Outcome Score (FAOS), The Foot Function Index (FFI), Foot And Ankle Ability Measure (FAAM), The Foot And Ankle Disability Index Score and Sports Module, Achill Tendon Total Rupture Score(ATRS), The Victorian İnstitute Of Sports Assesment Achilles Questionnaire(VİSA-A), American Orthopaedic Foot and Ankle Society (AOFAS). A search of the PubMed/MEDLINE, PEDro and Cochrane Cen¬tral Register of Controlled Trials and Web of Science databases from the date of inception to May 1, 2016 was conducted. The terms “minimal clinically important difference,” “minimal clinically important change”, “minimal clinically important improvement” “were combined with one of the PROM as mentioned above

  12. The mean prehospital machine; accurate prehospital non-invasive blood pressure measurement in the critically ill patient.

    Science.gov (United States)

    Muecke, Sandy; Bersten, Andrew; Plummer, John

    2010-06-01

    Non-invasive blood pressure recordings may be inaccurate in the critically ill patient and measurement difficulties are intensified in the prehospital setting. This may adversely impact upon outcomes for many critically ill patients, particularly those with traumatic brain injury and/or lengthy prehospital times. This study aimed to validate a non-invasive, oscillometric, ambulatory blood pressure measuring device, the Oscar 2, Model 222 (SunTech Medical, Morrisville, USA) during the ambulance transport of critically ill patients. We have previously shown that mean arterial blood pressures observed by Intensive Care Unit nurses from a patient monitor can be considered interchangeable with reference intra-arterial integrated mean pressures. In the current study, we compared non-invasive device mean pressures to intra-arterial pressures observed by retrieval nurses from the patient monitor, during the ambulance transportation of critically ill patients. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol requirements. Additionally, linear mixed effects analyses and Bland-Altman comparisons were undertaken. For 157 measurements recorded from 23 patients, when the Oscar 2 did not indicate a measurement was associated with a fault, the device fulfilled the AAMI protocol requirements, with a mean error of -1.1 mmHg (standard deviation 7.8 mmHg), 95% confidence intervals (linear mixed effects analysis) -2.9, 0.8; P = 0.26. Bland-Altman plots indicated uniform agreement across a wide range of blood pressures. Sixteen percent of recordings were associated with a patient, environment, or device generated fault. When the Oscar 2 does not indicate a fault has occurred, clinicians may be confident the mean pressure, within acceptable limits, is accurate, even during ambulance motion, administration of high doses of vasopressors and mechanical ventilation. The Oscar 2 appears to be an accurate and rugged out

  13. Accurate measurements of cross-plane thermal conductivity of thin films by dual-frequency time-domain thermoreflectance (TDTR).

    Science.gov (United States)

    Jiang, Puqing; Huang, Bin; Koh, Yee Kan

    2016-07-01

    Accurate measurements of the cross-plane thermal conductivity Λcross of a high-thermal-conductivity thin film on a low-thermal-conductivity (Λs) substrate (e.g., Λcross/Λs > 20) are challenging, due to the low thermal resistance of the thin film compared with that of the substrate. In principle, Λcross could be measured by time-domain thermoreflectance (TDTR), using a high modulation frequency fh and a large laser spot size. However, with one TDTR measurement at fh, the uncertainty of the TDTR measurement is usually high due to low sensitivity of TDTR signals to Λcross and high sensitivity to the thickness hAl of Al transducer deposited on the sample for TDTR measurements. We observe that in most TDTR measurements, the sensitivity to hAl only depends weakly on the modulation frequency f. Thus, we performed an additional TDTR measurement at a low modulation frequency f0, such that the sensitivity to hAl is comparable but the sensitivity to Λcross is near zero. We then analyze the ratio of the TDTR signals at fh to that at f0, and thus significantly improve the accuracy of our Λcross measurements. As a demonstration of the dual-frequency approach, we measured the cross-plane thermal conductivity of a 400-nm-thick nickel-iron alloy film and a 3-μm-thick Cu film, both with an accuracy of ∼10%. The dual-frequency TDTR approach is useful for future studies of thin films.

  14. Can endocranial volume be estimated accurately from external skull measurements in great-tailed grackles (Quiscalus mexicanus?

    Directory of Open Access Journals (Sweden)

    Corina J. Logan

    2015-06-01

    Full Text Available There is an increasing need to validate and collect data approximating brain size on individuals in the field to understand what evolutionary factors drive brain size variation within and across species. We investigated whether we could accurately estimate endocranial volume (a proxy for brain size, as measured by computerized tomography (CT scans, using external skull measurements and/or by filling skulls with beads and pouring them out into a graduated cylinder for male and female great-tailed grackles. We found that while females had higher correlations than males, estimations of endocranial volume from external skull measurements or beads did not tightly correlate with CT volumes. We found no accuracy in the ability of external skull measures to predict CT volumes because the prediction intervals for most data points overlapped extensively. We conclude that we are unable to detect individual differences in endocranial volume using external skull measurements. These results emphasize the importance of validating and explicitly quantifying the predictive accuracy of brain size proxies for each species and each sex.

  15. Manipulation of Samples at Extreme Temperatures for Fast in-situ Synchrotron Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Richard [Materials Development, Inc., Arlington Heights, IL (United States)

    2016-04-22

    An aerodynamic sample levitation system with laser beam heating was integrated with the APS beamlines 6 ID-D, 11 ID-C and 20 BM-B. The new capability enables in-situ measurements of structure and XANES at extreme temperatures (300-3500 °C) and in conditions that completely avoid contact with container surfaces. In addition to maintaining a high degree of sample purity, the use of aerodynamic levitation enables deep supercooling and greatly enhanced glass formation from a wide variety of melts and liquids. Development and integration of controlled extreme sample environments and new measurement techniques is an important aspect of beamline operations and user support. Processing and solidifying liquids is a critical value-adding step in manufacturing semiconductors, optical materials, metals and in the operation of many energy conversion devices. Understanding structural evolution is of fundamental importance in condensed materials, geology, and biology. The new capability provides unique possibilities for materials research and helps to develop and maintain a competitive materials manufacturing and energy utilization industry. Test samples were used to demonstrate key features of the capability including experiments on hot crystalline materials, liquids at temperatures from about 500 to 3500 °C. The use of controlled atmospheres using redox gas mixtures enabled in-situ changes in the oxidation states of cations in melts. Significant innovations in this work were: (i) Use of redox gas mixtures to adjust the oxidation state of cations in-situ (ii) Operation with a fully enclosed system suitable for work with nuclear fuel materials (iii) Making high quality high energy in-situ x-ray diffraction measurements (iv) Making high quality in-situ XANES measurements (v) Publishing high impact results (vi) Developing independent funding for the research on nuclear materials This SBIR project work led to a commercial instrument product for the niche market of processing and

  16. Measuring Transmittance in Rubidium Vapour Cells Using an Extremely Weak Coherent Field of Light

    Institute of Scientific and Technical Information of China (English)

    邓见辽; 黎永青; 王育竹

    2003-01-01

    The absorptive properties of the atomic transition in the Rb85 D2 (A) line (5S1/2-5Pa/2) at 780.0 nm are measured by using a continuous tunable diode laser and a CCD detector in Rb vapour cell under the condition of extremely weak incident intensity. When the intensity of incident light decreases from 420pW/cm2 to 0.03pW/cm2, the transmittance is found to be independent of the incident intensity within our experimental accuracy.

  17. Measurement of the extreme ankle range of motion required by female ballet dancers.

    Science.gov (United States)

    Russell, Jeffrey A; Kruse, David W; Nevill, Alan M; Koutedakis, Yiannis; Wyon, Matthew A

    2010-12-01

    Female ballet dancers require extreme ankle motion, especially plantar flexion, but research about measuring such motion is lacking. The purposes of this study were to determine in a sample of ballet dancers whether non-weight-bearing ankle range of motion is significantly different from the weight-bearing equivalent and whether inclinometric plantar flexion measurement is a suitable substitute for standard plantar flexion goniometry. Fifteen female ballet dancers (5 university, 5 vocational, and 5 professional dancers; age 21 ± 3.0 years) volunteered. Subjects received 5 assessments on 1 ankle: non-weight-bearing goniometry dorsiflexion (NDF) and plantar flexion (NPF), weight-bearing goniometry in the ballet positions demi-plié (WDF) and en pointe (WPF), and non-weight-bearing plantar flexion inclinometry (IPF). Mean NDF was significantly lower than WDF (17° ± 1.3° vs 30° ± 1.8°, P ballet proficiency. The authors conclude that assessment of extreme ankle motion in female ballet dancers is challenging, and goniometry and inclinometry appear to measure plantar flexion differently.

  18. Measurements and identifications of extreme ultraviolet spectra of highly-charged Sm and Er

    CERN Document Server

    Podpaly, Y A; Reader, J; Ralchenko, Yu

    2014-01-01

    We report spectroscopic measurements of highly charged samarium and erbium performed at the National Institute of Standards and Technology (NIST) Electron Beam Ion Trap (EBIT). These measurements are in the extreme ultraviolet (EUV) range, and span electron beam energies from 0.98 keV to 3.00 keV. We observed 71 lines from Kr-like Sm$^{26+}$ to Ni-like Sm$^{34+}$, connecting 83 energy levels, and 64 lines from Rb-like Er$^{32+}$ to Ni-like Er$^{40+}$, connecting 78 energy levels. Of these lines, 64 in Sm and 60 in Er are new. Line identifications are performed using collisional-radiative modeling of the EBIT plasma. All spectral lines are assigned individual uncertainties, most in the $\\sim$0.001 nm range. Energy levels are derived from the wavelength measurements.

  19. Accurate mass measurements of very short-lived nuclei. Prerequisites for high-accuracy investigations of superallowed {beta}-decays

    Energy Technology Data Exchange (ETDEWEB)

    Herfurth, F.; Kellerbauer, A.; Sauvan, E. [CERN, 1211 Geneva 23 (Switzerland); Ames, F.; Engels, O. [Sektion Physik, Ludwig-Maximilians-Universitaet Muenchen, 85748 Garching (Germany); Audi, G.; Lunney, D. [CSNSM-IN2P3-CNRS, 91405 Orsay Campus (France); Beck, D.; Blaum, K.; Kluge, H.J.; Scheidenberger, C.; Sikler, G.; Weber, C. [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Bollen, G.; Schwarz, S. [NSCL, Michigan State University, East Lansing MI 48824-1321 (United States); Moore, R.B. [Department of Physics, McGill University, Montreal (Quebec) H3A 2T8 (Canada); Oinonen, M. [Helsinki Institute of Physics, University of Helsinki, P.O. Box 9, 00014 Helsinki (Finland)

    2002-10-01

    Mass measurements of {sup 34}Ar, {sup 73-78}Kr, and {sup 74,76}Rb were performed with the Penning-trap mass spectrometer ISOLTRAP. Very accurate Q{sub EC}-values are needed for the investigations of the Ft-value of 0{sup +} {yields} 0{sup +} nuclear {beta}-decays used to test the standard model predictions for weak interactions. The necessary accuracy on the Q{sub EC}-value requires the mass of mother and daughter nuclei to be measured with {delta}m/m {<=} 3{sup .}10 {sup -8}. For most of the measured nuclides presented here this has been reached. The {sup 34}Ar mass has been measured with a relative accuracy of 1.1 .10{sup -8}. The Q {sub EC}-value of the {sup 34}Ar 0 {sup +} {yields} 0 {sup +} decay can now be determined with an uncertainty of about 0.01%. Furthermore, {sup 74}Rb is the shortest-lived nuclide ever investigated in a Penning trap. (orig.)

  20. The influence of subject and test design on dynamometric measurements of extremity muscles.

    Science.gov (United States)

    Keating, J L; Matyas, T A

    1996-08-01

    In the context of broader discussions of clinical dynamometry, earlier reviews have raised concerns about the potential effects of variations in subject factors and test procedures on measurements. None, however, have dealt exclusively with these effects. We therefore reviewed more than 200 articles to evaluate in detail the effects of variations in subject factors and test procedures on measurements. Factors relating to subjects that affected measurements were age, gender, weight, athletic background, disability, and limb dominance. Test conditions that led to variations in measurements were range of movement in which values were obtained, type of contraction or movement (concentric, eccentric, isokinetic, isometric, isotonic), pretest procedures (warm-up and gravity-correction procedures, starting position, stabilization, axes alignment, lever arm length, preload, damp/ramp settings), test conditions (speed, test sequence, rest intervals, feedback), and type of data analysis (the data selected and how they are manipulated). In the majority of the publications, the authors failed to provide sufficient detail for accurate replication of test procedures or for comparison with other studies. We advocate that the factors identified in this review be included whenever measurements obtained with a dynamometer are reported. Effective development of normative data, formation of ratios, comparison of measurements across studies, and relating measurements with other performance criteria (eg, measurements of functional performance) all require descriptions of variables relating to subjects and testing. Similarly, meaningful use of these measurements in clinical practice requires consideration and documentation of these variables.

  1. Accurate Measurement of Pasting Temperature by the Rapid Visco-Analyser:a Case Study Using Rice Flour

    Institute of Scientific and Technical Information of China (English)

    BAO Jin-song

    2008-01-01

    Pasting properties are among the most important characteristics of starch,determining its applications in food processing and other industries.Pasting temperature derived from the Rapid Visco-analyser(RVA)(Newport Scientific),in most cases,is overestimated by the Thermocline for Windows software program.Here,two methods facilitating accurate where the pasting viscosity begins to increase,the other is to manually record the time(T1)when the pasting viscosity begins to increase and calculate the pasting temperature with the formula of(45/3.8)×(T1-1)+50 for rice flour.The latter method gave a manually determined pasting temperature which was significantly correlated with the gelatinization temperature measured by differential scanning calorimetry.

  2. Hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products

    Science.gov (United States)

    Cen, Haiyan

    Hyperspectral imaging-based spatially-resolved technique is promising for determining the optical properties and quality attributes of horticultural and food products. However, considerable challenges still exist for accurate determination of spectral absorption and scattering properties from intact horticultural products. The objective of this research was, therefore, to develop and optimize hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products. Monte Carlo simulations and experiments for model samples of known optical properties were performed to optimize the inverse algorithm of a single-layer diffusion model and the optical designs, for extracting the absorption (micro a) and reduced scattering (micros') coefficients from spatially-resolved reflectance profiles. The logarithm and integral data transformation and the relative weighting methods were found to greatly improve the parameter estimation accuracy with the relative errors of 10.4%, 10.7%, and 11.4% for micro a, and 6.6%, 7.0%, and 7.1% for micros', respectively. More accurate measurements of optical properties were obtained when the light beam was of Gaussian type with the diameter of less than 1 mm, and the minimum and maximum source-detector distances were 1.5 mm and 10--20 transport mean free paths, respectively. An optical property measuring prototype was built, based on the optimization results, and evaluated for automatic measurement of absorption and reduced scattering coefficients for the wavelengths of 500--1,000 nm. The instrument was used to measure the optical properties, and assess quality/maturity, of 500 'Redstar' peaches and 1039 'Golden Delicious' (GD) and 1040 'Delicious' (RD) apples. A separate study was also conducted on confocal laser scanning and scanning electron microscopic image analysis and compression test of fruit tissue specimens to measure the structural and mechanical properties of 'Golden

  3. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS technique

    Directory of Open Access Journals (Sweden)

    H. Chen

    2013-04-01

    Full Text Available Accurate measurements of carbon monoxide (CO in humid air have been made using the cavity ring-down spectroscopy (CRDS technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near-infrared region (~1.57 μm after removing interferences from adjacent carbon dioxide (CO2 and water vapor (H2O absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360–390 ppm and for reported H2O mole fractions between 0–4%. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately −0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of −0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs improved spectroscopic model functions for CO2, H2O, and CO to fit the raw spectral data (available since the beginning of 2012 indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  4. Necessary Conditions for Accurate, Transient Hot-Wire Measurements of the Apparent Thermal Conductivity of Nanofluids are Seldom Satisfied

    Science.gov (United States)

    Antoniadis, Konstantinos D.; Tertsinidou, Georgia J.; Assael, Marc J.; Wakeham, William A.

    2016-08-01

    The paper considers the conditions that are necessary to secure accurate measurement of the apparent thermal conductivity of two-phase systems comprising nanoscale particles of one material suspended in a fluid phase of a different material. It is shown that instruments operating according to the transient hot-wire technique can, indeed, produce excellent measurements when a finite element method (FEM) is employed to describe the instrument for the exact geometry of the hot wire. Furthermore, it is shown that an approximate analytic solution can be employed with equal success, over the time range of 0.1 s to 1 s, provided that (a) two wires are employed, so that end effects are canceled, (b) each wire is very thin, less than 30 \\upmu m diameter, so that the line source model and the corresponding corrections are valid, (c) low values of the temperature rise, less than 4 K, are employed in order to minimize the effect of convection on the heat transfer in the time of measurement of 1 s, and (d) insulated wires are employed for measurements in electrically conducting or polar liquids to avoid current leakage or other electrical distortions. According to these criteria, a transient hot-wire instrument has been designed, constructed, and employed for the measurement of the enhancement of the thermal conductivity of water when TiO2 or multi-wall carbon nanotubes (MWCNT) are added. These new results, together with a critical evaluation of other measurements, demonstrate the importance of proper implementation of the technique.

  5. Forecasting Financial Extremes: A Network Degree Measure of Super-Exponential Growth.

    Directory of Open Access Journals (Sweden)

    Wanfeng Yan

    Full Text Available Investors in stock market are usually greedy during bull markets and scared during bear markets. The greed or fear spreads across investors quickly. This is known as the herding effect, and often leads to a fast movement of stock prices. During such market regimes, stock prices change at a super-exponential rate and are normally followed by a trend reversal that corrects the previous overreaction. In this paper, we construct an indicator to measure the magnitude of the super-exponential growth of stock prices, by measuring the degree of the price network, generated from the price time series. Twelve major international stock indices have been investigated. Error diagram tests show that this new indicator has strong predictive power for financial extremes, both peaks and troughs. By varying the parameters used to construct the error diagram, we show the predictive power is very robust. The new indicator has a better performance than the LPPL pattern recognition indicator.

  6. Forecasting Financial Extremes: A Network Degree Measure of Super-Exponential Growth.

    Science.gov (United States)

    Yan, Wanfeng; van Tuyll van Serooskerken, Edgar

    2015-01-01

    Investors in stock market are usually greedy during bull markets and scared during bear markets. The greed or fear spreads across investors quickly. This is known as the herding effect, and often leads to a fast movement of stock prices. During such market regimes, stock prices change at a super-exponential rate and are normally followed by a trend reversal that corrects the previous overreaction. In this paper, we construct an indicator to measure the magnitude of the super-exponential growth of stock prices, by measuring the degree of the price network, generated from the price time series. Twelve major international stock indices have been investigated. Error diagram tests show that this new indicator has strong predictive power for financial extremes, both peaks and troughs. By varying the parameters used to construct the error diagram, we show the predictive power is very robust. The new indicator has a better performance than the LPPL pattern recognition indicator.

  7. Children’s Personal Exposure Measurements to Extremely Low Frequency Magnetic Fields in Italy

    Directory of Open Access Journals (Sweden)

    Ilaria Liorni

    2016-05-01

    Full Text Available Extremely low frequency magnetic fields (ELF-MFs exposure is still a topic of concern due to their possible impact on children’s health. Although epidemiological studies claimed an evidence of a possible association between ELF-MF above 0.4 μT and childhood leukemia, biological mechanisms able to support a causal relationship between ELF-MF and this disease were not found yet. To provide further knowledge about children’s ELF-MF exposure correlated to children’s daily activities, a measurement study was conducted in Milan (Italy. Eighty-six children were recruited, 52 of whom were specifically chosen with respect to the distance to power lines and built-in transformers to oversample potentially highly exposed children. Personal and bedroom measurements were performed for each child in two different seasons. The major outcomes of this study are: (1 median values over 24-h personal and bedroom measurements were <3 μT established by the Italian law as the quality target; (2 geometric mean values over 24-h bedroom measurements were mostly <0.4 μT; (3 seasonal variations did not significantly influence personal and bedroom measurements; (4 the highest average MF levels were mostly found at home during the day and outdoors; (5 no significant differences were found in the median and geometric mean values between personal and bedroom measurements, but were found in the arithmetic mean.

  8. Children's Personal Exposure Measurements to Extremely Low Frequency Magnetic Fields in Italy.

    Science.gov (United States)

    Liorni, Ilaria; Parazzini, Marta; Struchen, Benjamin; Fiocchi, Serena; Röösli, Martin; Ravazzani, Paolo

    2016-05-31

    Extremely low frequency magnetic fields (ELF-MFs) exposure is still a topic of concern due to their possible impact on children's health. Although epidemiological studies claimed an evidence of a possible association between ELF-MF above 0.4 μT and childhood leukemia, biological mechanisms able to support a causal relationship between ELF-MF and this disease were not found yet. To provide further knowledge about children's ELF-MF exposure correlated to children's daily activities, a measurement study was conducted in Milan (Italy). Eighty-six children were recruited, 52 of whom were specifically chosen with respect to the distance to power lines and built-in transformers to oversample potentially highly exposed children. Personal and bedroom measurements were performed for each child in two different seasons. The major outcomes of this study are: (1) median values over 24-h personal and bedroom measurements were values over 24-h bedroom measurements were mostly personal and bedroom measurements; (4) the highest average MF levels were mostly found at home during the day and outdoors; (5) no significant differences were found in the median and geometric mean values between personal and bedroom measurements, but were found in the arithmetic mean.

  9. Children’s Personal Exposure Measurements to Extremely Low Frequency Magnetic Fields in Italy

    Science.gov (United States)

    Liorni, Ilaria; Parazzini, Marta; Struchen, Benjamin; Fiocchi, Serena; Röösli, Martin; Ravazzani, Paolo

    2016-01-01

    Extremely low frequency magnetic fields (ELF-MFs) exposure is still a topic of concern due to their possible impact on children’s health. Although epidemiological studies claimed an evidence of a possible association between ELF-MF above 0.4 μT and childhood leukemia, biological mechanisms able to support a causal relationship between ELF-MF and this disease were not found yet. To provide further knowledge about children’s ELF-MF exposure correlated to children’s daily activities, a measurement study was conducted in Milan (Italy). Eighty-six children were recruited, 52 of whom were specifically chosen with respect to the distance to power lines and built-in transformers to oversample potentially highly exposed children. Personal and bedroom measurements were performed for each child in two different seasons. The major outcomes of this study are: (1) median values over 24-h personal and bedroom measurements were <3 μT established by the Italian law as the quality target; (2) geometric mean values over 24-h bedroom measurements were mostly <0.4 μT; (3) seasonal variations did not significantly influence personal and bedroom measurements; (4) the highest average MF levels were mostly found at home during the day and outdoors; (5) no significant differences were found in the median and geometric mean values between personal and bedroom measurements, but were found in the arithmetic mean. PMID:27258295

  10. Patient Reported Outcomes Measurement Information System (PROMIS) in the upper extremity: the future of outcomes reporting?

    Science.gov (United States)

    Makhni, Eric C; Meadows, Molly; Hamamoto, Jason T; Higgins, John D; Romeo, Anthony A; Verma, Nikhil N

    2017-02-01

    Patient reported outcomes (PROs) serve an integral role in clinical research by helping to determine the impact of clinical care as experienced by the patient. With recent initiatives in health care policy and pay for performance, outcome reporting is now recognized as a policy-driven requirement in addition to a clinical research tool. For outcome measures to satisfy these regulatory requirements and provide value in understanding disease outcomes, they must be responsive and efficient. Recent research has uncovered certain concerns regarding traditional PROs in patients with upper extremity disability and injury. These include lack of consensus regarding selection of PROs for a given diagnoses, inconsistent techniques of administration of the same PROs, and the administrative burden to patients and providers of completing these forms. To address these limitations, emphasis has been placed on streamlining the outcomes reporting process, and, as a result, the National Institutes of Health (NIH) created the Patient Reported Outcomes Measurement Information System (PROMIS). PROMIS forms were created to comprehensively and efficiently measure outcomes across multiple disease states, including orthopedics. These tools exist in computer adaptive testing and short forms with the intention of more efficiently measuring outcomes compared with legacy PROs. The goals of this review are to highlight the main components of PROMIS reporting tools and identify recent use of the scores in the upper extremity literature. The review will also highlight the research and health policy potentials and limitations of implementing PROMIS into everyday orthopedic practice. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.

    2001-01-01

    Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

  12. Visual acuity measured with a smartphone app is more accurate than Snellen testing by emergency department providers.

    Science.gov (United States)

    Pathipati, Akhilesh S; Wood, Edward H; Lam, Carson K; Sáles, Christopher S; Moshfeghi, Darius M

    2016-06-01

    To assess the accuracy of best-corrected visual acuity (BCVA) measured by non-ophthalmic emergency department (ED) staff with a standard Snellen chart versus an automated application (app) on a handheld smartphone (Paxos Checkup, San Francisco, CA, USA). The study included 128 subjects who presented to the Stanford Hospital ED for whom the ED requested an ophthalmology consultation. We conducted the study in two phases. During phase 1 of the study, ED staff tested patient BCVA using a standard Snellen test at 20 feet. During phase 2 of the study, ED staff tested patient near BCVA using the app. During both phases, ophthalmologists measured BCVA with a Rosenbaum near chart, which was treated as the gold standard. ED BCVA measurements were benchmarked prospectively against ophthalmologists' measurements and converted to logMAR. ED logMAR BCVA was 0.21 ± 0.35 (approximately 2 Snellen lines difference ± 3 Snellen lines) higher than that of ophthalmologists when ED staff used a Snellen chart (p = .0.00003). ED BCVA was 0.06 ± 0.40 (less than 1 Snellen line ± 4 Snellen lines) higher when ED staff used the app (p = 0.246). Inter-observer difference was therefore smaller by more than 1 line (0.15 logMAR) with the app (p = 0.046). BCVA measured by non-ophthalmic ED staff with an app was more accurate than with a Snellen chart. Automated apps may provide a means to standardize and improve the efficiency of ED ophthalmologic care.

  13. Assimilation of Sentinel-1 estimates of Precipitable Water Vapor (PWV) into a Numerical Weather Model for a more accurate forecast of extreme weather events

    Science.gov (United States)

    Mateus, Pedro; Nico, Giovanni; Catalao, Joao

    2017-04-01

    In the last two decades, SAR interferometry has been used to obtain maps of Precipitable Water Vapor (PWV).This maps are characterized by their high spatial resolution when compared to the currently available PWV measurements (e.g. GNSS, radiometers or radiosondes). Several previous works have shown that assimilating PWV values, mainly derived from GNSS observations, into Numerical Weather Models (NWMs) can significantly improve rainfall predictions.It is noteworthy that the PWV-derived from GNSS observations have a high temporal resolution but a low spatialone. In addition, there are many regions without any GNSS stations, where temporal and spatial distribution of PWV areonly available through satellite measurements. The first attempt to assimilate InSAR-derived maps of PWV (InSAR-PWV) into a NWM was made by Pichelli et al. [1].They used InSAR-PWV maps obtained from ENVISAT-ASAR images and the mesoscale weather prediction model MM5 over the city of Rome, Italy. The statistical indices show that the InSAR-PWVdata assimilation improves the forecast of weak to moderateprecipitation (model over the city of Lisbon, Portugal, during a light rain event not forecast by the model.Results showed that after data assimilation, there is a bias correction of the PWV field and an improvement in the forecast of the weakto moderate rainfall up to 9 h after the assimilation time. We used, for the first time, the Weather Research and Forecast Data Assimilation (WRFDA) model, at micro-scale resolutions (3 km), over the Iberian Peninsula (focusing on the southern region of Spain) and during a convective cell associated with a local heavy rainfall event, to study the impact of assimilation PWV maps obtained from SAR interferometric phase calculated using images acquired by the Sentinel-1 satellite. It's worth noting that, in this case, the model without assimilation PWV maps fails to reproduce the amount and the region of heavy rainfall. The assimilation of InSAR-PWV maps with high

  14. The Cambridge Face Tracker: Accurate, Low Cost Measurement of Head Posture Using Computer Vision and Face Recognition Software

    Science.gov (United States)

    Thomas, Peter B. M.; Baltrušaitis, Tadas; Robinson, Peter; Vivian, Anthony J.

    2016-01-01

    Purpose We validate a video-based method of head posture measurement. Methods The Cambridge Face Tracker uses neural networks (constrained local neural fields) to recognize facial features in video. The relative position of these facial features is used to calculate head posture. First, we assess the accuracy of this approach against videos in three research databases where each frame is tagged with a precisely measured head posture. Second, we compare our method to a commercially available mechanical device, the Cervical Range of Motion device: four subjects each adopted 43 distinct head postures that were measured using both methods. Results The Cambridge Face Tracker achieved confident facial recognition in 92% of the approximately 38,000 frames of video from the three databases. The respective mean error in absolute head posture was 3.34°, 3.86°, and 2.81°, with a median error of 1.97°, 2.16°, and 1.96°. The accuracy decreased with more extreme head posture. Comparing The Cambridge Face Tracker to the Cervical Range of Motion Device gave correlation coefficients of 0.99 (P < 0.0001), 0.96 (P < 0.0001), and 0.99 (P < 0.0001) for yaw, pitch, and roll, respectively. Conclusions The Cambridge Face Tracker performs well under real-world conditions and within the range of normally-encountered head posture. It allows useful quantification of head posture in real time or from precaptured video. Its performance is similar to that of a clinically validated mechanical device. It has significant advantages over other approaches in that subjects do not need to wear any apparatus, and it requires only low cost, easy-to-setup consumer electronics. Translational Relevance Noncontact assessment of head posture allows more complete clinical assessment of patients, and could benefit surgical planning in future. PMID:27730008

  15. The Cambridge Face Tracker: Accurate, Low Cost Measurement of Head Posture Using Computer Vision and Face Recognition Software.

    Science.gov (United States)

    Thomas, Peter B M; Baltrušaitis, Tadas; Robinson, Peter; Vivian, Anthony J

    2016-09-01

    We validate a video-based method of head posture measurement. The Cambridge Face Tracker uses neural networks (constrained local neural fields) to recognize facial features in video. The relative position of these facial features is used to calculate head posture. First, we assess the accuracy of this approach against videos in three research databases where each frame is tagged with a precisely measured head posture. Second, we compare our method to a commercially available mechanical device, the Cervical Range of Motion device: four subjects each adopted 43 distinct head postures that were measured using both methods. The Cambridge Face Tracker achieved confident facial recognition in 92% of the approximately 38,000 frames of video from the three databases. The respective mean error in absolute head posture was 3.34°, 3.86°, and 2.81°, with a median error of 1.97°, 2.16°, and 1.96°. The accuracy decreased with more extreme head posture. Comparing The Cambridge Face Tracker to the Cervical Range of Motion Device gave correlation coefficients of 0.99 (P Cambridge Face Tracker performs well under real-world conditions and within the range of normally-encountered head posture. It allows useful quantification of head posture in real time or from precaptured video. Its performance is similar to that of a clinically validated mechanical device. It has significant advantages over other approaches in that subjects do not need to wear any apparatus, and it requires only low cost, easy-to-setup consumer electronics. Noncontact assessment of head posture allows more complete clinical assessment of patients, and could benefit surgical planning in future.

  16. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang; Yizheng Zhu

    2005-04-01

    This report summarizes technical progress October 2004-March 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report.

  17. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Anbo Wang

    2007-03-31

    This report summarizes technical progress October 2006 - March 2007 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. During the second phase, an alternative high temperature sensing system based on Fabry-Perot interferometry was developed that offers a number of advantages over the BPDI solution. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. The sapphire wafer-based interferometric sensing system that was installed at TECO's Polk Power Station remained in operation for seven months. Our efforts have been focused on monitoring and analyzing the real-time data collected, and preparing for a second field test.

  18. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2003-04-01

    This report summarizes technical progress over the first six months of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on analyzing and testing factors that impact performance degradation of the initially designed sensor prototype, including sensing element movement within the sensing probe and optical signal quality degradation. Based these results, a new version of the sensing system was designed by combining the sapphire disk sensing element and the single crystal zirconia right angle light reflector into one novel single crystal sapphire right angle prism. The new sensor prototype was tested up to 1650 C.

  19. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2003-11-01

    This report summarizes technical progress over the second six month period of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on evaluating corrosion effects in single crystal sapphire at temperatures up to 1400 C, and designing the sensor mechanical packaging with input from Wabash River Power Plant. Upcoming meetings will establish details for the gasifier field test.

  20. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang

    2004-04-01

    This report summarizes technical progress over the third six month period of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on sensor probe design and machining, sensor electronics design, software algorithm design, sensor field installation procedures, and sensor remote data access and control. Field testing will begin in the next several weeks.

  1. Accurate measurements of {sup 129}I concentration by isotope dilution using MC-ICPMS for half-life determination

    Energy Technology Data Exchange (ETDEWEB)

    Isnard, Helene; Nonell, Anthony; Marie, Mylene [Commissariat a l' Energie Atomique et aux Energies alternatives (CEA), Gif Sur Yvette (France). DEN, DPC, SEARS, LANIE; Chartier, Frederic [Commissariat a l' Energie Atomique et aux Energies alternatives (CEA), Gif Sur Yvette (France). DEN, DPC

    2016-05-01

    Determining the {sup 129}I concentration, a long-lived radionuclide present in spent nuclear fuel, is a major issue for nuclear waste disposal purpose. {sup 129}I also has to be measured in numerous environmental, nuclear and biological samples. To be able to accurately determine the {sup 129}I concentration, an analytical method based on the use of a multicollector-inductively coupled plasma mass spectrometer (MC-ICPMS) combined with an isotope dilution technique using an {sup 127}I spike, was developed. First, the influence of different media (HNO{sub 3}, NaOH and TMAH) on natural {sup 127}I signal intensity and stability and on memory effects was studied. Then an analytical procedure was developed by taking into account the correction of blanks and interferences. Tellurium was chosen for instrumental mass bias correction, as no certified standards with suitable {sup 127}I/{sup 129}I ratio are available. Finally, the results, reproducibility and uncertainties obtained for the {sup 129}I concentration determined by isotope dilution with a {sup 127}I spike are presented and discussed. The final expanded relative uncertainty obtained for the iodine-129 concentration was lower than 0.7% (k = 1). This precise {sup 129}I determination in association with further activity measurements of this nuclide on the same sample will render it possible to determine a new value of the {sup 129}I half-life with a reduced uncertainty (0.76%, k = 1).

  2. Optimally accurate thermal-wave cavity photopyroelectric measurements of pressure-dependent thermophysical properties of air: theory and experiments.

    Science.gov (United States)

    Kwan, Chi-Hang; Matvienko, Anna; Mandelis, Andreas

    2007-10-01

    An experimental technique for the measurement of thermal properties of air at low pressures using a photopyroelectric (PPE) thermal-wave cavity (TWC) was developed. In addition, two theoretical approaches, a conventional one-dimensional thermal-wave model and a three-dimensional theory based on the Hankel integral, were applied to interpret the thermal-wave field in the thermal-wave cavity. The importance of radiation heat transfer mechanisms in a TWC was also investigated. Radiation components were added to the purely conductive model by linearizing the radiation heat transfer component at the cavity boundary. The experimental results indicate that the three-dimensional model is necessary to describe the PPE signal, especially at low frequencies where thermal diffusion length is large and sideways propagation of the thermal-wave field becomes significant. Radiation is found to be the dominant contributor of the PPE signal at high frequencies and large cavity lengths, where heat conduction across the TWC length is relatively weak. The three-dimensional theory and the Downhill Simplex algorithm were used to fit the experimental data and extract the thermal diffusivity of air and the heat transfer coefficient in a wide range of pressures from 760 to 2.6 Torr. It was shown that judicious adjustments of cavity length and computational best fits to frequency-scanned data using three-dimensional photopyroelectric theory lead to optimally accurate value measurements of thermal diffusivity and heat transfer coefficient at various pressures.

  3. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Anbo Wang

    2007-03-31

    This report summarizes technical progress October 2006 - March 2007 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. During the second phase, an alternative high temperature sensing system based on Fabry-Perot interferometry was developed that offers a number of advantages over the BPDI solution. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. The sapphire wafer-based interferometric sensing system that was installed at TECO's Polk Power Station remained in operation for seven months. Our efforts have been focused on monitoring and analyzing the real-time data collected, and preparing for a second field test.

  4. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang; Yizheng Zhu

    2005-04-01

    This report summarizes technical progress October 2004-March 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report.

  5. An accurate measurement of the baryonic Tully-Fisher relation with heavily gas-dominated ALFALFA galaxies

    CERN Document Server

    Papastergis, E; van der Hulst, J M

    2016-01-01

    We use a sample of 97 galaxies selected from the ALFALFA 21cm survey to make an accurate measurement of the baryonic Tully-Fisher relation (BTFR). These galaxies are specifically selected to be heavily gas-dominated (Mgas/M* >~ 2.7) and to be oriented edge-on. The former property ensures that the error on the galactic baryonic mass is small, despite the large systematic uncertainty involved in galactic stellar mass estimates. The latter property means that rotational velocities can be derived directly from the width of the 21cm emission line, without any need for inclination corrections. The resulting linewidth-based BTFR has a slope of alpha = 3.58 +- 0.11, a value that is in agreement with previous literature results. The relation is remarkably tight, with almost all galaxies being located within a perpendicular distance of +- 0.1 dex from the best fit line. The low observational error budget for our sample allows us to establish that, despite its tightness, the measured linewidth-based BTFR has some small ...

  6. Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems.

    Science.gov (United States)

    de Vries, W H K; Veeger, H E J; Cutti, A G; Baten, C; van der Helm, F C T

    2010-07-20

    Inertial Magnetic Measurement Systems (IMMS) are becoming increasingly popular by allowing for measurements outside the motion laboratory. The latest models enable long term, accurate measurement of segment motion in terms of joint angles, if initial segment orientations can accurately be determined. The standard procedure for definition of segmental orientation is based on the measurement of positions of bony landmarks (BLM). However, IMMS do not deliver position information, so an alternative method to establish IMMS based, anatomically understandable segment orientations is proposed. For five subjects, IMMS recordings were collected in a standard anatomical position for definition of static axes, and during a series of standardized motions for the estimation of kinematic axes of rotation. For all axes, the intra- and inter-individual dispersion was estimated. Subsequently, local coordinate systems (LCS) were constructed on the basis of the combination of IMMS axes with the lowest dispersion and compared with BLM based LCS. The repeatability of the method appeared to be high; for every segment at least two axes could be determined with a dispersion of at most 3.8 degrees. Comparison of IMMS based with BLM based LCS yielded compatible results for the thorax, but less compatible results for the humerus, forearm and hand, where differences in orientation rose to 17.2 degrees. Although different from the 'gold standard' BLM based LCS, IMMS based LCS can be constructed repeatable, enabling the estimation of segment orientations outside the laboratory. A procedure for the definition of local reference frames using IMMS is proposed. 2010 Elsevier Ltd. All rights reserved.

  7. In situ observation and measurement of composites subjected to extremely high temperature

    Science.gov (United States)

    Fang, Xufei; Yu, Helong; Zhang, Guobing; Su, Hengqiang; Tang, Hongxiang; Feng, Xue

    2014-03-01

    In this work, we develop an instrument to study the ablation and oxidation process of materials such as C/SiC (carbon fiber reinforced silicon carbide composites) and ultra-high temperature ceramic in extremely high temperature environment. The instrument is integrated with high speed cameras with filtering lens, infrared thermometers and water vapor generator for image capture, temperature measurement, and humid atmosphere, respectively. The ablation process and thermal shock as well as the temperature on both sides of the specimen can be in situ monitored. The results show clearly the dynamic ablation and liquid oxide flowing. In addition, we develop an algorithm for the post-processing of the captured images to obtain the deformation of the specimens, in order to better understand the behavior of the specimen subjected to high temperature.

  8. Space charge dosimeters for extremely low power measurements of radiation in shipping containers

    Science.gov (United States)

    Britton, Jr.; Charles L.; Buckner, Mark A.; Hanson, Gregory R.; Bryan, William L.

    2011-04-26

    Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

  9. Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema

    NARCIS (Netherlands)

    Meijer, R.S.; Rietman, J.S.; Geertzen, J.H.B.; Bosmans, J.C.; Dijkstra, P.U.

    2004-01-01

    We investigated a method of indirect volume measurement that utilized surface measurements and a simplified formula derived from the formula for a frustum (Sitzia's method) to determine limb volumes in patients with breast cancer-related lymphedema of the upper extremity. Repeated measurements of up

  10. Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema

    NARCIS (Netherlands)

    Meijer, R.S.; Rietman, J.S.; Geertzen, J.H.B.; Bosmans, J.C.; Dijkstra, P.U.

    We investigated a method of indirect volume measurement that utilized surface measurements and a simplified formula derived from the formula for a frustum (Sitzia's method) to determine limb volumes in patients with breast cancer-related lymphedema of the upper extremity. Repeated measurements of

  11. An accurate measurement of the baryonic Tully-Fisher relation with heavily gas-dominated ALFALFA galaxies

    Science.gov (United States)

    Papastergis, E.; Adams, E. A. K.; van der Hulst, J. M.

    2016-09-01

    We use a sample of 97 galaxies selected from the Arecibo legacy fast ALFA (ALFALFA) 21 cm survey to make an accurate measurement of the baryonic Tully-Fisher relation (BTFR). These galaxies are specifically selected to be heavily gas-dominated (Mgas/M∗ ≳ 2.7) and to be oriented edge-on. The former property ensures that the error on the galactic baryonic mass is small, despite the large systematic uncertainty involved in galactic stellar mass estimates. The latter property means that rotational velocities can be derived directly from the width of the 21 cm emission line, without any need for inclination corrections. We measure a slope for the linewidth-based BTFR of α = 3.75 ± 0.11, a value that is somewhat steeper than (but in broad agreement with) previous literature results. The relation is remarkably tight, with almost all galaxies being located within a perpendicular distance of ± 0.1 dex from the best fit line. The low observational error budget for our sample enables us to establish that, despite its tightness, the measured linewidth-based BTFR has some small (i.e., non-zero) intrinsic scatter. We furthermore find a systematic difference in the BTFR of galaxies with "double-horned" 21 cm line profiles - suggestive of flat outer galactic rotation curves - and those with "peaked" profiles - suggestive of rising rotation curves. When we restrict our sample of galaxies to objects in the former category, we measure a slightly steeper slope of α = 4.13 ± 0.15. Overall, the high-accuracy measurement of the BTFR presented in this article is intended as a reliable observational benchmark against which to test theoretical expectations. Here we consider a representative set of semi-analytic models and hydrodynamic simulations in the lambda cold dark matter (ΛCDM) context, as well as modified Newtonian dynamics (MOND). In the near future, interferometric follow-up observations of several sample members will enable us to further refine the BTFR measurement, and

  12. High-precision topography measurement through accurate in-focus plane detection with hybrid digital holographic microscope and white light interferometer module.

    Science.gov (United States)

    Liżewski, Kamil; Tomczewski, Sławomir; Kozacki, Tomasz; Kostencka, Julianna

    2014-04-10

    High-precision topography measurement of micro-objects using interferometric and holographic techniques can be realized provided that the in-focus plane of an imaging system is very accurately determined. Therefore, in this paper we propose an accurate technique for in-focus plane determination, which is based on coherent and incoherent light. The proposed method consists of two major steps. First, a calibration of the imaging system with an amplitude object is performed with a common autofocusing method using coherent illumination, which allows for accurate localization of the in-focus plane position. In the second step, the position of the detected in-focus plane with respect to the imaging system is measured with white light interferometry. The obtained distance is used to accurately adjust a sample with the precision required for the measurement. The experimental validation of the proposed method is given for measurement of high-numerical-aperture microlenses with subwavelength accuracy.

  13. SU-F-BRF-13: Investigating the Feasibility of Accurate Dose Measurement in a Deforming Radiochromic Dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Juang, T [Medical Physics Graduate Program, Duke University Medical Center, Durham, NC (United States); Adamovics, J [Rider University, Skillman, NJ (United States); Oldham, M [Duke University Medical Center, Durham, NC (United States)

    2014-06-15

    Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, high resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately

  14. Extremely low frequency magnetic field measurements in buildings with transformer stations in Switzerland.

    Science.gov (United States)

    Röösli, Martin; Jenni, Daniela; Kheifets, Leeka; Mezei, Gabor

    2011-08-15

    The aim of this study was to evaluate an exposure assessment method that classifies apartments in three exposure categories of extremely low frequency magnetic fields (ELF-MF) based on the location of the apartment relative to the transformer room. We completed measurements in 39 apartments in 18 buildings. In each room of the apartments ELF-MF was concurrently measured with 5 to 6 EMDEX II meters for 10 min. Measured arithmetic mean ELF-MF was 0.59 μT in 8 apartments that were fully adjacent to a transformer room, either directly above the transformer or touching the transformer room wall-to-wall. In apartments that only partly touched the transformer room at corners or edges, average ELF-MF level was 0.14 μT. Average exposure in the remaining apartments was 0.10 μT. Kappa coefficient for exposure classification was 0.64 (95%-CI: 0.45-0.82) if only fully adjacent apartments were considered as highly exposed (>0.4 μT). We found a distinct ELF-MF exposure gradient in buildings with transformer. Exposure classification based on the location of the apartment relative to the transformer room appears feasible. Such an approach considerably reduces effort for exposure assessment and may be used to eliminate selection bias in future epidemiologic studies.

  15. Measurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic concentration of environmental tritium samples.

    Science.gov (United States)

    Wassenaar, L I; Kumar, B; Douence, C; Belachew, D L; Aggarwal, P K

    2016-02-15

    Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry. Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectrometry, along with (2) H-enriched laboratory calibration standards and appropriate analysis templates, allows for low-cost, fast, and accurate determinations of water samples having δ(2) HVSMOW-SLAP values up to at least 57,000 ‰ (~9000 ppm) at a processing rate of 60 samples per day. As one practical application, extremely (2) H-enriched samples were measured by laser spectrometry and compared to the traditional (3) H Spike-Proxy method in order to determine tritium enrichment factors in the batch electrolysis of environmental waters. Highly (2) H-enriched samples were taken from different sets of electrolytically concentrated standards and low-level (tritium samples, and all cases returned accurate and precise initial low-level (3) H results. The ability to quickly and accurately measure extremely (2) H-enriched waters by laser spectrometry will facilitate the use of deuterium as a tracer in numerous environmental and other applications. For low-level tritium operations, this new analytical ability facilitated a 10-20 % increase in sample productivity through the elimination of spike standards and gravimetrics, and provides immediate feedback on electrolytic enrichment cell performance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. An accurate method to measure alpha-emitting natural radionuclides in atmospheric filters: Application in two NORM industries

    Science.gov (United States)

    Lozano, R. L.; Bolívar, J. P.; San Miguel, E. G.; García-Tenorio, R.; Gázquez, M. J.

    2011-12-01

    In this work, an accurate method for the measurement of natural alpha-emitting radionuclides from aerosols collected in air filters is presented and discussed in detail. The knowledge of the levels of several natural alpha-emitting radionuclides (238U, 234U, 232Th, 230Th, 228Th, 226Ra and 210Po) in atmospheric aerosols is essential not only for a better understanding of the several atmospheric processes and changes, but also for a proper evaluation of the potential doses, which can inadvertently be received by the population via inhalation. The proposed method takes into account the presence of intrinsic amounts of these radionuclides in the matrices of the quartz filters used, as well as the possible variation in the humidity of the filters throughout the collection process. In both cases, the corrections necessary in order to redress these levels have been evaluated and parameterized. Furthermore, a detailed study has been performed into the optimisation of the volume of air to be sampled in order to increase the accuracy in the determination of the radionuclides. The method as a whole has been applied for the determination of the activity concentrations of U- and Th-isotopes in aerosols collected at two NORM (Naturally Occurring Radioactive Material) industries located in the southwest of Spain. Based on the levels found, a conservative estimation has been performed to yield the additional committed effective doses to which the workers are potentially susceptible due to inhalation of anthropogenic material present in the environment of these two NORM industries.

  17. LETSGO: a spacecraft-based mission to accurately measure the solar angular momentum with frame-dragging

    CERN Document Server

    Iorio, Lorenzo

    2011-01-01

    LETSGO (LEnse-Thirring Sun-Geo Orbiter) is a proposed space-based mission involving the use of a spacecraft moving along a highly eccentric heliocentric orbit perpendicular to the ecliptic. It aims to accurately measure some important physical properties of the Sun and to test some post-Newtonian features of its gravitational field by continuously monitoring the Earth-probe range. Preliminary sensitivity analyses show that, by assuming a cm-level accuracy in ranging to the spacecraft, it would be possible to detect, in principle, the Lense-Thirring effect on it at a 10^-3-10^-4 level over a timescale of 2 yr, while the larger Schwarzschild component of the solar gravitational field may be sensed with a relative accuracy of about 10^-8-10^-9 during the same temporal interval. The competing range perturbation due to the non-sphericity of the Sun would be a source of systematic error, but it turns out that all the three dynamical features of motion examined affect the Earth-probe range in different ways, allowin...

  18. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  19. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  20. Challenges associated with drunk driving measurement: combining police and self-reported data to estimate an accurate prevalence in Brazil.

    Science.gov (United States)

    Sousa, Tanara; Lunnen, Jeffrey C; Gonçalves, Veralice; Schmitz, Aurinez; Pasa, Graciela; Bastos, Tamires; Sripad, Pooja; Chandran, Aruna; Pechansky, Flavio

    2013-12-01

    Drunk driving is an important risk factor for road traffic crashes, injuries and deaths. After June 2008, all drivers in Brazil were subject to a "Zero Tolerance Law" with a set breath alcohol concentration of 0.1 mg/L of air. However, a loophole in this law enabled drivers to refuse breath or blood alcohol testing as it may self-incriminate. The reported prevalence of drunk driving is therefore likely a gross underestimate in many cities. To compare the prevalence of drunk driving gathered from police reports to the prevalence gathered from self-reported questionnaires administered at police sobriety roadblocks in two Brazilian capital cities, and to estimate a more accurate prevalence of drunk driving utilizing three correction techniques based upon information from those questionnaires. In August 2011 and January-February 2012, researchers from the Centre for Drug and Alcohol Research at the Universidade Federal do Rio Grande do Sul administered a roadside interview on drunk driving practices to 805 voluntary participants in the Brazilian capital cities of Palmas and Teresina. Three techniques which include measures such as the number of persons reporting alcohol consumption in the last six hours but who had refused breath testing were used to estimate the prevalence of drunk driving. The prevalence of persons testing positive for alcohol on their breath was 8.8% and 5.0% in Palmas and Teresina respectively. Utilizing a correction technique we calculated that a more accurate prevalence in these sites may be as high as 28.2% and 28.7%. In both cities, about 60% of drivers who self-reported having drank within six hours of being stopped by the police either refused to perform breathalyser testing; fled the sobriety roadblock; or were not offered the test, compared to about 30% of drivers that said they had not been drinking. Despite the reduction of the legal limit for drunk driving stipulated by the "Zero Tolerance Law," loopholes in the legislation permit many

  1. Precise and accurate measurement of U and Th isotopes via ICP-MS using a single solution

    Science.gov (United States)

    Mertz-Kraus, R.; Sharp, W. D.; Ludwig, K. R.

    2012-04-01

    , allowing the sample's 238U/235U ratio to be measured. In step 3, we monitor peak-tails at half-mass positions (229.5, 231.5, 234.5) and on mass 237 while aspirating sample solution. Tail measurement requires a distinct cup configuration to maintain 238U in the cups; however, no sample is consumed during automated cup reconfiguration. We monitor the accuracy of 234U/238U ratios using CRM 145, which gives a weighted mean atom ratio of (5.2846 ± 0.0029) - 10-5 (all errors 2σ), consistent with published and reference values. The reproducibility of 230Th/238U ratios is monitored using the Schwartzwalder Mine secular-equilibrium standard (SM). We detect no bias in 230Th/238U or 234U/238U ratios measured for SM at beam intensities ranging over a factor of four, consistent with accurate correction for IC yields. Aladdin's cave coral (AC-1) was analyzed to check our ICP-MS method (and the preceding purification by ion exchange) on a carbonate and yields a mean age of 125.43 ± 0.38 ka, in agreement with published values. We are currently applying the method to corals, speleothems, pedogenic coatings, and tufas.

  2. Effect of core strength on the measure of power in the extremities.

    Science.gov (United States)

    Shinkle, Justin; Nesser, Thomas W; Demchak, Timothy J; McMannus, David M

    2012-02-01

    The purpose of this study was to (a) develop a functional field test to assess the role of the core musculature and its impact on sport performance in an athletic population and (b) develop a functional field test to determine how well the core can transfer forces from the lower to the upper extremities. Twenty-five DI collegiate football players performed medicine ball throws (forward, reverse, right, and left) in static and dynamic positions. The results of the medicine ball throws were compared with several athletic performance measurements: 1 repetition maximum (1RM) squat, squat kg/bw, 1RM bench press, bench kg/bw, countermovement vertical jump (CMJ), 40-yd dash (40 yd), and proagility (PrA). Push press power (PWR) was used to measure the transfer of forces through the body. Several correlations were found in both the static and dynamic medicine ball throws when compared with the performance measures. Static reverse correlated with CMJ (r = 0.44), 40 yd (r = 0.5), and PrA (r = 0.46). Static left correlated with bench kg/bw (0.42), CMJ (0.44), 40 yd (0.62), and PrA (0.59). Static right also correlated with bench kg/bw (0.41), 40 yd (0.44), and PrA (0.65). Dynamic forward (DyFw) correlated with the 1RM squat (r = 0.45) and 1RM bench (0.41). Dynamic left and Dynamic right correlated with CMJ, r = 0.48 and r = 0.40, respectively. Push press power correlated with bench kg/bw (0.50), CMJ (0.48), and PrA (0.48). A stepwise regression for PWR prediction identified 1RM squat as the best predictor. The results indicate that core strength does have a significant effect on an athlete's ability to create and transfer forces to the extremities. Currently, plank exercises are considered an adequate method of training the core for athletes to improve core strength and stability. This is a problem because it puts the athletes in a nonfunctional static position that is very rarely replicated in the demands of sport-related activities. The core is the center of most kinetic

  3. Extremely low frequency electromagnetic field measurements at the Hylaty station and methodology of signal analysis

    Science.gov (United States)

    Kulak, Andrzej; Kubisz, Jerzy; Klucjasz, Slawomir; Michalec, Adam; Mlynarczyk, Janusz; Nieckarz, Zenon; Ostrowski, Michal; Zieba, Stanislaw

    2014-06-01

    We present the Hylaty geophysical station, a high-sensitivity and low-noise facility for extremely low frequency (ELF, 0.03-300 Hz) electromagnetic field measurements, which enables a variety of geophysical and climatological research related to atmospheric, ionospheric, magnetospheric, and space weather physics. The first systematic observations of ELF electromagnetic fields at the Jagiellonian University were undertaken in 1994. At the beginning the measurements were carried out sporadically, during expeditions to sparsely populated areas of the Bieszczady Mountains in the southeast of Poland. In 2004, an automatic Hylaty ELF station was built there, in a very low electromagnetic noise environment, which enabled continuous recording of the magnetic field components of the ELF electromagnetic field in the frequency range below 60 Hz. In 2013, after 8 years of successful operation, the station was upgraded by extending its frequency range up to 300 Hz. In this paper we show the station's technical setup, and how it has changed over the years. We discuss the design of ELF equipment, including antennas, receivers, the time control circuit, and power supply, as well as antenna and receiver calibration. We also discuss the methodology we developed for observations of the Schumann resonance and wideband observations of ELF field pulses. We provide examples of various kinds of signals recorded at the station.

  4. Generation and Measurement of Chlorine Dioxide Gas at Extremely Low Concentrations in a Living Room: Implications for Preventing Airborne Microbial Infectious Diseases.

    Science.gov (United States)

    Ogata, Norio; Sogawa, Koushirou; Takigawa, Yasuhiro; Shibata, Takashi

    2017-01-01

    Preventing respiratory diseases caused by airborne microbes in enclosed spaces is still not satisfactorily controlled. At extremely low concentrations (about 30 parts per billion), chlorine dioxide (ClO2) gas can inactivate airborne microbes and prevent respiratory disease. It has no toxic effect on animals at this level. However, controversies still remain regarding how to measure concentrations of ClO2 gas at such low levels. It is therefore necessary to prove that measured gas concentrations are accurate and reproducible. ClO2 gas was released from a gas generator and its concentration was measured by a novel highly sensitive gas analyzer. We compared its data with those from ion chromatography. We demonstrate that the gas concentrations measured in a room using the gas analyzer are accurate and reproducible after comparing the results with those from ion chromatography. However, the temperature dependence of the gas analyzer was found. Therefore, data correction is required for each temperature at which gas concentration is measured. A theoretical analysis of the gas concentrations predicted by the rate of ClO2 gas released from the ClO2 generator was also performed. Our results advance progress toward using low concentration ClO2 gas to prevent airborne infectious diseases such as influenza. © 2016 S. Karger AG, Basel.

  5. Accurate monitoring of intravascular fluid volume: A novel application of intrathoracic impedance measures for the guidance of volume reduction therapy

    Directory of Open Access Journals (Sweden)

    Barbara A. Lara

    2015-09-01

    Conclusion: Impedance vectors derived from a multivector monitoring system reflect changes in intravascular plasma volume. Two of these vectors most closely track changes in plasma volume and may be used to more accurately guide and optimize volume reduction therapy.

  6. Accurate measurement of circulating mitochondrial DNA content from human blood samples using real-time quantitative PCR.

    Science.gov (United States)

    Ajaz, Saima; Czajka, Anna; Malik, Afshan

    2015-01-01

    We describe a protocol to accurately measure the amount of human mitochondrial DNA (MtDNA) in peripheral blood samples which can be modified to quantify MtDNA from other body fluids, human cells, and tissues. This protocol is based on the use of real-time quantitative PCR (qPCR) to quantify the amount of MtDNA relative to nuclear DNA (designated the Mt/N ratio). In the last decade, there have been increasing numbers of studies describing altered MtDNA or Mt/N in circulation in common nongenetic diseases where mitochondrial dysfunction may play a role (for review see Malik and Czajka, Mitochondrion 13:481-492, 2013). These studies are distinct from those looking at genetic mitochondrial disease and are attempting to identify acquired changes in circulating MtDNA content as an indicator of mitochondrial function. However, the methodology being used is not always specific and reproducible. As more than 95 % of the human mitochondrial genome is duplicated in the human nuclear genome, it is important to avoid co-amplification of nuclear pseudogenes. Furthermore, template preparation protocols can also affect the results because of the size and structural differences between the mitochondrial and nuclear genomes. Here we describe how to (1) prepare DNA from blood samples; (2) pretreat the DNA to prevent dilution bias; (3) prepare dilution standards for absolute quantification using the unique primers human mitochondrial genome forward primer (hMitoF3) and human mitochondrial genome reverse primer(hMitoR3) for the mitochondrial genome, and human nuclear genome forward primer (hB2MF1) and human nuclear genome reverse primer (hB2MR1) primers for the human nuclear genome; (4) carry out qPCR for either relative or absolute quantification from test samples; (5) analyze qPCR data; and (6) calculate the sample size to adequately power studies. The protocol presented here is suitable for high-throughput use.

  7. A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Sofía Ruiz de Gauna

    2016-01-01

    Full Text Available Background. Cardiopulmonary resuscitation (CPR feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin’s back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%. Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p<0.001. Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p<0.001. Median error in rate was 0.9 cpm (1.0%, with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces.

  8. The extremity function index (EFI), a disability severity measure for neuromuscular diseases : psychometric evaluation

    NARCIS (Netherlands)

    Bos, Isaac; Wynia, Klaske; Drost, Gea; Almansa, Josué; Kuks, Joannes

    2017-01-01

    OBJECTIVE: To adapt and to combine the self-report Upper Extremity Functional Index and Lower Extremity Function Scale, for the assessment of disability severity in patients with a neuromuscular disease and to examine its psychometric properties in order to make it suitable for indicating disease

  9. Measurement of the severity of disability in community-dwelling adults and older adults: interval-level measures for accurate comparisons in large survey data sets

    Science.gov (United States)

    Buz, José; Cortés-Rodríguez, María

    2016-01-01

    Objectives To (1) create a single metric of disability using Rasch modelling to be used for comparing disability severity levels across groups and countries, (2) test whether the interval-level measures were invariant across countries, sociodemographic and health variables and (3) examine the gains in precision using interval-level measures relative to ordinal scores when discriminating between groups known to differ in disability. Design Cross-sectional, population-based study. Setting/participants Data were drawn from the Survey of Health, Ageing and Retirement in Europe (SHARE), including comparable data across 16 countries and involving 58 489 community-dwelling adults aged 50+. Main outcome measures A single metric of disability composed of self-care and instrumental activities of daily living (IADLs) and functional limitations. We examined the construct validity through the fit to the Rasch model and the know-groups method. Reliability was examined using person separation reliability. Results The single metric fulfilled the requirements of a strong hierarchical scale; was able to separate persons with different levels of disability; demonstrated invariance of the item hierarchy across countries; and was unbiased by age, gender and different health conditions. However, we found a blurred hierarchy of ADL and IADL tasks. Rasch-based measures yielded gains in relative precision (11–116%) in discriminating between groups with different medical conditions. Conclusions Equal-interval measures, with person-invariance and item-invariance properties, provide epidemiologists and researchers with the opportunity to gain better insight into the hierarchical structure of functional disability, and yield more reliable and accurate estimates of disability across groups and countries. Interval-level measures of disability allow parametric statistical analysis to confidently examine the relationship between disability and continuous measures so frequent in health sciences

  10. Penetration Depth Measurements Using a Tunnel Diode Oscillator in Extreme Conditions

    Science.gov (United States)

    Agosta, Charles C.

    2004-03-01

    The tunnel diode oscillator (TDO) has been used as a tool in condensed matter physics for over 30 years. We will discuss the application of the TDO to measure rf penetration depth in small metallic and superconducting samples in the range of 10 -1500 MHz. Our technique involves placing a sample in or on the inductor of a self-resonant tank circuit powered by a tunnel diode, and measuring the impedance of the sample by recording the frequency and amplitude shift as a function of magnetic field or temperature. This technique is very sensitive to the properties of the electrons in a sample, does not require contacts on a sample, can be used for arbitrarily small samples, is very compatible with pulsed magnetic fields, and works well in pressure cells. We will begin by giving a brief history of the TDO in condensed matter physics. We will describe the electronic theory of the TDO showing the important parameters necessary to keep the circuit stable and oscillating in different venues such as very low temperatures and pulsed magnetic fields. We will also describe some of the trade offs between stability and sensitivity in these extreme environments. We will then discuss how to interpret the data produced by the TDO, concentrating on the description of rf penetration in metallic and type II superconducting samples. Finally, as examples of the power of this TDO method, we will show Fermi surface measurements, type II superconducting phase diagrams, including details of the vortex system, and very recent results showing evidence of an inhomogeneous superconducting state. Support for this project has come from the NHMFL and the NSF

  11. Sensibility of GPS measurements and estimates during extreme meteorological events: the case study of mesoscale convective systems in West Africa

    Science.gov (United States)

    Nahmani, S.; Bock, O.

    2013-12-01

    Six permanent GPS stations have been deployed in West Africa within the framework of the African Monsoon Multidisciplinary Analysis (AMMA) project in order to monitor precipitable water vapor (PWV). This quantity is indeed widely employed to compute water budgets and study atmospheric processes. But in Sahel, 90% of annual rainfalls are produced by Mesoscale Convective Systems (MCSs) and PWV estimates tend to be less accurate during these extreme meteorological conditions: temperatures fall, GPS PWV estimates reach a local maximum and GPS phase residuals show strong variations that are spatially and temporally correlated. We observed that GPS phase residuals, which give insight into anomalies of the air refractivity, clearly reveal the passage of MCSs similarly as reflectivity measurements from C-band Doppler radar. The aim of this study is to evaluate the quality of the GPS PWV estimates during these events and possibly improve their estimation process. We carried out methodological and sensitivity tests on the parameterization of atmospheric delays and especially on the Gauss-Markov process which constrains the temporal variability of the GPS PWV estimates. During MCSs events, differences between GPS PWV estimates from GAMIT (2 cm.h-1/2 random walk for zenith tropospheric delays) and GIPSY (5 mm.h-1/2 random walk for zenith tropospheric delays) standard processing can for instance reach +/- 3.8 kg.m-2 . Standard GPS PWV estimates are thus subject to caution during these intense events. We therefore investigate an improved PWV estimation process which considers both zenith tropospheric delays and GPS phase residuals in order to account for the asymmetry of the air refractivity. This method leads to high-frequency PWV estimates for each GPS satellite which we compare with PWV estimates from a collocated microwave radiometer.

  12. Measurement of zone plate efficiencies in the extreme ultraviolet and applications to radiation monitors for absolute spectral emission

    Science.gov (United States)

    Seely, John; Holland, Glenn; Bremer, James C.; Zukowski, Tim; Feser, Michael; Feng, Yan; Kjornrattanawanich, Benjawan; Goray, Leonid

    2006-08-01

    The diffraction efficiencies of a Fresnel zone plate (ZP), fabricated by Xradia Inc. using the electron-beam writing technique, were measured using polarized, monochromatic synchrotron radiation in the extreme ultraviolet wavelength range 3.4-22 nm. The ZP had 2 mm diameter, 3330 zones, 150 nm outer zone width, and a 1 mm central occulter. The ZP was supported by a 100 nm thick Si 3N 4 membrane. The diffraction patterns were recorded by CMOS imagers with phosphor coatings and with 5.2 μm or 48 μm pixels. The focused +n orders (n=1-4), the diverging -1 order, and the undiffracted 0 order were observed as functions of wavelength and off-axis tilt angle. Sub-pixel focusing of the +n orders was achieved. The measured efficiency in the +1 order was in the 5% to 30% range with the phase-shift enhanced efficiency occurring at 8.3 nm where the gold bars are partially transmitting. The +2 and higher order efficiencies were much lower than the +1 order efficiency. The efficiencies were constant when the zone plate was tilted by angles up to +/-1° from the incident radiation beam. This work indicates the feasibility and benefits of using zone plates to measure the absolute EUV spectral emissions from solar and laboratory sources: relatively high EUV efficiency in the focused +1 order, good out-of-band rejection resulting from the low higher-order efficiencies and the ZP focusing properties, insensitivity to (unfocused) visible light scattered by the ZP, flat response with off-axis angle, and insensitivity to the polarization of the radiation based on the ZP circular symmetry. EUV sensors with Fresnel zone plates potentially have many advantages over existing sensors intended to accurately measure absolute EUV emission levels, such as those implemented on the GOES N-P satellites that use transmission gratings which have off-axis sensitivity variations and poor out-of-band EUV and visible light rejection, and other solar and laboratory sensors using reflection gratings which

  13. Driving Extreme Variability - Measuring the evolving coronae and evidence for jet launching in AGN

    CERN Document Server

    Wilkins, D R

    2015-01-01

    Relativistically blurred reflection from the accretion disc provides a powerful probe of the extreme environments close to supermassive black holes; the inner regions of the accretion flow and the corona that produces the intense X-ray continuum. Techniques by which the geometry and extent of the corona can be measured through the observed X-ray spectrum are reviewed along with the evolution in the structure of the corona that is seen to accompany variations in the X-ray luminosity both on long and short timescales. Detailed analyses of the narrow line Seyfert 1 galaxies Markarian 335 and 1H0707-495, over observations with XMM-Newton as well as Suzaku and NuSTAR spanning nearly a decade reveal that increases in the X-ray luminosity coincide with an expansion of the corona to cover a larger area of the inner accretion disc. Underlying this long timescale variability lie more complex patterns of behaviour on short timescales. Flares in the X-ray emission during a low flux state of Mrk 335 observed in 2013 and 2...

  14. S3 HMBC: Spin-State-Selective HMBC for accurate measurement of homonuclear coupling constants. Application to strychnine yielding thirteen hitherto unreported JHH

    DEFF Research Database (Denmark)

    Kjaerulff, Louise; Benie, Andrew J.; Hoeck, Casper

    2016-01-01

    A novel method, Spin-State-Selective (S3) HMBC, for accurate measurement of homonuclear coupling constants is introduced. As characteristic for S3 techniques, S3 HMBC yields independent subspectra corresponding to particular passive spin states and thus allows determination of coupling constants ...... are demonstrated by an application to strychnine where thirteen JHH coupling constants not previously reported could be measured....

  15. Accurately measuring sea level change from space: an ESA Climate Change Initiative for MSL closure budget studies

    DEFF Research Database (Denmark)

    Legeais, Jean-Francois; Cazenave, Anny; Larnicol, Gille

    Sea level is a very sensitive index of climate change and variability. Sea level integrates the ocean warming, mountain glaciers and ice sheet melting. Understanding the sea level variability and changes implies an accurate monitoring of the sea level variable at climate scales, in addition...... in the Arctic Ocean and in coastal areas for which preliminary results suggest that significant improvements can be achieved....

  16. Bias and spread in extreme value theory measurements of probability of error

    Science.gov (United States)

    Smith, J. G.

    1972-01-01

    Extreme value theory is examined to explain the cause of the bias and spread in performance of communications systems characterized by low bit rates and high data reliability requirements, for cases in which underlying noise is Gaussian or perturbed Gaussian. Experimental verification is presented and procedures that minimize these effects are suggested. Even under these conditions, however, extreme value theory test results are not particularly more significant than bit error rate tests.

  17. Prospects for measuring supermassive black hole masses with future extremely large telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Do, Tuan; Wright, Shelley A. [Dunlap Institute for Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto M5S 3H4, ON (Canada); Barth, Aaron J.; Barton, Elizabeth J. [Department of Physics and Astronomy, 4129 Frederick Reines Hall, University of California, Irvine, CA 92697-4575 (United States); Simard, Luc [Herzberg Institute of Astrophysics, National Research Council of Canada, Victoria, BC, V9E 2E7 (Canada); Larkin, James E. [Physics and Astronomy Department, University of California, Los Angeles, CA 90095-1547 (United States); Moore, Anna M. [Caltech Optical Observatories, California Institute of Technology, Pasadena, CA (United States); Wang, Lianqi; Ellerbroek, Brent [TMT Observatory Corporation Instrumentation Department, Pasadena, CA (United States)

    2014-04-01

    The next generation of giant-segmented mirror telescopes (>20 m) will enable us to observe galactic nuclei at much higher angular resolution and sensitivity than ever before. These capabilities will introduce a revolutionary shift in our understanding of the origin and evolution of supermassive black holes by enabling more precise black hole mass measurements in a mass range that is unreachable today. We present simulations and predictions of the observations of nuclei that will be made with the Thirty Meter Telescope (TMT) and the adaptive optics assisted integral-field spectrograph IRIS, which is capable of diffraction-limited spectroscopy from Z band (0.9 μm) to K band (2.2 μm). These simulations, for the first time, use realistic values for the sky, telescope, adaptive optics system, and instrument to determine the expected signal-to-noise ratio of a range of possible targets spanning intermediate mass black holes of ∼10{sup 4} M {sub ☉} to the most massive black holes known today of >10{sup 10} M {sub ☉}. We find that IRIS will be able to observe Milky Way mass black holes out the distance of the Virgo Cluster, and will allow us to observe many more of the brightest cluster galaxies where the most massive black holes are thought to reside. We also evaluate how well the kinematic moments of the velocity distributions can be constrained at the different spectral resolutions and plate scales designed for IRIS. We find that a spectral resolution of ∼8000 will be necessary to measure the masses of intermediate mass black holes. By simulating the observations of galaxies found in Sloan Digital Sky Survey DR7, we find that over 10{sup 5} massive black holes will be observable at distances between 0.005 < z < 0.18 with the estimated sensitivity and angular resolution provided by access to Z-band (0.9 μm) spectroscopy from IRIS and the TMT adaptive optics system. These observations will provide the most accurate dynamical measurements of black hole masses to

  18. Cross-Cultural Adaptation and Validation of the Lower Extremity Measure Into German

    Science.gov (United States)

    Käch, Kurt; Frei, Hans Curd; Rudin, Mark; Leimbacher, Melanie; Platz, Andreas

    2015-01-01

    Introduction: The Lower Extremity Measure (LEM) was developed to provide a specific instrument to detect changes in physical function in patients with hip fracture. Of 29 questions, 3 have a valid “not applicable” answer option. The goal of this study was to validate the LEM in German and to determine the added value to the physical functioning (pf) subscale of the Short Form 36 (SF-36). Materials and Methods: The LEM was translated according to published guidelines and administered to patients with hip fracture (31 A1-A3 and 31 B1-B3) shortly after surgery (baseline), at 3 months (3M), and for reliability testing at 3 months plus 1 week (3M+). The reproducibility, internal consistency, floor and ceiling effects, construct validity, and responsiveness of the German LEM were assessed. Results: A total of 106 patients completed the LEM and SF-36 (mean age 75.5; 67% women) at baseline (mean of 4.9 days after operation), and 88 completed both questionnaires at both the 3M and 3M+ assessments. At each assessment time point, between 6% and 23% of the patients answered 7 questions as “not applicable.” Reproducibility and internal consistency were high (intraclass correlation coefficient = 0.93; Cronbach's α = .96). No floor effect (0%) and a minor ceiling effect (7.87%) were found for the total LEM score. The strongest correlation was found between the LEM and the SF-36 subscale pf (Spearman ρ = .93). Responsiveness was similar for the SF-36 pf subscale and the LEM when using effect size (SF-36 pf 0.71 vs LEM 0.72) and better for the LEM when using standardized response mean (SF-36 pf 0.65 vs LEM 0.76). Discussion: The German LEM is a reliable, valid, and responsive measure for the self-assessment of patients after hip fracture surgery. As a number of questions are not applicable to elderly patients, the added value of this lengthy questionnaire in these often frail, sometimes cognitively impaired patients is still open for debate. PMID:26623163

  19. Evaluation of accurate mass and relative isotopic abundance measurements in the LTQ-orbitrap mass spectrometer for further metabolomics database building.

    Science.gov (United States)

    Xu, Ying; Heilier, Jean-François; Madalinski, Geoffrey; Genin, Eric; Ezan, Eric; Tabet, Jean-Claude; Junot, Christophe

    2010-07-01

    Recently, high-resolution mass spectrometry has been largely employed for compound identification, thanks to accurate mass measurements. As additional information, relative isotope abundance (RIA) is often needed to reduce the number of candidates prior to tandem MS(n). Here, we report on the evaluation of the LTQ-Orbitrap, in terms of accurate mass and RIA measurements for building further metabolomics spectral databases. Accurate mass measurements were achieved in the ppm range, using external calibration within 24 h, and remained at evaluated in different data sets. First of all, 137 solutions of commercial compounds were analyzed by flow injection analysis in both the positive and negative ion modes. It was found that the ion abundance was the main factor impacting the accuracy of RIA measurements. It was possible to define some intensity thresholds above which errors were systematically transmission between the LTQ ion trap and the Orbitrap analyzer on RIA measurement errors was found, whereas the reliability of RIA measurements was dramatically improved by reducing the mass detection window. It was also observed that the signal integration method had a significant impact on RIA measurement errors, with the most-reliable results being obtained with peak height integrations. Finally, automatic integrations using the data preprocessing software XCMS and MZmine gave results similar to those obtained by manual integration, suggesting that it is relevant to use the RIA information in automatic elemental composition determination software from metabolomic peak tables.

  20. Accounting for Interference, Scattering, and Electrode Absorption to Make Accurate Internal Quantum Efficiency Measurements in Organic and Other Thin Solar Cells

    KAUST Repository

    Burkhard, George F.

    2010-05-31

    Accurately measuring internal quantum efficiency requires knowledge of absorption in the active layer of a solar cell. The experimentally accessible total absorption includes significant contributions from the electrodes and other nonactive layers. We suggest a straightforward method for calculating the active layer contribution that minimizes error by subtracting optically-modeled electrode absorption from experimentally measured total absorption. (Figure Presented) © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Can endocranial volume be estimated accurately from external skull measurements in great-tailed grackles (Quiscalus mexicanus)?

    National Research Council Canada - National Science Library

    Logan, Corina J; Palmstrom, Christin R

    2015-01-01

    ...), as measured by computerized tomography (CT) scans, using external skull measurements and/or by filling skulls with beads and pouring them out into a graduated cylinder for male and female great-tailed grackles...

  2. Application of measurement configuration optimization for accurate metrology of sub-wavelength dimensions in multilayer gratings using optical scatterometry.

    Science.gov (United States)

    Zhu, Jinlong; Shi, Yating; Goddard, Lynford L; Liu, Shiyuan

    2016-09-01

    Critical dimension measurement accuracy in optical scatterometry relies not only on the systematic noise level of instruments and the reliability of forward modeling algorithms, but also heavily on the measurement configuration. To construct a set of potentially high-accuracy configurations, we apply a general measurement configuration optimization method based on error propagation theory and singular value decomposition, by which the measurement accuracy is approximated as a function of a pseudo Jacobian with respect to the measurement configurations. Simulations and experiments for the optical metrology of a sub-wavelength deep-etched multilayer grating establish the feasibility of the proposed method.

  3. Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Jørgensen, Jesper Tranekjaer; Binderup, Tina;

    2008-01-01

    and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evaluated the accuracy of tumor volume determined from 18F-fluorodeoxyglucose (18F-FDG) PET. METHODS: Subcutaneously implanted human breast adenocarcinoma cells in NMRI nude mice served as tumor model. Tumor volume...... systematic bias compared to reference volume. Coefficients of variation for intra-observer variation were 7% and 14% for microCT and caliper measurements, respectively. Regression coefficients between observers were 0.97 for microCT and 0.91 for caliper measurements. CONCLUSION: MicroCT was more accurate...

  4. Technical Note: How accurate can stalagmite formation temperatures be determined using vapour bubble radius measurements in fluid inclusions?

    DEFF Research Database (Denmark)

    Spadin, F.; Marti, Dominik; Hidalgo-Staub, R.

    2015-01-01

    Stalagmites are natural archives containing detailed information on continental climate variability of the past. Microthermometric measurements of fluid inclusion homogenisation temperatures allow determination of stalagmite formation temperatures by measuring the radius of stable laser-induced v......Stalagmites are natural archives containing detailed information on continental climate variability of the past. Microthermometric measurements of fluid inclusion homogenisation temperatures allow determination of stalagmite formation temperatures by measuring the radius of stable laser......-induced vapour bubbles inside the inclusions. A reliable method for precisely measuring the radius of vapour bubbles is presented. The method is applied to stalagmite samples for which the formation temperature is known. An assessment of the bubble radius measurement accuracy and how this error influences...

  5. Two-dimensional Moiré phase analysis for accurate strain distribution measurement and application in crack prediction.

    Science.gov (United States)

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Koyama, Motomichi; Tsuzaki, Kaneaki

    2017-06-12

    Aimed at the low accuracy problem of shear strain measurement in Moiré methods, a two-dimensional (2D) Moiré phase analysis method is proposed for full-field deformation measurement with high accuracy. A grid image is first processed by the spatial phase-shifting sampling Moiré technique to get the Moiré phases in two directions, which are then conjointly analyzed for measuring 2D displacement and strain distributions. The strain especially the shear strain measurement accuracy is remarkably improved, and dynamic deformation is measurable from automatic batch processing of single-shot grid images. As an application, the 2D microscale strain distributions of a titanium alloy were measured, and the crack occurrence location was successfully predicted from strain concentration.

  6. Determination of representative renal depth for accurate attenuation corred in measurement of glomerular filtration rate in transplanted kidney

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Soon Nam; Kim, Sung Hoon; Rha, Sung Eun; Chung, Yong An; Yoo, Ie Ryung; Sohn, Hyung Sun; Lee, Sung Young; Chung, Soo Kyo [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2002-08-01

    To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured DFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depth under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are 4.09{+-}0.65 cm in men, and 4.24{+-}0.78 cm in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

  7. Two instruments based on differential optical absorption spectroscopy (DOAS) to measure accurate ammonia concentrations in the atmosphere

    NARCIS (Netherlands)

    Volten, H.; Bergwerff, J.B.; Haaima, M.; Lolkema, D.E.; Berkhout, A.J.C.; Hoff, G.R.; Potma, C.J.M.; Wichink Kruit, R.J.; Pul, van W.A.J.; Swart, D.P.J.

    2012-01-01

    We present two Differential Optical Absorption Spectroscopy (DOAS) instruments built at RIVM: the RIVM DOAS and the miniDOAS. Both instruments provide virtually interference-free measurements of NH3 concentrations in the atmosphere, since they measure over an open path, without suffering from inlet

  8. S3 HMBC hetero: Spin-State-Selective HMBC for accurate measurement of long-range heteronuclear coupling constants

    DEFF Research Database (Denmark)

    Hoeck, Casper; Gotfredsen, Charlotte Held; Sørensen, Ole W.

    2017-01-01

    A novel method, Spin-State-Selective (S3) HMBC hetero, for accurate measurement of heteronuclear coupling constants is introduced. The method extends the S3 HMBC technique for measurement of homonuclear coupling constants by appending a pulse sequence element that interchanges the polarization in...... of techniques, the accuracy of coupling constant measurement is independent of the size of the coupling constant of interest. The merits of the new method are demonstrated by application to vinyl acetate, the alkaloid strychnine, and the carbohydrate methyl β-maltoside....

  9. Finite Element Modelling of a Field-Sensed Magnetic Suspended System for Accurate Proximity Measurement Based on a Sensor Fusion Algorithm with Unscented Kalman Filter

    Directory of Open Access Journals (Sweden)

    Amor Chowdhury

    2016-09-01

    Full Text Available The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation.

  10. Finite Element Modelling of a Field-Sensed Magnetic Suspended System for Accurate Proximity Measurement Based on a Sensor Fusion Algorithm with Unscented Kalman Filter.

    Science.gov (United States)

    Chowdhury, Amor; Sarjaš, Andrej

    2016-09-15

    The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation.

  11. Extreme Risk Measurement Based on EVT-POT-SV-MT Model%基于EVT-POT-SV-MT模型的极值风险度量

    Institute of Scientific and Technical Information of China (English)

    董耀武; 周孝华; 姜婷

    2012-01-01

    针对金融资产收益的异常变化,采用SV-MT模型对风险资产的预期收益做风险补偿并捕捉收益序列的厚尾性、波动的异方差性等特征,将收益序列转化为标准残差序列,通过SV-MT模型与极值理论相结合拟合标准残差的尾部分布,建立了一种新的金融风险度量模型——基于EVT-POT-SV-MT的动态VaR模型.通过该模型对上证综指做实证分析,结果表明该模型能够合理有效地度量上证综指收益的风险.%VaR (Value at Risk) is an important method of risk management, which is used to measure the maximum possible loss of a portfolio in a selected confidence level at a given period of time in the future. The primary purpose of this method is to describe the volatility of financial time series as accurate as possible. Analysis methods are primarily used to predict management risk in VaR. The accuracy of the analysis result is mainly reflected in the financial asset of the error term distribution settings and volatility forecast. Because of the variability of financial markets, the traditional non-conditional normal distribution assumption is no longer applicable, and the conditional normal distribution or conditional distribution which is more characterized by fat tail is more in line with actual market volatility and return distribution.The relationship between the risk and expected rate of return is an important part of the modern financial theory. Many modern asset pricing models are based on the assumption that investors are risk-averse. Risk-averse investors holding risky assets require appropriate risk premium. Because the risk of a risky asset can be measured by the variance of returns, the risk premium is the increasing function of the conditional income variance. The traditional financial theory and statistical methods designed to deal with the extreme financial market volatility have many kinds of flaws. More scholars begin to try to introduce extreme value theory to

  12. Accurate measurement of the cutoff wavelength in a microstructured optical fiber by means of an azimutal filtering technique

    CERN Document Server

    Labonte, Laurent; Roy, Philippe; Balhoul, Faouzi; Zghal, Mourad; Melin, Gilles; Burov, Ekaterina; Renversez, Gilles

    2010-01-01

    A simple self-referenced non destructive method is proposed for measuring the cutoff wavelength of microstructured optical fibers (MOFs). It is based on the analysis of the time dependent optical power transmitted through a bow-tie slit rotating in the far-field pattern of the fiber under test. As a first demonstration, the cutoff wavelength of a 2m MOF sample is measured with a precision of 10nm, in good agreement with theoretical predictions.

  13. Can shoulder range of movement be measured accurately using the Microsoft Kinect sensor plus Medical Interactive Recovery Assistant software?

    Science.gov (United States)

    Wilson, James D; Khan-Perez, Jennifer; Marley, Dominic; Buttress, Susan; Walton, Michael; Li, Baihua; Roy, Bibhas

    2017-08-30

    This study compared the accuracy of measuring shoulder range of movement (ROM) with a simple laptop-sensor combination vs. trained observers (shoulder physiotherapists and shoulder surgeons) using motion capture (MoCap) laboratory equipment as the gold standard. The Microsoft Kinect sensor (Microsoft Corp., Redmond, WA, USA) tracks 3-dimensional human motion. Ordinarily used with an Xbox (Microsoft Corp.) video game console, Medical Interactive Recovery Assistant (MIRA) software (MIRA Rehab Ltd., London, UK) allows this small sensor to measure shoulder movement with a standard computer. Shoulder movements of 49 healthy volunteers were simultaneously measured by trained observers, MoCap, and the MIRA device. Internal rotation was assessed with the shoulder abducted 90° and external rotation with the shoulder adducted. Visual estimation and MIRA measurements were compared with gold standard MoCap measurements for agreement using Bland-Altman methods. There were 1670 measurements analyzed. The MIRA evaluations of all 4 cardinal shoulder movements were significantly more precise, with narrower limits of agreement, than the measurements of trained observers. MIRA achieved ±11° (95% confidence interval [CI], 8.7°-12.6°) for forward flexion vs. ±16° (95% CI, 14.6°-17.6°) by trained observers. For abduction, MIRA showed ±11° (95% CI, 8.7°-12.8°) against ±15° (95% CI, 13.4°-16.2°) for trained observers. MIRA attained ±10° (95% CI, 8.1°-11.9°) during external rotation measurement, whereas trained observers only reached ±21° (95% CI, 18.7°-22.6°). For internal rotation, MIRA achieved ±9° (95% CI, 7.2°-10.4°), which was again better than TOs at ±18° (95% CI, 16.0°-19.3°). A laptop combined with a Microsoft Kinect sensor and the MIRA software can measure shoulder movements with acceptable levels of accuracy. This technology, which can be easily set up, may also allow precise shoulder ROM measurement outside the clinic setting. Copyright © 2017

  14. Advancing Solar Irradiance Measurement for Climate-Related Studies: Accurate Constraint on Direct Aerosol Radiative Effect (DARE)

    Science.gov (United States)

    Tsay, Si-Chee; Ji, Q. Jack

    2011-01-01

    Earth's climate is driven primarily by solar radiation. As summarized in various IPCC reports, the global average of radiative forcing for different agents and mechanisms, such as aerosols or CO2 doubling, is in the range of a few W/sq m. However, when solar irradiance is measured by broadband radiometers, such as the fleet of Eppley Precision Solar Pyranometers (PSP) and equivalent instrumentation employed worldwide, the measurement uncertainty is larger than 2% (e.g., WMO specification of pyranometer, 2008). Thus, out of the approx. 184 W/sq m (approx.263 W/sq m if cloud-free) surface solar insolation (Trenberth et al. 2009), the measurement uncertainty is greater than +/-3.6 W/sq m, overwhelming the climate change signals. To discern these signals, less than a 1 % measurement uncertainty is required and is currently achievable only by means of a newly developed methodology employing a modified PSP-like pyranometer and an updated calibration equation to account for its thermal effects (li and Tsay, 2010). In this talk, we will show that some auxiliary measurements, such as those from a collocated pyrgeometer or air temperature sensors, can help correct historical datasets. Additionally, we will also demonstrate that a pyrheliometer is not free of the thermal effect; therefore, comparing to a high cost yet still not thermal-effect-free "direct + diffuse" approach in measuring surface solar irradiance, our new method is more economical, and more likely to be suitable for correcting a wide variety of historical datasets. Modeling simulations will be presented that a corrected solar irradiance measurement has a significant impact on aerosol forcing, and thus plays an important role in climate studies.

  15. Using participatory agent-based models to measure flood managers' decision thresholds in extreme event response

    Science.gov (United States)

    Metzger, A.; Douglass, E.; Gray, S. G.

    2016-12-01

    Extreme flooding impacts to coastal cities are not only a function of storm characteristics, but are heavily influenced by decision-making and preparedness in event-level response. While recent advances in climate and hydrological modeling make it possible to predict the influence of climate change on storm and flooding patterns, flood managers still face a great deal of uncertainty related to adapting organizational responses and decision thresholds to these changing conditions. Some decision thresholds related to mitigation of extreme flood impacts are well-understood and defined by organizational protocol, but others are difficult to quantify due to reliance on contextual expert knowledge, experience, and complexity of information necessary to make certain decisions. Our research attempts to address this issue by demonstrating participatory modeling methods designed to help flood managers (1) better understand and parameterize local decision thresholds in extreme flood management situations, (2) collectively learn about scaling management decision thresholds to future local flooding scenarios and (3) identify effective strategies for adaptating flood mitigation actions and organizational response to climate change-intensified flooding. Our agent-based system dynamic models rely on expert knowledge from local flood managers and sophisticated, climate change-informed hydrological models to simulate current and future flood scenarios. Local flood managers from interact with these models by receiving dynamic information and making management decisions as a flood scenario progresses, allowing parametrization of decision thresholds under different scenarios. Flooding impacts are calculated in each iteration as a means of discussing effectiveness of responses and prioritizing response alternatives. We discuss the findings of this participatory modeling and educational process from a case study of Boston, MA, and discuss transferability of these methods to other types

  16. Extrapolation of Extreme Response for Wind Turbines based on FieldMeasurements

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2009-01-01

    The characteristic loads on wind turbines during operation are among others dependent on the mean wind speed, the turbulence intensity and the type and settings of the control system. These parameters must be taken into account in the assessment of the characteristic load. The characteristic load...... extrapolation are presented. The first method is based on the same assumptions as the existing method but the statistical extrapolation is only performed for a limited number of mean wind speeds where the extreme load is likely to occur. For the second method the mean wind speeds are divided into storms which...

  17. Accurate in vivo dielectric properties of liver from 500 MHz to 40 GHz and their correlation to ex vivo measurements.

    Science.gov (United States)

    Farrugia, L; Wismayer, P Schembri; Mangion, L Zammit; Sammut, C V

    2016-01-01

    In this article, we report on the characterization of the dielectric properties of in vivo rat liver at 36.4°C from 500 MHz up to 40 GHz with less than 5% uncertainty. The measured data were fitted to a Cole-Cole model and dielectric parameters are presented together with their respective 95% confidence interval. The root mean square error is 0.42. Moreover, ex vivo measurements were conducted in situ at 1, 2, 4 and 6 min after animal death and are compared to in vivo measurements. The results show that immediate changes in [Formula: see text]and [Formula: see text] are within experimental uncertainty, and therefore changes between in vivo and published ex vivo dielectric properties can be attributed to tissue hydration.

  18. Assignment of resonances in dissociative recombination of HD+ ions: high-resolution measurements compared with accurate computations

    CERN Document Server

    Tamo, F O Waffeu; Motapon, O; Altevogt, S; Andrianarijaona, V M; Grieser, M; Lammich, L; Lestinsky, M; Motsch, M; Nevo, I; Novotny, S; Orlov, D A; Pedersen, H B; Schwalm, D; Sprenger, F; Urbain, X; Weigel, U; Wolf, A; Schneider, I F

    2011-01-01

    The collision-energy resolved rate coefficient for dissociative recombination of HD+ ions in the vibrational ground state is measured using the photocathode electron target at the heavy-ion storage ring TSR. Rydberg resonances associated with ro-vibrational excitation of the HD+ core are scanned as a function of the electron collision energy with an instrumental broadening below 1 meV in the low-energy limit. The measurement is compared to calculations using multichannel quantum defect theory, accounting for rotational structure and interactions and considering the six lowest rotational energy levels as initial ionic states. Using thermal equilibrium level populations at 300 K to approximate the experimental conditions, close correspondence between calculated and measured structures is found up to the first vibrational excitation threshold of the cations near 0.24 eV. Detailed assignments, including naturally broadened and overlapping Rydberg resonances, are performed for all structures up to 0.024 eV. Resona...

  19. Is a standalone inertial measurement unit accurate and precise enough for quantification of movement symmetry in the horse?

    DEFF Research Database (Denmark)

    Brighton, Charlotte; Olsen, Emil; Pfau, Thilo

    2015-01-01

    Standalone ‘low-cost’ inertial measurement units (IMUs) could facilitate large-scale studies into establishing minimal important differences (MID) for orthopaedic deficits (lameness) in horses. We investigated accuracy and limits of agreement (LoA) after correction of magnitude-dependent differen......Standalone ‘low-cost’ inertial measurement units (IMUs) could facilitate large-scale studies into establishing minimal important differences (MID) for orthopaedic deficits (lameness) in horses. We investigated accuracy and limits of agreement (LoA) after correction of magnitude......-dependent differences of a standalone 6 degree-of-freedom IMU compared with an established IMU-based gait analysis system (MTx) in six horses for two anatomical landmarks (sacrum and sternum). Established symmetry measures were calculated from vertical displacement: symmetry index (SI), difference between minima (Min...

  20. Accurate tissue area measurements with considerably reduced radiation dose achieved by patient-specific CT scan parameters

    DEFF Research Database (Denmark)

    Brandberg, J.; Bergelin, E.; Sjostrom, L.

    2008-01-01

    for muscle tissue. Image noise was quantified by standard deviation measurements. The area deviation was radiation dose of the low-dose technique was reduced to 2-3% for diameters of 31-35 cm and to 7.5-50% for diameters of 36-47 cm......A low-dose technique was compared with a standard diagnostic technique for measuring areas of adipose and muscle tissue and CT numbers for muscles in a body composition application. The low-dose technique was intended to keep the expected deviation in the measured area of adipose and muscle tissue...... to low-dose technique. 17 patients - chosen to cover a wide range of diameters (31-47 cm) for both abdomen and thighs - were examined using both techniques. Tissue areas were compared, as were CT numbers...

  1. Accurate measurement of muscle belly length in the motion analysis laboratory: potential for the assessment of contracture.

    Science.gov (United States)

    Fry, N R; Childs, C R; Eve, L C; Gough, M; Robinson, R O; Shortland, A P

    2003-04-01

    Two-dimensional ultrasound imaging was combined with motion analysis technology to measure distances between remote anatomical landmarks. The length of the belly of the medial gastrocnemius muscle in five normal adults (nine limbs) was estimated using this technique. Our results in vivo were similar to the reported data for the lengths of muscles in cadavers, and were consistent with the expected relationship between muscle belly length and ankle joint angle. Experiments in vitro demonstrated that the accuracy of the device was better than 2 mm over 20 cm. Measurements on the same subject on different occasions showed that the results were repeatable in vivo. Rendering of the reconstructed volume of a foam phantom gave results comparable to photographic images. This validated technique could be used to measure muscle lengths in children with spastic cerebral palsy and indicate which muscles had fixed shortening, and to what extent.

  2. Accurate perioperative flow measurement of the portal vein and hepatic and renal artery: A role for preoperative MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Vermeulen, Mechteld A.R., E-mail: mar.vermeulen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Ligthart-Melis, Gerdien C., E-mail: g.ligthart-melis@vumc.nl [Department of Internal Medicine, Dietetics and Nutritional Sciences, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Buijsman, René, E-mail: renebuysman@gmail.com [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Siroen, Michiel P.C., E-mail: m.siroen6@upcmail.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Poll, Marcel C.G. van de, E-mail: mcg.vandepoll@ah.unimaas.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Boelens, Petra G., E-mail: p.boelens@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Dejong, Cornelis H.C., E-mail: chc.dejong@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Schaik, Cors van, E-mail: c.vanschaik@vumc.nl [Department of Radiology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Hofman, Mark B.M., E-mail: mbm.hofman@vumc.nl [Department of Physics and Medical Technology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Leeuwen, Paul A.M. van, E-mail: pam.vleeuwen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands)

    2012-09-15

    Background: Quantification of abdominal blood flow is essential for a variety of gastrointestinal and hepatic topics such as liver transplantation or metabolic flux measurement, but those need to be performed during surgery. It is not clear whether Duplex Doppler Ultrasound during surgery or MRI before surgery is the tool to choose. Objective: To examine whether preoperative evaluation of abdominal blood flow using MRI could prove to be a useful and reliable alternative for the perioperative sonographic approach. Methods: In this study portal and renal venous flow and hepatic arterial flow were sequentially quantified by preoperative MRI, preoperative and perioperative Duplex Doppler Ultrasound (DDUS). 55 Patients scheduled for major abdominal surgery were studied and methods and settings were compared. Additionally, average patient population values were compared. Results: Mean (±SD) plasmaflow measured by perioperative DDUS, preoperative DDUS and MRI, respectively was 433 ± 200/423 ± 162/507 ± 96 ml/min (portal vein); 96 ± 70/74 ± 41/108 ± 91 ml/min (hepatic artery); 248 ± 139/201 ± 118/219 ± 69 ml/min (renal vein). No differences between the different settings of DDUS measurement were detected. Equality of mean was observed for all measurements. Bland Altman Plots showed widespread margins. Hepatic arterial flow measurements correlated with each other, but portal and renal venous flow correlations were absent. Conclusions: Surgery and method (DDUS vs. MRI) do not affect mean flow values. Individual comparison is restricted due to wide range in measurements. Since MRI proves to be more reliable with respect to inter-observer variability, we recommend using mean MRI results in experimental setups.

  3. Technical Note: How accurate can stalagmite formation temperatures be determined using vapour bubble radius measurements in fluid inclusions?

    Directory of Open Access Journals (Sweden)

    F. Spadin

    2015-06-01

    Full Text Available Stalagmites are natural archives containing detailed information on continental climate variability of the past. Microthermometric measurements of fluid inclusion homogenisation temperatures allow determination of stalagmite formation temperatures by measuring the radius of stable laser-induced vapour bubbles inside the inclusions. A reliable method for precisely measuring the radius of vapour bubbles is presented. The method is applied to stalagmite samples for which the formation temperature is known. An assessment of the bubble radius measurement accuracy and how this error influences the uncertainty in determining the formation temperature is provided. We demonstrate that the nominal homogenisation temperature of a single inclusion can be determined with an accuracy of ±0.25 °C, if the volume of the inclusion is larger than 105 μm3. With this method, we could measure in a proof-of-principle investigation that the formation temperature of 10–20 yr old inclusions in a stalagmite taken from the Milandre cave is 9.87 ± 0.80 °C, while the mean annual surface temperature, that in the case of the Milandre cave correlates well with the cave temperature, was 9.6 ± 0.15 °C, calculated from actual measurements at that time, showing a very good agreement. Formation temperatures of inclusions formed during the last 450 yr are found in a temperature range between 8.4 and 9.6 °C, which corresponds to the calculated average surface temperature. Paleotemperatures can thus be determined within ±1.0 °C.

  4. Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement

    DEFF Research Database (Denmark)

    Campbell, Duncan J; Nussberger, Juerg; Stowasser, Michael

    2009-01-01

    BACKGROUND: Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown...... are susceptible to renin overestimation due to prorenin activation. In addition, activity assays performed with peptidase inhibitors may overestimate the degree of inhibition of PRA by renin inhibitor therapy. Moreover, immunoassays may overestimate the reactive increase in plasma renin concentration in response...

  5. Recovery trends of Scrobicularia plana populations after restoration measures, affected by extreme climate events.

    Science.gov (United States)

    Verdelhos, T; Cardoso, P G; Dolbeth, M; Pardal, M A

    2014-07-01

    The Mondego estuary (Portugal) went through different ecological scenarios over the last decades. An eutrophication process led to a decline in the ecosystem quality. The ensuing restoration plan resulted into a gradual ecological recovery, which was impaired by the occurrence of successive extreme climate events that affected dynamics and productivity of key species. In this study we assess the response of the bivalve Scrobicularia plana to the impacts of these events in a recovery scenario, by comparing populations in two different intertidal habitats: a seagrass bed and a sandflat area. As a general tendency, S. plana, which was negatively affected by eutrophication, responded positively to restoration. However, the occurrence of extreme climate events seemed to affect recruitment success, biomass and production, impairing the recovery process. In the seagrass bed, S. plana maintained a stable and structured population, while in the sandflat area recovery clearly reverted into a decline, mainly concerning biomass and production values. This sequence of multiple stressors might have reduced S. plana resilience to further impacts and therefore, understanding the behavior of biological populations following restoration initiatives requires acknowledgement that some changes may not be easily reversible.

  6. Atom interferometry experiments with lithium. Accurate measurement of the electric polarizability; Experiences d'interferometrie atomique avec le lithium. Mesure de precision de la polarisabilite electrique

    Energy Technology Data Exchange (ETDEWEB)

    Miffre, A

    2005-06-15

    Atom interferometers are very sensitive tools to make precise measurements of physical quantities. This study presents a measurement of the static electric polarizability of lithium by atom interferometry. Our result, {alpha} = (24.33 {+-} 0.16)*10{sup -30} m{sup 3}, improves by a factor 3 the most accurate measurements of this quantity. This work describes the tuning and the operation of a Mach-Zehnder atom interferometer in detail. The two interfering arms are separated by the elastic diffraction of the atomic wave by a laser standing wave, almost resonant with the first resonance transition of lithium atom. A set of experimental techniques, often complicated to implement, is necessary to build the experimental set-up. After a detailed study of the atom source (a supersonic beam of lithium seeded in argon), we present our experimental atom signals which exhibit a very high fringe visibility, up to 84.5 % for first order diffraction. A wide variety of signals has been observed by diffraction of the bosonic isotope at higher diffraction orders and by diffraction of the fermionic less abundant isotope. The quality of these signals is then used to do very accurate phase measurements. A first experiment investigates how the atom interferometer signals are modified by a magnetic field gradient. An absolute measurement of lithium atom electric polarizability is then achieved by applying a static electric field on one of the two interfering arms, separated by only 90 micrometers. The construction of such a capacitor, its alignment in the experimental set-up and its operation are fully detailed.We obtain a very accurate phase measurement of the induced Lo Surdo - Stark phase shift (0.07 % precision). For this first measurement, the final uncertainty on the electric polarizability of lithium is only 0.66 %, and is dominated by the uncertainty on the atom beam mean velocity, so that a further reduction of the uncertainty can be expected. (author)

  7. The use of electrolysis for accurate delta O-17 and delta O-18 isotope measurements in water

    NARCIS (Netherlands)

    Meijer, HAJ; Li, WJ

    1998-01-01

    We present a new system to measure the relative isotopic abundances of both rare isotopes of oxygen in water. Using electrolysis with CuSO4 as electrolyte, water is transformed into oxygen gas. This gas is subsequently analyzed with a standard Isotope Ratio Mass Spectrometer. We investigated the fea

  8. Highly precise and accurate terahertz polarization measurements based on electro-optic sampling with polarization modulation of probe pulses.

    Science.gov (United States)

    Nemoto, Natsuki; Higuchi, Takuya; Kanda, Natsuki; Konishi, Kuniaki; Kuwata-Gonokami, Makoto

    2014-07-28

    We have developed an electro-optic (EO) sampling method with polarization modulation of probe pulses; this method allows us to measure the direction of a terahertz (THz) electric-field vector with a precision of 0.1 mrad in a data acquisition time of 660 ms using a 14.0-kHz repetition rate pulsed light source. Through combination with a THz time-domain spectroscopy technique, a time-dependent two-dimensional THz electric field was obtained. We used a photoelastic modulator for probe-polarization modulation and a (111)-oriented zincblende crystal as the EO crystal. Using the tilted pulse front excitation method with stable regeneratively amplified pulses, we prepared stable and intense THz pulses and performed pulse-by-pulse analog-to-digital conversion of the signals. These techniques significantly reduced statistical errors and enabled sub-mrad THz polarization measurements. We examined the performance of this method by measuring a wire-grid polarizer as a sample. The present method will open a new frontier of high-precision THz polarization sensitive measurements.

  9. The use of electrolysis for accurate delta O-17 and delta O-18 isotope measurements in water

    NARCIS (Netherlands)

    Meijer, HAJ; Li, WJ

    1998-01-01

    We present a new system to measure the relative isotopic abundances of both rare isotopes of oxygen in water. Using electrolysis with CuSO4 as electrolyte, water is transformed into oxygen gas. This gas is subsequently analyzed with a standard Isotope Ratio Mass Spectrometer. We investigated the

  10. Accurate and Integrated Localization System for Indoor Environments Based on IEEE 802.11 Round-Trip Time Measurements

    Directory of Open Access Journals (Sweden)

    Lorenzo RubénMateo

    2010-01-01

    Full Text Available The presence of (Non line of Sight NLOS propagation paths has been considered the main drawback for localization schemes to estimate the position of a (Mobile User MU in an indoor environment. This paper presents a comprehensive wireless localization system based on (Round-Trip Time RTT measurements in an unmodified IEEE 802.11 wireless network. It overcomes the NLOS impairment by implementing the (Prior NLOS Measurements Correction PNMC technique. At first, the RTT measurements are performed with a novel electronic circuit avoiding the need for time synchronization between wireless nodes. At second, the distance between the MU and each reference device is estimated by using a simple linear regression function that best relates the RTT to the distance in (Line of Sight LOS. Assuming that LOS in an indoor environment is a simplification of reality hence, the PNMC technique is applied to correct the NLOS effect. At third, assuming known the position of the reference devices, a multilateration technique is implemented to obtain the MU position. Finally, the localization system coupled with measurements demonstrates that the system outperforms the conventional time-based indoor localization schemes without using any tracking technique such as Kalman filters or Bayesian methods.

  11. The use of electrolysis for accurate delta O-17 and delta O-18 isotope measurements in water

    NARCIS (Netherlands)

    Meijer, HAJ; Li, WJ

    1998-01-01

    We present a new system to measure the relative isotopic abundances of both rare isotopes of oxygen in water. Using electrolysis with CuSO4 as electrolyte, water is transformed into oxygen gas. This gas is subsequently analyzed with a standard Isotope Ratio Mass Spectrometer. We investigated the fea

  12. Accurately measuring sea level change from space: an ESA climate change initiative for MSL closure budget studies

    Science.gov (United States)

    Legeais, JeanFrancois; Benveniste, Jérôme

    2016-07-01

    Sea level is a very sensitive index of climate change and variability. Sea level integrates the ocean warming, mountain glaciers and ice sheet melting. Understanding the sea level variability and changes implies an accurate monitoring of the sea level variable at climate scales, in addition to understanding the ocean variability and the exchanges between ocean, land, cryosphere, and atmosphere. That is why Sea Level is one of the Essential Climate Variables (ECV) selected in the frame of the ESA Climate Change Initiative (CCI) program. It aims at providing long-term monitoring of the sea level ECV with regular updates, as required for climate studies. The program is now in its second phase of 3 year (following phase I during 2011-2013). The objectives are firstly to involve the climate research community, to refine their needs and collect their feedbacks on product quality. And secondly to develop, test and select the best algorithms and standards to generate an updated climate time series and to produce and validate the Sea Level ECV product. This will better answer the climate user needs by improving the quality of the Sea Level products and maintain a sustain service for an up-to-date production. This has led to the production of a first version of the Sea Level ECV which has benefited from yearly extensions and now covers the period 1993-2014. Within phase II, new altimeter standards have been developed and tested in order to reprocess the dataset with the best standards for climate studies. The reprocessed ECV will be released in summer 2016. We will present the main achievements of the ESA CCI Sea Level Project. On the one hand, the major steps required to produce the 22 years climate time series are briefly described: collect and refine the user requirements, development of adapted algorithms for climate applications and specification of the production system. On the other hand, the product characteristics are described as well as the results from product

  13. Ability of Functional Independence Measure to accurately predict functional outcome of stroke-specific population: Systematic review

    OpenAIRE

    Madeleine Spencer, DPT, PT; Karen Skop, DPT, PT; Kristina Shesko, DPT, PT; Kristen Nollinger, DPT, PT; Douglas Chumney, DPT, PT; Roberta A. Newton, PT, PhD

    2010-01-01

    Stroke is a leading cause of functional impairments. The ability to quantify the functional ability of poststroke patients engaged in a rehabilitation program may assist in prediction of their functional outcome. The Functional Independence Measure (FIM) is widely used and accepted as a functional-level assessment tool that evaluates the functional status of patients throughout the rehabilitation process. From February to March 2009, we searched MEDLINE, Ovid, CINAHL, and EBSCO for full-text ...

  14. Accurate and precise plasma clearance measurement using four 99mTc-DTPA plasma samples over 4 h

    OpenAIRE

    Wanasundara, Surajith N.; Wesolowski, Michal J.; Barnfield, Mark C.; Waller, Michael L.; Murray, Anthony W.; Burniston, Maria T.; Babyn, Paul S.; Wesolowski, Carl A.

    2015-01-01

    Objectives Glomerular filtration rate can be measured as the plasma clearance (CL) of a glomerular filtration rate marker despite body fluid disturbances using numerous, prolonged time samples. We desire a simplified technique without compromised accuracy and precision. Materials and methods We compared CL values derived from two plasma concentration curve area methods – (a) biexponential fitting [CL (E2)] and (b) Tikhonov adaptively regularized gamma variate fitting [CL (Tk-GV)] – for 4 vers...

  15. Accurate simulation of 802.11 indoor links: a “bursty” channel model based on real measurements

    OpenAIRE

    Luis Muñoz; Ramón Agüero; Marta García-Arranz

    2010-01-01

    We propose a novel channel model to be used for simulating indoor wireless propagation environments. An extensive measurement campaign was carried out to assess the performance of different transport protocols over 802.11 links. This enabled us to better adjust our approach, which is based on an autoregressive filter. One of the main advantages of this proposal lies in its ability to reflect the “bursty” behavior which characterizes indoor wireless scenarios, having a great impact...

  16. How accurately can we measure the hydrogen 2S->1S transition rate from the cosmological data?

    CERN Document Server

    Mukhanov, Viatcheslav; Naselsky, Pavel; Trombetti, Tiziana; Burigana, Carlo

    2012-01-01

    Recent progress in observational cosmology, and especially the forthcoming PLANCK mission data, open new directions in so-called precision cosmology. In this paper we illustrate this statement considering the accuracy of cosmological determination of the two-quanta decay rate of 2s hydrogen atom state. We show that the PLANCK data will allow us to measure this decay rate significantly better than in the laboratory experiments.

  17. An improved approach for accurate and efficient measurement of common carotid artery intima-media thickness in ultrasound images.

    Science.gov (United States)

    Li, Qiang; Zhang, Wei; Guan, Xin; Bai, Yu; Jia, Jing

    2014-01-01

    The intima-media thickness (IMT) of common carotid artery (CCA) can serve as an important indicator for the assessment of cardiovascular diseases (CVDs). In this paper an improved approach for automatic IMT measurement with low complexity and high accuracy is presented. 100 ultrasound images from 100 patients were tested with the proposed approach. The ground truth (GT) of the IMT was manually measured for six times and averaged, while the automatic segmented (AS) IMT was computed by the algorithm proposed in this paper. The mean difference±standard deviation between AS and GT IMT is 0.0231±0.0348 mm, and the correlation coefficient between them is 0.9629. The computational time is 0.3223 s per image with MATLAB under Windows XP on an Intel Core 2 Duo CPU E7500 @2.93 GHz. The proposed algorithm has the potential to achieve real-time measurement under Visual Studio.

  18. An Improved Approach for Accurate and Efficient Measurement of Common Carotid Artery Intima-Media Thickness in Ultrasound Images

    Directory of Open Access Journals (Sweden)

    Qiang Li

    2014-01-01

    Full Text Available The intima-media thickness (IMT of common carotid artery (CCA can serve as an important indicator for the assessment of cardiovascular diseases (CVDs. In this paper an improved approach for automatic IMT measurement with low complexity and high accuracy is presented. 100 ultrasound images from 100 patients were tested with the proposed approach. The ground truth (GT of the IMT was manually measured for six times and averaged, while the automatic segmented (AS IMT was computed by the algorithm proposed in this paper. The mean difference ± standard deviation between AS and GT IMT is 0.0231 ± 0.0348 mm, and the correlation coefficient between them is 0.9629. The computational time is 0.3223 s per image with MATLAB under Windows XP on an Intel Core 2 Duo CPU E7500 @2.93 GHz. The proposed algorithm has the potential to achieve real-time measurement under Visual Studio.

  19. Improving the sampling technique of arterialized capillary samples to obtain more accurate PaO2 measurements.

    Science.gov (United States)

    Wimpress, S; Vara, D D; Brightling, C E

    2005-01-01

    Arterialized earlobe capillary blood samples (ELCS) have been used as a measurement of blood gas status for over 20 years. There is general acceptance that there is a strong correlation and limits of agreement between arterial and arterialized blood samples with respect to pH and PaCO2. Although the correlation between the arterial and arterialized PaO2 is good, the limits of agreement poor. Our aim was to improve the accuracy of this technique in the measurement of PaO2 by simultaneously monitoring the oxygen saturation by pulse oximetry whilst taking an ELCS. We hypothesize that significant discrepancies between the SaO2 and SpO2 highlight either a poorly arterialized sample or an over aerated sample from air bubbles. We compared the SpO2 with the SaO2 of an arterial sample from 27 inpatients. We used the limits of agreement between these samples to define the degree of discordance we would accept between SaO2 and SpO2 before repeat ELCS. Subsequently, 252 consecutive patients attending our respiratory physiology unit over a six-month period had an ELCS and simultaneous SpO2. If there was a discrepancy between SaO2 and SpO2 of > 2% the ELCS was repeated. There was a good correlation and limits of agreement between the SpO2 and arterial SaO2 (r = 0.97, mean difference +/- 95% limits of agreement: 0.34 +/- 2.68). A difference of more than 2% between arterialized SaO2 and SpO2 was identified in 21 patients out of 252 (8.3%) with SaO2 higher in two and lower in 19 (r = 0.96, mean difference +/- 95% limits of agreement: 0.66 +/- 3.1). Repeat ELCS of these 21 samples reduced this discrepancy improving the concordance of the measurements (r = 0.98, mean difference +/- 95% limits of agreement: 0.47 +/- 1.0). In one case a difference of 3% remained between the saturations. We conclude that the addition of simultaneous pulse oximetry with ELCS will identify rogue measurements in about 8% of cases highlighting the need for repeat samples and thus increasing the accuracy of

  20. Accurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10‑6 g m‑2 day‑1 range

    Science.gov (United States)

    Nakano, Yoichiro; Yanase, Takashi; Nagahama, Taro; Yoshida, Hajime; Shimada, Toshihiro

    2016-10-01

    The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10‑6 g m‑2 day‑1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.

  1. Production of extremely low volatile organic compounds from biogenic emissions: Measured yields and atmospheric implications

    Energy Technology Data Exchange (ETDEWEB)

    Jokinen, Tuija; Berndt, Torsten; Makkonen, Risto; Kerminen, Veli-Matti; Junninen, Heikki; Paasonen, Pauli; Stratmann, Frank; Herrmann, Hartmut; Guenther, Alex B.; Worsnop, Douglas R.; Kulmala, M.; Ehn, Mikael K.; Sipila, Mikko

    2015-06-09

    Extremely low volatility organic compounds (ELVOC) are suggested to promote aerosol particle formation and cloud condensation nuclei (CCN) production in the atmosphere. We show that the capability of biogenic VOC (BVOC) to produce ELVOC depends strongly on their chemical structure and relative oxidant levels. BVOC with an endocyclic double bond, representative emissions from, e.g., boreal forests, efficiently produce ELVOC from ozonolysis. Compounds with exocyclic double bonds or acyclic compounds including isoprene, emission representative of the tropics, produce minor quantities of ELVOC, and the role of OH radical oxidation is relatively larger. Implementing these findings into a global modeling framework shows that detailed assessment of ELVOC production pathways is crucial for understanding biogenic secondary organic aerosol and atmospheric CCN formation.

  2. Inference of Extreme Synchrony with an Entropy Measure on a Bipartite Network

    CERN Document Server

    Sato, Aki-Hiro

    2012-01-01

    This article proposes a method to quantify the structure of a bipartite graph with a network entropy from a statistical--physical point of view. The network entropy of a bipartite graph with random links is computed from numerical simulation. As an application of the proposed method to analyze collective behavior, the affairs in which participants quote and trade in the foreign exchange market are quantified. The network entropy per node is found to correspond to the macroeconomic situation. A finite mixture of Gumbel distributions is used to fit with the empirical distribution for the minimum values of network entropy per node in each week. The mixture of Gumbel distributions with parameter estimates by segmentation procedure is verified by Kolmogorov--Smirnov test. The finite mixture of Gumbel distributions can extrapolate the probability of extreme events that have never been observed.

  3. Modeling and measuring the transport and scattering of energetic debris in an extreme ultraviolet plasma source

    Science.gov (United States)

    Sporre, John R.; Elg, Daniel T.; Kalathiparambil, Kishor K.; Ruzic, David N.

    2016-01-01

    A theoretical model for describing the propagation and scattering of energetic species in an extreme ultraviolet (EUV) light lithography source is presented. An EUV light emitting XTREME XTS 13-35 Z-pinch plasma source is modeled with a focus on the effect of chamber pressure and buffer gas mass on energetic ion and neutral debris transport. The interactions of the energetic debris species, which is generated by the EUV light emitting plasma, with the buffer gas and chamber walls are considered as scattering events in the model, and the trajectories of the individual atomic species involved are traced using a Monte Carlo algorithm. This study aims to establish the means by which debris is transported to the intermediate focus with the intent to verify the various mitigation techniques currently employed to increase EUV lithography efficiency. The modeling is compared with an experimental investigation.

  4. Lower-extremity electromyography measures during walking with ankle-destabilization devices.

    Science.gov (United States)

    Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2014-05-01

    Ankle-destabilization devices are rehabilitation tools that may improve neuromuscular control by increasing lower-extremity muscle activation. Their effects should be tested in healthy individuals before being implemented in rehabilitation programs. To compare EMG activation of lower-extremity muscles during walking while wearing 2 different ankle-destabilization devices. Crossover. Laboratory. 15 healthy young adults (5 men, 10 women). Surface EMG activity was recorded from the anterior tibialis, peroneus longus, lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius as subjects walked on a treadmill shod, with an ankle-destabilization boot (ADB), and an ankle-destabilization sandal (ADS). Normalized amplitudes 100 ms before and 200 ms after initial heel contact, time of onset activation relative to initial contact, and percent of activation time across the stride cycle were calculated for each muscle in each condition. The precontact amplitudes of the peroneus longus and lateral gastrocnemius and the postcontact amplitudes of the lateral gastrocnemius were significantly greater in the ADB and ADS conditions. In the ADB condition, the rectus femoris and biceps femoris postcontact amplitudes were significantly greater than shod. The peroneus longus and lateral gastrocnemius were activated significantly earlier, and the anterior tibialis, lateral gastrocnemius, and rectus femoris were activated significantly longer across the stride cycle in the ADB and the ADS conditions. In addition, the peroneus longus was activated significantly longer in the ADB condition when compared with shod. Both ankle-destabilization devices caused an alteration in muscle activity during walking, which may be favorable to an injured patient. Therefore, implementing these devices in rehabilitation programs may be beneficial to improving neuromuscular control.

  5. Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach.

    Science.gov (United States)

    Krishna Kumar, P; Araki, Tadashi; Rajan, Jeny; Saba, Luca; Lavra, Francesco; Ikeda, Nobutaka; Sharma, Aditya M; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R; Gupta, Ajay; Suri, Jasjit S

    2016-12-10

    Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients' left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.

  6. Functional connectivity and structural covariance between regions of interest can be measured more accurately using multivariate distance correlation.

    Science.gov (United States)

    Geerligs, Linda; Cam-Can; Henson, Richard N

    2016-07-15

    Studies of brain-wide functional connectivity or structural covariance typically use measures like the Pearson correlation coefficient, applied to data that have been averaged across voxels within regions of interest (ROIs). However, averaging across voxels may result in biased connectivity estimates when there is inhomogeneity within those ROIs, e.g., sub-regions that exhibit different patterns of functional connectivity or structural covariance. Here, we propose a new measure based on "distance correlation"; a test of multivariate dependence of high dimensional vectors, which allows for both linear and non-linear dependencies. We used simulations to show how distance correlation out-performs Pearson correlation in the face of inhomogeneous ROIs. To evaluate this new measure on real data, we use resting-state fMRI scans and T1 structural scans from 2 sessions on each of 214 participants from the Cambridge Centre for Ageing & Neuroscience (Cam-CAN) project. Pearson correlation and distance correlation showed similar average connectivity patterns, for both functional connectivity and structural covariance. Nevertheless, distance correlation was shown to be 1) more reliable across sessions, 2) more similar across participants, and 3) more robust to different sets of ROIs. Moreover, we found that the similarity between functional connectivity and structural covariance estimates was higher for distance correlation compared to Pearson correlation. We also explored the relative effects of different preprocessing options and motion artefacts on functional connectivity. Because distance correlation is easy to implement and fast to compute, it is a promising alternative to Pearson correlations for investigating ROI-based brain-wide connectivity patterns, for functional as well as structural data.

  7. A study of accurate latent heat measurement for a PCM with a low melting temperature using T-history method

    Energy Technology Data Exchange (ETDEWEB)

    Peck, Jong Hyeon [Korea Institute of Industrial Technology (KITECH), Energy System Team, 35-3 Ipjang-myeon, Chonan 330-820 (Korea, Republic of); Kim, Jae-Jun [College of Architecture, Hanyang University, Seoul 133-791 (Korea, Republic of); Kang, Chaedong [Department of Mechanical Engineering, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Hong, Hiki [School of Mechanical and Industrial System Engineering, KyungHee University, Yongin 449-701 (Korea, Republic of)

    2006-11-15

    When the latent heat of a phase change material (PCM) with a lower melting point than ambient temperature was assessed according to the standard T-history method using a vertically oriented test tube, a temperature gradient occurred in the longitudinal direction of the tube due to natural convection. This led to a decrease in the accuracy of the latent heat of fusion measurement. In this study, the accuracy of the measurement with the original T-history method was improved without decreasing the test's simplicity and convenience by setting the test tube horizontally. The heat transfer to the vapor-layer of the tube under volume change during melting was assumed to be negligible and the results were calculated using the two inflection points of temperature as the start and end of latent heat period. Under these assumptions, the results agree closely with other reference data. And, the new method proposed in this study showed a remarkable reduction in data scattering. (author)

  8. ‘Dose-to-Mother’ Deuterium Oxide Dilution Technique: An Accurate Strategy to Measure Vitamin A Intake in Breastfed Infants

    Directory of Open Access Journals (Sweden)

    Veronica Lopez-Teros

    2017-02-01

    Full Text Available In Mexico, infants (0–2 years old show the highest prevalence of vitamin A deficiency (VAD, measured by serum retinol concentrations. Thus, we consider that low vitamin A (VA intake through breast milk (BM combined with poor weaning practices are the main factors that contribute to VAD in this group. We combined the assessment of VA status in lactating women using BM retinol and a stable isotope ‘dose-to-mother’ technique to measure BM production in women from urban and agricultural areas. Infants’ mean BM intake was 758 ± 185 mL, and no difference was observed between both areas (p = 0.067. Mean BM retinol concentration was 1.09 μmol/L, which was significantly lower for the agricultural area (p = 0.028. Based on BM retinol concentration, 57% of women were VAD; although this prevalence fell to 16% when based on fat content. Regardless of the VA biomarker used here, infants from the urban and agricultural areas cover only 66% and 49% of their dietary adequate intake from BM, respectively (p = 0.054. Our data indicate that VAD is still a public health concern in Mexico. Adopting both methods to assess VA transfer from the mother to the breastfed child offers an innovative approach towards the nutritional assessment of vulnerable groups.

  9. How accurate are interpretations of curriculum-based measurement progress monitoring data? Visual analysis versus decision rules.

    Science.gov (United States)

    Van Norman, Ethan R; Christ, Theodore J

    2016-10-01

    Curriculum based measurement of oral reading (CBM-R) is used to monitor the effects of academic interventions for individual students. Decisions to continue, modify, or terminate these interventions are made by interpreting time series CBM-R data. Such interpretation is founded upon visual analysis or the application of decision rules. The purpose of this study was to compare the accuracy of visual analysis and decision rules. Visual analysts interpreted 108 CBM-R progress monitoring graphs one of three ways: (a) without graphic aids, (b) with a goal line, or (c) with a goal line and a trend line. Graphs differed along three dimensions, including trend magnitude, variability of observations, and duration of data collection. Automated trend line and data point decision rules were also applied to each graph. Inferential analyses permitted the estimation of the probability of a correct decision (i.e., the student is improving - continue the intervention, or the student is not improving - discontinue the intervention) for each evaluation method as a function of trend magnitude, variability of observations, and duration of data collection. All evaluation methods performed better when students made adequate progress. Visual analysis and decision rules performed similarly when observations were less variable. Results suggest that educators should collect data for more than six weeks, take steps to control measurement error, and visually analyze graphs when data are variable. Implications for practice and research are discussed.

  10. The ratio of glycated albumin to hemoglobin A1c measured in IFCC units accurately represents the glycation gap.

    Science.gov (United States)

    Akatsuka, Junya; Mochizuki, Mie; Musha, Ikuma; Ohtake, Akira; Kobayashi, Kisho; Kikuchi, Toru; Kikuchi, Nobuyuki; Kawamura, Tomoyuki; Urakami, Tatsuhiko; Sugihara, Shigetaka; Hoshino, Tadao; Amemiya, Shin

    2015-01-01

    The glycation gap (G-gap: difference between measured hemoglobin A1c [A1C] and the value predicted by its regression on the fructosamine level) is stable and associated with diabetic complications. Measuring A1C level in International Federation of Clinical Chemistry (IFCC) units (A1C-SI; mmol/mol) and National Glycohemoglobin Standardization Program units (A1C-NGSP; %) and using glycated albumin (GA) level instead of fructosamine level for calculating the G-gap, we investigated whether the G-gap is better represented by GA/A1C ratio if expressed in SI units (GA/A1C-SI ratio) rather than in NGSP units (GA/A1C-% ratio). We examined 749 Japanese children with type 1 diabetes using simultaneous GA and A1C measurements. Of these, 369 patients were examined more than five times to assess the consistency of the G-gap and the GA/A1C ratio within individuals. The relationship of GA/A1C-% ratio to the corresponding A1C-NGSP was stronger than that of GA/A1C-SI ratio to A1C-IFCC. At enrollment, the inverse relationship between the GA/A1C-SI ratio and G-gap was highly significant (R(2) = 0.95) compared with that between the GA/A1C-% ratio and G-gap (R(2) = 0.69). A highly significant inverse relationship was also observed between the mean GA/A1C-SI ratio and the mean G-gaps obtained individually over time (R(2) = 0.95) compared with that using the corresponding A1C-NGSP (R(2) = 0.67). We conclude that the G-gap is better represented by the GA/A1C-SI ratio. We propose the use of mean GA/A1C-SI ratios easily obtained individually over time as reference values in Japanese children with type 1 diabetes (6.75 ± 0.60 [means ± SD]).

  11. A 3D assessment tool for accurate volume measurement for monitoring the evolution of cutaneous leishmaniasis wounds.

    Science.gov (United States)

    Zvietcovich, Fernando; Castañeda, Benjamin; Valencia, Braulio; Llanos-Cuentas, Alejandro

    2012-01-01

    Clinical assessment and outcome metrics are serious weaknesses identified on the systematic reviews of cutaneous Leishmaniasis wounds. Methods with high accuracy and low-variability are required to standarize study outcomes in clinical trials. This work presents a precise, complete and noncontact 3D assessment tool for monitoring the evolution of cutaneous Leishmaniasis (CL) wounds based on a 3D laser scanner and computer vision algorithms. A 3D mesh of the wound is obtained by a commercial 3D laser scanner. Then, a semi-automatic segmentation using active contours is performed to separate the ulcer from the healthy skin. Finally, metrics of volume, area, perimeter and depth are obtained from the mesh. Traditional manual 3D and 3D measurements are obtained as a gold standard. Experiments applied to phantoms and real CL wounds suggest that the proposed 3D assessment tool provides higher accuracy (error 3D assessment tool provides high accuracy metrics which deserve more formal prospective study.

  12. Accurate kinematic measurement at interfaces between dissimilar materials using conforming finite-element-based digital image correlation

    KAUST Repository

    Tao, Ran

    2016-02-11

    Digital image correlation (DIC) is now an extensively applied full-field measurement technique with subpixel accuracy. A systematic drawback of this technique, however, is the smoothening of the kinematic field (e.g., displacement and strains) across interfaces between dissimilar materials, where the deformation gradient is known to be large. This can become an issue when a high level of accuracy is needed, for example, in the interfacial region of composites or joints. In this work, we described the application of global conforming finite-element-based DIC technique to obtain precise kinematic fields at interfaces between dissimilar materials. Speckle images from both numerical and actual experiments processed by the described global DIC technique better captured sharp strain gradient at the interface than local subset-based DIC. © 2016 Elsevier Ltd. All rights reserved.

  13. Does Pelletizing Catalysts Influence the Efficiency Number of Activity Measurements? Spectrochemical Engineering Considerations for an Accurate Operando Study

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Perez-Ferreras, Susana; Banares, Miguel A.

    2013-01-01

    of, for example, support oxides might take place, which in turn affects the pore size distribution and the porosity of the catalyst, leading to the observation of lower activity values due to decreased catalyst efficiency. This phenomenon can also apply to conventional activity measurements......, in the cases that pelletizing and recrushing of samples are performed to obtain adequate particle size fractions for the catalytic bed. A case study of an operand investigation of a V2O3-WO3/TiO2-sepiolite catalyst is used as an example, and simple calculations of the influence of catalyst activity...... and internal pore diffusion properties are considered in this paper for the evaluation of catalyst performance in, for example, operando reactors. Thus, it is demonstrated that with a pelletizing pressure of...

  14. A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

    Energy Technology Data Exchange (ETDEWEB)

    Gyüre, B.; Márkus, B. G.; Bernáth, B.; Simon, F., E-mail: ferenc.simon@univie.ac.at [Department of Physics, Budapest University of Technology and Economics and MTA-BME Lendület Spintronics Research Group (PROSPIN), P.O. Box 91, H-1521 Budapest (Hungary); Murányi, F. [Foundation for Research on Information Technologies in Society (IT’IS), Zeughausstrasse 43, 8004 Zurich (Switzerland)

    2015-09-15

    We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is pumped with the microwave radiation at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emitted microwave signal is down-converted with a microwave mixer, digitized, and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being a FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method has similar accuracy to the existing ones, which are based on sweeping or modulating the frequency of the microwave radiation.

  15. Development of an accurate pH measurement methodology for the pore fluids of low pH cementitious materials

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, M. C.; Garcia Calvo, J. L. [The Spanish National Research Council (CSIC), Madrid (Spain); Walker, C. [Japan Atomic Energy Agency (JAEA), Ibaraki (Japan)] [and others

    2012-08-15

    The main objective of this project has been the development of an agreed set of protocols for the pH measurement of the pore fluid of a low pH cementitious material. Three protocols have been developed (Chapter 2), a reference method, based on pore fluid expression (PFE), and two routine methods with and without filtering, based on Ex Situ Leaching (ESL) procedures. Templates have been designed on which to record details of the pH measurement for the reference (PFE) method (Appendix C) and the routine (ESL) methods without and with filtering (Appendix D). Preliminary protocols were based on a broad review of the literature (Appendix A) and refined through a series of test experiments of the more critical parameters (Appendix B). After definition of the preliminary protocols, two phases of interlaboratory tests were performed. The first phase (Chapter 3) used the same low pH cement paste and enabled the nine participating laboratories to use, become familiar with and to identify any problems/uncertainties in the preliminary protocols. The reported pH values were subjected to a statistical analysis of the (within laboratory) repeatability and (between-laboratory) reproducibility and so provided a reliability test of the preliminary protocols. The second phase (Chapter 4) of interlaboratory tests used four different candidate low pH cementitious materials in the same nine laboratories, which allowed testing, validation and comparison of the reported pH values, which were obtained using the final protocols for the reference (PFE) and routine (ESL) methods by statistical analysis. The proposed final protocols (Chapter 2) have resulted in the reported pH values having low deviation and high reproducibility and repeatability. This will allow confidence in the pH value when selecting a candidate low pH cementitious material to be used in the engineered component of a high-level nuclear waste repository.

  16. Accurate Measurements of the Skin Surface Area of the Healthy Auricle and Skin Deficiency in Microtia Patients

    Science.gov (United States)

    van Doremalen, Rob F. M.; Melchels, Ferry P. W.; Kolodzynski, Michail N.; Pouran, Behdad; Malda, Jos; Kon, Moshe; Breugem, Corstiaan C.

    2016-01-01

    Background: The limited cranial skin covering auricular implants is an important yet underrated factor in auricular reconstruction for both reconstruction surgery and tissue engineering strategies. We report exact measurements on skin deficiency in microtia patients and propose an accessible preoperative method for these measurements. Methods: Plaster ear models (n = 11; male:female = 2:1) of lobular-type microtia patients admitted to the University Medical Center Utrecht in The Netherlands were scanned using a micro-computed tomographic scanner or a cone-beam computed tomographic scanner. The resulting images were converted into mesh models from which the surface area could be calculated. Results: The mean total skin area of an adult-size healthy ear was 47.3 cm2, with 49.0 cm2 in men and 44.3 cm2 in women. Microtia ears averaged 14.5 cm2, with 15.6 cm2 in men and 12.6 cm2 in women. The amount of skin deficiency was 25.4 cm2, with 26.7 cm2 in men and 23.1 cm2 in women. Conclusions: This study proposes a novel method to provide quantitative data on the skin surface area of the healthy adult auricle and the amount of skin deficiency in microtia patients. We demonstrate that the microtia ear has less than 50% of skin available compared with healthy ears. Limited skin availability in microtia patients can lead to healing problems after auricular reconstruction and poses a significant challenge in the development of tissue-engineered cartilage implants. The results of this study could be used to evaluate outcomes and investigate new techniques with regard to tissue-engineered auricular constructs. PMID:28293505

  17. Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    Directory of Open Access Journals (Sweden)

    Jørgensen Jesper

    2008-10-01

    Full Text Available Abstract Background In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evaluated the accuracy of tumor volume determined from 18F-fluorodeoxyglucose (18F-FDG PET. Methods Subcutaneously implanted human breast adenocarcinoma cells in NMRI nude mice served as tumor model. Tumor volume (n = 20 was determined in vivo by external caliper, microCT and 18F-FDG-PET and subsequently reference volume was determined ex vivo. Intra-observer reproducibility of the microCT and caliper methods were determined by acquiring 10 repeated volume measurements. Volumes of a group of tumors (n = 10 were determined independently by two observers to assess inter-observer variation. Results Tumor volume measured by microCT, PET and caliper all correlated with reference volume. No significant bias of microCT measurements compared with the reference was found, whereas both PET and caliper had systematic bias compared to reference volume. Coefficients of variation for intra-observer variation were 7% and 14% for microCT and caliper measurements, respectively. Regression coefficients between observers were 0.97 for microCT and 0.91 for caliper measurements. Conclusion MicroCT was more accurate than both caliper and 18F-FDG-PET for in vivo volumetric measurements of subcutaneous tumors in mice.18F-FDG-PET was considered unsuitable for determination of tumor size. External caliper were inaccurate and encumbered with a significant and size dependent bias. MicroCT was also the most reproducible of the methods.

  18. The mis-measurement of extreme global poverty: A case study in the Pacific Islands.

    Science.gov (United States)

    Deeming, Christopher; Gubhaju, Bina

    2015-09-01

    Debate over the measurement of global poverty in low- and middle-income countries continues unabated. There is considerable controversy surrounding the 'dollar a day' measure used to monitor progress against the Millennium Development Goals. This article shines fresh light on the debate with new empirical analyses of poverty (including child poverty), inequality and deprivation levels in the Pacific island state of Vanuatu. The study focuses not only on economic and monetary metrics and measures, but also the measures of deprivation derived from sociology in relation to shelter, sanitation, water, information, nutrition, health and education. Until recently, there had been few, if any, attempts to study poverty and deprivation disparities among children in this part of the world. Different measures yield strikingly different estimates of poverty. The article, therefore, attempts to situate the study findings in the broader international context of poverty measurement and discusses their implications for future research and the post-2015 development agenda.

  19. How many measurements are needed to estimate accurate daily and annual soil respiration fluxes? Analysis using data from a temperate rainforest

    Science.gov (United States)

    Perez-Quezada, Jorge F.; Brito, Carla E.; Cabezas, Julián; Galleguillos, Mauricio; Fuentes, Juan P.; Bown, Horacio E.; Franck, Nicolás

    2016-12-01

    Making accurate estimations of daily and annual Rs fluxes is key for understanding the carbon cycle process and projecting effects of climate change. In this study we used high-frequency sampling (24 measurements per day) of Rs in a temperate rainforest during 1 year, with the objective of answering the questions of when and how often measurements should be made to obtain accurate estimations of daily and annual Rs. We randomly selected data to simulate samplings of 1, 2, 4 or 6 measurements per day (distributed either during the whole day or only during daytime), combined with 4, 6, 12, 26 or 52 measurements per year. Based on the comparison of partial-data series with the full-data series, we estimated the performance of different partial sampling strategies based on bias, precision and accuracy. In the case of annual Rs estimation, we compared the performance of interpolation vs. using non-linear modelling based on soil temperature. The results show that, under our study conditions, sampling twice a day was enough to accurately estimate daily Rs (RMSE < 10 % of average daily flux), even if both measurements were done during daytime. The highest reduction in RMSE for the estimation of annual Rs was achieved when increasing from four to six measurements per year, but reductions were still relevant when further increasing the frequency of sampling. We found that increasing the number of field campaigns was more effective than increasing the number of measurements per day, provided a minimum of two measurements per day was used. Including night-time measurements significantly reduced the bias and was relevant in reducing the number of field campaigns when a lower level of acceptable error (RMSE < 5 %) was established. Using non-linear modelling instead of linear interpolation did improve the estimation of annual Rs, but not as expected. In conclusion, given that most of the studies of Rs use manual sampling techniques and apply only one measurement per day, we

  20. Measurement of pelvic motion is a prerequisite for accurate estimation of hip joint work in maximum height squat jumping.

    Science.gov (United States)

    Blache, Yoann; Bobbert, Maarten; Argaud, Sebastien; Pairot de Fontenay, Benoit; Monteil, Karine M

    2013-08-01

    In experiments investigating vertical squat jumping, the HAT segment is typically defined as a line drawn from the hip to some point proximally on the upper body (eg, the neck, the acromion), and the hip joint as the angle between this line and the upper legs (θUL-HAT). In reality, the hip joint is the angle between the pelvis and the upper legs (θUL-pelvis). This study aimed to estimate to what extent hip joint definition affects hip joint work in maximal squat jumping. Moreover, the initial pelvic tilt was manipulated to maximize the difference in hip joint work as a function of hip joint definition. Twenty-two male athletes performed maximum effort squat jumps in three different initial pelvic tilt conditions: backward (pelvisB), neutral (pelvisN), and forward (pelvisF). Hip joint work was calculated by integrating the hip net joint torque with respect to θUL-HAT (WUL-HAT) or with respect to θUL-pelvis (WUL-pelvis). θUL-HAT was greater than θUL-pelvis in all conditions. WUL-HAT overestimated WULpelvis by 33%, 39%, and 49% in conditions pelvisF, pelvisN, and pelvisB, respectively. It was concluded that θUL-pelvis should be measured when the mechanical output of hip extensor muscles is estimated.

  1. Rapid jetting status inspection and accurate droplet volume measurement for a piezo drop-on-demand inkjet print head using a scanning mirror for display applications

    Science.gov (United States)

    Shin, Dong-Youn; Kim, Minsung

    2017-02-01

    Despite the inherent fabrication simplicity of piezo drop-on-demand inkjet printing, the non-uniform deposition of colourants or electroluminescent organic materials leads to faulty display products, and hence, the importance of rapid jetting status inspection and accurate droplet volume measurement increases from a process perspective. In this work, various jetting status inspections and droplet volume measurement methods are reviewed by discussing their advantages and disadvantages, and then, the opportunities for the developed prototype with a scanning mirror are explored. This work demonstrates that jetting status inspection of 384 fictitious droplets can be performed within 17 s with maximum and minimum measurement accuracies of 0.2 ± 0.5 μ m for the fictitious droplets of 50 μ m in diameter and -1.2 ± 0.3 μ m for the fictitious droplets of 30 μ m in diameter, respectively. In addition to the new design of an inkjet monitoring instrument with a scanning mirror, two novel methods to accurately measure the droplet volume by amplifying a minute droplet volume difference and then converting to other physical properties are suggested and the droplet volume difference of ±0.3% is demonstrated to be discernible using numerical simulations, even with the low measurement accuracy of 1 μ m . When the fact is considered that the conventional vision-based method with a CCD camera requires the optical measurement accuracy less than 25 nm to measure the volume of an in-flight droplet in the nominal diameter of 50 μ m at the same volume measurement accuracy, the suggested method with the developed prototype offers a whole new opportunity to inkjet printing for display applications.

  2. How extreme are extremes?

    Science.gov (United States)

    Cucchi, Marco; Petitta, Marcello; Calmanti, Sandro

    2016-04-01

    High temperatures have an impact on the energy balance of any living organism and on the operational capabilities of critical infrastructures. Heat-wave indicators have been mainly developed with the aim of capturing the potential impacts on specific sectors (agriculture, health, wildfires, transport, power generation and distribution). However, the ability to capture the occurrence of extreme temperature events is an essential property of a multi-hazard extreme climate indicator. Aim of this study is to develop a standardized heat-wave indicator, that can be combined with other indices in order to describe multiple hazards in a single indicator. The proposed approach can be used in order to have a quantified indicator of the strenght of a certain extreme. As a matter of fact, extremes are usually distributed in exponential or exponential-exponential functions and it is difficult to quickly asses how strong was an extreme events considering only its magnitude. The proposed approach simplify the quantitative and qualitative communication of extreme magnitude

  3. Simple and accurate measurement of carbamazepine in surface water by use of porous membrane-protected micro-solid-phase extraction coupled with isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Hui Ling [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); Wong, Lingkai [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Liu, Qinde, E-mail: liu_qinde@hsa.gov.sg [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Teo, Tang Lin; Lee, Tong Kooi [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Lee, Hian Kee, E-mail: chmleehk@nus.edu.sg [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore)

    2016-03-17

    To achieve fast and accurate analysis of carbamazepine in surface water, we developed a novel porous membrane-protected micro-solid-phase extraction (μ-SPE) method, followed by liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) analysis. The μ-SPE device (∼0.8 × 1 cm) was fabricated by heat-sealing edges of a polypropylene membrane sheet to devise a bag enclosing the sorbent. The analytes (both carbamazepine and isotope-labelled carbamazepine) were first extracted by μ-SPE device in the sample (10 mL) via agitation, then desorbed in an organic solvent (1 mL) via ultrasonication. Several parameters such as organic solvent for pre-conditioning of μ-SPE device, amount of sorbent, adsorption time, and desorption solvent and time were investigated to optimize the μ-SPE efficiency. The optimized method has limits of detection and quantitation estimated to be 0.5 ng L{sup −1} and 1.6 ng L{sup −1}, respectively. Surface water samples spiked with different amounts of carbamazepine (close to 20, 500, and 1600 ng L{sup −1}, respectively) were analysed for the validation of method precision and accuracy. Good precision was obtained as demonstrated by relative standard deviations of 0.7% for the samples with concentrations of 500 and 1600 ng kg{sup −1}, and 5.8% for the sample with concentration of 20 ng kg{sup −1}. Good accuracy was also demonstrated by the relative recoveries in the range of 96.7%–103.5% for all samples with uncertainties of 1.1%–5.4%. Owing to the same chemical properties of carbamazepine and isotope-labelled carbamazepine, the isotope ratio in the μ-SPE procedure was accurately controlled. The use of μ-SPE coupled with IDMS analysis significantly facilitated the fast and accurate measurement of carbamazepine in surface water. - Highlights: • μ-SPE coupled with IDMS for the measurement of carbamazepine. • The method is the first report of coupling μ-SPE with IDMS. • μ-SPE is fast, time

  4. Does objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis.

    Science.gov (United States)

    Hockey, C A; van Zundert, A A J; Paratz, J D

    2016-09-01

    Correct inflation pressures of the tracheal cuff are recommended to ensure adequate ventilation and prevent aspiration and adverse events. However there are conflicting views on which measurement to employ. The aim of this review was to examine whether adjustment of cuff pressure guided by objective measurement, compared with subjective measurement or observation of the pressure value alone, was able to prevent patient-related adverse effects and maintain accurate cuff pressures. A search of PubMed, Web of Science, Embase, CINAHL and ScienceDirect was conducted using keywords 'cuff pressure' and 'measure*' and related synonyms. Included studies were randomised or pseudo-randomised controlled trials investigating mechanically ventilated patients both in the intensive care unit and during surgery. Outcomes included adverse effects and the comparison of pressure measurements. Pooled analyses were performed to calculate risk ratios, effect sizes and 95% confidence intervals. Meta-analysis found preliminary evidence that adjustment of cuff pressure guided by objective measurement as compared with subjective measurement or observation of the pressure value alone, has benefit in preventing adverse effects. These included cough at two hours (odds ratio [OR] 0.42, confidence interval [CI] 0.23 to 0.79, P=0.007), hoarseness at 24 hours (OR 0.49, CI 0.31 to 0.76, P measurement to guide adjustment or observation of the pressure value alone may lead to patient-related adverse effects and inaccuracies. It is recommended that an objective form of measurement be used.

  5. In situ measurements reveal extremely low pH in soil

    DEFF Research Database (Denmark)

    Nielsen, Knud Erik; Nielsen, Lars Peter; Damgaard, Christian Frølund

    2017-01-01

    We measured pH in situ in the top organic soil horizons in heathland and pine forest and found values between 2.6 and 3.2. This was 0.5e0.8 units lower than concurrent laboratory pH measurements of the same soil, which raises questions about the interpretation of pH measurements. We propose...... that the higher pH recorded by standard laboratory methods may be due to buffering ions from soil biota released from drying, grinding and rewetting of soil samples, whereas the in situ pH reflects the correct level of acidification....

  6. Accurate measurement of heteronuclear dipolar couplings by phase-alternating R-symmetry (PARS) sequences in magic angle spinning NMR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Guangjin, E-mail: hou@udel.edu, E-mail: tpolenov@udel.edu; Lu, Xingyu, E-mail: luxingyu@udel.edu, E-mail: lexvega@comcast.net; Vega, Alexander J., E-mail: luxingyu@udel.edu, E-mail: lexvega@comcast.net; Polenova, Tatyana, E-mail: hou@udel.edu, E-mail: tpolenov@udel.edu [Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, USA and Pittsburgh Center for HIV Protein Interactions, University of Pittsburgh School of Medicine, 1051 Biomedical Science Tower 3, 3501 Fifth Ave., Pittsburgh, Pennsylvania 15261 (United States)

    2014-09-14

    We report a Phase-Alternating R-Symmetry (PARS) dipolar recoupling scheme for accurate measurement of heteronuclear {sup 1}H-X (X = {sup 13}C, {sup 15}N, {sup 31}P, etc.) dipolar couplings in MAS NMR experiments. It is an improvement of conventional C- and R-symmetry type DIPSHIFT experiments where, in addition to the dipolar interaction, the {sup 1}H CSA interaction persists and thereby introduces considerable errors in the dipolar measurements. In PARS, phase-shifted RN symmetry pulse blocks applied on the {sup 1}H spins combined with π pulses applied on the X spins at the end of each RN block efficiently suppress the effect from {sup 1}H chemical shift anisotropy, while keeping the {sup 1}H-X dipolar couplings intact. Another advantage over conventional DIPSHIFT experiments, which require the signal to be detected in the form of a reduced-intensity Hahn echo, is that the series of π pulses refocuses the X chemical shift and avoids the necessity of echo formation. PARS permits determination of accurate dipolar couplings in a single experiment; it is suitable for a wide range of MAS conditions including both slow and fast MAS frequencies; and it assures dipolar truncation from the remote protons. The performance of PARS is tested on two model systems, [{sup 15}N]-N-acetyl-valine and [U-{sup 13}C,{sup 15}N]-N-formyl-Met-Leu-Phe tripeptide. The application of PARS for site-resolved measurement of accurate {sup 1}H-{sup 15}N dipolar couplings in the context of 3D experiments is presented on U-{sup 13}C,{sup 15}N-enriched dynein light chain protein LC8.

  7. Accurate measurement of heteronuclear dipolar couplings by phase-alternating R-symmetry (PARS) sequences in magic angle spinning NMR spectroscopy.

    Science.gov (United States)

    Hou, Guangjin; Lu, Xingyu; Vega, Alexander J; Polenova, Tatyana

    2014-09-14

    We report a Phase-Alternating R-Symmetry (PARS) dipolar recoupling scheme for accurate measurement of heteronuclear (1)H-X (X = (13)C, (15)N, (31)P, etc.) dipolar couplings in MAS NMR experiments. It is an improvement of conventional C- and R-symmetry type DIPSHIFT experiments where, in addition to the dipolar interaction, the (1)H CSA interaction persists and thereby introduces considerable errors in the dipolar measurements. In PARS, phase-shifted RN symmetry pulse blocks applied on the (1)H spins combined with π pulses applied on the X spins at the end of each RN block efficiently suppress the effect from (1)H chemical shift anisotropy, while keeping the (1)H-X dipolar couplings intact. Another advantage over conventional DIPSHIFT experiments, which require the signal to be detected in the form of a reduced-intensity Hahn echo, is that the series of π pulses refocuses the X chemical shift and avoids the necessity of echo formation. PARS permits determination of accurate dipolar couplings in a single experiment; it is suitable for a wide range of MAS conditions including both slow and fast MAS frequencies; and it assures dipolar truncation from the remote protons. The performance of PARS is tested on two model systems, [(15)N]-N-acetyl-valine and [U-(13)C,(15)N]-N-formyl-Met-Leu-Phe tripeptide. The application of PARS for site-resolved measurement of accurate (1)H-(15)N dipolar couplings in the context of 3D experiments is presented on U-(13)C,(15)N-enriched dynein light chain protein LC8.

  8. Atomic spectroscopy and highly accurate measurement: determination of fundamental constants; Spectroscopie atomique et mesures de grande precision: determination de constantes fonfamentales

    Energy Technology Data Exchange (ETDEWEB)

    Schwob, C

    2006-12-15

    This document reviews the theoretical and experimental achievements of the author concerning highly accurate atomic spectroscopy applied for the determination of fundamental constants. A pure optical frequency measurement of the 2S-12D 2-photon transitions in atomic hydrogen and deuterium has been performed. The experimental setting-up is described as well as the data analysis. Optimized values for the Rydberg constant and Lamb shifts have been deduced (R = 109737.31568516 (84) cm{sup -1}). An experiment devoted to the determination of the fine structure constant with an aimed relative uncertainty of 10{sup -9} began in 1999. This experiment is based on the fact that Bloch oscillations in a frequency chirped optical lattice are a powerful tool to transfer coherently many photon momenta to the atoms. We have used this method to measure accurately the ratio h/m(Rb). The measured value of the fine structure constant is {alpha}{sub -1} = 137.03599884 (91) with a relative uncertainty of 6.7*10{sup -9}. The future and perspectives of this experiment are presented. This document presented before an academic board will allow his author to manage research work and particularly to tutor thesis students. (A.C.)

  9. Electromagnetic calorimeter and accurate measurement with the ATLAS detector of the LHC collider; Calorimetrie electromagnetique et mesures de precision avec le detecteur ATLAS aupres du collisionneur LHC

    Energy Technology Data Exchange (ETDEWEB)

    Pralavorio, P

    2007-06-15

    The main purpose of the ATLAS experiment is the understanding of the underlying mechanisms that drive the breaking of the electro-weak symmetry through the discovery of Higgs bosons. An important element to achieve this aim was the design of an electromagnetic calorimeter able to investigate the decay channels: H {yields} {gamma}{gamma} and H {yields} 4e. The high performance of the calorimeter will allow us to get a better accuracy on the measuring values of W and top masses which is essential to indirectly constrain the mass of the Higgs. In the same way, accurate measurements of top and W properties during the decays of top and tWb vertex will be necessary to question the standard model and to see beyond. The author has been working for 9 years in the ATLAS project, he has been involved in the design, construction, qualification and testing phases of the electromagnetic calorimeter of ATLAS. This document is a detailed presentation of the calorimeter, of its qualification and of its expectations when LHC is operating. This document is organized into 4 chapters: 1) assets and weaknesses of the standard model, 2) the ATLAS experiment, 3) the electromagnetic calorimeter, and 4) accurate measurements with ATLAS. This document presented before an academic board will allow its author to manage research works and particularly to tutor thesis students. (A.C.)

  10. Accurate measurements of fission-fragment yields in 234,235,236,238U(γ,f with the SOFIA set-up

    Directory of Open Access Journals (Sweden)

    Chatillon A.

    2016-01-01

    Full Text Available SOFIA (Studies On Fission with Aladin is a new experimental set-up dedicated to accurate measurement of fission-fragments isotopic yields. It is located at GSI, the only place to use inverse kinematics at relativistic energies in order to study the (γ,f electromagnetic-induced fission. The SOFIA set-up is a large-acceptance magnetic spectrometer, which allows to fully identify both fission fragments in coincidence on the whole fission-fragment range. This paper will report on fission yields obtained in 234,235,236,238U(γ,f reactions.

  11. Embedded optical probes for simultaneous pressure and temperature measurement of materials in extreme conditions

    Science.gov (United States)

    Sandberg, R. L.; Rodriguez, G.; Gibson, L. L.; Dattelbaum, D. M.; Stevens, G. D.; Grover, M.; Lalone, B. M.; Udd, E.

    2014-05-01

    We present recent efforts at Los Alamos National Laboratory (LANL) to develop sensors for simultaneous, in situ pressure and temperature measurements under dynamic conditions by using an all-optical fiber-based approach. While similar tests have been done previously in deflagration-to-detonation tests (DDT), where pressure and temperature were measured to 82 kbar and 400°C simultaneously, here we demonstrate the use of embedded fiber grating sensors to obtain high temporal resolution, in situ pressure measurements in inert materials. We present two experimental demonstrations of pressure measurements: (1) under precise shock loading from a gas-gun driven plate impact and (2) under high explosive driven shock in a water filled vessel. The system capitalizes on existing telecom components and fast transient digitizing recording technology. It operates as a relatively inexpensive embedded probe (single-mode 1550 nm fiber-based Bragg grating) that provides a continuous fast pressure record during shock and/or detonation. By applying well-controlled shock wave pressure profiles to these inert materials, we study the dynamic pressure response of embedded fiber Bragg gratings to extract pressure amplitude of the shock wave and compare our results with particle velocity wave profiles measured simultaneously.

  12. First results of measurements of extreme ultraviolet radiation onboard a geostationary satellite "ELECTRO-L"

    Science.gov (United States)

    Nusinov, Anatoliy; Kazachevskaya, Tamara; Gonjukh, David

    Measurements of the intensity of EUV emission in the hydrogen Lyman-alpha line were conducted by a broadband photometer VUSS-E onboard geostationary Hydrometeorological satellite "Electro" since March 2011. The solar hydrogen Lyman-alpha line (lambda = 121.6 nm) was monitored. The photomultiplier with LiF window used as a detector insensitive to visible light. Long-wavelength limit of the spectral band sensitivity of the instrument is about 200 nm, so the signal of the device is defined as the flux of solar radiation in the region of 123-200 nm. Its exclusion was carried out by calculation. Since the satellite "Electro" designed for remote sensing of the Earth, its line of sight focused on Earth. Alignment of instrument in the Sun direction was achieved by installing it on the solar panel, periodically moved in the solar direction. Correction of instrument readings, reduced due to the deviation of its axis from the Sun direction, carried out by calculation. Measurements were carried out every second. The first results of the measurements are presented. The difference in absolute calibration Electro-L/VUSS-E is within 5% of corresponding values for measurements TIMED satellite in those days, that is in agreement with laboratory calibrations. It is useful to measure the temperature of the instrument, as its variation on a small interval of time makes change the value of the output signal about 1-2 %. During first year of operation, the sensitivity of the apparatus remained within ± 2% of measured value, significant degradation of sensitivity was not observed. Over time of observation there have been several large flares of X class. The increase of the signal in the ultraviolet range does not exceed a few percent during these flares.

  13. The Poverty Burden: A Measure of the Difficulty of Ending Extreme Poverty

    OpenAIRE

    John Quiggin; Renuka Mahadevan

    2010-01-01

    In this paper, we consider an extension of the commonly used poverty gap measure that may be used to address the question of whether the elimination of poverty is a feasible objective, given sufficient political commitment. The resources potentially available to address poverty may be measured by the total amount by which the incomes of the non-poor exceed the same poverty line. The ratio of the poverty gap to the resources potentially available is equal to the proportional tax rate on income...

  14. Extreme group index measured and calculated in 2D SOI-based photonic crystal waveguides

    DEFF Research Database (Denmark)

    Lavrinenko, Andrei; Jacobsen, Rune Shim; Fage-Pedersen, Jacob;

    2005-01-01

    lattice of air-holes in the 216-nm thick silicon layer in an SOI material. Experimental transmission spectra show a mode cut-off around 1562.5 nm for the fundamental photonic bandgap mode. In order to measure and model the group index of modes in the PCW, a time-of-flight (ToF) method is applied....

  15. Measuring daily Value-at-Risk of SSEC index: A new approach based on multifractal analysis and extreme value theory

    Science.gov (United States)

    Wei, Yu; Chen, Wang; Lin, Yu

    2013-05-01

    Recent studies in the econophysics literature reveal that price variability has fractal and multifractal characteristics not only in developed financial markets, but also in emerging markets. Taking high-frequency intraday quotes of the Shanghai Stock Exchange Component (SSEC) Index as example, this paper proposes a new method to measure daily Value-at-Risk (VaR) by combining the newly introduced multifractal volatility (MFV) model and the extreme value theory (EVT) method. Two VaR backtesting techniques are then employed to compare the performance of the model with that of a group of linear and nonlinear generalized autoregressive conditional heteroskedasticity (GARCH) models. The empirical results show the multifractal nature of price volatility in Chinese stock market. VaR measures based on the multifractal volatility model and EVT method outperform many GARCH-type models at high-risk levels.

  16. Extended-range grazing-incidence spectrometer for high-resolution extreme ultraviolet measurements on an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.; Magee, E. W.; Brown, G. V.; Träbert, E.; Widmann, K. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2014-11-15

    A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 μm wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

  17. Measurement and Analysis of Extreme Wave and Ice Actions in the Great Lakes for Offshore Wind Platform Design

    Energy Technology Data Exchange (ETDEWEB)

    England, Tony [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering; van Nieuwstadt, Lin [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering; De Roo, Roger [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering; Karr, Dale [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering; Lozenge, David [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering; Meadows, Guy [Univ. of Michigan, Ann Arbor, MI (United States). College of Engineering

    2016-05-30

    This project, funded by the Department of Energy as DE-EE0005376, successfully measured wind-driven lake ice forces on an offshore structure in Lake Superior through one of the coldest winters in recent history. While offshore regions of the Great Lakes offer promising opportunities for harvesting wind energy, these massive bodies of freshwater also offer extreme and unique challenges. Among these challenges is the need to anticipate forces exerted on offshore structures by lake ice. The parameters of interest include the frequency, extent, and movement of lake ice, parameters that are routinely monitored via satellite, and ice thickness, a parameter that has been monitored at discrete locations over many years and is routinely modeled. Essential relationships for these data to be of use in the design of offshore structures and the primary objective of this project are measurements of maximum forces that lake ice of known thicknesses might exert on an offshore structure.

  18. Pulse wave transit time measured by imaging photoplethysmography in upper extremities

    Science.gov (United States)

    Volynsky, M. A.; Mamontov, O. V.; Sidorov, I. S.; Kamshilin, A. A.

    2016-08-01

    We describe highly reliable measurement method of the pulse wave transit time (PWTT) to human limbs by using simultaneous recordings of imaging photoplethysmography and electrocardiography. High accuracy of measurements was achieved by access to a larger number of statistically independent data obtained simultaneously in different points. The method is characterized by higher diagnostic reliability because of automatic selection of the regions less affected by environmental noise. The technique was tested in the group of 12 young healthy subjects aged from 21 to 33 years. Even though PWTT in right and left hands was comparable after averaging over the whole group of subjects, significant difference in the time delay of pulse wave between the hands was found in several individuals. The technique can be used for early-stage diagnostics of various vascular diseases.

  19. Operational Risk Measurement of Chinese Commercial Banks Based on Extreme Value Theory

    Science.gov (United States)

    Song, Jiashan; Li, Yong; Ji, Feng; Peng, Cheng

    The financial institutions and supervision institutions have all agreed on strengthening the measurement and management of operational risks. This paper attempts to build a model on the loss of operational risks basing on Peak Over Threshold model, emphasizing on weighted least square, which improved Hill’s estimation method, while discussing the situation of small sample, and fix the sample threshold more objectively basing on the media-published data of primary banks loss on operational risk from 1994 to 2007.

  20. Radio emission of air showers with extremely high energy measured by the Yakutsk Radio Array

    Science.gov (United States)

    Knurenko, S. P.; Petrov, Z. E.; Petrov, I. S.

    2017-09-01

    The Yakutsk Array is designed to study cosmic rays at energy 1015 -1020 eV . It consists several independent arrays that register charged particles, muons with energy E ≥ 1 GeV , Cherenkov light and radio emission. The paper presents a technical description of the Yakutsk Radio Array and some preliminary results obtained from measurements of radio emission at 30-35 MHz frequency induced by air shower particles with energy ε ≥ 1 ·1017 eV . The data obtained at the Yakutsk array in 1986-1989 (first set of measurements) and 2009-2014 (new set of measurements). Based on the obtained results we determined: Lateral distribution function (LDF) of air showers radio emission with energy ≥1017 eV . Radio emission amplitude empirical connection with air shower energy. Determination of depth of maximum by ratio of amplitude at different distances from the shower axis. For the first time, at the Yakutsk array radio emission from the air shower with energy >1019 eV was registered including the shower with the highest energy ever registered at the Yakutsk array with energy ∼ 2 ·1020 eV .

  1. Measurements of extreme orientation-dependent temperature increase around an irradiated gold nanorod

    DEFF Research Database (Denmark)

    Ma, Haiyan; Bendix, Pól Martin; Oddershede, Lene Broeng

    2012-01-01

    ] We developed a novel assay based on molecular partitioning between two coexisting phases, the gel and fluid phase, within the bilayer. [2, 3] This assay allows for a direct measurement of local temperature gradients, an assay which does not necessitate any pre-assumptions about...... this system and is generally applicable to any irradiated nanoparticle system. The nanorods are irradiated with a tightly focused laser beam at a wavelength of 1064 nm where biological matter exhibits a minimum in absorption. By controlling the polarization of the laser light we show that the absorption...

  2. Pressure-stability of phospholipid bicelles: Measurement of residual dipolar couplings under extreme conditions

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, E.; Arnold, M.R.; Kremer, W.; Kalbitzer, H.R. [University of Regensburg, Institute of Biophysics and Physical Biochemistry (Germany)

    2001-10-15

    High-pressure NMR of proteins in solutions currently gains increasing interest. 3D structure determination of proteins under high pressure is, however, so far impossible due to the lack of NOE information. Residual dipolar couplings induced by the addition of magnetically orienting media are known to be capable of replacing NOE information to a very high extent. In the present contribution we study the pressure-wstability of dimyristoylphosphatidylcholine (DMPC)/ dihexanoylphosphatidylcholine (DHPC) bicelles and demonstrate the feasibility of measuring residual dipolar couplings in proteins under high pressure.

  3. Measuring Occupational Exposure to Extremely Low-Frequency Electric Fields at 220 kV Substations.

    Science.gov (United States)

    Pirkkalainen, Herkko; Heiskanen, Timo; Tonteri, Juhani; Elovaara, Jarmo; Mika, Penttilä; Korpinen, Leena

    2017-03-03

    Earlier studies conducted at 400 and 110 kV substations in Finland have shown that the occupational exposure to electric fields can exceed the action levels (ALs) set by Directive 2013/35/EU. This is a case study investigating the level of occupational exposure experienced by workers at 220 kV substations in order to determine if the actions levels are being exceeded. The measurements were conducted at two old 220 kV substations in Finland. The higher AL of 20 kV m-1 was exceeded at both substations.

  4. Associations between Distal Upper Extremity Job Physical Factors and Psychosocial Measures in a Pooled Study

    Directory of Open Access Journals (Sweden)

    Matthew S. Thiese

    2015-01-01

    Full Text Available Introduction. There is an increasing body of literature relating musculoskeletal diseases to both job physical exposures and psychosocial outcomes. Relationships between job physical exposure measures and psychosocial factors have not been well examined or quantified. These exploratory analyses evaluate relationships between quantified exposures and psychosocial outcomes. Methods. Individualized quantification of duration, repetition, and force and composite scores of the Strain Index (SI and the Threshold Limit Value for Hand Activity Level (TLV for HAL were compared to 10 psychosocial measures. Relationships and predicted probabilities were assessed using ordered logistic regression. Analyses were adjusted for age, BMI, and gender. Results and Discussion. Among 1834 study participants there were multiple statistically significant relationships. In general, as duration, repetition, and force increased, psychosocial factors worsened. However, general health and mental exhaustion improved with increasing job exposures. Depression was most strongly associated with increased repetition, while physical exhaustion was most strongly associated with increased force. SI and TLV for HAL were significantly related to multiple psychosocial factors. These relationships persisted after adjustment for strong confounders. Conclusion. This study quantified multiple associations between job physical exposures and occupational and nonoccupational psychosocial factors. Further research is needed to quantify the impacts on occupational health outcomes.

  5. Attosecond streaking measurement of extreme ultraviolet pulses using a long-wavelength electric field

    Science.gov (United States)

    Saito, Nariyuki; Ishii, Nobuhisa; Kanai, Teruto; Watanabe, Shuntaro; Itatani, Jiro

    2016-01-01

    Long-wavelength lasers have great potential to become a new-generation drive laser for tabletop coherent light sources in the soft X-ray region. Because of the significantly low conversion efficiency from a long-wavelength light field to high-order harmonics, their pulse characterization has been carried out by measuring the carrier-envelope phase and/or spatial dependences of high harmonic spectra. However, these photon detection schemes, in general, have difficulty in obtaining information on the spectral phases, which is crucial to determine the temporal structures of high-order harmonics. Here, we report the first attosecond streaking measurement of high harmonics generated by few-cycle optical pulses at 1.7 μm from a BiB3O6–based optical parametric chirped-pulse amplifier. This is also the first demonstration of time-resolved photoelectron spectroscopy using high harmonics from a long-wavelength drive laser other than Ti:sapphire lasers, which paves the way towards ultrafast soft X-ray photoelectron spectroscopy. PMID:27752115

  6. Attosecond streaking measurement of extreme ultraviolet pulses using a long-wavelength electric field

    Science.gov (United States)

    Saito, Nariyuki; Ishii, Nobuhisa; Kanai, Teruto; Watanabe, Shuntaro; Itatani, Jiro

    2016-10-01

    Long-wavelength lasers have great potential to become a new-generation drive laser for tabletop coherent light sources in the soft X-ray region. Because of the significantly low conversion efficiency from a long-wavelength light field to high-order harmonics, their pulse characterization has been carried out by measuring the carrier-envelope phase and/or spatial dependences of high harmonic spectra. However, these photon detection schemes, in general, have difficulty in obtaining information on the spectral phases, which is crucial to determine the temporal structures of high-order harmonics. Here, we report the first attosecond streaking measurement of high harmonics generated by few-cycle optical pulses at 1.7 μm from a BiB3O6-based optical parametric chirped-pulse amplifier. This is also the first demonstration of time-resolved photoelectron spectroscopy using high harmonics from a long-wavelength drive laser other than Ti:sapphire lasers, which paves the way towards ultrafast soft X-ray photoelectron spectroscopy.

  7. Comprehensive quality control utilizing the prehybridization third-dye image leads to accurate gene expression measurements by cDNA microarrays

    Directory of Open Access Journals (Sweden)

    Jiang Nan

    2006-08-01

    Full Text Available Abstract Background Gene expression profiling using microarrays has become an important genetic tool. Spotted arrays prepared in academic labs have the advantage of low cost and high design and content flexibility, but are often limited by their susceptibility to quality control (QC issues. Previously, we have reported a novel 3-color microarray technology that enabled array fabrication QC. In this report we further investigated its advantage in spot-level data QC. Results We found that inadequate amount of bound probes available for hybridization led to significant, gene-specific compression in ratio measurements, increased data variability, and printing pin dependent heterogeneities. The impact of such problems can be captured through the definition of quality scores, and efficiently controlled through quality-dependent filtering and normalization. We compared gene expression measurements derived using our data processing pipeline with the known input ratios of spiked in control clones, and with the measurements by quantitative real time RT-PCR. In each case, highly linear relationships (R2>0.94 were observed, with modest compression in the microarray measurements (correction factor Conclusion Our microarray analytical and technical advancements enabled a better dissection of the sources of data variability and hence a more efficient QC. With that highly accurate gene expression measurements can be achieved using the cDNA microarray technology.

  8. Knowing what the brain is seeing in three dimensions: A novel, noninvasive, sensitive, accurate, and low-noise technique for measuring ocular torsion.

    Science.gov (United States)

    Otero-Millan, Jorge; Roberts, Dale C; Lasker, Adrian; Zee, David S; Kheradmand, Amir

    2015-01-01

    Torsional eye movements are rotations of the eye around the line of sight. Measuring torsion is essential to understanding how the brain controls eye position and how it creates a veridical perception of object orientation in three dimensions. Torsion is also important for diagnosis of many vestibular, neurological, and ophthalmological disorders. Currently, there are multiple devices and methods that produce reliable measurements of horizontal and vertical eye movements. Measuring torsion, however, noninvasively and reliably has been a longstanding challenge, with previous methods lacking real-time capabilities or suffering from intrusive artifacts. We propose a novel method for measuring eye movements in three dimensions using modern computer vision software (OpenCV) and concepts of iris recognition. To measure torsion, we use template matching of the entire iris and automatically account for occlusion of the iris and pupil by the eyelids. The current setup operates binocularly at 100 Hz with noise <0.1° and is accurate within 20° of gaze to the left, to the right, and up and 10° of gaze down. This new method can be widely applicable and fill a gap in many scientific and clinical disciplines.

  9. Total Cross Sections as a Surrogate for Neutron Capture: An Opportunity to Accurately Constrain (n,γ) Cross Sections for Nuclides Beyond the Reach of Direct Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Paul E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-03-05

    There are many (n,γ) cross sections of great interest to radiochemical diagnostics and to nuclear astrophysics which are beyond the reach of current measurement techniques, and likely to remain so for the foreseeable future. In contrast, total neutron cross sections currently are feasible for many of these nuclides and provide almost all the information needed to accurately calculate the (n,γ) cross sections via the nuclear statistical model (NSM). I demonstrate this for the case of 151Sm; NSM calculations constrained using average resonance parameters obtained from total cross section measurements made in 1975, are in excellent agreement with recent 151Sm (n,γ) measurements across a wide range of energy. Furthermore, I demonstrate through simulations that total cross section measurements can be made at the Manuel Lujan Jr. Neutron Scattering Center at the Los Alamos Neutron Science Center for samples as small as 10μg. Samples of this size should be attainable for many nuclides of interest. Finally, I estimate that over half of the radionuclides identified ~20 years ago as having (n,γ) cross sections of importance to s-process nucleosynthesis studies (24/43) and radiochemical diagnostics (11/19), almost none of which have been measured, can be constrained using this technique.

  10. Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies.

    Science.gov (United States)

    Noorkõiv, Marika; Rodgers, Helen; Price, Christopher I

    2014-10-09

    The aim of this review was to identify and summarise publications, which have reported clinical applications of upper limb accelerometry for stroke within free-living environments and make recommendations for future studies. Data was searched from MEDLINE, Scopus, IEEExplore and Compendex databases. The final search was 31st October 2013. Any study was included which reported clinical assessments in parallel with accelerometry in a free-living hospital or home setting. Study quality is reflected by participant numbers, methodological approach, technical details of the equipment used, blinding of clinical measures, whether safety and compliance data was collected. First author screened articles for inclusion and inclusion of full text articles and data extraction was confirmed by the third author. Out of 1375 initial abstracts, 8 articles were included. All participants were stroke patients. Accelerometers were worn for either 24 hours or 3 days. Data were collected as summed acceleration counts over a specified time or as the duration of active/inactive periods. Activity in both arms was reported by all studies and the ratio of impaired to unimpaired arm activity was calculated in six studies. The correlation between clinical assessments and accelerometry was tested in five studies and significant correlations were found. The efficacy of a rehabilitation intervention was assessed using accelerometry by three studies: in two studies both accelerometry and clinical test scores detected a post-treatment difference but in one study accelerometry data did not change despite clinical test scores showing motor and functional improvements. Further research is needed to understand the additional value of accelerometry as a measure of upper limb use and function in a clinical context. A simple and easily interpretable accelerometry approach is required.

  11. Analytical robustness of nine common assays: frequency of outliers and extreme differences identified by a large number of duplicate measurements.

    Science.gov (United States)

    Neubig, Stefanie; Grotevendt, Anne; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid

    2017-02-15

    Duplicate measurements can be used to describe the performance and analytical robustness of assays and to identify outliers. We performed about 235,000 duplicate measurements of nine routinely measured quantities and evaluated the observed differences between the replicates to develop new markers for analytical performance and robustness. Catalytic activity concentrations of aspartate aminotransferase (AST), alanine aminotransferase (ALT), and concentrations of calcium, cholesterol, creatinine, C-reactive protein (CRP), lactate, triglycerides and thyroid-stimulating hormone (TSH) in 237,261 patient plasma samples were measured in replicates using routine methods. The performance of duplicate measurements was evaluated in scatterplots with a variable and symmetrical zone of acceptance (A-zone) around the equal line. Two quality markers were established: 1) AZ95: the width of an A-zone at which 95% of all duplicate measurements were within this zone; and 2) OPM (outliers per mille): the relative number of outliers if an A-zone width of 5% was applied. The AZ95 ranges from 3.2% for calcium to 11.5% for CRP and the OPM from 5 (calcium) to 250 (creatinine). Calcium, TSH and cholesterol have an AZ95 of less than 5% and an OPM of less than 50. Duplicate measurements of a large number of patient samples identify even low frequencies of extreme differences and thereof defined outliers. We suggest two additional quality markers, AZ95 and OPM, to complement description of assay performance and robustness. This approach can aid the selection process of measurement procedures in view of clinical needs.

  12. Rapid, accurate, and non-invasive measurement of zebrafish axial length and other eye dimensions using SD-OCT allows longitudinal analysis of myopia and emmetropization.

    Directory of Open Access Journals (Sweden)

    Ross F Collery

    Full Text Available Refractive errors in vision can be caused by aberrant axial length of the eye, irregular corneal shape, or lens abnormalities. Causes of eye length overgrowth include multiple genetic loci, and visual parameters. We evaluate zebrafish as a potential animal model for studies of the genetic, cellular, and signaling basis of emmetropization and myopia. Axial length and other eye dimensions of zebrafish were measured using spectral domain-optical coherence tomography (SD-OCT. We used ocular lens and body metrics to normalize and compare eye size and relative refractive error (difference between observed retinal radial length and controls in wild-type and lrp2 zebrafish. Zebrafish were dark-reared to assess effects of visual deprivation on eye size. Two relative measurements, ocular axial length to body length and axial length to lens diameter, were found to accurately normalize comparisons of eye sizes between different sized fish (R2=0.9548, R2=0.9921. Ray-traced focal lengths of wild-type zebrafish lenses were equal to their retinal radii, while lrp2 eyes had longer retinal radii than focal lengths. Both genetic mutation (lrp2 and environmental manipulation (dark-rearing caused elongated eye axes. lrp2 mutants had relative refractive errors of -0.327 compared to wild-types, and dark-reared wild-type fish had relative refractive errors of -0.132 compared to light-reared siblings. Therefore, zebrafish eye anatomy (axial length, lens radius, retinal radius can be rapidly and accurately measured by SD-OCT, facilitating longitudinal studies of regulated eye growth and emmetropization. Specifically, genes homologous to human myopia candidates may be modified, inactivated or overexpressed in zebrafish, and myopia-sensitizing conditions used to probe gene-environment interactions. Our studies provide foundation for such investigations into genetic contributions that control eye size and impact refractive errors.

  13. Prospects for measuring supermassive black hole masses with future extremely large telescopes

    CERN Document Server

    Do, Tuan; Barth, Aaron J; Barton, Elizabeth J; Simard, Luc; Larkin, James E; Moore, Anna M; Wang, Lianqi; Ellerbroek, Brent

    2014-01-01

    The next generation of giant-segmented mirror telescopes ($>$ 20 m) will enable us to observe galactic nuclei at much higher angular resolution and sensitivity than ever before. These capabilities will introduce a revolutionary shift in our understanding of the origin and evolution of supermassive black holes by enabling more precise black hole mass measurements in a mass range that is unreachable today. We present simulations and predictions of the observations of nuclei that will be made with the Thirty Meter Telescope (TMT) and the adaptive optics assisted integral-field spectrograph IRIS, which is capable of diffraction-limited spectroscopy from $Z$ band (0.9 $\\mu$m) to $K$ band (2.2 $\\mu$m). These simulations, for the first time, use realistic values for the sky, telescope, adaptive optics system, and instrument, to determine the expected signal-to-noise ratio of a range of possible targets spanning intermediate mass black holes of $\\sim10^4$ \\msun to the most massive black holes known today of $>10^{10}...

  14. A portable analog lock-in amplifier for accurate phase measurement and application in high-precision optical oxygen concentration detection

    Science.gov (United States)

    Chen, Xi; Chang, Jun; Wang, Fupeng; Wang, Zongliang; Wei, Wei; Liu, Yuanyuan; Qin, Zengguang

    2016-10-01

    A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014 degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.

  15. A portable analog lock-in amplifier for accurate phase measurement and application in high-precision optical oxygen concentration detection

    Science.gov (United States)

    Chen, Xi; Chang, Jun; Wang, Fupeng; Wang, Zongliang; Wei, Wei; Liu, Yuanyuan; Qin, Zengguang

    2017-03-01

    A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014 degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.

  16. S3 HMBC: Spin-State-Selective HMBC for accurate measurement of homonuclear coupling constants. Application to strychnine yielding thirteen hitherto unreported JHH

    Science.gov (United States)

    Kjaerulff, Louise; Benie, Andrew J.; Hoeck, Casper; Gotfredsen, Charlotte H.; Sørensen, Ole W.

    2016-02-01

    A novel method, Spin-State-Selective (S3) HMBC, for accurate measurement of homonuclear coupling constants is introduced. As characteristic for S3 techniques, S3 HMBC yields independent subspectra corresponding to particular passive spin states and thus allows determination of coupling constants between detected spins and homonuclear coupling partners along with relative signs. In the presented S3 HMBC experiment, spin-state selection occurs via large one-bond coupling constants ensuring high editing accuracy and unequivocal sign determination of the homonuclear long-range relative to the associated one-bond coupling constant. The sensitivity of the new experiment is comparable to that of regular edited HMBC and the accuracy of the J/RDC measurement is as usual for E.COSY and S3-type experiments independent of the size of the homonuclear coupling constant of interest. The merits of the method are demonstrated by an application to strychnine where thirteen JHH coupling constants not previously reported could be measured.

  17. Novel echocardiographic approach to the accurate measurement of pulmonary vascular resistance based on a theoretical formula in patients with left heart failure -- pilot study.

    Science.gov (United States)

    Kanda, Takashi; Fujita, Masashi; Iida, Osamu; Masuda, Masaharu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Shiraki, Tatsuya; Takahara, Mitsuyoshi; Sakata, Yasushi; Uematsu, Masaaki

    2015-01-01

    Several non-invasive methods for measuring pulmonary vascular resistance (PVR) have been proposed to date, but they remain empirical, lacking sufficient accuracy to be used in clinical practice. The aims of this study were to propose a novel echocardiographic measurement of PVR based on a theoretical formula and investigate the feasibilty and accuracy of this method in patients with heart failure. Echocardiography was performed in 27 patients before right heart catheterization. Peak tricuspid regurgitation pressure gradient (TRPG), pulmonary regurgitation pressure gradient in end-diastole (PRPGed), and cardiac output derived from the time-velocity integral and the diameter in the left ventricular outflow tract (COLVOT) were measured. PVR based on a theoretical formula (PVRtheo) was calculated as (TRPG-PRPGed)/3COLVOTin Wood units (WU). The results were compared with PVR obtained by right heart catheterization (PVRcath) using linear regression and Bland-Altman analysis. Mean PVRcathwas 2.4±1.4 WU. PVRtheocorrelated well with PVRcath(r=0.83, P<0.001). On Bland-Altman analysis the mean difference was 0.1±0.7 WU. The limits of agreements were smaller than for other non-invasive estimations previously reported. The new echocardiographic approach based on a theoretical formula provides a non-invasive and accurate assessment of PVR in patients with heart failure.

  18. Measurements of HIFU-induced Lesions in BSA Gel Phantoms for HIFU Treatment of Varicose Veins of Lower Extremity

    Science.gov (United States)

    Ushijima, Hiroyuki; Senoo, Naohiko; Suzuki, Jun; Ichiyanagi, Mitsuhisa; Yoshinaka, Kiyoshi; Deguchi, Juno; Takagi, Shu; Miyata, Tetsuro; Matsumoto, Yoichiro

    2011-09-01

    HIFU treatment has been developed for various diseases because of its minimal invasiveness, and we are now developing a HIFU treatment for varicose veins of the lower extremity. Previous studies have succeeded in occluding rabbit's veins with HIFU, but the success rate was low (about 10%). Failures were mainly caused by skin burns. When the heating lesion comes close to skin, the absorbed ultrasound energy may cause skin burns. Therefore, it is necessary to study the relationships between HIFU lesions and skin burns to improve the success rate. To visualize heating lesions from HIFU, we used tissue-mimicking BSA gel phantoms. We tried various concentrations of BSA in gels, and determined 14% BSA as the most suitable for phantoms for experiments. The attenuation coefficient of the gel was 0.73 dB/cm, and the denaturation temperature was 70 °C. We put the BSA gel phantom in a water tank in which the temperature was kept at 39 °C, and used HIFU exposures at various intensities and irradiation times. After irradiation, we measured the sizes and positions of HIFU-induced lesions, and the results indicate that the sizes of lesion become larger when the intensitiy rises or irradiation time becomes longer. Furthermore, when the intensity rises and irradiation time becomes longer, the heating lesions move closer to upper surface of the gel, which means skin easily gets burned. Thus we have investigated relationships between HIFU parameters and heated lesions that can be used for further research into HIFU treatment of varicose veins of the lower extremity.

  19. Translating measurement findings into rehabilitation practice: An example using Fugl-Meyer Assessment-Upper Extremity with patients following stroke

    Directory of Open Access Journals (Sweden)

    Craig A. Velozo, PhD, OTR/L

    2011-12-01

    Full Text Available Standardized assessments are critical for advancing clinical rehabilitation, yet assessment scores often provide little information for rehabilitation treatment planning. A keyform recovery map is an innovative way for a therapist to record patient responses to standardized assessment items. The form enables a therapist to view the specific items that a patient can or cannot perform. This information can assist a therapist in tailoring treatments to a patient’s individual ability level. We demonstrate how a keyform recovery map can be used to inform clinical treatment planning for individuals with stroke-related upper-limb motor impairment. A keyform map of poststroke upper-limb recovery defined by items of the Fugl-Meyer Assessment-Upper Extremity (FMA-UE was generated by a previously published Rasch analysis. Three individuals with stroke enrolled in a separate research study were randomly selected from each of the three impairment strata of the FMA-UE. Their performance on each item was displayed on the FMA-UE keyform. The forms directly connected qualitative descriptions of patients’ motor ability to assessment measures, thereby suggesting appropriate shorter and longer term rehabilitation goals. This study demonstrates how measurement theory can be used to translate a standardized assessment into a useful, evidence-based tool for making clinical practice decisions.

  20. Validation of the Microsoft Kinect® camera system for measurement of lower extremity jump landing and squatting kinematics.

    Science.gov (United States)

    Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher

    2016-01-01

    Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.

  1. Accurate measurements and temperature dependence of the water vapor self-continuum absorption in the 2.1 μm atmospheric window

    Energy Technology Data Exchange (ETDEWEB)

    Ventrillard, I.; Romanini, D.; Mondelain, D.; Campargue, A., E-mail: Alain.Campargue@ujf-grenoble.fr [LIPhy, Université Grenoble Alpes, F-38000 Grenoble (France); LIPhy, CNRS, F-38000 Grenoble (France)

    2015-10-07

    In spite of its importance for the evaluation of the Earth radiative budget, thus for climate change, very few measurements of the water vapor continuum are available in the near infrared atmospheric windows especially at temperature conditions relevant for our atmosphere. In addition, as a result of the difficulty to measure weak broadband absorption signals, the few available measurements show large disagreements. We report here accurate measurements of the water vapor self-continuum absorption in the 2.1 μm window by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) for two spectral points located at the low energy edge and at the center of the 2.1 μm transparency window, at 4302 and 4723 cm{sup −1}, respectively. Self-continuum cross sections, C{sub S}, were retrieved with a few % relative uncertainty, from the quadratic dependence of the spectrum base line level measured as a function of water vapor pressure, between 0 and 16 Torr. At 296 K, the C{sub S} value at 4302 cm{sup −1} is found 40% higher than predicted by the MT-CKD V2.5 model, while at 4723 cm{sup −1}, our value is 5 times larger than the MT-CKD value. On the other hand, these OF-CEAS C{sub S} values are significantly smaller than recent measurements by Fourier transform spectroscopy at room temperature. The temperature dependence of the self-continuum cross sections was also investigated for temperatures between 296 K and 323 K (23-50 °C). The derived temperature variation is found to be similar to that derived from previous Fourier transform spectrometer (FTS) measurements performed at higher temperatures, between 350 K and 472 K. The whole set of measurements spanning the 296-472 K temperature range follows a simple exponential law in 1/T with a slope close to the dissociation energy of the water dimer, D{sub 0} ≈ 1100 cm{sup −1}.

  2. Simultaneous measurement in mass and mass/mass mode for accurate qualitative and quantitative screening analysis of pharmaceuticals in river water.

    Science.gov (United States)

    Martínez Bueno, M J; Ulaszewska, Maria M; Gomez, M J; Hernando, M D; Fernández-Alba, A R

    2012-09-21

    A new approach for the analysis of pharmaceuticals (target and non-target) in water by LC-QTOF-MS is described in this work. The study has been designed to assess the performance of the simultaneous quantitative screening of target compounds, and the qualitative analysis of non-target analytes, in just one run. The features of accurate mass full scan mass spectrometry together with high MS/MS spectral acquisition rates - by means of information dependent acquisition (IDA) - have demonstrated their potential application in this work. Applying this analytical strategy, an identification procedure is presented based on library searching for compounds which were not included a priori in the analytical method as target compounds, thus allowing their characterization by data processing of accurate mass measurements in MS and MS/MS mode. The non-target compounds identified in river water samples were ketorolac, trazodone, fluconazole, metformin and venlafaxine. Simultaneously, this strategy allowed for the identification of other compounds which were not included in the library by screening the highest intensity peaks detected in the samples and by analysis of the full scan TOF-MS, isotope pattern and MS/MS spectra - the example of loratadine (histaminergic) is described. The group of drugs of abuse selected as target compounds for evaluation included analgesics, opioids and psychostimulants. Satisfactory results regarding sensitivity and linearity of the developed method were obtained. Limits of detection for the selected target compounds were from 0.003 to 0.01 μg/L and 0.01 to 0.5 μg/L, in MS and MS/MS mode, respectively - by direct sample injection of 100 μL.

  3. CLARREO Cornerstone of the Earth Observing System: Measuring Decadal Change Through Accurate Emitted Infrared and Reflected Solar Spectra and Radio Occultation

    Science.gov (United States)

    Sandford, Stephen P.

    2010-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is one of four Tier 1 missions recommended by the recent NRC Decadal Survey report on Earth Science and Applications from Space (NRC, 2007). The CLARREO mission addresses the need to provide accurate, broadly acknowledged climate records that are used to enable validated long-term climate projections that become the foundation for informed decisions on mitigation and adaptation policies that address the effects of climate change on society. The CLARREO mission accomplishes this critical objective through rigorous SI traceable decadal change observations that are sensitive to many of the key uncertainties in climate radiative forcings, responses, and feedbacks that in turn drive uncertainty in current climate model projections. These same uncertainties also lead to uncertainty in attribution of climate change to anthropogenic forcing. For the first time CLARREO will make highly accurate, global, SI-traceable decadal change observations sensitive to the most critical, but least understood, climate forcings, responses, and feedbacks. The CLARREO breakthrough is to achieve the required levels of accuracy and traceability to SI standards for a set of observations sensitive to a wide range of key decadal change variables. The required accuracy levels are determined so that climate trend signals can be detected against a background of naturally occurring variability. Climate system natural variability therefore determines what level of accuracy is overkill, and what level is critical to obtain. In this sense, the CLARREO mission requirements are considered optimal from a science value perspective. The accuracy for decadal change traceability to SI standards includes uncertainties associated with instrument calibration, satellite orbit sampling, and analysis methods. Unlike most space missions, the CLARREO requirements are driven not by the instantaneous accuracy of the measurements, but by accuracy in

  4. The development and validation of a novel outcome measure to quantify mobility in the dysvascular lower extremity amputee: the amputee single item mobility measure

    Science.gov (United States)

    Norvell, Daniel C; Williams, Rhonda M; Turner, Aaron P; Czerniecki, Joseph M

    2016-01-01

    Objective: This study describes the development and psychometric evaluation of a novel patient-reported single-item mobility measure. Design: Prospective cohort study. Setting: Four Veteran’s Administration Medical Centers. Subjects: Individuals undergoing their first major unilateral lower extremity amputation; 198 met inclusion criteria; of these, 113 (57%) enrolled. Interventions: None. Main measures: The Amputee Single Item Mobility Measure, a single item measure with scores ranging from 0 to 6, was developed by an expert panel, and concurrently administered with the Locomotor Capabilities Index-5 (LCI-5) and other outcome measures at six weeks, four months, and 12 months post-amputation. Criterion and construct validity, responsiveness, and floor/ceiling effects were evaluated. Responsiveness was assessed using the standardized response mean. Results: The overall mean 12-month Amputee Single Item Mobility Measure score was 3.39 ±1.4. Scores for transmetatarsal, transtibial, and transfemoral amputees were 4.2 (±1.3), 3.2 (±1.5), and 2.9 (±1.1), respectively. Amputee Single Item Mobility Measure scores demonstrated “large” and statistically significant correlations with the LCI-5 scores at six weeks (r = 0.72), four months (r = 0.81), and 12 months (r = 0.86). At four months and 12 months, the correlation between Amputee Single Item Mobility Measure scores and hours of prosthetic use were r = 0.69 and r = 0.66, respectively, and between Amputee Single Item Mobility Measure scores and Trinity Amputation and Prosthesis Experience Scales functional restriction scores were r = 0.45 and r = 0.67, respectively. Amputee Single Item Mobility Measure scores increased significantly from six weeks to 12 months post-amputation. Minimal floor/ceiling effects were demonstrated. Conclusions: In the unilateral dysvascular amputee, the Amputee Single Item Mobility Measure has strong criterion and construct validity, excellent

  5. Soft X-ray irradiance measured by the Solar Aspect Monitor on the Solar Dynamic Observatory Extreme ultraviolet Variability Experiment

    CERN Document Server

    Lin, C Y; Jones, A; Woodraska, D; Caspi, A; Woods, T N; Eparvier, F G; Wieman, S R; Didkovsky, L V

    2016-01-01

    The Solar Aspect Monitor (SAM) is a pinhole camera on the Extreme-ultraviolet Variability Experiment (EVE) aboard the Solar Dynamics Observatory (SDO). SAM projects the solar disk onto the CCD through a metallic filter designed to allow only solar photons shortward of 7 nm to pass. Contamination from energetic particles and out-of-band irradiance is, however, significant in the SAM observations. We present a technique for isolating the 0.01--7 nm integrated irradiance from the SAM signal to produce the first results of broadband irradiance for the time period from May 2010 to May 2014. The results of this analysis agree with a similar data product from EVE's EUV SpectroPhotometer (ESP) to within 25%. We compare our results with measurements from the Student Nitric Oxide Explorer (SNOE) Solar X-ray Photometer (SXP) and the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) Solar EUV Experiment (SEE) at similar levels of solar activity. We show that the full-disk SAM broadband results compare we...

  6. Application of exercise transcutaneous oxygen pressure measurements for detection of proximal lower extremity arterial disease: a case report.

    Science.gov (United States)

    Mahe, Guillaume; Kalra, Manju; Abraham, Pierre; Liedl, David A; Wennberg, Paul W

    2015-06-01

    Proximal claudication is secondary to ischemia caused by peripheral artery disease (PAD), whereas proximal pseudo-claudication is secondary to other disease processes such as hip arthritis, spinal stenosis, neuropathy, and so forth. The differentiation between the two can be challenging. Exercise transcutaneous oxygen pressure measurement (exercise-TcPO2) allows noninvasive detection of flow-reducing lesions in the proximal arteries and tributaries of the lower extremity arterial tree. We present the first case report in the United States using an exercise-TcPO2 algorithm. A 71-year-old diabetic patient with proximal left-sided and right-calf claudication with indeterminate ankle-brachial indices underwent an exercise-TcPO2 study before and after endovascular intervention. Four TcPO2 probes were placed: one at chest level (reference probe), one on each buttock, and one on the symptomatic calf. The Delta from Resting Oxygen Pressure (DROP) index was calculated at each probe site using a previously validated protocol. Proximal left- and right-calf ischemia were confirmed by the initial exercise-TcPO2, and, after endovascular treatment of the left iliac artery lesion, improvements in proximal exercise-TcPO2 values were found. These data suggest that exercise-TcPO2 can be useful in PAD evaluation in patients with non-compressible arteries and/or proximal claudication.

  7. Climate Change: A New Metric to Measure Changes in the Frequency of Extreme Temperatures using Record Data

    Science.gov (United States)

    Munasinghe, L.; Jun, T.; Rind, D. H.

    2012-01-01

    Consensus on global warming is the result of multiple and varying lines of evidence, and one key ramification is the increase in frequency of extreme climate events including record high temperatures. Here we develop a metric- called "record equivalent draws" (RED)-based on record high (low) temperature observations, and show that changes in RED approximate changes in the likelihood of extreme high (low) temperatures. Since we also show that this metric is independent of the specifics of the underlying temperature distributions, RED estimates can be aggregated across different climates to provide a genuinely global assessment of climate change. Using data on monthly average temperatures across the global landmass we find that the frequency of extreme high temperatures increased 10-fold between the first three decades of the last century (1900-1929) and the most recent decade (1999-2008). A more disaggregated analysis shows that the increase in frequency of extreme high temperatures is greater in the tropics than in higher latitudes, a pattern that is not indicated by changes in mean temperature. Our RED estimates also suggest concurrent increases in the frequency of both extreme high and extreme low temperatures during 2002-2008, a period when we observe a plateauing of global mean temperature. Using daily extreme temperature observations, we find that the frequency of extreme high temperatures is greater in the daily minimum temperature time-series compared to the daily maximum temperature time-series. There is no such observable difference in the frequency of extreme low temperatures between the daily minimum and daily maximum.

  8. Any condomless anal intercourse is no longer an accurate measure of HIV sexual risk behaviour in gay and other men who have sex with men

    Directory of Open Access Journals (Sweden)

    Fengyi eJin

    2015-02-01

    Full Text Available Background: Condomless anal intercourse (CLAI has long been recognised as the primary mode of sexual transmission of HIV in gay and other men who have sex with men (MSM. A variety of measures of CLAI have been commonly used in behavioural surveillance for HIV risk and to forecast trends in HIV infection. However, gay and other MSM’s sexual practices changed as the understanding of disease and treatment options advance. In the present paper, we argue that summary measures such as any CLAI do not accurately measure HIV sexual risk behaviour. Methods: Participants were 1,427 HIV-negative men from the Health in Men cohort study run from 2001 to 2007 in Sydney, Australia, with six-monthly interviews. At each interview, detailed quantitative data on the number of episodes of insertive and receptive CLAI in the last six months were collected, separated by partner type (regular vs. casual and partners’ HIV status (negative, positive, and HIV status unknown.Results: A total of 228,064 episodes of CLAI were reported during the study period with a mean of 44 episodes per year per participant (median: 14. The great majority of CLAI episodes were with a regular partner (92.6%, most of them with HIV-negative regular partners (84.8%. Participants were more likely to engage in insertive CLAI with casual than with regular partners (66.7% vs. 55.3% of all acts of CLAI with each partner type, p<0.001. Men were more likely to report CLAI in the receptive position with HIV-negative and HIV status unknown partners than with HIV-positive partners (p<0.001 for both regular and casual partners. Conclusion: Gay and other MSM engaging in CLAI demonstrate clear patterns of HIV risk reduction behaviour. As HIV prevention enters the era of antiretroviral-based biomedical approach, using all forms of CLAI indiscriminately as a measure of HIV behavioural risk is not helpful in understanding the current drivers of HIV transmission in the community.

  9. Extreme Heat

    Science.gov (United States)

    ... Landslides & Debris Flow Nuclear Blast Nuclear Power Plants Power Outages Pandemic Radiological Dispersion Device Severe Weather Snowstorms & Extreme ... Landslides & Debris Flow Nuclear Blast Nuclear Power Plants Power Outages Pandemic Radiological Dispersion Device Severe Weather Snowstorms & Extreme ...

  10. Mandelbrot's Extremism

    NARCIS (Netherlands)

    Beirlant, J.; Schoutens, W.; Segers, J.J.J.

    2004-01-01

    In the sixties Mandelbrot already showed that extreme price swings are more likely than some of us think or incorporate in our models.A modern toolbox for analyzing such rare events can be found in the field of extreme value theory.At the core of extreme value theory lies the modelling of maxima

  11. NEW ACCURATE MEASUREMENT OF {sup 36}ArH{sup +} AND {sup 38}ArH{sup +} RO-VIBRATIONAL TRANSITIONS BY HIGH RESOLUTION IR ABSORPTION SPECTROSCOPY

    Energy Technology Data Exchange (ETDEWEB)

    Cueto, M.; Herrero, V. J.; Tanarro, I.; Doménech, J. L. [Molecular Physics Department, Instituto de Estructura de la Materia (IEM-CSIC), Serrano 123, E-28006 Madrid (Spain); Cernicharo, J. [Department of Astrophysics, CAB. INTA-CSIC. Crta Torrejón-Ajalvir Km 4, E-28850 Torrejón de Ardoz, Madrid (Spain); Barlow, M. J.; Swinyard, B. M., E-mail: jl.domenech@csic.es [Department of Physics and Astronomy, University College London. Gower Street, London WC1E 6BT (United Kingdom)

    2014-03-01

    The protonated argon ion, {sup 36}ArH{sup +}, was recently identified in the Crab Nebula from Herschel spectra. Given the atmospheric opacity at the frequency of its J = 1-0 and J = 2-1 rotational transitions (617.5 and 1234.6 GHz, respectively), and the current lack of appropriate space observatories after the recent end of the Herschel mission, future studies on this molecule will rely on mid-infrared observations. We report on accurate wavenumber measurements of {sup 36}ArH{sup +} and {sup 38}ArH{sup +} rotation-vibration transitions in the v = 1-0 band in the range 4.1-3.7 μm (2450-2715 cm{sup –1}). The wavenumbers of the R(0) transitions of the v = 1-0 band are 2612.50135 ± 0.00033 and 2610.70177 ± 0.00042 cm{sup –1} (±3σ) for {sup 36}ArH{sup +} and {sup 38}ArH{sup +}, respectively. The calculated opacity for a gas thermalized at a temperature of 100 K and with a linewidth of 1 km s{sup –1} of the R(0) line is 1.6 × 10{sup –15} × N({sup 36}ArH{sup +}). For column densities of {sup 36}ArH{sup +} larger than 1 × 10{sup 13} cm{sup –2}, significant absorption by the R(0) line can be expected against bright mid-IR sources.

  12. Improvement of a questionnaire measuring activity limitations in rising and sitting down in patients with lower-extremity disorders living at home

    NARCIS (Netherlands)

    Roorda, LD; Molenaar, IW; Lankhorst, GJ; Bouter, LM

    2005-01-01

    Objective: To improve a self-administered questionnaire that includes 42 dichotomous items and measures activity limitations in rising and sitting down (R&S) in patients with lower-extremity disorders who live at home. Design: Cross-sectional study. Setting: Outpatient clinics of secondary and

  13. Measuring activity limitations in walking : Development of a hierarchical scale for patients with lower-extremity disorders who live at home

    NARCIS (Netherlands)

    Roorda, LD; Roebroeck, ME; van Tilburg, T; Molenaar, IW; Lankhorst, GJ; Bouter, LM

    2005-01-01

    Objective: To develop a hierarchical scale that measures activity limitations in walking in patients with lower-extremity disorders who live at home. Design: Cross-sectional study. Setting: Orthopedic workshops and outpatient clinics of secondary and tertiary care centers. Participants: Patients (N=

  14. A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ling; Xu, Zong; Wu, Zhenwei; Zhang, Pengfei; Wu, Chengrui; Gao, Wei; Shen, Junsong; Chen, Yingjie; Liu, Xiang; Wang, Yumin; Gong, Xianzu; Hu, Liqun; Chen, Junlin; Zhang, Xiaodong; Wan, Baonian; Li, Jiangang [Institute of Plasma Physics Chinese Academy of Sciences, Hefei 230026, Anhui (China); Morita, Shigeru; Ohishi, Tetsutarou; Goto, Motoshi [National Institute for Fusion Science, Toki 509-5292, Gifu (Japan); Department of Fusion Science, Graduate University for Advanced Studies, Toki 509-5292, Gifu (Japan); Dong, Chunfeng [Southwestern Institute of Physics, Chengdu 610041, Sichuan (China); and others

    2015-12-15

    A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

  15. Accurate measurements of vadose zone fluxes using automated equilibrium tension plate lysimeters: A synopsis of results from the Spydia research facility, New Zealand.

    Science.gov (United States)

    Wöhling, Thomas; Barkle, Greg; Stenger, Roland; Moorhead, Brian; Wall, Aaron; Clague, Juliet

    2014-05-01

    Automated equilibrium tension plate lysimeters (AETLs) are arguably the most accurate method to measure unsaturated water and contaminant fluxes below the root zone at the scale of up to 1 m². The AETL technique utilizes a porous sintered stainless-steel plate to provide a comparatively large sampling area with a continuously controlled vacuum that is in "equilibrium" with the surrounding vadose zone matric pressure to ensure measured fluxes represent those under undisturbed conditions. This novel lysimeter technique was used at an intensive research site for investigations of contaminant pathways from the land surface to the groundwater on a sheep and beef farm under pastoral land use in the Tutaeuaua subcatchment, New Zealand. The Spydia research facility was constructed in 2005 and was fully operational between 2006 and 2011. Extending from a central access caisson, 15 separately controlled AETLs with 0.2 m² surface area were installed at five depths between 0.4 m and 5.1 m into the undisturbed volcanic vadose zone materials. The unique setup of the facility ensured minimum interference of the experimental equipment and external factors with the measurements. Over the period of more than five years, a comprehensive data set was collected at each of the 15 AETL locations which comprises of time series of soil water flux, pressure head, volumetric water contents, and soil temperature. The soil water was regularly analysed for EC, pH, dissolved carbon, various nitrogen compounds (including nitrate, ammonia, and organic N), phosphorus, bromide, chloride, sulphate, silica, and a range of other major ions, as well as for various metals. Climate data was measured directly at the site (rainfall) and a climate station at 500m distance. The shallow groundwater was sampled at three different depths directly from the Spydia caisson and at various observation wells surrounding the facility. Two tracer experiments were conducted at the site in 2009 and 2010. In the 2009

  16. Study of radon measurement instrumentation in extreme environmental conditions; Estudio de la instrumentacion de medida de radon en condiciones ambientales extremas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, V.; Baixeras, C.; Amgarou, K.; Font, L.; Vargas, A.; Grossi, C.

    2011-07-01

    Within the framework of the scientific project of the Nuclear Safety Council ''Study of environmental monitoring instrumentation and measurement of radon in extreme environmental conditions' at the Universitat Autonoma de Barcelona has established a partnership with the Universitat Politecnica de Catalunya (UPC) to conduct a study to identify the most appropriate filters to minimize the influence of measurement conditions, particularly with respect to moisture on the response of continuous radon detectors and integrators. (Author)

  17. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE ...

    Science.gov (United States)

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with P significantly reduced the bioavailability of Pb. The bioaccessibility of the Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter 24%, or present as Pb sulfate 18%. Ad

  18. Measuring the Extreme Risks in SME Stock Market Based on the Exponential Regression Model%基于指数回归模型的中小企业板极端风险度量

    Institute of Scientific and Technical Information of China (English)

    刘琼芳; 张宗益; 吴俊

    2011-01-01

    not reflect pinnacles and fat-tails in the distribution of asset returns.In summary, our POT model with exponential regression method can effectively measure the extreme risk in SME Board. The SME stock market is a key for constructing the multilayer capital market system. Therefore, accurate depiction of SME stock market risks has significant reference values.%中小企业板有着区别于沪深主板市场的风险特征.本文针对传统基于正态分布假设的VaR模型低估风险问题,运用极值POT模型研究中小企业板的极端风险,利用指数回归模型实现了POT模型中阈值的定量选取,避免了样本Hill图在选取阈值时存在的局限性.实证结果表明,POT模型对中小企业板极端风险的估计比正态分布更有效.研究还发现,传统基于正态分布的风险度量没有体现金融资产收益率的尖峰厚尾特征,同时存在低估风险和高估风险,但都很难通过LR统计量检验.因此,基于指数回归法的POT模型更能有效刻画中小企业板的极端风险.

  19. Measuring activity limitations in climbing stairs: development of a hierarchical scale for patients with lower-extremity disorders living at home.

    Science.gov (United States)

    Roorda, Leo D; Roebroeck, Marij E; van Tilburg, Theo; Lankhorst, Gustaaf J; Bouter, Lex M

    2004-06-01

    To develop a hierarchical scale that measures activity limitations in climbing stairs in patients with lower-extremity disorders living at home. Cross-sectional study with Mokken scale analysis of 15 dichotomous items. Outpatient clinics of secondary and tertiary care centers. Patients (N=759; mean age +/- standard deviation, 59.8+/-15.0y; 48% men) living at home, with different lower-extremity disorders: stroke, poliomyelitis, osteoarthritis, amputation, complex regional pain syndrome type I, and diabetic foot problems. Not applicable. (1) Fit of the monotone homogeneity model, indicating whether items can be used for measuring patients; (2) fit of the double monotonicity model, indicating invariant (hierarchical) item ordering; (3) intratest reliability, indicating repeatability of the sum score; and (4) differential item functioning, addressing the validity of comparisons between subgroups of patients. There was (1) good fit of the monotone homogeneity model (coefficient H=.50) for all items for all patients, and for subgroups defined by age, gender, and diagnosis; (2) good fit of the double monotonicity model (coefficient H(T)=.58); (3) good intratest reliability (coefficient rho=.90); and (4) no differential item functioning with respect to age and gender, but differential item functioning for 4 items in amputees compared with nonamputees. A hierarchical scale, with excellent scaling characteristics, has been developed for measuring activity limitations in climbing stairs in patients with lower-extremity disorders who live at home. However, measurements should be interpreted with caution when comparisons are made between patients with and without amputation.

  20. In situ rheological measurements at extreme pressure and temperature using synchrotron X-ray diffraction and radiography.

    Science.gov (United States)

    Raterron, Paul; Merkel, Sébastien

    2009-11-01

    Dramatic technical progress seen over the past decade now allows the plastic properties of materials to be investigated under extreme pressure and temperature conditions. Coupling of high-pressure apparatuses with synchrotron radiation significantly improves the quantification of differential stress and specimen textures from X-ray diffraction data, as well as specimen strains and strain rates by radiography. This contribution briefly reviews the recent developments in the field and describes state-of-the-art extreme-pressure deformation devices and analytical techniques available today. The focus here is on apparatuses promoting deformation at pressures largely in excess of 3 GPa, namely the diamond anvil cell, the deformation-DIA apparatus and the rotational Drickamer apparatus, as well as on the methods used to carry out controlled deformation experiments while quantifying X-ray data in terms of materials rheological parameters. It is shown that these new techniques open the new field of in situ investigation of materials rheology at extreme conditions, which already finds multiple fundamental applications in the understanding of the dynamics of Earth-like planet interior.