WorldWideScience

Sample records for extinguishing systems details

  1. 29 CFR 1910.161 - Fixed extinguishing systems, dry chemical.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Fixed extinguishing systems, dry chemical. 1910.161 Section... § 1910.161 Fixed extinguishing systems, dry chemical. (a) Scope and application. This section applies to all fixed extinguishing systems, using dry chemical as the extinguishing agent, installed to meet a...

  2. Fire extinguishing system in large underground garages

    Directory of Open Access Journals (Sweden)

    Ivan Antonov

    2017-04-01

    Full Text Available In the work is considered an acceptable constructive scheme from a practical point of view at fire extinguishing in underground garages. The garage space is divided into quadrants which covering, for example, 2 cars. In case of ignition on one of them, a sprinkler nozzle system is triggered by the effect of the vertical convective jet. A protective curtain preventing the spread of fire to adjacent vehicles is realized. The solution is based on an integrated method which allows the calculation from hydrodynamic point of view on extinguishing time of the fire extinguishing system.

  3. Introduction of Sodium Fire Extinguishing System for STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective.

  4. Introduction of Sodium Fire Extinguishing System for STELLA-1

    International Nuclear Information System (INIS)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung

    2015-01-01

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective

  5. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Fixed extinguishing systems, water spray and foam. 1910.163... Suppression Equipment § 1910.163 Fixed extinguishing systems, water spray and foam. (a) Scope and application. This section applies to all fixed extinguishing systems, using water or foam solution as the...

  6. Liquid nitrogen fire extinguishing system test report

    International Nuclear Information System (INIS)

    Beidelman, J.A.

    1972-01-01

    The objective of this test series was to demonstrate the feasibility of using liquid nitrogen as a fire-extinguishing agent for certain types of metal fires. It was intended to provide data and experience appropriate to the design of a second series which will test the applicability of this technique to plutonium fires and which will develop more detailed operating information and permit more precise measurement of test parameters-oxygen depletion rates and equilibrium concentrations, temperature effects, and nitrogen pressures, flow rates, spray methods and patterns, etc. The test series was directed specifically toward extinguishment of metal fires occurring in well-confined areas and was not intended to be representative of any larger classification. Fires of several types were tested, e.g., magnesium, mixed magnesium and zirconium, sodium and cerium

  7. Extinguishing agent for magnesium fire, phases 5 and 6

    Science.gov (United States)

    Beeson, H. D.; Tapscott, R. E.; Mason, B. E.

    1987-07-01

    This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases 1 to 4. The results of this validation testing form the basis of information from which draft military specifications necessary to procure the agent and the agent delivery system may be developed. The developed system was tested against a variety of large-scale metal fire scenarios and the capabilities of the system were assessed. In addition the response of the system to storage and to changes in ambient conditions was tested. Results of this testing revealed that the developed system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires. The specifications developed for the agent and for the delivery system are discussed in detail.

  8. 46 CFR 167.45-1 - Steam, carbon dioxide, and halon fire extinguishing systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Steam, carbon dioxide, and halon fire extinguishing....45-1 Steam, carbon dioxide, and halon fire extinguishing systems. (a) General requirements. (1...-extinguishing system. On such vessels contracted for prior to January 1, 1962, a steam smothering system may be...

  9. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    Science.gov (United States)

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  10. Fire extinguishing device for nuclear power plant

    International Nuclear Information System (INIS)

    Arakawa, Ken

    1990-01-01

    Fire extinguishing pipelines disposed in turbine buildings of low earthquake proof grade and fire extinguishing pipelines disposed in reactor buildings of high earthquakes proof grade have been used in common with each other. Accordingly, if the fire extinguishing device in the turbine buildings designed for low earthquake proof grade are partially destroyed upon occurrence of medium-scale earthquakes, there is a worry that fire extinguishing water can not be supplied to the inside of the reactor buildings. In view of the above, an emergency fire extinguishing water system using a fire extinguishing reservoir at the outdoor of low earthquake proof grade as a feedwater source and suitable to the low earthquake proof grade is disposed in the turbine buildings. Another emergency fire extinguishing water system using an emergency fire extinguishing water reservoir disposed in the reactor buildings as a feedwater source and suitable to the high earthquake proof grade is disposed in the reactor buildings. Then, ordinary fire extinguishing water system and the emergency fire extinguishing water system are connected to each other. Thus, upon occurrence of earthquakes if the function of the ordinary fire extinguishing water system of low earthquake proof grade is lost, fires breaking out in the reactor buildings can rapidly be extinguished. (N.H.)

  11. Planning an Automatic Fire Detection, Alarm, and Extinguishing System for Research Laboratories

    Directory of Open Access Journals (Sweden)

    Rostam Golmohamadi

    2014-04-01

    Full Text Available Background & Objectives: Educational and research laboratories in universities have a high risk of fire, because they have a variety of materials and equipment. The aim of this study was to provide a technical plan for safety improvement in educational and research laboratories of a university based on the design of automatic detection, alarm, and extinguishing systems . Methods : In this study, fire risk assessment was performed based on the standard of Military Risk Assessment method (MIL-STD-882. For all laboratories, detection and fire alarm systems and optimal fixed fire extinguishing systems were designed. Results : Maximum and minimum risks of fire were in chemical water and wastewater (81.2% and physical agents (62.5% laboratories, respectively. For studied laboratories, we designed fire detection systems based on heat and smoke detectors. Also in these places, fire-extinguishing systems based on CO2 were designed . Conclusion : Due to high risk of fire in studied laboratories, the best control method for fire prevention and protection based on special features of these laboratories is using automatic detection, warning and fire extinguishing systems using CO2 .

  12. Analysis of the Earthquake Impact towards water-based fire extinguishing system

    Science.gov (United States)

    Lee, J.; Hur, M.; Lee, K.

    2015-09-01

    Recently, extinguishing system installed in the building when the earthquake occurred at a separate performance requirements. Before the building collapsed during the earthquake, as a function to maintain a fire extinguishing. In particular, the automatic sprinkler fire extinguishing equipment, such as after a massive earthquake without damage to piping also must maintain confidentiality. In this study, an experiment installed in the building during the earthquake, the water-based fire extinguishing saw grasp the impact of the pipe. Experimental structures for water-based fire extinguishing seismic construction step by step, and then applied to the seismic experiment, the building appears in the extinguishing of the earthquake response of the pipe was measured. Construction of acceleration caused by vibration being added to the size and the size of the displacement is measured and compared with the data response of the pipe from the table, thereby extinguishing water piping need to enhance the seismic analysis. Define the seismic design category (SDC) for the four groups in the building structure with seismic criteria (KBC2009) designed according to the importance of the group and earthquake seismic intensity. The event of a real earthquake seismic analysis of Category A and Category B for the seismic design of buildings, the current fire-fighting facilities could have also determined that the seismic performance. In the case of seismic design categories C and D are installed in buildings to preserve the function of extinguishing the required level of seismic retrofit design is determined.

  13. Literature study regarding fire protection in nuclear power plants. Part 2: Fire detection and -extinguishing systems

    International Nuclear Information System (INIS)

    Isaksson, S.

    1996-01-01

    This literature study has been made on behalf of the Swedish Nuclear Power Inspectorate. The aim is to describe different aspects of fire protection in nuclear power plants. Detection and extinguishing systems in Swedish nuclear power plants have only to a limited extent been designed after functional demands, such as a maximum acceptable damage or a maximum time to detect a fire. The availability of detection systems is difficult to assess, partly because of lack of statistics. The user interface is very important in complex systems as nuclear plants. An extinguishing system designed according to the insurance companies' regulations will only fulfill the basic demands. It should be noted that normal sprinkler design does not aim for extinguishing fires, the objective is to control fire until manual extinguishment is possible. There is a great amount of statistics on wet and dry pipe sprinkler systems, while statistics are more scarce for deluge systems. The statistics on the reliability of gaseous extinguishing systems have been found very scarce. A drawback of these systems is that they are normally designed for one shot only. There are both traditional and more recent extinguishing systems that can replace halons. From now on there will be a greater need for a thorough examination of the properties needed for the individual application and a quantification of the acceptable damage. There are several indications on the importance of a high quality maintenance program as well as carefully developed routines for testing and surveillance to ensure the reliability of detection and extinguishing systems. 78 refs, 8 figs, 10 tabs

  14. HOT AEROSOL FIRE EXTINGUISHING AGENTS AND THE ASSOCIATED TECHNOLOGIES: A REVIEW

    Directory of Open Access Journals (Sweden)

    Xiaotian Zhang

    2015-09-01

    Full Text Available AbstractSince the phase out of Halon extinguishers in the 1980s, hot aerosol fire suppression technology has gained much attention. Unlike traditional inert gas, foam, water mist and Halon fire suppression agents, hot aerosol fire extinguishing agents do not need to be driven out by pressurized gases and can extinguish class A, B, C, D and K fires at 30 to 200 g/m3. Generally, hot aerosol fire extinguishing technology has developed from a generation I oil tank suppression system to a generation III strontium salt based S-type system. S-type hot aerosol fire extinguishing technology greatly solves the corrosion problem of electrical devices and electronics compared to potassium salt based generation I & II hot aerosol fire extinguishing technology. As substitutes for Halon agents, the ODP and GWP values of hot fire extinguishing aerosols are nearly zero, but those fine aerosol particles can cause adverse health effects once inhaled by human. As for configurations of hot aerosol fire extinguishing devices, fixed or portable cylindrical canisters are the most common among generation II & III hot aerosol fire extinguishers across the world, while generation I hot aerosol fire suppression systems are integrated with the oil tank as a whole. Some countries like the U.S., Australia, Russia and China, etc. have already developed standards for manufacturing and quality control of hot aerosol fire extinguishing agents and norms for hot aerosol fire extinguishing system design under different fire protection scenarios. Coolants in hot aerosol fire suppression systems, which are responsible for reducing hot aerosol temperature to avoid secondary fire risk are reviewed for the first time. Cooling effects are generally achieved through vaporization and endothermic chemical decomposition of coolants. Finally, this review discussed areas applying generation I, II or III hot aerosol fire suppression technologies. The generation III hot aerosol fire extinguishing

  15. Radio frequency security system, method for a building facility or the like, and apparatus and methods for remotely monitoring the status of fire extinguishers

    Science.gov (United States)

    Runyon, Larry [Richland, WA; Gunter, Wayne M [Richland, WA; Gilbert, Ronald W [Gilroy, CA

    2006-07-25

    A system for remotely monitoring the status of one or more fire extinguishers includes means for sensing at least one parameter of each of the fire extinguishers; means for selectively transmitting the sensed parameters along with information identifying the fire extinguishers from which the parameters were sensed; and means for receiving the sensed parameters and identifying information for the fire extinguisher or extinguishers at a common location. Other systems and methods for remotely monitoring the status of multiple fire extinguishers are also provided.

  16. Counting addressing method: Command addressable element and extinguishing module

    Directory of Open Access Journals (Sweden)

    Ristić Jovan D.

    2009-01-01

    Full Text Available The specific requirements that appear in addressable fire detection and alarm systems and the shortcomings of the existing addressing methods were discussed. A new method of addressing of detectors was proposed. The basic principles of addressing and responding of a called element are stated. Extinguishing module is specific subsystem in classic fire detection and alarm systems. Appearing of addressable fire detection and alarm systems didn't caused essential change in the concept of extinguishing module because of long calling period of such systems. Addressable fire security system based on counting addressing method reaches high calling rates and enables integrating of the extinguishing module in addressable system. Solutions for command addressable element and integrated extinguishing module are given in this paper. The counting addressing method was developed for specific requirements in fire detection and alarm systems, yet its speed and reliability justifies its use in the acquisition of data on slowly variable parameters under industrial conditions. .

  17. 'In situ' expanded graphite extinguishant

    International Nuclear Information System (INIS)

    Cao Qixin; Shou Yuemei; He Bangrong

    1987-01-01

    This report is concerning the development of the extinguishant for sodium fire and the investigation of its extinguishing property. The experiment result shows that 'in situ' expanded graphite developed by the authors is a kind of extinguishant which extinguishes sodium fire quickly and effectively and has no environment pollution during use and the amount of usage is little

  18. New on-board extinguisher system on diesel-driven vehicles in the German underground coal mining industry; Neuartige bordfeste Loeschanlage auf dieselgetriebenen Fahrzeugen im untertaegigen deutschen Steinkohlenbergbau

    Energy Technology Data Exchange (ETDEWEB)

    Fetting, Dieter; Alze, Matthias [Bergwerk Ost, Hamm (Germany); Cerny, Udo [RAG Deutsche Steinkohle AG, Herne (Germany). Hauptstelle fuer das Grubenrettungswesen

    2010-01-15

    A new extinguisher system has been developed by protectfire Brandschutztechnik GmbH and has now been approved for use in underground mines. This extinguisher system is interesting by virtue of its reliability (no faulty tripping e.g. by defective electrical components is possible) and it's extinguishing efficiency (significantly longer extinguishing time compared to a powder extinguisher). No outside energy source is required for operation of the extinguisher. The motor is stopped more quickly by connection of the motor shutdown valve in the exciter line. Economic considerations - easier maintenance and lower costs compared to similar systems - also make this system interesting. (orig.)

  19. Extinguisher powder for liquid metal fires

    Energy Technology Data Exchange (ETDEWEB)

    Menzenhauer, P; Ochs, G [Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorentwicklung

    1978-11-01

    The extinguisher introduced here based on graphite exhibited considerably improved extinguishing properties compared to other extinguishing powders. It has no aggressive properties, is, as for as could be tested in the short time available, non-hygroscopic and thus very easy to remove after extinguishing and cooling of the fire. The amount of extinguisher necessary is only a fraction of the amounts needed of other common powders. Storage is no problem and nerely a small storage amount is required. This extinguisher is excellently suitable for fighting sodium surface fires.

  20. Extinguisher powder for liquid metal fires

    International Nuclear Information System (INIS)

    Menzenhauer, P.; Ochs, G.

    1978-01-01

    The extinguisher introduced here based on graphite exhibited considerably improved extinguishing properties compared to other extinguishing powders. It has no aggressive properties, is, as for as could be tested in the short time available, non-hygroscopic and thus very easy to remove after extinguishing and cooling of the fire. The amount of extinguisher necessary is only a fraction of the amounts needed of other common powders. Storage is no problem and nerely a small storage amount is required. This extinguisher is excellently suitable for fighting sodium surface fires. (orig./HP) [de

  1. Oil well fire extinguisher having upper and lower external flame retardant-dispersing rings

    International Nuclear Information System (INIS)

    Kim, H.S.

    1992-01-01

    This patent describes an extinguisher system for extinguishing flames from combustible fluid exiting from a pipe. It comprises an elongated tubular extinguisher body disposable over the combustible fluid emitting pipe; valve means mounted in the extinguisher body adjacent the upper outlet end for eliminating the flow of the combustion

  2. 46 CFR 169.567 - Portable extinguishers.

    Science.gov (United States)

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS... permit the use of any approved fire extinguishers, including semiportable extinguishers, which provide equivalent fire protection. (c) All portable fire extinguishers installed on vessels must be of an approved...

  3. Process and fire extinguishing system for inflammable liquids

    International Nuclear Information System (INIS)

    Levillain, C.

    1988-01-01

    A fire on the surface of a flammable liquid is extinguished by spreading a compact layer of sphere of uniform diameter, floating on the liquid surface. Spheres are stored in a tank and run out by gravity [fr

  4. Methods to Compose Sodium Fire Extinguishing Equipment on Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B H; Kim, J M; Jeong, J Y; Choi, B H

    2008-06-15

    Sodium fire is graded 'D' and it is difficult to extinguish sodium fire. In this report, the characteristics of sodium fire and the methods composing the suitable fire extinguishing systems to suppress fire effectively were described.

  5. Methods to Compose Sodium Fire Extinguishing Equipment on Sodium Test Facility

    International Nuclear Information System (INIS)

    Kim, B. H.; Kim, J. M.; Jeong, J. Y.; Choi, B. H.

    2008-06-01

    Sodium fire is graded 'D' and it is difficult to extinguish sodium fire. In this report, the characteristics of sodium fire and the methods composing the suitable fire extinguishing systems to suppress fire effectively were described

  6. 14 CFR 29.1199 - Extinguishing agent containers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Extinguishing agent containers. 29.1199....1199 Extinguishing agent containers. (a) Each extinguishing agent container must have a pressure relief to prevent bursting of the container by excessive internal pressures. (b) The discharge end of each...

  7. 14 CFR 25.1199 - Extinguishing agent containers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Extinguishing agent containers. 25.1199....1199 Extinguishing agent containers. (a) Each extinguishing agent container must have a pressure relief to prevent bursting of the container by excessive internal pressures. (b) The discharge end of each...

  8. 14 CFR 23.1199 - Extinguishing agent containers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Extinguishing agent containers. 23.1199... Powerplant Fire Protection § 23.1199 Extinguishing agent containers. For commuter category airplanes, the following applies: (a) Each extinguishing agent container must have a pressure relief to prevent bursting of...

  9. Class B Fire-Extinguishing Performance Evaluation of a Compressed Air Foam System at Different Air-to-Aqueous Foam Solution Mixing Ratios

    Directory of Open Access Journals (Sweden)

    Dong-Ho Rie

    2016-06-01

    Full Text Available The purpose of this research is to evaluate the fire-extinguishing performance of a compressed air foam system at different mixing ratios of pressurized air. In this system, compressed air is injected into an aqueous solution of foam and then discharged. The experimental device uses an exclusive fire-extinguishing technology with compressed air foam that is produced based on the Canada National Laboratory and UL (Underwriters Laboratories 162 standards, with a 20-unit oil fire model (Class B applied as the fire extinguisher. Compressed air is injected through the air mixture, and results with different air-to-aqueous solution foam ratios of 1:4, 1:7, and 1:10 are studied. In addition, comparison experiments between synthetic surfactant foam and a foam type which forms an aqueous film are carried out at an air-to-aqueous solution foam ratio of 1:4. From the experimental results, at identical discharging flows, it was found that the fire-extinguishing effect of the aqueous film-forming foam is greatest at an air-to-aqueous solution foam ratio of 1:7 and weakest at 1:10. Moreover, the fire-extinguishing effect of the aqueous film-forming foam in the comparison experiments between the aqueous film-forming foam and the synthetic surfactant foam is greatest.

  10. INCREASING EXTINGUISHING EFFECT OF WATER MIST BY ELEKTRIFICATION

    Directory of Open Access Journals (Sweden)

    Otto Dvořák

    2017-04-01

    Full Text Available This paper describes extinguishing experiments to verify the possibility of increasing the fire-extinguishing efficiency of low-, medium- and high-pressure water mist by its charging by the electric field of high DC voltage. The experimental results confirmed the effects of the electrical voltage, the configuration of electrodes (anode, cathode, the volumetric water flow rate, water pressure and the type of mist nozzle. Higher fire-extinguishing effect of electrically-charged water mist was shown by a shorter extinguishing time, a smaller volume of water to extinguish the fire and a higher percentage of successful extinguishing attempts. Benefit: faster and more efficient fire-fighting with a smaller risk of injury of persons and smaller subsequent damage in the protected space.

  11. 30 CFR 36.31 - Fire extinguisher.

    Science.gov (United States)

    2010-07-01

    ... Construction and Design Requirements § 36.31 Fire extinguisher. Each unit of mobile diesel-powered... an active charge of not less than 4 pounds. Pressurized dry chemical extinguishers shall contain an...

  12. Graphite-based extinguishants for liquid metal fires

    International Nuclear Information System (INIS)

    Simpson, J.M.; Gardener, N.J.L.

    1987-01-01

    Effective extinguishants for liquid alkali metal fires must be provided for all LMFBRs. Traditional sodium salt based extinguishants have disadvantages. An intercalation compound of graphite was identified as a possible alternative. Following successful tests on fires of up to 25 m 2 area the graphite based extinguishant has been introduced by the UKAEA at Dounreay. (author)

  13. Extinguishing experiments of sodium fires carried out by TNO

    International Nuclear Information System (INIS)

    Meijer, G.J.A.M.; Rulkens, W.H.

    1979-01-01

    For the collection of burning sodium from the components and pipes of the secondary circuit of SNR 300, spill-trays are foreseen which are connected to dump tanks. These spill-trays are covered with a sieve in order to reduce the flow of air to the sodium in the spill-tray and hence to reduce the burning rate. In order to further minimize the consequences of a large sodium fire for the components, the licensing authority required as a back-up the installation of a remotely operated distribution system by means of which an extinguishing powder can be sprayed upon the spill-trays. Experiments were carried out in which the effectiveness of different extinguishing powders in combination with the sieve covered spill-trays were tested in a comparative manner. Attention was paid to the question whether such a spray system would have also additional benefits in the case of smaller sodium leaks. To this purpose three commercially available extinguishing powders were tested, one on a sodium chloride, two on a carbonate base. Also the effectiveness of the sieves proper with respect to reducing the burning rate was tested without applying any extinguishing powders. Finally for a reference some tests were done on open spill-trays, i.e. spill-trays not covered with a sieve.The investigations which were carried out in 1976-1977 were limited to fire experiments, aspects of transport of the powder in the distribution system were not investigated

  14. New Agents for the Extinguishment of Magnesium Fires.

    Science.gov (United States)

    1978-04-01

    34 23 July 1942. German Patent 724,795. 8. Beythien, R., Wienhaus, H., and von Zehman, H., "Extinguish- ing Magnesium and Other Light Metal Fires ," 12...34Trimethoxyboroxine--An Extinguishing Agent for Metal Fires ," ACS Advances in Chemistry, No. 23, American Chemical Society, Washington, D.C. pp 158...13. Miyashima, Z., "Fire Extinguishing Agent," 7 October 1958. Japanese Patent 8,946. 14. Jenkner, H., "Extinguishing Metal Fires ," 12 September

  15. A system extinguishing a fire by insulating a liquid fuel

    International Nuclear Information System (INIS)

    Colome, Jacques; Duchene, Alain; Regnier, Jean.

    1975-01-01

    The invention refers to a system for quickly extinguishing a liquid fuel body on fire by insulating it completely from the ambient air. It applies particularly to the case of a high temperature liquid sodium sheet flowing accidentally from a circuit belonging to a fast neutron reactor. The system in question includes a lower receptacle for collecting the liquid fuel and a top cover shutting off the receptacle. This cover has inclined channels to take the liquid fuel flow and openings to allow this liquid through at the bottom end of the channels. These openings are closed by retractable shutters moving away under the pressure of the liquid in the channels and closing automatically after the liquid has flowed into the receptacle [fr

  16. Liquefied extinguishing agent discharge to an overpressure-sensitive enclosed volume

    Directory of Open Access Journals (Sweden)

    Hurda Lukáš

    2018-01-01

    Full Text Available The throttling of liquefied substances from high pressure vessels to an enclosed volume starting at atmospheric pressure is described in order to determine thermodynamic state of the extinguished room gaseous contents. Time dependent, 0D mathematical model is implemented describing the state inside the agent container, the isenthalpic throttling in the distribution system, agent vaporization and mixing with air. The agent is modelled as real gas. Other influences on the process including the heat transfer from selected solid parts inside the room and the gas mixture leakage out of the room are taken into account. Main outcome is an MS Excel tool for integrated fire extinguishers design optimization. The optimization balances the two contradictory requirements: Agent volumetric concentration to sustain the fire extinguishing capabilities and tolerable room overpressure. Agent fill weight and discharge time are being adjusted. The discharge time is controlled by the distribution piping and spray nozzles design. System operation is checked concerning various initial and boundary conditions.

  17. Process and device for extinguishing fires inside gloveboxes

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, P

    1975-01-09

    The present invention relates to a process of extinguishing all types of fire inside gloveboxes. Said process prevents the inner part of the box to communicate with the room atmosphere: the glove that is the nearest to the hearth of fire is perforated with an edged tip mounted on the outlet of the extinguisher and the product contained inside said extinguisher is released until the fire extinction is achieved. A device for operating said process consists in an edged tubular tip, the end of which is bevelled and in means of dispersion and of connection to an extinguisher at the other end.

  18. 46 CFR 181.410 - Fixed gas fire extinguishing systems.

    Science.gov (United States)

    2010-10-01

    ... less than 170 cubic meters (6000 cubic feet), release of an extinguishing agent into a space must... unoccupied space of less than 170 cubic meters (6,000 cubic feet) may have the storage cylinders located... between 16,550 and 19,300 kPa (2,400 and 2,800 psi) must be installed in the distribution manifold to...

  19. Optimization of extinguishing agents for nuclear power plants

    International Nuclear Information System (INIS)

    Boleman, M.; Lipar, M.; Balog, K.

    1998-01-01

    Focus is placed on use of extinguishing agents in nuclear power plants. The advantages and disadvantages of these agents are compared. Further perspectives for using particular extinguishing agents in nuclear power plants are outlined. (author)

  20. Development and Evaluation of a Prototype Wheeled Ultra-High Pressure Extinguisher System with Novec 1230

    Science.gov (United States)

    2016-01-01

    extinguisher containing the Novec 1230 firefighting agent manufactured by 3M. This effort expanded upon a previous evaluation of the Amerex Corporation model...Air Force Civil Engineer Center (AFCEC) performed a series of tests to evaluate the performance of the Amerex Corporation model 775 wheeled...Extinguishing Effectiveness Tests, McDonald , Michael J. et al. Defense Technical Information Center. AFRL-ML-TY-TR-2004-4554, October 2005. 9. F100

  1. Lab Fire Extinguishers: Here Today, Gone Tomorrow?

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    When renovations or new construction occur, fire extinguishers sometimes get lost in the mix. Unfortunately, whether to save money or because the fire code is misinterpreted, some schools do not install fire extinguishers in laboratories and other areas of the building. Let's set the record straight! If flammables are present, the fire code…

  2. Rationalization design on large equipment dismantling facility. The cell fire-extinguishing examination (3)

    International Nuclear Information System (INIS)

    Donomae, Yasushi; Matsumoto, Yoshihiro; Takita, Koji; Kikuchi, Yutaka; Katoh, Noriyoshi; Miyazaki, Hitoshi; Tanimoto, Ken-ichi

    2002-07-01

    In order to rationalize for Large Equipment Dismantling Facility (LEDF), the plan of removing vaporizer belong to Cell-fire-extinguishing-system was investigated. When a vaporizer is cut down, it is necessary to grasp a fire-extinguishing performance. The fire-extinguishing performance check examination by liquefaction carbon dioxide in the cell fire-extinguishing examination (I) was carried out in 1999 fiscal year. As the result, the good performance was obtained to polyethylene. But there was the deep-seated fire about a piece of wood. Then, the check items were carbon dioxide (CO2) concentration and CO2 concentration holding time for the deep-seated fire in the cell fire-extinguishing examination (III). The results were as follows; (1) By use of the combustion model in which a piece of wood and cotton were put is lit, temperature inside model, mass reduction, and combustion situation were examined. The model burned remarkably in 30∼60 min. The peak temperature rise to 680 degC (MAX), and attained smoldering after (ignition) 70 min. Moreover, in order to determine the generating conditions of a deep-seated fire, the situation of CO2 extinguishing after ignition by the time lag of 50∼90 min were examined. The model around ignition 50 minutes was the most difficult to extinguish, and it turned out that they are the conditions which were most suitable for the deep-seated fire examination model of an exam. (2) In order to decide on CO2 concentration and concentration holding time required for fire extinguishing of the deep-seated fire in LEDF, the fire-extinguishing performance was investigated by 40 ∼ 65% of CO2 concentration. Consequently, CO2 concentration required for deep-seated fire extinguishing was understood that 60% or more was required when safety was taken into consideration at 50% or more. Moreover, when it was 50% or more of CO2 concentration and the holding time of CO2 concentration was 180 minutes or more and 60% or more of CO2 concentration, it

  3. Fire extinguishing of electrical equipment under voltage at nuclear power plants

    International Nuclear Information System (INIS)

    Capek, Josef

    2009-01-01

    Fire extinguishing on equipment that is under voltage is always hazardous. Conventional fire fighting equipment applicable to this task includes powder and gas extinguishers, which, however, have some drawbacks. Therefore, attention has been increasingly devoted to high-pressure fire extinguishing, whose assets include better heat removal as compared to a full water flow where the majority of the water runs off without any cooling effect. This article describes the testing of some types and combinations of extinguishing techniques and their interpretation based on earth-leakage current measurement and determination of a safe distance for fire extinguishing. Methodology described in CSN IEC 60-1:1994 and CSN EN 3-7:2004 was applied. To meet the criterion, none of the tests was to exhibit an earth-leakage current higher than 0.5 mA. In the accredited laboratory test room setup, 3 extinguishing equipment arrangements proved to extinguish fire on electrical equipment under voltage at a safe distance of 1 m (or 3 m). (orig.)

  4. Halon Flightline Extinguisher Evaluation: Data Supporting Standard Development

    National Research Council Canada - National Science Library

    Dierdorf, Dougls S; Kiel, Jennifer C

    2005-01-01

    .... An F-100 engine nacelle mockup was used to evaluate the full extinguishment times and amount of extinguishing agent used on a series of twenty aft engine and pool fires of 100-ft2 and ten access panel fires...

  5. Extinguishing agent for combustible metal fires

    Science.gov (United States)

    Riley, John F.; Stauffer, Edgar Eugene

    1976-10-12

    A low chloride extinguishing agent for combustible metal fires comprising from substantially 75 to substantially 94 weight percent of sodium carbonate as the basic fire extinguishing material, from substantially 1 to substantially 5 weight percent of a water-repellent agent such as a metal stearate, from substantially 2 to substantially 10 weight percent of a flow promoting agent such as attapulgus clay, and from substantially 3 to substantially 15 weight percent of a polyamide resin as a crusting agent.

  6. Research on fire extinguishing and disaster measures techniques for nuclear facilities

    International Nuclear Information System (INIS)

    Tsuruda, Takashi; Amano, Hisanori; Liao, Chihong

    2004-01-01

    As for a fire of alkali metals in nuclear facilities, measures to cope with the situation should be prepared. It has been experimentally investigated with a success to stabilize and treat safe in the air the leavings of burned sodium, which were extinguished by the nitrogen and poured with fire extinguishing powder for metal fire. Furthermore research and development has been conducted on a series of robots such as installing protection wall between radiation sources and victims and carrying victims out of the disaster room. Basic functional experiments on key components of robot system have been carried out using a trial product. Total control system of a series of robots will be updated based on control mechanism and software of a trial robot system. (T. Tanaka)

  7. 30 CFR 57.4203 - Extinguisher recharging or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Extinguisher recharging or replacement. 57.4203 Section 57.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Prevention and Control Firefighting Equipment § 57.4203 Extinguisher recharging or replacement. Fire...

  8. 30 CFR 56.4203 - Extinguisher recharging or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Extinguisher recharging or replacement. 56.4203 Section 56.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Prevention and Control Firefighting Equipment § 56.4203 Extinguisher recharging or replacement. Fire...

  9. AT89S52 microcontroller Based A Fire Extinguisher Robot Using Ultrasonic and Ultraviolet Sensor

    Directory of Open Access Journals (Sweden)

    Wahyu Sapto Aji

    2009-12-01

    Full Text Available The fire often takes many victims. Fire detection system sometime can not prevent this from happening. Therefore, it is essential to develop a robot that can detect the present of fire as well as extinguish it. This research aimed to design a fire extinguisher robot using AT89S52 microcontroller as its controller. A DC fan controlled by a relay is utilized to put out the fire and a fire sensor (UV-Tron is used to detect the presence of fire. The movement of the robot is driven by motor DC. The robot can detect the surrounding obstacles and possess an ultrasound-based navigation system. If the ultrasound system detects an obstacle, the robot will automatically turn without colliding the obstacle or other things around it. The result has shown that this fire extinguisher robot can be built using hardware and software controlled by an AT89S52 microcontroller. It can be concluded from the tests that the robot can detect fire as far as 5 meter distance and able to successfully put out the fire.

  10. 33 CFR 149.409 - How many fire extinguishers are needed?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many fire extinguishers are needed? 149.409 Section 149.409 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Fire Protection Equipment Firefighting Requirements § 149.409 How many fire extinguishers are needed...

  11. Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-19

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  12. Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-08

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  13. Novel approach for extinguishing large-scale coal fires using gas-liquid foams in open pit mines.

    Science.gov (United States)

    Lu, Xinxiao; Wang, Deming; Qin, Botao; Tian, Fuchao; Shi, Guangyi; Dong, Shuaijun

    2015-12-01

    Coal fires are a serious threat to the workers' security and safe production in open pit mines. The coal fire source is hidden and innumerable, and the large-area cavity is prevalent in the coal seam after the coal burned, causing the conventional extinguishment technology difficult to work. Foams are considered as an efficient means of fire extinguishment in these large-scale workplaces. A noble foam preparation method is introduced, and an original design of cavitation jet device is proposed to add foaming agent stably. The jet cavitation occurs when the water flow rate and pressure ratio reach specified values. Through self-building foaming system, the high performance foams are produced and then infused into the blast drilling holes at a large flow. Without complicated operation, this system is found to be very suitable for extinguishing large-scale coal fires. Field application shows that foam generation adopting the proposed key technology makes a good fire extinguishment effect. The temperature reduction using foams is 6-7 times higher than water, and CO concentration is reduced from 9.43 to 0.092‰ in the drilling hole. The coal fires are controlled successfully in open pit mines, ensuring the normal production as well as the security of personnel and equipment.

  14. Synthesis of Fire-Extinguishing Dawsonites

    Science.gov (United States)

    Altman, R. L.

    1982-01-01

    Simple nonaqueous process synthesizes sodium or potassium, dawsonites effective against hydrocarbon fuel fires. Fire-extinguishing alkali metal dawsonites are prepared using a finely-pulverized equimolar mixture of hydrogen carbonate, or carbonates and aluminum hydroxide heated for 1 to 6 hours under carbon dioxide pressure.

  15. Reinstatement of an Extinguished Fear Conditioned Response in Infant Rats

    Science.gov (United States)

    Revillo, Damian A.; Trebucq, Gastón; Paglini, Maria G.; Arias, Carlos

    2016-01-01

    Although it is currently accepted that the extinction effect reflects new context-dependent learning, this is not so clear during infancy, because some studies did not find recovery of the extinguished conditioned response (CR) in rodents during this ontogenetic stage. However, recent studies have shown the return of an extinguished CR in infant…

  16. Techniques for extinguishing sodium fires

    International Nuclear Information System (INIS)

    Raju, Chander; Kale, R.D.

    1979-02-01

    The experimental work done to evaluate the performance of commercially available fire extinguishants and powders for sodium fires is described. Dry chemical powder with sodium bicarbonate base was found very effective. Another effective method of extinghishing fire by using perforated covered tray is also discussed. (auth.)

  17. 30 CFR 77.1111 - Welding, cutting, soldering; use of fire extinguisher.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding, cutting, soldering; use of fire... OF UNDERGROUND COAL MINES Fire Protection § 77.1111 Welding, cutting, soldering; use of fire extinguisher. One portable fire extinguisher shall be provided at each location where welding, cutting, or...

  18. Analysis of Flame Extinguishment and Height in Low Frequency Acoustically Excited Methane Jet Diffusion Flame

    Science.gov (United States)

    Zong, Ruowen; Kang, Ruxue; Liu, Chen; Zhang, Zhiyang; Zhi, Youran

    2018-01-01

    The exploration of microgravity conditions in space is increasing and existing fire extinguishing technology is often inadequate for fire safety in this special environment. As a result, improving the efficiency of portable extinguishers is of growing importance. In this work, a visual study of the effects on methane jet diffusion flames by low frequency sound waves is conducted to assess the extinguishing ability of sound waves. With a small-scale sound wave extinguishing bench, the extinguishing ability of certain frequencies of sound waves are identified, and the response of the flame height is observed and analyzed. Results show that the flame structure changes with disturbance due to low frequency sound waves of 60-100 Hz, and quenches at effective frequencies in the range of 60-90 Hz. In this range, 60 Hz is considered to be the quick extinguishing frequency, while 70-90 Hz is the stable extinguishing frequency range. For a fixed frequency, the flame height decreases with sound pressure level (SPL). The flame height exhibits the greatest sensitivity to the 60 Hz acoustic waves, and the least to the 100 Hz acoustic waves. The flame height decreases almost identically with disturbance by 70-90 Hz acoustic waves.

  19. Nitrogen gas extinguisher system as a countermeasure against a sodium fire at Monju

    International Nuclear Information System (INIS)

    Hasegawa, M.; Ikeda, M.; Kikuchi, H.

    2001-01-01

    Monju is a prototype sodium cooled FBR in Japan and occurred a sodium leakage incident in the secondary heat transport system on Dec. 8, 1995. The cause of the sodium leakage was a thermocouple well tube failure resulting from high cycle fatigue due to flow-induced vibration. The investigative research revealed that this type of flow-induced vibration was not a well-known Von Karman vortex shedding, but a symmetric vortex shedding. In the light of lessons from the sodium leakage incident, Monju will take several improvements in order to enhance the safety and reliability of the plant. A nitrogen gas extinguisher system will be installed at Monju as one of countermeasures against sodium fires. The basic design specifications of the system were determined by some experiments. Three kinds of experiment were conducted with the object of confirming; (1) an oxygen concentration to suppress the sodium fire, (2) a nitrogen gas mixing efficiency to decrease the oxygen concentration, and (3) a nitrogen gas feed rate to prevent air in-leak from the outside to keep the low oxygen atmosphere. This paper reports these tests which were performed to determine the design specification of the system. (authors)

  20. Nitrogen gas extinguisher system as a countermeasure against a sodium fire at Monju

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, M; Ikeda, M [MONJU Construction Office, Japan Nuclear Cycle Development Institute (Japan); Kikuchi, H [Kobe Shipyard, Mitsubishi Heavy Industries, Ltd, Kobe (Japan)

    2001-07-01

    Monju is a prototype sodium cooled FBR in Japan and occurred a sodium leakage incident in the secondary heat transport system on Dec. 8, 1995. The cause of the sodium leakage was a thermocouple well tube failure resulting from high cycle fatigue due to flow-induced vibration. The investigative research revealed that this type of flow-induced vibration was not a well-known Von Karman vortex shedding, but a symmetric vortex shedding. In the light of lessons from the sodium leakage incident, Monju will take several improvements in order to enhance the safety and reliability of the plant. A nitrogen gas extinguisher system will be installed at Monju as one of countermeasures against sodium fires. The basic design specifications of the system were determined by some experiments. Three kinds of experiment were conducted with the object of confirming; (1) an oxygen concentration to suppress the sodium fire, (2) a nitrogen gas mixing efficiency to decrease the oxygen concentration, and (3) a nitrogen gas feed rate to prevent air in-leak from the outside to keep the low oxygen atmosphere. This paper reports these tests which were performed to determine the design specification of the system. (authors)

  1. Neural circuits involved in the renewal of extinguished fear.

    Science.gov (United States)

    Chen, Weihai; Wang, Yan; Wang, Xiaqing; Li, Hong

    2017-07-01

    The last 10 years have witnessed a substantial progress in understanding the neural mechanisms for the renewal of the extinguished fear memory. Based on the theory of fear extinction, exposure therapy has been developed as a typical cognitive behavioral therapy for posttraumatic stress disorder. Although the fear memory can be extinguished by repeated presentation of conditioned stimulus without unconditioned stimulus, the fear memory is not erased and tends to relapse outside of extinction context, which is referred to as renewal. Therefore, the renewal is regarded as a great obstruction interfering with the effect of exposure therapy. In recent years, there has been a great deal of studies in understanding the neurobiological underpinnings of fear renewal. These offer a foundation upon which novel therapeutic interventions for the renewal may be built. This review focuses on behavioral, anatomical and electrophysiological studies that interpret roles of the hippocampus, prelimbic cortex and amygdala as well as the connections between them for the renewal of the extinguished fear. Additionally, this review suggests the possible pathways for the renewal: (1) the prelimbic cortex may integrate contextual information from hippocampal inputs and project to the basolateral amygdala to mediate the renewal of extinguished fear memory; the ventral hippocampus may innervate the activities of the basolateral amygdala or the central amygdala directly for the renewal. © 2017 IUBMB Life, 69(7):470-478, 2017. © 2017 International Union of Biochemistry and Molecular Biology.

  2. Research on environmental impact of water-based fire extinguishing agents

    Science.gov (United States)

    Wang, Shuai

    2018-02-01

    This paper offers current status of application of water-based fire extinguishing agents, the environmental and research considerations of the need for the study of toxicity research. This paper also offers systematic review of test methods of toxicity and environmental impact of water-based fire extinguishing agents currently available, illustrate the main requirements and relevant test methods, and offer some research findings for future research considerations. The paper also offers limitations of current study.

  3. Extinguishing smouldering fires in silos. BRANDFORSK project 745-961

    Energy Technology Data Exchange (ETDEWEB)

    Tuomisaari, M.; Baroudi, D.; Latva, R. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1998-11-01

    Combustible, porous materials may self-ignite during their storage time in silos as a result of internal heating. The self-ignition process may be slow, and it results in smouldering fires that are extremely difficult to extinguish. Suitable means to fight the smouldering fire were studied both theoretically and experimentally. General heat and mass transfer equations for porous media subject to fires and suppression were written. The equations together with dimensional analysis revealed critical parameters, like the grain size and moisture content, affecting the combustion and suppression process, but they also revealed the complexity of the problem. Experimental results of over 50 tests with varying combustibles and suppression agents were used as the basis for proposed qualitative guidelines on how to fight a smouldering silo fire. Among the potential gaseous agents, CO{sub 2} was found to be the most efficient one. Low expansion foam was also found to be a potential candidate, but its applicability requires further confirmation. Quantifying the guidelines requires a whole new study on the detection of a smouldering fire. The same detection system should be capable of monitoring the suppression process and - most importantly - verifying the extinguishment. (orig.) 46 refs.

  4. Sodium fires and its extinguishment

    International Nuclear Information System (INIS)

    Mikhedov, V.G.

    1979-01-01

    The fire safety problems of NPP with sodium coolants in USSR are presented. The design of sodium reactors is made with premises with sodium coolants being hermetic and filled with nitrogen. Some engineering solutions of fire safety including design, elaboration and choice of construction and protection materials are presented. Some theoretical aspects of sodium burning are presented as well as methods of sodium fire extinguishing methods including the use of powder

  5. The Effect of Extinguishing Agents on Burning Sonobuoys Containing Lithium-Sulfur Dioxide Batteries

    Science.gov (United States)

    1989-09-01

    components and the JP-5. In addition, the types of extinguish- ment materials, such as carbor spheres, that have some degree of success on metal fires , would...NWC TP 6571, publication UNCLASSIFIED.) 8. John F. Riley. "Na-X, a New Fire Extinguishing Agent for Metal Fires ," Fire Technology, Vol. 10, No. 4

  6. The development and evaluation of water-mist fire extinguishing systems

    Science.gov (United States)

    Beason, D. G.; Staggs, K. J.

    1994-08-01

    Fire protection for underfloor space is primarily provided by Halon 1301 which has proven to be very effective. However, due to the link between halons and the possible depletion of the stratospheric ozone layer, plans have been implemented to eventually phase out Halon 1301 and 1211. In September 1987 the Montreal Protocol concerning chlorofluorocarbons (CFC) and halons was signed by the United States, the European Economic Community, and 23 other nations. The Montreal Protocol calls for freezing halon production at 1986 levels. Because the majority of underfloor fire protection at Lawrence Livermore National Laboratory (LLNL), as well as other Department of Energy (DOE) sites, is either Halon 1301 or sprinklers, some other means of suppression will have to be developed and verified. The potential loss to facilities housing computer or control rooms damaged by underfloor fires can be extreme. These losses would not only include hardware and software replacement costs, but also lost computing and control capability. Here at LLNL technical research in a facility could be severely affected. Recent studies conducted by the Fire Research Discipline of the Special Projects Division have shown that severe fires fueled by cable insulation can develop within as little as a 6-in-high underfloor space (even with mechanical ventilation shut off). Studies also show that conventional sprinklers may not be effective in preventing this destruction. Therefore, we are investigating the water-mist fire extinguishing system as an alternative to Halon 1301 and sprinklers.

  7. Ignition and combustion of sodium, fire consequences, extinguishment and prevention

    International Nuclear Information System (INIS)

    Malet, J.C.

    1996-01-01

    This document presents the results of work carried out at the IPSN on: sodium inflammation, sodium combustion (pool fires and sprayed jet fires), extinguishment (passive means and extinguishing powder), the physico-chemical behaviour of aerosols and their filtration, the protection means of concretes, intervention during and after a fire, treatment of residues, intervention equipment. The calculation codes developed during these studies are described. The experimental basis which allowed the qualification of these codes and the technological means aimed at prevention and sodium fire fighting, was obtained using programmes carried out in the experimental facilities existing in Cadarache or in collaboration with the German teams of Karlsruhe

  8. Ignition and combustion of sodium, fire consequences, extinguishment and prevention

    Energy Technology Data Exchange (ETDEWEB)

    Malet, J C [Institut de Protection et de Surete Nucleaire, Laboratoire d' Experimentation de Modelisation des Feux, C.E. Cadarache, Saint-Paul-lez-Durance (France). E-mail: malet at ipsncad.cea.fr

    1996-07-01

    This document presents the results of work carried out at the IPSN on: sodium inflammation, sodium combustion (pool fires and sprayed jet fires), extinguishment (passive means and extinguishing powder), the physico-chemical behaviour of aerosols and their filtration, the protection means of concretes, intervention during and after a fire, treatment of residues, intervention equipment. The calculation codes developed during these studies are described. The experimental basis which allowed the qualification of these codes and the technological means aimed at prevention and sodium fire fighting, was obtained using programmes carried out in the experimental facilities existing in Cadarache or in collaboration with the German teams of Karlsruhe.

  9. 16 CFR 1500.15 - Labeling of fire extinguishers.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Labeling of fire extinguishers. 1500.15 Section 1500.15 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT...)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when used to...

  10. 78 FR 70324 - Thy Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2013-11-25

    ... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of...) approval of the information collection requirements contained in the Hydrostatic Testing provision of the... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard are necessary to reduce workers...

  11. Spontaneous Recovery But Not Reinstatement of the Extinguished Conditioned Eyeblink Response in the Rat

    Science.gov (United States)

    Thanellou, Alexandra; Green, John T.

    2011-01-01

    Reinstatement, the return of an extinguished conditioned response (CR) after reexposure to the unconditioned stimulus (US), and spontaneous recovery, the return of an extinguished CR with the passage of time, are two of four well-established phenomena which demonstrate that extinction does not erase the conditioned stimulus (CS)-US association. However, reinstatement of extinguished eyeblink CRs has never been demonstrated and spontaneous recovery of extinguished eyeblink CRs has not been systematically demonstrated in rodent eyeblink conditioning. In Experiment 1, US reexposure was administered 24 hours prior to a reinstatement test. In Experiment 2, US reexposure was administered 5 min prior to a reinstatement test. In Experiment 3, a long, discrete cue (a houselight), present in all phases of training and testing, served as a context within which each trial occurred to maximize context processing, which in other preparations has been shown to be required for reinstatement. In Experiment 4, an additional group was included that received footshock exposure, rather than US reexposure, between extinction and test, and contextual freezing was measured prior to test. Spontaneous recovery was robust in Experiments 3 and 4. In Experiment 4, context freezing was strong in a group given footshock exposure but not in a group given eyeshock US reexposure. There was no reinstatement observed in any experiment. With stimulus conditions that produce eyeblink conditioning and research designs that produce reinstatement in other forms of classical conditioning, we observed spontaneous recovery but not reinstatement of extinguished eyeblink CRs. This suggests that reinstatement, but not spontaneous recovery, is a preparation- or substrate-dependent phenomenon. PMID:21517145

  12. Refractometry and Extinguishment/Burnback Testing of Pacific Air Forces AFFF

    National Research Council Canada - National Science Library

    Kalberer, Jennifer L; Barrett, Kimberly D

    2006-01-01

    At the request of Pacific Air Forces (PACAF), the Air Force Research Laboratory (AFRL) performed refractometry and extinguishment/burnback tests on samples of Ansulite and 3M aqueous film forming foam...

  13. 75 FR 20516 - Special Conditions: Cirrus Design Corporation, Model SF50; Fire Extinguishing for Upper Aft...

    Science.gov (United States)

    2010-04-20

    ... defined in Sec. 11.19, under Sec. 11.38 and they become part of the type certification basis under Sec. 21... requiring and defining engine compartment fire extinguishing systems already exist for part 23 commuter... structure or the fuselage. In essence the engine could burn off of the pylon and not adversely compromise...

  14. Fire extinguishment in hypobaric and hyperbaric environments

    Science.gov (United States)

    Kimzey, J. H.

    1971-01-01

    Work that has been performed to provide information on the effects of various fire extinguishing agents in special atmospheres is discussed. Data used in the development of both equipment and techniques for manned spacecraft and related equipment are discussed. The equipment includes a hypobaric chamber suitable for low pressure use and a hyperbaric chamber for high pressure operation. The effectiveness of agents in weightless environment is also discussed.

  15. Testing of a graphite based extinguishing powder for use on liquid metal fires

    International Nuclear Information System (INIS)

    Menzenhauer, P.; Ochs, G.; Peppler, W.

    1977-11-01

    A graphite based extinguishing powder, newly developed by a French firm for use on liquid metal fires has been tested on a sodium fire in a pan of 0.96 m 2 using 60 kg of sodium. The behaviour and extinguishing power are reported and compared with those of other materials tested in earlier experiments. The new powder has excellent efficiency in dealing with sodium pool fires. Application is simple. The amount required is more than an order magnitude less than that of currently available alternatives. The powder is not corrosive. (orig.) [de

  16. Use of Video Modeling to Teach Extinguishing of Cooking Related Fires to Individuals with Moderate Intellectual Disabilities

    Science.gov (United States)

    Mechling, Linda C.; Gast, David L.; Gustafson, Melissa R.

    2009-01-01

    This study evaluated the effectiveness of video modeling to teach fire extinguishing behaviors to three young adults with moderate intellectual disabilities. A multiple probe design across three fire extinguishing behaviors and replicated across three students was used to evaluate the effectiveness of the video-based program. Results indicate that…

  17. Analysis of patents on extinguishing agent for sodium fires

    International Nuclear Information System (INIS)

    Jeong, Ji Young; Jeong, K. C.; Kim, B. H.; Kim, T. J.; Choi, J. H.

    2002-02-01

    This report relates to the extinction of sodium fires, particularly where the burning sodium is in liquid form. The total of 14 patents on extinguishing agents for sodium fires patented from 1969 to 1997 are analyzed and summarized. All of the patents analyzed were issued from USA, France and Japan

  18. Analysis of patents on extinguishing agent for sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Jeong, K C; Kim, B H; Kim, T J; Choi, J H

    2002-02-01

    This report relates to the extinction of sodium fires, particularly where the burning sodium is in liquid form. The total of 14 patents on extinguishing agents for sodium fires patented from 1969 to 1997 are analyzed and summarized. All of the patents analyzed were issued from USA, France and Japan.

  19. 46 CFR 76.50-10 - Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Location. 76.50-10 Section 76.50-10 Shipping COAST GUARD... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  20. Solid State MEMS Thrusters Using Electrically Controlled Extinguishable Solid Propellant, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ET Materials, LLC developed the first ever electrically controlled extinguishable solid propellant (ECESP). The original propellant developed under Air Force SBIR...

  1. Relapse of Extinguished Fear after Exposure to a Dangerous Context Is Mitigated by Testing in a Safe Context

    Science.gov (United States)

    Goode, Travis D.; Kim, Janice J.; Maren, Stephen

    2015-01-01

    Aversive events can trigger relapse of extinguished fear memories, presenting a major challenge to the long-term efficacy of therapeutic interventions. Here, we examined factors regulating the relapse of extinguished fear after exposure of rats to a dangerous context. Rats received unsignaled shock in a distinct context ("dangerous"…

  2. Numerical prediction of fire extinguishment characteristics of sodium leak collection tray in a fast breeder reactor

    International Nuclear Information System (INIS)

    Diwakar, S.V.; Mangarjuna Rao, P.; Kasinathan, N.; Das, Sarit K.; Sundararajan, T.

    2011-01-01

    Highlights: ► Sodium fire extinguishment in a leak collection tray is modeled by lumped approach. ► Hydrodynamics of liquid sodium on tray is emulated through a draining/sloshing model. ► Pool burning rates in the tray and holdup vessel are numerically estimated. ► The model directly yields the mass of sodium recovered after extinction of fire. ► Model predictions are in reasonable agreement with the available experimental data. - Abstract: Sodium leak collection tray (LCT) is an efficient passive device used for the extinguishment of liquid sodium fire in case of an accidental leakage from the secondary circuit of a fast breeder reactor. The LCT essentially isolates the leaking sodium into closed containers where the resulting fire is extinguished due to limited availability of oxygen. The current work aims to highlight the combustion extinguishment characteristics of LCT through a lumped formulation by conserving the mass and energy of liquid sodium and constituent gases in various parts of the LCT. Here, the complex hydrodynamics of liquid sodium is emulated through a semi-analytical draining/sloshing model and its burning rates are predicted through a three-dimensional open pool combustion model for the tray region and a closed pool combustion model for the holdup vessel. These simulations evaluate the burning rates at discrete levels of liquid sodium which are subsequently interpolated to establish correlations involving instantaneous liquid levels and oxygen concentration. Using the correlations obtained from the draining and combustion models, the overall lumped formulation directly predicts the un-burnt sodium recoverable after the extinguishment of fire in the LCT. The predicted results of this model compare well with the available experimental data.

  3. Fighting fire with gas. CO{sub 2} extinguishes smouldering fires in biomass silos and waste bunkers; Effizientes Feuerwehr-Gas. CO{sub 2} loescht Schwelbraende in Biomasse-Silos und Abfallbunkern

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-07-01

    Organic materials are a great source of energy and so biomass is in big demand. But wherever large amounts of wood, waste and straw are stored in huge silos, there is also a risk of smouldering fires and even explosions. Conventional methods are relatively ineffective at extinguishing fires such as these. But a new extinguishing system from Linde uses CO{sub 2} to effectively fight smouldering fires at the source. (orig.)

  4. Fire extinguishing strength of the combustion product of wood saw ...

    African Journals Online (AJOL)

    Forty saw dust samples from four mature hard wood plants grown in southwestern part of Nigeria were analyzed for their ash contents, moisture contents, metallic contents and hence the fire extinguishing strength of the saw dust ash by classical and instrumental methods of analyses. Mahogany (Khaya ivorensis) wood saw ...

  5. 46 CFR 27.305 - What are the requirements for fire-extinguishing equipment on towing vessels in ocean or coastal...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false What are the requirements for fire-extinguishing equipment on towing vessels in ocean or coastal service whose construction was contracted for on or after... for fire-extinguishing equipment on towing vessels in ocean or coastal service whose construction was...

  6. Counterconditioned Fear Responses Exhibit Greater Renewal than Extinguished Fear Responses

    Science.gov (United States)

    Holmes, Nathan M.; Leung, Hiu T.; Westbrook, R. Frederick

    2016-01-01

    This series of experiments used rats to compare counterconditioning and extinction of conditioned fear responses (freezing) with respect to the effects of a context shift. In each experiment, a stimulus was paired with shock in context A, extinguished or counterconditioned through pairings with sucrose in context B, and then tested for renewal…

  7. Using egg albumin foam to extinguish fires

    Directory of Open Access Journals (Sweden)

    Hytham A. Alsaati

    2003-12-01

    Full Text Available Oil, coal and chemical fires are often difficult to put out using water. In certain hydrocarbon fires, protein foam can extinguish fires better than water by keeping air (oxygen away from the flames and by ''blowing'' the flame away from its fuel source. Egg albumin is a relatively inexpensive protein and is representative of foaming proteins, which are candidates for use as fire suppression agents. This paper begins to deal with the effect of the foam bulk pH, foam protein concentration and generating air flow rate into the foam on the fire extinguishing time in laboratory experiments. A Bunsen burner was used to generate a small, controlled laboratory fire within a plastic container, which represented a point source in a partially open room in the experiments. The Bunsen burner represents a gaseous hydrocarbon fire, which can be difficult to extinguish. Both a low pH foam and one made with a high air flow rate favor a reduction in time required to put out the Bunsen burner flame.Chamas produzidas por óleo, carvão e produtos químicos (incêndios provocados são difíceis de ser extinguidos com água. Algumas chamas de hidrocarbonetos podem ser extinguidas por espumas protéicas melhor do que a manutenção de ar (oxigênio fora do alcance das chamas ou pelo sopramento da chama para longe da sua fonte. Albumina de ovo é uma proteína relativamente barata e é representativa dentre as proteínas usadas como espuma para a (supressão extinção de agentes causadores de incêndio. Este artigo trata do estudo do efeito do pH e concentração da espuma protéica, além da geração de ar no interior da espuma, sobre o tempo de extinção de incêndio em experimentos laboratoriais. Nos experimentos um bico de Bunsen foi usado para gerar uma pequena chama, controlada em um container de plástico, representando uma fonte pontual em um ambiente parcialmente aberto. A chama do bico de Bunsen representa uma chama gasosa de hidrocarbonetos, que são dif

  8. Experimental study of hydrogen jet ignition and jet extinguishment

    International Nuclear Information System (INIS)

    Wierman, R.W.

    1979-04-01

    Two phases are described of an experimental study that investigated: (1) the ignition characteristics of hydrogen--sodium jets, (2) the formation of hydrogen in sodium--humid air atmospheres, and (3) the extinguishment characteristics of burning hydrogen--sodium jets. Test conditions were similar to those postulated for highly-improbable breeder reactor core melt-through accidents and included: jet temperature, jet velocity, jet hydrogen concentration, jet sodium concentration, atmospheric oxygen concentration, and atmospheric water vapor concentration

  9. 46 CFR 95.50-5 - Classification.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Classification. 95.50-5 Section 95.50-5 Shipping COAST... Details § 95.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire extinguishing... extinguishing systems are set forth in Table 95.50-5(c). Table 95.50-5(c) Classification Type Size Soda-acid and...

  10. 安全评价中作业场所灭火器配置评价的研究%Research on safety assessment of extinguisher distribution in workplace

    Institute of Scientific and Technical Information of China (English)

    董国强; 胡凌艳; 张双保; 张颖; 杨勇

    2011-01-01

    灭火器具有轻便灵活,易于掌握操作的特点,是扑救初起火灾的重要消防器材,对应急状态下的消防火火工作尤为重要.在建设项目安全预评价和验收评价中,往往受项目建设内容多,可行性研究报告或初步设计中对消防灭火器配置的设计详细程度有限等因素的影响,评价人员对建设项目作业场所灭火器配置情况是否符合相关规范、标准的要求,更多是通过检查该建设项目是否通过了当地公安消防部门的消防设计审核或消防验收来予以确认,往往很难具体确定作业场所灭火器材的配置包括规格、数量、设置位置是否满足该作业场所的要求.鉴于作业场所灭火器设置的重要性,就如何在建设项目安全评价中更好的对作业场所灭火器材的配备与设计进行评价,本文通过实例进行分析说明.旨在保证项目设计过程中对灭火器材配备的准确性,避免因灭火器配置规格、数量、位置的不当,造成火灾事故现场后果的严重化、扩大化,以减少火灾损失,保障人身和财产安全.%Fire extinguisher is a very important fire control device. It is flexible handing and can be easily operated by operation staffs who have been simply trained. So it is very important for fire fighting in emergency condition. In construction project safety assessment prior to start and construction project safety assessment upon completion,safety assessment staffs usually evaluate the extinguisher distribution situation whether meets the code and standard requirements according to check the construction project whether passes the fire control design examination or acceptance approval. It is usually difficult for them to concretely confirm whether extinguisher distribution including model、amount and setting position is meeting the workplace request. Because the design of extinguisher distribution is not detailed enough in feasibility study report and primary layout

  11. DEVELOPMENT OF A WATER SPOUT FOR THE ACTIVE EXTINGUISHING OF THE FOCUS OF AN INTENSE FLAME

    Directory of Open Access Journals (Sweden)

    Stanislav LICHOROBIEC

    2017-12-01

    Full Text Available The topic of the article is devoted to the experimental development of directional charges, which have a front part filled with water and are thus capable of forming a high velocity water jet, which has intense cooling effects and is accompanied by a shock wave created by the explosion of the charge. The water jet can then be used to extinguish the flame from an intense fire epicenter caused, for example, by a gas pipe failure, a tank with flammable liquid or an oil well. The text is accompanied with the visual design of the water spout prototype, including the experimental test of extinguishing the focus of an intense flame caused by various sources.

  12. Development of a Standard Test Scenario to Evaluate the Effectiveness of Portable Fire Extinguishers on Lithium-ion Battery Fires

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susan A.; Hirsch, David B.; Carriere, Thierry

    2013-01-01

    Many sources of fuel are present aboard current spacecraft, with one especially hazardous source of stored energy: lithium ion batteries. Lithium ion batteries are a very hazardous form of fuel due to their self-sustaining combustion once ignited, for example, by an external heat source. Batteries can become extremely energetic fire sources due to their high density electrochemical energy content that may, under duress, be violently converted to thermal energy and fire in the form of a thermal runaway. Currently, lithium ion batteries are the preferred types of batteries aboard international spacecraft and therefore are routinely installed, collectively forming a potentially devastating fire threat to a spacecraft and its crew. Currently NASA is developing a fine water mist portable fire extinguisher for future use on international spacecraft. As its development ensues, a need for the standard evaluation of various types of fire extinguishers against this potential threat is required to provide an unbiased means of comparing between fire extinguisher technologies and ranking them based on performance.

  13. 75 FR 48728 - The Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2010-08-11

    ... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of... the information collection requirements contained in the Hydrostatic Testing provision of the Portable... 48729

  14. Sodium fires and its extinguishment; Gorenie, sredstva i sposoby tusheniya natriya

    Energy Technology Data Exchange (ETDEWEB)

    Mikhedov, V G

    1979-03-01

    The fire safety problems of NPP with sodium coolants in USSR are presented. The design of sodium reactors is made with premises with sodium coolants being hermetic and filled with nitrogen. Some engineering solutions of fire safety including design, elaboration and choice of construction and protection materials are presented. Some theoretical aspects of sodium burning are presented as well as methods of sodium fire extinguishing methods including the use of powder.

  15. Assessment of Application Example for a Sodium Fire Extinguishing Facility using Safety Control of Dangerous Substances Act

    International Nuclear Information System (INIS)

    Jung, Minhwan; Jeong, Ji-Young; Kim, Jongman

    2014-01-01

    Sodium is under regulation of four kinds of laws including the Safety Control of Dangerous Substances Act and it is under categorized as Class 3(pyrophoric material, water-prohibiting substance). To obtain a license for a sodium experiment facility, the codes and regulations must be satisfied in the Safety Control of Dangerous Substance Act. However, there are some parts that need to be discussed in related regulations in the Safety Control of Dangerous Substance Act because there are differences with the actual features of sodium. To apply for an actual sodium facility, it is necessary to give a supplementary explanation regarding the regulations. The objective of this study is to assess the application example of a sodium experiment facility using the above mentioned laws and to propose the necessity of an amendment for conventional laws in regard to fire extinguishing systems and agents. In this work, an application example of a sodium experiment facility using the Safety Control of Dangerous Substances Act, and the necessity of amending the existing laws in regard to fire extinguishing systems including the agent used, was assessed. The safest standard was applied for cases in which the consideration of a sodium fire is not mentioned in conventional regulations. For the construction of the PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor), the described regulations in this work should be reviewed and improved carefully by the fire safety regulatory body

  16. Dynamics of plasma catecholamine and corticosterone concentrations during reinforced and extinguished operant behavior in rats

    NARCIS (Netherlands)

    de Boer, S.F.; de Beun, R; Slangen, J L; van der Gugten, J

    Plasma noradrenaline (NA), adrenaline (A) and corticosterone (CS) concentrations were determined simultaneously in permanently heart-cannulated rats before and during the performance of reinforced and nonreinforced (extinguished) operant behavior. Shortly before the experimental food-reinforced (VI

  17. Possibility of increasing the fire-suppression efficiency of the foam in automatic extinguishing installations

    Science.gov (United States)

    Kachanov, I. V.; Veremenyuk, V. V.; Karpenchuk, I. V.; Pavlyukov, S. Yu.

    2013-05-01

    The mechanics of movement of a liquid in the diffuser of the injector of an automatic extinguishing installation with preaeration of the fire-fighting substance was theoretically investigated. An integral solution of the equation for movement of the preaerated fire-fighting gas-liquid mixture in the indicated diffuser has been obtained. A mathematical model of two-phase liquid flow in this diffuser, which allows one to calculate the distribution of the average pressure in the diffuser along its length and to determine the loss in this pressure, has been developed. This model can be used for designing the output region of a hydraulic system with a hydrodynamic drag providing the operation of its injector in a definite regime.

  18. Method for Increasing the Efficiency of Automatic Fire Extinguish System at Objects Of Power

    Directory of Open Access Journals (Sweden)

    Dmitrienko Margarita

    2015-01-01

    Full Text Available Operation of energy facilities requires compliance with all safety standards, and especially fire safety. Emergency situations that arise when operated the power equipment damage not only the objects of the technosphere but also the environment. In recent years, can be noted a trend of quite intensive development of technological bases of technology water mist fire extinguishing. Using the methods of optical panoramic imaging PIV, IPI and the method of high-speed video recording were performed the experimental studies of the characteristics of evaporation of large single water droplets as they pass through the flames of oil and oil products with varying parameters of the processes (the initial size of 2–6 mm, the rate of 2–4 m/s and the temperature of water drops 290–300 K, the temperature of the combustion products 185–2073 K. Was established decisive influence droplet size, velocities at which droplets enter the gaseous medium, the initial water temperature on heating rate and evaporation of droplets in a stream of high-temperature combustion products.

  19. Investigation of the Extinguishing Features for Liquid Fuels and Organic Flammable Liquids Atomized by a Water Flow

    Directory of Open Access Journals (Sweden)

    Voytkov Ivan V.

    2016-01-01

    Full Text Available The processes of heat and mass transfer were investigated experimentally while moving and evaporating the atomized water flow in high-temperature combustion products of typical liquid fuels and organic flammable liquids: gasoline, kerosene, acetone, crude oil, industrial alcohol. We determined typical periods of liquid extinguishing by an atomized water flow of various dispersability. Data of the discharge of extinguishing medium corresponding to various parameters of atomization and duration of using the atomization devices was presented. It is shown that Um≈3.5 m/s is a minimal outflow velocity of droplets during moving while passing the distance of 1m in the high-temperature gas medium to stop the combustion of organic liquids.

  20. The Effects of Water Spray Cooling in Conjunction with Halogenated Extinguishants on Hydrogen Fluoride Generation and Decay

    National Research Council Canada - National Science Library

    Burch, Ian

    2007-01-01

    The halogenated extinguishants Halon 1301, HFC-227ea (FM200) and NAF-S-III used within Royal Australian Navy vessels for total flooding fire suppression applications have hydrogen fluoride (HF) toxicity concerns...

  1. Experimental study on combustion and suppression characteristics of sodium fire in a columnar flow using extinguishing powder

    International Nuclear Information System (INIS)

    Huo Yan; Zhang Zhigang; Li Jinke; Liu Zhongkun; Ma Yaolong

    2017-01-01

    In the operation of the sodium-cooled fast reactor, the leakage and fire accident of liquid sodium is common and it is frequent in sodium-related facilities. This study focuses on the combustion and suppression characteristics of sodium fire in a columnar flow. Liquid sodium (250°C) is injected into a 7.9 m"3 cylindrical chamber at a flow rate of about 1.0 m"3/h to create a columnar sodium fire, and 18.4 kg class D extinguishing powder is sprayed after the liquid sodium injection. The temperature in the chamber space and sodium collection plate and the heat release rate from sodium fire are measured and analyzed. Based on the temperature data the sodium fire under suppression could be divided into four phases of dropping sharply, continuously remaining lower, rising and declining mildly, and depressing. The sodium fire in the space could be suppressed and cooled down if the extinguishing agent could spray in the early period of the liquid sodium injection. The extinguishing agent could suppress the combustion and spreading of liquid sodium dropping on the collection plate, limit the pool combustion area and postpone the commencement of sodium pool burning in spite of its later re-ignition happening. This study promises to evaluate the combustion and suppression characteristics of sodium fire in the sodium-related facilities. (author)

  2. 46 CFR 193.50-10 - Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Location. 193.50-10 Section 193.50-10 Shipping COAST... Details § 193.50-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in accordance with Table 193.50-10(a). The location of the equipment...

  3. 30 CFR 75.1107-11 - Extinguishing agents; requirements on mining equipment employed in low coal.

    Science.gov (United States)

    2010-07-01

    ... equipment employed in low coal. 75.1107-11 Section 75.1107-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES... § 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal. On mining...

  4. Detailed design report for an operational phase panel-closure system

    International Nuclear Information System (INIS)

    1996-01-01

    Under contract to Westinghouse Electric Corporation (Westinghouse), Waste Isolation Division (WID), IT Corporation has prepared a detailed design of a panel-closure system for the Waste Isolation Pilot Plant (WIPP). Preparation of this detailed design of an operational-phase closure system is required to support a Resource Conservation and Recovery Act (RCRA) Part B permit application and a non-migration variance petition. This report describes the detailed design for a panel-closure system specific to the WIPP site. The recommended panel-closure system will adequately isolate the waste-emplacement panels for at least 35 years. This report provides detailed design and material engineering specifications for the construction, emplacement, and interface-grouting associated with a panel-closure system at the WIPP repository, which would ensure that an effective panel-closure system is in place for at least 35 years. The panel-closure system provides assurance that the limit for the migration of volatile organic compounds (VOC) will be met at the point of compliance, the WIPP site boundary. This assurance is obtained through the inherent flexibility of the panel-closure system

  5. The use of boron trifluoride and alkoxiboroxines as extinguishants for magnesium alloy fires

    International Nuclear Information System (INIS)

    Newman, R.N.

    1987-11-01

    The extinguishants currently available for putting out magnesium alloy fires work by covering the burning fuel and excluding both the oxygen and nitrogen from the reaction zone. It has been reported that boron trifluoride and trimethoxi-and tributoxi-boroxine may act in a more specific chemical way on the combustion reactions. In this report an investigation into the effectiveness of these compounds on magnesium alloy fires is described. (author)

  6. Detailed design of product oriented manufacturing systems

    OpenAIRE

    Silva, Sílvio Carmo; Alves, Anabela Carvalho

    2006-01-01

    This paper presents a procedure for the detailed design and redesign of manufacturing systems within a framework of constantly fitting production system configuration to the varying production needs of products. With such an approach is achieved the design of Product Oriented Manufacturing Systems – POMS. This approach is in opposition to the fitting, before hand, of a production system to all products within a company. In this case is usual to adopt a Function Oriented Manufactur...

  7. Yohimbine reinstates extinguished 3,4-methylenedioxymethamphetamine (MDMA; ecstasy) seeking in rats with prior exposure to chronic yohimbine.

    Science.gov (United States)

    Ball, Kevin T; Jarsocrak, Hanna; Hyacinthe, Johanna; Lambert, Justina; Lockowitz, James; Schrock, Jordan

    2015-11-01

    Although exposure to acute stress has been shown to reinstate extinguished responding for a wide variety of drugs, no studies have investigated stress-induced reinstatement in animals with a history of 3,4-methylenedioxymethamphetamine (MDMA; ecstasy) self-administration. Thus, rats were trained to press a lever for MDMA (0.50 mg/kg/infusion) in daily sessions, and lever pressing was subsequently extinguished in the absence of MDMA and conditioned cues (light and tone). We then tested the ability of acute yohimbine (2.0 mg/kg), a pharmacological stressor, to reinstate lever-pressing under extinction conditions. Additionally, to model chronic stress, some rats were injected daily with yohimbine (5.0 mg/kg × 10 days) prior to reinstatement tests. To assess dopaminergic involvement, chronic yohimbine injections were combined with injections of SCH-23390 (0.0 or 10.0 μg/kg), a dopamine D1-like receptor antagonist. In a separate experiment, rats with a history of food self-administration were treated and tested in the same way. Results showed that acute yohimbine injections reinstated extinguished MDMA and food seeking, but only in rats with a history of chronic yohimbine exposure. Co-administration of SCH-23390 with chronic yohimbine injections prevented the potentiation of subsequent food seeking, but not MDMA seeking. These results suggest that abstinent MDMA users who also are exposed to chronic stress may be at increased risk for future relapse, and also that the effects of chronic stress on relapse may be mediated by different mechanisms depending on one's drug use history. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Suicide by Fire Extinguisher Powder Ingestion: A Case Report

    Directory of Open Access Journals (Sweden)

    Hamid Mohammadi Kojidi

    2017-07-01

    Full Text Available A 51-year-old man committed suicide by swallowing the contents of a fire extinguisher. A few hours after his suicide attempt, he was referred to the medical center for poisoning. At the time of admission, the patient was conscious with stable vital signs. The patient complained of burning lips and mouth, mentioning diarrhea. Initial treatments included gastric lavage with activated charcoal, while paraclinical measures were requested. The patient had undergone hypernatremia (Na: 152 mEq/l and metabolic alkalosis. Treatment focused on the adjustment of sodium level and alkalosis. On the first day of hospitalization, the patient experienced recurrent episodes of tonic-clonic seizure along with the loss of consciousness. On the third day of hospitalization, the patient developed respiratory arrest followed by cardiac arrest and death.

  9. Fire-extinguishing organic electrolytes for safe batteries

    Science.gov (United States)

    Wang, Jianhui; Yamada, Yuki; Sodeyama, Keitaro; Watanabe, Eriko; Takada, Koji; Tateyama, Yoshitaka; Yamada, Atsuo

    2018-01-01

    Severe safety concerns are impeding the large-scale employment of lithium/sodium batteries. Conventional electrolytes are highly flammable and volatile, which may cause catastrophic fires or explosions. Efforts to introduce flame-retardant solvents into the electrolytes have generally resulted in compromised battery performance because those solvents do not suitably passivate carbonaceous anodes. Here we report a salt-concentrated electrolyte design to resolve this dilemma via the spontaneous formation of a robust inorganic passivation film on the anode. We demonstrate that a concentrated electrolyte using a salt and a popular flame-retardant solvent (trimethyl phosphate), without any additives or soft binders, allows stable charge-discharge cycling of both hard-carbon and graphite anodes for more than 1,000 cycles (over one year) with negligible degradation; this performance is comparable or superior to that of conventional flammable carbonate electrolytes. The unusual passivation character of the concentrated electrolyte coupled with its fire-extinguishing property contributes to developing safe and long-lasting batteries, unlocking the limit toward development of much higher energy-density batteries.

  10. Development of a Smart Residential Fire Protection System

    OpenAIRE

    Juhwan Oh; Zhongwei Jiang; Henry Panganiban

    2013-01-01

    Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual...

  11. Potential production of palm oil-based foaming agent as fire extinguisher of peatlands in Indonesia: Literature review

    Science.gov (United States)

    Subekti, P.; Hambali, E.; Suryani, A.; Suryadarma, P.

    2017-05-01

    This study aims to analyze the potential aplication of of palm oil-based foaming agent as peat fires fighter in Indonesia. From literature review, it has been known that the foaming agent able to form foam to extinguish fire, wrap and refrigerate the burning peat. It is necessary to develop the production and application of foaming agent in Indonesia because peat fires occur almost every year that caused smoke haze. Potential raw material for the production of environmental friendly foaming agent as foam extinguishing for peat fires in Indonesia aong other is palm oil due to abundant availability, sustainable, and foam product easily degraded in the environment of the burnt areas. Production of foaming agent as fire-fighting in Indonesia is one alternative to reduce the time to control the fire and smog disaster impact. Application of palm oil as a raw material for fire-fighting is contribute to increase the value added and the development of palm oil downstream industry.

  12. Mathematical Model of Induction Heating Processes in Axial Symmetric Inductor-Detail Systems

    Directory of Open Access Journals (Sweden)

    Maik Streblau

    2014-05-01

    Full Text Available The wide variety of models for analysis of processes in the inductor-detail systems makes it necessary to summarize them. This is a difficult task because of the variety of inductor-detail system configurations. This paper aims to present a multi physics mathematical model for complex analysis of electromagnetic and thermal fields in axial symmetric systems inductor-detail.

  13. Talent in autism: hyper-systemizing, hyper-attention to detail and sensory hypersensitivity.

    Science.gov (United States)

    Baron-Cohen, Simon; Ashwin, Emma; Ashwin, Chris; Tavassoli, Teresa; Chakrabarti, Bhismadev

    2009-05-27

    We argue that hyper-systemizing predisposes individuals to show talent, and review evidence that hyper-systemizing is part of the cognitive style of people with autism spectrum conditions (ASC). We then clarify the hyper-systemizing theory, contrasting it to the weak central coherence (WCC) and executive dysfunction (ED) theories. The ED theory has difficulty explaining the existence of talent in ASC. While both hyper-systemizing and WCC theories postulate excellent attention to detail, by itself excellent attention to detail will not produce talent. By contrast, the hyper-systemizing theory argues that the excellent attention to detail is directed towards detecting 'if p, then q' rules (or [input-operation-output] reasoning). Such law-based pattern recognition systems can produce talent in systemizable domains. Finally, we argue that the excellent attention to detail in ASC is itself a consequence of sensory hypersensitivity. We review an experiment from our laboratory demonstrating sensory hypersensitivity detection thresholds in vision. We conclude that the origins of the association between autism and talent begin at the sensory level, include excellent attention to detail and end with hyper-systemizing.

  14. MIL SPEC 28 Square Foot Fire Burnback and Extinguishment Testing of FireAde, FlameOut II and Hawk ALLFIRE

    National Research Council Canada - National Science Library

    Barrett, Kimberly D; Kalberer, Jennifer L

    2008-01-01

    ... for hydrocarbon fuel fires. This report documents the evaluation performed on the fire extinguishing agents FireAde 2000 AFFF LP, FlameOut II and Hawk ALLFORE in accordance with the parameters set forth in Military Specification ( MIL SPEC...

  15. Flammability of self-extinguishing kenaf/ABS nanoclays composite for aircraft secondary structure

    Science.gov (United States)

    Karunakaran, S.; Majid, D. L.; Mohd Tawil, M. L.

    2016-10-01

    This study investigates the flammability properties of kenaf fiber reinforced acrylonitrile butadiene styrene (ABS) with nanoclays composites. Natural fiber is one of the potential materials to be used with thermoplastic as a composite due to its attractive properties such as lightweight and strong. In this paper, flammability properties of this material are evaluated through Underwriters Laboratory 94 Horizontal Burning (UL94 HB), which has been conducted for both controlled and uncontrolled conditions, smoke density and limiting oxygen index tests (LOI). These flammability tests are in compliance with the Federal Aviation Regulation (FAR) requirement. The results from UL94 HB and smoke density tests show that the presence of nanoclays with effective composition of kenaf fiber reinforced ABS has enhanced the burning characteristics of the material by hindering propagation of flame spread over the surface of the material through char formation. Consequently, this decreases the burning rate and produces low amount of smoke during burning. On contrary, through LOI test, this material requires less oxygen to burn when exposed to fire, which hinders the enhancement of burning characteristics. This is due to burning mechanism exhibited by nanoclays that catalyzes barrier formation and flame propagation rate over the surface of the biocomposite material. Overall, these experimental results suggest that this biocomposite material is capable of self-extinguishing and possesses effective fire extinction. The observed novel synergism from the result obtained is promising to be implemented in secondary structures of aircraft with significant benefits such as cost-effective, lightweight and biodegradable self-extinguishing biocomposite.

  16. Detailed modeling of superconducting magnetic energy storage (SMES) system

    NARCIS (Netherlands)

    Chen, L.; Liu, Y.; Arsoy, A.B.; Ribeiro, P.F.; Steurer, M.; Iravani, M.R.

    2006-01-01

    This paper presents a detailed model for simulation of a Superconducting Magnetic Energy Storage (SMES) system. SMES technology has the potential to bring real power storage characteristic to the utility transmission and distribution systems. The principle of SMES system operation is reviewed in

  17. Extinguishing a learned response in a free-ranging gray wolf (Canis lupus)

    Science.gov (United States)

    Mech, L. David

    2017-01-01

    A free-ranging Gray Wolf (Canis lupus), habituated to human presence (the author) on Ellesmere Island, Canada, learned to anticipate experimental feeding by a human, became impatient, persistent, and bold and exhibited stalking behaviour toward the food source. Only after the author offered the wolf about 90 clumps of dry soil over a period of 45 minutes in three bouts, did the wolf give up this behaviour. To my knowledge, this is the first example of extinguishing a learned response in a free-ranging wolf and provides new insight into the learning behaviour of such animals.

  18. Monitoring system of multiple fire fighting based on computer vision

    Science.gov (United States)

    Li, Jinlong; Wang, Li; Gao, Xiaorong; Wang, Zeyong; Zhao, Quanke

    2010-10-01

    With the high demand of fire control in spacious buildings, computer vision is playing a more and more important role. This paper presents a new monitoring system of multiple fire fighting based on computer vision and color detection. This system can adjust to the fire position and then extinguish the fire by itself. In this paper, the system structure, working principle, fire orientation, hydrant's angle adjusting and system calibration are described in detail; also the design of relevant hardware and software is introduced. At the same time, the principle and process of color detection and image processing are given as well. The system runs well in the test, and it has high reliability, low cost, and easy nodeexpanding, which has a bright prospect of application and popularization.

  19. Development of a Smart Residential Fire Protection System

    Directory of Open Access Journals (Sweden)

    Juhwan Oh

    2013-01-01

    Full Text Available Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual fire test suggests that the developed wireless system for the smart residential fire protection system is reliable in terms of sensors and their communication linkage.

  20. Influence of dispersion degree of water drops on efficiency of extinguishing of flammable liquids

    OpenAIRE

    Korolchenko Dmitriy; Voevoda Sergey

    2016-01-01

    Depending on the size of water drops, process of fire extinguishing is focused either in a zone of combustion or on a burning liquid surface. This article considers two alternate solutions of a heat balance equation. The first solution allows us to trace decrease of temperature of a flammable liquid (FL) surface to a temperature lower than fuel flash point at which combustion is stopped. And the second solution allows us to analyze decrease of burnout rate to a negligible value at which steam...

  1. Privacy Act System of Records: EPA Telecommunications Detail Records, EPA-32

    Science.gov (United States)

    Learn more about the EPA Telecommunications Detail Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  2. Quality system target on a detail design activity irradiator ISG 500

    International Nuclear Information System (INIS)

    Reinhard Pardede

    2010-01-01

    Currently, an engineering team of Nuclear Equipment Engineering Center PRPN has been beening technology innovation detail design of Irradiator ISG 500, then enter continuing to a construction phase. A schedule detail design still being not finish yet. The installation of Irradiator ISG 500 will be used to preservative the result of agricultural product in Indonesia. It is known as an export commodity and row material for food. However, its quality need some improvements in order to meet internal and foreign consumer standard. To enhance a quality system in detail design phase has already used ISO 9001: 2008 on clausul-7: Product Realization-design. It also needs a radioactive regulation Bapeten-Indonesian Nuclear Energy Surveillance Agency compliance with IAEA GS-R 3: 2006 as well. Scope of activity design is Instrumentation and Control system; Mechanical- Electrical; Radiation and Safety and Dosimetry; Civil Structured; Quality Assurance and Technoeconomic. Technology Innovating be applied to achieved economics through Costumer and Market Focused. Gamma irradiation of Irradiator ISG 500 can be used to improve hygienic quality in terms of technological as well as economical aspects. Technology innovation fit with the state of the arts right now. Assessment should be done base not only internal audit but also monitoring and surveillance as well. By application of a Quality System on detail design activity hopefully to enhance quality on detail design, construction, more over irradiator operation. (author)

  3. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  4. Design and Implementation of Fire Extinguisher Robot with Robotic Arm

    Directory of Open Access Journals (Sweden)

    Memon Abdul Waris

    2018-01-01

    Full Text Available Robot is a device, which performs human task or behave like a human-being. It needs expertise skills and complex programming to design. For designing a fire fighter robot, many sensors and motors were used. User firstly send robot to an affected area, to get live image of the field with the help of mobile camera via Wi-Fi using IP camera application to laptop. If any signs of fire shown in image, user direct robot in that particular direction for confirmation. Fire sensor and temperature sensor detects and measures the reading, after confirmation robot sprinkle water on affected field. During extinguish process if any obstacle comes in between the prototype and the affected area the ultrasonic sensor detects the obstacle, in response the robotic arm moves to pick and place that obstacle to another location for clearing the path. Meanwhile if any poisonous gas is present, the gas sensor detects and indicates by making alarm.

  5. Detailed Modeling of Distillation Technologies for Closed-Loop Water Recovery Systems

    Science.gov (United States)

    Allada, Rama Kumar; Lange, Kevin E.; Anderson, Molly S.

    2011-01-01

    Detailed chemical process simulations are a useful tool in designing and optimizing complex systems and architectures for human life support. Dynamic and steady-state models of these systems help contrast the interactions of various operating parameters and hardware designs, which become extremely useful in trade-study analyses. NASA?s Exploration Life Support technology development project recently made use of such models to compliment a series of tests on different waste water distillation systems. This paper presents efforts to develop chemical process simulations for three technologies: the Cascade Distillation System (CDS), the Vapor Compression Distillation (VCD) system and the Wiped-Film Rotating Disk (WFRD) using the Aspen Custom Modeler and Aspen Plus process simulation tools. The paper discusses system design, modeling details, and modeling results for each technology and presents some comparisons between the model results and recent test data. Following these initial comparisons, some general conclusions and forward work are discussed.

  6. Effects of Multiple Contexts and Context Similarity on the Renewal of Extinguished Conditioned Behaviour in an ABA Design with Humans

    Science.gov (United States)

    Balooch, Siavash Bandarian; Neumann, David L.

    2011-01-01

    The ABA renewal procedure involves pairing a conditional stimulus (CS) and an unconditional stimulus (US) in one context (A), presenting extinction trials of the CS alone in a second context (B), and nonreinforced test trials of the CS in the acquisition context (A). The renewal of extinguished conditioned behaviour is observed during test. The…

  7. Weapon System Requirements: Detailed Systems Engineering Prior to Product Development Positions Programs for Success

    Science.gov (United States)

    2016-11-01

    modified, replaced, or sustained by consumers or different manufacturers in addition to the manufacturer that developed the system. It also allows...WEAPON SYSTEM REQUIREMENTS Detailed Systems Engineering Prior to Product Development Positions Programs for Success...Engineering Prior to Product Development Positions Programs for Success Why GAO Did This Study Cost and schedule growth in DOD major defense

  8. Selection of detailed items for periodic safety review on PWR radwaste management system

    Energy Technology Data Exchange (ETDEWEB)

    Sung, K. B.; Ahn, Y. S.; Park, Y. S.; Kim, S. H.; Kim, J. T. [Korea Hydric and Nuclear Power Company, Taejon (Korea, Republic of)

    2003-10-01

    Selection of detailed-items for Periodic Safety Review on PWR radwaste management system, the main component could be faithfully clarified according to the purpose of establishment on each system and basic purpose. It is proper to select detailed-items those of radioactivities in the reactor coolant activity levels and the released volume of liquid and gaseous radioactive material on safety performance. It's also proper to select solid radwaste production quantities as detailed-item that it would be predict the next ten years trends after PSR.

  9. Radioactive contamination mapping system detailed design report

    International Nuclear Information System (INIS)

    Bauer, R.G.; O'Callaghan, P.B.

    1996-08-01

    The Hanford Site's 100 Area production reactors released radioactively and chemically contaminated liquids into the soil column. The primary source of the contaminated liquids was reactor coolant and various waste waters released from planned liquid discharges, as well as pipelines, pipe junctions, and retention basins leaking into the disposal sites. Site remediation involves excavating the contaminated soils using conventional earthmoving techniques and equipment, treating as appropriate, transporting the soils, and disposing the soils at ERDF. To support remediation excavation, disposal, and documentation requirements, an automated radiological monitoring system was deemed necessary. The RCMS (Radioactive Contamination Mapping System) was designed to fulfill this need. This Detailed Design Report provides design information for the RCMS in accordance with Bechtel Hanford, Inc. Engineering Design Project Instructions

  10. SEM Characterization of Extinguished Grains from Plasma-Ignited M30 Charges

    Science.gov (United States)

    Kinkennon, A.; Birk, A.; DelGuercio, M.; Kaste, P.; Lieb, R.; Newberry, J.; Pesce-Rodriguez, R.; Schroeder, M.

    2000-01-01

    M30 propellant grains that had been ignited in interrupted closed bomb experiments were characterize by scanning electron microscopy (SEM). Previous chemical analysis of extinguished grains had given no indications of plasma-propellant chemical interactions that could explain the increased burning rates that had been previously observed in full-pressure closed bomb experiments. (This does not mean that there is no unique chemistry occurring with plasma ignition. It may occur very early in the ignition event and then become obscured by the burning chemistry.) In this work, SEM was used to look at grain morphologies to determine if there were increases in the surface areas of the plasma-ignited grains which would contribute to the apparent increase in the burning rate. Charges were made using 30 propellant grains (approximately 32 grams) stacked in two tiers and in two concentric circles around a plastic straw. Each grain was notched so that, when the grains were expelled from the bomb during extinguishment, it could be determined in which tier and which circle each grain was originally packed. Charges were ignited in a closed bomb by either a nickel wire/Mylar-capillary plasma or black powder. The bomb contained a blowout disk that ruptured when the pressure reached 35 MPa, and the propellant was vented into a collection chamber packed with polyurethane foam. SEM analysis of the grains fired with a conventional black powder igniter showed no signs of unusual burning characteristics. The surfaces seemed to be evenly burned on the exteriors of the grains and in the perforations. Grains that had been subjected to plasma ignition, however, had pits, gouges, chasms, and cracks in the surfaces. The sides of the grains closest to the plasma had the greatest amount of damage, but even surfaces facing the outer wall of the bomb had small pits. The perforations contained gouges and abnormally burned regions (wormholes) that extended into the web. The SEM photos indicated that

  11. Perspective pulse devices and automatic systems fire explosive protection of the radioactive infected objects

    International Nuclear Information System (INIS)

    Zakhmatov, V.D.; Kozhemyakin, A.S.; Pyatova, A.V.

    1999-01-01

    The suppression of fires in Chernobyl zone has shown complete unprofitable of traditional fire engineering to work on is radioactive of the infected district. In this connection as effective ways extinguishive in object 'Shelter' alongside with known traditional means and the systems offer to apply more perspective pulse systems, based on use energy small practically safe charges of gunpowder or explosive substances, in particular. Pulse explosive cone extinguishive of the device various sizes

  12. Broken detailed balance and non-equilibrium dynamics in living systems: a review

    Science.gov (United States)

    Gnesotto, F. S.; Mura, F.; Gladrow, J.; Broedersz, C. P.

    2018-06-01

    Living systems operate far from thermodynamic equilibrium. Enzymatic activity can induce broken detailed balance at the molecular scale. This molecular scale breaking of detailed balance is crucial to achieve biological functions such as high-fidelity transcription and translation, sensing, adaptation, biochemical patterning, and force generation. While biological systems such as motor enzymes violate detailed balance at the molecular scale, it remains unclear how non-equilibrium dynamics manifests at the mesoscale in systems that are driven through the collective activity of many motors. Indeed, in several cellular systems the presence of non-equilibrium dynamics is not always evident at large scales. For example, in the cytoskeleton or in chromosomes one can observe stationary stochastic processes that appear at first glance thermally driven. This raises the question how non-equilibrium fluctuations can be discerned from thermal noise. We discuss approaches that have recently been developed to address this question, including methods based on measuring the extent to which the system violates the fluctuation-dissipation theorem. We also review applications of this approach to reconstituted cytoskeletal networks, the cytoplasm of living cells, and cell membranes. Furthermore, we discuss a more recent approach to detect actively driven dynamics, which is based on inferring broken detailed balance. This constitutes a non-invasive method that uses time-lapse microscopy data, and can be applied to a broad range of systems in cells and tissue. We discuss the ideas underlying this method and its application to several examples including flagella, primary cilia, and cytoskeletal networks. Finally, we briefly discuss recent developments in stochastic thermodynamics and non-equilibrium statistical mechanics, which offer new perspectives to understand the physics of living systems.

  13. Broken detailed balance and non-equilibrium dynamics in living systems: a review.

    Science.gov (United States)

    Gnesotto, F S; Mura, F; Gladrow, J; Broedersz, C P

    2018-03-05

    Living systems operate far from thermodynamic equilibrium. Enzymatic activity can induce broken detailed balance at the molecular scale. This molecular scale breaking of detailed balance is crucial to achieve biological functions such as high-fidelity transcription and translation, sensing, adaptation, biochemical patterning, and force generation. While biological systems such as motor enzymes violate detailed balance at the molecular scale, it remains unclear how non-equilibrium dynamics manifests at the mesoscale in systems that are driven through the collective activity of many motors. Indeed, in several cellular systems the presence of non-equilibrium dynamics is not always evident at large scales. For example, in the cytoskeleton or in chromosomes one can observe stationary stochastic processes that appear at first glance thermally driven. This raises the question how non-equilibrium fluctuations can be discerned from thermal noise. We discuss approaches that have recently been developed to address this question, including methods based on measuring the extent to which the system violates the fluctuation-dissipation theorem. We also review applications of this approach to reconstituted cytoskeletal networks, the cytoplasm of living cells, and cell membranes. Furthermore, we discuss a more recent approach to detect actively driven dynamics, which is based on inferring broken detailed balance. This constitutes a non-invasive method that uses time-lapse microscopy data, and can be applied to a broad range of systems in cells and tissue. We discuss the ideas underlying this method and its application to several examples including flagella, primary cilia, and cytoskeletal networks. Finally, we briefly discuss recent developments in stochastic thermodynamics and non-equilibrium statistical mechanics, which offer new perspectives to understand the physics of living systems.

  14. Wooden houses in detail. Holzhaeuser im Detail

    Energy Technology Data Exchange (ETDEWEB)

    Ruske, W. (ed.)

    1986-01-01

    Under the serial title 'Planning and construction of wooden houses', WEKA will publish a number of books of which this is the first. Details of design and construction are presented, e.g.: Details of modern one-family houses; Fundamentals of design and hints for planning of wooden houses and compact wooden structures; Constructional ecology, wood protection, thermal insulation, sound insulation; Modular systems for domestic buildings; The 'bookshelf-type' house at the Berlin International Construction Exhibition (IBA); Experience with do-it-yourself systems. With 439 figs.

  15. Hippocampus-driven feed-forward inhibition of the prefrontal cortex mediates relapse of extinguished fear

    DEFF Research Database (Denmark)

    Marek, Roger; Jin, Jingji; Goode, Travis D.

    2018-01-01

    The medial prefrontal cortex (mPFC) has been implicated in the extinction of emotional memories, including conditioned fear. We found that ventral hippocampal (vHPC) projections to the infralimbic (IL) cortex recruited parvalbumin-expressing interneurons to counter the expression of extinguished...... fear and promote fear relapse. Whole-cell recordings ex vivo revealed that optogenetic activation of vHPC input to amygdala-projecting pyramidal neurons in the IL was dominated by feed-forward inhibition. Selectively silencing parvalbumin-expressing, but not somatostatin-expressing, interneurons...... in the IL eliminated vHPC-mediated inhibition. In behaving rats, pharmacogenetic activation of vHPC→IL projections impaired extinction recall, whereas silencing IL projectors diminished fear renewal. Intra-IL infusion of GABA receptor agonists or antagonists, respectively, reproduced these effects. Together...

  16. Fire and fire extinguishment in silos. An experimental study[Storage of wood fuel pellets]; Brand och brandslaeckning i siloanlaeggningar. En experimentell studie

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Henry; Blomqvist, Per; Zhenghua Yan

    2007-01-15

    A series of four tests have been conducted with wood pellets stored in a reduced size silo. The tests were conducted in order to increase the knowledge on fire development, detection and extinction technique in silo fires. The project originated from a pre-study on the extinction of silo fires made for the Swedish Rescue Service Agency (SRV). The test silo was built of concrete rings, had a diameter of 1 m, and a height of almost 6 m, which gave a volume of 4.4 m{sup 3}. The silo was filled with wood pellets up to a height of 5 m. A local auto ignition was imitated by a coiled heating wire placed in the pellet bulk centrally in the silo and a self sustaining pyrolysis zone was established within one hour. The silo was instrumented with almost 100 thermocouples as a mean to follow the development of the pyrolysis zone and later the efficiency of the extinguishment. Gas analyses were further made, both in the top of the silo, and at four different levels in the pellet bulk. After 30 hours the extinguishment was initiated using nitrogen (N{sub 2}) and carbon dioxide (CO{sub 2}), respectively. The gas was injected into the bottom of the silo. Two tests were also conducted where gas injection was combined foam application in the top of the silo. The tests showed that the pyrolysis zone preferably spreads downwards in the silo, while moisture and pyrolysis gases form a wave that slowly spreads upwards. It was difficult to detect the fire before the main 'gas wave' reached the pellet surface in the silo top, and detection time was about 20 hours in these tests. The spread of the pyrolysis zone, downward, was even slower. The slow development is probably an explanation of why real silo fires often are rather extensive once discovered. Inerting the silo with either nitrogen or carbon dioxide worked out well in the tests. The gas must be in gas phase and slowly introduced into the silo, as close to the bottom as possible. An efficient extinction implies an air

  17. Performance Evaluation of the Combined Agent Fire Fighting System (CAFFS)

    National Research Council Canada - National Science Library

    Kalberer, Jennifer

    2003-01-01

    ... of the location. The Combined Agent Fire Fighting System (CAFFS) employs innovations in nozzle design, lightweight composites and combination agents to design a system with extinguishment capabilities of much larger ARFF vehicles...

  18. 46 CFR 193.15-1 - Application.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Application. 193.15-1 Section 193.15-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-1 Application. (a) The provisions of this...

  19. 46 CFR 76.17-90 - Installations contracted for prior to November 19, 1952.

    Science.gov (United States)

    2010-10-01

    ... they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and alterations may be made to the same standards as the original installation. (2) The... VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-90 Installations contracted...

  20. 46 CFR 95.17-90 - Installations contracted for prior to November 19, 1952.

    Science.gov (United States)

    2010-10-01

    ... and they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and alterations may be made to the same standards as the original installation. (2... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-90 Installations...

  1. 46 CFR 108.411 - Smoke detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Smoke detection system. 108.411 Section 108.411 Shipping... EQUIPMENT Fire Extinguishing Systems § 108.411 Smoke detection system. Each smoke accumulator in a smoke detection system must be located on the overhead of the compartment protected by the system in a location...

  2. 46 CFR 131.535 - Firefighting training and drills.

    Science.gov (United States)

    2010-10-01

    ...) Starting of fire pumps and use of a sufficient number of outlets to determine that the system is working... closure of each space protected by a fixed fire-extinguishing system. (d) Each fire drill must, as far as... details of training in fire fighting and of fire drills, must be entered in the vessel's official logbook...

  3. 46 CFR 108.405 - Fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire detection system. 108.405 Section 108.405 Shipping... EQUIPMENT Fire Extinguishing Systems § 108.405 Fire detection system. (a) Each fire detection system and each smoke detection system on a unit must— (1) Be approved by the Commandant; and (2) Have a visual...

  4. DNS with detailed and tabulated chemistry of engine relevant igniting systems

    NARCIS (Netherlands)

    Bekdemir, C.; Somers, L.M.T.; Goey, de L.P.H.

    2014-01-01

    Developments in modern engine technology are moving towards a regime with fuel injection uncoupled from combustion. Auto-ignition is an essential characteristic in these systems. The accurate prediction of this chemical process is of paramount importance. Tabulation techniques can provide a detailed

  5. 46 CFR 108.413 - Fusible element fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fusible element fire detection system. 108.413 Section... UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system. (a) A fusible element fire detection system may be installed. (b) The arrangements for the system...

  6. PC-based Multiple Information System Interface (PC/MISI) detailed design and implementation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Hall, Philip P.

    1985-01-01

    The design plan for the personal computer multiple information system interface (PC/MISI) project is discussed. The document is intended to be used as a blueprint for the implementation of the system. Each component is described in the detail necessary to allow programmers to implement the system. A description of the system data flow and system file structures is given.

  7. 46 CFR 108.404 - Selection of fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Selection of fire detection system. 108.404 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a... space. (b) The fire detection system must be designed to minimize false alarms. ...

  8. Development and Performance Evaluation of Image-Based Robotic Waxing System for Detailing Automobiles.

    Science.gov (United States)

    Lin, Chi-Ying; Hsu, Bing-Cheng

    2018-05-14

    Waxing is an important aspect of automobile detailing, aimed at protecting the finish of the car and preventing rust. At present, this delicate work is conducted manually due to the need for iterative adjustments to achieve acceptable quality. This paper presents a robotic waxing system in which surface images are used to evaluate the quality of the finish. An RGB-D camera is used to build a point cloud that details the sheet metal components to enable path planning for a robot manipulator. The robot is equipped with a multi-axis force sensor to measure and control the forces involved in the application and buffing of wax. Images of sheet metal components that were waxed by experienced car detailers were analyzed using image processing algorithms. A Gaussian distribution function and its parameterized values were obtained from the images for use as a performance criterion in evaluating the quality of surfaces prepared by the robotic waxing system. Waxing force and dwell time were optimized using a mathematical model based on the image-based criterion used to measure waxing performance. Experimental results demonstrate the feasibility of the proposed robotic waxing system and image-based performance evaluation scheme.

  9. 14 CFR 27.859 - Heating systems.

    Science.gov (United States)

    2010-01-01

    .... Except for heaters which incorporate designs to prevent hazards in the event of fuel leakage in the... locations ensuring prompt detection of fire in the heater region. (2) Fire extinguisher systems that provide... prevent the hazardous accumulation of water or ice on or in any heater control component, control system...

  10. The testing of the in situ fire extinction system of the Trawsfynydd splitter debris storage package

    International Nuclear Information System (INIS)

    Newman, R.N.

    1987-01-01

    The proposed design of a Magnox splitter debris storage drum for Trawsfynydd incorporates an in situ solid fire extinguishant Graphex CK23 on the debris surface. This is an interlamellar graphite residue compound that intumesces when heated to provide an air-restricting layer. Two series of fire tests with the extinguishant in place have been carried out on full sized drums containing unirradiated splitter debris, to demonstrate the effectiveness of the system. (author)

  11. Fire-Retardant, Self-Extinguishing Inorganic/Polymer Composite Memory Foams.

    Science.gov (United States)

    Chatterjee, Soumyajyoti; Shanmuganathan, Kadhiravan; Kumaraswamy, Guruswamy

    2017-12-27

    Polymeric foams used in furniture and automotive and aircraft seating applications rely on the incorporation of environmentally hazardous fire-retardant additives to meet fire safety norms. This has occasioned significant interest in novel approaches to the elimination of fire-retardant additives. Foams based on polymer nanocomposites or based on fire-retardant coatings show compromised mechanical performance and require additional processing steps. Here, we demonstrate a one-step preparation of a fire-retardant ice-templated inorganic/polymer hybrid that does not incorporate fire-retardant additives. The hybrid foams exhibit excellent mechanical properties. They are elastic to large compressional strain, despite the high inorganic content. They also exhibit tunable mechanical recovery, including viscoelastic "memory". These hybrid foams are prepared using ice-templating that relies on a green solvent, water, as a porogen. Because these foams are predominantly comprised of inorganic components, they exhibit exceptional fire retardance in torch burn tests and are self-extinguishing. After being subjected to a flame, the foam retains its porous structure and does not drip or collapse. In micro-combustion calorimetry, the hybrid foams show a peak heat release rate that is only 25% that of a commercial fire-retardant polyurethanes. Finally, we demonstrate that we can use ice-templating to prepare hybrid foams with different inorganic colloids, including cheap commercial materials. We also demonstrate that ice-templating is amenable to scale up, without loss of mechanical performance or fire-retardant properties.

  12. Detailed CATHENA Model of the Wolsong 1 Pressure and Inventory Control System

    Energy Technology Data Exchange (ETDEWEB)

    Cha, K.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    The Detailed CATHENA model of Wolsong 1 is development to be able to simulate a theramal hydraulic behavior of heat transport system(HTS) Pressure and Inventory Control System(PNIC) at any power operation condition and during transient events such as mall LOCA(small loss of coolant inventory and small breaks in the primary system piping) and non-LOCA(loss of reactivity regulation, loss of flow, loss if Class IV power, loss of PNIC). (author). 12 refs., 7 figs., 6 tabs.

  13. 46 CFR 108.407 - Detectors for electric fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Detectors for electric fire detection system. 108.407... DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.407 Detectors for electric fire detection system. (a) Each detector in an electric fire detection system must be located where— (1) No...

  14. Regulation No. 56/2006 Coll. of the Nuclear Regulatory Authority of the Slovak Republic dated as of January 12, 2006 on details concerning requirements for quality system documentation of authorisation holder, as well as details concerning quality requirements for nuclear installations, details concerning quality requirements for classified equipment and details concerning the scope of their approval

    International Nuclear Information System (INIS)

    2006-01-01

    This Regulation provides details of the requirements for quality system documentation holder, details of the quality requirements for nuclear installations, details concerning quality requirements for classified equipment and details of the scope of their approval. This Regulation came into force on March 1, 2006.

  15. Study of the physicochemical properties of an extinguishing powder for sodium fires: aging, fabrication, and mechanism of extinction

    International Nuclear Information System (INIS)

    Kusumanindyah, Nur-Andriani-Pramudita

    2016-01-01

    The French atomic and alternatives Energy Commission (CEA) developed an effective powder capable of extinguishing sodium fire. It is a powder based on a mixture of lithium carbonate (Li_2CO_3) and low-hydrated sodium carbonate (Na_2CO_3.H_2O) in a near eutectic proportion, with a melting temperature of around 500 C, associated with graphite. However, ever since the dismantling of several old sodium installations, CEA has at its disposal an important stock of unused powder batches. The idea of re-utilizing these powders initiates the question about their efficiency to extinguish a sodium fire after long term storage. This study proposed the physicochemical analyses of these powders in order to identify their compositions and characteristics for different batches. The results highlight the presence of lithium sodium carbonate (LiNaCO_3) and trona (Na_2CO_3.NaHCO_3.2H_2O), which are not mentioned in the patent. The aging experiments were developed to study the role of moisture and ambient carbon dioxide during the storage. The results showed that LiNaCO_3 is sensitive to the presence of moisture, able to transform it into lithium carbonate and sodium carbonate monohydrate, meanwhile the latter reacts with water and carbon dioxide to form trona. a study of the formation of LiNaCO_3 allowed the understanding of the fabrication method of the powder. This compound is found to be produced as the results of mechano-chemical reactions between Li_2CO_3 and Na_2CO_3.H_2O during the grinding process. The Chris(X)ti-Na experimental facility is built to understand the mechanisms of extinction especially related to the role of physicochemical properties on extinction. Two steps of extinction mechanisms are proposed that includes (1) the formation of liquid sodium hydroxide (NaOH) and (2) the melting of eutectic carbonates. The first step can happen directly (via the direct reaction of trona and/or Na_2CO_3.H_2O with Na(g) and/or Na_2O(s)) or indirectly (via the decomposition

  16. The Devil Is in the Details: Evidence from the GED on the Role of Examination System Details in Determining Who Passes. NCSALL Reports #16.

    Science.gov (United States)

    Tyler, John H.; Murnane, Richard J.; Willett, John B.

    A study used data from a long-standing examination system, the General Educational Development (GED) certificate, to illustrate that the details of examination systems have marked impacts on the number of test takers who obtain the desired credential and on the racial/ethnic composition of passers. Data provided by the Florida Department of…

  17. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to get ... Optical bus of centralized relay protection and automation system of medium voltage switchgear for data collection and transmission. Abstract PDF. ISSN: 1112- ...

  18. Hippocampus-driven feed-forward inhibition of the prefrontal cortex mediates relapse of extinguished fear.

    Science.gov (United States)

    Marek, Roger; Jin, Jingji; Goode, Travis D; Giustino, Thomas F; Wang, Qian; Acca, Gillian M; Holehonnur, Roopashri; Ploski, Jonathan E; Fitzgerald, Paul J; Lynagh, Timothy; Lynch, Joseph W; Maren, Stephen; Sah, Pankaj

    2018-03-01

    The medial prefrontal cortex (mPFC) has been implicated in the extinction of emotional memories, including conditioned fear. We found that ventral hippocampal (vHPC) projections to the infralimbic (IL) cortex recruited parvalbumin-expressing interneurons to counter the expression of extinguished fear and promote fear relapse. Whole-cell recordings ex vivo revealed that optogenetic activation of vHPC input to amygdala-projecting pyramidal neurons in the IL was dominated by feed-forward inhibition. Selectively silencing parvalbumin-expressing, but not somatostatin-expressing, interneurons in the IL eliminated vHPC-mediated inhibition. In behaving rats, pharmacogenetic activation of vHPC→IL projections impaired extinction recall, whereas silencing IL projectors diminished fear renewal. Intra-IL infusion of GABA receptor agonists or antagonists, respectively, reproduced these effects. Together, our findings describe a previously unknown circuit mechanism for the contextual control of fear, and indicate that vHPC-mediated inhibition of IL is an essential neural substrate for fear relapse.

  19. Influence of dispersion degree of water drops on efficiency of extinguishing of flammable liquids

    Directory of Open Access Journals (Sweden)

    Korolchenko Dmitriy

    2016-01-01

    Full Text Available Depending on the size of water drops, process of fire extinguishing is focused either in a zone of combustion or on a burning liquid surface. This article considers two alternate solutions of a heat balance equation. The first solution allows us to trace decrease of temperature of a flammable liquid (FL surface to a temperature lower than fuel flash point at which combustion is stopped. And the second solution allows us to analyze decrease of burnout rate to a negligible value at which steam-air mixture becomes nonflammable. As a result of solve of a heat balance equation it was made the following conclusion: water drops which size is equal to 100 μm will completely evaporate in a zone of combustion with extent of 1 m if the flying speed of drops is even 16 mps (acc. to Stokes v = 3 mps; whereas drops of larger size will evaporate only partially.

  20. Surface Accessibility with Spatial Analysis During Fire Extinguishing Procedures: Example on the Island of Vis

    Directory of Open Access Journals (Sweden)

    Kruno Lepoglavec

    2017-01-01

    Full Text Available Background and Purpose: The existing public and forest transport infrastructure (truck forest roads are permanent objects used when passing through forests. They also serve as a firefighter belt and provide direct access to firefighting vehicles, or are used as the starting point where firefighting teams extinguish fires or move toward remote fires. The paper identifies the existing fire road network (including public roads, forest roads, non-classified roads and fire roads for access of firefighting vehicles during fire extinguishing interventions. Material and Methods: An analysis of the intervention rate was conducted on a dispersive sample (35 positions from two volunteer fire associations (VFA on the island of Vis. Also, an analysis of the surface availability to fire vehicles concerning the time of departure from the fire station was conducted, as well as the comparison with the Standard time of intervention defined by the regulations on fire department organization in the Republic of Croatia. Results: For each simulated fire location for intervention of two existing volunteer fire associations: VFA Komiža and VFA Vis, results show that for a few fire locations, despite a smaller distance from the VFA Komiža, a quicker intervention is possible from the VFA Vis (locations 4, 5 and 14, and vice versa (locations 21, 22 and 25. With the use of a New Service Area, tool intervention times regarding different areas were calculated. Intervention times were divided into intervals: 25 min. The last two categories of area are beyond reach for firefighters within the Standard time of intervention (15 min and together they comprise to 27.88% of the total research area. Conclusions: The results of Closest Facility tool indicate that for the simulated fire position the best/fastest route is not always the shortest one, because of a significant effect of the structural elements of each road, the state of the road and the longitudinal slope of the road

  1. Effect of vacuum arc cathode spot distribution on breaking capacity of the arc-extinguishing chamber

    Science.gov (United States)

    Ding, Can; Yuan, Zhao; He, Junjia

    2017-10-01

    A DC circuit breaker performs a key function in breaking an intermediate-frequency (IF) current since breaking a pure IF current is equivalent to breaking a very small DC with a reverse IF current. In this study, it is found that cathode spots show a ring-shaped distribution at 2000 Hz. An arc with an uneven distribution of cathode spots has been simulated. The simulation results show that the distribution of cathode spots significantly affect the microparameter distribution of arc plasma. The current distribution on the anode side differs from that on the cathode side under the total radial electric field. Specifically, the anode current distribution is both uneven and concentrated. The applied axial magnetic field, which cannot reduce the concentrated anode current distribution effectively, might increase the concentration of the anode current. Finally, the uneven distribution of cathode spots reduces the breaking capacity of the arc-extinguishing chamber.

  2. Performance evaluation of contrast-detail in full field digital mammography systems using ideal (Hotelling) observer vs. conventional automated analysis of CDMAM images for quality control of contrast-detail characteristics.

    Science.gov (United States)

    Delakis, Ioannis; Wise, Robert; Morris, Lauren; Kulama, Eugenia

    2015-11-01

    The purpose of this work was to evaluate the contrast-detail performance of full field digital mammography (FFDM) systems using ideal (Hotelling) observer Signal-to-Noise Ratio (SNR) methodology and ascertain whether it can be considered an alternative to the conventional, automated analysis of CDMAM phantom images. Five FFDM units currently used in the national breast screening programme were evaluated, which differed with respect to age, detector, Automatic Exposure Control (AEC) and target/filter combination. Contrast-detail performance was analysed using CDMAM and ideal observer SNR methodology. The ideal observer SNR was calculated for input signal originating from gold discs of varying thicknesses and diameters, and then used to estimate the threshold gold thickness for each diameter as per CDMAM analysis. The variability of both methods and the dependence of CDMAM analysis on phantom manufacturing discrepancies also investigated. Results from both CDMAM and ideal observer methodologies were informative differentiators of FFDM systems' contrast-detail performance, displaying comparable patterns with respect to the FFDM systems' type and age. CDMAM results suggested higher threshold gold thickness values compared with the ideal observer methodology, especially for small-diameter details, which can be attributed to the behaviour of the CDMAM phantom used in this study. In addition, ideal observer methodology results showed lower variability than CDMAM results. The Ideal observer SNR methodology can provide a useful metric of the FFDM systems' contrast detail characteristics and could be considered a surrogate for conventional, automated analysis of CDMAM images. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Detailed Structural Analysis of Critical Wendelstein 7-X Magnet System Components

    International Nuclear Information System (INIS)

    Egorov, K.

    2006-01-01

    The Wendelstein 7-X (W7-X) stellarator experiment is presently under construction and assembly in Greifswald, Germany. The goal of the experiment is to verify that the stellarator magnetic confinement concept is a viable option for a fusion reactor. The complex W7-X magnet system requires a multi-level approach to structural analysis for which two types of finite element models are used: Firstly, global models having reasonably coarse meshes with a number of simplifications and assumptions, and secondly, local models with detailed meshes of critical regions and elements. Widely known sub-modelling technique with boundary conditions extracted from the global models is one of the approaches for local analysis with high assessment efficiency. In particular, the winding pack (WP) of the magnet coils is simulated in the global model as a homogeneous orthotropic material with effective mechanical characteristic representing its real composite structure. This assumption allows assessing the whole magnet system in terms of general structural factors like forces and moments on the support elements, displacements of the main components, deformation and stress in the coil casings, etc. In a second step local models with a detailed description of more critical WP zones are considered in order to analyze their internal components like conductor jackets, turn insulation, etc. This paper provides an overview of local analyses of several critical W7-X magnet system components with particular attention on the coil winding packs. (author)

  4. 46 CFR 108.467 - Water supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  5. Carbon dioxide not suitable for extinguishment of smouldering silo fires: static electricity may cause silo explosion

    DEFF Research Database (Denmark)

    Hedlund, Frank Huess

    2018-01-01

    argues that injection of inert carbon dioxide into the silo headspace is unsafe. Carbon dioxide is generally available as a liquid under high pressure. When discharged, small particles of dry ice are formed. The rapid flow of particles can generate considerable amounts of static electricity, which can...... act as a source of ignition if ignitable pyrolysis gasses are present. This article discusses a serious wood pellet smouldering fire and silo explosion in Norway in 2010, which took place when firefighters discharged portable CO2 fire extinguishers into the headspace. The attempt to suppress the fire...... may have ignited pyrolysis gasses. The article examines selected guidelines, standards, popular wood pellet handbooks and other literature and argues that the electrostatic hazard is widely under-appreciated. In the past, major explosions have been attributed to electrostatic ignition of flammable...

  6. Detailed Design of Cooling Water System for Cold Neutron Source in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Choi, Jung Woon; Kim, Y. K.; Wu, S. I.; Lee, Y. S

    2007-04-15

    To make cold neutron, a cryogenic refrigerator is necessary to transform moderator into cryogenic state so, thermal neutron is changed into cold neutron through heat transfer with moderator. A cryogenic refrigerator mainly consists of two apparatus, a helium compressor and a cold box which needs supply of cooling water. Therefore, cooling water system is essential to operate of cryogenic refrigerator normally. This report is mainly focused on the detailed design of the cooling water system for the HANARO cold neutron source, and describes design requirement, calculation, specification of equipment and water treatment method.

  7. Detailed Design of Cooling Water System for Cold Neutron Source in HANARO

    International Nuclear Information System (INIS)

    Kim, Bong Soo; Choi, Jung Woon; Kim, Y. K.; Wu, S. I.; Lee, Y. S.

    2007-04-01

    To make cold neutron, a cryogenic refrigerator is necessary to transform moderator into cryogenic state so, thermal neutron is changed into cold neutron through heat transfer with moderator. A cryogenic refrigerator mainly consists of two apparatus, a helium compressor and a cold box which needs supply of cooling water. Therefore, cooling water system is essential to operate of cryogenic refrigerator normally. This report is mainly focused on the detailed design of the cooling water system for the HANARO cold neutron source, and describes design requirement, calculation, specification of equipment and water treatment method

  8. 46 CFR 118.410 - Fixed gas fire extinguishing systems.

    Science.gov (United States)

    2010-10-01

    ... approved by the Commandant and protected from damage or accidental activation. A pull cable used to... outside against corrosion unless otherwise approved by the Commandant. Aluminum or other low melting... rotating electrical propulsion equipment a fixed carbon dioxide system must meet the following requirements...

  9. 46 CFR 108.463 - Foam rate: Protein.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Foam rate: Protein. 108.463 Section 108.463 Shipping... EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.463 Foam rate: Protein. (a) If the outlets of a protein foam extinguishing system are in a space, the foam rate at each outlet must be at...

  10. Advanced information processing system: The Army Fault-Tolerant Architecture detailed design overview

    Science.gov (United States)

    Harper, Richard E.; Babikyan, Carol A.; Butler, Bryan P.; Clasen, Robert J.; Harris, Chris H.; Lala, Jaynarayan H.; Masotto, Thomas K.; Nagle, Gail A.; Prizant, Mark J.; Treadwell, Steven

    1994-01-01

    The Army Avionics Research and Development Activity (AVRADA) is pursuing programs that would enable effective and efficient management of large amounts of situational data that occurs during tactical rotorcraft missions. The Computer Aided Low Altitude Night Helicopter Flight Program has identified automated Terrain Following/Terrain Avoidance, Nap of the Earth (TF/TA, NOE) operation as key enabling technology for advanced tactical rotorcraft to enhance mission survivability and mission effectiveness. The processing of critical information at low altitudes with short reaction times is life-critical and mission-critical necessitating an ultra-reliable/high throughput computing platform for dependable service for flight control, fusion of sensor data, route planning, near-field/far-field navigation, and obstacle avoidance operations. To address these needs the Army Fault Tolerant Architecture (AFTA) is being designed and developed. This computer system is based upon the Fault Tolerant Parallel Processor (FTPP) developed by Charles Stark Draper Labs (CSDL). AFTA is hard real-time, Byzantine, fault-tolerant parallel processor which is programmed in the ADA language. This document describes the results of the Detailed Design (Phase 2 and 3 of a 3-year project) of the AFTA development. This document contains detailed descriptions of the program objectives, the TF/TA NOE application requirements, architecture, hardware design, operating systems design, systems performance measurements and analytical models.

  11. Underground fires in oil shale mines: special traits of their spreading, extinguishing and liquidating of consequences

    International Nuclear Information System (INIS)

    Parakhonsky, E.

    1995-01-01

    Danger of catching fire in oil shale underground mines has considerably increased lately because of essential increase in mechanization level and frequent violation of fire-safety regulations. The largest underground fire in Estonia took place in the most mechanized mine 'Estonia' in the end of 1988 and lasted 81 days. The fire started in one of the conveyor drifts where two belt-conveyors with rubber-rope belts and a fire pipeline were installed. At the start of the fire and beginning of extinguishing work this pipeline contained no water. Driving heads of these conveyors were installed with automatic extinguishing equipment and with different primary means against fire. When the first group of the Johvi military mine-rescue squad reached the mine they established that the conveyor drift, pillars and a part of rail drift between them were caught by fire. The conveyor belt, oil shale and feeds of conveyor drives were burning. The flame had propagated about 350 metres along the rail and conveyor drifts but the smoke had spread 4 kilometres already. Air temperature near the burning area was about 40-60 deg C, rocks from the roof supported by pillars had crashed down. The mine air was polluted by combustion products. The fire caused a noticeable pollution of mine and surface waters with phenols formed at oil shale combustion. Their limit concentration was exceeded for more than 400 times. To decrease this number, an intensive saturation of waters with atmosphere air was started. For this purpose special dams were constructed on water-diversion ditches ensuring a 0.5-0.7 m difference in water levels. Nevertheless, the phenol concentration in Rannapungerya River and Lake Peipsi still exceeded the normal level 5-6 times. However, the actual maximum concentration of phenols was considerably lower than the lethal doses for fish and other water organisms. Their mass extinction in the river or in the lake was observed neither during nor after the fire. One may conclude the

  12. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Science.gov (United States)

    2010-10-01

    ... oil units, valves, or manifolds in the line between the settling tanks and the boilers. (e) Fire... approved system must be installed in all cargo compartments and tanks for combustible cargo, except for vessels engaged exclusively in the carriage of coal or grain in bulk. For cargo compartments and tanks...

  13. Detailed requirements document for the Interactive Financial Management System (IFMS), volume 1

    Science.gov (United States)

    Dodson, D. B.

    1975-01-01

    The detailed requirements for phase 1 (online fund control, subauthorization accounting, and accounts receivable functional capabilities) of the Interactive Financial Management System (IFMS) are described. This includes information on the following: systems requirements, performance requirements, test requirements, and production implementation. Most of the work is centered on systems requirements, and includes discussions on the following processes: resources authority, allotment, primary work authorization, reimbursable order acceptance, purchase request, obligation, cost accrual, cost distribution, disbursement, subauthorization performance, travel, accounts receivable, payroll, property, edit table maintenance, end-of-year, backup input. Other subjects covered include: external systems interfaces, general inquiries, general report requirements, communication requirements, and miscellaneous. Subjects covered under performance requirements include: response time, processing volumes, system reliability, and accuracy. Under test requirements come test data sources, general test approach, and acceptance criteria. Under production implementation come data base establishment, operational stages, and operational requirements.

  14. Author Details

    African Journals Online (AJOL)

    Warnorff, DK. Vol 13, No 4 (2001) - Articles Development of a scoring system for the diagnosis of tuberculous lymphadenitis. Details PDF. ISSN: 1995-7262. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions ...

  15. 46 CFR 108.471 - Water pump.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  16. Ground System Survivability Overview

    Science.gov (United States)

    2012-03-27

    Avoidance Blast Mitigation Optimization Customer ILIR RDT&E Funding 5.0 % 0.5% GSS has a proven, technically proficient workforce that meets...Evaluation of Defensive-Aid Suites (ARMED) Common Automatic Fire Extinguishing System ( CAFES ) Transparent Armor Development Ground Combat Vehicle...Survey TRADOC (WFO, CNA, etc) Voice of the Customer Sy st em s En gi ne er in g Publish overarching MIL-STD, design guidelines, technical

  17. Detailed performance analysis of realistic solar photovoltaic systems at extensive climatic conditions

    International Nuclear Information System (INIS)

    Gupta, Ankit; Chauhan, Yogesh K.

    2016-01-01

    In recent years, solar energy has been considered as one of the principle renewable energy source for electric power generation. In this paper, single diode photovoltaic (PV) system and double/bypass diode based PV system are designed in MATLAB/Simulink environment based on their mathematical modeling and are validated with a commercially available solar panel. The novelty of the paper is to include the effect of climatic conditions i.e. variable irradiation level, wind speed, temperature, humidity level and dust accumulation in the modeling of both the PV systems to represent a realistic PV system. The comprehensive investigations are made on both the modeled PV systems. The obtained results show the satisfactory performance for realistic models of the PV system. Furthermore, an in depth comparative analysis is carried out for both PV systems. - Highlights: • Modeling of Single diode and Double diode PV systems in MATLAB/Simulink software. • Validation of designed PV systems with a commercially available PV panel. • Acquisition and employment of key climatic factors in modeling of the PV systems. • Evaluation of main model parameters of both the PV systems. • Detailed comparative assessment of both the modeled PV system parameters.

  18. Implementation of a next-generation electronic nursing records system based on detailed clinical models and integration of clinical practice guidelines.

    Science.gov (United States)

    Min, Yul Ha; Park, Hyeoun-Ae; Chung, Eunja; Lee, Hyunsook

    2013-12-01

    The purpose of this paper is to describe the components of a next-generation electronic nursing records system ensuring full semantic interoperability and integrating evidence into the nursing records system. A next-generation electronic nursing records system based on detailed clinical models and clinical practice guidelines was developed at Seoul National University Bundang Hospital in 2013. This system has two components, a terminology server and a nursing documentation system. The terminology server manages nursing narratives generated from entity-attribute-value triplets of detailed clinical models using a natural language generation system. The nursing documentation system provides nurses with a set of nursing narratives arranged around the recommendations extracted from clinical practice guidelines. An electronic nursing records system based on detailed clinical models and clinical practice guidelines was successfully implemented in a hospital in Korea. The next-generation electronic nursing records system can support nursing practice and nursing documentation, which in turn will improve data quality.

  19. Usability Assessment of Text-to-Speech Synthesis for Additional Detail in an Automated Telephone Banking System

    OpenAIRE

    Morton , Hazel; Gunson , Nancie; Marshall , Diarmid; McInnes , Fergus; Ayres , Andrea; Jack , Mervyn

    2010-01-01

    Abstract This paper describes a comprehensive usability evaluation of an automated telephone banking system which employs text-to-speech (TTS) synthesis in offering additional detail on customers? account transactions. The paper describes a series of four experiments in which TTS was employed to offer an extra level of detail to recent transactions listings within an established banking service which otherwise uses recorded speech from a professional recording artist. Results from ...

  20. 46 CFR 76.50-5 - Classification.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Classification. 76.50-5 Section 76.50-5 Shipping COAST... Classification. (a) Hand portable fire extinguishers and semiportable fire extinguishing systems shall be... extinguishing systems are set forth in table 76.50-5(c). Table 76.50-5(c) Classification Type Size Soda acid and...

  1. Chronic treatment with fluoxetine prevents the return of extinguished auditory-cued conditioned fear.

    Science.gov (United States)

    Deschaux, Olivier; Spennato, Guillaume; Moreau, Jean-Luc; Garcia, René

    2011-05-01

    We have recently shown that post-extinction exposure of rats to a sub-threshold reminder shock can reactivate extinguished context-related freezing and found that chronic treatment with fluoxetine before fear extinction prevents this phenomenon. In the present study, we examined whether these findings would be confirmed with auditory fear conditioning. Rats were initially submitted to a session of five tone-shock pairings with either a 0.7- or 0.1-mA shock and underwent, 3 days later, a session of 20 tone-alone trials. At the beginning of this latter session, we observed cue-conditioned freezing in rats that received the strong, but not the weak, shock. At the end, both groups (strong and weak shocks) displayed similar low levels of freezing, indicating fear extinction in rats exposed to the strong shock. These rats exhibited again high levels of cue-evoked freezing when exposed to three tone-shock pairings with 0.1-mA shock. This reemergence of cue-conditioned fear was completely abolished by chronic (over a 21-day period) fluoxetine treatment which spared, when administered before the initial fear conditioning, the original tone-shock association. These data extend our previous findings and suggest that chronic fluoxetine treatment favor extinction memory by dampening the reactivation of the original tone-shock association.

  2. 46 CFR 108.437 - Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. 108.437 Section 108.437 Shipping COAST GUARD, DEPARTMENT OF... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for...

  3. Detail Design of the hydrogen system and the gas blanketing system for the HANARO-CNS

    International Nuclear Information System (INIS)

    Choi, Jung Woon; Kim, Hark Rho; Kim, Young Ki; Wu, Sang Ik; Kim, Bong Su; Lee, Yong Seop

    2007-04-01

    The cold neutron source (CNS), which will be installed in the vertical CN hole of the reflector tank at HANARO, makes thermal neutrons to moderate into the cold neutrons with the ranges of 0.1 ∼ 10 meV passing through a moderator at about 22K. A moderator to produce cold neutrons is liquid hydrogen, which liquefies by the heat transfer with cryogenic helium flowing from the helium refrigeration system (HRS). Because of its installed location, the hydrogen system is designed to be surrounded by the gas blanketing system to notify the leakage on the system and to prevent hydrogen leakage out of the CNS. The hydrogen system, consisted of hydrogen charging unit, hydrogen storage unit, hydrogen buffer tank, and hydrogen piping, is designed to smoothly and safely supply hydrogen to and to draw back hydrogen from the IPA of the CNS under the HRS operation mode. Described is that calculation for total required hydrogen amount in the CNS as well as operation schemes of the hydrogen system. The gas blanketing system (GBS) is designed for the supply of the compressed nitrogen gas into the air pressurized valves for the CNS, to isolate the hydrogen system from the air and the water, and to prevent air or water intrusion into the vacuum system as well as the hydrogen system. All detail descriptions are shown inhere as well as the operation scheme for the GBS

  4. E-detailing: information technology applied to pharmaceutical detailing.

    Science.gov (United States)

    Montoya, Isaac D

    2008-11-01

    E-detailing can be best described as the use of information technology in the field of pharmaceutical detailing. It is becoming highly popular among pharmaceutical companies because it maximizes the time of the sales force, cuts down the cost of detailing and increases physician prescribing. Thus, the application of information technology is proving to be beneficial to both physicians and pharmaceutical companies. When e-detailing was introduced in 1996, it was limited to the US; however, numerous other countries soon adopted this novel approach to detailing and now it is popular in many developed nations. The objective of this paper is to demonstrate the rapid growth of e-detailing in the field of pharmaceutical marketing. A review of e-detailing literature was conducted in addition to personal conversations with physicians. E-detailing has the potential to reduce marketing costs, increase accessibility to physicians and offer many of the advantages of face-to-face detailing. E-detailing is gaining acceptance among physicians because they can access the information of a pharmaceutical product at their own time and convenience. However, the drug safety aspect of e-detailing has not been examined and e-detailing remains a supplement to traditional detailing and is not yet a replacement to it.

  5. SU-F-P-01: Changing Your Oncology Information System: A Detailed Process and Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Abing, C [Gundersen Lutheran Medical Center, La Crosse, WI (United States)

    2016-06-15

    Purpose: Radiation Oncology departments are faced with many options for pairing their treatment machines with record and verify systems. Recently, there is a push to have a single-vendor-solution. In order to achieve this, the department must go through an intense and rigorous transition process. Our department has recently completed this process and now offer a detailed description of the process along with lessons learned. Methods: Our cancer center transitioned from a multi-vendor department to a single-vendor department over the 2015 calendar year. Our staff was partitioned off into superuser groups, an interface team, migration team, and go-live team. Six months after successful implementation, a detailed survey was sent to the radiation oncology department to determine areas for improvement as well as successes in the process. Results: The transition between record and verify systems was considered a complete success. The results of the survey did point out some areas for improving inefficiencies with our staff; both interactions between each other and the vendors. Conclusion: Though this process was intricate and lengthy, it can be made easier with careful planning and detailed designation of project responsibilities. Our survey results and retrospective analysis of the transition are valuable to those wishing to make this change.

  6. GIS-assisted spatial analysis for urban regulatory detailed planning: designer's dimension in the Chinese code system

    Science.gov (United States)

    Yu, Yang; Zeng, Zheng

    2009-10-01

    By discussing the causes behind the high amendments ratio in the implementation of urban regulatory detailed plans in China despite its law-ensured status, the study aims to reconcile conflict between the legal authority of regulatory detailed planning and the insufficient scientific support in its decision-making and compilation by introducing into the process spatial analysis based on GIS technology and 3D modeling thus present a more scientific and flexible approach to regulatory detailed planning in China. The study first points out that the current compilation process of urban regulatory detailed plan in China employs mainly an empirical approach which renders it constantly subjected to amendments; the study then discusses the need and current utilization of GIS in the Chinese system and proposes the framework of a GIS-assisted 3D spatial analysis process from the designer's perspective which can be regarded as an alternating processes between the descriptive codes and physical design in the compilation of regulatory detailed planning. With a case study of the processes and results from the application of the framework, the paper concludes that the proposed framework can be an effective instrument which provides more rationality, flexibility and thus more efficiency to the compilation and decision-making process of urban regulatory detailed plan in China.

  7. Space Telecommunications Radio System (STRS) Architecture, Tutorial Part 2 - Detailed

    Science.gov (United States)

    Handler, Louis

    2014-01-01

    The STRS architecture detail presentation presents each requirement in the STRS Architecture Standard with some examples and supporting information. The purpose is to give a platform provider, application provider, or application integrator a better, more detailed understanding of the STRS Architecture Standard and its use.

  8. 46 CFR 34.05-5 - Fire-extinguishing systems-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... subparagraph. (3) Lamp and paint lockers and similar spaces. A carbon dioxide or water spray system must be installed in all lamp and paint lockers, oil rooms, and similar spaces. (4) Pump rooms. A carbon dioxide..., etc., that are subject to the discharge pressure of the fuel oil service pumps. (6) Machinery spaces...

  9. CMHC research project: Testing of air barrier construction details, II: Report

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    Air leakage control through the building envelope of wood framed houses is more important than ever. The leakage of air is controlled by the air barrier system. There are several new technologies to construct an air barrier system for the building envelope. These are the Poly Approach, the Air Drywall Approach and the EASE system. The development of these systems was undertaken primarily by the building community without significant research and development. The purpose of this study was to determine the actual performance of several different types of construction details for each of the different approaches. Each of these details was designed and constructed using one of the air barrier methods and tested in the laboratory. The test details included the sill plate, the partition wall, the stair stringer, the electrical outlets, the bathtub detail, the plumbing stack detail, the metal chimney detail, the bathroom fan detail and the EASE wall system.

  10. Chemistry fighting against fires

    International Nuclear Information System (INIS)

    Raffalsky, K.

    1975-01-01

    A detailed report is given on the general principle 'fire' and on fires as fast chemical reactions between consumable material and oxygen of the air (exothermal oxidation) as well as on the classes of fires A to D. Class D includes strongly incadescent burnable metals such as K, Na, Li, Cs, Rb, U, Pu, Ce, Zr, Be, Ca, Sr, Ba etc. The burning process, the extinguishing effects, the development of the extinguisher and its present state are individually dealt with. (HK/LH) [de

  11. OECD-FIRE PR02. Summary report to finalize project stage 1 (2002-2005)

    International Nuclear Information System (INIS)

    Kolar, L.

    2005-12-01

    The report is structured as follows: (1) Project background; (2) Project goals; (3) Project infrastructure; (4) Database scope; (5) Data collection history and current status; (6) Database structure; (7) Statistical observations; (8) Conclusions. The following data are presented in graphs: Fire extinguishing database; Building (site) of fire incidence and total number of incidences in the database; Component on which fire was initiated; Mechanism of combustion; Root cause of the fire; Fire detection types; Technical data of the fire detection system; Fire detector type; Fuel/flammable material/fire load; Fire extinguishing type; Technical data of the fire extinguishing system; Who extinguished the fire; Fire consequences. (P.A.)

  12. Influences on physicians' adoption of electronic detailing (e-detailing).

    Science.gov (United States)

    Alkhateeb, Fadi M; Doucette, William R

    2009-01-01

    E-detailing means using digital technology: internet, video conferencing and interactive voice response. There are two types of e-detailing: interactive (virtual) and video. Currently, little is known about what factors influence physicians' adoption of e-detailing. The objectives of this study were to test a model of physicians' adoption of e-detailing and to describe physicians using e-detailing. A mail survey was sent to a random sample of 2000 physicians practicing in Iowa. Binomial logistic regression was used to test the model of influences on physician adoption of e-detailing. On the basis of Rogers' model of adoption, the independent variables included relative advantage, compatibility, complexity, peer influence, attitudes, years in practice, presence of restrictive access to traditional detailing, type of specialty, academic affiliation, type of practice setting and control variables. A total of 671 responses were received giving a response rate of 34.7%. A total of 141 physicians (21.0%) reported using of e-detailing. The overall adoption model for using either type of e-detailing was found to be significant. Relative advantage, peer influence, attitudes, type of specialty, presence of restrictive access and years of practice had significant influences on physician adoption of e-detailing. The model of adoption of innovation is useful to explain physicians' adoption of e-detailing.

  13. Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications

    Energy Technology Data Exchange (ETDEWEB)

    Makhmalbaf, Atefe; Fuller, Jason C.; Srivastava, Viraj; Ciraci, Selim; Daily, Jeffrey A.

    2014-12-24

    Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced

  14. Factors influencing detail detectability in radiologic imaging

    International Nuclear Information System (INIS)

    Gurvich, A.M.

    1985-01-01

    The detectability of various details is estimated quantitatively from the essential technical parameters of the imaging system and additional influencing factors including viewing of the image. The analysis implies the formation of the input radiation distribution (contrast formation, influence of kVp). Noise, image contrast (gamma), modulation transfer function and contrast threshold of the observer are of different influence on details of different size. Thus further optimization of imaging systems and their adaption to specific imaging tasks are facilitated

  15. The Hypocretin/Orexin System Mediates the Extinction of Fear Memories

    OpenAIRE

    Flores, África; Valls-Comamala, Victòria; Costa, Giulia; Saravia, Rocío; Maldonado, Rafael; Berrendero, Fernando

    2014-01-01

    Anxiety disorders are often associated with an inability to extinguish learned fear responses. The hypocretin/orexin system is involved in the regulation of emotional states and could also participate in the consolidation and extinction of aversive memories. Using hypocretin receptor-1 and hypocretin receptor-2 antagonists, hypocretin-1 and hypocretin-2 peptides, and hypocretin receptor-1 knockout mice, we investigated the role of the hypocretin system in cue- and context-dependent fear condi...

  16. The detail is dead - long live the detail!

    DEFF Research Database (Denmark)

    Larsen, Steen Nepper; Dalgaard, Kim; Kerstens, Vencent

    2018-01-01

    architecture when we look into architectural history. Too classic examples are; Adolf Loos who provoked already in 1908 with his statement; "Ornament and Crime", which contested the unconscious decorations of contemporary architects. Similarly, referring to the little need for superfluous detailing; "Less...... not change the fact that it is more important than ever to bring this 'small' architectural world to attention. Today, the construction industry is dictated by an economic management that does not leave much room for thorough studies of architectural details or visionary experiments. Today's more efficient......_Delft about the Symposium; "The Detail is Dead - Long Live the Detail". For this occasion a number of leading Danish and Northern European architects, researchers and companies were invited to discuss and suggest their 'architectural detail' and the challenges they face in today's construction. This book...

  17. Evaluation of SF6-alternative gas C5-PFK based on arc extinguishing performance and electric strength

    Science.gov (United States)

    Wu, Yi; Wang, Chunlin; Sun, Hao; Rong, Mingzhe; Murphy, Anthony Bruce; Li, Tianwei; Zhong, Jianying; Chen, Zhexin; Yang, Fei; Niu, Chunpin

    2017-09-01

    C5-PFK (C5-perfluoroketone, C5F10O) is under wide consideration as an environmentally-friendly alternative gas to SF6 in high-voltage applications, because of its superior insulation performance. The aim of this work is to study theoretically the arc extinguishing performance and electric strength of C5-PFK. The arc extinguishing performance of C5-PFK was evaluated by analyzing and comparing the thermophysical properties of C5-PFK, SF6, CF4, CO2 and N2 plasmas. It was difficult to obtain the species formed in C5-PFK plasmas because of the complex C5-PFK molecular decomposition process. In this work, the decomposition process of C5-PFK and the related species were analyzed by the bond energy analysis method. For the species for which parameters such as the partition function and the enthalpy of formation were not available, computational chemistry methods were used to obtain the required data. The collision integrals were calculated using the phenomenological potential model. Using these results, the local thermodynamic equilibrium composition at temperatures from 300 to 30 000 K at 1-10 atm of pure C5-PFK was calculated by the method of minimization of the Gibbs free energy, and the corresponding transport coefficients were calculated by Chapman-Enskog method. Through the comparison of the thermophysical properties, it was found that C5-PFK had similar characteristics to SF6, with large peaks in specific heat below 4500 K, indicating potentially good thermal interruption capability. However, the specific heat peak at 7000 K corresponding to CO decomposition may detract from the thermal interruption capability. Specific heat peaks at higher temperatures are associated with the breaking of double or triple bonds, and should be avoided if possible in the new alternative gases. The electric strength of C5-PFK was assessed using the molecular electrostatic potential, which can be accurately calculated or measured, and gives strong insights into important

  18. Investigation of sodium area conflagrations and testing of a protective system

    Energy Technology Data Exchange (ETDEWEB)

    Huber, F; Menzenhauer, P; Peppler, W [Kernforschungszentrum Karlsruhe (F.R. Germany). Inst. fuer Reaktorentwicklung

    1975-12-01

    During research and development work on the SNR-300 sodium-cooled fast reactor the consequences and confinement of sodium fires occurring in enclosures were studied. The behavior of liquid sodium during fires and the behavior of an inherently ready-for-operation protective system are described. Theoretical considerations on the behavior of burning liquid sodium are compared with experimental results. A protective system for large facilities is presented and the use of extinguishing powders is reviewed.

  19. Detailed study of grooved heat pipes for a system functioning study; Etude fine des caloducs rainures en vue d`une etude systeme

    Energy Technology Data Exchange (ETDEWEB)

    Alexandre, A [Ecole Nationale Superieure de Mecanique et d` Aerotechnique (ENSMA), 86 - Poitiers (France)

    1997-12-31

    The functioning of a heat pipe is complex. In this paper, a methodology for a detailed analysis of the functioning of a grooved heat pipe is developed in order to obtain the information required for a general analysis of such systems. (J.S.) 3 refs.

  20. Detailed study of grooved heat pipes for a system functioning study; Etude fine des caloducs rainures en vue d`une etude systeme

    Energy Technology Data Exchange (ETDEWEB)

    Alexandre, A. [Ecole Nationale Superieure de Mecanique et d`Aerotechnique (ENSMA), 86 - Poitiers (France)

    1996-12-31

    The functioning of a heat pipe is complex. In this paper, a methodology for a detailed analysis of the functioning of a grooved heat pipe is developed in order to obtain the information required for a general analysis of such systems. (J.S.) 3 refs.

  1. 46 CFR 108.443 - Controls and valves.

    Science.gov (United States)

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and valves. (a) At least one control for operating a CO2 system must be outside the space or spaces that the...

  2. Detailed Design Documentation, without the Pain

    Science.gov (United States)

    Ramsay, C. D.; Parkes, S.

    2004-06-01

    Producing detailed forms of design documentation, such as pseudocode and structured flowcharts, to describe the procedures of a software system:(1) allows software developers to model and discuss their understanding of a problem and the design of a solution free from the syntax of a programming language,(2) facilitates deeper involvement of non-technical stakeholders, such as the customer or project managers, whose influence ensures the quality, correctness and timeliness of the resulting system,(3) forms comprehensive documentation of the system for its future maintenance, reuse and/or redeployment.However, such forms of documentation require effort to create and maintain.This paper describes a software tool which is currently being developed within the Space Systems Research Group at the University of Dundee which aims to improve the utility of, and the incentive for, creating detailed design documentation for the procedures of a software system. The rationale for creating such a tool is briefly discussed, followed by a description of the tool itself, a summary of its perceived benefits, and plans for future work.

  3. Fatigue-Prone Details in Steel Bridges

    Directory of Open Access Journals (Sweden)

    Mohsen Heshmati

    2012-11-01

    Full Text Available This paper reviews the results of a comprehensive investigation including more than 100 fatigue damage cases, reported for steel and composite bridges. The damage cases are categorized according to types of detail. The mechanisms behind fatigue damage in each category are identified and studied. It was found that more than 90% of all reported damage cases are of deformation-induced type and generated by some kind of unintentional or otherwise overlooked interaction between different load-carrying members or systems in the bridge. Poor detailing, with unstiffened gaps and abrupt changes in stiffness at the connections between different members were also found to contribute to fatigue cracking in many details.

  4. Author Details

    African Journals Online (AJOL)

    Details PDF · Vol 22, No 2 (1999) - Articles Vegetation under different tree species in Acacia woodland in the Rift Valley of Ethiopia Details PDF · Vol 22, No 2 (1999) - Articles Preliminary evaluation of Phytomyza orobanchia (Diptera: Agromyzidae) as a controller of Orobanche spp in Ethiopia Details PDF. ISSN: 2520–7997.

  5. Sewerage Mapping and Information System of the Metropolis of Tokyo (SEMIS) : Details of the Development and Outline of the System

    Science.gov (United States)

    Kawakami, Kouichi; Sekita, Mitsunobu

    It is essential to manage sewerage ledgers as information when maintaining and controlling sewerage, one of the infrastructures of cities. The Bureau of Sewerage developed the full scale Sewerage Mapping and Information System (SEMIS), the first trial done by a local government in this country and has operated it since 1985. Before the development the questionnaires were conducted to survey the use of sewerage ledgers by staffs engaged in sewage works, and means of improving how to prepare plans of sewerage were considered based on them. Employing these means the Bureau made a database of plans and descriptions which comprise sewerage ledgers, and then constructed the computer system which manages it comprehensively. The details of the development and the system outline are described.

  6. Derivation of Markov processes that violate detailed balance

    Science.gov (United States)

    Lee, Julian

    2018-03-01

    Time-reversal symmetry of the microscopic laws dictates that the equilibrium distribution of a stochastic process must obey the condition of detailed balance. However, cyclic Markov processes that do not admit equilibrium distributions with detailed balance are often used to model systems driven out of equilibrium by external agents. I show that for a Markov model without detailed balance, an extended Markov model can be constructed, which explicitly includes the degrees of freedom for the driving agent and satisfies the detailed balance condition. The original cyclic Markov model for the driven system is then recovered as an approximation at early times by summing over the degrees of freedom for the driving agent. I also show that the widely accepted expression for the entropy production in a cyclic Markov model is actually a time derivative of an entropy component in the extended model. Further, I present an analytic expression for the entropy component that is hidden in the cyclic Markov model.

  7. 30 CFR 57.6202 - Vehicles.

    Science.gov (United States)

    2010-07-01

    ... in progress; and (8) Secured while parked by having— (i) The brakes set; (ii) The wheels chocked if... multipurpose dry-chemical fire extinguishers or one such extinguisher and an automatic fire suppression system...

  8. 46 CFR 108.493 - Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location. 108.493 Section 108.493 Shipping COAST GUARD... Extinguishing Systems Hand Portable and Semiportable Fire Extinguishing Systems § 108.493 Location. (a) Each... this subpart and installed in the locations prescribed in the table. (b) Each portable and semi...

  9. 78 FR 56597 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Science.gov (United States)

    2013-09-13

    ... extinguishing system injection tubes during an engine fire, which could result in impaired distribution of the... injection tubes. This AD is prompted by a report that the injection tubes are deforming due to heat. The actions required by this AD are intended to prevent deformation of the fire extinguishing system injection...

  10. Detailed Modeling and Irreversible Transfer Process Analysis of a Multi-Element Thermoelectric Generator System

    Science.gov (United States)

    Xiao, Heng; Gou, Xiaolong; Yang, Suwen

    2011-05-01

    Thermoelectric (TE) power generation technology, due to its several advantages, is becoming a noteworthy research direction. Many researchers conduct their performance analysis and optimization of TE devices and related applications based on the generalized thermoelectric energy balance equations. These generalized TE equations involve the internal irreversibility of Joule heating inside the thermoelectric device and heat leakage through the thermoelectric couple leg. However, it is assumed that the thermoelectric generator (TEG) is thermally isolated from the surroundings except for the heat flows at the cold and hot junctions. Since the thermoelectric generator is a multi-element device in practice, being composed of many fundamental TE couple legs, the effect of heat transfer between the TE couple leg and the ambient environment is not negligible. In this paper, based on basic theories of thermoelectric power generation and thermal science, detailed modeling of a thermoelectric generator taking account of the phenomenon of energy loss from the TE couple leg is reported. The revised generalized thermoelectric energy balance equations considering the effect of heat transfer between the TE couple leg and the ambient environment have been derived. Furthermore, characteristics of a multi-element thermoelectric generator with irreversibility have been investigated on the basis of the new derived TE equations. In the present investigation, second-law-based thermodynamic analysis (exergy analysis) has been applied to the irreversible heat transfer process in particular. It is found that the existence of the irreversible heat convection process causes a large loss of heat exergy in the TEG system, and using thermoelectric generators for low-grade waste heat recovery has promising potential. The results of irreversibility analysis, especially irreversible effects on generator system performance, based on the system model established in detail have guiding significance for

  11. Investigation of pressure transients in nuclear filtration systems: construction details of a large shock tube

    International Nuclear Information System (INIS)

    Smith, P.R.; Gregory, W.S.

    1980-04-01

    This report documents the construction of a 0.914-m (36-in.)-dia. shock tube on the New Mexico State University caompus. Highly variable low-grade explosions can be simulated with the shock tube. We plan to investigate the response of nuclear facility ventilation system components to low-grade explosions. Components of particular interest are high-capacity, high efficiency paticulate air (HEPA) filters. Shock tube construction details, operating principles, firing sequence, and preliminary results are reported

  12. 46 CFR 181.400 - Where required.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Where required. 181.400 Section 181.400 Shipping COAST... PROTECTION EQUIPMENT Fixed Fire Extinguishing and Detecting Systems § 181.400 Where required. (a) The... cubic meters (6,000 cubic feet); (2) A pre-engineered fixed gas fire extinguishing system must be in...

  13. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... An algorithm to retrieve Land Surface Temperature using Landsat-8 Dataset Abstract PDF. ISSN: 2225-8531.

  14. THE MEMORY SYSTEM ENGAGED DURING ACQUISITION DETERMINES THE EFFECTIVENESS OF DIFFERENT EXTINCTION PROTOCOLS

    Directory of Open Access Journals (Sweden)

    Jarid eGoodman

    2015-11-01

    Full Text Available Previous research indicates that extinction of rodent maze behavior may occur without explicit performance of the previously required response. In latent extinction, confining an animal to a previously rewarded goal location without reinforcement is typically sufficient to produce extinction of maze learning. However, previous studies have not determined whether latent extinction may be successfully employed to extinguish all types of memory acquired in the maze, or whether only specific types of memory may be vulnerable to latent extinction. The present study examined whether latent extinction may be effective across two plus-maze tasks that depend on anatomically distinct neural systems. Adult male Long-Evans rats were trained in a hippocampus-dependent place learning task (experiment 1, in which animals were trained to approach a consistent spatial location for food reward. A separate group of rats were trained in a dorsolateral striatum-dependent response learning task (experiment 2, in which animals were trained to make a consistent egocentric body-turn response for food reward. Following training, animals received response extinction or latent extinction. For response extinction, animals were given the opportunity to execute the original running approach response toward the empty food cup. For latent extinction, animals were confined to the original goal locations with the empty food cup, thus preventing them from making the original running approach response. Results indicate that, relative to no extinction, latent extinction was effective at extinguishing memory in the place learning task, but remained ineffective in the response learning task. In contrast, typical response extinction remained very effective at extinguishing memory in both place and response learning tasks. The present findings confirm that extinction of maze learning may occur with or without overt performance of the previously acquired response, but that the

  15. Main: Clone Detail [KOME

    Lifescience Database Archive (English)

    Full Text Available Clone Detail Mapping Pseudomolecule data detail Detail information Mapping to the T...IGR japonica Pseudomolecules kome_mapping_pseudomolecule_data_detail.zip kome_mapping_pseudomolecule_data_detail ...

  16. Author Details

    African Journals Online (AJOL)

    PROMOTING ACCESS TO AFRICAN RESEARCH. AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES. Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads.

  17. Author Details

    African Journals Online (AJOL)

    An Overview of Africa's Marine Resources: Their Utilization and Sustainable Management Details · Vol 12, No 3 (2000) - Articles EDITORIAL Ganoderma Lucidum - Paramount among Medicinal Mushrooms. Details · Vol 15, No 3 (2003) - Articles Editorial: Africa's Mushrooms: A neglected bioresource whose time has come

  18. Clinical professional governance for detailed clinical models.

    Science.gov (United States)

    Goossen, William; Goossen-Baremans, Anneke

    2013-01-01

    This chapter describes the need for Detailed Clinical Models for contemporary Electronic Health Systems, data exchange and data reuse. It starts with an explanation of the components related to Detailed Clinical Models with a brief summary of knowledge representation, including terminologies representing clinic relevant "things" in the real world, and information models that abstract these in order to let computers process data about these things. Next, Detailed Clinical Models are defined and their purpose is described. It builds on existing developments around the world and accumulates in current work to create a technical specification at the level of the International Standards Organization. The core components of properly expressed Detailed Clinical Models are illustrated, including clinical knowledge and context, data element specification, code bindings to terminologies and meta-information about authors, versioning among others. Detailed Clinical Models to date are heavily based on user requirements and specify the conceptual and logical levels of modelling. It is not precise enough for specific implementations, which requires an additional step. However, this allows Detailed Clinical Models to serve as specifications for many different kinds of implementations. Examples of Detailed Clinical Models are presented both in text and in Unified Modelling Language. Detailed Clinical Models can be positioned in health information architectures, where they serve at the most detailed granular level. The chapter ends with examples of projects that create and deploy Detailed Clinical Models. All have in common that they can often reuse materials from earlier projects, and that strict governance of these models is essential to use them safely in health care information and communication technology. Clinical validation is one point of such governance, and model testing another. The Plan Do Check Act cycle can be applied for governance of Detailed Clinical Models

  19. Author Details

    African Journals Online (AJOL)

    Petrology of the Cenomanian Upper Member of the Mamfe Embayment, southwestern Cameroon Details · Vol 38, No 1 (2002) - Articles Sequence stratigraphy of Iso field, western onshore Niger Delta, Nigeria Details · Vol 39, No 2 (2003) - Articles Preliminary studies on the lithostratigraphy and depositional environment of ...

  20. Challenges to fire protection measures at Hamaoka Nuclear Power Station

    International Nuclear Information System (INIS)

    Narama, Takeshi

    2015-01-01

    New regulatory standards for fire protection at nuclear power plants have been established by the Nuclear Regulation Authority. This paper introduces the measures taken by the Hamaoka Nuclear Power Station for the following four items, which were especially big changes. (1) To install a combination of sensors of different types or instruments with equivalent functions so as to be able to emit unique signals to inform a fire in the early stage. (2) To conduct 'UL vertical burn test' as the demonstration test for self-extinguishing performance as the condition for flame-retardant cable. (3) To install automatic fire-extinguishers or fixed fire-extinguishing devices of manual type at the spots where fire-fighting is difficult due to the filling of smoke in a fire or the effect of radiation. (4) To separate the system for purpose of ensuring safety function to attain the high-temperature shutdown and cold-temperature shutdown of a reactor whatever fire may happen at the nuclear facilities. The examples of the installation of fire-extinguishers as the measures for the above Item (3) are as follows; (A) as for the devices containing oil, a foam-extinguishing agent is released against each target device from the nozzle, and (B) for large vertical pump motors indoors and relatively small pump motors, IA type automatic foam extinguishing systems are installed. (A.O.)

  1. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Singh, J. Vol 3, No 2 (2011) - Articles Plane waves in a rotating generalized thermo-elastic solid with voids. Abstract PDF. ISSN: 2141-2839. AJOL African Journals Online. HOW TO USE AJOL.

  2. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Vol 12 (2008) - Articles On the wave equations of shallow water with rough bottom topography. Abstract · Vol 14 (2009) - Articles Energy generation in a plant due to variable sunlight intensity

  3. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Vol 45 (2016) - Articles From vectors to waves and streams: An alternative approach to semantic maps1. Abstract PDF · Vol 48 (2017) - Articles Introduction: 'n Klein ietsie for Johan Oosthuizen

  4. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... to blast loadings. Abstract PDF · Vol 9, No 3S (2017): Special Issue - Articles Experimental and numerical investigation on blast wave propagation in soil structure. Abstract PDF. ISSN: 1112-9867.

  5. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Iliopsoas haematoma in a rugby player. Abstract PDF · Vol 29, No 1 (2017) - Articles The use of negative pressure wave treatment in athlete recovery. Abstract PDF. ISSN: 2078-516X. AJOL African ...

  6. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... No 3S (2017): Special Issue - Articles Experimental and numerical investigation on blast wave propagation in soil structure. Abstract PDF · Vol 9, No 3S (2017): Special Issue - Articles Simulation on ...

  7. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Duwa, S S. Vol 8 (2004) - Articles Lower hybrid waves instability in a velocity–sheared inhomogenous charged dust beam. Abstract · Vol 9 (2005) - Articles The slide away theory of lower hybrid bursts

  8. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... The use of negative pressure wave treatment in athlete recovery. Abstract PDF · Vol 29, No 1 (2017) - Articles The prevalence, risk factors predicting injury and the severity of injuries sustained during ...

  9. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Vol 29, No 1 (2017) - Articles The use of negative pressure wave treatment in athlete recovery. Abstract PDF · Vol 29, No 1 (2017) - Articles The prevalence, risk factors predicting injury and the ...

  10. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Isa, M.F.M.. Vol 9, No 3S (2017): Special Issue - Articles Experimental and numerical investigation on blast wave propagation in soil structure. Abstract PDF · Vol 9, No 3S (2017): Special Issue - ...

  11. 76 FR 10476 - Special Conditions: Boeing Model 787-8 Airplane; Overhead Crew-Rest Compartment

    Science.gov (United States)

    2011-02-25

    ... should be used in determining placement of required fire extinguishers and protective breathing equipment... blockage, which might result from fire, mechanical or structural failure, or persons standing below or... ventilation rate. The system must have sufficient extinguishing agent to provide an initial knockdown and...

  12. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Abstract PDF · Vol 3, No 6 (2011) - Articles Mixed convection flow and heat transfer in a vertical wavy channel containing porous and fluid layer with traveling thermal waves. Abstract PDF · Vol 3, No 8 ...

  13. Author Details

    African Journals Online (AJOL)

    Author Details. Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Ismail, A. Vol 9, No 3S (2017): Special Issue - Articles Investigate of wave absorption performance for oil palm frond and empty fruit bunch at 5.8 GHz. Abstract PDF · Vol 9, No 3S (2017): Special Issue ...

  14. Space shuttle/food system study. Volume 2, Appendix G: Ground support system analysis. Appendix H: Galley functional details analysis

    Science.gov (United States)

    1974-01-01

    The capabilities for preflight feeding of flight personnel and the supply and control of the space shuttle flight food system were investigated to determine ground support requirements; and the functional details of an onboard food system galley are shown in photographic mockups. The elements which were identified as necessary to the efficient accomplishment of ground support functions include the following: (1) administration; (2) dietetics; (3) analytical laboratories; (4) flight food warehouse; (5) stowage module assembly area; (6) launch site module storage area; (7) alert crew restaurant and disperse crew galleys; (8) ground food warehouse; (9) manufacturing facilities; (10) transport; and (11) computer support. Each element is discussed according to the design criteria of minimum cost, maximum flexibility, reliability, and efficiency consistent with space shuttle requirements. The galley mockup overview illustrates the initial operation configuration, food stowage locations, meal assembly and serving trays, meal preparation configuration, serving, trash management, and the logistics of handling and cleanup equipment.

  15. Survey and Down-Selection of Acid Gas Removal Systems for the Thermochemical Conversion of Biomass to Ethanol with a Detailed Analysis of an MDEA System

    Energy Technology Data Exchange (ETDEWEB)

    Nexant, Inc., San Francisco, California

    2011-05-01

    The first section (Task 1) of this report by Nexant includes a survey and screening of various acid gas removal processes in order to evaluate their capability to meet the specific design requirements for thermochemical ethanol synthesis in NREL's thermochemical ethanol design report (Phillips et al. 2007, NREL/TP-510-41168). MDEA and selexol were short-listed as the most promising acid-gas removal agents based on work described in Task 1. The second report section (Task 2) describes a detailed design of an MDEA (methyl diethanol amine) based acid gas removal system for removing CO2 and H2S from biomass-derived syngas. Only MDEA was chosen for detailed study because of the available resources.

  16. 78 FR 26715 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Science.gov (United States)

    2013-05-08

    ... injection tubes during an engine fire, which could result in impaired distribution of the fire extinguishing... system injection tubes. This proposed AD is prompted by a report that the injection tubes are deforming... injection tubes during a fire, which could result in impaired distribution of the fire extinguishing agent...

  17. 46 CFR 167.45-30 - Use of approved fire-fighting equipment.

    Science.gov (United States)

    2010-10-01

    ... PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-30 Use of approved fire-fighting equipment. Portable fire extinguishers or fire-extinguishing systems which conform... 46 Shipping 7 2010-10-01 2010-10-01 false Use of approved fire-fighting equipment. 167.45-30...

  18. Detailed description of a state system for accounting for and control of nuclear material at the state level

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-02-01

    The purpose of this document is to provide a detailed description of the technical elements of a system for the accounting for and control of nuclear material at the State Authority level which can be used by a state in the establishment of a national system for nuclear material accounting and control. It is expected that a state system designed along the lines described also will assist the IAEA in carrying out its safeguards responsibilities. The scope of this document is limited to descriptions of the technical elements of a state level system concerned with Laws and Regulations, the Information System, and the Establishment of Requirements for Nuclear Material Accounting and Control. The discussion shows the relationship of these technical elements at the state level to the principal elements of an SSAC at the facility levels

  19. Contribution to a Theory of Detailed Design

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik

    1999-01-01

    It has been recognised, that literature actually do not propose a theory of detailed design. In this paper a theory contribution is proposed, linking part design to organ design and allowing a type of functional reasoning. The proposed theory satisfies our need for explaining the nature of a part...... structure, for support of synthesis of part structure, i.e. detailed design, and our need for digital modelling of part structures.The aim of this paper is to contribute to a design theory valid for detailed design. The proposal is based upon the theory's ability to explain the nature of machine parts...... and assemblies, to support the synthesis of parts and to allow the modelling, especially digital modelling of a part structure. The contribution is based upon Theory of Technical Systems, Hubka, and the Domain Theory, Andreasen. This paper is based on a paper presented at ICED 99, Mortensen, but focus...

  20. Online mass storage system detailed requirements document

    Science.gov (United States)

    1976-01-01

    The requirements for an online high density magnetic tape data storage system that can be implemented in a multipurpose, multihost environment is set forth. The objective of the mass storage system is to provide a facility for the compact storage of large quantities of data and to make this data accessible to computer systems with minimum operator handling. The results of a market survey and analysis of candidate vendor who presently market high density tape data storage systems are included.

  1. 49 CFR 176.900 - Packaging and stowage of cotton and vegetable fibers; general.

    Science.gov (United States)

    2010-10-01

    ... loading, the extinguishing system must be examined to ensure that it is in good working condition; and (7... extinguishers may be the vessel's equipment or shore equipment. (h) Smoking is not permitted on a vessel during... designated by the master. “NO SMOKING” signs must be conspicuously posted in appropriate places, and the...

  2. 46 CFR 95.50-10 - Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location. 95.50-10 Section 95.50-10 Shipping COAST GUARD...-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in accordance with Table 95.50-10(a). The location of the equipment shall be to...

  3. CMHC [Canada Mortgage and Housing Corporation] research project: Testing of air barrier construction details 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-03-31

    Air leakage control through the building envelope of wood framed houses is more important than ever. This is because owners expect better temperature control, higher indoor humidity in winter, low energy consumption and building durability. The leakage of air is controlled by the air barrier system. There are several new technologies to construct an air barrier system for the building envelope. These are the Poly Approach, the Air Drywall Approach (ADA) and the EASE system. The development of these systems was undertaken primarily by the building community without significant research and development. While it is believed that these methods improve airtightness it is not known if the improvement is marginal or significant. A study was conducted to determine actual performace of several different types of construction details for each of the different approaches. Each of these details was designed and constructed using one of the air barrier methods and tested in the laboratory. The test details included sill plate, the partition wall, the stair stringer, the electrical outlets, the bathtub detail, the plumbing stack detail, the metal chimney detail, the bathroom fan detail and the EASE wall system. The test results revealed that the Poly, ADA and EASE approaches reduce air leakage by a factor of six, if applied with a modest degree of workmanship. Further, certain Poly details are to be reconsidered because they lack adequate support against design wind load pressures. 37 figs., 12 tabs.

  4. Detail Enhancement for Infrared Images Based on Propagated Image Filter

    Directory of Open Access Journals (Sweden)

    Yishu Peng

    2016-01-01

    Full Text Available For displaying high-dynamic-range images acquired by thermal camera systems, 14-bit raw infrared data should map into 8-bit gray values. This paper presents a new method for detail enhancement of infrared images to display the image with a relatively satisfied contrast and brightness, rich detail information, and no artifacts caused by the image processing. We first adopt a propagated image filter to smooth the input image and separate the image into the base layer and the detail layer. Then, we refine the base layer by using modified histogram projection for compressing. Meanwhile, the adaptive weights derived from the layer decomposition processing are used as the strict gain control for the detail layer. The final display result is obtained by recombining the two modified layers. Experimental results on both cooled and uncooled infrared data verify that the proposed method outperforms the method based on log-power histogram modification and bilateral filter-based detail enhancement in both detail enhancement and visual effect.

  5. Modeling and Analysis of Realistic Fire Scenarios in Spacecraft

    Science.gov (United States)

    Brooker, J. E.; Dietrich, D. L.; Gokoglu, S. A.; Urban, D. L.; Ruff, G. A.

    2015-01-01

    An accidental fire inside a spacecraft is an unlikely, but very real emergency situation that can easily have dire consequences. While much has been learned over the past 25+ years of dedicated research on flame behavior in microgravity, a quantitative understanding of the initiation, spread, detection and extinguishment of a realistic fire aboard a spacecraft is lacking. Virtually all combustion experiments in microgravity have been small-scale, by necessity (hardware limitations in ground-based facilities and safety concerns in space-based facilities). Large-scale, realistic fire experiments are unlikely for the foreseeable future (unlike in terrestrial situations). Therefore, NASA will have to rely on scale modeling, extrapolation of small-scale experiments and detailed numerical modeling to provide the data necessary for vehicle and safety system design. This paper presents the results of parallel efforts to better model the initiation, spread, detection and extinguishment of fires aboard spacecraft. The first is a detailed numerical model using the freely available Fire Dynamics Simulator (FDS). FDS is a CFD code that numerically solves a large eddy simulation form of the Navier-Stokes equations. FDS provides a detailed treatment of the smoke and energy transport from a fire. The simulations provide a wealth of information, but are computationally intensive and not suitable for parametric studies where the detailed treatment of the mass and energy transport are unnecessary. The second path extends a model previously documented at ICES meetings that attempted to predict maximum survivable fires aboard space-craft. This one-dimensional model implies the heat and mass transfer as well as toxic species production from a fire. These simplifications result in a code that is faster and more suitable for parametric studies (having already been used to help in the hatch design of the Multi-Purpose Crew Vehicle, MPCV).

  6. Preliminary environmental assessment for the Satellite Power System (SPS). Revision 1. Volume 2. Detailed assessment

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The Department of Energy (DOE) is considering several options for generating electrical power to meet future energy needs. The satellite power system (SPS), one of these options, would collect solar energy through a system of satellites in space and transfer this energy to earth. A reference system has been described that would convert the energy to microwaves and transmit the microwave energy via directive antennas to large receiving/rectifying antennas (rectennas) located on the earth. At the rectennas, the microwave energy would be converted into electricity. The potential environmental impacts of constructing and operating the satellite power system are being assessed as a part of the Department of Energy's SPS Concept Development and Evaluation Program. This report is Revision I of the Preliminary Environmental Assessment for the Satellite Power System published in October 1978. It refines and extends the 1978 assessment and provides a basis for a 1980 revision that will guide and support DOE recommendations regarding future SPS development. This is Volume 2 of two volumes. It contains the technical detail suitable for peer review and integrates information appearing in documents referenced herein. The key environmental issues associated with the SPS concern human health and safety, ecosystems, climate, and electromagnetic systems interactions. In order to address these issues in an organized manner, five tasks are reported: (I) microwave-radiation health and ecological effects; (II) nonmicrowave health and ecological effectss; (III) atmospheric effects; (IV) effects on communication systems due to ionospheric disturbance; and (V) electromagnetic compatibility. (WHK)

  7. Emergency reactor cooling device

    International Nuclear Information System (INIS)

    Arakawa, Ken.

    1993-01-01

    An emergency nuclear reactor cooling device comprises a water reservoir, emergency core cooling water pipelines having one end connected to a water feeding sparger, fire extinguishing facility pipelines, cooling water pressurizing pumps, a diesel driving machine for driving the pumps and a battery. In a water reservoir, cooling water is stored by an amount required for cooling the reactor upon emergency and for fire extinguishing, and fire extinguishing facility pipelines connecting the water reservoir and the fire extinguishing facility are in communication with the emergency core cooling water pipelines connected to the water feeding sparger by system connection pipelines. Pumps are operated by a diesel power generator to introduce cooling water from the reservoir to the emergency core cooling water pipelines. Then, even in a case where AC electric power source is entirely lost and the emergency core cooling system can not be used, the diesel driving machine is operated using an exclusive battery, thereby enabling to inject cooling water from the water reservoir to a reactor pressure vessel and a reactor container by the diesel drive pump. (N.H.)

  8. (How) does sectoral detail affect the robustness of policy insights from energy system models? The refining sector's example

    International Nuclear Information System (INIS)

    Nicolas, Claire; Saint-Antonin, Valerie; Tchung-Ming, Stephane

    2014-01-01

    In this research, we rekindle an old debate by questioning the impact on mitigating policy evaluation of detailing a sub-sector in a global energy-transportation model. We chose the refining sector because it is a relevant case of a sector for which representation widely differs across models and because it offers a unique set of complex joint production in the energy sector. To investigate whether the level of detail in the description of the refinery impacts optimal mitigation options, we take the example of a long-term, national, linear programming based, energy-transport system model (TIMES based). We found that the refinery description used in the energy system model matters when trying to evaluate energy or climate policy applied to the transportation sector. It impacts the policy costs but also the technology trajectories chosen at the optimum. Essentially, the balance between energy efficiency and carbon intensity of transport may be affected by the accuracy of the description of the pivotal refining sector. Consequently, increasing this sector accuracy level should not only be motivated by the wish to gain wider quantitative insights on potential evolution of the energy system but also by the wish to improve the robustness of the model outcomes. (authors)

  9. COUNTERMEASURE FOR MINIMIZE UNWANTED ALARM OF AUTOMATIC FIRE NOTIFICATION SYSTEM IN THE REPUBLIC OF KOREA

    Directory of Open Access Journals (Sweden)

    Hasung Kong

    2015-01-01

    Full Text Available In this article investigated the cause of error through survey to building officials for minimizing the unwanted alarm of automatic fire notification and suggested countermeasure for minimizing the unwanted alarm. The main cause of the unwanted alarm is defective fire detector, interlocking with automatic fire detection system, lack in fire safety warden’s ability, worn-out fire detect receiving system. The countermeasure for minimizing unwanted alarm is firstly, tightening up the standard of model approval, Secondly, interlocking with cross-section circuit method fire extinguishing system or realizing automatic fire notification system interlocking with home network, thirdly, tightening up licensing examination of fire safety warden, lastly, it suggested term of use rule of fire detect receiving system.

  10. Improving antibiotic prescribing for adults with community acquired pneumonia: Does a computerised decision support system achieve more than academic detailing alone? – a time series analysis

    Directory of Open Access Journals (Sweden)

    Black James F

    2008-07-01

    Full Text Available Abstract Background The ideal method to encourage uptake of clinical guidelines in hospitals is not known. Several strategies have been suggested. This study evaluates the impact of academic detailing and a computerised decision support system (CDSS on clinicians' prescribing behaviour for patients with community acquired pneumonia (CAP. Methods The management of all patients presenting to the emergency department over three successive time periods was evaluated; the baseline, academic detailing and CDSS periods. The rate of empiric antibiotic prescribing that was concordant with recommendations was studied over time comparing pre and post periods and using an interrupted time series analysis. Results The odds ratio for concordant therapy in the academic detailing period, after adjustment for age, illness severity and suspicion of aspiration, compared with the baseline period was OR = 2.79 [1.88, 4.14], p Conclusion Deployment of a computerised decision support system was associated with an early improvement in antibiotic prescribing practices which was greater than the changes seen with academic detailing. The sustainability of this intervention requires further evaluation.

  11. On Detailing in Contemporary Architecture

    DEFF Research Database (Denmark)

    Kristensen, Claus; Kirkegaard, Poul Henning

    2010-01-01

    Details in architecture have a significant influence on how architecture is experienced. One can touch the materials and analyse the detailing - thus details give valuable information about the architectural scheme as a whole. The absence of perceptual stimulation like details and materiality...... / tactility can blur the meaning of the architecture and turn it into an empty statement. The present paper will outline detailing in contemporary architecture and discuss the issue with respect to architectural quality. Architectural cases considered as sublime piece of architecture will be presented...

  12. Detailed Electrochemical Characterisation of Large SOFC Stacks

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2012-01-01

    application of advanced methods for detailed electrochemical characterisation during operation. An operating stack is subject to steep compositional gradients in the gaseous reactant streams, and significant temperature gradients across each cell and across the stack, which makes it a complex system...... Fuel Cell A/S was characterised in detail using electrochemical impedance spectroscopy. An investigation of the optimal geometrical placement of the current probes and voltage probes was carried out in order to minimise measurement errors caused by stray impedances. Unwanted stray impedances...... are particularly problematic at high frequencies. Stray impedances may be caused by mutual inductance and stray capacitance in the geometrical set-up and do not describe the fuel cell. Three different stack geometries were investigated by electrochemical impedance spectroscopy. Impedance measurements were carried...

  13. Electrochemical performance evaluations and safety investigations of pentafluoro(phenoxy)cyclotriphosphazene as a flame retardant electrolyte additive for application in lithium ion battery systems using a newly designed apparatus for improved self-extinguishing time measurements

    Science.gov (United States)

    Dagger, Tim; Lürenbaum, Constantin; Schappacher, Falko M.; Winter, Martin

    2017-02-01

    A modified self-extinguishing time (SET) device which enhances the reproducibility of the results is presented. Pentafluoro(phenoxy)cyclotriphosphazene (FPPN) is investigated as flame retardant electrolyte additive for lithium ion batteries (LIBs) in terms of thermal stability and electrochemical performance. SET measurements and adiabatic reaction calorimetry are applied to determine the flammability and the reactivity of a standard LIB electrolyte containing 5% FPPN. The results reveal that the additive-containing electrolyte is nonflammable for 10 s whereas the commercially available reference electrolyte inflames instantaneously after 1 s of ignition. The onset temperature of the safety enhanced electrolyte is delayed by ≈ 21 °C. Compatibility tests in half cells show that the electrolyte is reductively stable while the cyclic voltammogram indicates oxidative decomposition during the first cycle. Cycling experiments in full cells show improved cycling performance and rate capability, which can be attributed to cathode passivation during the first cycle. Post-mortem analysis of the electrolyte by gas chromatography-mass spectrometry confirms the presence of the additive in high amounts after 501 cycles which ensures enhanced safety of the electrolyte. The investigations present FPPN as stable electrolyte additive that improves the intrinsic safety of the electrolyte and its cycling performance at the same time.

  14. 14 CFR 27.685 - Control system details.

    Science.gov (United States)

    2010-01-01

    ... must be means to prevent the slapping of cables or tubes against other parts. (d) Cable systems must be designed as follows: (1) Cables, cable fittings, turnbuckles, splices, and pulleys must be of an acceptable kind. (2) The design of the cable systems must prevent any hazardous change in cable tension throughout...

  15. 14 CFR 29.685 - Control system details.

    Science.gov (United States)

    2010-01-01

    ... must be means to prevent the slapping of cables or tubes against other parts. (d) Cable systems must be designed as follows: (1) Cables, cable fittings, turnbuckles, splices, and pulleys must be of an acceptable kind. (2) The design of cable systems must prevent any hazardous change in cable tension throughout the...

  16. 46 CFR 193.50-5 - Classification.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...

  17. Contrast-detail analysis of three flat panel detectors for digital radiography

    International Nuclear Information System (INIS)

    Borasi, Giovanni; Samei, Ehsan; Bertolini, Marco; Nitrosi, Andrea; Tassoni, Davide

    2006-01-01

    In this paper we performed a contrast detail analysis of three commercially available flat panel detectors, two based on the indirect detection mechanism (GE Revolution XQ/i, system A, and Trixell/Philips Pixium 4600, system B) and one based on the direct detection mechanism (Hologic DirectRay DR 1000, system C). The experiment was conducted using standard x-ray radiation quality and a widely used contrast-detail phantom. Images were evaluated using a four alternative forced choice paradigm on a diagnostic-quality softcopy monitor. At the low and intermediate exposures, systems A and B gave equivalent performances. At the high dose levels, system A performed better than system B in the entire range of target sizes, even though the pixel size of system A was about 40% larger than that of system B. At all the dose levels, the performances of the system C (direct system) were lower than those of system A and B (indirect systems). Theoretical analyses based on the Perception Statistical Model gave similar predicted SNR T values corresponding to an observer efficiency of about 0.08 for systems A and B and 0.05 for system C

  18. Generalized detailed balance theory of solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Kirchartz, Thomas

    2009-12-12

    The principle of detailed balance is the requirement that every microscopic process in a system must be in equilibrium with its inverse process, when the system itself is in thermodynamic equilibrium. This detailed balance principle has been of special importance for photovoltaics, since it allows the calculation of the limiting efficiency of a given solar cell by defining the only fundamental loss process as the radiative recombination of electron/hole pairs followed by the emission of a photon. In equilibrium, i.e. in the dark and without applied voltage, the absorbed and emitted photon flux must be equal due to detailed balance. This equality determines the radiative recombination from absorption and vice versa. While the classical theory of photovoltaic efficiency limits by Shockley and Queisser considers only one detailed balance pair, namely photogeneration and radiative recombination, the present work extends the detailed balance principle to any given process in the solar cell. Applying the detailed balance principle to the whole device leads to two major results, namely (i) a model that is compatible with the Shockley-Queisser efficiency limit for efficient particle transport, while still being able to describe non-ideal and non-linear solar cells, and (ii) an analytical relation between electroluminescent emission and photovoltaic action of a diode that is applied to a variety of different solar cells. This thesis presents several variations of a detailed balance model that are applicable to different types of solar cells. Any typical inorganic solar cell is a mainly bipolar device, meaning that the current is carried by electrons and holes. The detailed balance model for pn-type and pin-type bipolar solar cells is therefore the most basic incorporation of a detailed balance model. The only addition compared to the classical diode theory or compared to standard one-dimensional device simulators is the incorporation of photon recycling, making the model

  19. Sodium fire protection

    International Nuclear Information System (INIS)

    Raju, C.; Kale, R.D.

    1979-01-01

    Results of experiments carried out with sodium fires to develop extinguishment techniques are presented. Characteristics, ignition temperature, heat evolution and other aspects of sodium fires are described. Out of the powders tested for extinguishment of 10 Kg sodium fires, sodium bi-carbonate based dry chemical powder has been found to be the best extinguisher followed by large sized vermiculite and then calcium carbonate powders distributed by spray nozzles. Powders, however, do not extinguish large fires effectively due to sodium-concrete reaction. To control large scale fires in a LMFBR, collection trays with protective cover have been found to cause oxygen starvation better than flooding with inert gas. This system has an added advantage in that there is no damage to the sodium facilities as has been in the case of powders which often contain chlorine compounds and cause stress corrosion cracking. (M.G.B.)

  20. Bolivia-Brazil gas line route detailed

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that state oil companies of Brazil and Bolivia have signed an agreement outlining the route for a 2,270 km pipeline system to deliver natural gas from Bolivian fields to Southeast Brazil. The two sides currently are negotiating details about construction costs as well as contract volumes and prices. Capacity is projected at 283-565 MMcfd. No official details are available, but Roberto Y. Hukai, a director of the Sao Paulo engineering company Jaako Poyry/Technoplan, estimates transportation cost of the Bolivian gas at 90 cents/MMBTU. That would be competitive with the price of gas delivered to the Sao Paulo gas utility Comgas, he the. Brazil's Petroleos Brasileiro SA estimates construction of the pipeline on the Brazilian side alone with cost $1.2-1.4 billion. Bolivia's Yacimientos Petroliferos Fiscales Bolivianos (YPFB) is negotiating with private domestic and foreign investors for construction of the Bolivian portion of the project

  1. Automatic generation of medium-detailed 3D models of buildings based on CAD data

    NARCIS (Netherlands)

    Dominguez-Martin, B.; Van Oosterom, P.; Feito-Higueruela, F.R.; Garcia-Fernandez, A.L.; Ogayar-Anguita, C.J.

    2015-01-01

    We present the preliminary results of a work in progress which aims to obtain a software system able to automatically generate a set of diverse 3D building models with a medium level of detail, that is, more detailed that a mere parallelepiped, but not as detailed as a complete geometric

  2. GEOMETRIC MODELLING OF TREE ROOTS WITH DIFFERENT LEVELS OF DETAIL

    Directory of Open Access Journals (Sweden)

    J. I. Guerrero Iñiguez

    2017-09-01

    Full Text Available This paper presents a geometric approach for modelling tree roots with different Levels of Detail, suitable for analysis of the tree anchoring, potentially occupied underground space, interaction with urban elements and damage produced and taken in the built-in environment. Three types of tree roots are considered to cover several species: tap root, heart shaped root and lateral roots. Shrubs and smaller plants are not considered, however, a similar approach can be considered if the information is available for individual species. The geometrical approach considers the difficulties of modelling the actual roots, which are dynamic and almost opaque to direct observation, proposing generalized versions. For each type of root, different geometric models are considered to capture the overall shape of the root, a simplified block model, and a planar or surface projected version. Lower detail versions are considered as compatibility version for 2D systems while higher detail models are suitable for 3D analysis and visualization. The proposed levels of detail are matched with CityGML Levels of Detail, enabling both analysis and aesthetic views for urban modelling.

  3. Geometric Modelling of Tree Roots with Different Levels of Detail

    Science.gov (United States)

    Guerrero Iñiguez, J. I.

    2017-09-01

    This paper presents a geometric approach for modelling tree roots with different Levels of Detail, suitable for analysis of the tree anchoring, potentially occupied underground space, interaction with urban elements and damage produced and taken in the built-in environment. Three types of tree roots are considered to cover several species: tap root, heart shaped root and lateral roots. Shrubs and smaller plants are not considered, however, a similar approach can be considered if the information is available for individual species. The geometrical approach considers the difficulties of modelling the actual roots, which are dynamic and almost opaque to direct observation, proposing generalized versions. For each type of root, different geometric models are considered to capture the overall shape of the root, a simplified block model, and a planar or surface projected version. Lower detail versions are considered as compatibility version for 2D systems while higher detail models are suitable for 3D analysis and visualization. The proposed levels of detail are matched with CityGML Levels of Detail, enabling both analysis and aesthetic views for urban modelling.

  4. Detailed Chemical Kinetic Modeling of Hydrazine Decomposition

    Science.gov (United States)

    Meagher, Nancy E.; Bates, Kami R.

    2000-01-01

    The purpose of this research project is to develop and validate a detailed chemical kinetic mechanism for gas-phase hydrazine decomposition. Hydrazine is used extensively in aerospace propulsion, and although liquid hydrazine is not considered detonable, many fuel handling systems create multiphase mixtures of fuels and fuel vapors during their operation. Therefore, a thorough knowledge of the decomposition chemistry of hydrazine under a variety of conditions can be of value in assessing potential operational hazards in hydrazine fuel systems. To gain such knowledge, a reasonable starting point is the development and validation of a detailed chemical kinetic mechanism for gas-phase hydrazine decomposition. A reasonably complete mechanism was published in 1996, however, many of the elementary steps included had outdated rate expressions and a thorough investigation of the behavior of the mechanism under a variety of conditions was not presented. The current work has included substantial revision of the previously published mechanism, along with a more extensive examination of the decomposition behavior of hydrazine. An attempt to validate the mechanism against the limited experimental data available has been made and was moderately successful. Further computational and experimental research into the chemistry of this fuel needs to be completed.

  5. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register ... (2013) - Articles Technical Note: Development of a Photobioreactor for Microalgae Culture ... Design, Construction and Evaluation of Motorized Okra Slicer Abstract PDF ...

  6. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to ... No 1 (2014) - Articles Knowledge and Attitudes towards Basic Cardiopulmonary Resuscitation (CPR) among Community Nurses in Remo Area of Ogun State, Nigeria

  7. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details ... Design and Implementation of an M/M/1 Queuing Model Algorithm and its Applicability in ... Vehicle Identification Technology to Intercept Small Arms and Ammunition on Nigeria Roads

  8. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or ... The prevention of mother-to-child HIV transmission programme and infant feeding practices ... Evaluation of a diagnostic algorithm for smear-negative pulmonary tuberculosis in ...

  9. COUNTERMEASURE FOR MINIMIZE UNWANTED ALARM OF AUTOMATIC FIRE NOTIFICATION SYSTEM IN THE REPUBLIC OF KOREA

    Directory of Open Access Journals (Sweden)

    Hasung Kong

    2015-01-01

    Full Text Available In this article investigated the cause of error through survey to building officials for minimizing the unwanted alarm of automatic fire notification and suggested countermeasure for minimizing the unwanted alarm. The main cause of the unwanted alarm is defective fire detector, interlocking with automatic fire detection system, lack in fire safety warden’s ability, worn-out fire detect receiving system. The countermeasure for minimizing unwanted alarm is firstly, tightening up the standard of model approval, Secondly, interlocking with cross-section circuit method fire extinguishing system or realizing automatic fire notification system interlocking with home network, thirdly, tightening up licensing examination of fire safety warden, lastly, it suggested term of use rule of fire detect receiving system

  10. Experience in the field of sodium fire and prevention in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Tsuzawa, Y [Power Reactor and Nuclear Fuel Development Corp., Akasaka, Minato-ku, Tokyo (Japan)

    1979-03-01

    The existing facilities of sodium technology development and liquid sodium cooled fast breeder reactors are equipped with fire-extinguishing powder capable of putting out fire by smothering in case of accidental sodium fire induced by the leakage of high temperature sodium from the circulating system. The purpose of this experiment is to obtain quantitatively the relationship between such a fire-extinguishing powder needed and sodium temperature and its depth. The fourteen different experiments were performed using Na{sub 2}CO{sub 3} type and NaCl type powder both of which are authorized as fire-extinguishing agent under the present governmental regulation, and the sodium (25 cm deep in the test container) being heated up to 300 deg. C and 600 deg. C, and burned. The present experiment has shown the prospective that the amount of fire extinguishing powder of 45 kg/m{sup 2} at maximum is sufficient to control the accidental sodium fire under the foreseeable circumstances. (author)

  11. Experience in the field of sodium fire and prevention in Japan

    International Nuclear Information System (INIS)

    Tsuzawa, Y.

    1979-01-01

    The existing facilities of sodium technology development and liquid sodium cooled fast breeder reactors are equipped with fire-extinguishing powder capable of putting out fire by smothering in case of accidental sodium fire induced by the leakage of high temperature sodium from the circulating system. The purpose of this experiment is to obtain quantitatively the relationship between such a fire-extinguishing powder needed and sodium temperature and its depth. The fourteen different experiments were performed using Na 2 CO 3 type and NaCl type powder both of which are authorized as fire-extinguishing agent under the present governmental regulation, and the sodium (25 cm deep in the test container) being heated up to 300 deg. C and 600 deg. C, and burned. The present experiment has shown the prospective that the amount of fire extinguishing powder of 45 kg/m 2 at maximum is sufficient to control the accidental sodium fire under the foreseeable circumstances. (author)

  12. Revisiting the Seductive Details Effect in Multimedia Learning: Context-Dependency of Seductive Details

    Science.gov (United States)

    Ozdemir, Devrim; Doolittle, Peter

    2015-01-01

    The purpose of this study was to investigate the effects of context-dependency of seductive details on recall and transfer in multimedia learning environments. Seductive details were interesting yet irrelevant sentences in the instructional text. Two experiments were conducted. The purpose of Experiment 1 was to identify context-dependent and…

  13. Active solar distillation - A detailed review

    Energy Technology Data Exchange (ETDEWEB)

    Sampathkumar, K.; Pitchandi, P. [Department of Mechanical Engineering, Tamilnadu College of Engineering, Coimbatore 641659, Tamilnadu (India); Arjunan, T.V. [Department of Automobile Engineering, PSG College of Technology, Coimbatore 641004, Tamilnadu (India); Senthilkumar, P. [Department of Mechanical Engineering, KSR College of Engineering, Tiruchengode 637215, Tamilnadu (India)

    2010-08-15

    All over the world, access to potable water to the people are narrowing down day by day. Most of the human diseases are due to polluted or non-purified water resources. Even today, under developed countries and developing countries face a huge water scarcity because of unplanned mechanism and pollution created by manmade activities. Water purification without affecting the ecosystem is the need of the hour. In this context, many conventional and non-conventional techniques have been developed for purification of saline water. Among these, solar distillation proves to be both economical and eco-friendly technique particularly in rural areas. Many active distillation systems have been developed to overcome the problem of lower distillate output in passive solar stills. This article provides a detailed review of different studies on active solar distillation system over the years. Thermal modelling was done for various types of active single slope solar distillation system. This review would also throw light on the scope for further research and recommendations in active solar distillation system. (author)

  14. Author Details

    African Journals Online (AJOL)

    Radwan M.D, Mona Ahmed. Vol 12, No 1 (2000) - Articles RELAPSING REMITTING MULTIPLE SCLEROSIS: CT AND MRI IMAGING VS CLINICAL FINDINGIN THE DIAGNOSIS AND DETERMINATION OF DISEASE ACTIVITY. Details. ISSN: 1110-5607. AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  15. In the Scientific and Technological Council of National Mining Technological Supervision of the USSR

    Energy Technology Data Exchange (ETDEWEB)

    Manevich, V G

    1981-04-01

    A report is presented from the conference of the Scientific Council on preventing and fighting underground fires in coal mines and other mines, improving rescue equipment, and production of rescue equipment. Papers on activities of the major scientific institutes of the country investigating problems associated with fire prevention and fire fighting as well as design of life support systems, rescue equipment and safety engineering are discussed. Several rescue systems and life support systems are reviewed: Poiski-1 analyzer, Iskra oxygen analyzer; ShS-7m, ShSM-1 and ShRC-2 respirators; PSP, PSPM, PSA, and Vozduch emergency air supply systems. Recommendations on research activities and production of rescue equipment in the coal mining industry are formulated: production of a complex system of fire fighting mine cars moving on tracks (using foam and fire extinguishing powder); installation of the Vikhr-1 fire extinguishing system on existing fire fighting cars (P-2AP powder); starting industrial production of RKGD valves useful in rock burst prevention and in preventing dust hazard; improving methods of extinguishing endogenous fires, starting production of Gorizont-M fire detecting system, designing efficient systems detecting miners lost during mine accidents (sudden roof falls, rock bursts, etc.). (In Russian)

  16. Author Details

    African Journals Online (AJOL)

    Green, J.M.. Vol 10, No 1 (2001) - Articles Information from Radio Telemetry on movements and exploitation of naturalized Rainbow trout, Oncorhynchus mykiss (Walbaum), in Kenya cold water streams. Details. ISSN: 0002-0036. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  17. Criticality and fire-fighting - Recent developments at Westinghouse, Springfields Fuels Limited

    International Nuclear Information System (INIS)

    Hill, D. A.; Clemson, P. D.

    2009-01-01

    Fire-fighting advice in criticality-controlled areas has traditionally presented unique challenges to the nuclear industry, primarily because of the introduction of moderators / reflectors from water and foam and the potential rearrangement of materials. In an actual emergency, the decision to use water-based fire extinguishing methods is best influenced by a consensus between the criticality and fire specialists as part of the emergency planning process. A recent review of the fire-fighting arrangements at the site operated by Springfields Fuels Limited (SFL) in Preston in the United Kingdom has identified that more detailed guidance may be valuable relating to the specific areas and materials at risk, particularly to highlight the degree of risk and provide guidance on the risk of criticality if water-based fire extinguishing methods were deemed necessary. This has prompted consideration of a criticality 'Fire Tag' system, consisting of colour coded markers in the area (an immediate visual indicator of both the degree of risk and the appropriate fire-fighting response) and single sheet cards (specific guidance for the areas and materials at risk), with the process supported by appropriate training. The approach is currently being trialled on a small scale, and initial feedback from personnel has been positive. (authors)

  18. Inexpensive system protects megawatt resistance-heating furnace against high-voltage surges

    Science.gov (United States)

    Stearns, E. J.

    1971-01-01

    Coolant gas extinguishes arcing across the break in a heater element. Air-gap shunt which bypasses high voltage impressed across the circuit prevents damage if the resistance elements break and open the inductive circuit.

  19. Sorption ability of the soil and its impact on environmental contamination

    OpenAIRE

    H?ibov?, ??rka; Gargo?ov?, Helena Zl?malov?; V?vrov?, Milada

    2015-01-01

    From the physical point of view, soil is a heterogenic polydisperse system. It often becomes a place of a secondary contamination during extinguishing uncontrolled areal fires in nature. Foam extinguishing agents (FEAs), used at these events, basically contain surface active substances and perfluorinated compounds. These tend to be captured in the soil matrix due to their specific properties. Contaminants could be partly flushed out with rainwater, which causes several times dilution of conta...

  20. Author Details

    African Journals Online (AJOL)

    Aderinokun, GA. Vol 9, No 1 (1999) - Articles Relative Influence Of Sociodemographic Variables On Oral Health And Habits Of Some Nigerian School Children Abstract · Vol 9, No 4 (1999) - Articles Oral health services in Nigeria Details. ISSN: 0189-2657. AJOL African Journals Online. HOW TO USE AJOL.

  1. Author Details

    African Journals Online (AJOL)

    Development of a trap to contaminate variegated grasshoppers (Zonocerus variegatus L.) (Orthoptera: Pyrgomorphidae) with Metarrhyzium flavo-viride Gams & Rozsypal in the field. Details · Vol 40, No 1 (2007) - Articles Yam pests in the Ashanti and Brong Ahafo regions of Ghana: A study of farmers\\' indigenous technical ...

  2. Author Details

    African Journals Online (AJOL)

    Geotechnical properties of lateritic soil developed over quartz schist in Ishara area, south western Nigeria Details · Vol 44, No 1 (2008) - Articles Comparative study of the influence of cement and lime stabilization on geotechnical properties of lateritic soil derived from pegmatite in Ago-Iwoye area, southwestern Nigeria

  3. Author Details

    African Journals Online (AJOL)

    SAMA, G. Vol 2 (2002): Supplement - Articles A Longitudinal Study of the Role of T Cell subset, Th1/Th2 cytokines and antiplasmodial antibodies in uncomplicated Malaria in a Village Population Chronically Exposed to Plasmodium falciparum Malaria. Details PDF · AJOL African Journals Online. HOW TO USE AJOL.

  4. Author Details

    African Journals Online (AJOL)

    KOUONTCHOU, Samuel. Vol 2 (2002): Supplement - Articles Prevalence of Multiple Concomitant Intestinal Parasitic Infections in Simbok a Malaria Endemic Village in Cameroon. Details PDF · Vol 2 (2002): Supplement - Articles A Longitudinal Study of the Role of T Cell subset, Th1/Th2 cytokines and antiplasmodial ...

  5. Author Details

    African Journals Online (AJOL)

    ALAKE, J. Vol 2 (2002): Supplement - Articles A Longitudinal Study of the Role of T Cell subset, Th1/Th2 cytokines and antiplasmodial antibodies in uncomplicated Malaria in a Village Population Chronically Exposed to Plasmodium falciparum Malaria. Details PDF · AJOL African Journals Online. HOW TO USE AJOL.

  6. Author Details

    African Journals Online (AJOL)

    A Preliminary Investigation of Relative Frequency of Undiagnosed and Previously Diagnosed Hypertension Before First Stroke in a Lagos Hospital Abstract · Vol 9, No 4 (1999) - Articles Localised tetanus in Lagos, Nigeria Details · Vol 9, No 4 (1999) - Articles Stroke with localised infarction of Wernicke's Area misdiagnosed ...

  7. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text ... Abstract · Vol 17 (2010) - Articles Investigating The Travelling Wave Solution For an SIR Endemic Disease Model With No Disease Related Death (When The Spatial Spread Of The Susceptible Is Not Negligible). Abstract.

  8. Author Details

    African Journals Online (AJOL)

    Rakotonirina, Alice. Vol 2, No 2 (2002) - Articles Effect of the decoction of rhizomes of Cyperus articulatus on bicuculline-, N-methyl-D-aspartate- and strychnine-induced behavioural excitation and convulsions in mice. Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  9. Adsorber fires

    International Nuclear Information System (INIS)

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  10. The devil is in the detail: children's recollection of details about their prior experiences.

    Science.gov (United States)

    Strange, Deryn; Hayne, Harlene

    2013-01-01

    Adults sometimes report highly specific details of childhood events, including the weather, what they or others were wearing, as well as information about what they or others said or were thinking at the time. When these details are reported in the course of research they shape our theories of memory development; when they are reported in a criminal trial they influence jurors' evaluation of guilt or innocence. The key question is whether these details were encoded at the time the event took place or have been added after the fact. We addressed this question prospectively by examining the memory accounts of children. In Experiment 1 we coded the reports of 5- to 6-year-olds and 9- to 10-year-olds who had experienced a unique event. We found that spontaneous mentions of these specific details were exceedingly rare. In Experiment 2 we questioned additional children about a similar event using specific questions to extract those details. We found that 9- to 10-year-olds were able to accurately answer, while 5- to 6-year-olds had considerable difficulty. Moreover, when the younger children did respond they provided generic, forensically inadequate, information. These data have important implications for the courtroom and for current theories of memory development and childhood amnesia.

  11. Author Details

    African Journals Online (AJOL)

    NENTY, N. JOHNSON. Vol 7, No 3 (2001) - Articles Common errors and perfomance of students in junior secondary mathematics certificate examinations in Cross River State, Nigeria Details PDF. ISSN: 1118-0579. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's ...

  12. Author Details

    African Journals Online (AJOL)

    QUAKYI, A.I.. Vol 2 (2002): Supplement - Articles A Longitudinal Study of the Role of T Cell subset, Th1/Th2 cytokines and antiplasmodial antibodies in uncomplicated Malaria in a Village Population Chronically Exposed to Plasmodium falciparum Malaria. Details PDF · AJOL African Journals Online. HOW TO USE AJOL.

  13. Author Details

    African Journals Online (AJOL)

    Admasu, Assefa. Vol 22, No 2 (1999) - Articles Preliminary evaluation of Phytomyza orobanchia (Diptera: Agromyzidae) as a controller of Orobanche spp in Ethiopia Details PDF. ISSN: 2520–7997. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL ...

  14. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Obtaining the green's function for electromagnetic waves propagating in layered in-homogeneous thin film media of spherical particles on a substrate. Abstract · Vol 20, No 2 (2008) - Articles solution growth and ...

  15. Author Details

    African Journals Online (AJOL)

    Lema, VM. Vol 80, No 9 (2003): - Articles Fournier's gangrene complicating vasectomy. Details PDF · Vol 86, No 6 (2009) - Articles Therapeutic misconception and clinical trials in sub-saharan Africa: A review. Abstract PDF · Vol 86, No 11 (2009) - Articles HIV/AIDS and pregnancy-related deaths in Blantyre, Malawi

  16. Author Details

    African Journals Online (AJOL)

    Motabagani, MA. Vol 80, No 9 (2003): - Articles Anomalies of the renal, phrenic and suprarenal arteries: Case Report Details PDF · Vol 81, No 3 (2004): - Articles Morphological study of the uncommon rectus sterni muscle in German cadavers. Abstract PDF. ISSN: 0012-835X. AJOL African Journals Online. HOW TO USE ...

  17. Author Details

    African Journals Online (AJOL)

    Ibeabuchi, NM. Vol 10, No 3 (2000) - Articles Comparison of the effects of Methylsalicylate Cream with cryotherapy on delayed onset muscle soreness. Details · Vol 22, No 2 (2012) - Articles X-ray Pelvimetry And Labour Outcome In Term Pregnancy In A Rural Nigerian Population Abstract. ISSN: 0189-2657. AJOL African ...

  18. Level 2 and level 2.5 large deviation functionals for systems with and without detailed balance

    International Nuclear Information System (INIS)

    Hoppenau, J; Nickelsen, D; Engel, A

    2016-01-01

    Large deviation functions are an essential tool in the statistics of rare events. Often they can be obtained by contraction from a so-called level 2 or level 2.5 large deviation functional characterizing the empirical density and current of the underlying stochastic process. For Langevin systems obeying detailed balance, the explicit form of the level 2 functional has been known ever since the mathematical work of Donsker and Varadhan. We rederive the Donsker–Varadhan result using stochastic path-integrals. We than generalize the derivation to level 2.5 large deviation functionals for non-equilibrium steady states and elucidate the relation between the large deviation functionals and different notions of entropy production in stochastic thermodynamics. Finally, we discuss some aspects of the contractions to level 1 large deviation functions and illustrate our findings with examples. (paper)

  19. Utilisation of a new fire fighting device on board of a diesel vehicle in the underground German black coal industry; Einsatz einer neuartigen bordfesten Loeschanlage auf dieselgetriebenen Fahrzeugen im untertaegigen deutschen Steinkohlenbergbau

    Energy Technology Data Exchange (ETDEWEB)

    Fetting, Dieter; Alze, Matthias [Bergwerk Ost, Hamm (Germany); Cerny, Udo [RAG Aktiengesellschaft, Herne (Germany). Servicebereich Technik und Logistik - DZGR

    2010-03-15

    In the German hard coal mining industry approximately since the 1970ies, automatically releasing stationary powder snow based fire fighting systems are built on diesel vehicles due to reasons of fire protection. These fire fighting systems are to recognize a developing fire by sensors and to extinguish the fire by an automatic output of a fire fighting agent with high rate (HRD = High Rate Discharge) into a closed engine compartment or within the range of hydraulics. Simultaneously with the releasing of the fire extinguishing system the engine of the vehicle is stop automatically. Due to the stationary fire fighting systems diesel vehicles are not classified with views of risk as fire load.

  20. Effects of Leptothrix discophora on the potential behavior of stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Carpen, L.; Hakkarainen, T. [VTT Industrial Systems, P.O. Box 1704, FIN-02044 VTT (Finland); Raaska, L.; Kujanpaeae, K. [VTT Biotechnology, P.O. Box 1500, FIN-02044 VTT (Finland)

    2003-07-01

    Biofilm formation and electrochemical behavior of stainless steel have been studied in well water, in tap water and in water taken from fire extinguishing system. Some of the waters have been modified by adding manganese ions as well as in some cases acetate and yeast extract as a nutrient. Manganese oxidizing bacteria Leptothrix discophora has been used in these studies. To eliminate crevices in the specimen holder and to simulate reasonably well the conditions in fire-extinguishing systems where the water is stagnant most of the time, a tape test arrangement with very slow flowing rate has been used in most of these studies. Also specimens with heat tint areas produced by heating inductively a small section of the specimen under flowing argon shielding gas were used in these studies. The results of these tape tests show that manganese oxidizing bacteria are able to increase the potential of both the base material (stainless steel UNS S30400) and of specimens with heat tint areas in well water, in tap water and in water taken from fire extinguishing system. Manganese oxidizing bacteria are also able to increase the cathodic reaction and thus enhance the initiation of corrosion. However, the increase of potential is not alone enough to start the corrosion. In these tests corrosion was initiated only in the specimens with heat tint areas in one of the waters taken from fire extinguishing system. No corrosion was detected in the specimens exposed to the well water or to the tap water used in these tests. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  1. Author Details

    African Journals Online (AJOL)

    Brown, Duncan. Vol 16, No 2 (2002): Continental Africans & the Question of Identity - Articles Environment and Identity: Douglas Livingstone's A Littoral Zone Details. ISSN: 0256-004. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  2. Author Details

    African Journals Online (AJOL)

    SONUGA, F A. Vol 6, No 1 (2000) - Articles Geophysical investigation of Karkarku earthdam embankment. Details. ISSN: 1118-0579. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL ...

  3. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Vol 8 (2004) - Articles Further on stokes expansions for the finite amplitude water waves. Abstract · Vol 11 (2007) - Articles On the effects of wave steepness on higher order Stokes waves. Abstract. ISSN: 1116-4336.

  4. Author Details

    African Journals Online (AJOL)

    Focho, DA. Vol 2, No 1 (2002) - Articles Observations on the Meiotic Process in the African Pest Grasshopper Taphronota thaelephora Stal. (Orthoptera : Pyrgomorphidae) Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  5. Monte Carlo methods beyond detailed balance

    NARCIS (Netherlands)

    Schram, Raoul D.; Barkema, Gerard T.|info:eu-repo/dai/nl/101275080

    2015-01-01

    Monte Carlo algorithms are nearly always based on the concept of detailed balance and ergodicity. In this paper we focus on algorithms that do not satisfy detailed balance. We introduce a general method for designing non-detailed balance algorithms, starting from a conventional algorithm satisfying

  6. Corrosion of fire extinguishing systems and fire fighting fittings

    OpenAIRE

    RAKOWSKA JOANNA; ŚLOSORZ ZUZANNA

    2011-01-01

    Устройства пожаротушения должны характеризоваться высокой эффективностью и надёжностью. Одним из вопросов, связанных с надёжностью таких устройств, является задержка развития коррозии благодаря правильному выбору материалов, из которых изготавливаются детали или применение оптимальных методов защиты от коррозийного разрушительного воздействия. В статье представлены типы коррозии, каким могут подвергаться отдельные элементы установок пожаротушения и пожарной арматуры, на которые воздействуют в...

  7. Author Details

    African Journals Online (AJOL)

    McCarthy, Greg. Vol 15, No 1 (2001): Media Freedom and Human Rights - Articles Caught between Empires: Ambivalence in Australian Films Details. ISSN: 0256-004. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and ...

  8. Author Details

    African Journals Online (AJOL)

    Ligthelm, A.A.. Vol 5, No 2 (2001) - Articles Community attitudes towards Casinos and the estimated magnitude of problem gambling The Mpumalanga case. Details PDF. ISSN: 1027-4332. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  9. Author Details

    African Journals Online (AJOL)

    Comarof, Jean. Vol 1999, No 3-4 (1999) - Articles Alien-Nation: Zombies, Immigrants and Millennial Capitalism Details. ISSN: 0850-8712. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact ...

  10. Author Details

    African Journals Online (AJOL)

    Njubi, Francis. Vol 15, No 1 (2001): Media Freedom and Human Rights - Articles New Media, Old Struggles: Pan Africanism, Anti-racism and Information Technology Details. ISSN: 0256-004. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  11. Author Details

    African Journals Online (AJOL)

    Journal Home > Advanced Search > Author Details. Log in or Register to get access to full text downloads. ... Okeke, EO. Vol 10 (2006) - Articles Analysis of Stokes waves theory as a diffusion problem. Abstract · Vol 11 (2007) - Articles On the impact of wave-current on Stokes waves. Abstract. ISSN: 1116-4336. AJOL African ...

  12. Author Details

    African Journals Online (AJOL)

    Love, Alison. Vol 29, No 2 (2002) - Articles Policy-makers, the Press and Politics: Reporting a Public Policy Document Details. ISSN: 0379-0622. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use ...

  13. Author Details

    African Journals Online (AJOL)

    Idowu, OO. Vol 8, No 1 (2003) - Articles Evaluation of Different Substrates and Combinations on the Growth of Pleurotus pulmonarius (Fries) Quelet (Sajor-caju) Details. ISSN: 1118-2733. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  14. Author Details

    African Journals Online (AJOL)

    Odigie, IP. Vol 10, No 4 (2000) - Articles High dose vitamin E administration attenuates hypertensin in 2-Kidney 1 Clip Goldblatt hypertensive rats. Details. ISSN: 0189-2657. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms ...

  15. Methods for the sodium cooled fast reactor fire safety provisions

    International Nuclear Information System (INIS)

    Gryaznov, B.V.; Dergachev, N.P.

    1983-01-01

    Problems of fire safety provision on NPPs with sodium cooled fast reactor are under discussion. Methods of sodium leak localization, measures eliminating sodium flaring up during leaks and main means of sodium fire extinguishing are considered. An extinguishing of sodium flaring up is performed by means of sodium temperatUre decrease and by limitation of hydrogen access to the flaring up surface. A conclusion is made that the most effective methods of extinguishing are the following: self-extinguishing (due to hydrogen burning out in a limiting volume); extinguishing by a gas mixture of nitrogen and carbonic acid (initial filling and blowing of rooms during sodium flaring up); extinguishing by special powders

  16. Verifying detailed fluctuation relations for discrete feedback-controlled quantum dynamics

    Science.gov (United States)

    Camati, Patrice A.; Serra, Roberto M.

    2018-04-01

    Discrete quantum feedback control consists of a managed dynamics according to the information acquired by a previous measurement. Energy fluctuations along such dynamics satisfy generalized fluctuation relations, which are useful tools to study the thermodynamics of systems far away from equilibrium. Due to the practical challenge to assess energy fluctuations in the quantum scenario, the experimental verification of detailed fluctuation relations in the presence of feedback control remains elusive. We present a feasible method to experimentally verify detailed fluctuation relations for discrete feedback control quantum dynamics. Two detailed fluctuation relations are developed and employed. The method is based on a quantum interferometric strategy that allows the verification of fluctuation relations in the presence of feedback control. An analytical example to illustrate the applicability of the method is discussed. The comprehensive technique introduced here can be experimentally implemented at a microscale with the current technology in a variety of experimental platforms.

  17. Author Details

    African Journals Online (AJOL)

    EKPA, O. D.. Vol 7, No 2 (2001) - Articles Variental differences AND polymorphism in palm oil: a case study of palm oils blended with coconut oil. Details PDF. ISSN: 1118-0579. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners ...

  18. Author Details

    African Journals Online (AJOL)

    Kioni, P N. Vol 9, No 1 (2007) - Articles Detailed structure of pipe flow with water hammer oscillations. Abstract. ISSN: 1561-7645. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL ...

  19. Author Details

    African Journals Online (AJOL)

    Legwaila, GM. Vol 12 (2003) - Articles Review of sweet sorghum: a potential cash and forage crop in Botswana Details. ISSN: 1021-0873. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact ...

  20. Author Details

    African Journals Online (AJOL)

    Akum, ZE. Vol 1, No 3 (2001) - Articles Basic home range characteristics for the conservation of the African grey parrot in the Korup national park, Cameroon Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms ...

  1. Author Details

    African Journals Online (AJOL)

    Bobcokono, Irene Yatabene. Vol 1, No 1 (2001) - Articles Utilisation du papier filtre dans la gestion de programme de lute contre le SIDA au Cameroun Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and ...

  2. Author Details

    African Journals Online (AJOL)

    Erasmus, GJ. Vol 1, No 1 (2001) - Articles Genetic parameter estimates for growth traits in purebred Gudali and two-breed synthetic Wakwa beef cattle in a tropical environment. Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  3. Detailed reconstruction of the nervous and muscular system of Lobatocerebridae with an evaluation of its annelid affinity.

    Science.gov (United States)

    Kerbl, Alexandra; Bekkouche, Nicolas; Sterrer, Wolfgang; Worsaae, Katrine

    2015-12-10

    The microscopic worm group Lobatocerebridae has been regarded a 'problematicum', with the systematic relationship being highly debated until a recent phylogenomic study placed them within annelids (Curr Biol 25: 2000-2006, 2015). To date, a morphological comparison with other spiralian taxa lacks detailed information on the nervous and muscular system, which is here presented for Lobatocerebrum riegeri n. sp. based on immunohistochemistry and confocal laser scanning microscopy, supported by TEM and live observations. The musculature is organized as a grid of longitudinal muscles and transverse muscular ring complexes in the trunk. The rostrum is supplied by longitudinal muscles and only a few transverse muscles. The intraepidermal central nervous system consists of a big, multi-lobed brain, nine major nerve bundles extending anteriorly into the rostrum and two lateral and one median cord extending posteriorly to the anus, connected by five commissures. The glandular epidermis has at least three types of mucus secreting glands and one type of adhesive unicellular glands. No exclusive "annelid characters" could be found in the neuromuscular system of Lobatocerebridae, except for perhaps the mid-ventral nerve. However, none of the observed structures disputes its position within this group. The neuromuscular and glandular system of L. riegeri n. sp. shows similarities to those of meiofaunal annelids such as Dinophilidae and Protodrilidae, yet likewise to Gnathostomulida and catenulid Platyhelminthes, all living in the restrictive interstitial environment among sand grains. It therefore suggests an extreme evolutionary plasticity of annelid nervous and muscular architecture, previously regarded as highly conservative organ systems throughout metazoan evolution.

  4. Technical basis for the ITER detailed design report, cost review and safety analysis (DDR)

    International Nuclear Information System (INIS)

    1997-01-01

    The ITER Detailed Design Report (DDR), Cost Review and Safety Analysis is the 3rd major milestone representing the progress made in the ITER Engineering Design Activities. With the approval of the Interim Design Report (IDR), it has been possible to freeze the main concepts and system approaches for ITER and to develop the design in more detail for the individual components and sub-systems. This report, although designed to be fully understandable as a separate document, focusses particularly on the main changes since the IDR

  5. A novel and facile strategy for highly flame retardant polymer foam composite materials: Transforming silicone resin coating into silica self-extinguishing layer.

    Science.gov (United States)

    Wu, Qian; Zhang, Qian; Zhao, Li; Li, Shi-Neng; Wu, Lian-Bin; Jiang, Jian-Xiong; Tang, Long-Cheng

    2017-08-15

    In this study, a novel strategy was developed to fabricate highly flame retardant polymer foam composite materials coated by synthesized silicone resin (SiR) polymer via a facile dip-coating processing. Applying the SiR polymer coating, the mechanical property and thermal stability of SiR-coated polymer foam (PSiR) composites are greatly enhanced without significantly altering their structure and morphology. The minimum oxygen concentration to support the combustion of foam materials is greatly increased, i.e. from LOI 14.6% for pure foam to LOI 26-29% for the PSiR composites studied. Especially, adjusting pendant group to SiOSi group ratio (R/Si ratio) of SiRs produces highly flame retardant PSiR composites with low smoke toxicity. Cone calorimetry results demonstrate that 44-68% reduction in the peak heat release rate for the PSiR composites containing different R/Si ratios over pure foam is achieved by the presence of appropriate SiR coating. Digital and SEM images of post-burn chars indicate that the SiR polymer coating can be transformed into silica self-extinguishing porous layer as effective inorganic barrier effect, thus preserving the polymer foam structure from fire. Our results show that the SiR dip-coating technique is a promising strategy for producing flame retardant polymer foam composite materials with improved mechanical properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Mine shaft fire and smoke protection systems - an update on hardware development and in-mine testing

    International Nuclear Information System (INIS)

    Johnson, G.A.

    1982-01-01

    In 1976, The Bureau of Mines developed a prototype system to sense and extinguish fires in shafts and shaft stations in underground metal and nonmetal mines. Subsequent work modified this technology to include fueling areas, spontaneous combustion zones and coal mines. This paper updates IC-8783 ''In-mine Fire Tests of Mine Shaft Fire and Smoke Protection Systems'', which was published in 1978 and summarized the design and in-mine, actual fire testing of the first prototype mine shaft fire and smoke protection system. This paper also updates related work from IC-8775 ''Spontaneous Oxidation and Combustion of Sulfide Ores in Underground Mines, (also published in 1978) and IC-8808 ''In-mine Evaluation of Underground Fire and Smoke Detectors'', (published in early 1979)

  7. Technical basis for the ITER detailed design report, cost review and safety analysis (DDR)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The ITER Detailed Design Report (DDR), Cost Review and Safety Analysis is the 3rd major milestone representing the progress made in the ITER Engineering Design Activities. With the approval of the Interim Design Report (IDR), it has been possible to freeze the main concepts and system approaches for ITER and to develop the design in more detail for the individual components and sub-systems. This report, although designed to be fully understandable as a separate document, focusses particularly on the main changes since the IDR. Refs, figs, tabs

  8. Performance/Design Requirements and Detailed Technical Description for a Computer-Directed Training Subsystem for Integration into the Air Force Phase II Base Level System.

    Science.gov (United States)

    Butler, A. K.; And Others

    The performance/design requirements and a detailed technical description for a Computer-Directed Training Subsystem to be integrated into the Air Force Phase II Base Level System are described. The subsystem may be used for computer-assisted lesson construction and has presentation capability for on-the-job training for data automation, staff, and…

  9. Cold Vacuum Dryer (CVD) Facility Fire Protection System Design Description (SYS 24)

    Energy Technology Data Exchange (ETDEWEB)

    SINGH, G.

    2000-10-17

    This system design description (SDD) addresses the Cold Vacuum Drying (CVD) Facility fire protection system (FPS). The primary features of the FPS for the CVD are a fire alarm and detection system, automatic sprinklers, and fire hydrants. The FPS also includes fire extinguishers located throughout the facility and fire hydrants to assist in manual firefighting efforts. In addition, a fire barrier separates the operations support (administrative) area from the process bays and process bay support areas. Administrative controls to limit combustible materials have been established and are a part of the overall fire protection program. The FPS is augmented by assistance from the Hanford Fire Department (HED) and by interface systems including service water, electrical power, drains, instrumentation and controls. This SDD, when used in conjunction with the other elements of the definitive design package, provides a complete picture of the FPS for the CVD Facility.

  10. A detailed description of the implementation of inpatient insulin orders with a commercial electronic health record system.

    Science.gov (United States)

    Neinstein, Aaron; MacMaster, Heidemarie Windham; Sullivan, Mary M; Rushakoff, Robert

    2014-07-01

    In the setting of Meaningful Use laws and professional society guidelines, hospitals are rapidly implementing electronic glycemic management order sets. There are a number of best practices established in the literature for glycemic management protocols and programs. We believe that this is the first published account of the detailed steps to be taken to design, implement, and optimize glycemic management protocols in a commercial computerized provider order entry (CPOE) system. Prior to CPOE implementation, our hospital already had a mature glycemic management program. To transition to CPOE, we underwent the following 4 steps: (1) preparation and requirements gathering, (2) design and build, (3) implementation and dissemination, and (4) optimization. These steps required more than 2 years of coordinated work between physicians, nurses, pharmacists, and programmers. With the move to CPOE, our complex glycemic management order sets were successfully implemented without any significant interruptions in care. With feedback from users, we have continued to refine the order sets, and this remains an ongoing process. Successful implementation of glycemic management protocols in CPOE is dependent on broad stakeholder input and buy-in. When using a commercial CPOE system, there may be limitations of the system, necessitating workarounds. There should be an upfront plan to apply resources for continuous process improvement and optimization after implementation. © 2014 Diabetes Technology Society.

  11. Devil in the details? Developmental dyslexia and visual long-term memory for details.

    Science.gov (United States)

    Huestegge, Lynn; Rohrßen, Julia; van Ermingen-Marbach, Muna; Pape-Neumann, Julia; Heim, Stefan

    2014-01-01

    Cognitive theories on causes of developmental dyslexia can be divided into language-specific and general accounts. While the former assume that words are special in that associated processing problems are rooted in language-related cognition (e.g., phonology) deficits, the latter propose that dyslexia is rather rooted in a general impairment of cognitive (e.g., visual and/or auditory) processing streams. In the present study, we examined to what extent dyslexia (typically characterized by poor orthographic representations) may be associated with a general deficit in visual long-term memory (LTM) for details. We compared object- and detail-related visual LTM performance (and phonological skills) between dyslexic primary school children and IQ-, age-, and gender-matched controls. The results revealed that while the overall amount of LTM errors was comparable between groups, dyslexic children exhibited a greater portion of detail-related errors. The results suggest that not only phonological, but also general visual resolution deficits in LTM may play an important role in developmental dyslexia.

  12. NSTX-U Digital Coil Protection System Software Detailed Design

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-06-01

    The National Spherical Torus Experiment (NSTX) currently uses a collection of analog signal processing solutions for coil protection. Part of the NSTX Upgrade (NSTX-U) entails replacing these analog systems with a software solution running on a conventional computing platform. The new Digital Coil Protection System (DCPS) will replace the old systems entirely, while also providing an extensible framework that allows adding new functionality as desired.

  13. Dosimetry and optimization in digital radiography based on the detail contrast resolution

    Energy Technology Data Exchange (ETDEWEB)

    Gomes B, W. O. [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho 40301-015, Salvador de Bahia (Brazil); Gomes de C, A., E-mail: wilsonottobatista@gmail.com [Secretaria de Saude do Estado da Bahia, Salvador de Bahia (Brazil)

    2016-10-15

    In digital radiography, computed radiography systems (CR) and portable panels a-Si (DR) are adapted to equipment previously used for the system screen / film. Therefore it maintains the characteristics as grid, filtration, yield, etc. Otherwise, the systems dedicated with a-Si panels (DR), are designed to operate with these image receptors. The ability to detect in low contrast details is reduced for all systems with increasing ratio of scattered radiation / primary radiation. In this context there is a need to acquire experience and adjust exposure protocols to ensure the quality of the image with maintaining kerma values in the surface as low as possible. The contrast resolution is defined as the ability of the system to distinguish similar degrees of attenuation of the object and is a parameter used to maintain the quality index and comparison between different systems. The protocols were: chest (90 and 102 kV with the range of 2-20 m As) and abdomen (80 kV in the range of 10-80 m As). Kerma values were evaluated with a solid state sensors. Based on analysis of these curves C-D, which identified the technique would imply a lower kerma input surface while maintaining image quality from the point of view of contrast-detail resolution. The results show that the IQFinv varies little throughout the range of m As, while the value of kerma varies linearly with in m As. Also, the complete analysis of the curves indicate that there was an increase in the definition of detail with increasing m As. The conclusion is that, in the transition phase of the new receivers are needed to assess and adjust practiced protocols to ensure the quality index of the image taking into account aspects of radiation protection of the patient. And even with digital technology, good radiographic technique should be practiced. (Author)

  14. Rapid prototyping in order to improve building performance simulation for detailed design support

    NARCIS (Netherlands)

    Hopfe, C.J.; Hensen, J.L.M.; Stankov, P.

    2006-01-01

    Building performance simulation (BPS) is a powerful tool to support building and system designers in emulating how orientation, building type, HVAC system etc. interacts the overall building performance. Currently BPS is used only for code compliance in the detailed design, neither to make informed

  15. PG BN 1600 sodium fire protection system

    International Nuclear Information System (INIS)

    Bar, J.; Urbancik, L.

    1978-12-01

    A design was developed of a fire protection system for steam generator of a 1600 MW sodium cooled fast reactor (BN-1600). Chemical reactions are described of liquid sodium with atmospheric components and solid materials coming into contact with sodium in its release from the steam generator, and in safeguarding protection against sodium fires. The requirements for the purity of nitrogen as an atmosphere inert to liquid sodium are given. Characteristics and basic parameters are shown of level and spray fires, elementary terms are explained concerning the properties of aerosols formed during fires, the methods and means of release signalling and fire alarm are described as are fire precautions using fire-fighting equipment, modifying the support tank and the cell bottom and building sewage pits. The design of the system comprises an alarm system for liquid sodium using point and line electric contact sensors and flame photometer based aerosol sensors as well as a fire-fighting system based on the system of channelling liquid sodium into emergency discharge tanks filled with an inert gas, a set of fire extinguishers and other fire fighting material, and measures for the elimination of sodium fire consequences. (J.B.)

  16. Devil in the Details? Developmental Dyslexia and Visual Long-Term Memory for Details

    Directory of Open Access Journals (Sweden)

    Lynn eHuestegge

    2014-07-01

    Full Text Available Cognitive theories on causes of developmental dyslexia can be divided into language-specific and general accounts. While the former assume that words are special in that associated processing problems are rooted in language-related cognition (e.g., phonology deficits, the latter propose that dyslexia is rather rooted in a general impairment of cognitive (e.g., visual and/or auditory processing streams. In the present study, we examined to what extent dyslexia (typically characterized by poor orthographic representations may be associated with a general deficit in visual long-term memory for details. We compared object- and detail-related visual long-term memory performance (and phonological skills between dyslexic primary school children and IQ-, age- and gender-matched controls. The results revealed that while the overall amount of long-term memory errors was comparable between groups, dyslexic children exhibited a greater portion of detail-related errors. The results suggest that not only phonological, but also general visual resolution deficits in long-term memory may play an important role in developmental dyslexia.

  17. Detailed radon emanation mapping in Northern Latium

    International Nuclear Information System (INIS)

    Aumento, F.

    1993-01-01

    Detailed radon surveys over 5,000 km 2 of Northern Latium, covering the northern part of the volcanic province of Central Italy, commenced in the mid eighties as part of a geothermal exploration programme; the surveys have subsequently been continued and amplified with environmental protection in mind. The area is now covered by ground emission maps, radon levels in water supplies, emissions from the different lithologies and concentrations in houses. The high uraniferous content of the volcanics, the porous nature of the ubiquitous pyroclastics, and active geothermal systems in the area combine to convey to ground level high concentrations of radon. The emissions show strong lateral variations which are geologically and tectonically controlled, such that only detailed surveys reveal the extent and locations of anomalous radon emanations. Unfortunately, long ago towns often developed in strategic locations. For Northern Latium this means on volcanic highs formed by faulted tuff blocks, two geological features associated with particularly high radon emissions. As a result, in contrast to the low average indoor radon concentrations for the greater part of Italy, in some of these town the average values exceed 450 Bq/m 3 . (author). 1 fig

  18. EFFECTS OF COMPRESSED AIR FOAM APPLICATION ON HEAT

    Directory of Open Access Journals (Sweden)

    Adam THOMITZEK

    2015-12-01

    Full Text Available This article evaluates the knowledge obtained in firefighting tests using compressed air foam system (CAFS within a confined space. Six experiments were conducted for verification during the cooling of rooms and the self-extinguishing effect. The simulation was for a fully developed fire within a room. The fuel was chosen to simulate ordinary combustible materials utilized in residential areas. Mantel thermocouples were placed in the rooms to record the temperature changes. Compressed air foam was first applied with a standard fire hose nozzle to the ceiling and then to the epicenter of fire. Fire extinguishing was initiated after reaching the desired temperature in the room. The temperature for the start of fire extinguishing matched the third phase of development of a fire. Fire extinguishing was terminated after no obvious signs of fire were shown in epicenter of fire. The outputs of the experiments were evaluated on the basis of the amount of time passed for the temperature to drop below the suggested limit. Individual experiments were also conducted with various different admixing foaming agents over different locations. In the experiments, it has been verified that the application of compressed air foam has a positive effect on room cooling. Use of a compressed air foaming agent does not allow for the development of steam that can scald firefighters and reduce visibility. Furthermore, the extinguishing agent used is more efficient utilizing less water flow out of the fire area.

  19. Template Assembly for Detailed Urban Reconstruction

    KAUST Repository

    Nan, Liangliang

    2015-05-04

    We propose a new framework to reconstruct building details by automatically assembling 3D templates on coarse textured building models. In a preprocessing step, we generate an initial coarse model to approximate a point cloud computed using Structure from Motion and Multi View Stereo, and we model a set of 3D templates of facade details. Next, we optimize the initial coarse model to enforce consistency between geometry and appearance (texture images). Then, building details are reconstructed by assembling templates on the textured faces of the coarse model. The 3D templates are automatically chosen and located by our optimization-based template assembly algorithm that balances image matching and structural regularity. In the results, we demonstrate how our framework can enrich the details of coarse models using various data sets.

  20. Browns Ferry nuclear power-plant fire on March 22, 1975

    International Nuclear Information System (INIS)

    Scott, R.L.

    1976-01-01

    A review is presented of the March 22, 1975, fire at the Browns Ferry nuclear power plant. The fire originated in the electrical cable trays and burned for 7 hr before it was extinguished by water. The use of water was delayed until the reactors were in a stable shutdown condition because of the possibility of shorting circuits, which might have caused further degradation of conditions that would have been more difficult to control. However, when water was authorized, the fire was quickly extinguished. The fire-fighting efforts and the damage caused by the fire are described. The loss of electrical power and control circuits resulted in the unavailability of emergency core-cooling systems and hampered efforts to provide normal cooling to the reactor fuel. The availability of alternate cooling methods is reviewed, the efforts to maintain cooling of the reactor fuel are discussed, and the basic reasons for the common-mode failures are described. Assessments of the fire were made by three groups in the U.S. Nuclear Regulatory Commission (NRC), as well as by an independent insurance group. Some of the details of these assessments are presented, in particular, some deficiencies that the NRC Office of Inspection and Enforcement found during its investigation and some of the lessons learned from the events as determined by the NRC Special Review Group

  1. Automatic sprinkler system performance and reliability in United States Department of Energy Facilities, 1952 to 1980

    International Nuclear Information System (INIS)

    1982-06-01

    The automatic sprinkler system experiences of the United States Department of Energy and its predecessor agencies are analyzed. Based on accident and incident files in the Office of Operational Safety and on supplementary responses, 587 incidents including over 100 fires are analyzed. Tables and figures, with supplementary narratives discuss fire experience by various categories such as number of heads operating, type of system, dollar losses, failures, extinguished vs. controlled, and types of sprinkler heads. Use is made of extreme value projections and frequency-severity plots to compare past experience and predict future experience. Non-fire incidents are analyzed in a similar manner by cause, system types and failure types. Discussion of no-loss incidents and non-fire protection water systems is included. The author's conclusions and recommendations and appendices listing survey methodology, major incidents, and a bibliography are included

  2. Detailed Balance of Thermalization Dynamics in Rydberg-Atom Quantum Simulators.

    Science.gov (United States)

    Kim, Hyosub; Park, YeJe; Kim, Kyungtae; Sim, H-S; Ahn, Jaewook

    2018-05-04

    Dynamics of large complex systems, such as relaxation towards equilibrium in classical statistical mechanics, often obeys a master equation that captures essential information from the complexities. Here, we find that thermalization of an isolated many-body quantum state can be described by a master equation. We observe sudden quench dynamics of quantum Ising-like models implemented in our quantum simulator, defect-free single-atom tweezers in conjunction with Rydberg-atom interaction. Saturation of their local observables, a thermalization signature, obeys a master equation experimentally constructed by monitoring the occupation probabilities of prequench states and imposing the principle of the detailed balance. Our experiment agrees with theories and demonstrates the detailed balance in a thermalization dynamics that does not require coupling to baths or postulated randomness.

  3. Detailed Balance of Thermalization Dynamics in Rydberg-Atom Quantum Simulators

    Science.gov (United States)

    Kim, Hyosub; Park, YeJe; Kim, Kyungtae; Sim, H.-S.; Ahn, Jaewook

    2018-05-01

    Dynamics of large complex systems, such as relaxation towards equilibrium in classical statistical mechanics, often obeys a master equation that captures essential information from the complexities. Here, we find that thermalization of an isolated many-body quantum state can be described by a master equation. We observe sudden quench dynamics of quantum Ising-like models implemented in our quantum simulator, defect-free single-atom tweezers in conjunction with Rydberg-atom interaction. Saturation of their local observables, a thermalization signature, obeys a master equation experimentally constructed by monitoring the occupation probabilities of prequench states and imposing the principle of the detailed balance. Our experiment agrees with theories and demonstrates the detailed balance in a thermalization dynamics that does not require coupling to baths or postulated randomness.

  4. The systems integration modeling system

    International Nuclear Information System (INIS)

    Danker, W.J.; Williams, J.R.

    1990-01-01

    This paper discusses the systems integration modeling system (SIMS), an analysis tool for the detailed evaluation of the structure and related performance of the Federal Waste Management System (FWMS) and its interface with waste generators. It's use for evaluations in support of system-level decisions as to FWMS configurations, the allocation, sizing, balancing and integration of functions among elements, and the establishment of system-preferred waste selection and sequencing methods and other operating strategies is presented. SIMS includes major analysis submodels which quantify the detailed characteristics of individual waste items, loaded casks and waste packages, simulate the detailed logistics of handling and processing discrete waste items and packages, and perform detailed cost evaluations

  5. Engineered safeguards and passive safety features (safety analysis detailed report no. 6)

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-15

    The Safety-Analysis Summary lists the reactor's safety aspects for passive and active prevention of severe accidents and mitigation of accident consequences, i.e., intrinsic and passive protections of the plant; intrinsic and passive protections of the core; inherent decay-heat removal systems; rapid-shutdown systems; four physical containment barriers. This report goes into further details regarding some of this aspects.

  6. 49 CFR 571.138 - Standard No. 138; Tire pressure monitoring systems.

    Science.gov (United States)

    2010-10-01

    ... following statement in English: Each tire, including the spare (if provided), should be checked monthly when... level to trigger illumination of the TPMS low tire pressure telltale. [The following paragraph is.... If necessary, drive the vehicle until the telltale has extinguished. (o) The test may be repeated...

  7. Template Assembly for Detailed Urban Reconstruction

    KAUST Repository

    Nan, Liangliang; Wonka, Peter; Ghanem, Bernard; Jiang, Caigui

    2015-01-01

    Structure from Motion and Multi View Stereo, and we model a set of 3D templates of facade details. Next, we optimize the initial coarse model to enforce consistency between geometry and appearance (texture images). Then, building details are reconstructed

  8. 46 CFR 108.419 - Fire main capacity.

    Science.gov (United States)

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.419 Fire main capacity. The diameter of the fire... pumps operating simultaneously. ...

  9. Optimizing a physical security configuration using a highly detailed simulation model

    NARCIS (Netherlands)

    Marechal, T.M.A.; Smith, A.E.; Ustun, V.; Smith, J.S.; Lefeber, A.A.J.; Badiru, A.B.; Thomas, M.U.

    2009-01-01

    This research is focused on using a highly detailed simulation model to create a physical security system to prevent intrusions in a building. Security consists of guards and security cameras. The problem is represented as a binary optimization problem. A new heuristic is proposed to do the security

  10. Detail in architecture: Between arts & crafts

    Science.gov (United States)

    Dulencin, Juraj

    2016-06-01

    Architectural detail represents an important part of architecture. Not only can it be used as an identifier of a specific building but at the same time enhances the experience of the realized project. Within it lie the signs of a great architect and clues to understanding his or her way of thinking. It is therefore the central topic of a seminar offered to architecture students at the Brno University of Technology. During the course of the semester-long class the students acquaint themselves with atypical architectural details of domestic and international architects by learning to read them, understand them and subsequently draw them by creating architectural blueprints. In other words, by general analysis of a detail the students learn theoretical thinking of its architect who, depending on the nature of the design, had to incorporate a variety of techniques and crafts. Students apply this analytical part to their own architectural detail design. The methodology of the seminar consists of experiential learning by project management and is complemented by a series of lectures discussing a diversity of details as well as materials and technologies required to implement it. The architectural detail design is also part of students' bachelors thesis, therefore, the realistic nature of their blueprints can be verified in the production process of its physical counterpart. Based on their own documentation the students choose the most suitable manufacturing process whether it is supplied by a specific technology or a craftsman. Students actively participate in the production and correct their design proposals in real scale with the actual material. A student, as a future architect, stands somewhere between a client and an artisan, materializes his or her idea and adjusts the manufacturing process so that the final detail fulfills aesthetic consistency and is in harmony with its initial concept. One of the very important aspects of the design is its economic cost, an

  11. A study on plate anchor detailing systems of shear re-bar

    International Nuclear Information System (INIS)

    Tsurumaki, S.; Ujiie, K.; Nishikawa, T.; Kitayama, K.

    1995-01-01

    For shell walls and base slabs in reactor buildings, besides a large amount of main bars, numerous shear re-bars have been employed to resist to out-of-plane force. As a result , detailing work involving shear re-bar is extremely involved. For example, the employed re-bar anchor method differs from the ordinary methods in which, a end of shear re-bar with 135-degrees hook or with anchor plate type and another re-bar end with 90-degrees hook are used. However the structural characteristics in members using shear re-bar of the bolt-mounted anchor plate have not yet been examined. A test was performed to confirm the effects of anchor methods for shear re-bars on shearing behavior of members. This paper describes the test plan, method and results. (author). 12 figs., 7 tabs

  12. Detailed Modeling and Evaluation of a Scalable Multilevel Checkpointing System

    Energy Technology Data Exchange (ETDEWEB)

    Mohror, Kathryn [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Moody, Adam [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bronevetsky, Greg [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); de Supinski, Bronis R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-09-01

    High-performance computing (HPC) systems are growing more powerful by utilizing more components. As the system mean time before failure correspondingly drops, applications must checkpoint frequently to make progress. But, at scale, the cost of checkpointing becomes prohibitive. A solution to this problem is multilevel checkpointing, which employs multiple types of checkpoints in a single run. Moreover, lightweight checkpoints can handle the most common failure modes, while more expensive checkpoints can handle severe failures. We designed a multilevel checkpointing library, the Scalable Checkpoint/Restart (SCR) library, that writes lightweight checkpoints to node-local storage in addition to the parallel file system. We present probabilistic Markov models of SCR's performance. We show that on future large-scale systems, SCR can lead to a gain in machine efficiency of up to 35 percent, and reduce the load on the parallel file system by a factor of two. In addition, we predict that checkpoint scavenging, or only writing checkpoints to the parallel file system on application termination, can reduce the load on the parallel file system by 20 × on today's systems and still maintain high application efficiency.

  13. Academic detailing.

    Science.gov (United States)

    Shankar, P R; Jha, N; Piryani, R M; Bajracharya, O; Shrestha, R; Thapa, H S

    2010-01-01

    There are a number of sources available to prescribers to stay up to date about medicines. Prescribers in rural areas in developing countries however, may not able to access some of them. Interventions to improve prescribing can be educational, managerial, and regulatory or use a mix of strategies. Detailing by the pharmaceutical industry is widespread. Academic detailing (AD) has been classically seen as a form of continuing medical education in which a trained health professional such as a physician or pharmacist visits physicians in their offices to provide evidence-based information. Face-to-face sessions, preferably on an individual basis, clear educational and behavioural objectives, establishing credibility with respect to objectivity, stimulating physician interaction, use of concise graphic educational materials, highlighting key messages, and when possible, providing positive reinforcement of improved practices in follow-up visits can increase success of AD initiatives. AD is common in developed countries and certain examples have been cited in this review. In developing countries the authors have come across reports of AD in Pakistan, Sudan, Argentina and Uruguay, Bihar state in India, Zambia, Cuba, Indonesia and Mexico. AD had a consistent, small but potentially significant impact on prescribing practices. AD has much less resources at its command compared to the efforts by the industry. Steps have to be taken to formally start AD in Nepal and there may be specific hindering factors similar to those in other developing nations.

  14. Detailed Performance Study of ATLAS Endcap Muon Trigger with Beam Collision Data

    CERN Document Server

    Hayakawa, T

    2010-01-01

    In 2009 the first beam collision was occurred at the LHC and the ATLAS has started data taking with beam collision at s = 7 TeV since May 2010. This poster will mention the contraptions to take the beam collision data for the electronics of Level1 Endcap Muon Trigger system, and the result and detailed study of LVL1 Endcap Muon Trigger system performance with beam collision.

  15. The effect of a loss of model structural detail due to network skeletonization on contamination warning system design: case studies

    Science.gov (United States)

    Davis, Michael J.; Janke, Robert

    2018-05-01

    The effect of limitations in the structural detail available in a network model on contamination warning system (CWS) design was examined in case studies using the original and skeletonized network models for two water distribution systems (WDSs). The skeletonized models were used as proxies for incomplete network models. CWS designs were developed by optimizing sensor placements for worst-case and mean-case contamination events. Designs developed using the skeletonized network models were transplanted into the original network model for evaluation. CWS performance was defined as the number of people who ingest more than some quantity of a contaminant in tap water before the CWS detects the presence of contamination. Lack of structural detail in a network model can result in CWS designs that (1) provide considerably less protection against worst-case contamination events than that obtained when a more complete network model is available and (2) yield substantial underestimates of the consequences associated with a contamination event. Nevertheless, CWSs developed using skeletonized network models can provide useful reductions in consequences for contaminants whose effects are not localized near the injection location. Mean-case designs can yield worst-case performances similar to those for worst-case designs when there is uncertainty in the network model. Improvements in network models for WDSs have the potential to yield significant improvements in CWS designs as well as more realistic evaluations of those designs. Although such improvements would be expected to yield improved CWS performance, the expected improvements in CWS performance have not been quantified previously. The results presented here should be useful to those responsible for the design or implementation of CWSs, particularly managers and engineers in water utilities, and encourage the development of improved network models.

  16. Escape rate for nonequilibrium processes dominated by strong non-detailed balance force

    Science.gov (United States)

    Tang, Ying; Xu, Song; Ao, Ping

    2018-02-01

    Quantifying the escape rate from a meta-stable state is essential to understand a wide range of dynamical processes. Kramers' classical rate formula is the product of an exponential function of the potential barrier height and a pre-factor related to the friction coefficient. Although many applications of the rate formula focused on the exponential term, the prefactor can have a significant effect on the escape rate in certain parameter regions, such as the overdamped limit and the underdamped limit. There have been continuous interests to understand the effect of non-detailed balance on the escape rate; however, how the prefactor behaves under strong non-detailed balance force remains elusive. In this work, we find that the escape rate formula has a vanishing prefactor with decreasing friction strength under the strong non-detailed balance limit. We both obtain analytical solutions in specific examples and provide a derivation for more general cases. We further verify the result by simulations and propose a testable experimental system of a charged Brownian particle in electromagnetic field. Our study demonstrates that a special care is required to estimate the effect of prefactor on the escape rate when non-detailed balance force dominates.

  17. 46 CFR 115.702 - Installation tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... CERTIFICATION Repairs and Alterations § 115.702 Installation tests and inspections. Whenever a launching appliance, survival craft, rescue boat, fixed gas fire extinguishing system, machinery, fuel tank, or...

  18. Liquid metals fire control engineering handbook

    International Nuclear Information System (INIS)

    Ballif, J.L.

    1979-02-01

    This handbook reviews the basic requirements of the use of liquid metals with emphasis on sodium which has the greatest current usage. It delineates the concepts necessary to design facilities both radioactive and nonradioactive for use with liquid metals. It further reviews the state-of-the-art in fire extinguishers and leak detection equipment and comments on their application and sensitivity. It also provides details on some engineering features of value to the designer of liquid metal facilities

  19. Detailed Soils 24K

    Data.gov (United States)

    Kansas Data Access and Support Center — This data set is a digital soil survey and is the most detailed level of soil geographic data developed by the National Cooperative Soil Survey. The information was...

  20. Detailed Facility Report Data Dictionary | ECHO | US EPA

    Science.gov (United States)

    The Detailed Facility Report Data Dictionary provides users with a list of the variables and definitions that have been incorporated into the Detailed Facility Report. The Detailed Facility Report provides a concise enforcement and compliance history for a facility.

  1. Recovering and Preventing Loss of Detailed Memory: Differential Rates of Forgetting for Detail Types in Episodic Memory

    Science.gov (United States)

    Sekeres, Melanie J.; Bonasia, Kyra; St-Laurent, Marie; Pishdadian, Sara; Winocur, Gordon; Grady, Cheryl; Moscovitch, Morris

    2016-01-01

    Episodic memories undergo qualitative changes with time, but little is known about how different aspects of memory are affected. Different types of information in a memory, such as perceptual detail, and central themes, may be lost at different rates. In patients with medial temporal lobe damage, memory for perceptual details is severely impaired,…

  2. Detailed description of an SSAC at the facility level for research reactors

    International Nuclear Information System (INIS)

    Jones, R.J.

    1984-09-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in a research reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  3. Making detailed predictions makes (some) predictions worse

    Science.gov (United States)

    Kelly, Theresa F.

    In this paper, we investigate whether making detailed predictions about an event makes other predictions worse. Across 19 experiments, 10,895 participants, and 415,960 predictions about 724 professional sports games, we find that people who made detailed predictions about sporting events (e.g., how many hits each baseball team would get) made worse predictions about more general outcomes (e.g., which team would win). We rule out that this effect is caused by inattention or fatigue, thinking too hard, or a differential reliance on holistic information about the teams. Instead, we find that thinking about game-relevant details before predicting winning teams causes people to give less weight to predictive information, presumably because predicting details makes information that is relatively useless for predicting the winning team more readily accessible in memory and therefore incorporated into forecasts. Furthermore, we show that this differential use of information can be used to predict what kinds of games will and will not be susceptible to the negative effect of making detailed predictions.

  4. Detailed Physical Trough Model for NREL's Solar Advisor Model: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M. J.; Blair, N.; Dobos, A.

    2010-10-01

    Solar Advisor Model (SAM) is a free software package made available by the National Renewable Energy Laboratory (NREL), Sandia National Laboratory, and the US Department of Energy. SAM contains hourly system performance and economic models for concentrating solar power (CSP) systems, photovoltaic, solar hot-water, and generic fuel-use technologies. Versions of SAM prior to 2010 included only the parabolic trough model based on Excelergy. This model uses top-level empirical performance curves to characterize plant behavior, and thus is limited in predictive capability for new technologies or component configurations. To address this and other functionality challenges, a new trough model; derived from physical first principles was commissioned to supplement the Excelergy-based empirical model. This new 'physical model' approaches the task of characterizing the performance of the whole parabolic trough plant by replacing empirical curve-fit relationships with more detailed calculations where practical. The resulting model matches the annual performance of the SAM empirical model (which has been previously verified with plant data) while maintaining run-times compatible with parametric analysis, adding additional flexibility in modeled system configurations, and providing more detailed performance calculations in the solar field, power block, piping, and storage subsystems.

  5. Double Exponential Instability of Triangular Arbitrage Systems

    OpenAIRE

    Cross, Rod; Kozyakin, Victor

    2012-01-01

    If financial markets displayed the informational efficiency postulated in the efficient markets hypothesis (EMH), arbitrage operations would be self-extinguishing. The present paper considers arbitrage sequences in foreign exchange (FX) markets, in which trading platforms and information are fragmented. In Kozyakin et al. (2010) and Cross et al. (2012) it was shown that sequences of triangular arbitrage operations in FX markets containing 4 currencies and trader-arbitrageurs tend to display p...

  6. Recent developments in the detailed modelling of power house environmental conditions using GOTHIC

    International Nuclear Information System (INIS)

    Wong, R.C.; Fluke, R.J.; Yim, K.; Rossitter, B.G.

    1997-01-01

    Environmental qualification of safety equipment in the powerhouse requires detailed information on the predicted harsh conditions that can arise following a steam line break. Although lumped parameter codes provide quick assessments of global conditions, the results are unsatisfactory because the spatial detail needed to evaluate specific equipment, or indeed to optimize and confirm the design adequacy of mitigating features, is not available. To overcome these problems, new models have been developed to provide detailed three-dimensional information using the GOTHIC code. Furthermore, new animated graphical displays help the designer visualize and fully comprehend the buoyancy driven steam flow within the powerhouse. This has lead to quick optimization of the placement, size and opening time of the emergency venting system, thereby mitigating the conditions for which safety equipment must be qualified. This has resulted in significant cost savings for the environmental qualification programme. (author)

  7. Normalization of water flow rate for external fire fighting of the buildings in settlements with zone water supply

    Directory of Open Access Journals (Sweden)

    Deryushev Leonid Georgievich

    2014-12-01

    Full Text Available In the article the requirements for fire safety assurance are justified for the objects, in which water is supplied with account for serial and parallel area zoning. In the process of zoning the district is segregated into such parts, for which head rate in any point of selection of water from network will not exceed 6 bar. In the current regulatory rules the requirements for the calculation of the costs of water points are stated, as well as in case of extinguishing fires at the sites with water-supply systems zones. It is recommended to analyze each zone of the system of water-supply separately, without interrelation with the common water feeders, water consumers and services of fire extinguishing. Such an approach to assign water discharge for fire extinguishing results in the decrease of fire safety of an object, deforms calculation technique of outside systems of water-supply of the similar-type objects located in different parts of the terrain. Taking the number of fires and water consumption for fire suppression by the number of residents in each zone, we thus underestimate the capacity of the pipeline system. It is offered to make changes in Norms and Standards in force on fire safety of settlements. The recommendations on regulation of the number of fires and water flow for fire fighting in residential objects with zoned systems of water-supply are formulated.

  8. Crowdsourcing detailed flood data

    Science.gov (United States)

    Walliman, Nicholas; Ogden, Ray; Amouzad*, Shahrzhad

    2015-04-01

    Over the last decade the average annual loss across the European Union due to flooding has been 4.5bn Euros, but increasingly intense rainfall, as well as population growth, urbanisation and the rising costs of asset replacements, may see this rise to 23bn Euros a year by 2050. Equally disturbing are the profound social costs to individuals, families and communities which in addition to loss of lives include: loss of livelihoods, decreased purchasing and production power, relocation and migration, adverse psychosocial effects, and hindrance of economic growth and development. Flood prediction, management and defence strategies rely on the availability of accurate information and flood modelling. Whilst automated data gathering (by measurement and satellite) of the extent of flooding is already advanced it is least reliable in urban and physically complex geographies where often the need for precise estimation is most acute. Crowdsourced data of actual flood events is a potentially critical component of this allowing improved accuracy in situations and identifying the effects of local landscape and topography where the height of a simple kerb, or discontinuity in a boundary wall can have profound importance. Mobile 'App' based data acquisition using crowdsourcing in critical areas can combine camera records with GPS positional data and time, as well as descriptive data relating to the event. This will automatically produce a dataset, managed in ArcView GIS, with the potential for follow up calls to get more information through structured scripts for each strand. Through this local residents can provide highly detailed information that can be reflected in sophisticated flood protection models and be core to framing urban resilience strategies and optimising the effectiveness of investment. This paper will describe this pioneering approach that will develop flood event data in support of systems that will advance existing approaches such as developed in the in the UK

  9. Calibrating Detailed Chemical Analysis of M dwarfs

    Science.gov (United States)

    Veyette, Mark; Muirhead, Philip Steven; Mann, Andrew; Brewer, John; Allard, France; Homeier, Derek

    2018-01-01

    The ability to perform detailed chemical analysis of Sun-like F-, G-, and K-type stars is a powerful tool with many applications including studying the chemical evolution of the Galaxy, assessing membership in stellar kinematic groups, and constraining planet formation theories. Unfortunately, complications in modeling cooler stellar atmospheres has hindered similar analysis of M-dwarf stars. Large surveys of FGK abundances play an important role in developing methods to measure the compositions of M dwarfs by providing benchmark FGK stars that have widely-separated M dwarf companions. These systems allow us to empirically calibrate metallicity-sensitive features in M dwarf spectra. However, current methods to measure metallicity in M dwarfs from moderate-resolution spectra are limited to measuring overall metallicity and largely rely on astrophysical abundance correlations in stellar populations. In this talk, I will discuss how large, homogeneous catalogs of precise FGK abundances are crucial to advancing chemical analysis of M dwarfs beyond overall metallicity to direct measurements of individual elemental abundances. I will present a new method to analyze high-resolution, NIR spectra of M dwarfs that employs an empirical calibration of synthetic M dwarf spectra to infer effective temperature, Fe abundance, and Ti abundance. This work is a step toward detailed chemical analysis of M dwarfs at a similar precision achieved for FGK stars.

  10. Ciência de espumas - aplicação na extinção de incêndios

    Directory of Open Access Journals (Sweden)

    Figueredo Rita C. R.

    1999-01-01

    Full Text Available The structural characteristics of foams are responsible for a broad range of applications of this system. Foams produced by aqueous solutions of surfactant concentrates are used in fire-fighting due to their special properties as extinguishing agents. In the present paper we discuss the main aspects involved in fire-fighting, based on some properties of foams. Thermal and chemical stability, good wetting of surfaces, cooling effect by water drained from the bubbles, isolation of the air from the burning surface and suppression of flammable vapors are some of the factors involved in the extinguishment of fire by foams.

  11. Detailed description of an SSAC at the facility level for a low-enriched uranium conversion and fuel fabrication facility

    International Nuclear Information System (INIS)

    Jones, R.J.

    1984-09-01

    Some States have expressed a need for more detailed guidance with regard to the technical elements in the design and operation of SSACs for both the national and the international objectives. To meet this need the present document has been prepared, describing the technical elements of an SSAC in considerable detail. The purpose of this document is therefore, to provide a detailed description of a system for the accounting for and control of nuclear material in a model low enriched uranium conversion and fuel fabrication facility which can be used by a facility operator to establish his own system in a way which will provide the necessary information for compliance with a national system for nuclear material accounting and control and for the IAEA to carry out its safeguards responsibilities

  12. A technique for improved stability of adaptive feedforward controllers without detailed uncertainty measurements

    International Nuclear Information System (INIS)

    Berkhoff, A P

    2012-01-01

    Model errors in adaptive controllers for the reduction of broadband noise and vibrations may lead to unstable systems or increased error signals. Previous research on active structures with small damping has shown that the addition of a low-authority controller which increases damping in the system may lead to improved performance of an adaptive, high-authority controller. Other researchers have suggested the use of frequency dependent regularization based on measured uncertainties. In this paper an alternative method is presented that avoids the disadvantages of these methods, namely the additional complex hardware and the need to obtain detailed information on the uncertainties. An analysis is made of an adaptive feedforward controller in which a difference exists between the secondary path and the model as used in the controller. The real parts of the eigenvalues that determine the stability of the system are expressed in terms of the amount of uncertainty and the singular values of the secondary path. Modifications of the feedforward control scheme are suggested that aim to improve performance without requiring detailed uncertainty measurements. (paper)

  13. Analysis of the fire hazard in reprocessing plant UP3-A at La Hague. The case of cells containing solvents

    International Nuclear Information System (INIS)

    Hebrard, L.; Savornin, J.

    1991-11-01

    In the rooms of plant UP3-A where there are conventional fire hazards, arrangements have been taken to provide fire protection using a deterministic approach: creation of fire zones, installation of fire detection and occasionally extinguishing systems. These measures are determined by comparing the fire load density in each room with threshold levels. In the rooms where there are process-related fire hazards liable to involve radioactive materials, the fire protection measures are generally reinforced, especially if the rooms contain solvents: installation of fixed fire extinguishing systems depending on the quantity of solvent and the radioactive inventory as well as outlet fire dampers operable at high temperatures. Simultaneously, probabilistic studies of certain cells have made it possible to confirm the validity of the solutions adopted. (author)

  14. Investigating the Interaction of Graphic Organizers and Seductive Details: Can a Graphic Organizer Mitigate the Seductive-Details Effect?

    Science.gov (United States)

    Rowland-Bryant, Emily; Skinner, Christopher H.; Skinner, Amy L.; Saudargas, Richard; Robinson, Daniel H.; Kirk, Emily R.

    2009-01-01

    The interaction between seductive details (SD) and a graphic organizer (GO) was investigated. Undergraduate students (n = 207) read a target-material passage about Freud's psychosexual stages. Depending on condition, the participants also read a biographical paragraph (SD-only), viewed a graphic organizer that linked the seductive details to the…

  15. Kinetic energy budget details

    Indian Academy of Sciences (India)

    Abstract. This paper presents the detailed turbulent kinetic energy budget and higher order statistics of flow behind a surface-mounted rib with and without superimposed acoustic excitation. Pattern recognition technique is used to determine the large-scale structure magnitude. It is observed that most of the turbulence ...

  16. A new debate for Turkish physicians: e-detailing.

    Science.gov (United States)

    Ventura, Keti; Baybars, Miray; Dedeoglu, Ayla Ozhan

    2012-01-01

    The study presents an empirical analysis of the attitudes of Turkish physicians towards e-detailing practices compared to face-to-face detailing. The findings reveal that although physicians have positive attitudes toward e-detailing, on some points they are still undecided and/or have doubts. The structural model revealed that affect, convenience, and informative content influence their attitude in a positive manner, whereas the personal interaction was found to be a negative factor. Physicians' age and frequency of calls received from representatives are moderators. The present study can be seen as an addition to pharmaceutical marketing, an underresearched study field in Turkey, and e-detailing particularly.

  17. 46 CFR 28.330 - Galley hood and other fire protection equipment.

    Science.gov (United States)

    2010-10-01

    ... Stage of Construction on or After or Which Undergo a Major Conversion Completed on or After September 15... pre-engineered dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA...

  18. Detailed description of an SSAC at the facility level for research laboratory facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-08-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in a research laboratory facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  19. Advanced energy systems (APU) for large commercial aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Westenberger, A.; Bleil, J.; Arendt, M. [Airbus Deutschland GmbH, Hamburg (Germany)

    2013-06-01

    The intention of using a highly integrated component using on fuel cell technology installed on board of large commercial passenger aircraft for the generation of onboard power for the systems demand during an entire aircraft mission was subject of several studies. The results of these studies have been based on the simulation of the whole system in the context of an aircraft system environment. In front of the work stood the analyses of different fuel cell technologies and the analyses of the aircraft system environment. Today onboard power is provided on ground by an APU and in flight by the main engines. In order to compare fuel cell technology with the today's usual gas turbine operational characteristics have been analysed. A second analysis was devoted to the system demand for typical aircraft categories. The MEA system concept was supposed in all cases. The favourable concept represented an aircraft propelled by conventional engines with starter generator units, providing AC electrical power, covering in total proximately half of the power demand and a component based on fuel cell technology. This component provided electrical DC power, clean potable water, thermal energy at 180 degrees Celsius and nitrogen enriched air for fire suppression and fire extinguishing agent. In opposite of a usual gas turbine based APU, this new unit was operated as the primary power system. (orig.)

  20. Visual Memory : The Price of Encoding Details

    NARCIS (Netherlands)

    Nieuwenstein, Mark; Kromm, Maria

    2017-01-01

    Studies on visual long-term memory have shown that we have a tremendous capacity for remembering pictures of objects, even at a highly detailed level. What remains unclear, however, is whether encoding objects at such a detailed level comes at any cost. In the current study, we examined how the

  1. Three Latin Phonological Details

    DEFF Research Database (Denmark)

    Olsen, Birgit Anette

    2006-01-01

    The present paper deals with three minor details of Latin phonology: 1) the development of the initial sequence *u¿l¿-, where it is suggested that an apparent vacillation between ul- and vol-/vul- represents sandhi variants going back to the proto-language, 2) the adjectives ama¯rus ‘bitter' and ...

  2. Memory for details with self-referencing.

    Science.gov (United States)

    Serbun, Sarah J; Shih, Joanne Y; Gutchess, Angela H

    2011-11-01

    Self-referencing benefits item memory, but little is known about the ways in which referencing the self affects memory for details. Experiment 1 assessed whether the effects of self-referencing operate only at the item, or general, level or whether they also enhance memory for specific visual details of objects. Participants incidentally encoded objects by making judgements in reference to the self, a close other (one's mother), or a familiar other (Bill Clinton). Results indicate that referencing the self or a close other enhances both specific and general memory. Experiments 2 and 3 assessed verbal memory for source in a task that relied on distinguishing between different mental operations (internal sources). The results indicate that self-referencing disproportionately enhances source memory, relative to conditions referencing other people, semantic, or perceptual information. We conclude that self-referencing not only enhances specific memory for both visual and verbal information, but can also disproportionately improve memory for specific internal source details.

  3. Phase Behavior of a Phospholipid/Fatty Acid/Water Mixture Studied in Atomic Detail

    NARCIS (Netherlands)

    Knecht, Volker; Mark, Alan E.; Marrink, Siewert-Jan

    2006-01-01

    Molecular dynamics simulations have been used to study the phase behavior of a dipalmitoylphosphatidylcholine (DPPC)/palmitic acid (PA)/water 1:2:20 mixture in atomic detail. Starting from a random solution of DPPC and PA in water, the system adopts either a gel phase at temperatures below similar

  4. Older adults report moderately more detailed autobiographical memories.

    Science.gov (United States)

    Gardner, Robert S; Mainetti, Matteo; Ascoli, Giorgio A

    2015-01-01

    Autobiographical memory (AM) is an essential component of the human mind. Although the([A-z]+) amount and types of subjective detail (content) that compose AMs constitute important dimensions of recall, age-related changes in memory content are not well characterized. Previously, we introduced the Cue-Recalled Autobiographical Memory test (CRAM; see http://cramtest.info), an instrument that collects subjective reports of AM content, and applied it to college-aged subjects. CRAM elicits AMs using naturalistic word-cues. Subsequently, subjects date each cued AM to a life period and count the number of remembered details from specified categories (features), e.g., temporal detail, spatial detail, persons, objects, and emotions. The current work applies CRAM to a broad range of individuals (18-78 years old) to quantify the effects of age on AM content. Subject age showed a moderately positive effect on AM content: older compared with younger adults reported ∼16% more details (∼25 vs. ∼21 in typical AMs). This age-related increase in memory content was similarly observed for remote and recent AMs, although content declined with the age of the event among all subjects. In general, the distribution of details across features was largely consistent among younger and older adults. However, certain types of details, i.e., those related to objects and sequences of events, contributed more to the age effect on content. Altogether, this work identifies a moderate age-related feature-specific alteration in the way life events are subjectively recalled, among an otherwise stable retrieval profile.

  5. Older adults report moderately more detailed autobiographical memories

    Directory of Open Access Journals (Sweden)

    Robert S Gardner

    2015-05-01

    Full Text Available Autobiographical memory (AM is an essential component of the human mind. Although the amount and types of subjective detail (content that compose AMs constitute important dimensions of recall, age-related changes in memory content are not well characterized. Previously, we introduced the Cue-Recalled Autobiographical Memory test (CRAM; see http://cramtest.info, an instrument that collects subjective reports of AM content, and applied it to college-aged subjects. CRAM elicits AMs using naturalistic word-cues. Subsequently, subjects date each cued AM to a life period and count the number of remembered details from specified categories (features, e.g., temporal detail, spatial detail, persons, objects, and emotions. The current work applies CRAM to a broad range of individuals (18-78 years old to quantify the effects of age on AM content. Subject age showed a moderately positive effect on AM content: older compared with younger adults reported ~16% more details (~25 vs. ~21 in typical AMs. This age-related increase in memory content was similarly observed for remote and recent AMs, although content declined with the age of the event among all subjects. In general, the distribution of details across features was largely consistent among younger and older adults. However, certain types of details, i.e., those related to objects and sequences of events, contributed more to the age effect on content. Altogether, this work identifies a moderate age-related feature-specific alteration in the way life events are subjectively recalled, among an otherwise stable retrieval profile.

  6. Local address and emergency contact details

    CERN Multimedia

    2013-01-01

    The HR Department would like to remind members of the personnel that they are responsible for ensuring that their personal data concerning local address and preferred emergency contact details remains valid and up-to-date.   Both are easily accessible via the links below: Local address: https://edh.cern.ch/Document/Personnel/LocalAddressChange   Emergency contacts: https://edh.cern.ch/Document/Personnel/EC   Please take a few minutes to check your details and modify if necessary. Thank you in advance. HR Department Head Office

  7. Methodological Details and Full Bibliography

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset has several components, The first part describes fully our literature review, providing details not included in the text. The second part provides all...

  8. Moisture Migration in an Oil-Paper Insulation System in Relation to Online Partial Discharge Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Wojciech Sikorski

    2016-12-01

    Full Text Available Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats to proper operation of the transformer, e.g., ignition of partial discharges (PDs. Due to the varying temperature of the insulation system during the unit’s normal operation, a dynamic change (migration of water takes place, precipitating the oil-paper system from a state of hydrodynamic equilibrium. This causes the PDs to be variable in time, and they may intensify or extinguish. Studies on model objects have been conducted to determine the conditions (temperature, humidity, time that will have an impact on the ignition and intensity of the observed phenomenon of PDs. The conclusions of this study will have a practical application in the evaluation of measurements conducted in the field, especially in relation to the registration of an online PD monitoring system.

  9. 46 CFR 108.489 - Helicopter fueling facilities.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Helicopter fueling facilities. 108.489 Section 108.489... AND EQUIPMENT Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.489 Helicopter fueling facilities. (a) Each helicopter fueling facility must have a fire protection system that...

  10. Adoption of risk management strategies in information resources ...

    African Journals Online (AJOL)

    The study found that regular supervision and inspection of the library resources, systems and operations, installation of fire alarms systems, complete risk avoidance, installation of fire extinguishers, installation of antivirus for the computers, provision for training and retraining of library staff, availability of library amnesty ...

  11. Detailed measurements of deformation in the excavation disturbed zone

    International Nuclear Information System (INIS)

    Thompson, P.M.; Martino, J.B.; Spinney, M.H.

    1993-01-01

    An excavation damage extensometer (EDEX) is described. It was designed to enable detailed small-scale deformation measurements to be made in the excavation disturbed zone (EDZ) around a tunnel opening in stressed rock. Its use in the Mine-by Experiment in unfractured granitic rock at the Underground Research Laboratory (Manitoba) is described. The results obtained from an array of eight EDEX installations are presented. These demonstrate how the EDEX can be used to provide data on the EDZ which is supplementary to that obtained by larger scale borehole extensometers and a acoustic emission/micro-seismic monitoring system. (4 figures, 5 references) (UK)

  12. THE DEVELOPMENT OF DETAILED HUMAN FACTORS ENGINEERING GUIDELINES FOR DIGITAL CONTROL ROOM UPGRADES

    International Nuclear Information System (INIS)

    BROWN, W.; O'HARA, J.M.

    2004-01-01

    As part of the Department of Energy and Electric Power Research Institute's hybrid control room project, detailed human factors engineering guidance was developed for designing human-system interfaces that may be affected by introduction of additional digital technology during modernization of nuclear power plants. The guidance addresses several aspects of human-system interaction: information display, interface management, soft controls, alarms, computer-based procedures, computerized operator support systems, communications, and workstation/workplace design. In this paper, the ways in which digital upgrades might affect users' interaction with systems in each of these contexts are briefly described, and the contents of the guidance developed for each of the topics is also described

  13. Detailed Studies of the Sculptor Dwarf Spheroidal Galaxy in the Milky Way halo

    NARCIS (Netherlands)

    Tolstoy, Eline

    In and around the Milky Way halo there are a number of low mass low luminosity dwarf galaxies. Several of these systems have been studied in great detail. I describe recent photometric and spectroscopic studies of the Sculptor dwarf spheroidal galaxy made as part of the DART survey of nearby dwarf

  14. One Curve Embedded Full-Bridge MMC Modeling Method with Detailed Representation of IGBT Characteristics

    Science.gov (United States)

    Hongyang, Yu; Zhengang, Lu; Xi, Yang

    2017-05-01

    Modular Multilevel Converter is more and more widely used in high voltage DC transmission system and high power motor drive system. It is a major topological structure for high power AC-DC converter. Due to the large module number, the complex control algorithm, and the high power user’s back ground, the MMC model used for simulation should be as accurate as possible to simulate the details of how MMC works for the dynamic testing of the MMC controller. But so far, there is no sample simulation MMC model which can simulate the switching dynamic process. In this paper, one curve embedded full-bridge MMC modeling method with detailed representation of IGBT characteristics is proposed. This method is based on the switching curve referring and sample circuit calculation, and it is sample for implementation. Based on the simulation comparison test under Matlab/Simulink, the proposed method is proved to be correct.

  15. ADVANCING THE PROCESSING TECHNOLOGIES OF THE DETAILS OF CONSTRUCTION MACHINERY AND EQUIPMENT

    Directory of Open Access Journals (Sweden)

    Burlachenko Oleg Vasil’evich

    2016-03-01

    Full Text Available On the contemporary stage on the development and advancement of processing technologies of machine and equipment details it is necessary to find a complex solution to the problem of their performance characteristics. This solution supposes the development of specific methods providing and advancing some specific index of performance efficiency (often regardless of real coupling state and the creation and implementation of the technologies having complex physical and technical impacts on the contact combination. The novelty of processing methods is determined by all the components of the technological system, each of which has its own novelty or creates the novelty of the system as a whole due to definite non-traditional combination of the known components. The system of improving the existing and creating new methods and technological processes of manufacturing the products is considered. The mechanical, physical and chemical effects on the work surface in case of specific kinematics of tool path and the workpieces during operation, and also the wear of engine cylinders are analyzed. The authors offer a technology of obtaining nonporous hot-stamped powder alloys with higher strength properties of the outer surface and high plastic properties of core. The unity of the processes of power, temperature and other effects on the working surface of details during their manufacture and operation is established.

  16. Saponification reaction system: a detailed mass transfer coefficient determination.

    Science.gov (United States)

    Pečar, Darja; Goršek, Andreja

    2015-01-01

    The saponification of an aromatic ester with an aqueous sodium hydroxide was studied within a heterogeneous reaction medium in order to determine the overall kinetics of the selected system. The extended thermo-kinetic model was developed compared to the previously used simple one. The reaction rate within a heterogeneous liquid-liquid system incorporates a chemical kinetics term as well as mass transfer between both phases. Chemical rate constant was obtained from experiments within a homogeneous medium, whilst the mass-transfer coefficient was determined separately. The measured thermal profiles were then the bases for determining the overall reaction-rate. This study presents the development of an extended kinetic model for considering mass transfer regarding the saponification of ethyl benzoate with sodium hydroxide within a heterogeneous reaction medium. The time-dependences are presented for the mass transfer coefficient and the interfacial areas at different heterogeneous stages and temperatures. The results indicated an important role of reliable kinetic model, as significant difference in k(L)a product was obtained with extended and simple approach.

  17. Understanding brains: details, intuition, and big data.

    Science.gov (United States)

    Marder, Eve

    2015-05-01

    Understanding how the brain works requires a delicate balance between the appreciation of the importance of a multitude of biological details and the ability to see beyond those details to general principles. As technological innovations vastly increase the amount of data we collect, the importance of intuition into how to analyze and treat these data may, paradoxically, become more important.

  18. Understanding Brains: Details, Intuition, and Big Data

    OpenAIRE

    Marder, Eve

    2015-01-01

    Understanding how the brain works requires a delicate balance between the appreciation of the importance of a multitude of biological details and the ability to see beyond those details to general principles. As technological innovations vastly increase the amount of data we collect, the importance of intuition into how to analyze and treat these data may, paradoxically, become more important.

  19. Understanding brains: details, intuition, and big data.

    Directory of Open Access Journals (Sweden)

    Eve Marder

    2015-05-01

    Full Text Available Understanding how the brain works requires a delicate balance between the appreciation of the importance of a multitude of biological details and the ability to see beyond those details to general principles. As technological innovations vastly increase the amount of data we collect, the importance of intuition into how to analyze and treat these data may, paradoxically, become more important.

  20. Detailed and exhaustive study of the authentication of European virgin olive oils by SEXIA expert system

    Directory of Open Access Journals (Sweden)

    Aparicio, R.

    1994-08-01

    Full Text Available The authentication of extra virgin olive oils from different regions of Spain, Italy and Portugal, by means of their fatty acids, alcohols, sterols, methyl sterols and hydrocarbons content, has been investigated. Multivariate statistical methods and Evidence's Theory were applied. The comparative study shows greater predictive ability using this theory than the traditional statistical methods or expert systems that do not implement the possibility theory. A detailed and exhaustive study of Italian (Tuscany and Basilicata, Portuguese and Spanish virgin olive oils has been made. Geographically coloured maps of the studied regions are shown to strengthen the numerical results.

    Se ha estudiado la autentificación de aceites de oliva virgen de diferentes regiones de España, Italia y Portugal, por su contenido en ácidos grasos, alcoholes, esteroles, metil esteroles e hidrocarburos. Se aplicaron métodos estadísticos multivariantes junto a la Teoría de la Evidencia. El estudio mostró una mejora en la capacidad predictiva utilizando esta teoría frente a otros métodos o sistemas expertos que no implementan la teoría de la posibilidad. Se ha realizado un estudio detallado y exhaustivo con aceites de oliva virgen italianos (Toscana y Basilicata, portugueses y españoles. Los resultados numéricos se muestran sobre mapas geográficos de las diferentes regiones estudiadas.

  1. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  2. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  3. Updates of the fire protection system of the Juzbado Nuclear Fuel Fabrication Plant; Actualizaciones del Sistema de Proteccion Contra Incendios de la Fabrica de Combustible Nuclear de Juzbado

    Energy Technology Data Exchange (ETDEWEB)

    Dorado, P.; Palomo, J. J.; Romano, A.

    2015-07-01

    The Juzbado Nuclear Fuel Fabrication Plant fire protection system is one of the most important safety system of the plant. Every year, a large part of the annual investment is employed to improve this system, to update its technology, in order to improve detection and extinction capability to minimize fire risk. Over the last few years, several improvement projects have been carried out that focused on fire detection technology update and on optimization of local detectors integration with a centralized control system, as well as on an advanced public address system, which used clear and unambiguous messages improving personnel response to a plant evacuation. Planned projects and those, which are currently under development, focus on improving passive fire protection means as well as fire protection of key emergency response equipment s such as emergency diesel generators and fire extinguishing bombs. (Author)

  4. 46 CFR 167.45-45 - Carbon dioxide fire-extinguishing system requirements.

    Science.gov (United States)

    2010-10-01

    ... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45... school ship propelled by internal combustion engines, the quantity of carbon dioxide required may be... arrangement of the piping shall be such as to give a general and fairly uniform distribution over the entire...

  5. 76 FR 10482 - Special Conditions: Boeing Model 787-8 Airplane; Overhead Flightcrew-Rest Compartment Occupiable...

    Science.gov (United States)

    2011-02-25

    ... out. (b) For a manual, hand-held extinguishing system (designed as the sole means to fight a fire or..., except that Sec. 25.1309 remains at Amendment 25- 117 for cargo-fire protection systems. If the... to two flight crewmembers trained in the evacuation, fire fighting, and depressurization procedures...

  6. Air barrier details: How effective are they

    Energy Technology Data Exchange (ETDEWEB)

    A project was initiated to measure the air leakage through three typical details in wood frame walls: the header joist, electric outlets, and window openings. Three construction methods were tested: the poly approach, where a sealed internal polyethylene sheet and caulking provide the air barrier; an external air barrier approach using a continuous vapor permeable membrane sandwiched between two layers of external wall sheathing; and the airtight drywall approach (ADA), where the interior gypsum board finish along with framing and gaskets are the air barrier. Twelve sample panels using each of the three details were built using each of the construction approaches. A traditional wood-frame wall construction detail, with no effort made to create a continuous air barrier, was also built and tested for comparison. The samples were put in a test chamber so that air pressures could create infiltration or exfiltration through the panel under loads similar to those due to wind action. Measurements were made at several stages during construction of each sample to see the effect of different components on the air leakage. Overall, all but the traditional samples and the ADA electrical outlet panel exceeded the current tightness standards for glass and aluminum curtain walls. All three approaches could meet the airtightness standards of the R-2000 program. The total air leakage calculated for each approach is under 20% of that in traditional construction. Of the details tested, window detailing offers the greatest potential for increasing overall airtightness compared to traditional methods. 1 ref., 2 figs., 1 tab.

  7. Nuclear Weak Rates and Detailed Balance in Stellar Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Misch, G. Wendell, E-mail: wendell@sjtu.edu, E-mail: wendell.misch@gmail.com [Department of Physics and Astronomy, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 200240 (China)

    2017-07-20

    Detailed balance is often invoked in discussions of nuclear weak transitions in astrophysical environments. Satisfaction of detailed balance is rightly touted as a virtue of some methods of computing nuclear transition strengths, but I argue that it need not necessarily be strictly obeyed in astrophysical environments, especially when the environment is far from weak equilibrium. I present the results of shell model calculations of nuclear weak strengths in both charged-current and neutral-current channels at astrophysical temperatures, finding some violation of detailed balance. I show that a slight modification of the technique to strictly obey detailed balance has little effect on the reaction rates associated with these strengths under most conditions, though at high temperature the modified technique in fact misses some important strength. I comment on the relationship between detailed balance and weak equilibrium in astrophysical conditions.

  8. Detailed Pictures of Multiple Asteroid Systems in the Main-Belt

    Science.gov (United States)

    Marchis, F.; Emery, J. P.; Enriquez, J. E.; Descamps, P.; Berthier, J.; Vachier, F.; Durech, J.

    2011-12-01

    Since their discovery less than 10 years ago, ~200 known multiple asteroid systems have been studied with a combination of observing techniques, including adaptive optics, lightcurve photometry, and mid-infrared spectrophotometry. Those observations show that ~15 large (D>100km) asteroids that are known to possess km-sized satellite(s) (22 Kalliope, 45 Eugenia, 87 Sylvia, 93 Minerva, 216 Kleopatra, ...) share common orbital characteristics, implying a common formation scenario: e.g. catastrophic disruption or ejection after an oblique impact. More than 70 smaller (10-15km) binary asteroid systems have been detected through anomalies in their lightcurves and are believed to have formed by fission due to the YORP effect. By comparison with meteorite analog densities, mid-IR data reveal that these systems have a significant porosity (larger than 30%) implying a rubble-pile interior. We will review these key results and discuss their implications for the interior of asteroids in the light of recent space mission results. Future explorations using new ground-based facilities and space mission concepts will be also discussed. This work is supported by the NSF grant AAG-0807468 and NASA grant NNX11AD62G

  9. Role of the Dopaminergic System in the Acquisition, Expression and Reinstatement of MDMA-Induced Conditioned Place Preference in Adolescent Mice

    Science.gov (United States)

    Vidal-Infer, Antonio; Roger-Sánchez, Concepción; Daza-Losada, Manuel; Aguilar, María A.; Miñarro, José; Rodríguez-Arias, Marta

    2012-01-01

    Background The rewarding effects of 3,4-methylenedioxy-metamphetamine (MDMA) have been demonstrated in conditioned place preference (CPP) procedures, but the involvement of the dopaminergic system in MDMA-induced CPP and reinstatement is poorly understood. Methodology/Principal Findings In this study, the effects of the DA D1 antagonist SCH 23390 (0.125 and 0.250 mg/kg), the DA D2 antagonist Haloperidol (0.1 and 0.2 mg/kg), the D2 antagonist Raclopride (0.3 and 0.6 mg/kg) and the dopamine release inhibitor CGS 10746B (3 and 10 mg/kg) on the acquisition, expression and reinstatement of a CPP induced by 10 mg/kg of MDMA were evaluated in adolescent mice. As expected, MDMA significantly increased the time spent in the drug-paired compartment during the post-conditioning (Post-C) test, and a priming dose of 5 mg/kg reinstated the extinguished preference. The higher doses of Haloperidol, Raclopride and CGS 10746B and both doses of SCH 23390 blocked acquisition of the MDMA-induced CPP. However, only Haloperidol blocked expression of the CPP. Reinstatement of the extinguished preference was not affected by any of the drugs studied. Analysis of brain monoamines revealed that the blockade of CPP acquisition was accompanied by an increase in DA concentration in the striatum, with a concomitant decrease in DOPAC and HVA levels. Administration of haloperidol during the Post-C test produced increases in striatal serotonin, DOPAC and HVA concentrations. In mice treated with the higher doses of haloperidol and CGS an increase in SERT concentration in the striatum was detected during acquisition of the CPP, but no changes in DAT were observed. Conclusions/Significance These results demonstrate that, in adolescent mice, the dopaminergic system is involved in the acquisition and expression of MDMA-induced CPP, but not in its reinstatement. PMID:22916213

  10. Detailed balance and reciprocity in solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Kirchartz, Thomas; Rau, Uwe [IEF5-Photovoltaik, Forschungszentrum Juelich, 52425 Juelich (Germany)

    2008-12-15

    The limiting efficiency of photovoltaic devices follows from the detailed balance of absorption and emission of a diode according to the Shockley-Queisser theory. However, the principle of detailed balance has more implications for the understanding of photovoltaic devices than only defining the efficiency limit. We show how reciprocity relations between carrier collection and dark carrier injection, between electroluminescence emission and photovoltaic quantum efficiency and between open circuit voltage and light emitting diode quantum efficiency all follow from the principle of detailed balance. We also discuss the validity range of the Shockley-Queisser limit and the reciprocity relations. Discussing the validity of the reciprocity relations helps to deepen the understanding of photovoltaic devices and allows us to identify interrelationships between the superposition principle, the diode ideality and the reciprocity relations. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. A detailed BWR recirculation loop model for RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Araiza-Martínez, Enrique, E-mail: enrique.araiza@inin.gob.mx; Ortiz-Villafuerte, Javier, E-mail: javier.ortiz@inin.gob.mx; Castillo-Durán, Rogelio, E-mail: rogelio.castillo@inin.gob.mx

    2017-01-15

    Highlights: • A new detailed BWR recirculation loop model was developed for RELAP. • All jet pumps, risers, manifold, suction and control valves, and recirculation pump are modeled. • Model is tested against data from partial blockage of two jet pumps. • For practical applications, simulation results showed good agreement with available data. - Abstract: A new detailed geometric model of the whole recirculation loop of a BWR has been developed for the code RELAP. This detailed model includes the 10 jet pumps, 5 risers, manifold, suction and control valves, and the recirculation pump, per recirculation loop. The model is tested against data from an event of partial blockage at the entrance nozzle of one jet pump in both recirculation loops. For practical applications, simulation results showed good agreement with data. Then, values of parameters considered as figure of merit (reactor power, dome pressure, core flow, among others) for this event are compared against those from the common 1 jet pump per loop model. The results show that new detailed model led to a closer prediction of the reported power change. The detailed recirculation loop model can provide more reliable boundary condition data to a CFD models for studies of, for example, flow induced vibration, wear, and crack initiation.

  12. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    International Nuclear Information System (INIS)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner

    2003-01-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  13. Sodium fire studies in France. Safety experiments applied to fast reactors

    International Nuclear Information System (INIS)

    Fruchard, Y.; Colome, J.; Malet, J.C.; Berlin, M.; Duverger de Cuy, G.; Justin, J.; Duco, J.

    1976-01-01

    In fast reactors, the risk of sodium fires must be analyzed in detail and the consequences of an accidental fire must be known precisely. Beyond the search for prevention and detection means, techniques must be developed to set up a limit to damages created by an accidental fire: extinguishing, aerosol confinement, protection of the reactor structures. The program developed by the Nuclear Safety Department of the Commissariat a l'Energie Atomique to solve these various problems is described. The main results and their applications to the Super-Phenix reactor are presented [fr

  14. 42 CFR 401.118 - Deletion of identifying details.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Deletion of identifying details. 401.118 Section 401.118 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Deletion of identifying details. When CMS publishes or otherwise makes available an opinion or order...

  15. Detailed profile of m=2 islands with TVTS on JFT-2M

    International Nuclear Information System (INIS)

    Yamauchi, T.; Grek, B.; Hoshino, K.; Le Blanc, B.; Johnson, D.; Felt, J.; Shiina, T.; Kurita, G.; Ishige, Y.; Kozawa, H.

    1996-01-01

    The detailed electron temperature profile (spatial resolution: 0.86 cm) of a low density JFT-2M plasma is measured with the TV Thomson scattering system (TVTS). Flat profiles showing the electron temperature shapes of m=2/n=1 islands are presented, which are in contrast to that without islands. On the other hand, the m=2/n=1 islands are effectively suppressed with local ECRH heating. (orig.)

  16. Detailed characterization of welding fumes in personal exposure samples

    International Nuclear Information System (INIS)

    Quémerais, B; Mino, James; Amin, M R; Golshahi, H; Izadi, H

    2015-01-01

    The objective of the project was to develop a method allowing for detailed characterization of welding particles including particle number concentration, size distribution, surface chemistry and chemical composition of individual particles, as well as metal concentration of various welding fumes in personal exposure samples using regular sampling equipment. A sample strategy was developed to evaluate the variation of the collection methods on mass concentration. Samples were collected with various samplers and filters at two different locations using our collection system. The first location was using a robotic welding system while the second was manual welding. Collected samples were analysed for mass concentration using gravimetryand metal concentration using ICP/OES. More advanced analysis was performed on selected filters using X-Ray Photoelectron Spectroscopy to determine surface composition of the particles, and X-Ray Diffraction to determine chemical composition of the fumes. Results showed that the robotic system had a lot of variation in space when the collection system was located close to the weld. Collection efficiency was found to be quite variable depending upon the type of filter. As well, metal concentrations in blank filters were dependent upon the type of filter with MCE presenting with the highest blank values. Results obtained with the XRD and XPS systems showed that it was possible to analyse a small of powdered welding fume sample but results on filters were not conclusive. (paper)

  17. Can quantum coherent solar cells break detailed balance?

    International Nuclear Information System (INIS)

    Kirk, Alexander P.

    2015-01-01

    Carefully engineered coherent quantum states have been proposed as a design attribute that is hypothesized to enable solar photovoltaic cells to break the detailed balance (or radiative) limit of power conversion efficiency by possibly causing radiative recombination to be suppressed. However, in full compliance with the principles of statistical mechanics and the laws of thermodynamics, specially prepared coherent quantum states do not allow a solar photovoltaic cell—a quantum threshold energy conversion device—to exceed the detailed balance limit of power conversion efficiency. At the condition given by steady-state open circuit operation with zero nonradiative recombination, the photon absorption rate (or carrier photogeneration rate) must balance the photon emission rate (or carrier radiative recombination rate) thus ensuring that detailed balance prevails. Quantum state transitions, entropy-generating hot carrier relaxation, and photon absorption and emission rate balancing are employed holistically and self-consistently along with calculations of current density, voltage, and power conversion efficiency to explain why detailed balance may not be violated in solar photovoltaic cells

  18. Acceleration of Convergence to Equilibrium in Markov Chains by Breaking Detailed Balance

    Science.gov (United States)

    Kaiser, Marcus; Jack, Robert L.; Zimmer, Johannes

    2017-07-01

    We analyse and interpret the effects of breaking detailed balance on the convergence to equilibrium of conservative interacting particle systems and their hydrodynamic scaling limits. For finite systems of interacting particles, we review existing results showing that irreversible processes converge faster to their steady state than reversible ones. We show how this behaviour appears in the hydrodynamic limit of such processes, as described by macroscopic fluctuation theory, and we provide a quantitative expression for the acceleration of convergence in this setting. We give a geometrical interpretation of this acceleration, in terms of currents that are antisymmetric under time-reversal and orthogonal to the free energy gradient, which act to drive the system away from states where (reversible) gradient-descent dynamics result in slow convergence to equilibrium.

  19. Neuroinflammation: the devil is in the details.

    Science.gov (United States)

    DiSabato, Damon J; Quan, Ning; Godbout, Jonathan P

    2016-10-01

    There is significant interest in understanding inflammatory responses within the brain and spinal cord. Inflammatory responses that are centralized within the brain and spinal cord are generally referred to as 'neuroinflammatory'. Aspects of neuroinflammation vary within the context of disease, injury, infection, or stress. The context, course, and duration of these inflammatory responses are all critical aspects in the understanding of these processes and their corresponding physiological, biochemical, and behavioral consequences. Microglia, innate immune cells of the CNS, play key roles in mediating these neuroinflammatory responses. Because the connotation of neuroinflammation is inherently negative and maladaptive, the majority of research focus is on the pathological aspects of neuroinflammation. There are, however, several degrees of neuroinflammatory responses, some of which are positive. In many circumstances including CNS injury, there is a balance of inflammatory and intrinsic repair processes that influences functional recovery. In addition, there are several other examples where communication between the brain and immune system involves neuroinflammatory processes that are beneficial and adaptive. The purpose of this review is to distinguish different variations of neuroinflammation in a context-specific manner and detail both positive and negative aspects of neuroinflammatory processes. In this review, we will use brain and spinal cord injury, stress, aging, and other inflammatory events to illustrate the potential harm and benefits inherent to neuroinflammation. Context, course, and duration of the inflammation are highly important to the interpretation of these events, and we aim to provide insight into this by detailing several commonly studied insults. This article is part of the 60th anniversary supplemental issue. © 2016 International Society for Neurochemistry.

  20. The Clouds distributed operating system - Functional description, implementation details and related work

    Science.gov (United States)

    Dasgupta, Partha; Leblanc, Richard J., Jr.; Appelbe, William F.

    1988-01-01

    Clouds is an operating system in a novel class of distributed operating systems providing the integration, reliability, and structure that makes a distributed system usable. Clouds is designed to run on a set of general purpose computers that are connected via a medium-of-high speed local area network. The system structuring paradigm chosen for the Clouds operating system, after substantial research, is an object/thread model. All instances of services, programs and data in Clouds are encapsulated in objects. The concept of persistent objects does away with the need for file systems, and replaces it with a more powerful concept, namely the object system. The facilities in Clouds include integration of resources through location transparency; support for various types of atomic operations, including conventional transactions; advanced support for achieving fault tolerance; and provisions for dynamic reconfiguration.

  1. Assessment of the underground construction details of a road pavement using GPR antenna systems with different frequencies

    Science.gov (United States)

    Alani, Amir M.; Tosti, Fabio; Bianchini Ciampoli, Luca; Benedetto, Francesco; Benedetto, Andrea

    2017-04-01

    The assessment of the underground construction details of a road infrastructure is a problem of great concern in highway engineering. The case becomes complicated especially when damages reoccur after carrying out remedial surface maintenance and repair works over the life cycle of the infrastructure. The challenge will be exacerbated at the presence of underground watercourses, such that the geotechnical stability of the entire road structure could be threatened. In this respect, ground-penetrating radar (GPR) has been recognised and accepted as one of the most effective non-destructive testing (NDT) techniques that could be employed in identifying the cause/s of such problems. The recent advancements and developments made in the field of GPR hardware as well as the current level of understanding of the applications and processing techniques of the GPR data have immensely added to the reliability in the utilisation of this tool in variety of subsurface investigation projects. In view of this, the work presented in here focuses on the assessment of the underground construction details of a road pavement using different frequency GPR antenna systems. In addition to this, the possible presence and location of an underground watercourse was investigated in this work. The existence of the latter problem was perceived due to reoccurrence of longitudinal and traversal road surface cracking as well as subsidence at a particular location of the road. Reoccurrence of this damage was interpreted and related to the possible existence of an underground watercourse. The original design and the construction of the road were as such to prevent this movement. Therefore it seemed necessary to perform a GPR survey to investigate and confirm the underground construction details of the road. To this purpose, the identified area was surveyed using high to low frequency antennas with 2000 MHz, 900 MHz, 600 MHz and 200 MHz central frequencies of investigation. Scans were performed at 1m

  2. Detailed description of an SSAC at the facility level for light water moderated (off-load refueled) power reactor facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-03-01

    This report is intended to provide the technical details of an effective State Systems of Accounting for and Control of Nuclear Material (SSAC) which Member States may use, if they wish, to establish and maintain their SSACs. It is expected that systems designed along the lines described would be effective in meeting the objectives of both national and international systems for nuclear material accounting and control. This document accordingly provides a detailed description of a system for the accounting for and control of nuclear material in an off-load refueled light water moderated power reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  3. Results of Detailed Hydrologic Characterization Tests - Fiscal Year 2000

    International Nuclear Information System (INIS)

    Spane, Frank A; Thorne, Paul D; Newcomer, Darrell R

    2001-01-01

    This report provides the results of detailed hydrologic characterization tests conducted within eleven Hanford Site wells during fiscal year 2000. Detailed characterization tests performed included groundwater-flow characterization; barometric response evaluation; slug tests; single-well tracer tests; constant-rate pumping tests; and in-well, vertical flow tests. Hydraulic property estimates obtained from the detailed hydrologic tests include transmissivity; hydraulic conductivity; specific yield; effective porosity; in-well, lateral flow velocity; aquifer-flow velocity; vertical distribution of hydraulic conductivity (within the well-screen section); and in-well, vertical flow velocity. In addition, local groundwater-flow characteristics (i.e., hydraulic gradient and flow direction) were determined for four sites where detailed well testing was performed

  4. 49 CFR 7.6 - Deletion of identifying detail.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Deletion of identifying detail. 7.6 Section 7.6... To Be Made Public by DOT § 7.6 Deletion of identifying detail. Whenever it is determined to be... the deletion will accompany the record published or made available for inspection. ...

  5. 46 CFR 107.231 - Inspection for certification.

    Science.gov (United States)

    2010-10-01

    ... effectively carry out abandonment and fire fighting procedures. Fire Fighting Equipment (h) Each hand portable... accordance with § 107.235(a). (i) Each fixed fire-extinguishing system is inspected, and serviced if required, in accordance with § 107.235(b). (j) Each fire main system meets the testing requirements in § 107...

  6. Preference for Well-Balanced Saliency in Details Cropped from Photographs

    Science.gov (United States)

    Abeln, Jonas; Fresz, Leonie; Amirshahi, Seyed Ali; McManus, I. Chris; Koch, Michael; Kreysa, Helene; Redies, Christoph

    2016-01-01

    Photographic cropping is the act of selecting part of a photograph to enhance its aesthetic appearance or visual impact. It is common practice with both professional (expert) and amateur (non-expert) photographers. In a psychometric study, McManus et al. (2011b) showed that participants cropped photographs confidently and reliably. Experts tended to select details from a wider range of positions than non-experts, but other croppers did not generally prefer details that were selected by experts. It remained unclear, however, on what grounds participants selected particular details from a photograph while avoiding other details. One of the factors contributing to cropping decision may be visual saliency. Indeed, various saliency-based computer algorithms are available for the automatic cropping of photographs. However, careful experimental studies on the relation between saliency and cropping are lacking to date. In the present study, we re-analyzed the data from the studies by McManus et al. (2011a,b), focusing on statistical image properties. We calculated saliency-based measures for details selected and details avoided during cropping. As expected, we found that selected details contain regions of higher saliency than avoided details on average. Moreover, the saliency center-of-mass was closer to the geometrical center in selected details than in avoided details. Results were confirmed in an eye tracking study with the same dataset of images. Interestingly, the observed regularities in cropping behavior were less pronounced for experts than for non-experts. In summary, our results suggest that, during cropping, participants tend to select salient regions and place them in an image composition that is well-balanced with respect to the distribution of saliency. Our study contributes to the knowledge of perceptual bottom-up features that are germane to aesthetic decisions in photography and their variability in non-experts and experts. PMID:26793086

  7. How should low-contrast detail detectability be measured in fluoroscopy?

    International Nuclear Information System (INIS)

    Tapiovaara, Markku J.; Sandborg, Michael

    2004-01-01

    The relationship and precision of four methods for measuring the low-contrast detail detectability in fluoroscopic imaging were studied. These included the physical measurement of the accumulation rate of the square of the signal-to-noise ratio (SNR rate 2 ), two-alternative forced-choice (2-AFC) experiments, sixteen-alternative forced-choice (16-AFC) experiments and subjective determination of the threshold contrast. The precision and sensitivity of the threshold contrast measurement were seen to be modest in the constancy testing of fluoroscopic equipment: only large changes in system performance could be reliably detected by that method. The measurement of the SNR rate 2 is suggested instead. The relationship between the results of the various methods were studied, and it was found that human performance can be related to SNR rate 2 by introducing the concept of the effective image information integration time (t eff ). When measured for an unlimited observation time, it depicts the saturation of human performance in detecting a static low-contrast detail in dynamic image noise. Here, t eff was found to be about 0.6 s in 2-AFC tests and 0.3 s in 16-AFC tests

  8. Detailed inelastic analysis of an LMFBR pipeline

    International Nuclear Information System (INIS)

    Hibbitt, H.D.; Leung, E.K.; Ohalla, A.K.

    1982-01-01

    The paper describes detailed inelastic analyses of a large diameter, thin walled pipeline configuration typical of liquid metal cooled reactor primary piping, subject to thermal shock, with intermediate periods of creep hold time. Three such analyses are compared. Two of these analyses are performed with recently developed elements based on a combination of Fourier and polynomial interpolation to describe the deformation of the pipe. One of these two analyses includes continuous deformation of the pipe wall between each elbow and the adjacent straight pipe segments, while the other neglects such ''end effects'' on the elbow deformation. The third analysis is based on a modified axi-symmetric shell element for modeling the elbows (neglecting and effects). The results thus provide an assessment of the relative cost and importance of including consideration of end effects in modeling a realistic piping system, as well as providing a similar comparison between the two basic deforming section pipe models (Fourier/polynomial versus modified axi-symmetric shells)

  9. 46 CFR 76.50-90 - Vessels contracted for prior to November 19, 1952.

    Science.gov (United States)

    2010-10-01

    ... by table 76.50-10(a). In such cases, minor modifications may be made to the same standards as the... VESSELS FIRE PROTECTION EQUIPMENT Hand Portable Fire Extinguishers and Semiportable Fire Extinguishing...

  10. 41 CFR 102-75.1225 - What details are provided in the “Notice of Availability”?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What details are... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL... information, and a date by which an interested Federal agency must respond in writing to indicate a definite...

  11. Spontaneous ignition of natural uranium in Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1989-01-01

    At P.M. 7:23, May 30, 1989, a fire alarm functioned in the uranium enrichment laboratory building, and immediately investigation was carried out, as the result, smoke was confirmed in the nuclear fuel storage. In the nuclear fuel storage, there were five plastic bottles containing natural uranium chips, and smoke arose from three of them. Immediately fire fighting was carried out with powder extinguishers and others, the uranium chips which were regarded as the heat generating source were moved into stainless steel cans, and air was cut off with extinguishing sand, as the result, around P.M. 9:50, heat generation ceased. At present the detailed cause is being investigated, but it is considered that the uranium chips contained in plastic bottles reacted with air by some cause, and generated heat in the form of spontaneous ignition, as the result, the plastic bottles and the vinyl sheets placed under them smoked. The stack dust monitor in the uranium enrichment laboratory building showed the normal value, and there was not the effect to surrounding environment. The workers who did fire fighting with whole face masks were not affected by smoke. (K.I.)

  12. Detailed description of an SSAC at the facility level for mixed oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-09-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in a mixed oxide fuel fabrication facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  13. Post Entitlement Management Information - Detail Database

    Data.gov (United States)

    Social Security Administration — Contains data that supports the detailed and aggregate receipt, pending and clearance data, as well as other strategic and tactical MI for many Title II and Title...

  14. Study on application of radiation and radioisotopes -Development of the radioisotope production facilities for the HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Bok; Woo, Jong Sub; Kang, Byung Woi; Baek, Sam Tae; Jeong, Un Soo; Park, Yong Chul; Jeon, Young Keon; Chang, Chun Ik; Lee, Bong Jae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-08-01

    Development and construction of the lead hot cell for radioisotope production and related facility. 1. Fabrication and installation of the lead H/C system. 2. Development and installation of the hydraulic transfer system. 3. Development of the radiation monitoring system. 4. Fabrication and installation of the fire extinguishing system in the H/C. 5. Fabrication and installation of the fume hood. 4 tabs.,10 figs. (Author).

  15. End region detailing of pretensioned concrete bridge girders : [summary].

    Science.gov (United States)

    2013-03-01

    Introduction of the Florida-I Beam (FIB) in 2009 renewed interest in prestressed concrete beam design, especially end region details. In this study, University of Florida researchers examined construction detailing at the FIB end region.

  16. Details and justifications for the MAP concept specification for acceleration above 63 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J. Scott [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-02-28

    The Muon Accelerator Program (MAP) requires a concept specification for each of the accelerator systems. The Muon accelerators will bring the beam energy from a total energy of 63 GeV to the maximum energy that will fit on the Fermilab site. Justifications and supporting references are included, providing more detail than will appear in the concept specification itself.

  17. A Content Analysis of Officer Perceptions of Detailing.

    Science.gov (United States)

    1981-03-01

    answer was "No Way"! Told me needs of service were in Philippine Island CNSG WESTPAC as OPS, three year tour. I wrote letter saying O.K. Was detailed as...off to them as it has to be least preferred of all tasks...personnel detailer. 2 I regret the tardiness of this reply - New Zealand is a long way

  18. Detailed free span assessment for Mexilhao flow lines

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Antonio; Franco, Luciano; Eigbe, Uwa; BomfimSilva, Carlos [INTECSEA, Houston, TX (United States); Escudero, Carlos [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The subsea gas production system of Mexilhao Field SPS-35, Santos Basin, offshore Brazil, is composed basically of two rigid 12.75 inches production flow lines approximately 21 km long installed in a fairly rough seabed. During the basic design, the free span assessment was performed considering the maximum allowable free span length determined by the response model proposed by DNV-RP-F105. This approach resulted in a large number of predicted free span requiring corrections, leading to a higher capital cost for the project. In this sense, a detailed free span VIV fatigue assessment was proposed, considering multi-spans and multi-mode effects and also the post lay survey data. The assessment followed the DNV-RP-F105 recommendations for multi-spans and multi-mode effects, using Finite Element Analysis to determine the natural frequencies, mode shapes and corresponding stresses associated with the mode shapes. The assessment was performed in three stages, the first during the detailed design as part of the bottom roughness analysis using the expected residual pipelay tension. The second stage was performed after pipelay, considering the post-lay survey data, where the actual requirements for span correction were determined. Actual pipelay tension was used and seabed soil stiffness adjusted in the model to match the as-laid pipeline profile obtained from the survey data. The first and second stage assessments are seamlessly automated to speed up the evaluation process and allow for quick response in the field, which was important to keep the construction vessel time minimized. The third stage was performed once the corrections of the spans were made and the purpose was to confirm that the new pipeline configuration along the supported spans had sufficient fatigue life for the temporary and operational phases. For the assessment of all three stages, the probability of occurrence and directionality of the near bottom current was considered to improve prediction of the

  19. Family physicians' perceptions of academic detailing: a quantitative and qualitative study

    Directory of Open Access Journals (Sweden)

    O'Connor Nicolette

    2007-10-01

    Full Text Available Abstract Background The efficacy of academic detailing in changing physicians' knowledge and practice has been the subject of many primary research publications and systematic reviews. However, there is little written about the features of academic detailing that physicians find valuable or that affect their use of it. The goal of our project was to explore family physicians' (FPs perceptions of academic detailing and the factors that affect their use of it. Methods We used 2 methods to collect data, a questionnaire and semi-structured telephone interviews. We mailed questionnaires to all FPs in the Dalhousie Office of Continuing Medical Education database and analyzed responses of non-users and users of academic detailing. After a preliminary analysis of questionnaire data, we conducted semi-structured interviews with 7 FPs who did not use academic detailing and 17 who did use it. Results Overall response rate to the questionnaire was 33% (289/869. Response rate of non-users of academic detailing was 15% (60/393, of users was 48% (229/476. The 3 factors that most encouraged use of academic detailing were the topics selected, the evidence-based approach adopted, and the handout material. The 3 factors that most discouraged the use of academic detailing were spending office time doing CME, scheduling time to see the academic detailer, and having CME provided by a non-physician. Users of academic detailing rated it as being more valuable than other forms of CME. Generally, interview data confirmed questionnaire data with the exception that interview informants did not view having CME provided by a non-physician as a barrier. Interview informants mentioned that the evidence-based approach adopted by academic detailing had led them to more critically evaluate information from other CME programs, pharmaceutical representatives, and journal articles, but not advice from specialists. Conclusion Users of academic detailing highly value its educational

  20. Temperature Measurements of Dense Plasmas by Detailed Balance

    International Nuclear Information System (INIS)

    Holl, A; Redmer, R; Ropke, G; Reinholz, H; Thiele, R; Fortmann, C; Forster, E; Cao, L; Tschentscher, T; Toleikis, S; Glenzer, S H

    2006-01-01

    Plasmas at high electron densities of n e = 10 20 - 10 26 cm -3 and moderate temperatures T e = 1 - 20 eV are important for laboratory astrophysics, high energy density science and inertial confinement fusion. These plasmas are usually referred to as Warm Dense Matter (WDM) and are characterized by a coupling parameter of Λ ∼> 1 where correlations become important. The characterization of such plasmas is still a challenging task due to the lack of direct measurement techniques for temperatures and densities. They propose to measure the Thomson scattering spectrum of vacuum-UV radiation off density fluctuations in the plasma. Collective Thomson scattering provides accurate data for the electron temperature applying first principles. Further, this method takes advantage of the spectral asymmetry resulting from detailed balance and is independent of collisional effects in these dense systems

  1. A 24 GHz Waveguide based Radar System using an Advanced Algorithm for I/Q Offset Cancelation

    Directory of Open Access Journals (Sweden)

    C. Will

    2017-10-01

    Full Text Available Precise position measurement with micrometer accuracy plays an important role in modern industrial applications. Herewith, a guided wave Six-Port interferometric radar system is presented. Due to limited matching and discontinuities in the radio frequency part of the system, the designers have to deal with DC offsets. The offset voltages in the baseband lead to worse relative modulation dynamics relating to the full scale range of the analog-to-digital converters and thus, considerably degrade the system performance. While common cancelation techniques try to estimate and extinguish the DC offsets directly, the proposed radar system is satisfied with equalizing both DC offsets for each of the two differential baseband signal pairs. Since the complex representation of the baseband signals is utilized for a subsequent arctangent demodulation, the proposed offset equalization implicates a centering of the in-phase and quadrature (I/Q components of the received signal, which is sufficient to simplify the demodulation and improve the phase accuracy. Therefore, a standard Six-Port radar system is extended and a variable phase shifter plus variable attenuators are inserted at different positions. An intelligent algorithm adjusts these configurable components to achieve optimal I/Q offset cancelation.

  2. Detail, Facture, and Colour in the Architecture of Polish Single-Family Houses after 1989

    Science.gov (United States)

    Sztafrowski, Marek

    2017-10-01

    The article presents single-family houses architecture transformations since 1989, with particularly close attention paid to the significance of detail, facture, and colour. The article presents the architecture as an art of designing and building facilities with both use and aesthetic value, an art of shaping space and building forms. Architectural work should correspond to the intended function, technique, economic and aesthetic requirements, thus shaping all elements of human immediate environment, both inside and outside of the building. Architecture of the building is perceived as form, structure, and function, as well as detail, facture, and colour. Facture and colour are created through materials used for external finishes. The solid of the building is noticed first while looking at the building, then the finishes detail such as colour, facture, and detail. Materials for external finishes are commonly selected for their aesthetic value equally with their technical characteristics. The detail was always a characteristic element of style. However, currently the fashion for details can be observed, the fashion for usage of materials for external finishes and inter-connected with that colour and facture. The architecture of Polish single-family houses underwent considerable metamorphosis after system change of 1989 - from destitute in form, devoid in detail and colour socmodernism, to architecture extremely varied in terms of form, utilised structures, materials, and detail. Hence, appearance of the phenomenon called fashion can be observed in the architecture, understood as constant changeability, seeking novelty, and creation based on opinion-forming centres. The architectural fashion consists of form, function, structure, building materials, detail, facture, and colour trends, e.g. after rejecting socmodernism, steep roofs characteristic for single-family houses trend started. After 1989, initially individual single-family house projects were created; however

  3. DAGAL: Detailed Anatomy of Galaxies

    Science.gov (United States)

    Knapen, Johan H.

    2017-03-01

    The current IAU Symposium is closely connected to the EU-funded network DAGAL (Detailed Anatomy of Galaxies), with the final annual network meeting of DAGAL being at the core of this international symposium. In this short paper, we give an overview of DAGAL, its training activities, and some of the scientific advances that have been made under its umbrella.

  4. Attenuation of saccharin-seeking in rats by orexin/hypocretin receptor 1 antagonist.

    Science.gov (United States)

    Cason, Angie M; Aston-Jones, Gary

    2013-08-01

    The orexin (Orx)/hypocretin system has been implicated in reward-seeking, especially for highly salient food and drug rewards. We recently demonstrated that signaling at the OxR1 receptor is involved in sucrose reinforcement and reinstatement of sucrose-seeking elicited by sucrose-paired cues in food-restricted rats. Because sucrose reinforcement has both a hedonic and caloric component, it remains unknown what aspect of this reward drives its reinforcing value. The present study examined the involvement of the Orx system in operant responding for saccharin, a noncaloric, hedonic (sweet) reward, and in cue-induced reinstatement of extinguished saccharin-seeking in ad libitum-fed vs food-restricted male subjects. Male Sprague Dawley rats were fed ad libitum or food-restricted and trained to self-administer saccharin. We determined the effects of pretreatment with the OxR1 receptor antagonist SB-334867 (SB; 10-30 mg/kg) on fixed ratio (FR) saccharin self-administration and on cue-induced reinstatement of extinguished saccharin-seeking. SB decreased responding and number of reinforcers earned during FR responding for saccharin and decreased cue-induced reinstatement of extinguished saccharin-seeking. All of these effects were obtained similarly in food-restricted and ad libitum-fed rats. These results indicate that signaling at the OxR1 receptor is involved in saccharin reinforcement and reinstatement of saccharin-seeking elicited by saccharin-paired cues regardless of food restriction. These findings lead us to conclude that the Orx system contributes to the motivational effects of hedonic food rewards, independently of caloric value and homeostatic needs.

  5. Detailed Analysis of the Transient Voltage in a JT-60SA PF Coil Circuit

    International Nuclear Information System (INIS)

    Yamauchi, K.; Shimada, K.; Terakado, T.; Matsukawa, M.; Coletti, R.; Lampasi, A.; Gaio, E.; Coletti, A.; Novello, L.

    2013-01-01

    A superconducting coil system is actually complicated by the distributed parameters, e.g. the distributed mutual inductance among turns and the distributed capacitance between adjacent conductors. In this paper, such a complicated system was modeled with a reasonably simplified circuit network with lumped parameters. Then, a detailed circuit analysis was conducted to evaluate the possible voltage transient in the coil circuit. As a result, an appropriate (minimum) snubber capacitance for the Switching Network Unit, which is a fast high voltage generation circuit in JT-60SA, was obtained. (fusion engineering)

  6. Optical versus radiographic magnification for fine-detail skeletal radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Doi, K.; Mall, J.C.

    1974-01-01

    Fine detail radiographic techniques for peripheral skeletal imaging have gained wide clinical acceptance. In this study, the imaging properties and clinical applications of the optical magnification technique, which employs fine-grain industrial film and a large focal spot, have been compared quantitatively and qualitatively with those of three slow screen-film techniques, namely, contact exposure with a large focal spot, 2X radiographic magnification with a 0.3 mm focal spot, and 4X radiographic magnification with a 50 μ focal spot. The modulation transfer functions (MTFs) of the recording systems and focal spots have been obtained and film sensitometry has been performed. Clinical comparisons for patients with metabolic, arthritic, and neoplastic skeletal disorders have been made. The results illustrate the superiority of the optical magnification technique over contact or 2X magnification techniques using slow screen-film systems. If a microfocus tube is used, however, direct radiographic magnification may provide images comparable in resolution, noise, and contrast to those made with the optical magnification technique, and at lower radiation exposure to the patient. (U.S.)

  7. Fire safety of LPG in marine transportation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

    1980-06-01

    This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

  8. Severn Barrage project. Detailed report - V. 5

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Prior to the present programme of work, the effects which a tidal power barrage would have on the region, during both construction and operation, had not been studied in detail. This volume of the Detailed Report therefore represents a significant extension of work into these aspects of the Severn Barrage Project. In the Regional Study, a number of benefits have been identified, some of which may represent net benefits nationally. The economic assessment of both regional and national benefits and costs is presented. The second part of this volume reports on the work done on the Legal Background for the Project. (author).

  9. Mobil's two-agent firetruck

    International Nuclear Information System (INIS)

    Lockwood, N.R.

    1985-01-01

    A unique, efficient fire truck that delivers both dry chemical and foam has been developed by Mobil Oil. It will extinguish three-dimensional fires 100 feet away, at grade or overhead, and spill fires 70 feet wide, 130 feet away. Knockdown, control or extinguishment occurs in less than 20 seconds. The foam water monitor has a reach of 200 feet - straight stream or spray. The truck can use any combination of dry chemical, foam or water and can extinguish tank fires to 120 feet in diameter

  10. Detailed Debunking of Denial

    Science.gov (United States)

    Enting, I. G.; Abraham, J. P.

    2012-12-01

    The disinformation campaign against climate science has been compared to a guerilla war whose tactics undermine the traditional checks and balances of science. One comprehensive approach has to been produce archives of generic responses such as the websites of RealClimate and SkepticalScience. We review our experiences with an alternative approach of detailed responses to a small number of high profile cases. Our particular examples were Professor Ian Plimer and Christopher Monckton, the Third Viscount Monckton of Brenchley, each of whom has been taken seriously by political leaders in our respective countries. We relate our experiences to comparable examples such as John Mashey's analysis of the Wegman report and the formal complaints about Lomborg's "Skeptical Environmentalist" and Durkin's "Great Global Warming Swindle". Our two approaches used contrasting approaches: an on-line video of a lecture vs an evolving compendium of misrepresentations. Additionally our approaches differed in the emphasis. The analysis of Monckton concentrated on the misrepresentation of the science, while the analysis of Plimer concentrated on departures from accepted scientific practice: fabrication of data, misrepresentation of cited sources and unattributed use of the work of others. Benefits of an evolving compendium were the ability to incorporate contributions from members of the public who had identified additional errors and the scope for addressing new aspects as they came to public attention. `Detailed debunking' gives non-specialists a reference point for distinguishing non-science when engaging in public debate.

  11. Planning for protecting power plants must not be just an afterthought

    International Nuclear Information System (INIS)

    Hogg, Bruce

    1991-01-01

    In this paper the Principal Fire and Major Incident Engineer at Nuclear Electric plc looks at fire safety in nuclear power plants, from the application of sophisticated 'state of the art' detection and extinguishment systems to the provision of well-trained firefighting teams. (author)

  12. 30 CFR 57.4560 - Mine entrances.

    Science.gov (United States)

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... escapeways shall be— (a) Provided with a fire suppression system, other than fire extinguishers and water...

  13. PROJECT-ORIENTED RESOURCE MANAGEMENT SYSTEM FOR RESPONDING TO EMERGENCIES IN RURAL AREAS

    Directory of Open Access Journals (Sweden)

    Андрій Іванович ІВАНУСА

    2016-02-01

    Full Text Available Substantiated way to determine the feasibility of the location of rescue units in the conditions of rural areas. Proposed improving the existing methods of using of forces and means to extinguish fires, emergencies, etc., by involving specially trained volunteer rescue brigades, carrying out daily duty at their place of residence. To improve the interaction of rescue units involved in the reaction to emergency situations improved the system of information and communication management of forces and means. Developed the model diagram of the project environment optimal allocation of resources when creating center responding to emergencies in conditions of encirclement turbulent environment of a sphere of civil protection. Developed 3D-model and WBS-structure of the project creation of center responding to emergencies using modern energy saving technologies that will minimize the use of financial resources on the stages of the realization and exploitation of the project.

  14. Detailed Theoretical Characterization of a Transcritical CO2 Direct Expansion Ground Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Parham Eslami-Nejad

    2018-02-01

    Full Text Available A new avenue in modern heat pump technology is related to the use of natural refrigerants such as carbon dioxide (CO2. The use of CO2 in direct expansion ground source heat pumps (DX-GSHP has also gained significant interest as it offers opportunities for cost reduction of the ground loop, albeit some challenges remain in their development, design and use. To address these challenges and to characterize CO2-DX-GSHP performance for water heating applications, a detailed theoretical model and a fully-instrumented test apparatus was developed and built at CanmetENERGY Research Laboratory. The theoretical model was validated against a set of experimental results and adopted to investigate the performance of the system over a wide operating range. Validation results showed that the model predicts the experimental results within the measurement uncertainty. A detailed system performance analysis was also performed using the theoretical model to understand the system behavior and explore the actions required for performance improvement in future installations. The results of the analysis showed that improper design and control of some components, such as the gas cooler and ground heat exchanger can degrade the system performance by up to 25%, and the heat pump heating capacity by 7.5%.

  15. The Memory System Engaged During Acquisition Determines the Effectiveness of Different Extinction Protocols

    OpenAIRE

    Goodman, Jarid; Packard, Mark G.

    2015-01-01

    Previous research indicates that extinction of rodent maze behavior may occur without explicit performance of the previously required response. In latent extinction, confining an animal to a previously rewarded goal location without reinforcement is typically sufficient to produce extinction of maze learning. However, previous studies have not determined whether latent extinction may be successfully employed to extinguish all types of memory acquired in the maze, or whether only specific typ...

  16. Fire safety at home

    Science.gov (United States)

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  17. Effervescent Fine Water Mist Fire Extinguisher for Microgravity Environments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Fire suppression systems provide an essential safety function onboard spacecraft. The transition away from halon-based systems has presented an opportunity for...

  18. Perspective methods of fire and explosion protection of 'Ukrytie' object

    International Nuclear Information System (INIS)

    Zakhmatov, V.D.; Potikha, V.M.; Shkarabura, N.G.

    1999-01-01

    There are 5 atomic power stations in Ukraine-Chernobyl, Zaporozhe, Rivne, Khmelnytsk, Yuzhnoukrainsk. Fire statistics on them: 1993 - 5 fires, 1994 - 2, 1995 - 2, 1996 - 3, 1997-98 no fires. The most valuable unique experience, accumulated in Ukraine, -is extinguishing of different fires, arising in the radioactive zone. There were the following kinds of fires: burning roof of the 4-th bloc; forest fires; fires in cable tunnels; spilled oil in wrecked constructions and buildings. Professional impulse fire-extinguisher is one of the most perspective developments. These fire-extinguishers have high power, range and scale of action. They are universal: able to solve different tasks in extinguishing, to decontaminate, for group and individual light and heat protection, for preventing explosions of dust and gas of up to 50 m 3 volume and in the open space

  19. Basic and detail engineering development of PTAMB

    International Nuclear Information System (INIS)

    Beuter, Oscar; Reibel, Jose A.; Mirad, Andres E.; Furriel, Miguel; Diaz, L.

    2009-01-01

    The purpose of the future Treatment and Conditioning of Medium and Low Activity Solid and Liquid Waste Plant (PTAMB) of the National Atomic Energy Commission (CNEA) will be to put up medium and low activity solid and liquid waste and to verify the quality of the conditioned waste generated in Ezeiza Atomic Center (CAE), Constituyentes Atomic Center (CAC) and other national producers outside CNEA. The PTAMB is a Class I Radioactive Installation (according to Basic Standard AR 10.1.1, Rev. 3 RNA, paragraphs 17 and 22) also called Relevant Installation. The aim of this document is to list the steps that carried out the Projects Department of the National Program of Radioactive Waste Management (PNGRR) to arrive to the realization of the detailed engineering of the plant. The project is in Public Tender stage and the beginning of the construction would be March 2010. Once built, the Plant will process the radioactive waste contained in the conceptual engineering, offering more precise control of these and their compatibility with the new final disposal systems to build. (author)

  20. The E-ELT project: the telescope main structure detailed design study

    Science.gov (United States)

    Marchiori, Gianpietro; Busatta, Andrea; Ghedin, Leonardo; De Lorenzi, Simone

    2012-09-01

    The European Extremely Large Telescope (E-ELT) is the biggest telescope in the world. Within the Detailed Design activities, ESO has awarded EIE GROUP (European Industrial Engineering) a contract for the Design of the Main Structure to the point where the concept of the telescope has been consolidated, from a construction point of view. All the Design activities have been developed in order to create an integrated system in terms of functionality and performance, while the engineering activities have been performed with the aim of obtaining a telescope that can be built, transported, integrated, with a reduced maintainability.

  1. A detailed gravimetric geoid from North America to Eurasia

    Science.gov (United States)

    Vincent, S. F.; Strange, W. E.; Marsh, J. G.

    1972-01-01

    A detailed gravimetric geoid of the United States, North Atlantic, and Eurasia, which was computed from a combination of satellite derived and surface gravity data, is presented. The precision of this detailed geoid is + or - 2 to + or - 3 m in the continents but may be in the range of 5 to 7 m in those areas where data is sparse. Comparisons of the detailed gravimetric geoid with results of Rapp, Fischer, and Rice for the United States, Bomford in Europe, and Heiskanen and Fischer in India are presented. Comparisons are also presented with geoid heights from satellite solutions for geocentric station coordinates in North America, the Caribbean, and Europe.

  2. Current status on detail design and fabrication techniques development of ITER blanket shield block in Korea

    International Nuclear Information System (INIS)

    Kim, Duck Hoi; Cho, Seungyon; Ahn, Mu-Young; Lee, Eun-Seok; Jung, Ki Jung

    2007-01-01

    The allocation of components and systems to be delivered to ITER on an in-kind basis, was agreed between the ITER Parties. Among parties, Korea agreed to procure inboard blanket modules 1, 2 and 6, which consists of FW and shield block. Regarding shield block the detail design and Fabrication techniques development have been undertaken in Korea. Especially manufacturing feasibility study on shield block had been performed and some technical issues for the fabrication were selected. Based on these results, fabrication techniques using EB welding are being developed. Meanwhile, the detail design of inboard standard module has been carried out. The optimization of flow driver design to improve the cooling performance was executed. And, thermo-hydraulic analysis on half block of inboard standard module was performed. In this study, current status and some results from Fabrication techniques development on ITER blanket shield block are described. The detail design activity and results on shield block are also introduced herein. (orig.)

  3. Analysis of Water Mist Suppression with Foam Additive in Wind Generator

    Institute of Scientific and Technical Information of China (English)

    Chen-Wei Chiu[1; Yin-Tsz Lin[1; Yi-Liang Shu[2

    2015-01-01

    The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, several operating factors were adjusted with the results of each adjustment subsequently measured. The operating factors studied included: operating pressures, foam concentrations, cabin opening issues, and obstacles. Each of the factors was compared with the others so as to find out which combinations would be most suitable for a water mist spray system installed inside a wind turbine cabin. The presence of obstructions hinders the direct impact of the mist spray on the fire source and in average an additional 2 to 3 minutes is required to put out the fire. This study found that the effect of the foam-water ratio is linear. Regardless of the scenario, the optimum mixture ratio is 3%. The line graph shows that the most unsuitable aqueous film-forming mixture ratio is 6%. This experiment found that the main fire extinguishing mechanism of water mist spray is the cooling of a large area via water droplets. This system is very effective in bringing down the temperature. The addition of foam in water mist spray, however, impaired the effectiveness of the cooling effect although the fire control mechanism via emulsification markedly reduced the time required to put out the fire. The increase in foam magnification will considerably enhance the fire extinguishing efficiency.

  4. Detailed requirements document for common software of shuttle program information management system

    Science.gov (United States)

    Everette, J. M.; Bradfield, L. D.; Horton, C. L.

    1975-01-01

    Common software was investigated as a method for minimizing development and maintenance cost of the shuttle program information management system (SPIMS) applications while reducing the time-frame of their development. Those requirements satisfying these criteria are presented along with the stand-alone modules which may be used directly by applications. The SPIMS applications operating on the CYBER 74 computer, are specialized information management systems which use System 2000 as a data base manager. Common software provides the features to support user interactions on a CRT terminal using form input and command response capabilities. These features are available as subroutines to the applications.

  5. Testing for detailed balance in a financial market

    Science.gov (United States)

    Fiebig, H. R.; Musgrove, D. P.

    2015-06-01

    We test a historical price-time series in a financial market (the NASDAQ 100 index) for a statistical property known as detailed balance. The presence of detailed balance would imply that the market can be modeled by a stochastic process based on a Markov chain, thus leading to equilibrium. In economic terms, a positive outcome of the test would support the efficient market hypothesis, a cornerstone of neo-classical economic theory. In contrast to the usage in prevalent economic theory the term equilibrium here is tied to the returns, rather than the price-time series. The test is based on an action functional S constructed from the elements of the detailed balance condition and the historical data set, and then analyzing S by means of simulated annealing. Checks are performed to verify the validity of the analysis method. We discuss the outcome of this analysis.

  6. Detailed Astrometric Analysis of Pluto

    Science.gov (United States)

    ROSSI, GUSTAVO B.; Vieira-Martins, R.; Camargo, J. I.; Assafin, M.

    2013-05-01

    Abstract (2,250 Maximum Characters): Pluto is the main representant of the transneptunian objects (TNO's), presenting some peculiarities such as an atmosphere and a satellite system with 5 known moons: Charon, discovered in 1978, Nix and Hydra, in 2006, P4 in 2011 and P5 in 2012. Until the arrival of the New Horizons spacecraft to this system (july 2015), stellar occultations are the most efficient method, from the ground, to know physical and dinamical properties of this system. In 2010, it was evident a drift in declinations (about 20 mas/year) comparing to the ephemerides. This fact motivated us to remake the reductions and analysis of a great set of our observations at OPD/LNA, in a total of 15 years. The ephemerides and occultations results was then compared with the astrometric and photometric reductions of CCD images of Pluto (around 6500 images). Two corrections were used for a refinement of the data set: diferential chromatic refraction and photocenter. The first is due to the mean color of background stars beeing redder than the color of Pluto, resulting in a slightly different path of light through the atmosphere (that may cause a difference in position of 0.1”). It became more evident because Pluto is crossing the region of the galactic plane. The photocenter correction is based on two gaussians curves overlapped, with different hights and non-coincident centers, corresponding to Pluto and Charon (since they have less than 1” of angular separation). The objective is to separate these two gaussian curves from the observed one and find the right position of Pluto. The method is strongly dependent of the hight of each of the gaussian curves, related to the respective albedos of charon and Pluto. A detailed analysis of the astrometric results, as well a comparison with occultation results was made. Since Pluto has an orbital period of 248,9 years and our interval of observation is about 15 years, we have around 12% of its observed orbit and also, our

  7. [Traditional Chinese medicine inheritance system analysis of professor Ding Yuanqing in treating tic disorder medication based on experience].

    Science.gov (United States)

    Sun, Lu-yan; Li, Qing-peng; Zhao, Li-li; Ding, Yuan-qing

    2015-08-01

    In recent years, the incidence of tic disorders has increased, and it is not uncommon for the patients to treat the disease. The pathogenesis and pathogenesis of Western medicine are not yet clear, the clinical commonly used western medicine has many adverse reactions, traditional Chinese medicine (TCM) research is increasingly valued. Based on the software of TCM inheritance assistant system, this paper discusses Ding Yuanqing's experience in treating tic disorder with Professor. Collect yuan Qing Ding professor in treating tic disorder of medical records by association rules Apriori algorithm, complex system entropy clustering without supervision and data mining method, carries on the analysis to the selected 800 prescriptions, to determine the frequency of use of prescription drugs, the association rules between the drug and digging out the 12 core combination and the first six new prescription, medication transferred to the liver and extinguish wind, cooling blood and relieving convulsion, Qingxin soothe the nerves, with the card cut, flexible application, strict compatibility.

  8. Detailed sectional anatomy of the spine

    International Nuclear Information System (INIS)

    Rauschning, W.

    1985-01-01

    Morphologic studies on the human spine constitute a special challenge because of the spine's complex topographic anatomy and the intimate relationship between the supporting skeleton and the contiguous soft tissues (muscles, discs, joint capsules) as well as the neurovascular contents of the spinal canal and intervertebral foramina. The improving resolution and multiplanar image reformatting capabilities of modern CT scanners call for accurate anatomic reference material. Such anatomic images should be available without distortion, in natural colors, and in considerable detail. The images should present the anatomy in the correct axial, sagittal, and coronal planes and should also be sufficiently closely spaced so as to follow the thin cuts of modern CT scanners. This chapter details one of several recent attempts to correlate gross anatomy with the images depicted by high-resolution CT. The methods of specimen preparation, sectioning, and photographing have been documented elsewhere

  9. Combustion and extinction of magnesium fires

    International Nuclear Information System (INIS)

    Malet, J.C.; Duverger de Cuy, G.

    1988-01-01

    The studies made in France on magnesium combustion and extinguishing means are associated at the nuclear fuel of the graphite-gas reactor. Safety studies are made for ameliorate our knowledge on: - magnesium combustion - magnesium fire propagation - magnesium fire extinguishing [fr

  10. 46 CFR 108.487 - Helicopter deck fueling operations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Helicopter deck fueling operations. 108.487 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.487 Helicopter deck fueling operations. (a) Each helicopter landing deck on which fueling operations are...

  11. 75 FR 81 - Special Conditions: Boeing Model 787-8 Airplane; Overhead Flightcrew Rest Compartment Occupiable...

    Science.gov (United States)

    2010-01-04

    ... and protective breathing equipment (PBE). This analysis should consider the possibility of fire in any..., mechanical or structural failure, or persons standing below or against the crew rest compartment outlets. One..., volume of the compartment, and the ventilation rate. The system must have sufficient extinguishing agent...

  12. 76 FR 22383 - National Fire Codes: Request for Proposals for Revision of Codes and Standards

    Science.gov (United States)

    2011-04-21

    ... Chemical Extinguishing Systems. NFPA 22-2008 Standard for Water 5/23/2011 Tanks for Private Fire Protection... Ensembles for Technical Rescue Incidents. NFPA 1925-2008 Standard on Marine Fire- 5/23/2011 Fighting Vessels... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request...

  13. Remote multi-function fire alarm system based on internet of things

    Science.gov (United States)

    Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu

    2018-05-01

    This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.

  14. Binary blend of carbon dioxide and fluoro ethane as working fluid in transcritical heat pump systems

    Directory of Open Access Journals (Sweden)

    Zhang Xian-Ping

    2015-01-01

    Full Text Available As an eco-friendly working fluid, carbon dioxide or R744 is expected to substitute for the existing working fluids used in heat pump systems. It is, however, challenged by the much higher heat rejection pressure in transcritical cycle compared with the traditional subcritical cycle using freons. There exists a worldwide tendency to utilize blend refrigerants as alternatives. Therefore, a new binary blend R744/R161 in this research is proposed in order to decrease the heat rejection pressure. Meanwhile, on mixing R744 with R161, the flammability and explosivity of R161 can be suppressed because of the extinguishing effect of R744. A transcritical thermodynamic model is developed, and then the system performances of heat pump using R744/R161 blend are investigated and compared with those of pure R744 system under the same operation conditions. The variations of heat rejection pressure, heating coefficient of performance, unit volumetric heating capacity, discharge temperature of compressor and the mass fraction of R744/R161 are researched. The results show that R744/R161 mixture can reduce the heat rejection pressure of transcritical heat pump system.

  15. 5 CFR 370.107 - Details to small business concerns.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Details to small business concerns. 370... INFORMATION TECHNOLOGY EXCHANGE PROGRAM § 370.107 Details to small business concerns. (a) The head of each... organizations in each calendar year, at least 20 percent are to small business concerns, in accordance with 5 U...

  16. Detailed modeling of mountain wave PSCs

    Directory of Open Access Journals (Sweden)

    S. Fueglistaler

    2003-01-01

    Full Text Available Polar stratospheric clouds (PSCs play a key role in polar ozone depletion. In the Arctic, PSCs can occur on the mesoscale due to orographically induced gravity waves. Here we present a detailed study of a mountain wave PSC event on 25-27 January 2000 over Scandinavia. The mountain wave PSCs were intensively observed by in-situ and remote-sensing techniques during the second phase of the SOLVE/THESEO-2000 Arctic campaign. We use these excellent data of PSC observations on 3 successive days to analyze the PSCs and to perform a detailed comparison with modeled clouds. We simulated the 3-dimensional PSC structure on all 3 days with a mesoscale numerical weather prediction (NWP model and a microphysical box model (using best available nucleation rates for ice and nitric acid trihydrate particles. We show that the combined mesoscale/microphysical model is capable of reproducing the PSC measurements within the uncertainty of data interpretation with respect to spatial dimensions, temporal development and microphysical properties, without manipulating temperatures or using other tuning parameters. In contrast, microphysical modeling based upon coarser scale global NWP data, e.g. current ECMWF analysis data, cannot reproduce observations, in particular the occurrence of ice and nitric acid trihydrate clouds. Combined mesoscale/microphysical modeling may be used for detailed a posteriori PSC analysis and for future Arctic campaign flight and mission planning. The fact that remote sensing alone cannot further constrain model results due to uncertainities in the interpretation of measurements, underlines the need for synchronous in-situ PSC observations in campaigns.

  17. Antagonism of GABA-B but not GABA-A receptors in the VTA prevents stress- and intra-VTA CRF-induced reinstatement of extinguished cocaine seeking in rats.

    Science.gov (United States)

    Blacktop, Jordan M; Vranjkovic, Oliver; Mayer, Matthieu; Van Hoof, Matthew; Baker, David A; Mantsch, John R

    2016-03-01

    Stress-induced reinstatement of cocaine seeking requires corticotropin releasing factor (CRF) actions in the ventral tegmental area (VTA). However the mechanisms through which CRF regulates VTA function to promote cocaine use are not fully understood. Here we examined the role of GABAergic neurotransmission in the VTA mediated by GABA-A or GABA-B receptors in the reinstatement of extinguished cocaine seeking by a stressor, uncontrollable intermittent footshock, or bilateral intra-VTA administration of CRF. Rats underwent repeated daily cocaine self-administration (1.0 mg/kg/ing; 14 × 6 h/day) and extinction and were tested for reinstatement in response to footshock (0.5 mA, 0.5" duration, average every 40 s; range 10-70 s) or intra-VTA CRF delivery (500 ng/side) following intra-VTA pretreatment with the GABA-A antagonist, bicuculline, the GABA-B antagonist, 2-hydroxysaclofen or vehicle. Intra-VTA bicuculline (1, 10 or 20 ng/side) failed to block footshock- or CRF-induced cocaine seeking at either dose tested. By contrast, 2-hydroxysaclofen (0.2 or 2 μg/side) prevented reinstatement by both footshock and intra-VTA CRF at a concentration that failed to attenuate food-reinforced lever pressing (45 mg sucrose-sweetened pellets; FR4 schedule) in a separate group of rats. These data suggest that GABA-B receptor-dependent CRF actions in the VTA mediate stress-induced cocaine seeking and that GABA-B receptor antagonists may have utility for the management of stress-induced relapse in cocaine addicts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Association Between Academic Medical Center Pharmaceutical Detailing Policies and Physician Prescribing.

    Science.gov (United States)

    Larkin, Ian; Ang, Desmond; Steinhart, Jonathan; Chao, Matthew; Patterson, Mark; Sah, Sunita; Wu, Tina; Schoenbaum, Michael; Hutchins, David; Brennan, Troyen; Loewenstein, George

    2017-05-02

    In an effort to regulate physician conflicts of interest, some US academic medical centers (AMCs) enacted policies restricting pharmaceutical representative sales visits to physicians (known as detailing) between 2006 and 2012. Little is known about the effect of these policies on physician prescribing. To analyze the association between detailing policies enacted at AMCs and physician prescribing of actively detailed and not detailed drugs. The study used a difference-in-differences multivariable regression analysis to compare changes in prescribing by physicians before and after implementation of detailing policies at AMCs in 5 states (California, Illinois, Massachusetts, Pennsylvania, and New York) that made up the intervention group with changes in prescribing by a matched control group of similar physicians not subject to a detailing policy. Academic medical center implementation of policies regulating pharmaceutical salesperson visits to attending physicians. The monthly within-drug class market share of prescriptions written by an individual physician for detailed and nondetailed drugs in 8 drug classes (lipid-lowering drugs, gastroesophageal reflux disease drugs, diabetes drugs, antihypertensive drugs, hypnotic drugs approved for the treatment of insomnia [sleep aids], attention-deficit/hyperactivity disorder drugs, antidepressant drugs, and antipsychotic drugs) comparing the 10- to 36-month period before implementation of the detailing policies with the 12- to 36-month period after implementation, depending on data availability. The analysis included 16 121 483 prescriptions written between January 2006 and June 2012 by 2126 attending physicians at the 19 intervention group AMCs and by 24 593 matched control group physicians. The sample mean market share at the physician-drug-month level for detailed and nondetailed drugs prior to enactment of policies was 19.3% and 14.2%, respectively. Exposure to an AMC detailing policy was associated with a

  19. Author Details

    African Journals Online (AJOL)

    Abstract PDF · Vol 7, No 1 (2010) - Articles Development of a computer aided learning system for graphical analysis of continuous time control systems. Abstract PDF · Vol 8, No 2 (2011) - Articles Genetic algorithm-based precision tuning of digital P-I-D controller for second-order systems. Abstract PDF. ISSN: 2437-2110.

  20. Research on the Hotel Image Based on the Detail Service

    Science.gov (United States)

    Li, Ban; Shenghua, Zheng; He, Yi

    Detail service management, initially developed as marketing programs to enhance customer loyalty, has now become an important part of customer relation strategy. This paper analyzes the critical factors of detail service and its influence on the hotel image. We establish the theoretical model of influencing factors on hotel image and propose corresponding hypotheses. We use applying statistical method to test and verify the above-mentioned hypotheses. This paper provides a foundation for further study of detail service design and planning issues.

  1. 75 FR 221 - Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire...

    Science.gov (United States)

    2010-01-05

    ... Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire Extinguishers as Installed... specification, have been supplied to the aviation industry for use in fire extinguishing equipment. * * * * * * * * * * * This Halon 1211 has subsequently been used to fill certain FFE [Fire Fighting Enterprises] portable...

  2. Oxygen safety

    Science.gov (United States)

    ... sure you have working smoke detectors and a working fire extinguisher in your home. If you move around the house with your oxygen, you may need more than one fire extinguisher in different locations. Smoking can be very dangerous. No one should smoke ...

  3. Pharmaceutical drug detailing in primary care: extent and methods

    DEFF Research Database (Denmark)

    Schramm, Jesper

    The dimension and methods of pharmaceutical marketing towards 47 danish general practitioners is described. Conclusions: Pharmaceutical drug detailing possesses a huge potential to influence the prescription pattern of GP's.......The dimension and methods of pharmaceutical marketing towards 47 danish general practitioners is described. Conclusions: Pharmaceutical drug detailing possesses a huge potential to influence the prescription pattern of GP's....

  4. A detailed analysis of the HD 73526 2:1 resonant planetary system

    Energy Technology Data Exchange (ETDEWEB)

    Wittenmyer, Robert A.; Horner, Jonathan; Tinney, C. G.; Salter, G. S.; Bailey, J.; Wright, D. [School of Physics, University of New South Wales, Sydney 2052 (Australia); Tan, Xianyu; Lee, Man Hoi [Department of Earth Sciences, The University of Hong Kong, Pokfulam Road (Hong Kong); Butler, R. P.; Arriagada, P. [Department of Terrestrial Magnetism, Carnegie Institution of Washington, 5241 Broad Branch Road, NW, Washington, DC 20015-1305 (United States); Carter, B. D. [Faculty of Sciences, University of Southern Queensland, Toowoomba, Queensland 4350 (Australia); Jones, H. R. A. [University of Hertfordshire, Centre for Astrophysics Research, Science and Technology Research Institute, College Lane, AL10 9AB, Hatfield (United Kingdom); O' Toole, S. J. [Australian Astronomical Observatory, PO Box 915, North Ryde, NSW 1670 (Australia); Crane, J. D.; Schectman, S. A.; Thompson, I. [The Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Minniti, D.; Diaz, M., E-mail: rob@phys.unsw.edu.au [Institute of Astrophysics, Pontificia Universidad Catolica de Chile, Casilla 306, Santiago 22 (Chile)

    2014-01-10

    We present six years of new radial velocity data from the Anglo-Australian and Magellan Telescopes on the HD 73526 2:1 resonant planetary system. We investigate both Keplerian and dynamical (interacting) fits to these data, yielding four possible configurations for the system. The new data now show that both resonance angles are librating, with amplitudes of 40° and 60°, respectively. We then perform long-term dynamical stability tests to differentiate these solutions, which only differ significantly in the masses of the planets. We show that while there is no clearly preferred system inclination, the dynamical fit with i = 90° provides the best combination of goodness-of-fit and long-term dynamical stability.

  5. Elliptical posts allow for detailed control of non-equibiaxial straining of cell cultures

    DEFF Research Database (Denmark)

    Olesen, Christian Gammelgaard; Pennisi, Cristian Pablo; de Zee, Mark

    2013-01-01

    tissue cells in vivo are subjected to a range of mechanical deformations including shear strain caused by activities of daily living. Shear strains are suspected to play an important role in tissue necrosis. Method The Flexcell system was redesigned using a finite element model in order to obtain large...... areas of the membrane in a controlled, uniform non-equibiaxial strain state. Results The redesign was manufactured and the resulting strains were experimentally validated by means of image analysis methods. The results showed that the system could be used for experiments varying the shear strain....... Conclusion The result allows scientists and experimentalists to apply detailed control of the strain tensor applied to tissue samples in two dimensions....

  6. Extinguishing a Permian World

    NARCIS (Netherlands)

    Schneebeli-Hermann, E.

    2012-01-01

    At the end of the Permian, ca. 252 Ma ago, marine and terrestrial fauna were facing the most extensive mass extinction in Earth history (Raup and Sepkoski, 1982). 80%–95% of all species on Earth, on land and in the oceans, became extinct (Benton et al., 2004) within an estimated time interval of

  7. Ensemble coding of context-dependent fear memory in the amygdala.

    Science.gov (United States)

    Orsini, Caitlin A; Yan, Chen; Maren, Stephen

    2013-01-01

    After fear conditioning, presenting the conditioned stimulus (CS) alone yields a context-specific extinction memory; fear is suppressed in the extinction context, but renews in any other context. The context-dependence of extinction is mediated by a brain circuit consisting of the hippocampus, prefrontal cortex (PFC) and amygdala. In the present work, we sought to determine at what level of this circuit context-dependent representations of the CS emerge. To explore this question, we used cellular compartment analysis of temporal activity by fluorescent in situ hybridization (catFISH). This method exploits the intracellular expression profile of the immediate early gene (IEG), Arc, to visualize neuronal activation patterns to two different behavioral experiences. Rats were fear conditioned in one context and extinguished in another; 24 h later, they were sequentially exposed to the CS in the extinction context and another context. Control rats were also tested in each context, but were never extinguished. We assessed Arc mRNA expression within the basal amygdala (BA), lateral amygdala (LA), ventral hippocampus (VH), prelimbic cortex (PL) and infralimbic cortex (IL). We observed that the sequential retention tests induced context-dependent patterns of Arc expression in the BA, LA, and IL of extinguished rats; this was not observed in non-extinguished controls. In general, non-extinguished animals had proportionately greater numbers of non-selective (double-labeled) neurons than extinguished animals. Collectively, these findings suggest that extinction learning results in pattern separation, particularly within the BA, in which unique neuronal ensembles represent fear memories after extinction.

  8. Ensemble coding of context-dependent fear memory in the amygdala

    Directory of Open Access Journals (Sweden)

    Caitlin A Orsini

    2013-12-01

    Full Text Available After fear conditioning, presenting the conditioned stimulus (CS alone yields a context-specific extinction memory; fear is suppressed in the extinction context, but renews in any other context. The context-dependence of extinction is mediated by a brain circuit consisting of the hippocampus, prefrontal cortex and amygdala. In the present work, we sought to determine at what level of this circuit context-dependent representations of the CS emerge. To explore this question, we used cellular compartment analysis of temporal activity by fluorescent in situ hybridization (catFISH. This method exploits the intracellular expression profile of the immediate early gene, Arc, to visualize neuronal activation patterns to two different behavioral experiences. Rats were fear conditioned in one context and extinguished in another; twenty-four hours later, they were sequentially exposed to the CS in the extinction context and another context. Control rats were also tested in each context, but were never extinguished. We assessed Arc mRNA expression within the basal amygdala (BA, lateral amygdala (LA, ventral hippocampus (VH, prelimbic cortex (PL and infralimbic cortex (IL. We observed that the sequential retention tests induced context-dependent patterns of Arc expression in the BA, LA, and IL of extinguished rats; this was not observed in non-extinguished controls. In general, non-extinguished animals had proportionately greater numbers of non-selective (double-labeled neurons than extinguished animals. Collectively, these findings suggest that extinction learning results in pattern separation, particularly within the BA, in which unique neuronal ensembles represent fear memories after extinction.

  9. 16 CFR 1750.5 - Detailed requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Detailed requirements. 1750.5 Section 1750.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION REFRIGERATOR SAFETY ACT REGULATIONS STANDARD FOR... directed perpendicularly to the plane of the door and applied anywhere along the latch edge of the inside...

  10. 78 FR 32081 - Airworthiness Directives; Aircraft Industries a.s. Airplanes

    Science.gov (United States)

    2013-05-29

    ... Injection System WATER INJECTION circuit ON breakter. TCL TQ=min. 60% WATER INJECTION/ON push- Push and hold till amber button. WATER INJECTION signal comes on (on the front control panel) Before throttling back power: WATER INJECTION/OFF push- Push and check amber button. WATER INJECTION signal extinguishes...

  11. 46 CFR 27.209 - What are the requirements for training crews to respond to fires?

    Science.gov (United States)

    2010-10-01

    ... are familiar with their fire-fighting duties, and, specifically, with the following contingencies: (1) Fighting a fire in the engine room and elsewhere on board the vessel, including how to— (i) Operate all of the fire-extinguishing equipment on board the vessel; (ii) Stop any mechanical ventilation system for...

  12. 49 CFR 176.69 - General stowage requirements for hazardous materials.

    Science.gov (United States)

    2010-10-01

    ... equipped with a fixed fire extinguishing and fire detection system, the freight containers or barges need... by paragraph (a) of this section if fire fighting equipment capable of reaching and piercing the..., their removal from a potentially dangerous situation, and the removal of packages in case of fire. (b...

  13. Detailed description of an SSAC at the facility level for on-load refueled power reactor facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-11-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in an on-load refueled power reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  14. EFFICIENCY OF FIRE-FIGHTING PROTECTION OBJECTS IN PROVISION OF FIRE SAFETY AT INDUSTRIAL ENTERPRISES

    OpenAIRE

    A. V. Zhovna

    2008-01-01

    The paper gives an analysis of economic results pertaining to organization of a system for fire-fighting protection of industrial enterprises in theRepublicofBelarus. Statistical data on operational conditions of technical means of fire-fighting protection, particularly, automatic systems for detection and extinguishing of fires, systems of internal fire-fighting water-supply.  Requirements and provisions  of normative and technical documents are thoroughly studied. Observance of these docume...

  15. Specificity and detail in autobiographical memory: Same or different constructs?

    Science.gov (United States)

    Kyung, Yoonhee; Yanes-Lukin, Paula; Roberts, John E

    2016-01-01

    Research on autobiographical memory has focused on whether memories are coded as specific (i.e., describe a single event that happened at a particular time and place). Although some theory and research suggests that the amount of detail in autobiographical memories reflects a similar underlying construct as memory specificity, past research has not investigated whether these variables converge. Therefore, the present study compared the proportion of specific memories and the amount of detail embedded in memory responses to cue words. Results demonstrated that memory detail and proportion of specific memories were not correlated with each other and showed different patterns of association with other conceptually relevant variables. When responses to neutral cue words were examined in multiple linear and logistic regression analyses, the proportion of specific memories uniquely predicted less depressive symptoms, low emotional avoidance, lower emotion reactivity, better executive control and lower rumination, whereas the amount of memory detail uniquely predicted the presence of depression diagnosis, as well as greater depressive symptoms, subjective stress, emotion reactivity and rumination. Findings suggest that the ability to retrieve specific memories and the tendency to retrieve detailed personal memories reflect different constructs that have different implications in the development of emotional distress.

  16. Detailed Safety Review of Anthrax Vaccine Adsorbed

    National Research Council Canada - National Science Library

    2001-01-01

    To date, 18 human studies have assessed the safety of anthrax vaccination. These studies, some stretching back almost 50 years, reported adverse events after vaccination in varying degrees of detail...

  17. Describing the processes of propagation and eliminating wildfires with the use of agent models

    Directory of Open Access Journals (Sweden)

    G. A. Dorrer

    2017-10-01

    Full Text Available A new method of describing the processes of propagation and elimination of wildfires on the basis of agent-based modeling is proposed. The main structural units of the creation of such models are the classes of active objects (agents. Agent approach, combined with Geographic Information Systems (GIS can effectively describe the interaction of a large number of participants in the process to combat wildfires: fire spreading, fire crews, mechanization, aerial means and other. In this paper we propose a multi-agent model to predict the spread of wildfire edge and simulate the direct method of extinguishing a ground fire with non-mechanized crews. The model consist with two classes of agents, designated A and B. The burning fire edge is represented as a chain of A-agents, each of which simulates the burning of an elementary portion of vegetation fuel. Fire front movement (moving the A-agent described by the Hamilton-Jacobi equation with using the indicatrises of normal front rate of spread (figurotris. The configuration of the front calculated on basis the algorithm of mobile grids. Agents other type, B-agents, described extinguishing process; they move to the agents of A type and act on them, reducing the combustion intensity to zero. Modeling system presented as two-level coloured nested Petri Net, which describes the agents’ interaction semantics. This model is implemented as a GIS-oriented software system that can be useful both in the fire fighting management as well as in staff training tactics to fighting wildfires. Some examples of modeling decision making on а ground fire extinguishing are presented.

  18. A study on the fire response of compressed hydrogen gas vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Yohsuke; Tomioka, Junichi; Suzuki, Jinji [Japan Automobile Research Institute (Japan)

    2010-07-01

    To investigate the events that could arise when fighting fires in vehicles with compressed hydrogen CFRP (carbon fiber reinforced plastic) composite cylinders, we conducted experiments to examine whether a hydrogen jet flame caused by the activation of the pressure relief device (PRD) can extinguished and how spraying water influences the cylinder and PRD. The experiments clarified that the hydrogen jet flame cannot be extinguished easily with water or dry powder extinguishers and that spraying water during activation of the PRD may result in closure of the PRD, but is useful for maintaining the strength of CFRP composite cylinders for vehicles. (orig.)

  19. Technical Details on Beyond Design Basis Event Pilot Evaluations

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2013-01-01

    The primary focus of the BDBE pilot project was the review of BDBE analysis and mitigation features at four DOE nuclear facilities representing a range of DOE sites, nuclear facility types/activities, and responsible program offices. The pilots looked at (1) how beyond design basis accidents were evaluated and documented in the facility Documented Safety Analysis, (2) potential BDBE vulnerabilities and margins to failure of facility safety features as obtained from general area and specific system walkdowns and design documents reviews, and (3) preparations made in facility and site emergency management programs to respond to severe accidents. It also evaluated whether draft BDBE guidance on safety analysis and emergency management could be used to improve the analysis of and preparations for mitigating severe and beyond design basis accidents. The details of these activities are organized in this report as described below.

  20. Capturing the Landauer bound through the application of a detailed Jarzynski equality for entropic memory erasure.

    Science.gov (United States)

    Das, Moupriya

    2014-12-01

    The states of an overdamped Brownian particle confined in a two-dimensional bilobal enclosure are considered to correspond to two binary values: 0 (left lobe) and 1 (right lobe). An ensemble of such particles represents bits of entropic information. An external bias is applied on the particles, equally distributed in two lobes, to drive them to a particular lobe erasing one kind of bit of information. It has been shown that the average work done for the entropic memory erasure process approaches the Landauer bound for a very slow erasure cycle. Furthermore, the detailed Jarzynski equality holds to a very good extent for the erasure protocol, so that the Landauer bound may be calculated irrespective of the time period of the erasure cycle in terms of the effective free-energy change for the process. The detailed Jarzynski equality applied to two subprocesses, namely the transition from entropic memory state 0 to state 1 and the transition from entropic memory state 1 to state 1, connects the work done on the system to the probability to occupy the two states under a time-reversed process. In the entire treatment, the work appears as a boundary effect of the physical confinement of the system not having a conventional potential energy barrier. Finally, an analytical derivation of the detailed and classical Jarzynski equality for Brownian movement in confined space with varying width has been proposed. Our analytical scheme supports the numerical simulations presented in this paper.