WorldWideScience

Sample records for extraction radiotracer technique

  1. Hydrophilic actinide complexation studied by solvent extraction radiotracer technique

    International Nuclear Information System (INIS)

    Rydberg, J.

    1996-10-01

    Actinide migration in the ground water is enhanced by the formation of water soluble complexes. It is essential to the risk analysis of a wet repository to know the concentration of central atoms and the ligands in the ground water, and the stability of complexes formed between them. Because the chemical behavior at trace concentrations often differ from that at macro concentrations, it is important to know the chemical behavior of actinides at trace concentrations in ground water. One method used for such investigations is the solvent extraction radiotracer (SXRT) technique. This report describes the SXRT technique in some detail. A particular reason for this analysis is the claim that complex formation constants obtained by SXRT are less reliable than results obtained by other techniques. It is true that several difficulties are encountered in the application of SXRT technique to actinide solution, such as redox instability, hydrophilic complexation by side reactions and sorption, but it is also shown that a careful application of the SXRT technique yields results as reliable as by any other technique. The report contains a literature survey on solvent extraction studies of actinide complexes formed in aqueous solutions, particularly by using the organic reagent thenoyltrifluoroacetone (TTA) dissolved in benzene or chloroform. Hydrolysis constants obtained by solvent extraction are listed as well as all actinide complexes studied by SX with inorganic and organic ligands. 116 refs, 11 tabs

  2. Hydrophilic actinide complexation studied by solvent extraction radiotracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Rydberg, J [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Nuclear Chemistry and Radiochemistry Consultant Group, Vaestra Froelunda (Sweden)

    1996-10-01

    Actinide migration in the ground water is enhanced by the formation of water soluble complexes. It is essential to the risk analysis of a wet repository to know the concentration of central atoms and the ligands in the ground water, and the stability of complexes formed between them. Because the chemical behavior at trace concentrations often differ from that at macro concentrations, it is important to know the chemical behavior of actinides at trace concentrations in ground water. One method used for such investigations is the solvent extraction radiotracer (SXRT) technique. This report describes the SXRT technique in some detail. A particular reason for this analysis is the claim that complex formation constants obtained by SXRT are less reliable than results obtained by other techniques. It is true that several difficulties are encountered in the application of SXRT technique to actinide solution, such as redox instability, hydrophilic complexation by side reactions and sorption, but it is also shown that a careful application of the SXRT technique yields results as reliable as by any other technique. The report contains a literature survey on solvent extraction studies of actinide complexes formed in aqueous solutions, particularly by using the organic reagent thenoyltrifluoroacetone (TTA) dissolved in benzene or chloroform. Hydrolysis constants obtained by solvent extraction are listed as well as all actinide complexes studied by SX with inorganic and organic ligands. 116 refs, 11 tabs.

  3. Development of Radiotracer Techniques in Industry

    International Nuclear Information System (INIS)

    Wardono

    2000-01-01

    Contribution of radiotracer techniques to solve problems in industrial process plants have been recognized since a long time. Radiotracer application was governed by three main components, namely radioisotopes, radiation detection and data interpretation of an experiment. The three main components mentioned above have been continually developed to overcome problems relating to the operation of industrial process plants. The availability of isotope generator is one of the development aspect in radiotracer technique. Radiation hazard in radiotracer experiment may be reduced by applying isotope generator and on the other hand the delivery of radiotracer to the plant site from the radioisotopes producer was made easier. The development of microprocessor in computer system has facilitated data recording, storing and retrieving. Development in mathematical model supported by radiotracer experiment enhance data interpretation and shed light on various phenomena of flow process. Generally a flow dynamic in a process plant in all kind of industries can be studied using radiotracer technique. However the main challenge coming from petroleum, petrochemical and mineral processing industries

  4. Radiotracer techniques in hydrological studies

    International Nuclear Information System (INIS)

    Oladipo, M.O.A.; Funtua, I.I.

    2000-07-01

    The use of radioactive tracers particularly short-lived radioisotopes frequently offers advantages over conventional methods of analyses. Applications of nuclear techniques in the field of hydrology constitute important and sometimes unique tools for obtaining critical information needed for water resources management. Essentially, radiotracer techniques offer a safe, cost effective and powerful tool in the assessment, management and protection of water resources. The Centre for Energy Research and Training, Ahmadu Bello University, Zaria of late has been offering consultancy services to some industries in the area of radiotracer technique. The first nuclear reactor in Nigeria, the MNSR, is expected to be commissioned in the Centre very soon. Many short-lived radioisotopes such as Cu-64, Ga-72, Br-82, Hg-197 etc which are very important in hydrological studies can be produced by the MNSR facility. This article reports on the basic principles of the technique and its roles in hydrology

  5. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique.

    Science.gov (United States)

    Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  6. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique

    International Nuclear Information System (INIS)

    Ghiyas Ud Din; Imran Rafiq Chughtai; Mansoor Hameed Inayat; Iqbal Hussain Khan

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and 99m Tc in the form of sodium pertechnetate eluted from a 99 Mo/ 99m Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer 99m Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  7. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  8. The extraction of low-concentrations of gold(I) with 198Au as a radiotracer

    International Nuclear Information System (INIS)

    Jianzhun Jiang; Chunli Liu; Weijin Zhou; Hongcheng Gao

    2002-01-01

    The solvent extraction of gold from alkaline cyanide solution was studied by using 198 Au as a radiotracer. The influence of several variables on the gold extraction, including the concentration of gold, the molar ratio of extractants to gold(I), the volume percentage of cosolvent and the pH value of the aqueous phase, was investigated. The results indicated that the radioactive tracer technique is a quick, accurate, and convenient tool to investigate the extraction behavior of an element existing in low concentrations. The experimental results indicated that the studied amines, tetradecyldimethylbenzylammonium chloride, N1923 and tri-n-octylamine, could be used as extractants for the recovery of gold from aqueous alkaline cyanide solutions. (author)

  9. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  10. Research reactors serving the radiotracer technique: An overlooked opportunity?

    International Nuclear Information System (INIS)

    Bode, P.

    2010-01-01

    gaseous form,e.g.using 41 Ar or 81m Kr. Ga seous radionuclide open the door for interesting applications in technology processes to study gas-liquid contacts and/or gas-flow kinetics in which hardly any other technique can compete. Various examples will be given of research programs in Delft in which radiotracers were made using the nuclear research reactor.

  11. Radiotracer methodology

    International Nuclear Information System (INIS)

    Eng, R.R.

    1988-01-01

    In 1923, George Hevesy demonstrated the distribution of radioactive lead in the horsebean plant. This early demonstration of the potential use of radiotracers in biology was reinforced when J.G. Hamilton and colleagues used iodine-131 for diagnostic purposes in patients. Then in 1950 Cassen et al. designed the first scintillation counter for measuring radioiodine in the body, using calcium tungstate crystals coupled to a photomultiplier tube. This was followed by the development of the Anger camera, which permitted visualization of radiotracer distribution in biological systems. From these significant early discoveries to the present, many advances have been made. They include the discovery and production of many useful radioisotopes; the formulation of these radioisotopes into useful radiotracers; the advent of first- , and second-, and third-generation instrumentation for monitoring in vitro and in vivo distributions of new radiotracers; and the application of this knowledge to allow us to better understand physiological processes and treat disease states. Radiotracer techniques are integral to numerous techniques described in this volume. Autoradiography, nuclear scintigraphy, positron emission tomography, and single-photon emission computed tomography (SPECT) are all dependent on an understanding of radiotracer techniques to properly utilize these probe devices

  12. Investigation of flow behaviour of coal particles in a pilot-scale fluidized bed gasifier (FBG) using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Kamudu, M Vidya; Prakash, S G; Krishanamoorthy, S; Anandam, G; Rao, P Seshubabu; Ramani, N V S; Singh, Gursharan; Sonde, R R

    2009-09-01

    Knowledge of residence time distribution (RTD), mean residence time (MRT) and degree of axial mixing of solid phase is required for efficient operation of coal gasification process. Radiotracer technique was used to measure the RTD of coal particles in a pilot-scale fluidized bed gasifier (FBG). Two different radiotracers i.e. lanthanum-140 and gold-198 labeled coal particles (100 gm) were independently used as radiotracers. The radiotracer was instantaneously injected into the coal feed line and monitored at the ash extraction line at the bottom and gas outlet at the top of the gasifier using collimated scintillation detectors. The measured RTD data were treated and MRTs of coal/ash particles were determined. The treated data were simulated using tanks-in-series model. The simulation of RTD data indicated good degree of mixing with small fraction of the feed material bypassing/short-circuiting from the bottom of the gasifier. The results of the investigation were found useful for optimizing the design and operation of the FBG, and scale-up of the gasification process.

  13. Studies on the electrochemical behaviour of iron by the use of radio-tracer technique, 1. Studies on the electrodeposition and dissolution of iron by the use of radio-tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Moritani, Kimikazu; Ito, Yasuhiko; Kamata, Masahiro; Oishi, Jun

    1984-12-01

    To investigate whether radio-tracer techniques can augment conventional electrochemical techniques, offering useful information about the electrochemical behaviour of iron, the current efficiency of the electrodeposition of iron and the corrosion rate of metallic iron were measured by the radio-tracer method and the results were compared with the results measured by gravimetry and absorption photometry. Major conclusions obtained by the experiments are summarized as: 1) Between ordinary Fe and /sup 59/Fe, no isotope effect was observed. 2) Radiation from /sup 59/Fe had no effect on the electrode reaction. 3) While the use of a Ge semiconductor detector is undoubtedly preferable, Geiger-Mueller counter or NaI(Tl) scintillation counter gave fully satisfactory results. 4) Electrodeposited iron corrodes several times more rapidly than the iron base metal. These results suggests many other interesting applications of the radio-tracer technique when it is desired to obtain more detailed information on the electrochemical behaviour of iron. (author).

  14. A study of residence time distribution using radiotracer technique in the large scale plant facility

    Science.gov (United States)

    Wetchagarun, S.; Tippayakul, C.; Petchrak, A.; Sukrod, K.; Khoonkamjorn, P.

    2017-06-01

    As the demand for troubleshooting of large industrial plants increases, radiotracer techniques, which have capability to provide fast, online and effective detections to plant problems, have been continually developed. One of the good potential applications of the radiotracer for troubleshooting in a process plant is the analysis of Residence Time Distribution (RTD). In this paper, the study of RTD in a large scale plant facility using radiotracer technique was presented. The objective of this work is to gain experience on the RTD analysis using radiotracer technique in a “larger than laboratory” scale plant setup which can be comparable to the real industrial application. The experiment was carried out at the sedimentation tank in the water treatment facility of Thailand Institute of Nuclear Technology (Public Organization). Br-82 was selected to use in this work due to its chemical property, its suitable half-life and its on-site availability. NH4Br in the form of aqueous solution was injected into the system as the radiotracer. Six NaI detectors were placed along the pipelines and at the tank in order to determine the RTD of the system. The RTD and the Mean Residence Time (MRT) of the tank was analysed and calculated from the measured data. The experience and knowledge attained from this study is important for extending this technique to be applied to industrial facilities in the future.

  15. Applications of radiotracer techniques for the toxicology studies of nanomaterials

    International Nuclear Information System (INIS)

    Ma Yuhui; Zhang Zhiyong; Zhang Yuan; He Xiao; Zhang Haifeng; Chai Zhifang

    2008-01-01

    With the rapid development of nanosciences and nanotechnology, a wide variety of manufactured nanomaterials are now used in commodities, pharmaceutics, cosmetics, biomedical products, and industries. While nanomaterials possess more novel and unique physicochemical properties than bulk materials, they also have an unpredictable impact on human health. In the toxicology studies of nanomaterials, it is essential to know the basic behaviors in vivo, that is absorption, distribution, metabolism, and excretion (ADME) of these newly designed materials. Radiotracer techniques are especially well suited to such studies and has got the chance to demonstrate its enchantment. In this presentation, studies on radiotracer techniques used in nanotoxicology will be reviewed and new progresses at Institute of High Energy Physics, including the label methods and behaviors of labeled nanomaterials, such as fullerene, carbon nanotubes, and nanometer metal oxide in animals and in aquatic environments will be reported. (authors)

  16. Radiotracer technique to predict irritation potential of soap

    International Nuclear Information System (INIS)

    Castaneda, S.S.; Garcia, T.Y.; Santos, F.L.

    1990-01-01

    The application of a radiotracer technique using tritiated water to predict the irritation potentials of some soap products is demonstrated. Collagen films are treated with 0.5% and 1.0% soap solutions and tritiated water then incubated at 50 degrees centigrade for 24 hours. After incubation, the uptake of tritiated water by the collagen films was measured by liquid scintillation counting. (Auth.). 6 refs., 2 tabs

  17. Determination of oil reservoir radiotracer (S14CN−) in a single step using a plastic scintillator extractive resin

    International Nuclear Information System (INIS)

    Bagán, H.; Tarancón, A.; Stavsetra, L.; Rauret, G.; García, J.F.

    2012-01-01

    Highlights: ► A new procedure for S 14 CN − radiotracer determination using PS resin was established. ► The minimum detectable activity for a 100 mL sample is 0.08 Bq L −1 . ► The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L −1 . ► PS resin is capable to quantify S 14 CN − radiotracer samples with errors lower than 5%. ► PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S 14 CN − . Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of 14 C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L −1 and 0.31 Bq L −1 , respectively. The established procedure was applied to active samples from oil reservoirs and errors lower than 5% in the sample

  18. Role of radiotracer in animal science

    International Nuclear Information System (INIS)

    Sivaprasad, N.

    2015-01-01

    Radiotracers have been used as radiopharmaceuticals for diagnosis and treatment of animal diseases in cattle and pet animals. In fact the veterinary nuclear medicine based on radiotracer as radiopharmaceuticals is established medical technique for functional studies and imaging of vital organs such as heart, lung, brain, spleen, liver, kidney etc for diagnosis as well as treatment of diseases such as cancers in animal. Besides, radiation from radioisotopes has been in use for radiation therapy of cancers in animals. The nuclear imaging using positron emitting radiotracer is gaining importance in the evolution of drug in small animals. In this respect, small animals have also contributed significantly in the development of radiopharmaceuticals particularly for biodistribution and bioscan studies. In fact, the quality control of radiopharmaceuticals in animals to test the safety is a mandatory requirement in the production of radiopharmaceuticals. In brief the animal science has contributed in various areas and facets of radiotracer techniques and its application vice versa the radiotracer techniques have contributed towards the progress of animal science. The animal science in combination with radiotracer has also contributed to the progress of other basic and applied sciences. Thus there exists a bond between radiotracer techniques and animal science. Some aspects of mutual dependence of animal science and radiotracer are elaborated

  19. The use of rare earth radiotracers in the study of solvent extraction kinetics

    International Nuclear Information System (INIS)

    Lim, T.M.; Tran, T.

    1993-01-01

    The suitability of rare earth radionuclides as tracers in research and industry are assessed. In general, the most desirable characteristics of radiotracers for process studies are a half-life in the range 5-200 days, a high yield, high energy γ-emission and low cost of production. The majority of rare earths have at least one radionuclide with acceptable characteristics. The application of radiotracers to the study of kinetics of rare earth solvent extraction have been studied using a modified Lewis cell. Terbium-160 was selected as the most suitable rare earth radionuclide for our experiments. Samples of both aqueous and organic phases were continuous withdrawn, monitored using an automated γ-counting system based on two sodium iodide detectors and then pumped back to the Lewis cell. Excellent results were obtained and the rate of extraction was shown to be first order with respect to the terbium concentration. 6 refs., 1 tab., 7 figs

  20. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    International Nuclear Information System (INIS)

    2008-01-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  1. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  2. Leak Detection in Heat Exchangers and Underground Pipelines Using Radiotracers. Material for Education and On-The-Job Training for Practitioners of Radiotracer Technology

    International Nuclear Information System (INIS)

    2009-01-01

    The International Atomic Energy Agency plays a major role in facilitating the transfer of radiotracer technology to developing Member States. The use of radiotracer techniques is well established in many Member States; some hundred radiotracer and end user specialists have been trained in radiotracer techniques and their applications; nearly 50 radiotracer laboratories have been working in this field. The training of radiotracer practitioners is vital for the provision of quality services to industry. Leak detection using radiotracer techniques is probably one of the most widespread applications of radiotracers in industrial troubleshooting. Radiotracer techniques are the most competitive for online leak inspection of heat exchangers and buried pipelines. Radiotracers help in early detection of leaks in heat exchangers and underground transporting pipelines, thus saving money, reducing shutdown time, ensuring safe operation and protecting the environment from pollution. The training course series on leak detection in heat exchangers and underground pipelines using radiotracers addresses the needs of the radiotracer groups and their end users. Besides training purposes, this material will assist radiotracer groups in establishing their quality control and accreditation systems. This training course material is based on lecture notes and practical work delivered by many experts in IAEA-supported activities. In particular, the Technical Cooperation Projects implemented under the Regional Cooperative Agreement (RCA) of the IAEA Member States in the Asia and the Pacific Region have been successful in transferring and implementing radiotracer techniques for leak detection to many end users from oil and gas production, oil refineries and the petrochemical industry. The experience obtained in the RCA Region is presented in the training material illustrated with many case studies carried out in several RCA Member States. Lectures and case studies were reviewed by a number

  3. Determination of oil reservoir radiotracer (S{sup 14}CN{sup -}) in a single step using a plastic scintillator extractive resin

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Stavsetra, L. [Department for Reservoir and Exploration Technology, Institute for Energy Technology (IFE), Instituttveien 18, N-2027 Kjeller (Norway); Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain)

    2012-07-29

    Highlights: Black-Right-Pointing-Pointer A new procedure for S{sup 14}CN{sup -} radiotracer determination using PS resin was established. Black-Right-Pointing-Pointer The minimum detectable activity for a 100 mL sample is 0.08 Bq L{sup -1}. Black-Right-Pointing-Pointer The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L{sup -1}. Black-Right-Pointing-Pointer PS resin is capable to quantify S{sup 14}CN{sup -} radiotracer samples with errors lower than 5%. Black-Right-Pointing-Pointer PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S{sup 14}CN{sup -}. Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of {sup 14}C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L{sup -1

  4. Radiotracer Generators for Industrial Applications

    International Nuclear Information System (INIS)

    2013-01-01

    Radiotracers have been widely used throughout industry to optimize processes, solve problems, improve product quality, save energy and reduce pollution. Their technical, economic and environmental benefits have been recognized by both the industrial and the environmental sectors. The most important radiotracer techniques have been transferred to many developing Member States through IAEA Technical Cooperation projects. However, in spite of their manifest benefits, radiotracer techniques continue to be underutilized, not only by developing countries but also by more industrialized nations. There are a number of factors that restrict the usage of the radioisotope techniques, but chief among them is the timely availability of suitable radiotracers. Ensuring timely availability of suitable radionuclides is a main hurdle to the use of radiotracer techniques in industry. For developing countries that do not possess radioisotope production facilities, the long time required for import of radionuclides not only completely rules out the use of short half-life nuclides, but also makes it impossible for the radioisotope applications teams to respond to problems of an urgent nature. Many possible radiotracer investigations are not being carried out in developing countries because of this problem. Even in industrialized countries, radionuclide supply is often a problem, as many of the former suppliers of industrial radionuclides have switched their production facilities to serve the more lucrative radiopharmaceuticals market. Obtaining continuity of supply of radionuclides with which to carry out extended studies in difficult-to-access locations, such as offshore oil platforms, is also a significant challenge. Making use of tracers from radionuclide generators can alleviate the difficulties associated with radioisotope supply. Two commercially available medical radionuclide generators, 99 Mo/ 99 mTc and 113 Sn/ 113 mIn, have been used for this purpose, but their use has been

  5. Extraction of the mixture 99mTcO4- tributilfosfato- 30% 16% trioctylamine in cyclohexane evaluation of radiotracer obtained

    International Nuclear Information System (INIS)

    Ortega Pijeira, Martha Sahyli; Dominguez Catasus, Judith; Martinez Baez, Ernesto; Borroto Portela, Jorge

    2014-01-01

    Tracer technology plays an important role in industry development and has been widely used to optimize process, solve problems and improve product quality. In the last years Cuban scientific have studied the 99m TcO 4 - , eluted from 99 Mo/ 99m Tc generator, extraction with the mixture 30 % tributylphosphate -16 % trioctylamine in cyclohexane, in order to get an organic radiotracer. In this paper, the influence on 99m TcO 4 - extraction of stirring speed, contact time and NaCl concentration were studied. The extractant's role was also studied and, the tracer's homogeneity in diesel, special gasoline and Venezuelan oils was evaluated to normal pressure and temperature. The obtained outcomes showed that the NaCl concentration only influences on the extraction process when it is less than 0.17 %. Furthermore, the employed mixture's synergism was noticed and, could be conclude that, the obtained tracer is a physical radiotracer for the used industrial supports to 95 % trustworthy

  6. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  7. The application of radiotracer technique for preconcentration neutron activation analysis

    International Nuclear Information System (INIS)

    Wang Xiaolin; Chen Yinliang; Sun Ying; Fu Yibei

    1995-01-01

    The application of radiotracer technique for preconcentration neutron activation analysis (Pre-NAA) are studied and the method for determination of chemical yield of Pre-NAA is developed. This method has been applied to determination of gold, iridium and rhenium in steel and rock samples and the contents of noble metal are in the range of 1-20 ng·g -1 (sample). In addition, the accuracy difference caused by determination of chemical yield between RNAA and Pre-NAA are also discussed

  8. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Shenoy, K.T.; Sreenivas, T.

    2015-01-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40–60 MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. - Highlights: • Radiotracer technique was applied for evaluation of design of a pilot-scale continuous leaching reactor. • Mean residence time and dead volume were estimated. Dead volume was found to be ranging from 4% to 15% at different operating conditions. • Tank-in-series model was used to simulate the measured RTD data and was found suitable to describe the flow in the reactor. • No flow abnormality was found and the reactor behaved as a well-mixed system. The design of the reactor was validated

  9. Residence time distribution measurements in a pilot-scale poison tank using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Goswami, Sunil; Samantray, J S; Sharma, V K; Maheshwari, N K

    2015-09-01

    Various types of systems are used to control the reactivity and shutting down of a nuclear reactor during emergency and routine shutdown operations. Injection of boron solution (borated water) into the core of a reactor is one of the commonly used methods during emergency operation. A pilot-scale poison tank was designed and fabricated to simulate injection of boron poison into the core of a reactor along with coolant water. In order to design a full-scale poison tank, it was desired to characterize flow of liquid from the tank. Residence time distribution (RTD) measurement and analysis was adopted to characterize the flow dynamics. Radiotracer technique was applied to measure RTD of aqueous phase in the tank using Bromine-82 as a radiotracer. RTD measurements were carried out with two different modes of operation of the tank and at different flow rates. In Mode-1, the radiotracer was instantaneously injected at the inlet and monitored at the outlet, whereas in Mode-2, the tank was filled with radiotracer and its concentration was measured at the outlet. From the measured RTD curves, mean residence times (MRTs), dead volume and fraction of liquid pumped in with time were determined. The treated RTD curves were modeled using suitable mathematical models. An axial dispersion model with high degree of backmixing was found suitable to describe flow when operated in Mode-1, whereas a tanks-in-series model with backmixing was found suitable to describe flow of the poison in the tank when operated in Mode-2. The results were utilized to scale-up and design a full-scale poison tank for a nuclear reactor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M., E-mail: anacamiqui@gmail.com, E-mail: egoncalves@con.ufrj.br, E-mail: brandao@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  11. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    International Nuclear Information System (INIS)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M.

    2017-01-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  12. Employment of the technique of radiotracers for analysis of industrial filters

    International Nuclear Information System (INIS)

    Ramos, Vitor Santos; Crispim, Verginia Reis

    2007-01-01

    The main aim of this work is to develop a methodology to evaluate the characteristics of porous media in filter using the radio-tracing technique. To do this, an experimental prototype filter made up of an acrylic cylinder, vertically mounted and supported on the lower side by a controlled leaking valve was developed. Two filters (spheres of acrylic and silica crystals) were used to check the movement of the water through the porous media using 123 I in its MIBG (iodine-123-meta-iodo benzyl-guanidine) form. Further up the filter an instantaneous injection of the substance makes it possible to see the passage of radioactive clouds through the two scintillatory detectors NaI (2x2) ' ' positioned before and immediately after the cylinder with the filtering element (porous media). The are caused by the detectors on the passage of the radioactive cloud are analyzed through statistical functions using the weighted moment method which makes it possible to calculate the Residence-Time (the amount of time the tracer takes to thoroughly pass through the filter) per the equation of dispersion in tubular flow and the one-directional flow of the radiotracer in the porous media. (author)

  13. 3. Radiotracers

    International Nuclear Information System (INIS)

    Musilek, L.

    1992-01-01

    The chapter deals with basic characteristics of radiotracer methods, with demands placed on radiotracers, their assets and drawbacks, the applicability of the method to the study of laminar flows, and examples of radiotracer applications in biochemistry, metallurgy, in the investigation of the permeation and passage of gases and liquids, in the examination of wear of machine components, and in criminological practice. An overview of the major radionuclides and of radiotracer applications is given. (Z.S.). 3 tabs., 5 figs., 25 refs

  14. Diagnosing plant pipeline system performance using radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kasban, H.; Ali, Elsayed H.; Arafa, H. [Engineering Department, Nuclear Research Center, Atomic Energy Authority, Inshas (Egypt)

    2017-02-15

    This study presents an experimental work in a petrochemical company for scanning a buried pipeline using Tc{sup 99m} radiotracer based on the measured velocity changes, in order to determine the flow reduction along a pipeline. In this work, Tc{sup 99m} radiotracer was injected into the pipeline and monitored by sodium iodide scintillation detectors located at several positions along the pipeline. The flow velocity has been calculated between every two consecutive detectors along the pipeline. Practically, six experiments have been carried out using two different data acquisition systems, each of them being connected to four detectors. During the fifth experiment, a bypass was discovered between the scanned pipeline and another buried parallel pipeline connected after the injection point. The results indicate that the bypass had a bad effect on the volumetric flow rate in the scanned pipeline.

  15. Radiotracer Applications in Wastewater Treatment Plants

    International Nuclear Information System (INIS)

    2011-01-01

    Wastewater containing pollutants resulting from municipal and industrial activities are normally collected in wastewater treatment plants (WWTPs) for processing before discharge to the environment. The WWTPs are the last barrier against contamination of downstream surface waters such as rivers, lakes and sea. Treated wastewater is reused for irrigation, particularly in arid and semi-arid countries. Therefore, it is very important to maintain optimal operating conditions of WWTPs to eliminate or reduce environmental pollution. Wastewater treatment plants are complicated systems, where the processes of mixing, separation, aeration, biological and chemical reactions occur. A WWTP is basically a multiphase system, and the efficiency of an installation strongly depends on liquid, solid and gas phase flow structures and their residence time distributions (RTDs). However, the fluid dynamic properties of such systems are not yet completely understood, rendering difficult the theoretical prediction of important process parameters such as flow rates, phase distributions, mixing and sediment characteristics. Tracer techniques are very useful tools to investigate the efficiency of purification in WWTPs, aiding both their design and performance optimization. There are many kinds of tracers. Radioactive tracers are the most sensitive and are largely used for on-line diagnosis of various operations in WWTPs. The success of radiotracer applications rests upon their extremely high detection sensitivity, and the strong resistance against severe process conditions. During the last few decades, many radiotracer studies have been conducted worldwide for investigation of various installations for wastewater treatment, such as mixer, aeration tank, clarifiers, digester, filter, wetland and oxidation units. Various radiotracer methods and techniques have been developed by individual tracer groups. However, the information necessary for the preservation of knowledge and transfer of

  16. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  17. Studies on In-situ Chelation/Supercritical Fluid Extraction of Lanthanides and Actinides Using a Radiotracer Technique

    International Nuclear Information System (INIS)

    Lin, Yuehe; Wu, Hong; Smart, Neil G.; Wai, Chien M.

    2001-01-01

    Radioisotope tracer techniques were used to study the process of in-situ chelation/supercritical fluid extraction(SFE) of La3+ and Lu3+ from solid matrix using mixed ligand hexafluoroacetylacetone (HFA) and tributylphosphate (TBP) as chelating agents. A lab-built SFE extactor was used in this study and the extractor design was optimized based on the experimental results. Quantitative recovery of La and Lu was achieved when the extrator design was optimized. Extraction of uranium from real world samples was also investigated to demonstrate the capability of this chelation/SFE technology for environmental remediation applications. A novel on-line back extraction technique for the recovery of metal ions and regeneration of ligands is also reported.

  18. Fostering the local production and application of industrial radiotracers in developing countries - IAEA's role

    International Nuclear Information System (INIS)

    Mohammad Haji-Saeid, S.; Jin, Joon-Ha; Ramamoorthy, Natesan; )

    2006-01-01

    Radiotracer techniques provide fast and accurate information for solving various process problems in industrial plants. The IAEA is playing an important role in supporting the development and transfer of radiotracer techniques to developing countries. The IAEA has implemented 5 coordinated research projects (CRP), including two on-going projects, in the field of radiotracer and sealed source applications in industry. The CRPs facilitated the acquisition and dissemination of know-how and technology for wear/corrosion measurement, residence time: distribution (RTD) study, validation of computed fluid dynamics data, industrial process tomography and inter-well connectivity study. A number of technical cooperation projects have been executed to strengthen the capability of radiotracer groups in developing Member States and to create awareness in the industries about the technical and economical benefits of radiotracer technology. The IAEA's regional projects have strongly impacted the transfer and adoption of the techniques. The status of radiotracer use in developing countries reveals that the lack of timely availability of radiotracers as one of the major problems. Development of some radionuclide generators is a possible solution. Cooperation among the international radiotracer communities is necessary to enhance the availability and use of radiotracers in developing countries. (author)

  19. Study of water flowrate using time transient and cross-correlation techniques with 82Br radiotracer

    International Nuclear Information System (INIS)

    Salgado, William L.; Brandao, Luiz E.B.

    2013-01-01

    This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI (T1) detectors adequately positioned on the outside of pipe and a gamma-ray source ( 82 Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowrate previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones. (author)

  20. Special aspects of the indirect radiotracer technique when used to study the adsorption and electrochemical reactions of organic substances at solid electrodes

    International Nuclear Information System (INIS)

    Andreev, V.N.; Horanyi, G.; Kazarinov, V.E.

    1986-01-01

    This paper analyzes the possibilities and special aspects of the indirect radiotracer technique with a number of examples. Data are presented concerning the effects of acetic and oxalic acid on chloride ion adsorption on platinized platinum electrodes at a potential E = 0.2 V. The effect on chloride ion adsorption is much larger in the case of oxalic acid, which is evidence for its higher adsorbability on platinum at E = 0.2 V. It is shown that the indirect radiotracer technique offers significant possibilities for studying the electrochemical properties of adsorption products of organic substances

  1. History and present status of field application of radiotracers, (2)

    International Nuclear Information System (INIS)

    Koyama, Takeo; Shimizu, Makoto.

    1988-01-01

    In the field of agriculture, radiotracers were first used in 1957 in studies for improvement in fertilizing techniques. Techniques were established for accurate measurement of extremely low radioactivity in crops and for the separate determination of the phosphorus in crops of the fertilizer origin and soil origin. Then, RI or stable isotope tracing test methods were developed using 32 P or 15 N to determine the flow and absorption of fertilizers. Other techniques using radiotracers developed in this period served for the construction of maps of the root activity of crops, investigation of the effects of different fertilizers in farms where double-cropping was practised, identification of suitable fertilizers for orange cultivation, development of new fertilizing techniques for Japanese persimmon cultivation, etc. Practically, no field use of radiotracers has been found since 1970. At present, it is prohibited and replaced by other techniques using stable isotopes, etc. In the field fishery, radiotracers have been used for studies of various dynamic phenomena including the flow of water and deposits in the sea, behaviors of fish, food, chain, circulation of chemical substances in the ecological system, etc. (Nogami, K.)

  2. Preliminary study of the use of radiotracers for leak detection in industrial applications

    International Nuclear Information System (INIS)

    Wetchagarun, S; Petchrak, A; Tippayakul, C

    2015-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH 4 Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system. (paper)

  3. Preliminary study of the use of radiotracers for leak detection in industrial applications

    Science.gov (United States)

    Wetchagarun, S.; Petchrak, A.; Tippayakul, C.

    2015-05-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.

  4. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  5. Radiotracer in industry

    International Nuclear Information System (INIS)

    Jaafar Abdullah

    2005-01-01

    The use of radiotracers for troubleshooting and to investigate process phenomena in industrial plant equipment has specific advantages over conventional tracers. The main advantages of radiotracers owes to its physico-chemical compatibility, high detection sensitivity, ability of number of radiotracers for different phases, stability in harsh industrial environment and limited memory effects. This chapter covers the methodology which includes the selection of radiotracer, radioisotope generators, estimation of amount of radiotracer, injection systems, detection system and safety procedure. Leak detection, this topic discussed the detection by flowrate measurement, detection of RTD measurement, detection by direct tracer, detection in underground pipes using the static method and dynamic method. The topic namely Radiotracers for flowrate measurement discussed the following subjects: flowrate measurement, transit time methods, dilution methods, standards for flow measurement, multi-phase flow measurement. RTD measurement, this topic covers the basic flow concepts, the mathematical modelling, RTD software, bypassing or channelling, recirculation, trickle bed reactors studies, process diagnosis and analysis. Lastly, the topic cover other application of radiotracers in industry discussed the following subtopics: mixing and blending studies, measurement of volume, ventilation studies, oil field investigation, corrosion and wear studies, validation of CFD models

  6. Radiotracer technique to study movement of pollutants in an alluvial aquifer

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2001-01-01

    Radioisotopes are being used as tracers in many research areas. Their use in determination of groundwater flow velocity is well known. They also provide insight into the understanding the hydrological systems. In this paper, pollutant movement in an alluvial aquifer in the Ganga basin near Kanpur is evaluated using radiotracer method. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater in the vicinity of an effluent storage lagoon of a fertilizer plant at Kanpur, U.P. Point dilution technique in a single well was applied. Filtration velocity so obtained provided relevant information about the pollutant movement in the groundwater. (author)

  7. Characterizing root activity of guava trees by radiotracer technique

    International Nuclear Information System (INIS)

    Purohit, A.G.; Mukherjee, S.K.

    1974-01-01

    The distribution pattern of root activity of 12-year-old trees of guava (Psidium guajava L.) was determined by radiotracer technique. 32 P soloution was injected into the soil at lateral distances of 120, 240 and 360 cm from the tree trunk at depths of 15,30,60 and 90 cm. The 32 P uptake by the tree was determined by leaf analysis. In the rainy season the root activity or 32 P uptake was greater near the soil surface and midway between the trunk and the drip-line. The root activity decreased with an increase in the depth and distance from trunk. These results compared well with the actual distribution of feeder roots as determined by the soil-auger method. In summer the roots near the surface become less active in 32 P absorption with a drcrease in surface soil moisture. A decrease in the root activity in the surface soil was accompanied by an increase in 32 P uptake from lower depths. (author)

  8. Leak detection in a high-pressure heat exchanger system in a refinery using radiotracer technique

    International Nuclear Information System (INIS)

    Samantray, J.S.; Sunil Goswami; Sharma, V.K.; Jayashree Biswal; Pant, H.J.

    2014-01-01

    A radiotracer investigation was carried out in a diesel hydrotreater (DHDT) unit in a refinery for leak detection in a breech-lock heat exchanger system. The main objectives of the study were to identify the leaking heat exchanger in a system with six heat exchangers and estimate the leak rate. Bromine-82 as dibromobiphenyl was selected and used as radiotracer for the investigation. The radiotracer was instantaneously injected into the suction end of the feed pump line to the heat exchanger of the DHDT unit. The movement of the tracer was measured at strategically selected locations using NaI(Tl) scintillation detectors. Based upon the results of the radiotracer investigation, it was found that out of six heat exchangers, exchanger E-1F was leaking. (author)

  9. Industrial applications of radiotracers in Indonesia

    International Nuclear Information System (INIS)

    Wandowo

    1994-01-01

    Applications of isotopes and radiation have been developed since 1970 at the Centre for Application of Isotopes and Radiation, National Atomic Energy Agency or BATAN. The scope of applications cover various fields, namely, agriculture, medicine, hydrology, sedimentology and industry. The use of radiotracers prove to be very beneficial for problem solving in industrial process plants and this technique will continuously be promoted by BATAN to industries in Indonesia. Several examples of radiotracer applications in industries which have been carried out by the Group of Industry of the Centre for Application of Isotopes and Radiation are presented. (author). 7 refs., 4 figs., 1 tab

  10. Application of Radiotracer Technology on Solving the Unsolved Leak in Lift Pit

    International Nuclear Information System (INIS)

    Mohd Fitri Abdul Rahman; Jaafar Abdullah; Hearie Hassan

    2016-01-01

    Radiotracers have been used in many fields to optimize processes, solve problems, improve product quality, save energy and reduce pollution. The radiotracer technology is a proven reliable technique and recognized by many sectors such as medical, industrial and environmental. In this work, an unsolved leak problem was present in lift pit within a building in Malaysia. Many techniques have applied such as dye techniques, chemical analyses and engineering plaster to overcome the problem. Unfortunately, none of the techniques solve the problem. Radiotracer was used to find the unidentified source of leak. Basically, Technetium (Tc-99m) has been injected to the several injection points and flow of the tracer was monitored with radiation detectors that have been placed at various locations. The results were successful and pinpoint the problems. (author)

  11. Spectrum analysis of radiotracer residence time distribution for industrial and environmental applications

    International Nuclear Information System (INIS)

    Kasban, H.; Ashraf Hamid

    2014-01-01

    Radiotracer signal analysis and recognition still represents challenges in industrial and environmental applications specially in residence time distribution (RTD) measurement. This paper presents a development for the RTD signal recognition method that is based on power density spectrum (PDS). In this development, the features are extracted from the signals and/or from their higher-orders statistics (HOS) (Bispectrum and Trispectrum) instead of PDS. The HOS are estimated using direct, indirect and parametric estimations. The recognition results are analyzed and compared for different HOS estimation in order to select the best HOS estimation method for the purpose of RTD signal recognition. The artificial neural networks are used for training and testing of the proposed method. The proposed method is tested using RTD signals obtained from the measurements carried out using radiotracer technique. The simulation results show that the parametric estimation of the Trispectrum gives the higher recognition rate and is the most reliable for the RTD signal recognition. (author)

  12. Investigation of leaching of an antifouling agent from marine paint formulations using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Kalgutkar, D.B.; Patil, S.P.; Jayachandran, N.; Unni, V.K.P.

    2012-01-01

    A radiotracer technique was used to investigate the leaching of an antifouling agent from different marine paint formulations with an objective to select the best paint formulation for bulk production. The antifouling agent (Diuron) itself was labeled with carbon-14 (half-life: 5,730 years, β-energy: 156 keV) and used as a radiotracer. The different paint formulations added with radiolabeled Diuron were applied onto suitably selected substrates and measured for initial intensity of β-radiation using a Geiger-Muller detector connected to a ratemeter. The painted substrates were subjected to shower tests for a pre-decided time and subsequently measured for β-radiations. The comparison of intensity of β-radiations in substrates prior and post shower tests provides information about leaching of antifouling agent Diuron from the paint formulation. The high leaching percentage of antifouling agent Diuron post shower tests indicates non-suitability of paint formulation for marine and civil structures. However, low leaching rate of Diuron will make a paint formulation more efficient and suitable. Based on the results of investigation, a paint formulation with minimum leaching rate was identified and selected for bulk production by a paint company. (author)

  13. Synthesis of new radiotracers

    International Nuclear Information System (INIS)

    Chahed, Ahlem

    2008-01-01

    The brain's sensibility besides to the rigorous selectivity of changes taking place on brain's barriers leads us to synthesis specifics radiotracers based on diamine ethylene and marked with technetium radioisotope to form a radiotracer able to pass these barriers and diagnose illnesses in an early stage. These radiotracers are tested by a biodistribution on a small animal to be ratified. (Author)

  14. Investigation of sediment transport and optimization of dredging operations in Indian ports using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.

    2012-01-01

    India has a long coastline of about 7,515 km and there are twelve major ports situated on the coastline. Out of them, six are situated on the West Coast whereas other six are situated on the East Coast. In addition to this, there are more than 140 minor ports and other marine establishments situated along the coastline. Each port and marine project has a navigation channel and depth of this navigation channel needs to be maintained to a level of at least 12-15 meters for smooth sailing of ships. Sediments continuously move along the coast due to alongshore currents generated by the waves and tides; and get deposited in navigation channels. For maintaining the required depth of the channels, the dredging operation is carried out. throughout the year or as and when required. Development of a new port or harbour also involves huge capital dredging. The dredged sediments generated during maintenance or capital dredging needs to be dumped at a suitable location, so that it does not find its way back to the channel and obstruct sailing of ships. Moreover the selected site should be such that the turn around time of the dredger is kept minimum to economize the dredging operation. In order to meet the above requirements, the knowledge of transport parameters such as the general direction of movement, extent of lateral and longitudinal movement, transport velocity, transport thickness and bed load movement rate is required. Radiotracer techniques are commonly used to investigate sediment transport on seabed and evaluate the suitability of the proposed dumping sites. Scandium-46 (half-life: 84 days, Gamma energies: 0.89 MeV (100%), 1.12 MeV (100%)) in the form of scandium glass powder is the most suitable radiotracer for tracing sediments on seabed. The activity used in an investigation ranges from 75-300 GBq (2-8 Ci). The suitably prepared particulate radiotracer is injected on seabed at the proposed site using a specially designed injection system and its movement is

  15. Radiotracer investigations for sediment transport in ports of India

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Goswami, Sunil; Singh, Gursharan

    2013-01-01

    The knowledge of mixing and transport of sediments in coastal region is of vital importance for evaluating suitability of dumping site for dredged sediments produced during maintenance of shipping channels, expansion of existing projects and construction of new projects. Gamma-emitting radiotracers are commonly used for investigation of movement of sediments on seabed using Scandium-46 (scandium glass powder) as radiotracer. The radiotracer is injected on seabed at a desired location and its movement followed over a period of time using waterproof NaI(Tl) scintillation detectors. The recorded data is analyzed to obtain transport parameters and utilized for assessing the suitability of the dumping sites and optimization of the dredging operations. About 70 large-scale investigations have been carried out in different ports in India leading to significant economical benefits to the Ports. Present paper discusses various aspects of the radiotracer technique for sediment transport, methodology of data analysis and a specific case study. (author)

  16. Determination of the hydrodynamic and morphological parameters of the Luyano River using radiotracer techniques

    International Nuclear Information System (INIS)

    Valcarcel, Lino; Alberro, Nancy; Rodriguez, Maydel; Herrero, Zahily; Borroto, Jorge; Hernandez, Anel; Dominguez, Judith; Derivet, Milagros; Flores, Pedro; Cuesta, Jaime; Griffith, Jose

    2011-01-01

    The hydrodynamic and morphological parameters (the times of travel, velocities and flowrates of the waters, and the average widths, cross sections and depths) in the middle segment of the river Luyano were determined combining the employment of sodium pertechnectate (Na 99m TcO 4 ) as radiotracer with other conventional techniques. The results were used for the calibration of the expanded Streeter and Phelps model of the river. In the work, the methodology and the main results obtained during the journey realized between the second fortnight of March and the first of April 2009 are presented. (Author)

  17. Impurity analysis in EC-99mTC radiotracer using chromatographic techniques

    International Nuclear Information System (INIS)

    Almeida, E.V.; Fukumori, N.T.O.; Mengatti, J.; Silva, C.P.G.; Matsuda, M.M.N.

    2008-01-01

    The objective of this study was to develop two chromatographic methods of impurity analysis in radiotracer 99m Tc-EC: the Thin Layer Chromatography (TLC) and the High Performance Liquid Chromatography Reversed Phase (HPLC-RP)

  18. Study of dilution of effluent discharged through a sea outfall near Mangalore using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.

    1987-01-01

    The fate of effluent discharged into water bodies is a matter of concern from the point of view of environmental pollution. Radiotracer techniques have been successfully used to study the change in concentration of effluents while being mixed with large water bodies. The technique used is to add a known concentration of radioactive tracer into the effluent stream and to measure the dilutions at different locations near the effluent discharge point with radiation detectors. M/s Mangalore Chemicals and Fertilizers Ltd (MCF) at Mangalore on the west coast of India disposes off the treated and initially diluted effluent at the rate of about 360 m 3 /h into the sea near by through an outfall extending about 100 meters into the sea. The effluent mainly contains ammonia in the range of 40-50 ppm as the pollutant. It was desired to measure the extent of dilution occurring to the effluent at a few locations of known distances along the sea shore from the discharge point of the effluent. Radiotracers 82 Br as ammonium bromide solution and tritium as tritiated water were employed for the study. The concentration measurement was done at site for 82 Br and by estimation of samples in the laboratory in the case of tritium. Dilution of the order of 1000 was obtained at about 100 meters distance for a continuous injection of about 4 hours. (author). 3 tables, 3 figures

  19. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Shenoy, K T; Sreenivas, T

    2015-03-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40-60MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Advanced CFD and radiotracer techniques - A complementary technology - for industrial multiphase applications

    International Nuclear Information System (INIS)

    Tu, J.Y.

    2004-01-01

    A CFD and RTD Education Package was developed, in which lecture notes, tutorials and computer softwares for both CFD and RTD are included. A user-friendly web-based interface has been prepared to allow lecturers more effectively conducting their training courses or workshops, and to provide students or users more easily learning the CFD and RTD knowledge and practising computer softwares. This report gives an overview of the advances in development and use of CFD models and codes for industrial, particularly multiphase processing applications. Experimental needs for validation and improvement of CFD models and softwares are highlighted. Integration of advanced CFD modelling with radiotracer techniques as a complementary technology for future research and industrial applications is discussed. The features and examples of the developed CFD and RTD Education package are presented. (author)

  1. Radiotracer studies for coastal zone management

    International Nuclear Information System (INIS)

    Hughes, C.; Kluss, T.; Airey, P.

    2001-01-01

    Coastal engineers and coastal zone managers increasingly rely on numerical models of fluid, sediment and contaminant dynamics. These are used to underpin coastal structure design and to predict environmental response to specific events such as storms or pollutant spills, and gradual changes such as sea-level rise or changes in bathymetry. Radiotracer techniques can be used to provide dynamic data on the movement of a specific patch of water, sediment or pollutant over time, which can be compared with model predictions. Two case studies are presented where radiotracer studies were used to improve confidence in numerical models of: (1) 2D hydrodynamics and sediment transport at the Port of Songkhla, Thailand; and (2) 3D hydrodynamics and algal bloom transport in Manila Bay, Philippines

  2. Studies on sorption of cadmium (II) ions onto Haro river sand from aqueous media using radiotracer and voltammetric techniques

    International Nuclear Information System (INIS)

    Ahmed, R.; Hasany, S.M.; Yamin, T.; Ansari, M.S.

    2006-01-01

    Sorption of Cd(II) ions on Haro river sand has been studied using radiotracer technique. The effects of pH and acid concentrations on the sorption were studied. The sorption increases with pH. reaches a maximum at pH 7 and decreases at higher pH values. With acids, it was found that sorption decreases with increasing acid concentration, and for more oxidizing acids sorption was less. Kinetic studies indicate that mostly intra particle diffusion occurs with first order rate constant of 18.45 x 10 -2 min -1 . The sorption data follow the Freundlich and Dubinin-Radushkevich (D-R) isotherms. In addition to the radiotracer method, voltammetric technique was applied and the results by the two techniques are in good agreement. The sorption free energy value indicates that adsorption process is chemisorption. The effect of temperature was studied and values of ΔH, ΔS and ΔG for Cd(II) have been calculated which are 20.15 kJ mol -1 , 74.04 J mol -1 K -1 and -1.754 kJ mol -1 . Adsorption of Cd(II) on Haro river sand is endothermic, spontaneous and entropy driven. The effect of different anions and cations at different concentrations was studied. Levels of cadmium have been monitored in water and sediments. (orig.)

  3. Radiotracer residence time distribution method for industrial and environmental applications. Material for education and on-the-job training for practitioners of radiotracer technology

    International Nuclear Information System (INIS)

    2008-01-01

    The International Atomic Energy Agency (IAEA) plays a major role in facilitating the transfer of the radiotracer technology to developing Member States. The major radiotracer techniques have been implemented through IAEA technical cooperation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for the education of specialists in different fields of nuclear technologies. This training course material is intended for the cultivation of radiotracer specialists and for continuing technical education of radiotracer practitioners worldwide. The wide interest in radiotracer technology has created the need for high level professional education and training in this field, which are not necessarily covered by traditional university courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Besides educational purposes, this publication will assist developing Member States in establishing their quality control and accreditation systems. This publication is based on lecture notes and practical works delivered by many experts in IAEA-supported activities. Lectures, papers, case studies and software were reviewed by a number of specialists in several meetings

  4. Development and applications of radiotracers technologies and gamma scanning

    International Nuclear Information System (INIS)

    Conejo, Mario; Chaverri, Oscar; Chine, Bruno; Vargas, Celso

    2008-01-01

    The radiotracers and gamma scanning technologies are very consolidated tools for studying, analyzing and evaluating of industrial processes. The development and the results of radiotracers and gamma scanning technologies applied in laboratory and more complex systems, are reported. The radiotracers technology was used to study boron diffusion during the curing process of the wood, to evaluate a lagoon of sewage treatment with aquatic iris plants and to carry out experimental work with controlled variables in a laboratory hydraulic circuit (flow rig). The gamma scanning technique was used to analyze a pilot tower in the laboratories. The main results achieved with the experiments were the following: 1) the boron absorption as a wood curing agent depends on the section of wood exposed to the curing solution; 2) during the tests effectuated with Iodine 131, the aquatic iris plants situated in the water treatment lagoon absorb part of the radiotracer, making difficult the residence time determination; 3) the sensibility of the system Cesium 137 source and detector is sufficiently high and can detect low radioactive absorption materials, situated inside columns with steel walls. (author) [es

  5. Radiotracers for medical applications

    International Nuclear Information System (INIS)

    Rayudu, G.A.S.

    1983-01-01

    This book discusses the medical applications of radiotracers. Diagnostic uses and pharmacokinetics of isotopes and radiopharmaceuticals is emphasized. The volume one covers the following topics: Radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; /sup 11/C, /sup 13/N, /sup 15/O, /sup 67/Ga. /sup 111/In, /sup 75/Se, /sup 123m/Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented. 272 pp., 7 x 10, 1983, ISBN-0-8493-6016-1

  6. Radiotracer properties determined by high performance liquid chromatography: a potential tool for brain radiotracer discovery

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Lewsey, James; Dewar, Deborah; Pimlott, Sally L.

    2012-01-01

    Introduction: Previously, development of novel brain radiotracers has largely relied on simple screening tools. Improved selection methods at the early stages of radiotracer discovery and an increased understanding of the relationships between in vitro physicochemical and in vivo radiotracer properties are needed. We investigated if high performance liquid chromatography (HPLC) methodologies could provide criteria for lead candidate selection by comparing HPLC measurements with radiotracer properties in humans. Methods: Ten molecules, previously used as radiotracers in humans, were analysed to obtain the following measures: partition coefficient (Log P); permeability (P m ); percentage of plasma protein binding (%PPB); and membrane partition coefficient (K m ). Relationships between brain entry measurements (Log P, P m and %PPB) and in vivo brain percentage injected dose (%ID); and K m and specific binding in vivo (BP ND ) were investigated. Log P values obtained using in silico packages and flask methods were compared with Log P values obtained using HPLC. Results: The modelled associations with %ID were stronger for %PPB (r 2 =0.65) and P m (r 2 =0.77) than for Log P (r 2 =0.47) while 86% of BP ND variance was explained by K m . Log P values were variable dependant on the methodology used. Conclusions: Log P should not be relied upon as a predictor of blood-brain barrier penetration during brain radiotracer discovery. HPLC measurements of permeability, %PPB and membrane interactions may be potentially useful in predicting in vivo performance and hence allow evaluation and ranking of compound libraries for the selection of lead radiotracer candidates at early stages of radiotracer discovery.

  7. A philosophy for CNS radiotracer design.

    Science.gov (United States)

    Van de Bittner, Genevieve C; Ricq, Emily L; Hooker, Jacob M

    2014-10-21

    Decades after its discovery, positron emission tomography (PET) remains the premier tool for imaging neurochemistry in living humans. Technological improvements in radiolabeling methods, camera design, and image analysis have kept PET in the forefront. In addition, the use of PET imaging has expanded because researchers have developed new radiotracers that visualize receptors, transporters, enzymes, and other molecular targets within the human brain. However, of the thousands of proteins in the central nervous system (CNS), researchers have successfully imaged fewer than 40 human proteins. To address the critical need for new radiotracers, this Account expounds on the decisions, strategies, and pitfalls of CNS radiotracer development based on our current experience in this area. We discuss the five key components of radiotracer development for human imaging: choosing a biomedical question, selection of a biological target, design of the radiotracer chemical structure, evaluation of candidate radiotracers, and analysis of preclinical imaging. It is particularly important to analyze the market of scientists or companies who might use a new radiotracer and carefully select a relevant biomedical question(s) for that audience. In the selection of a specific biological target, we emphasize how target localization and identity can constrain this process and discuss the optimal target density and affinity ratios needed for binding-based radiotracers. In addition, we discuss various PET test-retest variability requirements for monitoring changes in density, occupancy, or functionality for new radiotracers. In the synthesis of new radiotracer structures, high-throughput, modular syntheses have proved valuable, and these processes provide compounds with sites for late-stage radioisotope installation. As a result, researchers can manage the time constraints associated with the limited half-lives of isotopes. In order to evaluate brain uptake, a number of methods are available

  8. Current status and trends of cooperation on radiotracer and NCS technologies

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency, Vienna (Austria). Industrial Applications and Chemistry Section

    1997-10-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on `Radiotracer technology for engineering unit operations studies and unit process optimisation` aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on `Multibeam radiogauging for multi-phase systems studies` to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  9. Current status and trends of cooperation on radiotracer and NCS technologies

    International Nuclear Information System (INIS)

    Thereska, J.

    1997-01-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on 'Radiotracer technology for engineering unit operations studies and unit process optimisation' aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on 'Multibeam radiogauging for multi-phase systems studies' to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  10. A built-in radiotracer (24Na) for measuring circulation catalyst rates

    International Nuclear Information System (INIS)

    Domondon, D.B; Berbano, M.C.

    1975-01-01

    A local petroleum refinery intended to calibrate its catalyst flow measuring instrument (propeller blade) using the radioactive tracer technique (RTT). For this purpose, a method of incorporating a suitable radiotracer in commercial catalyst beads had to be found. Two methods of labelling are described. One method involved the incorporation of the radiotracer in a gel of the same composition as the commercial catalyst and subsequent conversion of the gel into a from like that of the commercial catalyst beads. Another method utilized the strong adsorptive properties of the commercial catalyst beads for the chosen isotopes, e.g., 144 Cs, 46 Sc. To effect quantitative adsorption, commercial catalyst beads were simply stirred in a slightly acidic (pH4) chloride solution of the radiotracers for some time. The radiotracers were found to distribute almost uniformly over the entire catalyst surface and no evidence of volatilization of the isotopes from the catalyst surface under condition of use in commercial units was observed. Another probable method was suggested by the Research and Development Division, Philippine Atomic Energy Commission. Aluminium is a major component of the ceramic catalyst beads and sodium is present as impurity. Hence, a radiotracer ( 24 Na) can be formed in the beads by the reaction 23 Na (n,gamma) 24 Na, 27 Al (n,alpha) 24 Na. This possible method of simply irradiating the commercial catalyst beads in the reactor thereby inducing the radiotracer. 24 Na in situ fulfils all the criteria for the selection of an appropriate radiotracer. The method is very simple but reliable

  11. The heritage of radiotracers for PET

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1988-01-01

    The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology. 54 refs

  12. Industrial applications of radiotracer and sealed source technology promoted by IAEA

    International Nuclear Information System (INIS)

    Joon-Ha Jin; Thereska, J.

    2004-01-01

    Great technical and economical benefits can be obtained by applying radioisotope technologies to various industries. The International Atomic Energy Agency (IAEA) has contributed to the development of radiotracer and sealed source technology as applied to industry and environment through coordinated research projects (CRPs). The mature and competitive techniques have been transferred and implemented to developing countries through the Agency's technical co-operation (TC) projects. The paper presents the main achievements in radiotracer and sealed source technology promoted by IAEA as well as the perspective of the technology transfer to developing countries. (author)

  13. Radiotracer injector: An Industrial Application (RIIA)

    International Nuclear Information System (INIS)

    Noraishah Othman; Mohd Arif Hamzah; Fadil Ismail; Nurliyana Abdullah

    2011-01-01

    The radiotracer injector is meant for transferring liquid radiotracer in the system for industrial radiotracer application with minimal radiation exposure to the operator. The motivation of its invention is coming from the experience of the workers who are very concern about the radiation safety while handling with the radioactive source. The idea ensuring the operation while handling the radioactive source is fast and safe without interrupting the efficiency and efficacy of the process. Thus, semi automated device assisting with pneumatic technology is applied for its invention. (author)

  14. Radiotracer techniques in mineral processing

    International Nuclear Information System (INIS)

    Przewlocki, K.

    1991-01-01

    The value of the smelter metal content in currently exploited polymetallic ores mostly does not exceed 2%. Before metallurgical treatment, ore must pass through the concentration process. The benefication process usually starts from the comminution of excavated material and terminates at the flotation and drying of the concentrate. These operations consume vast quantities of energy. To be economically justified, the process requires optimization and, if possible, automatic control. Radioactive tracers were found to be useful in the identification of particular technological subsystems and their subsequent optimization. A great deal of experience has been gathered in this field so far. The industrial radiotracer test (RTT) is carried out using very sensitive multidetector recording systems which have digital data acquisition capabilities. The optimization strategy consists of periodically adjusting technological process and set points of controlled variables according to certain improvement procedures. If computer facilities are available, data interpretation and calibration of the mathematical models describing the technical process itself can be performed on the spot. This significantly accelerates the whole procedure as RTT may be repeated for particular system configurations. The procedure of plant optimization by means of RTT is illustrated in the paper using the example of the copper ore enrichment process, assuming that it is representative of the whole mineral industry. Identification by RTT of the three main operations involved in the ore enrichment process, such as comminution, flotation and granular classification, is discussed in detail as particular case studies. In reference to this, it is also shown how the technological process can be adjusted to be most efficient. (author). 14 refs, 7 figs

  15. Radiotracer experiments and CFD simulation for industrial hydrocyclone performance

    International Nuclear Information System (INIS)

    Stegowski, Z.; Nowak, E.

    2007-01-01

    Hydrocyclone is a device for solid concentration or selection of solid particles from a liquid-solid mixture. It is widely used in the mineral industry for selection of solid particles from a few to a few hundred micrometers. This paper presents a radiotracer experiment and computational simulation of selection of solid particles in a hydrocyclone of Φ-500 μm, which is used in the industrial copper ore concentration process. The simulation, based on computational fluid dynamics (CFD) techniques, allowed obtaining the velocity and concentration distribution for a real mixture flowing in the hydrocyclone. The mixture was composed of water and nine solid phases of different grain sizes. Finally, the selection curve of solid grains was obtained and compared with the experimental radiotracer results. (author)

  16. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, Jose; Damera Martinez, A.; Ramos Espinosa, K.

    2003-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one a modified SRI, both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented Several trials performed simultaneously at the two Clarifiers demonstrated that the modified SRI was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The non-availability of a flow meter did not allow to extract more information related to some pattern flux anomalies, nevertheless, the radiotracer method was able to detect certain differences between the two clear juice outlet of the modified SRI Clarifier, probably due some problems in the construction of this equipment. This fact so as other goals achieved in this work, show once more the potentiality of the radiotracer method for this type of study related to the hydrodynamic characteristics of industrial facilities. (Author)

  17. Isotope techniques in non-destructive testing of dynamic systems

    International Nuclear Information System (INIS)

    Singh, Gursharan; Pant, H.J.

    1996-01-01

    A few applications of gamma scanning and radiotracer techniques for Non-destructive Testing (NDT) of dynamic systems in chemical and petrochemical industries are briefly discussed in this paper. Examples of gamma scanning inspections carried out for troubleshooting of various types of columns such as vacuum, extraction, separator and rectifier, with trays and packed beds and having diameters from 1 meter to 8.4 meters are given. Radiotracer applications for Residence Time Distribution (RTD) studies on different systems like an aniline production reactor in a chemical industry and a laboratory scale solid-liquid fluidized bed column are mentioned. (author)

  18. Application of centrifuge modelling and radiotracers to migration studies of buried toxic waste

    International Nuclear Information System (INIS)

    Villar, H.P.

    1995-01-01

    A new technique to study the migration of souble waste components in soils, based on the application of centrifugue modelling and of selected short-lived radiotracers, is presented. The technique is based on the acceleration of the migration proceses of a specific tracer in a soil model, with simple and well-established scaling laws being used to interpret the results. The use of radiotracers allows geat flexibility and the adoption of a wide range of concentrations. Demosntrations of the technique have been carried out with two elements of radically distinct behaviour: iodine noted for its mobility in soils, and thallium, which tends to be strongly sorbed. Two different soil types have been used. The results semed to confirm what is known about the behaviour of both elements, so that the feasibility of the technique for such studies has been concluded. (author). 7 refs, 4 figs, 1 tab

  19. Experimental observation of silver and gold penetration into dental ceramic by means of a radiotracer technique

    International Nuclear Information System (INIS)

    Moya, F.; Payan, J.; Bernardini, J.; Moya, E.G.

    1987-01-01

    A radiotracer technique was used to study silver and gold diffusion into dental porcelain under experimental conditions close to the real conditions in prosthetic laboratories for porcelain bakes. It was clearly shown that these non-oxidizable elements were able to diffuse into the ceramic as well as oxidizable ones. The penetration depth varied widely according to the element. The ratio DAg/DAu was about 10(3) around 850 degrees C. In contrast to gold, the silver diffusion rate was high enough to allow silver, from the metallic alloy, to be present at the external ceramic surface after diffusion into the ceramic. Hence, the greening of dental porcelains baked on silver-rich alloys could be explained mainly by a solid-state diffusion mechanism

  20. Radiotracers in medical applications, vols 1-2

    International Nuclear Information System (INIS)

    Rayudu, G.V.S.

    1983-01-01

    These volumes will serve as a basis for instruction and reference for professionals such as radiopharmaceutical chemists, radiopharmacologists, radiopharmacists, radiobiochemists, and others involved in the medical applications of radiotracers. Vol. I: Topics include radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; 11 C, 13 N, 15 O, 67 Ga. 111 In, 75 Se, /SUP 123m/ Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented

  1. Regulatory requirements for fluorine 18-labelled radiotracers

    International Nuclear Information System (INIS)

    Prigent, A.

    2005-01-01

    Although European and French regulations define radiopharmaceuticals and their different conditions for use, there is no legal status of the radiotracer. Radiotracer is commonly known as a molecular entity administered in tracer doses, that means at very low masses (e.g., nano-mol amounts) and, consequently, without any pharmacological effect. A radiotracer can meet the specifications of either a radiochemical (usually restricted to research in animal models) or a radiopharmaceutical (human use for diagnostic imaging or research projects). Besides the 'proprietary medicinal product', different status have been defined to allow other uses in humans, referring to 'magistral formula' preparation, 'officinal formula' preparation, investigational medicinal product for clinical trials, or to a radiopharmaceutical with a 'patient named authorization'. However, because of the short half-life of fluorine 18 and expanding development of molecular imaging techniques using positron emission tomography (PET), the current regulation is sometimes considered as inappropriate with regard to the small-size production required for such on-site manufactured radiopharmaceuticals. It is often claimed that it could be very difficult to comply with the current Good Manufactured Practice (cGMP). As previously done for radiopharmaceuticals based on monoclonal antibodies, specific adjustments for PET radiopharmaceuticals are under discussion and the 'note for guidance on radiopharmaceuticals' will be soon revised by the Committee for Medicinal Products for Human Use (CHMP) of the European Medicines Agency (EMEA). In many cases, a status of 'magistral' product might be attributed to a PET radiopharmaceutical manufactured according with European Pharmacopoeia monographs. (author)

  2. Characterization of electrochemical cell for production of radiotracer in organic medium

    International Nuclear Information System (INIS)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da; Coordenacao de Pos-Graduacao e Pesquisa de Engenharia

    2017-01-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  3. Characterization of electrochemical cell for production of radiotracer in organic medium

    Energy Technology Data Exchange (ETDEWEB)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da, E-mail: hkenup@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-11-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  4. Determination of retention period of sewage in a filtration plant using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1979-01-01

    A radiotracer investigation was carried out at Dadar sewage purification plant, Bombay, for measuring the retention period of a trickling filter unit. The method is based on the addition of 82 Br tracer in the form of NH 4 Br solution at the inlet and continuous recording of the tracer at the flow stream. Results obtained in the actual investigation are also given. (auth.)

  5. A radiotracer technique for testing a high pressure gas compressor for oil leakage

    International Nuclear Information System (INIS)

    Eapen, A.C.; Kirti; Jain, S.K.; Gupta, P.P.

    1979-01-01

    The radiotracer investigations carried out at NOCIL, Bombay, to measure the amount of lubrication oil present in the gas being compressed in a 1000 H.P. centrifugal compressor are described. By injecting a few mCi 131 I labelled glyceryl trioleate tracer and monitoring the radioactivity of the outlet gas for about 20 hours, the extent of the oil present in the gas could be determined. (auth.)

  6. Recoil generated radiotracers in studies of molecular dynamics

    International Nuclear Information System (INIS)

    Spicer, L.D.

    1981-01-01

    This chapter summarizes many of the contributions that the recoil technique of generating excited radiotracer atoms in the presence of a thermal environment is making to the field of chemical dynamics. Specific topics discussed critically include characterization of the generation and behavior of excited molecules including fragmentation kinetics and energy transfer, measurement of thermal and hot kinetic parameters, and studies of reaction mechanisms and stereochemistry as a function of reaction energy. Distinctive features that provide unique approaches to dynamical problems are evaluated in detail and the complementarity with more conventional techniques is addressed. Prospects for future applications are also presented

  7. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  8. Differential zinc uptake of rice genotypes as established by radiotracer technique

    International Nuclear Information System (INIS)

    Sudhalakshmi, C.; Krishnasamy, R.; Meena, S.

    2017-01-01

    Rice is a sensitive crop to zinc (Zn 2+ ) deficiency and its uptake, transport and metabolism is imperative in bio-fortification process. A pot culture experiment was conducted at Tamil Nadu Agricultural University, Coimbatore to establish the differential zinc use efficiency of rice genotypes viz., Zn efficient Norungan and Zn inefficient PMK 3 and to assess the partitioning of Zn in shoot and root of genotypes employing radiotracer technique. Graded levels of Zn (0, 12.5, 25.0, 37.5 and 50 kg ha -1 of ZnSO 4 ) as 65 Zn labeled ZnSO 4 were applied. Zinc uptake from fertilizer increased with increased dose of applied zinc up to 37.5 kg ha -1 for PMK 3 whereas in Norungan, it was up to 25 kg ZnSO 4 ha -1 and thereafter it declined. The per cent zinc derived from fertilizer (% Zndff) was the highest in PMK 3 which apparently implies its inability to mobilize soil nutrient reserve and respond to elevated doses of applied zinc. The % Zndfs was higher in Norungan. In both the genotypes, the 'A value' showed a conspicuous increase with increased dose of applied zinc. Norungan registered a higher 'A value' than PMK 3 irrespective of the stages of sampling. Zn efficient Norungan had better Zn translocation to the shoots whereas in Zn inefficient PMK 3, vacuolar sequestration in root cells was higher. (author)

  9. Accelerated Solvent Extraction: An Innovative Sample Extraction Technique for Natural Products

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Azfar Hanif Abd Aziz; Rosniza Razali

    2015-01-01

    Accelerated solvent extraction (ASE) is one of the novel techniques that have been developed for the extraction of phytochemicals from plants in order to shorten the extraction time, decrease the solvent consumption, increase the extraction yield and enhance the quality of extracts. This technique combines elevated temperatures and pressure with liquid solvents. This paper gives a brief overview of accelerated solvent extraction technique for sample preparation and its application to the extraction of natural products. Through practical examples, the effects of operational parameters such as temperature, volume of solvent used, extraction time and extraction yields on the performance of ASE are discussed. It is demonstrated that ASE technique allows reduced solvent consumption and shorter extraction time, while the extraction yields are even higher than those obtained with conventional methods. (author)

  10. Radiological protection in the use of radiotracers in industrial process

    International Nuclear Information System (INIS)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Thomé, Z.D.

    2017-01-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  11. Radiological protection in the use of radiotracers in industrial process

    Energy Technology Data Exchange (ETDEWEB)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C., E-mail: mara@cnen.gov.br, E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  12. Synthesis of new technetium brain radiotracers

    International Nuclear Information System (INIS)

    Ben Dhieb, Fatma

    2012-01-01

    The scintigraphic diagnosis is a major mean for detecting neuro degenerative diseases at early stage; this requires specific radiotracers to a particular class of brain receptors. Our goal was the synthesis of radiotracers, cytectrenes derivatives, which are specific to the 5-HT1A receptor, whose dysfunction is an indicator of neuro degeneration. The study of their biodistribution revealed for only one of them, a good brain retention and a retrieval adequate for diagnosis.

  13. Radiotracer studies of fungicide residues in food plants

    International Nuclear Information System (INIS)

    1990-04-01

    Agricultural fungicides are chemicals used on seeds, crops and in soils throughout the growing season. Fungicide treatments may lead to various levels of chemical residues in food commodities. Primary emphasis has been placed on ethylenebisdithiocarbamates (EBDCs), an important group of agrofungicides used in preparations for spraying or dusting major crops such as apples, pears, broccoli, cabbages, egg plants, cauliflower, grapes, lettuce, peppers, celery, cucumbers and tomatoes. Treatments with EBDCs result in terminal residues containing ethylenthiourea (ETU). This is a toxicologically significant decomposition product which has attracted considerable attention in recent years due to indications of its potential goitrogenic and carcinogenic properties. In recognition of the need for a coordinated examination of ETU levels in food, particularly under tropical conditions, the program of radiotracer techniques as a tool for studying fungicide residue problems on food was initiated in 1984. In current studies, three EBDCs, maneb, zineb and mancozeb from different manufacturers in different countries were analysed. This report describes the model protocols (Annexes I, II and III) as they were set up for determination of residues in commodities and soil, using radiotracer and conventional chromatographic techniques . In the 16 papers presented in this report C 14 -labelled EBDCs are determined in plants, vegetables, and soils, before and after cooking, as a function of time and of other agricultural parameters. Refs, figs and tabs

  14. Radiotracers inside the system

    International Nuclear Information System (INIS)

    Savio, Eduardo

    2000-01-01

    The radioactive use of a tracer that you incorporated in a biological, physical or chemicals system can be an indicator of some of the following situations: of the system in general, of a property that is wanted to evaluate, of a biochemical, physiological or pathophysiological. One the radiotracers use inside the system presents the following advantages: 1. it is possible to detect them and to measure them with high precision and sensibility, 2. the radioactivity is independent of the pressure, the temperature, the physical or chemical state 3. the radiotracers do affect the system and they can be used as non destructive methods 4. In most of the cases they can be measured in independent form of the matrix, without necessity of a calibration curve

  15. Principles of radiotracer methodology

    Energy Technology Data Exchange (ETDEWEB)

    Kisieleski, W.E.

    1975-06-01

    Information is presented on the properties of radioisotopes and radiations, methods and equipment for radiation detection, safety in handling radioactive materials, the biological effects of radiation, and the design of radiotracer studies. (LCL)

  16. Bioavailability and distribution and of ceria nanoparticles in simulated aquatic ecosystems, quantification with a radiotracer technique

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Zhang Peng; He Xiao; Ma Yuhui; Lu Kai; Zhao Yuliang

    2014-01-01

    Although the presence of manufactured nanoparticles in the aquatic environment is still largely undocumented, their release could certainly occur in the future, particularly via municipal treatment plant effluents of cities supporting nano-industries. To get an initial estimate of the environmental behavior of nanomaterials, we investigated the distribution and accumulation of ceria nanoparticles in simulated aquatic ecosystems which included aquatic plant, shellfish, fish, water, and sediment using a radiotracer technique. Radioactive ceria ( 141 CeO 2 ) nanoparticles with a diameter of ca. 7 nm were synthesized by a precipitation method and added to the simulated aquatic ecosystems. The results indicate that the concentration of ceria nanoparticles in water decreased to a steady-state value after 3 days; meanwhile, the concentrations of ceria nanoparticles in the aquatic plant and sediment increased to their highest values. The distribution and accumulation characteristics of ceria nanoparticles in various aquatic organisms were different. Ceratophyllum demersum showed a high ability of accumulation of ceria nanoparticles from water. (authors)

  17. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique

    International Nuclear Information System (INIS)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J.; Biswal, Jayashree; Sharma, Vijay K.; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K.; Rao, S. Madhukar; Dash, A.

    2016-01-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. - Highlights: • Radiotracer experiments were conducted to measure RTD of liquid phase in a pulp digester • Mean residence times of white liquor were measured • Axial dispersion and tanks-in-series models were used to investigate flow patterns • Parallel flow paths were observed in first section of the digester • Optimized flow rates of biomass and liquor were obtained

  18. Development Of 12 Head GAMMA Detection And Graphical Presentation Software Suitable For Industrial Process Investigation By Radiotracer Technique

    International Nuclear Information System (INIS)

    Saengchantr, Dhanaj; Chueinta, Siripone

    2009-07-01

    Full text: Data logging with prompt graphical presentation software accommodating gamma radiation signals from 12 scintillation detectors through standard RS-232 interface has been developed. Laboratory testing by detection of injected-mixed radioactive tracer in a fluid flowing inside a pipe was conducted. The radioactive mixed fluid passed through the detectors located at several points along the pipe and the generated signals correspond to the mass flow inside the pipe were recorded. Up to 10,000 data points of fast (20 millisecond) dwell time could be accumulated. Graphical presentation allowed fast interpretation while the output data were suitable for more accurate evaluation with standard software e.g. Residence Time Distribution (RTD), Computed Tomography Visualization. Further utilization in the industry, in conjunction with radiotracer techniques, for troubleshooting and process optimization will be further carried out

  19. Utility of radiotracer methodology in scientific research of industrial relevancy

    International Nuclear Information System (INIS)

    Kolar, Z.I.

    1990-01-01

    Utilization of radiotracer methodology in industrial research provides substantial scientific rather than directly demonstrable economic benefits. These benefits include better understanding of industrial processes and subsequently the development of new ones. Examples are given of the use of radiotracers in technological studies and the significance of the obtained results is put down. Creative application of radiotracer methodology may contribute to the economic development and technological advancement of all countries including the developing ones. (orig.) [de

  20. Axial dispersion, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column by radiotracer residence time distribution analysis.

    Science.gov (United States)

    Din, Ghiyas Ud; Chughtai, Imran Rafiq; Inayat, Mansoor Hameed; Khan, Iqbal Hussain

    2008-12-01

    Axial dispersion, holdup and slip velocity of dispersed phase have been investigated for a range of dispersed and continuous phase superficial velocities in a pulsed sieve plate extraction column using radiotracer residence time distribution (RTD) analysis. Axial dispersion model (ADM) was used to simulate the hydrodynamics of the system. It has been observed that increase in dispersed phase superficial velocity results in a decrease in its axial dispersion and increase in its slip velocity while its holdup increases till a maximum asymptotic value is achieved. An increase in superficial velocity of continuous phase increases the axial dispersion and holdup of dispersed phase until a maximum value is obtained, while slip velocity of dispersed phase is found to decrease in the beginning and then it increases with increase in superficial velocity of continuous phase.

  1. Design and evaluation of radiotracers for determination of regional cerebral blood flow with PET

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Duncan, C.C.; Shiue, C.Y.

    1982-01-01

    The tracer kinetics of 4-Fluoro( 18 F)-, 4-Bromo( 82 Br)- and 4-Iodo( 125 I)-antipyrine and 15 O-water were compared in a cat or baboon animal model. First-pass cerebral extraction and clearance with alterations in PaCO 2 were measured for whole brain. The Renkin/Crone model was used to evaluate brain capillary permeability-surface area product for 4- 18 FAP in cats. Positron-emission-tomographic measurements required development of an instrument and technique for control of the arterial concentration of the radiotracer as a ramp function, so that tracer concentration changes due to radioactive decay or altered physiological processes could be accurately described with PET. Pharmacokinetic and tissue-distribution studies in cats were used to determine dosimetry for 4- 18 FAP. 4-Bromoantipyrine labeled with 78 Br (t = 6.5 m) is suggested as a tracer for determination of rCBF with PET

  2. Mechanism of action in VIVO of some pet radiotracers

    International Nuclear Information System (INIS)

    Sachinidis, J.J.; Egan, G.F.; Berlangieri, S.U.; Scott, A.M.

    1998-01-01

    Full text: Position Emission Tomography (PET) is a technique that utilises position-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. PET studies range from standard image displays that provide indices of physiological function to complex kinetic analysis methods for absolute quantification. This paper will review some of the important PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre, Melbourne and discuss their mechanism of action in vivo. Depending on their mechanism of action, PET radiopharmaceuticals may be divided into two categories. The first category is non-specific radiotracers which follow a biochemical pathway. The second category is specific radioligands which are involved in an interaction with a receptor transporter or a receptor site. Radiopharmaceuticals from the first category may be assessed using a single or two compartmental plasma-tissue model and allow a measurement of tissue extraction or metabolism.[ 15 O] water is a freely diffusable inert which is used for cerebral blood flow measurement; [ 18 F] FDG which follows the initial phases of glucose metabolism but does not enter the Krebs cycle after phosphorylation and therefore is effectively trapped in the cells, can be used for tissue glucose metabolism measurement in oncology, cardiology and neurology; and [ 18 F]fluoromisonidazole which is a bio-reductive drug that in vivo follows an intracellular reduction pathway, can be used for hypoxic tissue measurement in stroke and tumour evaluation. Radiopharmaceuticals from the second category may be assessed using a three-compartment model: - unmetabolised free ligand in plasma, - free ligand in tissue, - and specially bound ligand in tissue. These radiotracers such as [ 11 C] flumazenil, which is an antagonist with high affinity and selectivity for a central benzodiazepine receptors, are used to study the changes in density or affinity of these receptors

  3. Use of Radiotracers to Study Surface Water Processes

    International Nuclear Information System (INIS)

    2015-03-01

    This publication represents a sound knowledge base for the conduct of radiotracer studies in the environment, with papers on radiotracer methodology, radiation protection and regulation, data analysis and modelling. Environmental case histories from five Member States - Australia, Brazil, France, the Republic of Korea and Sweden - provide information on conducting studies involving he use of radioactive tracers. These case histories are not meant as guidelines for preparing a field study but can rather serve as examples of the type, caution and extent of work involved in environmental studies using radiotracers. This publication can provide guidance for conducting potential future training events in the use of radioactive traces in the environment and can serve as a key reference to all concerned directly with surface water processes

  4. Combination of sealed source and radiotracer technique to understand malfunctioning in a chemical plant

    Energy Technology Data Exchange (ETDEWEB)

    Yelgaonkar, V.N. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)], E-mail: vivekyel@rediffmail.com; Jayakumar, T.K.; Singh, Sudhir; Sharma, M.K. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)

    2009-07-15

    Pure terphthalic acid (PTA) is produced by the oxidation of paraxylene in an oxidation reactor of a PTA plant. Since the reaction is exothermic, the temperature rises above 210 deg. C. Vapours formed in the reactor are passed through a series of heat exchangers and the cooled liquid is fed back to the reactor, which flows to the reactor by gravity. In one of the heat exchangers, improper flow distribution in the inlet and outlet pipelines was suspected. Maldistribution of flow in the heat exchanger was also suspected. Gamma scanning of the pipelines and a radiotracer experiment were carried out in the heat exchanger to study the malfunctioning. A specially fabricated pipe scanner was used to scan both 24 in diameter and 16 in diameter pipelines. From gamma scanning of the pipelines mostly on the bends, absence of the full bore flow of the liquid was observed. Presence of vapours along with the liquid could be obstructing the liquid flow, thereby causing the malfunctioning. A radiotracer experiment was also carried out to study the flow pattern in the heat exchanger. From the experiment, mean residence time of the heat exchanger was estimated as 470 s, which theoretically should be about 102 s. It indicated that the flow is decelerated in the heat exchanger because of the presence of vapour lock in the tube side.

  5. The radiochemical purity of radiotracers as the criterion of their usefulness in investigations of hydrocarbons distillation

    International Nuclear Information System (INIS)

    Kolaczkowski, M.

    1976-01-01

    Among numerous analytic techniques of separation and analysis of radioactive products gas radiochromatography has proved to be particularly suitable. Organic bromides labelled with 82 Br-radionuclide are investigated. The analytic gas chromatographs equipped with appropriately constructed radiochromatographic attachments are used. The results of radiochemical purity determination of radiotracers are compared for various techniques. (author)

  6. Application of radiotracer technology to the study of coastal processes

    International Nuclear Information System (INIS)

    Airey, P.; Szymczak, R.; Zaw, M.; Tu, J.; Kluss, T.; Barry, J.

    1999-01-01

    Recent progress at ANSTO in the applications of radiotracer techniques to the study of coastal processes is reviewed. Tracers are used in detailed studies of specific components of complex environmental systems and are applied to the evaluation and extension of numerical models. Examples include studies of the aggregation of sewage particles following release from ocean outfalls. The use of tracers to study the impact of storm events on bedload transport at depth has also been demonstrated

  7. Investigation of flow behaviour of coat/ash particles in an advanced pressurised fluidized bed gasifier (APFBG) using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Vidhya Kamadu, M.; Prakash, S.G.; Krishanamoorthy, S.; Ramani, N.V.S.; Sonde, R.R.

    2004-01-01

    Knowledge of Residence Time Distribution (RTD), Mean Residence Time (MRT) and degree of backmixing of solid phase is important for efficient operation of the coal gasifier. Radiotracer technique was used for measure RTD of coal/ash particles in a pilot-scale gasifier and obtain the values of MRT and backmixing. Lanthanum 140 labeled coal (100 g) was used as a tracer. The tracer was instantaneously injected into the coal feed line and monitored at ash and gas outlets of the gasifier using collimated scintillation detectors. The measured RTD data were treated and MRTs of coal/ash particles were determined. The treated data were simulated using tank-in-series model. The simulation RTD data indicated good degree of mixing with minor bypassing/short-circulating of coal particles. The results of the investigation were found useful for scale-up of the gasification process. (author)

  8. The use of radiotracers in natural rubber research in Malaysia

    International Nuclear Information System (INIS)

    Lai, P.F.; Singh, M.M.

    1981-01-01

    Five main areas where radiotracers have been used in research on natural rubber are on studies on the uptake of plant nutrients by Hevea brasiliensis using 32 P, 86 Rb and 45 Ca as tracers; biosynthesis of Hevea rubber using 14 C or 3 H labelled intermediates; translocation and metabolism of 14 C. Ethephon in Hevea brasiliensis; use of radiotracers as analytical tools and adsorption of labelled fatty acid soaps on natural rubber lattices. These studies are discussed to show the powerful tool that radiotracers provide in agricultural, biochemical and chemical research on natural rubber. (author)

  9. Application of radiotracer methods in streamflow measurements

    International Nuclear Information System (INIS)

    Dincer, T.

    1967-01-01

    An attempt is made to evaluate methods using radiotracers in streamflow measurements. The basic principles of the tracer method are explained and background information given. Radiotracers used in stream discharge measurements are discussed and measurements made by different research workers are described. Problems such as adsorption of the tracer and the mixing length are discussed and the potential use of the radioisotopes as tracer in the routine stream-gauging work is evaluated. It is concluded that, at the present stage of development, radiotracer methods do not seem to be ready for routine use in stream-gauging work, and can only be used in some special cases. For gamma-emitting radioisotopes there are problems related to safety, transport and injection which should be solved. Tritium, though a very attractive tracer in some respects, has the disadvantages of having a relatively long half-life and of disturbing the natural tritium levels in the region. Finally, an attempt is made to define the objectives of the research in the field of application of radioisotopes in hydrometry. (author)

  10. A radiotracer method for the dynamic measurement of the in-process inventory of dissolved materials

    International Nuclear Information System (INIS)

    Iqbal, M.N.; Gardner, R.P.; Verghese, K.

    1990-01-01

    A radioactive tracer method and the associated mathematical models have been developed to determine the in-process inventory of zirconium in a pulse column from the counting rate data taken at the exits of the aqueous and organic phases after an impulse injection of the radiotracer at the aqueous-phase inlet. Model parameters were obtained by applying a nonlinear least-squares fitting of the models to the experimental data. The total inventory of zirconium present in the pulse column under different operating conditions was determined by calculating the average residence time of zirconium in the system using these model parameters. The results indicate that the radiotracer technique provides a viable means of on-line determination of solute mass holdup. (author)

  11. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique.

    Science.gov (United States)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J; Biswal, Jayashree; Sharma, Vijay K; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K; Rao, S Madhukar; Dash, A

    2016-05-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Synthesis of new radiotracers based on aniline

    International Nuclear Information System (INIS)

    Ayari, Issra

    2008-01-01

    There are several possible applications of radioactivity, we cite: the study of the functional and neurochirnical aspects related to the brain. This study requires the synthesis of specific radiotracers able to cross their target tissue. The synthesis methods need to be constantly updated to respond to the big demand of this domain. The development of the chemistry of metal complexes helped us to find a stable radiotracer based on aniline and marked with technetium. This stability aI 10wed us to realize a possible biodistribution and to envisage to count the radioactivity and to valid the radiopharmaceutical. (Author)

  13. Synthesis of new radiotracers for tuberculosis diagnosis

    International Nuclear Information System (INIS)

    Keskes, Badis

    2009-01-01

    Tuberculosis remains a worldwide health problem and its diagnosis presents a major challenge. The examinations currently employed are little appreciable and so far there is no reliable diagnosis test. These last years, the development of the new radiopharmaceuticals, referred to diagnosis, has revived interest in the search for new molecules with a tropism to a particular disease. Thanks to this field, which lies at the interface of organic and organometallic chemistry, nuclear medicine and biology, we have been led to synthesize a technetium radiotracer linked to isoniazid. For the identification of this radiotracer, we used its similar rhenium model. (Author)

  14. Synthesis of new radiotracers based of Ethyl Ester

    International Nuclear Information System (INIS)

    Trabelsi, Donia

    2008-01-01

    The in vivo study of a biochemical or physiological process requires the synthesis of specific radiotracers but also the targeting of these compounds so that they can reach their target tissue. Methodologies original synthesis associated with radioisotopes used, the quantities and chemical forms often have to be available developed. The chemistry of metal complexes booming, we were able to use the ethyl ester combined with technetium, forming a stable radiotracer. Finally, a counting of radioactivity in different rat's organs completed our study. (Author)

  15. [11C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    International Nuclear Information System (INIS)

    Wilson, Alan A.; Garcia, Armando; Parkes, Jun; Houle, Sylvain; Tong, Junchao; Vasdev, Neil

    2011-01-01

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([ 11 C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [ 11 C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [ 11 C]CURB was irreversibly bound to FAAH. Conclusions

  16. Blood circulation of the inner ear under the influence of medications. Radiotracer experiments using guinea pig cochlea

    International Nuclear Information System (INIS)

    Neumeier, A.

    1987-01-01

    The dependence of the blood circulation in the inner ear on various medications is discussed. By means of a radiotracer clearance technique the cochlear clearance curves for the guinea pig cochlea after the administration of various circulation stimulants were determined. (MBC) [de

  17. CFD simulation of homogenisation time measured by radiotracers

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostik, M.; Jahoda, M.

    2004-01-01

    A methodology for CFD (Computational Fluid Dynamics) simulation of radiotracer experiments was suggested. The most important parts of the methodology for validation of CFD results by radiotracers are: a) successful simulation of tracer experiment by CFD code (numerical solution of tracer dispersion in a stirred tank), which results in tracer concentration field at several time intervals; b) post-process data treatment, which uses detection chain description and which enables to simulate the detector measurement of homogenisation time from the tracer concentration field evaluated by CFD code. (author)

  18. Production of 41Ar and 79Kr gaseous radiotracers for industrial applications

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Jagadeesan, K.C.; Shivarudrappa, V.; Sharma, V.K.; Chitra, S.

    2007-01-01

    Radiotracers are extensively used in many industries for trouble shooting and optimization of process parameters leading to considerable savings in time and huge economic benefits. In chemical and petrochemical industries different gases and vapours flowing in the conversion reactors play a major role in the final production. Gaseous radiotracers are ideal to study hydrodynamics of gas phases in process vessels. 41 Ar and 79 Kr are the preferred gaseous radiotracers for such studies. Owing to the increase in demand from Indian industries for gas phase radiotracers, efforts have been made to produce 41 Ar and 79 Kr indigenously by irradiation of 40 Ar and enriched 78 Kr gaseous targets in research reactors. Prequalification of the containers used, safety aspects concerning accidental rupture and mandatory tests necessary for irradiation of gaseous targets in the reactors have been studied. The paper describes some of the important safety aspects involved and the results of trial irradiations on the production of 41 Ar and 79 Kr radiotracers. Standardization of suitable assay protocols for their regular production and supply for applications in industries is also described. (author)

  19. Use of radiotracers for studies of metal sorption behaviour

    International Nuclear Information System (INIS)

    McCubbin, D.; Leonard, K.S.

    1995-01-01

    Radiotracers provide a convenient tool to study the behaviour of metal ions and other contaminants in natural waters. Furthermore, the use of radiotracers in controlled laboratory experiments provides an ideal approach for investigating, in a systematic manner, the role of individual parameters on processes, at mass concentrations found in the environment. A simplistic procedure has been developed to produce a thorium radiotracer ( 234 Th), in a similar chemical form (non-acidic) to that of the aquatic medium under investigation, to determine the kinetics of sorption to marine particulate material. The benefit of this procedure is that the system is likely to be perturbed to a lesser extent by changes in pH and dissolved Th species following tracer addition. Results from filtering different tracer batches through membranes, to determine the sorption characteristics prior to use, indicate that the physico-chemical behaviour of individual batches was extremely variable. Not surprisingly, the amount of uptake immediately following tracer additions to solutions containing marine particulate material was also variable. It is suggested that the role of tracer may be underestimated if added in acid form. Nevertheless, having accounted for the initial sorption, the subsequent uptake between different batches was reasonably reproducible. The usefulness of radiotracers is discussed in the context of these observations

  20. Absorption and retention studies of trace elements and minerals in rats using radiotracers and whole-body counting

    NARCIS (Netherlands)

    Berg, van den G.J.; Wolterbeek, H.Th.; de Goeij, J.J.M.; Beynen, A.C.

    1995-01-01

    A description is given of a whole-body counting technique using radiotracers, permitting the determination of true absorption and endogenous excretion of trace elements and minerals in the rat in vivo. This non-invasive counting method involves oral and intraperitoneal administration of tracer doses

  1. New extraction technique for alkaloids

    Directory of Open Access Journals (Sweden)

    Djilani Abdelouaheb

    2006-01-01

    Full Text Available A method of extraction of natural products has been developed. Compared with existing methods, the new technique is rapid, more efficient and consumes less solvent. Extraction of alkaloids from natural products such as Hyoscyamus muticus, Datura stramonium and Ruta graveolens consists of the use of a sonicated solution containing a surfactant as extracting agent. The alkaloids are precipitated by Mayer reagent, dissolved in an alkaline solution, and then extracted with chloroform. This article compares the results obtained with other methods showing clearly the advantages of the new method.

  2. [{sup 11}C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Alan A., E-mail: alan.wilson@camhpet.c [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Garcia, Armando; Parkes, Jun [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Houle, Sylvain [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Tong, Junchao [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5T 1R8 (Canada); Vasdev, Neil [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada)

    2011-02-15

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([{sup 11}C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [{sup 11}C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [{sup 11}C]CURB was irreversibly bound to FAAH

  3. Delineation of heavy metal contamination pathways (seawater, food and sediment) in tropical oysters from New Caledonia using radiotracer techniques

    International Nuclear Information System (INIS)

    Hedouin, Laetitia; Metian, Marc; Teyssie, Jean-Louis; Fichez, Renaud; Warnau, Michel

    2010-01-01

    Bioaccumulation of Ag, Cd, Co, Cr and Zn was studied in the oysters Isognomon isognomon and Malleus regula, using highly sensitive radiotracer techniques. Metals were readily bioconcentrated from the dissolved phase. Sediment exposures indicated a low bioavailability of sediment-bound metals (3-5 orders of magnitude lower than dissolved metals). In both seawater and sediment experiments, the two oysters displayed similar bioaccumulation behaviour towards all metals but Ag. Indeed, Ag was much more efficiently incorporated and retained in I. isognomon. Metals ingested with food (phytoplankton) were efficiently assimilated (34-77%) and strongly retained in oyster tissues (T b1/2 ≥ 20 d). Estimation of the relative contribution of each exposure pathway indicated that for both species sediment was the dominant pathway for Co and Cd, whereas food was the major source of Zn. Regarding Ag, seawater was the main source for I. isognomon (86%), whereas sediment was the predominant route for M. regula (92%).

  4. Screening crops for efficient phosphorus acquisition in a low phosphorus soil using radiotracer technique

    International Nuclear Information System (INIS)

    Meena, S.; Malarvizhi, P.; Rajeswari, R.

    2017-01-01

    Deficiency of phosphorus (P) is the major limitation to agricultural production. Identification of cultivars with greater capacity to grow in soils having low P availability (phosphorus efficiency) will help in P management in a sustainable way. Green house experiment with maize (CO 6) and cotton (MCU 13) as test crops with four levels of phosphorus (0, 3.75, 7.50 and 15 mg P kg -1 soil) was conducted in a P deficient soil (7.2 kg ha -1 ) to study the phosphorus acquisition characteristics and to select efficient crop using 32 P radiotracer technique. Carrier free 32 P obtained as orthophosphoric acid in dilute hydrochloric acid medium from the Board of Radiation and Isotope Technology, Mumbai was used for labeling the soil @ 3200 kBq pot -1 . After 60 days the crops were harvested and the radioactivity was measured in the plant samples using Liquid scintillation counter (PerkinElmer - Tricarb 2810 TR). Different values of specific radioactivity and Isotopically Exchangeable Phosphorus for maize and cotton indicated that chemically different pools of soil P were utilized and maize accessing a larger pool than cotton. Maize having recorded high Phosphorus Use Efficiency, Phosphorus Efficiency and low Phosphorus Stress Factor values, it is a better choice for P deficient soils. Higher Phosphorus Acquisition Efficiency of maize (59 %) than cotton (48%) can be related to the ability of maize to take up P from insoluble inorganic P forms. (author)

  5. Radiotracer investigations in oil production and water injection wells

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1977-01-01

    Injection of gamma emitting radiotracers into oil wells followed by logging provides information on several aspects such as the identification of zones of seepage of water in the water injection wells and also the location of source of water entering oil producting wells. The experience gained in the application of bromine-82 and rubidium-86 as radiotracers in such studies at the Ankleshwar and Kalol oil fields in Gujarat and Nazira in Assam has been briefly reported. (author)

  6. Application of radiotracers in environmental studies

    International Nuclear Information System (INIS)

    Rathore, V.S.

    1994-01-01

    An attempt has been made to present recently emerging trends in the applicability of radiotracers in environmental studies. Since the topic is of general interest and still in the infancy, basic aspects of sampling, instrumentation and methodology are also covered

  7. Estimation of tritium radiotracer activity for interconnection study in geothermal field

    International Nuclear Information System (INIS)

    Rasi Prasetio; Satrio

    2016-01-01

    Tritium radiotracer (3H) has been applied widely in many geothermal fields around the world. This application was done by injecting radiotracer with certain amount of activity into reinjection well in order to investigate interconnection between reinjection well with surrounding production wells. The activity of injected radiotracer must meets the field condition and the volume of reservoir, detection limit of instrument, as well as safety aspect for the workers and environment from radioactive hazard. The planning of injection process must consider the maximum permissible concentration (MPC) and minimum detection limit (MDL). Based on calculation, tritium radiotracer injection in Kamojang geothermal field can be done with minimal activity of 0.15 Ci and maximum 22100 Ci, while in Lahendong field minimum activity of 0.65 Ci and maximum 7230 Ci. In these two injection studies, tritium was detected in monitoring wells between MDL and MPC limit. By using this estimation calculation, the activity of tritium that released into the environment within safety limit, thus monitoring wells with undetectable tritium infer no connectivity between those wells with reinjection well. (author)

  8. Poster — Thur Eve — 03: Application of the non-negative matrix factorization technique to [{sup 11}C]-DTBZ dynamic PET data for the early detection of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Chang [CancerCare Manitoba, Winnipeg, MB (Canada); Jans, Hans; McEwan, Sandy; Riauka, Terence [Department of Oncology, University of Alberta, Edmonton, AB (Canada); Cross Cancer Institute, Alberta Health Services, Edmonton, AB (Canada); Martin, Wayne; Wieler, Marguerite [Division of Neurology, University of Alberta, Edmonton, AB (Canada)

    2014-08-15

    In this work, a class of non-negative matrix factorization (NMF) technique known as alternating non-negative least squares, combined with the projected gradient method, is used to analyze twenty-five [{sup 11}C]-DTBZ dynamic PET/CT brain data. For each subject, a two-factor model is assumed and two factors representing the striatum (factor 1) and the non-striatum (factor 2) tissues are extracted using the proposed NMF technique and commercially available factor analysis software “Pixies”. The extracted factor 1 and 2 curves represent the binding site of the radiotracer and describe the uptake and clearance of the radiotracer by soft tissues in the brain, respectively. The proposed NMF technique uses prior information about the dynamic data to obtain sample time-activity curves representing the striatum and the non-striatum tissues. These curves are then used for “warm” starting the optimization. Factor solutions from the two methods are compared graphically and quantitatively. In healthy subjects, radiotracer uptake by factors 1 and 2 are approximately 35–40% and 60–65%, respectively. The solutions are also used to develop a factor-based metric for the detection of early, untreated Parkinson's disease. The metric stratifies healthy subjects from suspected Parkinson's patients (based on the graphical method). The analysis shows that both techniques produce comparable results with similar computational time. The “semi-automatic” approach used by the NMF technique allows clinicians to manually set a starting condition for “warm” starting the optimization in order to facilitate control and efficient interaction with the data.

  9. Radiotracer study in a bubble column reactor (visbreaker)

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Rohit Kulkarni; Pandit, A.B.; Kumar, M.M.; Berne, Ph.

    2004-01-01

    Radiotracer technique was used to measure residence time distribution (RTD) of fuel oil in a pilot-plant visbreaker with an objective to investigate hydrodynamic behaviour at different operating conditions. Bromine-82 as dibromobiphenyle was used as a tracer to measure RTD of the fuel oil. Mean residence times were determined from the measured RTD data. Tanks-in-series with backmixing model was used to simulate the measured RTD data. The results of simulation indicated that the visbreaker did not behave as a plug flow reactor as desired for visbreaking process. The presence of internals i.e. baffles inside the visbreaker decreases the mean residence time and backmixing. Thus, the designed internals have shown promising effect in terms of reduced backmixing in the visbreaker. (author)

  10. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    International Nuclear Information System (INIS)

    Wiebe, L.I.

    1984-01-01

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use. (author)

  11. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    Science.gov (United States)

    Wiebe, Leonard I.

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and (approved) medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use.

  12. Novel methodology for the study of mercury methylation and reduction in sediments and water using 197Hg radiotracer

    International Nuclear Information System (INIS)

    Ribeiro Guevara, Sergio; Perez Catan, Soledad; Zizek, Suzana; Repinc, Urska; Jacimovic, Radojko; Horvat, Milena

    2007-01-01

    Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H 2 SO 4 or HCl were evaluated in freshwater sediments using 197 Hg radiotracer. Values obtained for the 197 Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of 197 Hg 2+ into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg 2+ contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg 2+ contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H 2 SO 4 method is recommended, since it is free from these interferences. 197 Hg radiotracer (T 1/2 = 2.673 d) has a production rate that is about 50 times higher than that of 203 Hg (T 1/2 46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to 203 Hg when it is used it in short-term experiments and produced by the irradiation of 196 Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the 196 Hg isotope is increased, the specific activity of the 197 Hg tracer can be significantly improved. In the present work, 197 Hg tracer was produced from mercury 51.58% enriched in the 196 Hg

  13. Panel discussion: Chemistry aspects of pet radiotracers

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    A panel discussion on the radiotracer development process opened with a question regarding the role of toxicological studies in the process of obtaining a physician-sponsored Investigational New Drug (IND) for a new radiopharmaceutical. Panel members were uniformly supportive of new radiotracer development, expressing their opinions that the regulatory hurdles were there but could be overcome. Several institutions are actively working with regulatory agencies to determine just what toxicology data are relevant to new radiopharmaceutical development in the PET field. The FDA is beginning to understand that the pharmacology of PET tracer doses may be completely different from what is usually important in drug trials. The second part of the panel discussion centered on the role, if any, of the pharmaceutical companies in new radiotracer development. It was pointed out that what the radiochemist is looking for in a radiopharmaceutical is different from what these companies are searching for in a therapeutic drug. Panel and audience members responded to the question: What would a pharmaceutical company gain from collaboration with radiopharmaceutical research laboratories? Several examples were given such as providing crucial data from humans rather than animals; determining individualized drug doses to maximize the therapeutic index of a new drug regimen; and replacing the large amounts of time and money currently invested by drug companies in the radiolabeling and evaluation of metabolites of new drugs

  14. Vulnerability of positron emission tomography radiotracers to endogenous competition

    International Nuclear Information System (INIS)

    Laruelle, M.; Huang, Y.

    2001-01-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels

  15. Vulnerability of positron emission tomography radiotracers to endogenous competition

    Energy Technology Data Exchange (ETDEWEB)

    Laruelle, M.; Huang, Y. [Columbia University College of Physicians and Surgeons and State Psychiatric Institute, Dept. of Psychiatry and Radiology, New York, NY (United States)

    2001-06-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels.

  16. Radiotracer study of phosphate exchange between whey and casein micelles in cow's milk

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Verburg, T.G.; Dijk, H.J.M. van

    1998-01-01

    Radiotracer method has been applied to study exchange of calcium ions between the whey calcium salts and micellar calcium phosphate (MCP). The present paper deals with a similar study pertaining to phosphate ions. 32 P-labelled Na 2 HPO 4 was used as the radiotracer for inorganic phosphates of milk. After addition of the radiotracer to skimmed-milk, samples were taken regularly for 700 hours. In the samples casein micelles were separated from whey by ultracentrifugation and finally the radiotracer quantity i.e. 32 P-concentration in the whey samples was measured using a Liquid Scintillation Counter. Compartmental analysis and modelling were used to evaluate the thus obtained time curves for radiotracer quantity in whey. This analysis revealed the presence of three phosphate compartments i.e. exchangeable phosphate entities; one being the whey phosphate. The other two are associated with the exchangeable phosphates of MCP. The mean residence times of phosphate in the latter two compartment differ considerably pointing at two distinctly different embeddings of phosphate groups in the structure of the micellar calcium phosphate of the cow's milk casein. The obtained results are in fair agreement with the mentioned model of MCP

  17. Status and perspective on radiotracer technology and development of its equipment in Korea

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee; Jin, Joon Ha

    2003-01-01

    The Korean tracer team was organized under the regular research project in the middle of 1990s. The objective of the project is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems. The Korean tracer team started with basic tracer technologies and basic tools for radiotracer experiment. Under the research project, various equipments and skills for radiotracer have been developed. With these skill and equipment, there have been several demonstration experiments in petrochemical industry and waste water treatment facilities. The direction of research using radiotracer technology is highly reflected by each country's industrial situation. There is overview on how the tracer technology has applied to the industries in Korea in this paper. And the case on the application of radiotracer technology and the development of its equipment in Korea are also introduced in this paper

  18. Investigation of flow dynamics of liquid phase in a pilot-scale trickle bed reactor using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.

    2016-01-01

    A radiotracer investigation was carried out to measure residence time distribution (RTD) of liquid phase in a trickle bed reactor (TBR). The main objectives of the investigation were to investigate radial and axial mixing of the liquid phase, and evaluate performance of the liquid distributor/redistributor at different operating conditions. Mean residence times (MRTs), holdups (H) and fraction of flow flowing along different quadrants were estimated. The analysis of the measured RTD curves indicated radial non-uniform distribution of liquid phase across the beds. The overall RTD of the liquid phase, measured at the exit of the reactor was simulated using a multi-parameter axial dispersion with exchange model (ADEM), and model parameters were obtained. The results of model simulations indicated that the TBR behaved as a plug flow reactor at most of the operating conditions used in the investigation. The results of the investigation helped to improve the existing design as well as to design a full-scale industrial TBR for petroleum refining applications. - Highlights: • Residence time distributions of liquid phase were measured in a trickle bed reactor. • Bromine-82 as ammonium bromide was used as a radiotracer. • Mean residence times, holdups and radial distribution of liquid phase were quantified. • Axial dispersion with exchange model was used to simulate the measured data. • The trickle bed reactor behaved as a plug flow reactor.

  19. New-generation radiotracers for nAChR and NET

    Energy Technology Data Exchange (ETDEWEB)

    Ding Yushin [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)]. E-mail: ding@bnl.gov; Fowler, Joanna [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2005-10-01

    Advances in radiotracer chemistry and instrumentation have merged to make positron emission tomography (PET) a powerful tool in the biomedical sciences. Positron emission tomography has found increased application in the study of drugs affecting the brain and whole body, including the measurement of drug pharmacokinetics (using a positron-emitter-labeled drug) and drug pharmacodynamics (using a labeled tracer). Thus, radiotracers are major scientific tools enabling investigations of molecular phenomena, which are at the heart of understanding human disease and developing effective treatments; however, there is evidently a bottleneck in translating basic research to clinical practice. In the meantime, the poor ability to predict the in vivo behavior of chemical compounds based on their log P's and affinities emphasizes the need for more knowledge in this area. In this article, we focus on the development and translation of radiotracers for PET studies of the nicotinic acetylcholine receptor (nAChR) and the norepinephrine transporter (NET), two molecular systems that urgently need such an important tool to better understand their functional significance in the living human brain.

  20. Enviromentally Sound Timber Extracting Techniques for Small Tree Harvesting

    Science.gov (United States)

    Lihai Wang

    1999-01-01

    Due to large area disturbed and great deal of energy cost during-its operations, introducing or applying the appropriate timber extracting techniques could significantly reduce the impact of timber extraction operations to forest environment while pursuing the reasonable operation costs. Four environmentally sound timber extraction techniques for small tree harvesting...

  1. Adsorption on smooth electrodes: A radiotracer study

    International Nuclear Information System (INIS)

    Rice-Jackson, L.M.

    1990-01-01

    Adsorption on solids is a complicated process and in most cases, occurs as the early stage of other more complicated processes, i.e. chemical reactions, electrooxidation, electroreduction. The research reported here combines the electroanalytical method, cyclic voltammetry, and the use of radio-labeled isotopes, soft beta emitters, to study adsorption processes at smooth electrodes. The in-situ radiotracer method is highly anion (molecule) specific and provides information on the structure and composition of the electric double layer. The emphasis of this research was on studying adsorption processes at smooth electrodes of copper, gold, and platinum. The application of the radiotracer method to these smooth surfaces have led to direct in-situ measurements from which surface coverage was determined; anions and molecules were identified; and weak interactions of adsorbates with the surface of the electrodes were readily monitored. 179 refs

  2. Radioimmunoassay kit formulation and its validation for serum progesterone using progesterone radiotracer purified by gel filtration

    International Nuclear Information System (INIS)

    Karir, T.; Pal, N.; Sivaprasad, N.

    2003-01-01

    Purification of the radioiodinated progesterone tyrosine methyl ester conjugate by gel filtration and the development, optimization and clinical validation of a direct radioimmunoassay (RIA) of progesterone using this radiotracer are described. High purity radiotracer is essential for the error free performance of any RIA. Progesterone 11α hemisuccinate was conjugated to tyrosine methyl ester (TME) by the mixed anhydride method and this conjugate was then radioiodinated by the chloramine-T method. Purification of the radioiodinated product was carried out by gel filtration. About 12 batches of the radiotracer were prepared and purified. The purification by gel filtration gave reproducible elution pattern and purity. The radiotracer thus purified was found to have consistent quality as compared to that of any other purification methods. Non-specific binding of the radiotracer was found to be 95% as checked by paper electrophoresis. The stability (retention of the immunoreactivity) of the radiotracer was two to three months. No appreciable changes in the assay characteristics were observed during this period. The assay involved 3 hours incubation of progesterone antibody with individual standards or sample and radiotracer at room temperature. The optimized assay was then validated for internal and external quality control parameters. A RIA kit was then formulated with this radiotracer for estimation of progesterone in serum. The assay kit consisted of lyophilized individual standards ranging from 0.25 to 50 ng/ml. The clinical performance of the developed kit was compared with that of a commercial ELISA kit and a correlation of 0.94 was observed. (author)

  3. Injection and extraction techniques in circular accelerators

    International Nuclear Information System (INIS)

    Tang Jingyu

    2008-01-01

    Injection and extraction are usually the key systems in circular accelerators. They play important roles in transferring the beam from one stage acceleration to the other or to experimental stations. It is also in the injection and extraction regions where beam losses happen mostly. Due to the tight space and to reduce the perturbation to the circulating orbit, the devices are usually designed to meet special requirements such as compactness, small stray field, fast rise time or fall time, etc. Usual injection and extraction devices include septum magnets, kicker magnets, electrostatic deflectors, slow bump magnets and strippers. In spite of different accelerators and specification for the injection and extraction devices, many techniques are shared in the design and manufacturing. This paper gives a general review on the techniques employed in the major circular accelerators in China. (authors)

  4. Radiotracer investigation to study residence time distribution in an evaporator system

    Energy Technology Data Exchange (ETDEWEB)

    Pant, H J; Yelgaonkar, V N; Navada, S V [Isotope Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    Determination of mean residence time, residence time distribution and evaluation of flow behavior in industrial process systems is of prime importance in order to control the process and to evaluate the performance of the process systems. This paper describes a case study carried out in an evaporator system in a sugar factory near Pune for determination of the mean residence time and residence time distribution using radiotracer technique. The mean residence time (MRT) was determined to be 4 seconds. The mathematical modelling of residence time distribution (RTD) data indicated the flow behaviour of the system to be a well mixed type. (author). 5 refs., 2 figs., 1 tab.

  5. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    Science.gov (United States)

    Sugiharto, Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-06-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  6. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    International Nuclear Information System (INIS)

    Sugiharto; Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-01-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  7. Research of pharmacokinetics of L-threonate calcium with 45Ca radiotrace

    International Nuclear Information System (INIS)

    Tong Jian; Niu Huisheng; Li Huaifen

    2001-01-01

    The pharmacokinetics of calcium in L-threonate calcium is studied by radiotrace method. The results show the relationship between drug-time curve, pharmacokinetics parameters and dosage are positive correlation, and calcium distributes in important tissues such as stomach, intestines, blood and bone. In 24 hours, about 40% calcium is drained in urine, 30% calcium is evacuated in feces, 10%-20% calcium deposit in blood or bone. The radiotrace method is a kind of special, sensitive, accurate method of testing calcium metabolism

  8. Development of a system for real-time measurements of metabolite transport in plants using short-lived positron-emitting radiotracers

    Science.gov (United States)

    Kiser, Matthew R.

    Over the past 200 years, the Earth's atmospheric carbon dioxide (CO 2) concentration has increased by more than 35%, and climate experts predict that CO2 levels may double by the end of this century. Understanding the mechanisms of resource management in plants is fundamental for predicting how plants will respond to the increase in atmospheric CO 2. Plant productivity sustains life on Earth and is a principal component of the planet's system that regulates atmospheric CO2 concentration. As such, one of the central goals of plant science is to understand the regulatory mechanisms of plant growth in a changing environment. Short-lived positron-emitting radiotracer techniques provide time-dependent data that are critical for developing models of metabolite transport and resource distribution in plants and their microenvironments. To better understand the effects of environmental changes on resource transport and allocation in plants, we have developed a system for real-time measurements of rnetabolite transport in plants using short-lived positron-emitting radio-tracers. This thesis project includes the design, construction, and demonstration of the capabilities of this system for performing real-time measurements of metabolite transport in plants. The short-lived radiotracer system described in this dissertation takes advantage of the combined capabilities and close proximity of two research facilities at. Duke University: the Triangle Universities Nuclear Laboratory (TUNL) and the Duke University Phytotron, which are separated by approximately 100 meters. The short-lived positron-emitting radioisotopes are generated using the 10-MV tandem Van de Graaff accelerator located in the main TUNL building, which provides the capability of producing short-lived positron-emitting isotopes such as carbon-11 (11C: 20 minute half-life), nitrogen-13 (13N; 10 minute half-life), fluorine-18 (18F; 110 minute half-life), and oxygen-15 (15O; 2 minute half-life). The radioisotopes may

  9. Computer-Assisted Technique for Surgical Tooth Extraction

    Directory of Open Access Journals (Sweden)

    Hosamuddin Hamza

    2016-01-01

    Full Text Available Introduction. Surgical tooth extraction is a common procedure in dentistry. However, numerous extraction cases show a high level of difficulty in practice. This difficulty is usually related to inadequate visualization, improper instrumentation, or other factors related to the targeted tooth (e.g., ankyloses or presence of bony undercut. Methods. In this work, the author presents a new technique for surgical tooth extraction based on 3D imaging, computer planning, and a new concept of computer-assisted manufacturing. Results. The outcome of this work is a surgical guide made by 3D printing of plastics and CNC of metals (hybrid outcome. In addition, the conventional surgical cutting tools (surgical burs are modified with a number of stoppers adjusted to avoid any excessive drilling that could harm bone or other vital structures. Conclusion. The present outcome could provide a minimally invasive technique to overcome the routine complications facing dental surgeons in surgical extraction procedures.

  10. Novel methodology for the study of mercury methylation and reduction in sediments and water using {sup 197}Hg radiotracer

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro Guevara, Sergio; Perez Catan, Soledad [Centro Atomico Bariloche, Laboratorio de Analisis por Activacion Neutronica, Bariloche (Argentina); Zizek, Suzana; Repinc, Urska; Jacimovic, Radojko; Horvat, Milena [Jozef Stefan Institute, Department of Environmental Sciences, Ljubljana (Slovenia)

    2007-03-15

    Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H{sub 2}SO{sub 4} or HCl were evaluated in freshwater sediments using {sup 197}Hg radiotracer. Values obtained for the {sup 197}Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of {sup 197}Hg{sup 2+} into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg{sup 2+} contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg{sup 2+} contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H{sub 2}SO{sub 4} method is recommended, since it is free from these interferences. {sup 197}Hg radiotracer (T{sub 1/2} = 2.673 d) has a production rate that is about 50 times higher than that of {sup 203}Hg (T{sub 1/2} = 46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to {sup 203}Hg when it is used it in short-term experiments and produced by the irradiation of {sup 196}Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the {sup 196}Hg isotope is increased, the specific activity of the {sup 197}Hg tracer can be significantly improved. In

  11. Application of radiotracers in the assessment of prophylactic role of zinc in experimental model of colon carcinogenesis

    International Nuclear Information System (INIS)

    Dani, Vijayata; Vaiphei, K.; Dhawan, D.K.

    2010-01-01

    Full text: The present study elucidated the modulatory effects of zinc in 1,2 dimethylhydrazine (DMH) induced colon carcinogenesis using radiotracer techniques. Rats were segregated into four groups viz., untreated control, DMH treated, zinc treated, DMH+zinc treated. Colon carcinogenesis was induced through weekly subcutaneous injections of DMH (30 mg/Kg body weight) for 16 weeks. Zinc was supplemented to rats at a dose level of 227mg/L in drinking water, ad libitum. The prophylactic role of zinc was assessed by following radiotracer techniques viz: whole body biological half life of 65 Zn and 65 Zn biodistribution, subcellular distribution, uptake of 3 H-Thymidine to assess rate of DNA synthesis, radiorespirometric determination of 14 C-D-Glucose metabolism and in-vitro uptake of labeled aminoacids. The statistical significance of the data has been determined by using one way analysis of variance (ANOVA) followed by multiple post - hoc test. The carcinogenic state in the animals was confirmed by histopathological examination, whereby, well-differentiated signs of dysplasia were evident in colonic tissue sections of DMH treated rats. The biokinetics study of zinc revealed a significant decrease in the biological half life of 65 Zn. Also, DMH treatment caused a significant increase in the percent uptake values of 65 Zn in the colon, small intestine, kidney and blood, whereas a significant decrease was observed in the liver. The uptake rates of amino acids viz: 14 C-glycine, 14 C-alanine and 14 C-lysine were significantly higher in the DMH treated colons. Moreover, a significant increase in the uptake and turnover of 14 C-D-Glucose was also observed after DMH treatment. A significant increase in the ( 3 H)-thymidine uptake was observed following 16 weeks DMH treatment. However, supplementation of zinc significantly reversed the proliferative effect of DMH as evidenced by ameliorating the altered parameters. Radiotracer techniques play an important role in assessing

  12. Soil solution extraction techniques for microbial ecotoxicity testing: a comparative evaluation.

    Science.gov (United States)

    Tiensing, T; Preston, S; Strachan, N; Paton, G I

    2001-02-01

    The suitability of two different techniques (centrifugation and Rhizon sampler) for obtaining the interstitial pore water of soil (soil solution), integral to the ecotoxicity assessment of metal contaminated soil, were investigated by combining chemical analyses and a luminescence-based microbial biosensor. Two different techniques, centrifugation and Rhizon sampler, were used to extract the soil solution from Insch (a loamy sand) and Boyndie (a sandy loam) soils, which had been amended with different concentrations of Zn and Cd. The concentrations of dissolved organic carbon (DOC), major anions (F- , CI-, NO3, SO4(2-)) and major cations (K+, Mg2+, Ca2+) in the soil solutions varied depending on the extraction technique used. Overall, the concentrations of Zn and Cd were significantly higher in the soil solution extracted using the centrifugation technique compared with that extracted using the Rhizon sampler technique. Furthermore, the differences observed between the two extraction techniques depended on the type of soil from which the solution was being extracted. The luminescence-based biosensor Escherichia coli HB101 pUCD607 was shown to respond to the free metal concentrations in the soil solutions and showed that different toxicities were associated with each soil, depending on the technique used to extract the soil solution. This study highlights the need to characterise the type of extraction technique used to obtain the soil solution for ecotoxicity testing in order that a representative ecotoxicity assessment can be carried out.

  13. Extraction Techniques for Polycyclic Aromatic Hydrocarbons in Soils

    Science.gov (United States)

    Lau, E. V.; Gan, S.; Ng, H. K.

    2010-01-01

    This paper aims to provide a review of the analytical extraction techniques for polycyclic aromatic hydrocarbons (PAHs) in soils. The extraction technologies described here include Soxhlet extraction, ultrasonic and mechanical agitation, accelerated solvent extraction, supercritical and subcritical fluid extraction, microwave-assisted extraction, solid phase extraction and microextraction, thermal desorption and flash pyrolysis, as well as fluidised-bed extraction. The influencing factors in the extraction of PAHs from soil such as temperature, type of solvent, soil moisture, and other soil characteristics are also discussed. The paper concludes with a review of the models used to describe the kinetics of PAH desorption from soils during solvent extraction. PMID:20396670

  14. Extraction Techniques for Polycyclic Aromatic Hydrocarbons in Soils

    Directory of Open Access Journals (Sweden)

    E. V. Lau

    2010-01-01

    Full Text Available This paper aims to provide a review of the analytical extraction techniques for polycyclic aromatic hydrocarbons (PAHs in soils. The extraction technologies described here include Soxhlet extraction, ultrasonic and mechanical agitation, accelerated solvent extraction, supercritical and subcritical fluid extraction, microwave-assisted extraction, solid phase extraction and microextraction, thermal desorption and flash pyrolysis, as well as fluidised-bed extraction. The influencing factors in the extraction of PAHs from soil such as temperature, type of solvent, soil moisture, and other soil characteristics are also discussed. The paper concludes with a review of the models used to describe the kinetics of PAH desorption from soils during solvent extraction.

  15. Investigation of sorption of Hg(II) ions onto coconut husk from aqueous solution using radiotracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Hasany, S.M.; Ahmad, R.; Chaudhary, M.H. [Nuclear Chemistry Div., Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan)

    2003-07-01

    The sorption of Hg(II) ions onto coconut (Cocos nucifera) husk has been studied using radiotracer technique. Maximum sorption (96%) of Hg(II) ions (7.39 x 10{sup -6} M) onto sorbent surface is achieved from 10{sup -3} M HNO{sub 3} solution in 30 min agitation time using 100 mg of coconut husk. The sorption data follow the Freundlich and Dubinin-Radushkevich (D-R) isotherms. Sorption capacity (6.84{+-}0.45 mmol g{sup -1}) and sorption energy (10.6{+-}0.13 kJ mol{sup -1}) have been evaluated using these isotherms. Among the ions tested to monitor their influence on the sorption, Ba(II), fluoride and tartarate increased the sorption, while thiosulfate, bromide and thiocyanate reduced (< 63 > 26%) the sorption. The cations K(I), Ce(III), Cr(III), Fe(III) and Zr(IV) partially suppressed the sorption. The variation of sorption with temperature yields thermodynamic parameters {delta}H = -37.4{+-}2 kJ mol{sup -1} {delta}S = -105{+-}7 J mol{sup -1} K{sup -1} and {delta}G = -2.58{+-}0.05 kJ mol{sup -1} at 298 K. The negative values of enthalpy and free energy reflect the spontaneous and exothermic nature of sorption, respectively. The selectivity studies of sorbent show that the coconut husk column can be used to separate Hg(II) ions from Se(IV), Zn(II), I(I) and Tc (VII). The sorbent has a potential in radiochemistry to separate gamma energies of {sup 203}Hg (279 keV) from {sup 75}Se (265 and 280 keV). (orig.)

  16. Investigation of sorption of Hg(II) ions onto coconut husk from aqueous solution using radiotracer technique

    International Nuclear Information System (INIS)

    Hasany, S.M.; Ahmad, R.; Chaudhary, M.H.

    2003-01-01

    The sorption of Hg(II) ions onto coconut (Cocos nucifera) husk has been studied using radiotracer technique. Maximum sorption (96%) of Hg(II) ions (7.39 x 10 -6 M) onto sorbent surface is achieved from 10 -3 M HNO 3 solution in 30 min agitation time using 100 mg of coconut husk. The sorption data follow the Freundlich and Dubinin-Radushkevich (D-R) isotherms. Sorption capacity (6.84±0.45 mmol g -1 ) and sorption energy (10.6±0.13 kJ mol -1 ) have been evaluated using these isotherms. Among the ions tested to monitor their influence on the sorption, Ba(II), fluoride and tartarate increased the sorption, while thiosulfate, bromide and thiocyanate reduced ( 26%) the sorption. The cations K(I), Ce(III), Cr(III), Fe(III) and Zr(IV) partially suppressed the sorption. The variation of sorption with temperature yields thermodynamic parameters ΔH = -37.4±2 kJ mol -1 ΔS = -105±7 J mol -1 K -1 and ΔG = -2.58±0.05 kJ mol -1 at 298 K. The negative values of enthalpy and free energy reflect the spontaneous and exothermic nature of sorption, respectively. The selectivity studies of sorbent show that the coconut husk column can be used to separate Hg(II) ions from Se(IV), Zn(II), I(I) and Tc (VII). The sorbent has a potential in radiochemistry to separate gamma energies of 203 Hg (279 keV) from 75 Se (265 and 280 keV). (orig.)

  17. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  18. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  19. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  20. Development of equipment and radiotracer experiment using RI labelled sand in the coastal zone

    International Nuclear Information System (INIS)

    Choi, B. J.; Jung, S. H.; Kim, J. B.; Jin, J. H.

    2004-01-01

    On the basis of the radiotracer technology and the related equipments which have been developed for its industrial application through the nuclear long-term research project, a radiotracer study on sediment transport was carried out as a part of the development of the radiotracer technology for a coastal marine environment. The crystalline material doped with iridium having a similar composition and density as those of the bedload sand collected from the research area was produced by the oxide-route method. A radioisotope container was specially designed to inject the radiotracer from 1m above the sea bedload without radioactive contamination during the transport from the nuclear reactor at KAERI. The position data from the DGPS and the radiation measurement data are collected concurrently and stored by means of the application software programmed with the LabVIEW of the National Instrument. The position data is reprocessed to make it represent the real position of the radiation probe under water and not that of the DGPS antenna on board. In order to evaluate the influence of a breakwater on the deviation of the neighboring coastline, the time dependency of the spatial distribution of the sediment was studied in the area through three tracking measurements after the iridium glass was injected. This trial application showed the potential of the radiotracer technology as an important role for maintaining and developing the coastal marine environment in the future

  1. Enhancement of Twins Fetal ECG Signal Extraction Based on Hybrid Blind Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Kareem Abdullah

    2017-07-01

    Full Text Available ECG machines are noninvasive system used to measure the heartbeat signal. It’s very important to monitor the fetus ECG signals during pregnancy to check the heat activity and to detect any problem early before born, therefore the monitoring of ECG signals have clinical significance and importance. For multi-fetal pregnancy case the classical filtering algorithms are not sufficient to separate the ECG signals between mother and fetal. In this paper the mixture consists of mixing from three ECG signals, the first signal is the mother ECG (M-ECG signal, second signal the Fetal-1 ECG (F1-ECG, and third signal is the Fetal-2 ECG (F2-ECG, these signals are extracted based on modified blind source extraction (BSE techniques. The proposed work based on hybridization between two BSE techniques to ensure that the extracted signals separated well. The results demonstrate that the proposed work very efficiently to extract the useful ECG signals

  2. The role of model-based methods in the development of single scan techniques

    International Nuclear Information System (INIS)

    Laruelle, Marc

    2000-01-01

    Single scan techniques are highly desirable for clinical trials involving radiotracers because they increase logistical feasibility, improve patient compliance, and decrease the cost associated with the study. However, the information derived from single scans usually are biased by factors unrelated to the process of interest. Therefore, identification of these factors and evaluation of their impact on the proposed outcome measure is important. In this paper, the impact of confounding factors on single scan measurements is illustrated by discussing the effect of between-subject or between-condition differences in radiotracer plasma clearance on normalized activity ratios (specific to nonspecific ratios) in the tissue of interest. Computer simulation based on kinetic analyses are presented to demonstrate this effect. It is proposed that the presence of this and other confounding factors should not necessarily preclude clinical trials based on single scan techniques. First, knowledge of the distribution of plasma clearance values in a sample of the investigated population allows researchers to assign limits to this potential bias. This information can be integrated in the power analysis. Second, the impact of this problem will vary according to the characteristic of the radiotracer, and this information can be used in the development and selection of the radiotracer. Third, simple modification of the experimental design (such as administration of the radiotracer as a bolus, followed by constant infusion, rather than as a single bolus) might remove this potential confounding factor and allow appropriate quantification within the limits of a single scanning session. In conclusion, model-based kinetic characterization of radiotracer distribution and uptake is critical to the design and interpretation of clinical trials based on single scan techniques

  3. Research and development in radiotracer methodology and technology

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency (IAEA), Vienna (Austria)

    2001-07-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  4. Research and development in radiotracer methodology and technology

    International Nuclear Information System (INIS)

    Thereska, J.

    2001-01-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  5. Green chemistry using radiotracers at SINP

    International Nuclear Information System (INIS)

    Lahiri, Susanta

    2006-01-01

    Green chemistry is utilization of set of principles, which restricts the use, or generation of hazardous substances. In this aim, it is necessary to develop alternative methods, or to find greener reagents for minimum utilization of environmentally hostile substances. Radiotracers can be effectively utilized for development of such methods. This article describes the current status of Green Chemistry research using accelerator/reactor produced radionuclides at Saha Institute of Nuclear Physics, Kolkata, India. (author)

  6. Marking an antibacterial agent by Tc-99m: development of a radiotracer for the detection of infectious foci

    International Nuclear Information System (INIS)

    Ghali, Wafa

    2009-01-01

    Nuclear imaging is a non-invasive exploration technique, used for rapid diagnostic of infections disease thus, for osteoarticular infection scintigraphic techniques were proposed to ameliorate the diagnostic sensibility and the use of radiolabeled antibiotics as imaging agents of infectious loci become more ana more recognized. In this work, a new sulfanilamide derivative, The N-sulfanilamide-ferrocene-carboxamide (SFC) was chemically synthesized then labeled with technetium-99m, with a radiochemical yield, >87 pour cent. In vitro investigations were conducted, and the label's stability in serum was found as more than 20 hours at 37 degree. then uptake of labeled compound was determined by counting radioactivity in bacterial pellet of about 69 pour cent for the E.coli strain and 61,9 pour cent for S. Aureus strain, was estimated. A biodistribution study of technetium-99m - SFC allowed the comprehension of radiotracer kinetics and ways of biotransformation. And a significantly higher (p<0.05) accumulation of technetium-99m - SFC was seen at sites of S. aureus-infected animals (T/NT ratio, 2.88±0.5) compared with others radiotracers. So with all those founded results could establish that SFC may be a bacterial infection-seeking agent in staphylococcus aureus-induced infections.

  7. Investigation of hydrodynamic behaviour of a pilot-scale trickle bed reactor packed with hydrophobic and hydrophilic packings using radiotracer technique

    International Nuclear Information System (INIS)

    Rajesh Kumar; Sadhana Mohan; Pant, H.J.; Sharma, V.K.; Mahajani, S.M.

    2012-01-01

    A radiotracer study was carried out in a trickle bed reactor (TBR) independently filled with two different types of packing i.e., hydrophobic and hydrophilic. The study was aimed at to estimate liquid holdup and investigate the dispersion characteristics of liquid phase with both types of packing at different operating conditions. Water and H2 gas were used as aqueous and gas phase, respectively. The liquid and gas flow rates used ranged from 0.83 x 10 -7 -16.67 x 10 -7 m 3 /s and 0-3.33 x 10 -4 m 3 (std)/s, respectively. Residence time distribution (RTD) of liquid phase was measured using 82 Br as radiotracer and about 10 MBq activity was used in each run. Mean residence time (MRT) and holdup of liquid phase were estimated from the measured RTD data. An axial dispersion with exchange model was used to simulate the measured RTD curves and model parameters (Peclet number and MRT) were obtained. At higher liquid flow rates, the TBR behaves as a plug flow reactor, whereas at lower liquid flow rates, the flow was found to be highly dispersed. The results of investigation indicated that the dispersion of liquid phase is higher in case of hydrophobic packing, whereas holdup is higher in case of hydrophilic packing. (author)

  8. Extraction of Plutonium From Spiked INEEL Soil Samples Using the Ligand-Assisted Supercritical Fluid Extraction (LA-SFE) Technique

    International Nuclear Information System (INIS)

    Fox, R.V.; Mincher, B.J.; Holmes, R.G.G.

    1999-01-01

    In order to investigate the effectiveness of ligand-assisted supercritical fluid extraction for the removal of transuranic contaminations from soils an Idaho National Engineering and Environmental Laboratory (INEEL) silty-clay soil sample was obtained from near the Radioactive Waste Management Complex area and subjected to three different chemical preparations before being spiked with plutonium. The spiked INEEL soil samples were subjected to a sequential aqueous extraction procedure to determine radionuclide portioning in each sample. Results from those extractions demonstrate that plutonium consistently partitioned into the residual fraction across all three INEEL soil preparations whereas americium partitioned 73% into the iron/manganese fraction for soil preparation A, with the balance partitioning into the residual fraction. Plutonium and americium were extracted from the INEEL soil samples using a ligand-assisted supercritical fluid extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction efficiencies ranging from 14% to 19%. After a second round wherein the initial extraction parameters were changed, the plutonium extraction efficiencies increased to 60% and as high as 80% with the americium level in the post-extracted soil samples dropping near to the detection limits. The third round of experiments are currently underway. These results demonstrate that the ligand-assisted supercritical fluid extraction technique can effectively extract plutonium from the spiked INEEL soil preparations

  9. Deposition of heavy metals in rat hair and organs using radiotracers

    International Nuclear Information System (INIS)

    Tykva, R.; Votruba, I.; Vesely, J.; Merta, A.; Hanzlik, J.

    1993-01-01

    The basic scope of this Project consisted in the investigation of binding of individual radiometals to soluble proteins isolated form rat hair, epidermis, blood plasma, kidney and liver and in the study of putative specific transport proteins. Several types of substances, labelled with 210 Pb, 203 Hg or 109 Cd, were administered to adult Wistar A male rats kept in metabolic cages. The protein extract was subject to PAGE in the presence of SDS. It was found that lead, mercury and cadmium is tightly bound to soluble proteins from fair, plasma and tissues. The 210 Pb distribution patterns in proteins were estimated. Lead in hair has high affinity towards sulphur-rich proteins, while covalent binding of mercury via sulphhydryl groups corresponds to our analysis. The established and verified methods including investigation of binding of different elements to proteins without radiotracers represents a reliable basis for further studies. (author). 18 refs, 4 figs, 5 tabs

  10. Advanced field-solver techniques for RC extraction of integrated circuits

    CERN Document Server

    Yu, Wenjian

    2014-01-01

    Resistance and capacitance (RC) extraction is an essential step in modeling the interconnection wires and substrate coupling effect in nanometer-technology integrated circuits (IC). The field-solver techniques for RC extraction guarantee the accuracy of modeling, and are becoming increasingly important in meeting the demand for accurate modeling and simulation of VLSI designs. Advanced Field-Solver Techniques for RC Extraction of Integrated Circuits presents a systematic introduction to, and treatment of, the key field-solver methods for RC extraction of VLSI interconnects and substrate coupling in mixed-signal ICs. Various field-solver techniques are explained in detail, with real-world examples to illustrate the advantages and disadvantages of each algorithm. This book will benefit graduate students and researchers in the field of electrical and computer engineering, as well as engineers working in the IC design and design automation industries. Dr. Wenjian Yu is an Associate Professor at the Department of ...

  11. Report of the Consultants’ Meeting on the “Establishment of a training and certification system for radiotracers and NCS applications”. Proceedings of a conference

    International Nuclear Information System (INIS)

    2013-01-01

    The International Atomic Energy Agency (IAEA) has been playing a major role in facilitating the transfer of the radiotracer and sealed sources technologies to developing Member States. The major techniques have been implemented through IAEA Technical Co-operation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for education of specialists in different fields of nuclear technologies. Training course materials on the radiotracer and sealed sources methods for industrial and environmental applications have been developed for the cultivation of radiation technologies specialists and for continuing technical education of practitioners worldwide. The wide interest in radiotracer technology has created the need for highlevel professional education and training in this field, which are not necessarily covered by traditional University courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Beside this academic teaching aspect, it appears the need to create a structured training system, mainly for practitioners to ensure sustainability of the activity and to improve the recognition of the technologies and personal by the industries

  12. Methodological considerations regarding the use of inorganic 197Hg(II) radiotracer to assess mercury methylation potential rates in lake sediment

    International Nuclear Information System (INIS)

    Perez Catan, Soledad; Guevara, Sergio Ribeiro; Marvin-DiPasquale, Mark; Magnavacca, Cecilia; Cohen, Isaac Marcos; Arribere, Maria

    2007-01-01

    Methodological considerations on the determination of benthic methyl-mercury (CH 3 Hg) production potentials were investigated on lake sediment, using 197 Hg radiotracer. Three methods to arrest bacterial activity were compared: flash freezing, thermal sterilization, and γ-irradiation. Flash freezing showed similar CH 3 Hg recoveries as thermal sterilization, which was both 50% higher than the recoveries obtained with γ-ray irradiation. No additional radiolabel was recovered in kill-control samples after an additional 24 or 65 h of incubation, suggesting that all treatments were effective at arresting Hg(II)-methylating bacterial activity, and that the initial recoveries are likely due to non-methylated 197 Hg(II) carry-over in the organic extraction and/or [ 197 Hg]CH 3 Hg produced via abiotic reactions. Two CH 3 Hg extraction methods from sediment were compared: (a) direct extraction into toluene after sediment leaching with CuSO 4 and HCl and (b) the same extraction with an additional back-extraction step to thiosulphate. Similar information was obtained with both methods, but the low efficiency observed and the extra work associated with the back-extraction procedure represent significant disadvantages, even tough the direct extraction involves higher Hg(II) carry over

  13. Substoichiometric extraction of rubidium with Dibenzo-24-crown-8 into Xylene

    International Nuclear Information System (INIS)

    Bag, M.; Chattopadhyay, P.; Basu, S.

    2014-01-01

    Owing to immense applications of rubidium in varied fields, extraction and quantification of rubidium have gained great importance in recent years. Here, studies on substoichiometric extraction of rubidium by dibenzo-24-crown-8 into xylene using 86 Rb radiotracer are reported. The method has been optimized by pH of the medium, effects of diverse ions, etc, to explore its applicability in real samples

  14. Radiotracer studies of agrochemical residues in meat, milk and related products of livestock and poultry

    International Nuclear Information System (INIS)

    1987-01-01

    The joint FAO/IAEA programme was initiated in 1981 and terminates with this report. The specific objectives of the programme have been to evaluate the magnitude, fate and significance of agricultural chemical residues in edible tissues and by-products of livestock and poultry, aided by radiotracer techniques. It was anticipated that the data arising from studies conducted under this programme would be useful in assessing the toxicological significance of studied chemicals to exposed animals and to humans who may consume potentially polluted meat, milk or eggs. A separate abstract was prepared for each of the 13 papers in this report

  15. National symposium: nuclear technique in industry, medicine, agriculture and environment protection. Abstracts of papers

    International Nuclear Information System (INIS)

    1995-01-01

    The National Symposium 'Nuclear Techniques in Industry, Medicine, Agriculture and Environment Protection' has been held in Rynia near Warsaw from 24 to 27 April 1995. Totally 94 lectures have been presented. The actual state of art in Polish investigations have been shown in all branches of applied nuclear sciences. The plenary session devoted to general topics has began the symposium. Further conference has been divided into 18 subject sessions. There were: 1) radiation technologies in environment protection; 2) radiation technologies in materials engineering; 3) radiation preservation in food; 4) radiation techniques for medical use; 5) radiotracers in industrial investigations; 6) radiotracers in water and sewage management and leak control; 7) tracers in hydrology; 8) radiotracers in materials testing; 9) instruments for environment protection, 10) radiometric industrial gages; 11) diagnostic and testing instruments; 12) application of nuclear techniques in materials testing; 13) applications of nuclear techniques in geology and hydrogeology; 14) radioanalytical methods; 15) radiation detectors; 16) radiation measurements; 17) data processing from radiometric experiments; 18) accelerators, isotopes manufacturing, INIS

  16. Effect of n-octanol on the extraction behavior of trace cobalt in TOA-HCl system

    International Nuclear Information System (INIS)

    Mukhopadhyay, Krishnendu; Mandal, Anjana; Mukhopadhyay, Banani; Nayak, Dalia; Lahiri, Susanta

    1997-01-01

    Effect of the presence of n-octanol in the extraction of traces of cobalt in HCl-TOA system was studied. In the extraction, both synergistic and antagonistic effects, depending on the volume of alcohol present, were observed. Extraction behaviour of the element was studied radiometrically using 57,58 Co, produced by α- particle bombardment of cobalt, as radiotracer for the element. (author). 1 fig

  17. Extraction of kiwi seed oil: Soxhlet versus four different non-conventional techniques.

    Science.gov (United States)

    Cravotto, Giancarlo; Bicchi, Carlo; Mantegna, Stefano; Binello, Arianna; Tomao, Valerie; Chemat, Farid

    2011-06-01

    Kiwi seed oil has a nutritionally interesting fatty acid profile, but a rather low oxidative stability, which requires careful extraction procedures and adequate packaging and storage. For these reasons and with the aim to achieve process intensification with shorter extraction time, lower energy consumption and higher yields, four different non-conventional techniques were experimented. Kiwi seeds were extracted in hexane using classic Soxhlet as well as under power ultrasound (US), microwaves (MWs; closed vessel) and MW-integrated Soxhlet. Supercritical CO₂ was also employed and compared to the other techniques in term of yield, extraction time, fatty acid profiles and organoleptic properties. All these non-conventional techniques are fast, effective and safe. A sensory evaluation test showed the presence of off-flavours in oil samples extracted by Soxhlet and US, an indicator of partial degradation.

  18. High intensity pulsed electric field as an innovative technique for extraction of bioactive compounds-A review.

    Science.gov (United States)

    Yan, Liang-Gong; He, Lang; Xi, Jun

    2017-09-02

    How to extract bioactive compounds safely and efficiently is one of the problems for the food and pharmaceutical industry. In recent years, several novel extraction techniques have been proposed. To pursue a more efficient method for industrial production, high intensity pulsed electric field (HIPEF) extraction technique has been developed. HIPEF extraction technique, which is based on the conventional pulsed electric field (PEF), provided higher electric field intensity and a special continuous extraction system, and it has confirmed less extraction time, higher extraction yield, and mild processing temperature. So this innovative technique is promising for application of industrial production. This review was devoted to introducing the recent achievement of HIPEF extraction technique, including novel HIPEF continuous extraction system, principles and mechanisms; the critical process factors influencing its performance applications; and comparison of HIPEF extraction with other extraction techniques. In the end, the defects and future trends of HIPEF extraction were also discussed.

  19. Comparative screening of the anti-oxidant and antimicrobial activities of Sempervivum marmoreum L. extracts obtained by various extraction techniques

    Directory of Open Access Journals (Sweden)

    SASA S. STOJICEVIC

    2008-06-01

    Full Text Available This paper presents a comparative study of the anti-oxidant and anti-microbial activities, total phenolic compounds and total flavonoids in extracts obtained from houseleek (Sempervivum marmoreum L. leaves by the classical (maceration, ultrasonic and Soxhlet extraction (CE, UE and SE, respectively. The extract obtained by the CE contained higher amounts of phenolic and flavonoid compounds and showed a better antioxidant activity than those obtained using other two techniques. All the extracts, independent of the extraction technique applied, showed antimicrobial activities against Aspergillus niger and Candida albicans only but not against the tested bacteria.

  20. Application of Nuclear Techniques in Industry and the Environment

    International Nuclear Information System (INIS)

    Masinza, A.S.

    2015-01-01

    Major radiotracer techniques are now in routine service industry to optimize processes, solve problems improve product quality, save energy and reduction pollution. The benefit to cost ratios of radiotracers, sealed sources and nucleonic gauges applications are considerably high; between 10:1 and 4000:1. The number of services for troubleshooting carried out worldwide per year is in excess of tens of thousands (out of them greater than 5000 are gamma scans). The number of nucleonic gauges worldwide could be estimated to be greater that 250,000 (Author)

  1. Industrial applications of nuclear techniques in Poland

    International Nuclear Information System (INIS)

    Michalik, J.St.

    1981-01-01

    Application of radioisotope techniques in a number of Polish industries was reviewed. Studies on the usage of radiotracer as an evaluation method for technological processes were carried out and the advantages of such application were discussed

  2. Challenges in the development of dopamine D2- and D3-selective radiotracers for PET imaging studies.

    Science.gov (United States)

    Mach, Robert H; Luedtke, Robert R

    2018-03-01

    The dopamine D2-like receptors (ie, D2/3 receptors) have been the most extensively studied CNS receptor with Positron Emission Tomography (PET). The 3 different radiotracers that have been used in these studies are [ 11 C]raclopride, [ 18 F]fallypride, and [ 11 C]PHNO. Because these radiotracers have a high affinity for both dopamine D2 and D3 receptors, the density of dopamine receptors in the CNS is reported as the D2/3 binding potential, which reflects a measure of the density of both receptor subtypes. Although the development of D2- and D3-selective PET radiotracers has been an active area of research for many years, this by and large presents an unmet need in the area of translational PET imaging studies. This article discusses some of the challenges that have inhibited progress in this area of research and the current status of the development of subtype selective radiotracers for imaging D3 and D2 dopamine receptors with PET. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Application of 99mTc-DTPA Radiotracer in Persian Cat's Renal ...

    African Journals Online (AJOL)

    Keywords: Kidney, Persian cat, Radiotracer, Scintigraphy, Technetium-99m diethylene triamine pentacaetic acid ... tracer can be detected in the body by medical equipment .... studies, such as kidney failure, allergic reactions and fatal side ...

  4. A radiotracer technique for the migration of inorganic contaminants into dry food from packaging made from recycled paper and board

    International Nuclear Information System (INIS)

    Aston, D.S.J.; Parry, S.J.

    2005-01-01

    A radiotracer method, initially developed to analyze migration from retail plastic food packaging into food simulants, has been developed to assess the measurement of inorganic contaminants migrating from recycled paper and board into real food. This new radiotracer method has been applied to the study of 10 food samples and their corresponding recycled paper and board packaging. Samples of paper and board were irradiated in a thermal neutron flux of 1.26 x 10 16 n x m -2 x s -1 for 15 hours to activate elements of interest. After a decay period of 10 days the paper and board was placed in contact with the corresponding foodstuff. The food was analyzed for any radioactivity migrating from the packaging by gamma-ray spectrometry. Samples were analyzed regularly during the 90 days contact time. Detection limits for the determination of migration was as low as a few μg/kg in the food. Results from the migration study have shown that, of the 60 elements measured, only Zn and Fe were detected in food, at concentrations of 0.012-0.25, and 0.045-0.11 mg/kg, respectively. This was despite the recycled paper and board samples being highly elevated in many other elements such as Cr (0.9-15.1 mg/kg) and Ba (3.3-75.4 mg/kg). The level of migration of Zn and Fe into food from packaging was insignificant compared to the UK recommended daily allowances of 15 mg, and, therefore, represented no hazard to human health. (author)

  5. Distributed microprocessor automation network for synthesizing radiotracers used in positron emission tomography

    International Nuclear Information System (INIS)

    Russell, J.A.G.; Alexoff, D.L.; Wolf, A.P.

    1984-01-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. 20 refs. (DT)

  6. Synthesis and marking with technetium and rhenium of a new radiotracer from para-toluidine

    International Nuclear Information System (INIS)

    Laouini, Emna

    2011-01-01

    The development of nuclear medicine is based on the research of new radiotracers especially those which target the neuro degenerative diseases. In fact, the precocious diagnostic of these diseases using the radiopharmaceuticals is the only mean to defeat it. The biodistribution of a new cytectrene derivative from para-toluidine, having a lipophilic character and a low molecular weight, showed a new radiotracer which is able to clear the blood brain barrier and characterised with prolonged brain retention. The features of this complex contribute to make it a radiopharmaceutical to diagnostic aim in clinical use.

  7. Mitigation of the voltage fluctuations using an efficient disturbance extraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Elnady, Amr; Salama, M.M.A. [University of Waterloo, Electrical and Computer Engineering, 200 University Ave. West, Waterloo, Ont. (Canada N2L3G1)

    2007-03-15

    This paper introduces an efficient technique for extracting the disturbance signal of the voltage flicker. The proposed technique depends on the supervised state estimation that is controlled by the Widrow-Hoff delta rule. The extracted disturbance signal is employed for mitigating the cyclic voltage flicker by using series and parallel mitigating devices. The speed and accuracy of the proposed technique are verified by simulation results with EMTDC/PSCAD. In addition, experimental results are presented to prove the validity of the proposed algorithm. (author)

  8. Synthesis of a new technetium brain radiotracer

    International Nuclear Information System (INIS)

    El Aissi, Radhia

    2009-01-01

    The radiological diagnosis of brain diseases, including neurodegenerative ones, is still difficult because of the absence of specific biological markers. These diseases are then increasingly the subject of researches and new experiments. The biodistribution of a new cytectrenes-aniline derivative, having a lipophilic character and low molecular weight, showed a prolonged brain retention and a specific tissue distribution of the hippocampus. This radiotracer could contribute to establish early diagnosis of neurodegenerative diseases thanks to its affinity with a serotonin receptors-rich region. (Author)

  9. Increased bone radiotracer uptake in renal osteodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    de Graaf, P.; Schicht, I.M.; de Graeff, J.; te Velde, J.; Kleiverda, K.; Pauwels, E.K.J.

    1982-04-01

    Bone radiotracer uptake in renal osteodystrophy was investigated in 35 dialysis patients by correlating the results of quantitative bone scintigraphy with those of biochemical and bone morphometric studies. There were highly significant correlations (P < 0.001) between the total skeletal activity and the biochemical (iPTH and alkaline phosphatase), and histologic parameters of hyperparathyroidism. These clinical results strongly suggest that increased bone turnover i.e. hyperparathyroidism, rather than osteomalacia is the major cause of increased skeletal uptake in renal osteodystrophy.

  10. Solvent extraction of Sb(III) with malachite green into chloroform

    International Nuclear Information System (INIS)

    Shanbhag, B.S.; Turel, Z.R.

    2002-01-01

    A rapid and selective method for the solvent extraction of Sb(III) using malachite green (C. I. Basic green 4) has been described. Effect of different parameters affecting the extraction coefficient value of Sb(III) such as acidity, time of equilibration, KI concentration, solvents, anions, etc. has been studied. For various elements the separation factor has been evaluated. The stoichiometry of the extracted species has been determined by the method of substoichiometric extraction. The decontamination factor for some elements using substoichiometric quantities of the extracting agent has been evaluated. Radiotracers were employed for the extraction studies. The method elaborated has been employed for the quantitative determination of antimony in normal, benign and cancerous tissues of the human brain. (author)

  11. [Platelet rich plasma (PRP): potentialities and techniques of extraction].

    Science.gov (United States)

    Pacifici, L; Casella, F; Maggiore, C

    2002-01-01

    This paper describes the various techniques of platelet-rich plasma (PRP) extraction codified in recent years and their use potential is evaluated. PRP is one of the techniques with which at the moment it is attempted to modulate and facilitate the cure of a wound. The use of PRP is based on the theoretical premise that by concentrating platelets the effects of the growth factors (PDGF, TGF-beta, IGF-I and -II) so released will be increased. Marx's original technique is described above all. This prescribes the sampling of a unit of blood (450-500 ml) and the use of a cell separator. We then analysed the technique of Marx and Hannon in which the quantity of blood sampled is reduced to 150 ml, and the two simplified techniques of the Sacchi and Bellanda group. Finally, a new PRP extraction technique is described. We conclude that platelet gel allows access to autologous growth factors which by definition are neither toxic nor immunogenic and are capable of accelerating the normal processes of bone regeneration. PRP can thus be considered a useful instrument for increasing the quality and final quantity of regenerated bone in oral and maxillo-facial surgery operations.

  12. Comparaison de quelques techniques d'extraction pour l ...

    African Journals Online (AJOL)

    Objectif: La présente étude vise à améliorer la technique d'extraction du jus de la pomme cajou au Bénin. Cette technique peu efficiente consiste à presser les pommes de cajou fraiches à l'aide d'une presse à vis simple mais une quantité non négligeable de liquide reste emprisonnée dans la matrice. Méthodologie et ...

  13. [18F]Fallypride: Metabolism studies and quantification of the radiotracer and its radiometabolites in plasma using a simple and rapid solid-phase extraction method

    International Nuclear Information System (INIS)

    Peyronneau, Marie-Anne; Saba, Wadad; Goutal, Sébastien; Kuhnast, Bertrand; Dollé, Frédéric; Bottlaender, Michel; Valette, Héric

    2013-01-01

    Introduction: [ 18 F]Fallypride, a fluorinated and substituted benzamide with high affinity for D 2 /D 3 receptors, is a useful PET radioligand for the study of striatal/extrastriatal areas. Since [ 18 F]fallypride is extensively metabolized in vivo and since PET examinations are long lasting in humans, the rapid measurement of the unchanged radiotracer in plasma is essential for the quantification of images. The present study aims: i) to evaluate if the radiometabolites of [ 18 F]fallypride cross the blood–brain barrier in rodents, ii) to identify these radiometabolites in baboon plasma and iii) to develop a rapid solid phase extraction method (SPE) suitable for human applications to quantify both [ 18 F]fallypride and its radiometabolites in plasma. Methods: The metabolites P450-dependant in rat and human liver microsomes were characterized by LC–MS–MS and compared to those detected in vivo. Sequential solvent elution on Oasis®-MCX-SPE cartridges was used to quantify [ 18 F]fallypride and its radiometabolites. Result: In rat microsomal incubations, five metabolites generated upon N/O-dealkylation or hydroxylation at the pyrrolidine and/or at the benzamide moiety were identified. No radiometabolite was detected in the rat brain. N-dealkylated and hydroxylated derivatives were detected in human microsomal incubations as well as in baboon plasma. The use of SPE (total recovery 100.2% ± 2.8%, extraction yield 95.5% ± 0.3%) allowed a complete separation of [ 18 F]fallypride from its radiometabolites in plasma and evaluate [ 18 F]fallypride at 150 min pi to be 22% ± 5% of plasma radioactivity. Conclusions: The major in vivo radiometabolites of [ 18 F]fallypride were produced by N-dealkylation and hydroxylation. Allowing the rapid analysis of multiple plasma samples, SPE is a method of choice for the determination of [ 18 F]fallypride until late images required for quantitative PET imaging in humans

  14. Radiotracer investigation in gold leaching tanks

    International Nuclear Information System (INIS)

    Dagadu, C.P.K.; Akaho, E.H.K.; Danso, K.A.; Stegowski, Z.; Furman, L.

    2012-01-01

    Measurement and analysis of residence time distribution (RTD) is a classical method to investigate performance of chemical reactors. In the present investigation, the radioactive tracer technique was used to measure the RTD of aqueous phase in a series of gold leaching tanks at the Damang gold processing plant in Ghana. The objective of the investigation was to measure the effective volume of each tank and validate the design data after recent process intensification or revamping of the plant. I-131 was used as a radioactive tracer and was instantaneously injected into the feed stream of the first tank and monitored at the outlet of different tanks. Both sampling and online measurement methods were used to monitor the tracer concentration. The results of measurements indicated that both the methods provided identical RTD curves. The mean residence time (MRT) and effective volume of each tank was estimated. The tanks-in-series model with exchange between active and stagnant volume was used and found suitable to describe the flow structure of aqueous phase in the tanks. The estimated effective volume of the tanks and high degree of mixing in tanks could validate the design data and confirmed the expectation of the plant engineer after intensification of the process. - Highlights: ► I-131 radioactive tracer is suitable for tracing the aqueous phase in gold ore slurry. ► Online data collection is more convenient method for tracer monitoring in industrial process systems. ► The tanks-in-series model with exchange between active and stagnant zones is suitable to describe the flow behavior of leaching tanks. ► The radiotracer RTD technique could be used to validate design data after process intensification in gold leaching tanks.

  15. Radiotracer investigation in gold leaching tanks

    Energy Technology Data Exchange (ETDEWEB)

    Dagadu, C.P.K., E-mail: dagadukofi@yahoo.co.uk [Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Akaho, E.H.K.; Danso, K.A. [Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Stegowski, Z.; Furman, L. [Faculty of Physics and Applied Computer Science, AGH-UST, 30-059 Krakow (Poland)

    2012-01-15

    Measurement and analysis of residence time distribution (RTD) is a classical method to investigate performance of chemical reactors. In the present investigation, the radioactive tracer technique was used to measure the RTD of aqueous phase in a series of gold leaching tanks at the Damang gold processing plant in Ghana. The objective of the investigation was to measure the effective volume of each tank and validate the design data after recent process intensification or revamping of the plant. I-131 was used as a radioactive tracer and was instantaneously injected into the feed stream of the first tank and monitored at the outlet of different tanks. Both sampling and online measurement methods were used to monitor the tracer concentration. The results of measurements indicated that both the methods provided identical RTD curves. The mean residence time (MRT) and effective volume of each tank was estimated. The tanks-in-series model with exchange between active and stagnant volume was used and found suitable to describe the flow structure of aqueous phase in the tanks. The estimated effective volume of the tanks and high degree of mixing in tanks could validate the design data and confirmed the expectation of the plant engineer after intensification of the process. - Highlights: Black-Right-Pointing-Pointer I-131 radioactive tracer is suitable for tracing the aqueous phase in gold ore slurry. Black-Right-Pointing-Pointer Online data collection is more convenient method for tracer monitoring in industrial process systems. Black-Right-Pointing-Pointer The tanks-in-series model with exchange between active and stagnant zones is suitable to describe the flow behavior of leaching tanks. Black-Right-Pointing-Pointer The radiotracer RTD technique could be used to validate design data after process intensification in gold leaching tanks.

  16. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    Science.gov (United States)

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  17. Radiotracers in Swedish Steel Industry

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, I.; Erwall, L. G. [Isotope Techniques Laboratory, Stockholm (Sweden); Nyquist, O. [Surahammars Bruks AB, Surahammar (Sweden)

    1967-06-15

    Recent tracer investigations in Swedish steel plants have mainly dealt with problems concerning uon-metallic inclusions, slag weight determination and - labelling of special steel qualities for identification. Suspected inclusion sources, such as furnace slag, ladle-bottom mortar and some brick materials as stopper, nozzle.and channel bricks have been labelled radioactively in different ways. The labelling technique has been studied for the different systems and a new method was developed for brick materials. This includes vacuum impregnation with an aqueous solution of the inactive tracer, reheating to 1300 Degree-Sign C and neutron-irradiation in a reactor. A sufficiently homogeneous labelling of the material was obtained in this way. The tracer used was terbium, which was added as the nitrate and then decomposed to oxide during the heating process. The oxide is strongly bound to the ceramic material. The number of radioactive inclusions was determined by.autoradiography, and related to the total number pf inclusions, obtained by visual slag-counting, to give the percentage of inclusions originating from the labelled object. Some investigations have been made using simultaneous labelling of two or more sources. It seems to be difficult, however, to measure separately more than two tracers: one short-lived (e.g. 140La) and one long-lived (e.g. {sup 160}Tb). The slag weight determinations were made using the isotope dilution technique with {sup 131}Ba and {sup 140}La as tracers. A difference in slag weight is sometimes obtained. An attempt is made to explain these deviations. The material transport through a blast furnace has been followed by using a piece of graphite, labelled with {sup 140}La{sub 2}O{sub 3}, and measuring the radiation intensity outside the furnace walls and in the tuyere. Studies have been made to determine suitable radiotracers for labelling of steel for subsequent identification. Up to three different isotopes can be used simultaneously

  18. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, J.; Flores Juan, P.; Cuesta Borges, J.; Damera Martinez, A.; Ramos Espinosa, K. A

    2005-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one with Low Residence Time (BTR), both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented. Several trials performed at the two Clarifiers demonstrated that the one identified as BTR was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The radiotracer method was able to detect certain differences between the two clear juice outlet of the BTR Clarifier, probably due some problems in the construction of this equipment

  19. Radiotracer technology as applied to industry. Final report of a co-ordinated research project 1997-2000

    International Nuclear Information System (INIS)

    2001-12-01

    The Co-ordinated Research Project (CRP) on Radiotracer Technology for Engineering Unit Operation Studies and Unit Process Optimization was carried out by the International Atomic Energy Agency (IAEA) from December 1997 until December 2000. The project developed and validated procedures and protocols for investigation of major industrial processes, including fluidized beds, sugar crystallizers, trickle bed reactors, cement rotary kilns, flotation cells, grinding mills, incinerators, wastewater treatment units and interwell communications in oil fields. This publication is the output of the above mentioned CRP. It provides the principles and state of the art of radiotracer methodology and technology as applied to industry and environment. It is expected to provide wider interest for further development of skills and confidence prior to carrying out field work. It facilitates transfer of technology from developed to developing countries and from nuclear research institutions to industrial end users. The publication could be a suitable guide for radiotracer applications in almost all types of process investigations. The case studies described in this publication deal with typical problems in industry and environment common to all countries. It is intended for radiotracer groups as well as for end engineers and managers from chemical and petrochemical industries, mineral ore and raw material processing, wastewater treatment plants, and other industrial sectors

  20. Estimation of shell thickness in a continuously cast steel billet using radiotracers

    International Nuclear Information System (INIS)

    Prasad, A.S.; Pandey, J.C.; Kaur, G.

    1994-01-01

    In the continuous casting of steel, one of the factors which limits the rate of faster withdrawal of the casting from the mould is the thickness of the solid shell below the mould. If the shell can not contain the liquid pool, breakouts occur and process of casting disrupts. Estimates of shell thickness have been made on the basis of heat- transfer considerations. The shell thickness could also be delineated, to some extent, by adding radiotracers during casting and subsequently determining the dispersion of radioactivity by autoradiography. The paper presents the results of the estimation of shell thickness based on the heat-transfer model and validation of the model by plant trials using radiotracers. (author). 11 refs., 5 figs., 1 tab

  1. Radiotracer diffusion in semiconductors and metallic compounds using short-lived isotopes

    CERN Multimedia

    Deicher, M; Kronenberg, J; Wagner, F E

    The transport of atoms in solids is of central importance for solid state physics, chemistry, metallurgy, and material sciences. Since the mobility of atoms in solids contributes to many physical phenomena the study of diffusion processes is of fundamental interest for solid state physics. Diffusion processes were frequently investigated using radioactive isotopes (radiotracers). The application of short-lived isotopes delivered at ISOLDE extends substantially the possibilities of investigating diffusion processes in solids. In particular, a new experimental set-up to be installed at ISOLDE in this year will enable the use of radioactive isotopes with half-lives down to minutes. Alternatively, in special cases diffusion processes can be investigated with help of hyperfine techniques on an atomic scale, like by perturbed $\\gamma \\gamma$-angular correlation (PAC). Here, the motion of the atom of interest becomes visible directly via characteristic changes in the measured PAC spectra.

  2. Radiotracers for PETT: new developments and perspectives

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references

  3. Indepth diagnosis of a secondary clarifier by the application of radiotracer technique and numerical modeling.

    Science.gov (United States)

    Kim, H S; Shin, M S; Jang, D S; Jung, S H

    2006-01-01

    To make an indepth diagnosis of a full-scale rectangular secondary clarifier, an experimental and numerical study has been performed in a wastewater treatment facility. Calculation results by the numerical model with the adoption of the SIMPLE algorithm of Patankar are validated with radiotracer experiments. Emphasis is given to the prediction of residence time distribution (RTD) curves. The predicted RTD profiles are in good agreement with the experimental RTD curves at the upstream and center sections except for the withdrawal zone of the complex effluent weir structure. The simulation results predict successfully the well-known flow characteristics of each stage such as the waterfall phenomenon at the front of the clarifier, the bottom density current and the surface return flow in the settling zone, and the upward flow in the exit zone. The detailed effects of density current are thoroughly investigated in terms of high SS loading and temperature difference between influent and ambient fluid. The program developed in this study shows the high potential to assist in the design and determination of optimal operating conditions to improve effluent quality in a full-scale secondary clarifier.

  4. Radiotracer design strategies for neurocardiology

    International Nuclear Information System (INIS)

    Wieland, D.M.; Hutchins, G.D.

    1991-01-01

    Nuclear cardiologists have expended an inordinate amount of effort studying the open-quotes plumbingclose quotes of the heart but very little effort on the open-quotes wiringclose quotes. L. Rossi declared in 1988, open-quotes today's desultory information about basic changes in the heart's innervation, if compared with current knowledge about diseases of cardiac muscle and vessels, is largely attributable to an aura of forbidding technical difficulty.close-quote During the past three years, radiotracers have been developed for use in studies of cardiac nerve function by positron emission tomography (PET). The first clinical PET studies in this area were reported in 1990. This chapter discusses the strategies that led to the tracers presently available and the possible nature of future neuronal markers

  5. Methodological considerations regarding the use of inorganic {sup 197}Hg(II) radiotracer to assess mercury methylation potential rates in lake sediment

    Energy Technology Data Exchange (ETDEWEB)

    Perez Catan, Soledad [Laboratorio de Analisis por Activacion Neutronica, Comision Nacional de Energia Atomica, Centro Atomico Bariloche, 8400 Bariloche (Argentina); Guevara, Sergio Ribeiro [Laboratorio de Analisis por Activacion Neutronica, Comision Nacional de Energia Atomica, Centro Atomico Bariloche, 8400 Bariloche (Argentina)], E-mail: ribeiro@cab.cnea.gov.ar; Marvin-DiPasquale, Mark [US Geological Survey, 345 Middlefield Rd./MS 480, Menlo Park, CA 94025 (United States); Magnavacca, Cecilia [Centro Atomico Ezeiza, Comision Nacional de Energia Atomica, Presbitero Gonzalez y Aragon No. 15, B1802AYA, Ezeiza, Buenos Aires (Argentina); Cohen, Isaac Marcos [Departamento de Ingenieria Quimica, Facultad Regional Buenos Aires, Universidad Tecnologica Nacional, Medrano 951 (C1179AAQ) Buenos Aires (Argentina); Arribere, Maria [Laboratorio de Analisis por Activacion Neutronica, Comision Nacional de Energia Atomica, Centro Atomico Bariloche, 8400 Bariloche (Argentina)

    2007-09-15

    Methodological considerations on the determination of benthic methyl-mercury (CH{sub 3}Hg) production potentials were investigated on lake sediment, using {sup 197}Hg radiotracer. Three methods to arrest bacterial activity were compared: flash freezing, thermal sterilization, and {gamma}-irradiation. Flash freezing showed similar CH{sub 3}Hg recoveries as thermal sterilization, which was both 50% higher than the recoveries obtained with {gamma}-ray irradiation. No additional radiolabel was recovered in kill-control samples after an additional 24 or 65 h of incubation, suggesting that all treatments were effective at arresting Hg(II)-methylating bacterial activity, and that the initial recoveries are likely due to non-methylated {sup 197}Hg(II) carry-over in the organic extraction and/or [{sup 197}Hg]CH{sub 3}Hg produced via abiotic reactions. Two CH{sub 3}Hg extraction methods from sediment were compared: (a) direct extraction into toluene after sediment leaching with CuSO{sub 4} and HCl and (b) the same extraction with an additional back-extraction step to thiosulphate. Similar information was obtained with both methods, but the low efficiency observed and the extra work associated with the back-extraction procedure represent significant disadvantages, even tough the direct extraction involves higher Hg(II) carry over.

  6. The Best Extraction Technique for Kaempferol and Quercetin Isolation from Guava Leaves (Psidium guajava)

    Science.gov (United States)

    Batubara, I.; Suparto, I. H.; Wulandari, N. S.

    2017-03-01

    Guava leaves contain various compounds that have biological activity such as kaempferol and quercetin as anticancer. Twelve extraction techniques were performed to obtain the best extraction technique to isolate kaempferol and quercetin from the guava leaves. Toxicity of extracts was tested against Artemia salina larvae. All extracts were toxic (LC50 value less than 1000 ppm) except extract of direct soxhletation on guava leaves, and extract of sonication and soxhletation using n-hexane. The extract with high content of total phenols and total flavonoids, low content of tannins, intense color of spot on thin layer chromatogram was selected for high performance liquid chromatography analysis. Direct sonication of guava leaves was chosen as the best extraction technique with kampferol and quercetin content of 0.02% and 2.15%, respectively. In addition to high content of kaempferol and quercetin, direct sonication was chosen due to the shortest extraction time, lesser impurities and high toxicity.

  7. An alternative gallbladder extraction technique in laparoscopic cholecystectomy.

    Science.gov (United States)

    Tang, C N; Wong, D C T

    2006-05-01

    In this era of minimally invasive surgery, the challenge remains in finding techniques to reduce access trauma in terms of fewer and smaller size trocar ports. Our new described technique will allow a smaller subxiphoid port to be used to achieve extraction of the gallbladder without the need to change to a 5 mm laparoscope. We believe this method is easy to learn, safe and with no observable complications from our experience.

  8. Study of technological parameters influence on homogeneity of rubber mixings by means of radiotracer methods

    International Nuclear Information System (INIS)

    Koczorowska, E.

    1995-01-01

    The radiotracer methods have been worked out for analysis of physico-chemical phenomena. The analysis were carried out for rubber mixings in technological conditions and played a deciding role for quality of manufacturing assortment. The 35 S and 65 Zn have been used as radiotracers. Analysis of different technological parameters influence on behaviour of soluble and polymerized sulfur, zinc compounds as well as other components of the rubber mixing enables to formulate the conclusions important for rubber industry and technology from view point of quality of manufacturing products

  9. The early use of radiotracers in chemistry

    International Nuclear Information System (INIS)

    Grabowski, K.F.M.

    1986-01-01

    This article describes the historical background to the use of radiotracers, pioneered by de Hevesy and Paneth before World War I. It traces their early use in ion and metal interchange in electrolysis, self-diffusion rates, early biochemical experiments on lead uptake in plants, phosphorus metabolism in rats, through to their wider use with the production of artificial radioisotopes after World War II. Photosynthesis experiments using carbon-11 and carbon-14 are described and their present-day widespread use in kinetics, metabolic pathway studies and therapeutics is discussed. (UK)

  10. Radiotracers for PETT: new developments and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references. (PSB)

  11. Comparison of clearance and arteriovenous extraction techniques for measurements of renal hemodynamic functions

    International Nuclear Information System (INIS)

    Katzberg, R.W.; Pabico, R.C.; Morris, T.W.; Hayakawa, K.; McKenna, B.A.; Ventura, J.A.; Fischer, H.W.

    1986-01-01

    No previous studies have directly compared timed urine collections (UV/P) vs. arteriovenous (A-V) extraction methods for determination of renal function in whole kidney preparations. We examined different markers and techniques for assessing renal plasma flow (RPF), filtration fraction (FF), and glomerular filtration rate (GFR) in both steady-state and rapidly changing conditions following 2 ml/kg bolus intravenous injections of either Renografin 76% (meglumine/sodium diatrizoate-76%) or hypertonic mannitol 25%. During steady-state conditions, excellent correlations were obtained when comparing markers and techniques. Thus, timed urinary clearances of inulin vs. 99m-technetium DTPA (Tc) had a correlation coefficient (R) of .96 (P less than .01; n = 16), and the A-V extraction technique of inulin vs. Tc as determinants of GFR showed a correlation of R = .98 (P less than .01; n = 15). The timed urinary clearance of inulin vs. the A-V extraction of inulin for glomerular filtration gave a correlation of R = .93 (P less than .01; n = 15). The clearance of para-aminohippurate (PAH) divided by the extraction of PAH vs. flow determinations using the electromagnetic flowmeter gave a correlation of R = .92 (P less than .01; n = 16). The anticipated decrease in GFR following contrast medium and hypertonic mannitol was observed using the A-V extraction technique, whereas an artifactual, exaggerated increase in GFR was observed using the timed urine collection technique. Similarly, we noted an exaggerated increase in RPF using CPAH/EPAH as the methodology. We conclude that rapid changes in renal hemodynamics may be measured accurately using the A-V extraction technique but not with clearance techniques requiring timed urine collections

  12. Application of analogue computers to radiotracer data processing

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1979-01-01

    Some applications of analogue computers for processing the flow-system radiotracer-investigation data are presented. Analysis of the impulse response shaped to obtain the frequency response of the system under consideration can be performed on the basis of an estimated transfer function. Furthermore, simulation of the system behaviour for other excitation functions is discussed. Simple approach is made for estimating the model parameters in situations where the input signal is not approximated by the unit impulse function. (author)

  13. Preparation of the Nanostructured Radioisotope Metallic Oxide by Neutron Irradiation for Use as Radiotracers

    Directory of Open Access Journals (Sweden)

    Sang-Ei Seo

    2017-10-01

    Full Text Available Metallic oxides manganese dioxide (MnO2, samarium oxide (Sm2O3, and dysprosium oxide (Dy2O3 with nanorod-like structures were synthesized by the hydrothermal synthesis method, respectively. Subsequently, the nanostructured radioisotopes MnO2 with Mn-56, Sm2O3 with Sm-153, and Dy2O3 with Dy-165 were prepared by neutron irradiation from the HANARO research reactor, respectively. The three different elements, Mn, Sm, and Dy, were selected as radiotracers because these elements can be easily gamma-activated from neutrons (activation limits: 1 picogram (Dy, 1–10 picogram (Mn, 10–100 picogram (Sm. Furthermore, the synthesized radioisotopes can be used as radiotracers in Prompt Gamma Neutron Activation Analysis as the rare earth metals Dy and Sm were not present in the Korean environment. The successful synthesis of the radioisotope metallic oxides was confirmed by Transmission Electron Microscopy (TEM, Energy Dispersive X-ray Spectrometry (EDS, X-ray Diffraction (XRD analysis, and gamma spectroscopy analysis. The synthesized nanostructured radioisotope metallic oxides may be used as radiotracers in scientific, environmental, engineering, and industrial fields.

  14. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggests that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  15. Dose-on-demand production of diverse 18F-radiotracers for preclinical applications using a continuous flow microfluidic system.

    Science.gov (United States)

    Matesic, Lidia; Kallinen, Annukka; Greguric, Ivan; Pascali, Giancarlo

    2017-09-01

    The production of 18 F-radiotracers using continuous flow microfluidics is under-utilized due to perceived equipment limitations. We describe the dose-on-demand principle, whereby the back-to-back production of multiple, diverse 18 F-radiotracers can be prepared on the same day, on the same microfluidic system using the same batch of [ 18 F]fluoride, the same microreactor, the same HPLC column and SPE cartridge to obtain a useful production yield. [ 18 F]MEL050, [ 18 F]Fallypride and [ 18 F]PBR111 were radiolabeled with [ 18 F]fluoride using the Advion NanoTek Microfluidic Synthesis System. The outlet of the microreactor was connected to an automated HPLC injector and following the collection of the product, SPE reformulation produced the 18 F-radiotracer in productions for [ 18 F]MEL050 and [ 18 F]Fallypride were performed at total flow rates of 20μL/min, resulting in 40±13% and 25±13% RCY respectively. [ 18 F]PBR111 was performed at 200μL/min to obtain 27±8% RCY. Molar activities for each 18 F-radiotracer were >100GBq/μmol and radiochemical purities were >97%, implying that the cleaning procedure was effective. Using the same initial solution of [ 18 F]fluoride, microreactor, HPLC column and SPE cartridge, three diverse 18 F-radiotracers could be produced in yields sufficient for preclinical studies in a back-to-back fashion using a microfluidic system with no detectable cross-contamination. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  16. Novel methodology for the study of mercury methylation and reduction in sediments and water using 197Hg radiotracer.

    Science.gov (United States)

    Ribeiro Guevara, Sergio; Zizek, Suzana; Repinc, Urska; Pérez Catán, Soledad; Jaćimović, Radojko; Horvat, Milena

    2007-03-01

    Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H2SO4 or HCl were evaluated in freshwater sediments using 197Hg radiotracer. Values obtained for the 197Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of 197Hg2+ into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg2+ contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg2+ contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H2SO4 method is recommended, since it is free from these interferences. 197Hg radiotracer (T1/2=2.673 d) has a production rate that is about 50 times higher than that of 203Hg (T1/2=46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to 203Hg when it is used it in short-term experiments and produced by the irradiation of 196Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the 196Hg isotope is increased, the specific activity of the 197Hg tracer can be significantly improved. In the present work, 197Hg tracer was produced from mercury 51.58% enriched in the 196Hg isotope, and a 340-fold

  17. The extraction and chromatographic determination of the essentials oils from Ocimum basilicum L. by different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Soran, Maria Loredana; Varodi, Codruta; Lung, Ildiko; Surducan, Emanoil; Surducan, Vasile [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Cobzac, Simona Codruta, E-mail: loredana.soran@itim-cj.r [Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, 11 Arany Janos, 400028 Cluj-Napoca (Romania)

    2009-08-01

    Three different techniques (maceration, sonication and extraction in microwave field) were used for extraction of essential oils from Ocimum basilicum L. The extracts were analyzed by TLC/HPTLC technique and the fingerprint informations were obtained. The GC-FID was used to characterized the extraction efficiency and for identify the terpenic bioactive compounds. The most efficient extraction technique was maceration followed by microwave and ultrasound. The best extraction solvent system was ethyl ether + ethanol (1:1, v/v). The main compounds identified in Ocimum basilicum L. extracts were: {alpha} and {beta}-pinene (mixture), limonene, citronellol, and geraniol.

  18. The extraction and chromatographic determination of the essentials oils from Ocimum basilicum L. by different techniques

    International Nuclear Information System (INIS)

    Soran, Maria Loredana; Varodi, Codruta; Lung, Ildiko; Surducan, Emanoil; Surducan, Vasile; Cobzac, Simona Codruta

    2009-01-01

    Three different techniques (maceration, sonication and extraction in microwave field) were used for extraction of essential oils from Ocimum basilicum L. The extracts were analyzed by TLC/HPTLC technique and the fingerprint informations were obtained. The GC-FID was used to characterized the extraction efficiency and for identify the terpenic bioactive compounds. The most efficient extraction technique was maceration followed by microwave and ultrasound. The best extraction solvent system was ethyl ether + ethanol (1:1, v/v). The main compounds identified in Ocimum basilicum L. extracts were: α and β-pinene (mixture), limonene, citronellol, and geraniol.

  19. Posterior Segment Intraocular Foreign Body: Extraction Surgical Techniques, Timing, and Indications for Vitrectomy

    Directory of Open Access Journals (Sweden)

    Dante A. Guevara-Villarreal

    2016-01-01

    Full Text Available Ocular penetrating injury with Intraocular Foreign Body (IOFB is a common form of ocular injury. Several techniques to remove IOFB have been reported by different authors. The aim of this publication is to review different timing and surgical techniques related to the extraction of IOFB. Material and Methods. A PubMed search on “Extraction of Intraocular Foreign Body,” “Timing for Surgery Intraocular Foreign Body,” and “Surgical Technique Intraocular Foreign Body” was made. Results. Potential advantages of immediate and delayed IOFB removal have been reported with different results. Several techniques to remove IOFB have been reported by different authors with good results. Conclusion. The most important factor at the time to perform IOFB extraction is the experience of the surgeon.

  20. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  1. Assessing of bulk materials mixing and sorting by radiotracer methods

    International Nuclear Information System (INIS)

    Thyn, J.

    1983-01-01

    Various applications are indicated of tracer techniques for the evaluation of mixing and sorting of mixtures of solid particles. The evaluation of the process of mixing, i.e., the determination of the homogenization time is done by labelling of the entire volume of the monitored component of the mixture and continuous detection of radiation through the walls of the mixer using one or several detectors. The evaluation of the character of the flow and the evacuation of solid particles from the bin is done by labelling with a radiotracer the material which is spread out on the top along the whole cross-section of the bin, and the concentration is monitored of the tracer in the material outflow. The evaluation of material sorting in bins which takes place during the filling and emptying is done on the basis of significance tests or using self-correlation functions and frequency characteristics. Also monitored was the dependence of the equalizing ability of the continuous gravity mixer at the vertex angle of the tip. (M.D.)

  2. Application of 140La and 24Na as intrinsic radiotracers for investigating catalyst dynamics in FCCUs.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Nair, A G C; Tomar, B S; Nathaniel, T N; Reddy, A V R; Singh, Gursharan

    2009-09-01

    Instrumental neutron activation analysis (INAA) of fluid catalytic cracking (FCC) catalyst samples was carried out with an objective to identify activable elements and evaluate its suitability for use as an intrinsic radiotracer for tracing catalyst itself in Fluid Catalytic Cracking Units (FCCUs) used in petroleum refining. Two catalyst samples obtained from two different refineries were analyzed. Twelve different elements were identified in each catalyst sample and their respective concentrations were determined. From the recorded gamma-ray spectra, it was found that lanthanum-140 ((140)La) and sodium-24 ((24)Na) were the predominantly present and suitable radionuclides that could be used as radiotracers for tracing catalyst in FCCUs. Lanthanum being present in much higher concentration forms the major component of the radiotracer after irradiation. Based on the results of INAA, appropriate quantities of the catalyst samples were irradiated with neutrons to produce the desired amount of activity of lanthanum-140 and sodium-24 to be used as radiotracers for tracing the catalyst itself in a pilot as well as an industrial-scale FCCU. The residence time distribution (RTD) of catalyst was measured and analyzed to determine mean residence time (MRT). The axial dispersion model (ADM) was used to simulate the measured RTD data and investigate the degree of axial mixing. The results of the experiments were used to improve the design of pilot-scale FCCU and optimize the performance of the industrial-scale FCCU.

  3. A Novel Feature Extraction Technique Using Binarization of Bit Planes for Content Based Image Classification

    Directory of Open Access Journals (Sweden)

    Sudeep Thepade

    2014-01-01

    Full Text Available A number of techniques have been proposed earlier for feature extraction using image binarization. Efficiency of the techniques was dependent on proper threshold selection for the binarization method. In this paper, a new feature extraction technique using image binarization has been proposed. The technique has binarized the significant bit planes of an image by selecting local thresholds. The proposed algorithm has been tested on a public dataset and has been compared with existing widely used techniques using binarization for extraction of features. It has been inferred that the proposed method has outclassed all the existing techniques and has shown consistent classification performance.

  4. Synthesis of a new technetium radiotracer containing para-toluidine by tridentate chelation (N,N,O)

    International Nuclear Information System (INIS)

    Makhloufi, Amel

    2011-01-01

    Neuro degenerative diseases (Alzheimer, Parkinson, Creutzfeld-Jacob. and others) have an increasingly important impact as well on the economic plan as social. The diagnosis procedure and current therapies remain expensive and the assumption of responsibility of the patient is seldom assured. These last years, the development of new radiopharmaceuticals with aiming diagnosis procedure started again the interest for the search for new molecules. The asset of the synthesis of our technetium radiotracer, a tridentate chelate complex (N, N, O) resides in the facility of its obtaining; marking with the kit Alberto is done at a temperature about 90 degree approximately and this could consequently facilitate its implementation in the units of radiodiagnosis. Of lipophilic nature, neutral and of suitable molecular weight, the main challenge for this molecule would be to check its capacity to cross the blood-brain barrier by studying its cerebral extraction.

  5. Radiotracer technique to study pollutant behavior in the vadose zone for groundwater protection

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sinha, U.K.; Navada, S.V.; Datta, P.S.; Sud, Y.K.; Kulkarni, K.M.; Aggrawal, P.; )

    2004-01-01

    Pollutants are generated either by industrial or agricultural activity. Pollutants produced due to industrial activities fall into point source category and those generated from agricultural are grouped into extended source category. Under an International Atomic Energy Agency/Coordinated Research Program study, emphasis has been given on transport of pollutants, generated from agricultural activities, in particular, due to the application of fertilizer inputs to a variety of crops. Pollutants take entry through the vadose zone and ultimately join the saturated zone. Once groundwater is polluted it is rather difficult or impossible to take remedial measures for groundwater protection. Groundwater being an important natural resource, it is important to protect it from getting polluted. It is hence essential to have a clear understanding of the complex processes (physical, biological and chemical etc.) undergoing in the unsaturated zone. Radiotracers give good insight about the pollutant behavior in the vadose zone. Tritiated water and 60 Co (a gamma emitting tracer in the cyanide complex form) were used as tracers and were injected at 60 cm depth in the vadose zone of IARI farm for pollutant transport study. Tritium and 60 Co tracer displacements were measured by liquid scintillation and sodium iodide scintillation method respectively. It was found that the tritium tracer moved up to 2.4 meters in six months and part of the tritium tracer was exchanged with immobile water in the soil, as three distinct peaks were observed in tritium profile. 60 Co and tritium tracers were found to move with the same velocity in the vadose zone. These tracer studies indicate that the pollutants may reach the groundwater in about three years. (author)

  6. Impact of extraction techniques on antioxidant capacities and phytochemical composition of polyphenol-rich extracts.

    Science.gov (United States)

    Castro-López, Cecilia; Ventura-Sobrevilla, Janeth M; González-Hernández, María D; Rojas, Romeo; Ascacio-Valdés, Juan A; Aguilar, Cristóbal N; Martínez-Ávila, Guillermo C G

    2017-12-15

    In this work, impact of extraction methods (maceration, decoction, MAE, and UAE) on TPC, antioxidant activity, and the mass fraction of phenolics in several plant extracts (Punica granatum, Juglans regia, Moringa oleifera, and Cassia fistula) was investigated. The results showed that, despite the nature of matrix, the highest values of TPC in all samples were obtained by MAE as follows: PP (18.92±0.11), ML (15.19±0.11), HL (12.69±0.16), and WS (12.80±0.11) mg GAEg -1 respectively, and exhibited potent antioxidant activity (from 0.28±0.01 to 5.34±0.02mgGAEg -1 ), representing sources of powerful antioxidants. The LC-MS 2 analysis revealed a wide range of phenolics, highlighting their content in phenolic acids, flavonoids and lignans. The presence of different phenol molecules demonstrated that the extraction method had influence on phytochemical profile. Finally, due to its high extraction efficiency, MAE was the more effective extraction technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer

    International Nuclear Information System (INIS)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W.M.M.; Wiegerinck, Peter H.G.; Pietzsch, Jens; Bergmann, Ralf

    2009-01-01

    The radiosynthesis of [N-methyl- 11 C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [ 11 C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23±5% (decay-corrected, based upon [ 11 C]CO 2 ) at a specific activity of 47±12 GBq/μmol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl- 11 C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl- 11 C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl- 11 C]Org 34850 may still represent a suitable candidate for imaging GRs in humans

  8. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer.

    Science.gov (United States)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W M M; Wiegerinck, Peter H G; Pietzsch, Jens; Bergmann, Ralf

    2009-02-01

    The radiosynthesis of [N-methyl-(11)C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [(11)C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23+/-5% (decay-corrected, based upon [(11)C]CO(2)) at a specific activity of 47+/-12 GBq/micromol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl-(11)C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl-(11)C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl-(11)C]Org 34850 may still represent a suitable candidate for imaging GRs in humans.

  9. Direct hair transplantation: A modified follicular unit extraction technique

    Directory of Open Access Journals (Sweden)

    Pradeep Sethi

    2013-01-01

    Full Text Available Background: In hair transplantation, the survival rate of harvested grafts depends upon many factors like maintenance of hydration, cold temperature, reduced mechanical handling and asepsis. All these factors are favourably improved if time out of body is reduced significantly. We have tried a modification called direct hair transplantation in the existing follicular unit extraction technique, in which the follicular unit grafts are implanted as soon as they are harvested. In this article, we have described the detailed methodology and a series of 29 patients who underwent direct hair transplantation. Aim: To evaluate the efficacy and feasibility of direct hair transplantation. Subjects and Methods: The patients willing to undergo hair transplantation by the technique of follicular unit extraction were enrolled for the surgery. After administration of local anaesthesia, the recipient sites were created. Thereafter, the processes of scoring the skin with a motorized punch, graft extraction and implantation were performed simultaneously. These patients were followed up to look for the time period of initiation of hair growth, the growth achieved at the end of 6-8 months and any adverse events. The results of patients with noticeable improvement in the photographs and reduction in baldness grade were taken as ′good′, whereas, in other patients, it was classified as ′poor′. Results: All patients were males with age ranging from 21 to 66 years (median 30 years. Twenty-six patients had androgenetic alopecia, 1 patient had traction alopecia and 2 patients had scarring alopecia. Twenty-seven patients showed ′good′ results, whereas 2 patients showed ′poor′ results. Conclusion: Direct hair transplantation is a simple and feasible modification in the follicular unit extraction technique. It is an efficacious surgical treatment modality for baldness.

  10. Comparison between several techniques of olive tree bark extraction (Tunisian Chemlali variety).

    Science.gov (United States)

    Issaoui, Aimen; Ksibi, Hatem; Ksibi, Mohamed

    2017-01-01

    In order to better understand the chemical composition of the olive tree bark of Tunisian chemlali variety (Olea europaea cv. 'Chemlali'), this material was extracted by different ways. Compositions of extracts were used at best-selected conditions for each technique, and characterised using HPLC, LC/MS and GC-MS techniques. Analyses are conducted to an important variety of high carbon number compounds such as aliphatic compounds as nanocosane and heptacosane, and molecules with high value added tax (VAT) which can be classified as follows: diterpenes as phytol, triterpenes as squalene and also esters as Benzyl cinnamate. Hydrodistillation at high pressure seems to be a very common method to get a wide variety of compounds, the results are better than the ones obtained using supercritical fluid extraction and solvent extraction.

  11. Investigation of flow dynamics of liquid phase in a pilot-scale trickle bed reactor using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K

    2016-10-01

    A radiotracer investigation was carried out to measure residence time distribution (RTD) of liquid phase in a trickle bed reactor (TBR). The main objectives of the investigation were to investigate radial and axial mixing of the liquid phase, and evaluate performance of the liquid distributor/redistributor at different operating conditions. Mean residence times (MRTs), holdups (H) and fraction of flow flowing along different quadrants were estimated. The analysis of the measured RTD curves indicated radial non-uniform distribution of liquid phase across the beds. The overall RTD of the liquid phase, measured at the exit of the reactor was simulated using a multi-parameter axial dispersion with exchange model (ADEM), and model parameters were obtained. The results of model simulations indicated that the TBR behaved as a plug flow reactor at most of the operating conditions used in the investigation. The results of the investigation helped to improve the existing design as well as to design a full-scale industrial TBR for petroleum refining applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Technique of calculating specific capital investments in the fuel extracting sectors of industry

    Energy Technology Data Exchange (ETDEWEB)

    Bugrov, V.A.; Filey, I.A.

    1980-01-01

    An analysis is made of the existing methods of calculating specific capital investments in the fuel extracting sectors of industry. Their shortcomings are shown. It is suggested that specific capital investments for extraction of coal and gas be defined as the ratio of capital investments to the conditional increase in extraction. Coal extraction should take int consideration all the capital investments associated with the input of new facilities, and the maintenance of the attained level of extraction and reconstruction of the enterprise, as well as all the newly introduced facilities both at the new and at the active enterprises associated with an increase in coal extraction and with maintenance of the facilities. The suggested technique completely corresponds to the ''Standard Technique for Developing a Technical-Industrial-Financial Plan,'' which stipulates determination of specific capital investments per unit of introduced facilities with only the difference that it takes into consideration the specific features of the fuel extracting sectors of industry.

  13. Quantitative evaluation of environmental factors influencing the dynamics of mercury in the aquatic systems. Highlights and achievements

    International Nuclear Information System (INIS)

    Akagi, Hirokatsu

    2002-01-01

    The development of a combined mercury extraction - speciation technique for total mercury and methylinercury determination in various biological and environmental media have been established to study and evaluate environmental factors influencing the dynamics of mercury in aquatic systems. Comparability studies of the results from the conventional and radiochemical techniques were planned for the 1st year of the CRP. Validation of the radiochemical method will be undertaken during the current CRP because of constraints in obtaining the appropriate radiotracers. The use of radiotracer techniques will be undertaken to investigate the generation and distribution of methylmercury in the river water - sediment systems using 203 Hg. The improved conventional analytical procedure uses the cold vapor atomic absorption spectrometry for the determination of total mercury in biological and environmental samples. For methylmercury determination, samples are analyzed using combined techniques of dithizone extraction and gas chromatograpy with electron capture detection

  14. Application of radiotracers in an exotic field of botany. How to feed carnivorous plants

    International Nuclear Information System (INIS)

    Steinhauser, G.; Musilek, A.; Sterba, J.H.; Bichler, M.; Adlassnig, W.; Peroutka, M.; Lichtscheidl, I.K.

    2007-01-01

    In this paper, methods for the application of radiotracers in the Cobra Lily (Darlingtonia californica), a carnivorous pitcher plant, are described. The uptake of radiotracers such as 42 K and 54 Mn into the pitcher trap in aqueous solution could be proven, whereas uptake of 59 Fe ions could not be observed. No-carrier-added 54 Mn was taken up by the plants, regardless of extremely low concentrations. In contrast to earlier experiments using 14 C and 15 N-based tracers, the methodology presented allows quick, simple and reliable quantification of the nutrient uptake. The results of our experiments lead to a deeper biological understanding concerning the trace element household of this carnivorous plant and the absorption of micro- and macronutrients from trapped prey. (author)

  15. Radiotracer applications in industry - A guidebook

    International Nuclear Information System (INIS)

    2004-01-01

    The objective of this guidebook is to provide the radiotracer practitioner with practical, experience based information about all the facets of an investigation: design, planning, implementation, data treatment and interpretation of results. It is aimed at clearly identifying the questions that need to be asked at each stage of the investigation and, as comprehensively as possible, to either provide the answers to those questions or identify appropriate works of reference. The primary focus is on the methodology of radio tracing. Discussed aspects of the methodology are: tracer selection and optimization, methods of tracer injection, detection and measurement of radiation, data treatment and filtering including identification of available software, data analysis, interpretation and modelling. An early consideration in designing an investigation is selection of the tracer. The criteria of critical importance are that (1) the tracer must be compatible with the stream to be traced and (2) its behaviour must be representative of that stream. The first decision to make is whether to use a radioactive tracer or some alternative type. Generally, if the objectives of the investigation can be achieved using a non-radioactive tracer and without incurring disproportionate costs, then that tracer should be used. However, as will become apparent from the case studies presented, there are many problems that can be investigated only by using a radiotracer. In these cases it is necessary to choose a tracer based on the following selection criteria: type of radiation emitted: alpha particle, beta particle or gamma ray, half-life of the radionuclide, energy of the emitted radiation and optimization of the activity injected. The methodology reviewed considers the most commonly used radioisotopes for tracing solid materials, aqueous solutions, organic liquids and gaseous phases. The main emphasis is on the practical aspects of the technology. Various types of injection system are

  16. Radiotracer study on the efficiency of a cylindrical 2-stage anaerobic sludge digester

    International Nuclear Information System (INIS)

    Sung-Hee Jung; Joon-Ha Jin; Jong-Bum Kim

    2004-01-01

    Radiotracer experiments were carried out on a cylindrical 2-stage anaerobic sludge digester in order to investigate the improvement of their efficiency by means of RTD (residence time distribution) measurements before and after cleaning up the inside of the digester. The tracer was scandium in an EDTA solution which forms such a stable complex compound to keep the isotope form being adsorbed onto the surface of the pipelines or the wall. It was injected into the digester by pressurized nitrogen gas and its movement was monitored by NaI(Tl) scintillation detectors installed around the digester and recorded for a month by a 24-channel data acquisition system specially developed for radiotracer experiments by the Korea Tracer Group of KAERI. The experimental data was analysed for the MRT (mean residence time) and other parameters characterizing the flow behaviour. (author)

  17. The applicability of radiotracers for the investigation of the distillation of hydrocarbons

    International Nuclear Information System (INIS)

    Graczyk, J.; Iller, E.

    1976-01-01

    The use of radioactive tracers provide valuable methods for the investigation of distillation processes and have been applied to determine the characteristics of material streams, the dynamics of flowing phases and the composition in various parts of the distillation equipment. A method is proposed for testing individual radiotracers emplozemployed for the investigation of the distillation of hydrocarbons. The method consists in laboratory-scale distillation of a tracer together with a multicomponent hydrocarbon mixture, namely a gasoline fraction. The purification efficiency, distillation characteristics, and effective radiochemical purity of several tracers (reactor activated bromobenzene and synthesized C 3 H 7 82 Br, C 4 H 9 82 Br, C 5 H 11 82 Br) have been investigated. The distillation characteristics of bromohydrocarbons labelled with 82 Br and selected hydrocarbons tagged with 14 C (benzene and cumene) have been compared. The radiotracers investigated were employed for the determination of the hydrodynamic parameters of hydrocarbon distillation in laboratory packed columns and a commercial distillation tower. (author)

  18. Simple, Safe, and Cost-Effective Technique for Resected Stomach Extraction in Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Derici, Serhan; Atila, Koray; Bora, Seymen; Yener, Serkan

    2016-01-01

    Background. Laparoscopic sleeve gastrectomy (LSG) has become a popular operation during the recent years. This procedure requires resection of 80-90% of the stomach. Extraction of gastric specimen is known to be a challenging and costly stage of the operation. In this paper, we report results of a simple and cost-effective specimen extraction technique which was applied to 137 consecutive LSG patients. Methods. Between October 2013 and October 2015, 137 laparoscopic sleeve gastrectomy surgeries were performed at Dokuz Eylul University General Surgery Department, Upper Gastrointestinal Surgery Unit. All specimens were extracted through a 15 mm trocar site without using any special device. Results. We noticed one superficial incisional surgical site infection and treated this patient with oral antibiotics. No cases of trocar site hernia were observed. Conclusion. Different techniques have been described for specimen extraction. This simple technique allows extraction of specimen safely in a short time and does not require any special device.

  19. Radiotracer measurements as a sensitive tool for the detection of metal penetration in molecular-based organic electronics

    International Nuclear Information System (INIS)

    Scharnberg, M.; Hu, J.; Kanzow, J.; Raetzke, K.; Adelung, R.; Faupel, F.; Pannemann, C.; Hilleringmann, U.; Meyer, S.; Pflaum, J.

    2005-01-01

    The metallization of organic thin films is a crucial point in the development of molecular electronics. However, there is no method established yet to detect trace amounts of metal atoms in those thin films. Radiotracer measurements can quantify even very small amounts of material penetrating into the bulk, in our case less than 0.01% of a monolayer. Here, the application of this technique on two different well-characterized organic thin film systems (diindenoperylene and pentacene) is demonstrated. The results show that Ag is mainly adsorbed on the surface, but indicate that already at moderate deposition temperatures Ag can penetrate into the organic thin films and agglomerate at the film/substrate interface

  20. [Aging Law of PAHs in Contaminated Soil and Their Enrichment in Earthworms Characterized by Chemical Extraction Techniques].

    Science.gov (United States)

    Zhang, Ya-nan; Yang, Xing-lun; Bian, Yong-rong; Gu, Cheng-gang; Liu, Zong-tang; Li, Jiao; Wang, Dai-zhang; Jiang, Xin

    2015-12-01

    To evaluate the effect of aging on the availability of PAHs, chemical extraction by exhaustive ( ASE extraction) and nonexhaustive techniques (Tenax-TA extraction, hydroxypropyl-p-cyclodextrin ( HPCD ) extraction, n-butyl alcohol ( BuOH) extraction) as well as PAHs accumulation in earthworms (Eisenia fetida) were conducted in yellow soil from Baguazhou, Nanjing, China, and red soil from Hainan, China, spiked with phenanthrene, pryene and benzo(a) pyrene and aged 0, 7, 15, 30 and 60 days. The results showed that the concentration of PAHs extracted by ASE and three nonexhaustive techniques and accumulated by earthworms significantly decreased with aging time, except the ASE extracted concentration between 30-and 60-day aging time. Furthermore, the relationships were studied in this experiment between chemical extracted PAHs concentration and accumulated concentration in earthworms. PAHs accumulated concentration in earthworms was not significantly correlated with the exhaustive extracted concentration of PAHs in soil (R² 0.44-0.56), which indicated that ASE extraction techniques could not predict PAHs bioavailability to earthworms because it overestimated the risk of PAHs. However, the PAHs accumulated concentration in earthworms was significantly correlated with the three nonexhaustive extracted concentrations of PAHs in soil, which indicated that all the three nonexhaustive techniques could predict PAHs bioavailability to earthworm to some extent, among which, HPCD extraction (R² 0.94-0.99) was better than Tenax-TA extraction (R² 0.62-0.87) and BuOH extraction (R² 0.69-0.94). So HPCD extraction was a more appropriate and reliable technique to predict bioavailability of PAHs in soil.

  1. Hydrolysis studies of thorium using solvent extraction technique

    International Nuclear Information System (INIS)

    Engkvist, I.; Albinsson, Y.

    1992-01-01

    The Swedish concept for final disposal of spent nuclear fuel is focused on a repository in crystalline rock at a depth of 500 m. In order to calculate migration rates from such a repository, chemical speciation becomes important. A method for determining complexation of actinides and lanthanides with inorganic ligands using solvent extraction has been developed. The apparatus used is called AKUFVE and the used technique can measure distribution values in a two liquid phase system in the range 10 -5 to 10 5 , pH 1 to 11. Hydrolysis of thorium has been studied in 1 M NaClO 4 in inert atmosphere. Th-234 separated from U-238 was extracted with 0.01-1 M 2,4-pentanedione (HAa) in toluene. From extraction data, calculations of hydrolysis constants have been made, regarding hydroxide complexes as competing and nonextractable. As a result we conclude that the constant for tri- and tetrahydroxide complexes are overestimated. (orig.)

  2. Some Examples of Residence-Time Distribution Studies in Large-Scale Chemical Processes by Using Radiotracer Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bullock, R. M.; Johnson, P.; Whiston, J. [Imperial Chemical Industries Ltd., Billingham, Co., Durham (United Kingdom)

    1967-06-15

    The application of radiotracers to determine flow patterns in chemical processes is discussed with particular reference to the derivation of design data from model reactors for translation to large-scale units, the study of operating efficiency and design attainment in established plant and the rapid identification of various types of process malfunction. The requirements governing the selection of tracers for various types of media are considered and an example is given of the testing of the behaviour of a typical tracer before use in a particular large-scale process operating at 250 atm and 200 Degree-Sign C. Information which may be derived from flow patterns is discussed including the determination of mixing parameters, gas hold-up in gas/liquid reactions and the detection of channelling and stagnant regions. Practical results and their interpretation are given in relation to an define hydroformylation reaction system, a process for the conversion of propylene to isopropanol, a moving bed catalyst system for the isomerization of xylenes and a three-stage gas-liquid reaction system. The use of mean residence-time data for the detection of leakage between reaction vessels and a heat interchanger system is given as an example of the identification of process malfunction. (author)

  3. In Vivo Metabolic Trapping Radiotracers for Imaging Monoamine Oxidase-A and –B Enzymatic Activity

    Science.gov (United States)

    Brooks, Allen F.; Shao, Xia; Quesada, Carole A.; Sherman, Phillip; Scott, Peter J.H.; Kilbourn, Michael R.

    2017-01-01

    The isozymes of monoamine oxidase (MAO-A and MAO-B) are important enzymes involved in the metabolism of numerous biogenic amines, including the neurotransmitters serotonin, dopamine and norepinephrine. Recently, changes in concentrations of MAO-B have been proposed as an in vivo marker of neuroinflammation associated with Alzheimer’s disease. Previous developments of in vivo radiotracers for imaging changes in MAO enzyme expression or activity have utilized the irreversible propargylamine-based suicide inhibitors, or high-affinity reversibly-binding inhibitors. As an alternative approach, we have investigated 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines as metabolic trapping agents for the monoamine oxidases. MAO-mediated oxidation and spontaneous hydrolysis yields 1-[11C]methyl-2,3-dihydro-4-pyridinone as a hydrophilic metabolite that is trapped within brain tissues. Radiotracers with phenyl, biphenyl and 7-coumarinyl ethers were evaluated using microPET imaging in rat and primate brain. No isozyme selectivity for radiotracer trapping was observed in the rat brain for any compound, but in the monkey brain the phenyl ether demonstrated MAO-A selectivity, and the coumarinyl ether showed MAO-B selectivity. These are lead compounds for further development of 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines with optimized brain pharmacokinetics and isozyme selectivity. PMID:26393369

  4. Chemical fate of the nicotinic acetylcholinergic radiotracer [123I]5-IA-85380 in baboon brain and plasma

    International Nuclear Information System (INIS)

    Baldwin, Ronald M.; Zoghbi, Sami S.; Staley, Julie K.; Brenner, Eric; Al-Tikriti, Mohammed S.; Amici, Louis; Fujita, Masahiro; Innis, Robert B.; Tamagnan, Gilles

    2006-01-01

    The fate of the nicotinic acetylcholinergic receptor radiotracer [ 123 I]5-IA-85380 ([ 123 I]5-IA) was studied in baboon by analyzing the chemical composition of brain tissue and plasma after intravenous administration of the tracer. Acetonitrile denaturation and high-performance liquid chromatography (HPLC) analysis showed predominantly unchanged (91-98%) parent tracer in all brain tissues examined, compared to significant metabolism (23% parent) in the plasma at 90 min postinjection, and control tissue recovery of 95-98%. [ 123 I]5-IA was distributed to the thalamus with a standardized uptake value of 9.2 (0.04% dose/g) or a concentration 5.8 times higher than that of the cerebellum. The HPLC behavior of a synthesized sample of one hypothesized metabolite, 5-iodo-3-pyridinol (5-IP), was consistent with plasma radiometabolite fraction. Since only parent radiotracer compound was found in brain tissue, these results add confidence that information derived from single photon emission computed tomography images of 123 I activity in the brain after [ 123 I]5-IA administration can be interpreted as distribution of an intact radiotracer

  5. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    The seasonal variation in sulfate reduction and the dynamics of sulfur and iron geochemistry were studied throughout a year in sediment of Aarhus Bay, Denmark. A radiotracer method for measuring sulfate reduction rates was applied with incubation times down to 15 min and a depth resolution down...... to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  6. Antifungal activity of extracts from Piper aduncum leaves prepared by different solvents and extraction techniques against dermatophytes Trichophyton rubrum and Trichophyton interdigitale.

    Science.gov (United States)

    Santos, Maximillan Leite; Magalhães, Chaiana Froés; da Rosa, Marcelo Barcellos; de Assis Santos, Daniel; Brasileiro, Beatriz Gonçalves; de Carvalho, Leandro Machado; da Silva, Marcelo Barreto; Zani, Carlos Leomar; de Siqueira, Ezequias Pessoa; Peres, Rodrigo Loreto; Andrade, Anderson Assunção

    2013-12-01

    The effects of different solvents and extraction techniques upon the phytochemical profile and anti-Trichophyton activity of extracts from Piper aduncum leaves were evaluated. Extract done by maceration method with ethanol has higher content of sesquiterpenes and antifungal activity. This extract may be useful as an alternative treatment for dermatophytosis.

  7. Kinetics studies of solvent extraction of rare earths into DEHPA

    International Nuclear Information System (INIS)

    Lim, T.M.; Tran, T.

    1996-01-01

    The kinetics of rare earth solvent extraction into di(2-ethylhexyl) phosphoric acid have been studied using radiotracers ( 141 Ce, 152 Eu, 153 Gd, 160 Tb and 88 Y) in a modified Lewis cell. The experimental procedure involved continuous monitoring of both aqueous and organic phases using an automated γ- counting system. Using this method, highly reproducible results were obtained without chemical analysis or disturbance of the system. The initial rate extraction was first order with respect to individual rare earth concentration. At low acidities ([H+] < 0.01 M), the extraction rates of rare earths were equal and independent of pH. However, at high acidities, the extraction rate was strongly dependent on pH and varied between the rare earths. Similarly, differences in the extraction rate of individual rare earths were apparent at low DEHPA concentration. (authors)

  8. A histogram-based technique for rapid vector extraction from PIV photographs

    Science.gov (United States)

    Humphreys, William M., Jr.

    1991-01-01

    A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

  9. Extraction of Natural Antioxidants from the Thelephora ganbajun Mushroom by an Ultrasound-Assisted Extraction Technique and Evaluation of Antiproliferative Activity of the Extract against Human Cancer Cells

    Directory of Open Access Journals (Sweden)

    Dong-Ping Xu

    2016-10-01

    Full Text Available The Thelephora ganbajun mushroom has been found to be a potential rich source of natural antioxidants. In this study, an ultrasound-assisted extraction (UAE technique together with GRAS (generally recognized as safe solvents (ethanol and water was used to maximize the extraction of antioxidants from Thelephora ganbajun. Five extraction parameters (ethanol concentration, solvent to solid ratio, extraction time, temperature and ultrasound power were investigated by single-factor experiments, and then a central composite rotatable design was employed to study interaction of three key extraction parameters. The optimum conditions were as follows: 57.38% ethanol, 70.15 mL/g solvent to solid ratio, 10.58 min extraction time, 40 °C extraction temperature and 500 W ultrasound power. Under the optimum conditions, the antioxidant activity obtained was 346.98 ± 12.19 µmol Trolox/g DW, in accordance with the predicted value of 344.67 µmol Trolox/g DW. Comparison of UAE with conventional maceration and Soxhlet extraction, the UAE method showed stronger extract efficiency in a shorter extraction time. These results showed that UAE was an effective technique to extract antioxidants from Thelephora ganbajun. Furthermore, the extracts obtained under the optimized conditions exhibited antiproliferative activities toward human lung (A549, breast (MCF-7, liver (HepG2 and colon (HT-29 cancer cells, especially for liver and lung cancer cells. In addition, rutin, 2-hydrocinnamic acid and epicatechin were identified in the extract, which might contribute to antioxidant and antiproliferative activities.

  10. Extraction of Natural Antioxidants from the Thelephora ganbajun Mushroom by an Ultrasound-Assisted Extraction Technique and Evaluation of Antiproliferative Activity of the Extract against Human Cancer Cells.

    Science.gov (United States)

    Xu, Dong-Ping; Zheng, Jie; Zhou, Yue; Li, Ya; Li, Sha; Li, Hua-Bin

    2016-10-01

    The Thelephora ganbajun mushroom has been found to be a potential rich source of natural antioxidants. In this study, an ultrasound-assisted extraction (UAE) technique together with GRAS (generally recognized as safe) solvents (ethanol and water) was used to maximize the extraction of antioxidants from Thelephora ganbajun . Five extraction parameters (ethanol concentration, solvent to solid ratio, extraction time, temperature and ultrasound power) were investigated by single-factor experiments, and then a central composite rotatable design was employed to study interaction of three key extraction parameters. The optimum conditions were as follows: 57.38% ethanol, 70.15 mL/g solvent to solid ratio, 10.58 min extraction time, 40 °C extraction temperature and 500 W ultrasound power. Under the optimum conditions, the antioxidant activity obtained was 346.98 ± 12.19 µmol Trolox/g DW, in accordance with the predicted value of 344.67 µmol Trolox/g DW. Comparison of UAE with conventional maceration and Soxhlet extraction, the UAE method showed stronger extract efficiency in a shorter extraction time. These results showed that UAE was an effective technique to extract antioxidants from Thelephora ganbajun . Furthermore, the extracts obtained under the optimized conditions exhibited antiproliferative activities toward human lung (A549), breast (MCF-7), liver (HepG2) and colon (HT-29) cancer cells, especially for liver and lung cancer cells. In addition, rutin, 2-hydrocinnamic acid and epicatechin were identified in the extract, which might contribute to antioxidant and antiproliferative activities.

  11. Antifungal activity of extracts from Piper aduncum leaves prepared by different solvents and extraction techniques against dermatophytes Trichophyton rubrum and Trichophyton interdigitale

    Directory of Open Access Journals (Sweden)

    Maximillan Leite Santos

    2013-12-01

    Full Text Available The effects of different solvents and extraction techniques upon the phytochemical profile and anti-Trichophyton activity of extracts from Piper aduncum leaves were evaluated. Extract done by maceration method with ethanol has higher content of sesquiterpenes and antifungal activity. This extract may be useful as an alternative treatment for dermatophytosis.

  12. Nuclear techniques in agriculture and industry in China

    International Nuclear Information System (INIS)

    Lu Yanxiao

    1993-01-01

    The presentation describes the application of nuclear techniques related to information acquisition by radiotracer and isotope-instrument getting physical parameters from measured substances, medical diagnostic information, evolution of novel substances or modification of materials through interaction of ionizing radiation with matter,mutation breeding in agriculture, cancer therapy in medicine, sterilization of medical products

  13. Status and trends in nuclear techniques in the mineral industry in India

    International Nuclear Information System (INIS)

    Eapen, A.C.; Rao, S.M.; Murthy, T.S.

    1991-01-01

    The status and use of nuclear techniques in the various parts of the mineral industry in India are reviewed. The techniques and applications include nucleonic level control in ore hoppers; radiometric density gauges; coal ash monitoring using x-ray backscattering; mineral analysis by x-ray fluorescence and radioisotope analysis; neutron and gamma logging of oil wells; radiotracer techniques in bauxite processing and in the oil industry. (UK)

  14. Accelerated solvent extraction (ASE) - a fast and automated technique with low solvent consumption for the extraction of solid samples (T12)

    International Nuclear Information System (INIS)

    Hoefler, F.

    2002-01-01

    Full text: Accelerated solvent extraction (ASE) is a modern extraction technique that significantly streamlines sample preparation. A common organic solvent as well as water is used as extraction solvent at elevated temperature and pressure to increase extraction speed and efficiency. The entire extraction process is fully automated and performed within 15 minutes with a solvent consumption of 18 ml for a 10 g sample. For many matrices and for a variety of solutes, ASE has proven to be equivalent or superior to sonication, Soxhlet, and reflux extraction techniques while requiring less time, solvent and labor. First ASE has been applied for the extraction of environmental hazards from solid matrices. Within a very short time ASE was approved by the U.S. EPA for the extraction of BNAs, PAHs, PCBs, pesticides, herbicides, TPH, and dioxins from solid samples in method 3545. Especially for the extraction of dioxins the extraction time with ASE is reduced to 20 minutes in comparison to 18 h using Soxhlet. In food analysis ASE is used for the extraction of pesticide and mycotoxin residues from fruits and vegetables, the fat determination and extraction of vitamins. Time consuming and solvent intensive methods for the extraction of additives from polymers as well as for the extraction of marker compounds from herbal supplements can be performed with higher efficiencies using ASE. For the analysis of chemical weapons the extraction process and sample clean-up including derivatization can be automated and combined with GC-MS using an online ASE-APEC-GC system. (author)

  15. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.

  16. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of 11 C, 18 F and 13 N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume

  17. Using geoelectrochemical technique to extract uranium and other metals

    International Nuclear Information System (INIS)

    Gao Yulong

    1990-10-01

    The geoelectrochemical extraction technique, which is a direct deep exploring method, is one of the geoelectrochemical exploring methods. It is developed recently to explore basic metals, precious metals, rare metals and some nonmetal mineral products. It is also a combination of electrical surveying and geochemical surveying. This method is more useful in the seeking of gold ore deposit. The principle and technique of this method and the results in seeking gold, uranium, lead, nickel and tin ore deposits are introduced. The equipment and instruments used in this method are also given

  18. Development of gold nanoparticle radiotracers for investigating multiphase system in process industries

    International Nuclear Information System (INIS)

    Mohd Amirul Syafiq Mohd Yunos; Jaafar Abdullah; Engku Fahmi Engku Chik; Noraishah Othman

    2010-01-01

    This paper describes the development of colloidal 197 Au-SiO 2 with core-shell structure nanoparticle radiotracers. Using conventional citrate-reduction method, gold nanoparticles were prepared from its corresponding metal salts in aqueous solution then coated with uniform shells of amorphous silica via a sol-gel reaction. This target material of radiotracer application used to investigate multiphase system in process industries without disturbing the system operation. The citrate-reduction-based method provides gold nanoparticles with higher concentration and narrow size distribution. By using transmission electron microscopy (TEM), the resultant of particle size and silica coatings could be varied from tens to several hundred of nanometers by controlling the catalyzer and precipitation time. 197 Au-SiO 2 core-shell nano structure is good to prevent the particles from getting conglomerate resulting in a big mass. In addition, silica surface offer very good chances that make the hydrophobicity behavior on the gold nanoparticles. EDXRF spectrum has proven that 197 Au-SiO 2 core-shell nanoparticles sample consists purely of a gold and silica particles. (author)

  19. The effect of the extraction techniques on the kinetics, yield and antioxidative activity of ethyl acetate extracts of Hieracium pilosella L.

    OpenAIRE

    Stanojević, Ljiljana P.; Stanković, Mihajlo Z.; Veljković, Vlada; Cakić, Milorad D.; Nikolić, Vesna D.; Ilić, Dušica P.

    2011-01-01

    The influence of three extraction techniques (Reflux maceration, Soxhlet and Tillepape extraction) on the kinetics, yield and antioxidant activity of ethyl acetate extracts of Hieracium pilosella L. was investigated. The antioxidant activity of the extracts on stable 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical was determined spectrophotometrically. The total phenolic content was determined by using the Folin-Ciocalteu assay and the total flavonoids content was measured by spectrophotometric...

  20. [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine receptors using single photon emission computer tomography; [{sup 123}I]-3-Iodcytisin als moeglicher Radiotracer fuer die Darstellung der nikotinergen Acetylcholin Rezeptoren mittels Single-Photon-Emissions-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Paulik, Dagmar Julia

    2015-03-06

    For the synthesis of [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine (nACh) receptors using SPECT two different technologies were used: the radio-iodination with iodogen and the radio-iodination with nitric acid. The latter one showed higher efficiency. The radiotracer will allow to detect degenerative processes and other nACh-depending diseases in the brain (Alzheimer, Parkinson) and to observe the progress. The autoradiography is aimed to the imaging of the nACh receptors in the brain bypassing the brain-blood barrier. The highest activity was measured in the thalamus of mice and rat brains.

  1. Study of regional pulmonary gas exchange using radiotracers

    International Nuclear Information System (INIS)

    Hichwa, R.D.

    1981-01-01

    Respiration involves the exchange of gases between the environment and the blood across the alveolar membrane. Four processes characterize the dynamics of gas exchange: ventilation, diffusion, perfusion and chemical binding with hemoglobin. A study was undertaken to investigate each of these processes, utilizing accelerator production and high yield synthesis of four gaseous radiotracers (/sup 81m/Kr, Ch 3 18 F, 11 CO, 15 O 2 ). Conventional gamma camera images and ancillary physiological data were acquired. Mathematical models were developed to predict the tracer clearance from the lungs during a breath hold and during washout post breath hold. Images of the insoluble /sup 81m/Kr synchronized with the tidal breathing maneuver depict regional ventilation. Tracer bolus inhalation, relative compliance and regional phase information are obtained from krypton dCynamic studies. More soluble CH 3 18 F is used to determine regional pulmonary perfusion during a breath hold. Respiratory clearance of seven, inert, positron-emitting radiotracers define the tracer volume of distribution. The tight-binding of 11 CO to hemoglobin permits the regional measurement of carbon monoxide pulmonary diffusion capacity. A relative CO blood:gas partition coefficient is calculated from the washout of no-carrier-added levels of 11 CO and verified by in vitro radiometric measurements. Regional oxygen pulmonary diffusion capacity determined from 15 O 2 clearance during a breath hold reveals results similar to those obtained with CO. All experimental data are in good agreement with the predictions of a two-compartment open model. A more advanced oxygen model is presented that incorporates radioactive oxygen exchange with stable oxygen on the hemoglobin molecule and metabolic removal of the tracer at the tissues

  2. National symposium: nuclear technique in industry, medicine, agriculture and environment protection. Abstracts of papers; Krajowe sympozjum: technika jadrowa w przemysle, medycynie, rolnictwie i ochronie srodowiska. Streszczenia referatow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The National Symposium `Nuclear Techniques in Industry, Medicine, Agriculture and Environment Protection` has been held in Rynia near Warsaw from 24 to 27 April 1995. Totally 94 lectures have been presented. The actual state of art in Polish investigations have been shown in all branches of applied nuclear sciences. The plenary session devoted to general topics has began the symposium. Further conference has been divided into 18 subject sessions. There were: (1) radiation technologies in environment protection; (2) radiation technologies in materials engineering; (3) radiation preservation in food; (4) radiation techniques for medical use; (5) radiotracers in industrial investigations; (6) radiotracers in water and sewage management and leak control; (7) tracers in hydrology; (8) radiotracers in materials testing; (9) instruments for environment protection, (10) radiometric industrial gages; (11) diagnostic and testing instruments; (12) application of nuclear techniques in materials testing; (13) applications of nuclear techniques in geology and hydrogeology; (14) radioanalytical methods; (15) radiation detectors; (16) radiation measurements; (17) data processing from radiometric experiments; (18) accelerators, isotopes manufacturing, INIS.

  3. National symposium: nuclear technique in industry, medicine, agriculture and environment protection. Abstracts of papers; Krajowe sympozjum: technika jadrowa w przemysle, medycynie, rolnictwie i ochronie srodowiska. Streszczenia referatow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The National Symposium `Nuclear Techniques in Industry, Medicine, Agriculture and Environment Protection` has been held in Rynia near Warsaw from 24 to 27 April 1995. Totally 94 lectures have been presented. The actual state of art in Polish investigations have been shown in all branches of applied nuclear sciences. The plenary session devoted to general topics has began the symposium. Further conference has been divided into 18 subject sessions. There were: (1) radiation technologies in environment protection; (2) radiation technologies in materials engineering; (3) radiation preservation in food; (4) radiation techniques for medical use; (5) radiotracers in industrial investigations; (6) radiotracers in water and sewage management and leak control; (7) tracers in hydrology; (8) radiotracers in materials testing; (9) instruments for environment protection, (10) radiometric industrial gages; (11) diagnostic and testing instruments; (12) application of nuclear techniques in materials testing; (13) applications of nuclear techniques in geology and hydrogeology; (14) radioanalytical methods; (15) radiation detectors; (16) radiation measurements; (17) data processing from radiometric experiments; (18) accelerators, isotopes manufacturing, INIS.

  4. Ultrasound assisted extraction of food and natural products. Mechanisms, techniques, combinations, protocols and applications. A review.

    Science.gov (United States)

    Chemat, Farid; Rombaut, Natacha; Sicaire, Anne-Gaëlle; Meullemiestre, Alice; Fabiano-Tixier, Anne-Sylvie; Abert-Vian, Maryline

    2017-01-01

    This review presents a complete picture of current knowledge on ultrasound-assisted extraction (UAE) in food ingredients and products, nutraceutics, cosmetic, pharmaceutical and bioenergy applications. It provides the necessary theoretical background and some details about extraction by ultrasound, the techniques and their combinations, the mechanisms (fragmentation, erosion, capillarity, detexturation, and sonoporation), applications from laboratory to industry, security, and environmental impacts. In addition, the ultrasound extraction procedures and the important parameters influencing its performance are also included, together with the advantages and the drawbacks of each UAE techniques. Ultrasound-assisted extraction is a research topic, which affects several fields of modern plant-based chemistry. All the reported applications have shown that ultrasound-assisted extraction is a green and economically viable alternative to conventional techniques for food and natural products. The main benefits are decrease of extraction and processing time, the amount of energy and solvents used, unit operations, and CO 2 emissions. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Validation study of the modified injection technique for internal mammary sentinel lymph node biopsy in breast cancer

    Directory of Open Access Journals (Sweden)

    Cong BB

    2015-09-01

    Full Text Available Bin-Bin Cong,1,2,* Xiao-Shan Cao,1,2,* Peng-Fei Qiu,1 Yan-Bing Liu,1 Tong Zhao,1 Peng Chen,1 Chun-Jian Wang,1 Zhao-Peng Zhang,1 Xiao Sun,1 Yong-Sheng Wang1 1Breast Cancer Center, Shandong Cancer Hospital and Institute, 2School of Medicine and Life Sciences, Jinan University-Shandong Academy of Medical Sciences, Jinan, Shandong, People’s Republic of China *These authors contributed equally to this study Abstract: According to the hypothesis of internal mammary sentinel lymph node (IM-SLN lymphatic drainage pattern, a modified radiotracer injection technique (periareolar intraparenchyma, high volume, and ultrasonographic guidance was established. To verify the accuracy of the hypothesis and validate the modified radiotracer injection technique and to observe whether the lymphatic drainage of the whole breast parenchyma could reach to the same IM-SLN, different tracers were injected into different locations of the breast. The validation study results showed that the correlation and the agreement of the radiotracer and the fluorescence tracer are significant (case-base, rs =0.808, P<0.001; Kappa =0.79, P<0.001. It proved that the lymphatic drainage from different location of the breast (the primary tumor, the subareolar plexus reached the same IM-SLNs and the hypothesis of IM-SLN lymphatic drainage pattern (ie, IM-SLN receives lymphatic drainage from not only the primary tumor area, but also the entire breast parenchyma. In other words, it validated the accuracy of our modified radiotracer injection technique. Keywords: breast cancer, internal mammary, sentinel lymph node biopsy, visualization rate

  6. Microparticles containing guaraná extract obtained by spray-drying technique: development and characterization

    Directory of Open Access Journals (Sweden)

    Traudi Klein

    Full Text Available AbstractGuaraná (Paullinia cupana Kunth, Sapindaceae is well known for its dietary and pharmaceutical potential, and the semipurified extract of guaraná shows antidepressant and panicolytic effects. However, the low solubility, bioavailability and stability of the semipurified extract limit its use as a component of pharmaceutical agents. Delivery of the semipurified extract in a microparticle form could help to optimize its stability. In this study, microparticles containing semipurified extract of guaraná were obtained by the spray-drying technique, using a combination of maltodextrin and gum arabic. The raw materials and microparticles produced were characterized by particle size analysis, differential scanning calorimetry, thermogravimetric analysis, and scanning electron microscopy. The drug content and antioxidant capacity were also evaluated. In vitrodissolution tests using flow cell dissolution apparatus, were carried out to investigate the influence of formulation parameters on the release of semipurified extract of guaraná from the microparticles. The spray-drying technique and the processing conditions selected gave satisfactory encapsulation efficiency (80–110% and product yield (55–60%. The mean diameter of microparticles was around 4.5 µm. The DPPH radical scavenging capacity demonstrated that microparticles can protect the semipurified extract of guaraná from the effect of high temperatures during the process maintained the antioxidant capacity. Differential scanning calorimetry results indicated an interaction between semipurified extract of guaraná and gum arabic: maltodextrin in the microparticles, and thermogravimetric analysis indicate that the profile curves of the microparticles are similar to the adjuvants used in drying, probably due to the higher proportion of adjuvants compared to semipurified extract of guaraná. In vitro dissolution tests demonstrate that all formulations complete dissolution within 60 min

  7. Industrial applications of radioisotope techniques in Poland

    International Nuclear Information System (INIS)

    Michalik, J.St.

    1985-01-01

    A general review of applications of radioisotope techniques in the Polish industry for about 25 years is given. The radiotracer methods used in metallurgy, hydrometallurgy, glass industry, oil and petroleum industries, in material testing and in other industries are described. Neutron activation analysis methods as well as nuclear gauges for industry (thickness meters, density meters, conveyer belt weigher, acid concentration meters and others) are also presented. The economic advantages of industrial applications of radioisotope techniques are described too. 42 refs., 43 figs., 11 tabs. (author)

  8. Alternative oil extraction methods from Echium plantagineum L. seeds using advanced techniques and green solvents.

    Science.gov (United States)

    Castejón, Natalia; Luna, Pilar; Señoráns, Francisco J

    2018-04-01

    The edible oil processing industry involves large losses of organic solvent into the atmosphere and long extraction times. In this work, fast and environmentally friendly alternatives for the production of echium oil using green solvents are proposed. Advanced extraction techniques such as Pressurized Liquid Extraction (PLE), Microwave Assisted Extraction (MAE) and Ultrasound Assisted Extraction (UAE) were evaluated to efficiently extract omega-3 rich oil from Echium plantagineum seeds. Extractions were performed with ethyl acetate, ethanol, water and ethanol:water to develop a hexane-free processing method. Optimal PLE conditions with ethanol at 150 °C during 10 min produced a very similar oil yield (31.2%) to Soxhlet using hexane for 8 h (31.3%). UAE optimized method with ethanol at mild conditions (55 °C) produced a high oil yield (29.1%). Consequently, advanced extraction techniques showed good lipid yields and furthermore, the produced echium oil had the same omega-3 fatty acid composition than traditionally extracted oil. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Research on feature extraction techniques of Hainan Li brocade pattern

    Science.gov (United States)

    Zhou, Yuping; Chen, Fuqiang; Zhou, Yuhua

    2016-03-01

    Hainan Li brocade skills has been listed as world non-material cultural heritage preservation, therefore, the research on Hainan Li brocade patterns plays an important role in Li brocade culture inheritance. The meaning of Li brocade patterns was analyzed and the shape feature extraction techniques to original Li brocade patterns were advanced in this paper, based on the contour tracking algorithm. First, edge detection was made on the design patterns, and then the morphological closing operation was used to smooth the image, and finally contour tracking was used to extract the outer contours of Li brocade patterns. The extracted contour features were processed by means of morphology, and digital characteristics of contours are obtained by invariant moments. At last, different patterns of Li brocade design are briefly analyzed according to the digital characteristics. The results showed that the pattern extraction method to Li brocade pattern shapes is feasible and effective according to above method.

  10. Determination of the particle size distribution in a powder using radiotracers

    International Nuclear Information System (INIS)

    Revilla D, R.

    1974-01-01

    To determine experimentally the particle size distribution in a powder the meshed method is generally used. This method has the disadvantage that in the obtained distribution is not observed at detail the fine structure of such distribution. In this work, a method for obtaining the distribution of particle size using radiotracers is presented. In the obtained distribution by this method it is observed with more detail the fine structure of the distribution, comparing with the obtained results by the classical method of meshed. The radiotracer method has major resolution for the experimental determination mentioned. In the chapter 1, it is done a brief analysis about theoretical aspects related with the method. In the first part it is analysed the particle behavior (sedimenting) in a fluid. The second part treats the relating with the radioactivity of an activated material as well as its detection. In the chapter 2, a description of the method is done also the experimental problems to applying to the alumina crystals sample are discussed. In the chapter 3 the obtained results and the mistake calculations in such results are showed. Finally, in the chapter 4 the conclusions and recommendations are given which is possible to obtain better results and improve to those in this work were obtained. (Author)

  11. Application of radioisotopic techniques in elucidation of the effect of nutrition on reproductive functions

    International Nuclear Information System (INIS)

    Arora, S.P.; Kaur, Harjit

    1996-01-01

    Radiotracers are an important tool in investigation of several functions and anomalies which occur in the body as a result of disturbed metabolism. Radioisotopes techniques are useful in understanding the insight which pertains to the endocrine functions in livestock reproduction. In this paper various applications of radioisotopic techniques in livestock reproduction are described. 104 refs

  12. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    International Nuclear Information System (INIS)

    Sugiharto, S.; Kurniadi, R.; Abidin, Z.; Stegowski, Z.; Furman, L.

    2013-01-01

    Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT) having an inner diameter of 24 in (60,96 m). The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD) curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD) simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct. (author)

  13. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    Directory of Open Access Journals (Sweden)

    S. Sugiharto1

    2013-04-01

    Full Text Available Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT having an inner diameter of 24 in (60,96 m. The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct

  14. A dispersion model of transport media in radiotracer investigations on selected chemical installations

    International Nuclear Information System (INIS)

    Iller, E.

    1999-01-01

    Tracer investigations of media transport through chemical reactors play a significant role in the chemical technology. They provide the basis for the determination of some important process parameters, such as flow character of the transported medium, degree of utilisation of the reactor volume during chemical transitions of substrates or even indicate possible mechanisms of chemical reactions. Determination of the medium flow characteristics is closely connected with the mathematical description of the process - a mathematical model of transport. The method of assessment of radiotracers suitability for the investigation of distillation processes presented in this paper allows to determine, in a simple manner, the parameters of distillation characteristics of the radionuclides, the average distillation temperature, the range of distillation temperatures, a suitable radiochemical purity. These parameters precisely determine the behavior of tracers to be expected in a wide range of variable conditions of the distillation process. Applications of tracer tested in such a manner to the investigations of dynamics of media in the industrial rectification columns has resulted in obtaining a dependable evaluation of the performance of these columns in a wide range of changes of their operational parameters. Particular attention has been paid to dynamics of the liquid [phase on the column plate. A dispersion model of liquid flow with hold-up zones has been proposed for the description of the liquid phase transport in the plate - overall assembly.The model consists of a number of flow and stagnant zones, with mass transfer between them. Another example of practical application of results from radiotracer investigation is an analysis of of phase dynamics in the installations designed for the process of liquefaction of Polish coals by means of their catalytic hydrogenation. For the analysis of phase transport in a reaction vessel various mathematical models were applied with

  15. Various extraction and analytical techniques for isolation and identification of secondary metabolites from Nigella sativa seeds.

    Science.gov (United States)

    Liu, X; Abd El-Aty, A M; Shim, J-H

    2011-10-01

    Nigella sativa L. (black cumin), commonly known as black seed, is a member of the Ranunculaceae family. This seed is used as a natural remedy in many Middle Eastern and Far Eastern countries. Extracts prepared from N. sativa have, for centuries, been used for medical purposes. Thus far, the organic compounds in N. sativa, including alkaloids, steroids, carbohydrates, flavonoids, fatty acids, etc. have been fairly well characterized. Herein, we summarize some new extraction techniques, including microwave assisted extraction (MAE) and supercritical extraction techniques (SFE), in addition to the classical method of hydrodistillation (HD), which have been employed for isolation and various analytical techniques used for the identification of secondary metabolites in black seed. We believe that some compounds contained in N. sativa remain to be identified, and that high-throughput screening could help to identify new compounds. A study addressing environmentally-friendly techniques that have minimal or no environmental effects is currently underway in our laboratory.

  16. Investigation of liquid phase axial dispersion in Taylor bubble flow by radiotracer residence time distribution analysis

    Directory of Open Access Journals (Sweden)

    Jin J.H.

    2013-05-01

    Full Text Available A gas-liquid Taylor bubble flow occurs in small diameter channels in which gas bubbles are separated by slugs of pure liquid. This type of flow regime is well suited for solid catalyzed gas-liquid reactors in which the reaction efficiency is a strong function of axial dispersion in the regions of pure liquid. This paper presents an experimental study of liquid phase axial dispersion in a Taylor bubble flow developed in a horizontal tube using high speed photography and radiotracer residence time distribution (RTD analysis. A parametric dependence of axial dispersion on average volume fraction of gas phase was also investigated by varying the relative volumetric flow rates of the two phases. 137mBa produced from a 137Cs/137mBa radionuclide generator was used as radiotracer and measurements were made using the NaI(Tl scintillation detectors. Validation of 137mBa in the form of barium chloride as aqueous phase radiotracer was also carried out. Axial Dispersion Model (ADM was used to simulate the hydrodynamics of the system and the results of the experiment are presented. It was observed that the system is characterized by very high values of Peclet Number (Pe∼102 which reveals an approaching plug type flow. The experimental and model estimated values of mean residence times were observed in agreement with each other.

  17. FUEL CONTAMINATION IN A MARINE DIESEL ENGINE. A RADIOTRACER STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, B. E.

    1964-04-15

    A radiotracer method was applied to the problem of elucidating the mechanism of contamination of crankcase oil by fuel combustion products in a marine diesel engine. The method consisted of adding an oil soluble radioisotope to the fuel and tracing its route to the various lubricants used in the engine. It was found that of the total amount of combustion products and by-products which enter the crankcase oil, 65% enters by simple contamination via reintroduction of used cylinder lubricant and 35% by a condensation mechanism. (auth)

  18. Radiotracer aided optimization of batch mixing of solids

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Bergh, W.J.B. van den; Scarlett, B.

    1989-01-01

    A method for the determination of mixing times has been developed and tested in a model Nauta mixer filled with sand. 128 I-labelled sand particles were used as radiotracer and the progress of mixing was monitored with two radiation detectors located externally. The variance of the radiation intensity decreases with time until a constant value is reached indicating an equilibrium mixture of tracer and sand. The time necessary to achieve this condition (mixing time) appears to be dependent on the rotational speed of the hopper as well as the screw of the mixer. Optimal mixing performance (shortest mixing time) corresponds to the maximal rotational speeds of both rotating parts of the mixer. (author)

  19. Nuclear techniques in coal and chemical industries

    International Nuclear Information System (INIS)

    Elbern, A.W.; Leal, C.A.

    1980-01-01

    The use of nuclear techniques for the determination of important parameters in industrial installations is exemplified; advantages of these techniques over other methods conventionally used are pointed out. The use of radiotracers in the study of physical and chemical phenomena occurring in the chemical industry is discussed. It is also shown that, using certain radioisotopes, it is possible to construct devices which enable, for example, the determination of the ash content in coal samples. These devices are economical and easy to be installed for the on-line control during coal transportation. (C.L.B.) [pt

  20. Comparison of various techniques for the extraction of umbelliferone and herniarin in Matricaria chamomilla processing fractions.

    Science.gov (United States)

    Molnar, Maja; Mendešević, Nikolina; Šubarić, Drago; Banjari, Ines; Jokić, Stela

    2017-08-05

    Chamomile, a well-known medicinal plant, is a rich source of bioactive compounds, among which two coumarin derivatives, umbelliferone and herniarin, are often found in its extracts. Chamomile extracts have found a different uses in cosmetic industry, as well as umbelliferone itself, which is, due to its strong absorption of UV light, usually added to sunscreens, while herniarin (7-methoxycoumarin) is also known for its biological activity. Therefore, chamomile extracts with certain herniarin and umbelliferone content could be of interest for application in pharmaceutical and cosmetic products. The aim of this study was to compare the extracts of different chamomile fractions (unprocessed chamomile flowers first class, processed chamomile flowers first class, pulvis and processing waste) and to identify the best material and method of extraction to obtain herniarin and umbelliferone. Various extraction techniques such as soxhlet, hydrodistillation, maceration and supercritical CO 2 extraction were used in this study. Umbelliferone and herniarin content was determined by high performance liquid chromatography (HPLC). The highest yield of umbelliferone (11.80 mg/100 g) and herniarin (82.79 mg/100 g) were obtained from chamomile processing waste using maceration technique with 50% aqueous ethanol solution and this extract has also proven to possess antioxidant activity (61.5% DPPH scavenging activity). This study shows a possibility of potential utilization of waste from chamomile processing applying different extraction techniques.

  1. [Comparison of techniques for coliform bacteria extraction from sediment of Xochimilco Lake, Mexico].

    Science.gov (United States)

    Fernández-Rendón, Carlos L; Barrera-Escorcia, Guadalupe

    2013-01-01

    The need to separate bacteria from sediment in order to appropriately count them has led to test the efficacy of different techniques. In this research, traditional techniques such as manual shaking, homogenization, ultrasonication, and surfactant are compared. Moreover, the possibility of using a set of enzymes (pancreatine) and an antibiotic (ampicillin) for sediment coliform extraction is proposed. Samples were obtained from Xochimilco Lake in Mexico City. The most probable number of coliform bacteria was determined after applying the appropriate separation procedure. Most of the techniques tested led to numbers similar to those of the control (manual shaking). Only with the use of ampicillin, a greater total coliform concentration was observed (Mann-Whitney, z = 2.09; p = 0.03). It is possible to propose the use of ampicillin as a technique for total coliform extraction; however, it is necessary to consider sensitivity of bacteria to the antibiotic.

  2. A technique system for the measurement, reconstruction and character extraction of rice plant architecture.

    Directory of Open Access Journals (Sweden)

    Xumeng Li

    Full Text Available This study developed a technique system for the measurement, reconstruction, and trait extraction of rice canopy architectures, which have challenged functional-structural plant modeling for decades and have become the foundation of the design of ideo-plant architectures. The system uses the location-separation-measurement method (LSMM for the collection of data on the canopy architecture and the analytic geometry method for the reconstruction and visualization of the three-dimensional (3D digital architecture of the rice plant. It also uses the virtual clipping method for extracting the key traits of the canopy architecture such as the leaf area, inclination, and azimuth distribution in spatial coordinates. To establish the technique system, we developed (i simple tools to measure the spatial position of the stem axis and azimuth of the leaf midrib and to capture images of tillers and leaves; (ii computer software programs for extracting data on stem diameter, leaf nodes, and leaf midrib curves from the tiller images and data on leaf length, width, and shape from the leaf images; (iii a database of digital architectures that stores the measured data and facilitates the reconstruction of the 3D visual architecture and the extraction of architectural traits; and (iv computation algorithms for virtual clipping to stratify the rice canopy, to extend the stratified surface from the horizontal plane to a general curved surface (including a cylindrical surface, and to implement in silico. Each component of the technique system was quantitatively validated and visually compared to images, and the sensitivity of the virtual clipping algorithms was analyzed. This technique is inexpensive and accurate and provides high throughput for the measurement, reconstruction, and trait extraction of rice canopy architectures. The technique provides a more practical method of data collection to serve functional-structural plant models of rice and for the

  3. Applications of Beta Particle Detection for Synthesis and Usage of Radiotracers Developed for Positron Emission Tomography

    Science.gov (United States)

    Dooraghi, Alex Abreu

    Positron Emission Tomography (PET) is a noninvasive molecular imaging tool that requires the use of a radioactive compound or radiotracer which targets a molecular pathway of interest. We have developed and employed three beta particle radiation detection systems to advance PET. Specifically, the goals of these systems are to: 1. Automate dispensing of solutions containing a positron emitting isotope. 2. Monitor radioactivity on-chip during synthesis of a positron emitting radiotracer. 3. Assay cellular uptake on-chip of a positron emitting radiotracer. Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing an optimum environment for radiation workers, but also to ensure a quantitatively accurate workflow. For the first project, we describe the development and performance of a system for automated radioactivity distribution of beta particle emitting radioisotopes such as fluorine-18 (F-18). Key to the system is a radiation detector in-line with a peristaltic pump. The system demonstrates volume accuracy within 5 % for volumes of 20 muL or greater. When considering volumes of 20 muL or greater, delivered radioactivity is in agreement with the requested radioactivity as measured with the dose calibrator. The integration of the detector and pump leads to a flexible system that can accurately dispense solutions containing F-18 in radioactivity concentrations directly produced from a cyclotron (~ 0.1-1 mCi/muL), to low activity concentrations intended for preclinical mouse scans (~ 1-10 muCi/muL), and anywhere in between. Electrowetting on dielectric (EWOD) is an attractive microfluidic platform for batch synthesis of PET radiotracers. Visualization of radioisotopes on-chip is critical for synthesis optimization and technological development. For the second project, we describe the development and performance of a Cerenkov/real-time imaging system for PET radiotracer synthesis on EWOD. We also investigate

  4. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  5. Simpler and More Accurate: Weighing the Mercury in Electrolytic Cells by Radiotracer Dilution Method

    Directory of Open Access Journals (Sweden)

    Sugiharto

    2010-08-01

    Full Text Available Weight of mercury in electrolytic cell of soda industry is usually measured gravimetrically, which is typical labor work in character. Error sources of the gravimetric method might have come from the fact that some mercury’s are usually trapped in the cell due to complicated structure of electrolytic cell. This cause unknown errors. In addition, formation of amalgam at the cathode may cause a further uncertainty in the measurement. Total error from gravimetric method is 4% on average. Radiotracer dilution method provides advantages either for simplification of procedure and reduction of measurement error. In this experiment radioisotope mercury 203Hg, which was prepared in nuclear reactor was used to examine 13 of 14 electrolytic cells of soda plant. Each electrolytic cell was designed containing approximately 700 kg inactive mercury. Before injection, the radioisotope mercury was mixed with non radioisotope mercury in a bath to obtain a suitable injection aliquots and standard references. Calibration curve, which was derived from two stage dilution processes taken from standard references, was used to examine degree of mixing between radioisotope and non radioisotope mercury and it was also used in weight calculation of non radioisotope mercury in electrolytic cell. Injection was carried out simply by pouring the injection aliquots into the flowing mercury at the inlet side of the cell. Mercury samples from the cells were extracted at regular time intervals and filled into vials for counting. This was done for the primary conformation of the completeness of mixing of the tracer with the non radioisotope mercury in each cell. When complete mixing is achieved, the unknown quantity of mercury in each cell was calculated based on mass balance principle. From the calculation the weight of mercury in each electrolytic cell was not the same and maximum error of measurement obtained from this method is 2.48 %. Compared to gravimetrically error

  6. Simpler and More Accurate: Weighing the Mercury in Electrolytic Cells by Radiotracer Dilution Method

    International Nuclear Information System (INIS)

    Sugiharto; Santoso, S.B.; Santoso, G.B.

    2010-01-01

    Weight of mercury in electrolytic cell of soda industry is usually measured gravimetrically, which is typical labor work in character. Error sources of the gravimetric method might have come from the fact that some mercury's are usually trapped in the cell due to complicated structure of electrolytic cell. This cause unknown errors. In addition, formation of amalgam at the cathode may cause a further uncertainty in the measurement. Total error from gravimetric method is 4% on average. Radiotracer dilution method provides advantages either for simplification of procedure and reduction of measurement error. In this experiment radioisotope mercury 203 Hg, which was prepared in nuclear reactor was used to examine 13 of 14 electrolytic cells of soda plant. Each electrolytic cell was designed containing approximately 700 kg inactive mercury. Before injection, the radioisotope mercury was mixed with non radioisotope mercury in a bath to obtain a suitable injection aliquots and standard references. Calibration curve, which was derived from two stage dilution processes taken from standard references, was used to examine degree of mixing between radioisotope and non radioisotope mercury and it was also used in weight calculation of non radioisotope mercury in electrolytic cell. Injection was carried out simply by pouring the injection aliquots into the flowing mercury at the inlet side of the cell. Mercury samples from the cells were extracted at regular time intervals and filled into vials for counting. This was done for the primary conformation of the completeness of mixing of the tracer with the non radioisotope mercury in each cell. When complete mixing is achieved, the unknown quantity of mercury in each cell was calculated based on mass balance principle. From the calculation the weight of mercury in each electrolytic cell was not the same and maximum error of measurement obtained from this method is 2.48 %. Compared to gravimetrically error mentioned above, it was

  7. Imaging in hearing using radiotracers

    Directory of Open Access Journals (Sweden)

    Berding Georg

    2017-09-01

    Full Text Available Radiotracers offer unique options for brain imaging of functional and molecular processes related to hearing. Such imaging can be applied in a broad spectrum of situations from preclinical research to clinical patient care. Functional imaging to assess activation in brain regions and networks involved in auditory processing uses markers of blood flow or energy-metabolism in well-defined conditions with and without auditory stimulation. Molecular markers can be used in hearing research for example to study changes in inhibitory neurotransmission systems related to hearing loss. For imaging either positron emission tomography (PET or single-photon emission computed tomography (SPECT are employed. Data analysis can encompasses voxel-wise statistical analysis of activation and calculation of quantitative parameters like receptor binding-potentials based on bio-kinetic modeling. Functional imaging has been frequently used in the context of auditory implantation. Before implantation it aims to assess intactness of the central auditory pathway and prognosis. After implantation it is used to improve understanding of the outcome with respect to auditory function and finally speech understanding, e.g. by measuring correlates of central auditory processing and neuroplasticity.

  8. Radiotracer experiments on the uptake of radionuclides by mushrooms and vegetables

    International Nuclear Information System (INIS)

    Ban-Nai, Tadaaki; Muramatsu, Yasuyuki; Yoshida, Satoshi; Yanagisawa, Kei

    1996-01-01

    Radiotracer experiments were performed to study radionuclide uptake by mushrooms and plants. Four mushroom species, Hebeloma vinosophyllum, Flammulina velutipes, Agrocybe cylindracea and Coprinus phlyctidosporus were cultivated in a flask containing medium with the radiotracers 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn. Mushrooms tended to accumulate Cs, Mn and Zn. The concentration ratio of Cs between mushroom and medium ranged from 2.6 to 21. The highest was observed in H. vinospohyllum. The concentration ratio of Mn was about 10, while the ratio of Zn ranged from 15 to 30. No noticeable accumulations were found for Sr or Co. Transfer factors (TFs) of radionuclides from soil to leaf vegetables (cabbage, Chinese cabbage, komatsuna, spinach and lettuce) were also studied using Andosol (a representative Japanese soil). The TFs of 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn for edible parts of these vegetables were (mean value) 0.11, 0.24, 0.61, 0.05 and 0.52, respectively. The TFs of Mn, Co and Zn for spinach were higher than those for the other vegetables. The distributions of Cs in different organs of the leaf vegetables were rather uniform. The TFs of Sr and Mn were higher for older (outer) leaves than younger (inner) ones. In contrast to Sr and Mn, TFs of Zn for younger leaves were higher than those for older ones

  9. Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques.

    Science.gov (United States)

    Mamoun, John

    2017-06-01

    In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

  10. Extraction of three bioactive diterpenoids from Andrographis paniculata: effect of the extraction techniques on extract composition and quantification of three andrographolides using high-performance liquid chromatography.

    Science.gov (United States)

    Kumar, Satyanshu; Dhanani, Tushar; Shah, Sonal

    2014-10-01

    Andrographis paniculata (Burm.f.) wall.ex Nees (Acanthaceae) or Kalmegh is an important medicinal plant finding uses in many Ayurvedic formulations. Diterpenoid compounds andrographolides (APs) are the main bioactive phytochemicals present in leaves and herbage of A. paniculata. The efficiency of supercritical fluid extraction (SFE) using carbon dioxide was compared with the solid-liquid extraction techniques such as solvent extraction, ultrasound-assisted solvent extraction and microwave-assisted solvent extraction with methanol, water and methanol-water as solvents. Also a rapid and validated reverse-phase high-performance liquid chromatography-diode array detection method was developed for the simultaneous determination of the three biologically active compounds, AP, neoandrographolide and andrograpanin, in the extracts of A. paniculata. Under the best SFE conditions tested for diterpenoids, which involved extraction at 60°C and 100 bar, the extractive efficiencies were 132 and 22 µg/g for AP and neoandrographolide, respectively. The modifier percentage significantly affected the extraction efficiency. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Effects of flow changes on radiotracer binding: Simultaneous measurement of neuroreceptor binding and cerebral blood flow modulation.

    Science.gov (United States)

    Sander, Christin Y; Mandeville, Joseph B; Wey, Hsiao-Ying; Catana, Ciprian; Hooker, Jacob M; Rosen, Bruce R

    2017-01-01

    The potential effects of changes in blood flow on the delivery and washout of radiotracers has been an ongoing question in PET bolus injection studies. This study provides practical insight into this topic by experimentally measuring cerebral blood flow (CBF) and neuroreceptor binding using simultaneous PET/MRI. Hypercapnic challenges (7% CO 2 ) were administered to non-human primates in order to induce controlled increases in CBF, measured with pseudo-continuous arterial spin labeling. Simultaneously, dopamine D 2 /D 3 receptor binding of [ 11 C]raclopride or [ 18 F]fallypride was monitored with dynamic PET. Experiments showed that neither time activity curves nor quantification of binding through binding potentials ( BP ND ) were measurably affected by CBF increases, which were larger than two-fold. Simulations of experimental procedures showed that even large changes in CBF should have little effect on the time activity curves of radiotracers, given a set of realistic assumptions. The proposed method can be applied to experimentally assess the flow sensitivity of other radiotracers. Results demonstrate that CBF changes, which often occur due to behavioral tasks or pharmacological challenges, do not affect PET [ 11 C]raclopride or [ 18 F]fallypride binding studies and their quantification. The results from this study suggest flow effects may have limited impact on many PET neuroreceptor tracers with similar properties.

  12. Nuclear and radiation techniques - state of art and development trends

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1995-01-01

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig

  13. Complex investigation of extraction techniques applied for cyclitols and sugars isolation from different species of Solidago genus.

    Science.gov (United States)

    Ratiu, Ileana-Andreea; Al-Suod, Hossam; Ligor, Magdalena; Ligor, Tomasz; Railean-Plugaru, Viorica; Buszewski, Bogusław

    2018-03-15

    Cyclitols are phytochemicals naturally occurring in plant material, which attracted an increasing interest due to multiple medicinal attributes, among which the most important are the antidiabetic, antioxidant, and anticancer properties. Due to their valuable properties, sugars are used in the food industry as sweeteners, preservatives, texture modifiers, fermentation substrates, and flavoring and coloring agents. In this study, we report for the first time the quantitative analysis of sugars and cyclitols isolated from Solidago virgaurea L., which was used for the selection of the optimal solvent and extraction technique that can provide the best possible yield. Moreover, the quantities of sugars and cyclitols extracted from two other species, Solidago canadensis and Solidago gigantea, were investigated using the best extraction method and the most appropriate solvent. Comparative analysis of natural plant extracts obtained using five different techniques-maceration, Soxhlet extraction, pressurized liquid extraction, ultrasound-assisted extraction, and supercritical fluid extraction-was performed in order to decide the most suitable, efficient, and economically convenient extraction method. Three different solvents were used. Analysis of samples has been performed by solid-phase extraction for purification and pre-concentration, followed by derivation and GC-MS analysis. Highest efficiency for the total amount of obtained compounds has been reached by PLE, when water was used as a solvent. d-pinitol amount was almost similar for every solvent and for all the extraction techniques involved. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Evaluation of radiotracers for the detection of atherosclerotic vulnerable plaque and myocardial angiogenesis

    International Nuclear Information System (INIS)

    Dimastromatteo, Julien

    2010-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide. Coronary events are mainly caused by coronary plaque rupture or erosion. However, at present, there is no noninvasive tool available for the detection of vulnerable plaques. The first part of thesis is about evaluation of new radiotracers for the detection of atherosclerotic vulnerable plaques. 99m Tc-B2702p, 20 derivatives, 99m Tc-VP and 99m Tc-VINP28 were evaluated in an experimental model of atherosclerosis (ApoE-/- mice with left carotid artery ligation). 99m Tc- B2702p1 is a potentially useful radiotracer for the in vivo molecular imaging of VCAM-1 expression in atherosclerotic plaques. Myocardial angiogenesis is an important post infarction phenomenon. Angiogenic therapy improves experimentally cardiac parameters. However, clinical trials using the same therapy are more controversial. At present, clinical imaging tools don't allow us to assess angiogenesis therapy. The second part of thesis is about validation of 99m Tc-RAFT-RGD in the detection of myocardial angiogenesis. 99m Tc-RAFT-RGD allow us to perform noninvasive molecular imaging of myocardial angiogenesis in an experimental model. (author)

  15. Application of Solvent-In-Pulp Technique for Uranium Extraction from Mineralization Granite

    International Nuclear Information System (INIS)

    Ali, M.M.; Hussein, A.E.M.; Youseif, W.M.; El Didamony, A.M.

    2017-01-01

    Investigations on uranium extraction from a representative mineralized granite sample (Gattar granite GII) by solvent-in-pulp (SIP) technique were carried out in the present study. For this purpose, the solvent (tri-butyl amine) (TBA) was mixed with the leaching slurry without prior filtration. The influence of various factors affecting the SIP process, such as contact time, solvent concentration, dilution factor, type of surfactant, surfactant/solid ratio were studied. About 91% uranium extraction efficiency was attained by the application of the chosen extraction SIP conditions. Also, about 96% of the loaded uranium could be stripped by using sulfuric acid as an effective stripping agent

  16. Characterization of a radiotracer-based 3-hydroxy-1-methyl peridine by its analogue Rhene

    International Nuclear Information System (INIS)

    Zitouni, Zeineb

    2010-01-01

    Since the discovery of artificial radioactivity in 1934, nuclear doctors have a variety of radioactive isotopes as indicators and markers. With these radioactive isotopes, it is possible to trace an atom or a chemical species without disrupting the physical behavior, chemical or biological. The branch of medicine and medical specialty now devoted to the use of radioactive elements for examination or treatment of patients, particularly the brain. Having a close relationship with radiobiology, radiation protection and Radiopharmacy, Nuclear Medicine Specialist is empowered to handle potentially dangerous isotope, observing precautions and regulations designed to reduce their risks. These radionuclides are used for exploration of cell kinetics, pharmacokinetics or for scans. Activities under this project led to the synthesis of N-methylferrocene, its characterization and its labeling with technetium 99 m. For the characterization of the radiotracer synthesized, we used to study the properties of complex similar models, labeled with rhenium. To verify and confirm this work, we propose the following perspectives: - Confirm the structure of N-methyl rhenium by nuclear magnetic resonance and single crystal X ray crystallography. - Develop and characterize new radiotracers brain.

  17. A novel technique of percutaneous stone extraction in choledocholithiasis after cholecystostomy.

    Science.gov (United States)

    Lim, Kyoung Hoon; Kim, Yong Joo

    2013-05-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous common bile duct stone extraction via cystic duct after percutaneous cholecystostomy. Twenty-five consecutive patients with choledocholithiasis underwent percutaneous stone extraction under conscious sedation. The stones were extracted through the 12-Fr sheath using Wittich nitinol stone basket under fluoroscopic guidance via cystic duct after percutaneous trnas-hepatic cholecystostomy. Common bile duct stones were successfully removed in 22 of the 25 patients (88%) by this new technique. The causes of failure in three patients were bile leakage, hematoma of the gallbladder and failure of cystic duct cannulation. Cystic duct injury during this procedure did not occur and there was no post-procedure mortality. The mean period of indwelling catheter was 8.7±4.6 days and the mean duration of hospitalization was 13.4±5.9 days. Percutaneous commmon bile duct stone extraction via the cystic duct through percutaneous cholecystostomy route is effective and feasible for treating choledocholithiasis.

  18. Radiation technologies and techniques friendly for environment and men

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Walis, L.

    1995-01-01

    Development of radiation technologies and techniques in Poland has been shown. Especially thermoshrinkable olefins with shape memory, fast thermistors and radiation sterilization have been presented. Also the radiometric gages produced in the Institute of Nuclear Chemistry and Technology, Warsaw for air monitoring have been described. A broad group of radiotracer techniques being used for environmental study have been presented as well. Radiation technologies with electron beam use for flue gas purification, sewage sludge hygienization and food processing have been shown and their development has been discussed

  19. Radiotracer laboratory for agricultural research at the Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Nashriyah Mat; Misman Sumin; Maizatul Akmam Mhd Nasir

    2007-01-01

    Radiotracer Laboratory for agricultural research at the Malaysian Nuclear Agency was established since 1990. It accommodates three laboratories, three chemical temporary storage compartments plus one compartment for storage of pressurized gas. This facility is situated in ground floor of Block 44, Agrotechnology and Biosciences Division, Dengkil Complex. Currently it houses a liquid scintillation counter, sample oxidizer, gas liquid chromatography, high performance liquid chromatography and auxiliary equipments. A road map for this laboratory will be discussed in relation with present scenario i.e. R and D service, training and consultancy provided by this laboratory; and future requirements and direction. (Author)

  20. Radiotracer investigation of the cold-vapour atomic absorption method of analysis for trace mercury

    International Nuclear Information System (INIS)

    Stuart, D.C.

    1978-01-01

    Because of certain problems found in application of the atomic absorption method for trace analysis of mercury, a careful check of the procedures used was undertaken, with radiotracer mercury to facilitate the investigation. The results obtained, in conjunction with those of sample ashing procedures, indicate that the method is less straightforward than its simplicity suggests. (Auth.)

  1. Development of [11C]-α-aminoisobutyric acid and [18F]-haloperidol as substrate-specific radiotracers

    International Nuclear Information System (INIS)

    Zanzonico, P.B.

    1982-01-01

    In light of the emergence of positron emission tomography (PET), two new substrate-specific radiotracers have been synthesized and evaluated as potential agents for the study of specific physiological processes: [1- 11 C]-α-aminoisobutyric acid ([1- 11 C]-AIB), a transport system-specific radiotracer for tumor localization and for the assessment of amino acid transport in vivo; and [ 18 F]-haloperidoll, a receptor-binding radiotracer for the assessment of brain dopamine receptors in vivo. AIB, a non-metabolized amino acid, accumulates in cells, particularly malignant cells, via the A type, or ''alanine-preferring'', amino acid transport system [1- 11 C]-AIB in normal and in treated and untreated tumor-bearing rats, in tumor-bearing dogs, and in a tumor-bearing patient indicate rapid blood clearance and, concomitantly, rapid tissue localization, with slow net redistribution. Generally, there was selective localization in the kidney, in the liver, and in the pancreas, as well as in various tumors. The canine tumors and the human tumor were well visualized by external scintigraphy, especially when utilizing PET. [ 18 F]-Haloperidol, a dopamine receptor-binding neuroleptic of the butyrophenone series widely used in the management of schizophrenia was prepared via the Balz-Schiemann reaction. As the haloperdol dose administered to mice was increased from 0.01 to 1000 μg/kg, the relative concentration (μCi found per gm tisue sample/μCi injected per gm body mass) of [ 18 F]-haloperidol at 1 hr decreased from 30 to 1.0 in the striatum and from 8.0 to 1.0 in the cerebellum. The decrease in striatum radioactivity reflects competition between labeled and unlabeled haloperidol for dopamine receptors

  2. Comparison of two peptide radiotracers for prostate carcinoma targeting

    Directory of Open Access Journals (Sweden)

    Bluma Linkowski Faintuch

    2012-01-01

    Full Text Available OBJECTIVES: Scintigraphy is generally not the first choice treatment for prostate cancer, although successful studies using bombesin analog radiopeptides have been performed. Recently, a novel peptide obtained using a phage display library demonstrated an affinity for prostate tumor cells. The aim of this study was to compare the use of a bombesin analog to that of a phage display library peptide (DUP-1 radiolabeled with technetium-99m for the treatment of prostate carcinoma. The peptides were first conjugated to S-acetyl-MAG3 with a 6-carbon spacer, namely aminohexanoic acid. METHODS: The technetium-99m labeling required a sodium tartrate buffer. Radiochemical evaluation was performed using ITLC and was confirmed by high-performance liquid chromatography. The coefficient partition was determined, and in vitro studies were performed using human prostate tumor cells. Biodistribution was evaluated in healthy animals at various time points and also in mice bearing tumors. RESULTS: The radiochemical purity of both radiotracers was greater than 95%. The DUP-1 tracer was more hydrophilic (log P = -2.41 than the bombesin tracer (log P = -0.39. The biodistribution evaluation confirmed this hydrophilicity by revealing the greater kidney uptake of DUP-1. The bombesin concentration in the pancreas was greater than that of DUP-1 due to specific gastrin-releasing peptide receptors. Bombesin internalization occurred for 78.32% of the total binding in tumor cells. The DUP-1 tracer showed very low binding to tumor cells during the in vitro evaluation, although tumor uptake for both tracers was similar. The tumors were primarily blocked by DUP1 and the bombesin radiotracer primarily targeted the pancreas. CONCLUSION: Further studies with the radiolabeled DUP-1 peptide are recommended. With further structural changes, this molecule could become an efficient alternative tracer for prostate tumor diagnosis.

  3. Oil flow rate measurements using 198Au and total count technique

    International Nuclear Information System (INIS)

    Goncalves, Eduardo R.; Crispim, Verginia R.

    2013-01-01

    In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and 1/2, 3/4, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198 Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2'x 2', with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud. (author)

  4. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  5. Two simple techniques for the safe Sarcoptes collection and individual mite DNA extraction.

    Science.gov (United States)

    Soglia, Dominga; Rambozzi, Luisa; Maione, Sandra; Spalenza, Veronica; Sartore, Stefano; Alasaad, Samer; Sacchi, Paola; Rossi, Luca

    2009-10-01

    Availability of mites is a recognized limiting factor of biological and genetic investigations of the genus Sarcoptes. Current methods of deoxyribonucleic acid (DNA) extraction from individual mites also need substantial improvement in efficiency and operator friendliness. We have first developed a technique for efficient and safe extraction of living mites from scabietic skin samples (crusts or deep skin scrapings). Its core device is a large plastic syringe connected with a 1.5-ml Eppendorf tube. The source material is introduced in the syringe and the device in a shoe box with the tip half of the tube emerging. Mites migrate towards a heat source during a minimum of 36 h. Then, the tube is detached and the mites utilized without risks for the operators. A second technique allows operator-friendly manipulation of individual mites for DNA extraction. Fixed mites are isolated by adhesion to a small strip of polyvinyl chloride (PVC) adhesive tape operated with tweezers. Then, mite and strip are plunged in the lyses buffer and the sample twice submitted to thermal shock for disruption of the chitinous exoskeleton. Data show that the tape does not interfere with successive DNA extraction with a commercial kit. The corresponding protocol, that we briefly name "PVC adhesive tape + thermal shock + kit DNA extraction," compares favorably with the available ones.

  6. A Novel Technique for Shape Feature Extraction Using Content Based Image Retrieval

    Directory of Open Access Journals (Sweden)

    Dhanoa Jaspreet Singh

    2016-01-01

    Full Text Available With the advent of technology and multimedia information, digital images are increasing very quickly. Various techniques are being developed to retrieve/search digital information or data contained in the image. Traditional Text Based Image Retrieval System is not plentiful. Since it is time consuming as it require manual image annotation. Also, the image annotation differs with different peoples. An alternate to this is Content Based Image Retrieval (CBIR system. It retrieves/search for image using its contents rather the text, keywords etc. A lot of exploration has been compassed in the range of Content Based Image Retrieval (CBIR with various feature extraction techniques. Shape is a significant image feature as it reflects the human perception. Moreover, Shape is quite simple to use by the user to define object in an image as compared to other features such as Color, texture etc. Over and above, if applied alone, no descriptor will give fruitful results. Further, by combining it with an improved classifier, one can use the positive features of both the descriptor and classifier. So, a tryout will be made to establish an algorithm for accurate feature (Shape extraction in Content Based Image Retrieval (CBIR. The main objectives of this project are: (a To propose an algorithm for shape feature extraction using CBIR, (b To evaluate the performance of proposed algorithm and (c To compare the proposed algorithm with state of art techniques.

  7. Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [18F]MNI-698

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Caillé, Fabien; Barret, Olivier; Papin, Caroline; Lee, Hsiaoju; Morley, Thomas J.; Fowles, Krista; Holden, Daniel; Seibyl, John P.; Alagille, David; Tamagnan, Gilles D.

    2014-01-01

    Introduction: A new radiotracer for imaging the serotonin 4 receptors (5-HT 4 ) in brain, [ 18 F]MNI-698, was recently developed by our group. Evaluation in nonhuman primates indicates the novel radiotracer holds promise as an imaging agent of 5-HT 4 in brain. This paper aims to describe the whole-body biodistribution and dosimetry estimates of [ 18 F]MNI-698. Methods: Whole-body positron emission tomography (PET) images were acquired over 240 minutes after intravenous bolus injection of [ 18 F]MNI-698 in adult rhesus monkeys. Different models were investigated for quantification of radiation absorbed and effective doses using OLINDA/EXM 1.0 software. Results: The radiotracer main elimination route was found to be urinary and the critical organ was the urinary bladder. Modeling of the urinary bladder voiding interval had a considerable effect on the estimated effective dose. Normalization of rhesus monkeys’ organs and whole-body masses to human equivalent reduced the calculated dosimetry values. The effective dose ranged between 0.017 and 0.027 mSv/MBq. Conclusion: The dosimetry estimates, obtained when normalizing organ and whole-body weights and applying the urinary bladder model, indicate that the radiation doses from [ 18 F]MNI-698 comply with limits and guidelines recommended by key regulatory authorities that govern the translation of radiotracers to human clinical trials. The timing of urinary bladder emptying should be considered when designing future clinical protocols with [ 18 F]MNI-698, in order to minimize the subject absorbed doses

  8. Non-destructive investigation of technical plants and processes and natural processes by short-lived radionuclides (radiotracer)

    International Nuclear Information System (INIS)

    Jentsch, Thorsten; Zeuner, Albert

    2009-01-01

    Short lived open radionuclides are very suitable to investigate transport and mixing processes. They do not pollute the product. After decay of the radionuclide, the product can be used without any restrictions. Examples are showed for technical processes investigation by aid of radiotracer. (orig.)

  9. Determination of stability constants of lanthanide nitrate complex formation using a solvent extraction technique

    International Nuclear Information System (INIS)

    Andersson, S.; Ekberg, C.; Liljenzin, J.O.; Nilsson, M.; Skarnemark, G.; Eberhardt, K.

    2006-01-01

    For lanthanides and actinides, nitrate complex formation is an important factor with respect to the reprocessing of nuclear fuels and in studies that treat partitioning and transmutation/conditioning. Different techniques, including microcalorimetry, various kinds of spectroscopy, ion-exchange and solvent extraction, can be used to determine stability constants of nitrate complex formation. However, it is uncommon that all lanthanides are studied at the same time, using the same experimental conditions and technique. The strengths of the complexes are different for lanthanides and actinides, a feature that may assist in the separation of the two groups. This paper deals with nitrate complex formation of lanthanides using a solvent extraction technique. Trace amounts of radioactive isotopes of lanthanides were produced at the TRIGA Mainz research reactor and at the Institutt for Energiteknikk in Kjeller, Norway (JEEP II reactor). The extraction of lanthanide ions into an organic phase consisting of 2, 6-bis-(benzoxazolyl)-4-dodecyloxylpyridine, 2-bromodecanoic acid and tert-butyl benzene as a function of nitrate ion concentration in the aqueous phase was studied in order to estimate the stability constants of nitrate complex formation. When the nitrate ion concentration is increased in the aqueous phase, the nitrate complex formation starts to compete with the extraction of metal ions. Thus the stability constants of nitrate complex formation can be estimated by measuring the decrease in extraction and successive fitting of an appropriate model. Extraction curves for La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Dy, Ho and Er were obtained and stability constants for their nitrate complex formation were estimated. Tb, Tm, Yb and Lu were also investigated, but no stability constants could be determined. The distribution ratios for the metal ions at low nitrate ion concentration were obtained at the same time, showing the effect of lanthanide contraction resulting in decreasing

  10. Comparison of various techniques for the extraction and determination of antioxidants in plants.

    Science.gov (United States)

    Bajerová, Petra; Adam, Martin; Bajer, Tomáš; Ventura, Karel

    2014-04-01

    The following extraction techniques have been used for extracting antioxidants (apigenin, coumarin, esculetin, umbelliferone, bergapten, quercetin, rutin, scopoletin and xanthotoxin) from plant material: supercritical fluid extraction, pressurized liquid extraction, extraction by means of Soxhlet apparatus, ultrasonic extraction in ultrasonic bath, and by means of ultrasonic probe. The analytical method based on HPLC-UV detection for the determination of selected antioxidants was developed. For all extracts the antioxidant capacity based on the reduction of free 2,2-diphenyl-1-picrylhydrazyl radical was also determined. Comparing all results the ultrasonic probe method using 0.75 g of sample extracted by 50 mL of acetonitrile in water (30%, v/v) for 25 min at room temperature and with amplitude at 60% (equal to 90 W) without pulsation was evaluated as the best tool. The most significant indicator demonstrating this statement is the antioxidant capacity expressed as gallic acid equivalent where the ultrasonic probe method showed the best results in 10 of 16 samples. Also the operability of ultrasonic probe extraction method compared to other tested methods is more favorable. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Mercury methylation and reduction potentials in marine water: An improved methodology using {sup 197}Hg radiotracer

    Energy Technology Data Exchange (ETDEWEB)

    Koron, Neza [National Institute of Biology, Marine Biology Station, Fornace 41, 6330 Piran (Slovenia); Bratkic, Arne [Department of Environmental Sciences, ' Jozef Stefan' Institute, Jamova 39, 1000 Ljubljana (Slovenia); Ribeiro Guevara, Sergio, E-mail: ribeiro@cab.cnea.gov.ar [Laboratorio de Analisis por Activacion Neutronica, Centro Atomico Bariloche, Av. Bustillo km 9.5, 8400 Bariloche (Argentina); Vahcic, Mitja; Horvat, Milena [Department of Environmental Sciences, ' Jozef Stefan' Institute, Jamova 39, 1000 Ljubljana (Slovenia)

    2012-01-15

    A highly sensitive laboratory methodology for simultaneous determination of methylation and reduction of spiked inorganic mercury (Hg{sup 2+}) in marine water labelled with high specific activity radiotracer ({sup 197}Hg prepared from enriched {sup 196}Hg stable isotope) was developed. A conventional extraction protocol for methylmercury (CH{sub 3}Hg{sup +}) was modified in order to significantly reduce the partitioning of interfering labelled Hg{sup 2+} into the final extract, thus allowing the detection of as little as 0.1% of the Hg{sup 2+} spike transformed to labelled CH{sub 3}Hg{sup +}. The efficiency of the modified CH{sub 3}Hg{sup +} extraction procedure was assessed by radiolabelled CH{sub 3}Hg{sup +} spikes corresponding to concentrations of methylmercury between 0.05 and 4 ng L{sup -1}. The recoveries were 73.0{+-}6.0% and 77.5{+-}3.9% for marine and MilliQ water, respectively. The reduction potential was assessed by purging and trapping the radiolabelled elemental Hg in a permanganate solution. The method allows detection of the reduction of as little as 0.001% of labelled Hg{sup 2+} spiked to natural waters. To our knowledge, the optimised methodology is among the most sensitive available to study the Hg methylation and reduction potential, therefore allowing experiments to be done at spikes close to natural levels (1-10 ng L{sup -1}). - Highlights: Black-Right-Pointing-Pointer Inorganic mercury methylation and reduction in marine water were studied. Black-Right-Pointing-Pointer High specific activity {sup 197}Hg was used to label Hg{sup 2+} spikes at natural levels. Black-Right-Pointing-Pointer Methylmercury extraction had 73% efficiency for 0.05-4 ng L{sup -1} levels. Black-Right-Pointing-Pointer High sensibility to assess methylation potentials, below 0.1% of the spike. Black-Right-Pointing-Pointer High sensibility also for reduction potentials, as low as 0.001% of the spike.

  12. A novel technique for extracting clouds base height using ground based imaging

    Directory of Open Access Journals (Sweden)

    E. Hirsch

    2011-01-01

    Full Text Available The height of a cloud in the atmospheric column is a key parameter in its characterization. Several remote sensing techniques (passive and active, either ground-based or on space-borne platforms and in-situ measurements are routinely used in order to estimate top and base heights of clouds. In this article we present a novel method that combines thermal imaging from the ground and sounded wind profile in order to derive the cloud base height. This method is independent of cloud types, making it efficient for both low boundary layer and high clouds. In addition, using thermal imaging ensures extraction of clouds' features during daytime as well as at nighttime. The proposed technique was validated by comparison to active sounding by ceilometers (which is a standard ground based method, to lifted condensation level (LCL calculations, and to MODIS products obtained from space. As all passive remote sensing techniques, the proposed method extracts only the height of the lowest cloud layer, thus upper cloud layers are not detected. Nevertheless, the information derived from this method can be complementary to space-borne cloud top measurements when deep-convective clouds are present. Unlike techniques such as LCL, this method is not limited to boundary layer clouds, and can extract the cloud base height at any level, as long as sufficient thermal contrast exists between the radiative temperatures of the cloud and its surrounding air parcel. Another advantage of the proposed method is its simplicity and modest power needs, making it particularly suitable for field measurements and deployment at remote locations. Our method can be further simplified for use with visible CCD or CMOS camera (although nighttime clouds will not be observed.

  13. Extraction and quantification of polyphenols from kinnow (Citrus reticulate L. peel using ultrasound and maceration techniques

    Directory of Open Access Journals (Sweden)

    Muhammad N. Safdar

    2017-07-01

    Full Text Available An investigation was carried out to extract polyphenols from the peel of kinnow (Citrus reticulate L. by maceration and ultrasound-assisted extraction (UAE techniques. The antioxidant potential of these polyphenols was evaluated using ferric reducing antioxidant power (FRAP, 2,2-diphenyl-1-picrylhydrazyl (DPPH, and superoxide radical scavenging assays; and their antimicrobial activity was assessed against bacterial strains Staphyloccoccus aureus, Bacillus cereus, and Salmonella typhimurium. The highest extraction yield was obtained through the solvent ethanol at 80% concentration level, whereas UAE was a more efficient technique and yielded comparatively higher polyphenol contents than maceration. Maximum polyphenols were extracted with 80% methanol [32.48 mg gallic acid equivalent (GAE/g extract] using UAE, whereas minimum phenolics (8.64 mg GAE/g extract were obtained with 80% ethyl acetate through the maceration technique. Elevated antioxidant activity of kinnow peel extracts was exhibited in three antioxidant assays, where 80% methanolic extracts showed the highest antioxidant activity (27.67±1.11mM/100 g for FRAP and the highest scavenging activity, 72.83±0.65% and 64.80±0.91% for DPPH and superoxide anion radical assays, respectively. Strong correlations between total polyphenols and antioxidant activity were recorded. Eleven phenolic compounds—including five phenolic acids and six flavonoids—were identified and quantified by high performance liquid chromatography. Ferulic acid and hesperidin were the most abundant compounds whereas caffeic acid was the least abundant phenolic compound in kinnow peel extracts. Maximum inhibition zone was recorded against S. aureus (16.00±0.58 mm whereas minimum inhibition zone was noted against S. typhimurium (9.00±1.16 mm. It was concluded that kinnow mandarin peels, being a potential source of phenolic compounds with antioxidant and antimicrobial properties, may be used as an ingredient for

  14. A new technique of laparoscopic intracorporeal anastomosis for transrectal bowel resection with transvaginal specimen extraction.

    Science.gov (United States)

    Faller, Emilie; Albornoz, Jaime; Messori, Pietro; Leroy, Joël; Wattiez, Arnaud

    2013-01-01

    To show a new technique of laparoscopic intracorporeal anastomosis for transrectal bowel resection with transvaginal specimen extraction, a technique particularly suited for treatment of bowel endometriosis. Step-by-step explanation of the technique using videos and pictures (educative video). Endometriosis may affect the bowel in 3% to 37% of all endometriosis cases. Bowel endometriosis affects young women, without any co-morbidities and in particular without any vascular disorders. In addition, affected patients often express a desire for childbearing. Radical excision is sometimes required because of the impossibility of conservative treatment such as shaving, mucosal skinning, or discoid resection. Bowel endometriosis should not be considered a cancer, and consequently maximal resection is not the objective. Rather, the goal would be to achieve functional benefit. As a result, resection must be as economic and cosmetic as possible. The laparoscopic approach has proved its superiority over the open technique, although mini-laparotomy is generally performed to prepare for the anastomosis. Total laparoscopic approach in patients with partial bowel stenosis, using the vagina for specimen extraction. This technique of intracorporeal anastomosis with transvaginal specimen extraction enables a smaller resection and avoidance of abdominal incision enlargement that may cause hernia, infection, or pain. When stenosis is partial, this technique seems particularly suited for treatment of bowel endometriosis requiring resection. If stenosis is complete, the anvil can be inserted above the lesion transvaginally. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  15. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent

    2012-01-01

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t’am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  16. Piezoelectric Versus Conventional Rotary Techniques for Impacted Third Molar Extraction

    Science.gov (United States)

    Jiang, Qian; Qiu, Yating; Yang, Chi; Yang, Jingyun; Chen, Minjie; Zhang, Zhiyuan

    2015-01-01

    Abstract Impacted third molars are frequently encountered in clinical work. Surgical removal of impacted third molars is often required to prevent clinical symptoms. Traditional rotary cutting instruments are potentially injurious, and piezosurgery, as a new osteotomy technique, has been introduced in oral and maxillofacial surgery. No consistent conclusion has been reached regarding whether this new technique is associated with fewer or less severe postoperative sequelae after third molar extraction. The aim of this study was to compare piezosurgery with rotary osteotomy techniques, with regard to surgery time and the severity of postoperative sequelae, including pain, swelling, and trismus. We conducted a systematic literature search in the Cochrane Library, PubMed, Embase, and Google Scholar. The eligibility criteria of this study included the following: the patients were clearly diagnosed as having impacted mandibular third molars; the patients underwent piezosurgery osteotomy, and in the control group rotary osteotomy techniques, for removing impacted third molars; the outcomes of interest include surgery time, trismus, swelling or pain; the studies are randomized controlled trials. We used random-effects models to calculate the difference in the outcomes, and the corresponding 95% confidence interval. We calculated the weighted mean difference if the trials used the same measurement, and a standardized mean difference if otherwise. A total of seven studies met the eligibility criteria and were included in our analysis. Compared with rotary osteotomy, patients undergoing piezosurgery experienced longer surgery time (mean difference 4.13 minutes, 95% confidence interval 2.75–5.52, P piezosurgery groups. The number of included randomized controlled trials and the sample size of each trial were relatively small, double blinding was not possible, and cost analysis was unavailable due to a lack of data. Our meta-analysis indicates that although patients

  17. Automated PET Radiotracer Manufacture on the BG75 System and Imaging Validation Studies of [18F]fluoromisonidazole ([18F]FMISO).

    Science.gov (United States)

    Yuan, Hong; Frank, Jonathan E; Merrill, Joseph R; Hillesheim, Daniel A; Khachaturian, Mark H; Anzellotti, Atilio I

    2016-01-01

    The hypoxia PET tracer, 1-[18F]fluoro-3-(2-nitro-1Himidazol- 1-yl)-propan-2-ol ([18F]FMISO) is the first radiotracer developed for hypoxia PET imaging and has shown promising for cancer diagnosis and prognosis. However, access to [18F]FMISO radiotracer is limited due to the needed cyclotron and radiochemistry expertise. The study aimed to develop the automated production method on the [18F]FMISO radiotracer with the novel fully automated platform of the BG75 system and validate its usage on animal tumor models. [18F]FMISO was produced with the dose synthesis cartridge automatically on the BG75 system. Validation of [18F]FMISO hypoxia imaging functionality was conducted on two tumor mouse models (FaDu/U87 tumor). The distribution of [18F]FMISO within tumor was further validated by the standard hypoxia marker EF5. The average radiochemical purity was (99±1) % and the average pH was 5.5±0.2 with other quality attributes passing standard criteria (n=12). Overall biodistribution for [18F]FMISO in both tumor models was consistent with reported studies where bladder and large intestines presented highest activity at 90 min post injection. High spatial correlation was found between [18F]FMISO autoradiography and EF5 hypoxia staining, indicating high hypoxia specificity of [18MF]FMISO. This study shows that qualified [18F]FMISO can be efficiently produced on the BG75 system in an automated "dose-on-demand" mode using single dose disposable cards. The possibilities of having a low-cost, automated system manufacturing ([18F]Fluoride production + synthesis + QC) different radiotracers will greatly enhance the potential for PET technology to reach new geographical areas and underserved patient populations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Electronic techniques for subsea oil exploration and extraction

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Subsea oil exploration and extraction is becoming increasingly difficult, costly, and dangerous. Electronics is contributing to make offshore work easier and safer. It is used for positioning ships or oil rigs, for remotely controlling well-heads and tool reentry operations, for pipelaying operations, and for monitoring underwater equipment. It is also tending to replace men in diving operations. The specific achievements of THOMPSON--CSF in this field are described. Fully automated operation of the winches on the ETPM 1601 barge proved successful during a recent pipelaying operation. The technique used by THOMPSON--CSF in this venture allowed a single operator to control all the maneuvers. These are briefly described. (MCW)

  19. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  20. Uses and limits of radiotracers in the study of drugs and xenobiotics metabolism

    International Nuclear Information System (INIS)

    Cohen, Y.

    1980-01-01

    This review deals with scientific papers issued in 1977-1978, on labelling of drugs and xenobiotics and their metabolism. It is divided in five parts: site of label; in vivo metabolism in animals and human beings; in vitro metabolism on tissue slices, cells culture, microsomes, membrane receptors; metabolism of xenobiotics: nutrients, food additives, detergents, plastics and fabrics; discussion. Metabolic studies, nowadays, associate radiotracers, stable isotopes with high performing procedures for analytical separation [fr

  1. Speciation of Fe(II) and Fe(III) in Contaminated Aquifer Sediments Using Chemical Extraction Techniques

    DEFF Research Database (Denmark)

    Heron, Gorm; Crouzet, Catherine.; Bourg, Alain C. M.

    1994-01-01

    The iron mineralogy of aquifer sediments was described by chemical extraction techniques. Single-step extractions including 1 M CaC12, NaAc, oxalate, dithionite, Ti(II1)- EDTA, 0.5 M HC1,5 M HC1, hot 6 M HC1, and a sequential extraction by HI and CrIIHC1 were tested on standard iron minerals...... species are distinguished as AVS (acid volatile sulfide, hot 6 M HC1 extraction) and pyrite (sequential HI and CrIIHC1 extraction). By including a cold 5 M HC1 extraction, the total distribution of the major reactive Fe(I1) and Fe(II1) fractions in aquifer sediments can be assessed....

  2. Techniques to extract physical modes in model-independent analysis of rings

    International Nuclear Information System (INIS)

    Wang, C.-X.

    2004-01-01

    A basic goal of Model-Independent Analysis is to extract the physical modes underlying the beam histories collected at a large number of beam position monitors so that beam dynamics and machine properties can be deduced independent of specific machine models. Here we discuss techniques to achieve this goal, especially the Principal Component Analysis and the Independent Component Analysis.

  3. A feasibility study of H{sup -} beam extraction technique using YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Meigo, Shin-ichiro; Hasegawa, Kazuo; Ikeda, Yujiro; Oigawa, Hiroyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Aoki, Nobutada [Toshiba Power System Co., Ltd. (Japan); Nakagawa, Satoshi [Toshiba Co., Tokyo (Japan)

    2002-12-01

    Under a framework of JAERI-KEK joint project of high intensity proton accelerator, as for research and develop of the accelerator driven nuclear transmutation of the long lived radioactive nuclide, it is planed to built the Transmutation Physics Experiment Facility (TEF-P) and the Transmutation Engineering Experiment Facility (TEF-E). The TEF-P is used for the experiments for subcritical system coupled with a spallation neutron target bombarded with 600-MeV proton beam accelerated by the LINAC. To limit the maximum thermal power less than 500 W at the TEF-P, an incident beam power should be less than 10 W. On the contrary, at the TEF-E, high power beam of 200 kW is requested. Both high and low power beams are demanded for the transmutation facilities. It is difficult to deliver a low power beam to the TEF-P. Conventional beam extraction technique with a thin foil, is not desirable because the scattering of the beam at the foil requires the massive shield. Therefore, we study a new technique to extract a small portion of the beam precisely from the high intensity beam by using a laser beam. By a laser beam, H{sup -} in the beam from LINAC is partially changed to H{sup 0} beam so that a low current H{sup 0} beam can be obtained. As the cross section of the charge exchange reaction for H{sup -} ions has a peak around at a wave length of 1 {mu}m for photons, YAG laser is suitable for this charge exchange because of its 1.06 {mu}m wave length. It is derived that 10 W beam for 600-MeV proton can be extracted by the YAG laser with power of 2 J for each pulse of 25 Hz. By this technique, the pulse width for the extracted beam can be controlled by changing the time width of laser irradiation. When a charge exchanger having the beam collide point existing in straight section, a background beam current of projectile, however, will be increased due to the interaction with the residual gas in the beam duct. Thus, a charge exchanger is devised having the beam collide point in a

  4. Microscope-integrated intraoperative optical coherence tomography-guided small-incision lenticule extraction: New surgical technique.

    Science.gov (United States)

    Sharma, Namrata; Urkude, Jayanand; Chaniyara, Manthan; Titiyal, Jeewan S

    2017-10-01

    We describe the surgical technique of microscope-integrated intraoperative optical coherence tomography (OCT)-guided small-incision lenticule extraction. The technique enables manual tracking of surgical instruments and identification of the desired dissection plane. It also helps discern the relation between the dissector and the intrastromal lenticule. The dissection plane becomes hyperreflective on dissection, ensuring complete separation of the intrastromal lenticule from the overlying and underlying stroma. Inadvertent posterior plane entry, cap-lenticule adhesion, incomplete separation of the lenticule, creation of a false plane, and lenticule remnants may be recognized intraoperatively so corrective steps can be taken immediately. In cases with a hazy overlying cap, microscope-integrated intraoperative OCT enables localization and extraction of the lenticule. The technique is helpful for inexperienced surgeons, especially in cases with low amplitudes of refractive errors, ie, thin lenticules. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a vacuum pan for massecuite b and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the o n line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  6. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a Vacuum Pan for massecuite B and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the Ion Line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  7. Study of a new hepatobiliary radiotracer: sup(99m)Tc diethyl IDA. Its value in the diagnosis of cholestasis

    International Nuclear Information System (INIS)

    Roques, J.F.

    1979-01-01

    This work examines a new means of investigation: Technetium 99 (2,6 diethyl acetanilido) imino-diacetic acid, or HEPATOBIDA, hepatobiliary scintigraphy. A survey of different scintigraphic techniques is necessary. At first the kinetic study of hepatobiliary radiotracers was carried out with multiprobe systems giving quantitative information on the various organs or pools concerned. With the appearance of the scintillation camera it became possible to obtain not only quantitative data but also topographical and morphological information. Since 1976 the derivatives of iminodiacetic acid have been widely adopted, possessing features most closely resembling those of the ideal hepatobiliatropic molecules. Examinations have been performed at the Angers Radioisotopes Service with the diethyl derivative or HEPATOBIDA (Nuclear Solca Lab.) The results recorded in a group of cholestasis patients are studied, with normal data supplied by a set of 8 reference subjects free from hepatobiliary diseases [fr

  8. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Radionuclide dosimetry must, by its nature, define tissue irradiation in terms of mean exposure in a population of a statistically acceptable size. In the daily practice of clinical nuclear medicine there are, however, quite large variations in the biodistribution of tracers and thus in resulting radiation doses. Age is a variable, particularly in respect of bone-seeking tracers. Sex imposes variations in radiation dose on account of the differing anatomical configurations of the gonads. Breast uptake and excretion of certain tracers in women are additional variables. Activity and occupation are occasional variables. Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggest that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  9. Studies of soils erosion in Protected Areas of Cienfuegos, Cuba, using Cesium - 137 as radiotracer

    International Nuclear Information System (INIS)

    Sibello Hernandez, Rita Y.; Febles Gonzalez, Jose M.

    2011-01-01

    The large-scale nuclear explosions that had taken place due to the nuclear weapons tests or as a result of nuclear accidents are the main causes of the great dispersion of artificial radionuclides around the world. One of these radionuclides is Cesium-137, which is strongly fixed to the fine soils particles. This fact, together with its half-life of 30 years and its easy detection by gamma spectrometry have converted Cesium-137, in a good radiotracer of the soils movement. This technique has been widely used and validated in different landscapes throughout the world. Its effectiveness was also previously validated and proved in Cienfuegos province too. This research was aimed at using the Cesium-137 technique to study soil redistribution and quantify erosion in the called Protected Areas in Cienfuegos province, where soil loss and sediment transport are the main causes of deterioration of these ecosystems with the consequent economic and / or environmental losses. The results were represented in a map using the software gvSIG by kriging, achieving greater visibility of the soil redistribution in the plot studied. The methodology used in this study can be used in other places wherever it is necessary to know the magnitude of the erosion problems and to know the soil redistribution pattern in the landscape which can be very useful to draw the plans for reorganization of land use.(author)

  10. A novel murmur-based heart sound feature extraction technique using envelope-morphological analysis

    Science.gov (United States)

    Yao, Hao-Dong; Ma, Jia-Li; Fu, Bin-Bin; Wang, Hai-Yang; Dong, Ming-Chui

    2015-07-01

    Auscultation of heart sound (HS) signals serves as an important primary approach to diagnose cardiovascular diseases (CVDs) for centuries. Confronting the intrinsic drawbacks of traditional HS auscultation, computer-aided automatic HS auscultation based on feature extraction technique has witnessed explosive development. Yet, most existing HS feature extraction methods adopt acoustic or time-frequency features which exhibit poor relationship with diagnostic information, thus restricting the performance of further interpretation and analysis. Tackling such a bottleneck problem, this paper innovatively proposes a novel murmur-based HS feature extraction method since murmurs contain massive pathological information and are regarded as the first indications of pathological occurrences of heart valves. Adapting discrete wavelet transform (DWT) and Shannon envelope, the envelope-morphological characteristics of murmurs are obtained and three features are extracted accordingly. Validated by discriminating normal HS and 5 various abnormal HS signals with extracted features, the proposed method provides an attractive candidate in automatic HS auscultation.

  11. Radiotracer study on dispersion of sewerage off Mumbai Coast in Western India

    International Nuclear Information System (INIS)

    Kumar, U.S.; Yelgaonkar, V.N.; Navada, S.V.

    1997-01-01

    Municipal Corporation of Greater Mumbai discharges the treated sewage at various locations off Mumbai coast. One such discharge point is located near Colaba near South Mumbai. Screened, degritted and aerated sewage is discharged through a 1 m diameter steel pipe by gravity to the diffuser installed on the sea bed at 1.1 km away from the shore. A radiotracer study was carried out to evaluate the dilution and dispersion pattern of the sewage at different points from the disposal point. The experiment was carried out during high tide. About 110 GBq of 82 Br was used as the tracer. A dilution factor of about 5.5 x 10 3 was obtained at a distance of 4.3 km from the outfall. The dilution downshore was small even for a long distance due to strong unidirectional currents. Comparable dilution factors were also obtained by Brooks' model. Vertical tracer profiles showed that the waste plume was well mixed over a depth of 2 to 3 m from the surface. A 2-D advection simulation model was employed to simulate the spatial and temporal distribution of the radiotracer data. From the model simulation best fit was obtained for dispersion coefficients Dx = 15 m 2 .s -1 and Dy = 2m 2 .s -1 . The dispersion coefficients can be used for predicting the effluent dispersion under different outfall and disposal conditions. The tracer pattern at Colaba and Malad indicated no possibility of contamination of the beaches

  12. UV-photochemical vapor generation of selenium for atomic absorption spectrometry: Optimization and 75Se radiotracer efficiency study

    Czech Academy of Sciences Publication Activity Database

    Rybínová, M.; Musil, Stanislav; Červený, J.; Vobecký, Miloslav; Rychlovský, P.

    2016-01-01

    Roč. 123, SEP (2016), s. 134-142 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Institutional support: RVO:68081715 Keywords : UV-photochemical vapor generation * Selenium * 75Se radiotracer Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.241, year: 2016

  13. In Vivo Imaging of Experimental Melanoma Tumors using the Novel Radiotracer 68Ga-NODAGA-Procainamide (PCA).

    Science.gov (United States)

    Kertész, István; Vida, András; Nagy, Gábor; Emri, Miklós; Farkas, Antal; Kis, Adrienn; Angyal, János; Dénes, Noémi; Szabó, Judit P; Kovács, Tünde; Bai, Péter; Trencsényi, György

    2017-01-01

    The most aggressive form of skin cancer is the malignant melanoma. Because of its high metastatic potential the early detection of primary melanoma tumors and metastases using non-invasive PET imaging determines the outcome of the disease. Previous studies have already shown that benzamide derivatives, such as procainamide (PCA) specifically bind to melanin pigment. The aim of this study was to synthesize and investigate the melanin specificity of the novel 68 Ga-labeled NODAGA-PCA molecule in vitro and in vivo using PET techniques. Procainamide (PCA) was conjugated with NODAGA chelator and was labeled with Ga-68 ( 68 Ga-NODAGA-PCA). The melanin specificity of 68 Ga-NODAGA-PCA was tested in vitro , ex vivo and in vivo using melanotic B16-F10 and amelanotic Melur melanoma cell lines. By subcutaneous and intravenous injection of melanoma cells tumor-bearing mice were prepared, on which biodistribution studies and small animal PET/CT scans were performed for 68 Ga-NODAGA-PCA and 18 FDG tracers. 68 Ga-NODAGA-PCA was produced with high specific activity (14.9±3.9 GBq/µmol) and with excellent radiochemical purity (98%PCA uptake of B16-F10 cells was significantly ( p ≤0.01) higher than Melur cells. Ex vivo biodistribution and in vivo PET/CT studies using subcutaneous and metastatic tumor models showed significantly ( p ≤0.01) higher 68 Ga-NODAGA-PCA uptake in B16-F10 primary tumors and lung metastases in comparison with amelanotic Melur tumors. In experiments where 18 FDG and 68 Ga-NODAGA-PCA uptake of B16-F10 tumors was compared, we found that the tumor-to-muscle (T/M) and tumor-to-lung (T/L) ratios were significantly ( p ≤0.05 and p ≤0.01) higher using 68 Ga-NODAGA-PCA than the 18 FDG accumulation. Our novel radiotracer 68 Ga-NODAGA-PCA showed specific binding to the melanin producing experimental melanoma tumors. Therefore, 68 Ga-NODAGA-PCA is a suitable diagnostic radiotracer for the detection of melanoma tumors and metastases in vivo .

  14. Chemistry and biology of radiotracers that target changes in sympathetic and parasympathetic nervous systems in heart disease.

    Science.gov (United States)

    Eckelman, William C; Dilsizian, Vasken

    2015-06-01

    Following the discovery of the sympathetic and parasympathetic nervous system, numerous adrenoceptor drugs were radiolabeled and potent radioligands were prepared in order to image the β-adrenergic and the muscarinic systems. But the greatest effort has been in preparing noradrenaline analogs, such as norepinephrine, (11)C-metahydroxyephedrine, and (123)I-metaiodobenzylguanidine that measure cardiac sympathetic nerve varicosities. Given the technical and clinical challenges in designing and validating targeted adrenoceptor-binding radiotracers, namely the heavily weighted flow dependence and relatively low target-to-background ratio, both requiring complicated mathematic analysis, and the inability of targeted adrenoceptor radioligands to have an impact on clinical care of heart disease, the emphasis has been on radioligands monitoring the norepinephrine pathway. The chemistry and biology of such radiotracers, and the clinical and prognostic impact of these innervation imaging studies in patients with heart disease, are examined. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Comparative study of modern extraction techniques for the determination of environmental samples (M14)

    International Nuclear Information System (INIS)

    Gfrerer, M.; Lankmayr, E.

    2002-01-01

    Full text: The aim of any extraction method in analytical chemistry is, to effectively separate the analytes from the matrix. The whole step should be fast and quantitative with minimal solvent and time required. The classical Soxhlet extraction usually requires large volumes (up to 200 ml) of solvent to be refluxed through the solid samples for several hours. Therefore, in the last decades, alternatives for this extraction method have been presented and investigated such as ultrasonic extraction (UE), supercritical fluid extraction (SFE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and fluidized-bed extraction (FBE). The actual choice for analytical application is frequently the initial capital cost, operating costs, simplicity of operation, amount of organic solvent required and sample throughput. Since sample preparation is a critical step in the analytical cycle, special care has to be taken for an accurate choice and optimization of extraction techniques and clean-up procedures. Therefore, MAE and FBE were investigated for their influential extraction parameters and these parameters were optimized for the extraction of organochlorine biocides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons from environmental matrices like soil, sediment and sewage sludge. The extraction yields were compared with those obtained by Soxhlet extraction performed following DIN-methods. Finally, the optimized modern methods were validated by systematic experiments with certified reference materials. Refs. 3 (author)

  16. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    Science.gov (United States)

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  17. Effects of processing parameters on the caffeine extraction yield during decaffeination of black tea using pilot-scale supercritical carbon dioxide extraction technique.

    Science.gov (United States)

    Ilgaz, Saziye; Sat, Ihsan Gungor; Polat, Atilla

    2018-04-01

    In this pilot-scale study supercritical carbon dioxide (SCCO 2 ) extraction technique was used for decaffeination of black tea. Pressure (250, 375, 500 bar), extraction time (60, 180, 300 min), temperature (55, 62.5, 70 °C), CO 2 flow rate (1, 2, 3 L/min) and modifier quantity (0, 2.5, 5 mol%) were selected as extraction parameters. Three-level and five-factor response surface methodology experimental design with a Box-Behnken type was employed to generate 46 different processing conditions. 100% of caffeine from black tea was removed under two different extraction conditions; one of which was consist of 375 bar pressure, 62.5 °C temperature, 300 min extraction time, 2 L/min CO 2 flow rate and 5 mol% modifier concentration and the other was composed of same temperature, pressure and extraction time conditions with 3 L/min CO 2 flow rate and 2.5 mol% modifier concentration. Results showed that extraction time, pressure, CO 2 flow rate and modifier quantity had great impact on decaffeination yield.

  18. Comparison of the Effectiveness of Water-Based Extraction of Substances from Dry Tea Leaves with the Use of Magnetic Field Assisted Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Grzegorz Zaguła

    2017-10-01

    Full Text Available This article presents the findings of a study investigating the feasibility of using a magnetic field assisted technique for the water-based extraction of mineral components, polyphenols, and caffeine from dry black and green tea leaves. The authors present a concept of applying constant and variable magnetic fields in the process of producing water-based infusions from selected types of tea. Analyses investigating the effectiveness of the proposed technique in comparison with conventional infusion methods assessed the contents of selected mineral components—i.e., Al, Ca, Cu, K, Mg, P, S, and Zn—which were examined with the use of ICP-OES. The contents of caffeine and polyphenolic compounds were assessed using the HPLC. A changing magnetic field permitted an increased effectiveness of extraction of the mineral components, caffeine, and polyphenols. The findings support the conclusion that a changing magnetic field assisted extraction method is useful for obtaining biologically valuable components from tea infusions.

  19. Coacervative extraction as a green technique for sample preparation for the analysis of organic compounds.

    Science.gov (United States)

    Melnyk, A; Wolska, L; Namieśnik, J

    2014-04-25

    One of the present trends in analytical chemistry is miniaturization, which is one of the methods of green analytical chemistry application. A particular emphasis is placed on the elimination of the use of large amounts of organic solvents which are toxic and harmful to the environment, maintaining high efficiency of the extraction process, high recovery values and low values of quantification (LOQ) and detection (LOD) limits. These requirements are fulfilled by coacervative extraction (CAE) technique. In this review, theoretical aspects of the coacervation process are presented along with environmental and bioanalytical applications of this technique, its advantages, limitations and competitiveness with other techniques. Due to its simplicity and rapidity, CAE is an excellent alternative for currently practiced procedures of sample preparation for the analysis of organic compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Experimental procedure for determination of dispersion coefficient in a column of porous medium using radiotracer; Procedimento experimental para determinacao do coeficiente de dispersao num meio poroso em coluna utilizando radiotracador

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Roberto de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia; Heilbron Filho, Paulo Fernando Lavalle [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    1997-12-31

    The experimental procedures used for determination of parameters such as the molecular diffusion and the diffusion by mechanical convection, responsible for the dispersion in the porous medium, are presented. The experiments were conduct in a column, based on the theory of hydrodynamic dispersion. The radiotracer technique was employed to monitor the dispersion of the radioactive cloud through the porous medium. The radionuclide employed was the bromide 82 (Br{sup 82}), in the KBr chemical form 11 refs., 5 figs., 4 tabs.; e-mail: rs at serv.com.ufrj.br; paulo at cnen.gov.br

  1. Reactor and /or accelerator: general remarks on strategic considerations in sourcing/producing radiopharmaceuticals and radiotracer for the Philippines

    International Nuclear Information System (INIS)

    Nazarea, A.D.

    1996-01-01

    The most important sources of radionuclides in the world are particle accelerators and nuclear reactors. Since the late 1940's many radiotracers and radiopharmaceuticals have been innovated and conceived, designed, produced and applied in important industrial and clinical/ biomedical settings. For example in the health area, reactor-produced radionuclides have become indispensable for diagnostic imaging involving, in its most recent and advanced development, radioimmunoscintigraphy, which exploits the exquisite ligand-specificity of monoclonal antibodies, reagents which in turn are the products of advances in biotechnology. Thus far, one of the most indispensable radiopharmaceuticals has been 99m Tc, which is usually obtained as a daughter decay product of 99 Mo. In January 1991, some questions about the stability of the worldwide commercial supply of 99 Mo became highlighted when the major commercial world producer of 99 Mo, Nordion International, shut down its facilities temporarily in Canada due to contamination in its main reactor building (see for instance relevant newsbrief in J. Nuclear Medicine (1991): 'Industry agrees to join DOE study of domestic moly-99 production'). With the above background, my remarks will attempt to open discussions on strategic considerations relevant to questions of 'self reliance' in radiotracers/radiopharmaceutical production in the Philippines. For instance, the relevant question of sourcing local radionuclide needs from a fully functioning multipurpose cyclotron facility within the country that will then supply the needs of the local industrial, biomedical (including research) and health sectors; and possibly, eventually acquiring the capability to export to nearby countries longer-lived radiotracers and radiopharmaceuticals

  2. Imaging of Non-Prostate Cancers Using PSMA-Targeted Radiotracers: Rationale, Current State of the Field, and a Call to Arms.

    Science.gov (United States)

    Salas Fragomeni, Roberto A; Amir, Tali; Sheikhbahaei, Sara; Harvey, Susan C; Javadi, Mehrbod S; Solnes, Lilja; Kiess, Ana; Allaf, Mohamad E; Pomper, Martin; Gorin, Michael A; Rowe, Steven P

    2018-03-15

    Prostate-specific membrane antigen (PSMA) is a type II transmembrane glycoprotein that is highly overexpressed on prostate cancer epithelial cells and for which there is a growing body of literature examining the role of small molecule and antibody radiotracers targeted against this protein for prostate cancer detection and therapy. Despite its name, PSMA is also expressed, to varying degrees, in the neovasculature of a wide variety of non-prostate cancers; indeed, the pathology literature is replete with promising immunohistochemistry findings. A number of groups have begun to correlate those pathology-level results with in vivo imaging and therapy in non-prostate cancers using the same PSMA-targeted agents that have been so successful in prostate cancer. The potential to leverage radiotracers targeted to PSMA beyond prostate cancer is a promising approach for many cancers, and PSMA-targeted agents may be able to supplement or fill gaps left by other agents. However, to date, the majority of the reported findings with PSMA-targeted radiotracers in non-prostate malignancies has been in case reports and small case series, and the field must adopt a more thorough approach to the design and execution of larger prospective trials in order to realize the potential of these promising agents outside of prostate cancer. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Biodistribution of gyroxin using 125I as radiotracer

    International Nuclear Information System (INIS)

    Alves da Silva, J.A.; Ribela, M.T.C.P.; Rogero, J.R.; Camillo, M.A.P.; Muramoto, E.

    2006-01-01

    The use of radiotracers in the research of animal venom has been scarce, although it allows an excellent approach to follow the process of bioavailability, biodistribution and kinetics of toxins. The purpose of this study was to assess gyroxin action mechanism, transport, compartments and action sites. This toxin is a thrombin-like and causes the barrel rotation syndrome. The gyroxin was labeled with 125 I and used as a tracer for the in vivo assay in mice. Blood samples and organs were collected at different time intervals, weighed and analyzed in a gamma-counter. The data was related with tissues distribution of protease activated receptor (PAR). Biodistribution assay allowed dividing the organs into three groups. The first one with the organs that followed the blood kinetics, the second with the organs related to metabolisms and elimination, and the third with the organs in which the gyroxin concentration increased during the observation period. (author)

  4. Design of laboratory radiotracer studies in marine radioecology

    International Nuclear Information System (INIS)

    Schulte, E.H.

    1997-01-01

    A condensed description of methods used in laboratory radiotracer studies in marine radioecology is presented showing also the difficulties which may be encountered in order to obtain realistic and comparable information on the general behaviour of radionuclides in marine organisms. Practical guidance on the choice of the biological material and how to setup laboratory experiments and to control properly important experimental conditions are given. Key parameters like concentration factors and biological half-lives are defined and the theoretical estimation and practical determination of input, uptake, accumulation and loss of radionuclides in marine biota are formulated by the aid of mathematical equations. Examples of uptake and loss curves obtained in the laboratory are shown. The importance of some environmental factors (temperature, food, growth) on uptake and loss of radionuclides are demonstrated. Comparison of experimental and field data of concentration factors is reported to show the difficulty in extrapolating from laboratory experiments to nature. (author)

  5. Determination of inositol phosphate ester in lake sediments

    International Nuclear Information System (INIS)

    Weimer, W.C.; Armstrong, D.E.

    1977-01-01

    A procedure for the determination of the total inositol polyphosphate content of lake sediments is presented and evaluated. This technique involves extraction with NaOH, cleanup of the extract, and isolation and identification of two groups of inositol phosphate esters by ion-exchange chromatography. Radioisotope dilution is employed to correct for losses during the extraction, cleanup and isolation steps. Recoveries of the radiotracer inositol phosphates have averaged 85% during the analysis of approximately 40 calcareous and non-calcareous sediment samples and more than 20 soil samples

  6. Radiotracers for per studies of neurotransmitter binding sites: Design considerations

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    Neurotransmitter binding sites, such as receptors, neuronal uptake systems, and vesicular uptake systems, are important targets for new radiopharmaceutical design. Selection of potential radioligands can be guided by in vitro laboratory data including such characteristics as selectivity and affinity for specific binding sites. However, development of PET radiotracers for use in vivo must include considerations of in vivo pharmacokinetics and metabolism. Introduction of potential radioligands is further narrowed by the demands of the radiochemical synthesis, which must produce radioligands of high chemical and radiochemical purity and of high specific activity. This paper will review examples of previous and current attempts by radiopharmaceutical chemists to meet these demands for new positron emitter-labeled radioligands for PET studies of a wide array of neurotransmitter binding sites

  7. Applied radiotracer techniques for studying pollutant bioaccumulation in selected marine organisms (jellyfish, crabs and sea stars)

    International Nuclear Information System (INIS)

    Fowler, S.W.; Teyssie, J.-L.; Cotret, O.; Danis, B.; Warnau, M.; Rouleau, C.

    2004-01-01

    Obtaining specific information on contaminant biokinetics in marine biota is often necessary for properly interpreting monitoring data on trace contaminant levels in bioindicator species living under varying environmental conditions. Radiotracers have been employed in laboratory experiments to assess the uptake, distribution and retention of selected heavy metals and PCB congeners in three potential marine bioindicators occupying different ecological niches in the coastal zone. Pelagic and benthic jellyfish readily accumulated Co, Ag, Zn, Cd, 137 Cs and 241 Am from both water and food and retained them with biological half-lives (Tb1/2) ranging from a few days to several weeks. Zinc and silver were accumulated to the greatest degree (CF ∼ 4 · 10 2 ), with benthic jellyfish having a greater affinity for metals than the pelagic species. Results from light-dark experiments indicate that the enhanced metal uptake in the benthic jellyfish is due to the presence of endosymbiotic photosynthetic zooxanthellae situated in the arms of organisms. Shore crabs ingesting Ag, a sewage-related contaminant, readily accumulated the metal with male crabs assimilating some 71% and female crabs 51% of the Ag from their food. Moreover, the assimilated fraction of Ag remained virtually immobile in their tissues as evidenced by an extremely long Tb1/2 for depuration of 7.3 years. Sea stars exposed to 14 C-labelled PCB congener no. 153 in sea water accumulated the congener mainly in the body wall and podia reaching lipid weight CFs that ranged between approximately 2 · 10 5 to 4 · 10 5 . In contrast, following exposure in radiolabelled sediments, the corresponding PCB transfer factors in the same tissues were much lower, viz., 3 · 10 2 to 5 · 10 2 . Nevertheless, regardless of the exposure mode, CFs of PCB in the other tissues (digestive system, gonads, pyloric and rectal caeca) were consistently one to two orders of magnitude lower, an observation which suggests that sea star body

  8. Effect of extraction technique on the content and antioxidant activity of crude extract of Anacyclus clavatus flowers and their essential oil composition.

    Science.gov (United States)

    Aliboudhar, Hamza; Tigrine-Kordjani, Nacéra

    2014-01-01

    Anacyclus clavatus is a plant used as food and remedy. The objective of this work was to study the effect of extraction technique on the antioxidant property, total phenol and flavonoid contents of crude extracts from A. clavatus flowers and their essential oil composition. 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay, ferric-reducing power, β-carotene and total antioxidant capacity assays have demonstrated the significant antioxidant ability of different crude extracts obtained by using the following extraction methods: Soxhlet, microwave heating, heat reflux (HRE) and maceration. The activity of the extract obtained by HRE was the highest (112.06 ± 2.89 μg/mL) evaluated by the DPPH assay. Extraction of essential oil was performed by microwave-assisted hydro-distillation (MAHD) and by hydro-distillation (HD). A significant difference was observed in both essential oils, despite the common main family and major constituents, such as artemisia ketone (10.0 ± 0.8% for MAHD vs. 6.5 ± 0.5 for HD) and pinocarvone (4.1 ± 0.4% for MAHD vs. 1.1 ± 0.1% for HD).

  9. Time Domain Feature Extraction Technique for earth's electric field signal prior to the Earthquake

    International Nuclear Information System (INIS)

    Astuti, W; Sediono, W; Akmeliawati, R; Salami, M J E

    2013-01-01

    Earthquake is one of the most destructive of natural disasters that killed many people and destroyed a lot of properties. By considering these catastrophic effects, it is highly important of knowing ahead of earthquakes in order to reduce the number of victims and material losses. Earth's electric field is one of the features that can be used to predict earthquakes (EQs), since it has significant changes in the amplitude of the signal prior to the earthquake. This paper presents a detailed analysis of the earth's electric field due to earthquakes which occurred in Greece, between January 1, 2008 and June 30, 2008. In that period of time, 13 earthquakes had occurred. 6 of them were recorded with magnitudes greater than Ms=5R (5R), while 7 of them were recorded with magnitudes greater than Ms=6R (6R). Time domain feature extraction technique is applied to analyze the 1st significant changes in the earth's electric field prior to the earthquake. Two different time domain feature extraction techniques are applied in this work, namely Simple Square Integral (SSI) and Root Mean Square (RMS). The 1st significant change of the earth's electric field signal in each of monitoring sites is extracted using those two techniques. The feature extraction result can be used as input parameter for an earthquake prediction system

  10. A COMPARATIVE ANALYSIS OF SINGLE AND COMBINATION FEATURE EXTRACTION TECHNIQUES FOR DETECTING CERVICAL CANCER LESIONS

    Directory of Open Access Journals (Sweden)

    S. Pradeep Kumar Kenny

    2016-02-01

    Full Text Available Cervical cancer is the third most common form of cancer affecting women especially in third world countries. The predominant reason for such alarming rate of death is primarily due to lack of awareness and proper health care. As they say, prevention is better than cure, a better strategy has to be put in place to screen a large number of women so that an early diagnosis can help in saving their lives. One such strategy is to implement an automated system. For an automated system to function properly a proper set of features have to be extracted so that the cancer cell can be detected efficiently. In this paper we compare the performances of detecting a cancer cell using a single feature versus a combination feature set technique to see which will suit the automated system in terms of higher detection rate. For this each cell is segmented using multiscale morphological watershed segmentation technique and a series of features are extracted. This process is performed on 967 images and the data extracted is subjected to data mining techniques to determine which feature is best for which stage of cancer. The results thus obtained clearly show a higher percentage of success for combination feature set with 100% accurate detection rate.

  11. Influence of molecularbiological techniques upon nuclearmedical methods; Einfluss molekularbiologischer Verfahren auf nuklearmedizinische Methoden

    Energy Technology Data Exchange (ETDEWEB)

    Haberkorn, U. [Abt. fuer Nuklearmedizin, Klinik fuer Radiologie, Univ. Heidelberg (Germany)

    2005-03-01

    Basic research delivers information concerning new molecular structures with potential use as target structures for diagnosis and therapy with further need for selection and evaluation by the methods of physiology, biochemistry and pharmacology using in part nuclear medical techniques for estimation of gene function and regulation. Pharmacogenomic will identify new surrogate markers as potential new radiotracers for follow-up of therapies. New therapeutical approaches will need biodistribution studies in the preclinical stage and techniques for evaluation of efficiency. At least, biotechnological techniques such as phage display may be suitable to develop new biomolecules for isotope related diagnostics and therapy. (orig.)

  12. A simple and efficient in vitro method for metabolism studies of radiotracers

    International Nuclear Information System (INIS)

    Lee, Sang-Yoon; Choe, Yearn Seong; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo; Kim, Byung-Tae

    2001-01-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[ 18 F]fluoromethylbenzyl- ([ 18 F]1) and 4-[ 18 F]fluorobenzyl-piperidine moieties ([ 18 F]2) was studied and compared with the in vivo metabolism. Defluorination of the [ 18 F]1 mainly occurred to generate [ 18 F]fluoride ion both in vitro and in vivo. In contrast, the [ 18 F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[ 18 F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers

  13. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy, Quick, and Safe Technique

    OpenAIRE

    Gupta, Ravi; Singh, Harpreet; Singh, Amit; Garg, Sudhir

    2014-01-01

    Removal of jammed titanium screws can be difficult due to the problem of stripping of the hexagonal heads of the screws. We present a technique of extraction of stripped screws with the use of a standard 4.5 mm stainless steel hollow mill in a patient of peri-implant fracture of the radius fixed with a titanium locking plate 2 years back. The technique is quick, safe, and cost effective.

  14. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  15. Effects of extraction and derivatization techniques on recovery of organotin species in environmental matrices (W3)

    International Nuclear Information System (INIS)

    Wahlen, R.; Catterick, T.

    2002-01-01

    Full text: Organotin (OT) contamination is still persistent in most coastal environments and estuaries and can be monitored accurately by analysis of sediments and sedentary aquatic animal populations. In addition to human exposure via contaminated seafood, there is increasing concern about OT compounds in man-made consumer products. Organotin analysis involves the extraction from the matrix, derivatization (for GC analysis), separation of the different species and detection. Commonly used extraction techniques are mechanical shaking, ultrasonic agitation and microwave leaching (open or closed vessel). Accelerated solvent extraction (ASE) has also been reported. In this study, closed-vessel microwave extraction and ASE methods are compared for OT analysis in environmental tissues using separation by gas chromatography (GC) and detection by inductively coupled plasma mass-spectrometry (ICP-MS). The efficiency of an ethylation procedure with sodiumtetraethylborate (NABEt 4 ) using different matrices and derivatization durations is monitored by comparing data obtained by external calibration with results by species-specific isotope dilution analysis (SS-IDMS) of dibutyltin (TBT) and dibutyltin (DBT) enriched with 117 Sn. Uncertainty estimates for both quantification techniques will be provided. (author)

  16. Comparison of methods for conducting marine and estuarine sediment porewater toxicity tests—extraction, storage, and handling techniques

    Science.gov (United States)

    Carr, R.S.; Chapman, D.C.

    1995-01-01

    A series of studies was conducted to compare different porewater extraction techniques and to evaluate the effects of sediment and porewater storage conditions on the toxicity of pore water, using assays with the sea urchin Arbacia punctulata. If care is taken in the selection of materials, several different porewater extraction techniques (pressurized squeezing, centrifugation, vacuum) yield samples with similar toxicity. Where the primary contaminants of concern are highly hydrophobic organic compounds, centrifugation is the method of choice for minimizing the loss of contaminants during the extraction procedure. No difference was found in the toxicity of pore water obtained with the Teflon® and polyvinyl chloride pressurized extraction devices. Different types of filters in the squeeze extraction devices apparently adsorbed soluble contaminants to varying degrees. The amount of fine suspended particulate material remaining in the pore water after the initial extraction varied among the methods. For most of the sediments tested, freezing and thawing did not affect the toxicity of porewater samples obtained by the pressurized squeeze extraction method. Pore water obtained by other methods (centrifugation, vacuum) and frozen without additional removal of suspended particulates by centrifugation may exhibit increased toxicity compared with the unfrozen sample.The toxicity of pore water extracted from refrigerated (4°C) sediments exhibited substantial short-term (days, weeks) changes. Similarly, sediment pore water extracted over time from a simulated amphipod solid-phase toxicity test changed substantially in toxicity. For the sediments tested, the direction and magnitude of change in toxicity of pore water extracted from both refrigerated and solid-phase test sediments was unpredictable.

  17. Optimization of cloud point extraction and solid phase extraction methods for speciation of arsenic in natural water using multivariate technique.

    Science.gov (United States)

    Baig, Jameel A; Kazi, Tasneem G; Shah, Abdul Q; Arain, Mohammad B; Afridi, Hassan I; Kandhro, Ghulam A; Khan, Sumaira

    2009-09-28

    The simple and rapid pre-concentration techniques viz. cloud point extraction (CPE) and solid phase extraction (SPE) were applied for the determination of As(3+) and total inorganic arsenic (iAs) in surface and ground water samples. The As(3+) was formed complex with ammonium pyrrolidinedithiocarbamate (APDC) and extracted by surfactant-rich phases in the non-ionic surfactant Triton X-114, after centrifugation the surfactant-rich phase was diluted with 0.1 mol L(-1) HNO(3) in methanol. While total iAs in water samples was adsorbed on titanium dioxide (TiO(2)); after centrifugation, the solid phase was prepared to be slurry for determination. The extracted As species were determined by electrothermal atomic absorption spectrometry. The multivariate strategy was applied to estimate the optimum values of experimental factors for the recovery of As(3+) and total iAs by CPE and SPE. The standard addition method was used to validate the optimized methods. The obtained result showed sufficient recoveries for As(3+) and iAs (>98.0%). The concentration factor in both cases was found to be 40.

  18. Evaluation of bone-seeking novel radiotracer {sup 68}Ga-NO2AP-Bisphosphonate for the detection of skeletal metastases in carcinoma breast

    Energy Technology Data Exchange (ETDEWEB)

    Passah, Averilicia; Tripathi, Madhavi; Ballal, Sanjana; Yadav, Madhav Prasad; Kumar, Rajeev; Chakraborty, Partha Sarathi; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, Ansari Nagar, New Delhi (India); Roesch, Frank; Meckel, Marian [Johannes-Gutenberg-University, Nuclear Chemistry, Mainz (Germany)

    2017-01-15

    The successful labelling of bisphosphonates (BP) with {sup 68}Ga using macrocyclic chelators such as the based triazacyclononane (NO2AP) is a step forward in the in-house availability of a novel bone-seeking PET radiopharmaceutical with dual advantage of PET/CT imaging and generator production. In this study, we compared the novel generator-based skeletal radiotracer {sup 68}Ga-1,4,7-triazacyclonone-1,4-diacetic acid ({sup 68}Ga-NO2AP-BP) with sodium fluoride ({sup 18}F-NaF) for the detection of skeletal metastases in breast cancer patients. In addition, dosimetric analysis of {sup 68}Ga-NO2AP-BP was performed in a subset of patients. This was a prospective study of histopathologically proven cases of breast cancer patients who were referred for bone scintigraphy and underwent positron emission tomography/computed tomography (PET/CT) with {sup 18}F-NaF and {sup 68}Ga-NO2AP-BP within a week in random order. The scans of each patient were compared both qualitatively for image quality and quantitatively for number of lesions and SUVmax of lesions. Dosimetric analysis was performed in five patients. Their PET/CT scans were acquired at multiple time points and urine and blood samples were collected. Dosimetric calculations were performed using OLINDA/EXM 1.1 software. Statistical analysis was done using Stata 13 (StataCorp) software package. An agreement analysis regarding number of lesions detected with the two skeletal radiotracers was carried out. The image quality of {sup 68}Ga-NO2AP-BP PET/CT scans were comparable to that of {sup 18}F-NaF. There was no statistically significant difference in the SUVmax of lesions, normal bone and lesion to background ratio between the two skeletal radiotracers. There was good agreement in the number of lesions detected by both skeletal radiotracers. The mean whole body effective dose for {sup 68}Ga-NO2AP-BP was 0.00583 mSv/MBq and the effective dose equivalent was 0.0086 mSv/MBq. The excellent lesion detection agreement between

  19. Experimental device for obtaining calibration factor for the total count technique

    International Nuclear Information System (INIS)

    Gonçalves, Eduardo R.; Braz, Delson; Brandão, Luís Eduardo B.

    2017-01-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  20. Experimental device for obtaining calibration factor for the total count technique

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Eduardo R.; Braz, Delson [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Brandão, Luís Eduardo B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Reatores

    2017-07-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  1. Effect of DNA extraction methods and sampling techniques on the apparent structure of cow and sheep rumen microbial communities.

    Directory of Open Access Journals (Sweden)

    Gemma Henderson

    Full Text Available Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However

  2. The study of transit time measurement for flow through the central and southern canals of MADA using I-131 radioisotope technique

    International Nuclear Information System (INIS)

    Roslan Mohd Ali; Md Shahid Ayub; Zainuddin Othman; Juhari Yusof; Mohd Asri Ramli; Eow Boon Tiak

    1996-01-01

    The measurement of breakthrough and transit time through the central and southern canals of Lembaga Kemajuan Pertanian Muda (MADA) by using radiotracer technique is discussed An estimated of 1700 cusec water was released from Pelubang regulator through central canal. The water is then distributed through several regulators down stream and finally ended through the SCD1 and SCD1a secondary canals. Radiotracer 1-131 with the activity of 250 mCi and 500 mCi were injected at several identified injection points by using glass breaker technique. The measurement of breakthrough and transit time were observed respectively at several measurement station. Results of the study indicated that the time travel from Pelubang regulator to SCD1a secondary canal would take about 3 days during normal operation. Detail of breakthrough and transit time at every regulators and other measurement stations were also presented

  3. Removal of actinide elements from liquid scintillation cocktail wastes using liquid-liquid extraction and demulsification techniques

    International Nuclear Information System (INIS)

    Foltz, K.; Landsberger, S.; Srinivasan, B.; Vandegrift, G.F.

    1994-01-01

    For many years liquid scintillation cocktail (LSC) wastes have been generated and stored at Argonne National Laboratory (ANL). These wastes are stored in thousands of 10--20 m scintillation vials, many of which contain elements with Z > 88. Because storage space is limited, disposal of this waste is pressing. These wastes could be commercially incinerated if the radionuclides with Z>88 are reduced to sufficiently low levels. However, there is currently no deminimus level for these radionuclides, and separation techniques are still being tested. The University of Illinois is conducting experiments to separate radionuclides with Z > 88 from simulated LSC wastes by using liquid-liquid extraction (LLX) and demulsification techniques. The actinide elements are removed from the LSC by extraction into an aqueous phase after the cocktail has been demulsified. The aqueous and organic phases are separated and the organic phase, now free from radionuclides with Z > 88, can be sent to a commercial incineration facility. The aqueous phase may be treated and disposed of using existing techniques. The LLX separation techniques used solutions of sodium oxalate, aluminum nitrate, and tetrasodium EDTA at varying concentrations. These extractants were mixed with the simulated waste in a 1:1 volume ratio. Using 1.0M Na 4 EDTA salt solutions, decontamination ratios as high as 230 were achieved

  4. Extraction techniques for arsenic species in rice flour and their speciation by HPLC-ICP-MS.

    Science.gov (United States)

    Narukawa, Tomohiro; Suzuki, Toshihiro; Inagaki, Kazumi; Hioki, Akiharu

    2014-12-01

    The extraction of arsenic (As) species present in rice flour samples was investigated using different extracting solvents, and the concentration of each species was determined by HPLC-ICP-MS after heat-assisted extraction. The extraction efficiencies for total arsenic species and especially for arsenite [As(III)] and arsenate [As(V)] were investigated. As(III), As(V) and dimethylarsinic acid (DMAA) were found in the samples, and the concentration of DMAA did not vary with treatment conditions. However, the concentrations of extracted total arsenic and those of As(III) and As(V) depended on the extracting solvents. When an extracting solvent was highly acidic, the concentrations of extracted total arsenic were in good agreement with the total arsenic concentration determined by ICP-MS after microwave-assisted digestion, though a part of the As(V) was reduced to As(III) during the highly acidic extraction process. Extraction under neutral conditions increased the extracted As(V), but extracted total arsenic was decreased because a part of the As(III) could not be extracted. Optimum conditions for the extraction of As(III) and As(V) from rice flour samples are discussed to allow the accurate determinations of As(III), As(V) and DMAA in the rice flour samples. Heat block extraction techniques using 0.05 mol L(-1) HClO4 and silver-containing 0.15 mol L(-1) HNO3 were also developed. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Autoradiographic techniques to determine noble metal distribution in automotive catalyst substrates

    International Nuclear Information System (INIS)

    Lange, W.H.

    1976-01-01

    The distribution of noble metals in the ceramic substrates of automotive catalytic converter systems is important to the functional characteristics of the systems. A radiotracer technique involving microtomy of bead substrate samples and autoradiography using the resultant thin sections was developed to produce detailed images of the metal distributions. The method is particularly valuable to determine the distribution of one metal in the presence of another to aid in the development of more efficient systems

  6. The influence of molecular weight in radiotracers of inflamators processes

    International Nuclear Information System (INIS)

    Mesa Duennas, N.; Zayas Crespo, F.; Piedra Mazorra, J.; Diaz Barreto, M; Rodriguez Alfonso, M.E.; Perez Fuentes, A.

    2004-01-01

    Four 99mTc-radiopharmaceuticals (RPs) were compared as a radiotracers of inflammatory process. The RPs were divided in two groups according to their molecular weights and nature. One group included the human IgG and the ior t3 MoAb (anti-CD3), another included the Ciprofloxacine and the DMSA. The RPs were studied by different quality controls, and a biodistribution study in an aseptic inflammatory model made by steril Carragenin. The results obtained in the reduction of the immunoglobulins with 2-mercaptoethanol and sodium metabisulphite demonstrated that both reducing agents were equivalent, because the radiochemical purity obtained were similar and independent of the immunoglobulins. The biodistribution demonstrated a higher incorporation for the radiopharmaceuticals of high molecular weight, and the highest values were obtained with the 2-mercaptoethanol

  7. Quality control for measurement of soil samples containing 237Np and 241Am as radiotracer

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhang Caihong; Song Hailong; Ren Xiaona; Han Yuhu; Zhang Aiming; Chu Taiwei

    2003-01-01

    This paper reports quality control (QC) for the measurement of soil samples containing 237 Np and 241 Am as radiotracers in migration test of transuranic nuclides. All of the QC were done independently by the QA members of analytical work. It mainly included checking 5%-10% of the total analyzed samples; preparing blank samples, blind replicate sample and spiked samples used as quality control samples to check the quality of analytical work

  8. PET imaging of HSV1-tk mutants with acquired specificity toward pyrimidine- and acycloguanosine-based radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Likar, Yury; Dobrenkov, Konstantin; Olszewska, Malgorzata; Shenker, Larissa; Hricak, Hedvig; Ponomarev, Vladimir [Memorial Sloan-Kettering Cancer Center, Molecular Imaging Laboratory, Department of Radiology, New York, NY (United States); Cai, Shangde [Memorial Sloan-Kettering Cancer Center, Radiochemistry/Cyclotron Core Facility, New York, NY (United States)

    2009-08-15

    The aim of this study was to create an alternative mutant of the herpes simplex virus type 1 thymidine kinase (HSV1-tk) reporter gene with reduced phosphorylation capacity for acycloguanosine derivatives, but not pyrimidine-based compounds that will allow for successful PET imaging. A new mutant of HSV1-tk reporter gene, suitable for PET imaging using pyrimidine-based radiotracers, was developed. The HSV1-tk mutant contains an arginine-to-glutamine substitution at position 176 (HSV1-R176Qtk) of the nucleoside binding region of the enzyme. The mutant-gene product showed favorable enzymatic characteristics toward pyrimidine-based nucleosides, while exhibiting reduced activity with acycloguanosine derivatives. In order to enhance HSV1-R176Qtk reporter activity with pyrimidine-based radiotracers, we introduced the R176Q substitution into the more active HSV1-sr39tk mutant. U87 human glioma cells transduced with the HSV1-R176Qsr39tk double mutant reporter gene showed high {sup 3}H-FEAU pyrimidine nucleoside and low {sup 3}H-penciclovir acycloguanosine analog uptake in vitro. PET imaging also demonstrated high {sup 18}F-FEAU and low {sup 18}F-FHBG accumulation in HSV1-R176Qsr39tk+ xenografts. The feasibility of imaging two independent nucleoside-specific HSV1-tk mutants in the same animal with PET was demonstrated. Two opposite xenografts expressing the HSV1-R176Qsr39tk reporter gene and the previously described acycloguanosine-specific mutant of HSV1-tk, HSV1-A167Ysr39tk reporter gene, were imaged using a short-lived pyrimidine-based {sup 18}F-FEAU and an acycloguanosine-based {sup 18}F-FHBG radiotracer, respectively, administered on 2 consecutive days. We conclude that in combination with acycloguanosine-specific HSV1-A167Ysr39tk reporter gene, a HSV1-tk mutant containing the R176Q substitution could be used for PET imaging of two different cell populations or concurrent molecular biological processes in the same living subject. (orig.)

  9. Analysis and Comparison of the Antioxidant Component of Portulaca Oleracea Leaves Obtained by Different Solid-Liquid Extraction Techniques

    Science.gov (United States)

    Conte, Esterina

    2017-01-01

    Portulaca oleracea is a wild plant pest of orchards and gardens, but is also an edible vegetable rich in beneficial nutrients. It possesses many antioxidant properties due to the high content of vitamins, minerals, omega-3 essential fatty acids and other healthful compounds; therefore, the intake of purslane and/or its bioactive compounds could help to improve the health and function of the whole human organism. Accordingly, in this work it was analyzed and compared to the extractive capacity of the antioxidant component of purslane leaves obtained by solid-liquid extraction techniques such as: hot-maceration, maceration with ultrasound, rapid solid-liquid dynamic extraction using the Naviglio extractor, and a combination of two techniques (mix extraction). The chromatographic analysis by High Performance Liquid Chromatography (HPLC) of the methanolic extract of dried purslane leaves allowed the identification of various polyphenolic compounds for comparison with the standards. In addition, the properties of the different extracts were calculated on dry matter and the antioxidant properties of the total polyphenol components analyzed by the DPPH (2,2-diphenyl-1-picrylhydrazyl) assay. The results showed that mix extraction was the most efficient compared to other techniques. In fact, it obtained a quantity of polyphenols amounting to 237.8 mg Gallic Acid Equivalents (GAE)/100 g of fresh weight, while in other techniques, the range varied from 60–160 mg GAE/100 g fresh weight. In addition, a qualitative analysis by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) of the phenolic compounds present in the purslane leaves examined was carried out. The compounds were identified by comparison of their molecular weight, fragmentation pattern and retention time with those of standards, using the “Multiple Reaction Monitoring” mode (MRM). Therefore, this study allowed the re-evaluation of a little-known plant that possesses as its beneficial properties, a

  10. Technetium-99 behavior in the terrestrial environment. Field observations and radiotracer experiments

    International Nuclear Information System (INIS)

    Tagami, Keiko

    2003-01-01

    Obtaining data on 99 Tc in the rice paddy field environment is important because Tc is a redox sensitive element. The behavior of Tc is expected to be different under upland field and rice paddy field conditions since the redox conditions in the soil environment differ. However, most of the data on the nuclide behavior in soil were obtained under upland field conditions. To understand the global fallout 99 Tc distributions in soil samples collected in Japan, a simple and rapid separation method was developed in order to determine low-levels of 99 Tc in soil samples by an inductively coupled plasma mass spectrometry. Also, radiotracer experiments using soils under aerobic and anaerobic conditions were carried out to clarify the Tc behavior under paddy field conditions. The results of determination of global fallout 99 Tc in Japanese soils indicated that the radionuclide had been accumulating in rice paddy fields. The mechanisms can be explained by the immobilization of Tc in soil under anaerobic conditions. From the radiotracer experiments, it was clear that under waterlogged conditions, the highly mobile TcO 4 - in soil was readily changed to other immobilized forms, such as TcO 2 , TcS 2 and organically bound forms. To this immobilization, the microbial activity seemed to have an important role in Tc sorption reactions. When the soil, which was once kept in anaerobic conditions, was air-dried again and kept in aerobic conditions, the chemical forms of immobilized Tc did not change remarkably. Interestingly, the similar Tc behavior was observed in a real wet forest near the Chernobyl Reactor. (author)

  11. Cortisol production rates measured by liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Esteban, N.V.; Yergey, A.L.

    1990-01-01

    Cortisol production rates (FPRs) in physiologic and pathologic states in humans have been investigated over the past 30 years. However, there has been conflicting evidence concerning the validity of the currently accepted value of FPRs in humans (12 to 15 mg/m2/d) as determined by radiotracer methodology. The present study reviews previous methods proposed for the measurement of FPRs in humans and discusses the applications of the first method for the direct determination of 24-hour plasma FPRs during continuous administration of a stable isotope, using a thermospray high-pressure liquid chromatography-mass spectrometry technique. The technique is fast, sensitive, and, unlike gas chromatography-mass spectrometry methods, does not require derivatization, allowing on-line detection and quantification of plasma cortisol after a simple extraction procedure. The results of determination of plasma FPRs by stable tracer/mass spectrometry are directly in units of mass/time and, unlike radiotracer methods, are independent of any determination of volume of distribution or cortisol concentration. Our methodology offers distinct advantages over radiotracer techniques in simplicity and reliability since only single measurements of isotope ratios are required. The technique was validated in adrenalectomized patients. Circadian variations in daily FRPs were observed in normal volunteers, and, to date, results suggest a lower FRP in normal children and adults than previously believed. 88 references

  12. Nuclear techniques to investigate source and origin of groundwater pollutants and their flow path at Indian Rare Earths Ltd., Cochin, Kerala

    International Nuclear Information System (INIS)

    Tirumalesh, K.; Shivanna, K.; Noble, J.

    2007-01-01

    Hydrochemical, environmental isotope and injected radiotracer investigations were carried out in order to investigate the possible source of contaminants and their movement in groundwater at Indian Rare Earths (IRE) site. Water samples were collected from piezometers, dug wells and river in and around IRE site for measurement of physical parameters, chemistry and isotopes. Chemical results show high fluoride, nitrate, sulphate and phosphate concentrations in piezometers whereas dug wells and river samples are free from contamination. Isotope data indicate that the contaminated groundwaters are enriched in δ 2 H and δ 18 O compared to dug well and river samples. Radiotracer experiments were carried out using single-well and multi-well techniques (radiotracers: 82 Br and 3 H) for determining groundwater filtration velocity and flow direction, respectively. Groundwater filtration velocity was found to be about 1.3 cm/day and flow direction is from south to north. Based on the investigations it can be concluded that groundwater is getting contamination from southern part of IRE campus and the possible source for these contaminants could be the Fertilizer and Chemical of Travancore (FACT) industry. (author)

  13. Flavonoid extraction from Alpinia zerumbet (Pers.) Burtt et Smith leaves using different techniques and solvents

    International Nuclear Information System (INIS)

    Victorio, Cristiane P.; Lage, Celso Luiz S.; Kuster, Ricardo M.

    2009-01-01

    The current study aims to verify the best method for a rapid and efficient extraction of flavonoids from Alpinia zerumbet. Dried leaves were extracted using distillated water and ethanol 70% by extraction methods of shaking maceration, ultrasonic, microwave and stirring. By the application of TLC and reversed phase HPLC techniques the rutin and kempferol-3-O-glucuronide were detected. Ethanol 70% was more efficient for flavonoids extraction than water. No significant yielding variation was verified for ultrasonic, microwave and stirring methods using ethanol 70% (11 to 14%). The relative concentration of rutin and kempferol-3-O-glucuronide, respectively, was higher by ultrasonic (1.5 and 5.62 mg g -1 dried leaves, respectively) and by microwave (1.0 and 6.64 mg g -1 dried leaves) methods using ethanol. Rapid and simplified extraction proceeding optimize phyto chemical work and acquisition of secondary metabolites. (author)

  14. Flavonoid extraction from Alpinia zerumbet (Pers.) Burtt et Smith leaves using different techniques and solvents

    Energy Technology Data Exchange (ETDEWEB)

    Victorio, Cristiane P.; Lage, Celso Luiz S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Biofisica Carlos Chagas Filho. Lab. de Fisiologia Vegetal], e-mail: cris.pvictor@gmail.com; Kuster, Ricardo M. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Nucleo de Pesquisas de Produtos Naturais. Lab. de Fitoquimica

    2009-01-15

    The current study aims to verify the best method for a rapid and efficient extraction of flavonoids from Alpinia zerumbet. Dried leaves were extracted using distillated water and ethanol 70% by extraction methods of shaking maceration, ultrasonic, microwave and stirring. By the application of TLC and reversed phase HPLC techniques the rutin and kempferol-3-O-glucuronide were detected. Ethanol 70% was more efficient for flavonoids extraction than water. No significant yielding variation was verified for ultrasonic, microwave and stirring methods using ethanol 70% (11 to 14%). The relative concentration of rutin and kempferol-3-O-glucuronide, respectively, was higher by ultrasonic (1.5 and 5.62 mg g{sup -1} dried leaves, respectively) and by microwave (1.0 and 6.64 mg g{sup -1} dried leaves) methods using ethanol. Rapid and simplified extraction proceeding optimize phyto chemical work and acquisition of secondary metabolites. (author)

  15. Study of seepage losses from irrigation canals using radioactive tracer technique

    International Nuclear Information System (INIS)

    Ahmad, M.; Tariq, J.A.; Rashid, A.; Rafiq, M.; Iqbal, N.

    2004-06-01

    Pakistan has an intricate irrigation system comprising a huge network of canals. A significant fraction of water in irrigation canals is lost through seepage, which is further responsible for water logging and salinity in some areas. Government is considering lining of irrigation canals to overcome this twin menace. Due to involvement of huge costs, highly pervious sections where the seepage rate is appreciably high, are needed to be identified for planning and execution of remedial actions to eliminate or minimize seepage losses. The conventional methods of measuring seepage rate from canals are limited to 'ponding' and 'inflow-outflow' methods. The ponding method is usually restricted to small canals because of the costly bulkheads and water requirement, unaffordable closure of canal, non representation of the line source and variation in the rate of seepage loss with time due to the sealing effects of fine sediments settling out. Inaccurate measurement of discharge under field conditions and complication due to diversion do not favour the inflow-outflow method. It is believed that the analytical methods represent the most accurate and convenient means of determining seepage values using accurate insitu hydraulic conductivity of the subsoil determined by radiotracer, geometry of the canal and position of the groundwater. As a practical application, radiotracer experiments were carried out at Rakh branch canal near Sukhiki, District Hafizabad (Punjab) to determine groundwater filtration velocity by single well point dilution technique using Technetium-99m (sup 99m/Tc) radioactive tracer, Hydraulic conductivity (determined from filtration velocity and hydraulic gradient) and canal parameters were used in the parametric equation of parachute curve to estimate the seepage rate. The average seepage rate was 4.05 cubic meter per day per meter length of the canal (equivalent to 3.795 cusec per million square feet or 1.157 cumec per second per million square meter of

  16. A simple and efficient in vitro method for metabolism studies of radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang-Yoon; Choe, Yearn Seong E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Byung-Tae

    2001-05-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[{sup 18}F]fluoromethylbenzyl- ([{sup 18}F]1) and 4-[{sup 18}F]fluorobenzyl-piperidine moieties ([{sup 18}F]2) was studied and compared with the in vivo metabolism. Defluorination of the [{sup 18}F]1 mainly occurred to generate [{sup 18}F]fluoride ion both in vitro and in vivo. In contrast, the [{sup 18}F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[{sup 18}F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers.

  17. Phosphorus use efficiency of maize: an investigation using radiotracer phosphorus (32P)

    International Nuclear Information System (INIS)

    Meena, S.

    2017-01-01

    A better understanding on the nutrient uptake and utilization by plants is essential for developing better nutrient efficient cultivars suited for optimal production. Precise information on the PUE of crops and P dynamics can be obtained with the help of radiotracer technique. To study the phosphorus acquisition and phosphorus use efficiency of added sources in maize using 32 P, a pot culture experiment was conducted in a medium P soil (21.26 kg ha -1 ). The treatments were P as Single Superphosphate, Enriched FYM with Single Superphosphate (EFYM), DAP, Nutriseed pack (SSP), Nutriseed pack (DAP). The above treatments were applied along with phosphobacteria. Totally there were ten treatments replicated four times. Phosphorus sources were tagged with 32 P (obtained as 32 P in orthophosphoric medium from the Board of Radiation and Isotope Technology) and applied as per the treatments. Radioactive 32 P in the grain and stover sample was determined using Liquid Scintillation Counter (Perkin Elmer Tricarb 2810 R). Using the data, per cent phosphorus derived from fertilizer (%Pdff), per cent phosphorus derived from soil (%Pdfs), Phosphorus Use Efficiency (PUE) and A value were determined. Application of Phosphorus (SSP, DAP, enriched FYM with SSP, Nutriseed pack (SSP) and Nutriseed pack (DAP)) along with PB increased the per cent phosphorus derived from fertilizer (% Pdff), P uptake from fertilizer and PUE. The highest PUE of 25.38 was recorded in the treatment where enriched FYM with SSP was applied along with PB. (author)

  18. Study of wastewater treatment plants efficiency using radiotracers

    International Nuclear Information System (INIS)

    Dawi, W. D. A.

    2010-11-01

    This study was performed to investigate and diagnose hydrodynamic behavior of the Military Hospital wastewater treatment plant. The plant comprises two units of treatment, each of them has a separate system. The investigation was carried out using ''1''3''1I as a radiotracer. The concept of residence time distribution (RTD) was used to investigate the efficiency of the aeration tanks, secondary clarifiers and chlorine tanks. Preliminary treatment and modeling of the trace data was performed using two software package applied by the International Atomic Energy Agency (IAEA) namely 4621 counter version 1.0.0 and RTD software. Plug flow pattern (parallel flow) was detected in the aeration tank and secondary clarifier of system 1 in one unit, while no homogeneous mixing was observed in the chlorine tank. Short - circuiting (by - passing) was evident in the aeration tank of system 2 in the other unit, which significantly reduced the operating efficiency. The percentage of dead volumes clearly suggests that the aeration tank and secondary clarifier were well utilized in the whole plant. (Author)

  19. Novel process intensification techniques in solvent extraction. Contributed Paper IT-09

    International Nuclear Information System (INIS)

    Ghosh, S.K.

    2014-01-01

    Process intensification can be briefly described as any chemical engineering development that leads to substantially smaller, cleaner and more energy efficient technology. Process intensification in active nuclear material processing will offer additional benefit in terms of reduced containment volume. The intensification can be realized either by use of novel equipment or by novel operating techniques. Feasibility of hollow fiber (HF) modules and microchannels or microfluidic devices will be explained for their utilization in process intensification of solvent extraction operation in nuclear fuel cycle

  20. Uptake of heavy metals by the marine algae Padina gymnospora from Sepetiba Bay (RJ, Brazil) through radiotracers

    International Nuclear Information System (INIS)

    Magalhaes, V.F. de.

    1991-01-01

    The accumulation and the loss of 210 Pb, 51 Cr and 65 Zn by the alga Padina gymnospora is studied through radiotracer experiments. The evaluation of the alga as a bio indicator of these heavy metals pollution is presented. The use of this seaweed species to study the transfer of Pb, Cr, and Zn through the food chain is discussed. (M.A.C.)

  1. Development of new folate-based PET radiotracers: preclinical evaluation of 68Ga-DOTA-folate conjugates

    International Nuclear Information System (INIS)

    Fani, Melpomeni; Maecke, Helmut R.; Wang, Xuejuan; Nicolas, Guillaume; Medina, Christelle; Raynal, Isabelle; Port, Marc

    2011-01-01

    A number of 111 In- and 99m Tc-folate-based tracers have been evaluated as diagnostic agents for imaging folate receptor (FR)-positive tumours. A 68 Ga-folate-based radiopharmaceutical would be of great interest, combining the advantages of PET technology and the availability of 68 Ga from a generator. The aim of the study was to develop a new 68 Ga-folate-based PET radiotracer. Two new DOTA-folate conjugates, named P3026 and P1254, were synthesized using the 1,2-diaminoethane and 3-{2-[2-(3-amino-propoxy)-ethoxy]-ethoxy}-propylamine as a spacer, respectively. Both conjugates were labelled with 67/68 Ga. Binding affinity, internalization and externalization studies were performed using the FR-positive KB cell line. Biodistribution and PET/CT imaging studies were performed in nude mice, on a folate-deficient diet, bearing KB and HT1080 (FR-negative) tumours, concurrently. The new radiotracers were evaluated comparatively to the reference molecule 111 In-DTPA-folate ( 111 In-P3139). The K d values of 67/68 Ga-P3026 (4.65 ± 0.82 nM) and 67/68 Ga-P1254 (4.27 ± 0.42 nM) showed high affinity for the FR. The internalization rate followed the order 67/68 Ga-P3026 > 67/68 Ga-P1254 > 111 In-P3139, while almost double cellular retention was found for 67/68 Ga-P3026 and 67/68 Ga-P1254, compared to 111 In-P3139. The biodistribution data of 67/68 Ga-DOTA-folates showed high and receptor-mediated uptake on the FR-positive tumours and kidneys, with no significant differences compared to 111 In-P3139. PET/CT images, performed with 68 Ga-P3026, showed high uptake in the kidneys and clear visualization of the FR-positive tumours. The DOTA-folate conjugates can be efficiently labelled with 68 Ga in labelling yields and specific activities which allow clinical application. The characteristics of the 67/68 Ga-DOTA-folates are comparable to 111 In-DTPA-folate, which has already been used in clinical trials, showing that the new conjugates are promising candidates as PET radiotracers

  2. Radiotracer technique to quantify change in filtration velocity as a measure of dilution effect by artificial recharge in an arsenic infested aquifer at Ashoknagar, Habra - II block, 24 Paragana district, West Bengal

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2004-01-01

    Radioisotopes are frequently employed as tracers for various applications in industry, agricultural, medicine and hydrology. In hydrology, radiotracers are commonly applied to investigate several hydrological parameters of aquifers such as hydraulic conductivity, groundwater velocity and direction of flow etc. They impart valuable insight into the understanding of the hydrological systems. Application of radioisotopes in determination of groundwater flow velocity is now a well established technique. In this paper, groundwater filtration velocity was determined in an arsenic infested alluvium aquifer at Ashoknagar, Habra, West Bengal for determining the dilution effect due to arsenic free water. In some parts of West Bengal, generally shallow aquifers up to 80 m deep are contaminated due to geogenic arsenic. Researchers have different views about origin and mobility of arsenic in the groundwaters of West Bengal. For the removal of Arsenic from the groundwater various methods have been suggested and implemented such as ion-exchange, co-precipitation, adsorption, membrane separation and dilution etc. Dilution of the Arsenic concentration by artificial recharge of arsenic free water from the constructed pits in the contaminated aquifer is one such simple method. Efficacy of this method was studied by measuring filtration velocity in the contaminated aquifer at the Ashoknagar, Habra - II Block, North 24 Paragana district, West Bengal. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater. Point dilution technique in a single well was applied. Filtration velocity provided relevant information about the arsenic dilution in the groundwater by the artificial recharge and its value will be used as a model parameter. (author)

  3. [The anesthetic effects of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction].

    Science.gov (United States)

    Yang, Jieping; Liu, Wei; Gao, Qinghong

    2013-08-01

    To evaluate the anesthetic effects and safety of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction. A split-mouth study was designed. The bilateral impacted mandibular third molar of 32 participants were divided into Gow-Gates technique of inferior alveolar nerve block (Gow-Gates group) and conventional technique of inferior alveolar nerve block (conventional group) randomly with third molar extracted. The anesthetic effects and adverse events were recorded. All the participants completed the research. The anesthetic success rate was 96.9% in Gow-Gates group and 90.6% in conventional group with no statistical difference ( P= 0.317); but when comparing the anesthesia grade, Gow-Gates group had a 96.9% of grade A and B, and conventional group had a rate of 78.1% (P = 0.034). And the Gow-Gates group had a much lower withdrawn bleeding than conventional group (P = 0.025). Two groups had no hematoma. Gow-Gates technique had a reliable anesthesia effects and safety in impacted mandibular third molar extraction and could be chosen as a candidate for the conventional inferior alveolar nerve block.

  4. Abnormal gastrointestinal accumulation of radiotracer by gastric bleeding during 99mTc-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Chun, Kyung A.; Lee, Sang Woo; Lee, Jae Tae; Lee, Kyu Bo

    1998-01-01

    We present a case in which a patient with acute hemorrhagic gastritis demonstrated abnormal gastrointestinal accumulation of radiotracer during 99m Tc-methylene diphosphonate (MDP) skeletal scintigraphy. A hemorrhagic gastritis was subsequently demonstrated by endoscopy. The mechanism for the intestinal localization of 99m Tc-MDP in this patients is not clear, but we guess that the extravasated blood containing the radiopharmaceutical cannot recirculate and stays at the bleeding site, so we can see the intestinal activity

  5. The extraction of anthocyanins and proanthocyanidins from grapes to wine during fermentative maceration is affected by the enological technique.

    Science.gov (United States)

    Busse-Valverde, Naiara; Gómez-Plaza, Encarna; López-Roca, Jose M; Gil-Muñoz, Rocio; Bautista-Ortín, Ana B

    2011-05-25

    The effect of three enological techniques (low temperature prefermentative maceration, must freezing with dry ice, and the use of a maceration enzyme) on the extraction of anthocyanins and proanthocyanidins from must to wine during fermentative maceration was studied to determine the extent to which these compounds are extracted and to assess the changes on their qualitative composition due to enological technique applied. The results showed that the dry ice treatment led to wines with high color intensity and high anthocyanin content, the maximum rate of extraction being observed the first 6 days of fermentative maceration. Regarding the effect of the different techniques on the quantitative and qualitative composition of proanthocyanidins, only the dry ice treatment seemed to favor the extraction of high molecular weight skin proanthocyanidins. The low temperature prefermentative maceration treatment led to the highest concentration of proanthocyanidins at the moment of pressing; however, this treatment, contrary to expectations, led to wines with the highest content of seed-derived proanthocyanidins. The use of the maceration enzyme also increased the concentration of proanthocyanidins during all of the fermentative process, as compared to a control wine, although the increase was not only due to skin proanthocyanidins but also seed proanthocyanidins. We have demonstrated in this study that maceration enzymes also facilitate seed phenolic extraction.

  6. Extraction of minerals by underground leaching and other techniques. Dobycha poleznykh iskopaemykh podzemnym vyshchelachivaniyem i drugimi geotekhnologicheskimi metodami

    Energy Technology Data Exchange (ETDEWEB)

    Kalabin, A.I.

    1981-01-01

    Scientific and practical principles, criteria and classification of hydrogeologic methods of extraction of metals and other minerals from the lithosphere and hydrosphere are systematically outlined in this text, dealing with physical, physicochemical and bacterial-chemical techniques. Mechanism, kinetics, thermodynamics and hydrodynamics of the discussed methods are covered; scientific basis as well as techniques of physicogeologic and technological calculations, hydrodynamic and technological calculations. Role of underground atomic explosions in ore leaching is discussed. Experimental and industrial operations regarding uranium mining, copper, nickel, sulphur, rock and potassium salts, etc. is covered. Feasibility and potential of extracting minerals with new techniques is discussed, and it is demonstrated that this may bring about significant social consequences.

  7. Helium/solid powder O-ring leakage correlation experiments using a radiotracer

    International Nuclear Information System (INIS)

    Bild, R.W.; Leisher, W.B.; Weissman, S.H.; Seya, M.

    1984-01-01

    UO 2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

  8. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  9. Dynamic PET scanning and compartmental model analysis to determine cellular level radiotracer distribution in vivo

    International Nuclear Information System (INIS)

    Smith, G.T.; Hubner, K.F.; Goodman, M.M.; Stubbs, J.B.

    1992-01-01

    Positron emission tomography (PET) has been used to measure tissue radiotracer concentration in vivo. Radiochemical distribution can be determined with compartmental model analysis. A two compartment model describes the kinetics of N-13 ammonia ( 13 NH 3 ) in the myocardium. The model consists of a vascular space, Q 1 and a space for 13 NH 3 bound within the tissue, Q 2 . Differential equations for the model can be written: X(t) = AX(t) + BU( t), Y(t)= CX(t)+ DU(t) (1) where X(t) is a column vector [Q 1 (t); Q 2 (t)], U(t) is the arterial input activity measured from the left ventricular blood pool, and Y(t) is the measured tissue activity using PET. Matrices A, B, C, and D are dependent on physiological parameters describing the kinetics of 13 NH 3 in the myocardium. Estimated parameter matrices in Equation 1 have been validated in dog experiments by measuring myocardial perfusion with dynamic PET scanning and intravenous injection of 13 NH 3 . Tracer concentrations for each compartment can be calculated by direct integration of Equation 1. If the cellular level distribution of each compartment is known, the concentration of tracer within the intracellular and extracellular space can be determined. Applications of this type of modeling include parameter estimation for measurement of physiological processes, organ level dosimetry, and determination of cellular radiotracer distribution

  10. Novel in situ radiotracer methods for the direct and indirect study of chromate adsorption on alumina

    International Nuclear Information System (INIS)

    Gancs, L.; Nemeth, Z.; Horanyi, G.

    2002-01-01

    Radiotracer methods, particularly the radiotracer thin foil method, provide unique possibility of in situ monitoring of chromate adsorption on powdered adsorbents. Two different versions of the thin foil method can be distinguished. In the direct method, the species to be studied is labelled and the radiation measured gives direct information on the adsorption of this species. In the indirect method, a different labelled indicator species is added to the system and the adsorption of this species is followed and the adsorption of the species to be studied is determined based on analysis of the competitive adsorption processes. Both methods were used in the present study. In the in situ methods, the radiation measured consists of two main parts, one coming from the solution background, the other originating from the adsorption layer. In the case of the thin foil method using isotopes emitting soft β - radiation or low energy X-ray the solution background is governed and minimised by self-absorption of the radiation. In the direct study we applied an experimental methodology based on the energy selective measurement of the characteristic K α,β X-radiation emitted by the 51 Cr-labelled chromate species, whereas 35 S-labelled sulphate ions were used as the indicator species in the indirect study. (P.A.)

  11. Singular value decomposition based feature extraction technique for physiological signal analysis.

    Science.gov (United States)

    Chang, Cheng-Ding; Wang, Chien-Chih; Jiang, Bernard C

    2012-06-01

    Multiscale entropy (MSE) is one of the popular techniques to calculate and describe the complexity of the physiological signal. Many studies use this approach to detect changes in the physiological conditions in the human body. However, MSE results are easily affected by noise and trends, leading to incorrect estimation of MSE values. In this paper, singular value decomposition (SVD) is adopted to replace MSE to extract the features of physiological signals, and adopt the support vector machine (SVM) to classify the different physiological states. A test data set based on the PhysioNet website was used, and the classification results showed that using SVD to extract features of the physiological signal could attain a classification accuracy rate of 89.157%, which is higher than that using the MSE value (71.084%). The results show the proposed analysis procedure is effective and appropriate for distinguishing different physiological states. This promising result could be used as a reference for doctors in diagnosis of congestive heart failure (CHF) disease.

  12. Patented techniques for the extraction and isolation of secoisolari-ciresinol diglucoside from flaxseed.

    Science.gov (United States)

    Hosseinian, Farah S; Beta, Trust

    2009-01-01

    Plant lignans are phenolic compounds generally containing a dibenzylbutane skeleton. Secoisolariciresinol diglucoside (SDG) is the major lignan found in flaxseed. SDG is known to have antioxidant and anticancer properties. SDG can potentially be used as a natural antioxidant in foods thereby preventing further oxidation reactions and thus enhance the shelf life of foods. This article reviews the patents that are concerned with the extraction of SDG from flaxseed, the richest plant source of lignans. Most of the patented techniques for the extraction, isolation, and purification of SDG are conducted on defatted flaxseed and whole flaxseed. Flaxseed hull is potentially a good starting material. Furthermore, most methods use aliphatic alcohols (methanol, ethanol, isopropanol, butanol) to extract the complexed form of SDG. Combinations of these solvents are commonly used with water. Alkaline hydrolysis liberates SDG from its complexed form. SDG is enriched by a process involving either liquid-liquid partitioning or passing the aqueous phase through anion exchange resins or C18 resins. The SDG is recovered after evaporation of the water. Analytical HPLC coupled with mass spectrometry is performed to determine the quantity and purity of the extracted SDG.

  13. Comparative Evaluation of Different Extraction Techniques and Solvents for the Assay of Phytochemicals and Antioxidant Activity of Hashemi Rice Bran

    Directory of Open Access Journals (Sweden)

    Ali Ghasemzadeh

    2015-06-01

    Full Text Available Secondary metabolite contents (total phenolic, flavonoid, tocopherol, and tocotrienol and antioxidant activities of Hashemi rice bran extracts obtained by ultrasound-assisted and traditional solvent (ethanol and 50:50 (v/v ethanol-water extraction techniques were compared. Phenolic and, flavonoid compounds were identified using ultra-high performance liquid chromatography and method validation was performed. Significant differences (p < 0.05 were observed among the different extraction techniques upon comparison of phytochemical contents and antioxidant activities. The extracts obtained using the ethanol-water (50:50 v/v ultrasonic technique showed the highest amounts of total phenolics (288.40 mg/100 g dry material (DM, total flavonoids (156.20 mg/100 g DM, and total tocotrienols (56.23 mg/100 g DM, and the highest antioxidant activity (84.21% 1,1-diphenyl-2-picrylhydrazyl (DPPH, 65.27% β-carotene-linoleic bleaching and 82.20% nitric oxide scavenging activity. Secondary metabolite contents and antioxidant activities of the rice bran extracts varied depending of the extraction method used, and according to their effectiveness, these were organized in a decreasing order as follows: ethanol-water (50:50 v/v ultrasonic, ethanol-water (50:50 v/v maceration, ethanol ultrasonic and ethanol maceration methods. Ferulic, gallic and chlorogenic acids were the most abundant phenolic compounds in rice bran extracts. The phytochemical constituents of Hashemi rice bran and its antioxidant properties provides insights into its potential application to promote health.

  14. Comparison of yield, composition, and antioxidant activity of turmeric (Curcuma longa L.) extracts obtained using various techniques.

    Science.gov (United States)

    Braga, Mara E M; Leal, Patrícia F; Carvalho, João E; Meireles, M Angela A

    2003-10-22

    Turmeric extracts were obtained from two lots of raw material (M and S) using various techniques: hydrodistillation, low pressure solvent extraction, Soxhlet, and supercritical extraction using carbon dioxide and cosolvents. The solvents and cosolvents tested were ethanol, isopropyl alcohol, and their mixture in equal proportions. The composition of the extracts was determined by gas chromatography-flame ionization detection (GC-FID) and UV. The largest yield (27%, weight) was obtained in the Soxhlet extraction (turmeric (S), ethanol = 1:100); the lowest yield was detected in the hydrodistillation process (2.1%). For the supercritical extraction, the best cosolvent was a mixture of ethanol and isopropyl alcohol. Sixty percent of the light fraction of the extracts consisted of ar-turmerone, (Z)-gamma-atlantone, and (E)-gamma-atlantone, except for the Soxhlet extracts (1:100, ethanol), for which only ar-turmeronol and (Z)-alpha-atlantone were detected. The maximum amount of curcuminoids (8.43%) was obtained using Soxhlet extraction (ethanol/isopropyl alcohol). The Soxhlet and low pressure extract exhibited the strongest antioxidant activities.

  15. Gravitational wave extraction based on Cauchy-characteristic extraction and characteristic evolution

    Energy Technology Data Exchange (ETDEWEB)

    Babiuc, Maria [Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Szilagyi, Bela [Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); Hawke, Ian [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); School of Mathematics, University of Southampton, Southampton SO17 1BJ (United Kingdom); Zlochower, Yosef [Department of Physics and Astronomy, and Center for Gravitational Wave Astronomy, University of Texas at Brownsville, Brownsville, TX 78520 (United States)

    2005-12-07

    We implement a code to find the gravitational news at future null infinity by using data from a Cauchy code as boundary data for a characteristic code. This technique of Cauchy-characteristic extraction (CCE) allows for the unambiguous extraction of gravitational waves from numerical simulations. We first test the technique on non-radiative spacetimes: Minkowski spacetime, perturbations of Minkowski spacetime and static black hole spacetimes in various gauges. We show the convergence and limitations of the algorithm and illustrate its success in cases where other wave extraction methods fail. We further apply our techniques to a standard radiative test case for wave extraction, a linearized Teukolsky wave, presenting our results in comparison to the Zerilli technique, and we argue for the advantages of our method of extraction.

  16. Radiotracer method for residence time distribution study in multiphase flow system

    International Nuclear Information System (INIS)

    Sugiharto, S.; Su'ud, Z.; Kurniadi, R.; Wibisono, W.; Abidin, Z.

    2009-01-01

    [ 131 I] isotope in different chemical compounds have been injected into 24 in hydrocarbon transmission pipeline containing approximately 95% water, 3% crude oil, 2% gas and negligible solid material, respectively. The system is operated at the temperature around 70 deg. C enabling fluids flow is easier in the pipeline. The segment of measurement was chosen far from the junction point of the pipeline, therefore, it was reasonably to assume that the fluids in such multiphase system were separated distinctively. Expandable tubing of injector was used to ensure that the isotopes were injected at the proper place in the sense that [ 131 I]Na isotope was injected into water layer and iodo-benzene, [131] IC 6 H 5, was injected into crude oil regime. The radiotracer selection was based on the compatibility of radiotracer with each of fluids under investigation. [ 131 I]Na was used for measuring flow of water while iodo-benzene, [131] IC 6 H 5, was used for measuring flow of crude oil. Two scintillation detectors were used and they are put at the distances 80 and 100 m, respectively, from injection point. The residence time distribution data were utilized for calculation water and crude oil flows. Several injections were conducted in the experiments. Although the crude oil density is lighter than the density of water, the result of measurement shows that the water flow is faster than the crude oil flow. As the system is water-dominated, water may act as carrier and the movement of crude oil is slowed due to friction between crude oil with water and crude oil with gas at top layer. Above of all, this result was able to give answer on the question why crude oil always arrives behind water as it is checked at gathering station. In addition, the flow patterns of the water in the pipeline calculated by Reynolds number and predicted by simple tank-in-series model is turbulence in character.

  17. In vitro characterization of [18F]-florbetaben, an Aβ imaging radiotracer

    International Nuclear Information System (INIS)

    Fodero-Tavoletti, Michelle T.; Brockschnieder, Damian; Villemagne, Victor L.; Martin, Lucas; Connor, Andrea R.; Thiele, Andrea; Berndt, Mathias; McLean, Catriona A.; Krause, Sabine; Rowe, Christopher C.; Masters, Colin L.; Dinkelborg, Ludger; Dyrks, Thomas; Cappai, Roberto

    2012-01-01

    Purpose: Amyloid-β (Aβ) plaques are a major pathological hallmark of Alzheimer's disease (AD). The noninvasive detection of Aβ plaques may increase the accuracy of clinical diagnosis as well as monitor therapeutic interventions. While [ 11 C]-PiB is the most widely used Aβ positron emission tomography (PET) radiotracer, due to the short half-life of 11 C (20 min), its application is limited to centers with an on-site cyclotron and 11 C radiochemistry expertise. Therefore, novel [ 18 F] (half-life 110 min)-labeled Aβ PET tracers have been developed. We have demonstrated that [ 18 F]-florbetaben-PET can differentiate individuals diagnosed with AD from healthy elderly, Parkinson's disease and frontotemporal lobe dementia (FTLD-tau) patients. While [ 18 F]-florbetaben-PET retention matched the reported postmortem distribution of Aβ plaques, the nature of [ 18 F]-florbetaben binding to other pathological lesions comprising misfolded proteins needs further assessment. The objective of this study was to determine whether Florbetaben selectively binds to Aβ plaques in postmortem tissue specimens containing mixed pathological hallmarks (i.e., tau and α-synuclein aggregates). Method: Human AD, FTLD-tau and dementia with Lewy bodies (DLB) brain sections were analyzed by [ 18 F]-florbetaben autoradiography and [ 3 H]-florbetaben high-resolution emulsion autoradiography and [ 19 F]-florbetaben fluorescence microscopy. Results: Both autoradiographical analyses demonstrated that Florbetaben exclusively bound Aβ plaques in AD brain sections at low nanomolar concentrations. Furthermore, at concentrations thousand-folds higher than those during a PET scan, [ 19 F]-florbetaben did not bind to α-synuclein or tau aggregates in DLB and FTLD-tau brain sections, respectively. Detection of [ 19 F]-florbetaben staining by fluorescence microscopy in several AD brain regions demonstrated that Florbetaben identified Aβ plaques in all brain regions examined. Conclusion: This study

  18. Semi-automated lab-on-a-chip for dispensing GA-68 radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Weinberg, Irving [Weinberg Medical Physics LLC, Bethesda, MD (United States)

    2014-03-12

    We solved a technical problem that is hindering American progress in molecular medicine, and restricting US citizens from receiving optimal diagnostic care. Specifically, the project deals with a mother/daughter generator of positron-emitting radiotracers (Ge-68/Ga-68). These generator systems are approved in Europe but cannot be used in the USA, because of safety issues related to possible breakthrough of long-lived Ge-68 (mother) atoms. Europeans have demonstrated abilities of Ga-68-labeled radiotracers to image cancer foci with high sensitivity and specificity, and to use such methods to effectively plan therapy.The USA Food and Drug Administration (FDA) and Nuclear Regulatory Commission (NRC) have taken the position that every patient administration of Ga-68 should be preceded by an assay demonstrated that Ge-68 breakthrough is within acceptable limits. Breakthrough of parent elements is a sensitive subject at the FDA, as evidenced by the recent recall of Rb-82 generators due to inadvertent administrations of Sr-82. Commercially, there is no acceptable rapid method for assaying breakthrough of Ge-68 prior to each human administration. The gamma emissions of daughter Ga-68 have higher energies than the parent Ge-68, so that the shielding assays typically employed for Mo-99/Tc-99m generators cannot be applied to Ga-68 generators. The half-life of Ga-68 is 68 minutes, so that the standard 10-half-life delay (used to assess breakthrough in Sr-82/Rb-82 generators) cannot be applied to Ga-68 generators. As a result of the aforementioned regulatory requirements, Ga-68 generators are sold in the USA for animal use only.The American clinical community’s inability to utilize Ga-68 generators impairs abilities to treat patients domestically, and puts the USA at a disadvantage in developing exportable products. The proposed DOE project aimed to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences

  19. Stuffing the nail: A simple technique for the extraction of a broken femoral nail.

    Science.gov (United States)

    Lovell, Jane; Krishna, Damodaran; Gehr, Eugene

    2017-06-01

    The extraction of broken femoral nails can be a challenging procedure and surgeons should be familiar with many different techniques. This paper demonstrates a case study and new, simple and cost effective technique for the removal of broken cannulated femoral nails. Our technique uses two guide wires of variable diameter and had several key points of differentiation from previous methods. Firstly, stuffing the nail with guide wires of greater total diameter than the cannula; secondly, reversing the second guide wire and finally, bending the tips of the wires. These innovations allow the technique to be used for narrow cannulated nails, superior purchase along the length of the nail, easy wire insertion and limited soft tissue damage. Our technique for the removal of broken femoral nails is quick, effective, cheap and easy to replicate and can be used by any generalist orthopaedic surgeon with basic equipment.

  20. Dopamine D2 receptor radiotracers [11C](+)-PHNO and [3H]raclopride are indistinguishably inhibited by D2 agonists and antagonists ex vivo

    International Nuclear Information System (INIS)

    McCormick, Patrick N.; Kapur, Shitij; Seeman, Philip; Wilson, Alan A.

    2008-01-01

    Introduction: In vitro, the dopamine D2 receptor exists in two states, with high and low affinity for agonists. The high-affinity state is the physiologically active state thought to be involved in dopaminergic illnesses such as schizophrenia. The positron emission tomography radiotracer [ 11 C](+)-PHNO ([ 11 C](+)-4-propyl-3,4,4a,5,6,10b-hexahydro-2H-naphtho[1,2-b][1,4] oxazin-9-o l), being a D2 agonist, should selectively label the high-affinity state at tracer dose and therefore be more susceptible to competition by agonist as compared to the antagonist [ 3 H]raclopride, which binds to both affinity states. Methods: We tested this prediction using ex vivo dual-radiotracer experiments in conscious rats. D2 antagonists (haloperidol or clozapine), a partial agonist (aripiprazole), a full agonist [(-)-NPA] or the dopamine-releasing drug amphetamine (AMPH) were administered to rats prior to an intravenous coinjection of [ 11 C](+)-PHNO and [ 3 H]raclopride. Rats were sacrificed 60 min after radiotracer injection. Striatum, cerebellum and plasma samples were counted for 11 C and 3 H. The specific binding ratio {SBR, i.e., [%ID/g (striatum)-%ID/g (cerebellum)]/(%ID/g (cerebellum)} was used as the outcome measure. Results: In response to D2 antagonists, partial agonist or full agonist, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs responded indistinguishably in terms of both ED 50 and Hill slope (e.g., (-)-NPA ED 50 values are 0.027 and 0.023 mg/kg for [ 11 C](+)-PHNO and [ 3 H]raclopride, respectively). In response to AMPH challenge, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs were inhibited to the same degree. Conclusions: We have shown that the SBRs of [ 11 C](+)-PHNO- and [ 3 H]raclopride do not differ in their response to agonist challenge. These results do not support predictions of the in vivo binding behavior of a D2 agonist radiotracer and cast some doubt on the in vivo applicability of the D2 two-state model, as described by in vitro binding experiments

  1. Successful transjugular extraction of a lead in front of the anterior scalene muscle by using snare technique

    Directory of Open Access Journals (Sweden)

    Ayako Okada, MD

    2015-08-01

    Full Text Available The incidence of cardiovascular implantable electronic device infection is increasing. We report a case of and successful device removal in a 79-year-old man with implantable cardioverter-defibrillator infection. Right phrenic nerve paralysis was evident on chest radiography. The lead was in front of the anterior scalene muscle, close to the left phrenic nerve. Therefore, extraction carried a risk of bilateral phrenic nerve paralysis. The lead was successfully extracted from the right internal jugular vein by using the snare technique. No complications occurred, and the extraction was successful.

  2. Development of gamma emitting receptor binding radiotracers for imaging the brain and pancreas. Final technical progress report, March 1, 1988--May 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This document give paragraph synopses of results in research on brain and pancreas imaging, using radiotracers. General catagories of research included chemistry, pharmacology, imaging physics, and kinetic modeling. A list of publications is included

  3. Rapid extraction of PCDD/Fs from soil and fly ash samples. Pressurized fluid extraction (PFE) and microwave-assisted extraction (MAE)

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, P.; Fabrellas, B. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)

    2004-09-15

    The main reference extraction method in the analysis of polychlorinated dibenzop- dioxins and dibenzofurans (PCDD/Fs) is still the Soxhlet extraction. But it requires long extraction times (up to 24 hs), large volumes of hazardous organic solvents (100-300 ml) and its automation is limited. Pressurized Fluid Extraction (PFE) and Microwave-Assisted Extraction (MAE) are two relatively new extraction techniques that reduce the time and the volume of solvent required for extraction. However, very different PFE extraction conditions are found for the same enviromental matrices in the literature. MAE is not a extraction technique very applied for the analysis of PCDD/Fs yet, although it is used for the determination of other organic compounds, such as PCBs and PAHs. In this study, PFE and MAE extraction conditions were optimized to determine PCDDs y PCDFs in fly ash and soil/sediment samples. Conventional Soxhlet extraction with toluene was used to compare the extraction efficiency of both techniques.

  4. Estimative of dilution factor for radioactive liquid effluents employing the H-3 and Cs-137 radiotracers present as pollutant

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa; Santos, Adir Janete Godoy dos

    2011-01-01

    It was estimated the dilution factor for liquid effluents at the discharge points of the IPEN, Sao Paulo, Brazil, employing as radiotracers the radioisotope routinely liberated for the sewage of 'Cidade Universitaria Armando de Salles Oliveira' - CUASO 3 H and 137 Cs, not generating either monetary or environmental cost associated to the estimation. The 137 Cs was determined by gamma spectrometry and the 3 H was determined liquid phase scintillation. The results showed that the dilution factor varied according to the employed radiotracer in a crescent order of 3 H and 137 Cs according to the characteristics of each element. The average of dilution factors obtained at the first and second liberation day were 4.3 and 7.4 respectively for the 3 H and 6.2 and 13.9 for the 137 Cs. The ratio of dilution factors of calculated 3 H and 137 Cs were coherent with the ratio verified at the twelve hydrometers distributed by the IPEN campus. The dilution factors were estimated in operational and laboratory study, in a single controlled discharge of the TR1 tank

  5. Comparison of extraction and work up techniques for analysis of core and intact polar tetraether lipids from sedimentary environments

    NARCIS (Netherlands)

    Lengger, S.K.; Hopmans, E.C.; Sinninghe Damsté, J.S.; Schouten, S.

    2012-01-01

    Glycerol dibiphytanyl glycerol tetraether-based intact polar lipids (IPL GDGTs) are used as biomarkers for living Archaea and are analyzed utilizing a variety of extraction and quantification techniques. Most IPL GDGT studies have used a modified Bligh-Dyer extraction method, but it has been

  6. Effects of moisture content in cigar tobacco on nicotine extraction. Similarity between soxhlet and focused open-vessel microwave-assisted techniques.

    Science.gov (United States)

    Ng, Lay-Keow; Hupé, Michel

    2003-09-05

    The effects of tobacco moisture on nicotine yield were investigated in this study. Soxhlet and microwave-assisted techniques were used to extract nicotine from cigar fillers of varying moisture contents (5-20%), using a polar (methanol) and a non-polar (isooctane) solvent. The extracts were analyzed by a gas chromatograph equipped with a flame-ionization detector. For both extraction techniques, higher nicotine yields were consistently obtained with methanol than with isooctane from the same samples. Solubility of nicotine salts in methanol but not in isooctane is the major cause of this observation. Moreover, pronounced effects of the tobacco moisture content on extraction efficiency were observed with isooctane but not with methanol. For microwave assisted extraction (MAE) with isooctane, nicotine yield increased from 3 to 70% as the moisture level in tobacco was raised from 3 to 13%, and leveled off thereafter. Similar observations were made with Soxhlet extraction. While MAE results were rationalized by the known cell-rupture process, a mechanism based on the interaction between the solvents and the structural components of the plant cells has been proposed to account for the observations made with Soxhlet extraction.

  7. Radiotracer study to investigate the dilution and dispersion of sewage off Worli coast

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Pendharkar, A.S.; Agashe, S.M.; Kumar, U.S.; Kulkarni, U.P.; Mendhekar, G.N.; Navada, S.V.

    1998-01-01

    Radiotracer experiments were carried out off Worli Coast, Mumbai to study the dilution and dispersion of sewage from the proposed out fall at 3000 m and existing out fall at 500 m from the shore. Dilutions observed were 2.3 x 10 7 at 3.3 km from the injection point for the disposal at 3,000 m and 6.9 x 10 5 at 5 km for the disposal at 500 m. Dispersion coefficients obtained from two dimensional advection dispersion model for the experiment off 500 m are Dx 15-18 m 2 /s and Dy = 0.5-2 m 2 /s. (author)

  8. The uses of radiotracers in the life sciences

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, Thomas J [TRIUMF, Vancouver (Canada)

    2009-01-15

    Radionuclides have been used to follow physical, chemical and biological processes almost from the time of their discovery. Probably the application with the biggest impact has been in the medical field where radionuclides have been incorporated into biologically active molecules and used to diagnose a wide variety of diseases and to treat many disorders. Other uses in the life sciences, in general, are related to using a radioactive isotope as marker for an existing species such as nitrogen-13 in plant studies or copper-67 to track copper catalysts in phytoplankton. This review describes in general terms these uses as well as providing the reader with the background related to the physical properties of radioactive decay, the concepts associated with the production of radionuclides using reactors or accelerators and the fundamentals of imaging radioactivity. The advances in imaging technology in recent years has had a profound impact on the use of radionuclides in positron emission tomography and the coupling of other imaging modalities to provide very precise insights into human disease. The variety of uses for radiotracers in science is almost boundless dependent only upon ones imagination.

  9. The uses of radiotracers in the life sciences

    Science.gov (United States)

    Ruth, Thomas J.

    2009-01-01

    Radionuclides have been used to follow physical, chemical and biological processes almost from the time of their discovery. Probably the application with the biggest impact has been in the medical field where radionuclides have been incorporated into biologically active molecules and used to diagnose a wide variety of diseases and to treat many disorders. Other uses in the life sciences, in general, are related to using a radioactive isotope as marker for an existing species such as nitrogen-13 in plant studies or copper-67 to track copper catalysts in phytoplankton. This review describes in general terms these uses as well as providing the reader with the background related to the physical properties of radioactive decay, the concepts associated with the production of radionuclides using reactors or accelerators and the fundamentals of imaging radioactivity. The advances in imaging technology in recent years has had a profound impact on the use of radionuclides in positron emission tomography and the coupling of other imaging modalities to provide very precise insights into human disease. The variety of uses for radiotracers in science is almost boundless dependent only upon ones imagination.

  10. The uses of radiotracers in the life sciences

    International Nuclear Information System (INIS)

    Ruth, Thomas J

    2009-01-01

    Radionuclides have been used to follow physical, chemical and biological processes almost from the time of their discovery. Probably the application with the biggest impact has been in the medical field where radionuclides have been incorporated into biologically active molecules and used to diagnose a wide variety of diseases and to treat many disorders. Other uses in the life sciences, in general, are related to using a radioactive isotope as marker for an existing species such as nitrogen-13 in plant studies or copper-67 to track copper catalysts in phytoplankton. This review describes in general terms these uses as well as providing the reader with the background related to the physical properties of radioactive decay, the concepts associated with the production of radionuclides using reactors or accelerators and the fundamentals of imaging radioactivity. The advances in imaging technology in recent years has had a profound impact on the use of radionuclides in positron emission tomography and the coupling of other imaging modalities to provide very precise insights into human disease. The variety of uses for radiotracers in science is almost boundless dependent only upon ones imagination

  11. Abnormal gastrointestinal accumulation of radiotracer by gastric bleeding during {sup 99m}Tc-MDP bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kyung A.; Lee, Sang Woo; Lee, Jae Tae; Lee, Kyu Bo [College of Medicine, Kyungpook National Univ., Taegu (Korea, Republic of)

    1998-06-01

    We present a case in which a patient with acute hemorrhagic gastritis demonstrated abnormal gastrointestinal accumulation of radiotracer during {sup 99m}Tc-methylene diphosphonate (MDP) skeletal scintigraphy. A hemorrhagic gastritis was subsequently demonstrated by endoscopy. The mechanism for the intestinal localization of {sup 99m}Tc-MDP in this patients is not clear, but we guess that the extravasated blood containing the radiopharmaceutical cannot recirculate and stays at the bleeding site, so we can see the intestinal activity.

  12. Overview of radiotracer experiments for better understanding of wastewater and water treatment plants in Lima (Peru))

    International Nuclear Information System (INIS)

    Calvo, C.S.; Maghella, G.; Mamani, E.; Berne, P.; Brisset, P.; Leclerc, J.-P.

    2004-01-01

    The objectives of this paper are to present an overview of possible applications of the radiotracers for better understanding of water and waste water treatment plants. Numerous experiments have been carried out in different plants located in Lima. Four processes have been investigated: desanders, floculators, clarifiers and digesters. Depending on the studied process, the experimental results have been interpreted at different levels of complexity: from simple troubleshooting to the modelling of the flow behaviour inside the process. (author)

  13. Actinide extraction from ICPP sodium bearing waste with 0.75 M DHDECMP/TBP in Isopar L reg-sign

    International Nuclear Information System (INIS)

    Herbst, R.S.; Brewer, K.N.; Garn, T.G.; Law, J.D.; Rodriguez, A.M.; Tillotson, R.T.

    1996-01-01

    Recent process development efforts at the Idaho Chemical Processing Plant include examination of solvent extraction technologies for actinide partitioning from sodium bearing waste (SBW) solutions. The use of 0.75 M dihexyl-N, N-diethylcarbamoylmethylphosphonate (DHDECMP or simply CMP) and 1.0 M tri-n-butyl phosphate (TBP) diluted in Isopar L reg-sign was explored for actinide removal from simulated SBW solutions. Experimental evaluations included batch contacts in radiotracer tests with simulated sodium bearing waste solution to measure the extraction and recovery efficiency of the organic solvent. The radioactive isotopes utilized for this study included Pu-238, Pu-239, Am-241, U-233, Np-239, Zr-95, Tc-99m, and Hg-203. Extraction contacts of the organic solvent with the traced SBW stimulant, strip (back-extraction) contacts of the loaded organic solvent with either a 1-hydroxyethane-1, 1-diphosphonic acid (HEDPA) in nitric acid solution or an oxalic acid in nitric acid solution, and solvent wash contacts with sodium carbonate were performed

  14. Nuclear and radiation techniques - state of art and development trends; Techniki jadrowe i radiacyjne - stan obecny oraz kierunki rozwoju

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1995-12-31

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig.

  15. Charge transport and recombination in bulk heterojunction solar cells studied by the photoinduced charge extraction in linearly increasing voltage technique

    OpenAIRE

    Mozer, AJ; Sariciftci, NS; Osterbacka, R; Westerling, M; Juska, G; LUTSEN, Laurence; VANDERZANDE, Dirk

    2005-01-01

    Charge carrier mobility and recombination in a bulk heterojunction solar cell based on the mixture of poly[2-methoxy-5-(3,7-dimethyloctyloxy)-phenylene vinylene] (MDMO-PPV) and 1-(3-methoxycarbonyl)propyl-1-phenyl-(6,6)-C-61 (PCBM) has been studied using the novel technique of photoinduced charge carrier extraction in a linearly increasing voltage (Photo-CELIV). In this technique, charge carriers are photogenerated by a short laser flash, and extracted under a reverse bias voltage ramp after ...

  16. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    Science.gov (United States)

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  17. Robust breathing signal extraction from cone beam CT projections based on adaptive and global optimization techniques

    International Nuclear Information System (INIS)

    Chao, Ming; Yuan, Yading; Rosenzweig, Kenneth E; Lo, Yeh-Chi; Wei, Jie; Li, Tianfang

    2016-01-01

    We present a study of extracting respiratory signals from cone beam computed tomography (CBCT) projections within the framework of the Amsterdam Shroud (AS) technique. Acquired prior to the radiotherapy treatment, CBCT projections were preprocessed for contrast enhancement by converting the original intensity images to attenuation images with which the AS image was created. An adaptive robust z-normalization filtering was applied to further augment the weak oscillating structures locally. From the enhanced AS image, the respiratory signal was extracted using a two-step optimization approach to effectively reveal the large-scale regularity of the breathing signals. CBCT projection images from five patients acquired with the Varian Onboard Imager on the Clinac iX System Linear Accelerator (Varian Medical Systems, Palo Alto, CA) were employed to assess the proposed technique. Stable breathing signals can be reliably extracted using the proposed algorithm. Reference waveforms obtained using an air bellows belt (Philips Medical Systems, Cleveland, OH) were exported and compared to those with the AS based signals. The average errors for the enrolled patients between the estimated breath per minute (bpm) and the reference waveform bpm can be as low as  −0.07 with the standard deviation 1.58. The new algorithm outperformed the original AS technique for all patients by 8.5% to 30%. The impact of gantry rotation on the breathing signal was assessed with data acquired with a Quasar phantom (Modus Medical Devices Inc., London, Canada) and found to be minimal on the signal frequency. The new technique developed in this work will provide a practical solution to rendering markerless breathing signal using the CBCT projections for thoracic and abdominal patients. (paper)

  18. Digital lock-in techniques for adaptive power-line interference extraction.

    Science.gov (United States)

    Dobrev, Dobromir; Neycheva, Tatyana; Mudrov, Nikolay

    2008-07-01

    This paper presents a simple digital approach for adaptive power-line (PL) or other periodic interference extraction. By means of two digital square (or sine) wave mixers, the real and imaginary parts of the interference are found, and the interference waveform is synthesized and finally subtracted. The described technique can be implemented in an open-loop architecture where the interference is synthesized as a complex sinusoid or in a closed-loop architecture for automatic phase and gain control. The same approach can be used for removal of the fundamental frequency of the PL interference as well as its higher harmonics. It is suitable for real-time operation with popular low-cost microcontrollers.

  19. Hydroxyquinoline-calix[4]arene-conjugates as ligands for lanthanide complexes. Preparation, characterization, and extraction properties

    Energy Technology Data Exchange (ETDEWEB)

    Mansel, Alexander [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Reactive Transport; Jaeschke, A.; Kischel, M.; Kersting, B. [Leipzig Univ. (Germany). Inst. fuer Anorganische Chemie

    2017-06-01

    The synthesis of a calixarene-based N{sub 4}O{sub 4} donor ligand H{sub 6}L, in which two 8-hydroxyquinoline-2-carbaldehyde units are appended via hydrazone-carbonylmethoxy linkages in a 1,3-arrangement to the lower rim of tert-butyl-calix[4]arene and its coordination properties towards Eu{sup 3+} are described. Moreover, the ligand H{sub 6}L was found to extract Eu{sup 3+} and Tb{sup 3+} at pH 7-8 from aqueous solution, as established by radiotracing using the radionuclides {sup 160}Tb and {sup 152} Eu.

  20. Comparison of Amino Acid Positron Emission Tomographic Radiotracers for Molecular Imaging of Primary and Metastatic Brain Tumors

    Directory of Open Access Journals (Sweden)

    Csaba Juhász

    2014-08-01

    Full Text Available Positron emission tomography (PET is an imaging technology that can detect and characterize tumors based on their molecular and biochemical properties, such as altered glucose, nucleoside, or amino acid metabolism. PET plays a significant role in the diagnosis, prognostication, and treatment of various cancers, including brain tumors. In this article, we compare uptake mechanisms and the clinical performance of the amino acid PET radiotracers (L-[methyl-11C]methionine [MET], 18F-fluoroethyl-tyrosine [FET], 18F-fluoro-L- dihydroxy-phenylalanine [FDOPA], and 11C-alpha-methyl-L-tryptophan [AMT] most commonly used for brain tumor imaging. First, we discuss and compare the mechanisms of tumoral transport and accumulation, the basis of differential performance of these radioligands in clinical studies. Then we summarize studies that provided direct comparisons among these amino acid tracers and to clinically used 2-deoxy-2[18F]fluoro-D-glucose [FDG] PET imaging. We also discuss how tracer kinetic analysis can enhance the clinical information obtained from amino acid PET images. We discuss both similarities and differences in potential clinical value for each radioligand. This comparative review can guide which radiotracer to favor in future clinical trials aimed at defining the role of these molecular imaging modalities in the clinical management of brain tumor patients.

  1. Effect of process variables on the oil extraction from passion fruit seeds by conventional and non-conventional techniques - doi: 10.4025/actascitechnol.v36i1.15217

    Directory of Open Access Journals (Sweden)

    Ricardo Cardoso de Oliveira

    2014-01-01

    Full Text Available The effects of process variables on the oil extraction from passion fruit seeds by three techniques, ultrasound shaker, and soxhlet, and of environment-friendly solvents are evaluated. Ratio variables of seed weight, solvent volume (R, time of extraction (T, and type of solvent (S were evaluated. The significant variables for oil extraction from passion fruit seeds were R and S by ultrasound and shaker techniques and T for soxhlet extraction. Comparison of the three techniques showed that the soxhlet technique had the highest yield with 65% of total oil in the initial matrix.

  2. The Mellin transform technique for the extraction of the gluon density

    International Nuclear Information System (INIS)

    Graudenz, D.

    1995-06-01

    A new method is presented to determine the gluon density in the proton from jet production in deeply inelastic scattering. By using the technique of Mellin transforms not only for the solution of the scale evolution equation of the parton densities but also for the evaluation of scattering cross sections, the gluon density can be extracted in next-to-leading order QCD. The method described in this paper is, however, more general, and can be used in situations where a repeated fast numerical evaluation of scattering cross sections for varying parton distribution functions is required. (orig.)

  3. Evaluation of [11C]metergoline as a PET radiotracer for 5HTR in nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Hooker, J.M.; Hooker, J.M.; Kim, S.W.; Reibel, A.T.; Alexoff, D.; Xu, Y.; Shea, C.

    2010-04-20

    Metergoline, a serotonin receptor antagonist, was labeled with carbon-11 in order to evaluate its pharmacokinetics and distribution in non-human primates using positron emission tomography. [{sup 11}C]Metergoline had moderate brain uptake and exhibited heterogeneous specific binding, which was blocked by pretreatment with metergoline and altanserin throughout the cortex. Non-specific binding and insensitivity to changes in synaptic serotonin limit its potential as a PET radiotracer. However, the characterization of [{sup 11}C]metergoline pharmacokinetics and binding in the brain and peripheral organs using PET improves our understanding of metergoline drug pharmacology.

  4. Calcium carbonate scaling kinetics determined from radiotracer experiments with calcium-47

    International Nuclear Information System (INIS)

    Turner, C.W.; Smith, D.W.

    1998-01-01

    The deposition rate of calcium carbonate on a heat-transfer surface has been measured using a calcium-47 radiotracer and compared to the measured rate of thermal fouling. The crystalline phase of calcium carbonate that precipitates depends on the degree of supersaturation at the heat-transfer surface, with aragonite precipitating at higher supersaturations and calcite precipitating at lower supersaturations. Whereas the mass deposition rates were constant with time, the thermal fouling rates decreased throughout the course of each experiment as a result of densification of the deposit. It is proposed that the densification was driven by the temperature gradient across the deposit together with the retrograde solubility of calcium carbonate. The temperature dependence of the deposition rate yielded an activation energy of 79 ± 4 kJ/mol for the precipitation of calcium carbonate on a heat-transfer surface. (author)

  5. Extraction of intracellular protein from Chlorella pyrenoidosa using a combination of ethanol soaking, enzyme digest, ultrasonication and homogenization techniques.

    Science.gov (United States)

    Zhang, Ruilin; Chen, Jian; Zhang, Xuewu

    2018-01-01

    Due to the rigid cell wall of Chlorella species, it is still challenging to effectively extract significant amounts of protein. Mass methods were used for the extraction of intracellular protein from microalgae with biological, mechanical and chemical approaches. In this study, based on comparison of different extraction methods, a new protocol was established to maximize extract amounts of protein, which was involved in ethanol soaking, enzyme digest, ultrasonication and homogenization techniques. Under the optimized conditions, 72.4% of protein was extracted from the microalgae Chlorella pyrenoidosa, which should contribute to the research and development of Chlorella protein in functional food and medicine. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Amyloid PET imaging in Alzheimer's disease: a comparison of three radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Landau, S.M.; Jagust, W.J. [University of California, Berkeley, Helen Wills Neuroscience Institute, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Life Sciences Division, Berkeley, CA (United States); Thomas, B.A. [University College London, Institute of Nuclear Medicine, London (United Kingdom); Thurfjell, L. [GE Healthcare, Uppsala (Sweden); Schmidt, M. [Janssen Pharmaceutica, NV, Beerse (Belgium); Margolin, R. [Janssen Alzheimer Immunotherapy, South San Francisco, CA (United States); Mintun, M.; Pontecorvo, M. [Avid Radiopharmaceuticals, Inc., Philadelphia, PA (United States); Baker, S.L. [Lawrence Berkeley National Laboratory, Life Sciences Division, Berkeley, CA (United States); Collaboration: The Alzheimer' s Disease Neuroimaging Initiative

    2014-07-15

    The increasing use of amyloid PET in Alzheimer's disease research and clinical trials has motivated efforts to standardize methodology. We compared retention of the {sup 11}C radiotracer Pittsburgh Compound B (PiB) and that of two {sup 18}F amyloid radiotracers (florbetapir and flutemetamol) using two study populations. We also examined the feasibility of converting between tracer-specific measures, using PiB as the common link between the two {sup 18}F tracers. One group of 40 subjects underwent PiB and flutemetamol imaging sessions and a separate group of 32 subjects underwent PiB and florbetapir imaging sessions. We compared cortical and white matter retention for each {sup 18}F tracer relative to that of PiB, as well as retention in several reference regions and image analysis methods. Correlations between tracer pairs were used to convert tracer-specific threshold values for amyloid positivity between tracers. Cortical retention for each pair of tracers was strongly correlated regardless of reference region (PiB-flutemetamol, ρ = 0.84-0.99; PiB-florbetapir, ρ = 0.83-0.97) and analysis method (ρ = 0.90-0.99). Compared to PiB, flutemetamol had higher white matter retention, while florbetapir had lower cortical retention. Two previously established independent thresholds for amyloid positivity were highly consistent when values were converted between tracer pairs. Despite differing white and grey matter retention characteristics, cortical retention for each {sup 18}F tracer was highly correlated with that of PiB, enabling conversion of thresholds across tracer measurement scales with a high level of internal consistency. Standardization of analysis methods and measurement scales may facilitate the comparison of amyloid PET data obtained using different tracers. (orig.)

  7. DNA Extraction Techniques for Use in Education

    Science.gov (United States)

    Hearn, R. P.; Arblaster, K. E.

    2010-01-01

    DNA extraction provides a hands-on introduction to DNA and enables students to gain real life experience and practical knowledge of DNA. Students gain a sense of ownership and are more enthusiastic when they use their own DNA. A cost effective, simple protocol for DNA extraction and visualization was devised. Buccal mucosal epithelia provide a…

  8. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  9. Robust real-time extraction of respiratory signals from PET list-mode data.

    Science.gov (United States)

    Salomon, Andre; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas

    2018-05-01

    Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions' detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting ("binning") of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signalsdirectly from the acquired PET data simplifies the clinical workflow as it avoids to handle additional signal measurement equipment. We introduce a new data-driven method "Combined Local Motion Detection" (CLMD). It uses the Time-of-Flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using 7 measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4s in total on a standard multi-core CPU

  10. Robust real-time extraction of respiratory signals from PET list-mode data

    Science.gov (United States)

    Salomon, André; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas

    2018-06-01

    Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions’ detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting (‘binning’) of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signals directly from the acquired PET data simplifies the clinical workflow as it avoids handling additional signal measurement equipment. We introduce a new data-driven method ‘combined local motion detection’ (CLMD). It uses the time-of-flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using seven measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4 s in total on a standard

  11. Low-voltage electrically-enhanced microextraction as a novel technique for simultaneous extraction of acidic and basic drugs from biological fluids.

    Science.gov (United States)

    Seidi, Shahram; Yamini, Yadollah; Rezazadeh, Maryam; Esrafili, Ali

    2012-06-22

    In the present work, for the first time a new set-up was presented for simultaneous extraction of acidic and basic drugs using a recent novel electrically-enhanced microextraction technique, termed electromembrane extraction at low voltages followed by high performance liquid chromatography with ultraviolet detection. Nalmefene (NAL) as a basic drug and diclofenac (DIC) as an acidic drug were extracted from 24 mL aqueous sample solutions at neutral pH into 10 μL of each acidified (HCl 50 mM) and basic (NaOH 50 mM) acceptor solution, respectively. Supported liquid membranes including 2-nitrophenyl octyl ether containing 5% di-(2-ethylhexyl) phosphate and 1-octanol were used to ensure efficient extraction of NAL and DIC, respectively. Low voltage of 40 V was applied over the SLMs during 14 min extraction time. The influences of fundamental parameters affecting the transport of target drugs were optimized using experimental design. Under optimal conditions, NAL and DIC were extracted with extraction recoveries of 12.5 and 14.6, respectively, which corresponded to preconcentration factors of 300 and 350, respectively. The proposed technique provided good linearity with correlation coefficient values higher than 0.9956 over a concentration range of 8-500 μg L⁻¹ and 12-500 μg L⁻¹ for NAL and DIC, respectively. Limits of detection and quantifications, and intra-day precisions (n=3) were less than 4 μg L⁻¹, 12 μg L⁻¹, and 10.1%, respectively. Extraction and determination of NAL and DIC in human urine samples were successfully performed. In light of the data obtained in the present work, this new set-up for EME with low voltages has a future potential as a simple, selective, and fast sample preparation technique for simultaneous extraction and determination of acidic and basic drugs in different complicated matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. A radiotracer for In vivo studies of acetylcholinesterase: p-[{sup 18}F]fluorodonepezil

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S. Y.; Choi, Y. S.; Choi, Y.; Kim, S. E.; Lee, K. H.; Kim, B. T. [Samsung Medical Center, Seoul (Korea, Republic of); Lee, J. W. [Seoul National Univ., Seoul (Korea, Republic of)

    1999-05-01

    Alzheimer's disease (AD) is one of senile dementia caused by lack of acetylcholine in central nervous system, and in vivo studies of acetylcholinesterase (AChE) have been carried out using many radiolabeled AChE inhibitors (donepezil, tacrine, physostigmine, CP-126,998, etc). Donepezil, a FDA approved drug for AD is now in clinical use. Therefore, we synthesized and evaluated p-[{sup 18}F]fluorodonepezil in mice. Biodistribution studies demonstrated that p-[{sup 18}F]fluorodonepezil binds non-specifically in vivo and does not suffer from metabolism in mouse brain. This study suggests that radioligands with higher binding affinity may be required to visualize AChE in vivo and further studies are needed to develop better radiotracers.

  13. A magnet built on bronchoscopic suction for extraction of tracheobronchial headscarf pins: a novel technique and review of a tertiary centre experience†

    Science.gov (United States)

    Elsayed, Hany H.; Mostafa, Ahmed M.; Soliman, Saleh; El-Bawab, Hatem Y.; Moharram, Adel A.; El-Nori, Ahmed A.

    2016-01-01

    OBJECTIVES Airway metal pins are one of the most commonly inhaled foreign bodies in Eastern societies in young females wearing headscarves. We innovated a modified bronchoscopic technique to extract tracheobronchial headscarf pins by the insertion of a magnet to allow an easy and non-traumatic extraction of the pins. The aim of this study was to assess the feasibility and safety of our new technique and compare it with our large previous experience with the classic bronchoscopic method of extraction of tracheobronchial headscarf pins. METHODS We performed a study comparing our retrospective experience of classic bronchoscopic extraction from February 2004 to January 2014 and prospective experience with our modified technique using the magnet from January 2014 to June 2015. An institutional review board and new device approval were obtained. RESULTS Three hundred and twenty-six procedures on 315 patients were performed during our initial 10-year experience. Of them, 304 patients were females. The median age of our group was 13 (0–62). The median time from inhalation to procedure was 1 day (0–1022). After introducing our modified new technique using the magnet, 20 procedures were performed. Nineteen were females. The median time of the procedure and the need to forcefully bend the pin for extraction were in favour of the new technique in comparison with our classic approach (2 vs 6 min; P magnets was safer and simpler in comparison with our large experience with the classic approach. We advise the use of this device (or concept) in selected patients in centres dealing with this problem. PMID:26850113

  14. Plutonium and americium extraction studies with bifunctional organophosphorus extractants

    International Nuclear Information System (INIS)

    Navratil, J.D.

    1985-01-01

    Neutral bifunctional organophosphorus extractants, such as octylphenyl-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) and dihexyl-N,N-diethylcarbamoylmethylphosphonate (CMP), are under study at the Rocky Flats Plant (RFP) to remove plutonium and americium from the 7M nitric acid waste. These compounds extract trivalent actinides from strong nitric acid, a property which distinguishes them from monofunctional organiphosphorus reagents. Furthermore, the reagents extract hydroytic plutonium (IV) polymer which is present in the acid waste stream. The compounds extract trivalent actinides with a 3:1 stoichiometry, whereas tetra- and hexavalent actinides extract with a stoichiometry of 2:1. Preliminary studies indicate that the extracted plutonium polymer complex contains one to two molecules of CMP per plutonium ion and the plutonium(IV) maintains a polymeric structure. Recent studies by Horwitz and co-workers conclude that the CMPO and CMP reagents behave as monodentate ligands. At RFP, three techniques are being tested for using CMP and CMPO to remove plutonium and americium from nitric acid waste streams. The different techniques are liquid-liquid extraction, extraction chromatography, and solid-supported liquid membranes. Recent tests of the last two techniques will be briefly described. In all the experiments, CMP was an 84% pure material from Bray Oil Co. and CMPO was 98% pure from M and T Chemicals

  15. A solvent extraction technique for the isotopic measurement of dissolved copper in seawater

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Claire M., E-mail: claire.thompson@anu.edu.au; Ellwood, Michael J., E-mail: michael.ellwood@anu.edu.au; Wille, Martin, E-mail: martin.wille@uni-tuebingen.de

    2013-05-02

    Graphical abstract: -- Highlights: •A new sample preparation method for seawater copper isotopic analysis (δ{sup 65}Cu). •Solvent-extraction was used to pre-concentrate metals from seawater samples. •Anion-exchange was used to purify copper from the metal-rich extract. •δ{sup 65}Cu was measured in the north Tasman Sea. •Seawater δ{sup 65}Cu may be linked to marine biological activity. -- Abstract: Stable copper (Cu) isotope geochemistry provides a new perspective for investigating and understanding Cu speciation and biogeochemical Cu cycling in seawater. In this work, sample preparation for isotopic analysis employed solvent-extraction with amino pyrollidine dithiocarbamate/diethyl dithiocarbamate (APDC/DDC), coupled with a nitric acid back-extraction, to concentrate Cu from seawater. This was followed by Cu-purification using anion-exchange. This straightforward technique is high yielding and fractionation free for Cu and allows precise measurement of the seawater Cu isotopic composition using multi-collector inductively coupled plasma mass-spectrometry. A deep-sea profile measured in the oligotrophic north Tasman Sea shows fractionation in the Cu isotopic signature in the photic zone but is relatively homogenised at depth. A minima in the Cu isotopic profile correlates with the chlorophyll a maximum at the site. These results indicate that a range of processes are likely to fractionate stable Cu isotopes in seawater.

  16. Improving face image extraction by using deep learning technique

    Science.gov (United States)

    Xue, Zhiyun; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.

    2016-03-01

    The National Library of Medicine (NLM) has made a collection of over a 1.2 million research articles containing 3.2 million figure images searchable using the Open-iSM multimodal (text+image) search engine. Many images are visible light photographs, some of which are images containing faces ("face images"). Some of these face images are acquired in unconstrained settings, while others are studio photos. To extract the face regions in the images, we first applied one of the most widely-used face detectors, a pre-trained Viola-Jones detector implemented in Matlab and OpenCV. The Viola-Jones detector was trained for unconstrained face image detection, but the results for the NLM database included many false positives, which resulted in a very low precision. To improve this performance, we applied a deep learning technique, which reduced the number of false positives and as a result, the detection precision was improved significantly. (For example, the classification accuracy for identifying whether the face regions output by this Viola- Jones detector are true positives or not in a test set is about 96%.) By combining these two techniques (Viola-Jones and deep learning) we were able to increase the system precision considerably, while avoiding the need to manually construct a large training set by manual delineation of the face regions.

  17. A 3D edge detection technique for surface extraction in computed tomography for dimensional metrology applications

    DEFF Research Database (Denmark)

    Yagüe-Fabra, J.A.; Ontiveros, S.; Jiménez, R.

    2013-01-01

    Many factors influence the measurement uncertainty when using computed tomography for dimensional metrology applications. One of the most critical steps is the surface extraction phase. An incorrect determination of the surface may significantly increase the measurement uncertainty. This paper...... presents an edge detection method for the surface extraction based on a 3D Canny algorithm with sub-voxel resolution. The advantages of this method are shown in comparison with the most commonly used technique nowadays, i.e. the local threshold definition. Both methods are applied to reference standards...

  18. Extraction methods and test techniques for detection of vegetable proteins in meat products. I. Qualitative detection of soya derivatives.

    Science.gov (United States)

    Hyslop, N S

    1976-06-01

    Extracts of 3 soya bean preparations, used commercially in certain countries to replace part of the meat in popular meat products, were made by treatment with (i) sodium dodecyl sulphate, (ii) Triton-X100 or (iii) n-Butanol. Similar extracts were made from beef and pork. All extracts were examined by electrophoretic and immunological techniques. Stained polyacrylamide gels revealed distinctive protein bands after electrophoresis. The migration rates of corresponding bands differed between beef and pork extracts. However, the migration rates of vegetable bands revealed certain similarities, but differed very greatly from those of animal origin. Characteristic fast-migrating S-bands were distinguishable only in extracts of vegetable protein. Immunodiffusion tests, using antisera produced in rabbits against each extract, revealed varying degrees of similarity between extracts of vegetable origin, but the antisera were specific for either vegetable or animal protein.

  19. Evaluating chemical extraction techniques for the determination of uranium oxidation state in reduced aquifer sediments

    Science.gov (United States)

    Stoliker, Deborah L.; Campbell, Kate M.; Fox, Patricia M.; Singer, David M.; Kaviani, Nazila; Carey, Minna; Peck, Nicole E.; Barger, John R.; Kent, Douglas B.; Davis, James A.

    2013-01-01

    Extraction techniques utilizing high pH and (bi)carbonate concentrations were evaluated for their efficacy in determining the oxidation state of uranium (U) in reduced sediments collected from Rifle, CO. Differences in dissolved concentrations between oxic and anoxic extractions have been proposed as a means to quantify the U(VI) and U(IV) content of sediments. An additional step was added to anoxic extractions using a strong anion exchange resin to separate dissolved U(IV) and U(VI). X-ray spectroscopy showed that U(IV) in the sediments was present as polymerized precipitates similar to uraninite and/or less ordered U(IV), referred to as non-uraninite U(IV) species associated with biomass (NUSAB). Extractions of sediment containing both uraninite and NUSAB displayed higher dissolved uranium concentrations under oxic than anoxic conditions while extractions of sediment dominated by NUSAB resulted in identical dissolved U concentrations. Dissolved U(IV) was rapidly oxidized under anoxic conditions in all experiments. Uraninite reacted minimally under anoxic conditions but thermodynamic calculations show that its propensity to oxidize is sensitive to solution chemistry and sediment mineralogy. A universal method for quantification of U(IV) and U(VI) in sediments has not yet been developed but the chemical extractions, when combined with solid-phase characterization, have a narrow range of applicability for sediments without U(VI).

  20. Determination of cobalt-60 in seawater by solvent extraction with pyrrolidinedithiocarbamic acid

    International Nuclear Information System (INIS)

    Tseng, C.L.; Lo, J.M.

    1978-01-01

    Cobalt-60 was extracted from a large volume of seawater and concentrated in a small volume of organic solution of pyrrolidinedithiocarbamic acid (HPDC) in chloroform. All foreign nuclides in the organic phase were stripped completely with 12N HCl and 2N HNO 3 successively. By this procedure, a chemically pure Co-60 chelate, 60 Co(PDC) 3 , in chloroform was obtained. The recovery of Co-60 activity was found to average 99%. Cobalt-60 in seawater can thus be simply, rapidly and accurately determined by direct NaI(Tl) scintillation counting. The time for a single analysis, for example, exclusive of the counting operation, is about 40 min. The effects of various foreign nuclides on the extraction of Co-60 were examined by the use of 42 radiotracers and the results are tabulated. The nuclides Ag + , Mn 2+ , Ni 2+ , Cu 2+ , Zn 2+ , Cd 2+ , Pb 2+ , Hg 2+ , Fe 3+ , Ga 3+ , In 3+ , As 3+ , Sn 4+ , and Cr 6+ were extracted almost completely into chloroform with cobalt as the pyrrolidinedithiocarbamates. The extraction yield of Sb 3+ was close to 90%. Appreciable fractions of Cs + , Ba 2+ , Cr 3+ , Zr 4+ and Np 5+ were also found in the organic phase. (T.I.)

  1. Using text mining techniques to extract phenotypic information from the PhenoCHF corpus.

    Science.gov (United States)

    Alnazzawi, Noha; Thompson, Paul; Batista-Navarro, Riza; Ananiadou, Sophia

    2015-01-01

    Phenotypic information locked away in unstructured narrative text presents significant barriers to information accessibility, both for clinical practitioners and for computerised applications used for clinical research purposes. Text mining (TM) techniques have previously been applied successfully to extract different types of information from text in the biomedical domain. They have the potential to be extended to allow the extraction of information relating to phenotypes from free text. To stimulate the development of TM systems that are able to extract phenotypic information from text, we have created a new corpus (PhenoCHF) that is annotated by domain experts with several types of phenotypic information relating to congestive heart failure. To ensure that systems developed using the corpus are robust to multiple text types, it integrates text from heterogeneous sources, i.e., electronic health records (EHRs) and scientific articles from the literature. We have developed several different phenotype extraction methods to demonstrate the utility of the corpus, and tested these methods on a further corpus, i.e., ShARe/CLEF 2013. Evaluation of our automated methods showed that PhenoCHF can facilitate the training of reliable phenotype extraction systems, which are robust to variations in text type. These results have been reinforced by evaluating our trained systems on the ShARe/CLEF corpus, which contains clinical records of various types. Like other studies within the biomedical domain, we found that solutions based on conditional random fields produced the best results, when coupled with a rich feature set. PhenoCHF is the first annotated corpus aimed at encoding detailed phenotypic information. The unique heterogeneous composition of the corpus has been shown to be advantageous in the training of systems that can accurately extract phenotypic information from a range of different text types. Although the scope of our annotation is currently limited to a single

  2. Radiotracer studies with abomasum

    International Nuclear Information System (INIS)

    Angelo, I.A.

    1979-01-01

    14 C-amino acid incorporation into the abomasal tissue proteins was studied in the presence of milk constituents and tissue extracts. Addition of either casein, α-lactalbumin or fresh milk in the assay system inhibited the incorporation phenomenon. Milk whey, boiled milk or tissue extracts from liver and kidney on the other hand, distinctly stimulated incorporation of amino acids. A 14 C-labelled prorennin preparation was obtained in vitro from kid abomassum. Sephadex G-100 gel filtration resolved it into two components. The first protein positive component was associated with radioactivity. (orig.) 891 AJ/orig. 892 MKO [de

  3. Use of low cost dead biomasses in the removal of heavy metal toxic/radiotoxic ions from aqueous wastes- a radiotracer study

    International Nuclear Information System (INIS)

    Mishra, Shuddhodan P.

    2005-01-01

    In an environmental context, accelerating pollution by toxic metal ions, metalloids, radionuclides and organometal (loid)s has provided the impetus for the research to look into the biotechnological potential of utilizing several low cost dead biomasses/agricultural byproducts to replace existing expensive technologies. Unlike organic pollutants which are biodegradable, these metallic contaminants tend to persist rather indefinitely in the environment, and are eventually accumulated through the food chain thus posing a serious threat to plants, animal and man. The use of radiotracer technique by several workers and ourselves in the study of adsorption uptake or ions (cations and anions) from aqueous solutions by metals/metals oxide surfaces at micro down to tracer level concentrations had been quite rewarding. In continuation of this work the present studies were directed to assess the uptake behaviour of abundantly available low cost dead biomasses [e.g. Rice hulls (oryza sativa L),] Mango (mangifera indica) and Neem (azadirachta indica)barks] towards some heavy metal (Hg 2+ , Cd 2+ , Cr 2+ , Zn 2+ and Ce 3+ ) toxic and radiotoxic (Sr 2+ and Cs l+ )ions from aqueous solutions at low ionic concentrations (10 -2 -10 -8 mol dm -3 ). In all these studies the adsorptive solution was labeled by a suitable radiotracer of the metal ion and the uptake of ions by the three biosorbents was assessed through monitoring of the decrease in radioactivity of the bulk. A parametric study through change of temperature, pH and addition of other co-ions/complexing agents has helped in deducing the thermodynamic parameters and mechanism of the uptake of the ions. The extent of removal of metal ions by these dead biomasses is quite high in most cases and the nature of the uptake appears to be exchange type. These findings show that the agricultural byproducts (dead biomasses) can be utilized in the development of waste water treatment technology for removal of heavy metal toxic and

  4. Evaluation of vacuum microwave-assisted extraction technique for the extraction of antioxidants from plant samples.

    Science.gov (United States)

    Xiao, Xiao-Hua; Wang, Jun-Xia; Wang, Gang; Wang, Jia-Yue; Li, Gong-Ke

    2009-12-18

    In the present work, vacuum microwave-assisted extraction (VMAE) was to perform microwave-assisted extraction in vacuum. Two well-known antioxidants, vitamin C from guava and green pepper, and vitamin E (alpha-tocopherol and gamma-tocopherol) from soybean and tea leaves, which were easy to be oxidized, were chosen as representative target compounds for the evaluation of VMAE. The extraction yields of vitamin C, alpha-tocopherol and gamma-tocopherol in VMAE and those in MAE performed in atmosphere (air-MAE) were compared and the effects of extraction time, extraction temperature and sample matrix were studied. Moreover, the effects of the oxygen and subpressure invacuo were also discussed via performed MAE in N(2) atmosphere (N(2)-MAE). The extraction yields of vitamin C, alpha-tocopherol and gamma-tocopherol in VMAE were higher than that in air-MAE, 35% increments of vitamin C from green pepper, 22% increments of alpha-tocopherol and 47% increments of gamma-tocopherol from tea leaves were obtained, respectively. The comparable increased extraction yields of vitamin C, alpha-tocopherol and gamma-tocopherol in N(2)-MAE to that in air-MAE confirmed that oxygen in system was the crucial factor for the oxidation of vitamin C and vitamin E, VMAE was beneficial for the extraction of these oxygen-sensitive compounds. In addition, the subpressure invacuo in the VMAE system also showed positive affect on the extraction yields. On the basis of preventing oxidation and improving extraction efficiency of target compounds because of less oxygen and subpressure invacuo in the extraction system, VMAE has good potential for the extraction of oxygen-sensitive and thermosensitive compounds from plant samples.

  5. Comparison of low-level polycyclic aromatic hydrocarbons in sediment revealed by Soxhlet extraction, microwave-assisted extraction, and pressurized liquid extraction

    International Nuclear Information System (INIS)

    Itoh, Nobuyasu; Numata, Masahiko; Aoyagi, Yoshie; Yarita, Takashi

    2008-01-01

    We analyzed polycyclic aromatic hydrocarbons (PAHs) present in lake sediment at low levels ( -1 ) by using Soxhlet extraction (Soxhlet), microwave-assisted extraction (MAE), and pressurized liquid extraction (PLE) in combination with gas chromatography and isotope-dilution mass spectrometry. Although all extraction techniques showed good repeatability for five target PAHs (relative standard deviation MAE > Soxhlet. Differences in the results originated mainly from differences in the extraction efficiencies of the techniques for native PAHs, because all techniques gave comparable recovery yields of corresponding 13 C-labeled PAHs ( 13 C-PAHs) (51-84%). Since non-negligible amounts of both native PAHs and 13 C-PAHs were re-adsorbed on matrix in MAE, not only recovery yields of 13 C-PAHs but also efficiencies of extraction of native PAHs should be examined to evaluate the appropriateness of any analytical procedures

  6. A magnet built on bronchoscopic suction for extraction of tracheobronchial headscarf pins: a novel technique and review of a tertiary centre experience.

    Science.gov (United States)

    Elsayed, Hany H; Mostafa, Ahmed M; Soliman, Saleh; El-Bawab, Hatem Y; Moharram, Adel A; El-Nori, Ahmed A

    2016-05-01

    Airway metal pins are one of the most commonly inhaled foreign bodies in Eastern societies in young females wearing headscarves. We innovated a modified bronchoscopic technique to extract tracheobronchial headscarf pins by the insertion of a magnet to allow an easy and non-traumatic extraction of the pins. The aim of this study was to assess the feasibility and safety of our new technique and compare it with our large previous experience with the classic bronchoscopic method of extraction of tracheobronchial headscarf pins. We performed a study comparing our retrospective experience of classic bronchoscopic extraction from February 2004 to January 2014 and prospective experience with our modified technique using the magnet from January 2014 to June 2015. An institutional review board and new device approval were obtained. Three hundred and twenty-six procedures on 315 patients were performed during our initial 10-year experience. Of them, 304 patients were females. The median age of our group was 13 (0-62). The median time from inhalation to procedure was 1 day (0-1022). After introducing our modified new technique using the magnet, 20 procedures were performed. Nineteen were females. The median time of the procedure and the need to forcefully bend the pin for extraction were in favour of the new technique in comparison with our classic approach (2 vs 6 min; P magnets was safer and simpler in comparison with our large experience with the classic approach. We advise the use of this device (or concept) in selected patients in centres dealing with this problem. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Regional wall thickening in gated myocardial perfusion SPECT in a Japanese population: effect of sex, radiotracer, rotation angles and frame rates

    Energy Technology Data Exchange (ETDEWEB)

    Akhter, Nasima; Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Yoneyama, Tatsuya; Taki, Junichi; Kinuya, Seigo [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa, Ishikawa (Japan)

    2008-09-15

    Gated single-photon emission computed tomography (SPECT) imaging of myocardium by {sup 99m}Tc and {sup 201}Tl is used extensively to measure quantitative cardiac functional parameters. However, factors affecting normal values for myocardial functional parameters and population-specific standards have not yet been established. The aim of the study was to determine the effect of sex, radiotracer, rotation angles and frame rates on resting myocardial wall thickening (WT) and to develop a Japanese standard of normal values for WT. Data from a total of 202 patients with low possibility of having cardiac problems were collected from nine hospitals throughout Japan. Patients were divided into five groups according to study protocol, and WT was evaluated according to the 17-segment and four-region (basal, mid and apical regions and the apex) polar map distribution. WT was generally higher in women than in men irrespective of the use of radiotracers, rotation angles or frame rates, and the difference was highly significant in the mid and apical regions. In any protocol used, resting myocardial thickening in the apex was higher than in the mid and apical regions, and thickening was lowest in the basal region, suggesting heterogeneous regional myocardial thickening (%) in normal subjects. Different rotation angles showed no significant change on WT, but different frame rates and tracers showed significant WT change in both sexes. Percent thickening of the myocardium was significantly higher in imaging by {sup 99m}Tc-labelled tracers than in {sup 201}Tl. Sex, radiotracers and frame rates had a significant effect on myocardial thickening, and the importance of population-specific standards should be emphasized. A normal database can serve as a standard for gated SPECT evaluation of myocardial thickening in a Japanese population and might be applicable to Asian populations having a similar physique. (orig.)

  8. A novel technique using the Hendrickx centrifuge for extracting winter sporangia of Synchytrium endobioticum from soil

    NARCIS (Netherlands)

    Wander, J.G.N.; Berg, van den W.; Boogert, van den P.H.J.F.; Lamers, J.G.; Leeuwen, van G.C.M.; Hendrickx, G.; Bonants, P.J.M.

    2007-01-01

    A zonal centrifugation method, known as the Hendrickx centrifuge technique, was tested for routine detection of winter sporangia of Synchytrium endobioticum in soil. In four experiments the ability of the Hendrickx centrifuge to extract the sporangia from soil was compared with a method used by the

  9. Comparison of extraction and clean-up techniques for the ...

    African Journals Online (AJOL)

    user

    ultrasonication and mechanical shaking used in the extraction of a low-level PAH soil certified ... hydrocarbons (PAHs), soil, solid phase extraction (SPE), soxhlet extraction, ultrasonication. ... soxhlet) (Lopez-Avila et al., 1993) supercritical fluid.

  10. Comparison of biological properties of 99mTc-labeled cyclic RGD Peptide trimer and dimer useful as SPECT radiotracers for tumor imaging

    International Nuclear Information System (INIS)

    Zhao, Zuo-Quan; Yang, Yong; Fang, Wei; Liu, Shuang

    2016-01-01

    Introduction: This study sought to evaluate a 99m Tc-labeled trimeric cyclic RGD peptide ( 99m Tc-4P-RGD 3 ) as the new radiotracer for tumor imaging. The objective was to compare its biological properties with those of 99m Tc-3P-RGD 2 in the same animal model. Methods: HYNIC-4P-RGD 3 was prepared by reacting 4P-RGD 3 with excess HYNIC-OSu in the presence of diisopropylethylamine. 99m Tc-4P-RGD 3 was prepared using a kit formulation, and evaluated for its tumor-targeting capability and biodistribution properties in the BALB/c nude mice with U87MG human glioma xenografts. Planar and SPECT imaging studies were performed in athymic nude mice with U87MG glioma xenografts. For comparison purpose, 99m Tc-3P-RGD 2 (a α v β 3 -targeted radiotracer currently under clinical evaluation for tumor imaging in cancer patients) was also evaluated in the same animal models. Blocking experiments were used to demonstrate the α v β 3 specificity of 99m Tc-4P-RGD 3 . Results: 99m Tc-4P-RGD 3 was prepared with > 95% RCP and high specific activity (~ 200 GBq/μmol). 99m Tc-4P-RGD 3 and 99m Tc-3P-RGD 2 shared almost identical tumor uptake and similar biodistribution properties. 99m Tc-4P-RGD 3 had higher uptake than 99m Tc-3P-RGD 2 in the intestines and kidneys; but it showed better metabolic stability. The U87MG tumors were clearly visualized by SPECT with excellent contrast with 99m Tc-4P-RGD 3 and 99m Tc-3P-RGD 2 . Conclusion: Increasing peptide multiplicity from 3P-RGD 2 to 4P-RGD 3 offers no advantages with respect to the tumor-targeting capability. 99m Tc-4P-RGD 3 is as good a SPECT radiotracer as 99m Tc-3P-RGD 2 for imaging α v β 3 -positive tumors. -- Graphical abstract: This report presents evaluations of a 99m Tc-labeled cyclic RGD peptide trimer ( 99m Tc-4P-RGD 3 ) as the new SPECT radiotracer for tumor imaging. It was found that 99m Tc-4P-RGD 3 was able to accumulate in the xenografted U87MG tumors with high specificity. Display Omitted

  11. Determination of the filtration velocities and mean velocity in ground waters using radiotracers

    International Nuclear Information System (INIS)

    Duran P, Oscar; Diaz V, Francisco; Heresi M, Nelida

    1994-01-01

    An experimental method to determine filtration, or, Darcy velocity and mean velocity in underground waters using radiotracers, is described. After selecting the most appropriate tracers, from 6 chemical compounds, to measure water velocity, a method to measure filtration velocity was developed. By fully labelling the water column with 2 radioisotopes, Br and tritium, almost identical values were obtained for the aquifer filtration velocity in the sounding S1. This value was 0.04 m/d. Field porosity was calculated at 11% and mean velocity at 0.37 m.d. With the filtration velocity value and knowing the hydraulic variation between the soundings S1 and S2 placed at 10 meters, field permeability was estimated at 2.4 x 10 m/s. (author)

  12. Extraction of bioactive carbohydrates from artichoke (Cynara scolymus L.) external bracts using microwave assisted extraction and pressurized liquid extraction.

    Science.gov (United States)

    Ruiz-Aceituno, Laura; García-Sarrió, M Jesús; Alonso-Rodriguez, Belén; Ramos, Lourdes; Sanz, M Luz

    2016-04-01

    Microwave assisted extraction (MAE) and pressurized liquid extraction (PLE) methods using water as solvent have been optimized by means of a Box-Behnken and 3(2) composite experimental designs, respectively, for the effective extraction of bioactive carbohydrates (inositols and inulin) from artichoke (Cynara scolymus L.) external bracts. MAE at 60 °C for 3 min of 0.3 g of sample allowed the extraction of slightly higher concentrations of inositol than PLE at 75 °C for 26.7 min (11.6 mg/g dry sample vs. 7.6 mg/g dry sample). On the contrary, under these conditions, higher concentrations of inulin were extracted with the latter technique (185.4 mg/g vs. 96.4 mg/g dry sample), considering two successive extraction cycles for both techniques. Both methodologies can be considered appropriate for the simultaneous extraction of these bioactive carbohydrates from this particular industrial by-product. To the best of our knowledge this is the first time that these techniques are applied for this purpose. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Ultra-performance liquid chromatography MS/MS method for the determination of parabens in compost from sewage sludge: comparison of the efficiency of two extraction techniques.

    Science.gov (United States)

    Benítez-Villalba, Julio César; Zafra-Gómez, Alberto; Dorival-García, Noemí; Camino-Sánchez, Francisco Javier; Cantarero, Samuel; Vílchez, José Luis

    2013-08-01

    The efficiency of two extraction techniques--ultrasound-assisted extraction and pressurized liquid extraction--are compared and evaluated in the determination of parabens in compost samples. The extraction parameters for each technique were accurately optimized. The selected compounds were detected and quantified using ultra-performance LC MS/MS, operating in negative ESI and in SRM mode. The analytes were separated in less than 5 min. Ethylparaben (ring-(13)C6 labeled) was used as an internal standard. Two selective, sensitive, and accurate analytical methods were developed and validated. The LODs of the methods ranged from 3 to 7 ng/g and the LOQs from 10 to 23 ng/g, while inter- and intraday variability was under 6% in all cases. The methods were validated separately by using matrix-matched calibration and recovery assays with spiked samples. Recovery rates ranged from 94.0 to 105.0%. Compost samples were taken from different composting plants. Although the statistical comparison demonstrated no statistically significant differences between the two extraction techniques, the method based on pressurized liquid extraction was more sensitive than the ultrasound extraction based method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Anesthetic Efficacy of 4 % Articaine During Extraction of the Mandibular Posterior Teeth by Using Inferior Alveolar Nerve Block and Buccal Infiltration Techniques.

    Science.gov (United States)

    El-Kholey, Khalid E

    2017-03-01

    The study was designed to evaluate the anesthetic efficacy of 4 % articaine with 1:100,000 epinephrine (A100) in infiltration and inferior alveolar nerve block (IANB) anesthetic techniques for the pain control during extraction of the mandibular posterior teeth. This prospective randomized single-blind clinical trial included 100 patients needing extraction of at least two mandibular molars. Patients received either infiltration in the buccal vestibule opposite to the first molar supplemented with lingual infiltration or standard IANB with A100. For assessment of depth of anesthesia obtained by the two anaethetic techniques, presence or absence of pain during the extraction were rated using the visual analog scale. Fifty patients received infiltration anesthesia and fifty patients were anesthetized by IANB. The success rate of pain-free extraction after buccal infiltration was 94 %, whereas by using IANB with the same anesthetic it was 92 %. No statistical differences were detected in the success rates between the two anesthetic techniques ( P  = 0.15). Buccal Infiltration can be considered a good option during extraction of the mandibular molar and premolar teeth of course, with supplemental lingual anesthesia.

  15. Preliminary Laboratory-scale Study Temperature Shape Memory Alloy for Sensor Application

    International Nuclear Information System (INIS)

    Tippayakul, C.; Petchrak, A.; Wetchagarun, S.

    2014-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. Thailand Institute of Nuclear Technology (TINT) is currently conducting R&D on this technique aiming to promote the radiotracer use in Thailand. In this paper, a preliminary study of the leak detection using radiotracer on laboratory-scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The radiotracer in form of NH4Br powder was irradiated in Thai Research Reactor (TRR-1/M1) to produce Br-82. The irradiated target was subsequently prepared in the form of aqueous solution in a hot cell ready for injection into the experimental system as the radiotracer. A relatively simplified experimental setup was used with three NaI detectors being placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating that the simplified experimental setup was not adequate for the leak rate study. Hence, further study with more elaborate experimental setup was required before applying this technique in the actual industrial system.

  16. Liquid membrane extraction techniques for trace metal analysis and speciation in environmental and biological matrices

    Energy Technology Data Exchange (ETDEWEB)

    Ndungu, Kuria

    1999-04-01

    In this thesis, liquid-membrane-based methods for the analysis of trace metal species in samples of environmental and biological origin were developed. By incorporating extracting reagents in the membrane liquid, trace metal ions were selectively separated from humic-rich natural waters and urine samples, prior to their determination using various instrumental techniques. The extractions were performed in closed flow systems thus allowing easy automation of both the sample clean-up and enrichment. An acidic organophosphorus reagent (DEHPA) and a basic tetraalkylammonium reagent (Aliquat-336) were used as extractants in the membrane liquid to selectively extract and enrich cationic and anionic metal species respectively. A speciation method for chromium species was developed that allowed the determination of cationic Cr(III) species and anionic CR(VI) species in natural water samples without the need of a chromatographic separation step prior to their detection. SLM was also coupled on-line to potentiometric stripping analysis providing a fast and sensitive method for analysis of Pb in urine samples. A microporous membrane liquid-liquid extraction (MMLLE) method was developed for the determination of organotin compounds in natural waters that reduced the number of manual steps involved in the LLE of organotin compounds prior to their CC separation. Clean extracts obtained after running unfiltered humic-rich river water samples through the MMLLE flow system allowed selective determination of all the organotin compounds in a single run using GC-MS in the selected ion monitoring mode (SIM) 171 refs, 9 figs, 4 tabs

  17. Glu-Ureido-Based Inhibitors of Prostate-Specific Membrane Antigen: Lessons Learned During the Development of a Novel Class of Low-Molecular-Weight Theranostic Radiotracers

    Czech Academy of Sciences Publication Activity Database

    Kopka, K.; Benesova, M.; Bařinka, Cyril; Haberkorn, U.; Babich, J.

    2017-01-01

    Roč. 58, Suppl. 2 (2017), s. 17-26 ISSN 0161-5505 Institutional support: RVO:86652036 Keywords : small-molecule PSMA inhibitors * theranostic PSMA radioligands * PSMA radiotracers Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Cell biology Impact factor: 6.646, year: 2016

  18. Developing a complex independent component analysis technique to extract non-stationary patterns from geophysical time-series

    Science.gov (United States)

    Forootan, Ehsan; Kusche, Jürgen

    2016-04-01

    Geodetic/geophysical observations, such as the time series of global terrestrial water storage change or sea level and temperature change, represent samples of physical processes and therefore contain information about complex physical interactionswith many inherent time scales. Extracting relevant information from these samples, for example quantifying the seasonality of a physical process or its variability due to large-scale ocean-atmosphere interactions, is not possible by rendering simple time series approaches. In the last decades, decomposition techniques have found increasing interest for extracting patterns from geophysical observations. Traditionally, principal component analysis (PCA) and more recently independent component analysis (ICA) are common techniques to extract statistical orthogonal (uncorrelated) and independent modes that represent the maximum variance of observations, respectively. PCA and ICA can be classified as stationary signal decomposition techniques since they are based on decomposing the auto-covariance matrix or diagonalizing higher (than two)-order statistical tensors from centered time series. However, the stationary assumption is obviously not justifiable for many geophysical and climate variables even after removing cyclic components e.g., the seasonal cycles. In this paper, we present a new decomposition method, the complex independent component analysis (CICA, Forootan, PhD-2014), which can be applied to extract to non-stationary (changing in space and time) patterns from geophysical time series. Here, CICA is derived as an extension of real-valued ICA (Forootan and Kusche, JoG-2012), where we (i) define a new complex data set using a Hilbert transformation. The complex time series contain the observed values in their real part, and the temporal rate of variability in their imaginary part. (ii) An ICA algorithm based on diagonalization of fourth-order cumulants is then applied to decompose the new complex data set in (i

  19. Comparative of signal processing techniques for micro-Doppler signature extraction with automotive radar systems

    Science.gov (United States)

    Rodriguez-Hervas, Berta; Maile, Michael; Flores, Benjamin C.

    2014-05-01

    In recent years, the automotive industry has experienced an evolution toward more powerful driver assistance systems that provide enhanced vehicle safety. These systems typically operate in the optical and microwave regions of the electromagnetic spectrum and have demonstrated high efficiency in collision and risk avoidance. Microwave radar systems are particularly relevant due to their operational robustness under adverse weather or illumination conditions. Our objective is to study different signal processing techniques suitable for extraction of accurate micro-Doppler signatures of slow moving objects in dense urban environments. Selection of the appropriate signal processing technique is crucial for the extraction of accurate micro-Doppler signatures that will lead to better results in a radar classifier system. For this purpose, we perform simulations of typical radar detection responses in common driving situations and conduct the analysis with several signal processing algorithms, including short time Fourier Transform, continuous wavelet or Kernel based analysis methods. We take into account factors such as the relative movement between the host vehicle and the target, and the non-stationary nature of the target's movement. A comparison of results reveals that short time Fourier Transform would be the best approach for detection and tracking purposes, while the continuous wavelet would be the best suited for classification purposes.

  20. Radiotracer studies in cavernous marble at Kamathikhairy Dam site, Pench Project (Maharashtra)

    International Nuclear Information System (INIS)

    Nath, Ravendra; Mahajan, N.M.; Vaidya, S.D.

    1982-01-01

    Radiotracer studies with tritiated water at Pench Project site conclusively proved that the cavernous marble upstream of the saddle dam is continuous with the marble occuring near the spillway portion of the main dam and that there is fast subterranean flow of water through the cavernous marble here. It is also established that this marble band upstream of the dam is interconnected with the marble band occuring in the vicinity of Pali village about 3 km downstream of the dam. Though big unclogged subterranean channels do not seem to exist in this region, which might have resulted in heavy leakage from the impounded reservoir, yet the possibility of some leakage of the water through the cavernous marble cannot be ruled out, due to the interconnection of the marble occuring upstream of the dam with the downstream marble band. (author)

  1. Radiotracer studies on protein metabolism in different focuses of growth in vivo

    International Nuclear Information System (INIS)

    Rapoport, E.A.; Konikova, A.S.

    1979-01-01

    The role of various components of protein turnover in the liver growth induced by partial hepatectomy or phenobarbital as well as in malignant tumours has been studied with a radiotracer method. The ratio of the utilized precursors of exo- and endogenous origin during the formation of protein in focuses of growth, is labile, depends on a number of factors and varies even in the subcellular structures of the cell nucleus. It is probable that due to their reutilization through transreactions the protein structural units have in some focuses of growth and during formation of some proteins a definite superiority over the free aminoacids. It is also shown that the release of proteins and their degradation products from Walker 256 carcinosarcoma and the reutilization of proteins and their degradation products by sarcoma M-1 contribute to the protein turnover in the tumours. 8author)

  2. Comparative Evaluation of Different Extraction Techniques and Solvents for the Assay of Phytochemicals and Antioxidant Activity of Hashemi Rice Bran.

    Science.gov (United States)

    Ghasemzadeh, Ali; Jaafar, Hawa Z E; Juraimi, Abdul Shukor; Tayebi-Meigooni, Amin

    2015-06-11

    Secondary metabolite contents (total phenolic, flavonoid, tocopherol, and tocotrienol) and antioxidant activities of Hashemi rice bran extracts obtained by ultrasound-assisted and traditional solvent (ethanol and 50:50 (v/v) ethanol-water) extraction techniques were compared. Phenolic and, flavonoid compounds were identified using ultra-high performance liquid chromatography and method validation was performed. Significant differences (p phytochemical contents and antioxidant activities. The extracts obtained using the ethanol-water (50:50 v/v) ultrasonic technique showed the highest amounts of total phenolics (288.40 mg/100 g dry material (DM)), total flavonoids (156.20 mg/100 g DM), and total tocotrienols (56.23 mg/100 g DM), and the highest antioxidant activity (84.21% 1,1-diphenyl-2-picrylhydrazyl (DPPH), 65.27% β-carotene-linoleic bleaching and 82.20% nitric oxide scavenging activity). Secondary metabolite contents and antioxidant activities of the rice bran extracts varied depending of the extraction method used, and according to their effectiveness, these were organized in a decreasing order as follows: ethanol-water (50:50 v/v) ultrasonic, ethanol-water (50:50 v/v) maceration, ethanol ultrasonic and ethanol maceration methods. Ferulic, gallic and chlorogenic acids were the most abundant phenolic compounds in rice bran extracts. The phytochemical constituents of Hashemi rice bran and its antioxidant properties provides insights into its potential application to promote health.

  3. Radiosynthesis and ex vivo evaluation of [{sup 11}C]-SIB-1553A as a PET radiotracer for {beta}4 selective subtype nicotinic acetylcholine receptor

    Energy Technology Data Exchange (ETDEWEB)

    Sobrio, Franck [CEA, DSV, I2BM, CINAPS, LDMTEP, Caen, F-14074 (France); Universite de Caen Basse-Normandie, UMR CEA E2, Centre Cyceron, Caen, F-14074 (France)], E-mail: sobrio@cyceron.fr; Quentin, Thomas; Dhilly, Martine; Bourdier, Thomas; Tymciu, Sylvie; Debruyne, Daniele; Barre, Louisa [CEA, DSV, I2BM, CINAPS, LDMTEP, Caen, F-14074 (France); Universite de Caen Basse-Normandie, UMR CEA E2, Centre Cyceron, Caen, F-14074 (France)

    2008-04-15

    [{sup 11}C]-SIB-1553A (({+-})-4-[2-((N-[{sup 11}C]-methyl)-2-pyrrolidinyl)ethyl]thiophenol) was labelled with carbon-11 (t{sub 1/2}=20.4 min) and evaluated in vivo as potential radiotracer for noninvasive assessment of the {beta}4 subunit nicotinic acetylcholine neurotransmission system with positron emission tomography (PET). The labelling precursor was obtained within five steps from N-Boc-prolinal in 45-56% overall yields. The radiosynthesis of [{sup 11}C]-SIB-1553A was achieved by a selective N-[{sup 11}C]-methylation in 32 min with a radiochemical purity greater than 97%, 7.5-30 GBq/{mu}mol of specific radioactivity and 55-65% radiochemical yield (decay corrected, based on [{sup 11}C]methyl iodide). The ex vivo pharmacological profile of [{sup 11}C]-SIB-1553A was evaluated in rats with biodistribution studies in organs and in brain structures by autoradiography. The radiotracer uptake in the brain reached 0.49 %ID/g at 10 min and no brain radiometabolite was detected 40 min after intravenous injection. The quantification of radioactivity in various cerebral structures indicated a significantly higher radioactivity level at 15 min than at 30 min. Among the {beta}4 nAChR subunit-rich structures studied in the rat brain, only the thalamus at 15 and 30 min and the hippocampus at 30 min showed significantly higher uptake. Moreover, competition studies performed with SIB-1553A (15 min before the radiotracer injection) revealed only a low specific binding estimated to 7% of the total binding at 15 min and 13% at 30 min.

  4. Comparison of extraction and clean-up techniques for the ...

    African Journals Online (AJOL)

    user

    Six different extraction solvents: acetone, cyclohexane, 2- propanol, methanol, acetonitrile and dichloromethane, were tested to select the most suitable solvent for the extraction of the 16 PAHs from the certified soil reference material. The results were compared to determine the method with the highest extraction efficiency.

  5. Report on second FAO/IAEA research coordination meeting on radiotracer studies of fungicide residues in food plants - Neuherberg, Germany, F.R., 4-8 May 1987

    International Nuclear Information System (INIS)

    1987-01-01

    In 1984, the FAO/IAEA Joint Division established the coordinated research programme on 'Radiotracer studies of fungicide residues in food plants'. The first FAO/IAEA research coordination meeting of the programme was held in Panama City, Panama in October 1985. It established a framework for experiments by the participating researchers to investigate metabolism and terminal residues of ethylenebisdithiocarbamates in food plants using 14 C-labelled materials with associated and other techniques. In this second report, progress made since the first report is presented and the further research needed to fulfill the objectives of the programme is outlined. The objectives of the meeting were as follows: To review progress within the coordinated research programme; To discuss problems pertinent to methodologies and labelled substrates; To prepare a report and recommendations with particular reference to future needs and priorities. The 12 papers presented at the meeting are given in summary form. (orig./MG)

  6. Evaluation of a new eastern blotting technique for the analysis of ginsenoside Re in American ginseng berry pulp extracts.

    Science.gov (United States)

    Morinaga, Osamu; Uto, Takuhiro; Yuan, Chun-Su; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2010-06-01

    A new eastern blotting technique has been established for ginsenoside Re (G-Re) contained in American ginseng berry pulp extracts. G-Re in American ginseng berry pulp was extracted using 100% methanol, 100% ethanol, 50% aqueous methanol, and 50% aqueous ethanol. The combined crude extracts were applied onto a polyethersulfone membrane and developed using the methanol-water-acetic acid solvent system (45:55:1 v/v). Separated components were immunostained using anti-G-Re monoclonal antibody. G-Re was first specifically detected and then quantitatively analyzed using NIH Imaging software. We also confirmed that the most suitable solvent was 50% aqueous methanol for extracting G-Re from American ginseng berry pulp. (c) 2009 Elsevier B.V. All rights reserved.

  7. Comparison of surface extraction techniques performance in computed tomography for 3D complex micro-geometry dimensional measurements

    DEFF Research Database (Denmark)

    Torralba, Marta; Jiménez, Roberto; Yagüe-Fabra, José A.

    2018-01-01

    micro-geometries as well (i.e., in the sub-mm dimensional range). However, there are different factors that may influence the CT process performance, being one of them the surface extraction technique used. In this paper, two different extraction techniques are applied to measure a complex miniaturized......The number of industrial applications of computed tomography (CT) for dimensional metrology in 100–103 mm range has been continuously increasing, especially in the last years. Due to its specific characteristics, CT has the potential to be employed as a viable solution for measuring 3D complex...... dental file by CT in order to analyze its contribution to the final measurement uncertainty in complex geometries at the mm to sub-mm scales. The first method is based on a similarity analysis: the threshold determination; while the second one is based on a gradient or discontinuity analysis: the 3D...

  8. Enzyme assisted extraction of biomolecules as an approach to novel extraction technology: A review.

    Science.gov (United States)

    Nadar, Shamraja S; Rao, Priyanka; Rathod, Virendra K

    2018-06-01

    An interest in the development of extraction techniques of biomolecules from various natural sources has increased in recent years due to their potential applications particularly for food and nutraceutical purposes. The presence of polysaccharides such as hemicelluloses, starch, pectin inside the cell wall, reduces the extraction efficiency of conventional extraction techniques. Conventional techniques also suffer from low extraction yields, time inefficiency and inferior extract quality due to traces of organic solvents present in them. Hence, there is a need of the green and novel extraction methods to recover biomolecules. The present review provides a holistic insight to various aspects related to enzyme aided extraction. Applications of enzymes in the recovery of various biomolecules such as polyphenols, oils, polysaccharides, flavours and colorants have been highlighted. Additionally, the employment of hyphenated extraction technologies can overcome some of the major drawbacks of enzyme based extraction such as longer extraction time and immoderate use of solvents. This review also includes hyphenated intensification techniques by coupling conventional methods with ultrasound, microwave, high pressure and supercritical carbon dioxide. The last section gives an insight on application of enzyme immobilization as a strategy for large scale extraction. Immobilization of enzymes on magnetic nanoparticles can be employed to enhance the operational performance of the system by multiple use of expensive enzymes making them industrially and economically feasible. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Extraction of citral oil from lemongrass (Cymbopogon Citratus) by steam-water distillation technique

    Science.gov (United States)

    Alam, P. N.; Husin, H.; Asnawi, T. M.; Adisalamun

    2018-04-01

    In Indonesia, production of citral oil from lemon grass (Cymbopogon Cytratus) is done by a traditional technique whereby a low yield results. To improve the yield, an appropriate extraction technology is required. In this research, a steam-water distillation technique was applied to extract the essential oil from the lemongrass. The effects of sample particle size and bed volume on yield and quality of citral oil produced were investigated. The drying and refining time of 2 hours were used as fixed variables. This research results that minimum citral oil yield of 0.53% was obtained on sample particle size of 3 cm and bed volume of 80%, whereas the maximum yield of 1.95% on sample particle size of 15 cm and bed volume of 40%. The lowest specific gravity of 0.80 and the highest specific gravity of 0.905 were obtained on sample particle size of 8 cm with bed volume of 80% and particle size of 12 cm with bed volume of 70%, respectively. The lowest refractive index of 1.480 and the highest refractive index of 1.495 were obtained on sample particle size of 8 cm with bed volume of 70% and sample particle size of 15 cm with bed volume of 40%, respectively. The solubility of the produced citral oil in alcohol was 70% in ratio of 1:1, and the citral oil concentration obtained was around 79%.

  10. Receptor binding radiotracers for the angiotensin II receptor: radioiodinated [Sar1, Ile8]angiotensin II

    International Nuclear Information System (INIS)

    Gibson, R.E.; Beauchamp, H.T.; Fioravanti, C.; Brenner, N.; Burns, H.D.

    1994-01-01

    The potential for imaging the angiotensin II receptor was evaluated using the radioiodinated peptide antagonist [ 125 I][Sar 1 , Ile 8 ]angiotensin II. The radioligand provides a receptor-mediated signal in several tissues in rat (kidneys, adrenal and liver). The receptor-mediated signal of 3% ID/g kidney cortex should be sufficient to permit imaging, at least via SPECT. The radiotracer is sensitive to reductions in receptor concentration and can be used to define in vivo dose-occupancy curves of angiotensin II receptor ligands. Receptor-mediated images of [ 123 I][Sar 1 , Ile 8 ]angiotensin II were obtained in the rat kidney and Rhesus monkey liver. (author)

  11. 99mTcN-gatifloxacin dithiocarbamate complex. A novel multi-drug-resistance Streptococcus pneumoniae (MRSP) infaction radiotracer

    International Nuclear Information System (INIS)

    Syed Qaiser Shah; Mohammad Rafiullah Khan

    2011-01-01

    Gatifloxacin (GTN) was derivatized to its dithiocarbamate derivative and its radiolabeling with technetium-99m ( 99m Tc) using the [ 99m Tc≡N] 2+ core was investigated. The appropriateness of the 99m TcN - gatifloxacin dithiocarbamate ( 99m TcN - GTND) complex as a potential multi-drug-resistance Streptococcus pneumoniae (MRSP) infection radiotracer was evaluated in terms of stability in saline, serum, in vitro binding with MRSP and biodistribution in artificially MRSP infected Male Wistar Rats (MWR). In saline the 99m TcN - GTND complex showed more than 90% labeling yield up to 4 h with a maximum yield of 98.25 ± 0.20%, after reconstitution. In serum the 99m TcN - GTND complex showed stability up to 16 h of incubation with the appearance of insignificant 15.95% undesirable side products. The 99m TcN - GTND complex demonstrated saturated in vitro binding with MRSP with a maximum value of 75.50 ± 1.00% (at 90 min). In MWR model of group A, almost six times higher uptake of the labeled GTND was monitored in the muscle of MWR infected with live MRSP as compared to the inflamed and normal muscles. Based on the higher labeling yield in saline, in vitro stability in serum, saturated in vitro binding with live MRSP and promising biodistribution in MWR model we recommend 99m TcN - gatifloxacin dithiocarbamate complex as a potential MRSP infection radiotracer. (author)

  12. Diffuse pulmonary uptake of bone-seeking radiotracer in bone scintigraphy of a rare case of pulmonary alveolar microlithiasis

    International Nuclear Information System (INIS)

    Fallahi, Babak; Ghafary, Bahar Moasses; Fard-Esfahani, Armaghan; Eftekhari, Mohammad

    2005-01-01

    Pulmonary alveolar microlithiasis (PAM) is a rare diffuse pulmonary disease representing microliths formed by deposition of calcium phosphonate in the alveolar airspaces. PAM is often diagnosed incidentally during chest X-ray imaging. Most of them are asymptomatic. We present a 39-year-old man referring for a bone scan due to a complaint of right leg pain. Bone scan showed diffuse uptake of bone-seeking radiotracer on both lung fields predominantly in basal regions. The bronchoalveolar lavage test confirmed the diagnosis of PAM

  13. Dopamine D2 receptor radiotracers [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride are indistinguishably inhibited by D2 agonists and antagonists ex vivo

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, Patrick N. [Institute of Medical Science, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada)], E-mail: patrick.mccormick@camhpet.ca; Kapur, Shitij [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); PET Center, Center for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Seeman, Philip [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); Department of Pharmacology, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); Wilson, Alan A. [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); PET Center, Center for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada)

    2008-01-15

    Introduction: In vitro, the dopamine D2 receptor exists in two states, with high and low affinity for agonists. The high-affinity state is the physiologically active state thought to be involved in dopaminergic illnesses such as schizophrenia. The positron emission tomography radiotracer [{sup 11}C](+)-PHNO ([{sup 11}C](+)-4-propyl-3,4,4a,5,6,10b-hexahydro-2H-naphtho[1,2-b][1,4] oxazin-9-o l), being a D2 agonist, should selectively label the high-affinity state at tracer dose and therefore be more susceptible to competition by agonist as compared to the antagonist [{sup 3}H]raclopride, which binds to both affinity states. Methods: We tested this prediction using ex vivo dual-radiotracer experiments in conscious rats. D2 antagonists (haloperidol or clozapine), a partial agonist (aripiprazole), a full agonist [(-)-NPA] or the dopamine-releasing drug amphetamine (AMPH) were administered to rats prior to an intravenous coinjection of [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride. Rats were sacrificed 60 min after radiotracer injection. Striatum, cerebellum and plasma samples were counted for {sup 11}C and {sup 3}H. The specific binding ratio {l_brace}SBR, i.e., [%ID/g (striatum)-%ID/g (cerebellum)]/(%ID/g (cerebellum){r_brace} was used as the outcome measure. Results: In response to D2 antagonists, partial agonist or full agonist, [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride SBRs responded indistinguishably in terms of both ED{sub 50} and Hill slope (e.g., (-)-NPA ED{sub 50} values are 0.027 and 0.023 mg/kg for [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride, respectively). In response to AMPH challenge, [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride SBRs were inhibited to the same degree. Conclusions: We have shown that the SBRs of [{sup 11}C](+)-PHNO- and [{sup 3}H]raclopride do not differ in their response to agonist challenge. These results do not support predictions of the in vivo binding behavior of a D2 agonist radiotracer and cast some doubt on the in vivo

  14. Separation of trivalent actinide from lanthanide by a solvent extraction technique using imidazoledithiocarboxylic acid

    International Nuclear Information System (INIS)

    Miyashita, S.; Yanaga, M.; Okuno, K.; Suganuma, H.; Satoh, I.

    2006-01-01

    The extraction behavior of 241 Am and 152,154 Eu by a solvent extraction technique using imidazoledithiocarboxylic acid (IMD) were investigated. Although the solubility of IMD into organic solvent is very poor, it was improved by the formation of ion pair with hydrophobic cation, such as tetrabutylammonium ion (TBA + ) or tetraoctylammonium ion (TOA + ). The obtained tetrabutylammonium imidazole-dithiocarboxylate (TBA + IMD - ) and tetraoctylammonium imidazoledithiocarboxylate (TOA + TMD - ) are able to solve into various organic solvents, for example cyclohexanone, chloroform and nitrobenzene, but not to solve into nonpolar alkane. The radionuclides of Am(III) and Eu(III) are able to be extracted in the region of 2 eq + IMD - /cyclohexanone and TOA + IMD - /cyclohexanone. The distribution ratio of Am(III) is higher than that of Eu(III) when the organic phase is 0.1 M TBA + IMD - /cyclohexanone and the aqueous phase is 1.0 M (H,Na)NO 3 . The separation factor (Am(III)/Eu(III)) at pH eq =5.5 is ca. 30. In the region of pH>6, the distribution ratios of Am(III) and Eu(III) in the system described above showed constant values, respectively. (author)

  15. Comparison of the Chemical Composition of “Cystoseira sedoides (Desfontaines C. Agardh” Volatile Compounds Obtained by Different Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Naima Bouzidi

    2016-01-01

    Full Text Available The volatile fraction of the brown alga Cystoseira sedoides (Desfontaines C.Agardh is prepared from the crude extract through the following three extraction methods: Hydrodistillation (HD, focused microwave assisted hydrodistillation (FMAHD and supercritical fluid extraction (SFE. The volatile fractions are analyzed by gas chromatography-flame ionization detector-mass spectrometry (GC-FID-MS, the chemical components are identified on the basis of the comparison of their retention indices with literature and their mass spectra with those reported in commercial databases. The chemical composition of the volatile fractions obtained by different extraction techniques fall into three major chemical classes: fatty acids and derivatives, sesquiterpenes, and hydrocarbons and derivatives. Others Compounds belonging to different chemical classes are found in that chemical composition.

  16. Radiotracers for the in vivo PET imagine of acetylcholinesterase in the brain

    International Nuclear Information System (INIS)

    Kilbourn, M.R.; Snyder, S.E.; Nguyen, T.; Koeppe, R.A.; Frey, K.A.; Kuhl, D.E.

    1997-01-01

    Regional brain pharmacokinetics of the piperidinyl esters have been determined in the primate brain, using Positron Emission Tomographic (PET) imaging. The propionate ester shows a faster and more complete rate of hydrolysis in regions of AChE, such as the striatum and the cortex. Regional hydrolysis rates (combined forward rate constants, k3) for these radiotracers can be calculated using a simplified analysis of tissue-time activity curves, without a need for determining metabolite-corrected plasma levels. In the striatum of the monkey, the propionate ester shows a reaction rate with the enzyme that is almost two-fold faster than the isobutyrate ester. These radiolabeled esters form a new approach to the measurement of in vivo function of AChE in the mammalian brain, including humans, and provide a method to assess changes in such enzyme activity as a result of disease or pharmacological intervention

  17. Radiotracers for the in vivo PET imagine of acetylcholinesterase in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Kilbourn, M.R.; Snyder, S.E.; Nguyen, T.; Koeppe, R.A.; Frey, K.A.; Kuhl, D.E. [University of Michigan Medical School, An Arbor (United States). Division of Nuclear Medicine

    1997-10-01

    Regional brain pharmacokinetics of the piperidinyl esters have been determined in the primate brain, using Positron Emission Tomographic (PET) imaging. The propionate ester shows a faster and more complete rate of hydrolysis in regions of AChE, such as the striatum and the cortex. Regional hydrolysis rates (combined forward rate constants, k3) for these radiotracers can be calculated using a simplified analysis of tissue-time activity curves, without a need for determining metabolite-corrected plasma levels. In the striatum of the monkey, the propionate ester shows a reaction rate with the enzyme that is almost two-fold faster than the isobutyrate ester. These radiolabeled esters form a new approach to the measurement of in vivo function of AChE in the mammalian brain, including humans, and provide a method to assess changes in such enzyme activity as a result of disease or pharmacological intervention 10 refs., 5 figs.

  18. Green bio-oil extraction for oil crops

    Science.gov (United States)

    Zainab, H.; Nurfatirah, N.; Norfaezah, A.; Othman, H.

    2016-06-01

    The move towards a green bio-oil extraction technique is highlighted in this paper. The commonly practised organic solvent oil extraction technique could be replaced with a modified microwave extraction. Jatropha seeds (Jatropha curcas) were used to extract bio-oil. Clean samples were heated in an oven at 110 ° C for 24 hours to remove moisture content and ground to obtain particle size smaller than 500μm. Extraction was carried out at different extraction times 15 min, 30 min, 45 min, 60 min and 120 min to determine oil yield. The biooil yield obtained from microwave assisted extraction system at 90 minutes was 36% while that from soxhlet extraction for 6 hours was 42%. Bio-oil extracted using the microwave assisted extraction (MAE) system could enhance yield of bio-oil compared to soxhlet extraction. The MAE extraction system is rapid using only water as solvent which is a nonhazardous, environment-friendly technique compared to soxhlet extraction (SE) method using hexane as solvent. Thus, this is a green technique of bio-oil extraction using only water as extractant. Bio-oil extraction from the pyrolysis of empty fruit bunch (EFB), a biomass waste from oil palm crop, was enhanced using a biocatalyst derived from seashell waste. Oil yield for non-catalytic extraction was 43.8% while addition of seashell based biocatalyst was 44.6%. Oil yield for non-catalytic extraction was 43.8% while with addition of seashell-based biocatalyst was 44.6%. The pH of bio-oil increased from 3.5 to 4.3. The viscosity of bio-oil obtained by catalytic means increased from 20.5 to 37.8 cP. A rapid and environment friendly extraction technique is preferable to enhance bio-oil yield. The microwave assisted approach is a green, rapid and environmental friendly extraction technique for the production of bio-oil bearing crops.

  19. Decomposition of 14C - malathion in three Brazilian soil samples

    International Nuclear Information System (INIS)

    Helene, C.G.; Ruegg, E.F.

    1982-01-01

    The degradation of 14 C-malathion in soil was examined using gas chromatography and radiotracer techniques. About half of the malathion added was degraded within a day in soil from three regions of Brazil. Almost all the radiolabelled material extracted from the Red Latosol (Londrina, PR) was malathion, but metabolites were extracted from the 'Sandy' cerrado soil (Planaltina, DF) and Dark-Red Latosol (Passo Fundo, RS). The proportion of metabolites in the extracts increased until most of the malathion was degraded, after four days. Radiocarbon dioxide was liberated from all three soils at similar rates. When about half of the label had been recovered as carbon dioxide after eight weeks, the rate of evolution diminished. (Author) [pt

  20. Studies on the transfer of Cs, Sr, Co, Mn and Zn from soil to plants and from medium to mushrooms by using radiotracer

    International Nuclear Information System (INIS)

    Ban-nai, Tadaaki; Muramatsu, Yasuyuki; Yoshida, Satoshi; Yanagisawa, Kei

    1996-01-01

    Radiotracer experiments were carried out to study radionuclide uptake by plants and mushrooms. Transfer factors of radionuclides from soil to leaf vegetables (cabbage, Chinese cabbage, komatsuna, spinach and lettuce) have been determined by radiotracers. The transfer factors of radioactive Cs, Sr, Mn, Co and Zn for edible parts of vegetables were 0.11, 0.24, 0.61, 0.05 and 0.52, respectively. The transfer factors of Mn, Co and Zn for spinach were higher than those for the other vegetables. The transfer factors of Cs for different organs of the leaf vegetables were rather homogeneous. The transfer factors of Sr and Mn were higher for older (outer) leaves than younger (inner) ones. In contrast to Sr and Mn, transfer factors of Zn for younger leaves were higher than those for older ones. In order to study radionuclide uptake by mushrooms, cultivation experiments in flasks were carried out using radiotracers, 137 Cs, 85 Sr, 60 Co, 54 Mn and 65 Zn. Four mushroom species Hebeloma vinosophyllum, Flammulina velutipes, Agrocybe cylindracea and Coprinus phlyctidosporus were used. In addition, Medicago sativa was also tested. Mushrooms tended to accumulate Cs, although there was a large difference between mushroom species. The concentration ratio had the highest value of 21 for Cs in vinosophyllum. The value was much higher than that in the plant sample. The present findings agreed with our previous observations in which Hebeloma species collected in forests contained large amount of 137 Cs. The effects of stable elements in the medium on the accumulations were investigated. The concentration ratios of Cs, Sr and Co were not influenced highly by coexisting stable elements in the medium. However, the ratio of Mn decreased as the amount of coexisting stable elements in the medium was increased. (J.P.N.)

  1. Evaluation of Fluorine-18-Labeled α1(I-N-Telopeptide Analogs as Substrate-Based Radiotracers for PET Imaging of Melanoma-Associated Lysyl Oxidase

    Directory of Open Access Journals (Sweden)

    Manuela Kuchar

    2018-04-01

    Full Text Available Accumulating evidence suggests an unequivocal role of lysyl oxidases as key players of tumor progression and metastasis, which renders this enzyme family highly attractive for targeted non-invasive functional imaging of tumors. Considering their function in matrix remodeling, malignant melanoma appears as particularly interesting neoplasia in this respect. For the development of radiotracers that enable PET imaging of the melanoma-associated lysyl oxidase activity, substrates derived from the type I collagen α1 N-telopeptide were labeled with fluorine-18 using N-succinimidyl 4-[18F]fluorobenzoate ([18F]SFB as prosthetic reagent. With regards to potential crosslinking to tumor-associated collagen in vivo, their interaction with triple-helical type I collagen was studied by SPR. A mouse model of human melanoma was established on the basis of the A375 cell line, for which the expression of the oncologically relevant lysyl oxidase isoforms LOX and LOXL2 was demonstrated in Western blot and immunohistochemical experiments. The radiopharmacological profiles of the peptidic radiotracers were evaluated in normal rats and A375 melanoma-bearing mice by ex vivo metabolite analysis, whole-body biodistribution studies and dynamic PET imaging. Out of three 18F-labeled telopeptide analogs, the one with the most favorable substrate properties has shown favorable tumor uptake and tumor-to-muscle ratio. Lysyl oxidase-mediated tumor uptake was proven by pharmacological inhibition using β-aminopropionitrile and by employing negative-control analogs of impeded or abolished targeting capability. The latter were obtained by substituting the lysine residue by ornithine and norleucine, respectively. Comparing the tumor uptake of the lysine-containing peptide with that of the non-functional analogs indicate the feasibility of lysyl oxidase imaging in melanoma using substrate-based radiotracers.

  2. Evaluation of Fluorine-18-Labeled α1(I)-N-Telopeptide Analogs as Substrate-Based Radiotracers for PET Imaging of Melanoma-Associated Lysyl Oxidase.

    Science.gov (United States)

    Kuchar, Manuela; Neuber, Christin; Belter, Birgit; Bergmann, Ralf; Lenk, Jens; Wodtke, Robert; Kniess, Torsten; Steinbach, Jörg; Pietzsch, Jens; Löser, Reik

    2018-01-01

    Accumulating evidence suggests an unequivocal role of lysyl oxidases as key players of tumor progression and metastasis, which renders this enzyme family highly attractive for targeted non-invasive functional imaging of tumors. Considering their function in matrix remodeling, malignant melanoma appears as particularly interesting neoplasia in this respect. For the development of radiotracers that enable PET imaging of the melanoma-associated lysyl oxidase activity, substrates derived from the type I collagen α1 N-telopeptide were labeled with fluorine-18 using N -succinimidyl 4-[ 18 F]fluorobenzoate ([ 18 F]SFB) as prosthetic reagent. With regards to potential crosslinking to tumor-associated collagen in vivo , their interaction with triple-helical type I collagen was studied by SPR. A mouse model of human melanoma was established on the basis of the A375 cell line, for which the expression of the oncologically relevant lysyl oxidase isoforms LOX and LOXL2 was demonstrated in Western blot and immunohistochemical experiments. The radiopharmacological profiles of the peptidic radiotracers were evaluated in normal rats and A375 melanoma-bearing mice by ex vivo metabolite analysis, whole-body biodistribution studies and dynamic PET imaging. Out of three 18 F-labeled telopeptide analogs, the one with the most favorable substrate properties has shown favorable tumor uptake and tumor-to-muscle ratio. Lysyl oxidase-mediated tumor uptake was proven by pharmacological inhibition using β-aminopropionitrile and by employing negative-control analogs of impeded or abolished targeting capability. The latter were obtained by substituting the lysine residue by ornithine and norleucine, respectively. Comparing the tumor uptake of the lysine-containing peptide with that of the non-functional analogs indicate the feasibility of lysyl oxidase imaging in melanoma using substrate-based radiotracers.

  3. Chemical Variability and Biological Activities of Brassica rapa var. rapifera Parts Essential Oils Depending on Geographic Variation and Extraction Technique.

    Science.gov (United States)

    Saka, Boualem; Djouahri, Abderrahmane; Djerrad, Zineb; Terfi, Souhila; Aberrane, Sihem; Sabaou, Nasserdine; Baaliouamer, Aoumeur; Boudarene, Lynda

    2017-06-01

    In the present work, the Brassica rapa var. rapifera parts essential oils and their antioxidant and antimicrobial activities were investigated for the first time depending on geographic origin and extraction technique. Gas-chromatography (GC) and GC/mass spectrometry (MS) analyses showed several constituents, including alcohols, aldehydes, esters, ketones, norisoprenoids, terpenic, nitrogen and sulphur compounds, totalizing 38 and 41 compounds in leaves and root essential oils, respectively. Nitrogen compounds were the main volatiles in leaves essential oils and sulphur compounds were the main volatiles in root essential oils. Qualitative and quantitative differences were found among B. rapa var. rapifera parts essential oils collected from different locations and extracted by hydrodistillation and microwave-assisted hydrodistillation techniques. Furthermore, our findings showed a high variability for both antioxidant and antimicrobial activities. The highlighted variability reflects the high impact of plant part, geographic variation and extraction technique on chemical composition and biological activities, which led to conclude that we should select essential oils to be investigated carefully depending on these factors, in order to isolate the bioactive components or to have the best quality of essential oil in terms of biological activities and preventive effects in food. © 2017 Wiley-VHCA AG, Zurich, Switzerland.

  4. Solvent extraction

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, D.M.; Latimer, E.G.

    1988-01-05

    It is an object of this invention to provide for the demetallization and general upgrading of heavy oil via a solvent extracton process, and to improve the efficiency of solvent extraction operations. The yield and demetallization of product oil form heavy high-metal content oil is maximized by solvent extractions which employ either or all of the following techniques: premixing of a minor amount of the solvent with feed and using countercurrent flow for the remaining solvent; use of certain solvent/free ratios; use of segmental baffle tray extraction column internals and the proper extraction column residence time. The solvent premix/countercurrent flow feature of the invention substantially improves extractions where temperatures and pressures above the critical point of the solvent are used. By using this technique, a greater yield of extract oil can be obtained at the same metals content or a lower metals-containing extract oil product can be obtained at the same yield. Furthermore, the premixing of part of the solvent with the feed before countercurrent extraction gives high extract oil yields and high quality demetallization. The solvent/feed ratio features of the invention substanially lower the captial and operating costs for such processes while not suffering a loss in selectivity for metals rejection. The column internals and rsidence time features of the invention further improve the extractor metals rejection at a constant yield or allow for an increase in extract oil yield at a constant extract oil metals content. 13 figs., 3 tabs.

  5. Radioanalytical determination of plutonium and americium using ion exchange and extraction chromatography technique in urine

    International Nuclear Information System (INIS)

    Santhanakrishnan, V.; Sreedevi, K.R.; Rajaram, S.; Ravi, P.M.

    2011-01-01

    The use of anion exchange chromatography for the separation of Pu and extraction chromatography technique for the separation of Am from urine samples was studied. In the earlier method, Pu separation was carried out by anion exchange chromatography followed by Am separation by cation exchange chromatography. The chemical recovery of Am obtained by cation exchange separation method was inconsistent and low in the range 30-70%. In this study, the average Pu recovery obtained using anion exchange chromatography was 89.2 with standard deviation of 10.4 and the average Am recovery obtained using extraction chromatography with TRU resin was 77.4 with standard deviation of 14.8. Moreover, Am separation could be completed within three hours using the TRU column compared to two days that were required for the cation exchange chromatography. (author)

  6. A methodology for automated CPA extraction using liver biopsy image analysis and machine learning techniques.

    Science.gov (United States)

    Tsipouras, Markos G; Giannakeas, Nikolaos; Tzallas, Alexandros T; Tsianou, Zoe E; Manousou, Pinelopi; Hall, Andrew; Tsoulos, Ioannis; Tsianos, Epameinondas

    2017-03-01

    Collagen proportional area (CPA) extraction in liver biopsy images provides the degree of fibrosis expansion in liver tissue, which is the most characteristic histological alteration in hepatitis C virus (HCV). Assessment of the fibrotic tissue is currently based on semiquantitative staging scores such as Ishak and Metavir. Since its introduction as a fibrotic tissue assessment technique, CPA calculation based on image analysis techniques has proven to be more accurate than semiquantitative scores. However, CPA has yet to reach everyday clinical practice, since the lack of standardized and robust methods for computerized image analysis for CPA assessment have proven to be a major limitation. The current work introduces a three-stage fully automated methodology for CPA extraction based on machine learning techniques. Specifically, clustering algorithms have been employed for background-tissue separation, as well as for fibrosis detection in liver tissue regions, in the first and the third stage of the methodology, respectively. Due to the existence of several types of tissue regions in the image (such as blood clots, muscle tissue, structural collagen, etc.), classification algorithms have been employed to identify liver tissue regions and exclude all other non-liver tissue regions from CPA computation. For the evaluation of the methodology, 79 liver biopsy images have been employed, obtaining 1.31% mean absolute CPA error, with 0.923 concordance correlation coefficient. The proposed methodology is designed to (i) avoid manual threshold-based and region selection processes, widely used in similar approaches presented in the literature, and (ii) minimize CPA calculation time. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Investigation of soil erosion in arable land in Hungary using radiotracer technique

    International Nuclear Information System (INIS)

    Dezsoe, Z.; Szabo, Sz.

    2004-01-01

    Quantitative data on long-term soil erosion rates on agricultural land are an essential requirement for the development of effective soil management and conservation strategies. Although several methods to estimate soil erosion exist, the use of 137 Cs and/or 210 Pb as fallout radionuclides for tracing soil movement overcomes many of the limitations of the traditional methods. Recently, the 137 Cs-technique has been widely accepted and is now commonly used for estimating the magnitude of soil loss. Long-term migration of 137 Cs in the Buekkzserc-Cserepfalu-Bogacs triangle area, at the foot of Buekk mountain (NE Hungary) was studied. The samples were analysed for 137 Cs by gamma spectrometry, using a calibrated high-resolution, low background HPGe coaxial detector. Migration of fallout nuclides in an undisturbed stable soil reflects the influence of a range of physico-chemical and biological processes operating in the soil system. (N.T.)

  8. Hyphenated chromatographic techniques for the rapid screening and identification of antioxidants in methanolic extracts of pharmaceutically used plants .

    NARCIS (Netherlands)

    Exarchou, V.; Fiamegos, Y.C.; Beek, van T.A.; Nanos, C.G.; Vervoort, J.J.M.

    2006-01-01

    Phytochemical analysis is an important scientific research area, which normally relies on a number of rather laborious and time-consuming techniques for compound identification. Isolation of the ingredients of plant extracts in adequate quantities for spectral and biological analysis was the basis

  9. TO THE QUESTION ON THE CHOICE OF RADIOTRACER FOR THE DINAMIC NEPHROSCINTIGRAPHY WITH FUNCTIONAL TESTS

    Directory of Open Access Journals (Sweden)

    D.K. Fomin

    2008-01-01

    Full Text Available The comparison of quality of the images at various stages complex dynamic nephroscintigraphy of the urinary tract received with use of various types of radiotracers. To all patients has been executed dynamic nephroscintigraphy with orthostatic sign and indirect radionuclide cystography, also the analysis of quality of images is lead by a method of expert estimations. It was established, that the best opportunities of a visual estimation of a condition of collective system of kidneys and ureters are provided with application tubular radiotraceres, and for an estimation parenchymatous phases of research — glomerular traceres.Key words: vesicoureteral reflux, secretory function of kidneys, excretory function of kidneys, dinamic scintigraphy, radionuclide cystography.

  10. Radiotracer investigation of phosphoric acid and phosphatic fertilizers production process

    International Nuclear Information System (INIS)

    Ben Abdelouahed, H.; Reguigui, N.

    2011-01-01

    In the phosphoric acid production process, the time a particle spends inside the chemical reactor (residence time) is of paramount importance to process engineers. Residence time distribution (RTD) gives information on the efficiency of the chemical reactor, on the efficiency of the process, and also the availabilities of the reactive volume for the reaction (active volume vs. dead volume). Traditionally, chemical engineers used chemical tracer to determine the RTD. However, first disadvantage is that the chemical tracer could not allow an online diagnosis: the samples containing chemical tracer have to go to a lab for analysis, second disadvantage is that the chemical tracer is less sensitive than radioactive ones because of its adsorption onto strata or its retention in rocks. Consequently, chemical tracer results are not always precise and cannot convincingly explain the multiple flow-path model. Radioactive tracers are the only tracers capable of measuring the active RTD with high degree of precision and give information on the internal recirculation rate. In this work, we will describe the application of radiotracer method for RTD measurement in the phosphoric acid production process and give results and discussion of each case encountered. (author)

  11. Characterization of Arachis hypogaea L. oil obtained from different extraction techniques and in vitro antioxidant potential of supercritical fluid extraction extract

    Directory of Open Access Journals (Sweden)

    Rishika Chauhan

    2016-01-01

    Full Text Available Aim: The present investigation was aimed to characterize the fixed oil of Arachis hypogaea L. using five different extraction methods: Supercritical fluid extraction (SFE, ultrasound assistance extraction, soxhlet extraction, solvent extraction, and three phase partitioning method. Materials and Methods: The SFE conditions (temperature, pressure, and volume of CO 2 were optimized prior for better yield. The extracted oils were analyzed and compared for their physiochemical parameters, high-performance thin layer chromatography (HPTLC, gas chromatography-mass spectrometry (GC-MS, and Fourier transform infrared spectrometry (FT-IR fingerprinting. Anti-oxidant activity was also determined using DPPH and superoxide scavenging method. Results: The main fatty acids were oleic, linoleic, palmitic, and stearic acids as obtained by GC-MS. HPTLC analysis revealed the presence of similar major components in chromatograms. Similarly, the pattern of peaks as obtained in FT-IR and GC-MS spectra of same oils by different extraction methods was superimposable. Conclusion: Analysis reported that the fixed oil of A. hypogaea L. is a good source of unsaturated fatty acid, mainly n-6 and n-9 fatty acid with a significant antioxidant activity of oil obtained from SFE extraction method.

  12. Combined Cataract Extraction With Pars Plana Vitrectomy and Metallic Intraocular Foreign Body Removal Through Sclerocorneal Tunnel Using a Novel "Magnet Handshake" Technique.

    Science.gov (United States)

    Dhoble, Pankaja; Khodifad, Ashish

    2018-01-01

    To study the outcomes of combined cataract extraction with pars plana vitrectomy (PPV) and metallic intraocular foreign body (IOFB) removal through a sclerocorneal tunnel using the "magnetic handshake" technique. A retrospective review. Retrospective review of case records of 14 patients from 2010 to 2016 with metallic IOFB and traumatic cataract was performed. Cataract extraction was combined with PPV. Two intraocular magnets (IOMs) introduced through 20-gauge vitrectomy port and sclerocorneal tunnel helped achieve safe delivery of IOFB outside the globe by the "magnetic handshake" technique. All patients were males with a mean age of 33.04 years. A final best corrected visual acuity (BCVA) of 20/60 or better was noted in 10 (71.42%) of 14 patients. Final reattachment with more than 1 surgery was achieved in 13 (92.85%) patients. Postoperative complications included retinal detachment (RD) and phthisis bulbi in 1 (14.28%) patient each. Combined cataract extraction with PPV and metallic IOFB removal through sclerocorneal tunnel using the "magnet handshake" technique gives good visual and surgical outcomes. Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  13. Flow Rate Measurement Using 99mTc Radiotracer Method in a Pipe Installation

    International Nuclear Information System (INIS)

    Sipaun, S. M.; Bakar, A. Q. Abu; Othman, N.; Shaari, M. R.; Adnan, M. A. K.; Yusof, J. Mohd; Demanah, R.

    2010-01-01

    Flow rate is a significant parameter for managing processes in chemical processing plants and water processing facility. Accurate measurement of the flow rate allows engineers to monitor the delivery of process material, which in turn impacts a plant's capacity to produce their products. One of the available methods for determining the flow rate of a process material is by introducing a radiotracer to the system that mimics the material's flow pattern. In this study, a low activity Technetium-99m radioisotope was injected into a water piping setup and the 2'' x 2'' NaI (Tl) detectors were calibrated to detect spectrum peaks at specific points of the pipe installation. Using pulse velocity method, water flow rate was determined to be 11.3 litres per minute. For the sampling method, at different pump capacity, the flow rate was 15.0 litres per minute.

  14. Assessment of chromium biostabilization in contaminated soils using standard leaching and sequential extraction techniques

    International Nuclear Information System (INIS)

    Papassiopi, Nymphodora; Kontoyianni, Athina; Vaxevanidou, Katerina; Xenidis, Anthimos

    2009-01-01

    The iron reducing microorganism Desulfuromonas palmitatis was evaluated as potential biostabilization agent for the remediation of chromate contaminated soils. D. palmitatis were used for the treatment of soil samples artificially contaminated with Cr(VI) at two levels, i.e. 200 and 500 mg kg -1 . The efficiency of the treatment was evaluated by applying several standard extraction techniques on the soil samples before and after treatment, such as the EN12457 standard leaching test, the US EPA 3060A alkaline digestion method and the BCR sequential extraction procedure. The water soluble chromium as evaluated with the EN leaching test, was found to decrease after the biostabilization treatment from 13 to less than 0.5 mg kg -1 and from 120 to 5.6 mg kg -1 for the soil samples contaminated with 200 and 500 mg Cr(VI) per kg soil respectively. The BCR sequential extraction scheme, although not providing accurate estimates about the initial chromium speciation in contaminated soils, proved to be a useful tool for monitoring the relative changes in element partitioning, as a consequence of the stabilization treatment. After bioreduction, the percentage of chromium retained in the two least soluble BCR fractions, i.e. the 'oxidizable' and 'residual' fractions, increased from 54 and 73% to more than 96% in both soils

  15. Assessment of phacoaspiration techniques in clear lens extraction for correction of high myopia

    Directory of Open Access Journals (Sweden)

    Mostafa A El-Helw

    2010-03-01

    Full Text Available Mostafa A El-Helw, Ahmed M EmarahDepartment of Ophthalmology, Cairo University, EgyptPurpose: To evaluate various phacoaspiration techniques in clear lens extraction for the incidence of intraoperative difficulties and complications.Patients and methods: This was a prospective study in which bilateral clear lens extraction was performed on 40 eyes of 20 patients, to correct high myopia. The patients were divided into 2 groups: group A underwent supracapsular phacoaspiration; group B were the contralateral eyes of the same patient. These patients were operated on with endocapsular phacoaspiration with the divide and conquer (D and C technique. Preoperative ocular examination data were recorded and tested for significance. Intraoperative difficulties and complications such as nucleus cracking, capsule rupture and vitreous loss, and repeated chamber collapse were recorded. Postoperative examination data were recorded.Results: Mean age was 35.65 ± 5.85 years. Mean follow-up time was 17.1 ± 8.56 months. In group A mean myopia was -17.3 ± 5.07 diopters; in group B myopia was -17.9 ± 4.20 diopters. Mean preoperative uncorrected visual acuity (UCVA was 0.04 ± 0.0167, while the mean postoperative UCVA was 0.435 ± 0.1442. There was a significant difference in pre and postoperative BCVA within both groups, but not between the two groups. In both groups endothelial cell count (ECC showed a significant difference between pre- and postoperative data; however, there was no statistically significant difference between both groups in postoperative ECC. The effective phacoaspiration time for group A was 4.6 ± 1.6 seconds, and for group B 9.90 ± 2.27 seconds (P < 0.005. No cases of capsule rupture occurred in group A, but 3 cases occurred in group B (15 % (not significant, P = 0.231. Nucleus cracking did not occur in group A, but in group B 13 cases occurred (65%. Chamber collapse occurred in 4 cases (20% in group A and 5 cases (25% in group B (not

  16. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    Science.gov (United States)

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    of (99m)Tc-HMPAO with the dual tracer in normal mice also were the similar to those of the (99m)Tc-HMPAO single injection. In the first injection of (123)I-FP-CIT and second injection of (99m)Tc-HMPAO, the brain images and radioactive counts with the dual tracer were not much different from those of the (123)I-FP-CIT single injection. Dual-tracer imaging of (99m)Tc- and (123)I-labeled radiotracers is feasible in a preclinical SPECT scanner with CZT detector. When higher radioactivity of (99m)Tc-labeled radiotracers relative to (123)I-labeled radiotracers is applied, correction methods are not necessarily required for the quantification of (99m)Tc- and (123)I-labeled radiotracers when using a preclinical SPECT scanner with CZT detector.

  17. Stability of Anthocyanins from Red Grape Skins under Pressurized Liquid Extraction and Ultrasound-Assisted Extraction Conditions

    Directory of Open Access Journals (Sweden)

    Ali Liazid

    2014-12-01

    Full Text Available The stability of anthocyanins from grape skins after applying different extraction techniques has been determined. The following compounds, previously extracted from real samples, were assessed: delphinidin 3-glucoside, cyanidin 3-glucoside, petunidin 3-glucoside, peonidin 3-glucoside, malvidin 3-glucoside, peonidin 3-acetylglucoside, malvidin 3-acetylglucoside, malvidin 3-caffeoylglucoside, petunidin 3-p-coumaroylglucoside and malvidin 3-p-coumaroylglucoside (trans. The techniques used were ultrasound-assisted extraction and pressurized liquid extraction. In ultrasound-assisted extraction, temperatures up to 75 °C can be applied without degradation of the aforementioned compounds. In pressurized liquid extraction the anthocyanins were found to be stable up to 100 °C. The relative stabilities of both the glycosidic and acylated forms were evaluated. Acylated derivatives were more stable than non-acylated forms. The differences between the two groups of compounds became more marked on working at higher temperatures and on using extraction techniques with higher levels of oxygen in the extraction media.

  18. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  19. Radionuclide techniques in criminology. II

    International Nuclear Information System (INIS)

    Stverak, B.; Kopejtko, J.

    1979-01-01

    A radiotracer method was developed and tested for the age determination of manuscripts. The method is based on the autoradiographic detection of chloride ions migration from inks and on the use of insoluble sup(110m)AgCl formation. (author)

  20. Extraction of functional ingredients from spinach (Spinacia oleracea L.) using liquid solvent and supercritical CO₂ extraction.

    Science.gov (United States)

    Jaime, Laura; Vázquez, Erika; Fornari, Tiziana; López-Hazas, María del Carmen; García-Risco, Mónica R; Santoyo, Susana; Reglero, Guillermo

    2015-03-15

    In this work three different techniques were applied to extract dry leaves of spinach (Spinacia oleracea): solid-liquid extraction (SLE), pressurised liquid extraction (PLE) and supercritical fluid extraction (SFE) to investigate the influence of extraction solvent and technique on extracts composition and antioxidant activity. Moreover, the influence of carotenoids and phenolic compounds on the antioxidant and anti-inflammatory activities of spinach extracts was also studied. The higher concentrations of carotenoids and the lower content of phenolic compounds were observed in the supercritical CO₂ extracts; whereas water and/or ethanol PLE extracts presented low amounts of carotenoids and the higher concentrations of phenolic compounds. PLE extract with the highest content of phenolic compounds showed the highest antioxidant activity, although SFE carotenoid rich extract also showed a high antioxidant activity. Moreover, both extracts presented an important anti-inflammatory activity. PLE seems to be a good technique for the extraction of antioxidant and anti-inflammatory compounds from spinach leaves. Moreover, spinach phenolic compounds and carotenoids present a high antioxidant activity, whereas spinach carotenoids seem to show a higher anti-inflammatory activity than phenolic compounds. It is worth noting that of our knowledge this is the first time the anti-inflammatory activity of lipophilic extracts from spinach leaves is reported. © 2014 Society of Chemical Industry.