WorldWideScience

Sample records for externally loaded bolted

  1. Inexpensive Bolt-Load Gage

    Science.gov (United States)

    Long, M. J.

    1983-01-01

    "Built-in" gage determines whether large bolt or stud has been torqued to desired load and provides for continuous inspection to ensure proper load is being maintained. Gage detects longitudinal stress/strain bolt; requires no electronic or sonic test equipment.

  2. Limit load analysis of bolted flange connections

    International Nuclear Information System (INIS)

    Kauer, R.; Deininger, J.

    2005-01-01

    In Europe as well as in other countries a lot of efforts are invested into developing new codes and standards for bolted joints under various loading conditions. The standardization of gasket factors and the improvement of calculation methods with respect to these factors characterize the last couple of years in this area. In Germany, the nuclear code (KTA-Regeln) is also influenced by this development. So, the leak rate dependency of gasket factors and the results of a research program on metal-to-metal contact type flanges were introduced into the new approach of the code for Class 2 and 3 components. Herein; flange calculations can be performed for various flange types, floating type and metal-to-metal contact type. Generally, the calculations to be performed can be separated into a design step and the proof of sufficient tightness and strength of flange, bolts and gasket for the various operating conditions according to the chosen bolting method. In Europe, the most recent development in the field of flange calculations is the new standard EN 1591-1 for flange connections. The structure of the EN 1591-1 is also a two-step approach, but due to the more sophisticated and iterative calculation method, the design step is neglected and instead the focus in the first step is the determination of a suitable bolting force. In cases, where the allowable stress values are not satisfied by performing code calculations or in cases, where the applicability of the code is not given, e. g. due to geometric facts, Finite-Element analyses often replace code calculations but have to demonstrate code compliance. Therefore, numerical Finite-Element analyses, performed according to a special code, e. g. KTA, must also fulfill the requirements of the code with respect to considered load cases, bolting condition, allowable stresses etc., to get an adequate testimony for a certain flange joint. Usually this can be done by checking relevant cross sections according to the stress

  3. Effects of bolt pre-loading variations on performance of GDL in a bolted PEMFC by 3-D FEM analysis

    International Nuclear Information System (INIS)

    Chien, Chi-Hui; Hu, Yao-Lun; Su, Ting-Hsuan; Liu, Hsuan-Ting; Wang, Chung-Ting; Yang, Ping-Feng; Lu, Ying-Xu

    2016-01-01

    This study numerically investigated the effects of different bolt pre-loadings on the performance of the gas diffusion layer (GDL) in a bolted proton exchange membrane fuel cell (PEMFC). Firstly, a complete three-dimensional finite element model of a PEMFC bolted by 12 bolts with a reactive area of 5 cm by 5 cm was established using the commercial software SolidWorks. Then, a pre-loading of 1 MPa to 7 MPa on each bolt was applied, increasing in increments 1 MPa, and the corresponding deformation and stress fields of each component of the fuel cell were obtained using the commercial software ANSYS 15.0/Workbench. Finally, the effects of the bolt pre-loading variations on the performance of the GDL were discussed. The results showed that the compression ratio of the GDL increased linearly with the magnitude of bolt pre-loading, and improving the performance of the GDL. However, when the pre-loading on each bolt reached 7 MPa, the compression ratio exceeded 15%, degrading the efficiency of the PEMFC. Also, by comparing the relationships between bolt pre-loading and conductivity and porosity of GDL, in order to obtain the maximum performance of GDL, an optimum value of 4 MPa for bolt preloading was recommended. - Highlights: • Effect of bolt pre-loading on deformations is more serious than that of thermal loading. • Bolt pre-loading improves compression ratio of GDL. • For obtaining a maximum performance of GDL, 4 MPa of bolt pre-loading was recommended. • Flow channel volume reduced by bolt pre-loading degrades the efficiency of PEMFC.

  4. Ultimate load capacities of expansion anchor bolts

    International Nuclear Information System (INIS)

    Czarnecki, R.M.; Manrique, M.A.; Samaddar, S.K.

    1993-01-01

    A summary of available experimental expansion anchor bolt test data is presented. These data were collected as part of programs by the nuclear industry to address generic issues related to verification of seismic adequacy of equipment in nuclear power plants. Some of the data presented are suitable for use in seismic probabilistic risk assessments. For example, mean values of ultimate strength, along with their standard deviation and coefficients of variation, for a range of most typical expansion anchor bolt sizes are presented. Effects of interaction between shear and tension, edge distance, spacing, and cracking of the concrete are presented in a manner that is more suitable for use in deterministic evaluations. Related industry programs to derive anchor bolt capacities are briefly discussed. Recommendations for areas of further investigation are also presented

  5. Strength of Glued-in Bolts after Full Scale Loading

    DEFF Research Database (Denmark)

    Pedersen, Martin Bo Uhre; Clorius, Christian Odin; Damkilde, Lars

    1999-01-01

    with a length of 500 mm had a special hollow tapering giving them a higher load bearing capacity than solid bolts of equal dimensions. A FEM-analysis confirms the higher load bearing capacity. The mean residual strength was found to be 362 kN with a standard deviation of 37 kN, which is 95% of the predicted...

  6. Influence of Thread Root Radius on Maximum Local Stresses at Large Diameter Bolts under Axial Loading

    Directory of Open Access Journals (Sweden)

    Cojocaru Vasile

    2014-06-01

    Full Text Available In the thread root area of the threaded bolts submitted to axial loading occur local stresses, higher that nominal stresses calculated for the bolts. These local stresses can generate failure and can reduce the fatigue life of the parts. The paper is focused on the study of the influence of the thread root radius on the maximum local stresses. A large diameter trapezoidal bolt was subjected to a static analysis (axial loading using finite element simulation.

  7. Monitoring of Pre-Load on Rock Bolt Using Piezoceramic-Transducer Enabled Time Reversal Method.

    Science.gov (United States)

    Huo, Linsheng; Wang, Bo; Chen, Dongdong; Song, Gangbing

    2017-10-27

    Rock bolts ensure structural stability for tunnels and many other underground structures. The pre-load on a rock bolt plays an important role in the structural reinforcement and it is vital to monitor the pre-load status of rock bolts. In this paper, a rock bolt pre-load monitoring method based on the piezoceramic enabled time reversal method is proposed. A lead zirconate titanate (PZT) patch transducer, which works as an actuator to generate stress waves, is bonded onto the anchor plate of the rock bolt. A smart washer, which is fabricated by sandwiching a PZT patch between two metal rings, is installed between the hex nut and the anchor plate along the rock bolt. The smart washer functions as a sensor to detect the stress wave. With the increase of the pre-load values on the rock bolt, the effective contact surface area between the smart washer and the anchor plate, benefiting the stress wave propagation crossing the contact surface. With the help of time reversal technique, experimental results reveal that the magnitude of focused signal clearly increases with the increase of the pre-load on a rock bolt before the saturation which happens beyond a relatively high value of the pre-load. The proposed method provides an innovative and real time means to monitor the pre-load level of a rock bolt. By employing this method, the pre-load degradation process on a rock bolt can be clearly monitored. Please note that, currently, the proposed method applies to only new rock bolts, on which it is possible to install the PZT smart washer.

  8. Visual recognition of the load of roof-bolts by an indicator

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, J. [Leon Industries (Germany)

    2001-07-01

    Hundreds of bolt-indicators were already used successfully in the German deep hard coal-mines to increase the safety and economy. The bolt-indicator offers the simple possibility to guard roof-bolt loads, to state weak points as well as to optimize the anchor density and the dimension. The bolt-indicator are mushroom shaped and are of coated metal. It is brought in between the anchor plate and the anchor mother. The loads appearing at the anchor will transfer to the bolt-indicators and can be recognized visually at the cylindrical part by the amount of the surface coating. A select example clarifies itself application aims, operation and a usage of the bolt-indicator and the yielding advantages in practice. (orig.)

  9. A Design Method for the Tension Side of Statically Loaded, Bolted Beam-to-Column Connections

    NARCIS (Netherlands)

    Zoetemeijer, P.

    1974-01-01

    In this paper a design method for the tension side of statically loaded, bolted beam-to-column connections is developed based on the plastic behaviour of the flanges and the bolts under the assumption that the plastification is large enough to allow the adoption of the most favourable static

  10. Fewer complications with bolt-connected than tunneled external ventricular drainage

    DEFF Research Database (Denmark)

    Jensen, Torben Slott; Carlsen, Jakob Gram; Poulsen, Frantz Rom

    2016-01-01

    BACKGROUND: Ventriculostomy/external ventricular drain (EVD) is a common neurosurgical procedure. Various techniques are used to fixate the drain and the objective of this study was, in a retrospective setting, to compare the incidence of complications when using bolt-connected EVD (BC-EVD) versus...... tunneled EVD (T-EVD). METHODS: All patients subjected to an EVD performed through a new burr hole from 2009 through 2010 at two Depts. of Neurosurgery in Denmark (Odense and Aarhus) were retrospectively identified. Patient files were evaluated for EVD fixation technique (tunneled or bolt-connected EVD...... %), compared to the bolt-connected EVD group (6.5 %). There was no significant difference in infection rates. CONCLUSIONS: Tunneled EVD has a relatively high frequency of complications leading to reinsertion. The use of Bolt-connected EVD technique can lower this frequency significantly. The number needed...

  11. The structural behavior of a bolted flanged connection subjected to a cyclic load

    International Nuclear Information System (INIS)

    Cesari, F.

    1981-01-01

    In the vessel of BWR nuclear plants, the bolted flanged connection is subjected to a cyclic load, consisting of four steps: the bolt load, the pressure load with decreasing of bolt load, depressurization with increasing bold load, and at the end, unbolting. In the case of rigid, bolted flange, the elastic behavior is essentially correct, but if the height of the flange is decreased, then the stress gradients are so high that the strains move into the plastic range. In addition, the design of pressure vessels is not complete without an appraisal of failure by progressive distortion or stress ratchteing. There is therefore a need for numerical results for the structures subjected to well-known loading. The aim of this paper is to follow the stress and strain of a bolted flange subjected to the cyclic load, progressively varying the height of the flange, so that the maximum stress intensity becomes 3 Ssub(m). The number of cycles was sufficient to verify the conditions of shakedown or ratcheting. The numerical analysis, using finite element technique and the Adina code, is well established and frequently used. (orig.)

  12. Site ultrasonic measurement on RPV stud-bolt loading under hot transient of Qinshan NPP

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang; Zhu Shiming

    1994-08-01

    It expounds that the key of solving thermal transient sealing problem is to obtain the thermal increment of stud-bolt loading. This loading, as a primary stress loading, is directly related to the bolt fatigue life and transient loading spectrum for vessel analysis. The fundamental works and main results of ultrasonic measurement on RPV stud-bolt loading on Qinshan site are also presented. The measuring capability has exceeded 1 m in length and temperature of 280 degree C, therefore, it is possible to be used in the field of NPP. The paper is the continuation of research work for sealing analysis and tests on the RPV (see SMiRT-9, 10)

  13. Study on Mechanical Characteristics of Fully Grouted Rock Bolts for Underground Caverns under Seismic Loads

    Directory of Open Access Journals (Sweden)

    Guoqing Liu

    2017-01-01

    Full Text Available This study establishes an analytical model for the interaction between the bolt and surrounding rock based on the bearing mechanism of fully grouted rock bolts. The corresponding controlled differential equation for load transfer is deduced. The stress distributions of the anchorage body are obtained by solving the equations. A dynamic algorithm for the bolt considering shear damage on the anchoring interface is proposed based on the dynamic finite element method. The rationality of the algorithm is verified by a pull-out test and excavation simulation of a rounded tunnel. Then, a case study on the mechanical characteristics of the bolts in underground caverns under seismic loads is conducted. The results indicate that the seismic load may lead to stress originating from the bolts and damage on the anchoring interface. The key positions of the antiseismic support can be determined using the numerical simulation. The calculated results can serve as a reference for the antiseismic optimal design of bolts in underground caverns.

  14. Ultrasonic measurement on RPV stud-bolt loading under hot transient of Qinshan NPP

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang; Zhu Shiming; Lu Jie; Wang Yingguan

    1994-01-01

    It is a continuation of research work for sealing analysis and tests on the PRV of PWR. It expounds that the key of solving thermal transient sealing problem lies in giving the thermal increment of stud-bolt fatigue life and transient loading spectrum for vessel analysis. The authors recounted the fundamental works and main results of ultrasonic measurement on RPV stud-bolt loading on the reactor of Qinshan Nuclear Power Plant. The measuring capability exceeds 1 m length and 300 degree C temperature. Therefore, it is possible to be used in the field of NPP

  15. Behavior of single lap composite bolted joint under traction loading: Experimental investigation

    Science.gov (United States)

    Awadhani, L. V.; Bewoor, Anand

    2018-04-01

    Composite bolted joints are preferred connection in the composite structures to facilitate the dismantling for the replacements/ maintenance work. The joint behavior under tractive forces has been studied in order to understand the safety of the structure designed. The main objective of this paper is to investigate the behavior of single-lap joints in carbon fiber reinforced epoxy composites under traction loading conditions. The experiments were designed to identify the effect of bolt diameter, stacking sequence and loading rate on the properties of the joint. The experimental results show that the parameters influence the joint performance significantly.

  16. Evaluation of Many Load Tests of Passive Rock Bolts in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Holý Ondřej

    2017-03-01

    Full Text Available Within the research project “FR-TI4/329 Research and development - creating an application system for the design and analysis of soil and rock anchors including the development of monitoring elements”, an extensive stage of field load tests of rock bolts was carried out. The tests were conducted at 14 locations with varied rock composition. Before the initial tests, a loading stand was designed and constructed. A total of 201 pieces of tensile tests of bolts having lengths from 0.5 up to 2.5 m, a diameter of 22-32 mm, were performed. These were fully threaded rods, self-drilling rods, and fiberglass rods. The bolts were clamped into the cement and resin. The loading tests were always performed until material failure of bolts or shear stress failure at the interface cement-rock. At each location, basic geotechnical survey was carried out in the form of core drilling in a length of 3.0 metres with the assessment of the rock mass in situ, and laboratory testing of rock mechanics. Upon the completion of testing protocols, rock mass properties analysis was performed focusing on the evaluation of shear friction at the grouting-rock interface.

  17. STAMINA OF A GASKETED BOLTED FLANGED PIPE JOINT UNDER DYNAMIC LOADING

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2016-11-01

    Full Text Available Gasketed bolted flange joints are the most critical components in pipelines for their sealing and strength under operating conditions. Most of the work available in literature is under static loading, whereas in industry, cyclic loads are applied due to the vibrating machinery such as motors, pumps, sloshing in offshore applications and in the ships etc. In this study a three dimensional finite element analysis of a gasketed joint is carried out using a spiral wound gasket under bolt up and dynamic operating conditions (internal pressure, axial and bending singly and in combination. The cyclic axial loads are concluded relatively more challenging for both the sealing and strength of the joint. Higher magnitudes of loads and frequencies are also observed more challenging to the joints performance.

  18. Improved bolt models for use in global analyses of storage and transportation casks subject to extra-regulatory loading

    International Nuclear Information System (INIS)

    Kalan, R.J.; Ammerman, D.J.; Gwinn, K.W.

    2004-01-01

    Transportation and storage casks subjected to extra-regulatory loadings may experience large stresses and strains in key structural components. One of the areas susceptible to these large stresses and strains is the bolted joint retaining any closure lid on an overpack or a canister. Modeling this joint accurately is necessary in evaluating the performance of the cask under extreme loading conditions. However, developing detailed models of a bolt in a large cask finite element model can dramatically increase the computational time, making the analysis prohibitive. Sandia National Laboratories used a series of calibrated, detailed, bolt finite element sub-models to develop a modified-beam bolt-model in order to examine the response of a storage cask and closure to severe accident loadings. The initial sub-models were calibrated for tension and shear loading using test data for large diameter bolts. Next, using the calibrated test model, sub-models of the actual joints were developed to obtain force-displacement curves and failure points for the bolted joint. These functions were used to develop a modified beam element representation of the bolted joint, which could be incorporated into the larger cask finite element model. This paper will address the modeling and assumptions used for the development of the initial calibration models, the joint sub-models and the modified beam model

  19. Mechanical Behaviour of Bolted Joints Under Impact Rates of Loading

    Science.gov (United States)

    2012-01-01

    M. (1995). Bearing Strength of Autoclave and oven cured kevlar / epoxy laminates under static and dynamic loading. Compostes, 451-456. Kretsis, G...Joints in Glass Fibre/ Epoxy Laminates. Composites, Volume 16. No 2. Kolsky, H. (1949). An Investigation of the Mechanical Properties of Materials at...elongating the pulse width. The responses are read by the strain gages bonded on the incident and transmission bar with Vishay AE-10 epoxy . The gages

  20. Behavior of four-bolt extended end-plate connection subjected to lateral loading

    Directory of Open Access Journals (Sweden)

    Elsayed Mashaly

    2011-03-01

    Full Text Available A considerable number of literatures have been published on the behavior of end-plate connections in ordinary moment-resisting frames. It was found, experimentally, that this type of connection might act as either a fully-rigid or a semi-rigid connection depending mainly on the thickness of the end plate and the diameter of bolts. In recent years, due to their good ductility and their good ability of energy dissipation, extended end-plate connections are recommended to be widely used in special moment-resisting frames subjected to lateral loads. The purpose of this study is to investigate the effect of both the material and geometric properties of four-bolt extended end-plate connections upon their behavior when subjected to lateral loading. This is done through a parametric study upon a finite element model using the multi-purpose software package ANSYS. The parametric study takes into account 12 parameters which are expected to be effective on the behavior of the studied connection. The results are presented by the relation between the storey drift, which represents the rotation of the connection and the applied lateral load, which simulates the moment on the connection. The results verify that the chosen parameters are considered effective depending on the energy dissipation of the connection.

  1. Discussion about effecting of stiffener in four bolts in a row end plate connection for long span and heavy load steel structures in Vietnam

    Science.gov (United States)

    Huong, Khang T.; Nguyen, Cung H.

    2018-04-01

    Nowadays, steel structure industry in Vietnam is in strong development. The construction of steel structure becomes larger span and heavier load. The issue spawned a number of issues arise from optimizing connections. Typical of steel connections in prefabricated steel structure that is an end plate (face plate) bolted connection. When the connection carried a heavy load, then the number of bolts is required much more. Increasing the number of rows bolts will less effective because can still not enough strength requirements, the bolts in row near rotational center will level arm reduction, then it cannot carry heavy loads. The current solution is doing multiple bolts in a row. Current standards such as EN [1], AISC [2] are no specific guidelines for calculating the connection four bolts in a row that primarily assumes the way works like a T-stub of the two bolts a row. Some articles studied T-stub four bolts in a row [3], [4], [5], [6] by component method but it has some components which weren’t considered. In this paper, in order to provide a contribution to improve the T-stub four bolts in a row, the stiffener component in T-stub will be added and compared with T-stub without stiffener by the finite element model to demonstrate effectiveness in reducing stress and displacement of T-stub. It gives ideas for the economic design of four bolts in a row end plate connection in Vietnam for future.

  2. Bolt Shear Force Sensor

    Science.gov (United States)

    2015-03-12

    0030] FIG. 7 is an isometric view of a deformable ring of the bolt shear force sensor of the present invention with an optical Attorney Docket No...102587 9 of 19 fiber having Bragg gratings wound around the ring; [0031] FIG. 8 is an isometric view of the deformable ring with wire strain... strength . [0047] Once the joint is subjected to an external load (see force arrows “F” and “F/2”); any frictional resistance to slip is overcome and

  3. Study on Fatigue Performance of Composite Bolted Joints with Bolt-Hole Delamination

    Science.gov (United States)

    Liu, M. J.; Yu, S.; Zhao, Q. Y.

    2018-03-01

    Fatigue performance of composite structure with imperfections is a challenging subject at present. Based on cohesive zone method and multi-continuum theory, delamination evolution response and fatigue life prediction of a 3D composite single-lap joint with a bolt-hole have been investigated through computer codes Abaqus and Fe-safe. Results from the comparison of a perfect composite bolted joint with another defect one indicates that a relatively small delamination damage around the bolt hole brings about significant degradation of local material performance. More notably, fatigue life of stress concentration region of composite bolted joints is highly sensitive to external loads, as an increase of 67% cyclic load amplitude leads to an decrease of 99.5% local fatigue life in this study. However, the numerical strategy for solving composite fatigue problems is meaningful to engineering works.

  4. Automated detection of cracks on the faying surface within high-load transfer bolted speciments

    Science.gov (United States)

    Wheatley, Gregory; Kollgaard, Jeffrey R.

    2003-07-01

    Boeing is currently conducting evaluation testing of the Comparative Vacuum Monitoring (CVMTM) system offered by Structural Monitoring Systems, Ltd (SMS). Initial testing has been conducted by SMS, with further test lab validations to be performed at Boeing in Seattle. Testing has been conducted on dog bone type specimens that have been cut at the center line. A notch was cut at one of the bolt holes and a CVM sensor installed on both sides of the plate. The doublers were added and a single line of 4 bolts along the longitudinal center line were used to attach the doubler plates to the dog bone type specimen. In this way, a high load transfer situation exists between the two halves of the dog bone specimen and the doubler plates. The CVM sensors are slightly over 0.004" (0.1mm) in thickness and are installed directly upon the faying surface of the dog bone specimen. Testing was conducted on an Instron 8501 Servohydraulic testing machine at the Department of Mechanical and Materials Engineering, University of Western Australia. The standard laboratory equipment offered by Structural Monitoring Systems, Ltd was used for crack detection. This equipment included the Kvac (vacuum supply) and the Sim8 (flow meter). The Sim8 was electrically connected to the Instron machine so that as soon as a crack was detected, fatigue loading was halted. The aim of the experiment was for CVM to detect a crack on the faying surface of the specimens at a length of 0.050" +/- 0.010". This was accomplished successfully. CVM has been developed on the principle that a small volume maintained at a low vacuum is extremely sensitive to any ingress of air. In addition to the load bearing sensors described above, self-adhesive, elastomeric sensors with fine channels on the adhesive face have been developed. When the sensors have been adhered to the structure under test, these fine channels, and the structure itself, form a manifold of galleries alternately at low vacuum and atmospheric pressure

  5. Bolting applications

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1984-05-01

    An investigation of bolting practices specific to the nuclear industry was performed. The report covered a large spectrum of topics e.g., bolts embedded in concrete, specifications, inspection of bolting, both at receipt and inservice. Plots of preload versus yield strength for different bolting materials in different environments are presented as well as information relative to the stress corrosion cracking resistance of the more recent reactor internals bolting materials A286 and Inconel X-750. Part of the report contains input by Standard Pressed Steel Inc. (a bolting consultant) relative to bolting standards, cottering methods and potential areas for bolting improvement

  6. 14 CFR 29.865 - External loads.

    Science.gov (United States)

    2010-01-01

    ... 200 volts per meter. (iii) Be protected against any failure that could be induced by a failure mode of... operational envelope without hazard to the rotorcraft during normal flight conditions. In addition, these...-load combinations to be used for nonhuman external cargo except for the failure of critical structural...

  7. Residual Strength of Glued-in Bolts After 9 Years In Situ Loading

    DEFF Research Database (Denmark)

    Pedersen, Martin Bo Uhre; Clorius, Christian Odin; Damkilde, Lars

    1996-01-01

    In 1993 one of the wooden blades of the Nibe-B windmill was struck by lightning and subsequently demounted after 9 years of use. The mishap offered a unique opportunity to investigate the residual strength of the 28 glued-in bolts used to form the blade to rotor hub connection.The test method...

  8. Evaluation of Rock Bolt Support for Polish Hard Rock Mines

    Science.gov (United States)

    Skrzypkowski, Krzysztof

    2018-03-01

    The article presents different types of rock bolt support used in Polish ore mining. Individual point resin and expansion rock bolt support were characterized. The roof classes for zinc and lead and copper ore mines were presented. Furthermore, in the article laboratory tests of point resin rock bolt support in a geometric scale of 1:1 with minimal fixing length of 0.6 m were made. Static testing of point resin rock bolt support were carried out on a laboratory test facility of Department of Underground Mining which simulate mine conditions for Polish ore and hard coal mining. Laboratory tests of point resin bolts were carried out, especially for the ZGH Bolesław, zinc and lead "Olkusz - Pomorzany" mine. The primary aim of the research was to check whether at the anchoring point length of 0.6 m by means of one and a half resin cartridge, the type bolt "Olkusz - 20A" is able to overcome the load.The second purpose of the study was to obtain load - displacement characteristic with determination of the elastic and plastic range of the bolt. For the best simulation of mine conditions the station steel cylinders with an external diameter of 0.1 m and a length of 0.6 m with a core of rock from the roof of the underground excavations were used.

  9. Stress corrosion of low alloy steels used in external bolting on pressurised water reactors

    International Nuclear Information System (INIS)

    Skeldon, P.; Hurst, P.; Smart, N.R.

    1992-01-01

    The stress corrosion cracking (SCC) susceptibility of AISI 4140 and AISI 4340 steels has been evaluated in five environments, three simulating a leaking aqueous boric acid environment and two simulating ambient external conditions ie moist air and salt spray. Both steels were found to be highly susceptible to SCC in all environments at hardnesses of 400 VPN and above. The susceptibility was greatly reduced at hardnesses below 330 VPN but in one environment, viz refluxing PWR primary water, SCC was observed at hardnesses as low as 260VPN. Threshold stress intensities for SCC were frequently lower than those in the literature

  10. Optimization of Bolt Stress

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2013-01-01

    The state of stress in bolts and nuts with ISO metric thread design is examined and optimized. The assumed failure mode is fatigue so the applied preload and the load amplitude together with the stress concentrations define the connection strength. Maximum stress in the bolt is found at, the fillet...... under the head, at the thread start or at the thread root. To minimize the stress concentration shape optimization is applied....

  11. Overall bolt stress optimization

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2013-01-01

    The state of stress in bolts and nuts with International Organization for Standardization metric thread design is examined and optimized. The assumed failure mode is fatigue, so the applied preload and the load amplitude together with the stress concentrations define the connection strength....... Maximum stress in the bolt is found at the fillet under the head, at the thread start, or at the thread root. To minimize the stress concentration, shape optimization is applied. Nut shape optimization also has a positive effect on the maximum stress. The optimization results show that designing a nut......, which results in a more evenly distribution of load along the engaged thread, has a limited influence on the maximum stress due to the stress concentration at the first thread root. To further reduce the maximum stress, the transition from bolt shank to the thread must be optimized. Stress reduction...

  12. MONOTONIC AND CYCLIC LOADING SIMULATION OF STRUCTURAL STEELWORK BEAM TO COLUMN BOLTED CONNECTIONS WITH CASTELLATED BEAM

    Directory of Open Access Journals (Sweden)

    SAEID ZAHEDI VAHID

    2013-08-01

    Full Text Available Recently steel extended end plate connections are commonly used in rigid steel frame due to its good ductility and ability for energy dissipation. This connection system is recommended to be widely used in special moment-resisting frame subjected to vertical monotonic and cyclic loads. However improper design of beam to column connection can leads to collapses and fatalities. Therefore extensive study of beam to column connection design must be carried out, particularly when the connection is exposed to cyclic loadings. This paper presents a Finite Element Analysis (FEA approach as an alternative method in studying the behavior of such connections. The performance of castellated beam-column end plate connections up to failure was investigated subjected to monotonic and cyclic loading in vertical and horizontal direction. The study was carried out through a finite element analysis using the multi-purpose software package LUSAS. The effect of arranging the geometry and location of openings were also been investigated.

  13. Experimental Study on Bond-Slip Behavior of Bamboo Bolt-Modified Slurry Interface under Pull-Out Load

    Directory of Open Access Journals (Sweden)

    Wei Lu

    2018-01-01

    Full Text Available This paper presents an analysis of bamboo bolt-modified slurry interfaces based on 26 in situ axial pull-out tests intended to highlight the mechanical behavior of interface under a fracture mode. Three impact factors are analyzed: anchorage length, bolt diameter, and bolt hole diameter, using the same materials of bamboo and modified slurry. The result shows that the interface between the bamboo bolt and anchoring agent is the control interface of an anchorage system, and the local behavior of the interface involves four stages: elastic, soften, friction, and decoupling. Distribution law and change trend of slippage, stress, and strain of anchoring interface along with the axial direction of an anchor bolt were analyzed. The result shows that there is effective anchoring length limit in this kind of interface, and that the complete decoupling phenomenon should not be neglected. Through a comparative analysis of the existing bond-slip model and interface bond-slip curve, and considering the correspondence of the strain-slip curve and trilinear bond-slip model simultaneously, a modified trilinear bond-slip model has been proposed. The friction section of this model is limited, and shearing stress in the complete decoupling section is zero.

  14. Anchor Bolt Position in Base Plate In Terms Of T and J Anchor Bolt

    Directory of Open Access Journals (Sweden)

    b Osman Mohamad Hairi

    2017-01-01

    Full Text Available Generally, L anchor bolt system has been used for a long period of time in construction industry as one of the distributing load structures. However, there are some weaknesses in L anchor bolt which may straighten and pullup when charged with tensile load. Current practices prefer to use other types of anchor bolt systems, such as headed studs anchor bolt system to replace the L anchor bolt design. There has been lack of studies to prove that it is more effective in terms of performance. A new T anchor bolt which was basically modified from headed studs anchor bolt was proposed in this study to compare its performance of tensile loading in concrete failure to typical L design. This study aims to determine whether the T anchor bolt system gives better performance as compared to an L anchor bolt system. The performance was rated based on tensile loading on concrete failure pattern. A pullout test was conducted on two different anchor bolt systems, namely L and T. The anchor bolt embedded depth, h in concrete were varied according to their hook or bend radius. Each sample was repeated twice. There were totally eight samples. The hook or bend radius used were 50 mm and 57.5 mm for sample L1 and L2, respectively. 90-degree bend were used on sample T1 and T2. Based on test results, it can be seen that the performance of concrete failure pattern under tensile load on both L and T anchor bolt design samples with 200 mm embedment depth was better than deeper embedment depth of 230 mm. But the L anchor bolt design gives the best results as compared to T design. Although T anchor bolt design shows higher resistance before first bond failure to the concrete sample. T anchor bolt was analysed and needed deeper embedment depth to allow formation of cone pull-out shape to acquire better performance.

  15. Stress analysis of closure bolts for shipping casks

    International Nuclear Information System (INIS)

    Mok, G.C.; Fischer, L.E.; Hsu, S.T.

    1993-01-01

    This report specifies the requirements and criteria for stress analysis of closure bolts for shipping casks containing nuclear spent fuels or high level radioactive materials. The specification is based on existing information conceming the structural behavior, analysis, and design of bolted joints. The approach taken was to extend the ASME Boiler and Pressure Vessel Code requirements and criteria for bolting analysis of nuclear piping and pressure vessels to include the appropriate design and load characteristics of the shipping cask. The characteristics considered are large, flat, closure lids with metal-to-metal contact within the bolted joint; significant temperature and impact loads; and possible prying and bending effects. Specific formulas and procedures developed apply to the bolt stress analysis of a circular, flat, bolted closure. The report also includes critical load cases and desirable design practices for the bolted closure, an in-depth review of the structural behavior of bolted joints, and a comprehensive bibliography of current information on bolted joints

  16. The Ilizarov external fixator: what remains of the wire pretension after dynamic loading?

    NARCIS (Netherlands)

    Renard, A.J.S.; Schutte, B.G.; Verdonschot, N.J.J.; Kampen, A. van

    2005-01-01

    BACKGROUND: Maintenance of wire pretension in an Ilizarov external fixator is dependent on the torque applied to the fixation bolts. We therefore measured immediately after surgery the clinically applied torques. The median value was only 10 N m (range 8-14N m). We wondered whether this value is

  17. Effects of External Loads on Human Head Movement Control Systems

    Science.gov (United States)

    Nam, M. H.; Choi, O. M.

    1984-01-01

    The central and reflexive control strategies underlying movements were elucidated by studying the effects of external loads on human head movement control systems. Some experimental results are presented on dynamic changes weigh the addition of aviation helmet (SPH4) and lead weights (6 kg). Intended time-optimal movements, their dynamics and electromyographic activity of neck muscles in normal movements, and also in movements made with external weights applied to the head were measured. It was observed that, when the external loads were added, the subject went through complex adapting processes and the head movement trajectory and its derivatives reached steady conditions only after transient adapting period. The steady adapted state was reached after 15 to 20 seconds (i.e., 5 to 6 movements).

  18. Evaluation of the Match External Load in Soccer: Methods Comparison.

    Science.gov (United States)

    Castagna, Carlo; Varley, Matthew; Póvoas, Susana C A; D'Ottavio, Stefano

    2017-04-01

    To test the interchangeability of 2 match-analysis approaches for external-load detection considering arbitrary selected speeds and metabolic power (MP) thresholds in male top-level soccer. Data analyses were performed considering match physical performance of 60 matches (1200 player cases) of randomly selected Spanish, German, and English first-division championship matches (2013-14 season). Match analysis was performed with a validated semiautomated multicamera system operating at 25 Hz. During a match, players covered 10,673 ± 348 m, of which 1778 ± 208 m and 2759 ± 241 m were performed at high intensity, as measured using speed (≥16 km/h, HI) and metabolic power (≥20 W/kg, MPHI) notations. High-intensity notations were nearly perfectly associated (r = .93, P Player high-intensity decelerations (≥-2 m/s 2 ) were very largely associated with MPHI (r = .73, P physical match-analysis methods can be independently used to track match external load in elite-level players. However, match-analyst decisions must be based on use of a single method to avoid bias in external-load determination.

  19. An Application of Retroduction to Analyzing and Testing the Backing off of Nuts and Bolts During Dynamic Loading

    Science.gov (United States)

    Kerley, James J.

    1987-01-01

    The method of retroduction, adapted from the doctoral thesis of Dr. A. Croce, relies on a process of dialectic questioning that begins with the information sought, proceeds to Given items (either in the form of dimensions or limits of research). and to Known mathematical forms of analysis in design or to principles of study in research. Finally, analysis and synthesis are used to abstract the dielectic questions and to arrive at the information desired. This method is used to solve the engineering design problem of a beam and to determine why bolts and nuts vibrate apart. Both mathematical analysis and dialectic logical analysis are utilized. Results are provided of tests conducted to check the retroductive study of why and how nuts back off.

  20. Optimal tightening process of bolted joints

    Directory of Open Access Journals (Sweden)

    Monville Jean-Michel

    2016-01-01

    Full Text Available Threaded fasteners were developed long time (let’s remember that Archimedes – 287-212 BC – invented the water screw. Nowadays, bolted joints are used in almost all sectors of the industry. But in spite of having been an important machine part for centuries, problems may be encountered with them. They are so common that they are taken for granted and too often, not analyzed as deeply as it should be. The wrong tightening is one of the most frequent causes of ductile rupture and by far the most frequent cause of fatigue failure. The tightening operation is never easy. It is necessary to pay particular attention to the choice of the tightening tool, the process and the control method. The tightening operation may itself cause damage on parts. The tightening load must not be too low, or excessive or not equally distributed among the bolts. These three defects can even be made on the same bolted joint! This impacts badly the performance of the assembly and leads to a shorter lifespan. If insufficient precautions are taken, the real tightening preload on all the bolts will not fit well with the requirements and would be badly distributed. Consequently, the practical conditions are quite different from the hypothesizes which are taken for the initial calculations (analytics or FEM at the design stage. Thus, the results of the calculations of bolted joints cannot be considered as accurate and reliable. Practically, there are several means to tighten a bolt. The two ways most frequently used are torque wrench and hydraulic bolt tensioner. Torque wrench involves exerting a torque to the bolt head or the nut. Hydraulic bolt tensioner applies a traction load directly on the bolt. It is well known that bolt tensioners give better accuracy and homogeneity in the final tightening load than the torque method, but the tension load applied with the tensioner must be higher than the final remaining tightening load. So, the paper focusses on the hydraulic

  1. Dynamic analysis of scraper conveyor operation with external loads

    Directory of Open Access Journals (Sweden)

    Świder Jerzy

    2017-01-01

    Full Text Available A load to an armoured face conveyor (AFC during coal mining is changeable and very difficult or even impossible to be predicted. Changes of the load to the upper scraper chain affect the load of the driving motor and generate changes in a scraper chain tension. Impact of increasing the external load to the upper scraper chain on the operation of electric motors and on the scraper chain tension is presented. The developed numerical model of the Rybnik 850 conveyor enabled identifying the places of the scraper chain high tension or places of its loosening. An impact of changing frequency of driving motor voltage on AFC’s operational conditions was tested and analysed using the AFC’s numerical model. During tests, tension of the scraper chain on the discharge end and the return end was recorded. High tension of the scraper chain and its loosening during the changeable load were also recorded on upward and downward transportation of run-of-mine material.

  2. Effect of fiberglass reinforcement on the behavior of bolted wood connections

    Science.gov (United States)

    Lawrence A. Soltis; Robert J. Ross; Daniel E. Windorski

    1997-01-01

    Bolted connections often fail by a shear plug or by splitting beneath the bolt caused by tension perpendicular-to-grain stress as the bolt wedges its way through the wood. Preventing this type of failure enhances both the capacity and reliability of bolted connections. This research investigated the use of fiberglass reinforcement to enhance the load-carrying capacity...

  3. A new energy-absorbing bolt for rock support in high stress rock masses

    Energy Technology Data Exchange (ETDEWEB)

    Charlie Chunlin Li [Norwegian University of Science and Technology (NTNU) (Norway)

    2010-04-15

    An energy-absorbing rock support device, called a D bolt, has been recently developed to counteract both burst-prone and squeezing rock conditions that occur during underground excavation. The bolt is a smooth steel bar with a number of anchors along its length. The anchors are firmly fixed within a borehole using either cement grout or resin, while the smooth sections of the bolt between the anchors may freely deform in response to rock dilation. Failure of one section does not affect the reinforcement performance of the other sections. The bolt is designed to fully use both the strength and the deformation capacity of the bolt material along the entire length. The bolt has large load-bearing and deformation capacities. Static pull tests and dynamic drop tests show that the bolt length elongates by 14-20% at a load level equal to the strength of the bolt material, thereby absorbing a large amount of energy. The impact average load of a 20 mm D bolt is 200-230 kN, with only a small portion of the load transferred to the bolt plate. The cumulative dynamic energy absorption of the bolt is measured to be 47 kJ/m. D bolts were tested in three deep mines. Filed measurements show that D bolts are loaded less than rebar bolts. This paper presents the layout and principle of the D bolt, and corresponding results from static, dynamic, and field tests.

  4. A 3D regression surface for the room temperature tightness gasket data reduction and bolt load design

    International Nuclear Information System (INIS)

    Jolly, Pascal; Marchand, Luc

    2008-01-01

    The purpose of the present work is to propose a new approach for modelling the tightness behaviour of the gaskets used in bolted flange joints. This new approach consists of developing a mathematical model for a three-dimensional (3D) representation of the gasket tightness performance. Rather than considering a 2D graph for characterizing the complete gasket behaviour, a third axis is added to the S g vs. Tp plot to dissociate the unloading cycles from initial gasket tightening. This leads to the definition of a surface that is represented by a simple polynomial equation that contains six coefficients that are determined by a simple regression calculation. In the first part of the paper, the new approach is tested through a database of 406 room temperature tightness (ROTT) tests performed on different gasket styles. Then, a statistical analysis of the predictions made with the new model demonstrates its ability to predict gasket leak rates much more accurately than it was previously possible with the gasket constants derived from the ROTT Draft 9 or 10 methods. It is also demonstrated that the new approach can be used to model successfully complex gasket behaviours such as the tightness hardening phenomenon. Secondly, the effect of gas pressure change on the leak rate is analysed. It turns out that at high gasket stresses, the actual scheme of the ROTT tests may not allow enough time for reaching a stabilized leak rate value because of a transitory time effect in the porous structure of gaskets. Then, in order to evaluate the characteristic waiting period (dwell time) before a stabilized flow rate is achieved following a change in the gas pressure level, a simple phenomenological analysis of the flow is performed

  5. Piezoelectric Bolt Breakers and Bolt Fatigue Testers

    Science.gov (United States)

    Sherrit, Stewart; Badescu, Mircea; Bar-Cohen, Yoseph; Barengoltz, Jack; Heckman, Vanessa

    2008-01-01

    A proposed family of devices for inducing fatigue in bolts in order to break the bolts would incorporate piezoelectric actuators into resonant fixtures as in ultrasonic/ sonic drills/corers and similar devices described in numerous prior NASA Tech Briefs articles. These devices were originally intended primarily for use as safer, more-reliable, more-versatile alternatives to explosive bolts heretofore used to fasten spacecraft structures that must subsequently be separated from each other quickly on command during flight. On Earth, these devices could be used for accelerated fatigue testing of bolts. Fatigue theory suggests that a bolt subjected to both a constant-amplitude dynamic (that is, oscillatory) stress and a static tensile stress below the ultimate strength of the bolt material will fail faster than will a bolt subjected to only the dynamic stress. This suggestion would be applied in a device of the proposed type. The device would be designed so that the device and the bolt to be fatigue-tested or broken would be integral parts of an assembly (see figure). The static tension in the tightened bolt would apply not only the clamping force to hold the joined structures (if any) together but also the compression necessary for proper operation of the piezoelectric actuators as parts of a resonant structural assembly. The constant-amplitude dynamic stress would be applied to the bolt by driving the piezoelectric actuators with a sinusoidal voltage at the resonance frequency of longitudinal vibration of the assembly. The amplitude of the excitation would be made large enough so that the vibration would induce fatigue in the bolt within an acceptably short time. In the spacecraft applications or in similar terrestrial structural-separation applications, devices of the proposed type would offer several advantages over explosive bolts: Unlike explosive bolts, the proposed devices would be reusable, could be tested before final use, and would not be subject to

  6. Vibration condition monitoring of planetary gearbox under varying external load

    Energy Technology Data Exchange (ETDEWEB)

    Bartelmus, W.; Zimroz, R. [Wroclaw University of Technology, Wroclaw (Poland)

    2009-01-15

    The paper shows that for condition monitoring of planetary gearboxes it is important to identify the external varying load condition. In the paper, systematic consideration has been taken of the influence of many factors on the vibration signals generated by a system in which a planetary gearbox is included. These considerations give the basis for vibration signal interpretation, development of the means of condition monitoring, and for the scenario of the degradation of the planetary gearbox. Real measured vibration signals obtained in the industrial environment are processed. The signals are recorded during normal operation of the diagnosed objects, namely planetary gearboxes, which are a part of the driving system used in a bucket wheel excavator, used in lignite mines. It has been found that the most important factor of the proper planetary gearbox condition is connected with perturbation of arm rotation, where an arm rotation gives rise to a specific vibration signal whose properties are depicted by a short-time Fourier transform (STFT) and Wigner-Ville distribution presented as a time-frequency map. The paper gives evidence that there are two dominant low-frequency causes that influence vibration signal modulation, i.e. the varying load, which comes from the nature of the bucket wheel digging process, and the arm/carrier rotation. These two causes determine the condition of the planetary gearboxes considered.

  7. Small-Bolt Torque-Tension Tester

    Science.gov (United States)

    Posey, Alan J.

    2009-01-01

    The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.

  8. Enhancement of tendon–bone healing via the combination of biodegradable collagen-loaded nanofibrous membranes and a three-dimensional printed bone-anchoring bolt

    Directory of Open Access Journals (Sweden)

    Chou YC

    2016-08-01

    Full Text Available Ying-Chao Chou,1,2 Wen-Lin Yeh,2 Chien-Lin Chao,1 Yung-Heng Hsu,1,2 Yi-Hsun Yu,1,2 Jan-Kan Chen,3 Shih-Jung Liu1,2 1Department of Mechanical Engineering, Chang Gung University, 2Department of Orthopedic Surgery, Chang Gung Memorial Hospital, 3Department of Physiology and Pharmacology, Chang Gung University, Taoyuan, Taiwan Abstract: A composite biodegradable polymeric model was developed to enhance tendon graft healing. This model included a biodegradable polylactide (PLA bolt as the bone anchor and a poly(D,L-lactide-co-glycolide (PLGA nanofibrous membrane embedded with collagen as a biomimic patch to promote tendon–bone interface integration. Degradation rate and compressive strength of the PLA bolt were measured after immersion in a buffer solution for 3 months. In vitro biochemical characteristics and the nanofibrous matrix were assessed using a water contact angle analyzer, pH meter, and tetrazolium reduction assay. In vivo efficacies of PLGA/collagen nanofibers and PLA bolts for tendon–bone healing were investigated on a rabbit bone tunnel model with histological and tendon pullout tests. The PLGA/collagen-blended nanofibrous membrane was a hydrophilic, stable, and biocompatible scaffold. The PLA bolt was durable for tendon–bone anchoring. Histology showed adequate biocompatibility of the PLA bolt on a medial cortex with progressive bone ingrowth and without tissue overreaction. PLGA nanofibers within the bone tunnel also decreased the tunnel enlargement phenomenon and enhanced tendon–bone integration. Composite polymers of the PLA bolt and PLGA/collagen nanofibrous membrane can effectively promote outcomes of tendon reconstruction in a rabbit model. The composite biodegradable polymeric system may be useful in humans for tendon reconstruction. Keywords: polylactide–polyglycolide nanofibers, PLGA, collagen, 3D printing, polylactide, PLA, bone-anchoring bolts, tendon healing

  9. Bolt Stress Monitor

    Science.gov (United States)

    1978-01-01

    In photo, an engineer is using a new Ultrasonic Bolt Stress Monitor developed by NASA's Langley Research Center to determine whether a bolt is properly tightened. A highly accurate device, the monitor is an important tool in construction of such structures as pressure vessels, bridges and power plants, wherein precise measurement of the stress on a tightened bolt is critical. Overtightened or undertightened bolts can fail and cause serious industrial accidents or costly equipment break-downs. There are a number of methods for measuring bolt stress. Most widely used and least costly is the torque wrench, which is inherently inaccurate; it does not take into account the friction between nut and bolt, which has an influence on stress. At the other end of the spectrum, there are accurate stress-measuring systems, but they are expensive and not portable. The battery-powered Langley monitor fills a need; it is inexpensive, lightweight, portable and extremely accurate because it is not subject to friction error. Sound waves are transmitted to the bolt and a return signal is received. As the bolt is tightened, it undergoes changes in resonance due to stress, in the manner that a violin string changes tone when it is tightened. The monitor measures the changes in resonance and provides a reading of real stress on the bolt. The device, patented by NASA, has aroused wide interest and a number of firms have applied for licenses to produce it for the commercial market.

  10. Fatigue-Arrestor Bolts

    Science.gov (United States)

    Onstott, Joseph W.; Gilster, Mark; Rodriguez, Sergio; Larson, John E.; Wickham, Mark D.; Schoonover, Kevin E.

    1995-01-01

    Bolts that arrest (or, more precisely, retard) onset of fatigue cracking caused by inelastic strains developed. Specifically developed to be installed in flange holes of unrestrained rocket engine nozzle. Fanges sometimes used to bolt nozzle to test stand; however, when rocket engine operated without this restraint, region around bolt holes experience severe inelastic strains causing fatigue cracking. Interference fits introduce compressive preloads that retard fatigue by reducing ranges of strains. Principle of these fatigue-arrestor bolts also applicable to holes in plates made of other materials and/or used for different purposes.

  11. Effect of External Loading on Force and Power Production During Plyometric Push-ups.

    Science.gov (United States)

    Hinshaw, Taylour J; Stephenson, Mitchell L; Sha, Zhanxin; Dai, Boyi

    2018-04-01

    Hinshaw, TJ, Stephenson, ML, Sha, Z, and Dai, B. Effect of external loading on force and power production during plyometric push-ups. J Strength Cond Res 32(4): 1099-1108, 2018-One common exercise to train upper-body strength and power is the push-up. Training at the loads that would produce the greatest power is an effective way to increase peak power. The purpose of the current study was to quantify the changes in peak force, peak power, and peak velocity among a modified plyometric push-up and plyometric push-ups with or without external loading in physically active young adults. Eighteen male and 17 female participants completed 4 push-ups: (a) modified plyometric push-up on the knees, (b) plyometric push-up without external loading, (c) plyometric push-up with an external load of 5% of body weight, and (d) plyometric push-up with an external load of 10% of body weight. Two force platforms were set up to collect vertical ground reaction forces at the hands and feet. The modified plyometric push-up demonstrated the lowest force, power, and velocity (5.4≥ Cohen's dz ≥1.2). Peak force and force at peak velocity increased (3.8≥ Cohen's dz ≥0.3) and peak velocity and velocity at peak power decreased (1.4≥ Cohen's dz ≥0.8) for the push-up without external loading compared with the 2 push-ups with external loading. No significant differences were observed for peak power among the push-ups with or without external loading (0.4≥ Cohen's dz ≥0.1). Although peak power is similar with or without external loading, push-ups without external loading may be more beneficial for a quick movement, and push-ups with external loading may be more beneficial for a greater force production.

  12. On analysis and redesign of bolted L-flanged connections

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2017-01-01

    and the tensile force in the bolt. In the literature and also in standards,different models are presented for this important non-linear response. In the present paper, a simplified expression for the non-linear force response is presented based on finite element calculations using contact analysis. The L......-flange connection is in essence a bad design because it leads to a non-optimal ratio between external force and bolt force. Furthermore,bolt bending results in an even higher bolt stress resulting in a reduction of strength. The present paper presents simple modifications of the L-flange design that considerably...

  13. Hip abduction strength training in the clinical setting: with or without external loading?

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, T; Petersen, Jesper

    2010-01-01

    only the weight of the leg as resistance, whereas training with external loading was performed with a relative load corresponding to 10 repetition maximum. Hip abduction strength was measured pre- and post-intervention. Isometric and eccentric hip abduction strength of the trained leg increased after......The side-lying hip abduction exercise is one of the most commonly used exercises in rehabilitation to increase hip abduction strength, and is often performed without external loading. The aim of this study was to compare the effect of 6 weeks of side-lying hip abduction training, with and without...... external loading, on hip abduction strength in healthy subjects. Thirty-one healthy, physically active men and women were included in a randomised controlled trial and allocated to side-lying hip abduction training, with or without external loading. Training without external loading was performed using...

  14. The Influence of External Load on Quadriceps Muscle and Tendon Dynamics during Jumping.

    Science.gov (United States)

    Earp, Jacob E; Newton, Robert U; Cormie, Prue; Blazevich, Anthony J

    2017-11-01

    Tendons possess both viscous (rate-dependent) and elastic (rate-independent) properties that determine tendon function. During high-speed movements external loading increases both the magnitude (FT) and rate (RFDT) of tendon loading. The influence of external loading on muscle and tendon dynamics during maximal vertical jumping was explored. Ten resistance-trained men performed parallel-depth, countermovement vertical jumps with and without additional load (0%, 30%, 60%, and 90% of maximum squat lift strength), while joint kinetics and kinematics, quadriceps tendon length (LT) and patellar tendon FT and RFDT were estimated using integrated ultrasound, motion analysis and force platform data and muscle tendon modelling. Estimated FT and RFDT, but not peak LT, increased with external loading. Temporal comparisons between 0% and 90% loads revealed that FT was greater with 90% loading throughout the majority of the movement (11%-81% and 87%-95% movement duration). However, RFDT was greater with 90% load only during the early movement initiation phase (8%-15% movement duration) but was greater in the 0% load condition later in the eccentric phase (27%-38% movement duration). LT was longer during the early movement (12%-23% movement duration) but shorter in the late eccentric and early concentric phases (48%-55% movement duration) with 90% load. External loading positively influenced peak FT and RFDT but tendon strain appeared unaffected, suggesting no additive effect of external loading on patellar tendon lengthening during human jumping. Temporal analysis revealed that external loading resulted in a large initial RFDT that may have caused dynamic stiffening of the tendon and attenuated tendon strain throughout the movement. These results suggest that external loading influences tendon lengthening in both a load- and movement-dependent manner.

  15. Calculation of parameters of combined frame and roof bolting

    Science.gov (United States)

    Ivanov, S. I.; Titov, N. V.; Privalov, A. A.; Trunov, I. T.; Sarychev, V. I.

    2017-10-01

    The paper presents the method of calculation of the combined frame and roof bolting. Recommendations on providing joint operation of roof bolting with steel support frames are given. Graphs for determining standard rock movement, as well as for defining proof load on the yielding support, were developed.

  16. Comparative study of bolt spacing formulas used in bolted joint designs

    International Nuclear Information System (INIS)

    Bouzid, Abdel-Hakim

    2014-01-01

    Bolted flange joints are the most popular type of connection between pressure vessels and piping equipment. They are very attractive type of connection because they are simple to mount and offer the possibility of disassembly. However, they are very complex structures to design and analyze and often result in leakage failure. One of the raisons is the loss of tightness that results from the uneven distribution of the gasket contact stresses in the radial and circumferential direction. Many factors contribute to such a failure; bolt load non-uniformity, inadequate flange to gasket stiffness, inappropriate bolt spacing requirements or a combinations of some of these. The variation of the contact stress in the circumferential direction between any two bolts is dictated by bolt spacing. This paper is an extension of the work in which the more accurate analytical solution based on the theory of circular beams resting on a linear elastic foundation is used to validate some existing flange bolt spacing formulas and in particular the TEMA formula, Robert's formula and the one recently developed by Koves. The relationship between bolt spacing and the gasket compression modulus, flange thickness and size is deduced from an analysis that considers a maximum tolerated gasket contact stress difference obtained at the bolt and between two bolts. Comparison between these different methods is also provided. - Highlights: • Gasket stress is estimated using theory of circular beams on linear elastic foundation. • TEMA, Robert's and Koves' formulas are compared against the developed model. • A recommendation is made to use Koves' formula for design. • Use a correction factor of 1/(1-ν 2 ) to accommodate small diameter flanges

  17. The relationships between internal and external training load models during basketball training.

    Science.gov (United States)

    Scanlan, Aaron T; Wen, Neal; Tucker, Patrick S; Dalbo, Vincent J

    2014-09-01

    The present investigation described and compared the internal and external training loads during basketball training. Eight semiprofessional male basketball players (mean ± SD, age: 26.3 ± 6.7 years; stature: 188.1 ± 6.2 cm; body mass: 92.0 ± 13.8 kg) were monitored across a 7-week period during the preparatory phase of the annual training plan. A total of 44 total sessions were monitored. Player session ratings of perceived exertion (sRPE), heart rate, and accelerometer data were collected across each training session. Internal training load was determined using the sRPE, training impulse (TRIMP), and summated-heart-rate-zones (SHRZ) training load models. External training load was calculated using an established accelerometer algorithm. Pearson product-moment correlations with 95% confidence intervals (CIs) were used to determine the relationships between internal and external training load models. Significant moderate relationships were observed between external training load and the sRPE (r42 = 0.49, 95% CI = 0.23-0.69, p external training load and the SHRZ model (r42 = 0.61, 95% CI = 0.38-0.77, p internal and external training load models, the magnitude of the correlations and low commonality suggest that internal training load models measure different constructs of the training process than the accelerometer training load model in basketball settings. Basketball coaching and conditioning professionals should not assume a linear dose-response between accelerometer and internal training load models during training and are recommended to combine internal and external approaches when monitoring training load in players.

  18. Investigation of Reliabilities of Bolt Distances for Bolted Structural Steel Connections by Monte Carlo Simulation Method

    Directory of Open Access Journals (Sweden)

    Ertekin Öztekin Öztekin

    2015-12-01

    Full Text Available Design of the distance of bolts to each other and design of the distance of bolts to the edge of connection plates are made based on minimum and maximum boundary values proposed by structural codes. In this study, reliabilities of those distances were investigated. For this purpose, loading types, bolt types and plate thicknesses were taken as variable parameters. Monte Carlo Simulation (MCS method was used in the reliability computations performed for all combination of those parameters. At the end of study, all reliability index values for all those distances were presented in graphics and tables. Results obtained from this study compared with the values proposed by some structural codes and finally some evaluations were made about those comparisons. Finally, It was emphasized in the end of study that, it would be incorrect of the usage of the same bolt distances in the both traditional designs and the higher reliability level designs.

  19. Image Registration-Based Bolt Loosening Detection of Steel Joints

    Science.gov (United States)

    2018-01-01

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts. PMID:29597264

  20. Image Registration-Based Bolt Loosening Detection of Steel Joints.

    Science.gov (United States)

    Kong, Xiangxiong; Li, Jian

    2018-03-28

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts.

  1. Monitoring external and internal loads of brazilian soccer referees during official matches.

    Science.gov (United States)

    Costa, Eduardo C; Vieira, Caio M A; Moreira, Alexandre; Ugrinowitsch, Carlos; Castagna, Carlo; Aoki, Marcelo S

    2013-01-01

    This study aimed to assess the external and internal loads of Brazilian soccer referees during official matches. A total of 11 field referees (aged 36.2 ± 7.5 years) were monitored during 35 matches. The external (distance covered, mean and maximal speed) and internal load parameters (session ratings of perceived exertion [RPE] training load [TL], Edwards' TL, and time spent in different heart rate [HR] zones) were assessed in 3-4 matches per referee. External load parameters were measured using a wrist Global Positioning System (GPS) receiver. No differences in distance covered (5.219 ± 205 vs. 5.230 ± 237 m) and maximal speed (19.3 ± 1.0 vs. 19.4 ± 1.4 km·h(-1)) were observed between the halves of the matches (p > 0.05). However, the mean speed was higher in the first half of the matches (6.6 ± 0.4 vs. 6.4 ± 0.3 km·h(-1)) (p external and internal load demands during official matches. The portable GPS/HR monitors and session RPE method can provide relevant information regarding the magnitude of the physiological strain during official matches. Key PointsHigh external and internal loads were imposed on Brazilian soccer referees during official matches.There was a high positive correlation between a subjective marker of internal load (session RPE) and parameters of external load (distance covered between 90-100% of HRmax and maximal speed).There was a high positive correlation between session RPE method and Edwards' method.Session RPE seems to be a reliable marker of internal load.The portable GPS/HR monitors and the session RPE method can provide relevant information regarding the magnitude of external and internal loads of soccer referees during official matches.

  2. Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

    Science.gov (United States)

    Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2015-08-01

    The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

  3. Nonlinear ultrasonic imaging method for closed cracks using subtraction of responses at different external loads.

    Science.gov (United States)

    Ohara, Yoshikazu; Horinouchi, Satoshi; Hashimoto, Makoto; Shintaku, Yohei; Yamanaka, Kazushi

    2011-08-01

    To improve the selectivity of closed cracks for objects other than cracks in ultrasonic imaging, we propose an extension of a novel imaging method, namely, subharmonic phased array for crack evaluation (SPACE) as well as another approach using the subtraction of responses at different external loads. By applying external static or dynamic loads to closed cracks, the contact state in the cracks varies, resulting in an intensity change of responses at cracks. In contrast, objects other than cracks are independent of external load. Therefore, only cracks can be extracted by subtracting responses at different loads. In this study, we performed fundamental experiments on a closed fatigue crack formed in an aluminum alloy compact tension (CT) specimen using the proposed method. We examined the static load dependence of SPACE images and the dynamic load dependence of linear phased array (PA) images by simulating the external loads with a servohydraulic fatigue testing machine. By subtracting the images at different external loads, we show that this method is useful in extracting only the intensity change of responses related to closed cracks, while canceling the responses of objects other than cracks. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Russian standards and design practice of ensuring NPP reliability under severe external loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Birbraer, A N [St. Petersburg Research and Design Institute Atomenergoproject, St. Petersburt (Russian Federation)

    1993-07-01

    Russian Standards and design practice of ensuring NPP reliability under severe external loading conditions are described. The main attention is paid to the seismic design requirements. Explosions, aircraft impact, and tornado are briefly examined too (author)

  5. External representation of argumentation in CSCL and the management of cognitive load

    NARCIS (Netherlands)

    Bruggen, J.M.; Kirschner, P.A.; Jochems, W.

    2002-01-01

    Computer-supported collaborative learning (CSCL) environments, particularly environments where students share external representations, are discussed as an interesting area for the application of cognitive load theory (CLT). CSCL environments share a number of characteristics that will induce

  6. Russian standards and design practice of ensuring NPP reliability under severe external loading conditions

    International Nuclear Information System (INIS)

    Birbraer, A.N.

    1993-01-01

    Russian Standards and design practice of ensuring NPP reliability under severe external loading conditions are described. The main attention is paid to the seismic design requirements. Explosions, aircraft impact, and tornado are briefly examined too (author)

  7. External Coulomb-Friction Damping For Hydrostatic Bearings

    Science.gov (United States)

    Buckmann, Paul S.

    1992-01-01

    External friction device damps vibrations of shaft and hydrostatic ring bearing in which it turns. Does not rely on wear-prone facing surfaces. Hydrostatic bearing ring clamped in radially flexing support by side plates clamped against radial surfaces by spring-loaded bolts. Plates provide friction against radial motions of shaft.

  8. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  9. Application of Long Expansion Rock Bolt Support in the Underground Mines of Legnica-Głogów Copper District

    Science.gov (United States)

    Skrzypkowski, Krzysztof; Korzeniowski, Waldemar; Zagórski, Krzysztof; Dudek, Piotr

    2017-09-01

    excavations, and it is increasingly frequently used to reinforce roofs and in rebuilding the underground mines of KGHM Polish Copper S.A. In order to conduct the laboratory tests that are most suitable for the mine conditions, and yet are carried out on a laboratory test facility, the Authors used a steel cylinder with an external diameter of 102 mm and a length of 600 mm, which was filled with a core of rock (dolomite) from the roofs of the mine workings. In addition the maximum load that took over the bolt support made of rods and connected with sleeves was determined. For the initial tension, the elastic and plastic range of the maximal displacements, which were measured by the rope encoder, were determined. The statical tests of the expansion rock bolt support were carried out at the laboratory of the Department of Underground Mining in simulated mine conditions. The test facility enables the study of the long bolt rods on a geometric scale of 1:1 for the different ways of fixing. The aim of the laboratory research was to obtain the stress-strain characteristics, of the long expansion rock bolt support with a steel bearing plate and a plate printed on a 3D printer.

  10. Stability Study of Anthropomorphic Robot Antares under External Load Action

    Science.gov (United States)

    Kodyakov, A. S.; Pavlyuk, N. A.; Budkov, V. Yu; Prakapovich, R. A.

    2017-01-01

    The paper presents the study of the behavior of the major structural elements of the lower limbs of anthropomorphic robot Antares under the influence of different types of loads (torsion, fracture). We have determined the required values for actuators torques for motion of the robot in space. The maximum values of torques are 5 Nm and 5.2 Nm respectively, and are able to withstand the upper and lower leg structures.

  11. Effect of external viscous load on head movement

    Science.gov (United States)

    Nam, M.-H.; Lakshminarayanan, V.; Stark, L. W.

    1984-01-01

    Quantitative measurements of horizontal head rotation were obtained from normal human subjects intending to make 'time optimal' trajectories between targets. By mounting large, lightweight vanes on the head, viscous damping B, up to 15 times normal could be added to the usual mechanical load of the head. With the added viscosity, the head trajectory was slowed and of larger duration (as expected) since fixed and maximal (for that amplitude) muscle forces had to accelerate the added viscous load. This decreased acceleration and velocity and longer duration movement still ensued in spite of adaptive compensation; this provided evidence that quasi-'time optimal' movements do indeed employ maximal muscle forces. The adaptation to this added load was rapid. Then the 'adapted state' subjects produced changed trajectories. The adaptation depended in part on the differing detailed instructions given to the subjects. This differential adaptation provided evidence for the existence of preprogrammed controller signals, sensitive to intended criterion, and neurologically ballistic or open loop rather than modified by feedback from proprioceptors or vision.

  12. Experimental study on birefringence effect in high-tension bolts

    International Nuclear Information System (INIS)

    Kim, No You; Lee, Sang Soon; Jang, Kyung Young

    2005-01-01

    Bolts widely used in machine parts and assemblies are pre-loaded to prevent the parts from separating and to maintain the strength of the assemblies. Conventional technique for measurement of this axial stress applied to bolts is torque meter, but it has two disadvantages. The first one is its inherent inaccuracy. The second is that the stress cannot be determined after assembly without twisting bolts. The most promising technique for measurement of the axial stress is the acousto-elasticity. In this study, a new acousto-elasticity technique based on birefringence principle is proposed and tested to measure the axial stress in bolts which uses two longitudinal and shear waves instead of two horizontally polarized shear waves. From experimental results, the difference between the longitudinal and shear wave velocity is shown to be linearly related to the applied stress and be able to be used effectively to monitor the axial stress in bolts.

  13. Bolting multicenter solutions

    Energy Technology Data Exchange (ETDEWEB)

    Bena, Iosif [Institut de Physique Théorique, Université Paris Saclay, CEA, CNRS, 91191 Gif-sur-Yvette Cedex (France); Bossard, Guillaume [Centre de Physique Théorique, Ecole Polytechnique, CNRS, Université Paris-Saclay, 91128 Palaiseau Cedex (France); Katmadas, Stefanos; Turton, David [Institut de Physique Théorique, Université Paris Saclay, CEA, CNRS, 91191 Gif-sur-Yvette Cedex (France)

    2017-01-30

    We introduce a solvable system of equations that describes non-extremal multicenter solutions to six-dimensional ungauged supergravity coupled to tensor multiplets. The system involves a set of functions on a three-dimensional base metric. We obtain a family of non-extremal axisymmetric solutions that generalize the known multicenter extremal solutions, using a particular base metric that introduces a bolt. We analyze the conditions for regularity, and in doing so we show that this family does not include solutions that contain an extremal black hole and a smooth bolt. We determine the constraints that are necessary to obtain smooth horizonless solutions involving a bolt and an arbitrary number of Gibbons-Hawking centers.

  14. The Fatigue Characteristics of Bolted Lap Joints of 24S-T Alclad Sheet Materials

    Science.gov (United States)

    1946-10-01

    extremely close bolt fits are needed to o%tain maximum life of bolt ~oint~ under repeated etreseeci. -. Szvzral ty~+?+s of bolt patterns hava been tegted...Memorial Institute on spec~meris of 0.102-i.nch sheet. In particular, figure 4 shows, on a load- life diagram, . results of tests Qn single-bolt...results of tests at the Univer- sity of’ il~~nols on single—bolt specimens, Tables 10 and 11 give reeults of tests, made at the U“ uiversity of Illino~8 , on

  15. Bolt and nut evaluator

    Science.gov (United States)

    Kerley, James J.; Burkhardt, Raymond; White, Steven

    1994-02-01

    A device for testing fasteners such as nuts and bolts is described which consists of a fixed base plate having a number of threaded and unthreaded holes of varying size for receiving the fasteners to be tested, a torque marking paper taped on top the fixed base plate for marking torque-angle indicia, a torque wrench for applying torque to the fasteners being tested, and an indicator for showing the torque applied to the fastener. These elements provide a low cost, nondestructive device for verifying the strength of bolts and nuts.

  16. Turbine casing bolts; a life assessment and bolt replacement strategy

    Energy Technology Data Exchange (ETDEWEB)

    Bulloch, J.H. [ESB, Power Generation, Dublin (Ireland)

    1998-12-31

    The present presentation describes a detailed study concerning the life assessment and replacement strategy of large turbine casing bolts in a 120 MW steam raising unit. After 122000 hours service, circa 1991/92, the Cr-Mo-V steel casing bolts, involving a total of 184 bolts, from two identical 120 MW units, termed Units 1 and 2, were examined to establish the extent of Reverse Temper Embrittlement, RTE, and creep damage suffered during service. The bolt replacement plans for the two units were as follows; Unit 1 bolts were completely replaced with new bolts while Unit 2 embrittled bolts were withdrawn from service and replaced with Non- Embrittled bolts from Unit 1; basically Unit 2 bolts were made up from a mixture of Unit 1 and 2 Non- Embrittled bolts which had been in service for 122000 hours. Remnant life assessments, concerning both embrittlement and creep damage aspects, were earned out on this series of easing bolts at service times 122000, 150000 and 200000 hours. These assessments involved the use of general embrittlement and creep damage laws which were empirically derived and concerned such parameters as microstructural grain size, bulk phosphorus content and accumulated service strain. (orig.) 7 refs.

  17. Turbine casing bolts; a life assessment and bolt replacement strategy

    Energy Technology Data Exchange (ETDEWEB)

    Bulloch, J H [ESB, Power Generation, Dublin (Ireland)

    1999-12-31

    The present presentation describes a detailed study concerning the life assessment and replacement strategy of large turbine casing bolts in a 120 MW steam raising unit. After 122000 hours service, circa 1991/92, the Cr-Mo-V steel casing bolts, involving a total of 184 bolts, from two identical 120 MW units, termed Units 1 and 2, were examined to establish the extent of Reverse Temper Embrittlement, RTE, and creep damage suffered during service. The bolt replacement plans for the two units were as follows; Unit 1 bolts were completely replaced with new bolts while Unit 2 embrittled bolts were withdrawn from service and replaced with Non- Embrittled bolts from Unit 1; basically Unit 2 bolts were made up from a mixture of Unit 1 and 2 Non- Embrittled bolts which had been in service for 122000 hours. Remnant life assessments, concerning both embrittlement and creep damage aspects, were earned out on this series of easing bolts at service times 122000, 150000 and 200000 hours. These assessments involved the use of general embrittlement and creep damage laws which were empirically derived and concerned such parameters as microstructural grain size, bulk phosphorus content and accumulated service strain. (orig.) 7 refs.

  18. Bolted flanged connections subjected to longitudinal bending moments

    International Nuclear Information System (INIS)

    Blach, A.E.

    1992-01-01

    Flanges in piping systems and also pressure vessel flanges on tall columns are often subjected to longitudinal bending moments of considerable magnitude, be it from thermal expansion stresses in piping systems or from wind or seismic loadings on tall vertical pressure vessels. Except for the ASME Code, Section III, Subsections NB, NC, and ND, other pressure vessel and piping codes do not contain design ASME Nuclear Power Plant Code (Section III), an empirical formula is given, expressing a longitudinal bending moment in bolted flanged connections in terms of an equivalent internal pressure to be added to the design pressure of the flange. In this paper, an attempt is made to analyse the stresses on flanges and bolting due to external bending moments and to compare flange thicknesses thus obtained with thicknesses required using the equivalent design pressure specified in Subsections NB, NC, and ND. A design method is proposed, based on analysis and experimental work, which may be suitable for flange bending moment analysis when the rules of the Nuclear Power Plant Code are not mandatory. (orig.)

  19. Structural integrity analysis of an INPP building under external loading

    International Nuclear Information System (INIS)

    Dundulis, G.; Karalevicius, R.; Uspuras, E.; Kulak, R.F.; Marchertas, A.

    2005-01-01

    After the terrorist attacks in New York and Washington D. C. using civil airplanes, the evaluation of civil airplane crashes into civil and NPP structures has become very important. The interceptions of many terrorists' communications reveal that the use of commandeered commercial aircraft is still a major part of their plans for destruction. Aircraft crash or other flying objects in the territory of the Ignalina Nuclear Power Plant (INPP) represents a concern to the plant. Aircraft traveling at high velocity have a destructive potential. The aircraft crash may damage the roof and walls of buildings, pipelines, electric motors, cases of power supplies, power cables of electricity transmission and other elements and systems, which are important for safety. Therefore, the evaluation of the structural response to an of aircraft crash is important and was selected for analysis. The structural integrity analysis due to the effects of an aircraft crash on an NPP building structure is the subject of this paper. The finite element method was used for the structural analysis of a typical Ignalina NPP building. The structural integrity analysis was performed for a portion of the ALS using the dynamic loading of an aircraft crash impact model. The computer code NEPTUNE was used for this analysis. The local effects caused by impact of the aircraft's engine on the building wall were evaluated independently by using an empirical formula. (authors)

  20. Recovery of Myocardial Kinematic Function without the Time History of External Loads

    Directory of Open Access Journals (Sweden)

    Zhang Heye

    2010-01-01

    Full Text Available A time-domain filtering algorithm is proposed to recover myocardial kinematic function using output-only measurements without the time history of external loads. The main contribution of this work is that the overall effect of all the external loads on the myocardium is treated as a random variable disturbed by the Gaussian white noise because the external loads of the myocardium are usually unknown in practical exercises. The kernel of our proposed algorithm is an iterative, multiframe, and sequential filtering procedure consisting of a Kalman filter and a least-squares filter. In our proposed implementation, the initial guess of myocardial kinematic function and residual innovation of all the state variables are first computed using a Kalman filter via state space equations only driven by the Gaussian white noise, and then the residual innovation is fed into a least-squares filter to estimate the total external loads of the myocardium. In the end, the initial guess of myocardial kinematic function is corrected using external loads provided by the least-squares filter. After the introduction of the whole structure of our algorithm, we demonstrate the ability of the framework on synthetic data and MR image sequences.

  1. Bolt beam propagation analysis

    Science.gov (United States)

    Shokair, I. R.

    BOLT (Beam on Laser Technology) is a rocket experiment to demonstrate electron beam propagation on a laser ionized plasma channel across the geomagnetic field in the ion focused regime (IFR). The beam parameters for BOLT are: beam current I(sub b) = 100 Amps, beam energy of 1--1.5 MeV (gamma =3-4), and a Gaussian beam and channel of radii r(sub b) = r(sub c) = 1.5 cm. The N+1 ionization scheme is used to ionize atomic oxygen in the upper atmosphere. This scheme utilizes 130 nm light plus three IR lasers to excite and then ionize atomic oxygen. The limiting factor for the channel strength is the energy of the 130 nm laser, which is assumed to be 1.6 mJ for BOLT. At a fixed laser energy and altitude (fixing the density of atomic oxygen), the range can be varied by adjusting the laser tuning, resulting in a neutralization fraction axial profile of the form: f(z) = f(sub 0) e(exp minus z)/R, where R is the range. In this paper we consider the propagation of the BOLT beam and calculate the range of the electron beam taking into account the fact that the erosion rates (magnetic and inductive) vary with beam length as the beam and channel dynamically respond to sausage and hose instabilities.

  2. Testing program for burning plasma experiment vacuum vessel bolted joint

    International Nuclear Information System (INIS)

    Hsueh, P.K.; Khan, M.Z.; Swanson, J.; Feng, T.; Dinkevich, S.; Warren, J.

    1992-01-01

    As presently designed, the Burning Plasma Experiment vacuum vessel will be segmentally fabricated and assembled by bolted joints in the field. Due to geometry constraints, most of the bolted joints have significant eccentricity which causes the joint behavior to be sensitive to joint clamping forces. Experience indicates that as a result of this eccentricity, the joint will tend to open at the side closest to the applied load with the extent of the opening being dependent on the initial preload. In this paper analytical models coupled with a confirmatory testing program are developed to investigate and predict the non-linear behavior of the vacuum vessel bolted joint

  3. Rotor characteristics experiments with cooling pipe/fender bolt-groups, HTR-500

    International Nuclear Information System (INIS)

    Froening.

    1990-01-01

    For the design of composite liners for prestressed concrete pressure vessels of high temperature reactors, the force-displacement relationship of rotor elements is required. The rotor elements link the liner with the vessel concrete and transfer loads between liner and concrete. The liner is mainly stressed only at the sheet level due to concrete upsetting because of external load, including creeping due to prestress, internal pressure and temperature, shrinkage and temperature difference between liner and concrete. In the region of planned peripheral disturbances (penetrations, sheet/transfers, etc.), and at places with unintentional imperfections (dents, points of impact with slightly different sheet thicknesses), the liner sheet may be displaced against the concrete. Such displacements lead to a shear load on fender bolts and cooling pipes. The strains develop slowly. They can also be cyclical owing to internal pressure and temperature changes, the amplitudes being low, however. In addition, tensile stress may be applied to the fender bolt rotors by the driving effect of the shear-stressed cooling pipes, by the liner bending strain at the edges of dented fields, or by external loads. (orig.) [de

  4. Mechanics of Re-Torquing in Bolted Flange Connections

    Science.gov (United States)

    Gordon, Ali P.; Drilling Brian; Weichman, Kyle; Kammerer, Catherine; Baldwin, Frank

    2010-01-01

    It has been widely accepted that the phenomenon of time-dependent loosening of flange connections is a strong consequence of the viscous nature of the compression seal material. Characterizing the coupled interaction between gasket creep and elastic bolt stiffness has been useful in predicting conditions that facilitate leakage. Prior advances on this sub-class of bolted joints has lead to the development of (1) constitutive models for elastomerics, (2) initial tightening strategies, (3) etc. The effect of re-torque, which is a major consideration for typical bolted flange seals used on the Space Shuttle fleet, has not been fully characterized, however. The current study presents a systematic approach to characterizing bolted joint behavior as the consequence of sequentially applied torques. Based on exprimenta1 and numerical results, the optimal re-torquing parameters have been identified that allow for the negligible load loss after pre-load application

  5. Cost minimization of generation, storage, and new loads, comparing costs with and without externalities

    DEFF Research Database (Denmark)

    Noel, Lance Douglas; Brodie, Joseph; Kempton, Willett

    2017-01-01

    G) technology, and building heat) are modeled within the PJM Interconnection. The corresponding electric systems are then operated and constrained to meet the load every hour over four years. The total cost of each energy system is calculated, both with and without externalities, to find the least...... cost energy systems. Using today’s costs of conventional and renewable electricity and without adding any externalities, the cost-minimum system includes no renewable generation, but does include EVs. When externalities are included, however, the most cost-effective to system covers 50% of the electric...... load with renewable energy and runs reliably without need for either new conventional generation or purpose-built storage. The three novel energy policy implications of this research are: (1) using today’s cost of renewable electricity and estimates of externalities, it is cost effective to implement...

  6. Hydrodynamic interactions induce movement against an external load in a ratchet dimer Brownian motor.

    Science.gov (United States)

    Fornés, José A

    2010-01-15

    We use the Brownian dynamics with hydrodynamic interactions simulation in order to describe the movement of a elastically coupled dimer Brownian motor in a ratchet potential. The only external forces considered in our system were the load, the random thermal noise and an unbiased thermal fluctuation. For a given set of parameters we observe direct movement against the load force if hydrodynamic interactions were considered.

  7. Bolt Thread Stress Optimization

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2012-01-01

    of threads and therefore indirectly the bolt fatigue life. The root shape is circular, and from shape optimization for minimum stress concentration it is well known that the circular shape is seldom optimal. An axisymmetric Finite Element (FE) formulation is used to analyze the bolted connection, and a study...... is performed to establish the need for contact modeling with regard to finding the correct stress concentration factor. Optimization is performed with a simple parameterization with two design variables. Stress reduction of up to 9% is found in the optimization process, and some similarities are found...... in the optimized designs leading to the proposal of a new standard. The reductions in the stress are achieved by rather simple changes made to the cutting tool....

  8. Experimental results of superconducting magnet behaviour during discharging into the external load

    Directory of Open Access Journals (Sweden)

    Ladislav Grega

    2008-12-01

    Full Text Available The basic part of every SMES (Superconducting magnetic energy storage system is a superconducting magnet. All eventsof electrical nature which happen during its charging,, bypassing and discharging are transient. The article deals with experimentalresults of the superconducting magnet behaviour, especially during the period of its discharging into the prepared external load.

  9. The effect of elbow angle and external moment on load sharing of elbow muscles

    NARCIS (Netherlands)

    Praagman, M.; Chadwick, E.K.J.; van der Helm, F.C.T.; Veeger, H.E.J.

    2010-01-01

    To study elbow muscle load sharing we investigated the effect of external flexion-extension (FE) and pronation-supination (PS) moments and elbow angle on muscle activation and oxygen consumption (V̇O2).Two data sets were obtained. First, (n=6) electromyography (EMG) of elbow flexors (long and short

  10. 46 CFR 56.25-20 - Bolting.

    Science.gov (United States)

    2010-10-01

    ..., Blanks, Flange Facings, Gaskets, and Bolting § 56.25-20 Bolting. (a) General. (1) Bolts, studs, nuts, and....01-2). (2) Bolts and studs must extend completely through the nuts. (3) See § 58.30-15(c) of this... steel stud bolts must be threaded full length or, if desired, may have reduced shanks of a diameter not...

  11. 30 CFR 75.204 - Roof bolting.

    Science.gov (United States)

    2010-07-01

    ... accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the.... (4) In each roof bolting cycle, the actual torque or tension of the first tensioned roof bolt... during each roof bolting cycle shall be tested during or immediately after the first row of bolts has...

  12. Parametric study on the behaviour of bolted composite connections

    Directory of Open Access Journals (Sweden)

    M. N. Kataoka

    Full Text Available The studied connections are composed of concrete filled steel tubes (CFT connected to composite beams by passing through bolts, endplates and steel deck, which also contributes to support the applied loads. The parametric analysis presented in this work is based on numerical simulations performed with software TNO Diana, using experimental results to calibrate the reference numerical model. The influence of three main parameters, being them the bolts diameter, the slab height and the beams cross section, was evaluated. According to the obtained bending moment versus rotation curves, it was concluded that, among the three parameters analyzed, the most important one was the bolts diameter. About the beams cross section, inconclusive results were achieved, probably due to the incompatibility between the 16 mm bolts and the robust beam cross sections considered in the parametric analysis.

  13. Reinforcement of Underground Excavation with Expansion Shell Rock Bolt Equipped with Deformable Component

    Directory of Open Access Journals (Sweden)

    Korzeniowski Waldemar

    2017-03-01

    Full Text Available The basic type of rock mass reinforcement method for both preparatory and operational workings in underground metal ore mines, both in Poland and in different countries across the world, is the expansion shell or adhesive-bonded rock bolt. The article discusses results of static loading test of the expansion shell rock bolts equipped with originally developed deformable component. This component consists of two profiled rock bolt washers, two disk springs, and three guide bars. The disk spring and disk washer material differs in stiffness. The construction materials ensure that at first the springs under loading are partially compressed, and then the rock bolt washer is plastically deformed. The rock bolts tested were installed in blocks simulating a rock mass with rock compressive strength of 80 MPa. The rock bolt was loaded statically until its ultimate loading capacity was exceeded. The study presents the results obtained under laboratory conditions in the test rig allowing testing of the rock bolts at their natural size, as used in underground metal ore mines. The stress-strain/displacement characteristics of the expansion shell rock bolt with the deformable component were determined experimentally. The relationships between the geometric parameters and specific strains or displacements of the bolt rod were described, and the percentage contribution of those values in total displacements, resulting from the deformation of rock bolt support components (washer, thread and the expansion shell head displacements, were estimated. The stiffness of the yielded and stiff bolts was empirically determined, including stiffness parameters of every individual part (deformable component, steel rod. There were two phases of displacement observed during the static tension of the rock bolt which differed in their intensity.

  14. Experimental proof of a load resilient external matching solution for the ITER ICRH system

    International Nuclear Information System (INIS)

    Vervier, M.; Messiaen, A.; Dumortier, P.; Lamalle, P.

    2005-01-01

    A reliable load resilient external matching scheme for the ITER ICRH system has been successfully tested on the mock-up of the external matching system with variable plasma load simulation. To avoid the deleterious mutual coupling effects the power has been passively distributed among the upper half and the bottom half of the 24 radiating straps of the antenna plug. In this plug the straps are grouped in 8 triplets by 4-ports junctions. The 4 top and 4 bottom triplets are respectively put in parallel outside the antenna plug near a voltage anti-node by means of T junctions. The load resilient matching is then obtained by a 4 parameters single 'conjugate T' (CT) configuration. For an antenna loading variation of about 1 to 8 Ω/m the VSWR at the power source remains below 1.3. The maximum voltage along the line remains equal to the one in the antenna plug and there is a fair power share between the straps. A π0π0 toroidal phasing is easily obtained. The poloidal phasing between the top and bottom triplets is determined by the loading. A straightforward matching procedure is described. Good load resilience is also obtained by replacing the CT by one hybrid

  15. Critical current degradation in superconducting niobium-titanium alloys in external magnetic fields under loading

    International Nuclear Information System (INIS)

    Bojko, V.S.; Lazareva, M.B.; Starodubov, Ya.D.; Chernyj, O.V.; Gorbatenko, V.M.

    1992-01-01

    The effect of external magnetic fields on the stress at which the critical current starts to degrade (the degradation threshold σ 0 e ) under mechanical loads in superconducting Nb-Ti alloys is studied and a possible mechanism of realization of the effect observed is proposed.It is assumed that additional stresses on the transformation dislocation from the external magnetic fields are beneficial for the growth of martensite inclusions whose superconducting parameters (critical current density j k and critical temperature T k ) are lower then those in the initial material.The degradation threshold is studied experimentally in external magnetic fields H up to 7 T.The linear dependence σ 0 e (H) is observed.It is shown that external magnetic fields play an important role in the critical current degradation at the starting stages of deformation.This fact supports the assumption that the degradation of superconducting parameters under loading are due to the phenomenon of superelasticity,i.e. a reversible load-induced change in the martensite inclusions sizes rather than the reversible mechanical twinning.The results obtained are thought to be important to estimating superconducting solenoid stability in a wide range of magnetic fields

  16. Bond-Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading.

    Science.gov (United States)

    Li, Ke; Cao, Shuangyin; Yang, Yue; Zhu, Juntao

    2018-02-26

    The objective of this paper was to explore the bond-slip relationship between carbon fiber-reinforced polymer (CFRP) sheets and concrete under cyclic loading through experimental and analytical approaches. Modified beam tests were performed in order to gain insight into the bond-slip relationship under static and cyclic loading. The test variables are the CFRP-to-concrete width ratio, and the bond length of the CFRP sheets. An analysis of the test results in this paper and existing test results indicated that the slope of the ascending segment of the bond-slip curve decreased with an increase in the number of load cycles, but the slip corresponding to the maximum shear stress was almost invariable as the number of load cycles increased. In addition, the rate of reduction in the slope of the ascending range of the bond-slip curve during cyclic loading decreased as the concrete strength increased, and increased as the load level or CFRP-to-concrete width ratio enhanced. However, these were not affected by variations in bond length if the residual bond length was longer than the effective bond length. A bilinear bond-slip model for CFRP sheets that are externally bonded to concrete under cyclic loading, which considered the effects of the cyclic load level, concrete strength, and CFRP-to-concrete ratio, was developed based on the existing static bond-slip model. The accuracy of this proposed model was verified by a comparison between this proposed model and test results.

  17. Conditions of external loading of nuclear power plant structures by vapor cloud explosions and design requirements

    International Nuclear Information System (INIS)

    Geiger, W.

    1977-01-01

    In the design of nuclear power plant structures in the Federal Republic of Germany (FRG) the external loading by pressure waves from unconfined vapor cloud explosions is taken into account. The loading conditions used are based on simplified model considerations for the sequence of events which generates the pressure wave. The basic assumption is that the explosion of unconfined vapor clouds can evolve only in the form of a deflagration wave with a maximum overpressure of 0.3 bar. The research on gas explosions conducted in the FRG with a view to external reactor safety just as similar work in other countries demonstrates that there are still various problems which need further clarification. The principal issues are the maximum conceivable load and the modes of structrual response. This paper presents the main results of a status report commissioned by the German Ministry of the Inertior in which the whole sequence of events leading to the external loading of nuclear power plants and the corresponding response of the structure was scrutinized. Constitutive in establishing the status report have been thorough discussions with experts of the various fields. The following problem areas are discussed in the paper. Incidents leading to the release of large amounts of liquefied gas; Formation of explosive vapor clouds, ignition conditions; Development of the explosion, generation of the pressure wave; Interaction between pressure wave and reactor building. It is outlined where definite statements are possible and where uncertainties and information gaps exist. (Auth.)

  18. Relationships Between Internal and External Match-Load Indicators in Soccer Match Officials.

    Science.gov (United States)

    Castillo, Daniel; Weston, Matthew; McLaren, Shaun J; Cámara, Jesús; Yanci, Javier

    2017-08-01

    The aims of this study were to describe the internal and external match loads (ML) of refereeing activity during official soccer matches and to investigate the relationship among the methods of ML quantification across a competitive season. A further aim was to examine the usefulness of differential perceived exertion (dRPE) as a tool for monitoring internal ML in soccer referees. Twenty field referees (FRs) and 43 assistant referees (ARs) participated in the study. Data were collected from 30 competitive matches (FR = 20 observations, AR = 43 observations) and included measures of internal (Edwards' heart-rate-derived training impulse [TRIMP EDW ]) ML, external (total distance covered, distance covered at high speeds, and player load) ML, and ML differentiated ratings of perceived respiratory (sRPE res ) and leg-muscle (sRPE mus ) exertion. Internal and external ML were all greater for FRs than for ARs (-19.7 to -72.5), with differences ranging from very likely very large to most likely extremely large. The relationships between internal-ML and external-ML indicators were, in most cases, unclear for FR (r internal and external ML. Moreover, dRPE represents distinct dimensions of effort and may be useful in monitoring soccer referees' ML during official matches.

  19. Cost minimization of generation, storage, and new loads, comparing costs with and without externalities

    International Nuclear Information System (INIS)

    Noel, Lance; Brodie, Joseph F.; Kempton, Willett; Archer, Cristina L.; Budischak, Cory

    2017-01-01

    Highlights: • The study models a large regional transmission organization, with various amounts of renewable energy. • The cost of 86 million iterations of energy systems is calculated, with and without externalities. • When including externalities, society should implement 50% renewable energy. - Abstract: The goal of this research is to understand the economics of anticipated large-scale changes in the electric system. 86 million different combinations of renewable generation (wind and solar), natural gas, and three storage types (hydrogen storage, electric vehicles equipped with vehicle-to-grid (V2G) technology, and building heat) are modeled within the PJM Interconnection. The corresponding electric systems are then operated and constrained to meet the load every hour over four years. The total cost of each energy system is calculated, both with and without externalities, to find the least cost energy systems. Using today’s costs of conventional and renewable electricity and without adding any externalities, the cost-minimum system includes no renewable generation, but does include EVs. When externalities are included, however, the most cost-effective to system covers 50% of the electric load with renewable energy and runs reliably without need for either new conventional generation or purpose-built storage. The three novel energy policy implications of this research are: (1) using today’s cost of renewable electricity and estimates of externalities, it is cost effective to implement 240 GW of renewable electricity to meet 50% of the total electric load; (2) there is limited need to construct new natural gas power plants, especially from a system-wide perspective; and (3) existing coal plants may still be useful to the energy system, and instead of being retired, should be repurposed to occasionally provide generation.

  20. Hydraulic nuts (hydranuts) for critical bolted joints

    International Nuclear Information System (INIS)

    Greenwell, S.

    2008-01-01

    HydraNuts replace the original nut and torquing equipment, combining the two functions into one system. Designed for simple installation and operation, HydraNuts are fitted to the stud bolts. Once all HydraNuts are fitted to the application, flexible hydraulic hoses are connected, forming a closed loop hydraulic harness, allowing simultaneous pressurization of all HydraNuts. Hydraulic pressure is obtained by the use of a pumping unit and the resultant load generated is transferred to the studs and flange closure is obtained. Locking rings are rotated into place, supporting the tensioned load mechanically after hydraulic pressure is released. The hose harness is removed. (author)

  1. A Study on the Fracture Control of Rock Bolts in High Ground Pressure Roadways of Deep Mines

    Directory of Open Access Journals (Sweden)

    Wen Jinglin

    2015-01-01

    Full Text Available According to the frequent fractures of rock bolts in high ground pressure roadways of deep mines, this paper analyzes the mechanism of fractures and concludes that high ground pressure and material de-fects are main reasons for the fracture of rock bolts. The basic idea of fracture control of rock bolts in high ground pressure roadways of deep mines is to increase the yield load and the limit load of rock bolt materials and reduce the actual load of rock bolts. There are four ways of controlling rock bolt fracture: increasing the rock bolt diameter, strengthening bolt materials, weakening support rigidity and the implementation of double supporting. With the roadway support of the 2302 working face of a coal mine as the project background, this paper carries out a study on the effect of two schemes, increasing the rock bolt diameter and the double supporting technique through methods of theoretical analysis, numerical simulation and so on. It determines the most reasonable diam-eter of rock bolts and the best delay distance of secondary support. Practices indicate that rock bolt fracture can be effectively controlled through the double supporting technique, which strengthens the roof and two sides through the first supporting technique and strengthens side angles through the secondary supporting technique.

  2. Relationships Between the External and Internal Training Load in Professional Soccer: What Can We Learn From Machine Learning?

    Science.gov (United States)

    Jaspers, Arne; Beéck, Tim Op De; Brink, Michel S; Frencken, Wouter G P; Staes, Filip; Davis, Jesse J; Helsen, Werner F

    2017-12-28

    Machine learning may contribute to understanding the relationship between the external load and internal load in professional soccer. Therefore, the relationship between external load indicators and the rating of perceived exertion (RPE) was examined using machine learning techniques on a group and individual level. Training data were collected from 38 professional soccer players over two seasons. The external load was measured using global positioning system technology and accelerometry. The internal load was obtained using the RPE. Predictive models were constructed using two machine learning techniques, artificial neural networks (ANNs) and least absolute shrinkage and selection operator (LASSO), and one naive baseline method. The predictions were based on a large set of external load indicators. Using each technique, one group model involving all players and one individual model for each player was constructed. These models' performance on predicting the reported RPE values for future training sessions was compared to the naive baseline's performance. Both the ANN and LASSO models outperformed the baseline. Additionally, the LASSO model made more accurate predictions for the RPE than the ANN model. Furthermore, decelerations were identified as important external load indicators. Regardless of the applied machine learning technique, the group models resulted in equivalent or better predictions for the reported RPE values than the individual models. Machine learning techniques may have added value in predicting the RPE for future sessions to optimize training design and evaluation. Additionally, these techniques may be used in conjunction with expert knowledge to select key external load indicators for load monitoring.

  3. Development of a Unified Rock Bolt Model in Discontinuous Deformation Analysis

    Science.gov (United States)

    He, L.; An, X. M.; Zhao, X. B.; Zhao, Z. Y.; Zhao, J.

    2018-03-01

    In this paper, a unified rock bolt model is proposed and incorporated into the two-dimensional discontinuous deformation analysis. In the model, the bolt shank is discretized into a finite number of (modified) Euler-Bernoulli beam elements with the degrees of freedom represented at the end nodes, while the face plate is treated as solid blocks. The rock mass and the bolt shank deform independently, but interact with each other through a few anchored points. The interactions between the rock mass and the face plate are handled via general contact algorithm. Different types of rock bolts (e.g., Expansion Shell, fully grouted rebar, Split Set, cone bolt, Roofex, Garford and D-bolt) can be realized by specifying the corresponding constitutive model for the tangential behavior of the anchored points. Four failure modes, namely tensile failure and shear failure of the bolt shank, debonding along the bolt/rock interface and loss of the face plate, are available in the analysis procedure. The performance of a typical conventional rock bolt (fully grouted rebar) and a typical energy-absorbing rock bolt (D-bolt) under the scenarios of suspending loosened blocks and rock dilation is investigated using the proposed model. The reliability of the proposed model is verified by comparing the simulation results with theoretical predictions and experimental observations. The proposed model could be used to reveal the mechanism of each type of rock bolt in realistic scenarios and to provide a numerical way for presenting the detailed profile about the behavior of bolts, in particular at intermediate loading stages.

  4. Bolt study - behaviour of bolts in drop accident scenarios of the Nirex 3m3 Box ILW package

    International Nuclear Information System (INIS)

    Turner, G.; Tso, C.F.

    2004-01-01

    The mission of Nirex is to provide the UK with safe, environmentally sound and publicly acceptable options for the long-term management of radioactive materials. One of the key tasks is to ensure that waste is packaged by waste producers in a form which is suitable for safe storage, transport, handling and potential disposal. In pursuit of this key requirement, Nirex has developed specifications to set the standard for the design and performance of waste packages, and has developed standard containers for the packaging of intermediate level (ILW) and some low level waste (LLW) - one of these is the 3m 3 Box for immobilised operational and decommissioning ILW. The dimension envelope of this package is 1716 mm x 1716 mm in plan with 430 mm corner radii, 1226 mm tall. The maximum loaded weight is 12 tonnes. A generic design of this container has been developed, which is a welded structure manufactured from austenitic stainless steel (EN 10088-2 steel number 1.4404). The lid is connected to the body by 28 stainless steel bolts. An extensive study was carried out to develop a robust FE model of the bolts. The specific focus of this work was to use improved bolt modelling to optimize the design of the 3m 3 Box, although this work could be applied to other bolted containers. This paper presents a summary of the findings from the study as follows: 1. Development of a FE bolt model for application in a 3m 3 Box model. 2. Development and execution of a bolt testing programme which included tensile and shear tests on a total of 88 bolts, representing four grades of stainless steel materials, three thread sizes, and two geometries at three strain rates. 3. Benchmarking of the FE bolt model that can be used with confidence in simulating waste package behaviour in drop scenarios

  5. Bond–Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading

    Science.gov (United States)

    Li, Ke; Cao, Shuangyin; Yang, Yue; Zhu, Juntao

    2018-01-01

    The objective of this paper was to explore the bond–slip relationship between carbon fiber-reinforced polymer (CFRP) sheets and concrete under cyclic loading through experimental and analytical approaches. Modified beam tests were performed in order to gain insight into the bond–slip relationship under static and cyclic loading. The test variables are the CFRP-to-concrete width ratio, and the bond length of the CFRP sheets. An analysis of the test results in this paper and existing test results indicated that the slope of the ascending segment of the bond–slip curve decreased with an increase in the number of load cycles, but the slip corresponding to the maximum shear stress was almost invariable as the number of load cycles increased. In addition, the rate of reduction in the slope of the ascending range of the bond–slip curve during cyclic loading decreased as the concrete strength increased, and increased as the load level or CFRP-to-concrete width ratio enhanced. However, these were not affected by variations in bond length if the residual bond length was longer than the effective bond length. A bilinear bond–slip model for CFRP sheets that are externally bonded to concrete under cyclic loading, which considered the effects of the cyclic load level, concrete strength, and CFRP-to-concrete ratio, was developed based on the existing static bond–slip model. The accuracy of this proposed model was verified by a comparison between this proposed model and test results. PMID:29495383

  6. Fourier series analysis of a cylindrical pressure vessel subjected to axial end load and external pressure

    International Nuclear Information System (INIS)

    Brar, Gurinder Singh; Hari, Yogeshwar; Williams, Dennis K.

    2013-01-01

    This paper presents the comparison of a reliability technique that employs a Fourier series representation of random axisymmetric and asymmetric imperfections in a cylindrical pressure vessel subjected to an axial end load and external pressure, with evaluations prescribed by the ASME Boiler and Pressure Vessel Code, Section VIII, Division 2 Rules. The ultimate goal of the reliability technique described herein is to predict the critical buckling load associated with the subject cylindrical pressure vessel. Initial geometric imperfections are shown to have a significant effect on the calculated load carrying capacity of the vessel. Fourier decomposition was employed to interpret imperfections as structural features that can be easily related to various other types of defined imperfections. The initial functional description of the imperfections consists of an axisymmetric portion and a deviant portion, which are availed in the form of a double Fourier series. Fifty simulated shells generated by the Monte Carlo technique are employed in the final prediction of the critical buckling load. The representation of initial geometrical imperfections in the cylindrical pressure vessel requires the determination of respective Fourier coefficients. Multi-mode analyses are expanded to evaluate a large number of potential buckling modes for both predefined geometries in combination with asymmetric imperfections as a function of position within the given cylindrical shell. The probability of the ultimate buckling stress exceeding a predefined threshold stress is also calculated. The method and results described herein are in stark contrast to the “knockdown factor” approach as applied to compressive stress evaluations currently utilized in industry. Further effort is needed to improve on the current design rules regarding column buckling of large diameter pressure vessels subjected to an axial end load and external pressure designed in accordance with ASME Boiler and

  7. Thermomechanical behaviour of bolted assemblies

    International Nuclear Information System (INIS)

    Scliffet, L.

    1995-01-01

    This paper presents first results obtained in an R and D study on the thermomechanical behaviour of bolted assemblies. Thermal shocks during operating transients both severely distort such assemblies and cause variations in stud pre-loads. So during a hot shock, the thermal gradient in the flange induced over-tightening due to the differential thermal expansion involved. Over-tightening can reach 70% of the nominal value, usually after 10 to 15 mn, after which the stress relaxes as soon as the heating affects the stud. A series of hot shocks causes assembly fatigue, notably resulting in thread plasticization, making it impossible to tighten the studs. In the case of cold transients, the reverse phenomenon is observed. The hot flange contracts sharply upon contact with the cold fluid, causing stress relief in the expanded studs. The resulting loss of tensile stress, which reaches up to 50%, can then cause severe leakage, especially if the nominal tightening capacity is already impaired. The study presented is based on tests and modelling. (author). 16 figs

  8. Effects of external loads on postural sway during quiet stance in adults aged 20-80 years.

    Science.gov (United States)

    Hill, M W; Duncan, M J; Oxford, S W; Kay, A D; Price, M J

    2018-01-01

    The purpose of this study was to investigate the effects of holding external loads on postural sway during upright stance across age decades. Sixty-five healthy adults (females, n = 35), aged 18-80 years were assessed in four conditions; (1) standing without holding a load, holding a load corresponding to 5% body mass in the (2) left hand, (3) right hand and (4) both hands. The centre of pressure (COP) path length and anteroposterior and mediolateral COP displacement were used to indirectly assess postural sway. External loading elicited reductions in COP measures of postural sway in older age groups only (P  0.05). Holding external loads during standing is relevant to many activities of daily living (i.e. holding groceries). The reduction in postural sway may suggest this type of loading has a stabilising effect during quiet standing among older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A Synthetic Phased Array Surface Acoustic Wave Sensor for Quantifying Bolt Tension

    Directory of Open Access Journals (Sweden)

    Rasim Guldiken

    2012-09-01

    Full Text Available In this paper, we report our findings on implementing a synthetic phased array surface acoustic wave sensor to quantify bolt tension. Maintaining proper bolt tension is important in many fields such as for ensuring safe operation of civil infrastructures. Significant advantages of this relatively simple methodology is its capability to assess bolt tension without any contact with the bolt, thus enabling measurement at inaccessible locations, multiple bolt measurement capability at a time, not requiring data collection during the installation and no calibration requirements. We performed detailed experiments on a custom-built flexible bench-top experimental setup consisting of 1018 steel plate of 12.7 mm (½ in thickness, a 6.4 mm (¼ in grade 8 bolt and a stainless steel washer with 19 mm (¾ in of external diameter. Our results indicate that this method is not only capable of clearly distinguishing properly bolted joints from loosened joints but also capable of quantifying how loose the bolt actually is. We also conducted detailed signal-to-noise (SNR analysis and showed that the SNR value for the entire bolt tension range was sufficient for image reconstruction.

  10. The evaluation on clamping force of high strength bolts by length parameter

    International Nuclear Information System (INIS)

    Kim, Kang-Seok; Nah, Hwan-Seon; Lee, Hyeon-Ju; Lee, Kang-Min

    2009-01-01

    It has been reported that the length parameter of high strength bolts results in the variance in tension loads. The required turn for each length is specified in AISC RCSC specification. This study was focused on evaluating any influence on the clamping torque subjected to length parameter of high strength bolts. The two kinds of high strength bolts of specimen are as follows; High Strength Hexagon bolt defined on ASTM A490 and Torque Shear Bolt on KS B 2819. The length parameter ranged from 60mm(3d) to 140mm(7d). The torque, turn of nut and the clamping force were analyzed to review whether length parameter can be affected on the required tension load. To test whether the length parameter has an impact on the torque and turn of nut for the required strength and clamping force, statistical analysis is carried out. (author)

  11. Laboratory testing of a long expansion rock bolt support for energy-absorbing applications

    Directory of Open Access Journals (Sweden)

    Skrzypkowski Krzysztof

    2018-01-01

    Full Text Available The main purpose of rock support and reinforcement in underground mining is to maintain excavations safe and open for their intended lifespan. The basic type of rock mass reinforcement method both in ore and hard coal mining is rock bolt support. Very often, existing bolt support systems are not always capable of providing a reliable controlled performance. Therefore, in recent years energy-absorbing bolts which are exposed to dynamic loading, for example from rock burst caused by high rock stresses, earthquakes, or blasting have appeared. In this article particular attention was paid to short and long expansion bolts. Quasi-static tests of expansion bolts were carried out at the laboratory test facility in simulated mining conditions, especially for the KGHM Polska Miedź S.A. mines. In the underground mines of the Legnica-Głogów Copper District (LGOM the main way to protect the room excavation is rock bolt support with a length from 1.2 m to 2.6 m. Rock bolt support longer than 2.6 m is considered as additional support of excavations and is increasingly being used to reinforce the roofs. The comparisons of energy-absorbing short and long expansion bolts with a length of 1.8m, 3.6m and 5.2m were presented. In addition, for elastic and plastic range of each bolts were determined.

  12. Laboratory testing of a long expansion rock bolt support for energy-absorbing applications

    Science.gov (United States)

    Skrzypkowski, Krzysztof

    2018-01-01

    The main purpose of rock support and reinforcement in underground mining is to maintain excavations safe and open for their intended lifespan. The basic type of rock mass reinforcement method both in ore and hard coal mining is rock bolt support. Very often, existing bolt support systems are not always capable of providing a reliable controlled performance. Therefore, in recent years energy-absorbing bolts which are exposed to dynamic loading, for example from rock burst caused by high rock stresses, earthquakes, or blasting have appeared. In this article particular attention was paid to short and long expansion bolts. Quasi-static tests of expansion bolts were carried out at the laboratory test facility in simulated mining conditions, especially for the KGHM Polska Miedź S.A. mines. In the underground mines of the Legnica-Głogów Copper District (LGOM) the main way to protect the room excavation is rock bolt support with a length from 1.2 m to 2.6 m. Rock bolt support longer than 2.6 m is considered as additional support of excavations and is increasingly being used to reinforce the roofs. The comparisons of energy-absorbing short and long expansion bolts with a length of 1.8m, 3.6m and 5.2m were presented. In addition, for elastic and plastic range of each bolts were determined.

  13. Ultrasonic extensometer measures bolt preload

    Science.gov (United States)

    Daniels, C. M., Jr.

    1978-01-01

    Extensometer using ultrasonic pulse reflections to measure elongations in tightened belts and studs is much more accurate than conventional torque wrenches in application of specified preload to bolts and other threaded fasteners.

  14. Improvement of fatigue resistance for multilayer lead zirconate titanate (PZT)-based ceramic actuators by external mechanical loads

    Science.gov (United States)

    Yang, Gang; Yue, Zhenxing; Ji, Ye; Chu, Xiangcheng; Li, Longtu

    2008-12-01

    The influence of external compressive loads, applied along a direction perpendicular to polarization, on fatigue behaviors of multilayer lead zirconate titanate (PZT)-based ceramic actuators was investigated. Under no external mechanical load, a normal fatigue behavior was observed, demonstrating that both switching polarization (Pswitching) and remnant polarization (Pr) progressively decreased with increasing switching cycles due to domain pinning by charge point defects. However, an anomalous enhancement in both switching and remnant polarizations was observed upon application of the external compressive loads. After 5×106 cycles of polarization switching, Pswitching and Pr increase by about 13% and 6% at 40 MPa, respectively, while Pswitching and Pr increase by about 11% and 21% at 60 MPa, respectively. The improvement of fatigue resistance can be attributed to non-180° domain switching and suppression of microcracking, triggered by external mechanical loads.

  15. Factors related to external loads in buried pipelines; Consideracoes quanto as variaveis relacionadas ao carregamento externo em dutos enterrados

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Carlos E.C.; Silva, Breno S.; Fernandes, Lincoln F.; Santos Junior, Sergio J.F. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Louzada, Carlos H.C.M.

    2005-07-01

    Work of heavy equipment or vehicles above existent right-of-ways, may cause undesired external overload at buried pipelines in operation. The effect of these loads shall be analyzed considering the deflections and stresses on the pipelines. The major variables, nominal diameter, thickness, material, soil parameters, operation pressure and external loads shall be related and verified according to the limits from original project. Cases when the external loads cause higher efforts, the traffic over the pipelines shall be restricted in order to avoid damages. In other cases, it may be adapted to any technical alternatives to modify the parameters in such a way to make possible work above the right-of-way, such as increase the machine support area, increase backfill covering, a reduction in the internal operation pressure in a short time, etc. This work presents the study on the parameters used to establish the maximum allowable external loads over buried pipelines in operation. (author)

  16. External Load Affects Ground Reaction Force Parameters Non-uniformly during Running in Weightlessness

    Science.gov (United States)

    DeWitt, John; Schaffner, Grant; Laughlin, Mitzi; Loehr, James; Hagan, R. Donald

    2004-01-01

    Long-term exposure to microgravity induces detrimefits to the musculcskdetal system (Schneider et al., 1995; LeBlanc et al., 2000). Treadmill exercise is used onboard the International Space Station as an exercise countermeasure to musculoskeletal deconditioning due to spaceflight. During locomotive exercise in weightlessness (0G), crewmembers wear a harness attached to an external loading mechanism (EL). The EL pulls the crewmember toward the treadmill, and provides resistive load during the impact and propulsive phases of gait. The resulting forces may be important in stimulating bone maintenance (Turner, 1998). The EL can be applied via a bungee and carabineer clip configuration attached to the harness and can be manipulated to create varying amounts of load levels during exercise. Ground-based research performed using a vertically mounted treadmill found that peak ground reaction forces (GRF) during running at an EL of less than one body weight (BW) are less than those that occur during running in normal gravity (1G) (Davis et al., 1996). However, it is not known how the GRF are affected by the EL in a true OG environment. Locomotion while suspended may result in biomechanics that differ from free running. The purpose of this investigation was to determine how EL affects peak impact force, peak propulsive force, loading rate, and impulse of the GRF during running in 0G. It was hypothesized that increasing EL would result in increases in each GRF parameter.

  17. Nonlinear analysis of reinforced concrete structures subjected to high temperature and external load

    International Nuclear Information System (INIS)

    Sugawara, Y.; Goto, M.; Saito, K.; Suzuki, N.; Muto, A.; Ueda, M.

    1993-01-01

    A quarter of a century has passed since the finite element method was first applied to nonlinear problems concerning reinforced concrete structures, and the reliability of the analysis at ordinary temperature has been enhanced accordingly. By contrast, few studies have tried to deal with the nonlinear behavior of reinforced concrete structures subjected to high temperature and external loads simultaneously. It is generally known that the mechanical properties of concrete and steel are affected greatly by temperature. Therefore, in order to analyze the nonlinear behavior of reinforced concrete subjected to external loads at high temperature, it is necessary to construct constitutive models of the materials reflecting the influence of temperature. In this study, constitutive models of concrete and reinforcement that can express decreases in strength and stiffness at high temperature have been developed. A two-dimensional nonlinear finite element analysis program has been developed by use of these material models. The behavior of reinforced concrete beams subjected simultaneously to high temperature and shear forces were simulated using the developed analytical method. The results of the simulation agreed well with the experimental results, evidencing the validity of the developed material models and the finite element analysis program

  18. Transient behavior of high-interaction MHD generator following external loading faults

    International Nuclear Information System (INIS)

    Ishikawa, Motoo

    1983-01-01

    Transient behavior consequent to external loading faults is studied numerically on four configurations of high-interaction MHD generators-subsonic Faraday, supersonic Faraday, subsonic diagonal and supersonic diagonal, to provide a variable data base to serve in selecting the type of large-scale MHD generator. Time-dependent one-dimensional Navier-Stokes equations are solved with the 1969 MacCormack method, in combination with the Maxwell equations and the generalized Ohm's law. An artificial viscosity term is added to the Navier-Stokes equations to maintain numerical stability. It is shown that, with both supersonic and subsonic flows, the Faraday generator is liable to sustain more harmful effect from short than from open faults of the external loading circuit. For large-scale diagonal types, on the other hand, open faults are more dangerous. With subsonic flow, a shock wave propagating upstream is induced by short fault in the Faraday, and by open fault in the diagonal-type generator. In the case of supersonic flow, propagation upstream of the disturbance is completely obstructed. Larger electrical stress is foreseen for Faraday than for diagonal configuration. (author)

  19. A Component-Based Study of the Effect of Diameter on Bond and Anchorage Characteristics of Blind-Bolted Connections.

    Directory of Open Access Journals (Sweden)

    Muhammad Nasir Amin

    Full Text Available Structural hollow sections are gaining worldwide importance due to their structural and architectural advantages over open steel sections. The only obstacle to their use is their connection with other structural members. To overcome the obstacle of tightening the bolt from one side has given birth to the concept of blind bolts. Blind bolts, being the practical solution to the connection hindrance for the use of hollow and concrete filled hollow sections play a vital role. Flowdrill, the Huck High Strength Blind Bolt and the Lindapter Hollobolt are the well-known commercially available blind bolts. Although the development of blind bolts has largely resolved this issue, the use of structural hollow sections remains limited to shear resistance. Therefore, a new modified version of the blind bolt, known as the "Extended Hollo-Bolt" (EHB due to its enhanced capacity for bonding with concrete, can overcome the issue of low moment resistance capacity associated with blind-bolted connections. The load transfer mechanism of this recently developed blind bolt remains unclear, however. This study uses a parametric approach to characterising the EHB, using diameter as the variable parameter. Stiffness and load-carrying capacity were evaluated at two different bolt sizes. To investigate the load transfer mechanism, a component-based study of the bond and anchorage characteristics was performed by breaking down the EHB into its components. The results of the study provide insight into the load transfer mechanism of the blind bolt in question. The proposed component-based model was validated by a spring model, through which the stiffness of the EHB was compared to that of its components combined. The combined stiffness of the components was found to be roughly equivalent to that of the EHB as a whole, validating the use of this component-based approach.

  20. A Component-Based Study of the Effect of Diameter on Bond and Anchorage Characteristics of Blind-Bolted Connections.

    Science.gov (United States)

    Amin, Muhammad Nasir; Zaheer, Salman; Alazba, Abdulrahman Ali; Saleem, Muhammad Umair; Niazi, Muhammad Umar Khan; Khurram, Nauman; Amin, Muhammad Tahir

    2016-01-01

    Structural hollow sections are gaining worldwide importance due to their structural and architectural advantages over open steel sections. The only obstacle to their use is their connection with other structural members. To overcome the obstacle of tightening the bolt from one side has given birth to the concept of blind bolts. Blind bolts, being the practical solution to the connection hindrance for the use of hollow and concrete filled hollow sections play a vital role. Flowdrill, the Huck High Strength Blind Bolt and the Lindapter Hollobolt are the well-known commercially available blind bolts. Although the development of blind bolts has largely resolved this issue, the use of structural hollow sections remains limited to shear resistance. Therefore, a new modified version of the blind bolt, known as the "Extended Hollo-Bolt" (EHB) due to its enhanced capacity for bonding with concrete, can overcome the issue of low moment resistance capacity associated with blind-bolted connections. The load transfer mechanism of this recently developed blind bolt remains unclear, however. This study uses a parametric approach to characterising the EHB, using diameter as the variable parameter. Stiffness and load-carrying capacity were evaluated at two different bolt sizes. To investigate the load transfer mechanism, a component-based study of the bond and anchorage characteristics was performed by breaking down the EHB into its components. The results of the study provide insight into the load transfer mechanism of the blind bolt in question. The proposed component-based model was validated by a spring model, through which the stiffness of the EHB was compared to that of its components combined. The combined stiffness of the components was found to be roughly equivalent to that of the EHB as a whole, validating the use of this component-based approach.

  1. Experimental studies on the effects of bolt parameters on the bearing characteristics of reinforced rock.

    Science.gov (United States)

    Cheng, Liang; Zhang, Yidong; Ji, Ming; Zhang, Kai; Zhang, Minglei

    2016-01-01

    Roadways supported by bolts contain support structures that are built into the rock surrounding the roadway, referred to as reinforced rocks in this paper. Using physical model simulation, the paper investigates the bearing characteristics of the reinforced rock under different bolt parameters with incrementally increased load. The experimental results show that the stress at the measurement point inside the structure varies with the kinetic pressure. The stress increases slowly as the load is initially applied, displays accelerated growth in the middle of the loading application, and decreases or remains constant in the later stage of the loading application. The change in displacement of the surrounding rock exhibits the following characteristics: a slow increase when the load is first applied, accelerated growth in the middle stage, and violent growth in the later stage. There is a good correlation between the change in the measured stress and the change in the surrounding rock displacement. Increasing the density of the bolt support and the length and diameter of the bolt improves the load-bearing performance of the reinforced rock, including its strength, internal peak stress, and residual stress. Bolting improves the internal structure of the surrounding rocks, and the deterioration of the surrounding rock decreases with the distance between the bolt supports.

  2. Individualized Internal and External Training Load Relationships in Elite Wheelchair Rugby Players.

    Science.gov (United States)

    Paulson, Thomas A W; Mason, Barry; Rhodes, James; Goosey-Tolfrey, Victoria L

    2015-01-01

    The quantification and longitudinal monitoring of athlete training load (TL) provides a scientific explanation for changes in performance and helps manage injury/illness risk. Therefore, accurate and reliable monitoring tools are essential for the optimization of athletic performance. The aim of the present study was to establish the relationship between measures of internal [heart rate (HR) and session RPE (sRPE)] and external TL specific to wheelchair rugby (WR). Fourteen international WR athletes (age = 29 ± 7 years; body mass = 58.9 ± 10.9 kg) were monitored during 18 training sessions over a 3 month period during the competitive phase of the season. Activity profiles were collected during each training session using a radio-frequency based indoor tracking system (ITS). External TL was quantified by total distance (m) covered as well as time spent and distance covered in a range of classification-specific arbitrary speed zones. Banister's TRIMP, Edwards's summated HR zone (SHRZ), and Lucia's TRIMP methods were used to quantify physiological internal TL. sRPE was calculated as the product of session duration multiplied by perceived exertion using the Borg CR10 scale. Relationships between external and internal TL were examined using correlation coefficients and the 90% confidence intervals (90% CI). sRPE (r = 0.59) and all HR-based (r > 0.80) methods showed large and very large relationships with the total distance covered during training sessions, respectively. Large and very large correlations (r = 0.56 - 0.82) were also observed between all measures of internal TL and times spent and distances covered in low and moderate intensity speed zones. HR-based methods showed very large relationships with time (r = 0.71-0.75) and distance (r = 0.70-0.73) in the very high speed zone and a large relationship with the number of high intensity activities (HIA) performed (r = 0.56-0.62). Weaker relationships (r = 0.32-0.35) were observed between sRPE and all measures of

  3. Individualised internal and external training load relationships in elite wheelchair rugby players

    Directory of Open Access Journals (Sweden)

    Thomas Andrew William Paulson

    2015-12-01

    Full Text Available Aim: The quantification and longitudinal monitoring of athlete training load (TL provides a scientific explanation for changes in performance and helps manage injury/illness risk. The aim of the present study was to establish the relationship between measures of internal (heart rate (HR and session RPE (sRPE and external TL specific to wheelchair rugby (WR. Methods: Fourteen international WR athletes (age = 29 ± 7 yrs; body mass = 58.9 ± 10.9 kg were monitored during 18 training sessions over a 3 month period. Activity profiles were collected during each training session using a radio-frequency based indoor tracking system. External TL was quantified by total distance (m covered as well as time spent and distance covered in a range of classification-specific arbitrary speed zones. Banister’s TRIMP, Edwards’s summated HR zone (SHRZ and Lucia’s TRIMP methods were used to quantify physiological internal TL. sRPE was calculated as the product of session duration multiplied by perceived exertion using the Borg CR10 scale. Relationships between external and internal TL were examined using correlation coefficients and the 90% confidence intervals (90% CI. Results: sRPE (r=0.59 and all HR-based (r >0.80 methods showed large and very large relationships with the total distance covered during training sessions, respectively. Large and very large correlations (r =0.56-0.82 were also observed between all measures of internal TL and times spent and distances covered in low and moderate intensity speed zones. HR-based methods showed very large relationships with time (r=0.71-0.75 and distance (r=0.70-0.73 in the very high speed zone and a large relationship with the number of high intensity activities performed (r=0.56-0.62. Weaker relationships (r=0.32–0.35 were observed between sRPE and all measures of high intensity activity. A large variation of individual correlation co-efficient was observed between sRPE and all external TL measures

  4. Thermo-mechanical finite element analyses of bolted cask lid structures

    International Nuclear Information System (INIS)

    Wieser, G.; Qiao Linan; Eberle, A.; Voelzke, H.

    2004-01-01

    The analysis of complex bolted cask lid structures under mechanical or thermal accident conditions is important for the evaluation of cask integrity and leak-tightness in package design assessment according to the Transport Regulations or in aircraft crash scenarios. In this context BAM is developing methods based on Finite Elements to calculate the effects of mechanical impacts onto the bolted lid structures as well as effects caused by severe fire scenarios. I n case of fire it might be not enough to perform only a thermal heat transfer analysis. The complex cask design in connection with a severe hypothetical time-temperature-curve representing an accident fire scenario will create a strong transient heating up of the cask body and its lid system. This causes relative displacements between the seals and its counterparts that can be analyzed by a so-called thermo-mechanical calculation. Although it is currently not possible to correlate leakage rates with results from deformation analyses directly an appropriate Finite Element model of the considered type of metallic lid seal has been developed. For the present it is possible to estimate the behaviour of the seal based on the calculated relative displacements at its seating and the behaviour of the lid bolts under the impact load or the temperature field respectively. Except of the lid bolts the geometry of the cask and the mechanical loading is axial-symmetric which simplifies the analysis considerably and a two-dimensional Finite Element model with substitute lid bolts may be used. The substitute bolts are modelled as one-dimensional truss or beam elements. An advanced two-dimensional bolt submodel represents the bolts with plane stress continuum elements. This paper discusses the influence of different bolt modelling on the relative displacements at the seating of the seals. Besides this, the influence of bolt modelling, thermal properties and detail in geometry of the two-dimensional Finite Element models on

  5. Intelligent Control of Diesel Generators Using Gain-Scheduling Based on Online External-Load Estimation

    DEFF Research Database (Denmark)

    Mai, Christian; Jepsen, Kasper Lund; Yang, Zhenyu

    2014-01-01

    The development of an intelligent control solution for a wide range of diesel generators is discussed. Compared with most existing solutions, the advantages of the proposed solution lie in two folds: (i) The proposed control has the plug-and-play capability which is reflected by an automatic...... recognition procedure when it is plugged into a specific diesel generator, such that some extensive manual-tuning of the installed controller can be significantly reduced; (ii) The proposed control has an real-time adaptability by using the online external load estimation, such that the integrated system can...... keep a consistent performance for a wide range of operating conditions. Technically, a general nonlinear dynamic model is firstly developed based on fundamental principles of diesel generators. Then, the system parameters of this model can be identified experimentally or partially retrieved from...

  6. Stud bolt handling equipment for reactor vessel

    International Nuclear Information System (INIS)

    Bunyan, T.W.

    1989-01-01

    Reactor vessel stud bolt handling equipment includes means for transferring a stud bolt to a carrier from a parking station, or vice versa. Preferably a number of stud bolts are handled simultaneously. The transfer means may include cross arms rotatable about extendable columns, and the equipment is mounted on a mobile base for movement into and out of position. Each carrier comprises a tubular socket and an expandable sleeve to grip a stud bolt. (author)

  7. Quick-Connect, Slow-Disconnect Bolt

    Science.gov (United States)

    Weddendorf, Bruce

    1995-01-01

    Proposed bolt functions similarly to device described in article "Quick-Connect, Slow-Disconnect Nut" (MFS-28833). Bolt installed in standard threaded hole simply by pushing it into hole. Once inserted, bolt withdrawn only by turning it in conventional way.

  8. Effects of external pressure loading on human skin blood flow measured by 133Xe clearance

    International Nuclear Information System (INIS)

    Holloway, G.A. Jr.; Daly, C.H.; Kennedy, D.; Chimoskey, J.

    1976-01-01

    Forearm skin blood flow was measured during external pressure loading in normal human subjects using 133 Xe washout from intracutaneous injection sites. Pressures ranging between 5 and 150 mmHg were applied through a 3-cm-diameter disc placed over the site of flow determination. The pressure was maintained constant by a servo-controlled loading mechanism. Flow decreased with pressures from 5 to 10 and 30 to 150 mmHg, but remained constant with pressures from 10 to 30 mmHg. Reactive hyperemia occurred following removal of pressures of 90 mmHg or greater, but did not occur following removal of lower pressures. The pressure-flow curve for parasacral skin of paraplegic subjects closely paralleled the pressure-flow curve of normal skin at pressures tested: 5 to 15 mmHg. These data are interpreted to demonstrate autoregulation of skin blood flow. Autoregulation in parasacral skin of paraplegic subjects suggests a peripheral mechanism. The occurrence of hyperemia at pressures which exceed the ability of skin to autoregulate suggests that both autoregulation and post occlusion hyperemia may have the same mechanism

  9. The Integration of Internal and External Training Load Metrics in Hurling

    Directory of Open Access Journals (Sweden)

    Malone Shane

    2016-12-01

    Full Text Available The current study aimed to assess the relationship between the hurling player’s fitness profile and integrated training load (TL metrics. Twenty-five hurling players performed treadmill testing for VO2max, the speed at blood lactate concentrations of 2 mmol•L-1 (vLT and 4 mmol•L-1 (vOBLA and the heart rate-blood lactate profile for calculation of individual training impulse (iTRIMP. The total distance (TD; m, high speed distance (HSD; m and sprint distance (SD; m covered were measured using GPS technology (4-Hz, VX Sport, Lower Hutt, New Zealand which allowed for the measurement of the external TL. The external TL was divided by the internal TL to form integration ratios. Pearson correlation analyses allowed for the assessment of the relationships between fitness measures and the ratios to performance during simulated match play. External measures of the TL alone showed limited correlations with fitness measures. Integrated TL ratios showed significant relationships with fitness measures in players. TD:iTRIMP was correlated with aerobic fitness measures VO2max (r = 0.524; p = 0.006; 95% CI: 0.224 to 0.754; large and vOBLA (r = 0.559; p = 0.003; 95% CI: 0.254 to 0.854; large. HSD:iTRIMP also correlated with aerobic markers for fitness vLT (r = 0.502; p = 0.009; 95% CI: 0.204 to 0.801; large; vOBLA (r = 0.407; p = 0.039; 95% CI: 0.024 to 0.644; moderate. Interestingly SD:iTRIMP also showed significant correlations with vLT (r = 0.611; p = 0.001; 95% CI: 0.324 to 0.754; large. The current study showed that TL ratios can provide practitioners with a measure of fitness as external performance alone showed limited relationships with aerobic fitness measures.

  10. Neutron generation in lightning bolts

    International Nuclear Information System (INIS)

    Shah, G.N.; Razdan, H.; Bhat, C.L.; Ali, Q.M.

    1985-01-01

    To ascertain neutron generation in lightning bolts, the authors have searched for neutrons from individual lightning strokes, for a time-interval comparable with the duration of the lightning stroke. 10 7 -10 10 neutrons per stroke were found, thus providing the first experimental evidence that neutrons are generated in lightning discharges. (U.K.)

  11. Propagation of steady-state vibration in periodic pipes conveying fluid on elastic foundations with external moving loads

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Dianlong, E-mail: dianlongyu@yahoo.com.cn [Laboratory of Science and Technology on Integrated Logistics Support, National University of Defense Technology, Changsha 410073 (China); MOE Key Laboratory of Photonic and Phononic Crystals, National University of Defense Technology, Changsha 410073 (China); Wen, Jihong; Shen, Huijie; Wen, Xisen [Laboratory of Science and Technology on Integrated Logistics Support, National University of Defense Technology, Changsha 410073 (China); MOE Key Laboratory of Photonic and Phononic Crystals, National University of Defense Technology, Changsha 410073 (China)

    2012-10-01

    The propagation of steady-state vibration in a periodic pipe conveying fluid on elastic foundation with an external moving load is studied using wave propagation and attenuation theory. Wavenumbers and propagation properties in a moving coordinate system are investigated. The propagation constants are calculated using transfer matrix theory to determine whether the perturbation, which is introduced by an external moving load, can propagate through the pipe or not. The Bragg and locally resonant band gaps, corresponding to the velocity field, can exist in a periodic pipe system. In addition, the effects on both types of band gaps have been analysed.

  12. Propagation of steady-state vibration in periodic pipes conveying fluid on elastic foundations with external moving loads

    International Nuclear Information System (INIS)

    Yu, Dianlong; Wen, Jihong; Shen, Huijie; Wen, Xisen

    2012-01-01

    The propagation of steady-state vibration in a periodic pipe conveying fluid on elastic foundation with an external moving load is studied using wave propagation and attenuation theory. Wavenumbers and propagation properties in a moving coordinate system are investigated. The propagation constants are calculated using transfer matrix theory to determine whether the perturbation, which is introduced by an external moving load, can propagate through the pipe or not. The Bragg and locally resonant band gaps, corresponding to the velocity field, can exist in a periodic pipe system. In addition, the effects on both types of band gaps have been analysed.

  13. An approach for the design of closure bolts of spent fuel elements transportation packages

    International Nuclear Information System (INIS)

    Mattar Neto, Miguel; Miranda, Carlos A.J.; Fainer, Gerson

    2009-01-01

    The spent fuel elements transportation packages must be designed for severe conditions including significant fire and impact loads corresponding to hypothetical accident conditions. In general, these packages have large flat lids connected to cylindrical bodies by closure bolts that can be the weak link in the containment system. The bolted closure design depends on the geometrical characteristics of the flat lid and the cylindrical body, including their flanges, on the type of the gaskets and their dimensions, and on the number, strength, and tightness of the bolts. There are well established procedures for the closure bolts design used in pressure vessels and piping. They can not be used directly in the bolts design applied to transportation packages. Prior to the use of these procedures, it is necessary consider the differences in the main loads (pressure for the pressure vessels and piping and impact loads for the transportation packages) and in the geometry (large flat lids are not used in pressure vessels and piping). So, this paper presents an approach for the design of the closure bolts of spent fuel elements transportation packages considering the impact loads and the typical geometrical configuration of the transportation packages. (author)

  14. Effect of Court Dimensions on Players’ External and Internal Load during Small-Sided Handball Games

    Science.gov (United States)

    Corvino, Matteo; Tessitore, Antonio; Minganti, Carlo; Sibila, Marko

    2014-01-01

    The aim of this study was to investigate the effect of three different court dimensions on the internal and external load during small-sided handball games. Six male amateur handball players took part in this study and participated in three different 8-min 3vs3 (plus goalkeepers) small-sided handball games (each repeated twice). The three court dimensions were 12×24m, 30×15m and 32×16m. Through Global Positioning System devices (SPI pro elite 15Hz, GPSports) and video analysis, the following parameters were recorded: cyclic and acyclic movements (distance covered and number of technical actions executed), heart rate, and rating of perceived exertion (RPE). Total distance travelled increased with court dimensions (885.2m ± 66.6m in 24×12m; 980.0m ± 73.4m in 30×15m; 1095.0m ± 112.9m in 32×16m, p 5.2 m·s-1) highlighted substantial differences: playing with the 30×15m court in comparison to the 24×12m, the players covered less distance in the first speed zone (p = 0.012; ES = 0.70) and more distance in the second (p = 0.049; ES = 0.73) and third (p = 0.012; ES = 0.51) speed zones. Statistical differences were also found between the 24×12m and 32×16m courts: the players covered more distance in the second and third speed zones (p = 0.013, ES = 0.76; p = 0.023 ES = 0.69) with the 32×16m court in comparison to the 24×12m. There was no significant effect of court dimensions on the technical parameters (number of team actions, passes, piston movements toward goal and defensive activities), the number of specific handball jumps and changes of direction, and the time spent in the different heart rate zones. Considering the average data of all the experimental conditions together (24×12m, 30×15m, 32×16m), a pronounced statistical difference was highlighted between the values in first two HR zones and the last two (p handball games can be used to manipulate both external and internal loads on the players. Key points To cover the specific game demands, more

  15. Effect of Court Dimensions on Players' External and Internal Load during Small-Sided Handball Games.

    Science.gov (United States)

    Corvino, Matteo; Tessitore, Antonio; Minganti, Carlo; Sibila, Marko

    2014-05-01

    The aim of this study was to investigate the effect of three different court dimensions on the internal and external load during small-sided handball games. Six male amateur handball players took part in this study and participated in three different 8-min 3vs3 (plus goalkeepers) small-sided handball games (each repeated twice). The three court dimensions were 12×24m, 30×15m and 32×16m. Through Global Positioning System devices (SPI pro elite 15Hz, GPSports) and video analysis, the following parameters were recorded: cyclic and acyclic movements (distance covered and number of technical actions executed), heart rate, and rating of perceived exertion (RPE). Total distance travelled increased with court dimensions (885.2m ± 66.6m in 24×12m; 980.0m ± 73.4m in 30×15m; 1095.0m ± 112.9m in 32×16m, p 5.2 m·s(-1)) highlighted substantial differences: playing with the 30×15m court in comparison to the 24×12m, the players covered less distance in the first speed zone (p = 0.012; ES = 0.70) and more distance in the second (p = 0.049; ES = 0.73) and third (p = 0.012; ES = 0.51) speed zones. Statistical differences were also found between the 24×12m and 32×16m courts: the players covered more distance in the second and third speed zones (p = 0.013, ES = 0.76; p = 0.023 ES = 0.69) with the 32×16m court in comparison to the 24×12m. There was no significant effect of court dimensions on the technical parameters (number of team actions, passes, piston movements toward goal and defensive activities), the number of specific handball jumps and changes of direction, and the time spent in the different heart rate zones. Considering the average data of all the experimental conditions together (24×12m, 30×15m, 32×16m), a pronounced statistical difference was highlighted between the values in first two HR zones and the last two (p handball games can be used to manipulate both external and internal loads on the players. Key pointsTo cover the specific game demands, more

  16. Effect of Court Dimensions on Players’ External and Internal Load during Small-Sided Handball Games

    Directory of Open Access Journals (Sweden)

    Matteo Corvino

    2014-06-01

    Full Text Available The aim of this study was to investigate the effect of three different court dimensions on the internal and external load during small-sided handball games. Six male amateur handball players took part in this study and participated in three different 8-min 3vs3 (plus goalkeepers small-sided handball games (each repeated twice. The three court dimensions were 12×24m, 30×15m and 32×16m. Through Global Positioning System devices (SPI pro elite 15Hz, GPSports and video analysis, the following parameters were recorded: cyclic and acyclic movements (distance covered and number of technical actions executed, heart rate, and rating of perceived exertion (RPE. Total distance travelled increased with court dimensions (885.2m ± 66.6m in 24×12m; 980.0m ± 73.4m in 30×15m; 1095.0m ± 112.9m in 32×16m, p 5.2 m·s-1 highlighted substantial differences: playing with the 30×15m court in comparison to the 24×12m, the players covered less distance in the first speed zone (p = 0.012; ES = 0.70 and more distance in the second (p = 0.049; ES = 0.73 and third (p = 0.012; ES = 0.51 speed zones. Statistical differences were also found between the 24×12m and 32×16m courts: the players covered more distance in the second and third speed zones (p = 0.013, ES = 0.76; p = 0.023 ES = 0.69 with the 32×16m court in comparison to the 24×12m. There was no significant effect of court dimensions on the technical parameters (number of team actions, passes, piston movements toward goal and defensive activities, the number of specific handball jumps and changes of direction, and the time spent in the different heart rate zones. Considering the average data of all the experimental conditions together (24×12m, 30×15m, 32×16m, a pronounced statistical difference was highlighted between the values in first two HR zones and the last two (p < 0.05; large ES. The rating of perceived exertion was significantly higher during the drill with the 32×16m court compared with the 24

  17. Relationships Between Results Of An Internal And External Match Load Determining Method In Male, Singles Badminton Players.

    Science.gov (United States)

    Abdullahi, Yahaya; Coetzee, Ben; Van den Berg, Linda

    2017-07-03

    The study purpose was to determine relationships between results of internal and external match load determining methods. Twenty-one players, who participated in selected badminton championships during the 2014/2015 season served as subjects. The heart rate (HR) values and GPS data of each player were obtained via a fix Polar HR Transmitter Belt and MinimaxX GPS device. Moderate significant Spearman's rank correlations were found between HR and absolute duration (r = 0.43 at a low intensity (LI) and 0.44 at a high intensity (HI)), distance covered (r = 0.42 at a HI) and player load (PL) (r = 0.44 at a HI). Results also revealed an opposite trend for external and internal measures of load as the average relative HR value was found to be the highest for the HI zone (54.1%) compared to the relative measures of external load where average values (1.29-9.89%) were the lowest for the HI zone. In conclusion, our findings show that results of an internal and external badminton match load determining method are more related to each other in the HI zone than other zones and that the strength of relationships depend on the duration of activities that are performed in especially LI and HI zones. Overall, trivial to moderate relationships between results of an internal and external match load determining method in male, singles badminton players reaffirm the conclusions of others that these constructs measure distinctly different demands and should therefore be measured concurrently to fully understand the true requirements of badminton match play.

  18. Bifurcations and chaos of the nonlinear viscoelastic plates subjected to subsonic flow and external loads

    International Nuclear Information System (INIS)

    An, Fengxian; Chen, Fangqi

    2016-01-01

    Highlights: • The subharmonic bifurcations and chaotic motions are studied by means of Melnikov method. • The critical conditions for the occurrence of chaotic motions and subharmonic bifurcations are obtained. • The chaotic features on the system parameters are discussed. • The theoretical predictions are confirmed by numerical simulations. - Abstract: The subharmonic bifurcations and chaotic motions of the nonlinear viscoelastic plates subjected to subsonic flow and external loads are studied by means of Melnikov method. The critical conditions for the occurrence of chaotic motions are obtained. The chaotic features on the system parameters are discussed in detail. The conditions for subharmonic bifurcations are also obtained. For the system with no structural damping, chaotic motions can occur through infinite subharmonic bifurcations of odd orders. Furthermore, we confirm our theoretical predictions by numerical simulations. The theoretical results obtained here can help us to eliminate or suppress large nonlinear vibrations and chaotic motions of the nonlinear viscoelastic plates. Based on Melnikov method, complex dynamical behaviors of the nonlinear viscoelastic plates can be controlled by modifying the system parameters.

  19. The influence of variable range of motion training on neuromuscular performance and control of external loads.

    Science.gov (United States)

    Clark, Ross A; Humphries, Brendan; Hohmann, Erik; Bryant, Adam L

    2011-03-01

    Resistance training programs that emphasize high force production in different regions of the range of motion (ROM) may provide performance benefits. This study examined whether variable ROM (VROM) training, which consists of partial ROM training with countermovements performed in a different phase of the ROM for each set, results in improved functional performance. Twenty-two athletes (age 22.7 ± 2.4 years, height 1.81 ± 0.07 m, and body mass 94.6 ± 14.5 kg) with extensive resistance training backgrounds performed either a VROM or full ROM control (CON) 5-week, concentric work-matched training program. The participants were assigned to a group based on stratified randomization incorporating their strength levels and performance gains in preceding training microcycles. Testing consisted of assessing the force-ROM relationship during isokinetic and isometric bench press and ballistic bench throws, with normalized electromyography amplitude assessed during the isometric tests. Repeated-measure analyses of variance revealed that the VROM intervention significantly (p force (+15.7%), in addition to isokinetic peak force in the terminal ROM (13.5% increase). No significant differences were observed in the CON group or between groups for any other outcome measures. Analysis of the force-ROM relationship revealed that that the VROM intervention enhanced performance at shorter muscle lengths. These findings suggest that VROM training improves terminal and midrange performance gains, resulting in the athlete possessing an improved ability to control external loading and produce dynamic force.

  20. Design and implementation of an external quality assessment program for HIV viral load measurements using dried blood spots.

    Science.gov (United States)

    Prach, Lisa M; Puren, Adrian; Lippman, Sheri A; Carmona, Sergio; Stephenson, Sophie; Cutler, Ewalde; Barnhart, Scott; Liegler, Teri

    2015-03-01

    An external quality assurance program was developed for HIV-1 RNA viral load measurements taken from dried blood spots using a reference panel and field-collected specimens. The program demonstrated that accurate and reproducible quantitation can be obtained from field-collected specimens. Residual proviral DNA may confound interpretation in virologically suppressed subjects. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  1. Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

    Directory of Open Access Journals (Sweden)

    HamidReza Arab

    2015-09-01

    Full Text Available Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3i implant (3i Implant Innovation, Palm Beach Gardens, FL, USA. The evaluations were performed one year after loading. Materials and Methods: A total of 39 implants (23 external hex, 16 internal hex were placed randomly in 23 patients (10 male, 13 female by a submerged approach. None of patients had compromised conditions or parafunctional habits. At placement and at one year after loading, periapical radiographs were taken via the parallel method from the implant sites. Results: Crestal bone loss was -0.712±0.831 mm in implants with an internal hex connection and -0.139±0.505 mm in implants with an external hex connection (P≤0.05. No correlation was found between crestal bone loss and parameters such as age, gender, jaw, implant location (anterior, premolar, or molar, implant diameter, or implant length. Conclusions: Crestal bone loss was greater in patients with internal hex 3i implants than in those with external implants. Similar results in other clinical factors were found between the groups.

  2. The impact of cognitive control, incentives, and working memory load on the P3 responses of externalizing prisoners.

    Science.gov (United States)

    Baskin-Sommers, Arielle R; Krusemark, Elizabeth A; Curtin, John J; Lee, Christopher; Vujnovich, Aleice; Newman, Joseph P

    2014-02-01

    The P3 amplitude reduction is one of the most common correlates of externalizing. However, few studies have used experimental manipulations designed to challenge different cognitive functions in order to clarify the processes that impact this reduction. To examine factors moderating P3 amplitude in trait externalizing, we administered an n-back task that manipulated cognitive control demands, working memory load, and incentives to a sample of male offenders. Offenders with high trait externalizing scores did not display a global reduction in P3 amplitude. Rather, the negative association between trait externalizing and P3 amplitude was specific to trials involving inhibition of a dominant response during infrequent stimuli, in the context of low working memory load, and incentives for performance. In addition, we discuss the potential implications of these findings for externalizing-related psychopathologies. The results complement and expand previous work on the process-level dysfunction contributing to externalizing-related deficits in P3. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Conveyor system bolt failure analysis

    International Nuclear Information System (INIS)

    McCutcheon, S.H.; Waaser, R.E.

    1981-07-01

    The Savannah River Plant (SRP) is operated for the U.S. Department of Energy (DOE) by E.I. du Pont de Nemours and Co. Reactors at SRP are used to produce nuclear isotopes for national defense. As part of the routine operation of each of the reactors, irradiated fuel assemblies are remotely discharged from the reactor, transferred in air, and placed underwater in a Deposit and Exit (D and E) canal. The D and E conveyor transports the assemblies under the reactor room wall into the disassembly basin, where they are stored for several months before shipment to the separations areas. On August 13, 1980, a broken bolt was discovered on the D and E conveyor during a routine pre-operational inspection. The failed bolt was one of four which anchor a bearing on one of the conveyor drive shafts. All four of the bolts on the affected bearing were replaced as an immediate corrective measure and the discharge of irradiated fuel assemblies was subsequently completed without difficulty

  4. Anticorrosion protection of strength bolts

    Directory of Open Access Journals (Sweden)

    Jiří Votava

    2012-01-01

    Full Text Available Corrosion damage may, from the technical point of view, cause changes in mechanical and physical characteristics in particular, at the same time it may also cause changes in surface geometry. These aspects are likely to manifest themselves in all steel parts. The presented study looks at corrosion protection in bolts and bolt connections protected by metal coating based on zinc.Four different types of passivation, easily accessible on the Czech market, have been selected for this experiment. They are as follows: first, galvanic plating using white zinc; second, galvanic plating using yellow zinc; third, hot dip galvanizing; fourth, specific type of plating using the technology Dacromet 500 LC. In order to compare the given parameters there have been selected a unified M bolt size of 8 × 30 mm. The experimental part of this study can be further divided into two phases. The initial phase puts stress on the exact specification of the protection layer, namely, the analysis and establishment of the elemental compositon contained in the given coating, its microhardness, weight and thickness. The second phase of the experiment analyses the results of tests according to the norm ČSN ISO 9227 (Salt Fog Test and ČSN ISO 6988 (Sulphur Dioxide Test. With the tests we have concentrated on the initial stages of corrosion degradation and its overall process.

  5. Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants.

    Science.gov (United States)

    Mohammed, Hnd Hadi; Lee, Jin-Han; Bae, Ji-Myung; Cho, Hye-Won

    2016-02-01

    The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

  6. Thermo-mechanical analysis of PWR bolts susceptible to IASCC

    International Nuclear Information System (INIS)

    Matteoli, C.; Hannink, M.H.C.; Blom, F.J.; Marck, S.C. van der; Charpin-Jacobs, F.

    2015-01-01

    Irradiation Assisted Stress Corrosion Cracking (IASCC) is considered a primary ageing issue for the Reactor Pressure Vessel (RPV) internals of Pressurized Water Reactors (PWR). In particular, this complex phenomenon which develops in an environment featuring thermal and mechanical stresses, interaction with corrosive compounds and irradiation, is affecting the bolts connecting the baffles and the formers in the Nuclear Power Plants' RPVs. The baffle-former assembly is the structure that borders the fuel assemblies region, contributing to keep them in position and separating in the radial direction, the core region from the downcomer region. An evaluation of the stresses and temperatures reached in the baffle-former bolts during normal operation was performed by means of a coupled thermo-mechanical study which uses reactor physics calculations to obtain the fluence in the reactor core and as a consequence the heat deposition in the RPV internals. The heat deposition data are coupled with a finite element model of the bolts and the RPV internals in order to perform a complete analysis taking in account thermal, mechanical and radiation loadings. The study is first carried out focusing on a section of the RPV internals, showing a single row of baffle-former bolts. Then the work is extended to the full core height. The model set up in this work, includes an in-depth study of the behavior of the core internals, in particular baffle-former bolts. The model has the capability of understanding the mechanical and thermal behavior of essential internal components in a PWR. (authors)

  7. A Reduced Order Model of Force Displacement Curves for the Failure of Mechanical Bolts in Tension.

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Keegan J. [Univ. of Illinois, Urbana-Champaign, IL (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brake, Matthew Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry causes issues when generating a mesh of the model. This report will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. The results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.

  8. Restriction of Postoperative Joint Loading in a Murine Model of Anterior Cruciate Ligament Reconstruction: Botulinum Toxin Paralysis and External Fixation.

    Science.gov (United States)

    Lebaschi, Amir; Deng, Xiang-Hua; Coleman, Nathan W; Camp, Christopher L; Zong, Jianchun; Carbone, Andrew; Carballo, Camila B; Cong, Guang-Ting; Album, Zoe M; Rodeo, Scott A

    2017-09-01

    Control of knee motion in small animal models is necessary to study the effect of mechanical load on the healing process. This can be especially challenging in mice, which are being increasingly used for various orthopedic reconstruction models. We explored the feasibility of botulinum toxin (Botox; Allergan, Dublin, Ireland) paralysis and a newly designed external fixator to restrict motion of the knee in mice undergoing anterior cruciate ligament (ACL) reconstruction. Nineteen C57BL/6 mice were allocated to two groups: (1) Botox group ( n  = 9) and (2) external fixator group ( n  = 10). Mice in Botox group received two different doses of Botox: 0.25 unit ( n  = 3) and 0.5 unit ( n  = 6). Injection was performed 72 hours prior to ACL reconstruction into the quadriceps, hamstring, and calf muscles of the right hind leg. Mice in external fixator group received an external fixator following ACL reconstruction. Mice were monitored for survival, tolerance, and achievement of complete knee immobilization. All mice were meant for sacrifice on day 14 postoperatively. No perceptible change in gait was observed with 0.25 unit of Botox. All mice that received 0.5 unit of Botox had complete hind limb paralysis documented by footprint analysis 2 days after injection but failed to tolerate anesthesia and were euthanized 24 hours after operation due to their critical condition. In contrast, the external fixator was well tolerated and effectively immobilized the limb. There was a single occurrence of intraoperative technical error in the external fixator group that led to euthanasia. No mechanical failure or complication was observed. Botox paralysis was not a viable option for postoperative restriction of motion and joint loading in mice. However, external fixation was an effective method for complete knee immobilization and can be used in murine models requiring postoperative control of knee loading. This study introduces a robust research tool to allow control

  9. Forecasting of resonances vibration equipment with elastic waves coolant and with the external periodic loads on NPP with WWER

    International Nuclear Information System (INIS)

    Proskuryakov, K.N.; Zaporozhets, M.V.; Fedorov, A.I.

    2015-01-01

    Forecasting are carried out for external loads in relation to the main circulation circuit - dynamic loads caused by the rotation of the MCP, dynamic loads caused by the earthquake, dynamic loads caused by damage to the MCP in the earthquake. A comparison of the response spectrum of one of the variants of the base of the NPP, with the frequency vibration of the primary circuit equipment for NPP with WWER-1000 and self-frequency of elastic waves in the fluid. Analysis of the comparison results shows that the frequency of vibration of the main equipment of the reactor plant and elastic waves are in the frequency band in the spectrum response corresponding to the maximum amplitude of the seismic action [ru

  10. Elastic-Plastic Nonlinear Response of a Space Shuttle External Tank Stringer. Part 2; Thermal and Mechanical Loadings

    Science.gov (United States)

    Knight, Norman F., Jr.; Warren, Jerry E.; Elliott, Kenny B.; Song, Kyongchan; Raju, Ivatury S.

    2012-01-01

    Elastic-plastic, large-deflection nonlinear thermo-mechanical stress analyses are performed for the Space Shuttle external tank s intertank stringers. Detailed threedimensional finite element models are developed and used to investigate the stringer s elastic-plastic response for different thermal and mechanical loading events from assembly through flight. Assembly strains caused by initial installation on an intertank panel are accounted for in the analyses. Thermal loading due to tanking was determined to be the bounding loading event. The cryogenic shrinkage caused by tanking resulted in a rotation of the intertank chord flange towards the center of the intertank, which in turn loaded the intertank stringer feet. The analyses suggest that the strain levels near the first three fasteners remain sufficiently high that a failure may occur. The analyses also confirmed that the installation of radius blocks on the stringer feet ends results in an increase in the stringer capability.

  11. Professional users handbook for rock bolting

    Energy Technology Data Exchange (ETDEWEB)

    Stillborg, B.

    1986-01-01

    The paper is a practical handbook which reviews the basic principles of rock bolting and sets out the design considerations used for most types of rockbolts in current use. It discusses the characteristics of these bolts and gives information on installation procedures and the observations and measurement of rockbolt performance. Rockbolting is considered under the following chapter headings: review of typical rockbolt systems; rockbolt installation; testing of rockbolts; design considerations; design of rock reinforcement; monitoring; cost of rock bolting; and Atlas Lopco auxillary equipment for rock bolting. 45 refs.

  12. The Relationships Between Internal and External Measures of Training Load and Intensity in Team Sports: A Meta-Analysis.

    Science.gov (United States)

    McLaren, Shaun J; Macpherson, Tom W; Coutts, Aaron J; Hurst, Christopher; Spears, Iain R; Weston, Matthew

    2018-03-01

    The associations between internal and external measures of training load and intensity are important in understanding the training process and the validity of specific internal measures. We aimed to provide meta-analytic estimates of the relationships, as determined by a correlation coefficient, between internal and external measures of load and intensity during team-sport training and competition. A further aim was to examine the moderating effects of training mode on these relationships. We searched six electronic databases (Scopus, Web of Science, PubMed, MEDLINE, SPORTDiscus, CINAHL) for original research articles published up to September 2017. A Boolean search phrase was created to include search terms relevant to team-sport athletes (population; 37 keywords), internal load (dependent variable; 35 keywords), and external load (independent variable; 81 keywords). Articles were considered for meta-analysis when a correlation coefficient describing the association between at least one internal and one external measure of session load or intensity, measured in the time or frequency domain, was obtained from team-sport athletes during normal training or match-play (i.e., unstructured observational study). The final data sample included 122 estimates from 13 independent studies describing 15 unique relationships between three internal and nine external measures of load and intensity. This sample included 295 athletes and 10,418 individual session observations. Internal measures were session ratings of perceived exertion (sRPE), sRPE training load (sRPE-TL), and heart-rate-derived training impulse (TRIMP). External measures were total distance (TD), the distance covered at high and very high speeds (HSRD ≥ 13.1-15.0 km h -1 and VHSRD ≥ 16.9-19.8 km h -1 , respectively), accelerometer load (AL), and the number of sustained impacts (Impacts > 2-5 G). Distinct training modes were identified as either mixed (reference condition), skills, metabolic, or

  13. Evaluation of Interlaminar Stresses in Composite Laminates with a Bolt-Filled Hole Using a Linear Elastic Traction-Separation Description

    Directory of Open Access Journals (Sweden)

    Yong Cao

    2017-01-01

    Full Text Available Determination of the local interlaminar stress distribution in a laminate with a bolt-filled hole is helpful for optimal bolted joint design, due to the three-dimensional (3D nature of the stress field near the bolt hole. A new interlaminar stress distribution phenomenon induced by the bolt-head and clamp-up load, which occurs in a filled-hole composite laminate, is investigated. In order to efficiently evaluate interlaminar stresses under the complex boundary condition, a calculation strategy that using zero-thickness cohesive interface element is presented and validated. The interface element is based on a linear elastic traction-separation description. It is found that the interlaminar stress concentrations occur at the hole edge, as well as the interior of the laminate near the periphery of the bolt head. In addition, the interlaminar stresses near the periphery of the bolt head increased with an increase in the clamp-up load, and the interlaminar normal and shear stresses are not at the same circular position. Therefore, the clamp-up load cannot improve the interlaminar stress distribution in the laminate near the periphery of the bolt head, although it can reduce the magnitude of the interlaminar shear stress at the hole edge. Thus, the interlaminar stress distribution phenomena may lead to delamination initiation in the laminate near the periphery of the bolt head, and should be considered in composite bolted joint design.

  14. Protection against external impacts and missiles - Load assumption and effects on the plant design of a 1300 MW PWR-Plant

    International Nuclear Information System (INIS)

    Gremm, O.; Orth, K.H.

    1978-01-01

    The load assumptions and effects of the external impacts are given. The fundamental properties of the KWU standard design according to these impacts and the consequences for the engineering safeguards are explained. The protection against external impacts includes the protection against all external missiles. The basic measure of protection against internal missiles is the strict separation of redundancies. (author)

  15. External load application in gait and posture reeducation after diffuse axonal injury of the corpus callosum. A case report

    Directory of Open Access Journals (Sweden)

    Magdalena Zawadka

    2018-06-01

    Full Text Available Traumatic brain injury caused car accidents is the one of the most common causes of diffuse axonal injury typically located at the grey-white matter junction, in the corpus callosum. A 58-year-old female patient Caucasian race was admitted to the Orthopedic and Rehabilitation Unit with head injury, broken right ulnar bone, numerous broken ribs and broken right iliac crest. Neurological examination resulted in right-sided hemiparesis. There were also coordination and balance disorders while sitting and standing. The patient was unable to walk. After physiotherapy treatment included external load application (ankle weights and rucksack with weights in gait and posture reeducation, patient has improved balance, locomotion and body posture. However, application of external loads during walk and posture reeducation needs to be further investigated with greater number of participants and control group.

  16. Internal cycling, not external loading, decides the nutrient limitation in eutrophic lake: A dynamic model with temporal Bayesian hierarchical inference.

    Science.gov (United States)

    Wu, Zhen; Liu, Yong; Liang, Zhongyao; Wu, Sifeng; Guo, Huaicheng

    2017-06-01

    Lake eutrophication is associated with excessive anthropogenic nutrients (mainly nitrogen (N) and phosphorus (P)) and unobserved internal nutrient cycling. Despite the advances in understanding the role of external loadings, the contribution of internal nutrient cycling is still an open question. A dynamic mass-balance model was developed to simulate and measure the contributions of internal cycling and external loading. It was based on the temporal Bayesian Hierarchical Framework (BHM), where we explored the seasonal patterns in the dynamics of nutrient cycling processes and the limitation of N and P on phytoplankton growth in hyper-eutrophic Lake Dianchi, China. The dynamic patterns of the five state variables (Chla, TP, ammonia, nitrate and organic N) were simulated based on the model. Five parameters (algae growth rate, sediment exchange rate of N and P, nitrification rate and denitrification rate) were estimated based on BHM. The model provided a good fit to observations. Our model results highlighted the role of internal cycling of N and P in Lake Dianchi. The internal cycling processes contributed more than external loading to the N and P changes in the water column. Further insights into the nutrient limitation analysis indicated that the sediment exchange of P determined the P limitation. Allowing for the contribution of denitrification to N removal, N was the more limiting nutrient in most of the time, however, P was the more important nutrient for eutrophication management. For Lake Dianchi, it would not be possible to recover solely by reducing the external watershed nutrient load; the mechanisms of internal cycling should also be considered as an approach to inhibit the release of sediments and to enhance denitrification. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Fatigue behavior of a bolted assembly - a comparison between numerical analysis and experimental analysis

    International Nuclear Information System (INIS)

    Bosser, M.; Vagner, J.

    1987-01-01

    The fatigue behavior of a bolted assembly can be analysed, either by fatigue tests, or by computing the stress variations and using a fatigue curve. This paper presents the fatigue analysis of a stud-bolt and stud-flange of a steam generator manway carried out with the two methods. The experimental analysis is performed for various levels of load, according to the recommandations of the ASME code section III appendix II. The numerical analysis of the stresses is based on the results of a finite element analysis performed with the program SYSTUS. The maximum stresses are obtained in the first bolt threads. In using these stresses, the allowable number of cycles for each level of loading analysed, is obtained from fatigue curves, as defined in appendix I section III of the ASME code. The analysis underlines that, for each level of load the purely numerical approach is highly conservative, compared to the experimental approach. (orig.)

  18. Health Monitoring of Bolted Spherical Joint Connection Based on Active Sensing Technique Using Piezoceramic Transducers

    Directory of Open Access Journals (Sweden)

    Jing Xu

    2018-05-01

    Full Text Available Bolted spherical joints are widely used to form space steel structures. The stiffness and load capacity of the structures are affected by the looseness of bolted spherical joint connections in the structures. The looseness of the connections, which can be caused by fabrication error, low modeling accuracy, and “false twist” in the installation process, may negatively impact the load capacity of the structure and even lead to severe accidents. Furthermore, it is difficult to detect bolted spherical joint connection looseness from the outside since the bolts connect spheres with rods together from the inside. Active sensing methods are proposed in this paper to monitor the tightness status of the bolted spherical connection using piezoceramic transducers. A triangle-on-triangle offset grid composed of bolted spherical joints and steel tube bars was fabricated as the specimen and was used to validate the active sensing methods. Lead Zirconate Titanate (PZT patches were used as sensors and actuators to monitor the bolted spherical joint tightness status. One PZT patch mounted on the central bolted sphere at the upper chord was used as an actuator to generate a stress wave. Another PZT patch mounted on the bar was used as a sensor to detect the propagated waves through the bolted spherical connection. The looseness of the connection can impact the energy of the stress wave propagated through the connection. The wavelet packet analysis and time reversal (TR method were used to quantify the energy of the transmitted signal between the PZT patches by which the tightness status of the connection can be detected. In order to verify the effectiveness, repeatability, and consistency of the proposed methods, the experiments were repeated six times in different bolted spherical connection positions. The experimental results showed that the wavelet packet analysis and TR method are effective in detecting the tightness status of the connections. The

  19. Bolt-loosening identification of bolt connections by vision image-based technique

    Science.gov (United States)

    Nguyen, Tuan-Cuong; Huynh, Thanh-Canh; Ryu, Joo-Young; Park, Jae-Hyung; Kim, Jeong-Tae

    2016-04-01

    In this study, an algorithm using image processing techniques is proposed to identify bolt-loosening in bolted connections of steel structures. Its basic concept is to identify rotation angles of nuts from a pictured image, and is mainly consisted of the following 3 steps: (1) taking a picture for a bolt joint, (2) segmenting the images for each nut by image processing techniques, and (3) identifying rotation angle of each nut and detecting bolt-loosening. By using the concept, an algorithm is designed for continuous monitoring and inspection of the bolt connections. As a key imageprocessing technique, Hough transform is used to identify rotation angles of nuts, and then bolt-loosening is detected by comparing the angles before and after bolt-loosening. Then the applicability of the proposed algorithm is evaluated by experimental tests for two lab-scaled models. A bolted joint model which consists of a splice plate and 8 sets of bolts and nuts with 2×4 array is used to simulate inspection of bridge connections, and a model which is consisted of a ring flange and 32 sets of bolt and nut is used to simulate continuous monitoring of bolted connections in wind turbine towers.

  20. 5/8'' baffle bolt replacement

    International Nuclear Information System (INIS)

    Pinaud, T.; Grypczynski, D.

    1999-01-01

    Both Framatome Nuclear Services in France and its U.S. arm, FT1, are now equipped with baffle bolt inspection and replacement packages. These packages allow them to tackle baffle bold degradation on both two- and three-loop nuclear power plants. Framatome and FT1 together are world leaders in addressing reactor vessel internal bolting concerns

  1. Comparison of External Load Effect on Lumbar Lordosis Among between Low Back Pain Patients and Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Neda Ershad

    2007-10-01

    Full Text Available Objective: Lumbar curvature is an important factor in posture and body movement that help us to understand low back pain problems. The aim of this study was evaluation of external load and trunk posture effect on lumbar curvature under static condition.  Materials & Methods: This study is an interventional, quasi-experimental and case-control study. Ten women with non specific chronic low back pain and ten matched without low back pain women were participated in this study. We used simple and non random method for sampling. Two clinometers sensors were used to evaluate lumbar curvature. Six static tasks while holding three levels of load (0, 6, 12 Kg and two levels of trunk position (neutral and 30 degree of flexion were simulated for subjects. Data were analyzed by using Kolmogroff-Smirnoff, ANOVA (Repeated Measurement and independent T-test. Results: Findings revealed lumbar lordosis in patients with low back pain does not change to kyphosis while increasing external load from 0kg to 6kg and 12kg in neutral trunk position (P<0.05. Conclusion: Dysfunction in passive system due to soft tissue disorder, afraid of pain, changes trunk muscles recruitment and reduction of moment arm are likely reasons for increased lumbar lordosis in patients with low back pain during loading.

  2. The effect of external dynamic loads on the lifetime of rolling element bearings: accurate measurement of the bearing behaviour

    International Nuclear Information System (INIS)

    Jacobs, W; Boonen, R; Sas, P; Moens, D

    2012-01-01

    Accurate prediction of the lifetime of rolling element bearings is a crucial step towards a reliable design of many rotating machines. Recent research emphasizes an important influence of external dynamic loads on the lifetime of bearings. However, most lifetime calculations of bearings are based on the classical ISO 281 standard, neglecting this influence. For bearings subjected to highly varying loads, this leads to inaccurate estimations of the lifetime, and therefore excessive safety factors during the design and unexpected failures during operation. This paper presents a novel test rig, developed to analyse the behaviour of rolling element bearings subjected to highly varying loads. Since bearings are very precise machine components, their motion can only be measured in an accurately controlled environment. Otherwise, noise from other components and external influences such as temperature variations will dominate the measurements. The test rig is optimised to perform accurate measurements of the bearing behaviour. Also, the test bearing is fitted in a modular structure, which guarantees precise mounting and allows testing different types and sizes of bearings. Finally, a fully controlled multi-axial static and dynamic load is imposed on the bearing, while its behaviour is monitored with capacitive proximity probes.

  3. Integrity of Bolted Angle Connections Subjected to Simulated Column Removal

    Science.gov (United States)

    Weigand, Jonathan M.; Berman, Jeffrey W.

    2016-01-01

    Large-scale tests of steel gravity framing systems (SGFSs) have shown that the connections are critical to the system integrity, when a column suffers damage that compromises its ability to carry gravity loads. When supporting columns were removed, the SGFSs redistributed gravity loads through the development of an alternate load path in a sustained tensile configuration resulting from large vertical deflections. The ability of the system to sustain such an alternate load path depends on the capacity of the gravity connections to remain intact after undergoing large rotation and axial extension demands, for which they were not designed. This study experimentally evaluates the performance of steel bolted angle connections subjected to loading consistent with an interior column removal. The characteristic connection behaviors are described and the performance of multiple connection configurations are compared in terms of their peak resistances and deformation capacities. PMID:27110059

  4. Automation of strata bolting in iron mines

    Energy Technology Data Exchange (ETDEWEB)

    Belin, M; Lethuaire, M

    1978-01-01

    The Moyeure iron mine (Lorraine), with an output of 16,000 t/day, works 2 seams separated by a dirt band 6.50 m thick. The tyre-mounted Diesel Secoma jumbo for bolting operations can insert resin-embedded bolts 1.70 m in length. The jumbo is fitted with a standard universal boom with two settings - one for drilling and one for bolting. As the operator has to work in the unbolted zone in order to offer up the bolt on the boom and insert the resin cartridge, the mine in conjunction with the manufacturers, Secoma, have improved the safety and performance of the machine by adding three special attachments to the standard boom: a reamer, a resin-injection system and a bolt supply-magazine. Gives details of the results achieved. (In French)

  5. Device for measuring hole elongation in a bolted joint

    Science.gov (United States)

    Wichorek, Gregory R. (Inventor)

    1987-01-01

    A device to determine the operable failure mode of mechanically fastened lightweight composite joints by measuring the hole elongation of a bolted joint is disclosed. The double-lap joint test apparatus comprises a stud, a test specimen having a hole, two load transfer plates, and linear displacement measuring instruments. The test specimen is sandwiched between the two load transfer plates and clamped together with the stud. Spacer washers are placed between the test specimen and each load transfer plate to provide a known, controllable area for the determination of clamping forces around the hole of the specimen attributable to bolt torque. The spacer washers also provide a gap for the mounting of reference angles on each side of the test specimen. Under tensile loading, elongation of the hole of the test specimen causes the stud to move away from the reference angles. This displacement is measured by the voltage output of two linear displacement measuring instruments that are attached to the stud and remain in contact with the reference angles throughout the tensile loading. The present invention obviates previous problems in obtaining specimen deformation measurements by monitoring the reference angles to the test specimen and the linear displacement measuring instruments to the stud.

  6. Usage of prestressed vertical bolts for retrofitting flat slabs damaged due to punching shear

    Directory of Open Access Journals (Sweden)

    Hamed S. Askar

    2015-09-01

    An experimental investigation with the objective of retrofitting flat slabs damaged due to punching shear using prestressed vertical bolts is presented in this paper. The parameters examined in this study are vertical prestressed bolts with different ratios within the slab thickness, slab thickness and central column size. Through the experimental tests the load carrying capacity, deformation characteristics and the cracking behavior have been investigated. A comparison between the behavior of retrofitted slabs and their references showed that the proposed system of repair is effective and could be used in practice. A comparison between the experimental results and calculated punching failure load based on the formulas adopted by different codes, showed a reasonable agreement.

  7. Failure analysis of bolted joints in foam-core sandwich composites

    DEFF Research Database (Denmark)

    Zabihpoor, M.; Moslemian, Ramin; Afshin, M.

    2008-01-01

    This study represents an effort to predict the bearing strength, failure modes, and failure load of bolted joints in foam-core sandwich composites. The studied joints have been used in a light full composite airplane. By using solid laminates, a new design for the joint zone is developed. These s......This study represents an effort to predict the bearing strength, failure modes, and failure load of bolted joints in foam-core sandwich composites. The studied joints have been used in a light full composite airplane. By using solid laminates, a new design for the joint zone is developed...

  8. The Experimental Study of the Temperature Effect on the Interfacial Properties of Fully Grouted Rock Bolt

    Directory of Open Access Journals (Sweden)

    Fuhai Li

    2017-03-01

    Full Text Available This study analyzes the phenomenon of performance deterioration in fully grouted rock bolts in tunnels with a dry, hot environment and high geothermal activity with a focus on temperature effects on interfacial bond performance. Three groups of fully grouted rock bolt specimens were designed based on similar mechanical principles. They were produced and maintained at 20 °C, 35 °C, and 50 °C. Through the indoor gradual loading tensile test of specimens, variations of axial force and shear stress between the rock bolt and mortar adhesive interface were obtained under different environmental temperatures. Distribution of the axial force and shear stress on the anchorage section were found under different tensile forces. Results showed that, with an increase in specimen environmental temperature, maximum shear stress of the rock bolt section became smaller, while shear stress distribution along the rock bolt segment became more uniform. In addition, the axial force value at the same position along the pull end was greater, while axial stress along the anchorage’s length decayed faster. With an increase in tensile force under different temperatures, the axial force and maximum shear stress of rock bolt specimens along the anchorage section has a corresponding increase.

  9. X-ray measurement of residual stress on bolt threads

    International Nuclear Information System (INIS)

    Hagiwara, Masaya; Nakahara, Kanefumi; Yoshimoto, Isamu.

    1989-01-01

    This study deals with X-ray measurement of residual stress at the local area around the thread root of a bolt. Residual stress in the 0.5 mm x 5 mm area was measured using a method of stepped scanning and parabolic approximation. The conditions of measurement had been determined and evaluated through the preliminary measurement of compressive stress acting on the cylindrical surface. Furthermore, the fatigue strength estimated by applying the residual stress data to the previously presented hypothesis was compared with the experimental results. The main conclusions obtained were as follows: (1) The residual stress in a relatively small area on the cylindrical surface with large curvature can be measured by X-ray using a method of stepped scanning and parabolic approximation; (2) The compressive residual stress measured at the thread root was larger for the bolt manufactured by thread rolling after heat treatment than for one manufactured by thread rolling before heat treatment; (3) The distribution of residual stress along the axial direction from the thread root to the portion under crest did not represent remarkable change in its value; (4) The residual stress of a bolt was somewhat decreased by fatigue loading on the condition of low mean stress; (5) The fatigue strength estimated using residual stress data showed the tendency of experimental results well. (author)

  10. Full-scale testing of leakage of blast waves inside a partially vented room exposed to external air blast loading

    Science.gov (United States)

    Codina, R.; Ambrosini, D.

    2018-03-01

    For the last few decades, the effects of blast loading on structures have been studied by many researchers around the world. Explosions can be caused by events such as industrial accidents, military conflicts or terrorist attacks. Urban centers have been prone to various threats including car bombs, suicide attacks, and improvised explosive devices. Partially vented constructions subjected to external blast loading represent an important topic in protective engineering. The assessment of blast survivability inside structures and the development of design provisions with respect to internal elements require the study of the propagation and leakage of blast waves inside buildings. In this paper, full-scale tests are performed to study the effects of the leakage of blast waves inside a partially vented room that is subjected to different external blast loadings. The results obtained may be useful for proving the validity of different methods of calculation, both empirical and numerical. Moreover, the experimental results are compared with those computed using the empirical curves of the US Defense report/manual UFC 3-340. Finally, results of the dynamic response of the front masonry wall are presented in terms of accelerations and an iso-damage diagram.

  11. Comparison of athlete-coach perceptions of internal and external load markers for elite junior tennis training.

    Science.gov (United States)

    Murphy, Alistair P; Duffield, Rob; Kellett, Aaron; Reid, Machar

    2014-09-01

    To investigate the discrepancy between coach and athlete perceptions of internal load and notational analysis of external load in elite junior tennis. Fourteen elite junior tennis players and 6 international coaches were recruited. Ratings of perceived exertion (RPEs) were recorded for individual drills and whole sessions, along with a rating of mental exertion, coach rating of intended session exertion, and athlete heart rate (HR). Furthermore, total stroke count and unforced-error count were notated using video coding after each session, alongside coach and athlete estimations of shots and errors made. Finally, regression analyses explained the variance in the criterion variables of athlete and coach RPE. Repeated-measures analyses of variance and interclass correlation coefficients revealed that coaches significantly (P coach and athlete. However, athlete drill RPE (P = .14; r = .71) and mental exertion (P = .44; r = .68) were comparable and substantially correlated. No significant differences in estimated stroke count were evident between athlete and coach (P = .21), athlete notational analysis (P = .06), or coach notational analysis (P = .49). Coaches estimated significantly greater unforced errors than either athletes or notational analysis (P coach RPE was explained by intended session exertion and coach drill RPE, while drill RPE and peak HR explained 45.3% of the variance in athlete session RPE. Coaches misinterpreted session RPE but not drill RPE, while inaccurately monitoring error counts. Improved understanding of external- and internal-load monitoring may help coach-athlete relationships in individual sports like tennis avoid maladaptive training.

  12. 21 CFR 137.280 - Bolted yellow corn meal.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Bolted yellow corn meal. 137.280 Section 137.280... Flours and Related Products § 137.280 Bolted yellow corn meal. Bolted yellow corn meal conforms to the definition and standard of identity prescribed by § 137.255 for bolted white corn meal except that cleaned...

  13. Taub–Bolt heat engines

    Science.gov (United States)

    Johnson, Clifford V.

    2018-02-01

    It is shown that aspects of the extended thermodynamic properties of the Taub–Bolt–AdS spacetime in four dimensions are similar to those of the Schwarzschild–AdS black hole. In a high temperature expansion, the equations of state begin to deviate only at next-to-subleading orders. By analogy with what has been done for black holes, Taub–Bolt’s thermodynamic equations are used to define holographic heat engines, the first examples of gravitational heat engines defined using a spacetime that is not a black hole. As a further comparison, the Taub–Bolt engine efficiency is computed for two special kinds of engine cycle and compared to the results for analogous Schwarzschild black hole engine cycles.

  14. Monitoring Elite Soccer Players' External Loads Using Real-Time Data.

    Science.gov (United States)

    Barrett, Steve

    2017-11-01

    To assess the validity of measuring locomotor activities and PlayerLoad using real-time (RT) data collection during soccer training. Twenty-nine English soccer players participated. Each player wore the same MEMS device (Micromechanical Electrical Systems; S5, Optimeye; CatapultSports, Melbourne, Australia) during 21 training sessions (N = 331 data sets) in the 2015-16 and 2016-17 seasons. An RT receiver (TRX; Catapultsports, Melbourne, Australia) was used to collect the locomotor activities and PlayerLoad data in RT and compared with the postevent downloaded (PED) data. PlayerLoad and locomotor activities (total distance covered; total high-speed running distance covered, >5.5#x00A0;m/s; total sprinting distance covered, >7 m/s; maximum velocity) were analyzed. Correlations were near perfect for all variables analyzed (r = .98-1.00), with a varied level of noise between RT and PED also (0.3-9.7% coefficient of variation). Locomotor activities and PlayerLoad can use both RT and PED concurrently to quantify a player's physical output during a training session. Caution should be taken with higher-velocity-based locomotor activities during RT compared to PED.

  15. Computerized UT system for stud bolt

    International Nuclear Information System (INIS)

    Kisanuki, T.; Uchida, K.; Fushimi, T.; Onda, K.

    1988-01-01

    Cracking of stud bolts used in steam turbine casing, valve and pressure vessel has caused concern regarding the safety and reliability of power plants. In order to detect harmful cracks in early state, the improvement of UT technique is required. As regarding the ultrasonic inspection technique, a longitudinal beam technique and/or an angle beam technique are generally used. The authors report their development of a computerized UT system for bolt inspection and improvement of the angle beam technique

  16. An exploratory study of using external fluid loading on a vibrating tube for measuring suspended sediment concentration in water

    International Nuclear Information System (INIS)

    Hsu, Y-S; Hwang, Y-F; Huang, J H

    2008-01-01

    This paper presents an exploratory study of using external fluid loading on a vibrating tube for measuring the suspended sediment concentration (SSC) in bodies of water such as rivers and reservoirs. This new measuring concept provides an opportunity for an automated on-site monitoring of the conditions in a body of water by taking the fluid sample instantaneously in the area surrounding the vibrating tube. The physical properties of the fluid sample are those of the fluid that naturally flows around the tube, and are more representative of those of the water with SSC to be measured. The theoretical analysis presented in this paper shows that the resonance frequencies of an immersed vibrating tube change significantly with mass density variations that normally occur in bodies of water with suspended sediment. These changes are sensitive enough to have a possible 1% resolution of the measured fluid density. The signal processing issues are discussed, and a schematic of a conceptual measuring setup is proposed. Based on the theoretical analyses and other measurement issues presented in the paper, using the loading by external fluid on a vibrating tube is feasible for measuring the SSC in water bodies

  17. Crack nucleation in solid materials under external load - simulations with the Discrete Element Method

    Directory of Open Access Journals (Sweden)

    Klejment Piotr

    2018-01-01

    Full Text Available Numerical analysis of cracking processes require an appropriate numerical technique. Classical engineering approach to the problem has its roots in the continuum mechanics and is based mainly on the Finite Element Method. This technique allows simulations of both elastic and large deformation processes, so it is very popular in the engineering applications. However, a final effect of cracking - fragmentation of an object at hand can hardly be described by this approach in a numerically efficient way since it requires a solution of a problem of nontrivial evolving in time boundary conditions. We focused our attention on the Discrete Element Method (DEM, which by definition implies “molecular” construction of the matter. The basic idea behind DEM is to represent an investigated body as an assemblage of discrete particles interacting with each other. Breaking interaction bonds between particles induced by external forces imeditelly implies creation/evolution of boundary conditions. In this study we used the DEM approach to simulate cracking process in the three dimensional solid material under external tension. The used numerical model, although higly simplified, can be used to describe behaviour of such materials like thin films, biological tissues, metal coatings, to name a few.

  18. Behaviour of high stretch bolts in tension working as part of elements of steel structures, and their tendency to delayed fracturing

    Directory of Open Access Journals (Sweden)

    Moyseychik Evgeniy Alekseevich

    2014-12-01

    Full Text Available In the article, the author has proven that manufacturing and installation errors, as well as contact deformations of high strength bolts, if analyzed as part of tensile connections of steel structures, work in eccentric tension. In pursuance of the effective state standards, the analysis of these bolts is based on the axial tension. The author has analyzed the failure of a steel structure, caused by the fracture of eccentrically loaded bolts made of steel grade XC 42 (France, or C40 (Germany, that later followed the delayed fracturing pattern. The author provides the findings of the lab tests, whereby the above bolts were tested in the presence of an angle washer. The author has also analyzed the findings of low-temperature tests of bolts in tension. The author demonstrates that the strength of high strength bolts is driven by the material, the structure shape, and the thermal treatment pattern. Eccentric tension tests of bolts have proven that cracks emerge in the areas of maximal concentration of stresses (holes in shafts, etc. that coincide with the areas where fibers are in tension; cracks tend to follow the delayed fracturing pattern, and their development is accompanied by the deformation-induced metal heating in the fracture area. Therefore, the analysis of high strength bolts shall concentrate on the eccentric tension with account for contact-induced loads, while the tendency to delayed fracturing may be adjusted through the employment of both metallurgical and process techniques.

  19. Analyses of the dynamic behaviour of nuclear installation under external loads

    International Nuclear Information System (INIS)

    Alex, H.; Kaestle, H.J.; Kuntze, W.M.

    1976-04-01

    This paper demonstrates the dynamic analysis of a reactor building which is subject to earthquake loading. The purpose of this investigation is to calculate characteristic dynamical parameters at certain positions of the structure, such as floor time histories. Following the selection of a typical earthquake time history the reactor building is modelled with Finite Elements. The calculations are performed with the program system ASKA using Time History Modal Analysis. Prior to the response calculation the eigenvalue problem is solved. The results of the analysis, such as displacements, stresses and floor time histories will be discussed in view of the chosen earthquake excitation. (orig.) [de

  20. Direct Time Domain Numerical Analysis of Transient Behavior of a VLFS during Unsteady External Loads in Wave Condition

    Directory of Open Access Journals (Sweden)

    Yong Cheng

    2014-01-01

    Full Text Available The transient response of the VLFS subjected to arbitrary external load is systematically investigated by a direct time domain modal expansion method, in which the BEM solutions based on time domain Kelvin sources are used for hydrodynamic forces. In the analysis, the time domain free-surface Green functions with sufficient accuracy are rapidly evaluated in finite water depth by the interpolation-tabulation method, and the boundary integral equation with a quarter VLFS model is established taking advantage of symmetry of flow field and structure. The validity of the present method is verified by comparing with the time histories of vertical displacements of the VLFS during a mass drop and airplane landing and takeoff in still water conditions, respectively. Then the developed numerical scheme is used in wave conditions to study the combined action taking into account the mass drop/airplane landing/takeoff loads as well as incident wave action. It is found that the elevation of structural waves due to mass drop load can be significantly changed near the impact region, while the vertical motion of runway in wave conditions is dominant as compared with that only generated by airplane.

  1. Perspectives of roof bolt use in the Kuzbass

    Energy Technology Data Exchange (ETDEWEB)

    Shirokov, A P

    1983-10-01

    Use of roof bolting for strata control in mine roadways and underground chambers in Kuzbass mines is discussed. Use of roof bolting in the Kuzbass is increasing. In 1982 roof bolting was used in 50% of workings driven in the basin; in 15 coal mines roof bolting was the predominant method for strata control. Use of roof bolting rather than timber props permitted advance rate of mine drivage in the Kuzbass to be increased by 1.5-2.0 times. Interaction between roof bolts and rock strata is analyzed. The following bolt types are considered: timber roof bolts, steel expansion shell bolts and thread bar bolts. Bolt design is shown, along with methods for roof bolt installation in roadways and chambers. Roof bolting during level, inclined or steep seam mining, for strata control at junctions of working faces with gate roads, at junctions of 2 roadways, in coal chutes, in hydraulic mines, during thick seam slicing with hardening stowing and longwall mining with hydraulic stowing is analyzed. Effects of roof bolting on strata control efficiency in steep coal mines employing AShchM systems are evaluated.

  2. Analytical Investigation of the Cyclic Behavior of Smart Recentering T-Stub Components with Superelastic SMA Bolts

    Directory of Open Access Journals (Sweden)

    Junwon Seo

    2017-09-01

    Full Text Available Partially restrained (PR bolted T-stub connections have been widely used in replacement of established fully restrained (FR welded connections, which are susceptible to sudden brittle failure. These bolted T-stub connections can permit deformation, easily exceeding the allowable limit without any fracture because they are constructed with a design philosophy whereby the plastic deformation concentrates on bolt fasteners made of ductile steel materials. Thus, the PR bolted connections take advantage of excellent energy dissipation capacity in their moment and rotation behavior. However, a considerable amount of residual deformation may occur at the bolted connection subjected to excessive plastic deformation, thereby requiring additional costs to recover the original configuration. In this study, superelastic shape memory alloy (SMA bolts, which have a recentering capability upon unloading, are fabricated so as to solve these drawbacks, and utilized by replacing conventional steel bolts in the PR bolted T-stub connection. Instead of the full-scale T-stub connection, simplified T-stub components subjected to axial force are designed on the basis of a basic equilibrium theory that transfers the bending moment from the beam to the column and can be converted into equivalent couple forces acting on the beam flange. The feasible failure modes followed by corresponding response mechanisms are taken into consideration for component design with superelastic SMA bolts. The inelastic behaviors of such T-stub components under cyclic loading are simulated by advanced three-dimensional (3D finite element (FE analysis. Finally, this study suggests an optimal design for smart recentering T-stub components with respect to recentering and energy dissipation after observing the FE analysis results.

  3. Stress corrosion cracking susceptibility of selected materials for steam plant bolting applications

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, P.; Noga, J.O.; Ogundele, G.

    1996-12-01

    The incidence of alloy steel bolting failure in nuclear and fossil fired generating plants was discussed. The problem manifests itself in the form of intergranular stress corrosion cracking. A study was conducted to rank the susceptibility of three materials (Alloy AISI, type 4140, Alloy ASTM A564-92AXM 13 and Inconel 718) to stress corrosion cracking and to determine threshold stress intensity factors of currently used and alternate alloys in service environments typically encountered in steam generating utility plants. Although most alloy steel bolting failures have involved Cr-Mo, failures have also been reported for all the above mentioned materials. Attempts to minimize the occurrence of stress corrosion cracking have involved a ban on molybdenum disulphide, limiting bolt tightening torque and placing an upper limit on bolt hardness, and by correlation on tensile strength. Slow strain rate and wedge opening-loading specimen tests were used to evaluate commonly used and superior alternative bolting materials. Electrochemical polarization tests were also conducted. Threshold stresses in a H{sub 2}S environment were determined according to NACE standard TM-01-77. Results showed that, to a certain degree, all tested materials were susceptible to stress corrosion cracking. They ranked as follows from best to worst performance: (1) the Inconel 718, (2) alloy SM 13, and (3) alloy 4140. 9 refs., 20 tabs., 34 figs.

  4. A Study of the Bolt Connection System for a Concrete Barrier of a Modular Bridge

    Directory of Open Access Journals (Sweden)

    Doo-Yong Cho

    2018-04-01

    Full Text Available Modular technology has been recently studied to reduce the construction periods in the field of bridge construction. However, this method is restricted to the pier, girder, and deck, which are the main members of a bridge, and incidental facilities such as concrete barriers have been rarely studied. Thus, in this study, the connection system of a concrete barrier for modular bridges was developed, and a static loading experiment was performed to verify the structural capacity of the proposed system. The variables of the experiment were the vertical and horizontal bolt connections and the construction method. The barrier and plate were fabricated using match casting methods in which nuts were first inserted into the plates rather than anchor bolts using the conservative method. Moreover, a comparison with the conventional in situ barrier was also performed. The experiments were conducted according to the AASHTO LRFD standard. Consequently, the specimen using the vertical bolt connection had a structural capacity that was equal to 85% of that of the conventional specimen and exhibited similar crack patterns compared with the conventional specimen. In the case of the horizontal bolt connection, the separation in the connection area occurred with the application of the initial load and this specimen exhibited a poor performance because of the increase in the separation distance with the application of the maximum load.

  5. Match-play activity profile in professional soccer players during official games and the relationship between external and internal load.

    Science.gov (United States)

    Suarez-Arrones, L; Torreño, N; Requena, B; Sáez De Villarreal, E; Casamichana, D; Barbero-Alvarez, J C; Munguía-Izquierdo, D

    2015-12-01

    The aim was to quantify for the first time the physical and physiological profile of professional soccer players in official games using GPS and heart rate (HR) response. Thirty professional soccer players were investigated during a half in competitive club level matches (N.=348) using GPS devices. The relative total distance was 118.9±10.7 m∙min(-1) and player's Work-To-Rest Ratio was 2.1:1. Defenders covered the lowest total distance, while Second-Strikers (2(nd)S) and Wide-Midfielders (W-MD) traveled the greatest total distance. Defenders presented the lowest Work-To-Rest Ratio values. Playing position also impacted on all sprinting performance results, except in average sprint distance and time of sprint. The number of sprints and repeated-sprint sequences recorded by the W-MD and Strikers (S) were significantly greater than any other group. The average HR recorded was 87.1%HRmax and the relationship between the external and internal load value (Effindex) was 1.4 with significant differences in both between playing positions. W-MD recorded a significantly smaller average HR than any other group and Centre-Backs showed a significantly smaller Effindex value than any other group. Conversely, W-MD showed a significantly greater Effindex value than any other group, except the 2(nd)S. This study has verified a number of statistically significant differences between the different playing positions. Coaches should be focused on the specific physical and physiological requirements of the playing positions to optimize the training prescription in soccer. The relationships between external and internal load measures among position-specific indicates that players with less overall running performance during match-play were the worst in Effindex.

  6. TEM investigation of plant-irradiated NPP bolt material

    International Nuclear Information System (INIS)

    Pakarinen, J.; Ehrnsten, U.; Keinaenen, H.; Karlsen, W.; Karlsen, T.

    2015-01-01

    Analytical transmission electron microscopy (ATEM) was used to examine irradiation-induced damage in material removed from two different bolts from two different nuclear power plants. One section came from a French PWR, was made of CW AISI 316, and included a section of the bolt that had accumulated a dose of approximately 15 dpa during 19 operation cycles at 350 - 390 C. degrees. Another section came from a VVER bolt that was removed from the plant due to indications found in non-destructive examinations (NDE). The VVER bolt was made of solution annealed titanium stabilized 0X18H10T (corresponding to Type AISI 321) and had accumulated a fluence of 2.9 dpa. During the removal of that bolt, it was found that the bolt washer had been inappropriately spot welded to the shielding plate during assembly. Destructive investigations showed that the bolt had two large intergranular cracks, and the TEM samples were prepared from the material adjacent to those cracks. The PWR bolt had not failed, although cracks in the bolts with a similar history had been found previously. The fluence for the cold-worked AISI 316 PWR bolt was estimated to be about 15 dpa. Both the examined bolts showed a clear radiation induced segregation of alloying elements at the grain boundaries (GB-RIS), the presence of dislocation loops, the formation of precipitates, and linear deformation microstructures. Additionally, voids were found from the PWR bolt and the VVER bolt had a high density of dislocations. (authors)

  7. More Nuts and Bolts of Michaelis-Menten Enzyme Kinetics

    Science.gov (United States)

    Lechner, Joseph H.

    2011-01-01

    Several additions to a classroom activity are proposed in which an "enzyme" (the student) converts "substrates" (nut-bolt assemblies) into "products" (separated nuts and bolts) by unscrewing them. (Contains 1 table.)

  8. Development of a smart rock bolt for underground monitoring operations

    CSIR Research Space (South Africa)

    Moema, JS

    2003-07-01

    Full Text Available of magnetic methods in measuring the stress or microstructural transformation in an individual bolt in both laboratory and underground environment. The corrosion performance of the smart bolt alloy was evaluated in synthetic mine water and compared...

  9. Pneumatic wrench retains or discharges nuts or bolts as desired

    Science.gov (United States)

    Bouille, J. R.

    1966-01-01

    Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.

  10. Flight Testing and Real-Time System Identification Analysis of a UH-60A Black Hawk Helicopter with an Instrumented External Sling Load

    Science.gov (United States)

    McCoy, Allen H.

    1998-01-01

    Helicopter external air transportation plays an important role in today's world. For both military and civilian helicopters, external sling load operations offer an efficient and expedient method of handling heavy, oversized cargo. With the ability to reach areas otherwise inaccessible by ground transportation, helicopter external load operations are conducted in industries such as logging, construction, and fire fighting, as well as in support of military tactical transport missions. Historically, helicopter and load combinations have been qualified through flight testing, requiring considerable time and cost. With advancements in simulation and flight test techniques there is potential to substantially reduce costs and increase the safety of helicopter sling load certification. Validated simulation tools make possible accurate prediction of operational flight characteristics before initial flight tests. Real time analysis of test data improves the safety and efficiency of the testing programs. To advance these concepts, the U.S. Army and NASA, in cooperation with the Israeli Air Force and Technion, under a Memorandum of Agreement, seek to develop and validate a numerical model of the UH-60 with sling load and demonstrate a method of near real time flight test analysis. This thesis presents results from flight tests of a U.S. Army Black Hawk helicopter with various external loads. Tests were conducted as the U.S. first phase of this MOA task. The primary load was a container express box (CONEX) which contained a compact instrumentation package. The flights covered the airspeed range from hover to 70 knots. Primary maneuvers were pitch and roll frequency sweeps, steps, and doublets. Results of the test determined the effect of the suspended load on both the aircraft's handling qualities and its control system's stability margins. Included were calculations of the stability characteristics of the load's pendular motion. Utilizing CIFER(R) software, a method for near

  11. The baffle-barrel-bolting analysis program: evolution and technical accomplishments

    International Nuclear Information System (INIS)

    Schwirian, R.E.; Forsyth, D.R.; Snyder, M.D.; Bhandari, D.R.; Barsic, J.A.; Rabenstein, W.D.

    2001-01-01

    In Westinghouse pressurized water reactors (PWR) the reactor core is surrounded by baffle plates, which provide lateral restraint for the fuel assemblies at the core boundary. Baffle plates are attached to horizontal supports called former plates by baffle-former bolts. The formers are attached to the core barrel which also provides vertical support for the core. The B3 analysis program addresses the possibility of reduced baffle-former bolting in Westinghouse U.S. domestic plant designs with respect to the relevant design criteria. Since safety is the overriding motivation for the program, faulted events have received the most in-depth attention. This focus has been reinforced by the fact that the loads produced by the loss-of-coolant-accident (LOCA) have usually been the most limiting of all those considered. Consequently, much of the presentation below deals with the development of analysis techniques and acceptance criteria to demonstrate that LOCA-induced loads on the bolts and the fuel assemblies will be acceptable with significantly reduced baffle-former bolting. A discussion of the other faulted, normal, and upset analyses performed as part of the program will also be presented. (author)

  12. Energy Neutral Wireless Bolt for Safety Critical Fastening.

    Science.gov (United States)

    Seyoum, Biruk B; Rossi, Maurizio; Brunelli, Davide

    2017-09-26

    Thermoelectric generators (TEGs) are now capable of powering the abundant low power electronics from very small (just a few degrees Celsius) temperature gradients. This factor along with the continuously lowering cost and size of TEGs, has contributed to the growing number of miniaturized battery-free sensor modules powered by TEGs. In this article, we present the design of an ambient-powered wireless bolt for high-end electro-mechanical systems. The bolt is equipped with a temperature sensor and a low power RF chip powered from a TEG. A DC-DC converter interfacing the TEG with the RF chip is used to step-up the low TEG voltage. The work includes the characterizations of different TEGs and DC-DC converters to determine the optimal design based on the amount of power that can be generated from a TEG under different loads and at temperature gradients typical of industrial environments. A prototype system was implemented and the power consumption of this system under different conditions was also measured. Results demonstrate that the power generated by the TEG at very low temperature gradients is sufficient to guarantee continuous wireless monitoring of the critical fasteners in critical systems such as avionics, motorsport and aerospace.

  13. Energy Neutral Wireless Bolt for Safety Critical Fastening

    Directory of Open Access Journals (Sweden)

    Biruk B. Seyoum

    2017-09-01

    Full Text Available Thermoelectric generators (TEGs are now capable of powering the abundant low power electronics from very small (just a few degrees Celsius temperature gradients. This factor along with the continuously lowering cost and size of TEGs, has contributed to the growing number of miniaturized battery-free sensor modules powered by TEGs. In this article, we present the design of an ambient-powered wireless bolt for high-end electro-mechanical systems. The bolt is equipped with a temperature sensor and a low power RF chip powered from a TEG. A DC-DC converter interfacing the TEG with the RF chip is used to step-up the low TEG voltage. The work includes the characterizations of different TEGs and DC-DC converters to determine the optimal design based on the amount of power that can be generated from a TEG under different loads and at temperature gradients typical of industrial environments. A prototype system was implemented and the power consumption of this system under different conditions was also measured. Results demonstrate that the power generated by the TEG at very low temperature gradients is sufficient to guarantee continuous wireless monitoring of the critical fasteners in critical systems such as avionics, motorsport and aerospace.

  14. Stability of internal response and external load during 4-a-side football game in an indoor environment

    Directory of Open Access Journals (Sweden)

    Karel Hůlka

    2015-03-01

    Full Text Available Background: Small-sided games (SSG are spontaneous forms of specific training where exercise intensity can be manipulated mainly by modifying external factors. When using the SSG, there is a risk that the variability of intensity between players and on repetition of SSG may lead to some players training at inappropriate exercise intensities. Objective: The purpose of this study is to determine intra-individual repeatability and inter-individual variability in exercise intensity in small-sided 4on4 football games. Methods: Twenty five highly trained junior football players (age 17.68 ± 1.52 years; BMI 23.8 ± 1.92 kg . m-2 participated in the study. Distance covered (software package Video Manual Motion Tracker 1.0 and heart rate (HR, expressed as a percentage of peak heart rate were measured. All participants completed three measurements of 4-a-side games for three consecutive weeks. Results: The high intraclass correlation coefficient value (Heart rate [HR]: ICC = .88, 95% CI [.65, .94]; Distance covered [DC]: ICC = .76, 95% CI [.66, .96] implies a very high level of intra-individual repeatability. The Pearson's correlation coefficient value (HR: r = .93; DC: r = .85 indicates a high correlation between the results of any measurement. Bland and Altman's 95% limits of agreement were ± 10.32 beats . min-1 and ± 65.46 m of distance covered. Conclusions: The results of this study demonstrated that measured SSG elicit consistent heart rate responses and external load of the players.

  15. Inedible Nuts and Non-Lightning Bolts

    Science.gov (United States)

    Rynone, William

    2010-01-01

    In this article, the author provides detailed information on a wide variety of commonly used screws, bolts, and other fasteners. The information has been gathered in his engineering career and outside interests (maintenance on his car and airplane, and woodworking). The topic should be of interest to students and educators in many technical…

  16. Device for ultrasonic and eddy current testing of bolts

    International Nuclear Information System (INIS)

    Hromek, J.; Kaspar, P.

    1989-01-01

    The device provides pivoting fitting of the bolt of a WWER reactor steam generator while ultrasonic and eddy current probes are brought near. The bolt under study is clamped between a drive funnel and a securing cone. The eddy current probes are adjusted using guide arms to the point requested and are fitted over the bolt such as for their thread segments to engage the bolt thread. The ultrasonic transducers are then adjusted to the required point. The device can be used for testing bolts of a thread size from M54x5 and a maximum length of 600 mm. (J.B.). 1 fig

  17. A complex study on the reliability assessment of the containment of a PWR. Part III.- Structural reliability assessment under internal and external loading conditions

    International Nuclear Information System (INIS)

    Bauer, J.; Schueller, G.I.

    1977-01-01

    The first part of the analysis is concerned with the determination of the failure probability of the steel hull under internal load conditions. Two independent failure criteria are the basis for this calculation; the first one being the ultimate yield which is actually an instability condition and the second one being the fracture condition as described in Part II of the paper. Both the global and the local failure probabilities are investigated. The second part of the analysis is concerned with the external load case of earthquake. As it has already been described in Part I the probability of occurrence of a LOCA, given an earthquake has been considered in connection with the probable damage which the steel hull might experience during the earthquake. In other words the survival probability of the hull with deteriorated resistance is calculated, taking into account the frequencies of occurrence of the various events. The third part of the analysis is concerned with the reliability determination of the reinforced concrete dome structure, which is supposed to protect, the steel hull against external load conditions such as airplane crash and external pressure waves (the latter covering the load case of tornado occurrence). The reliability analysis of the reinforced concrete structure under earthquake loading is performed by utilizing the time-history method. Some aspects of the drawbacks of the response spectra method -when used in a risk analysis- are pointed out. The probability distribution of the concrete strength as determined under intermediate strain rate as described in Part II is utilized in the analysis. Finally the remaining two external load cases are discussed in light of their use in a reliability analysis and with respect to their frequency of occurrence and the probability distribution of their load intensities. The reliability demonstration is performed using the containment structure of the PWR-plant 'Biblis B' which is locate

  18. A Review of Rock Bolt Monitoring Using Smart Sensors

    Directory of Open Access Journals (Sweden)

    Gangbing Song

    2017-04-01

    Full Text Available Rock bolts have been widely used as rock reinforcing members in underground coal mine roadways and tunnels. Failures of rock bolts occur as a result of overloading, corrosion, seismic burst and bad grouting, leading to catastrophic economic and personnel losses. Monitoring the health condition of the rock bolts plays an important role in ensuring the safe operation of underground mines. This work presents a brief introduction on the types of rock bolts followed by a comprehensive review of rock bolt monitoring using smart sensors. Smart sensors that are used to assess rock bolt integrity are reviewed to provide a firm perception of the application of smart sensors for enhanced performance and reliability of rock bolts. The most widely used smart sensors for rock bolt monitoring are the piezoelectric sensors and the fiber optic sensors. The methodologies and principles of these smart sensors are reviewed from the point of view of rock bolt integrity monitoring. The applications of smart sensors in monitoring the critical status of rock bolts, such as the axial force, corrosion occurrence, grout quality and resin delamination, are highlighted. In addition, several prototypes or commercially available smart rock bolt devices are also introduced.

  19. A Review of Rock Bolt Monitoring Using Smart Sensors.

    Science.gov (United States)

    Song, Gangbing; Li, Weijie; Wang, Bo; Ho, Siu Chun Michael

    2017-04-05

    Rock bolts have been widely used as rock reinforcing members in underground coal mine roadways and tunnels. Failures of rock bolts occur as a result of overloading, corrosion, seismic burst and bad grouting, leading to catastrophic economic and personnel losses. Monitoring the health condition of the rock bolts plays an important role in ensuring the safe operation of underground mines. This work presents a brief introduction on the types of rock bolts followed by a comprehensive review of rock bolt monitoring using smart sensors. Smart sensors that are used to assess rock bolt integrity are reviewed to provide a firm perception of the application of smart sensors for enhanced performance and reliability of rock bolts. The most widely used smart sensors for rock bolt monitoring are the piezoelectric sensors and the fiber optic sensors. The methodologies and principles of these smart sensors are reviewed from the point of view of rock bolt integrity monitoring. The applications of smart sensors in monitoring the critical status of rock bolts, such as the axial force, corrosion occurrence, grout quality and resin delamination, are highlighted. In addition, several prototypes or commercially available smart rock bolt devices are also introduced.

  20. The ITER EC H and CD upper launcher: Design, analysis and testing of a bolted joint for the Blanket Shield Module

    Energy Technology Data Exchange (ETDEWEB)

    Gessner, Robby, E-mail: robby.gessner@kit.edu [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany); Aiello, Gaetano; Grossetti, Giovanni; Meier, Andreas [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany); Ronden, Dennis [DIFFER – Dutch Institute for Fundamental Energy Physics, P.O. Box 1207, NL-3430 BE Nieuwegein (Netherlands); Spaeh, Peter; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2013-10-15

    Highlights: ► The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint. ► The bolts were designed as “captive” in order to avoid their accidental removal from the joint. ► The bolted flange connection using two sets of 15 captive bolts (M22 × 2) placed along the sides. ► The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. -- Abstract: The final design of the structural system for the ITER EC H and CD upper launcher is in progress. Many design features of the preliminary design are under revision with the aim to achieve the built-to-print-status. This paper deals with design and analysis of a bolted joint for the Blanket Shield Module with special perspective on Remote Handling capability. The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint conceived so that in the Hot Cell Facility, RH maintenance can be performed on internal components. The joint must be capable to resist very high Electro-Magnetic loads from disruptions, while it has to sustain substantial thermal cycling during operation. Thus the need for a rigid and reliable design is essential. Beside the set of pre-stressed bolts the flanges were therefore equipped with additional shear keys to divert radial moments away from the bolts. Main focus of the work performed was the mechanical design of the joint and the assessment of the structural integrity with respect to the loads applied and its capability for maintenance by RH procedures. To fulfill a major aspect of the RH requirements, the bolts were designed as “captive” in order to avoid their accidental removal from the joint. The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. The final approval phase of

  1. The ITER EC H and CD upper launcher: Design, analysis and testing of a bolted joint for the Blanket Shield Module

    International Nuclear Information System (INIS)

    Gessner, Robby; Aiello, Gaetano; Grossetti, Giovanni; Meier, Andreas; Ronden, Dennis; Spaeh, Peter; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro

    2013-01-01

    Highlights: ► The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint. ► The bolts were designed as “captive” in order to avoid their accidental removal from the joint. ► The bolted flange connection using two sets of 15 captive bolts (M22 × 2) placed along the sides. ► The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. -- Abstract: The final design of the structural system for the ITER EC H and CD upper launcher is in progress. Many design features of the preliminary design are under revision with the aim to achieve the built-to-print-status. This paper deals with design and analysis of a bolted joint for the Blanket Shield Module with special perspective on Remote Handling capability. The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint conceived so that in the Hot Cell Facility, RH maintenance can be performed on internal components. The joint must be capable to resist very high Electro-Magnetic loads from disruptions, while it has to sustain substantial thermal cycling during operation. Thus the need for a rigid and reliable design is essential. Beside the set of pre-stressed bolts the flanges were therefore equipped with additional shear keys to divert radial moments away from the bolts. Main focus of the work performed was the mechanical design of the joint and the assessment of the structural integrity with respect to the loads applied and its capability for maintenance by RH procedures. To fulfill a major aspect of the RH requirements, the bolts were designed as “captive” in order to avoid their accidental removal from the joint. The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. The final approval phase of

  2. Developing a Magnetic Resonance Imaging measurement of the forces within 3D granular materials under external loads

    Science.gov (United States)

    Elrington, Stefan; Bertrand, Thibault; Frey, Merideth; Shattuck, Mark; O'Hern, Corey; Barrett, Sean

    2014-03-01

    Granular materials are comprised of an ensemble of discrete macroscopic grains that interact with each other via highly dissipative forces. These materials are ubiquitous in our everyday life ranging in scale from the granular media that forms the Earth's crust to that used in agricultural and pharmaceutical industries. Granular materials exhibit complex behaviors that are poorly understood and cannot be easily described by statistical mechanics. Under external loads individual grains are jammed into place by a network of force chains. These networks have been imaged in quasi two-dimensional and on the outer surface of three-dimensional granular materials. Our goal is to use magnetic resonance imaging (MRI) to detect contact forces deep within three-dimensional granular materials, using hydrogen-1 relaxation times as a reporter for changes in local stress and strain. To this end, we use a novel pulse sequence to narrow the line width of hydrogen-1 in rubber. Here we present our progress to date, and prospects for future improvements.

  3. Effects of Holding an External Load on the Standing Balance of Older and Younger Adults With and Without Chronic Low Back Pain.

    Science.gov (United States)

    Shigaki, Leonardo; Vieira, Edgar Ramos; de Oliveira Gil, André Wilson; Araújo, Cynthia Gobbi Alves; Carmargo, Mariana Zingari; Sturion, Leandro Amaral; de Oliveira, Marcio Roǵerio; da Silva, Rubens A

    2017-05-01

    The purpose of this study was to assess the effect of holding an external load on the standing balance of younger and older adults with and without chronic low back pain (CLBP). Twenty participants with and 20 without CLBP participated in the study. Each group contained 10 younger (50% men) and 10 older adults (50% men). Participants were instructed to look straight ahead while standing on a force platform during two 120-second trials with and without holding an external load (10% of body mass). The center of pressure area, mean velocity, and mean frequency in the anteroposterior and mediolateral directions were measured. Older adults had worse standing balance than younger adults did (P external load significantly increased postural instability for both age groups and CLBP status, with mean effect size across center of pressure variables of d = 0.82 for older participants without CLBP and d = 2.65 for younger participants without CLBP. These effects for people with CLBP were d = 1.65 for subgroup of older and d = 1.60 for subgroup of younger participants. Holding an external load of 10% of body mass increased postural instability of both younger and older adults with and without CLBP. Copyright © 2017. Published by Elsevier Inc.

  4. Research on Multiple-Split Load Sharing Characteristics of 2-Stage External Meshing Star Gear System in Consideration of Displacement Compatibility

    Directory of Open Access Journals (Sweden)

    Shuai Mo

    2017-01-01

    Full Text Available This paper studies the multiple-split load sharing mechanism of gears in two-stage external meshing planetary transmission system of aeroengine. According to the eccentric error, gear tooth thickness error, pitch error, installation error, and bearing manufacturing error, we performed the meshing error analysis of equivalent angles, respectively, and we also considered the floating meshing error caused by the variation of the meshing backlash, which is from the floating of all gears at the same time. Finally, we obtained the comprehensive angle meshing error of the two-stage meshing line, established a refined mathematical computational model of 2-stage external 3-split loading sharing coefficient in consideration of displacement compatibility, got the regular curves of the load sharing coefficient and load sharing characteristic curve of full floating multiple-split and multiple-stage system, and took the variation law of the floating track and the floating quantity of the center wheel. These provide a scientific theory to determine the load sharing coefficient, reasonable load distribution, and control tolerances in aviation design and manufacturing.

  5. Investigation of Fastening Performance of Subminiature Serrated Bolt

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Myung Guen; Jeong, Jin Hwan; Jang, Yeon Hui; Kim, Hee Cheol; Kim, Jong-Bong [Seoul Nat’l Univ. of Science & Tech, Seoul (Korea, Republic of)

    2017-04-15

    As the size of electric products such as mobile phones and smart watches decrease, the bolts used to assemble these products should also be miniaturized. A miniature-sized bolt has to provide sufficient joining torque and anti-releasing torque to keep the components together. We studied a serrated bolt as a candidate for a miniature-sized fastener to increase the anti-releasing torque. In a serrated bolt, a serrated shape is formed on the bottom surface of the bolt head to create an obstacle to releasing. In this study, finite element analyses for the joining and releasing of bolts were carried out, and the anti-releasing performance was predicted. Based on the results of analyses using various numbers of serrations and fastening depths, the effects of the number of serrations and fastening depth on the anti-releasing performance were investigated.

  6. Investigation of Fastening Performance of Subminiature Serrated Bolt

    International Nuclear Information System (INIS)

    Jang, Myung Guen; Jeong, Jin Hwan; Jang, Yeon Hui; Kim, Hee Cheol; Kim, Jong-Bong

    2017-01-01

    As the size of electric products such as mobile phones and smart watches decrease, the bolts used to assemble these products should also be miniaturized. A miniature-sized bolt has to provide sufficient joining torque and anti-releasing torque to keep the components together. We studied a serrated bolt as a candidate for a miniature-sized fastener to increase the anti-releasing torque. In a serrated bolt, a serrated shape is formed on the bottom surface of the bolt head to create an obstacle to releasing. In this study, finite element analyses for the joining and releasing of bolts were carried out, and the anti-releasing performance was predicted. Based on the results of analyses using various numbers of serrations and fastening depths, the effects of the number of serrations and fastening depth on the anti-releasing performance were investigated.

  7. A High-Order Theory for the Analysis of Circular Cylindrical Composite Sandwich Shells with Transversely Compliant Core Subjected to External Loads

    DEFF Research Database (Denmark)

    Rahmani, Omid; Khalili, S.M.R.; Thomsen, Ole Thybo

    2012-01-01

    A new model based on the high order sandwich panel theory is proposed to study the effect of external loads on the free vibration of circular cylindrical composite sandwich shells with transversely compliant core, including also the calculation of the buckling loads. In the present model......, which is based on a 3D elasticity solution for the core material, can be used as a benchmark in future studies of the free vibration and buckling of circular cylindrical composite sandwich shells with a transversely compliant core....

  8. 21 CFR 137.255 - Bolted white corn meal.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Bolted white corn meal. 137.255 Section 137.255... Flours and Related Products § 137.255 Bolted white corn meal. (a) Bolted white corn meal is the food prepared by so grinding and sifting cleaned white corn that: (1) Its crude fiber content is less than 1.2...

  9. ["Bolt projectiles" discharged from modified humane killers (author's transl)].

    Science.gov (United States)

    Pollak, S; Reiter, C

    1981-01-01

    Some common types of "humane killers" are supplied with rubber bushings and recoil springs holding back the bolt, which afterwards is rebound into the barrel. Removal of the rubber bush and withdrawal spring before firing can cause the bolt to break and become a free projectile. A suicide case is reported, in which a livestock stunner discharged a steel bolt penetrating the forehead and getting stuck in the skull.

  10. Alloy-steel bolting materials for special applications

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This specification covers regular and special-quality alloy steel bolting materials which may be used for nuclear and other special applications. Bolting materials as used in the specification cover rolled or forged bars, rotary pierced or extruded seamless tubes, bored bars, or forged hollows from forged or rolled bar segments to be machined into bolts, studs, washers, and nuts. Several grades of steel are covered and supplementary requirements of an optional nature are provided for use when special quality is desired

  11. Nuts and Bolts of the Ion Band State Theory

    Science.gov (United States)

    Chubb, Scott R.

    2005-12-01

    The nuts and bolts of our ion band state theory of low energy nuclear reactions (LENR's) in palladium-deuteride (PdD) and palladium-hydride (PdH) are the electrons that hold together or tear apart the bonds (or lack of bonds) between deuterons (d's) or protons (p's) and the host material. In PdDx and PdHx, this bonding is strongly correlated with loading. In ambient loading conditions (x ≲ 0.6), bonding inhibits ion band state occupation. As x → 1, slight increases and decreases in loading can induce "vibrations" (which have conventionally been thought to occur from phonons) that can induce potential losses or increases of p/d. Naive assumptions about phonons fail to include these losses and increases. These effects can occur because neither H or D has core electrons and because in either PdD or PdH, the electrons near the Fermi energy have negligible overlap with the nucleus of either D or H. In the past, implicitly, we have used these facts to justify our ion band state theory. Here, we present a more formal justification, based on the relationship between H(D) ion band states (IBS's) and H(D) phonons that includes a microscopic picture that explains why occupation of IBS's can occur in PdD and PdH and how this can lead to nuclear reactions.

  12. The dopamine receptor D4 gene and familial loading interact with perceived parenting in predicting externalizing behavior problems in early adolescence: the TRacking Adolescents' Individual Lives Survey (TRAILS).

    Science.gov (United States)

    Marsman, Rianne; Oldehinkel, Albertine J; Ormel, Johan; Buitelaar, Jan K

    2013-08-30

    Although externalizing behavior problems show in general a high stability over time, the course of externalizing behavior problems may vary from individual to individual. Our main goal was to investigate the predictive role of parenting on externalizing behavior problems. In addition, we investigated the potential moderating role of gender and genetic risk (operationalized as familial loading of externalizing behavior problems (FLE), and presence or absence of the dopamine receptor D4 (DRD4) 7-repeat and 4-repeat allele, respectively). Perceived parenting (rejection, emotional warmth, and overprotection) and FLE were assessed in a population-based sample of 1768 10- to 12-year-old adolescents. Externalizing behavior problems were assessed at the same age and 212 years later by parent report (CBCL) and self-report (YSR). DNA was extracted from blood samples. Parental emotional warmth predicted lower, and parental overprotection and rejection predicted higher levels of externalizing behavior problems. Whereas none of the parenting factors interacted with gender and the DRD4 7-repeat allele, we did find interaction effects with FLE and the DRD4 4-repeat allele. That is, the predictive effect of parental rejection was only observed in adolescents from low FLE families and the predictive effect of parental overprotection was stronger in adolescents not carrying the DRD4 4-repeat allele. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Investigation of the Chooz-A nuclear power plant bolts

    International Nuclear Information System (INIS)

    Monnet, I.; Decroix, G.M.; Dubuisson, P.; Reuchet, J.; Morlent, O.

    2002-01-01

    In Pressurised Water Reactor, some baffle-former bolts in austenitic stainless steel, are submitted to an important Intergranular cracking. This cracking may be attributed to the irradiation hardening during in pile service. As part of its concern of safety related to the ageing of the plant and, in particular, to the behaviour of the internals, IRSN wished to take part in the expertise Program on CHOOZ A power nuclear plant, within the framework of a convention with EDF, which provided the baffle-bolts. Examinations of these bolts, after 140 000 of in pile service, were carried out by the laboratories of the CEA. Hardness profiles were carried out on four bolts, which were irradiated at different doses, ranging from 0 to 22 dpa. The bolt of the core barrel, considered as unirradiated, shows a constant value of hardness, equal to the value of unirradiated material, all along the bolt and a slight increase in the head of the screw. The axial profile of hardness carried out on an irradiated bolt shows that there is a gradient of hardness between the most irradiated part (400 Hv) and the least irradiated part (270 Hv). The hardness of this bolt starts to evolve at 2.5 dpa and the maximum of hardening is reached for the most irradiated part (3.6 dpa). The hardness profile on the most irradiated bolt (between 10 and 22 dpa) indicate that hardness is homogeneous all along the bolt, 400 Hv. It confirms the existence of a threshold dose beyond which hardness does not vary any more, this threshold is estimated to be between 3.6 dpa and 10 dl Microstructural examinations of these bolts led us to conclude that hardening is correlated to dislocation microstructure. Indeed, the examination of the bolt of the core barrel confirms that this bolt is hardly unirradiated since the initial network of dislocations was not modified and that only some rare dislocation loops were observed. This is in agreement with hardness results showing no hardening of this bolt. On the two more

  14. Experimental Study on Shear Performance of Bolt in Roadway Supporting

    Directory of Open Access Journals (Sweden)

    D.J. Li

    2014-09-01

    Full Text Available The corner bolt is proved to be effective in the control of floor deformation of roadway, and the relevant studies on bolting mechanisms are of great significance in improving roadway stability. In this paper, two types of shear tests on six forms of bolts are performed by using self-designed shear test device, the electro-hydraulic servo triaxial testing system. The shear characteristics of different types of bolts are obtained. The results show that different bolt rods or different internal filling conditions result in large differences in shear resistance and different deformation adaptability. We find that the filling materials added can improve the shear performance of bolt significantly, and the bolt with steel not only can improve the strength of bolt body, but also has the bimodal characteristic that makes the bolt have the secondary bearing capacity and withstand larger deformation range during the process of shear, and shows a better support performance. Hoping to provide the experiment basis for support design and field application in the future.

  15. An Analytical Method for Determining the Load Distribution of Single-Column Multibolt Connection

    Directory of Open Access Journals (Sweden)

    Nirut Konkong

    2017-01-01

    Full Text Available The purpose of this research was to investigate the effect of geometric variables on the bolt load distributions of a cold-formed steel bolt connection. The study was conducted using an experimental test, finite element analysis, and an analytical method. The experimental study was performed using single-lap shear testing of a concentrically loaded bolt connection fabricated from G550 cold-formed steel. Finite element analysis with shell elements was used to model the cold-formed steel plate while solid elements were used to model the bolt fastener for the purpose of studying the structural behavior of the bolt connections. Material nonlinearities, contact problems, and a geometric nonlinearity procedure were used to predict the failure behavior of the bolt connections. The analytical method was generated using the spring model. The bolt-plate interaction stiffness was newly proposed which was verified by the experiment and finite element model. It was applied to examine the effect of geometric variables on the single-column multibolt connection. The effects were studied of varying bolt diameter, plate thickness, and the plate thickness ratio (t2/t1 on the bolt load distribution. The results of the parametric study showed that the t2/t1 ratio controlled the efficiency of the bolt load distribution more than the other parameters studied.

  16. Relative importance of expertise, lifting height and weight lifted on posture and lumbar external loading during a transfer task in manual material handling.

    Science.gov (United States)

    Plamondon, André; Larivière, Christian; Delisle, Alain; Denis, Denys; Gagnon, Denis

    2012-01-01

    The objective of this study was to measure the effect size of three important factors in manual material handling, namely expertise, lifting height and weight lifted. The effect of expertise was evaluated by contrasting 15 expert and 15 novice handlers, the effect of the weight lifted with a 15-kg box and a 23-kg box and the effect of lifting height with two different box heights: ground level and a 32 cm height. The task consisted of transferring a series of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables (moments) while expertise had low impact. On the other hand, expertise showed a significant effect of posture variables on the lumbar spine and knees. All three factors are important, but for a reduction of external back loading, the focus should be on the lifting height and weight lifted. The objective was to measure the effect size of three important factors in a transfer of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables but expertise was a major determinant in back posture.

  17. Lightweight structural design of a bolted case joint for the space shuttle solid rocket motor

    Science.gov (United States)

    Dorsey, John T.; Stein, Peter A.; Bush, Harold G.

    1988-01-01

    The structural design of a bolted joint with a static face seal which can be used to join Space Shuttle Solid Rocket Motor (SRM) case segments is given. Results from numerous finite element parametric studies indicate that the bolted joint meets the design requirement of preventing joint opening at the O-ring locations during SRM pressurization. A final design recommended for further development has the following parameters: 180 one-in.-diam. studs, stud centerline offset of 0.5 in radially inward from the shell wall center line, flange thickness of 0.75 in, bearing plate thickness of 0.25 in, studs prestressed to 70 percent of ultimate load, and the intermediate alcove. The design has a mass penalty of 1096 lbm, which is 164 lbm greater than the currently proposed capture tang redesign.

  18. Effect of hot dip galvanization on the fatigue strength of steel bolted connections

    Directory of Open Access Journals (Sweden)

    S.M.J. Razavi

    2017-07-01

    Full Text Available Hot dip galvanized steel bolted joints has been tested under fatigue loading to evaluate the effect of galvanizing coating on the fatigue strength of S355 structural steel. The experimental results showed that the decrease of the fatigue life of coated specimens in comparison with that of uncoated joints is very limited and the results are in good agreement with Eurocode detail category, without substantial reductions. The procedure for coating and preparation of the bolted joints is described in detail in this paper providing a useful tool for engineers involved in similar practical applications. The experimental results are compared with the previously published data on central hole notched galvanized and not treated specimens characterized by the same geometry.

  19. Analytical and numerical investigation of bolted steel ring flange connection for offshore wind monopile foundations

    Science.gov (United States)

    Madsen, C. A.; Kragh-Poulsen, J.-C.; Thage, K. J.; Andreassen, M. J.

    2017-12-01

    The monopile foundation is the dominant solution for support of wind turbines in offshore wind farms. It is normally grouted to the transition piece which connects the foundation to the turbine. Currently, the bolted steel ring flange connection is investigated as an alternative. The monopile--transition piece connection has specific problems, such as out-of-verticality and installation damage from driving the MP into the seabed and it is not fully known how to design for these. This paper presents the status of the ongoing development work and an estimate of what still needs to be covered in order to use the connection in practice. This involves presentation of an analytical and non-linear FE analysis procedure for the monopile-transition piece connection composed of two L flanges connected with preloaded bolts. The connection is verified for ultimate and fatigue limit states based on an integrated load simulation carried out by the turbine manufacturer.

  20. Is the internal training load different between starters and nonstarters volleyball players submitted to the same external load training? A case study

    Directory of Open Access Journals (Sweden)

    Thiago Andrade Goulart Horta

    2017-11-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n4p395   The same training stimulus can provide different physiological adaptations for athletes of the same team. Thus, the aim of this study was to analyze and compare the load training of starters and nonstarters players, athletes of a men’s volleyball team at different times of the season. The sample consisted of fifteen men’s volleyball superleague athletes who were divided into two groups of starters and nonstarters players. The training load of the ten weeks of the team’s preparation period for the main championship season in which no games were performed was selected for the study. The method of subjective perceived of effort (session-RPE proposed by Foster et al. (2001 was used to quantify the training load. The group of starters players had higher total weekly training load (TWTL and RPE values in the average of the ten weeks of training (p<0.05. Higher TWTL values for starters players in the preparatory and pre-competitive period compared to nonstarters players was also demonstrated (p<0.05. When different weeks were analyzed separately, weeks three and seven presented higher TWTL and RPE values for starters players compared with nonstarters players (p<0.05. The results presented in this study showed that starters players showed greater internal training load compared to nonstarters players.

  1. Structural analysis of closure bolts for shipping casks

    International Nuclear Information System (INIS)

    Mok, G.C.; Fischer, L.E.

    1993-04-01

    This paper identifies the active forces and moments in a closure bolt of a shipping cask. It examines the interactions of these forces/moments and suggest simplified methods for their analysis. The paper also evaluates the role that the forces and moments play in the structure integrity of the closure bolt and recommends stress limits and desirable practices to ensure its integrity

  2. Bolted Flanged Connection for Critical Plant/Piping Systems

    International Nuclear Information System (INIS)

    Efremov, Anatoly

    2006-01-01

    A novel type of Bolted Flanged Connection with bolts and gasket manufactured on a basis of advanced Shape Memory Alloys is examined. Presented approach combined with inverse flexion flange design of plant/piping joint reveals a significant increase of internal pressure under conditions of a variety of operating temperatures relating to critical plant/piping systems. (author)

  3. A study of high-strength bolts after dephosphoring

    Directory of Open Access Journals (Sweden)

    Shao-Yi Hsia

    2016-03-01

    Full Text Available A wide variety of fasteners are produced, including those for the automobile industry, household electrical appliances industry, architectural engineering, and even the aviation industry. The effects of the high-tensile bolt dephosphoring process on the entire fastener manufacturing process and its organizational characteristics and mechanical properties are analyzed and discussed in this study. Our experimental results reveal that the bolt dephosphoring process must be completed before heat treatment, which can be confirmed with a dephosphoring reagent or metallographic observation. Once bolt heat treatment is completed, bolts without dephosphoring appear to be coated with δ ferrite (delta ferrite composed of a phosphate coating and a phosphatizing coating, which are not easily removed. Heat treatment with phosphorus results in grain boundary segregation, causing embrittlement and a reduction in lattice bonding forces and resulting in a high risk of fracturing when bolts are used in high-temperature environments or undergo multiaxial stresses.

  4. Improvement in or relating to bolts or studs

    International Nuclear Information System (INIS)

    Seward, W.H.

    1977-01-01

    Reference is made to anti-seize bolts or studs for use in extreme conditions, such as in nuclear power plants. A number of methods have been proposed for avoiding seizure, but have met with limited success. One approach to this problem is to coat the surfaces of the steel bolt in such a way that the contacting surfaces of the bolt and its associated nut are sufficiently dissimilar for molecular seizure to be avoided. It has been discovered that greatly improved resistance to seizing can be obtained by hard plating the entire thread of an alloy steel bolt with Cr. After Cr plating the bolt is de-embrittled by suitable heat treatment. (U.K.)

  5. Reinforcement of Bolted Timber Joints Using GFRP Sheets in Poplar and Pine Woods

    Directory of Open Access Journals (Sweden)

    Mehrab Madhoushi

    2013-01-01

    Full Text Available Failure in timber structures occurs mainly in crucial points such as joints areas. Therefore, the idea of using composite sheets in timber joints has been intro-duced as a method in order to increase the strength and ductility behaviour of timber joints. This research aims to study the behaviour of bolted joints in poplar and pine woods, which are reinforced by two types of GFRP sheets. A single shear bolted joint consisted of 3 timber members whose length and width were 30 cm in length and 5 cm in width. The thickness of each member was 4 cm for internal part and 2 cm for external part. The employed steel bolt was 10 cm in length and 1 cm in diameter. In this respect, one layer of GFRP sheet was used to be bonded to timber members by using epoxy resin and left between the clamps for 24 hours. They were then kept at room temperature for three weeks. Also the effect of adding a wood veneer on the reinforced joints was investigated. The tensile strength of the reinforced and control samples (un-reinforced joints was measured according to ASTM D5652-92 standard. The results show that the reinforced samples have higher tensile strength compared to that of reinforced joints, although it is not statistically signifcant. Also, two types of sheets infuence the joint behaviour as the reinforced joints display more ductility behaviour.

  6. Performance of Link-To-Stub Bolted Connection in Column-Tree Moment Resisting Frames under Fire Conditions

    Directory of Open Access Journals (Sweden)

    Mahmood Yahyai

    2015-12-01

    Full Text Available Column-tree moment resisting frames, as the efficient shop-welded and field-bolted structural systems, are used in many countries. Very limited research has been carried out on such systems under fire conditions. This paper presents experimental investigations of the behavior of beam and bolted splice connections in steel column-tree moment resisting frames exposed to fire. Two full-scale steel sub-frames with different splice connections were tested under ISO 834 standard fire. The flange splice plates were configured as a single plate with single shear bolts in first specimen, and as double plates with double shear bolts in second specimen. The observation of thermal and structural fire behaviors including temperature histories, temperature-deflection of the beam, temperature-rotation of splice connections and failure modes were investigated. The temperature-deflection and temperature-rotation curves remained in the elastic range until about 600°C. Beyond 600°C, the behavior would be highly nonlinear plastic. The beam splice connection failed due to shear fracture of top bolts at temperatures beyond 750°C. Consequently, stub beam web failed at those temperatures because of block-shear. Using double plates with double shear bolts for flange splices would enhance the temperature resistance and rotational capacity of the beam splice connections. Both tests results confirmed that specimens retain the capacity to support the design load when the average beam temperature does not exceed 600°C. This temperature limit confirms the temperature criteria provided by ASTM E119 and ANSI/UL 263 for a restrained beam, and can be used to specify the minimum fire resistance criteria for beams in column-tree MRFs. The measured time-deflection curves showed that the restrained fire resistance rating for both unprotected specimens obtained about 15 minutes in both tests.

  7. Result from systematic compilation of barrel bolt findings in S/KWU type PWRs in the context of computational analysis

    International Nuclear Information System (INIS)

    Kilian, R.; Devrient, B.; Koenig, G.; Stanislowski, M.; Widera, M.; Beusekom, R. van; Wermelinger, T.

    2015-01-01

    In 2005 intergranular stress corrosion cracking (IGSCC) of barrel bolts was observed in several S/KWU type PWRs. The bolts, known as star bolts, are made of SS type 316 Ti (German Material No. 1.4571 K) bars which are cold worked to adjust the required mechanical properties. This damage mechanism was so far less understood for PWR primary conditions. Therefore an extended joint research program was launched by AREVA GmbH and VGB e.V. to clarify the specific conditions which contributed to the observed findings on barrel bolts. A systematic analysis of the IGSCC affecting parameters as material, heats, environment and mechanical load was performed based on a plant data compilation from all six S/KWU PWRs with comparable core barrel design using barrel and baffle bolts made from type 316Ti. Using the outcome of this systematic data compilation additional computational fluid dynamics calculations in combination with radiolysis calculations were performed. The results showed that by a combination of reduced volume exchange by local flow conditions and radiolysis reactions forming oxidizing species as dissolved oxygen and/or hydrogen peroxide may locally affect the corrosion behavior of cold worked austenitic stainless steels. Therefore, small local volumes with oxidizing water chemistry conditions are assumed to lead to the IGSCC of cold worked type 316Ti. The comparison of the initial cold worked microstructure by TEM with the cold worked and in service irradiated microstructure (void formation, dislocation loop density, etc.) clearly reveals that neutron irradiation hardening in terms of IASCC (Irradiation-Assisted Stress Corrosion Cracking) is not the leading mechanism for these cases of barrel bolt cracking in the analyzed PWRs. (authors)

  8. Evaluation of bolted connections in wood-plastic composites

    Science.gov (United States)

    Arnandha, Yudhi; Satyarno, Iman; Awaludin, Ali; Irawati, Inggar Septia; Ihsan, Muhamad; Wijanarko, Felyx Biondy; William, Mahdinur, Fardhani, Arfiati

    2017-03-01

    Wood-plastic composite (WPC) is a relatively new material that consists of sawdust and plastic polymer using the extrusion process. Due to its attributes such as low water content, low maintenance, UV durability and being fungi and termite resistant. Nowadays, WPC has already been produced in Indonesia using sawdust from local wood such as Albizia (Paraserianthes falcataria) and Teak (Tectona grandis). Moreover preliminary studies about the physical and mechanical WPC board from Albizia sawdust and HDPE plastic have been carried out. Based on these studies, WPC has a high shear strength around 25-30 MPa higher than its original wood shear strength. This paper was a part of the research in evaluating WPC as potential sheathing in a shear wall system. Since still little is known about connection behavior in WPC using Indonesian local wood, this study evaluated the connection for both of these two types of wood-plastic composite. WPC board from Albizia sawdust will be projected as shear wall sheathing and WPC stud from Teak sawdust projected to be shear wall frame. For this study, the embedding strength for both WPC was determined according to ASTM D 5764 standard, using two types of bolts (stainless bolt and standard bolt) with several diameters as variation (6 mm, 8 mm, 10 and 12 mm). Hence, dowel-bearing test under fastened condition conducted accordance to ASTM D5652, hereby the yield strength then compared with the prediction yield strength from European Yield Model (EYM). According to both single and double shear connection, it can be concluded that yield strength from the EYM method tended to under-predict the 5% diameter offset yield than the actual yield strength from the test. The yield strength itself increase with the increase of bolt diameter. For single shear connection, the highest yield strength was 12 mm standard bolt around 9732 N, slightly higher than stainless bolt around 9393 N. Whereby for double shear connection, the highest yield strength was

  9. Complication assessment and prevention strategies using midfoot fusion bolt for medial column stabilization in Charcot's osteoarthropathy

    DEFF Research Database (Denmark)

    Mehlhorn, Alexander T; Walther, Markus; Iblher, Niklas

    2016-01-01

    and stabilization using midfoot fusion bolt and lateral lag screws. Age, gender, presence of preoperative osteomyelitis or ulcer, number of complications and operative revisions, Hba1c value, consolidation of arthrodesis, presence of a load-bearing foot and period to bolt dislocation was assessed. The mean follow......-up was 21.4±14.6 (mean±SDM) months, 64% of patients suffered from diabetes with a preoperative Hba1c of 8.5±2.4. The mean number of revisions per foot was 3.6±4.1. Bolt dislocation was seen in 57% of the patients following 11.3±8.5 months; in 75% of these patients bony healing occurred before dislocation....... There was a significant association between preoperative increased Hba1c value, presence of preoperative ulcer and wound infection. Healing of arthrodesis was demonstrated in 57% and a permanent weight-bearing foot without recurrent ulcer was achieved in 79%. The early and late postoperative complications could...

  10. Failure Analysis Of The Bolt From Turn Table Tightening On The Heavy Lifting Equipment System

    International Nuclear Information System (INIS)

    Hatta, IIham

    2000-01-01

    This paper provides the results of failure analysis of the bolt from the turn table tightening which usually using on the heavy lifting equipment or as a equipment tor the material handling with the maximum load about 25 ton. The process of the failure analysis from the series of laboratory testing such as chemical composition, tensile testing, hardness, fracture surtace and microstructure. The results of the analysis we see this bolt have suffered fatigue failure and the initiation, cracking from the manufacture defect. This defect in the form like the folding on the screw surface which maybe happen at the screw forming process. This folding as a part of metal which not bonding together, so could act as a initial crack, and got the creasing of the strength too which cause from oxidation and decarburization at the moment of heat treatment process. So this material got the changein the strength too which oxidation and decarburization at the moment of heat treatment process. So this material got the change in the microstructure, from the martensite temper to the coarse ferrite and finally reduces the strength of the bolt

  11. European development Rock bolting; Desarrollo Europeo del Bulonaje

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    The project European Development Rockbolting which was developed during the period 1994-1997 and carried out within the OCICARBON Action Program (OCICARBON-ITGE agreement dated September 1, 1994, Code C-13-438) as well as within the framework of the Coal Technical research Program of the D. G. XVII of the EEC, n 7220/AB/143. The project has had the following external partners: DMT (Germany), BCC (UK) and CDF (France), and the collaboration of INERIS (France), RMT (UK) and GEOCONTROL S. A. (Spain). The objective of the investigation was to improve the techniques and design currently used in the application of rockbolts for supporting of both infrastructure and beds in the European coal mining. The most important result, besides that derived from the sharing of experiences and knowledge, was the technological design of a supporting system, which was carried out by each partner for the various proposed exploitations. The Spanish part carried out the works of designing and estimation of the bolting system corresponding to the exploitations of: -Carbones de Pedraforca SA. Saldes mine. -U. E. Provence. Pit Y. Morandat.

  12. Tapping and listening: a new approach to bolt looseness monitoring

    Science.gov (United States)

    Kong, Qingzhao; Zhu, Junxiao; Ho, Siu Chun Michael; Song, Gangbing

    2018-07-01

    Bolted joints are among the most common building blocks used across different types of structures, and are often the key components that sew all other structural parts together. Monitoring and assessment of looseness in bolted structures is one of the most attractive topics in mechanical, aerospace, and civil engineering. This paper presents a new percussion-based non-destructive approach to determine the health condition of bolted joints with the help of machine learning. The proposed method is very similar to the percussive diagnostic techniques used in clinical examinations to diagnose the health of patients. Due to the different interfacial properties among the bolts, nuts and the host structure, bolted joints can generate unique sounds when it is excited by impacts, such as from tapping. Power spectrum density, as a signal feature, was used to recognize and classify recorded tapping data. A machine learning model using the decision tree method was employed to identify the bolt looseness level. Experiments demonstrated that the newly proposed method for bolt looseness detection is very easy to implement by ‘listening to tapping’ and the monitoring accuracy is very high. With the rapid in robotics, the proposed approach has great potential to be implemented with intimately weaving robotics and machine learning to produce a cyber-physical system that can automatically inspect and determine the health of a structure.

  13. Reliability aspects of a composite bolted scarf joint. [in wing skin splice

    Science.gov (United States)

    Reed, D. L.; Eisenmann, J. R.

    1975-01-01

    The design, fabrication, static test, and fatigue test of both tension and compression graphite-epoxy candidates for a wing splice representative of a next-generation transport aircraft was the objective of the reported research program. A single-scarf bolted joint was selected as the design concept. Test specimens were designed and fabricated to represent an upper-surface and a lower-surface panel containing the splice. The load spectrum was a flight-by-flight random-load history including ground-air-ground loads. The results of the fatigue testing indicate that, for this type of joint, the inherent fatigue resistance of the laminate is reflected in the joint behavior and, consequently, the rate of damage accumulation is very slow under realistic fatigue loadings.

  14. Drop Tests Results Of Revised Closure Bolt Configuration Of The Standard Waste Box, Standard Large Box 2, And Ten Drum Overpack Packagings

    International Nuclear Information System (INIS)

    May, C.; Opperman, E.; Mckeel, C.

    2010-01-01

    The Transuranic (TRU) Disposition Project at Savannah River Site will require numerous transfers of radioactive materials within the site boundaries for sorting and repackaging. The three DOT Type A shipping packagings planned for this work have numerous bolts for securing the lids to the body of the packagings. In an effort to reduce operator time to open and close the packages during onsite transfers, thus reducing personnel exposure and costs, an evaluation was performed to analyze the effects of reducing the number of bolts required to secure the lid to the packaging body. The evaluation showed the reduction to one-third of the original number of bolts had no effect on the packagings capability to sustain vibratory loads, shipping loads, internal pressure loads, and the loads resulting from a 4-ft drop. However, the loads caused by the 4-ft drop are difficult to estimate and the study recommended each of the packages be dropped to show the actual effects on the package closure. Even with reduced bolting, the packagings were still required to meet the 49 CFR 178.350 performance criteria for Type A packaging. This paper discusses the effects and results of the drop testing of the three packagings.

  15. Construction method of pre assembled unit of bolt sphere grid

    Science.gov (United States)

    Hu, L. W.; Guo, F. L.; Wang, J. L.; Bu, F. M.

    2018-03-01

    The traditional construction of bolt sphere grid has many disadvantages, such as high cost, large amount of work at high altitude and long construction period, in order to make up for these shortcomings, in this paper, a new and applicable construction method is explored: setting up local scaffolding, installing the bolt sphere grid starting frame on the local scaffolding, then the pre assembled unit of bolt sphere grid is assembled on the ground, using small hoisting equipment to lift pre assembled unit to high altitude and install. Compared with the traditional installation method, the construction method has strong practicability and high economic efficiency, and has achieved good social and economic benefits.

  16. [Analysis of the results of the HIV-1, HCV and HBV viral load of SEIMC External Quality Control Program. Year 2014].

    Science.gov (United States)

    Medina González, Rafael; Orta Mira, Nieves; Guna Serrano, María Del Remedio; Latorre Martínez, José-Carlos; Gopegui, Enrique Ruiz de; Rosario Ovies, María; Poveda, Marta; Gimeno Cardona, Concepción

    2016-07-01

    Human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarizes the results obtained from the 2014 SEIMC (Spanish Society of Infectious Diseases and Clinical Microbiology) External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of 5 standards were sent. One standard consisted in seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (30.8% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 95.8% of laboratories reporting results within the limits (Δ quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  17. Strengthening of Reinforced Concrete Beam in Shear Zone by Compensation the Stirrups with Equivalent External Steel Plates

    Directory of Open Access Journals (Sweden)

    Khamail Abdul-Mahdi Mosheer

    2016-09-01

    Full Text Available An experimental study on reinforced concrete beams strengthened with external steel plates instead of shear stirrups has been held in this paper. Eight samples of the same dimensions and properties were used. Two of them were tested up to failure and specified as references beams; one with shear reinforcement and the other without shear reinforcement. Another samples without shear reinforcement were tested until the first shear crack occurs, then the samples strengthened on both sides with external steel plates as equivalent area of removed stirrups. The strengthened beams were divided into three groups according to the thickness of plates (1, 1.5, 2 mm, each group involved two beams; one bonded using epoxy and the other bonded using epoxy with anchored bolts. Finally, the strengthened beams tested when using anchored bolts with epoxy glue to bond plates. Where the increasing in maximum load is higher than that in reference beam with no internal stirrups reach to (75.46 –106.13% and has a good agreement with the control beam with shear reinforcement reach to (76.06 – 89.36% of ultimate load.

  18. Evaluation of structural reliability for vacuum vessel under external pressure and electromagnetic force

    International Nuclear Information System (INIS)

    Minato, Akio

    1983-08-01

    Static and dynamic structural analyses of the vacuum vessel for a Swimming Pool Type Tokamak Reactor (SPTR) have been conducted under the external pressure (hydraulic and atmospheric pressure) during normal operation or the electromagnetic force due to plasma disruption. The reactor structural design is based on the concept that the adjacent modules of the vacuum vessel are not connected mechanically with bolts in the torus inboard region each other, so as to save the required space for inserting the remote handling machine for tightenning and untightenning bolts in the region and to simplify the repair and maintenance of the reactor. The structural analyses of the vacuum vessel have been carried out under the external pressure and the electromagnetic force and the structural reliability against the static and dynamic loads is estimated. The several configurations of the lip seal between the modules, which is required to make a plasma vacuum boundary, have been proposed and the structural strength under the forced displacements due to the deformation of the vacuum vessel is also estimated. (author)

  19. Piezoelectric Washer for Accurate Application of Bolt Preload

    Data.gov (United States)

    National Aeronautics and Space Administration — A concept is proposed for monitoring bolt preload that offers accuracy and low-cost features not available in existing preload monitoring systems. Existing washer...

  20. Preloading of bolted connections in nuclear reactor component supports

    Energy Technology Data Exchange (ETDEWEB)

    Yahr, G T

    1984-10-01

    A number of failures of threaded fasteners in nuclear reactor component supports have been reported. Many of those failures were attributed to stress corrosion cracking. This report discusses how stress corrosion cracking can be avoided in bolting by controlling the maximum bolt preloads so that the sustained stresses in the bolts are below the level required to cause stress corrosion cracking. This is a basic departure from ordinary bolted joint design where the only limits on preload are on the minimum preload. Emphasis is placed on the importance of detailed analysis to determine the acceptable range of preload and the selection of a method for measuring the preload that is sufficiently accurate to ensure that the preload is actually within the acceptable range. Procedures for determining acceptable preload range are given, and the accuracy of various methods of measuring preload is discussed.

  1. Preloading of bolted connections in nuclear reactor component supports

    International Nuclear Information System (INIS)

    Yahr, G.T.

    1984-10-01

    A number of failures of threaded fasteners in nuclear reactor component supports have been reported. Many of those failures were attributed to stress corrosion cracking. This report discusses how stress corrosion cracking can be avoided in bolting by controlling the maximum bolt preloads so that the sustained stresses in the bolts are below the level required to cause stress corrosion cracking. This is a basic departure from ordinary bolted joint design where the only limits on preload are on the minimum preload. Emphasis is placed on the importance of detailed analysis to determine the acceptable range of preload and the selection of a method for measuring the preload that is sufficiently accurate to ensure that the preload is actually within the acceptable range. Procedures for determining acceptable preload range are given, and the accuracy of various methods of measuring preload is discussed

  2. Design Procedure on Stud Bolt for Reactor Vessel Assembly

    International Nuclear Information System (INIS)

    Kim, Jong-Wook; Lee, Gyu-Mahn; Jeoung, Kyeong-Hoon; Kim, Tae-Wan; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-01

    The reactor pressure vessel flange is welded to the upper part of reactor pressure vessel, and there are stud holes to mount the closure head with stud bolts. The surface mating the closure head is compressed with O-ring, which acts as a sealing gasket to prevent coolant leakage. Bolted flange connections perform a very important structural role in the design of a reactor pressure vessel. Their importance stems from two important functions: (a) maintenance of the structural integrity of the connection itself, and (b) prevention of leakage through the O-ring preloaded by stud bolts. In the present study, an evaluation procedure for the design of stud bolt is developed to meet ASME code requirements. The developed design procedure could provide typical references in the development of advanced reactor design in the future

  3. Design and operations of a load-tolerant external conjugate-T matching system for the A2 ICRH antennas at JET

    International Nuclear Information System (INIS)

    Monakhov, I.; Graham, M.; Blackman, T.; Dowson, S.; Durodie, F.; Jacquet, P.; Lehmann, J.; Mayoral, M.-L.; Nightingale, M.P.S.; Noble, C.; Sheikh, H.; Vrancken, M.; Walden, A.; Whitehurst, A.; Wooldridge, E.

    2013-01-01

    A load-tolerant external conjugate-T (ECT) impedance matching system for two A2 ion cyclotron resonance heating (ICRH) antennas was successfully put into operation at JET. The system allows continuous injection of the radio-frequency (RF) power into plasma in the presence of strong antenna loading perturbations caused by edge-localized modes (ELMs). Reliable ECT performance was demonstrated under a variety of antenna loading conditions including H-mode plasmas with radial outer gaps (ROGs) in the range 4–14 cm. The high resilience to ELMs predicted during the circuit simulations was fully confirmed experimentally. Dedicated arc-detection techniques and real-time matching algorithms were developed as a part of the ECT project. The new advanced wave amplitude comparison system has proven highly efficient in detection of arcs both between and during ELMs. The ECT system has allowed the delivery of up to 4 MW of RF power without trips into plasmas with type-I ELMs. Together with the 3 dB system and the ITER-like antenna, the ECT has brought the total RF power coupled to ELMy plasma to over 8 MW, considerably enhancing JET research capabilities. This paper provides an overview of the key design features of the ECT system and summarizes the main experimental results achieved so far. (paper)

  4. Usage of Cable Bolts for Gateroad Maintenance in Soft Rocks

    Directory of Open Access Journals (Sweden)

    Iurii Khalymendyk

    2014-01-01

    Originality/value: 1. There are no regulations and state standards in regard to cable bolt installation parameters in the mines of Ukraine, consequently the usage of cable bolts for gateroad maintenance required preliminary testing under geological conditions at the Western Donbass mines with soft enclosing rocks. 2. Combining levelling with observations using extensometers allowed for the detection of the rock layers' uniform sagging zone in the roof of the gateroad.

  5. Response surface reconciliation method of bolted joints structure

    Directory of Open Access Journals (Sweden)

    Yunus Mohd Azmi

    2017-01-01

    Full Text Available Structural joining methods such as bolted joints are commonly used for the assembly of structural components due to their simplicity and easy maintenance. Understandably, the dynamic characteristic of bolted joined structure is mainly influenced by the properties of their joints such as preload on the bolts and joints stiffness which alter the measured dynamics response of the structure. Therefore, the need to include the local effect of the bolted joints into the numerical model of the bolted joined structure is vitally important in order to represent the model accurately. In this paper, a few types of connector elements that can be used to represent the bolted joints such as CBAR, CBEAM and CELAS have been investigated numerically and experimentally. The initial numerical results of these element connectors are compared with the experimental results in term of natural frequencies and mode shapes. The comparative evaluation of numerical and the experimental data are performed in order to provide some insights of inaccuracies in the numerical model due to invalid assumption in the numerical modelling such as geometry, material properties, and boundary conditions. The discrepancies between both results (numerical and experimental data are then corrected using the response surface reconciliation method (RSRM through which the finite element model is altered in order to provide closer agreement with the measured data so that it can be used for subsequence analysis.

  6. INJECTION MOLDING AND STRUCTURAL ANALYSIS IN METAL TO PLASTIC CONVERSION OF BOLTED FLANGE JOINT BY CAE

    Directory of Open Access Journals (Sweden)

    Marian Blaško

    2014-12-01

    Full Text Available Many metal parts in various applications are being replaced by plastic parts. There are several reasons for that depending on actual application - minimize part cost, enhance corrosion resistance, integrating more components into one part etc. Most important steps of metal to plastic conversion are material selection and design of plastic part. Plastic part has to withstand the same load as metal part. To fulfill this requirement fiber reinforced engineering plastics are often used. Also it is convenient to substitute heavy wall sections with ribbed structure to increase load-carrying ability of part and decrease cycle time, eliminate voids, sink marks etc. Mechanical properties of such part could be highly affected by fiber orientation. Results of fiber orientation from injection molding filling analysis can be used in stress analysis for better prediction of part response to mechanical load. Such coupled analysis is performed here in this case study on bolted flange joint.

  7. Predicting the conditions under which vibroacoustic resonances with external periodic loads occur in the primary coolant circuits of VVER-based NPPs

    Science.gov (United States)

    Proskuryakov, K. N.; Fedorov, A. I.; Zaporozhets, M. V.

    2015-08-01

    The accident at the Japanese Fukushima Daiichi nuclear power plant (NPP) caused by an earthquake showed the need of taking further efforts aimed at improving the design and engineering solutions for ensuring seismic resistance of NPPs with due regard to mutual influence of the dynamic processes occurring in the NPP building structures and process systems. Resonance interaction between the vibrations of NPP equipment and coolant pressure pulsations leads to an abnormal growth of dynamic stresses in structural materials, accelerated exhaustion of equipment service life, and increased number of sudden equipment failures. The article presents the results from a combined calculation-theoretical and experimental substantiation of mutual amplification of two kinds of external periodic loads caused by rotation of the reactor coolant pump (RCP) rotor and an earthquake. The data of vibration measurements at an NPP are presented, which confirm the predicted multiple amplification of vibrations in the steam generator and RCP at a certain combination of coolant thermal-hydraulic parameters. It is shown that the vibration frequencies of the main equipment may fall in the frequency band corresponding to the maximal values in the envelope response spectra constructed on the basis of floor accelerograms. The article presents the results from prediction of conditions under which vibroacoustic resonances with external periodic loads take place, which confirm the occurrence of additional earthquake-induced multiple growth of pressure pulsation intensity in the steam generator at the 8.3 Hz frequency and additional multiple growth of vibrations of the RCP and the steam generator cold header at the 16.6 Hz frequency. It is shown that at the elastic wave frequency equal to 8.3 Hz in the coolant, resonance occurs with the frequency of forced vibrations caused by the rotation of the RCP rotor. A conclusion is drawn about the possibility of exceeding the design level of equipment vibrations

  8. A novel method for detecting second harmonic ultrasonic components generated from fastened bolts

    Science.gov (United States)

    Fukuda, Makoto; Imano, Kazuhiko

    2012-09-01

    This study examines the use of ultrasonic second harmonic components in the quality control of bolt-fastened structures. An improved method for detecting the second harmonic components, from a bolt fastened with a nut, using the transmission method is constructed. A hexagon head iron bolt (12-mm diameter and 25-mm long) was used in the experiments. The bolt was fastened using a digital torque wrench. The second harmonic component increased by approximately 20 dB before and after the bolt was fastened. The sources of second harmonic components were contact acoustic nonlinearity in the screw thread interfaces of the bolt-nut and were the plastic deformation in the bolt with fastening bolt. This result was improved by approximately 10 dB compared with previous our method. Consequently, usefulness of the novel method for detecting second harmonic ultrasonic components generated from fastened bolt was confirmed.

  9. Movement of the cervix in after-loading brachytherapy: implications for designing external-beam radiotherapy boost fields.

    Science.gov (United States)

    Hombaiah, U; Blake, P; Bidmead, M

    2006-05-01

    Women with invasive carcinoma of the cervix treated by chemo-radiotherapy and brachytherapy may also receive a pelvic sidewall boost using a midline shield (MLS). The purpose of this study was to assess the usefulness of implanted gold grains in detecting the movement of the cervix caused by the insertion of low-dose-rate brachytherapy applicators, and its implications in designing the MLS. The medical records of 42 women with various stages of cervical carcinoma, who were treated by radical chemo-radiotherapy, were reviewed. All of these women underwent examination under anaesthesia (EUA) and a gold-grain insertion to demarcate the vaginal tumour extent, in the antero-posterior and lateral planes, before starting external-beam radiotherapy. The isocentric orthogonal films (simulator films) of external radiotherapy and brachytherapy were compared to assess the change in position of the gold grains and the consequences for the design of the MLS for parametrial and pelvic sidewall boosts. A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. The median shift of the midline, right and left lateral gold grains was 4.5, 5 and 7 mm in the x axis, whereas it was 10, 8 and 9.5 mm in the y axis, respectively. The median shift in the x and y axes was 5.5 and 9 mm, ranging from 1 to 40 mm and 1 to 45 mm, respectively. The gold grains were shifted cranially in 34 (80%) and laterally in 29 (69%) women. Thirty-two women (76.2%) received parametrial boost radiotherapy, of which 25 (59.5%) women had a customised, pear-shaped shield, and the remaining seven (16.7%) had a straight-sided, rectangular MLS. Four women (9.5%) relapsed locally, and three of them had been treated using a customised shield. In two of these four women, there was an absolute under-dosage of the central pelvis at the tip of the intra-uterine tube by 50% of the parametrial boost dose (5.4 Gy/3 fractions/3 days). Insertion of the gold grains

  10. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    Science.gov (United States)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  11. Experimental study of bolted connections using light gauge channel sections and packing plates at the joints

    Science.gov (United States)

    Kulkarni, Ravindra B.; Vaghe, Vishal M.

    2014-12-01

    Cold-formed structural members are being used more widely in routine structural design as the world steel industry moves from the production of hot-rolled section and plate to coil and strip, often with galvanized and/or painted coatings. Steel in this form is more easily delivered from the steel mill to the manufacturing plant where it is usually cold-rolled into open and closed section members. In the present experimental study, the use of packing plate at the joints in cold-formed channel sections may increase the load carrying capacity and also reduce the buckling of unconnected cold form channel steel plate at joints. The present study focuses on examining the experimental investigation to use mild steel as a packing plate with cold-formed channel sections by bolted connection at the joints and the connection subjected to axial tension. Series of tests are carried out with increase in the thickness of packing plate and results are observed and analyzed. Total Twelve experimental tests have been carried out on cold-formed channel tension members fastened with single as well as three numbers of bolts at the connection and from the observations the strength of the joint is increased by increasing the various thicknesses of packing plates and also the buckling of unconnected leg of channel specimen is reduced. It is analyzed by plotting the entire load versus elongation path, so that the behavior of the connection is examined.

  12. A Probabilistic Approach to Baffle Bolt IASCC Predictions

    International Nuclear Information System (INIS)

    Griesbach, Timothy J.; Licina, George J.; Riccardella, Peter C.; Rashid, Joe R.; Nickell, Robert E.

    2012-01-01

    A methodology for evaluating the probability of baffle-former bolt cracking was developed for applicability to PWRs. The methodology is based upon IASCC test results for the stainless steels most commonly used for baffle-former bolts (e.g., Type 304 SA, Type 347 SA, and Type 316 CW) and predictions of the representative stress patterns in those bolts that were developed as inputs to the model. The predictive methodology for IASCC is based on a single parameter that was developed to incorporate the combined effects of dose and stress ratio (applied stress divided by yield strength, where the yield strength includes irradiation hardening) plus a Weibull statistical distribution that is defined in terms of that parameter. Baffle-former bolt cracking has been observed in a number of PWRs, and these incidents have raised concerns about the likelihood of future cracking or failures. In this damage model, IASCC 'failure' is defined when the component becomes fully susceptible to stress corrosion cracking; that is, after a certain level of irradiation and sustained stress. The length of time required for the material to become fully susceptible was determined from IASCC test data. IASCC crack initiation, which is defined to be equivalent to failure as noted above, is defined by an IASCC susceptibility curve from the test data that relates applied stress and cumulative neutron dose. The dose duration under constant stress is interpreted as the incubation time needed to make the material susceptible to stress corrosion cracking, after which crack initiation and propagation to full rupture under constant stress will occur within a relatively short time (hundreds of hours). The IASCC failure model uses the calculated stress in a material such as the baffle-former bolt and calculates a damage index as the ratio of the current applied stress to the allowable stress as a function of irradiation dose. IASCC initiation data for various irradiated bolting materials was obtained from

  13. An interactive roof bolting selection and performance system

    Energy Technology Data Exchange (ETDEWEB)

    Agioutantis, Z.; Stiakakis, C.; Stiakakis, N. [Technical Univ. of Crete, Chania (Greece); Karmis, M. [Virginia Polytechnic Inst. and State Univ. (United States)

    2001-07-01

    In the last decades, bolting has become one of the most dominant support methods in underground construction, including both mining as well as civil engineering applications. A variety of bolt types has been developed in order to meet the support needs of different geological and geotechnical settings. The selection of the appropriate bolt type, as well as the troubleshooting procedures in case of failure or suspected failure, are often complex and require extensive experience. To facilitate bolt type selection as well as troubleshooting, various tools have been presented in the form of nomograms, computer programs or trouble shooting guides. The approach described in this paper incorporates information and data developed by laboratory and field investigations and has led to the development of a dynamic knowledge base system that can aid in the selection of appropriate bolting systems and, also, help troubleshoot existing installations. Additionally, the user can enhance the functionality of the existing database with site-specific information and geological behavior as experienced by field personnel. The package is developed as a Windows trademark based application, where data is stored in Microsoft Access trademark database. (orig.)

  14. FLANGE-ORNL, Flanged Pipe Joint Stress Analysis, Internal Pressure, Moment Loads, Temperature

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1979-01-01

    1 - Description of problem or function: FLANGE-ORNL calculates appropriate loads, stresses, and displacements for the flanges, bolts, and gaskets that comprise a flanged piping joint for internal pressure or moment loading on the pipe, temperature difference between the flange hub and ring, and variations in bolt load that result from pressure, hub-ring temperature gradient and/or bolt-ring temperature differences. Flanges considered may be tapered-hub, straight or blind. 2 - Method of solution: The solution is based on discontinuity analysis and the theory of plates and shells

  15. Application of ultrasonic phased array technique for inspection of stud bolts in nuclear reactor vessel

    International Nuclear Information System (INIS)

    Choi, Sang Woo; Lee, Joon Ho; Park, Min Su; Cho, Youn Ho; Park, Moon Ho

    2004-01-01

    The stud bolt is one of crucial parts for safety of reactor vessels in nuclear power plants. Cracks initiation and propagation were reported in stud bolts using closure of reactor vessel and head. Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure and radioactive leakage from nuclear reactor. In conventional ultrasonic testing for inspection of stud bolts, crack was detected by using shadow effect. It take too much time to inspect stud bolt by using conventional ultrasonic technique. In addition, there were numerous spurious signal reflected from every thread. In this study, the advanced ultrasonic phased array technique was introduced for inspect stud bolts. The phased array technique provide fast inspection and high detectability of defects. There are sector scanning and linear scanning method in phased array technique, and these scanning methods were applied to inspect stud bolt and detectability was investigated.

  16. Development of plastic media blasting device for stud bolt

    International Nuclear Information System (INIS)

    Yoshihisa, Y.; Miyashita, T.

    1999-01-01

    Plastic media blasting is a mechanical cleaning method for removing paint, rust and/or anti-galling material etc on the surface of metal without damaging the metal surface. The method is suitable for cleaning the surface of reusable elements and parts such as bolts and nuts. Anti-galling material such as molybdenum disulfide is applied to fastening stud bolts used for the steam turbine rotor casing. It is necessary to remove this material when new anti-galling material is to be applied. Genden Engineering Services and Construction Co., and Morikawa Industries Corp., have developed a plastic media blasting device to clean the surface of stud bolt screw threads installed in the facility such as lower casing of the turbine. This paper reports the outline of the results. (author)

  17. Nuclear reactor incorporating locking device for threaded bolt connections

    International Nuclear Information System (INIS)

    Blaushild, R.M.

    1987-01-01

    A nuclear reactor having a pressure vessel and a first element is described comprising a core barrel situated within the pressure vessel. The core barrel has a baffle former secured in and to the core barrel by bolted connections, and a second element comprising baffle plates secured to the inner surface of the baffle former by bolted connections, with a locking device to prevent loosening of bolted connections between the baffle former and at least one of the elements. The baffle former and at least one element are held together by a headed, threaded bolt engaged in a bore coaxially extending in the baffle former and at least one element and threadedly engaged in a threaded section in at least the baffle former. The threaded section has first threaded of a first direction, with the head of the bolt engaged with a shoulder about the bore in at least one element to hold the baffle formed and at least one element together, the head of the bolt having a first diameter and a cavity, having an unsymmetrical wall thereabout, in the end surface thereof. It comprises a recess in at least one element coaxial with the bore forming a wall thereabout and extending inwardly from the outer surface of at least one element, the recess having a second diameter greater than the first diameter, with at least one element having second threads in the wall of a direction opposite the direction of the first threads of the threaded bore; a locking nut having a base with a downwardly depending cylindrical wall thereabout

  18. Mathematical representation of bolted-joint stiffness: A new suggested model

    Energy Technology Data Exchange (ETDEWEB)

    Haidar, Nawras; Obeed, Salwan; Jawad, Mohamed [College of Engineering, University of Babylon, Babel (Iraq)

    2011-11-15

    Joint member stiffness in a bolted connection directly influences the safety of a design in regard to both static and fatigue loading, as well as in the prevention of separation in the connection. This work provides a new simple model for computing the member stiffness in bolted connections for both fully and partially developed stress envelope fields. The new model is built using a stress distribution polynomial of third order. Finite element analysis (FEA) is performed for some joints geometries, and the results are used to estimate the best analytical envelope angle in the proposed analytical model that gives suitable convergence between the compared results. An experimental effort is exerted to validate the accuracy of a suggested model. When analytical results are compared with FEA results and experimental data, the maximum absolute percentage errors are found to be 2.69 and 14.69, respectively. Also, a good agreement is obtained when the analytical results are compared with other researchers' results.

  19. Seal performance of thermal aged metal gasket of dual purpose metal cask for interim spent fuel storage after external impact load

    International Nuclear Information System (INIS)

    Takeshi Yokoyama; Masami Kato; Satoshi Itooka

    2005-01-01

    As for interim storage for spent nuclear fuels using dual purpose dry metal cask in Japan, we recognize one of the important technical issues that there is a possibility for the cask with degraded metal gasket during storage to apply to transportation. In our study until 2003 focused on degradation of important components for the cask safety performance during storage and application to transportation, for metal gasket, we conducted property tests for degradation and influence of lid movement on seal performance, and furthermore verification tests. From the results, we developed the method to evaluate leak rate from lid with degraded metal gasket at accidents during transportation and in addition, we found as follows: Lid would hardly move and leak rate would not increase seriously during fire event. Leak rate from lid with degraded metal gasket could be evaluated by using results of leak rate trend depending on horizontal displacement of lid by external impact load. So, with regard to influence of lid movement on seal performance, we conducted additional test for extending horizontal displacement in lid moving in 2004. In addition, seal performance was discussed from the results, both previous and latest test. (authors)

  20. Design of Multiple Bolted Connections for Laminated Veneer Lumber

    Science.gov (United States)

    Borjen Yeh; Douglas Rammer; Jeff Linville

    2014-01-01

    The design of multiple bolted connections in accordance with Appendix E of the National Design Specification for Wood Construction (NDS) has incorporated provisions for evaluating localized member failure modes of row and group tear-out when the connections are closely spaced. Originally based on structural glued laminated timber (glulam) members made with all L1...

  1. Core Baffle Former Bolts Inspection and Repair at Farley NPP

    International Nuclear Information System (INIS)

    Marsat, E.

    1998-01-01

    As operating light water reactors are getting older and some of them are approaching their designed lifetime, the question of plant ageing, and the determination of their potential lifetime becomes mores and more important. This calls for a better understanding of ageing phenomena by an optimization of operating strategies and a development of innovative inspection and repair or replacement strategies. Definitely, this task is complex because it covers technical issues, cost, a given licensing situation and possibly, public acceptance. From a technical point it seems to be a common understanding that nuclear power plants can be operated for 40, 50 or even more years today. The inspection and repair technologies are of a very practical importance in achieving this goal. Bolts are subjected to flaws due to material, stress, and fluence issues. These issues are present in varying degrees depending on location in the core barrel. The issue depending on the number of failed bolts is a safety concern. It is not presently a concern if plants are operated with sufficient margin (sufficient acceptable bolts to allow continued operation). Historically there have been no greater than 10% of the bolts with detected flaws but as plants age, the flaw density may increase. (Author)

  2. Apparatus For Eddy-Current Inspection Of Bolts

    Science.gov (United States)

    Amos, Jay M.

    1994-01-01

    Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.

  3. STUDY, EVALUATION AND TEST OF SUBMODULE TO GIRDER BOLTED JOINT

    CERN Document Server

    Blocki, J; Miralles, Ll; Topilin, N D

    2000-01-01

    The object of the present work is to study the bolted joint submodule to girder. This joint is critical from the point of view of the mechanical integrity of the Tilecal Barrel and Extended Barrel modules and LAr Endcaps. Theoretical analysis, FEM calculations and tests have been carried out in order to find a solution that fulfils the safety factors design criteria.

  4. Bolting state-building fault lines with social capital

    African Journals Online (AJOL)

    2013-12-15

    Dec 15, 2013 ... Keywords: State-building, social capital, ethnic supremacy, Dinka, Nuer,. South Sudan. * Robert Gerenge is the Head of Special Programmes at the Electoral Institute for Sustainable. Democracy in Africa (EISA). South Sudan's December 2013 conflict: Bolting state-building fault lines with social capital.

  5. Analysis on Sealing Reliability of Bolted Joint Ball Head Component of Satellite Propulsion System

    Science.gov (United States)

    Guo, Tao; Fan, Yougao; Gao, Feng; Gu, Shixin; Wang, Wei

    2018-01-01

    Propulsion system is one of the important subsystems of satellite, and its performance directly affects the service life, attitude control and reliability of the satellite. The Paper analyzes the sealing principle of bolted joint ball head component of satellite propulsion system and discuss from the compatibility of hydrazine anhydrous and bolted joint ball head component, influence of ground environment on the sealing performance of bolted joint ball heads, and material failure caused by environment, showing that the sealing reliability of bolted joint ball head component is good and the influence of above three aspects on sealing of bolted joint ball head component can be ignored.

  6. Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2005-10-01

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on this information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. For the prediction of roof geology and stability condition in real time, a micro processor was used and a program developed to monitor and record the drilling parameters of roof bolter. These parameters include feed pressure, feed flow (penetration rate), rotation pressure, rotation rate, vacuum pressure, oil temperature of hydraulic circuit, and signals for controlling machine. From the results of a series of laboratory and underground tests so far, feed pressure is found to be a good indicator for identifying the voids/fractures and estimating the roof rock strength. The method for determining quantitatively the location and the size of void/fracture and estimating the roof rock strength from the drilling parameters of roof bolter was developed. Also, a set of computational rules has been developed for in-mine roof using measured roof drilling parameters and implemented in MRGIS (Mine Roof Geology Information System), a software package developed to allow mine engineers to make use of the large amount of roof drilling parameters for predicting roof geology properties automatically. For the development of roof bolting criteria, finite element models were developed for tensioned and fully grouted bolting

  7. Genetic analyses of bolting in bulb onion (Allium cepa L.).

    Science.gov (United States)

    Baldwin, Samantha; Revanna, Roopashree; Pither-Joyce, Meeghan; Shaw, Martin; Wright, Kathryn; Thomson, Susan; Moya, Leire; Lee, Robyn; Macknight, Richard; McCallum, John

    2014-03-01

    We present the first evidence for a QTL conditioning an adaptive trait in bulb onion, and the first linkage and population genetics analyses of candidate genes involved in photoperiod and vernalization physiology. Economic production of bulb onion (Allium cepa L.) requires adaptation to photoperiod and temperature such that a bulb is formed in the first year and a flowering umbel in the second. 'Bolting', or premature flowering before bulb maturation, is an undesirable trait strongly selected against by breeders during adaptation of germplasm. To identify genome regions associated with adaptive traits we conducted linkage mapping and population genetic analyses of candidate genes, and QTL analysis of bolting using a low-density linkage map. We performed tagged amplicon sequencing of ten candidate genes, including the FT-like gene family, in eight diverse populations to identify polymorphisms and seek evidence of differentiation. Low nucleotide diversity and negative estimates of Tajima's D were observed for most genes, consistent with purifying selection. Significant population differentiation was observed only in AcFT2 and AcSOC1. Selective genotyping in a large 'Nasik Red × CUDH2150' F2 family revealed genome regions on chromosomes 1, 3 and 6 associated (LOD > 3) with bolting. Validation genotyping of two F2 families grown in two environments confirmed that a QTL on chromosome 1, which we designate AcBlt1, consistently conditions bolting susceptibility in this cross. The chromosome 3 region, which coincides with a functionally characterised acid invertase, was not associated with bolting in other environments, but showed significant association with bulb sucrose content in this and other mapping pedigrees. These putative QTL and candidate genes were placed on the onion map, enabling future comparative studies of adaptive traits.

  8. A new design concept of fully grouted rock bolts in underground construction

    Science.gov (United States)

    Phich Nguyen, Quang; Nguyen, Van Manh; Tuong Nguyen, Ke

    2018-04-01

    The main problem after excavating an underground excavation is to maintain the stability of the excavation for a certain period of time. Failure in meeting this demand is a threat to safety of men and equipment. Support and reinforcement are different instruments with different mechanisms. Among the common support systems in tunnelling and mining, rock bolts have been widely used to reinforce rock mass and also to reduce geological hazards. Furthermore rock bolts can be applied under varying different geological conditions with cost-effectiveness. Although different methods are developed for grouted rock bolts design until now, the interaction mechanism of the rock bolts and rock mass is still very complicated issue. The paper addresses an analytical model for the analysis and design of fully grouted rock bolts based on the reinforcement principle. According to this concept the jointed rock mass reinforced by grouted rock bolts is considered as composite material which includes rock mass, the grout material and the bolt shank. The mechanical properties of this composite material depend on the ratio of the components. The closed-form solution was developed based on the assumption that the rock mass arround a circular tunnel remained elastic after installing fully grouted rock bolts. The main parameters of the rock-bolt system (the diameter and length of bolt shank, the space between the bolts) are then easily estimated from the obtained solution.

  9. Ageing management of baffle former bolts in Belgian nuclear power plants

    International Nuclear Information System (INIS)

    Somville, F.; Gerard, R.; Bosch, R.W.; Bertolis, D.; Vissers, S.

    2015-01-01

    The Pressurized Water Reactors internals support the reactor core, distribute the coolant flow through the core, and guide and protect the rod control cluster assemblies and in-core instrumentation. The baffle-to-former bolts are used in Pressurized Water Reactors to attach the baffle plates to the former plates in the reactor vessel lower internals. The resulting structure forms a boundary for the flow of coolant and provides lateral support to the fuel assemblies. Some edge bolts are also present, assembling together the baffle plates. After an operating time of the order of 120.000 hours, some bolts exhibit cracking at the junction of the head and the shank of the bolt. Examinations of failed bolts have made it possible to identify the cause of cracking as irradiation assisted stress corrosion cracking (IASCC). Up to now, baffle bolt cracking has been detected in units older than 15 years, where the baffle bolts are not cooled (no holes in the former to allow a water flow on the bolt shank). In Belgium, the concerned units are Tihange 1 and Doel 1-2. The paper summarizes the experience with baffle bolts cracking in Belgian units and the strategy implemented to mitigate this problem, consisting of structural integrity analyses, baffle bolts inspections and replacement, and research programs in the field of IASCC, including examinations of highly irradiated replaced bolts. (authors)

  10. Structural safety test and analysis of type IP-2 transport packages with bolted lid type and thick steel plate for radioactive waste drums in a NPP

    International Nuclear Information System (INIS)

    Kim, Dong Hak; Seo, Ki Seog; Lee, Sang Jin; Lee, Kyung Ho; Kim, Jeong Mook

    2007-01-01

    If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or disposal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions

  11. The dopamine receptor D4 gene and familial loading interact with perceived parenting in predicting externalizing behavior problems in early adolescence : The TRacking Adolescents' Individual Lives Survey (TRAILS)

    NARCIS (Netherlands)

    Marsman, Rianne; Oldehinkel, Albertine J.; Ormel, Johan; Buitelaar, Jan K.

    2013-01-01

    Although externalizing behavior problems show in general a high stability over time, the course of externalizing behavior problems may vary from individual to individual. Our main goal was to investigate the predictive role of parenting on externalizing behavior problems. In addition, we

  12. Numerical design and test on an assembled structure of a bolted joint with viscoelastic damping

    Science.gov (United States)

    Hammami, Chaima; Balmes, Etienne; Guskov, Mikhail

    2016-03-01

    Mechanical assemblies are subjected to many dynamic loads and modifications are often needed to achieve acceptable vibration levels. While modifications on mass and stiffness are well mastered, damping modifications are still considered difficult to design. The paper presents a case study on the design of a bolted connection containing a viscoelastic damping layer. The notion of junction coupling level is introduced to ensure that sufficient energy is present in the joints to allow damping. Static performance is then addressed and it is shown that localization of metallic contact can be used to meet objectives, while allowing the presence of viscoelastic materials. Numerical prediction of damping then illustrates difficulties in optimizing for robustness. Modal test results of three configurations of an assembled structure, inspired by aeronautic fuselages, are then compared to analyze the performance of the design. While validity of the approach is confirmed, the effect of geometric imperfections is shown and stresses the need for robust design.

  13. Micromechanics-Based Damage Analysis of Fracture in Ti5553 Alloy with Application to Bolted Sectors

    Science.gov (United States)

    Bettaieb, Mohamed Ben; Van Hoof, Thibaut; Minnebo, Hans; Pardoen, Thomas; Dufour, Philippe; Jacques, Pascal J.; Habraken, Anne Marie

    2015-03-01

    A physics-based, uncoupled damage model is calibrated using cylindrical notched round tensile specimens made of Ti5553 and Ti-6Al-4V alloys. The fracture strain of Ti5553 is lower than for Ti-6Al-4V in the full range of stress triaxiality. This lower ductility originates from a higher volume fraction of damage sites. By proper heat treatment, the fracture strain of Ti5553 increases by almost a factor of two, as a result of a larger damage nucleation stress. This result proves the potential for further optimization of the damage resistance of the Ti5553 alloy. The damage model is combined with an elastoviscoplastic law in order to predict failure in a wide range of loading conditions. In particular, a specific application involving bolted sectors is addressed in order to determine the potential of replacing the Ti-6Al-4V by the Ti5553 alloy.

  14. Efficient finite element modelling for the investigation of the dynamic behaviour of a structure with bolted joints

    Science.gov (United States)

    Omar, R.; Rani, M. N. Abdul; Yunus, M. A.; Mirza, W. I. I. Wan Iskandar; Zin, M. S. Mohd

    2018-04-01

    A simple structure with bolted joints consists of the structural components, bolts and nuts. There are several methods to model the structures with bolted joints, however there is no reliable, efficient and economic modelling methods that can accurately predict its dynamics behaviour. Explained in this paper is an investigation that was conducted to obtain an appropriate modelling method for bolted joints. This was carried out by evaluating four different finite element (FE) models of the assembled plates and bolts namely the solid plates-bolts model, plates without bolt model, hybrid plates-bolts model and simplified plates-bolts model. FE modal analysis was conducted for all four initial FE models of the bolted joints. Results of the FE modal analysis were compared with the experimental modal analysis (EMA) results. EMA was performed to extract the natural frequencies and mode shapes of the test physical structure with bolted joints. Evaluation was made by comparing the number of nodes, number of elements, elapsed computer processing unit (CPU) time, and the total percentage of errors of each initial FE model when compared with EMA result. The evaluation showed that the simplified plates-bolts model could most accurately predict the dynamic behaviour of the structure with bolted joints. This study proved that the reliable, efficient and economic modelling of bolted joints, mainly the representation of the bolting, has played a crucial element in ensuring the accuracy of the dynamic behaviour prediction.

  15. Behaviour of steel-concrete composite beams using bolts as shear connectors

    Science.gov (United States)

    Tran, Minh-Tung; Nguyen Van Do, Vuong; Nguyen, Tuan-Anh

    2018-04-01

    The paper presents an experimental program on the application of bolts as shear connectors for steel-composite beams. Four steel- concrete composite beams and a reference steel beam were made and tested. The aim of the testing program is to examine which forms of the steel bolts can be used effectively for steel-composite beams. The four types of the bolts include: Type 1 the bolt with the nut at the end; Type 2 the bolt bending at 900 hook; Type 3 the bolt without the nut at the end and Type 4 the bolt with the nut at the end but connected with the steel beam by hand welding in other to be connected with the steel beam by bolt connection as in the first three types. The test results showed that beside the traditional shear connectors like shear studs, angle type, channel type, bolts can be used effectively as the shear connectors in steel-composite beams and the application of bolts in Types 1 and 2 in the composite beams gave the better performance for the tested beam.

  16. Lower limit of strength wedge-type anchor bolts

    International Nuclear Information System (INIS)

    Arnedo Pena, A.; Frances Urmeneta, M.

    1998-01-01

    Simple expansion bolts, with a split expansion ring and a threaded bolt with an integral cone expander, called wedge type, are very used in securing and anchoring structures. The anchorage is obtained by a mechanism of torque-controlled expansion. Although less resistant than other types, its easy installation and low cost make them very competitive in light structures. In this paper, the minimum capacity values are analysed, when they are used to anchor safety-related equipment in NPP. The EPRI criteria developed in response to USI A-46 are applied and complemented by the new CEB Anchorage Design Guide. The results are compared with the information from european manufactures, adopting different safety factors for cracked and non-cracked concrete. With adequate control and inspection measures, including areas of noticeable cracking of concrete. minimum values for equipment can be obtained satisfying the strictest seismic validation requirements. (Author) 5 refs

  17. Regional Externalities

    NARCIS (Netherlands)

    Heijman, W.J.M.

    2007-01-01

    The book offers practical and theoretical insights in regional externalities. Regional externalities are a specific subset of externalities that can be defined as externalities where space plays a dominant role. This class of externalities can be divided into three categories: (1) externalities

  18. Pyroshock Prediction of Ridge-Cut Explosive Bolts Using Hydrocodes

    Directory of Open Access Journals (Sweden)

    Juho Lee

    2016-01-01

    Full Text Available Pyrotechnic release devices such as explosive bolts are prevalent for many applications due to their merits: high reliability, high power-to-weight ratio, reasonable cost, and more. However, pyroshock generated by an explosive event can cause failures in electric components. Although pyroshock propagations are relatively well understood through many numerical and experimental studies, the prediction of pyroshock generation is still a very difficult problem. This study proposes a numerical method for predicting the pyroshock of a ridge-cut explosive bolt using a commercial hydrocode (ANSYS AUTODYN. A numerical model is established by integrating fluid-structure interaction and complex material models for high explosives and metals, including high explosive detonation, shock wave transmission and propagation, and stress wave propagation. To verify the proposed numerical scheme, pyroshock measurement experiments of the ridge-cut explosive bolts with two types of surrounding structures are performed using laser Doppler vibrometers (LDVs. The numerical analysis results provide accurate prediction in both the time (acceleration and frequency domains (maximax shock response spectra. In maximax shock response spectra, the peaks due to vibration modes of the structures are observed in both the experimental and numerical results. The numerical analysis also helps to identify the pyroshock generation source and the propagation routes.

  19. Experimental study of friction in aluminium bolted joints

    Science.gov (United States)

    Croccolo, D.; de Agostinis, M.; Vincenzi, N.

    2010-06-01

    This study aims at developing an experimental tool useful to define accurately the friction coefficients in bolted joints and, therefore, at relating precisely the tightening torque to the bolt preloading force in some special components used in front motorbike suspensions. The components under investigation are some clamped joints made of aluminium alloy. The preloading force is achieved by applying a torque wrench to the bolt head. Some specific specimens have been appropriately designed and realized in order to study the tribological aspects of the tightening phase. Experimental tests have been performed by applying the Design of Experiment (DOE) method in order to obtain a mathematical model for the friction coefficients. Three replicas of a full factorial DOE at two levels for each variable have been carried out. The levels include cast versus forged aluminium alloy, anodized versus spray-painted surface, lubricated versus unlubricated screw, and first tightening (fresh unspoiled surfaces) versus sixth tightening (spoiled surfaces). The study considers M8x1.25 8.8 galvanized screws.

  20. Best practices for the design and installation of bolted joints

    Energy Technology Data Exchange (ETDEWEB)

    Tetteh-Wayoe, D. [Enbridge Pipelines Inc., Edmonton, AB (Canada)

    2004-07-01

    Bolted joints are often used in liquid pipeline facilities instead of welded joints because they must be frequently disassembled and reassembled as part of regular maintenance. Some bolted joints must retain their seal for the lifetime of the pipeline. As such, the design and installation practices used for bolted connections must have the same integrity as welded pipe. However, repeated flange leaks during hydrotesting has prompted an investigation into flange assembly practices. This paper addressed several aspects of proper flange assembly, including gaskets, lubricants, misalignment, hardened washers, studs and nuts, tools, torque values, tightening procedures, and quality control. A flange assembly procedure was then developed based on best practice recommendations. The objective was to eliminate flange leaks to reduce the effort needed during hydrotesting, and to create a seal that has the highest probability to last for the service life of the flange connection, regardless of service demands. It was concluded that obtaining the specified results depends highly on whether or not the personnel responsible for carrying out the work are well trained. Thirteen measures that can be implemented to improve the integrity of flange connections were listed. It was recommended that a regular review of flange assembly procedures should be performed with vendors, construction and operations personnel. Procedures should be updated when required. 12 refs., 5 tabs., 3 figs.

  1. Failure Analysis on Tail Rotor Teeter Pivot Bolt on a Helicopter

    Science.gov (United States)

    Qiang, WANG; Zi-long, DONG

    2018-03-01

    Tail rotor teeter pivot bolt of a helicopter fractured when in one flight. Failure analysis on the bolt was finished in laboratory. Macroscopic observation of the tailor rotor teeter pivot bolt, macro and microscopic inspection on the fracture surface of the bolt was carried out. Chemical components and metallurgical structure was also carried out. Experiment results showed that fracture mode of the tail rotor teeter pivot bolt is fatigue fracture. Fatigue area is over 80% of the total fracture surface, obvious fatigue band characteristics can be found at the fracture face. According to the results were analyzed from the macroscopic and microcosmic aspects, fracture reasons of the tail rotor teeter pivot bolt were analyzed in detail

  2. Ultrasonic Phased Array Techniques for Detection of Flaws of Stud Bolts in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Joon Hyun; Choi, Sang Woo

    2006-01-01

    The reactor vessel body and closure head are fastened with the stud bolt that is one of crucial parts for safety of the reactor vessels in nuclear power plants. It is reported that the stud bolt is often experienced by fatigue cracks initiated at threads. Stud bolts are inspected by the ultrasonic technique during the overhaul periodically for the prevention of failure which leads to radioactive leakage from the nuclear reactor. The conventional ultrasonic inspection for stud bolts was mainly conducted by reflected echo method based on shadow effect. However, in this technique, there were numerous spurious signals reflected from every oblique surfaces of the thread. In this study, ultrasonic phased array technique was applied to investigate detectability of flaws in stud bolts and characteristics of ultrasonic images corresponding to different scanning methods, that is, sector and linear scan. For this purpose, simplified stud bolt specimens with artificial defects of various depths were prepared

  3. A Mathematical Model for Temperature Induced Loosening due to Radial Expansion of Rectangle Thread Bolted Joints

    Directory of Open Access Journals (Sweden)

    Shiyuan Hou

    2015-01-01

    Full Text Available This paper proposed a mathematical model to investigate the radial expansion induced loosening of rectangle thread bolted joints that were subjected to cyclic temperature variation, which could cause slippage between contact pairs of engaged threads and bolt bearing. Firstly, integral equations were derived for the shear stress components caused by expansion difference, as well as the bearing and thread friction torque components, which depended on the temperature variation. Secondly, the relationship of displacement components was developed based on quasi-static hypotheses. Then, treating the rotation of bolt as plastic elongation, the bolt tension's evolution was obtained by using a one-dimensional bolted joint model. Numerical results showed that the temperature variation decreased the bearing and thread friction torque components, which could lead bolted joint to loosen. Finally, the effects of some associated factors on the progress were discussed.

  4. Effects of Head Size on the Performance of Twist-Off Bolts

    OpenAIRE

    Schnupp, Keith Otto

    2003-01-01

    This study examines a specific application of button-head type twist-off bolts. Currently, the Research Council on Structural Connections Specification (2000) removes the requirement for ASTM F436 washers (ASTM 2000a) under the bolt head of twist-off bolts where the head diameter equals or exceeds that of an ASTM F436 washer when oversized and slotted holes are used. The need for washers is also removed for A490 strength bolts used on steels with specified yield strengths less than 40 ksi p...

  5. Evaluation of long-term relaxation for high-strength bolted connections

    International Nuclear Information System (INIS)

    Nah, H. S.; Lee, H. J.; Kim, K. S.

    2010-01-01

    It is general that the clamping forces of high-strength bolts diminish within a certain time period after the initial clamping force. In case that special treatments are applied on a faying surface, the clamping force is relaxed severely. Tests were conducted for slip critical joints subjected to various faying surface parameters. The candidates for bolt were two kinds: Korean Standard and American Standard. Relaxation occurred for slip resistant joints with an uncoated surface that had been shot-blasted, cleaned, milled or rusted. In case of ASTM hexagon bolts, the initial clamping force dropped from 7.9% to 13.6% after 1, 000 hours while relaxation ratio was the range from 8.7% to 15.4% for KS bolts. For ASTM hexagon bolt joints with a 5 mil thick zinc coating, the clamping force of the bolts decreased 15.0%, while relaxation ratio was 12.85% for KS bolts. For 4.9 mil thick red lead painted treatment, the relaxation ratio was 18.7% for ASTM hexagon bolt, 34.9% for KS bolts. Regardless of faying surface treatments, the first week charged at least 86% of total relaxation from this test. (authors)

  6. Post-Service Examination of PWR Baffle Bolts, Part I. Examination and Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sokolov, Mikhail A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-04-30

    In support of extended service and current operations of the US nuclear reactor plants, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, is coordinating with Ginna Nuclear Power Plant, The Westinghouse Electric Company, LLC, and ATI Consulting, the selective procurement of baffle bolts that were withdrawn from service in 2011 and currently stored on site at Ginna. The goal of this program is to perform detailed microstructural and mechanical property characterization of baffle former bolts following in-service exposures. This report outlines the selection criteria of the bolts and the techniques to be used in this study. The bolts available are the original alloy 347 steel fasteners used in holding the baffle plates to the baffle former structures within the lower portion of the pressurized water reactor vessel. Of the eleven possible bolts made available for this work, none were identified to have specific damage. The bolts, however, did show varying levels of breakaway torque required in their removal. The bolts available for this study varied in peak fluence (highest dose within the head of the bolt) between 9.9 and 27.8x1021 n/cm2 (E>1MeV). As no evidence for crack initiation was determined for the available bolts from preliminary visual examination, two bolts with the higher fluence values were selected for further post-irradiation examination. The two bolts showed different breakaway torque levels necessary in their removal. The information from these bolts will be integral to the LWRS program initiatives in evaluating end of life microstructure and properties. Furthermore, valuable data will be obtained that can be incorporated into model predictions of long-term irradiation behavior and compared to results obtained in high flux experimental reactor conditions. The two bolts selected for the ORNL study will be shipped to Westinghouse with bolts of

  7. Review of Bolt Preload and Torque for Assembling Threaded Fasteners in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lee, Yong-Sung; Lee, Jae-Gon; Kang, Yong-Chul; Shin, Ki-Jong

    2007-01-01

    There are numerous threaded fasteners such as bolts, studs, nuts, cap screws and anchor bolts used in nuclear power plants(NPPs). The major applications of threaded fasteners are reactor coolant pressure boundary components, their internals and supports. With the increase of commercial operation period of NPPs, the incidents caused by degradation of threaded fasteners have been occurred. A large number of reported incidents are involved in the pressure boundary and major component supports. The degradation and failure of threaded fasteners is affected by material, preload and torque value at assembly, bolting practice, etc. It is very important to select appropriate bolt preload and decide assembly torque value because torque control using a torque wrench is the most common method in a power plant to assemble a bolted flange connection. Many researches have been studied to define the proper bolt preload and desired torque value with regard to the integrity of bolted connections including pressure boundary joints by EPRI and other plant industry. But in domestic NPPs, considerably few works are done on the bolted joint assembly in spite of increasing events related with threaded faster. Therefore we investigated degradation or failure of the threaded fasteners used in NPPs, also examined the codes, standards and technical trends concerning bolt preload and assembly torque in NPPs. It is the purpose of this study to provide proper technical information for assuring integrity of the threaded fasteners

  8. Analysis of the Seismic Performance of Site-Bolted Beam to Column Connections in Modularized Prefabricated Steel Structures

    Directory of Open Access Journals (Sweden)

    Xuechun Liu

    2017-01-01

    Full Text Available This paper proposes a site-bolted connection that is suitable for modularized prefabricated steel structures. Excellent ductility is achieved by various structural measures. Six connection specimens with different parameters were subjected to quasi-static loading tests and finite element analysis (FEA to determine the seismic performance of the proposed connection (e.g., hysteretic behavior, skeleton curve, ductility, and failure mode. The results of the tests and FEA showed that the connection underwent sufficient plastic deformation under cyclic loading and that its ultimate rotation angle could reach 0.09 rad. A clear plastic hinge formed on the beam before the connection failed, which suggests a ductile failure mode. The connection exhibited a wide hysteresis loop, which indicated good seismic performance. The results also showed that the connection does not slip under small earthquakes and could dissipate energy through slippage in the connection region under a moderate earthquake and through slippage in the connection region as well as plastic deformation at the beam end under a severe earthquake. The number of bolts was the main parameter that affected the seismic performance of the connection. The test and FEA results demonstrated that all six specimens had excellent seismic and ductile performance and an exceptional plastic rotation capacity.

  9. Design and Analytical Evaluation of a New Self-Centering Connection with Bolted T-Stub Devices

    Directory of Open Access Journals (Sweden)

    Mahbobeh Mirzaie Aliabadi

    2013-01-01

    Full Text Available A new posttensioned T-stub connection (PTTC for earthquake resistant steel moment resisting frames (MRFs is introduced. The proposed connection consists of high strength posttensioned (PT strands and bolted T-stubs. The post-tensioning strands run through the column and are anchored against the flange of the exterior column. The T-stubs, providing energy dissipation, are bolted to the flange of beam and column and no field welding is required. The strands compress the T-stub against the column flange to develop the resisting moment to service loads and to provide a restoring force that returns the structure to its initial position following an earthquake. An analytical model based on fiber elements is developed in OpenSees to model PTTCs. The analytical model can predict the expected behavior of the new proposed connection under cyclic loading. PTTC provides similar characteristic behavior of the posttensioned connections. Both theoretical behavior and design methods are proposed, and the design methods are verified based on parametric studies and comparison to analytical results. The parametric studies prove the desired self-centering behavior of PTTC and show that this connection can reduce or eliminate the plastic rotation by its self-centering behavior as well as providing required strength and stiffness under large earthquake rotations.

  10. Metallurgical examinations update of baffle bolts removed from operating French PWR. Microstructural investigations of a baffle to former bolt located on a high level of the internal structures

    International Nuclear Information System (INIS)

    Panait, C.; Fargeas, E.; Miloudi, S.; Moulart, P.; Tommy-Martin, M.; Monteil, N.; Pokor, C.

    2015-01-01

    This paper presents the microstructural investigations conducted on a cracked baffle to former bolt extracted from an upper former level of the internal structures of a French Pressurized Water Reactor (PWR). Extensive microstructural investigations using Light Microscopy, Scanning Electron Microscopy and Transmission Electron Microscopy (TEM) have been conducted to understand the degradation mechanisms of this bolt. TEM investigations have revealed neutron irradiation damage in the microstructure of the bolt such as Frank loops and cavities and/or bubbles. The number of features per unit volume as a function of diameter was determined in the head and in the shank of the bolt. The obtained results are relatively similar to those obtained for other damaged bolts extracted from PWR-type reactors and irradiated in similar conditions (dose and temperature). The irradiation damage has induced an evolution of the mechanical properties (hardening of the material), as revealed by the hardness measurements along the bolt, with a higher average value in the head (400 HV), compared to the shank (15 mm under the head), about 340 HV. The metallurgical investigations have confirmed that this bolt was damaged by Irradiation Assisted Stress Corrosion Cracking (IASCC)

  11. In situ ultrasonic examination of high-strength steam generator support bolts

    International Nuclear Information System (INIS)

    Jusino, A.

    1985-01-01

    Currently employed high-strength steam generator support bolting material (designed prior to ASME Section III Part NF or Component Supports), 38.1 mm in diameter, in combination with high preloads are susceptible to stress corrosion cracking because of the relatively low stress corrosion resistance (K/sub ISCC/) properties. These bolts are part of the pressurized water reactor steam generator supports at the integral support pads (three per steam generator, with each pad housing six, eight, or ten bolts depending on the design). The US Nuclear Regulatory Commission concerns for high-strength bolting were identified in NUREG-0577, ''Potential for Low Fracture Toughness and Laminar Tearing in PWR Steam Generator and Reactor Coolant Pump Supports,'' which was issued for comment on unresolved safety issue A-12. Subsequently, the bolting issues were addressed in generic issue B29. One of the issues deals specifically with high-strength bolting materials, which are vulnerable to stress corrosion cracking. A Westinghouse Owners Group funded program was established to develop in situ ultrasonic examination techniques to determine steam generator support bolting integrity at the head-to-shank and first-thread locations. This program was established in order to determine bolting integrity in place. Ultrasonic techniques were developed for both socket-head and flat-head bolt configurations. As a result of this program, in situ ultrasonic examination techniques were developed for examination of PWR steam generator support bolts. By employing these techniques utilities will be able to ensure the integrity of this in-place bolting without incurring the costs previously experienced during removal for surface examinations

  12. Stress evaluation of baffle former bolt for IASCC failure prediction

    International Nuclear Information System (INIS)

    Matsubara, T.; Tsutsui, T.; Kamei, Y.; Kitsu, M.

    2011-01-01

    Baffle structure in PWRs Reactor is quite important assembly for the core safety, and Baffle Former Bolts (BFBs) are fastener members for maintaining Baffle structure. It has been reported worldwide that some of BFBs were cracked due to IASCC (Irradiation Assisted Stress Corrosion Cracking) because BFBs are located at core region under severe environments, high neutron flux, high temperature and high stress. According to the material studies of IASCC on austenitic stainless steel, a crack initiation of IASCC is strongly related with the stress and the neutron fluence. For this reason, it is very important for IASCC failure prediction to simulate the stress of BFBs. However, the stress of BFBs are considered to be influenced by several factors and to be changed complexly as operational time increases, by irradiation creep of Bolt itself, swelling of Baffle structure, and so on. Therefore, it is difficult to estimate the stress histories of BFBs (Bolt stress as a function of operational time) precisely. Then, the author has developed the calculation method of the stress histories of BFBs considering irradiation effects (swelling and irradiation creep). In this method, the stress histories of BFBs are calculated by combining two kinds of FE models, Global model (modeled whole Baffle structure which consists of Baffle plates, Former plates and Core Barrel) and Local model (modeled around BFB finely). The whole Baffle structure deformation changes as a function of heat, swelling and irradiated creep are calculated by Global model, and the stress histories of BFBs are calculated by Local model using the outputs (deformations on driving nodes) of Global model. In the FE analysis of Local model, the stress of BFBs are calculated considering irradiation effects and elastic-plastic characteristics depending on neutron fluence, so this method enables to calculate precisely the stress of extreme small area of BFBs surface. This paper shows the outline of the calculation method

  13. Observation of martensitic structure evolution in Cu-Al-Ni single crystals with shape memory effect under external load using photoacoustic microscopy

    International Nuclear Information System (INIS)

    Muratikov, K.L.; Glazov, A.L.; Nikolaev, V.I.; Pul'nev, S.A.

    2006-01-01

    Photoacoustic microscopy is applied to observe the surface structure of Cu-Al-Ni shape-memory single crystals in both the loaded and unloaded states. Visualizing the early stages of the loading-induced martensitic transformation in Cu-Al-Ni single crystals is demonstrated to be feasible. The photoacoustic images are distinguished to advantage from the corresponding optical images by a higher contrast between different phases of the Cu-Al-Ni shape-memory alloy [ru

  14. Un mejor posicionamiento para un mejor Bolt : concurso Effie Colombia

    OpenAIRE

    Carvajal, Martin; Jaramillo, Isabella; Pedraza, Carlos; Rodriguez, Natalia; Amezquita, Juan José

    2017-01-01

    En este trabajo, se realiza una estrategia de marketing y comunicación para el proyecto Chevrolet en el mercado colombiano, teniendo en cuenta la información suministrada por la empresa y la investigación externa. El trabajo muestra 5 etapas diferentes: Desafío Estratégico, Perspectivas y Objetivos; Idea creativa; Medición de resultados; Viabilidad; y material gráfico. El objetivo de este trabajo es proponer una estrategia de marketing integral para la llegada del nuevo Chevrolet Bolt al merc...

  15. INVESTIGATION OF HYDROELASTIC BEHAVIOR OF A PONTOON-TYPE VLFS DURING UNSTEADY EXTERNAL LOADS IN WAVE CONDITION USING A HYBRID FINITE ELEMENT-BOUNDARY ELEMENT (FE-ME METHOD

    Directory of Open Access Journals (Sweden)

    Yong Cheng

    2017-01-01

    Full Text Available The hydroelastic behaviour of a pontoon-type VLFS subjected to unsteady external loads in wave condition is investigated in the context of the time-domain modal expansion theory, in which the boundary element method (BEM based on time domain Kelvin sources is used for hydrodynamic forces and the finite element method (FEM is adopted for solving the deflections of the VLFS. In this analysis, the interpolation-tabulation scheme is applied to assess rapidly and accurately the free-surface Green function in finite water depth, and the boundary integral equation of a quarter VLFS model is further established taking advantage of symmetry of flow field and structure. The VLFS is modelled as an equivalent solid plate based on the Mindlin plate theory. The coupled plate-water model is performed to determine the wave-induced responses and transient behaviour under external loads such as a huge mass impact onto the structure and moving loads of an airplane, respectively. These results are verified with existing numerical results and experimental test. Then, the developed numerical tools are used in the study of the combined action taking into account of the mass drop/airplane landing as well as forward or reverse incident wave action. The deflections of the runway, the time history of vertical positions and the trajectory of the airplane are also presented through a systematic time-domain simulation, which illustrates the usefulness of the presently developed numerical solutions.

  16. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-02-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  17. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-06-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  18. Laboratory evaluation of alloy X-750 clevis bolts removed from D.C. cook unit 1

    International Nuclear Information System (INIS)

    Hyres, J.; Xu, H.; Kalchik, K.; Thompson, G.

    2015-01-01

    This paper summarizes the results of the laboratory evaluation performed by Babcock and Wilcox on Alloy X-750 clevis bolts removed from the Lower Radial Support System (LRSS) at D.C. Cook Unit 1. A total of 29 clevis bolts - 16 broken and 13 intact - were provided for laboratory analysis and testing to document the extent of degradation, evaluate the integrity of the intact bolts, and identify the bolt degradation/failure mechanism(s). The laboratory work scope included visual and stereo-visual examinations of all bolts. Based on the results of these examinations, four bolts - two broken and two intact - were selected for more detailed analysis/testing, including Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), optical metallography, microhardness, chemical analysis by Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS), Rockwell hardness testing, and tensile testing. The laboratory data indicated the bolts failed by intergranular stress corrosion cracking (IGSCC). There was no evidence that the bolts failed due to fatigue cracking or mechanical overload. (authors)

  19. Enhancement of crack detection in stud bolts of nuclear reactor by ultrasonic technique

    International Nuclear Information System (INIS)

    Lee, Joon-Hyun; Choi, Sang-Woo; Oh, Won-Deok

    2004-01-01

    The stud bolt is one of crucial parts for safety of reactor vessels in nuclear power plants. Crack initiation and propagation were reported in stud bolts using closure of reactor vessel and head. Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure and radioactive leakage from nuclear reactor. In conventional ultrasonic testing for inspection of stud bolts, crack was detected by using shadow effect. It takes too much time to inspect stud bolt by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread. In this study, the signal processing technique for enhancing conventional ultrasonic technique and the advanced ultrasonic phased array technique were introduced for inspect stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. The phased array technique provides fast inspection and can be applied for structure of complex shape. There are sector scanning and linear scanning methods in phased array technique, and these scanning methods were applied to inspect stud bolt and detectability was investigated. (author)

  20. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2003-07-15

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The selected site and the field testing plan enabled us to test all three aspects of roof geological features. The development of the data interpretation methodologies and the geology mapping computer program have also been preceding well.

  1. Research on compliance coefficient calculation for heterogeneity material bolted joints of reactor internal

    International Nuclear Information System (INIS)

    Li Qing; Ren Xin; Zhang Kangda

    2009-01-01

    Using the finite element method, calculation and test are conducted on the bolted joints of four different diameters, and the existing calculation method for bolt compliance coefficient is analyzed. The results indicate that the calculated and test results by finite element method are agreed well, and value D/t f and β have a linear relation. (authors)

  2. Simulation and experiment for depth sizing of cracks in anchor bolts by ultrasonic phased array technology

    Science.gov (United States)

    Lin, Shan

    2018-04-01

    There have been lots of reports about the occurrence of cracks in bolts in aging nuclear and thermal power plants. Sizing of such cracks is crucial for assessing the integrity of bolts. Currently, hammering and visual tests are used to detect cracks in bolts. However, they are not applicable for sizing cracks. Although the tip diffraction method is well known as a crack sizing technique, reflection echoes from threads make it difficult to apply this technique to bolts. This paper addresses a method for depth sizing of cracks in bolts by means of ultrasonic phased array technology. Numerical results of wave propagation in bolts by the finite element method (FEM) shows that a peak associated within the vicinity of a crack tip can be observed in the curve of echo intensity versus refraction angle for deep cracks. The refraction angle with respect to this peak decreases as crack depth increases. Such numerical results are verified by experiments on bolt specimens that have electrical discharge machining notches or fatigue cracks with different depths. In the experiment, a 10-MHz linear array probe is used. Depth of cracks in bolts using the refraction angle associated with the peak is determined and compared to actual depths. The comparison shows that accurately determining a crack depth from the inspection results is possible.

  3. Non-destructive testing of full-length bonded rock bolts based on HHT signal analysis

    Science.gov (United States)

    Shi, Z. M.; Liu, L.; Peng, M.; Liu, C. C.; Tao, F. J.; Liu, C. S.

    2018-04-01

    Full-length bonded rock bolts are commonly used in mining, tunneling and slope engineering because of their simple design and resistance to corrosion. However, the length of a rock bolt and grouting quality do not often meet the required design standards in practice because of the concealment and complexity of bolt construction. Non-destructive testing is preferred when testing a rock bolt's quality because of the convenience, low cost and wide detection range. In this paper, a signal analysis method for the non-destructive sound wave testing of full-length bonded rock bolts is presented, which is based on the Hilbert-Huang transform (HHT). First, we introduce the HHT analysis method to calculate the bolt length and identify defect locations based on sound wave reflection test signals, which includes decomposing the test signal via empirical mode decomposition (EMD), selecting the intrinsic mode functions (IMF) using the Pearson Correlation Index (PCI) and calculating the instantaneous phase and frequency via the Hilbert transform (HT). Second, six model tests are conducted using different grouting defects and bolt protruding lengths to verify the effectiveness of the HHT analysis method. Lastly, the influence of the bolt protruding length on the test signal, identification of multiple reflections from defects, bolt end and protruding end, and mode mixing from EMD are discussed. The HHT analysis method can identify the bolt length and grouting defect locations from signals that contain noise at multiple reflected interfaces. The reflection from the long protruding end creates an irregular test signal with many frequency peaks on the spectrum. The reflections from defects barely change the original signal because they are low energy, which cannot be adequately resolved using existing methods. The HHT analysis method can identify reflections from the long protruding end of the bolt and multiple reflections from grouting defects based on mutations in the instantaneous

  4. Development of a Sealing-Bolt for the safeguarding of large containers such as multielement bottles

    International Nuclear Information System (INIS)

    D'Agraives, B.C.; Toornvliet

    1985-01-01

    A preliminary study on the development of a ''Sealing-Bolt'' is currently being carried out at JRC-Ispra. It is required for the safeguarding of large containers. A ''Sealing-Bolt'' would replace one - or more - of the conventional bolts, normally used for tightening a container's cover. It could not be removed - or unscrewed - without the knowledge of Inspectors. Thus, it has to meet the requirements of an Underwater Verifiable Seal and of a Threaded Stud-Bolt. It is proposed to derive the sealing feature from the VAK III seal, a LWR Fuel Assembly Ultrasonic Seal which has been developed by JRC-Ispra and is field tested at the Kahl Reactor Facility (FRG) since October 1983, while under evaluation for use by IAEA. The mechanical part asks for a specific study of a reliable system able to evidence that the bolt has been unscrewed during an opening of the lid

  5. Enhancement of crack detection in stud bolts of nuclear reactor by ultrasonic signal processing technique

    International Nuclear Information System (INIS)

    Lee, J.H.; Oh, W.D.; Choi, S.W.; Park, M.H.

    2004-01-01

    'Full-text:' The stud bolts is one of the most critical parts for safety of reactor vessels in the nuclear power plants. However, in the application of ultrasonic technique for crack detection in stud bolt, some difficulties encountered are classification of crack signal from the signals reflected from threads part in stud bolt. In this study, shadow effect technique combined with new signal processing method is Investigated to enhance the detectability of small crack initiated from root of thread in stud bolt. The key idea of signal processing is based on the fact that the shape of waveforms from the threads is uniform since the shape of the threads in a bolt is same. If some cracks exist in the thread, the flaw signals are different to the reference signals. It is demonstrated that the small flaws are efficiently detected by novel ultrasonic technique combined with this new signal processing concept. (author)

  6. Design and analysis of lid closure bolts for packages used to transport radioactive materials

    International Nuclear Information System (INIS)

    Raske, D.T.; Stojimirovic, A.

    1995-01-01

    The design criterion recommended by the U.S. Department of Energy for Category I radioactive packaging is found in Section III, Division 1, of the ASME Boiler and Pressure Vessel Code. This criterion provides material specifications and allowable stress limits for bolts used to secure lids of containment vessels. This paper describes the design requirements for Category I containment vessel lid closure bolts, and provides an example of a bolting stress analysis. The lid-closure bolting stress analysis compares calculations based on handbook formulas with an analysis performed with a finite-element computer code. The results show that the simple handbook calculations can be sufficiently accurate to evaluate the bolt stresses that occur in rotationally rigid lid flanges designed for metal-to-metal contact

  7. Wireless Impedance-Based SHM for Bolted Connections via Multiple PZT-Interfaces

    International Nuclear Information System (INIS)

    Nguyen, Khac Duy; Kim, Jeong Tae

    2011-01-01

    This study presents a structural health monitoring(SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model. Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint

  8. Expression of NO scavenging hemoglobin is involved in the timing of bolting in Arabidopsis thaliana

    DEFF Research Database (Denmark)

    Hebelstrup, Kim Henrik; Jensen, Erik Østergaard

    2008-01-01

    -symbiotic hemoglobin gene, GLB2, in Arabidopsis thaliana. Lines with GLB1 silencing had a significant delay of bolting and after bolting, shoots reverted to the rosette vegetative phase by formation of aerial rosettes at lateral meristems. Lines with overexpression of GLB1 or GLB2 bolted earlier than wild type plants....... By germinating the lines in a medium containing the nitric oxide (NO) donor, sodium nitroprusside (SNP), it was demonstrated that both GLB1 and GLB2 promote bolting by antagonizing the effect of NO, suggesting that non-symbiotic plant hemoglobin controls bolting by scavenging the floral transition signal...... molecule, NO. So far, NO scavenging has only been demonstrated for class 1 non-symbiotic hemoglobins. A direct assay in Arabidopsis leaf cells shows that GLB1 as well as the class 2 non-symbiotic hemoglobin, GLB2, scavenge NO in vivo. NO has also been demonstrated to be a growth stimulating signal...

  9. Remote controlled stud bolt handling device for reactor pressure vessel

    International Nuclear Information System (INIS)

    Shindo, Takenori; Shigehiro, Katsuya; Ito, Morio; Okada, Kenji

    1988-01-01

    In nuclear power stations, at the time of regular inspection, the works of opening and fixing the upper covers of reactor pressure vessels are carried out for inspecting the inside of reactor pressure vessels and exchanging fuel rods. These upper covers are fastened with many stud bolts, therefore, the works of opening and fixing require a large amount of labor, and are done under the restricted condition of wearing protective clothings and masks. Babcock Hitachi K.K. has completed the development of a remotely controlled automatic bolt tightenig device for this purpose, therefore, its outline is reported. The conventional method of these works and the problems in it are described. The design of the new device aimed at the parallel execution of cleaning screw threads, loosening and tightening nuts, and taking off and putting on nuts and washers, thus contributing to the shortening of regular inspection period, the reduction of the radiation exposure of workers, and the decrease of the number of workers. The function, reliability and endurance of the new device were confirmed by the verifying test using a device made for trial. The device is composed of a stand, a rail and four stations each with a cleaning unit, a stud tensioner and a nut handling unit. (K.I.)

  10. Self-healing bolted joint employing a shape memory actuator

    Science.gov (United States)

    Muntges, Daniel E.; Park, Gyuhae; Inman, Daniel J.

    2001-08-01

    This paper is a report of an initial investigation into the active control of preload in the joint using a shape memory actuator around the axis of the bolt shaft. Specifically, the actuator is a cylindrical Nitinol washer that expands axially when heated, according to the shape memory effect. The washer is actuated in response to an artificial decrease in torque. Upon actuation, the stress generated by its axial strain compresses the bolted members and creates a frictional force that has the effect of generating a preload and restoring lost torque. In addition to torque wrenches, the system in question was monitored in all stages of testing using piezoelectric impedance analysis. Impedance analysis drew upon research techniques developed at Center for Intelligent Material Systems and Structures, in which phase changes in the impedance of a self-sensing piezoceramic actuator correspond to changes in joint stiffness. Through experimentation, we have documented a successful actuation of the shape memory element. Due to complexity of constitutive modeling, qualitative analysis by the impedance method is used to illustrate the success. Additional considerations encountered in this initial investigation are made to guide further thorough research required for the successful commercial application of this promising technique.

  11. Evaluating external nutrient and suspended-sediment loads to Upper Klamath Lake, Oregon, using surrogate regressions with real-time turbidity and acoustic backscatter data

    Science.gov (United States)

    Schenk, Liam N.; Anderson, Chauncey W.; Diaz, Paul; Stewart, Marc A.

    2016-12-22

    Executive SummarySuspended-sediment and total phosphorus loads were computed for two sites in the Upper Klamath Basin on the Wood and Williamson Rivers, the two main tributaries to Upper Klamath Lake. High temporal resolution turbidity and acoustic backscatter data were used to develop surrogate regression models to compute instantaneous concentrations and loads on these rivers. Regression models for the Williamson River site showed strong correlations of turbidity with total phosphorus and suspended-sediment concentrations (adjusted coefficients of determination [Adj R2]=0.73 and 0.95, respectively). Regression models for the Wood River site had relatively poor, although statistically significant, relations of turbidity with total phosphorus, and turbidity and acoustic backscatter with suspended sediment concentration, with high prediction uncertainty. Total phosphorus loads for the partial 2014 water year (excluding October and November 2013) were 39 and 28 metric tons for the Williamson and Wood Rivers, respectively. These values are within the low range of phosphorus loads computed for these rivers from prior studies using water-quality data collected by the Klamath Tribes. The 2014 partial year total phosphorus loads on the Williamson and Wood Rivers are assumed to be biased low because of the absence of data from the first 2 months of water year 2014, and the drought conditions that were prevalent during that water year. Therefore, total phosphorus and suspended-sediment loads in this report should be considered as representative of a low-water year for the two study sites. Comparing loads from the Williamson and Wood River monitoring sites for November 2013–September 2014 shows that the Williamson and Sprague Rivers combined, as measured at the Williamson River site, contributed substantially more suspended sediment to Upper Klamath Lake than the Wood River, with 4,360 and 1,450 metric tons measured, respectively.Surrogate techniques have proven useful at

  12. Structural health monitoring for bolt loosening via a non-invasive vibro-haptics human-machine cooperative interface

    Science.gov (United States)

    Pekedis, Mahmut; Mascerañas, David; Turan, Gursoy; Ercan, Emre; Farrar, Charles R.; Yildiz, Hasan

    2015-08-01

    For the last two decades, developments in damage detection algorithms have greatly increased the potential for autonomous decisions about structural health. However, we are still struggling to build autonomous tools that can match the ability of a human to detect and localize the quantity of damage in structures. Therefore, there is a growing interest in merging the computational and cognitive concepts to improve the solution of structural health monitoring (SHM). The main object of this research is to apply the human-machine cooperative approach on a tower structure to detect damage. The cooperation approach includes haptic tools to create an appropriate collaboration between SHM sensor networks, statistical compression techniques and humans. Damage simulation in the structure is conducted by releasing some of the bolt loads. Accelerometers are bonded to various locations of the tower members to acquire the dynamic response of the structure. The obtained accelerometer results are encoded in three different ways to represent them as a haptic stimulus for the human subjects. Then, the participants are subjected to each of these stimuli to detect the bolt loosened damage in the tower. Results obtained from the human-machine cooperation demonstrate that the human subjects were able to recognize the damage with an accuracy of 88 ± 20.21% and response time of 5.87 ± 2.33 s. As a result, it is concluded that the currently developed human-machine cooperation SHM may provide a useful framework to interact with abstract entities such as data from a sensor network.

  13. The Influence on Modal Parameters of Thin Cylindrical Shell under Bolt Looseness Boundary

    Directory of Open Access Journals (Sweden)

    Hui Li

    2016-01-01

    Full Text Available The influence on modal parameters of thin cylindrical shell (TCS under bolt looseness boundary is investigated. Firstly, bolt looseness boundary of the shell is divided into two types, that is, different bolt looseness numbers and different bolt looseness levels, and natural frequencies and mode shapes are calculated by finite element method to roughly master vibration characteristics of TCS under these conditions. Then, the following measurements and identification techniques are used to get precise frequency, damping, and shape results; for example, noncontact laser Doppler vibrometer and vibration shaker with excitation level being precisely controlled are used in the test system; “preexperiment” is adopted to determine the required tightening torque and verify fixed constraint boundary; the small-segment FFT processing technique is employed to accurately measure nature frequency and laser rotating scanning technique is used to get shape results with high efficiency. Finally, based on the measured results obtained by the above techniques, the influence on modal parameters of TCS under two types of bolt looseness boundaries is analyzed and discussed. It can be found that bolt looseness boundary can significantly affect frequency and damping results which might be caused by changes of nonlinear stiffness and damping and in bolt looseness positions.

  14. Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Suh, D. M.; Park, M. H.; Hong, S. S.

    1989-01-01

    Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking. Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture. Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced

  15. Application of shape memory alloys in bolted flanged connections

    International Nuclear Information System (INIS)

    Zhu Shichun; Lu Xiaofeng

    2009-01-01

    The Shape Memory Effect (SME) and super elasticity of the Shape Memory Alloys (SMA) can make up the clamping force decreasing caused by the creep and relaxation behavior in Bolted Flanged Connections (BFC), and improve the reliability of the BFC. Advances in the research of SMA in BFC home and abroad is summarized in this paper. The application prospects of Ti-Ni-Pd, Ti-Ni-Hf, Fe-Mn-Si, Cu-Al-Ni and Ni-Al-Mn in the BFC are also discussed. It is considered that the compressive characteristics of the parent phase of SMA should be studied further for the application of SMA to BFC besides the design of sealing structure. When more basic research data is accumulated, BFC with high sealing performance for the critical engineering applications can be developed based on the comprehensive consideration of the stability and reliability of the clamping force. (authors)

  16. Visual Inspection of the Flow Distribution Plate Bolts of a Nuclear Steam Generator

    International Nuclear Information System (INIS)

    Jeong, Woo Tae; Kim, Suk Tae; Sohn, Wook; Kang, Duk Won; Kang, Seok Chul

    2007-01-01

    To develop a system for visually inspecting the flow distribution plate (FDP) bolts of a nuclear steam generator, we reviewed several types of similar inspection equipment. The equipment which are currently available are mostly for inspecting lower part of a steam generator such as tube sheets and annulus except ELVS (Eggcrate Visual Inspection System). However, the design concept of ELVS could not be used for developing a device which enables the visual inspection of flow distribution plate bolts. Therefore, based on the current state of the art technology on the similar equipment, we conceptually designed a new inspection system for checking the FDP bolts

  17. Prevention of bolting degradation or failure in pressure boundary and support applications

    International Nuclear Information System (INIS)

    Merrick, E.A.; Rivers, A.; Bickford, J.; Marston, T.U.

    1986-01-01

    A discussion is presented of bolting degradation or failure experience in pressure boundary and component support applications in US commercial nuclear plants and the industry program to prevent failures in the future. The focus turns to steps which plant owners can take today to guard against pressure boundary bolt failure or degradation for existing plants or units being constructed. 'Tools' or products which the plant owner can expect from current industry programs which will be available in the near future to aid in understanding and improving bolting practices are described. (author)

  18. Optimized bolt tightening strategies for gasketed flanged pipe joints of different sizes

    International Nuclear Information System (INIS)

    Abid, Muhammad; Khan, Ayesha; Nash, David Hugh; Hussain, Masroor; Wajid, Hafiz Abdul

    2016-01-01

    Achieving a proper preload in the bolts of a gasketed bolted flanged pipe joint during joint assembly is considered important for its optimized performance. This paper presents results of detailed non-linear finite element analysis of an optimized bolt tightening strategy of different joint sizes for achieving proper preload close to the target stress values. Industrial guidelines are considered for applying recommended target stress values with TCM (torque control method) and SCM (stretch control method) using a customized optimization algorithm. Different joint components performance is observed and discussed in detail.

  19. Bolt-Grout Interactions in Elastoplastic Rock Mass Using Coupled FEM-FDM Techniques

    Directory of Open Access Journals (Sweden)

    Debasis Deb

    2010-01-01

    Full Text Available Numerical procedure based on finite element method (FEM and finite difference method (FDM for the analysis of bolt-grout interactions are introduced in this paper. The finite element procedure incorporates elasto-plastic concepts with Hoek and Brown yield criterion and has been applied for rock mass. Bolt-grout interactions are evaluated based on finite difference method and are embedded in the elasto-plastic procedures of FEM. The experimental validation of the proposed FEM-FDM procedures and numerical examples of a bolted tunnel are provided to demonstrate the efficacy of the proposed method for practical applications.

  20. Upgrading of existing NPPs with 440 and 1000 MW WWER type pressurized water reactors for severe external loading conditions. Proceedings. Working material. V. 1, 2

    Energy Technology Data Exchange (ETDEWEB)

    Godoy, A; Gurpinar, A [eds.; International Atomic Energy Agency, Division of Nuclear Installation Safety, Vienna (Austria)

    1993-07-01

    The Seminar was intended to provide the opportunity for the exchange of updated information concerning the state-of-the-art related to structural safety of the WWER 440 and 1000 MW nuclear power plants operating or under construction in the Russian Federation and several Eastern European countries. Codes and standards, design assumptions, seismic upgrading and requalification activities, recent verification by experimental methods as well as the corresponding reanalysis and reevaluation procedures were included in the scope. Also presented and discussed were the results of recent studies of typical structures and components under seismic loading. The Seminar was divided into five working sessions. Each session consisted of several presentations by invited speakers and extensive discussions. The topic of discussions involved the following: standards used during design phase, input load definitions and criteria, evaluation of as-built conditions and walk down information, site-specific dynamic response of structures based on recent studies and evaluation of results, capacity evaluations of components and systems based on updated acceptance criteria and strengthening concepts, functional qualification of active mechanical and electrical components and systems.

  1. Upgrading of existing NPPs with 440 and 1000 MW WWER type pressurized water reactors for severe external loading conditions. Proceedings. Working material. V. 1, 2

    International Nuclear Information System (INIS)

    Godoy, A.; Gurpinar, A.

    1993-01-01

    The Seminar was intended to provide the opportunity for the exchange of updated information concerning the state-of-the-art related to structural safety of the WWER 440 and 1000 MW nuclear power plants operating or under construction in the Russian Federation and several Eastern European countries. Codes and standards, design assumptions, seismic upgrading and requalification activities, recent verification by experimental methods as well as the corresponding reanalysis and reevaluation procedures were included in the scope. Also presented and discussed were the results of recent studies of typical structures and components under seismic loading. The Seminar was divided into five working sessions. Each session consisted of several presentations by invited speakers and extensive discussions. The topic of discussions involved the following: standards used during design phase, input load definitions and criteria, evaluation of as-built conditions and walk down information, site-specific dynamic response of structures based on recent studies and evaluation of results, capacity evaluations of components and systems based on updated acceptance criteria and strengthening concepts, functional qualification of active mechanical and electrical components and systems

  2. Reversible fastener clamp load monitor with continuous visual or remote readout

    Science.gov (United States)

    Hodge, Malcolm H.; Kausel, Theodore C., Jr.; Begley, Matthew R.

    1998-03-01

    SIMS has developed a simple means for detecting and monitoring both absolute and relative clamp load, or bolt tension, in fastener systems. More than twenty-five percent of automotive failures are known to be due to undetected loss of fastener clamp load. While the equivalent aerospace maintenance statistics are not known, the average automobile has 3,500 fasteners while a Boeing 747 has closer to one million. It is therefore anticipated that the new SensaBolt clamp load tracking system could find wide applications in the aerospace arena. We describe a visually-evident and retrofitted clamp load monitoring design which is based on the differential joint substrate compression at, and immediately adjacent to, the fastener location. This intrinsically-accurate indicator does not necessarily require alteration in either the bolt or nut geometries, thereby facilitating product introduction and retrofit in aging aircraft applications. In addition, SensaBolt's sole reliance on substrate compression renders it more accurate then torque wrench or turn-of-nut techniques. Readout may be accomplished by any of three principal methods: for those applications with ease of access to the sensor, loss of tension can be determined by direct visual inspection. Application of a standard wrench can then be made to restore the fastener's proper tightness, per the SensaBolt indicators. In those instances where line-of-sight is unimpeded and more formal inspection is desired, the SensaBolt may be interrogated by a laser scanner bar code reader. Finally, SensaBolt may be addressed by the SIMS fiber optic harness for those instances where full-time remote interrogation is desired.

  3. Preliminary aseismic analysis on bolts of driving mechanism in absorption sphere shutdown system

    International Nuclear Information System (INIS)

    Chen Feng; Li Tianjin; Zhang Zhengming; Huang Zhiyong; Bo Hanliang

    2012-01-01

    The absorption sphere shutdown system performs an important role in reactivity regulating and control. Driving mechanism is a set of key mechanical moving parts which is used to control falling of absorption spheres in absorption sphere shutdown system. It is about 5 m for driving mechanism with the slim structure, which is connected with the upper supported plate of metal reactor internals through storage vessel with bolts. Both the storage vessel and driving mechanism are equipment of seismic classification I. It is significant to calculate and check the bolts strength of driving mechanism. In this paper, complicate structure of driving mechanism was simplified to three variable cross sections and statically indeterminate problem was solved. The bolts at the bottom and on the top of the storage vessel were calculated and checked. The preliminary results indicate that the bolts strength is reliable and safe, and the supporting force at the most weak point of driving mechanism is as well obtained. (authors)

  4. Corrosion failure of a bolt made of the 25Kh1MF material

    International Nuclear Information System (INIS)

    Liska, V.; Cechova, D.; Velkoborsky, J.

    1989-01-01

    M36x4 bolts, of which there are 222 at each nuclear power plant unit, are made of the 25Kh1MF or 38KhN3MFA steel. They are located in an environment with elevated temperature, with damp air and with boric acid. Corrosion of these bolts is due to the rather poor metallurgical quality of the steel. No inadmissible inhomogeneities of the type of lines of inclusions occur in the bolt material produced by cold rolling but defects of the type of laps were found on the threads. It is suggested that if the cold rolling technology were obviated, corrosion failure of the bolts might not occur. (M.D.). 7 figs., 3 refs

  5. Ultrasonic extensometry for determining bolt preload in heavy industry - from petrochemical to reactors

    International Nuclear Information System (INIS)

    Erdman, D.C.

    1981-01-01

    Use of ultrasonic extensometers has found wide application for bolt preload determination in airborne and aerospace applications where elongation measurement accuracy is often required to .0001 in. Experience has now been gained in heavy industry with fasteners up to 12 feet long, often on studs and bolts with relatively rough head surfaces. Here, accuracy may be reduced to .001 inch, a figure far better than available from torque wrenches. This paper describes some of these heavy industry applications

  6. The Guidelines for Modelling the Preloading Bolts in the Structural Connection Using Finite Element Methods

    OpenAIRE

    Paulina Krolo; Davor Grandić; Mladen Bulić

    2016-01-01

    The aim of this paper is the development of the two different numerical techniques for the preloading of bolts by the finite element method using the software Abaqus Standard. Furthermore, this paper gave detailed guidelines for modelling contact, method for solving the numerical error problems such as numerical singularity error and negative eigenvalues due to rigid body motion or the problem of the extensive elongation of bolts after pretension which is occurring during the analysis. The be...

  7. Analysis of anchor bolt belongs to fan in nuclear power plant

    International Nuclear Information System (INIS)

    Miao Xueliang; Luan Xingfeng; Zhang Wei; Bian Chunhua; Yu Xiaoyan; Xu Ke; Liu Hongqun

    2014-01-01

    Through on the fan anchor bolt material components, metallurgical structure and fracture analysis indicates that: material composition and microscopic are abnormal, it led to material brittle increased, the fracture is rock-candy structure, the last part is toughness structure. The reason is the the fan vibrate oversize. At last, we put forward some measures. Just like, control the vibration of the fan, set a nominal tightening torque when installing bolt. (authors)

  8. Health monitoring of 90° bolted joints using fuzzy pattern recognition of ultrasonic signals

    International Nuclear Information System (INIS)

    Jalalpour, M; El-Osery, A I; Austin, E M; Reda Taha, M M

    2014-01-01

    Bolted joints are important parts for aerospace structures. However, there is a significant risk associated with assembling bolted joints due to potential human error during the assembly process. Such errors are expensive to find and correct if exposed during environmental testing, yet checking the integrity of individual fasteners after assembly would be a time consuming task. Recent advances in structural health monitoring (SHM) can provide techniques to not only automate this process but also make it reliable. This integrity monitoring requires damage features to be related to physical conditions representing the structural integrity of bolted joints. In this paper an SHM technique using ultrasonic signals and fuzzy pattern recognition to monitor the integrity of 90° bolted joints in aerospace structures is described. The proposed technique is based on normalized fast Fourier transform (NFFT) of transmitted signals and fuzzy pattern recognition. Moreover, experimental observations of a case study on an aluminum 90° bolted joint are presented. We demonstrate the ability of the proposed method to efficiently monitor and indicate bolted joint integrity. (paper)

  9. An investigation into the anti-releasing performance of a serrated bolt

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jin Hwan; Lee, Hyun Kyu; Park, Ke Un; Kim, Jong Bong [Seoul Natinal University, Seoul (Korea, Republic of)

    2015-11-15

    As the sizes of electric products, such as mobile phones and watch phones, decrease, the joining bolt for the electric product should also be miniaturized. However, the miniature-sized bolt has to support sufficient joining torque and joining force. The bolt also has to support sufficient anti-releasing torque to keep the product fastened. We investigated a serrated bolt as a candidate for a miniature-sized fastener to increase the anti-release torque. In the serrated bolt, serration shapes are formed on the bottom surface of a bolt head to create an obstacle to releasing. In this study, finite element analyses were carried out on joining and releasing, and the anti-release torque was predicted. Through the joining and releasing analyses for various values of the elastic modulus and yield strength of the joined part, the effect of the mechanical properties of the joined part on the anti-releasing performance were investigated. The analysis results showed that a high strength insert nut is needed to increase the anti-releasing torque when the yield strength of the joined part is low, such as a plastic board in a mobile phone.

  10. Effective degradation of rhodamine B by electro-Fenton process, using ferromagnetic nanoparticles loaded on modified graphite felt electrode as reusable catalyst: in neutral pH condition and without external aeration.

    Science.gov (United States)

    Tian, Jiangnan; Zhao, Jixiang; Olajuyin, Ayobami Matthew; Sharshar, Moustafa Mohamed; Mu, Tingzhen; Yang, Maohua; Xing, Jianmin

    2016-08-01

    Polytetrafluoroethylene/ferromagnetic nanoparticle/carbon black (PTFE/MNP/CB)-modified graphite felt (GF) was successfully applied as cathode for the mineralization of rhodamine B (RhB) in electro-Fenton (EF) process. The modified cathode showed high decolorization efficiency for RhB solution even in neutral pH condition and without external aeration, achieving nearly complete decolorization and 89.52 % total organic carbon (TOC) removal after 270-min oxidation with the MNP load 1.2 g at 50 A/m(2). Moreover, the operational parameters (current density, MNP load, initial pH, and airflow rate) were optimized. After that, adsorption isotherm was also conducted to compare the absorption quantity of CB and carbon nanotube (CNT). Then, the surface morphologies of MNPs were characterized by transmission electron microscope (TEM), energy-dispersive X-ray detector (EDX), and Fourier transform infrared spectroscopy (FTIR); and the modified cathode was characterized by SEM and contact angle. Finally, the stability and reusability of modified cathode were tested. Result uncovered that the PTFE/MNP/CB-modified cathode has the potential for industrial application and the solution after treatment was easily biodegradable.

  11. [Analysis of the results of the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology for HIV-1, HCV, and HBV viral loads].

    Science.gov (United States)

    Orta Mira, Nieves; Serrano, María del Remedio Guna; Martínez, José-Carlos Latorre; Ovies, María Rosario; Poveda, Marta; de Gopegui, Enrique Ruiz; Cardona, Concepción Gimeno

    2011-12-01

    Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most important markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarized the results obtained in the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology for HIV-1, HCV, and HBV viral loads and HCV genotyping. In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 3-5 log(10) copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (22.6% on average) obtained values out of the accepted range (mean ± 0.2 log(10)copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (Δ<0.5 log(10)copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 86.1% in the case of HCV and 87.1% in HBV, obtained all the results within the accepted range (mean ± 1.96 SD log(10)UI/mL). Post-analytical errors due to mistranscription of the results were detected in these controls. Data from this analysis reinforce the utility of proficiency programs to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase in overall quality. Due to interlaboratory variability, use of the same method and the same laboratory for patient follow-up is advisable. Copyright © 2011 Elsevier España S.L. All rights reserved.

  12. Theoretical Calculation and Analysis on the Composite Rock-Bolt Bearing Structure in Burst-Prone Ground

    OpenAIRE

    Cheng, Liang; Zhang, Yidong; Ji, Ming; Cui, Mantang; Zhang, Kai; Zhang, Minglei

    2015-01-01

    Given the increase in mining depth and intensity, tunnel failure as a result of rock burst has become an important issue in the field of mining engineering in China. Based on the Composite Rock-Bolt Bearing Structure, which is formed due to the interaction of the bolts driven into the surrounding rock, this paper analyzes a rock burst prevention mechanism, establishes a mechanical model in burst-prone ground, deduces the strength calculation formula of the Composite Rock-Bolt Bearing Structur...

  13. The effect of cultivar, sowing date and transplant location in field on bolting of Welsh onion (Allium fistulosum L.).

    Science.gov (United States)

    Dong, Yinxin; Cheng, Zhihui; Meng, Huanwen; Liu, Hanqiang; Wu, Cuinan; Khan, Abdul Rehman

    2013-10-07

    Bolting reduces the quality and commercial yield of Welsh onion (Allium fistulosum L.) in production. However, seed production is directly dependent on flower induction and bolting. The Welsh onion belongs to the green plant vernalisation type, specific seedling characteristics and sufficient accumulated time at low temperature are indispensible for the completion of its vernalisation process. Only if these conditions for vernalisation are fulfilled, the plants will bolt in the following year. The present investigation evaluated the effects of cultivar, sowing date and transplant location in field on the bolting of Welsh onion at the Horticultural Farm of the College of Horticulture, Northwest A&F University, Yangling, Shannxi Province, China in two succeeding production years: 2010-2011 and 2011-2012. A strip split plot layout within a randomised complete block design with three replications was used. The results revealed that all three factors (cultivar, sowing date and transplant location) and their interaction had significant effects on the initiation and final rate of bolting observed by 30 April. The earliest bolting date (14 February, 2011 and 15 February, 2012) and the highest bolting rate (100% in 2011 and 62% in 2012) occurred when the JinGuan cultivar was sown on 20 August and transplanted in a plastic tunnel, whereas the latest date and lowest rate (no bolting observed until 30 April) of bolting occurred when the XiaHei cultivar was sown on 29 September and transplanted in an open field. These results suggest that we can control bolting in Welsh onion production by choosing an appropriate cultivar, sowing date and transplant location. Choosing a late bolting cultivar, such as cultivar XiaHei, sowing around October, and transplanting in the open field can significantly delay bolting, while a sowing date in late August should be selected for seed production, and the seedlings should be transplanted in a plastic tunnel to accelerate development of the

  14. Efeitos do peso externo nos chutes espontâneos de lactentes nos primeiros dois meses de vida Effects of external load on spontaneous kicking by one and two-month-old infants

    Directory of Open Access Journals (Sweden)

    JF Landgraf

    2008-12-01

    Full Text Available OBJETIVO: Caracterizar o padrão de chutes espontâneos de lactentes nas idades de um e dois meses, bem como verificar se o peso externo modifica o padrão dos chutes nessas idades. MÉTODOS: Oito lactentes foram filmados nas idades de um e dois meses, estando em supino em uma cadeira infantil reclinada a 0º, na qual havia um móbile na extremidade superior e um painel na extremidade inferior. O experimento teve a duração de seis minutos e 20 segundos, durante os quais foram observados os movimentos de chutes nas situações sem e com peso de 1/10 e 1/3 da massa do membro inferior do lactente. Os pesos externos foram adicionados nos tornozelos do lactente. Pela análise das imagens coletadas por filmadoras digitais, foram verificados a freqüência de chutes e de contatos dos pés em um painel, os movimentos uni e bipodais, a preferência podal e o padrão de coordenação intramembro. RESULTADOS: O teste qui-quadrado revelou aumento significativo da freqüência de chutes nas idades de dois meses e nas situações de peso de 1/10 e pós-peso. Na situação de peso de 1/3 da massa do membro, verificaram-se diminuição do contato dos pés no painel e, na idade de dois meses, aumento da freqüência de contatos. Em todas as situações e idades, houve predomínio por chutes unipodais, não havendo preferência por um dos membros. Além disso, o padrão de coordenação intramembro dos chutes foi caracterizado como em-fase em ambas as idades. CONCLUSÕES: Fatores intrínsecos como a idade e extrínsecos como o peso externo referente a 1/10 da massa do membro inferior promoveram o aumento da freqüência dos chutes espontâneos em lactentes nas idades de um e dois meses.OBJECTIVE: To characterize the spontaneous kicking patterns among one and two-month-old infants, and find whether an external load can modify such patterns at this age. METHODS: Eight infants were filmed at the ages of one and two months, while in the supine position in a baby

  15. Modification of ASTM Standard E1681 on Environmental Cracking to Include Bolt-Load Specimen Testing

    National Research Council Canada - National Science Library

    Underwood, Jean D. M

    1997-01-01

    Benet Laboratories experience with environmental cracking of cannon components has been combined with the technical expertise of various participants at ASTM technical meetings and symposia to develop...

  16. Evaluation of the clamping force in high tension bolt by using the ultrasonic nonlinearity

    International Nuclear Information System (INIS)

    Jang, Kyung Young; Cheon, Hae Wha; Ha, Hob; Park, Man Sick; Kim, No You

    2005-01-01

    High tension bolts have been used widely for the clamping of many kinds of large structure. Therefore, its estimation has been regarded as main issue in the maintenance of high tension bolts. This paper proposes a novel method using the ultrasonic nonlinearity, which is based on the dependency of sound speed on the stress. For this we introduce nonlinear elastic constants in the stress-strain relationship, and derive the sound speed as a linear function of stress. In order to verify the usefulness of the proposed method, two kinds of experiments are carried out: The first one is to measure the sound speed when the bolt is stressed by the tension tester. The result showed good agreement with the expected linear relationship between the sound speed and the axial stress. The second one is to measure the sound speed when the bolt is stressed by the torque wrench. The results showed that the sound speed was decreased when the torque was increased. From these results we can say that the proposed method is enough useful to evaluate the clamping force in the high tension bolt.

  17. Numerical Study on Ultimate Behaviour of Bolted End-Plate Steel Connections

    Directory of Open Access Journals (Sweden)

    R.E.S. Ismail

    Full Text Available Abstract Bolted end-plate steel connections have become more popular due to ease of fabrication. This paper presents a three dimension Finite Element Model (FEM, using the multi-purpose software ABAQUS, to study the effect of different geometrical parameters on the ultimate behavior of the connection. The proposed model takes into account material and geometrical non-linearities, initial imperfection, contact between adjacent surfaces and the pretension force in the bolts. The Finite Element results are calibrated with published experimental results ''briefly reviewed in this paper'' and verified that the numerical model can simulate and analyze the overall and detailed behavior of different types of bolted end-plate steel connections. Using verified FEM, parametric study is then carried out to study the ultimate behavior with variations in: bolt diameter, end-plate thickness, length of column stiffener, angle of rib stiffener. The results are examined with respect to the failure modes, the evolution of the resistance, the initial stiffness, and the rotation capacity. Finally, the ultimate behavior of the bolted end-plate steel connection is discussed in detail, and recommendations for the design purpose are made.

  18. Nonlinear Modeling and Identification of an Aluminum Honeycomb Panel with Multiple Bolts

    Directory of Open Access Journals (Sweden)

    Yongpeng Chu

    2016-01-01

    Full Text Available This paper focuses on the nonlinear dynamics modeling and parameter identification of an Aluminum Honeycomb Panel (AHP with multiple bolted joints. Finite element method using eight-node solid elements is exploited to model the panel and the bolted connection interface as a homogeneous, isotropic plate and as a thin layer of nonlinear elastic-plastic material, respectively. The material properties of a thin layer are defined by a bilinear elastic plastic model, which can describe the energy dissipation and softening phenomena in the bolted joints under nonlinear states. Experimental tests at low and high excitation levels are performed to reveal the dynamic characteristics of the bolted structure. In particular, the linear material parameters of the panel are identified via experimental tests at low excitation levels, whereas the nonlinear material parameters of the thin layer are updated by using the genetic algorithm to minimize the residual error between the measured and the simulation data at a high excitation level. It is demonstrated by comparing the frequency responses of the updated FEM and the experimental system that the thin layer of bilinear elastic-plastic material is very effective for modeling the nonlinear joint interface of the assembled structure with multiple bolts.

  19. PIXE Analysis of Metal Hull Bolts From HMB DeBraak

    International Nuclear Information System (INIS)

    Correll, Francis D.; Cole, Lord K.; Slater, Charles J.; Vanhoy, Jeffrey R.; Fithian, Charles H.

    2009-01-01

    HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.

  20. PIXE Analysis of Metal Hull Bolts From HMB DeBraak

    Science.gov (United States)

    Correll, Francis D.; Cole, Lord K.; Slater, Charles J.; Vanhoy, Jeffrey R.; Fithian, Charles H.

    2009-03-01

    HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.

  1. Simulation and design of ECT differential bobbin probes for the inspection of cracks in bolts

    International Nuclear Information System (INIS)

    Ra, S W; Im, K H; Woo, Y D; Lee, S G; Kim, H J; Song, S J; Kim, S K; Cho, Y T; Jung, J A

    2015-01-01

    All Various defects could be generated in bolts for a use of oil filters for the manufacturing process and then may affect to the safety and quality in bolts. Also, fine defects may be imbedded in oil filter system during multiple forging manufacturing processes. So it is very important that such defects be investigated and screened during the multiple manufacturing processes. Therefore, in order effectively to evaluate the fine defects, the design parameters for bobbin-types were selected under a finite element method (FEM) simulations and Eddy current testing (ECT). Especially the FEM simulations were performed to make characterization in the crack detection of the bolts and the parameters such as number of turns of the coil, the coil size and applied frequency were calculated based on the simulation results. (paper)

  2. Investigation of corrosion and stress corrosion cracking in bolting materials on light water reactors

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1986-01-01

    Laboratory experiments performed at Brookhaven National Laboratory have shown that the concentration of boric acid to a moist paste at approximately the boiling point of water can produce corrosion rates of the order of approximately 3.5mm per year on bolting and piping materials, which values are consistent with service experience. Other failure evaluation experience has shown that primary coolant-lubricant interaction may lead to stress corrosion cracking (SCC) of steam generator manway studs. An investigation was also performed on eleven lubricants and their effects on A193 B7 and A540 B24 bolting materials. H 2 S generation by the lubricants, coefficient of friction results and transgranular SCC of the bolting materials in steam are discussed. (author)

  3. Experimental verification of lifetime of bolting joints for WWER reactor pressure vessels

    International Nuclear Information System (INIS)

    Brumovsky, M.; Polachova, H.

    1992-01-01

    This paper presents results from experimental verification of cyclic lifetime of bolting joints of M 140x6 mm type used for WWER-440 MW reactor pressure vessels. Bolting joints or real dimensions were tested in a special testing equipment ZS 1000 in Skoda Concern. Stud bolts are made from 25Kh1MF or 38KhN3MFA type of steels. Tests were carried out at operating as well as at room temperatures with coefficient of asymmetry equal to 0.1; one tests was realized with given bending moment. Experimental results have been compared with calculated lifetimes according to ASME, Soviet and CMEA Codes. In all cases calculations give conservative assessments. (orig.)

  4. Special remote tooling developed and utilized to tighten TFTR TF coil casing bolts

    International Nuclear Information System (INIS)

    Burgess, T.W.; Walton, G.R.; Meighan, T.G.; Paul, B.L.

    1993-01-01

    Special tooling has been developed and used to tighten toroidal field (TF) coil casing bolts that have loosened from years of Tokamak Fusion Test Reactor (TFTR) operation. Due to their location, many of the TF casing bolts cannot be directly accessed or viewed; their condition was first discovered during unrelated inspections in 1988. Engineering solutions were, sought until 1992, when a remotely operated wrench concept was successfully demonstrated on a TF coil mockup. The concept was developed into several working tools that have successfully been applied to tighten several thousand TF casing bolts during recent scheduled outages. This effort has improved the integrity and reliability of the TF coil system in preparing for the final experimental phase of the TFTR. This paper discusses the design and application of this tooling

  5. Single-impact calibrated electromagnetic tightening of long-life bolted joints in aviation structures

    Science.gov (United States)

    Firsov, V. A.; Bekhmet'ev, V. I.

    The general design and operation of a newly developed electromagnetic impact driver for the assembly of aviation structures is described. The electromagnetic impact driver makes it possible to considerably improve the precision of bolt torquing during the assembly. To test the performance of the new tool, M6 bolts of 16KhSN steel (tensile strength 120 +/- 10 kg/sq mm) were tightened by a manual torque wrench and by the electromagnetic impact driver. It is shown that the scatter of bolt elongation during the tightening by the impact driver is a factor of 3-5 less than in the case of manual torquing, which corresponds to a torque precision of 1.5-2 percent.

  6. Investigation of corrosion and stress corrosion cracking in bolting materials on light water reactors

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1985-01-01

    Laboratory experiments performed at BNL have shown that the concentration of boric acid to a moist paste at approximately the boiling point of water can produce corrosion rates of the order of several tenths of an inch per year on bolting and piping materials, which values are consistent with service experience. Other failure evaluation experience has shown that primary coolant/lubricant interaction may lead to stress corrosion cracking (SCC) of steam generator manway studs. An investigation was also performed on eleven lubricants and their effects on A193 B7 and A540 B24 bolting materials. H 2 S generation by the lubricants, coefficient of friction results and transgranular SCC of the bolting materials in steam are discussed. 13 refs

  7. An analysis of bolted opening structure and development of analysis expert system using ANSYS

    International Nuclear Information System (INIS)

    Jun, S. M.; Suh, E. K.; Shim, H. B.; Kim, T. W.; Lee, B. Y.

    1998-01-01

    Bolted opening structures is widely applied for class 1 machinery of nuclear plant with strict design requirement. As the shape of the bolted opening structure is non-axisymmetric due to the existence of stud bolts although it is almost axi-symmetric, 3D analysis is required to satisfy such kind of design requirements. Because as much as possible trial computations are need to get an optimal design condition in the limited period of basic design, an easy and fast analysis tool is useful in the design stage. In the paper, a transformation technique of non-axisymmetric problem into quasi-axisymmetric has been proposed based on the general purpose commercial code ANSYS. Both the pre-processor which incorporates the technique and prepares data and post-processor which prepares arranged results from the huge output of commercial code have been developed to help the design engineers. (author)

  8. Investigating the effect of clamping force on the fatigue life of bolted plates using volumetric approach

    International Nuclear Information System (INIS)

    Esmaeili, F.; Chakherlou, T. N.; Zehsaz, M.; Hasanifard, S.

    2013-01-01

    In this paper, the effects of bolt clamping force on the fatigue life for bolted plates made from Al7075-T6 have been studied on the values of notch strength reduction factor obtained by volumetric approach. To attain stress distribution around the notch (hole) which is required for volumetric approach, nonlinear finite element simulations were carried out. To estimate the fatigue life, the available smooth S-N curve of Al7075-T6 and the notch strength reduction factor obtained from volumetric method were used. The estimated fatigue life was compared with the available experimental test results. The investigation shows that there is a good agreement between the life predicted by the volumetric approach and the experimental results for various specimens with different amount of clamping forces. Volumetric approach and experimental results showed that the fatigue life of bolted plates improves because of the compressive stresses created around the plate hole due to clamping force.

  9. Simulation and design of ECT differential bobbin probes for the inspection of cracks in bolts

    Science.gov (United States)

    Ra, S. W.; Im, K. H.; Lee, S. G.; Kim, H. J.; Song, S. J.; Kim, S. K.; Cho, Y. T.; Woo, Y. D.; Jung, J. A.

    2015-12-01

    All Various defects could be generated in bolts for a use of oil filters for the manufacturing process and then may affect to the safety and quality in bolts. Also, fine defects may be imbedded in oil filter system during multiple forging manufacturing processes. So it is very important that such defects be investigated and screened during the multiple manufacturing processes. Therefore, in order effectively to evaluate the fine defects, the design parameters for bobbin-types were selected under a finite element method (FEM) simulations and Eddy current testing (ECT). Especially the FEM simulations were performed to make characterization in the crack detection of the bolts and the parameters such as number of turns of the coil, the coil size and applied frequency were calculated based on the simulation results.

  10. An experimental study on inelastic behavior for exposed-type steel column bases under three-dimensional loadings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Hyouk [Chosun University, Gwangju (Korea, Republic of); Choi, Yeol [Kyungpook National University, Daegu (Korea, Republic of)

    2013-03-15

    Considerable damage occurred to steel structures during the Kobe earthquake in Japan. Numerous exposed-type column bases failed in several consistent patterns caused by brittle base plate fracture, excessive anchor bolt elongation, unexpected early anchor bolt failure, and inferior construction work. An exposed-type column base receives axial force and biaxial bending when receiving an arbitrary multidirectional earthquake motion. Up to now, numerous researchers have examined methods to identify their stiffness and strength, but those studies have heretofore been restricted to in-plane behaviors. Therefore, it is necessary to clarify the inelastic behavior of exposed type steel column bases under biaxial lateral loading and axially compressive-tensile loading, which is a closer simulation of the real seismic excitation. In this study, exposed type steel column bases with different failure types, anchor bolt yielding and base plate yielding, are tested under different loading programs, then moment resisting mechanisms and failure modes are investigated.

  11. An experimental study on inelastic behavior for exposed-type steel column bases under three-dimensional loadings

    International Nuclear Information System (INIS)

    Choi, Jae Hyouk; Choi, Yeol

    2013-01-01

    Considerable damage occurred to steel structures during the Kobe earthquake in Japan. Numerous exposed-type column bases failed in several consistent patterns caused by brittle base plate fracture, excessive anchor bolt elongation, unexpected early anchor bolt failure, and inferior construction work. An exposed-type column base receives axial force and biaxial bending when receiving an arbitrary multidirectional earthquake motion. Up to now, numerous researchers have examined methods to identify their stiffness and strength, but those studies have heretofore been restricted to in-plane behaviors. Therefore, it is necessary to clarify the inelastic behavior of exposed type steel column bases under biaxial lateral loading and axially compressive-tensile loading, which is a closer simulation of the real seismic excitation. In this study, exposed type steel column bases with different failure types, anchor bolt yielding and base plate yielding, are tested under different loading programs, then moment resisting mechanisms and failure modes are investigated

  12. Causes of Failure of High-Tensile Stud Bolts Used for Joining Metal Parts of Tower Crane

    Science.gov (United States)

    Tingaev, A. K.; Gubaydulin, R. G.; Shaburova, N. A.

    2017-11-01

    The causes of the failure of a high-tensile stud 2M48-6gx500 10.9 made from steel grade 30HGSA which led to a temporary inoperability of a tower crane were investigated. The bolts were used to assemble the tower sections and collapsed after 45 days from the moment the crane was commissioned. The cracks in the fracture are identified as fatigue with the characteristic sites of nucleation, sustainable development and static dolomite. To determine the possible causes of stud bolts destruction, metallographic, durometric and mechanical tests were carried out from which it follows that the stud bolt material in its original state corresponded to the delivery conditions. The destruction of the stud bolt appears to have resulted from a combination of several unfavorable factors: uncertainty about the actual tension of the stud bolt due to the lack of information about the magnitude of the twist factor; partial displacement of the centers of the brackets holes and rotation of the stud bolt axis during the sections’ assembly; no tight contact on the support surfaces of the section brackets. All this led to a discrepancy between the actual design of the stud bolt, the appearance of additional forces and the destruction of the stud bolt.

  13. Application of Long Expansion Rock Bolt Support in the Underground Mines of Legnica–Głogów Copper District

    Directory of Open Access Journals (Sweden)

    Skrzypkowski Krzysztof

    2017-09-01

    Full Text Available In the underground mines of the Legnica–Głogów Copper District (LGOM the main way to protect the room excavation is the use of a rock bolt support. For many years, it has proven to be an efficient security measure in excavations which met all safety standards and requirements. The article presents the consumption of the rock bolt support in the Mining Department “Polkowice–Sieroszowice” in the years 2010–2015 as well as the number of bolt supports that were used to secure the excavations. In addition, it shows the percentage of bolt supports that were used to conduct rebuilding work and cover the surface of exposed roofs. One of the factors contributing to the loss of the functionality of bolt supports is corrosion whose occurrence may lead directly to a reduction in the diameter of rock bolt support parts, in particular rods, bearing plates and nuts. The phenomenon of the corrosion of the bolt support and its elements in underground mining is an extremely common phenomenon due to the favorable conditions for its development in mines, namely high temperature and humidity, as well as the presence of highly aggressive water. This involves primarily a decrease in the capacity of bolt support construction, which entails the need for its strengthening, and often the need to perform the reconstruction of the excavation.

  14. Ultrasonic Inspection of Cracks in Stud Bolts of Reactor Vessels in Nuclear Power Plants by Signal Processing of Differential Operation

    International Nuclear Information System (INIS)

    Choi, Sang Woo; Lee, Joon Hyun; Oh, Won Deok

    2005-01-01

    The stud bolt is one of crucial parts for safe operation of reactor vessels in nuclear power plants, Crack initiation and propagation were reported in stud bolts that arc used for closure of reactor vessel and head, Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure which could induce radioactive leakage from nuclear reactor, In conventional ultrasonic testing for inspection of stud bolts, cracks are detected by using shadow effect It takes too much time to inspect stud bolts by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread, In this study, the signal processing technique for enhancing conventional ultrasonic technique was introduced for inspecting stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. Detectability for small crack was enhanced by using this signal processing in ultrasonic inspection of stud bolts in Nuclear Power Plants

  15. 14 CFR 27.865 - External loads.

    Science.gov (United States)

    2010-01-01

    ... 200 volts per meter. (iii) Be protected against any failure that could be induced by a failure mode of... transportable and releasable throughout the approved operational envelope without hazard to the rotorcraft... except for the failure of critical structural elements that would result in a hazard to the rotorcraft...

  16. Response of garlic (Allium sativum L. bolting and bulbing to temperature and photoperiod treatments

    Directory of Open Access Journals (Sweden)

    Cuinan Wu

    2016-04-01

    Full Text Available This research was conducted to evaluate the effect of temperature and photoperiod treatments on the bolting and bulb formation of three local garlic cultivars (cvs in two consecutive years. Naturally vernalized plants of cvs G107, G025 and G064 were transplanted into growth chambers and subjected to various combinations of temperature [T15/10, 15°C/10°C; T20/15, 20°C/15°C and T25/18, 25°C/18°C (day/night] and photoperiod (L8, 8 h and L14,14 h treatments. Plant growth, endogenous phytohormone and methyl jasmonate (MeJA levels, along with the bolting and yield of garlic were evaluated. The experimental results from two consecutive years indicated that higher temperature (20°C or 25°C and longer photoperiod (14 h treatments significantly enhanced the garlic bolting, bulbing and cloving with a shorter growth period and a higher bulb weight. Moreover, the endogenous phytohormone and MeJA levels in the test plants were significantly increased by the higher temperature (25°C for the phytohormone level; 20°C for the MeJA level and longer photoperiod [14 h, except for abscisic acid (ABA, which had the highest level at 8 h] conditions and were decreased by the lowest test temperature (15°C and shorter photoperiod (8 h, except for ABA conditions. This response coincided with that of the bulbing index, bolting rate, growth period and bulb weight. In addition, plants treated under the conditions of 20°C/15°C–14 h and 25°C/18°C–14 h produced the highest phytohormone levels (except for ABA for cvs G025 and G064, respectively, and showed the best bolting and bulbing behavior. It is reasonable to assume that endogenous phytohormone (especially gibberellic acid and MeJA levels are highly related to garlic bolting and bulbing, which might lead to the different responses of the three studied cultivars to the combination of temperature and photoperiod treatments. Furthermore, cvs G107 and G025 bolt well and have better bulb

  17. Stud-bolts strength for cell-liner design under shearing deformation

    International Nuclear Information System (INIS)

    Watashi, Katsumi; Nakanishi, Seiji

    1991-01-01

    This paper presents experimental and analytical stud-bolt strength subjected to large shearing deformation at high temperature. Tensile test result of the material, SM41B, was shown in the range of room temperature to 550degC at 10 -3 and 10 -4 m/m/s in strain rate. Shearing fracture test result of the stud-bolt is shown at room temperature and 530degC. Shearing fracture criterion was discussed based on both test results and FEM analysis result. (author)

  18. Comportamiento mecánico de las juntas tipo T-bolt en materiales compuestos gruesos

    OpenAIRE

    Martínez Moll, Víctor

    2003-01-01

    En aquest treball s'ha realitzat una anàlisi de la junta T-bolt aplicada a la unió de laminats gruixuts amb elements metàl·lics. Més concretament, l'estudi es centra en el tipus de juntes T-bolt emprades en la unió entre les pales i la boixa de grans aerogeneradors, que constitueix una de les principals aplicacions d'aquest tipus de junta.En primer lloc, s'ha realitzat una anàlisi simplificada dels factors que influeixen al comportament de la junta, a partir del qual es justifica la necessit...

  19. Theoretical Calculation and Analysis on the Composite Rock-Bolt Bearing Structure in Burst-Prone Ground

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2015-01-01

    Full Text Available Given the increase in mining depth and intensity, tunnel failure as a result of rock burst has become an important issue in the field of mining engineering in China. Based on the Composite Rock-Bolt Bearing Structure, which is formed due to the interaction of the bolts driven into the surrounding rock, this paper analyzes a rock burst prevention mechanism, establishes a mechanical model in burst-prone ground, deduces the strength calculation formula of the Composite Rock-Bolt Bearing Structure in burst-prone ground, and confirms the rock burst prevention criterion of the Composite Rock-Bolt Bearing Structure. According to the rock burst prevention criterion, the amount of the influence on rock burst prevention ability from the surrounding rock parameters and bolt support parameters is discussed.

  20. Pull-out test of stud bolts embedded in concrete under an in-plane force

    International Nuclear Information System (INIS)

    Inada, Y.; Saito, H.; Torita, H.; Takiguchi, K.; Ibe, Y.; Taira, T.

    1995-01-01

    There are many steel plates with stud bolts embedded in the R C walls of a nuclear reactor building to support equipment and piping. Under a earthquake, the steel plates are submitted to an out-of-plane force due to the inertia force acting upon equipment and piping. Furthermore, the walls are submitted to an in-plane force, and cracks may occur. A large number of experimental studies have been carried out on the pull-out strength of stud bolts embedded in concrete. Few studies have been performed to understand the strength of stud bolts embedded in concrete under an in-plane force and, further, not any one on the strength for concrete under in-plane force simultaneously to stud bolts under out-of-plane force. This paper describes a test performed to understand the pull-out strength determined by this interaction of in-plane and out-of-plane forces. (author). 5 refs., 9 figs., 5 tabs

  1. Review and synthesis of stress intensity factor solutions applicable to cracks in bolts

    International Nuclear Information System (INIS)

    James, L.A.; Mills, W.J.

    1988-01-01

    The available literature for stress intensity factor solutions for cracks in round bars, both threaded and unthreaded, subjected to either tension or bending, is reviewed. The results are synthesized into a form that is appropriate for the analysis of bolts and studs. (author)

  2. Seismic Properties of Moment-resisting Timber Joints with a Combination of Bolts and Nails

    Directory of Open Access Journals (Sweden)

    Awaludin A.

    2011-01-01

    Full Text Available Improvement of cyclic or dynamic performance of timber connections has been intensively conducted since the overall response of wooden structures is merely a function of joint performance. For a bolted joint, filling the lead-hole clearance with epoxy resin or gluing high embedding-strength materials at the interface of the individual timber member are probably the most common methods. This study presents cyclic test results of moment-resisting joints with a combination of bolts and nails. The nails were placed closer to the joint centroid than the bolts, acting as additional fasteners and were expected to improve the seismic performance of the joints. Static-cyclic test results confirmed the increase of joint stiffness and moment resistance due to the additional nails. The nails contribute to the increase of hysteretic damping significantly though pinching behavior or narrowing the hysteresis loops close to zero rotation points was still observed. The results indicated that contribution of nails or bolts on moment resistance and hysteretic damping can be superimposed.

  3. 77 FR 32698 - Proposed Extension of Existing Information Collection; Safety Standards for Roof Bolts in Metal...

    Science.gov (United States)

    2012-06-01

    ... are used to prevent the fall of roof, face, and rib. Advancements in technology of roof and rock bolts... information technology (e.g., permitting electronic submissions of responses), to minimize the burden of the...-0121. Affected Public: Business or other for-profit. Cite/Reference/Form/ etc. 30 CFR 56.3203, 57.3203...

  4. 3D finite element analysis of tightening process of bolt and nut connections with pitch difference

    Science.gov (United States)

    Liu, X.; Noda, N.-A.; Sano, Y.; Huang, Y. T.; Takase, Y.

    2018-06-01

    In a wide industrial field, the bolt-nut joint is unitized as an important machine element and anti-loosening performance is always required. In this paper, the effect of a slight pitch difference between a bolt and nut is studied. Firstly, by varying the pitch difference, the prevailing torque required for the nut rotation, before the nut touches the clamped body, is measured experimentally. Secondly, the tightening torque is determined as a function of the axial force of the bolt after the nut touches the clamped body. The results show that a large value of pitch difference may provide large prevailing torque that causes an anti-loosening effect although a very large pitch difference may deteriorate the bolt axial force under a certain tightening torque. Thirdly, a suitable pitch difference is determined taking into account the anti-loosening and clamping abilities. Furthermore, the chamfered corners at nut ends are considered, and it is found that the 3D finite element analysis with considering the chamfered nut threads has a good agreement with the experimental observation. Finally, the most desirable pitch difference required for improving anti-loosening is proposed.

  5. Mechanical tests of the bolt of the gripper latch on the control rod cluster

    International Nuclear Information System (INIS)

    Lemaire, E.; Couet, D.; Molinie, D.; Grandjean, Y.; Radat, M.P.; Guttmann, D.

    1998-01-01

    Failure analysis and mechanical testing indicate that control rod drive mechanisms malfunctioning by 1995-96 is due to rupture by fatigue of a bolt inside the stationary gripper assembly. Fatigue is enhanced by free working following surface adaptation and unscrewing of the assembly. These results are taken into account for the choice of a new anti-rotation device. (authors)

  6. Special requirements for bolting material for nuclear and other special applications

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    A specification that provides special requirements for bolting material for use in nuclear and other special applications is presented. The requirements of the specification are supplemental to the requirements of the basic material specifications and they include tempering, welding, elimination of surface defects, certification and identification, quality assurance and various examination methods

  7. A Smart Washer for Bolt Looseness Monitoring Based on Piezoelectric Active Sensing Method

    Directory of Open Access Journals (Sweden)

    Heyue Yin

    2016-10-01

    Full Text Available Piezoceramic based active sensing methods have been researched to monitor preload on bolt connections. However, there is a saturation problem involved with this type of method. The transmitted energy is sometimes saturated before the maximum preload which is due to it coming into contact with flat surfaces. When it comes to flat contact surfaces, the true contact area will easily saturate with the preload. The design of a new type of bolt looseness monitoring sensor, a smart washer, is to mitigate the saturation problem. The smart washer is composed of two annular disks with contact surfaces that are machined into convex and concave respectively, to eliminate the complete flat contact surfaces and to reduce the saturation effect. One piezoelectric patch is bonded on the non-contact surface of each annular disk. These two mating annular disks form a smart washer. One of the two piezoelectric patches serves as an actuator to generate an ultrasonic wave that propagates through the contact surface; the other one serves as a sensor to detect the propagated waves. The wave energy propagated through the contact surface is proportional to the true contact area which is determined by the bolt preload. The time reversal method is used to extract the peak of the focused signal as the index of the transmission wave energy; then, the relationship between the signal peak and bolt preload is obtained. Experimental results show that the focused signal peak value changes with the bolt preload and presents an approximate linear relationship when the saturation problem is experienced. The proposed smart washer can monitor the full range of the rated preload.

  8. A structural health monitoring fastener for tracking fatigue crack growth in bolted metallic joints

    Science.gov (United States)

    Rakow, Alexi Schroder

    Fatigue cracks initiating at fastener hole locations in metallic components are among the most common form of airframe damage. The fastener hole site has been surveyed as the second leading initiation site for fatigue related accidents of fixed wing aircraft. Current methods for inspecting airframes for these cracks are manual, whereby inspectors rely on non-destructive inspection equipment or hand-held probes to scan over areas of a structure. Use of this equipment often demands disassembly of the vehicle to search appropriate hole locations for cracks, which elevates the complexity and cost of these maintenance inspections. Improved reliability, safety, and reduced cost of such maintenance can be realized by the permanent integration of sensors with a structure to detect this damage. Such an integrated system of sensors would form a structural health monitoring (SHM) system. In this study, an Additive, Interleaved, Multi-layer Electromagnetic (AIME) sensor was developed and integrated with the shank of a fastener to form a SHM Fastener, a new SHM technology targeted at detection of fastener hole cracks. The major advantages of the SHM Fastener are its installation, which does not require joint layer disassembly, its capability to detect inner layer cracks, and its capability to operate in a continuous autonomous mode. Two methods for fabricating the proposed SHM Fastener were studied. The first option consisted of a thin flexible printed circuit film that was bonded around a thin metallic sleeve placed around the fastener shank. The second option consisted of coating sensor materials directly to the shank of a part in an effort to increase the durability of the sensor under severe loading conditions. Both analytical and numerical models were developed to characterize the capability of the sensors and provide a design tool for the sensor layout. A diagnostic technique for crack growth monitoring was developed to complete the SHM system, which consists of the

  9. Analysis of WWER 440 SG primary collector bolted joint damage

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K.; Wozniak, J. [Vitkovice J.S.C., Ostrava (Switzerland); Pochman, K. [NPP Dukovany (Switzerland)

    1997-12-31

    The susceptibility of CHN35VT-VD and 08CH18N10T stainless steels to stress corrosion cracking in water environment, simulating water solution found in threaded holes, was investigated using rising load line displacement tests of precracked C(T) specimens. To judge the role of oxidant on stress corrosion cracking of both stainless steels, the effect of dissolved oxygen content (fully deaerated water, water aerated at the beginning of the test) was studied. 7 refs.

  10. Analysis of WWER 440 SG primary collector bolted joint damage

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K; Wozniak, J [Vitkovice J.S.C., Ostrava (Switzerland); Pochman, K [NPP Dukovany (Switzerland)

    1998-12-31

    The susceptibility of CHN35VT-VD and 08CH18N10T stainless steels to stress corrosion cracking in water environment, simulating water solution found in threaded holes, was investigated using rising load line displacement tests of precracked C(T) specimens. To judge the role of oxidant on stress corrosion cracking of both stainless steels, the effect of dissolved oxygen content (fully deaerated water, water aerated at the beginning of the test) was studied. 7 refs.

  11. Investigation on the Influence of Abutment Pressure on the Stability of Rock Bolt Reinforced Roof Strata Through Physical and Numerical Modeling

    Science.gov (United States)

    Kang, Hongpu; Li, Jianzhong; Yang, Jinghe; Gao, Fuqiang

    2017-02-01

    In underground coal mining, high abutment loads caused by the extraction of coal can be a major contributor to many rock mechanic issues. In this paper, a large-scale physical modeling of a 2.6 × 2.0 × 1.0 m entry roof has been conducted to investigate the fundamentals of the fracture mechanics of entry roof strata subjected to high abutment loads. Two different types of roof, massive roof and laminated roof, are considered. Rock bolt system has been taken into consideration. A distinct element analyses based on the physical modeling conditions have been performed, and the results are compared with the physical results. The physical and numerical models suggest that under the condition of high abutment loads, the massive roof and the laminated roof fail in a similar pattern which is characterized as vertical tensile fracturing in the middle of the roof and inclined shear fracturing initiated at the roof and rib intersections and propagated deeper into the roof. Both the massive roof and the laminated roof collapse in a shear sliding mode shortly after shear fractures are observed from the roof surface. It is found that shear sliding is a combination of tensile cracking of intact rock and sliding on bedding planes and cross joints. Shear sliding occurs when the abutment load is much less than the compressive strength of roof.

  12. Measurements of heat transfer coefficients at low contact pressures for actively cooled bolted armour concepts in Tore Supra

    International Nuclear Information System (INIS)

    Lipa, M.; Chappuis, Ph.; Dufayet, A.

    2000-01-01

    For the future upgrade of inner vessel components (CIEL project) a guard limiter for plasma ramp-up and disruption protection will be installed on the high field side of the vacuum vessel. Among transient heat loads, this structure has to sustain a moderate heat flux in the range of ≤0.5 MW/m 2 during quasi steady state operation (1000 s). A bolted carbon-carbon (C-C) tile is preferred compared with a brazed tile solution due to the expected moderate heat fluxes, costs and the possibility of rapid replacement of individual tiles. Large flat tile assemblies require a sufficient soft and conductive compliant layer enclosed between tile and heat sink in order to avoid thermal contact loss of the assembly during heat loads and therefore minimising the tile surface temperature. The global heat transfer coefficient (H gl ) under vacuum at low contact pressures (0.5-1.5 MPa) between C-C and CuCrZr heat sink substrata has been measured in the experimental device, installation of contact heat transfer measurements (ITTAC), using different compliant materials. It appears that the best compliant layer is a graphite sheet (PAPYEX), compared with copper-felt/foam material. As an example, a H gl number of ∼10 4 W/m 2 K at an average contact pressure of 0.5 MPa has been measured near room temperature between C-C (SEP N11) and CuCrZr substrata using a 0.5-mm thick PAPYEX layer. Thermohydraulic calculations (2D) of the guard limiter design show an expected tile surface temperature of about 550 deg. C in steady state regime for an incident heat flux of 0.5 MW/m 2

  13. Analytical and numerical investigation of bolted steel ring flange connection for offshore wind monopile foundations

    DEFF Research Database (Denmark)

    Madsen, C.A.; Kragh-Poulsen, Jens-Christian; Tage, K.J.

    The monopile foundation is the dominant solution for support of wind turbines in offshore wind farms. It is normally grouted to the transition piece which connects the foundation to the turbine. Currently, the bolted steel ring flange connection is investigated as an alternative. The monopile......--transition piece connection has specific problems, such as out-of-verticality and installation damage from driving the MP into the seabed and it is not fully known how to design for these. This paper presents the status of the ongoing development work and an estimate of what still needs to be covered in order...... to use the connection in practice. This involves presentation of an analytical and non-linear FE analysis procedure for the monopile-transition piece connection composed of two L flanges connected with preloaded bolts. The connection is verified for ultimate and fatigue limit states based...

  14. Analytical and numerical investigation of bolted steel ring flange connection for offshore wind monopile foundations

    DEFF Research Database (Denmark)

    Madsen, C.A.; Kragh-Poulsen, Jens-Christian; Tage, K.J.

    2017-01-01

    The monopile foundation is the dominant solution for support of wind turbines in offshore wind farms. It is normally grouted to the transition piece which connects the foundation to the turbine. Currently, the bolted steel ring flange connection is investigated as an alternative. The monopile......--transition piece connection has specific problems, such as out-of-verticality and installation damage from driving the MP into the seabed and it is not fully known how to design for these. This paper presents the status of the ongoing development work and an estimate of what still needs to be covered in order...... to use the connection in practice. This involves presentation of an analytical and non-linear FE analysis procedure for the monopile-transition piece connection composed of two L flanges connected with preloaded bolts. The connection is verified for ultimate and fatigue limit states based...

  15. Suicide with two makes of captive-bolt guns (livestock stunners) fired simultaneously to the forehead.

    Science.gov (United States)

    Pircher, Rebecca; Geisenberger, Dorothee; Große Perdekamp, Markus; Neukamm, Merja; Pollak, Stefan; Schmidt, Ulrike; Thierauf-Emberger, Annette

    2017-11-01

    In humans, most fatalities from slaughterer's guns are suicides committed by persons familiar with stunning devices. The great majority of cases accounts for shots to the head, especially the frontal region. Only a small number of two subsequent cranial shots from captive-bolt humane killers have been reported up to now. In the case presented by the authors, a suicide by simultaneous shots to the head fired from two different makes of captive-bolt guns (one of them having two separate outlets for the combustion gases in the muzzle plane, the other type having no additional openings) is described for the first time. One of the shooting devices remained in firm contact with the left hand and produced patterned staining from rust corresponding to the surface relief of the gun. The medicolegal and criminalistic aspects of this unique case are discussed with reference to the pertinent literature.

  16. Failure analysis of the stud bolt of a canned motor pump of heavy water plant, Talcher

    International Nuclear Information System (INIS)

    Kumar, Sunil; Sethumadhavan, V.; Sah, D.N.; Sivaramakrishnan, K.S.; Kain, Vivekanand; Gadiyar, H.S.

    1990-01-01

    Detailed investigations have been carried out on the failed stud bolts (made of DIN 1.4021 X 20Cr 13) of a canned motor pump of Heavy Water Plant, Talcher, using metallographic, microhardness testing, scanning electron microscopy and electron probe micro-analysis(EPMA) techniques. The studs had failed in a brittle manner in the mid-length portion. The origin of the fracture has been identified to be a corroded region on the stud surface. Branching cracks propagating through silicon rich inclusions have been noted. Two types of inclusions, one containing Mn and S and other containing S, Mn and O 2 have been found in the material. Clusters of large and small inclusions of the above types have been found near the origin of the fracture. It has been concluded that the fracture was caused by corrosion fatigue, initiating at the cluster of inclusions present on the surface of the stud bolts. (author). 7 refs., 5 figs

  17. On the performance of Usain Bolt in the 100 m sprint

    Science.gov (United States)

    Hernández Gómez, J. J.; Marquina, V.; Gómez, R. W.

    2013-09-01

    Many university texts on mechanics consider the effect of air drag force, using the slowing down of a parachute as an example. Very few discuss what happens when the drag force is proportional to both u and u2. In this paper we deal with a real problem to illustrate the effect of both terms on the speed of a runner: a theoretical model of the world-record 100 m sprint of Usain Bolt during the 2009 World Championships in Berlin is developed, assuming a drag force proportional to u and to u2. The resulting equation of motion is solved and fitted to the experimental data obtained from the International Association of Athletics Federations, which recorded Bolt's position with a laser velocity guard device. It is worth noting that our model works only for short sprints.

  18. PERL - European research project on characterization of gaskets for bolted flange connections

    International Nuclear Information System (INIS)

    Kockelmann, H.; Hahn, R.

    2004-01-01

    Great progress was observed in the European standardization in the last years in the field of the design of floating type bolted flange connections. New design rules were developed (EN 1591) which include new definitions of gasket characteristics for the calculation of floating type flanged joints. In addition a new gasket testing standard was drafted (prEN 13555) which assures a comprehensive characterization of gaskets for bolted flanged joints. This draft standard contains some new features which were examined and validated within the European research project PERL (Pressure Equipment - Reduction of Leak Rate). The gasket testing strategy laid down in prEN 13555 is presented in this paper. Some testing results highlighten the measuring procedures and the evaluation of the gasket characteristics. (orig.)

  19. Flanged joints with contact outside the bolt circle: ASME Part B design rules

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1976-05-01

    The ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, gives rules which are subdivided into ''Part A'' and ''Part B''. Part A covers flanged joints where contact between flanges occurs through a gasket located inside the bolt holes. Part B covers flanged joints with contact outside the bolt holes. This report (a) summarizes the theory for Part B flanged joints, (b) presents examples which show the significant differences between Part A flanged joints and Part B flanged joints, (c) presents the available test data relevant to the characteristics of Part B flanged joints, (d) gives listings of two computer programs which can be used to evaluate the characteristics of Part B flanged joints, and (e) gives recommendations for Code revisions and other aspects of Part B flanged-joint design

  20. Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung Hee; Yun, Chung Bang [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Inman, Daniel J. [Virginia Polytechnic Institute and State University, Virginia (United States)

    2007-06-15

    This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure

  1. Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

    International Nuclear Information System (INIS)

    Park, Seung Hee; Yun, Chung Bang; Inman, Daniel J.

    2007-01-01

    This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure

  2. Interaction between an Eco-Spiral Bolt and Crushed Rock in a Borehole Evaluated by Pull-Out Testing

    Directory of Open Access Journals (Sweden)

    Seong-Seung Kang

    2017-01-01

    Full Text Available The interactions between an eco-spiral bolt and crushed rocks in a borehole were evaluated by pull-out testing in a laboratory and numerical analysis. The porosity of the crushed rock surrounding the bolt depended on the size of the eco-spiral bolt and affected the eco-spiral bolt’s axial resistance force. The axial resistance force and the porosity of the crushed rocks in the borehole showed an inverse relationship. The porosity was also related to the size of the eco-spiral bolt. The maximum principal stress between the bolt and the rock was related to the porosity of the crushed rock and the size difference between the eco-spiral bolt and the borehole. At low porosity the experimental and numerical analyses show similar relationships between the axial resistance force and the displacement. However, at high porosity, the numerical results deviated greatly from the experimental observation. The initial agreement is attributed to the state of residual resistance after the maximum axial resistance force, and the latter divergence was due to the decreasing axial resistance force owing to slippage.

  3. On load paths and load bearing topology from finite element analysis

    International Nuclear Information System (INIS)

    Kelly, D; Reidsema, C; Lee, M

    2010-01-01

    Load paths can be mapped from vector plots of 'pointing stress vectors'. They define a path along which a component of load remains constant as it traverses the solution domain. In this paper the theory for the paths is first defined. Properties of the plots that enable a designer to interpret the structural behavior from the contours are then identified. Because stress is a second order tensor defined on an orthogonal set of axes, the vector plots define separate paths for load transfer in each direction of the set of axes. An algorithm is therefore presented that combines the vectors to define a topology to carry the loads. The algorithm is shown to straighten the paths reducing bending moments and removing stress concentration. Application to a bolted joint, a racing car body and a yacht hull demonstrate the usefulness of the plots.

  4. Further development of remote testing of submerged bolts and screws in reactors

    International Nuclear Information System (INIS)

    Mohr, F.; Schirner, G.; Meier, R.; Wiesinger, W.

    2007-01-01

    Since the eighties, intelligeNDT has been carrying out ultrasonic tests of bolts in reactor containments and pressure vessels both in Germany and abroad. The ultrasonic equipment used belonged to the SAPHIR/SAPHIRplus line. The recording and online evaluation software was adapted to the test requirements and optimized for high test rates and quality-assured documentation. As test manipulator, the ''SUSI'' submarine by AREVA NP was used with good results. (orig.)

  5. Dynamic modeling method of the bolted joint with uneven distribution of joint surface pressure

    Science.gov (United States)

    Li, Shichao; Gao, Hongli; Liu, Qi; Liu, Bokai

    2018-03-01

    The dynamic characteristics of the bolted joints have a significant influence on the dynamic characteristics of the machine tool. Therefore, establishing a reasonable bolted joint dynamics model is helpful to improve the accuracy of machine tool dynamics model. Because the pressure distribution on the joint surface is uneven under the concentrated force of bolts, a dynamic modeling method based on the uneven pressure distribution of the joint surface is presented in this paper to improve the dynamic modeling accuracy of the machine tool. The analytic formulas between the normal, tangential stiffness per unit area and the surface pressure on the joint surface can be deduced based on the Hertz contact theory, and the pressure distribution on the joint surface can be obtained by the finite element software. Futhermore, the normal and tangential stiffness distribution on the joint surface can be obtained by the analytic formula and the pressure distribution on the joint surface, and assigning it into the finite element model of the joint. Qualitatively compared the theoretical mode shapes and the experimental mode shapes, as well as quantitatively compared the theoretical modal frequencies and the experimental modal frequencies. The comparison results show that the relative error between the first four-order theoretical modal frequencies and the first four-order experimental modal frequencies is 0.2% to 4.2%. Besides, the first four-order theoretical mode shapes and the first four-order experimental mode shapes are similar and one-to-one correspondence. Therefore, the validity of the theoretical model is verified. The dynamic modeling method proposed in this paper can provide a theoretical basis for the accurate dynamic modeling of the bolted joint in machine tools.

  6. Estimation for bolt fastening conditions of thin aluminum structure using PZT sensors

    International Nuclear Information System (INIS)

    Hong, Yong; Han, Byeong Hee; Kim, Byung Jin; Hong, Dong Pyo; Kim, Young Moon

    2007-01-01

    This work presents a study on PZT impedance-based method, it is one of the NDT(Non-Destructive Technique). We study about assessment of the square-structure health condition by impedance-based technique using PZT patches, associated with longitudinal wave propagation. Health conditions of the square-structure controlled by bolt fastening condition is adjusted by torque wrench. In order to estimate the damage condition numerically, we suggest the evaluation method of impedance peak frequency shift

  7. Experimental study on tunnel lining joints temporarily strengthened by SMA bolts

    International Nuclear Information System (INIS)

    Wu, Bo; Ou, Yunlong

    2014-01-01

    Shield tunnels have been widely used in city metros all over the world. During the long-term period of the metro operation, the joints of shield tunnel’s neighboring segments may degrade due to some environmental factors, leading to the increasing of the joint opening and some resulting adverse consequences. In this paper, a temporary strengthening method by using shape memory alloy (SMA) bolts is proposed and experimentally studied for the joints of neighboring segments, and a revised electric heating method which suits with the strengthening method is presented and experimentally validated for the SMA bolts. The purpose of the proposed temporary strengthening method is to create favorable conditions for the following permanent strengthening. Test results show that: (a) for the joints of shield tunnel’s neighboring segments, the strengthening method can effectively reduce the joint opening, joint deflection, concrete strain in joint’s compression zone, and strain of joint’s steel bolts; (b) the revised electric heating method can be used to heat the SMA rod to a temperature higher than the SMA’s austenite finish temperature quickly, and the average heating rate related to Type 2 inner resistance element is larger than that related to Type 1 inner resistance element; and (c) the reduction percentages of the joint opening increment, joint deflection, concrete strain in joint’s compression zone, and strain of joint’s steel bolts for Specimen I are all larger than those for Specimen II, implying that the less the joint opening is, the more significant the strengthening effect is. (paper)

  8. Holographic description of Kerr-Bolt-AdS-dS spacetimes

    International Nuclear Information System (INIS)

    Chen, B.; Ghezelbash, A.M.; Kamali, V.; Setare, M.R.

    2011-01-01

    We show that there exists a holographic 2D CFT description of a Kerr-Bolt-AdS-dS spacetime. We first consider the wave equation of a massless scalar field propagating in extremal Kerr-Bolt-AdS-dS spacetimes and find in the 'near region', the wave equation in extremal limit could be written in terms of the SL(2,R) quadratic Casimir. This suggests that there exist dual CFT descriptions of these black holes. In the probe limit, we compute the scattering amplitudes of the scalar off the extremal black holes and find perfect agreement with the CFT prediction. Furthermore we study the holographic description of the generic four-dimensional non-extremal Kerr-Bolt-AdS-dS black holes. We find that if focusing on the near-horizon region, for the massless scalar scattering in the low-frequency limit, the radial equation could still be rewritten as the SL(2,R) quadratic Casimir, suggesting the existence of dual 2D description. We read the temperatures of the dual CFT from the conformal coordinates and obtain the central charges by studying the near-horizon geometry of near-extremal black holes. We recover the macroscopic entropy from the microscopic counting. We also show that for the super-radiant scattering, the retarded Green's functions and the corresponding absorption cross sections are in perfect match with CFT prediction.

  9. Holographic description of Kerr-Bolt-AdS-dS spacetimes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, B., E-mail: bchen01@pku.edu.c [Department of Physics, and State Key Laboratory of Nuclear Physics and Technology, and Center for High Energy Physics, Peking University, Beijing 100871 (China); Ghezelbash, A.M., E-mail: masoud.ghezelbash@usask.c [Department of Physics and Engineering Physics, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5E2 (Canada); Kamali, V., E-mail: vkamali1362@gmail.co [Department of Campus of Bijar, Kurdistan University, Bijar (Iran, Islamic Republic of); Setare, M.R., E-mail: rezakord@ipm.i [Department of Campus of Bijar, Kurdistan University, Bijar (Iran, Islamic Republic of)

    2011-07-01

    We show that there exists a holographic 2D CFT description of a Kerr-Bolt-AdS-dS spacetime. We first consider the wave equation of a massless scalar field propagating in extremal Kerr-Bolt-AdS-dS spacetimes and find in the 'near region', the wave equation in extremal limit could be written in terms of the SL(2,R) quadratic Casimir. This suggests that there exist dual CFT descriptions of these black holes. In the probe limit, we compute the scattering amplitudes of the scalar off the extremal black holes and find perfect agreement with the CFT prediction. Furthermore we study the holographic description of the generic four-dimensional non-extremal Kerr-Bolt-AdS-dS black holes. We find that if focusing on the near-horizon region, for the massless scalar scattering in the low-frequency limit, the radial equation could still be rewritten as the SL(2,R) quadratic Casimir, suggesting the existence of dual 2D description. We read the temperatures of the dual CFT from the conformal coordinates and obtain the central charges by studying the near-horizon geometry of near-extremal black holes. We recover the macroscopic entropy from the microscopic counting. We also show that for the super-radiant scattering, the retarded Green's functions and the corresponding absorption cross sections are in perfect match with CFT prediction.

  10. Ultrasonic inspection of studs (bolts) using dynamic predictive deconvolution and wave shaping.

    Science.gov (United States)

    Suh, D M; Kim, W W; Chung, J G

    1999-01-01

    Bolt degradation has become a major issue in the nuclear industry since the 1980's. If small cracks in stud bolts are not detected early enough, they grow rapidly and cause catastrophic disasters. Their detection, despite its importance, is known to be a very difficult problem due to the complicated structures of the stud bolts. This paper presents a method of detecting and sizing a small crack in the root between two adjacent crests in threads. The key idea is from the fact that the mode-converted Rayleigh wave travels slowly down the face of the crack and turns from the intersection of the crack and the root of thread to the transducer. Thus, when a crack exists, a small delayed pulse due to the Rayleigh wave is detected between large regularly spaced pulses from the thread. The delay time is the same as the propagation delay time of the slow Rayleigh wave and is proportional to the site of the crack. To efficiently detect the slow Rayleigh wave, three methods based on digital signal processing are proposed: wave shaping, dynamic predictive deconvolution, and dynamic predictive deconvolution combined with wave shaping.

  11. Detection and depth determination of corrosion defects in embedded bolts using ultrasonic testing technique

    International Nuclear Information System (INIS)

    Lin, Shan; Fukutomi, Hiroyuki; Yuya, Hideki; Ito, Keisuke

    2011-01-01

    A great number of anchor bolts are used to fix various components to concrete foundation in thermal and nuclear power plants. As aging power plants degrade, it is feared that defects resulted from corrosion may occur underground. In this paper, a measurement method utilizing the phased array technique is developed to detect such defects. Measurement results show that this method can detect local and circumferential corrosion defects introduced artificially, but defect echo position appears to be farther away from the bolt head than is actually the case. A finite element simulation of wave propagation shows that longitudinal waves excited by a phased array probe are mode converted and reflected at the defect and at bolt wall, which results in the position of the defect echo appearing to be farther away than the defect actually is. Moreover, an approach for determining the depth of defects using measurement results is also proposed based on numerical results. The depths determined by the proposed approach agree with the actual depths with a maximum error of 1.8 mm and a RMSE of 1.06 mm. (author)

  12. Transcriptomic analysis reveals the roles of gibberellin-regulated genes and transcription factors in regulating bolting in lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Liu, Xueying; Lv, Shanshan; Liu, Ran; Fan, Shuangxi; Liu, Chaojie; Liu, Renyi; Han, Yingyan

    2018-01-01

    A cool temperature is preferred for lettuce cultivation, as high temperatures cause premature bolting. Accordingly, exploring the mechanism of bolting and preventing premature bolting is important for agriculture. To explore this relationship in depth, morphological, physiological, and transcriptomic analyses of the bolting-sensitive line S39 at the five-leaf stage grown at 37°C were performed in the present study. Based on paraffin section results, we observed that S39 began bolting on the seventh day at 37°C. During bolting in the heat-treated plants, GA3 and GA4 levels in leaves and the indoleacetic acid (IAA) level in the stem reached a maximum on the sixth day, and these high contents were maintained. Additionally, bolting begins in the fifth day after GA3 treatment in S39 plants, GA3 and GA4 increased and then decreased, reaching a maximum on the fourth day in leaves. Similarly, IAA contents reached a maximum in the stem on the fifth day. No bolting was observed in the control group grown at 25°C, and significant changes were not observed in GA3 and GA4 levels in the controls during the observation period. RNA-sequencing data implicated transcription factors (TFs) in regulating bolting in lettuce, suggesting that the high GA contents in the leaves and IAA in the stem promote bolting. TFs possibly modulate the expression of related genes, such as those encoding hormones, potentially regulating bolting in lettuce. Compared to the control group, 258 TFs were identified in the stem of the treatment group, among which 98 and 156 were differentially up- and down-regulated, respectively; in leaves, 202 and 115 TFs were differentially up- and down-regulated, respectively. Significant changes in the treated group were observed for C2H2 zinc finger, AP2-EREBP, and WRKY families, indicating that these TFs may play important roles in regulating bolting.

  13. Impedance-Based Pre-Stress Monitoring of Rock Bolts Using a Piezoceramic-Based Smart Washer—A Feasibility Study

    Science.gov (United States)

    Wang, Bo; Huo, Linsheng; Chen, Dongdong; Li, Weijie; Song, Gangbing

    2017-01-01

    Pre-stress degradation or looseness of rock bolts in mining or tunnel engineering threatens the stability and reliability of the structures. In this paper, an innovative piezoelectric device named a “smart washer” with the impedance method is proposed with the aim of developing a real-time device to monitor the pre-stress level of rock bolts. The proposed method was verified through tests on a rock bolt specimen. By applying high-frequency sweep excitations (typically >30 kHz) to the smart washer that was installed on the rock bolt specimen, we observed that the variation in impedance signatures indicated the rock bolt pre-stress status. With the degradation of rock bolt pre-stress, the frequency in the dominating peak of the real part of the electrical impedance signature increased. To quantify the effectiveness of the proposed technique, a normalized root mean square deviation (RMSD) index was developed to evaluate the degradation level of the rock bolt pre-stress. The experimental results demonstrated that the normalized RMSD-based looseness index, which was computed from the impedance value detected by the “smart washer”, increased with loss of the pre-stress of the rock bolt. Therefore, the proposed method can effectively detect the degradation of rock bolt pre-stress, as demonstrated by experiments. PMID:28134811

  14. Identification of flowering-related genes responsible for differences in bolting time between two radish inbred lines

    Directory of Open Access Journals (Sweden)

    Hye Sun Cho

    2016-12-01

    Full Text Available Late bolting after cold exposure is an economically important characteristic of radish (Raphanus sativus L., an important Brassicaceae root vegetable crop. However, little information is available regarding the genes and pathways that govern flowering time in this species. We performed high-throughput RNA sequencing analysis to elucidate the molecular mechanisms that determine the differences in flowering times between two radish lines, NH-JS1 (late bolting and NH-JS2 (early bolting. In total, 71,188 unigenes were identified by reference-guided assembly, of which 309, 788, and 980 genes were differentially expressed between the two inbred lines after 0, 15, and 35 days of vernalization, respectively. Among these genes, 218 homologs of Arabidopsis flowering-time (Ft genes were identified in the radish, and 49 of these genes were differentially expressed between the two radish lines in the presence or absence of vernalization treatment. Most of the Ft genes up-regulated in NH-JS1 vs NH-JS2 were repressors of flowering, such as RsFLC, consistent with the late-bolting phenotype of NH-JS1. Although the functions of genes down-regulated in NH-JS1 were less consistent with late-bolting characteristics than the up-regulated Ft genes, several Ft enhancer genes, including RsSOC1, a key floral integrator, showed an appropriate expression to the late-bolting phenotype. In addition, the patterns of gene expression related to the vernalization pathway closely corresponded with the different bolting times of the two inbred lines. These results suggest that the vernalization pathway is conserved between radish and Arabidopsis.

  15. Stress analysis in a non axisymmetric loaded reactor pressure vessel

    International Nuclear Information System (INIS)

    Albuquerque, Levi Barcelos; Assis, Gracia Menezes V. de; Miranda, Carlos Alexandre J.; Cruz, Julio Ricardo B.; Mattar Neto, Miguel

    1995-01-01

    In this work we intend to present the stress analysis of a PWR vessel under postulated concentrated loads. The vessel was modeled with Axisymmetric solid 4 nodes harmonic finite elements with the use of the ANSYS program, version 5.0. The bolts connecting the vessel flanges were modeled with beam elements. Some considerations were made to model the contact between the flanges. The perforated part of the vessel tori spherical head was modeled (with reduced properties due to its holes) to introduce its stiffness and loads but was not within the scope of this work. The loading consists of some usual ones, as pressure, dead weight, bolts preload, seismic load and some postulated ones as concentrated loads, over the vessel, modeled by Fourier Series. The results in the axisymmetric model are taken in terms of linearized stresses, obtained in some circumferential positions and for each position, in some sections along the vessel. Using the ASME Code (Section III, Division 1, Sub-section NB) the stresses are within the allowable limits. In order to draw some conclusions about stress linearization, the membrane plus bending stresses (Pl + Pb) are obtained and compared in some sections, using three different methods. (author)

  16. Inflorescence Development and the Role of LsFT in Regulating Bolting in Lettuce (Lactuca sativa L.)

    Science.gov (United States)

    Chen, Zijing; Han, Yingyan; Ning, Kang; Ding, Yunyu; Zhao, Wensheng; Yan, Shuangshuang; Luo, Chen; Jiang, Xiaotang; Ge, Danfeng; Liu, Renyi; Wang, Qian; Zhang, Xiaolan

    2018-01-01

    Lettuce (Lactuca sativa L.) is one of the most important leafy vegetable that is consumed during its vegetative growth. The transition from vegetative to reproductive growth is induced by high temperature, which has significant economic effect on lettuce production. However, the progression of floral transition and the molecular regulation of bolting are largely unknown. Here we morphologically characterized the inflorescence development and functionally analyzed the FLOWERING LOCUS T (LsFT) gene during bolting regulation in lettuce. We described the eight developmental stages during floral transition process. The expression of LsFT was negatively correlated with bolting in different lettuce varieties, and was promoted by heat treatment. Overexpression of LsFT could recover the late-flowering phenotype of ft-2 mutant. Knockdown of LsFT by RNA interference dramatically delayed bolting in lettuce, and failed to respond to high temperature. Therefore, this study dissects the process of inflorescence development and characterizes the role of LsFT in bolting regulation in lettuce. PMID:29403510

  17. Testing of nuclear grade lubricants and their effects on A540 B24 and A193 B7 bolting materials

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1985-01-01

    An investigation was performed on eleven commonly used lubricants by the nuclear power industry. The investigation included EDS analysis of the lubricants, notched-tensile constant extension rate testing of bolting materials with the lubricants, frictional testing of the lubricants and weight loss testing of a bonded solid film lubricant. The report generally concludes that there is a significant amount of variance in the mechanical properties of common bolting materials; that MoS 2 can hydrolyze to form H 2 S at 100 0 C and cause stress corrosion cracking (SCC) of bolting materials, and that the use of copper-containing lubricants can be potentially detrimental to high strength steels in an aqueous environment. Additionally, the testing of various lubricants disclosed that some lubricants contain potentially detrimental elements (e.g. S, Sb) which can promote SCC of the common bolting materials. One of the most significant findings of this report is the observation that both A193 B7 and A540 B24 bolting materials are susceptible to transgranular stress corrosion cracking in demineralized H 2 O at 280 0 C in notched tensile tests

  18. Finite element model study of the effect of corner rounding on detectability of corner cracks using bolt hole eddy current

    Science.gov (United States)

    Underhill, P. R.; Krause, T. W.

    2017-02-01

    Recent work has shown that the detectability of corner cracks in bolt-holes is compromised when rounding of corners arises, as might occur during bolt-hole removal. Probability of Detection (POD) studies normally require a large number of samples of both fatigue cracks and electric discharge machined notches. In the particular instance of rounding of bolt-hole corners the generation of such a large set of samples representing the full spectrum of potential rounding would be prohibitive. In this paper, the application of Finite Element Method (FEM) modeling is used to supplement the study of detection of cracks forming at the rounded corners of bolt-holes. FEM models show that rounding of the corner of the bolt-hole reduces the size of the response to a corner crack to a greater extent than can be accounted for by loss of crack area. This reduced sensitivity can be ascribed to a lower concentration of eddy currents at the rounded corner surface and greater lift-off of pick-up coils relative to that of a straight-edge corner. A rounding with a radius of 0.4 mm (.016 inch) showed a 20% reduction in the strength of the crack signal. Assuming linearity of the crack signal with crack size, this would suggest an increase in the minimum detectable size by 25%.

  19. Inflorescence Development and the Role of LsFT in Regulating Bolting in Lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Chen, Zijing; Han, Yingyan; Ning, Kang; Ding, Yunyu; Zhao, Wensheng; Yan, Shuangshuang; Luo, Chen; Jiang, Xiaotang; Ge, Danfeng; Liu, Renyi; Wang, Qian; Zhang, Xiaolan

    2017-01-01

    Lettuce ( Lactuca sativa L.) is one of the most important leafy vegetable that is consumed during its vegetative growth. The transition from vegetative to reproductive growth is induced by high temperature, which has significant economic effect on lettuce production. However, the progression of floral transition and the molecular regulation of bolting are largely unknown. Here we morphologically characterized the inflorescence development and functionally analyzed the FLOWERING LOCUS T (LsFT) gene during bolting regulation in lettuce. We described the eight developmental stages during floral transition process. The expression of LsFT was negatively correlated with bolting in different lettuce varieties, and was promoted by heat treatment. Overexpression of LsFT could recover the late-flowering phenotype of ft-2 mutant. Knockdown of LsFT by RNA interference dramatically delayed bolting in lettuce, and failed to respond to high temperature. Therefore, this study dissects the process of inflorescence development and characterizes the role of LsFT in bolting regulation in lettuce.

  20. Probability of detection for bolt hole eddy current in extracted from service aircraft wing structures

    Science.gov (United States)

    Underhill, P. R.; Uemura, C.; Krause, T. W.

    2018-04-01

    Fatigue cracks are prone to develop around fasteners found in multi-layer aluminum structures on aging aircraft. Bolt hole eddy current (BHEC) is used for detection of cracks from within bolt holes after fastener removal. In support of qualification towards a target a90/95 (detect 90% of cracks of depth a, 95% of the time) of 0.76 mm (0.030"), a preliminary probability of detection (POD) study was performed to identify those parameters whose variation may keep a bolt hole inspection from attaining its goal. Parameters that were examined included variability in lift-off due to probe type, out-of-round holes, holes with diameters too large to permit surface-contact of the probe and mechanical damage to the holes, including burrs. The study examined the POD for BHEC of corner cracks in unfinished fastener holes extracted from service material. 68 EDM notches were introduced into two specimens of a horizontal stabilizer from a CC-130 Hercules aircraft. The fastener holes were inspected in the unfinished state, simulating potential inspection conditions, by 7 certified inspectors using a manual BHEC setup with an impedance plane display and also with one inspection conducted utilizing a BHEC automated C-Scan apparatus. While the standard detection limit of 1.27 mm (0.050") was achieved, given the a90/95 of 0.97 mm (0.039"), the target 0.76 mm (0.030") was not achieved. The work highlighted a number of areas where there was insufficient information to complete the qualification. Consequently, a number of recommendations were made. These included; development of a specification for minimum probe requirements; criteria for condition of the hole to be inspected, including out-of-roundness and presence of corrosion pits; statement of range of hole sizes; inspection frequency and data display for analysis.

  1. Thermodynamics of Taub-NUT/bolt black holes in Einstein-Maxwell gravity

    International Nuclear Information System (INIS)

    Dehghani, M.H.; Khodam-Mohammadi, A.

    2006-01-01

    First, we construct the Taub-NUT/bolt solutions of (2k+2)-dimensional Einstein-Maxwell gravity, when all the factor spaces of 2k-dimensional base space B have positive curvature. These solutions depend on two extra parameters, other than the mass and the NUT charge. These are electric charge q and electric potential at infinity V. We investigate the existence of Taub-NUT solutions and find that in addition to the two conditions of uncharged NUT solutions, there exist two extra conditions. These two extra conditions come from the regularity of vector potential at r=N and the fact that the horizon at r=N should be the outer horizon of the NUT charged black hole. We find that the NUT solutions in 2k+2 dimensions have no curvature singularity at r=N, when the 2k-dimensional base space is chosen to be CP 2k . For bolt solutions, there exists an upper limit for the NUT parameter which decreases as the potential parameter increases. Second, we study the thermodynamics of these spacetimes. We compute temperature, entropy, charge, electric potential, action and mass of the black hole solutions, and find that these quantities satisfy the first law of thermodynamics. We perform a stability analysis by computing the heat capacity, and show that the NUT solutions are not thermally stable for even k's, while there exists a stable phase for odd k's, which becomes increasingly narrow with increasing dimensionality and wide with increasing V. We also study the phase behavior of the 4 and 6 dimensional bolt solutions in canonical ensemble and find that these solutions have a stable phase, which becomes smaller as V increases

  2. Application of the cylindrically guided wave technique for bolt and pump shaft inspections

    International Nuclear Information System (INIS)

    Light, G.M.; Ruescher, E.H.; Bloom, E.A.; Joshi, N.R.; Tsai, Y.M.; Liu, S.N.

    1993-01-01

    Elastic wave propagation in a bounded medium significantly differs from that in an unbounded medium. The bounded medium in the form of a cylinder acts like a solid waveguide directing the wave with its geometry. A continuous or a pulsed wave interacts with cylindrical boundaries producing mode-converted signals in addition to the backwall echo. The signals are received at constant time intervals directly proportional to the diameter of a solid cylindrical object such as a bolt or an anchor stud. The Cylindrically Guided Wave Technique (CGWT) makes intelligent use of the mode-converted signals, or trailing pulses, to detect corrosion wastages and cracks in cylindrical objects. (orig.)

  3. Bolted Ribs Analysis for the ITER Vacuum Vessel using Finite Element Submodelling Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Zarzalejos, José María, E-mail: jose.zarzalejos@ext.f4e.europa.eu [External at F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Fernández, Elena; Caixas, Joan; Bayón, Angel [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019, Barcelona (Spain); Polo, Joaquín [Iberdrola Ingeniería y Construcción, Avenida de Manoteras 20, 28050 Madrid (Spain); Guirao, Julio [Numerical Analysis Technologies, S L., Marqués de San Esteban 52, Entlo, 33209 Gijon (Spain); García Cid, Javier [Iberdrola Ingeniería y Construcción, Avenida de Manoteras 20, 28050 Madrid (Spain); Rodríguez, Eduardo [Mechanical Engineering Department EPSIG, University of Oviedo, Gijon (Spain)

    2014-10-15

    Highlights: • The ITER Vacuum Vessel Bolted Ribs assemblies are modelled using Finite Elements. • Finite Element submodelling techniques are used. • Stress results are obtained for all the assemblies and a post-processing is performed. • All the elements of the assemblies are compliant with the regulatory provisions. • Submodelling is a time-efficient solution to verify the structural integrity of this type of structures. - Abstract: The ITER Vacuum Vessel (VV) primary function is to enclose the plasmas produced by the ITER Tokamak. Since it acts as the first radiological barrier of the plasma, it is classified as a class 2 welded box structure, according to RCC-MR 2007. The VV is made of an inner and an outer D-shape, 60 mm-thick double shell connected through thick massive bars (housings) and toroidal and poloidal structural stiffening ribs. In order to provide neutronic shielding to the ex-vessel components, the space between shells is filled with borated steel plates, called In-Wall Shielding (IWS) blocks, and water. In general, these blocks are connected to the IWS ribs which are connected to adjacent housings. The development of a Finite Element model of the ITER VV including all its components in detail is unaffordable from the computational point of view due to the large number of degrees of freedom it would require. This limitation can be overcome by using submodelling techniques to simulate the behaviour of the bolted ribs assemblies. Submodelling is a Finite Element technique which allows getting more accurate results in a given region of a coarse model by generating an independent, finer model of the region under study. In this paper, the methodology and several simulations of the VV bolted ribs assemblies using submodelling techniques are presented. A stress assessment has been performed for the elements involved in the assembly considering possible types of failure and including stress classification and categorization techniques to analyse

  4. Use of the cylindrically guided wave technique for the inspection of stud bolts, valve stems and pump shafts

    International Nuclear Information System (INIS)

    Light, G.M.; Bloom, E.A.; Ruescher, E.H.; Lui, S.N.

    1989-01-01

    Over the last several years, nuclear power plants have expressed concern about failures of bolting, valve stems, and pump shafts. This paper reports on the development of an ultrasonic technique to inspect these components. The authors have successfully demonstrated the cylindrically guided wave technique (CGWT) on a wide range of stud bolts. The CGWT employs zero-degree longitudinal waves constrained to travel within the boundary of the cylindrically shaped components during inspection. Theoretically explained, mode conversion occurs because the ultrasonic wave is guided down the length of the component. These mode-converted signals are dependent upon the diameter of the component under inspection and the longitudinal- and shear-wave velocities of the component material. This technique has also been successfully used on valve stems in the field. The geometry of the valve stem is very similar to that of the stud bolt

  5. Measurement of the Length of Installed Rock Bolt Based on Stress Wave Reflection by Using a Giant Magnetostrictive (GMS) Actuator and a PZT Sensor.

    Science.gov (United States)

    Luo, Mingzhang; Li, Weijie; Wang, Bo; Fu, Qingqing; Song, Gangbing

    2017-02-23

    Rock bolts, as a type of reinforcing element, are widely adopted in underground excavations and civil engineering structures. Given the importance of rock bolts, the research outlined in this paper attempts to develop a portable non-destructive evaluation method for assessing the length of installed rock bolts for inspection purposes. Traditionally, piezoelectric elements or hammer impacts were used to perform non-destructive evaluation of rock bolts. However, such methods suffered from many major issues, such as the weak energy generated and the requirement for permanent installation for piezoelectric elements, and the inconsistency of wave generation for hammer impact. In this paper, we proposed a portable device for the non-destructive evaluation of rock bolt conditions based on a giant magnetostrictive (GMS) actuator. The GMS actuator generates enough energy to ensure multiple reflections of the stress waves along the rock bolt and a lead zirconate titantate (PZT) sensor is used to detect the reflected waves. A new integrated procedure that involves correlation analysis, wavelet denoising, and Hilbert transform was proposed to process the multiple reflection signals to determine the length of an installed rock bolt. The experimental results from a lab test and field tests showed that, by analyzing the instant phase of the periodic reflections of the stress wave generated by the GMS transducer, the length of an embedded rock bolt can be accurately determined.

  6. High-strength bolt-forming of fine-grained aluminum alloy 6061 with a continuous hybrid process

    International Nuclear Information System (INIS)

    Kim, Ji Hun; Hwang, Sun Kwang; Im, Yong-Taek; Son, Il-Heon; Bae, Chul Min

    2012-01-01

    Highlights: ► Fine-grained AA6061-O was produced by a continuous hybrid process. ► It consists of rolling, ECAP, and drawing. ► High-strength bolt was manufactured with the fine-grained AA6061-O. ► The UTS and micro-hardness of the bolt was increased by 50%. ► The route C was better in making a uniform micro-hardness distribution in the bolt. - Abstract: It is well known that the development of a continuous manufacturing process to apply severe plastic deformation (SPD) is a major challenge for industrial usages to improve the mechanical properties of the material through grain refinement. In this study, fine-grained AA6061-O wire was manufactured by a two-pass hybrid process consisting of drawing, equal channel angular pressing and rolling in a continuous manner to investigate the effects of processing routes for two different routes, A and C, on the variation of ultimate tensile strength (UTS) and micro-hardness distribution. The UTS value (185 MPa) of the specimen processed by the two-pass hybrid process with route A was higher than that of 171 MPa obtained from the two-pass wire-drawing process and was equivalent to the level of 184 MPa processed by the three-pass wire-drawing process. The average micro-hardness value (Hv 58.0) obtained from the two-pass hybrid process through route C was the highest among all the cases. According to transmission electron microscopy, the original grain was subdivided and elongated owing to deformation during the processes. The specimen processed by the two-pass hybrid process through route C showed smaller deformation bands and had potentially higher angle grain boundaries compared to the specimen processed by the two-pass wire-drawing process. Finally, the high-strength bolt was manufactured using the fine-grained AA6061-O wire prepared by the continuous hybrid process to check its formability. A ductile fracture at the first thread right above the jaw was observed in the bolt tension test of the manufactured bolt

  7. Fretting fatigue cracking of a center guide bolt supporting the combustion chamber in a heavy-duty gas turbine engine

    Energy Technology Data Exchange (ETDEWEB)

    Neidel, Andreas; Fischer, Boromir; Gaedicke, Tobias [Siemens AG, Energy Sector, Gasturbinenwerk Berlin (Germany). Werkstoffprueflabor

    2018-04-01

    The slotted center guide bolt of the center guide feature of the lower part of the outer shell of an annular combustion chamber was found fractured in a heavy-duty gas turbine engine used for power generation, after approximately 5.500 operating hours. The incident was a one-off event and not a recurring incident. No similar events were reported from the fleet; hence the failure was not considered a field issue. The metallurgical root cause investigation that was ordered to determine the failure mechanism revealed that the incident center guide bolt failed by fretting fatigue cracking, a high cycle fatigue (HCF) phenomenon.

  8. A real-time visual inspection method of fastening bolts in freight car operation

    Science.gov (United States)

    Nan, Guo; Yao, JunEn

    2015-10-01

    A real-time inspection of the key components is necessary for ensuring safe operation of freight car. While traditional inspection depends on the trained human inspectors, which is time-consuming and lower efficient. With the development of machine vision, vision-based inspection methods get more railway on-spot applications. The cross rod end fastening bolts are important components on both sides of the train body that fixing locking plates together with the freight car main structure. In our experiment, we get the images containing fastening bolt components, and accurately locate the locking plate position using a linear Support Vector Machine (SVM) locating model trained with Histograms of Oriented Gradients (HOG) features. Then we extract the straight line segment using the Line Segment Detector (LSD) and encoding them in a range, which constitute a straight line segment dataset. Lastly we determine the locking plate's working state by the linear pattern. The experiment result shows that the localization accurate rate is over 99%, the fault detection rate is over 95%, and the module implementation time is 2f/s. The overall performance can completely meet the practical railway safety assurance application.

  9. Intergranular cracking mechanism in baffle former bolt materials for PWR core internals

    Energy Technology Data Exchange (ETDEWEB)

    Yonezawa, Toshio; Arioka, Koji; Kanasaki, Hiroshi; Fujimoto, Koji [Takasago R and D Center, Mitsubishi Heavy Industries Ltd., Takasago, Hyogo (Japan); Ajiki, Kazuhide [Kobe Shipyard and Machinery, Mitsubishi Heavy Industries Ltd., Kobe, Hyogo (Japan); Matsuoka, Takanori [Nuclear Development Corp., Tokai, Ibaraki (Japan); Urata, Sigeru; Mizuta, Hitoshi [Kansai Electric Power Co., Inc., Osaka (Japan)

    2000-03-01

    In this study, the cause of intergranular cracking in baffle former bolts(BFBs) was estimated from metallurgical and chemical viewpoints based upon the experimental data and information published by EdF. At first, five kinds of possibilities were estimated as the cause of intergranular cracking in BFBs. Five possibilities estimated were (1) mechanical cracking caused by high strain in irradiation hardened austenitic stainless steels, (2) O{sub 2} SCC due to residual oxygen in the bolt stagnant region, (3) caustic SCC due to dry and wet phenomenon, (4) low pH SCC due to oxygen concentration cell, and (5) PWSCC due to radiation induced segregation. In this study each possibility was evaluated by the calculation and some out of pile tests. And also, the cause of the intergranular cracking in BFBs was estimated by the data of the post-irradiation examinations and basic out of pile tests for Type 316CW and Type 347 stainless steels in the authors' previous study. From these evaluation, the intergranular cracking in BFBs seems to be caused by the PWSCC, but not caused by mechanical cracking O{sub 2} SCC, caustic SCC or low pH SCC. (author)

  10. A Noble Approach of Process Automation in Galvanized Nut, Bolt Manufacturing Industry

    Directory of Open Access Journals (Sweden)

    Akash Samanta

    2012-05-01

    Full Text Available Corrosion costs money”, The Columbus battle institute estimates that corrosion costs Americans more than $ 220 billion annually, about 4.3% of the gross natural product [1].Now a days due to increase of pollution, the rate of corrosion is also increasing day-by-day mainly in India, so, to save the steel structures, galvanizing is the best and the simplest solution. Due to this reason galvanizing industries are increasing day-by-day since mid of 1700s.Galvanizing is a controlled metallurgical combination of zinc and steel that can provide a corrosion resistance in a wide variety of environment. In fact, the galvanized metal corrosion resistance factor can be some 70 to 80 times greater that the base metal material. Keeping in mind the importance of this industry, a noble approach of process automation in galvanized nut-bolt  manufacturing plant is presented here as nuts and bolts are the prime ingredient of any structure. In this paper the main objectives of any industry like survival, profit maximization, profit satisfying and sales growth are fulfilled. Furthermore the environmental aspects i.e. pollution control and energy saving are also considered in this paper. The whole automation process is done using programmable logic controller (PLC which has number of unique advantages like being faster, reliable, requires less maintenance and reprogrammable. The whole system has been designed and tested using GE, FANUC PLC.

  11. Analytical design method for a truss-bolt system for reinforcement of fractured coal mine roofs - illustrated with a case study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B.; Yue, Z.Q.; Tham, L.G. [University of Hong Kong, Hong Kong (China). Dept. of Civil Engineering

    2005-02-01

    This paper presents an analytical design method for the truss-bolt system in reinforcing underground fractured rock roofs in coal mines. The analytical design method is based on the mechanical analysis of the fractured rock roof with reinforcement by inclined roof bolts and a horizontal tie-rod. The mechanical analysis for the system includes a non-linear bending model for the laterally inclined roof bolts and three upper and lower bounds. The lateral resistance of the inclined roof bolts in a truss-bolt-supported roadway is examined using classical theory of a non-linear beam in bending. The paper analyses the arching action by lateral behavior of the inclined roof bolts in reinforcing the fractured roof. Based on mechanical models, the design formula concerning the lateral bolt forces, tensions in the tie-rod in the truss system, as well as the reinforcement behavior have been derived. In order to ensure that the roof truss-bolt system reinforces the coal roof effectively, a lower bound of pre-tightening forces must be applied on the tie-rod for stabilizing the fractured roof by arching action. The pre-tightening forces exerted via the tie-rod also cannot be greater than its upper bound, since the excessive tightening force will cause localized failure in the rock near the bolt tail at the abutment of the fractured roof beam. The analytical formulas for both lower and upper bounds for truss pre-tightening forces are put forward in this paper. Furthermore, the paper also presents analytical equations for designing the axial forces and dimensions for bolts in this kind of system.

  12. Leveraging External Sources of Innovation

    DEFF Research Database (Denmark)

    West, Joel; Bogers, Marcel

    2014-01-01

    , it suggests a four-phase model in which a linear process—(1) obtaining, (2) integrating, and (3) commercializing external innovations—is combined with (4) interaction between the firm and its collaborators. This model is used to classify papers taken from the top 25 innovation journals, complemented by highly...... cited work beyond those journals. A review of 291 open innovation-related publications from these sources shows that the majority of these articles indeed address elements of this inbound open innovation process model. Specifically, it finds that researchers have front-loaded their examination...... external innovations create value rather than how firms capture value from those innovations. Finally, the interaction phase considers both feedback for the linear process and reciprocal innovation processes such as cocreation, network collaboration, and community innovation. This review and synthesis...

  13. Regulating multiple externalities

    DEFF Research Database (Denmark)

    Waldo, Staffan; Jensen, Frank; Nielsen, Max

    2016-01-01

    Open access is a well-known externality problem in fisheries causing excess capacity and overfishing. Due to global warming, externality problems from CO2 emissions have gained increased interest. With two externality problems, a first-best optimum can be achieved by using two regulatory instrume......Open access is a well-known externality problem in fisheries causing excess capacity and overfishing. Due to global warming, externality problems from CO2 emissions have gained increased interest. With two externality problems, a first-best optimum can be achieved by using two regulatory...

  14. Effect of Temperature and Viscoelastic Creep on the Clamp-Up Load in Hybrid Composite/Metal Bolted Joints

    Science.gov (United States)

    2009-08-17

    Glaser. Also acknowledged is the assistance of Dr. Jose Daniel Diniz Melo, chair of the Department of Engineering Materials, Universidade Federal do Rio...supervision of Dr. Jose Daniel Diniz Melo. Figure 2.1 shows the 8mm cubic CTE specimens used in these experiments. They were machined to meet the

  15. Turning caring into business: the nuts and bolts of starting a private-duty home care business.

    Science.gov (United States)

    Smith, Cheryl

    2007-10-01

    As baby boomers age and home care grows in popularity as an alternative to institutionalized care, opportunities abound for entrepreneurs to meet the demand through professional private-duty businesses. This article examines the nuts and bolts of launching and operating a successful private-duty agency.

  16. Application of FE-analysis in Design and Verification of Bolted Joints according to VDI 2230 at CERN

    CERN Document Server

    AUTHOR|(CDS)2225945; Dassa, Luca; Welo, Torgeir

    This thesis investigates how finite element analysis (FEA) can be used to simplify and improve analysis of bolted joints according to the guideline VDI 2230. Some aspects of how FEA can be applied to aid design and verification of bolted joints are given in the guideline, but not in a streamlined way that makes it simple and efficient to apply. The scope of this thesis is to clarify how FEA and VDI 2230 can be combined in analysis of bolted joints, and to present a streamlined workflow. The goal is to lower the threshold for carrying out such combined analysis. The resulting benefits are improved analysis validity and quality, and improved analysis efficiency. A case from the engineering department at CERN, where FEA has been used in analysis of bolted joints is used as basis to identify challenges in combining FEA and VDI 2230. This illustrates the need for a streamlined analysis strategy and well described workflow. The case in question is the Helium vessel (pressure vessel) for the DQW Crab Cavities, whi...

  17. Efficiency of low versus high airline pressure in stunning cattle with a pneumatically powered penetrating captive bolt gun.

    Science.gov (United States)

    Oliveira, Steffan Edward Octávio; Gregory, Neville George; Dalla Costa, Filipe Antonio; Gibson, Troy John; Paranhos da Costa, Mateus José Rodrigues

    2017-08-01

    The efficiency of stunning cattle was assessed in 443 animals (304 pure Zebu and 139 crossbred cattle), being mainly mature bulls and cows. Cattle were stunned using a Jarvis pneumatically powered penetrating captive bolt gun operating with low (160-175psi, N=82) and high (190psi, N=363) airline pressure, which was within the manufactures specifications. Signs of brain function and the position of the shots on the heads were recorded after stunning. Velocity of the captive bolt and its physical parameters were calculated. Cattle shot with low pressures showed more rhythmic respiration (27 vs. 8%, P<0.001), less tongue protrusion (4 vs. 12%, P=0.03) and less masseter relaxation (22 vs. 48%, P<0.001). There was an increased frequency of shots in the ideal position when cattle were shot with the low compared to high airline pressures (15.3 vs. 3.1%). Bolt velocity and its physical parameters were significantly (P<0.01) higher when using high pressure. Airline pressures below 190psi are inappropriate when shooting adult Zebu beef cattle with pneumatically powered penetrating captive bolt guns. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Upon bolting the GTR1 and GTR2 transporters mediate transport of glucosinolates to the inflorescence rather than roots

    DEFF Research Database (Denmark)

    Andersen, Tonni Grube; Halkier, Barbara Ann

    2014-01-01

    We recently described the glucosinolate transporters GTR1 and GTR2 as actively contributing to the establishment of tissue-specific distribution of the defense compounds glucosinolates in vegetative Arabidopsis plants. Upon bolting and thereby development of the inflorescence and initiation of seed...

  19. ExternE National Implementation Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pingoud, K; Maelkki, H; Wihersaari, M; Pirilae, P [VTT Energy, Espoo (Finland); Hongisto, M [Imatran Voima Oy, Vantaa (Finland); Siitonen, S [Ekono Energy Ltd, Espoo (Finland); Johansson, M [Finnish Environment Institute, Helsinki (Finland)

    1999-07-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  20. ExternE National Implementation Finland

    International Nuclear Information System (INIS)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P.; Hongisto, M.; Siitonen, S.; Johansson, M.

    1999-01-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  1. ExternE National Implementation Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P. [VTT Energy, Espoo (Finland); Hongisto, M. [Imatran Voima Oy, Vantaa (Finland); Siitonen, S. [Ekono Energy Ltd, Espoo (Finland); Johansson, M. [Finnish Environment Institute, Helsinki (Finland)

    1999-07-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  2. External Otitis (Swimmer's Ear)

    Science.gov (United States)

    ... otitis. Fungal external otitis (otomycosis), typically caused by Aspergillus niger or Candida albicans, is less common. Boils are ... in the ear. Fungal external otitis caused by Aspergillus niger usually causes grayish black or yellow dots (called ...

  3. ExternE: Externalities of energy Vol. 2. Methodology

    International Nuclear Information System (INIS)

    Berry, J.; Holland, M.; Watkiss, P.

    1995-01-01

    This report describes the methodology used by the ExternE Project of the European Commission (DGXII) JOULE Programme for assessment of the external costs of energy. It is one of a series of reports describing analysis of nuclear, fossil and renewable fuel cycles for assessment of the externalities associated with electricity generation. Part I of the report deals with analysis of impacts, and Part II with the economic valuation of those impacts. Analysis is conducted on a marginal basis, to allow the effect of an incremental investment in a given technology to be quantified. Attention has been paid to the specificity of results with respect to the location of fuel cycle activities, the precise technologies used, and the type and source of fuel. The main advantages of this detailed approach are as follows: It takes full and proper account of the variability of impacts that might result from different power projects; It is more transparent than analysis based on hypothetically 'representative' cases for each of the different fuel cycles; It provides a framework for consistent comparison between fuel cycles. A wide variety of impacts have been considered. These include the effects of air pollution on the natural and human environment, consequences of accidents in the workplace, impacts of noise and visual intrusion on amenity, and the effects of climate change arising from the release of greenhouse gases. Wherever possible we have used the 'impact pathway' or 'damage function' approach to follow the analysis from identification of burdens (e.g. emissions) through to impact assessment and then valuation in monetary terms. This has required a detailed knowledge of the technologies involved, pollutant dispersion, analysis of effects on human and environmental health, and economics. In view of this the project brought together a multi-disciplinary team with experts from many European countries and the USA. The spatial and temporal ranges considered in the analysis are

  4. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  5. Use of a Non-Penetrating Captive Bolt for Euthanasia of Neonate Goats

    Directory of Open Access Journals (Sweden)

    Andrew Grist

    2018-04-01

    Full Text Available A non-penetrating captive bolt device, powered by a 1 grain 0.22″ cartridge delivering a calculated kinetic energy of 47 Joules was tested as a euthanasia method on 200 neonate goats (Capra aegagrus hircus of mean dead weight = 4.425 kg (SD (Standard deviation ± 0.4632, to assess effectiveness and shot position. Evaluation of the method was conducted using behavioural indicators of brain dysfunction followed by post mortem examination of the heads. Once correct shot position had been established, 100% of 158 kids (95% confidence interval 97.5% to 100% were successfully stunned/killed with a shot positioned on the midline, between the ears, with the chin tucked into the neck. The use of the Accles and Shelvoke CASH Small Animal Tool can therefore be recommended for the euthanasia of neonate goats with a 1 grain cartridge and a specific shooting position.

  6. Fractures in high-strength bolts due to hydrogen induced stress corrosion. Causes and corrective actions

    International Nuclear Information System (INIS)

    Hoche, Holger; Oechsner, Matthias

    2017-01-01

    Delayed brittle fractures of high-strength bolts of the strength class 10.9 are presented, taking the example of three damage cases. The respective damage mechanisms could be attributed to hydrogen induced stress corrosion which was caused, in turn, by hydrogen absorption during operation. The examples were chosen with a particular focus on the material condition's susceptibility which explains the cause for the occurrence of the damage mechanism. However, in only one of the three cases the susceptibility was evident and could be explained by violations of normative specifications and an unfavorable material choice. Whereas in the two other examples, only slight or no deviations from the standards and/or regulations could be found. The influencing parameters that caused the damage, those that further promoted the damage, as well as possible corrective actions are discussed taking into account the three exemplary damage cases.

  7. Optimally analyzing and implementing of bolt fittings in steel structure based on ANSYS

    Science.gov (United States)

    Han, Na; Song, Shuangyang; Cui, Yan; Wu, Yongchun

    2018-03-01

    ANSYS simulation software for its excellent performance become outstanding one in Computer-aided Engineering (CAE) family, it is committed to the innovation of engineering simulation to help users to shorten the design process. First, a typical procedure to implement CAE was design. The framework of structural numerical analysis on ANSYS Technology was proposed. Then, A optimally analyzing and implementing of bolt fittings in beam-column join of steel structure was implemented by ANSYS, which was display the cloud chart of XY-shear stress, the cloud chart of YZ-shear stress and the cloud chart of Y component of stress. Finally, ANSYS software simulating results was compared with the measured results by the experiment. The result of ANSYS simulating and analyzing is reliable, efficient and optical. In above process, a structural performance's numerical simulating and analyzing model were explored for engineering enterprises' practice.

  8. [Suicide by double bolt gunshot wound to the head: case report and review of the literature].

    Science.gov (United States)

    Grellner, W; Buhmann, D; Wilske, J

    2000-01-01

    Suicidal gunshot wounds from a livestock stunner with infliction of two shots against the head are extremely rare events. A case with these characteristics is presented and the corresponding literature is reviewed. A 61-year-old butcher was found dead with two entry wounds of the forehead on the right side and in the centre being typical for captive bolt pistols (symmetrically localized powder burns). The issues of the sequence of shots and the capacity of action are discussed on the basis of morphological findings and pathophysiological considerations. A literature review revealed only 4 case reports with double gunshot wounds of the skull caused by "humane killers" (Tovo 1956, Wolff and Laufer 1965, Schiermeyer 1973, Pollak 1977).

  9. Resolution of Generic Safety Issue 29: Bolting degradation or failure in nuclear power plants

    International Nuclear Information System (INIS)

    Johnson, R.E.

    1990-06-01

    This report describes the US Nuclear Regulatory Commission's (NRC's) Generic Safety Issue 29, ''Bolting Degradation or Failure in Nuclear Power Plants,'' including the bases for establishing the issue and its historical highlights. The report also describes the activities of the Atomic Industrial Forum (AIF) relevant to this issue, including its cooperation with the Materials Properties Council (MPC) to organize a task group to help resolve the issue. The Electric Power Research Institute, supported by the AIF/MPC task group, prepared and issued a two-volume document that provides, in part, the technical basis for resolving Generic Safety Issue 29. This report presents the NRC's review and evaluation of the two-volume document and NRC's conclusion that this document, in conjunction with other information from both industry and NRC, provides the bases for resolving this issue

  10. Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor.

    Science.gov (United States)

    Chang, Kuo Tsi

    2003-08-01

    This paper suggests a parallel resistor to reduce DC time constant and DC response time of the transient response, induced immediately after an AC voltage connected to a bolt-clamped Langevin transducer (BLT) is switched off. An equivalent circuit is first expressed. Then, an open-circuit transient response at the terminals induced by initial states is derived and measured, and thus parameters for losses of the BLT device are estimated by DC and AC time constants of the transient response. Moreover, a driving and measuring system is designed to determine transient response and steady-state responses of the BLT device, and a parallel resistor is connected to the BLT device to reduce the DC time constant. Experimental results indicate that the DC time constant greatly exceeds the AC time constant without the parallel resistor, and greatly decreases from 42 to 1 ms by a 100-kOmega parallel resistor.

  11. INFORMATION FOR USERS OF NUTS, BOLTS, SCREWS, NAILS AND RIVETS (SCEM GROUP 47)

    CERN Multimedia

    Logistics Group

    2002-01-01

    We should like to remind users that, since the closure of the self-service stores, nuts, bolts, screws, nails and rivets (Group 47 of the Stores Catalogue) can be obtained, in smaller packages than via EDH, from the 'Emergency Counter' in the Central Stores (Building 73, R-002) upon presentation of a duly completed hard-copy Materials Request form. The 'Emergency Counter' is open Mondays to Fridays from 7.30 a.m. to 11.50 a.m. and from 1.00 p.m. to 4.20 p.m. Information concerning the available packages can be found under the appropriate SCEM reference number in the Stores Catalogue. Logistics Group SPL Division

  12. Development of an eddy current inspection technique for sleeved engine disk bolt holes

    International Nuclear Information System (INIS)

    Palanisamy, R.; Lakin, K.M.

    1983-01-01

    Recent research programs have concentrated mainly on developing techniques to characterize surface breaking cracks and very little has been done towards characterizing subsurface flaws in conducting materials. Presented in this paper are the results of some initial theoretical work aimed at the development of a reliable eddy current technique to detect and characterize defects in engine disk bolt holes under a 0.05'' stainless steel sleeve. The change in impedance of an absolute eddy current coil with and without ferrite core, and the distribution of eddy currents around a second layer crack with and without a thin insulating film between the two conducting layers have been predicted numerically. The overall system development goals and methods to accomplish them are outlined briefly

  13. External wave-launcher study. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    The rationale for liquid dielectrically-loaded external wave-guide launchers is discussed. The arguments are strongly indicative that a liquid dielectric-filled waveguide system could be a practical technique for launching ICRH power into a fusion reactor. A detailed summary of the work performed in the study is presented

  14. Evaluation on the structural soundness of the package with the lid bolted for subsurface disposal by finite element method

    International Nuclear Information System (INIS)

    Ito, Chihiro

    2011-01-01

    The structural analysis of the disposal package for low-level radioactive wastes with relatively high activities (called L1 waste in Japan) were performed against normal and hypothetical conditions. As a normal condition the external load due to lifting, stacking of the package and filling the space of disposal pit with mortar or something were considered. Drop incident during handling and pressure due to some external force were taken up as hypothetical conditions. Using finite element code ABAQUS and three dimensional finite element model, structural analyses were carried out for the normal conditions. The results show that the maximum stresses occurred at the package due to the loads above mentioned were far less than the yield strength for all conditions. Therefore, it is confirmed that the disposal package keeps its integrity against the normal conditions. Analyses for load cases of 8 m drop onto the reinforced concrete slab were performed by using finite element code LS-DYNA. The results show that the strains at the impact zone of the package exceeded the fracture strain of the material and the opening of the lid at the vicinity on the impact zone was observed but the damaged area was limited in the vicinity of impact zone. As a maximum external pressure, 4 MPa was applied to the surface of the packages which were piled up in four layered in the disposal tunnel. According to the results of analyses by ABAQUS code the maximum strain occurred at the contact surfaces between lid and body of the top package. However, the package stays in sound because the plastic zone was so small and the value of the maximum strain was less than the fracture strain of the materials. (author)

  15. Bottom loaded filter for radioactive liquid

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1980-01-01

    A specification is given for a bottom loaded filter assembly for filtering radioactive liquids through a replaceable cartridge filter, which includes a lead-filled jacket enveloping a housing having a chamber therein for the filter cartridge. A track arrangement carries a hatch for sealing the chamber. A spacer plug supports the cartridge within guide means associated with the inlet conduit in the chamber. The plug and cartridge drop out of the chamber when the hatch is unbolted and moved laterally of the chamber along the track. During cartridge replacement a new plug and cartridge are supported in the guide means by a spacer bar inserted across the track means under the chamber. The hatch is then slid under the chamber and bolted to a flange on the housing, engaging an O-ring to seal the chamber. (author)

  16. EDF studies on PWR vessel internal loading

    International Nuclear Information System (INIS)

    Bellet, S.; Vallat, S.

    1998-01-01

    EDF has undertaken some mechanics and thermal-hydraulics studies with the objective of mastering plant phenomena today and in order to numerically predict the behaviour of vessel internals on units planned for the future. From some justifications already underway after in operation incidents (wear and drop time of RCCA rods, fuel deflection, adapter cracks, baffle bolt cracks) we intend to control reactor vessel flows and mechanical behaviour of internal structures. During normal operation, thermal-hydraulic is the main load of vessel internals. The current approach consists of acquiring the capacity to link different calculations, taking care that codes are qualified for physical phenomena and complex 3D geometries. For baffle assembly, a more simple model of this structure has been used to treat the physical phenomena linked to the LOCA transient. Results are encouraging mainly due to code capacity progression (resolution and models), which allows more and more complex physical phenomena to be treated, like turbulence flow and LOCA. (author)

  17. Bottom loaded filter for radioactive liquids

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1980-01-01

    A bottom loaded filter assembly for filtering radioactive liquids through a replaceable cartridge filter is disclosed. The filter assembly includes a lead-filled jacket enveloping a housing having a chamber therein for the filter cartridge. A track arrangement carries a hatch for sealing the chamber. A spacer plug supports the cartridge within guide means associated with the inlet conduit in the chamber. The plug and cartridge drop out of the chamber when the hatch is unbolted and move laterally of the chamber. During cartridge replacement, a new plug and cartridge are supported in the guide means by a spacer bar inserted across the track means under the chamber. The hatch is then slid under the chamber and bolted to the vessel, engaging an o-ring to seal the chamber

  18. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  19. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    International Nuclear Information System (INIS)

    Tesfa, B; Horler, G; Thobiani, F Al; Gu, F; Ball, A D

    2012-01-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. 1. Sense changes in the clamping force of the joint and report this fact. 2. Provide compatibility with the large dynamic range of clamping force. 3. Satisfy the limitations in terms of physical size. 4. Provide the means to electronically interface with the washer. 5. Provide a means of powering the washer in situ. 6. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show

  20. Resolution of Surveillance Report No. PAD-BDW-95-004 for suspect bolts installed in the 105 KW roof addition structure

    International Nuclear Information System (INIS)

    Frier, W.A.

    1995-01-01

    A DOE RL surveillance determined that a test report (WHC-SD-NR-TRP-020) was less than adequate. As a result, WHC removed nine of the previous in-situ tested A325 suspect bolts and contracted with Koon-Hall Testing Corporation to perform hardness and tensile testing and chemical composition analysis of the removed bolts. WHC also contracted with ADVENT Engineering, Inc., to perform an evaluation of the Koon-Hall test results and to respond to the concerns identified in the DOE RL surveillance. The Koon-Hall Laboratory test results and the assessments strongly support the conclusion that the suspect bolts are indeed the equivalent of A325 high-strength, Type-1 bolts and have been properly heat-treated

  1. ExternE: Externalities of energy Vol. 1. Summary

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1995-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase 1 was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes is underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  2. Externalities of fuel cycles 'ExternE' project. Summary report

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1994-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase I was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes are underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  3. Non-linear finite element modelling and analysis of the effect of gasket creep-relaxation on circular bolted flange connections

    International Nuclear Information System (INIS)

    Luyt, P.C.B.; Theron, N.J.; Pietra, F.

    2017-01-01

    It is well known that gasket creep-relaxation results in a reduction of contact pressure between the surface of a gasket and the face of a flange over an extended period of time. This reduction may result in the subsequent failure of the circular bolted flange connection due to leakage. In this paper a pair of flat and raised face integral flanges, PN 10 DN 50 (in accordance with the European EN 1092-1 standard), with non-asbestos compressed fibre ring gaskets with aramid and a nitrile rubber binder were considered. Finite element modelling and analyses were done, for both the circular bolted flange configurations, during the seating condition. The results of the finite element analyses were experimentally validated. It was found that the number of bolt tightening increments as well as the time between the bolt tightening increments had a significant impact on the effect which gasket creep-relaxation had after the seating condition. An increase in either the number of bolting increments or the time between the bolting increments will reduce the effect which gasket creep-relaxation has once the bolts had been fastened. Based on these results it is possible to develop an optimisation scheme to minimize the effect which gasket creep-relaxation has on the contact pressure between the face of the flange and the gasket, after seating, by either increasing or decreasing the number of bolt tightening increments or the time between the bolt tightening increments. - Highlights: • Number of bolt tightening increments and time between bolt tightening increments had significant impact on effect of gasket creep-relaxation after the seating condition. • Impact of gasket creep-relaxation during seating and operating phases investigated by means of finite element analysis and experimentally verified. • Possible to develop optimisation scheme to minimize effect ofh gasket creep-relaxation on contact pressure between flange face and gasket. • Knowing the contact pressure is

  4. The EPR-a comprehensive design concept against external events

    International Nuclear Information System (INIS)

    Stoll, U.; Waas, U.

    2006-01-01

    The main objective of design provisions against external hazards is to ensure that the safety functions required to bring the plant to safe shutdown are not inadmissibly affected by any external hazards that might be postulated for the intended site of the plant. In the design of the European Pressurized Water Reactor (EPR) particular attention was paid to external hazards such as earthquake, airplane crash, and explosion pressure wave. The standard EPR covers a large range of possible site conditions, the design earthquake enveloping safe shutdown earthquakes (SSE) to be expected for potential sites. The loads for the design basis airplane crash and - if required - for the design extension airplane crash as well as for external Explosion Pressure Wave are defined depending on site specific requirements. Protection against other external load cases such as extreme winds and external flooding is also included in the standard design

  5. External radiation surveillance

    International Nuclear Information System (INIS)

    Antonio, E.J.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site

  6. External radiation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site.

  7. SCC life estimation based on cracks initiated from the corrosion pits of bolting material SCM435 used in steam turbine

    International Nuclear Information System (INIS)

    Itoh, Hitomi; Ochi, Mayumi; Fujiwara, Isao; Momoo, Takashi

    2003-01-01

    Life estimation was performed for the stress corrosion cracking (SCC) that occurs in deaerated and wet hot pure steam at the bottoms of the threads of bolts made of SCM435 (equivalent to AISI 4137) used in steam turbine. SCC is believed to occur when corrosion pits are formed and grow to critical size, after which SCC is initiated and cracks propagate until the critical fracture toughness value is reached. Calculations were performed using laboratory and field data. The results showed that, for a 40mm diameter bolt with 0.2% offset strength of 820MPa, the critical crack depth for straight-front cracks was 5.4mm. The SCC life depends on the lubricant used; the SCC life estimated from this value is approximately 70,000 hours when graphite is used as a lubricant. (author)

  8. Structural design of an in-line bolted joint for the space shuttle solid rocket motor case segments

    Science.gov (United States)

    Dorsey, John T.; Stein, Peter A.; Bush, Harold G.

    1987-01-01

    Results of a structural design study of an in-line bolted joint concept which can be used to assemble Space Shuttle Solid Rocket Motor (SRM) case segments are presented. Numerous parametric studies are performed to characterize the in-line bolted joint behavior as major design variables are altered, with the primary objective always being to keep the inside of the joint (where the O-rings are located) closed during the SRM firing. The resulting design has 180 1-inch studs, an eccentricity of -0.5 inch, a flange thickness of 3/4 inch, a bearing plate thickness of 1/4 inch, and the studs are subjected to a preload which is 70% of ultimate. The mass penalty per case segment joint for the in-line design is 346 lbm more than the weight penalty for the proposed capture tang fix.

  9. LCM-seq reveals the crucial role of LsSOC1 in heat-promoted bolting of lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Chen, Zijing; Zhao, Wensheng; Ge, Danfeng; Han, Yingyan; Ning, Kang; Luo, Chen; Wang, Shenglin; Liu, Renyi; Zhang, Xiaolan; Wang, Qian

    2018-05-17

    Lettuce (Lactuca sativa L.) is one of the most economically important vegetables. The floral transition in lettuce is accelerated under high temperatures, which can significantly decrease yields. However, the molecular mechanism underlying the floral tranition in lettuce is poorly known. Using laser capture microdissection coupled with RNA sequencing, we isolated shoot apical meristem cells from the bolting-sensitive lettuce line S39 at four critical stages of development. Subsequently, we screened specifically for the flowering-related gene LsSOC1 during the floral transition through comparative transcriptomic analysis. Molecular biology, developmental biology, and biochemical tools were combined to investigate the biological function of LsSOC1 in lettuce. LsSOC1 knockdown by RNA interference resulted in a significant delay in the timing of bolting and insensitivity to high temperature, which indicated that LsSOC1 functions as an activator during heat-promoted bolting in lettuce. We determined that two heat-shock transcription factors, HsfA1e and HsfA4c, bound to the promoter of LsSOC1 to confirm that LsSOC1 played an important role in heat-promoted bolting. This study indicates that LsSOC1 plays a crucial role in the heat-promoted bolting process in lettuce. Further investigation of LsSOC1 may be useful for clarification of the bolting mechanism in lettuce. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Galvanic corrosion study of aluminium alloy plates mounted to stainless and mild steel bolts by accelerated exposure test

    OpenAIRE

    MREMA, Emmanuel; ITOH, Yoshito; KANEKO, Akira; HIROHATA, Mikihito

    2016-01-01

    Despite the fact that aluminium alloy members have a proven durability over stainless steel members, their joint fasteners like bolts, nuts and washers are drawn from steel material due to aluminium alloy inferior mechanical properties. Bare contact between aluminium alloy members and stainless steel fasteners results to galvanic corrosion of aluminium alloy members. A corrosion behaviour study was carried out on different aluminium alloy types with different surface treatments mounted to sta...

  11. Ultrasonic Detection of Small Crack in Studs[Bolts] by Time Difference of Thread Signals(TDTS)

    International Nuclear Information System (INIS)

    Suh, D. M.; Park, D. Y.; Kim, C. K.

    1990-01-01

    It is difficult to detect such flaws as stress - corrosion cracking or corrosion wastage(loss of bolt diameter) in the threads. In many cases the critical size of a flaw is very small(1-2 mm order). This paper describes how it is possible to discriminate small flaw indications in threads using the time difference or thread signals(TDTS) by a signal-conditioning technique

  12. ExternE: Externalities of energy Vol. 5. Nuclear

    International Nuclear Information System (INIS)

    Dreicer, M.; Tort, V.; Manen, P.

    1995-01-01

    Since the early 1970s, there has been increased interest in the environmental impacts that are caused by the generation of electricity. The comparative risk assessment studies at that time used mainly deaths and injuries as impact indicators. By the end of the 1980s studies changed to the assessment of the costs imposed on society and the environment that were not included in the market price of the energy produced, the so-called external costs. The preliminary studies that were published set the conceptual basis, grounded in neo-classical economics, for the valuation of the health and environmental impacts that could be assessed. As a consequence of the many questions raised by the methodologies employed by these early studies, Directorate General XII (DG XII) of the Commission of the European Communities established a collaborative research programme with the United States Department of Energy to identify an appropriate methodology for this type of work. Following the completion of this collaboration, the DG XII programme has continued as the ExternE project. The main objective of the work carried out at CEPN was to develop an impact pathway methodology for the nuclear fuel cycle that would be consistent with the methodologies developed for other fuel cycles, without loosing the nuclear-specific techniques required for a proper evaluation. In this way, comparisons between the different fuel cycles would be possible. This report presents the methodology and demonstration of the results in the context of the French nuclear fuel cycle. The United States team at Oak Ridge National Laboratory has previously issued a draft report on the results of their assessment. The French fuel cycle was broken down into 8 separate stages. Reference sites and 1990s technology were chosen to represent the total nuclear fuel cycle, as it exists today. In addition, the transportation of material between the sites was considered. The facilities are assessed for routine operation, except

  13. An impedance-based approach for detection and quantification of damage in cracked plates and loose bolts in bridge structures

    Science.gov (United States)

    Rabiei, Masoud; Sheldon, Jeremy; Palmer, Carl

    2012-04-01

    The applicability of Electro-Mechanical Impedance (EMI) approach to damage detection, localization and quantification in a mobile bridge structure is investigated in this paper. The developments in this paper focus on assessing the health of Armored Vehicle Launched Bridges (AVLBs). Specifically, two key failure mechanisms of the AVLB to be monitored were fatigue crack growth and damaged (loose) rivets (bolts) were identified. It was shown through experiment that bolt damage (defined here as different torque levels applied to bolts) can be detected, quantified and located using a network of lead zirconate titanate (PZT) transducers distributed on the structure. It was also shown that cracks of various sizes can be detected and quantified using the EMI approach. The experiments were performed on smaller laboratory specimens as well as full size bridge-like components that were built as part of this research. The effects of various parameters such as transducer type and size on the performance of the proposed health assessment approach were also investigated.

  14. Rate of driving a ventilation tunnel by means of the GPK heading machine using roof bolting and steel supports. [USSR

    Energy Technology Data Exchange (ETDEWEB)

    Cheremnov, V.I.; Kruglyak, A.S.; Miroshnikova, L.A.; Sharov, V.N.

    1983-05-01

    The paper discusses a method for strata control during mine drivage tested in the im. Voroshilov coal mine in 1982. A ventilation tunnel with a crosscut of 16.4 m/sup 2/ was driven in coal with compression strength coefficient from 0.8 to 1.0, argillites and aleurites in the floor and the roof with compression strength coefficient from 4 to 6. Mining depth was 150 m, water influx was low. The tunnel was driven by means of the GPK heading machine with a 1PNB-2 loader. The AMK support system which consisted of arched steel supports, steel beams for joining steel arches and of roof bolts was used. Arched supports were installed each 0.8 m. The roof between the arches was supported by a system of roof bolts and junction beams. Support design is shown in a scheme. Increasing support spacing to 0.8 m (instead of 0.5 m) and roof bolting permitted drivage rate to be increased and steel consumption to be significantly reduced (by 244 kg/m). (3 refs.)

  15. Study of failure mechanism of double-lap joints of steel to FRP by bolt and resin

    Directory of Open Access Journals (Sweden)

    Amir Hossein Zakeri

    2017-05-01

    Full Text Available In this study, the behavior of joints in two sides of steel coat which are screwed to the composite plate, and joints of two sides of compound steel coat (bolted and bonded to the composite plate has been studied. In the standards, distance of mechanical bolts from the edges and the distance of mechanical bolts from each other have been discussed. Different distances in the range of the standards determined for the distance of screws from edges and screws from each other. In this paper, the screw joints and the combined joints with different terminal distances for screws from the edges are modeled and studied. The results showed the basic effects of the terminal distance of the screw from the connection edges on the resistance and mechanism of break of screw joints. In combined joints, the terminal distance of the screw had trivial effects in the resistance and mechanism of joint break. In addition, overlap length of the connection elements on increase of joint resistance analyzed and studied. To do so, a combined joint with configuration of two steel plates and one CFRP/GFRP composite plates which were joined by two screws and adhesive layers with different overlap were modeled. The results showed the direct relationship between increase of overlap length and increase in resistance of the joint. Finally, a design guide to be used in practice was proposed.

  16. Estimation of the thermal neutron flux in a PET cyclotron room via radioactive analysis of the bolts of a wall socket in the room

    International Nuclear Information System (INIS)

    Ogata, Y.; Ishigure, N.; Mochizuki, S.; Ito, K.; Hatano, K.; Abe, J.; Miyahara, H.; Masumoto, K.; Nakamura, H.; Matsumura, H.

    2008-01-01

    Full text: Since positron emission nuclides for PET (Positron Emission Tomography) have short half-lives, they are mainly produced by on-site cyclotrons. Significant amounts of neutrons are generated together with the operating of the cyclotron, and then materials in the room are activated. To quantify the neutron flux density will lead the prediction of the extent of the activation. We tried to estimate the neutron flux of the room via the radioactive analysis of bolts in the room. The cyclotron (Cypris HM-18, Sumitomo Heavy Industry) is able to accelerate protons and deuterons up to 18 and 10 MeV, respectively. The routine charge current is 20μA. The cyclotron is housed in a room with 1 m thickness concrete wall. A couple of bolts of a wall socket were removed to investigate the components and the radioactivities, which were analyzed by fluorescent X-ray spectroscopy and by gamma-ray spectroscopy, respectively. We compared the neutron flux estimated by the bolts analysis with the results measured by the gold foil activation method. The weight sum of the bolts was 1.257 g. They were made of nickel plated brass, and predominantly consisted of Cu (63%) and Zn (34%). Four nuclides, 69m Zn, 65 Zn, 64 Cu, and 60 Co, were detected in the bolts. The activity of 64 Cu half-life of 12.7 h, led the last few days history of neutron flux, and the activity of 65 Zn, 244 d, led the last few years history. The analysis of the bolts activity estimated the thermal neutron flux at 4∼6x10 5 cm -2 s -1 . This figure agreed with the value, 6∼9x10 5 cm -2 s -1 , computed from the activated gold foil near the bolts. Bolts are quite generally installed in such a room. Therefore, the radioactive analysis of the bolts leads convenient and effective estimation of neutron flux there. Consequently, the radioactive analysis of the bolts in the cyclotron room allowed us to estimate the neutron flux in the room. (author)

  17. Element Load Data Processor (ELDAP) Users Manual

    Science.gov (United States)

    Ramsey, John K., Jr.; Ramsey, John K., Sr.

    2015-01-01

    Often, the shear and tensile forces and moments are extracted from finite element analyses to be used in off-line calculations for evaluating the integrity of structural connections involving bolts, rivets, and welds. Usually the maximum forces and moments are desired for use in the calculations. In situations where there are numerous structural connections of interest for numerous load cases, the effort in finding the true maximum force and/or moment combinations among all fasteners and welds and load cases becomes difficult. The Element Load Data Processor (ELDAP) software described herein makes this effort manageable. This software eliminates the possibility of overlooking the worst-case forces and moments that could result in erroneous positive margins of safety and/or selecting inconsistent combinations of forces and moments resulting in false negative margins of safety. In addition to forces and moments, any scalar quantity output in a PATRAN report file may be evaluated with this software. This software was originally written to fill an urgent need during the structural analysis of the Ares I-X Interstage segment. As such, this software was coded in a straightforward manner with no effort made to optimize or minimize code or to develop a graphical user interface.

  18. Beam loading

    OpenAIRE

    Boussard, Daniel

    1987-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superco...

  19. Determination of anatomic landmarks for optimal placement in captive-bolt euthanasia of goats.

    Science.gov (United States)

    Plummer, Paul J; Shearer, Jan K; Kleinhenz, Katie E; Shearer, Leslie C

    2018-03-01

    OBJECTIVE To determine the optimal anatomic site and directional aim of a penetrating captive bolt (PCB) for euthanasia of goats. SAMPLE 8 skulls from horned and polled goat cadavers and 10 anesthetized horned and polled goats scheduled to be euthanized at the end of a teaching laboratory. PROCEDURES Sagittal sections of cadaver skulls from 8 horned and polled goats were used to determine the ideal anatomic site and aiming of a PCB to maximize damage to the midbrain region of the brainstem for euthanasia. Anatomic sites for ideal placement and directional aiming were confirmed by use of 10 anesthetized horned and polled goats. RESULTS Clinical observation and postmortem examination of the sagittal sections of skulls from the 10 anesthetized goats that were euthanized confirmed that perpendicular placement and firing of a PCB at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear, resulted in consistent disruption of the midbrain and thalamus in all goats. Immediate cessation of breathing, followed by a loss of heartbeat in all 10 of the anesthetized goats, confirmed that use of this site consistently resulted in effective euthanasia. CONCLUSIONS AND CLINICAL RELEVANCE Damage to the brainstem and key adjacent structures may be accomplished by firing a PCB perpendicular to the skull over the anatomic site identified at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear.

  20. The Use of a Non-Penetrating Captive Bolt for the Euthanasia of Neonate Piglets.

    Science.gov (United States)

    Grist, Andrew; Lines, Jeff A; Knowles, Toby G; Mason, Charles W; Wotton, Stephen B

    2018-04-02

    The most common method for the on-farm euthanasia of neonate piglets is reported to be manual blunt force trauma. This paper presents the results of research to evaluate a mechanical non-penetrating captive bolt (the Accles and Shelvoke CASH small animal tool, Birmingham, UK) to produce an immediate stun/kill with neonate piglets. One hundred and forty-seven piglets (average dead weight = 1.20 kg ± 0.58 (standard deviation, SD), mean age = 5.8 days (median = 3)) were euthanized with the device and demonstrated immediate loss of consciousness, subjectively assessed by behavioural signs and no recovery. The result that 147 out of 147 animals were effectively stun/killed gives a 95% confidence interval for the true percentage of animals that would be effectively stun/killed of 97.5-100% with the use of the CASH small animal tool under the conditions of the current study. This research concludes that the CASH small animal tool, using a 1 grain brown coded cartridge, is suitable for producing a stun/kill in neonate piglets when applied in a frontal/parietal position.

  1. Nonlinear characterization of a bolted, industrial structure using a modal framework

    Science.gov (United States)

    Roettgen, Daniel R.; Allen, Matthew S.

    2017-02-01

    This article presents measurements from a sub assembly of an off-the-shelf automotive exhaust system containing a bolted-flange connection and uses a recently proposed modal framework to develop a nonlinear dynamic model for the structure. The nonlinear identification and characterization methods used are reviewed to highlight the strengths of the current approach and the areas where further development is needed. This marks the first use of these new testing and nonlinear identification tools, and the associated modal framework, on production hardware with a realistic joint and realistic torque levels. To screen the measurements for nonlinearities, we make use of a time frequency analysis routine designed for transient responses called the zeroed early-time fast Fourier transform (ZEFFT). This tool typically reveals the small frequency shifts and distortions that tend to occur near each mode that is affected by the nonlinearity. The damping in this structure is found to be significantly nonlinear and a Hilbert transform is used to characterize the damping versus amplitude behavior. A model is presented that captures these effects for each mode individually (e.g. assuming negligible nonlinear coupling between modes), treating each mode as a single degree-of-freedom oscillator with a spring and viscous damping element in parallel with a four parameter Iwan model. The parameters of this model are identified for each of the structure's modes that exhibited nonlinearity and the resulting nonlinear model is shown to capture the stiffness and damping accurately over a large range of response amplitudes.

  2. Experimental study on effects of drilling parameters on respirable dust production during roof bolting operations.

    Science.gov (United States)

    Jiang, Hua; Luo, Yi; McQuerrey, Joe

    2018-02-01

    Underground coalmine roof bolting operators exhibit a continued risk for overexposure to airborne levels of respirable coal and crystalline silica dust from the roof drilling operation. Inhaling these dusts can cause coal worker's pneumoconiosis and silicosis. This research explores the effect of drilling control parameters, specifically drilling bite depth, on the reduction of respirable dust generated during the drilling process. Laboratory drilling experiments were conducted and results demonstrated the feasibility of this dust control approach. Both the weight and size distribution of the dust particles collected from drilling tests with different bite depths were analyzed. The results showed that the amount of total inhalable and respirable dust was inversely proportional to the drilling bite depth. Therefore, control of the drilling process to achieve proper high-bite depth for the rock can be an important approach to reducing the generation of harmful dust. Different from conventional passive engineering controls, such as mist drilling and ventilation approaches, this approach is proactive and can cut down the generation of respirable dust from the source. These findings can be used to develop an integrated drilling control algorithm to achieve the best drilling efficiency as well as reducing respirable dust and noise.

  3. Multi-field coupled sensing network for health monitoring of composite bolted joint

    Science.gov (United States)

    Wang, Yishou; Qing, Xinlin; Dong, Liang; Banerjee, Sourav

    2016-04-01

    Advanced fiber reinforced composite materials are becoming the main structural materials of next generation of aircraft because of their high strength and stiffness to weight ratios, and excellent designability. As key components of large composite structures, joints play important roles to ensure the integrity of the composite structures. However, it is very difficult to analyze the strength and failure modes of composite joints due to their complex nonlinear coupling factors. Therefore, there is a need to monitor, diagnose, evaluate and predict the structure state of composite joints. This paper proposes a multi-field coupled sensing network for health monitoring of composite bolted joints. Major work of this paper includes: 1) The concept of multifunctional sensor layer integrated with eddy current sensors, Rogowski coil and arrayed piezoelectric sensors; 2) Development of the process for integrating the eddy current sensor foil, Rogowski coil and piezoelectric sensor array in multifunctional sensor layer; 3) A new concept of smart composite joint with multifunctional sensing capability. The challenges for building such a structural state sensing system and some solutions to address the challenges are also discussed in the study.

  4. The Use of a Non-Penetrating Captive Bolt for the Euthanasia of Neonate Piglets

    Directory of Open Access Journals (Sweden)

    Andrew Grist

    2018-04-01

    Full Text Available The most common method for the on-farm euthanasia of neonate piglets is reported to be manual blunt force trauma. This paper presents the results of research to evaluate a mechanical non-penetrating captive bolt (the Accles and Shelvoke CASH small animal tool, Birmingham, UK to produce an immediate stun/kill with neonate piglets. One hundred and forty-seven piglets (average dead weight = 1.20 kg ± 0.58 (standard deviation, SD, mean age = 5.8 days (median = 3 were euthanized with the device and demonstrated immediate loss of consciousness, subjectively assessed by behavioural signs and no recovery. The result that 147 out of 147 animals were effectively stun/killed gives a 95% confidence interval for the true percentage of animals that would be effectively stun/killed of 97.5–100% with the use of the CASH small animal tool under the conditions of the current study. This research concludes that the CASH small animal tool, using a 1 grain brown coded cartridge, is suitable for producing a stun/kill in neonate piglets when applied in a frontal/parietal position.

  5. Application of the cylindrically guided wave technique for bolt and pump-shaft inspections

    International Nuclear Information System (INIS)

    Light, G.M.; Ruescher, E.H.; Bloom, E.A.; Tsai, Y.M.

    1990-01-01

    Southwest Research Institute (SwRI) has been working with the cylindrically guided wave technique (CGWT) since late 1982. The initial work was aimed at inspecting reactor pressure vessel hold-down studs. The CGWT was shown to be able to detect defects as small as 0.060 inch (1.5 mm) deep through metal paths up to 120 inches (304 cm) in stud bolt carbon steel. Later developments in the application of CGWT were aimed at inspecting reactor coolant pump (RCP) shafts. The RCP shafts are usually approximately 2 meters long and have changing diameters along the length, from approximately 12 cm to 23 cm in discrete steps. The pump shafts have been susceptible to small cracks and can be inspected most cost-effectively from the top of the shaft. A matrix transducer composed of six 1-inch (2.54-cm) diameter transducers along with pulsing and receiving electronics (EPRI Pump-Shaft Inspection System) was developed during 1988. A patent application for this technology has been made. This report describes the work conducted during 1989 and the results obtained

  6. Continuous miner and friction bolts play key roles in Highland's move underground

    International Nuclear Information System (INIS)

    Scott, J.J.; Jackson, D.

    1977-01-01

    Exxon has added underground mining operations to the open pits at its Highland uranium mine and mill complex 60 mi northeast of Casper in the Powder River Basin and has, in the process, adopted some innovative mining techniques. A continuous shield miner is being used in conjunction with continuous ground support--thought to be the first truly successful combination of these techniques in a US uranium mine. Highland miners are also making extensive use of ''Split Sets,'' a patented friction rock bolt system invented in 1973, which has proven to be a successful cost-saving substitute for timber supports in Highland's soft, water-saturated, extremely unstable sediments. Initial mine production at Highland began in July 1972, and the mill started up the following October. Design capacity at startup was 2,000 tpd, a figure that has since been expanded to 3,000 tpd through mill modifications but without a major construction program. Current production is about 2 million lb per year of U 3 O 8

  7. Contact with friction modeling for the study of a bolted junction

    International Nuclear Information System (INIS)

    Lebon, F.; Raous, M.; Boulegues, D.

    1987-01-01

    Many structural analysis problems are concerned by contact phenomena. A good knowledge of the contact displacements and the contact forces between the different parts of the structure is generally essential in structure assembling. The special boundary behaviour has a strong influence on the distribution of the stresses in the whole structure and on his total fiability. The contact behaviour is strongly non linear because of the non penetration conditions on the one hand, and because of the friction on the other. On such problems the real contact zone and the contact forces are unknown 'a priori' and have to be determined during the resolution. The non-penetration is characterized by unilateral conditions and the friction is described by a constitutive law (Coulomb friction law). The application presented here concerns the assembling of the three parts of a bolted junction using a pressing ring. There are three contact zones in this program. A good description of the contact phenomena is essential to ensure tightness. Our methods are based on projection techniques coupled with overrelaxed Gauss-Seidel methods including condensation procedures (reduction of the number of variables). Non linear programming methods and iterative procedures on special boundary conditions are also used. (orig./HP)

  8. [External cephalic version].

    Science.gov (United States)

    Navarro-Santana, B; Duarez-Coronado, M; Plaza-Arranz, J

    2016-08-01

    To analyze the rate of successful external cephalic versions in our center and caesarean sections that would be avoided with the use of external cephalic versions. From January 2012 to March 2016 external cephalic versions carried out at our center, which were a total of 52. We collected data about female age, gestational age at the time of the external cephalic version, maternal body mass index (BMI), fetal variety and situation, fetal weight, parity, location of the placenta, amniotic fluid index (ILA), tocolysis, analgesia, and newborn weight at birth, minor adverse effects (dizziness, hypotension and maternal pain) and major adverse effects (tachycardia, bradycardia, decelerations and emergency cesarean section). 45% of the versions were unsuccessful and 55% were successful. The percentage of successful vaginal delivery in versions was 84% (4% were instrumental) and 15% of caesarean sections. With respect to the variables studied, only significant differences in birth weight were found; suggesting that birth weight it is related to the outcome of external cephalic version. Probably we did not find significant differences due to the number of patients studied. For women with breech presentation, we recommend external cephalic version before the expectant management or performing a cesarean section. The external cephalic version increases the proportion of fetuses in cephalic presentation and also decreases the rate of caesarean sections.

  9. Piezosurgery in External Dacryocystorhinostomy.

    Science.gov (United States)

    Czyz, Craig N; Fowler, Amy M; Dutton, Jonathan J; Cahill, Kenneth V; Foster, Jill A; Hill, Robert H; Everman, Kelly R; Nabavi, Cameron B

    Dacryocystorhinostomy (DCR) can be performed via an external or endoscopic approach. The use of ultrasonic or piezosurgery has been well described for endoscopic DCRs but is lacking for external DCRs. This study presents a case series of external DCRs performed using piezosurgery evaluating results and complications. Prospective, consecutive case series of patients undergoing primary external DCR for lacrimal drainage insufficiency. A standard external DCR technique was used using 1 of 2 piezosurgery systems for all bone incision. All patients received silicone intubation to the lacrimal system. Surgical outcome was measured in terms of patient-reported epiphora as follows: 1) complete resolution, 2) improvement >50%, 3) improvement 50% improvement. There were 4 patients (7%) who had <50% improvement. There was 1 (2%) intraoperative complication and 2 (4%) postoperative complications recorded. Piezourgery is a viable modality for performing external DCRs. The lack of surgical complications shows a potential for decreased soft tissues damage. The surgical success rate based on patient-reported epiphora is similar to those published for mechanical external DCRs. This modality may benefit the novice surgeon in the reduction of soft and mucosal tissue damage.

  10. Structural Analysis of Cabinet Support under Static and Seismic Loads

    International Nuclear Information System (INIS)

    Jung, Kwangsub; Lee, Sangjin; Oh, Jinho

    2014-01-01

    The cabinet support consists of frames including steel channels and steel square tubes. Four tap holes for screw bolts are located on the support frame of a steel channel to fix the cabinet on the support. The channels and square tubes are assembled by welded joints. The cabinet supports are installed on the outer walls of the reactor concrete island. The KEPIC code, MNF, is used for the design of the cabinet support. In this work, the structural integrity of the cabinet support is analyzed under consideration of static and seismic loads. A 3-D finite element model of the cabinet support was developed. The structural integrity of the cabinet support under postulated service loading conditions was evaluated through a static analysis, modal analysis, and response spectrum analysis. From the structural analysis results, it was concluded that the structural integrity of the cabinet support is guaranteed

  11. Automated External Defibrillator

    Science.gov (United States)

    ... leads to a 10 percent reduction in survival. Training To Use an Automated External Defibrillator Learning how to use an AED and taking a CPR (cardiopulmonary resuscitation) course are helpful. However, if trained ...

  12. Energy policy and externalities

    International Nuclear Information System (INIS)

    Bertel, E.; Fraser, P.

    2002-01-01

    External costs of energy have been assessed in a number of authoritative and reliable studies based upon widely accepted methodologies such as life cycle analysis (LCA). However, although those costs are recognised by most stakeholders and decision makers, results from analytical work on externalities and LCA studies are seldom used in policy making. The International Energy Agency (IEA) and the Nuclear Energy Agency (NEA) convened a joint workshop in November 2001 to offer experts and policy makers an opportunity to present state-of-the-art results from analytical work on externalities and debate issues related to the relevance of external costs and LCA for policy-making purposes. The findings from the workshop highlight the need for further work in the field and the potential rote of international organisations like the IEA and the NEA in this context. (authors)

  13. Externally Verifiable Oblivious RAM

    Directory of Open Access Journals (Sweden)

    Gancher Joshua

    2017-04-01

    Full Text Available We present the idea of externally verifiable oblivious RAM (ORAM. Our goal is to allow a client and server carrying out an ORAM protocol to have disputes adjudicated by a third party, allowing for the enforcement of penalties against an unreliable or malicious server. We give a security definition that guarantees protection not only against a malicious server but also against a client making false accusations. We then give modifications of the Path ORAM [15] and Ring ORAM [9] protocols that meet this security definition. These protocols both have the same asymptotic runtimes as the semi-honest original versions and require the external verifier to be involved only when the client or server deviates from the protocol. Finally, we implement externally verified ORAM, along with an automated cryptocurrency contract to use as the external verifier.

  14. Analysis of external events - Nuclear Power Plant Dukovany

    International Nuclear Information System (INIS)

    Hladky, Milan

    2000-01-01

    PSA of external events at level 1 covers internal events, floods, fires, other external events are not included yet. Shutdown PSA takes into account internal events, floods, fires, heavy load drop, other external events are not included yet. Final safety analysis report was conducted after 10 years of operation for all Dukovany operational units. Probabilistic approach was used for analysis of aircraft drop and external man-induced events. The risk caused by man-induced events was found to be negligible and was accepted by State Office for Nuclear Safety (SONS)

  15. Degradation theories of concrete and development of a new deviatoric model in incremental tangent formulation: limit analysis applied to case of anchor bolts embedded in concrete

    International Nuclear Information System (INIS)

    Ung Quoc, H.

    2003-12-01

    This research is achieved in the general framework of the study of the concrete behaviour. It has for objective the development of a new behaviour model satisfying to the particular requirements for an industrial exploitation. After the analysis of different existent models, a first development has concerned models based on the smeared crack theory. A new formulation of the theory permitted to overcome the stress locking problem. However, the analysis showed the persistence of some limits inert to this approach in spite of this improvement. Then, an analysis of the physical mechanisms of the concrete degradation has been achieved and permitted to develop the new damage model MODEV. The general formulation of this model is based on the theory of the thermodynamics and applied to the case of the heterogeneous and brittle materials. The MODEV model considers two damage mechanisms: extension and sliding. The model considers also that the relative tangent displacement between microcracks lips is responsible of the strain irreversibility. Thus, the rate of inelastic strain becomes function of the damage and the heterogeneity index of the material. The unilateral effect is taken in account as an elastic hardening or softening process according to re-closing or reopening of cracks. The model is written within the framework of non standard generalised materials in incremental tangent formulation and implemented in the general finite element code SYMPHONIE. The validation of the model has been achieved on the basis of several tests issued from the literature. The second part of this research has concerned the development of the CHEVILAB software. This simulation tool based on the limit analysis approach permit the evaluation of the ultimate load capacity of anchors bolts. The kinematics approach of the limit analysis has been adapted to the problem of anchors while considering several specific failure mechanisms. This approach has been validated then by comparison with the

  16. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  17. Beam loading

    International Nuclear Information System (INIS)

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed. (author)

  18. Development of an FPGA-based multipoint laser pyroshock measurement system for explosive bolts

    International Nuclear Information System (INIS)

    Abbas, Syed Haider; Lee, Jung-Ryul; Jang, Jae-Kyeong; Kim, Zaeill

    2016-01-01

    Pyroshock can cause failure to the objective of an aerospace structure by damaging its sensitive electronic equipment, which is responsible for performing decisive operations. A pyroshock is the high intensity shock wave that is generated when a pyrotechnic device is explosively triggered to separate, release, or activate structural subsystems of an aerospace architecture. Pyroshock measurement plays an important role in experimental simulations to understand the characteristics of pyroshock on the host structure. This paper presents a technology to measure a pyroshock wave at multiple points using laser Doppler vibrometers (LDVs). These LDVs detect the pyroshock wave generated due to an explosive-based pyrotechnical event. Field programmable gate array (FPGA) based data acquisition is used in the study to acquire pyroshock signals simultaneously from multiple channels. This paper describes the complete system design for multipoint pyroshock measurement. The firmware architecture for the implementation of multichannel data acquisition on an FPGA-based development board is also discussed. An experiment using explosive bolts was configured to test the reliability of the system. Pyroshock was generated using explosive excitation on a 22-mm-thick steel plate. Three LDVs were deployed to capture the pyroshock wave at different points. The pyroshocks captured were displayed as acceleration plots. The results showed that our system effectively captured the pyroshock wave with a peak-to-peak magnitude of 303 741 g. The contribution of this paper is a specialized architecture of firmware design programmed in FPGA for data acquisition of large amount of multichannel pyroshock data. The advantages of the developed system are the near-field, multipoint, non-contact, and remote measurement of a pyroshock wave, which is dangerous and expensive to produce in aerospace pyrotechnic tests.

  19. Development of an FPGA-based multipoint laser pyroshock measurement system for explosive bolts

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Syed Haider; Lee, Jung-Ryul [Department of Aerospace Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Jang, Jae-Kyeong [The Engineering Institute-Korea, Chonbuk National University, Jeonju (Korea, Republic of); Kim, Zaeill [The 4th R& D Institute-1st directorate, Agency for Defense Development, Daejeon (Korea, Republic of)

    2016-07-15

    Pyroshock can cause failure to the objective of an aerospace structure by damaging its sensitive electronic equipment, which is responsible for performing decisive operations. A pyroshock is the high intensity shock wave that is generated when a pyrotechnic device is explosively triggered to separate, release, or activate structural subsystems of an aerospace architecture. Pyroshock measurement plays an important role in experimental simulations to understand the characteristics of pyroshock on the host structure. This paper presents a technology to measure a pyroshock wave at multiple points using laser Doppler vibrometers (LDVs). These LDVs detect the pyroshock wave generated due to an explosive-based pyrotechnical event. Field programmable gate array (FPGA) based data acquisition is used in the study to acquire pyroshock signals simultaneously from multiple channels. This paper describes the complete system design for multipoint pyroshock measurement. The firmware architecture for the implementation of multichannel data acquisition on an FPGA-based development board is also discussed. An experiment using explosive bolts was configured to test the reliability of the system. Pyroshock was generated using explosive excitation on a 22-mm-thick steel plate. Three LDVs were deployed to capture the pyroshock wave at different points. The pyroshocks captured were displayed as acceleration plots. The results showed that our system effectively captured the pyroshock wave with a peak-to-peak magnitude of 303 741 g. The contribution of this paper is a specialized architecture of firmware design programmed in FPGA for data acquisition of large amount of multichannel pyroshock data. The advantages of the developed system are the near-field, multipoint, non-contact, and remote measurement of a pyroshock wave, which is dangerous and expensive to produce in aerospace pyrotechnic tests.

  20. Application of panel methods in external store load calculations

    CSIR Research Space (South Africa)

    Van Den Broek, GJ

    1984-07-01

    Full Text Available below the wing is first considered; then, the effect of the wing panelling in the leading edge region, where the singularity distributions show large gradients, on the flow field is studied. Both lift and thickness effects are taken into account....

  1. Load sensor

    NARCIS (Netherlands)

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder

  2. Carbohydrate Loading.

    Science.gov (United States)

    Csernus, Marilyn

    Carbohydrate loading is a frequently used technique to improve performance by altering an athlete's diet. The objective is to increase glycogen stored in muscles for use in prolonged strenuous exercise. For two to three days, the athlete consumes a diet that is low in carbohydrates and high in fat and protein while continuing to exercise and…

  3. Bearing Stress at Failure of Double-Lap Hybrid Joints in Woven Fabric Kenaf Fiber Composite Plates under Quasi-static Loading

    Directory of Open Access Journals (Sweden)

    Lee Sim Yee

    2017-01-01

    Full Text Available The present paper is focused on the bearing stress at failure of double-lap woven fabric kenaf fiber reinforced polymer (KFRP hybrid bonded-bolted joints in experimental frameworks. The effects of different normalized plate width (plate width/hole diameter, W/d, lay-up types and bolt loads were incorporated in current study as specified in testing series. Generally, hybrid joint coupons separated within adhesive layer prior to net-tension failure or bearing/net-tension failure. The bearing stress at failure increased as W/d ratio increment, critical W/d is given as four and three in clamped and finger tight condition respectively. Lay-up types present insignificant effect to bearing stress at failure due to low volume fiber fraction in kenaf fiber composites. Combination of thicker and clamped conditions plate demonstrated greater bearing stress than equivalent finger-tight (FT conditions due to higher load transferred from friction, as expected.

  4. Malignant external otitis

    International Nuclear Information System (INIS)

    Dupuch, K.M.; Iryboz, T.; Firat, M.; Levy, C.; Tubiana, J.M.

    1991-01-01

    This paper illustrates the value of CT and MR in early diagnosis and spread of malignant external otitis. The authors retrospectively analyzed 15 patients with proved malignant external otitis examined with postcontrast high-resolution CT (15/15) and MR (6/15) (T1- and T2-weighting). Gallium studies were done in 6/15 patients. Early diagnosis was made when CT demonstrated a soft-tissue mass of the external auditory canal associated with scattered zones of cortical bone erosions (13/15). Spread of the disease was better delineated by MR than CT, especially skull base extension (6/15). Temporomandibular joint involvement with extension into parotid or/and masticator spaces 6/15 was as well detected with CT as with MR. If CT remains the first and best procedure for diagnosis, MR - despite its cost - appears a good procedure to depict exact anatomic spread, allowing therapeutic management

  5. Productivity Change and Externalities

    DEFF Research Database (Denmark)

    Kravtsova, Victoria

    2014-01-01

    This paper contributes to the analysis of the impact of externalities on the host country's total factor productivity by taking into account different dimensions of spillover effects. Namely, engagement in exporting and foreign ownership is generally perceived as being beneficial to individual...... firms and the economy as a whole. The approach used in the current research accounts for different internal as well as external factors that individual firms face and evaluates the effect on changes in productivity, technology as well as the efficiency of domestic firms. The empirical analysis focuses...... on Hungary. While the country leads the group of post-socialist countries in the amount of attracted foreign direct investments (FDI) the effect of this policy on the economy remains unclear. The research finds that different externalities play a different role in productivity, technological and efficiency...

  6. Externality or sustainability economics?

    International Nuclear Information System (INIS)

    Bergh, Jeroen C.J.M. van den

    2010-01-01

    In an effort to develop 'sustainability economics' Baumgaertner and Quaas (2010) neglect the central concept of environmental economics-'environmental externality'. This note proposes a possible connection between the concepts of environmental externality and sustainability. In addition, attention is asked for other aspects of 'sustainability economics', namely the distinction weak/strong sustainability, spatial sustainability and sustainable trade, distinctive sustainability policy, and the ideas of early 'sustainability economists'. I argue that both sustainability and externalities reflect a systems perspective and propose that effective sustainability solutions require that more attention is given to system feedbacks, notably other-regarding preferences and social interactions, and energy and environmental rebound. The case of climate change and policy is used to illustrate particular statements. As a conclusion, a list of 20 insights and suggestions for research is offered. (author)

  7. Metasurface external cavity laser

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Luyao, E-mail: luyaoxu.ee@ucla.edu; Curwen, Christopher A.; Williams, Benjamin S. [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); California NanoSystems Institute, University of California, Los Angeles, California 90095 (United States); Hon, Philip W. C.; Itoh, Tatsuo [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); Chen, Qi-Sheng [Northrop Grumman Aerospace Systems, Redondo Beach, California 90278 (United States)

    2015-11-30

    A vertical-external-cavity surface-emitting-laser is demonstrated in the terahertz range, which is based upon an amplifying metasurface reflector composed of a sub-wavelength array of antenna-coupled quantum-cascade sub-cavities. Lasing is possible when the metasurface reflector is placed into a low-loss external cavity such that the external cavity—not the sub-cavities—determines the beam properties. A near-Gaussian beam of 4.3° × 5.1° divergence is observed and an output power level >5 mW is achieved. The polarized response of the metasurface allows the use of a wire-grid polarizer as an output coupler that is continuously tunable.

  8. Performance of Retrofitted Self-Compacting Concrete-Filled Steel Tube Beams Using External Steel Plates

    Directory of Open Access Journals (Sweden)

    Ahmed A. M. AL-Shaar

    2018-01-01

    Full Text Available Self-compacting concrete-filled steel tube (SCCFST beams, similar to other structural members, necessitate retrofitting for many causes. However, research on SCCFST beams externally retrofitted by bolted steel plates has seldom been explored in the literature. This paper aims at experimentally investigating the retrofitting performance of square self-compacting concrete-filled steel tube (SCCFST beams using bolted steel plates with three different retrofitting schemes including varied configurations and two different steel plate lengths under flexure. A total of 18 specimens which consist of 12 retrofitted SCCFST beams, three unretrofitted (control SCCFST beams, and three hollow steel tubes were used. The flexural behaviour of the retrofitted SCCFST beams was examined regarding flexural strength, failure modes, and moment versus deflection curves, energy absorption, and ductility. Experimental results revealed that the implemented retrofitting schemes efficiently improve the moment carrying capacity and stiffness of the retrofitted SCCFST beams compared to the control beams. The increment in flexural strength ranged from 1% to 46%. Furthermore, the adopted retrofitting schemes were able to restore the energy absorption and ductility of the damaged beams in the range of 35% to 75% of the original beam ductility. Furthermore, a theoretical model was suggested to predict the moment capacity of the retrofitted SCCFST beams. The theoretical model results were in good agreement with the test results.

  9. The External Mind

    DEFF Research Database (Denmark)

    , Extended Mind and Distributed Cognition by Claudio Paolucci pp. 69-96 The Social Horizon of Embodied Language and Material Symbols by Riccardo Fusaroli pp. 97-123 Semiotics and Theories of Situated/Distributed Action and Cognition: a Dialogue and Many Intersections by Tommaso Granelli pp. 125-167 Building......The External Mind: an Introduction by Riccardo Fusaroli, Claudio Paolucci pp. 3-31 The sign of the Hand: Symbolic Practices and the Extended Mind by Massimiliano Cappuccio, Michael Wheeler pp. 33-55 The Overextended Mind by Shaun Gallagher pp. 57-68 The "External Mind": Semiotics, Pragmatism...

  10. Ultrasonic testing of core baffle former bolts of the core tanks of pressurised water reactors; Ultraschallpruefung von Kernumfassungsschrauben der Kernbehaelter von Druckwasserreaktoren

    Energy Technology Data Exchange (ETDEWEB)

    Bies, Christian M.; Alaerts, Louis; Bonitz, Frank W. [Westinghouse Electric Germany GmbH, Mannheim (Germany); Devlin, Russell S.; Minogue, Patrick [WesDyne International, Madison, PA (United States)

    2013-07-01

    This article presents the MIDAS VI testing robot used by Westinghouse / WesDyne. This is a remotely operated underwater vehicle which positions ultrasonic probes under camera control. This vehicle makes it possible to substantially reduce the time required for setting up and preparing ultrasonic tests on core baffle former bolts. It has also accelerated the test procedure itself. Test methods have also been developed for bolt types which were hitherto considered incapable of being tested. One of these methods is based on a phased array probe. The article also reports on experiences gained over the course of years in testing core baffle former bolts in European nuclear power plants using the SUPREEM testing robot.

  11. Load sensor

    OpenAIRE

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder forming 30-60% by volume of the composite, and wherein the PZT powder forms 40-50% by volume of the composite.

  12. Effect of CO2 enrichment on the glucosinolate contents under different nitrogen levels in bolting stem of Chinese kale (Brassica alboglabra L.).

    Science.gov (United States)

    La, Gui-xiao; Fang, Ping; Teng, Yi-bo; Li, Ya-juan; Lin, Xian-yong

    2009-06-01

    The effects of CO(2) enrichment on the growth and glucosinolate (GS) concentrations in the bolting stem of Chinese kale (Brassica alboglabra L.) treated with three nitrogen (N) concentrations (5, 10, and 20 mmol/L) were investigated. Height, stem thickness, and dry weights of the total aerial parts, bolting stems, and roots, as well as the root to shoot ratio, significantly increased as CO(2) concentration was elevated from 350 to 800 microl/L at each N concentration. In the edible part of the bolting stem, 11 individual GSs were identified, including 7 aliphatic and 4 indolyl GSs. GS concentration was affected by the elevated CO(2) concentration, N concentration, and CO(2)xN interaction. At 5 and 10 mmol N/L, the concentrations of aliphatic GSs and total GSs significantly increased, whereas those of indolyl GSs were not affected, by elevated atmospheric CO(2). However, at 20 mmol N/L, elevated CO(2) had no significant effects on the concentrations of total GSs and total indolyl GSs, but the concentrations of total aliphatic GSs significantly increased. Moreover, the bolting stem carbon (C) content increased, whereas the N and sulfur (S) contents decreased under elevated CO(2) concentration in the three N treatments, resulting in changes in the C/N and N/S ratios. Also the C/N ratio is not a reliable predictor of change of GS concentration, while the changes in N and S contents and the N/S ratio at the elevated CO(2) concentration may influence the GS concentration in Chinese kale bolting stems. The results demonstrate that high nitrogen supply is beneficial for the growth of Chinese kale, but not for the GS concentration in bolting stems, under elevated CO(2) condition.

  13. Effect of CO2 enrichment on the glucosinolate contents under different nitrogen levels in bolting stem of Chinese kale (Brassica alboglabra L.)*

    Science.gov (United States)

    La, Gui-xiao; Fang, Ping; Teng, Yi-bo; Li, Ya-juan; Lin, Xian-yong

    2009-01-01

    The effects of CO2 enrichment on the growth and glucosinolate (GS) concentrations in the bolting stem of Chinese kale (Brassica alboglabra L.) treated with three nitrogen (N) concentrations (5, 10, and 20 mmol/L) were investigated. Height, stem thickness, and dry weights of the total aerial parts, bolting stems, and roots, as well as the root to shoot ratio, significantly increased as CO2 concentration was elevated from 350 to 800 μl/L at each N concentration. In the edible part of the bolting stem, 11 individual GSs were identified, including 7 aliphatic and 4 indolyl GSs. GS concentration was affected by the elevated CO2 concentration, N concentration, and CO2×N interaction. At 5 and 10 mmol N/L, the concentrations of aliphatic GSs and total GSs significantly increased, whereas those of indolyl GSs were not affected, by elevated atmospheric CO2. However, at 20 mmol N/L, elevated CO2 had no significant effects on the concentrations of total GSs and total indolyl GSs, but the concentrations of total aliphatic GSs significantly increased. Moreover, the bolting stem carbon (C) content increased, whereas the N and sulfur (S) contents decreased under elevated CO2 concentration in the three N treatments, resulting in changes in the C/N and N/S ratios. Also the C/N ratio is not a reliable predictor of change of GS concentration, while the changes in N and S contents and the N/S ratio at the elevated CO2 concentration may influence the GS concentration in Chinese kale bolting stems. The results demonstrate that high nitrogen supply is beneficial for the growth of Chinese kale, but not for the GS concentration in bolting stems, under elevated CO2 condition. PMID:19489111

  14. Externalities - an analysis using the EU ExternE-results

    International Nuclear Information System (INIS)

    2003-10-01

    The EU project ExternE quantified the externalities for the different energy technologies. In this work, the ExternE results are used in a MARKAL-analysis for the Nordic countries. The analysis does not go into detail, but gives some interesting indications: The external costs are not fully covered in the Nordic energy systems, the present taxes and charges are not high enough. The emissions from the energy systems would be strongly reduced, if taxes/environmental charges were set at the level ExternE calculate. The emissions from power production would be reduced most. Renewable energy sources and natural gas dominate the energy systems in the ExternE case

  15. External costs of electricity

    International Nuclear Information System (INIS)

    Rabl, A.; Spadaro, J.V.

    2005-01-01

    This article presents a synthesis of the ExternE project (External costs of Energy) of the European community about the external costs of power generation. Pollution impacts are calculated using an 'impact pathways' analysis, i.e. an analysis of the emission - dispersion - dose-response function - cost evaluation chain. Results are presented for different fuel cycles (with several technological variants) with their confidence intervals. The environmental impact costs are particularly high for coal: for instance, in France, for coal-fired power plants it is of the same order as the electricity retail price. For natural gas, this cost is about a third of the one for coal. On the contrary, the environmental impact costs for nuclear and renewable energies are low, typically of few per cent of the electricity price. The main part of these costs corresponds to the sanitary impacts, in particular the untimely mortality. In order to avoid any controversy about the cost evaluation of mortality, the reduction of the expectation of life due to the different fuel cycles is also indicated and the risks linked with nuclear energy are presented using several comparisons. (J.S.)

  16. On parabolic external maps

    DEFF Research Database (Denmark)

    Lomonaco, Luna; Petersen, Carsten Lunde; Shen, Weixiao

    2017-01-01

    We prove that any C1+BV degree d ≥ 2 circle covering h having all periodic orbits weakly expanding, is conjugate by a C1+BV diffeomorphism to a metrically expanding map. We use this to connect the space of parabolic external maps (coming from the theory of parabolic-like maps) to metrically expan...

  17. Stochastic Control - External Models

    DEFF Research Database (Denmark)

    Poulsen, Niels Kjølstad

    2005-01-01

    This note is devoted to control of stochastic systems described in discrete time. We are concerned with external descriptions or transfer function model, where we have a dynamic model for the input output relation only (i.e.. no direct internal information). The methods are based on LTI systems...

  18. 緩み止め植込みボルトにおける薄肉変形部の最適寸法について

    OpenAIRE

    肖, 陽; 久原, 昌浩; 野田, 尚昭; 斉藤, 金次郎; 名川, 政人; 湯本, 淳

    2008-01-01

    The bolts and nuts are widely used in various fields as important joining elements with long history. However, screw loosening is easily induced by vibration and external loads, and sometimes causes very serious accident without notice. In this paper, a special stud bolt named Super Stud Bolt (SSB) is studied, which can prevent loosening effectively. Between the upper threads and the lower threads, there is a thin walled tube which can be deformed along the axial direction so that the phase d...

  19. Experimental and Numerical Investigations of Fretting Fatigue Behavior for Steel Q235 Single-Lap Bolted Joints

    Directory of Open Access Journals (Sweden)

    Yazhou Xu

    2016-01-01

    Full Text Available This work aims to investigate the fretting fatigue life and failure mode of steel Q235B plates in single-lap bolted joints. Ten specimens were prepared and tested to fit the S-N curve. SEM (scanning electron microscope was then employed to observe fatigue crack surfaces and identify crack initiation, crack propagation, and transient fracture zones. Moreover, a FEM model was established to simulate the stress and displacement fields. The normal contact stress, tangential contact stress, and relative slipping displacement at the critical fretting zone were used to calculate FFD values and assess fretting fatigue crack initiation sites, which were in good agreement with SEM observations. Experimental results confirmed the fretting fatigue failure mode for these specimens. It was found that the crack initiation resulted from wear regions at the contact surfaces between plates, and fretting fatigue cracks occurred at a certain distance away from hole edges. The proposed FFD-N relationship is an alternative approach to evaluate fretting fatigue life of steel plates in bolted joints.

  20. Crack-depth effects in the cylindrically guided wave technique for bolt and pump-shaft inspections

    International Nuclear Information System (INIS)

    Tsai, Y.M.; Liu, S.N.; Light, G.M.

    1991-01-01

    Nuclear power plants have experienced the failures of bolts and pump shafts. The industry is concerned about nondestructive evaluation (NDE) techniques that can be applied to these components. The cylindrically guided wave technique (CGWT) has been developed to detect the simulated circumferential defects in long bolts and studs. The ultrasonic CGWT employs the zero-degree longitudinal waves constrained to travel within the boundary of the components with cylindrical shape during inspection. When longitudinal waves are guided to travel along a cylinder, and impinge onto a circumferential defect, the waves are scattered at the crack on the cylinder surface. In this work, the wave scattering at the circumferential crack on a long cylinder is investigated. The transfer factor of the scattered waves is calculated for a wide range of frequency spectra. The scattered waveform at a distance away from a crack is calculated. The effect that crack depth exerts to the waveform in CGWT is shown. CGWT signals, waveform calculation and so on are reported. (K.I.)