WorldWideScience

Sample records for externally applied magnetic

  1. Surface modification of ZnS films by applying an external magnetic field in vacuum chamber

    Science.gov (United States)

    Ehsani, M. H.; Zarei Moghadam, R.; Rezagholipour Dizaji, H.; Kameli, P.

    2017-09-01

    In this paper, ZnS films were prepared using pulsed laser deposition technique in vacuum chamber in the presence and absence of an external magnetic field. The applied magnetic field effects on optical properties and film growth conditions were studied. For this reason, morphological, structural and optical properties of the grown films have been investigated by atomic force microscopy, field emission scanning electron microscopy, x-ray diffraction and UV-vis spectroscopy analysis techniques. The structural studies revealed that the ZnS films deposited at 200 °C crystallized in hexagonal structure. The results showed the improvement of the film crystallinity upon grain size increment and the surface morphology modification resulted from applying an external magnetic field. Using the UV-vis spectroscopy data, absorption coefficient (α), refractive index (n) and extinction coefficient (k) of the samples were calculated. The band gap energy (E g) and Urbach energy were also calculated by Tauc, ASF and DASF methods. The results show that by applying magnetic field, the band gap and Urbach energies reduced, due to improvement in the film crystallinity. For describing the magnetic field effect, a simulation of applied magnetic field effect on vapor flux in vacuum chamber was performed using Multi-Physics COMSOL package.

  2. Influence of an externally applied magnetic field on vectorial interaction in LiNbO3:Fe crystals

    DEFF Research Database (Denmark)

    Dam-Hansen, C.; Johansen, P.M.; Petersen, P.M.

    1995-01-01

    An experimental investigation of the influence of an externally applied magnetic field on the dynamic grating formation in iron-doped lithium niobate is carried out. The diffraction efficiency and the two-beam gain depends strongly on the applied magnetic field. We observe changes in the two...

  3. Unsteady flow of two-phase fluid in circular pipes under applied external magnetic and electrical fields

    Energy Technology Data Exchange (ETDEWEB)

    Gedik, Engin; Recebli, Ziyaddin [Faculty of Technology, Karabuk University, TR-78050, Karabuk (Turkey); Kurt, Hueseyin [Faculty of Engineering, Karabuk University, TR-78050, Karabuk (Turkey); Kecebas, Ali [Faculty of Technology, Afyon Kocatepe University, TR-03200, Afyon (Turkey)

    2012-03-15

    The unsteady viscous incompressible and electrically conducting of two-phase fluid flow in circular pipes with external magnetic and electrical field is considered in this present study. Effects of both uniform transverse external magnetic and electrical fields applied perpendicular to the fluid and each other on the two-phase (solid/liquid) unsteady flow is investigated numerically. While iron powders are being used as the first phase of two-phase fluid, pure water was used as the second phase. The system of the derived governing equations, which are based on the Navier-Stokes equations including Maxwell equations, are solved numerically by using Pdex4 function on the Matlab for both phases. The originality of this study is that, in addition to magnetic field, the effect of electrical field on two-phase unsteady fluids is being examined. The magnetic field which is applied on flow decreases the velocity of both phases, whereas the electrical field applied along with magnetic field acted to increase and decrease the velocity values depending on the direction of electrical field. Electrical field alone did not display any impact on two-phase flow. On the other hand, analytical and numerical results are compared and favorable agreements have been obtained. (authors)

  4. Flow between caoxial rotating disks: with and without externally applied magnetic field

    Directory of Open Access Journals (Sweden)

    R. K. Bhatnagar

    1981-01-01

    when such a fluid is confined between two infinite rotating coaxial disks. The governing system of a pair of non-linear ordinary differential equation is solved by treating Reynolds number to small. The three cases discussed are: (I one disks is held at rest while other rotates with a constant angular velocity, (ii one disk rorates faster than the other but in the same sense and (iii the disks rotate in opposite senses and with different angular velocities. The radial, tranverse and axial components of the velocity field are plotted for the above three cases for different values of the Reynolds number. The results obtained for a viscoelastic fluid are compared with those for a Newtonian fluid. The velocity field for case (i is also computed when a magnetic field is applied in a direction perpendicular to the discs and the results are compared with the case when magnetic field is absent. Some interesting features are observed for a viscoelastic fluid.

  5. Electromagnetic response of non-trivially shaped superconductors in external magnetic fields and with applied currents

    International Nuclear Information System (INIS)

    Cabral, Leonardo Ribeiro Eulalio; Aguiar, Jose Albino Oliveira de

    2002-01-01

    Full text: The study of the electromagnetic response of high-T c superconductors is essential for future technological applications. Such materials are hard type II superconductors, where the mixed state (a state characterized by quantized normal flux tubes - also called vortices - immersed in a superconductor phase) occupies most of the phase diagram. Therefore, the electromagnetic properties are dictated by the vortex dynamics in these materials. One has also to consider the presence of structural defects and thermal effects, which turn the vortex dynamics very complex. These difficulties may be overcome throughout a macroscopic description, also known as continuum approximation, of the electromagnetic fields in superconductors, obtained from critical state models and constitutive relations E = E(j) and H = H(B) (where E is the electric field generated by moving vortices, j the current density, B the induction - related to the local density of vortices - and H the reversible magnetic field that is in equilibrium with B). In superconductors with negligible demagnetization factors, such as long cylinders and bars with applied magnetic fields and/or currents along their longer dimensions, the Meissner state and the flux penetration is quite well understood. However, the actual specimen shape plays an important role on the electromagnetic behavior of superconductors. Numerical methods are often employed, since such cases are hard to treat analytically. In this work we studied the electromagnetic response of superconductors with various shapes. The Meissner state is obtained for thin curved strips and long cylinders with arbitrary cross-section, in perpendicular field and with applied currents. The flux penetration is numerically calculated for thin curved strips for the Bean (j c =const.) and the Kim (j c (B) = j c0 /(1 + βB)) models. (author)

  6. Effect of external magnetic effect of external magnetic field annealing on magnetic texture of Mo containing NANOPERM-type alloys

    International Nuclear Information System (INIS)

    Kanuch, T.; Miglierini, M.; Greneche, J.-M.; Skorvanek, I.; Schaaf, P.

    2006-01-01

    External magnetic fields are known to modify microstructure of materials during their solidification and/or crystallisation. In an external magnetic field strong particle to particle interactions lead to a highly anisotropic microstructure. If the alloy is in ferromagnetic state, stronger particle magnetization - external field interactions and also particle-to-particle couplings are expected. To reveal the magnetic texture, originally amorphous precursors of Fe 76 Mo 8 Cu 1 B 15 were annealed at 510 grad C and 550 grad C in an external longitudinal and transverse magnetic field of 0.025 T and 0.8 T, respectively. Magnetic measurements were applied to follow the changes of saturation magnetization and coercive force. Moessbauer experiments were performed at room and liquid nitrogen temperature to provide an information about orientation of with respect to an external magnetic field. The obtained results were compared with those achieved on zero field annealed samples. We can conclude that such a low external magnetic fields applied during crystallisation cause no significant changes in the magnetic microstructural anisotropy. Afterwards, magneto-optical Kerr effect (MOKE) was applied to investigate possible changes at the surface of the ribbon as a function of annealing temperature and applied magnetic field. We observed combination of uniaxial anisotropy, which originates from the shape anisotropy, and four-fold anisotropy, which is a contribution from crystallites of nanometre size embedded in the residual amorphous matrix. We expect more pronounced effects on cobalt substituted (Fe1 -x Co x ) 76 Mo 8 Cu 1 B 15 alloy. (authors)

  7. Aging and magnetism: Presenting a possible new holistic paradigm for ameliorating the aging process and the effects thereof, through externally applied physiologic PicoTesla magnetic fields.

    Science.gov (United States)

    Jacobson, Jerry; Sherlag, Benjamin

    2015-09-01

    A new holistic paradigm is proposed for slowing our genomic-based biological clocks (e.g. regulation of telomere length), and decreasing heat energy exigencies for maintenance of physiologic homeostasis. Aging is considered the result of a progressive slow burn in small volumes of tissues with increase in the quantum entropic states; producing desiccation, microscopic scarring, and disruption of cooperative coherent states. Based upon piezoelectricity, i.e. photon-phonon transductions, physiologic PicoTesla range magnetic fields may decrease the production of excessive heat energy through target specific, bio molecular resonant interactions, renormalization of intrinsic electromagnetic tissue profiles, and autonomic modulation. Prospectively, we hypothesize that deleterious effects of physical trauma, immunogenic microbiological agents, stress, and anxiety may be ameliorated. A particle-wave equation is cited to ascertain magnetic field parameters for application to the whole organism thereby achieving desired homeostasis; secondary to restoration of structure and function on quantum levels. We hypothesize that it is at the atomic level that physical events shape the flow of signals and the transmission of energy in bio molecular systems. References are made to experimental data indicating the aspecific efficacy of non-ionizing physiologic magnetic field profiles for treatment of various pathologic states. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Superconducting Sphere in an External Magnetic Field Revisited

    Science.gov (United States)

    Sazonov, Sergey N.

    2013-01-01

    The purpose of this article is to give the intelligible procedure for undergraduate students to grasp proof of the fact that the magnetic field outside the hollow superconducting sphere (superconducting shell) coincides with the field of a point magnetic dipole both when an uniform external magnetic field is applied as when a ferromagnetic sphere…

  9. The external magnetic field environment

    Science.gov (United States)

    1977-01-01

    Calculations were made to predict magnetic field intensities surrounding an aircraft following a lightning strike. Aircraft design and aircraft structural geometry were considered in the computations. A wire grid aircraft model was used to aid in magnetic flux estimation.

  10. Relaxed plasmas in external magnetic fields

    International Nuclear Information System (INIS)

    Spies, G.O.; Li, J.

    1991-08-01

    The well-known theory of relaxed plasmas (Taylor states) is extended to external magnetic fields whose field lines intersect the conducting toroidal boundary. Application to an axially symmetric, large-aspect-ratio torus with circular cross section shows that the maximum pinch ratio, and hence the phenomenon of current saturation, is independent of the external field. The relaxed state is explicitly given for an external octupole field. In this case, field reversal is inhibited near parts of the boundary if the octupole generates magnetic x-points within the plasma. (orig.)

  11. Fluxon propagation in long Josephson junctions with external magnetic field

    DEFF Research Database (Denmark)

    Olsen, O.H.; Samuelsen, Mogens Rugholm

    1981-01-01

    The reflection of a single fluxon propagating in a Josephson line cavity influenced by an external magnetic field is examined numerically. We find a single reflected fluxon, an antifluxon, collapse of the incident fluxon, fission into a higher number of antifluxons or fluxons, and formation...... of breather-like waves depending on the velocity of the incident fluxon and the magnitude of the external magnetic field. Approximations based on energy analysis describing the border lines between regions of different processes are presented. Journal of Applied Physics is copyrighted by The American...

  12. Controlled creation of nanometric skyrmions using external magnetic fields

    Science.gov (United States)

    Mochizuki, Masahito

    2017-08-01

    To exploit nanometric magnetic skyrmions as information carriers in high-density storage devices, a method is needed that creates an intended number of skyrmions at specified places in the device preferably at a low energy cost. We theoretically propose that using a system with a fabricated hole or notch, the controlled creation of individual skyrmions can be achieved even when using an external magnetic field applied to the entire specimen. The fabricated defect turns out to work like a catalyst to reduce the energy barrier for the skyrmion creation.

  13. Effect of sample shape on nonlinear magnetization dynamics under an external magnetic field

    International Nuclear Information System (INIS)

    Vagin, Dmitry V.; Polyakov, Oleg P.

    2008-01-01

    Effect of sample shape on the nonlinear collective dynamics of magnetic moments in the presence of oscillating and constant external magnetic fields is studied using the Landau-Lifshitz-Gilbert (LLG) approach. The uniformly magnetized sample is considered to be an ellipsoidal axially symmetric particle described by demagnetization factors and uniaxial crystallographic anisotropy formed some angle with an applied field direction. It is investigated as to how the change in particle shape affects its nonlinear magnetization dynamics. To produce a regular study, all results are presented in the form of bifurcation diagrams for all sufficient dynamics regimes of the considered system. In this paper, we show that the sample's (particle's) shape and its orientation with respect to the external field (system configuration) determine the character of magnetization dynamics: deterministic behavior and appearance of chaotic states. A simple change in the system's configuration or in the shapes of its parts can transfer it from chaotic to periodic or even static regime and back. Moreover, the effect of magnetization precession stall and magnetic moments alignment parallel or antiparallel to the external oscillating field is revealed and the way of control of such 'polarized' states is found. Our results suggest that varying the particle's shape and fields' geometry may provide a useful way of magnetization dynamics control in complex magnetic systems

  14. Magnetization switching in ferromagnets by adsorbed chiral molecules without current or external magnetic field

    Science.gov (United States)

    Ben Dor, Oren; Yochelis, Shira; Radko, Anna; Vankayala, Kiran; Capua, Eyal; Capua, Amir; Yang, See-Hun; Baczewski, Lech Tomasz; Parkin, Stuart Stephen Papworth; Naaman, Ron; Paltiel, Yossi

    2017-02-01

    Ferromagnets are commonly magnetized by either external magnetic fields or spin polarized currents. The manipulation of magnetization by spin-current occurs through the spin-transfer-torque effect, which is applied, for example, in modern magnetoresistive random access memory. However, the current density required for the spin-transfer torque is of the order of 1 × 106 A.cm-2, or about 1 × 1025 electrons s-1 cm-2. This relatively high current density significantly affects the devices' structure and performance. Here we demonstrate magnetization switching of ferromagnetic thin layers that is induced solely by adsorption of chiral molecules. In this case, about 1013 electrons per cm2 are sufficient to induce magnetization reversal. The direction of the magnetization depends on the handedness of the adsorbed chiral molecules. Local magnetization switching is achieved by adsorbing a chiral self-assembled molecular monolayer on a gold-coated ferromagnetic layer with perpendicular magnetic anisotropy. These results present a simple low-power magnetization mechanism when operating at ambient conditions.

  15. The Effect of External Magnetic Field on Dielectric Permeability of Multiphase Ferrofluids

    Science.gov (United States)

    Dotsenko, O. A.; Pavlova, A. A.; Dotsenko, V. S.

    2018-03-01

    Nowadays, ferrofluids are applied in various fields of science and technology, namely space, medicine, geology, biology, automobile production, etc. In order to investigate the feasibility of applying ferrofluids in magnetic field sensors, the paper presents research into the influence of the external magnetic field on dielectric permeability of ferrofluids comprising magnetite nanopowder, multiwall carbon nanotubes, propanetriol and deionized water. The real and imaginary parts of the dielectric permeability change respectively by 3.7 and 0.5% when applying the magnetic field parallel to the electric. The findings suggest that the considered ferrofluid can be used as a magnetic level gauge or in design of variable capacitors.

  16. Self-Powered Nanocomposites under an External Rotating Magnetic Field for Noninvasive External Power Supply Electrical Stimulation.

    Science.gov (United States)

    Wu, Fengluan; Jin, Long; Zheng, Xiaotong; Yan, Bingyun; Tang, Pandeng; Yang, Huikai; Deng, Weili; Yang, Weiqing

    2017-11-08

    Electrical stimulation in biology and gene expression has attracted considerable attention in recent years. However, it is inconvenient that the electric stimulation needs to be supplied an implanted power-transported wire connecting the external power supply. Here, we fabricated a self-powered composite nanofiber (CNF) and developed an electric generating system to realize electrical stimulation based on the electromagnetic induction effect under an external rotating magnetic field. The self-powered CNFs generating an electric signal consist of modified MWNTs (m-MWNTs) coated Fe 3 O 4 /PCL fibers. Moreover, the output current of the nanocomposites can be increased due to the presence of the magnetic nanoparticles during an external magnetic field is applied. In this paper, these CNFs were employed to replace a bullfrog's sciatic nerve and to realize the effective functional electrical stimulation. The cytotoxicity assays and animal tests of the nanocomposites were also used to evaluate the biocompatibility and tissue integration. These results demonstrated that this self-powered CNF not only plays a role as power source but also can act as an external power supply under an external rotating magnetic field for noninvasive the replacement of injured nerve.

  17. Solitons in a Dielectric Medium under an External Magnetic Field

    OpenAIRE

    Isamu, NAKATA; Hiroaki, ONO; Mitito, YOSIDA; College of Integrated Arts and Sciences, University of Osaka Prefecture; Department of Mathematics and Physics, Faculty of Engineering, Setunan University; Nippondenso Co., Ltd.

    1993-01-01

    Solitons in a dielectric medium propagating along an external magnetic field is investigated. By means of a nonlinear perturbation method, the derivative nonlinear Schrodinger equation is derived and the possibility of propagation of the spiky and algebraic solitons is shown.

  18. Floating and flying ferrofluid bridges induced by external magnetic fields

    Science.gov (United States)

    Ma, Rongchao; Zhou, Yixin; Liu, Jing

    2015-04-01

    A ferrofluid is a mixture that exhibits both magnetism and fluidity. This merit enables the ferrofluid to be used in a wide variety of areas. Here we show that a floating ferrofluid bridge can be induced between two separated boards under a balanced external magnetic field generated by two magnets, while a flying ferrofluid bridge can be induced under an unbalanced external magnetic field generated by only one magnet. The mechanisms of the ferrofluid bridges were discussed and the corresponding mathematical equations were also established to describe the interacting magnetic force between the ferro particles inside the ferrofluid. This work answered a basic question that, except for the well-known floating water bridges that are related to electricity, one can also build up a liquid bridge that is related to magnetism.

  19. N{sub f}=1 QCD in external magnetic fields: staggered fermions

    Energy Technology Data Exchange (ETDEWEB)

    Cea, Paolo [INFN, Sezione di Bari, Via Amendola 173, I-70126 Bari (Italy); Dipartimento di Fisica dell’Università di Bari, Via Amendola 173, I-70126 Bari (Italy); Cosmai, Leonardo [INFN, Sezione di Bari, Via Amendola 173, I-70126 Bari (Italy)

    2015-12-10

    We investigate N{sub f}=1 QCD in external magnetic fields on the lattice. The background field is introduced by means of the so-called Schrödinger functional. We adopt standard staggered fermions with constant bare mass am=0.025 and magnetic fields with constant magnetic flux up to a{sup 2}eH≃2.3562. We find that the the deconfinement and chiral symmetry restoration temperatures do not depend on the strength of the applied magnetic field. Our method allow us to easily study the effects of the external magnetic fields on the QCD thermodynamics. We determine the influences of applied magnetic fields to the free energy, pressure, and equation of state of strongly interacting matter.

  20. Nonlinear dynamics of magnetic island interacting with external helical magnetic field

    International Nuclear Information System (INIS)

    Nishimura, S.; Yagi, M.; Itoh, S.-I.; Itoh, K.

    2009-01-01

    Full text: The control of magnetic islands is one of important issues for magnetically confined fusion plasmas. Magnetic islands strongly affect the achievable β''-value by modifying transports, equilibrium fields (i.e. radial profiles of electric current, pressure and electric field) and the stability of plasmas. The induction of resonant helical magnetic fields, which interact with magnetic islands, is an effective method to control the dynamics of magnetic islands. In the Large Helical Device (LHD), magnetic islands are excited by the external magnetic, and the generation of equilibrium poloidal E x B flows by magnetic islands is observed. On the other hand, the external helical magnetic fields have been used to control the poloidal rotation and the stability of magnetic islands in tokamak plasmas. The error field, which is caused by the misalignment of toroidal magnetic coil, plays a similar role to the external helical magnetic field. The locking of the rotation of magnetic islands by error field triggers the disruption in tokamak plasmas. Thus, it is important to understand the basic mechanism of the interaction between magnetic islands and external helical magnetic fields. In this study, nonlinear simulation of drift tearing mode is performed using a set of reduced two-fluid equations, and the detailed study of the interaction between magnetic islands with external helical magnetic fields is reported. The external helical field associated with magnetic islands is imposed by means of finite amplitude of perturbed magnetic flux (vector potential) at edge boundary. In our simulation, the locking (stop) of the rotation of magnetic islands is observed. The rotation of magnetic island is basically driven by the diamagnetic drift flow and E x B flow. It is found that contributions of these flows approximately cancel each other inside the separatrix of magnetic island in the locking phase. The detailed mechanism of the locking of magnetic island rotation is

  1. Separation of the Magnetic Field into External and Internal Parts

    DEFF Research Database (Denmark)

    Olsen, Nils; Glassmeier, K.-H.; Jia, X.

    2010-01-01

    The magnetic field of a planet or a planetary moon contains contributions from a variety of sources in the environment of the body (external sources) and its interior (internal sources). This chapter describes different methods that have been developed for the separation of external and internal...... source contributions, and their application to selected planets and one of Jupiter’s moons, Ganymede....

  2. Effects of externally applied Lorentz force on liquid metal flow

    Science.gov (United States)

    Fisher, Adam; Kolemen, Egemen; Hvasta, Mike

    2017-10-01

    This work looks at methods of controlling liquid metal flows using externally induced Lorentz forces. Large fusion reactors face an unsolved issue of heat fluxes at the divertor causing reactor damage. Fast-flowing liquid metal divertors can solve the heat flux problem, but to be viable there are various unfavorable flow phenomena that need to be suppressed and controlled. Some of those studied here are hydraulic jumps and surface waves. Externally induced Lorentz forces may be created by injecting electric currents into a liquid metal flow immersed within a magnetic field. Uniform Lorentz forces aligned with gravity work nearly analogously to changing gravity, and as such any flow features driven or affected by gravity may experience changes. As Lorentz force is dependent on current density which can be highly variant as cross-sectional flow depth changes, a non-uniform force field is created that is mostly unique to these types of flows; non-uniform magnetic fields yield similar effects. Lorentz force has been historically used as a driving force in pump applications, but little has been done in the way of flow control. The experiments in this work are galinstan channel flows that investigate the effects that Lorentz force has on hydraulic jump features and surface waves.

  3. External magnetic field configurations for EXTRAP

    International Nuclear Information System (INIS)

    Bonnevier, B.

    1982-08-01

    The strongly inhomogeneous magnetic field for stabilization of a pinch in an Extrap configuration can be created in various ways. Some possibilities both for the linear case and for the toroidal case are discussed. (author)

  4. Electron temperature control by an external magnetic field in solenoidal inductive discharge

    International Nuclear Information System (INIS)

    Lee, Min-Hyong; Ku, Ju-Hwan; Hwang, Kwang-Tae; Chung, Chin-Wook

    2009-01-01

    Electron temperature control is performed by controlling the external magnetic field strength in a solenoidal inductive discharge. As the magnetic field strength increases, the electron temperature of the plasma bulk decreases. The temperature at the discharge center falls from 3.1 to 1.5 eV when a 52 G dc magnetic field is applied. This decrease in the temperature is accompanied by a decrease in the plasma density. The change in temperature by the magnetic field is caused by both the electron confinement and the restriction of electron transport by the magnetic field in solenoidal inductive discharge.

  5. Foucault imaging and small-angle electron diffraction in controlled external magnetic fields.

    Science.gov (United States)

    Nakajima, Hiroshi; Kotani, Atsuhiro; Harada, Ken; Ishii, Yui; Mori, Shigeo

    2016-12-01

    We report a method for acquiring Foucault images and small-angle electron diffraction patterns in external magnetic fields using a conventional transmission electron microscope without any modification. In the electron optical system that we have constructed, external magnetic fields parallel to the optical axis can be controlled using the objective lens pole piece under weak excitation conditions in the Foucault mode and the diffraction mode. We observe two ferromagnetic perovskite-type manganese oxides, La 0.7 Sr 0.3 MnO 3 (LSMO) and Nd 0.5 Sr 0.5 MnO 3 , in order to visualize magnetic domains and their magnetic responses to external magnetic fields. In rhombohedral-structured LSMO, pinning of magnetic domain walls at crystallographic twin boundaries was found to have a strong influence on the generation of new magnetic domains in external applied magnetic fields. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Targeting of systemically-delivered magnetic nanoparticle hyperthermia using a noninvasive, static, external magnetic field

    Science.gov (United States)

    Zulauf, Grayson D.; Trembly, B. Stuart; Giustini, Andrew J.; Flint, Brian R.; Strawbridge, Rendall R.; Hoopes, P. Jack

    2013-01-01

    One of the greatest challenges of nanoparticle cancer therapy is the delivery of adequate numbers of nanoparticles to the tumor site. Iron oxide nanoparticles (IONPs) have many favorable qualities, including their nontoxic composition, the wide range of diameters in which they can be produced, the cell-specific cytotoxic heating that results from their absorption of energy from a nontoxic, external alternating magnetic field (AMF), and the wide variety of functional coatings that can be applied. Although IONPs can be delivered via an intra-tumoral injection to some tumors, the resulting tumor IONP distribution is generally inadequate; additionally, local tumor injections do not allow for the treatment of systemic or multifocal disease. Consequently, the ultimate success of nanoparticle based cancer therapy likely rests with successful systemic, tumor-targeted IONP delivery. In this study, we used a surface-based, bilateral, noninvasive static magnetic field gradient produced by neodymium-boron-iron magnets (80 T/m to 130 T/m in central plane between magnets), a rabbit ear model, and systemically-delivered starch-coated 100 nm magnetic (iron oxide) nanoparticles to demonstrate a spatially-defined increase in the local tissue accumulation of IONPs. In this non-tumor model, the IONPs remained within the local vascular space. It is anticipated that this technique can be used to enhance IONP delivery significantly to the tumor parenchyma/cells. PMID:24073325

  7. Diffusion of external magnetic fields into the cone-in-shell target in the fast ignition

    Science.gov (United States)

    Sunahara, Atsushi; Morita, Hiroki; Johzaki, Tomoyuki; Nagatomo, Hideo; Fujioka, Shinsuke; Hassanein, Ahmed; Firex Project Team

    2017-10-01

    We simulated the diffusion of externally applied magnetic fields into cone-in-shell target in the fast ignition. Recently, in the fast ignition scheme, the externally magnetic fields up to kilo-Tesla is used to guide fast electrons to the high-dense imploded core. In order to study the profile of the magnetic field, we have developed 2D cylindrical Maxwell equation solver with Ohm's law, and carried out simulations of diffusion of externally applied magnetic fields into a cone-in-shell target. We estimated the conductivity of the cone and shell target based on the assumption of Saha-ionization equilibrium. Also, we calculated the temporal evolution of the target temperature heated by the eddy current driven by temporal variation of magnetic fields, based on the accurate equation of state. Both, the diffusion of magnetic field and the increase of target temperature interact with each other. We present our results of temporal evolution of the magnetic field and its diffusion into the cone and shell target.

  8. Applying environmental externalities to US Clean Coal Technologies for Asia

    International Nuclear Information System (INIS)

    Szpunar, C.B.; Gillette, J.L.

    1993-01-01

    The United States is well positioned to play an expanding role in meeting the energy technology demands of the Asian Pacific Basin, including Indonesia, Thailand, and the Republic of China (ROC-Taiwan). The US Department of Energy Clean Coal Technology (CCT) Demonstration Program provides a proving ground for innovative coal-related technologies that can be applied domestically and abroad. These innovative US CCTs are expected to satisfy increasingly stringent environmental requirements while substantially improving power generation efficiencies. They should also provide distinct advantages over conventional pulverized coal-fired combustors. Finally, they are expected to be competitive with other energy options currently being considered in the region. This paper presents potential technology scenarios for Indonesia, Thailand, and the ROC-Taiwan and considers an environmental cost-benefit approach employing a newly developed method of applying environmental externalities. Results suggest that the economic benefits from increased emission control can indeed be quantified and used in cost-benefit comparisons, and that US CCTs can be very cost effective in reducing emissions

  9. Effects of external magnetic field on biodistribution of nanoparticles: A histological study

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tony [Department of Neurology, Chang Gung University College of Medicine and Memorial Hospital, 199 Tung-Hwa N Rd, Taipei, Taiwan (China); Hua, M.-Y. [Department of Chemical and Material Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan, Taiwan (China); Chen Jyhping [Department of Chemical and Material Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan, Taiwan (China); Wei, K.-C. [Department of Neurosurgery, Chang Gung University College of Medicine and Memorial Hospital, 199 Tung-Hwa N Rd, Taipei, Taiwan (China); Jung, S.-M. [Department of Pathology, Chang Gung University College of Medicine and Memorial Hospital, 199 Tung-Hwa N Rd, Taipei, Taiwan (China); Chang, Y.-J. [Department of Neurology, Chang Gung University College of Medicine and Memorial Hospital, 199 Tung-Hwa N Rd, Taipei, Taiwan (China); Jou, M.-J. [Department of Physiology and Pharmacology, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Ma, Y.-H. [Department of Physiology and Pharmacology, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China)]. E-mail: yhma@mail.cgu.edu.tw

    2007-04-15

    This study investigates the effect of external magnetic fields on the biodistribution of nanoparticles (NP). A NdFeB magnet of 2.4 kG was externally applied over the left femoral artery or right kidney. The 250 nm dextran-coated Fe{sub 3}O{sub 4} NP was injected via tail vein in healthy rats, and organs were taken 1 or 24 h later. Prussian blue stain revealed that NP were more rapidly retained in the liver and spleen than in the lungs. NP aggregation observed in the kidney and femoral artery after application of external magnets was time dependent. Hollow organs such as the intestine, colon, and urinary bladder retained little NP.

  10. Effects of external magnetic field on biodistribution of nanoparticles: A histological study

    International Nuclear Information System (INIS)

    Wu, Tony; Hua, M.-Y.; Chen Jyhping; Wei, K.-C.; Jung, S.-M.; Chang, Y.-J.; Jou, M.-J.; Ma, Y.-H.

    2007-01-01

    This study investigates the effect of external magnetic fields on the biodistribution of nanoparticles (NP). A NdFeB magnet of 2.4 kG was externally applied over the left femoral artery or right kidney. The 250 nm dextran-coated Fe 3 O 4 NP was injected via tail vein in healthy rats, and organs were taken 1 or 24 h later. Prussian blue stain revealed that NP were more rapidly retained in the liver and spleen than in the lungs. NP aggregation observed in the kidney and femoral artery after application of external magnets was time dependent. Hollow organs such as the intestine, colon, and urinary bladder retained little NP

  11. Magnetic structures in ultra-thin Holmium films: Influence of external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, L.J. [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, Natal 59600-900, RN (Brazil); Departamento de Física, Universidade do Estado do Rio Grande do Norte, Mossoró 59625-620, RN (Brazil); Mello, V.D. [Departamento de Física, Universidade do Estado do Rio Grande do Norte, Mossoró 59625-620, RN (Brazil); Anselmo, D.H.A.L. [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, Natal 59600-900, RN (Brazil); Vasconcelos, M.S., E-mail: mvasconcelos@ect.ufrn.br [Escola de Ciência e Tecnologia, Universidade Federal do Rio Grande do Norte, 59072-970 Natal, RN (Brazil)

    2015-03-01

    We address the magnetic phases in very thin Ho films at the temperature interval between 20 K and 132 K. We show that slab size, surface effects and magnetic field due to spin ordering impact significantly the magnetic phase diagram. Also we report that there is a relevant reduction of the external field strength required to saturate the magnetization and for ultra-thin films the helical state does not form. We explore the specific heat and the susceptibility as auxiliary tools to discuss the nature of the phase transitions, when in the presence of an external magnetic field and temperature effects. The presence of an external field gives rise to the magnetic phase Fan and the spin-slip structures. - Highlights: • We analyze the magnetic phases of very thin Ho films in the temperature interval 20–132 K. • We show that slab size, etc. due to spin ordering may impact the magnetic phase diagram. • All magnetic phase transitions, for strong magnetic fields, are marked by the specific heat. • The presence of an external field gives rise to the magnetic phase Fan and the spin-slip one.

  12. Motion behaviour of magneto-sensitive elastomers controlled by an external magnetic field for sensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Volkova, T.I., E-mail: tatiana.volkova@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Böhm, V., E-mail: valter.boehm@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Kaufhold, T., E-mail: tobias.kaufhold@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Popp, J., E-mail: jana.popp@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Becker, F., E-mail: felix.becker@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Borin, D.Yu., E-mail: dmitry.borin@tu-dresden.de [Technische Universität Dresden, Magnetofluiddynamics, Measuring and Automation Technology, D-01062 Dresden (Germany); Stepanov, G.V., E-mail: gstepanov@mail.ru [State Institute of Chemistry and Technology of Organoelement Compounds, 105118 Moscow (Russian Federation); Zimmermann, K., E-mail: klaus.zimmermann@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany)

    2017-06-01

    The development of sensor systems with a complex adaptive regulation of the operating sensitivity and behaviour is an actual scientific and technical challenge. Smart materials like magneto-sensitive elastomers (MSE) are seen as one potential solution for this problem, since their mechanical properties may be controlled by external magnetic fields. The present paper deals with the investigation of elastic and damping properties of MSE containing magnetically soft particles under the influence of a uniform magnetic field. Based on the measurement of the first eigenfrequency of free bending vibrations of a fixed beam, the effective Young's modulus is evaluated theoretically and also numerically using Finite Element Method. It is shown that this parameter, as well as the first eigenfrequency of the beam, increases monotonically with the magnitude of the applied magnetic field. The results are aimed to develop an acceleration sensor with adaptive magnetically controllable sensitivity range for the detection of external mechanical stimuli of the environment. - Highlights: • The motion behaviour of magneto-sensitive elastomers (MSE) with magnetically soft particles is investigated. • The first eigenfrequency of free bending vibrations of an MSE beam can be controlled by a uniform magnetic field. • Based on the experimental results, the effective Young's modulus of the system is evaluated theoretically and numerically. • The Young's modulus increases monotonically with the magnitude of the applied magnetic field. • The controlled mechanical compliance of MSE may be used for development of sensor systems with adaptive sensitivity range.

  13. Dynamics of molecular superrotors in an external magnetic field

    Science.gov (United States)

    Korobenko, Aleksey; Milner, Valery

    2015-08-01

    We excite diatomic oxygen and nitrogen to high rotational states with an optical centrifuge and study their dynamics in an external magnetic field. Ion imaging is employed to directly visualize, and follow in time, the rotation plane of the molecular superrotors. The two different mechanisms of interaction between the magnetic field and the molecular angular momentum in paramagnetic oxygen and non-magnetic nitrogen lead to qualitatively different behaviour. In nitrogen, we observe the precession of the molecular angular momentum around the field vector. In oxygen, strong spin-rotation coupling results in faster and richer dynamics, encompassing the splitting of the rotation plane into three separate components. As the centrifuged molecules evolve with no significant dispersion of the molecular wave function, the observed magnetic interaction presents an efficient mechanism for controlling the plane of molecular rotation.

  14. Dynamics of molecular superrotors in an external magnetic field

    International Nuclear Information System (INIS)

    Korobenko, Aleksey; Milner, Valery

    2015-01-01

    We excite diatomic oxygen and nitrogen to high rotational states with an optical centrifuge and study their dynamics in an external magnetic field. Ion imaging is employed to directly visualize, and follow in time, the rotation plane of the molecular superrotors. The two different mechanisms of interaction between the magnetic field and the molecular angular momentum in paramagnetic oxygen and non-magnetic nitrogen lead to qualitatively different behaviour. In nitrogen, we observe the precession of the molecular angular momentum around the field vector. In oxygen, strong spin–rotation coupling results in faster and richer dynamics, encompassing the splitting of the rotation plane into three separate components. As the centrifuged molecules evolve with no significant dispersion of the molecular wave function, the observed magnetic interaction presents an efficient mechanism for controlling the plane of molecular rotation. (paper)

  15. Fuel magnetization without external field coils (AutoMag)

    Science.gov (United States)

    Slutz, Stephen; Jennings, Christopher; Awe, Thomas; Shipley, Gabe; Lamppa, Derek; McBride, Ryan

    2016-10-01

    Magnetized Liner Inertial Fusion (MagLIF) has produced fusion-relevant plasma conditions on the Z accelerator where the fuel was magnetized using external field coils. We present a novel concept that does not need external field coils. This concept (AutoMag) magnetizes the fuel during the early part of the drive current by using a composite liner with helical conduction paths separated by insulating material. The drive is designed so the current rises slowly enough to avoid electrical breakdown of the insulators until a sufficiently strong magnetic field is established. Then the current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path and implode the liner. Low inductance magnetically insulated power feeds can be used with AutoMag to increase the drive current without interfering with diagnostic access. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  16. Handling magnetic anisotropy and magnetoimpedance effect in flexible multilayers under external stress

    Energy Technology Data Exchange (ETDEWEB)

    Agra, K.; Bohn, F. [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Mori, T.J.A. [Laboratório Nacional de Luz Síncrotron, Rua Giuseppe Máximo Scolfaro, 1000, Guará, 13083-100 Campinas, SP (Brazil); Callegari, G.L.; Dorneles, L.S. [Departamento de Física, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS (Brazil); Correa, M.A., E-mail: marciocorrea@dfte.ufrn.br [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)

    2016-12-15

    We investigate the dynamic magnetic response though magnetoimpedance effect of ferromagnetic flexible NiFe/Ta and FeCuNbSiB/Ta multilayers under external stress. We explore the possibility of handling magnetic anisotropy, and consequently the magnetoimpedance effect, of magnetostrictive multilayers deposited onto flexible substrates. We quantify the sensitivity of the multilayers under external stress by calculating the ratio between impedance variations and external stress changes, and show that considerable values can be reached by tuning the magnetic field, frequency, magnetostriction constant, and external stress. The results extend possibilities of application of magnetostrictive multilayers deposited onto flexible substrates when under external stress and place them as very attractive candidates as element sensor for the development of sensitive smart touch sensors. - Highlights: • We investigate the magnetoimpedance effect in magnetostrictive flexible multilayers grown on flexible substrates. • The external applied stress enables to tuning the samples anisotropies, and consequently the MI performance. • The flexible substrate becomes promising candidate for RF-frequency devices.

  17. Toroidal plasma reactor with low external magnetic field

    International Nuclear Information System (INIS)

    Beklemishev, A.D.; Khayrutdinov, R.R.; Petviashvili, V.I.; Tajima, T.; Gordin, V.A.; Tajima, T.

    1991-01-01

    A toroidal pinch configuration with safety factor q < 0.5 decreasing from the center to periphery without field reversal is proposed. This is capable of containing high pressure plasma with only small toroidal external magnetic field. Sufficient conditions for magnetohydrodynamic stability are fulfilled in this configuration. The stability is studied by constructing the Lyapunov functional and investigating its extrema both analytically and numerically. Comparison of the Lyapunov stability conditions with the conventional linear theory is carried out. Stable configurations are found with average β near 15%, with magnetic field associated mainly with plasma current. The β value calculated with the external magnetic field can be over 100%. Fast charged particles produced by fusion reactions are asymmetrically confined by the poloidal magnetic field (and due to the lack of strong toroidal field). They thus generate a current in the noncentral part of plasma to reinforce the poloidal field. This current drive can sustain the monotonic decrease of q with radius. 20 refs., 9 figs

  18. Reorientation response of magnetic microspheres attached to gold electrodes under an applied magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    De Los Santos Valladares, L.; Reeve, R.M.; Mitrelias, T.; Langford, R.M.; Barnes, C.H.W., E-mail: luis_d_v@hotmail.com [Cavendish Laboratory, Department of Physics, University of Cambridge Materials and Structures Laboratory (United Kingdom); Bustamante Dominguez, A. [Laboratorio de Ceramicos y Nanomateriales, Facultad de Ciencias Fisicas, Universidad Nacional Mayor de San Marcos, Lima (Peru); Aguiar, J. Albino [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Fisica; Azuma, Y. [Materials and Structures Laboratory, Tokyo Institute of Technology, Midori-ku, Yokohama (Japan); Majima, Y. [CREST, Japan Science and Technology Agency (JST), Midori-ku, Yokohama (Japan)

    2013-08-15

    In this work, we report the mechanical reorientation of thiolated ferromagnetic microspheres bridging a pair of gold electrodes under an external magnetic field. When an external magnetic field (7 kG) is applied during the measurement of the current-voltage characteristics of a carboxyl ferromagnetic microsphere (4 μm diameter) attached to two gold electrodes by self-assembled monolayers (SAMs) of octane dithiol (C{sub 8}H{sub 18}S{sub 2}), the current signal is distorted. Rather than due to magnetoresistance, this effect is caused by a mechanical reorientation of the ferromagnetic sphere, which alters the number of SAMs between the sphere and the electrodes and therefore affects conduction. To study the physical reorientation of the ferromagnetic particles, we measure their hysteresis loops while suspended in a liquid solution. (author)

  19. On the interaction between the external magnetic field and nanofluid inside a vertical square duct

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Kashif; Ahmad, Shabbir; Ahmad, Shahzad, E-mail: shahzadahmadbzu@gmail.com; Ashraf, Muhammad; Asif, Muhammad [Centre for Advanced Studies in Pure and Applied Mathematics, Bahauddin Zakariya University, Multan (Postal Code: 60800) (Pakistan)

    2015-10-15

    In this paper, we numerically study how the external magnetic field influences the flow and thermal characteristics of nanofluid inside a vertical square duct. The flow is considered to be laminar and hydrodynamically as well as thermally developed, whereas the thermal boundary condition of constant heat flux per unit axial length with constant peripheral temperature at any cross section, is assumed. The governing equations are solved using the spectral method and the finite difference method. Excellent comparison is noted in the numerical results given by the two methods but the spectral method is found to be superior in terms of both efficiency and accuracy. We have noted that the flow reversal due to high Raleigh number may be controlled by applying an external magnetic field of suitable strength. Moreover, the Nusselt number is found to be almost a linear function of the nanoparticle volume fraction parameter, for different values of the Raleigh number and the magnetic parameter.

  20. Manipulating Majorana zero modes on atomic rings with an external magnetic field

    Science.gov (United States)

    Li, Jian; Neupert, Titus; Bernevig, B. Andrei; Yazdani, Ali

    2016-01-01

    Non-Abelian quasiparticles have been predicted to exist in a variety of condensed matter systems. Their defining property is that an adiabatic braid between two of them results in a non-trivial change of the quantum state of the system. The simplest non-Abelian quasiparticles--the Majorana bound states--can occur in one-dimensional electronic nano-structures proximity-coupled to a bulk superconductor. Here we propose a set-up, based on chains of magnetic adatoms on the surface of a thin-film superconductor, in which the control over an externally applied magnetic field suffices to create and manipulate Majorana bound states. We consider specifically rings of adatoms and show that they allow for the creation, annihilation, adiabatic motion and braiding of pairs of Majorana bound states by varying the magnitude and orientation of the external magnetic field.

  1. On the interaction between the external magnetic field and nanofluid inside a vertical square duct

    Directory of Open Access Journals (Sweden)

    Kashif Ali

    2015-10-01

    Full Text Available In this paper, we numerically study how the external magnetic field influences the flow and thermal characteristics of nanofluid inside a vertical square duct. The flow is considered to be laminar and hydrodynamically as well as thermally developed, whereas the thermal boundary condition of constant heat flux per unit axial length with constant peripheral temperature at any cross section, is assumed. The governing equations are solved using the spectral method and the finite difference method. Excellent comparison is noted in the numerical results given by the two methods but the spectral method is found to be superior in terms of both efficiency and accuracy. We have noted that the flow reversal due to high Raleigh number may be controlled by applying an external magnetic field of suitable strength. Moreover, the Nusselt number is found to be almost a linear function of the nanoparticle volume fraction parameter, for different values of the Raleigh number and the magnetic parameter.

  2. Relabeling Internal and External Validity for Applied Social Scientists.

    Science.gov (United States)

    Campbell, Donald T.

    1986-01-01

    Confusion about the meaning of validity in quasi-experimental research can be addressed by carefully relabeling types of validity. Internal validity can more aptly be termed "local molar causal validity." More tentatively, the "principle of proximal similarity" can be substituted for the concept of external validity. (Author)

  3. Brushed permanent magnet DC MLC motor operation in an external magnetic field.

    Science.gov (United States)

    Yun, J; St Aubin, J; Rathee, S; Fallone, B G

    2010-05-01

    Linac-MR systems for real-time image-guided radiotherapy will utilize the multileaf collimators (MLCs) to perform conformal radiotherapy and tumor tracking. The MLCs would be exposed to the external fringe magnetic fields of the linac-MR hybrid systems. Therefore, an experimental investigation of the effect of an external magnetic field on the brushed permanent magnet DC motors used in some MLC systems was performed. The changes in motor speed and current were measured for varying external magnetic field strengths up to 2000 G generated by an EEV electromagnet. These changes in motor characteristics were measured for three orientations of the motor in the external magnetic field, mimicking changes in motor orientations due to installation and/or collimator rotations. In addition, the functionality of the associated magnetic motor encoder was tested. The tested motors are used with the Varian 120 leaf Millennium MLC (Maxon Motor half leaf and full leaf motors) and the Varian 52 leaf MKII MLC (MicroMo Electronics leaf motor) including a carriage motor (MicroMo Electronics). In most cases, the magnetic encoder of the motors failed prior to any damage to the gearbox or the permanent magnet motor itself. This sets an upper limit of the external magnetic field strength on the motor function. The measured limits of the external magnetic fields were found to vary by the motor type. The leaf motor used with a Varian 52 leaf MKII MLC system tolerated up to 450 +/- 10 G. The carriage motor tolerated up to 2000 +/- 10 G field. The motors used with the Varian 120 leaf Millennium MLC system were found to tolerate a maximum of 600 +/- 10 G. The current Varian MLC system motors can be used for real-time image-guided radiotherapy coupled to a linac-MR system, provided the fringe magnetic fields at their locations are below the determined tolerance levels. With the fringe magnetic fields of linac-MR systems expected to be larger than the tolerance levels determined, some form of

  4. External dacryocystorhinostomy combined with mucosal grafting and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Uehara, Fumiyuki; Ohba, Norio

    2002-01-01

    The purpose of this study was to facilitate understanding of the use of magnetic resonance imaging (MRI) in nasolacrimal obstructive diseases and to determine the indication for external dacryocystorhinostomy (DCR) combined with mucosal grafting. We retrospectively studied the correlation between MRI images and surgical findings in 13 consecutive patients with swollen lacrimal sacs because of obstruction of the nasolacrimal duct or lacrimal sac. They were treated at the Kagoshima University Hospital between June 1999 and May 2001. A simple procedure of external DCR was performed in 9 cases, and a procedure combined with mucosal grafting was performed in 4 cases (age range, 51-88 years). Surgical findings in the fibrous region of the lacrimal sac corresponded to the hyperintense signal on MRI T 1 -weighted (T1W) images, more remarkably after enhancement. Surgical findings in the granulomatous sac and proteinaceous contents corresponded to the isointense areas on T2W images. Cases with thin sac were treated by standard DCR, whereas cases with tick, fibrous and granulomatous sac were treated by external DCR combined with mucosal grafting. The MRI images provide a useful preoperative determination for indications of external DCR combined with mucosal grafting. (author)

  5. Deflection modeling of permanent magnet spherical chains in the presence of external magnetic fields

    International Nuclear Information System (INIS)

    O'Donoghue, Kilian; Cantillon-Murphy, Pádraig

    2013-01-01

    This work examines the interaction of permanently magnetised spheres in the presence of external magnetic fields at the millimetre scale. Static chain formation and deflection models are described for N spheres in the presence of an external magnetic field. Analytical models are presented for the two sphere case by neglecting the effects of magnetocrystalline anisotropy while details of a numerical approach to solve a chain of N spheres are shown. The model is experimentally validated using chain deflections in 4.5 mm diameter spheres in groups of 2, 3 and 4 magnets in the presence of uniform magnetic fields, neglecting gravitational effects, with good agreement between the theoretical model and experimental results. This spherical chain structure could be used as an end effector for catheters as a deflection mechanism for magnetic guidance. The spherical point contacts result in large deflections for navigation around tight corners in endoluminal minimally invasive clinical applications. - Highlights: • We model the interaction of magnetic spheres with uniform external fields. • Analytical models are presented for two spheres interacting with an external field. • Numerical methods are used to model the interaction of N spheres in chain formations. • These models are tested experimentally. • We report good agreement between experiment and theory

  6. Applied physics of external radiation exposure dosimetry and radiation protection

    CERN Document Server

    Antoni, Rodolphe

    2017-01-01

    This book describes the interaction of living matter with photons, neutrons, charged particles, electrons and ions. The authors are specialists in the field of radiation protection. The book synthesizes many years of experiments with external radiation exposure in the fields of dosimetry and radiation shielding in medical, industrial and research fields. It presents the basic physical concepts including dosimetry and offers a number of tools to be used by students, engineers and technicians to assess the radiological risk and the means to avoid them by calculating the appropriate shields. The theory of radiation interaction in matter is presented together with empirical formulas and abacus. Numerous numerical applications are treated to illustrate the different topics. The state of the art in radiation protection and dosimetry is presented in detail, especially in the field of simulation codes for external exposure to radiation, medical projects and advanced research. Moreover, important data spread in differ...

  7. Modeling external constraints: Applying expert systems to nuclear plants

    International Nuclear Information System (INIS)

    Beck, C.E.; Behera, A.K.

    1993-01-01

    Artificial Intelligence (AI) applications in nuclear plants have received much attention over the past decade. Specific applications that have been addressed include development of models and knowledge-bases, plant maintenance, operations, procedural guidance, risk assessment, and design tools. This paper examines the issue of external constraints, with a focus on the use of Al and expert systems as design tools. It also provides several suggested methods for addressing these constraints within the Al framework. These methods include a State Matrix scheme, a layered structure for the knowledge base, and application of the dynamic parameter concept

  8. Tailoring of in-plane magnetic anisotropy in polycrystalline cobalt thin films by external stress

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Dileep, E-mail: dkumar@csr.res.in [UGC-DAE Consortium for Scientic Research, Khandwa Road, Indore 452001 (India); Singh, Sadhana [UGC-DAE Consortium for Scientic Research, Khandwa Road, Indore 452001 (India); Vishawakarma, Pramod [School of Nanotechnology, RGPV, Bhopal 462036 (India); Dev, Arun Singh; Reddy, V.R. [UGC-DAE Consortium for Scientic Research, Khandwa Road, Indore 452001 (India); Gupta, Ajay [Amity Center for Spintronic Materials, Amity University, Sector 125, Noida 201303 (India)

    2016-11-15

    Polycrystalline Co films of nominal thickness ~180 Å were deposited on intentionally curved Si substrates. Tensile and compressive stresses of 100 MPa and 150 MPa were induced in the films by relieving the curvature. It has been found that, within the elastic limit, presence of stress leads to an in-plane magnetic anisotropy in the film and its strength increases with increasing stress. Easy axis of magnetization in the films is found to be parallel/ transverse to the compressive /tensile stresses respectively. The origin of magnetic anisotropy in the stressed films is understood in terms of magneto- elastic coupling, where the stress try to align the magnetic moments in order to minimize the magneto-elastic as well as anisotropy energy. Tensile stress is also found to be responsible for the surface smoothening of the films, which is attributed to the movement of the atoms associated with the applied stress. The present work provides a possible way to tailor the magnetic anisotropy and its direction in polycrystalline and amorphous films using external stress. - Highlights: • Tensile and compressive stresses were induced in Co films by removing the bending force from the substrates after film deposition. • Controlled external mechanical stress is found to be responsible for magnetic anisotropies in amorphous and polycrystalline thin films, where crystalline anisotropy is absent. • Tensile stress leads to surface smoothening of the polycrystalline Co films.

  9. Tailoring of in-plane magnetic anisotropy in polycrystalline cobalt thin films by external stress

    International Nuclear Information System (INIS)

    Kumar, Dileep; Singh, Sadhana; Vishawakarma, Pramod; Dev, Arun Singh; Reddy, V.R.; Gupta, Ajay

    2016-01-01

    Polycrystalline Co films of nominal thickness ~180 Å were deposited on intentionally curved Si substrates. Tensile and compressive stresses of 100 MPa and 150 MPa were induced in the films by relieving the curvature. It has been found that, within the elastic limit, presence of stress leads to an in-plane magnetic anisotropy in the film and its strength increases with increasing stress. Easy axis of magnetization in the films is found to be parallel/ transverse to the compressive /tensile stresses respectively. The origin of magnetic anisotropy in the stressed films is understood in terms of magneto- elastic coupling, where the stress try to align the magnetic moments in order to minimize the magneto-elastic as well as anisotropy energy. Tensile stress is also found to be responsible for the surface smoothening of the films, which is attributed to the movement of the atoms associated with the applied stress. The present work provides a possible way to tailor the magnetic anisotropy and its direction in polycrystalline and amorphous films using external stress. - Highlights: • Tensile and compressive stresses were induced in Co films by removing the bending force from the substrates after film deposition. • Controlled external mechanical stress is found to be responsible for magnetic anisotropies in amorphous and polycrystalline thin films, where crystalline anisotropy is absent. • Tensile stress leads to surface smoothening of the polycrystalline Co films.

  10. Effect of forming process by using external magnetic field of bonded magnet made from NdFeB flakes to microstructure and magnetic properties

    Science.gov (United States)

    Suprapedi; Sardjono, P.; Muljadi; Djauhari, N. R.; Ramlan

    2018-03-01

    Research of fabricated bonded magnets NdFeB made from NdFeB flakes with variation of external magnetic field has been done. The materials preparation process begins with milling NdFeB flakes using High Energy Milling (HEM) for 60 minutes and mixing it with 5 wt % celuna binder and performing compaction to form pellet with a pressure of 40 Kgf/cm2 and then applying external magnetic field (0, 2000, 5000, 8000 and 11000 Gauss). The pellet samples were then dried using vacuum dryer with temperature of 100 °C for 1 hour. Characterization includes bulk density, measurement of magnetic properties with gauss meter, and Vibrating Sample Magnetometer (VSM). From the characterization results the best value was obtained on the external magnetic field orientation of 8000 to 11000 Gauss with a density value of 5.38 g/cm3, flux magnetic value of 465.9 – 467.1 Gauss, remanence value of 2.63–2.776 kGauss, and coercivity value of 1.905–1.925 kOe.

  11. Towards a beyond 1 GHz solid-state nuclear magnetic resonance: External lock operation in an external current mode for a 500 MHz nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Takahashi, Masato; Maeda, Hideaki; Ebisawa, Yusuke; Tennmei, Konosuke; Yanagisawa, Yoshinori; Nakagome, Hideki; Hosono, Masami; Takasugi, Kenji; Hase, Takashi; Miyazaki, Takayoshi; Fujito, Teruaki; Kiyoshi, Tsukasa; Yamazaki, Toshio

    2012-01-01

    Achieving a higher magnetic field is important for solid-state nuclear magnetic resonance (NMR). But a conventional low temperature superconducting (LTS) magnet cannot exceed 1 GHz (23.5 T) due to the critical magnetic field. Thus, we started a project to replace the Nb 3 Sn innermost coil of an existing 920 MHz NMR (21.6 T) with a Bi-2223 high temperature superconducting (HTS) innermost coil. Unfortunately, the HTS magnet cannot be operated in persistent current mode; an external dc power supply is required to operate the NMR magnet, causing magnetic field fluctuations. These fluctuations can be stabilized by a field-frequency lock system based on an external NMR detection coil. We demonstrate here such a field-frequency lock system in a 500 MHz LTS NMR magnet operated in an external current mode. The system uses a 7 Li sample in a microcoil as external NMR detection system. The required field compensation is calculated from the frequency of the FID as measured with a frequency counter. The system detects the FID signal, determining the FID frequency, and calculates the required compensation coil current to stabilize the sample magnetic field. The magnetic field was stabilized at 0.05 ppm/3 h for magnetic field fluctuations of around 10 ppm. This method is especially effective for a magnet with large magnetic field fluctuations. The magnetic field of the compensation coil is relatively inhomogeneous in these cases and the inhomogeneity of the compensation coil can be taken into account.

  12. The enhancement of the magnetic properties of α-Fe{sub 2}O{sub 3} nanocatalyst using an external magnetic field for the production of green ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Alqasem, Bilal, E-mail: bilalalqasem@yahoo.com; Yahya, Noorhana, E-mail: noorhana_yahya@petronas.com.my; Qureshi, Saima, E-mail: saima_qureshi_25@yahoo.com; Irfan, Muhammad, E-mail: irfan-mohammad@hotmail.com; Ur Rehman, Zia, E-mail: zia545@hotmail.com; Soleimani, Hassan, E-mail: hassan.soleimani@petronas.com.my

    2017-03-15

    Highlights: • External magnetic field was applied during syntheses of α-Fe{sub 2}O{sub 3} nanocatalyst. • α-Fe{sub 2}O{sub 3} nanocatalyst with enhanced magnetic properties was synthesized. • Effect of magnetic properties and morphology of α-Fe{sub 2}O{sub 3} on ammonia yield was tested. • α-Fe{sub 2}O{sub 3} nanowires with improved saturation magnetization created high ammonia yield. • A maximum green ammonia yield of 24.174 × 10{sup −3} mol h{sup −1} g cat{sup −1} was produced. - Abstract: Hematite nanocatalysts with improved magnetic properties were synthesized using electrical resistive heating under the presence of a magnetic field and a gaseous environment containing oxygen and nitrogen. The synthesis temperature was varied from 500–850 °C in the absence and presence of a static magnetic field of 0.25 T. VSM hysteresis results showed that there is a clear improve in the magnetic properties of the nanocatalysts when an external magnetic field was used during the synthesis. It also showed that the nanowires amongst other shapes hold the highest saturation magnetization value. The produced α-Fe{sub 2}O{sub 3} nanocatalysts were used for ammonia synthesis under an external magnetic field strength ranging between 0.4–2 T. Correspondingly, (24.174 mmol h{sup −1} g cat{sup −1}) ammonia was yielded by applying an external magnetic field of 1.2 T and using the α-Fe{sub 2}O{sub 3} nanowires synthesized at 700 °C with the highest saturation magnetization value of 189.43 emu/g.

  13. Relativistic Killingbeck energy states under external magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Eshghi, M. [Islamic Azad University, Researchers and Elite Club, Central Tehran Branch, Tehran (Iran, Islamic Republic of); Mehraban, H. [Semnan University, Faculty of Physics, Semnan (Iran, Islamic Republic of); Ikhdair, S.M. [An-Najah National University, Department of Physics, Faculty of Science, Nablus, West Bank, Palestine (Country Unknown); Near East University, Department of Electrical Engineering, Nicosia, Northern Cyprus (Turkey)

    2016-07-15

    We address the behavior of the Dirac equation with the Killingbeck radial potential including the external magnetic and Aharonov-Bohm (AB) flux fields. The spin and pseudo-spin symmetries are considered. The correct bound state spectra and their corresponding wave functions are obtained. We seek such a solution using the biconfluent Heun's differential equation method. Further, we give some of our results at the end of this study. Our final results can be reduced to their non-relativistic forms by simply using some appropriate transformations. The spectra, in the spin and pseudo-spin symmetries, are very similar with a slight difference in energy spacing between different states. (orig.)

  14. Relativistic Killingbeck energy states under external magnetic fields

    International Nuclear Information System (INIS)

    Eshghi, M.; Mehraban, H.; Ikhdair, S.M.

    2016-01-01

    We address the behavior of the Dirac equation with the Killingbeck radial potential including the external magnetic and Aharonov-Bohm (AB) flux fields. The spin and pseudo-spin symmetries are considered. The correct bound state spectra and their corresponding wave functions are obtained. We seek such a solution using the biconfluent Heun's differential equation method. Further, we give some of our results at the end of this study. Our final results can be reduced to their non-relativistic forms by simply using some appropriate transformations. The spectra, in the spin and pseudo-spin symmetries, are very similar with a slight difference in energy spacing between different states. (orig.)

  15. Identification of the plasma magnetic contour from external magnetic measurements by means of equivalent currents

    International Nuclear Information System (INIS)

    Bettini, P.; Bellina, F.; Stella, A.; Trevisan, F.; Formisano, A.; Martone, R.

    2001-01-01

    One of the main research issues in the thermonuclear fusion area is the identification of plasma contour starting from external magnetic measurements. Possible approaches to this inverse problem make use of equivalent currents to represent the plasma internal current density, regularizing in this way the magnetic field reconstruction. Of course, the choice of the representation basis for such equivalent currents is critical. The paper aims at analyzing the effect of the number and position of base currents on the performance of the identification algorithm. (orig.)

  16. Effects of neutral distribution and external magnetic field on plasma momentum in electrodeless plasma thrusters

    Science.gov (United States)

    Takase, Kazuki; Takahashi, Kazunori; Takao, Yoshinori

    2018-02-01

    The effects of neutral distribution and an external magnetic field on plasma distribution and thruster performance are numerically investigated using a particle-in-cell simulation with Monte Carlo collisions (PIC-MCC) and the direct simulation Monte Carlo (DSMC) method. The modeled thruster consists of a quartz tube 1 cm in diameter and 3 cm in length, where a double-turn rf loop antenna is wound at the center of the tube and a solenoid is placed between the loop antenna and the downstream tube exit. A xenon propellant is introduced from both the upstream and downstream sides of the thruster, and the flow rates are varied while maintaining the total gas flow rate of 30 μg/s. The PIC-MCC calculations have been conducted using the neutral distribution obtained from the DSMC calculations, which were applied with different strengths of the magnetic field. The numerical results show that both the downstream gas injection and the external magnetic field with a maximum strength near the thruster exit lead to a shift of the plasma density peak from the upstream to the downstream side. Consequently, a larger total thrust is obtained when increasing the downstream gas injection and the magnetic field strength, which qualitatively agrees with a previous experiment using a helicon plasma source.

  17. Influence of magnetization on the applied magnetic field in various AMR regenerators

    DEFF Research Database (Denmark)

    Mira, A.; de Larochelambert, T.; Espanet, C.

    2017-01-01

    The aim of this work is to assess the influence of a magnetic sample on the applied magnetic field inside the air gap of a magnetic circuit. Different magnetic sources including an electromagnet, a permanent magnet in a soft ferromagnetic toroidal yoke, as well as 2D and 3D Halbach cylinders...

  18. Modeling of mechanisms responsible for ELM mitigation by external magnetic field perturbations

    International Nuclear Information System (INIS)

    Tokar, M.Z.; Rogister, A.L.; Wolf, R.C.; Singh, R.; Kaw, P.

    2007-01-01

    Edge-Localized Modes (ELMs) is an intrinsic feature of the high confinement H-mode in tokamaks. On the one hand, they are beneficial for stationary discharge performance by expelling from the plasma impurities produced at the machine walls. On the other hand, under reactor conditions type I ELMs would themselves lead to a dramatic increase of impurity release and cause very large pulse heat loads on divertor plates. Therefore, it is crucial to find a way to mitigate ELMs without negative consequences for the plasma. Recent experiments on the tokamak D-III D have demonstrated that by applying resonant magnetic field perturbations from external coils, large type I ELMs can be effectively mitigated without any significant loss of confinement quality. This mode of operation is highly desirable for future fusion reactors and therefore it is very important to achieve an understanding of physical mechanism leading to ELMs suppression through external field perturbations. In the present contribution ballooning-pealing MHD instability considered normally as the main cause of the edge localized modes of type I, is theoretically examined in the presence of external magnetic field perturbations by applying a mode-mode coupling technique. It is demonstrated that through non-linear interaction, leading to the generation of side bands which suck energy from the main mode, such perturbations can raise the threshold of MHD instabilities. The synergy of this effect with the influence of external perturbations on the particle and energy transport in the edge transport barrier is studied by applying a simple model for the time variation of plasma parameters in the edge transport barrier. It is demonstrated that this synergy can be very beneficial for the plasma performance. In future experiments on JET and ITER it may lead to a noticeable increase of the pedestal pressure compared to the standard H-mode operation. (author)

  19. Precise position control of a helical magnetic robot in pulsatile flow using the rotating frequency of the external magnetic field

    Directory of Open Access Journals (Sweden)

    Jongyul Kim

    2017-05-01

    Full Text Available We propose a position control method for a helical magnetic robot (HMR that uses the rotating frequency of the external rotating magnetic field (ERMF to minimize the position fluctuation of the HMR caused by pulsatile flow in human blood vessels. We prototyped the HMR and conducted several experiments in pseudo blood vessel environments with a peristaltic pump. We experimentally obtained the relation between the flow rate and the rotating frequency of the ERMF required to make the HMR stationary in a given pulsatile flow. Then we approximated the pulsatile flow by Fourier series and applied the required ERMF rotating frequency to the HMR in real time. Our proposed position control method drastically reduced the position fluctuation of the HMR under pulsatile flow.

  20. Self-field loss of BSCCOrAg tape in external AC magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; ten Haken, Bernard; Gömöry, F.; ten Kate, Herman H.J.

    1998-01-01

    The self-field loss of BSCCOrAg tapes has been measured in combination with an external AC magnetic field. This situation occurs when conductors are used in applications such as coils or cables. An increase of the self-field loss due to external AC magnetic field is observed. An increase of the

  1. Mitigating stimulated scattering processes in gas-filled Hohlraums via external magnetic fields

    Science.gov (United States)

    Gong, Tao; Zheng, Jian; Li, Zhichao; Ding, Yongkun; Yang, Dong; Hu, Guangyue; Zhao, Bin

    2015-09-01

    A simple model, based on energy and pressure equilibrium, is proposed to deal with the effect of external magnetic fields on the plasma parameters inside the laser path, which shows that the electron temperature can be significantly enhanced as the intensity of the external magnetic fields increases. With the combination of this model and a 1D three-wave coupling code, the effect of external magnetic fields on the reflectivities of stimulated scattering processes is studied. The results indicate that a magnetic field with an intensity of tens of Tesla can decrease the reflectivities of stimulated scattering processes by several orders of magnitude.

  2. Influence of External Magnetic Fields on Tunneling of Spin-1 Bose Condensate

    International Nuclear Information System (INIS)

    Yu Zhaoxian; Jiao Zhiyong; Sun Jinzuo

    2005-01-01

    In this letter, we have studied the influence of the external magnetic fields on tunneling of the spin-1 Bose condensate. We find that the population transfer between spin-0 and spin-±1 exhibits the step structure under the external cosinusoidal magnetic field and a combination of static and cosinusoidal one, respectively. Compared with the longitudinal component of the external magnetic field, the smaller the transverse component of the magnetic field is, the larger the time scale of exhibiting the step structure does. The tunneling current may exhibit periodically oscillation behavior when the ratio of the transverse component of the magnetic field is smaller than that of the longitudinal component, otherwise it exhibits a damply oscillating behavior. This means that the dynamical spin localization can be adjusted by the external magnetic fields.

  3. Transpermeance Amplifier Applied to Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Jossana Ferreira

    2017-02-01

    Full Text Available The most conventional approach of controlling magnetic forces in active magnetic bearings (AMBs is through current feedback amplifiers: transconductance. This enables the operation of the AMB to be understood in terms of a relatively simple current-based model as has been widely reported on in the literature. The alternative notion of using transpermeance amplifiers, which approximate the feedback of gap flux rather than current, has been in commercial use in some form for at least thirty years, however is only recently seeing more widespread acceptance as a commercial standard. This study explores how such alternative amplifiers should be modeled and then examines the differences in behavior between AMBs equipped with transconductance and transpermeance amplifiers. The focus of this study is on two aspects. The first is the influence of rotor displacement on AMB force, commonly modeled as a constant negative equivalent mechanical stiffness, and it is shown that either scheme actually leads to a finite bandwidth effect, but that this bandwidth is much lower when transpermeance is employed. The second aspect is the influence of eddy currents. Using a very simple model of eddy currents (a secondary short-circuited coil, it is demonstrated that transpermeance amplifiers can recover significant actuator bandwidth compared with transconductance, but at the cost of needing increased peak current headroom.

  4. Influence of nonuniform external magnetic fields and anode--cathode shaping on magnetic insulation in coaxial transmission lines

    International Nuclear Information System (INIS)

    Mostrom, M.A.

    1979-01-01

    Coaxial transmission lines, used to transfer the high voltage pulse into the diode region of a relativistic electron beam generator, have been studied using the two-dimensional time-dependent fully relativistic and electromagnetic particle simulation code CCUBE. A simple theory of magnetic insulation that agrees well with simulation results for a straight cylindrical coax in a uniform external magnetic field is used to interpret the effects of anode--cathode shaping and nonuniform external magnetic fields. Loss of magnetic insulation appears to be minimized by satisfying two conditions: (1) the cathode surface should follow a flux surface of the external magnetic field; (2) the anode should then be shaped to insure that the magnetic insulation impedance, including transients, is always greater than the effective load impedance wherever there is an electron flow in the anode--cathode gap

  5. Applying torque to the Escherichia coli flagellar motor using magnetic tweezers.

    Science.gov (United States)

    van Oene, Maarten M; Dickinson, Laura E; Cross, Bronwen; Pedaci, Francesco; Lipfert, Jan; Dekker, Nynke H

    2017-03-07

    The bacterial flagellar motor of Escherichia coli is a nanoscale rotary engine essential for bacterial propulsion. Studies on the power output of single motors rely on the measurement of motor torque and rotation under external load. Here, we investigate the use of magnetic tweezers, which in principle allow the application and active control of a calibrated load torque, to study single flagellar motors in Escherichia coli. We manipulate the external load on the motor by adjusting the magnetic field experienced by a magnetic bead linked to the motor, and we probe the motor's response. A simple model describes the average motor speed over the entire range of applied fields. We extract the motor torque at stall and find it to be similar to the motor torque at drag-limited speed. In addition, use of the magnetic tweezers allows us to force motor rotation in both forward and backward directions. We monitor the motor's performance before and after periods of forced rotation and observe no destructive effects on the motor. Our experiments show how magnetic tweezers can provide active and fast control of the external load while also exposing remaining challenges in calibration. Through their non-invasive character and straightforward parallelization, magnetic tweezers provide an attractive platform to study nanoscale rotary motors at the single-motor level.

  6. Applying torque to the Escherichia coli flagellar motor using magnetic tweezers

    Science.gov (United States)

    van Oene, Maarten M.; Dickinson, Laura E.; Cross, Bronwen; Pedaci, Francesco; Lipfert, Jan; Dekker, Nynke H.

    2017-01-01

    The bacterial flagellar motor of Escherichia coli is a nanoscale rotary engine essential for bacterial propulsion. Studies on the power output of single motors rely on the measurement of motor torque and rotation under external load. Here, we investigate the use of magnetic tweezers, which in principle allow the application and active control of a calibrated load torque, to study single flagellar motors in Escherichia coli. We manipulate the external load on the motor by adjusting the magnetic field experienced by a magnetic bead linked to the motor, and we probe the motor’s response. A simple model describes the average motor speed over the entire range of applied fields. We extract the motor torque at stall and find it to be similar to the motor torque at drag-limited speed. In addition, use of the magnetic tweezers allows us to force motor rotation in both forward and backward directions. We monitor the motor’s performance before and after periods of forced rotation and observe no destructive effects on the motor. Our experiments show how magnetic tweezers can provide active and fast control of the external load while also exposing remaining challenges in calibration. Through their non-invasive character and straightforward parallelization, magnetic tweezers provide an attractive platform to study nanoscale rotary motors at the single-motor level. PMID:28266562

  7. Spin-lattice dynamics simulation of external field effect on magnetic order of ferromagnetic iron

    International Nuclear Information System (INIS)

    Chui, C. P.; Zhou, Yan

    2014-01-01

    Modeling of field-induced magnetization in ferromagnetic materials has been an active topic in the last dozen years, yet a dynamic treatment of distance-dependent exchange integral has been lacking. In view of that, we employ spin-lattice dynamics (SLD) simulations to study the external field effect on magnetic order of ferromagnetic iron. Our results show that an external field can increase the inflection point of the temperature. Also the model provides a better description of the effect of spin correlation in response to an external field than the mean-field theory. An external field has a more prominent effect on the long range magnetic order than on the short range counterpart. Furthermore, an external field allows the magnon dispersion curves and the uniform precession modes to exhibit magnetic order variation from their temperature dependence

  8. Complementary analyses of hollow cylindrical unioriented permanent magnet (HCM) with high permeability external layer.

    Science.gov (United States)

    Lobo, Carlos M S; Tosin, Giancarlo; Baader, Johann E; Colnago, Luiz A

    2017-10-01

    In this article, several studies based on analytical expressions and computational simulations on Hollow Cylindrical Magnets with an external soft ferromagnetic material (HCM magnets) are presented. Electromagnetic configurations, as well as permanent-magnet-based structures, are studied in terms of magnetic field strength and homogeneity. Permanent-magnet-based structures are further analyzed in terms of the anisotropy of the magnetic permeability. It was found that the HCM magnets produce a highly homogeneous magnetic field as long as the magnetic material is isotropic. The dependency of the magnetic field strength and homogeneity in terms of the anisotropy of the magnetic permeability is also explored here. These magnets can potentially be used in medium-resolution NMR spectrometers and high-field NMR spectrometers. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Anisotropic diffusion across an external magnetic field and large-scale fluctuations in magnetized plasmas.

    Science.gov (United States)

    Holod, I; Zagorodny, A; Weiland, J

    2005-04-01

    The problem of random motion of charged particles in an external magnetic field is studied under the assumption that the Langevin sources produce anisotropic diffusion in velocity space and the friction force is dependent on the direction of particle motion. It is shown that in the case under consideration, the kinetic equation describing particle transitions in phase space is reduced to the equation with a Fokker-Planck collision term in the general form (non-isotropic friction coefficient and nonzero off-diagonal elements of the diffusion tensor in the velocity space). The solution of such an equation has been obtained and the explicit form of the transition probability is found. Using the obtained transition probability, the mean-square particle displacements in configuration and velocity space were calculated and compared with the results of numerical simulations, showing good agreement. The obtained results are used to generalize the theory of large-scale fluctuations in plasmas to the case of anisotropic diffusion across an external magnetic field. Such diffusion is expected to be observed in the case of an anisotropic k spectrum of fluctuations generating random particle motion (for example, in the case of drift-wave turbulence).

  10. Topology optimized and 3D printed polymer-bonded permanent magnets for a predefined external field

    Science.gov (United States)

    Huber, C.; Abert, C.; Bruckner, F.; Pfaff, C.; Kriwet, J.; Groenefeld, M.; Teliban, I.; Vogler, C.; Suess, D.

    2017-08-01

    Topology optimization offers great opportunities to design permanent magnetic systems that have specific external field characteristics. Additive manufacturing of polymer-bonded magnets with an end-user 3D printer can be used to manufacture permanent magnets with structures that had been difficult or impossible to manufacture previously. This work combines these two powerful methods to design and manufacture permanent magnetic systems with specific properties. The topology optimization framework is simple, fast, and accurate. It can also be used for the reverse engineering of permanent magnets in order to find the topology from field measurements. Furthermore, a magnetic system that generates a linear external field above the magnet is presented. With a volume constraint, the amount of magnetic material can be minimized without losing performance. Simulations and measurements of the printed systems show very good agreement.

  11. Trajectory control of PbSe–γ-Fe2O3 nanoplatforms under viscous flow and an external magnetic field

    Science.gov (United States)

    Etgar, Lioz; Nakhmani, Arie; Tannenbaum, Allen; Lifshitz, Efrat; Tannenbaum, Rina

    2010-01-01

    The flow behavior of nanostructure clusters, consisting of chemically bonded PbSe quantum dots and magnetic γ -Fe2O3 nanoparticles, has been investigated. The clusters are regarded as model nanoplatforms with multiple functionalities, where the γ -Fe2O3 magnets serve as transport vehicles, manipulated by an external magnetic field gradient, and the quantum dots act as fluorescence tags within an optical window in the near-infrared regime. The clusters’ flow was characterized by visualizing their trajectories within a viscous fluid (mimicking a blood stream), using an optical imaging method, while the trajectory pictures were analyzed by a specially developed processing package. The trajectories were examined under various flow rates, viscosities and applied magnetic field strengths. The results revealed a control of the trajectories even at low magnetic fields (medicine. PMID:20368678

  12. Moessbauer study of epsilon-Fe under an external magnetic field

    CERN Document Server

    Nasu, S; Kawakami, T; Tsutsui, T; Endo, S

    2002-01-01

    Using a diamond anvil cell, sup 5 sup 7 Fe Moessbauer measurements of the high-pressure phase of iron, epsilon-Fe at 20 GPa, have been performed at 4.5 K under external magnetic fields up to 7 T. The magnitudes of the hyperfine magnetic fields depend linearly on the external magnetic fields, H sub e sub x sub t. This implies that there is no induced hyperfine field due to the local magnetic moment and epsilon-Fe under 20 GPa at 4.5 K is determined as a Pauli paramagnet.

  13. Theoretical analysis of multiple quantum-well, slow-light devices under applied external fields using a fully analytical model in fractional dimension

    Energy Technology Data Exchange (ETDEWEB)

    Kohandani, R; Kaatuzian, H [Photonics Research Laboratory, Electrical Engineering Department, AmirKabir University of Technology, Hafez Ave., Tehran (Iran, Islamic Republic of)

    2015-01-31

    We report a theoretical study of optical properties of AlGaAs/GaAs multiple quantum-well (MQW), slow-light devices based on excitonic population oscillations under applied external magnetic and electric fields using an analytical model for complex dielectric constant of Wannier excitons in fractional dimension. The results are shown for quantum wells (QWs) of different width. The significant characteristics of the exciton in QWs such as exciton energy and exciton oscillator strength (EOS) can be varied by application of external magnetic and electric fields. It is found that a higher bandwidth and an appropriate slow-down factor (SDF) can be achieved by changing the QW width during the fabrication process and by applying magnetic and electric fields during device functioning, respectively. It is shown that a SDF of 10{sup 5} is obtained at best. (slowing of light)

  14. The Effect of Rotating a Faraday Disc Perpendicular to an Applied Magnetic Field Theory and Experiment

    Science.gov (United States)

    Mazuruk, Konstantin; Grugel, Richard N.

    2003-01-01

    A magnetohydrodynamic model that examines the effect of rotating an electrically conducting cylinder with a uniform external magnetic field applied orthogonal to its axis is presented. Noting a simple geometry, it can be classified as a fundamental dynamo problem. For the case of an infinitely long cylinder, an analytical solution is obtained and analyzed in detail. A semi-analytical model was developed that considers a finite cylinder. Experimental data from a spinning brass wheel in the presence of Earth's magnetic field were compared to the proposed theory and found to fit well.

  15. Influence of External Static Magnetic Fields on Properties of Metallic Functional Materials

    Directory of Open Access Journals (Sweden)

    Xiaowei Zuo

    2017-12-01

    Full Text Available Influence of external static magnetic fields on solidification, solid phase transformation of metallic materials have been reviewed in terms of Lorentz force, convection, magnetization, orientation, diffusion, and so on. However, the influence of external static magnetic fields on properties of metallic functional materials is rarely reviewed. In this paper, the effect of static magnetic fields subjected in solidification and/or annealing on the properties of Fe–Ga magnetostrictive material, high strength high conductivity Cu-based material (Cu–Fe and Cu–Ag alloys, and Fe–Sn magnetic material were summarized. Both the positive and negative impacts from magnetic fields were found. Exploring to maximize the positive influence of magnetic fields is still a very meaningful and scientific issue in future.

  16. The Interaction of Magnetizations with an External Electromagnetic Field and a Time-Dependent Magnetic Aharonov-Bohm Effect

    International Nuclear Information System (INIS)

    Afanas'ev, G.N.; Stepanovskij, Yu.P.

    1994-01-01

    We investigate how the choice of the magnetization distribution inside the sample affects its interaction with the external electromagnetic field. The strong selectivity to the time dependence of the external electromagnetic field arises for the particular magnetizations. This can be used for the storage and ciphering of information. We propose a time-dependent Aharonov-Bohm-like experiment in which the phase of the wave function is changed by the time-dependent vector magnetic potential. The arising time-dependent interference picture may be viewed as a new channel for the information transfer. 15 refs., 4 figs

  17. A Comparison of Methods to Measure the Magnetic Moment of Magnetotactic Bacteria through Analysis of Their Trajectories in External Magnetic Fields

    Science.gov (United States)

    Fradin, Cécile

    2013-01-01

    Magnetotactic bacteria possess organelles called magnetosomes that confer a magnetic moment on the cells, resulting in their partial alignment with external magnetic fields. Here we show that analysis of the trajectories of cells exposed to an external magnetic field can be used to measure the average magnetic dipole moment of a cell population in at least five different ways. We apply this analysis to movies of Magnetospirillum magneticum AMB-1 cells, and compare the values of the magnetic moment obtained in this way to that obtained by direct measurements of magnetosome dimension from electron micrographs. We find that methods relying on the viscous relaxation of the cell orientation give results comparable to that obtained by magnetosome measurements, whereas methods relying on statistical mechanics assumptions give systematically lower values of the magnetic moment. Since the observed distribution of magnetic moments in the population is not sufficient to explain this discrepancy, our results suggest that non-thermal random noise is present in the system, implying that a magnetotactic bacterial population should not be considered as similar to a paramagnetic material. PMID:24349185

  18. A comparison of methods to measure the magnetic moment of magnetotactic bacteria through analysis of their trajectories in external magnetic fields.

    Directory of Open Access Journals (Sweden)

    Rohan Nadkarni

    Full Text Available Magnetotactic bacteria possess organelles called magnetosomes that confer a magnetic moment on the cells, resulting in their partial alignment with external magnetic fields. Here we show that analysis of the trajectories of cells exposed to an external magnetic field can be used to measure the average magnetic dipole moment of a cell population in at least five different ways. We apply this analysis to movies of Magnetospirillum magneticum AMB-1 cells, and compare the values of the magnetic moment obtained in this way to that obtained by direct measurements of magnetosome dimension from electron micrographs. We find that methods relying on the viscous relaxation of the cell orientation give results comparable to that obtained by magnetosome measurements, whereas methods relying on statistical mechanics assumptions give systematically lower values of the magnetic moment. Since the observed distribution of magnetic moments in the population is not sufficient to explain this discrepancy, our results suggest that non-thermal random noise is present in the system, implying that a magnetotactic bacterial population should not be considered as similar to a paramagnetic material.

  19. Low energy constituent quark and pion effective couplings in a weak external magnetic field

    Science.gov (United States)

    Braghin, Fábio L.

    2018-03-01

    An effective model with pions and constituent quarks in the presence of a weak external background electromagnetic field is derived by starting from a dressed one gluon exchange quark-quark interaction. By applying the auxiliary field and background field methods, the structureless pion limit is considered to extract effective pion and constituent quark couplings in the presence of a weak magnetic field. The leading terms of a large quark and gluon masses expansion are obtained by resolving effective coupling constants which turn out to depend on a weak magnetic field. Two pion field definitions are considered for that. Several relations between the effective coupling constants and parameters can be derived exactly or in the limit of very large quark mass at zero and weak constant magnetic field. Among these ratios, the Gell-Mann-Oakes-Renner and the quark level Goldberger-Treiman relations are obtained. In addition to that, in the pion sector, the leading terms of Chiral Perturbation Theory coupled to the electromagnetic field are recovered. Some numerical estimates are provided for the effective coupling constants and parameters.

  20. Periodical plasma structures controlled by external magnetic field

    Science.gov (United States)

    Schweigert, I. V.; Keidar, M.

    2017-06-01

    The characteristics of two-dimensional periodical structures in a magnetized plasma are studied using kinetic simulations. Ridges (i.e. spikes in electron and ion density) are formed and became more pronounced with an increase of magnetic field incidence angle in the plasma volume in the cylindrical chamber. These ridges are shifted relative to each other, which results in the formation of a two-dimensional double-layer structure. Depending on Larmor radius and Debye length up to 19 potential steps appear across the oblique magnetic field. The electrical current gathered into the channels is associated with the electron and ion density ridges.

  1. Charge transport simulations of NaCl in an external magnetic field: the quest for the Hall effect

    Science.gov (United States)

    Mouhat, F.; Bonella, S.; Pierleoni, C.

    2013-12-01

    In this paper, we set the stage for molecular dynamics studies of the transport properties of molten salts in the presence of external electric and magnetic fields by introducing an original propagator to integrate the equations of motion. Using this algorithm, we compute, within linear response theory, transport properties of molten sodium chloride focusing, in particular, on the conductivity tensor at different intensities of the magnetic field. Finally, in view of full non-equilibrium calculations on the system in which an electric field is also applied, an adapted thermalisation mechanism, which extends to these systems Nosé-Hoover thermostatting, is derived.

  2. Effects of an external magnetic field in pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, T. [Universidad Autonoma de la Ciudad de Mexico (UACM), Prolongacion San Isidro 151, Col. San Lorenzo Tezonco, C.P. 09790, Mexico DF (Mexico)], E-mail: tupacgarcia@yahoo.com; Posada, E. de [CINVESTAV-IPN Unidad Merida, Applied Physics Department, A.P. 73, Cordemex, C.P. 97130 Merida, Yuc. (Mexico); Villagran, M. [CCADET, Universidad Nacional Autonoma de Mexico (UNAM), A.P. 70-186, C.P. 04510, Mexico DF (Mexico); Ll, J.L. Sanchez [Laboratorio de Magnetismo, Facultad de Fisica-IMRE, Universidad de La Habana, La Habana 10400 (Cuba); Bartolo-Perez, P.; Pena, J.L. [CINVESTAV-IPN Unidad Merida, Applied Physics Department, A.P. 73, Cordemex, C.P. 97130 Merida, Yuc. (Mexico)

    2008-12-30

    Thin films were grown by pulsed laser deposition, PLD, on Si (1 0 0) substrates by the ablation of a sintered ceramic SrFe{sub 12}O{sub 19} target with and without the presence of a nonhomogeneous magnetic field of {mu}{sub 0}H = 0.4 T perpendicular to substrate plane and parallel to the plasma expansion axis. The field was produced by a rectangular-shaped Nd-Fe-B permanent magnet and the substrate was just placed on the magnet surface (Aurora method). An appreciable increment of optical emission due to the presence of the magnetic field was observed, but no film composition change or thickness increment was obtained. It suggests that the increment of the optical emission is due mainly to the electron confinement rather than confinement of ionic species.

  3. Applying corrections to digitized data while digitizing magnetic chart

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.

    & Geosciences Vol. 16, No. 2, pp. 263-264, 1990 0098-3004 90 $3.00 - 0.00 Printed m Great Britain. All rights reserved Copyright ~ 1990 Pergamon Press pie SHORT NOTE APPLYING CORRECTIONS TO DIGITIZED DATA WHILE DIGITIZING MAGNETIC CHART T. SURESH National... Institute of Oceanography, Dona-Paula, Goa. India (Received 27 January 1988; accepted 11 March 1989: received for publication 5 September 1989) INTRODUCTION A simple algorithm for determining correct values of magnetic data from digitized data...

  4. Magnetic Solid Phase Extraction Applied to Food Analysis

    Directory of Open Access Journals (Sweden)

    Israel S. Ibarra

    2015-01-01

    Full Text Available Magnetic solid phase extraction has been used as pretreatment technique for the analysis of several compounds because of its advantages when it is compared with classic methods. This methodology is based on the use of magnetic solids as adsorbents for preconcentration of different analytes from complex matrices. Magnetic solid phase extraction minimizes the use of additional steps such as precipitation, centrifugation, and filtration which decreases the manipulation of the sample. In this review, we describe the main procedures used for synthesis, characterization, and application of this pretreatment technique which were applied in food analysis.

  5. Neutral fermion possessing by electric and magnetic moments in external electromagnetic field

    International Nuclear Information System (INIS)

    Khalilov, V.R.

    2001-01-01

    It is shown that in 2+1 dimensions the Dirac equations for a neutral fermion, specified by electric and magnetic dipole moments, is reduced in the electromagnetic field to the Dirac equation for the charged fermion in the external field, characterized by some pseudovector potential. The neutral fermion charge is determined by its dipole moments. The exact solution is found for the Dirac equation for the massive neutral fermion with magnetic and electric dipole moments in the external electromagnetic plane-wave field. The problem on the neutral fermion vacuum polarization in presence of external electromagnetic fields is considered [ru

  6. Surface field in an ensemble of superconducting spheres under external magnetic field

    CERN Document Server

    Peñaranda, A; Ramírez-Piscina, L

    1999-01-01

    We perform calculations of the magnetic field on the surface of an ensemble of superconducting spheres when placed into an external magnetic field, which is the configuration employed in superheated superconducting granule detectors. The Laplace equation is numerically solved with appropriate boundary conditions by means of an iterative procedure and a multipole expansion.

  7. Self-assembly of colloidal particles into strings in a homogeneous external electric or magnetic field

    NARCIS (Netherlands)

    Smallenburg, F.; Vutukuri, H.R.; Imhof, A.; van Blaaderen, A.; Dijkstra, M.

    2012-01-01

    Colloidal particles with a dielectric constant (magnetic susceptibility) mismatch with the surrounding solvent acquire a dipole moment in a homogeneous external electric (magnetic) field. The resulting dipolar interactions can lead to aggregation of the particles into string-like clusters. Recently,

  8. The effect of external magnetic fields on the pore structure of polyurethane foams loaded with magnetic microparticles

    International Nuclear Information System (INIS)

    Schümann, M; Seelig, N; Odenbach, S

    2015-01-01

    Elastic matrices loaded with magnetic microparticles are a new kind of magnetic hybrid material gaining a lot of scientific interest during the last few years. The central advantage of those materials is given by the possibility to control the mechanical properties by external stimuli, in this case external magnetic fields. Due to their extraordinary elastic properties, polyurethane foams are a promising matrix material for a new approach to synthesize such magnetic hybrid materials. A key to a deeper understanding of this new material is the investigation on how the inner structure of the hybrid material is controllable by the application of an external magnetic field during the polymerization. This paper presents a convenient method for analysis of structural changes of magnetically influenced particle loaded polyurethane foams. The geometry and size of up to 40 000 individual pores was evaluated by means of x-ray microtomography and digital image processing. A modest impact of the magnetic field on the pore structure was found with the utilized foam material, proving the convenient applicability of this method for future investigation with magnetic hybrid foams. (paper)

  9. The influence of concentration of Nd-Fe-B powder in composite coating of optical fiber to the sensibility to external magnetic field

    Directory of Open Access Journals (Sweden)

    Radojević Vesna J.

    2005-01-01

    Full Text Available Multi-mode optical fiber with magnetic composite coating was investigated as an optical fiber sensor element (OFMSE for magnetic field sensing The composite coating was formed with dispersions of permanent magnet powder of Nd-Fe-B in poly (ethylene-co-vinyl acetate-EVA solutions in toluene. The influence of the applied external magnetic field on the change of intensity of the light signal propagate trough developed optical fibers sensor element was investigated. In this paper the influence of the content of magnetic powder in the composite coating on the optical propagation characteristics of optical fiber were particularly investigated.

  10. Environmental externalities: Applying the concept to Asian coal-based power generation

    International Nuclear Information System (INIS)

    Szpunar, C.B.; Gillette, J.L.

    1993-03-01

    This report examines the concept of environmental externality. It discusses various factors -- the atmospheric transformations, relationship of point-source emissions to ambient air quality, dose-response relationships, applicable cause-and-effect principles, and risk and valuation research -- that are considered by a number of state utilities when they apply the environmental externality concept to energy resource planning. It describes a methodology developed by Argonne National Laboratory for general use in resource planning, in combination with traditional methods that consider the cost of electricity production. Finally, it shows how the methodology can be applied in Indonesia, Thailand, and Taiwan to potential coal-fired power plant projects that will make use of clean coal technologies

  11. Environmental externalities: Applying the concept to Asian coal-based power generation

    Energy Technology Data Exchange (ETDEWEB)

    Szpunar, C.B.; Gillette, J.L.

    1993-03-01

    This report examines the concept of environmental externality. It discusses various factors -- the atmospheric transformations, relationship of point-source emissions to ambient air quality, dose-response relationships, applicable cause-and-effect principles, and risk and valuation research -- that are considered by a number of state utilities when they apply the environmental externality concept to energy resource planning. It describes a methodology developed by Argonne National Laboratory for general use in resource planning, in combination with traditional methods that consider the cost of electricity production. Finally, it shows how the methodology can be applied in Indonesia, Thailand, and Taiwan to potential coal-fired power plant projects that will make use of clean coal technologies.

  12. Spectrometer for external detection of magnetic and related double resonance

    International Nuclear Information System (INIS)

    Sagalyn, P.L.; Alexander, M.N.

    1977-01-01

    The patent relates to an improvement in nuclear magnetic resonance spectrometer apparatus. It consists of a spectrometer which utilizes separate materials containing, respectively, sample and detector spin systems as opposed to one in which the sample and detector spins are contained in the same single material

  13. Time-dependent scattering of incident light of various wavelengths in ferrofluids under external magnetic field

    Science.gov (United States)

    Jin, Jingyu; Song, Dongxing; Geng, Jiafeng; Jing, Dengwei

    2018-02-01

    Ferrofluids can exhibit the anisotropic thermodynamic properties under magnetic fields. The dynamic optical properties of ferrofluids in the presence of magnetic fields are of particular interest due to their potential application as various optical devices. Although time-dependent light scattering by ferrofluids have been extensively studied, the effect of wavelength of incident light have been rarely considered. Here, for the first time, we investigated both the time- and wavelength-dependent light scattering in water based ferrofluids containing Fe3O4 nanoparticles under an external magnetic field. The field-induced response behavior of the prepared ferrofluid samples was determined and verified first by thermal conductivity measurement and numerical simulation. Double-beam UV-Vis spectrophotometer was employed to record the temporal evolution of transmitted intensity of incident light of various wavelengths passing through the ferrofluid sample and propagating parallel to the applied field. As expected, the light intensity decreases to a certain value right after the field is turned on due to the thermal fluctuation induced disorder inside the flexible particle chains. Then the light intensity further decreases with time until the appearance of a minimum at time τ0 followed by an inversed increase before finally reaches equilibrium at a particular time. More importantly, the characteristic inversion time τ0 was found to follow a power law increase with the wavelength of incident light (τ0 ∼ λα, where α = 2.07). A quantitative explanation for the wavelength dependence of characteristic time was proposed based on the finite-difference time-domain (FDTD) method. The simulation results are in good agreement with our experimental observations. The time-dependent light scattering in ferrofluids under different incident wavelengths was rationalized by considering both the coarsening process of the particle chains and the occurrence of resonance within the

  14. 76 FR 55384 - External Peer Review Meeting for the Draft Guidance of Applying Quantitative Data To Develop Data...

    Science.gov (United States)

    2011-09-07

    ... AGENCY External Peer Review Meeting for the Draft Guidance of Applying Quantitative Data To Develop Data... members of the review panel. The external review draft does not represent Agency policy. The public may... finalizing the draft document, EPA intends to consider the comments from the external peer review meeting...

  15. 76 FR 33752 - Notice of Availability of the External Review Draft of the Guidance for Applying Quantitative...

    Science.gov (United States)

    2011-06-09

    ... AGENCY Notice of Availability of the External Review Draft of the Guidance for Applying Quantitative Data... Environmental Protection Agency (EPA) is announcing a 45- day public comment period for the External Review... seeking public comment prior to external peer review. The document will undergo independent peer review...

  16. Magnetic Driving Flowerlike Soft Platform: Biomimetic Fabrication and External Regulation.

    Science.gov (United States)

    Gao, Wei; Wang, Lanlan; Wang, Xingzhe; Liu, Hongzhong

    2016-06-08

    Nature-inspired actuators that can be driven by various stimuli are an emerging application in mobile microrobotics and microfluidics. In this study, a soft and multiple-environment-adaptive robotic platform with ferromagnetic particles impregnated in silicon-based polymer is adopted to fabricate microrobots for minimally invasive locomotion and control interaction with their environment. As an intelligent structure of platform, the change of its bending, deformation, and flapping displacement is rapid, reversible, and continuously controllable with sweeping and multicycle magnetic actuation. The bending angle of the soft platform (0.2 mm in thickness and 8.5 mm in length) can be deflected up to almost 90° within 2.7 s. Experiments demonstrated that the flexible platform of human skin-like material in various shapes, that is, flowerlike shapes, can transport a cargo to targeted area in air and a variety of liquids. It indicates excellent magnetic-actuation ability and good controllability. The results may be helpful in developing a magnetic-driven carrying platform, which can be operated like a human finger to manipulate biological objects such as single cells, microbeads, or embryos. Especially, it is likely to be used in harsh chemical and physical circumstances.

  17. Impact of spin-zero particle-photon interactions on light polarization in external magnetic fields

    International Nuclear Information System (INIS)

    Liao Yi

    2007-01-01

    If the recent PVLAS results on polarization changes of a linearly polarized laser beam passing through a magnetic field are interpreted by an axion-like particle, it is almost certain that it is not a standard QCD axion. Considering this, we study the general effective interactions of photons with spin-zero particles without restricting the latter to be a pseudo-scalar or a scalar, i.e., a parity eigenstate. At the lowest order in effective field theory, there are two dimension-5 interactions, each of which has previously been treated separately for a pseudo-scalar or a scalar particle. By following the evolution in an external magnetic field of the system of spin-zero particles and photons, we compute the changes in light polarization and the transition probability for two experimental set-ups: one-way propagation and round-trip propagation. While the first may be relevant for astrophysical sources of spin-zero particles, the second applies to laboratory optical experiments like PVLAS. In the one-way propagation, interesting phenomena can occur for special configurations of polarization where, for instance, transition occurs but light polarization does not change. For the round-trip propagation, however, the standard results of polarization changes for a pseudoscalar or a scalar are only modified by a factor that depends on the relative strength of the two interactions

  18. External split field generator

    Science.gov (United States)

    Thundat, Thomas George [Knoxville, TN; Van Neste, Charles W [Kingston, TN; Vass, Arpad Alexander [Oak Ridge, TN

    2012-02-21

    A generator includes a coil disposed about a core. A first stationary magnetic field source may be disposed on a first end portion of the core and a second stationary magnetic field source may be disposed on a second end portion of core. The first and second stationary magnetic field sources apply a stationary magnetic field to the coil. An external magnetic field source may be disposed outside the coil to apply a moving magnetic field to the coil. Electrical energy is generated in response to an interaction between the coil, the moving magnetic field, and the stationary magnetic field.

  19. Using external magnet guidance and endoscopically placed magnets to create suture-free gastro-enteral anastomoses.

    Science.gov (United States)

    Myers, Christopher; Yellen, Benjamin; Evans, John; DeMaria, Eric; Pryor, Aurora

    2010-05-01

    To facilitate endolumenal and natural orifice procedures, this study evaluated a novel technique using external and endoscopically placed magnets to create suture-free gastroenteral anastomoses. Seven anesthetized adult swine underwent endoscopic placement of magnets into the small bowel and stomach. Using external magnets, the endoscopically placed internal magnets were brought into opposition under endoscopic view. After 1-2 weeks, the pigs were killed and analyzed. At laparotomy and under sterile conditions, peritoneal cultures were obtained. The anastomoses were evaluated endoscopically and tested using an air insufflation test. Finally, the anastomoses were resected and evaluated microscopically. The average operative time for endoscopic placement of the magnets was 34.3 +/- 14.8 min. Successful placement and creation of anastomoses occurred in six of the pigs. One pig did not form an anastomosis because the magnets were too large to pass through the pylorus at the time of attempted magnet placement. Six swine experienced uncomplicated postoperative courses. One pig's postoperative course involved constipation for several days, requiring additional fluids and fiber supplementation. The findings at endoscopy showed that the magnets were adhered to the anastomosis, which were easily freed, or within the stomach. The air insufflation test results were negative for all the pigs. At laparotomy, there was no evidence of infection, abscess, or leak, but two peritoneal culture results were positive with scant growth of Staphylococcus aureus and coagulase-negative staphylococcus, presumably contaminants. Microscopically, the anastomoses illustrated granulation and fibrous connective tissue without evidence of infection or leak. Endoscopically placed magnets with external magnet guidance is a feasible and novel approach to creating patent gastroenteral anastomoses without abdominal incisions or sutures.

  20. Gauge invariance of a particle in an external magnetic field

    International Nuclear Information System (INIS)

    Ekstein, H.

    1978-12-01

    In the accepted theory of a nonrelativistic particle in an external field, as well as in the Dirac equation, the canonical momentum p plays a strangely elusive role: contrary to the position q, it has no physical interpretation, yet it is a member of the algebra of observables; nor does it have a well-defined meaning as a translation generator. This paper proposes an observation procedure for p which entails a definite choice for the vector potential A: the radiation gauge divergence of A=0. The canonical momentum, so defined operationally, is shown to be the image of the generator of space translations, in the sense of presymmetry, as the position q is the image of the generator of Galilei boosts in nonrelativistic theories

  1. Nuclear magnetic resonance of external protons using continuous dynamical decoupling with shallow NV centers

    Science.gov (United States)

    de Las Casas, Charles; Ohno, Kenichi; Awschalom, David D.

    2015-03-01

    The nitrogen vacancy (NV) center in diamond is a paramagnetic defect with excellent spin properties that can reside within a few nanometers of the diamond surface, enabling atomic-scale magnetic resonance sensing of external nuclear spins. Here we use rotating frame longitudinal spin relaxation (T1ρ) based sensing schemes, known as Continuous Dynamical Decoupling (CDD), to detect external nuclear spins with shallow NV centers (DIAMANT program.

  2. Suppressed magnetism in Ca2RuO4 under applied electric currents

    Science.gov (United States)

    Bertinshaw, Joel; Gurung, Namrata; Krautloher, Maximilian; Jain, Anil; Porras, Juan; Fabelo Rosa, Oscar; Kim, Bj; Keimer, Bernhard

    The 4 d -electron system Ca2RuO4 plays host to an exciting interplay between spin-orbit coupling and electronic correlation energies that gives rise to exotic ground states and a high sensitivity to external perturbation. Isovalent Sr-doping, hydrostatic pressure and even applied electric currents can induce dramatic changes in the exhibited electronic and magnetic properties. Here, we use single crystal neutron diffraction with in-situ applied electric currents to show that a previously identified current induced metal-insulator transition is linked to a modified distortion of the RuO6 octahedra and a concomitant suppression of antiferromagnetic order. These results indicate a close correlation among the crystal lattice, electronic, and magnetic structures.

  3. Tunneling effect of the spin-2 Bose condensate driven by external magnetic fields

    International Nuclear Information System (INIS)

    Yu Zhaoxian; Jiao Zhiyong

    2004-01-01

    In this Letter, we have studied tunneling effect of the spin-2 Bose condensate driven by external magnetic field. We find that the population transfers among spin-0 and spin-±1, spin-0 and spin-±2 exhibit the step structure under the external cosinusoidal magnetic field, respectively, but there do not exist step structure among spin-±1 and spin-±2. The tunneling current among spin-±1 and spin-±2 may exhibit periodically oscillation behavior, but among spin-0 and spin-±1, spin-0 and spin-±2, the tunneling currents exhibit irregular oscillation behavior

  4. Tunneling effect of the spin-2 Bose condensate driven by external magnetic fields

    OpenAIRE

    Yu, Zhao-xian; Jiao, Zhi-yong

    2003-01-01

    In this paper, we have studied tunneling effect of the spin-2 Bose condensate driven by external magnetic field. We find that the population transfers among spin-0 and spin-$\\pm1$, spin-0 and spin-$\\pm2$ exhibit the step structure under the external cosinusoidal magnetic field respectively, but there do not exist step structure among spin-$\\pm1$ and spin-$\\pm2$. The tunneling current among spin-$\\pm1$ and spin-$\\pm2$ may exhibit periodically oscillation behavior, but among spin-0 and spin-$\\p...

  5. Magnetic Phase Transitions of CeSb. II: Effects of Applied Magnetic Fields

    DEFF Research Database (Denmark)

    Meier, G.; Fischer, P.; Hälg, W.

    1978-01-01

    For pt.I see ibid., vol.11, p.345 (1978). The metamagnetic phase transition and the associated phase diagram of the anomalous antiferromagnet CeSb were determined in a neutron diffraction study of the magnetic ordering of CeSb single crystals in applied magnetic fields parallel to the (001...... magnetic fields. The observed magnetic structures do not correspond to the stable configurations expected from the molecular field theory of the face-centred cubic lattice. The change from a first-order transition at the Neel temperature in zero field to second-order transition at high fields points...

  6. A pulsed magnetic stress applied to Drosophila melanogaster flies

    International Nuclear Information System (INIS)

    Delle Side, D; Giuffreda, E; Nassisi, V; Velardi, L; Bozzetti, M P; Friscini, A; Specchia, V

    2014-01-01

    We report the development of a system to feed pulsed magnetic stress to biological samples. The device is based on a RLC circuit that transforms the energy stored in a high voltage capacitor into a magnetic field inside a coil. The field has been characterized and we found that charging the capacitor with 24 kV results in a peak field of 0.4 T. In order to test its effect, we applied such a stress to the Drosophila melanogaster model and we examined its bio-effects. We analysed, in the germ cells, the effects on the control of specific DNA repetitive sequences that are activated after different environmental stresses. The deregulation of these sequences causes genomic instability and chromosomes breaks leading to sterility. The magnetic field treatment did not produce effects on repetitive sequences in the germ cells of Drosophila. Hence, this field doesn't produce deleterious effects linked to repetitive sequences derepression.

  7. A pulsed magnetic stress applied to Drosophila melanogaster flies

    Science.gov (United States)

    Delle Side, D.; Bozzetti, M. P.; Friscini, A.; Giuffreda, E.; Nassisi, V.; Specchia, V.; Velardi, L.

    2014-04-01

    We report the development of a system to feed pulsed magnetic stress to biological samples. The device is based on a RLC circuit that transforms the energy stored in a high voltage capacitor into a magnetic field inside a coil. The field has been characterized and we found that charging the capacitor with 24 kV results in a peak field of 0.4 T. In order to test its effect, we applied such a stress to the Drosophila melanogaster model and we examined its bio-effects. We analysed, in the germ cells, the effects on the control of specific DNA repetitive sequences that are activated after different environmental stresses. The deregulation of these sequences causes genomic instability and chromosomes breaks leading to sterility. The magnetic field treatment did not produce effects on repetitive sequences in the germ cells of Drosophila. Hence, this field doesn't produce deleterious effects linked to repetitive sequences derepression.

  8. A shear-mode magnetoelectric heterostructure for harvesting external magnetic field energy

    Science.gov (United States)

    He, Wei; Zhang, Jitao; Lu, Yueran; Yang, Aichao; Qu, Chiwen; Yuan, Shuai

    2017-03-01

    In this paper, a magnetoelectric (ME) energy harvester is presented for scavenging external magnetic field energy. The proposed heterostructure consists of a Terfenol-D plate, a piezoelectric PZT5H plate, a NdFeB magnet, and two concentrators. The external magnetic field is concentrated to the Terfenol-D plate and the PZT5H plate working in shear-mode, which can potentially increase the magnetoelectric response. Experiments have been performed to verify the feasibility of the harvester. Under the magnetic field of 0.6 Oe, the device produces a RMS voltage of 0.53 V at the resonant frequency of 32.6 kHz. The corresponding output power reaches 44.96 μW across a 3.1 kΩ matching resistor.

  9. A theoretical study of the dynamics of paramagnetic superrotors in external magnetic fields

    International Nuclear Information System (INIS)

    Floß, Johannes

    2015-01-01

    We present a detailed theoretical study of oxygen molecules in high rotational states (molecular superrotors) interacting with an external magnetic field. The system shows rich dynamics, ranging from a spin-selective splitting of the angular distribution over molecular alignment to an inversion of the rotational direction. We find that the observed magneto-rotational effects are due to a spin-mediated precession of the orbital angular momentum around the magnetic field. Analytical expressions for the precession frequency in the limits of weak and strong magnetic fields are derived and used to support the proposed mechanism. In addition, we provide the procedure for a numerical treatment of oxygen superrotors in an external magnetic field. (paper)

  10. Self propagating high temperature synthesis of metal oxides. Reactions in external magnetic fields

    CERN Document Server

    Aguas, M D

    2001-01-01

    The preparation of metal oxides by Self-Propagating High-Temperature Synthesis is reported. The reactions are started with a point source of ignition; typically a hot wire. A synthesis wave is observed moving out from the point source and reactions terminate in seconds. Products obtained can be classified into ferrites (magnetic applications) and stannates (gas sensing applications). Ferrites were synthesised under variable external magnetic fields. The synthesis wave is hotter in the presence of an external magnetic field for hard ferrite synthesis. For spinel ferrites the opposite was observed. Materials synthesised in the field show differences in their bulk magnetic properties (coercivity and saturation magnetisation), structures and microstructures. Combustion reactions in large fields revealed changes in unit cell volume (shrinkage was observed for hard ferrites while expansion was observed for spinel ferrites). SHS synthesised hard ferrites show two distinct components; one has large grain structure co...

  11. Magnetic neutron scattering resonance of high-¤Tc¤ superconductors in external magnetic fields: An SO(5) study

    DEFF Research Database (Denmark)

    Mortensen, Asger; Rønnow, Henrik Moodysson; Bruus, Henrik

    2000-01-01

    The magnetic resonance at 41 meV observed in neutron scattering studies of YBa2Cu3O7 holds a key position in the understanding of high-T-c, superconductivity. Within the SO(5) model for superconductivity and antiferromagnetism, we have calculated the effect of an applied magnetic field on the neu......The magnetic resonance at 41 meV observed in neutron scattering studies of YBa2Cu3O7 holds a key position in the understanding of high-T-c, superconductivity. Within the SO(5) model for superconductivity and antiferromagnetism, we have calculated the effect of an applied magnetic field...

  12. Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging.

    Science.gov (United States)

    Sangeux, M; Marin, F; Charleux, F; Dürselen, L; Ho Ba Tho, M C

    2006-11-01

    Most in vivo knee kinematic analyses are based on external markers attached to the shank and the thigh. Literature data show that markers positioning and soft tissues artifacts affect the kinematic parameters of the bones true movement. Most of the techniques of quantification used were invasive. The aim of the present study was to develop and apply a non-invasive methodology to compute the relative movement between the bones and the markers. Magnetic resonance imaging acquisitions were performed on the right knee of eleven volunteers without knee injury. The subjects were equipped with external magnetic resonance imaging-compatible marker sets. A foot drive device allowed the subjects to perform an actively loaded knee extension. The whole volume of the subject's knee was processed for four sequentially held knee flexion positions during the knee movement. The bones and external marker sets geometry were reconstructed from magnetic resonance imaging images. Then a registration algorithm was applied to the bones and the relative movement of the thigh and shank marker sets with respect to their underlying bones was computed. The protocol resulted in a good geometrical accuracy and reproducibility. Marker sets movement differ from that of the bones with a maximum of 22 mm in translation and 15 degrees in rotation and it affects the knee kinematics. Marker sets relative movement modify the knee movement finite helical axes direction (range 10-35 degrees ) and localization (range 0-40 mm). The methodology developed can evaluate external marker set system to be used for kinematic analysis in a clinical environment.

  13. Noise-spectroscopy of multiqubit systems: Determining all their parameters by applying an external classical noise

    Energy Technology Data Exchange (ETDEWEB)

    Savel' ev, S., E-mail: S.Saveliev@lboro.ac.uk [Department of Physics, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Zagoskin, A.M. [Department of Physics, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Omelyanchouk, A.N. [Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan); B. Verkin Institute for Low Temperature Physics and Engineering, 61103 Kharkov (Ukraine); Nori, Franco [Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Physics Department, University of Michigan, Ann Arbor, MI 48109-1040 (United States)

    2010-10-05

    Imagine that you have several sets of two coupled qubits, but you do not know the parameters of their Hamitonians. How to determine these without resorting to the usual spectroscopy approach to the problem? Based on numerical modeling, we show that all the parameters of a system of two coupled qubits can be determined by applying to it an external classical noise and analyzing the Fourier spectrum of the elements of the system's density matrix. In particular, the interlevel spacings as well as the strength and sign of the qubit-qubit coupling can be determined this way.

  14. Effects of Exponential Nonlinear Electrodynamics and External Magnetic Field on Holographic Superconductors

    Science.gov (United States)

    Sheykhi, A.; Abdollahzadeh, Z.

    2018-03-01

    We investigate the effects of an external magnetic field as well as exponential nonlinear electrodynamics on the properties of s-wave holographic superconductors. Our strategy for this study is the matching method, which is based on the match of the solutions near the horizon and on the boundary at some intermediate point. When the magnetic field is turned off, we obtain the critical temperature as well as the condensation operator and show that the critical exponent is still 1/2, which is the universal value in the mean field theory. Then, we turn on the magnetic field and obtain the critical magnetic field, B c , in order to study its behavior in terms of the temperature. Interestingly enough, we find that in the presence of exponential nonlinear electrodynamics, the critical temperature decreases, while the critical magnetic field increases compared to the Maxwell case. We also observe that the critical magnetic field increases with increasing the nonlinear parameter b.

  15. Exotic Applied Magnetics: Biomagnetism; Kyomiaru jiki oyo: seitai denjikigaku

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Masatami [Kagawa University, Kagawa (Japan). Faculty of Engineering

    1999-09-25

    This paper discusses biomagnetic effects and their possible applications that are unfamiliar to cryogenic and superconducting engineers. Biomagnetism is exotic applied magnetics and a trans-disciplinary research target. There are two types of research methodology, physical and epidemiological. They are quite different. Both methodologies should be harmonized. The author proposes how to work in this transdisciplinary field. Finally, suggestions of guidelines for studing exotic phenomena are presented. (author)

  16. [Synergetic killing effects of external magnetic fields combined with porphyrin-dextran magnetic nanoparticles on the human bladder cancer cells].

    Science.gov (United States)

    Luo, Dao-sheng; Mi, Qi-wu; Meng, Xiang-jun; Gao, Yong; Dai, Yu-ping; Deng, Chun-hua

    2012-08-18

    To study the synergetic killing effects of external magnetic fields combined with the photodynamic action of porphyrin-dextran iron oxide magnetic nanoparticles (PDMN) on human bladder cancer cells in vitro. The PDMN were produced by using the chemical co-precipitation and redox process and the physicochemical properties were characterized. Methyl thiazolyl tetrazolium (MTT) and flow cytometry were used to determine the effects of photodynamic therapy of PDMN combined with external pulsed electromagnetic fields (5 mT) on killing human bladder cancer BIU-87 cells respectively. The diameters of PDMN were 10-15 nm and the saturation magnetization was 0.20 emu/g. Effective diameter of PDMN was 94.8 nm. PDMN could remarkably inhibit the proliferation and induce the obvious apoptosis of BIU-87 cells, and the rates of growth inhibition and apoptosis were (17.61±2.73)% and (24.53±5.74)% respectively. Moreover, external pulsed electromagnetic fields (5 mT) could also suppress the proliferation and induce apoptosis of BIU-87 cells. Furthermore, the photodynamic action of PDMN combined with external magnetic fields significantly inhibited the proliferation and promote apoptosis of BIU-87 cells, and the rates of growth inhibition and apoptosis was (28.11±4.25)% and (24.53±5.74)%, respectively, which were significantly higher than those of other groups (Peffectively inhibit proliferation and induce apoptosis of BIU-87 cells. Moreover, these effects on BIU-87 cells could be strengthened by the combination with external magnetic fields.

  17. Influences of externally applied potential on the properties of microscopic particles in nonlinear quantum systems

    International Nuclear Information System (INIS)

    Pang Xiaofeng

    2010-01-01

    When the Schroedinger equation in quantum mechanics is replaced by the nonlinear Schroedinger equation to describe microscopic particles in nonlinear quantum systems, it has been verified that the nature of the particles differs considerably from those in quantum mechanics, where they are localized and have also wave-corpuscle duality due to the nonlinear interactions. In this case the influences of externally applied potentials in the nonlinear Schroedinger equation on the natures of the microscopic particles have been studied by a perturbation theory. The studied results show that the external potential can change the states of the microscopic particles, such as the positions, amplitude and wave forms, but cannot change the wave-corpuscle duality. In the meanwhile, we find further that the relationship between the external potential and change of positions of the particle satisfies the rule of motion of classical particles. Thus we know from this study that the kinetic energy term, (h 2 /2m)∇ 2 φ, in the nonlinear Schroedinger equation can only make the microscopic particles have a wave feature, but the nonlinear interaction b|φ| 2 φ determines its corpuscle feature, their combination makes the microscopic particles have a wave-corpuscle duality, and the potential V(r → ,t)φ changes only the positions, amplitude and wave form of the particles. Therefore the nonlinear interaction plays an important role in determination of the wave-corpuscle duality of microscopic particles in quantum theory.

  18. Experimental investigation on heat transfer rate of Co–Mn ferrofluids in external magnetic field

    Directory of Open Access Journals (Sweden)

    Margabandhu M.

    2016-06-01

    Full Text Available Manganese substituted cobalt ferrite (Co1–xMnxFe2O4 with x = 0, 0.3, 0.5, 0.7 and 1 nanopowders were synthesized by chemical coprecipitation method. The synthesized magnetic nanoparticles were investigated by various characterization techniques, such as X-ray diffraction (XRD, vibrating sample magnetometry (VSM, scanning electron microscopy (SEM and thermogravimetric and differential thermal analysis (TG/DTA. The XRD results confirmed the presence of cubic spinel structure of the prepared powders and the average crystallite size of magnetic particles ranging from 23 to 45 nm. The VSM results showed that the magnetic properties varied with an increase in substituted manganese while SEM analysis showed the change in the morphology of obtained magnetic nanoparticles. The TG/DTA analysis indicated the formation of crystalline structure of the synthesized samples. The heat transfer rate was measured in specially prepared magnetic nanofluids (nanoparticles dispersed in carrier fluid transformer oil as a function of time and temperature in presence of external magnetic fields. The experimental analysis indicated enhanced heat transfer rate of the magnetic nanofluids which depended upon the strength of external magnetic field and chemical composition.

  19. Parametric instabilities in shallow water magnetohydrodynamics of astrophysical plasma in external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Klimachkov, D.A., E-mail: klimachkovdmitry@gmail.com [Space Research Institute of Russian Academy of Science, 84/32, Profsoyuznaya str., Moscow, 117997 (Russian Federation); Petrosyan, A.S. [Space Research Institute of Russian Academy of Science, 84/32, Profsoyuznaya str., Moscow, 117997 (Russian Federation); Moscow Institute of Physics and Technology (State University), 9 Institutskyi per., Dolgoprudny, Moscow Region, 141700 (Russian Federation)

    2017-01-15

    This article deals with magnetohydrodynamic (MHD) flows of a thin rotating layer of astrophysical plasma in external magnetic field. We use the shallow water approximation to describe thin rotating plasma layer with a free surface in a vertical external magnetic field. The MHD shallow water equations with external vertical magnetic field are revised by supplementing them with the equations that are consequences of the magnetic field divergence-free conditions and reveal the existence of third component of the magnetic field in such approximation providing its relation with the horizontal magnetic field. It is shown that the presence of a vertical magnetic field significantly changes the dynamics of the wave processes in astrophysical plasma compared to the neutral fluid and plasma layer in a toroidal magnetic field. The equations for the nonlinear wave packets interactions are derived using the asymptotic multiscale method. The equations for three magneto-Poincare waves interactions, for three magnetostrophic waves interactions, for the interactions of two magneto-Poincare waves and for one magnetostrophic wave and two magnetostrophic wave and one magneto-Poincare wave interactions are obtained. The existence of parametric decay and parametric amplifications is predicted. We found following four types of parametric decay instabilities: magneto-Poincare wave decays into two magneto-Poincare waves, magnetostrophic wave decays into two magnetostrophic waves, magneto-Poincare wave decays into one magneto-Poincare wave and one magnetostrophic wave, magnetostrophic wave decays into one magnetostrophic wave and one magneto-Poincare wave. Following mechanisms of parametric amplifications are found: parametric amplification of magneto-Poincare waves, parametric amplification of magnetostrophic waves, magneto-Poincare wave amplification in magnetostrophic wave presence and magnetostrophic wave amplification in magneto-Poincare wave presence. The instabilities growth rates

  20. Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging

    Science.gov (United States)

    Huettner, Andrew M.; Mickevicius, Nikolai J.; Ersoz, Ali; Koch, Kevin M.; Muftuler, L. Tugan; Nencka, Andrew S.

    2015-01-01

    A new method for designing radiofrequency (RF) pulses with numerical optimization in the wavelet domain is presented. Numerical optimization may yield solutions that might otherwise have not been discovered with analytic techniques alone. Further, processing in the wavelet domain reduces the number of unknowns through compression properties inherent in wavelet transforms, providing a more tractable optimization problem. This algorithm is demonstrated with simultaneous multi-slice (SMS) spin echo refocusing pulses because reduced peak RF power is necessary for SMS diffusion imaging with high acceleration factors. An iterative, nonlinear, constrained numerical minimization algorithm was developed to generate an optimized RF pulse waveform. Wavelet domain coefficients were modulated while iteratively running a Bloch equation simulator to generate the intermediate slice profile of the net magnetization. The algorithm minimizes the L2-norm of the slice profile with additional terms to penalize rejection band ripple and maximize the net transverse magnetization across each slice. Simulations and human brain imaging were used to demonstrate a new RF pulse design that yields an optimized slice profile and reduced peak energy deposition when applied to a multiband single-shot echo planar diffusion acquisition. This method may be used to optimize factors such as magnitude and phase spectral profiles and peak RF pulse power for multiband simultaneous multi-slice (SMS) acquisitions. Wavelet-based RF pulse optimization provides a useful design method to achieve a pulse waveform with beneficial amplitude reduction while preserving appropriate magnetization response for magnetic resonance imaging. PMID:26517262

  1. Pose control of the chain composed of magnetic particles using external uniform and gradient magnetic fields

    International Nuclear Information System (INIS)

    Zhou, J. F.; Shao, C. L.; Gu, B. Q.

    2016-01-01

    Magnetic particles (MPs) are known to respond to a magnetic field and can be moved by magnetic force, which make them good carriers in bioengineering and pharmaceutical engineering. In this paper, a pose control method for the straight chain composed of MPs is proposed, and the chain with one pose can be moved to another position with another pose using alternately employed uniform and gradient magnetic fields. Based on computer simulations, it is revealed that in the uniform magnetic field, the MPs form a straight chain with the same separation space along the field lines, and once the uniform magnetic field rotates, the chain also rotates with the field. In the gradient magnetic field, the MPs move toward the higher field so that the translation of the chain can be realized. The simulation results indicate that while the uniform magnetic field is rotating, there exists certain hysteresis between the chain and the field, and the chain is not straight anymore. So the uniform magnetic field should rest at the target angle for a period to make the chain fully relax to be straight. For nanoMP, its magnetic moment directly determines the gradient magnetic force which is much smaller than the dipole–dipole force among MPs. Therefore, the translation of the chain is much more time-consuming than rotation. To enlarge the translational velocity, it is suggested to increase the size of MPs or the magnetic field gradient

  2. Neutral meson properties under an external magnetic field in nonlocal chiral quark models

    Science.gov (United States)

    Gómez Dumm, D.; Izzo Villafañe, M. F.; Scoccola, N. N.

    2018-02-01

    We study the behavior of neutral meson properties in the presence of a static uniform external magnetic field in the context of nonlocal chiral quark models. The formalism is worked out introducing Ritus transforms of Dirac fields, which allow to obtain closed analytical expressions for π0 and σ meson masses and for the π0 decay constant. Numerical results for these observables are quoted for various parametrizations. In particular, the behavior of the π0 meson mass with the magnetic field is found to be in good agreement with lattice QCD results. It is also seen that the Goldberger-Treiman and Gell-Mann-Oakes-Renner chiral relations remain valid within these models in the presence of the external magnetic field.

  3. Spin polarization in high density quark matter under a strong external magnetic field

    DEFF Research Database (Denmark)

    Tsue, Yasuhiko; Da Providência, João; Providência, Constança

    2016-01-01

    In high density quark matter under a strong external magnetic field, possible phases are investigated by using the two-flavor Nambu-Jona-Lasinio (NJL) model with tensor-type four-point interaction between quarks, as well as the axial-vector-type four-point interaction. In the tensor-type interact......In high density quark matter under a strong external magnetic field, possible phases are investigated by using the two-flavor Nambu-Jona-Lasinio (NJL) model with tensor-type four-point interaction between quarks, as well as the axial-vector-type four-point interaction. In the tensor...... phase appears in the wide range of the quark chemical potential. In both the interactions, the quark mass in zero and small chemical potential regions increases which indicates that the chiral symmetry breaking is enhanced, namely the magnetic catalysis occurs....

  4. Chaotic oscillations in electron beam with virtual cathode in external magnetic field

    Science.gov (United States)

    Hramov, A. E.; Koronovskiy, A. A.; Kurkin, S. A.; Rempen, I. S.

    2011-11-01

    This article presents the results of a numerical study of external magnetic field influence on the conditions and mechanisms of virtual cathode (VC) formation in a relativistic electron beam. It also considers other related issues, e.g. peculiarities of nonlinear dynamics of electron beam with VC under changed external magnetic field, different mechanisms of VC oscillation chaotisation leading to complication of vircator system dynamics and appearance of multi-frequency VC oscillations. General systemic mechanism of VC oscillation chaotisation has been identified which is connected with formation of electronic patterns in electron beam whose interaction in the common field of spatial charge determines appearance of additional inner feedback. Transition from chaotic to periodical oscillation regime is found to be connected with destroying the mechanism of secondary electronic structures (electron bunches) formation. Besides, the influence of extent of screening of electron gun from magnetic field is discussed.

  5. Laser ablation with applied magnetic field for electric propulsion

    Science.gov (United States)

    Batishcheva, Alla; Batishchev, Oleg; Cambier, Jean-Luc

    2012-10-01

    Using ultrafast lasers with tera-watt-level power allows efficient ablation and ionization of solid-density materials [1], creating dense and hot (˜100eV) plasma. We propose ablating small droplets in the magnetic nozzle configurations similar to mini-helicon plasma source [2]. Such approach may improve the momentum coupling compared to ablation of solid surfaces and facilitate plasma detachment. Results of 2D modeling of solid wire ablation in the applied magnetic field are presented and discussed. [4pt] [1] O. Batishchev et al, Ultrafast Laser Ablation for Space Propulsion, AIAA technical paper 2008-5294, -16p, 44th JPC, Hartford, 2008.[0pt] [2] O. Batishchev and J.L. Cambier, Experimental Study of the Mini-Helicon Thruster, Air Force Research Laboratory Report, AFRL-RZ-ED-TR-2009-0020, 2009.

  6. Magnetic isotope and external magnetic field effects upon the photo-Fries rearrangement of 1-naphthyl acetate

    International Nuclear Information System (INIS)

    Nakagaki, R.; Hiramatsu, M.; Watanabe, T.; Tanimoto, Y.; Nagakura, S.

    1985-01-01

    The reaction mechanisms of the photo-Fries rearrangement of 1-naphthyl acetate has been studied by means of steady-state photolysis and laser flash photolysis. A radical pair consisting of the 1-naphthoxyl and acetyl radicals is concluded to be a reaction intermediate. The yield of an in-cage product (2-acetyl-1-naphthol) exhibits a positive external magnetic field effect for the ester labeled by magnetically active 13 C, but no effect for the normal 12 C ester. The magnetic field effect observed for the labeled ester is quantitatively or semiquantitatively explained in terms of the radical-pair mechanism by considering hyperfine coupling between magnetically active nuclei ( 1 H and 13 C) and an unpaired electron in the acetyl radical. The in-cage product is formed through the singlet radical pair. 26 references, 5 figures, 3 tables

  7. Calibration of an inertial-magnetic measurement unit without external equipment, in the presence of dynamic magnetic disturbances

    International Nuclear Information System (INIS)

    Metge, J; Giremus, A; Mégret, R; Berthoumieu, Y; Décamps, T

    2014-01-01

    Inertial-magnetic measurement units are inexpensive sensors, widely used in electronic systems (smartphones, GPS, micro-UAV, etc). However the precision of these sensors is highly dependent on their calibration. This article proposes a complete solution to calibrate the sensors (accelerometers, gyrometers and magnetometers), the inter-sensor rotations and the dynamic disturbances of the magnetic field due to the immediate environment. Contrary to most of the existing techniques, the proposed method does not necessitate any external equipment, apart from the sensors already included in the system. The calibration can be performed by hand manipulation by the final user. Simulations and experiments show the advantages of the proposed approach. (paper)

  8. Positioning and aligning CNTs by external magnetic field to assist localised epoxy cure

    Science.gov (United States)

    Ariu, G.; Hamerton, I.; Ivanov, D.

    2016-01-01

    This work focuses on the generation of conductive networks through the localised alignment of nano fillers, such as multi-walled carbon nanotubes (MWCNTs). The feasibility of alignment and positioning of functionalised MWCNTs by external DC magnetic fields was investigated. The aim of this manipulation is to enhance resin curing through AC induction heating due to hysteresis losses from the nanotubes. Experimental analyses focused on in-depth assessment of the nanotube functionalisation, processing and characterisation of magnetic, rheological and cure kinetics properties of the MWCNT solution. The study has shown that an external magnetic field has great potential for positioning and alignment of CNTs. The study demonstrated potential for creating well-ordered architectures with an unprecedented level of control of network geometry. Magnetic characterisation indicated cobalt-plated nanotubes to be the most suitable candidate for magnetic alignment due to their high magnetic sensitivity. Epoxy/metal-plated CNT nanocomposite systems were validated by thermal analysis as induction heating mediums. The curing process could therefore be optimised by the use of dielectric resins. This study offers a first step towards the proof of concept of this technique as a novel repair technology.

  9. Positioning and aligning CNTs by external magnetic field to assist localised epoxy cure

    Directory of Open Access Journals (Sweden)

    Ariu G.

    2016-01-01

    Full Text Available This work focuses on the generation of conductive networks through the localised alignment of nano fillers, such as multi-walled carbon nanotubes (MWCNTs. The feasibility of alignment and positioning of functionalised MWCNTs by external DC magnetic fields was investigated. The aim of this manipulation is to enhance resin curing through AC induction heating due to hysteresis losses from the nanotubes. Experimental analyses focused on in-depth assessment of the nanotube functionalisation, processing and characterisation of magnetic, rheological and cure kinetics properties of the MWCNT solution. The study has shown that an external magnetic field has great potential for positioning and alignment of CNTs. The study demonstrated potential for creating well-ordered architectures with an unprecedented level of control of network geometry. Magnetic characterisation indicated cobalt-plated nanotubes to be the most suitable candidate for magnetic alignment due to their high magnetic sensitivity. Epoxy/metal-plated CNT nanocomposite systems were validated by thermal analysis as induction heating mediums. The curing process could therefore be optimised by the use of dielectric resins. This study offers a first step towards the proof of concept of this technique as a novel repair technology.

  10. Torque Ripple Suppression in an External-Meshed Magnetic Gear Train

    Directory of Open Access Journals (Sweden)

    Yi-Chang Wu

    2013-01-01

    Full Text Available Magnetic gear trains transmit torque through noncontact magnetic couplings rather than conjugate gear teeth; they have the unique advantages of reduced maintenance and improved reliability, inherent overload protection, high efficiency, precise peak torque transmission, and tolerance for misalignment. Smooth and steadily transmitted torque is an important characteristic for a magnetic gear train. It is necessary for the reduction of possible mechanical vibration, position inaccuracy, and acoustic noise. This paper investigates the transmitted torque characteristics, especially torque ripple reduction, of an external-meshed magnetic gear train using finite-element analysis (FEA. The topological structure and working principles of a simple magnetic gear train with parallel axes are introduced. With the aid of a commercial FEA package, the transmitted torque waveform of a magnetic gear train is numerically calculated. The effects of geometrical parameters on the maximum transmitted torque and torque ripple are further discussed in terms of obtaining a magnetic gear train with high transmitted torque or low torque ripple. This examination offers insights beneficial to future magnetic gear mechanism design.

  11. Effect of an External Oriented Magnetic Field on Entropy Generation in Natural Convection

    Directory of Open Access Journals (Sweden)

    Atef El Jery

    2010-05-01

    Full Text Available The influence of an external oriented magnetic field on entropy generation in natural convection for air and liquid gallium is numerically studied in steady-unsteady states by solving the mass, the momentum and the energy conservation equations. Entropy generation depends on five parameters which are: the Prandtl number, the irreversibility coefficients, the inclination angle of the magnetic field, the thermal Grashof and the Hartmann numbers. Effects of these parameters on total and local irreversibilities as well as on heat transfer and fluid flow are studied. It was found that the magnetic field tends to decrease the convection currents, the heat transfer and entropy generation inside the enclosure. Influence of inclination angle of the magnetic field on local irreversibility is then studied.

  12. Dipolar structures in magnetite ferrofluids studied with small-angle neutron scattering with and without applied magnetic field.

    Science.gov (United States)

    Klokkenburg, M; Erné, B H; Wiedenmann, A; Petukhov, A V; Philipse, A P

    2007-05-01

    Field-induced structure formation in a ferrofluid with well-defined magnetite nanoparticles with a permanent magnetic dipole moment was studied with small-angle neutron scattering (SANS) as a function of the magnetic interactions. The interactions were tuned by adjusting the size of the well-defined, single-magnetic-domain magnetite (Fe3O4) particles and by applying an external magnetic field. For decreasing particle dipole moments, the data show a progressive distortion of the hexagonal symmetry, resulting from the formation of magnetic sheets. The SANS data show qualitative agreement with recent cryogenic transmission electron microscopy results obtained in 2D [Klokkenburg, Phys. Rev. Lett. 97, 185702 (2006)] on the same ferrofluids.

  13. Dependence of electrical property on the applied magnetic fields in spin coated Fe(III)-Phorphyrin films

    International Nuclear Information System (INIS)

    Utari; Kusumandari; Purnama, B.; Mudasir; Abraha, K.

    2016-01-01

    We report here on the experimental results of the effect of external magnetic field on the current flow in plane surface of Fe(III)-porphyrin thin layer. The deposition of the Fe(III)- porphyrin thin layer was done by spin coating method. The I-V characteristics of film were measured by means of two point probes. The sample of layer number N = 4 was used to evaluate the magnetic effect on the electrical currents. The ohmic characteristics of the I-V film measurement were obtained. The current decreases when magnetic field is applied to the system and saturated current is obtained at a given magnetic field. Here, the decrease in the current can be attributed to the recombination of carrier charge under the magnetic field. In addition, the magnitude of the saturated current is found to increase with the increase in the voltage used. (paper)

  14. A sphericon-shaped magnetic millirobot rolling on a surface actuated by an external wobbling magnetic field

    Directory of Open Access Journals (Sweden)

    Seungmun Jeon

    2017-05-01

    Full Text Available This paper proposes a novel sphericon-shaped magnetic millirobot (SSMM that can roll on a variety of surfaces. The SSMM comprises four identical half cones with a cylindrical magnet inserted into the geometric center. It can roll forward or backward on a surface with repeated rolling cone motions (wobbling motions. Since a rolling SSMM develops its entire surface by means of line contact, a relatively large maximum static friction force can make the SSMM move on a surface steadily and effectively. In this work, a new type of external wobbling magnetic field (EWMF was also derived to manipulate the SSMM’s rolling motions precisely. Then, the controlled rolling motions of prototype SSMMs under various surface conditions were demonstrated to examine the rolling ability of the proposed SSMM.

  15. Design Enhancement and Performance Examination of External Rotor Switched Flux Permanent Magnet Machine for Downhole Application

    Science.gov (United States)

    Kumar, R.; Sulaiman, E.; Soomro, H. A.; Jusoh, L. I.; Bahrim, F. S.; Omar, M. F.

    2017-08-01

    The recent change in innovation and employments of high-temperature magnets, permanent magnet flux switching machine (PMFSM) has turned out to be one of the suitable contenders for seaward boring, however, less intended for downhole because of high atmospheric temperature. Subsequently, this extensive review manages the design enhancement and performance examination of external rotor PMFSM for the downhole application. Preparatory, the essential design parameters required for machine configuration are computed numerically. At that point, the design enhancement strategy is actualized through deterministic technique. At last, preliminary and refined execution of the machine is contrasted and as a consequence, the yield torque is raised from 16.39Nm to 33.57Nm while depreciating the cogging torque and PM weight up to 1.77Nm and 0.79kg, individually. In this manner, it is inferred that purposed enhanced design of 12slot-22pole with external rotor is convenient for the downhole application.

  16. Influence of AC external magnetic field on guidance force relaxation between HTS bulk and NdFeB guideway

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Longcai [Applied Superconductivity Laboratory, P.O. Box 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)], E-mail: zhlcai2000@163.com; Wang Suyu; Wang Jiasu; Zheng Jun [Applied Superconductivity Laboratory, P.O. Box 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)

    2007-12-01

    Superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the HTS bulks are always exposed to time-varying external magnetic field, which is generated by the inhomogeneous surface magnetic field of the NdFeB guideway. So it is required to study whether the guidance force of the bulks is influenced by the inhomogeneity. In this paper, we studied the characteristics of the guidance force relaxation between the HTS bulk and the NdFeB guideway by an experiment in which AC external magnetic field generated by an electromagnet was used to simulate the time-varying external magnetic field caused by the inhomogeneity of the guideway. From the experiment results, it was found that the guidance force was decreased with the application of the AC external magnetic field, and the decay increased with the amplitude and was almost independent of the frequency.

  17. Neurite outgrowth on chromaffin cells applying extremely low frequency magnetic fields by permanent magnets.

    Science.gov (United States)

    Hernández-Hernández, Hugo; Cruces-Solis, Hugo; Elías-Viñas, David; Verdugo-Díaz, Leticia

    2009-10-01

    There is an increasing interest about the effects of electromagnetic fields on health and clinical applications. Electromagnetic fields have been shown to promote differentiation and regeneration of many tissues. The purpose of the present study was to evaluate if a magnetic field (MF) varying in time is able to induce neurite outgrowth in cultured chromaffin cells. For this reason, a stimulation system was developed in order to generate a magnetic field, using permanent magnets as a supply. In this investigation we used a pair of permanent ferrite magnets. These were mounted in a mechanical system in which both magnets rotate around a culture Petri dish. The stimulation device was designed at Centro de Investigación y de Estudios Avanzados, Avanzados del IPN, Mexico City. Primary cultures of chromaffin cells were stimulated with a magnetic field of 6.4 mT and 4, 7, 10 or 12Hz (2h daily, during a 7-day period). After treatment, percentage of neurite outgrowth was calculated. Our results show that the magnetic fields produced by rotating permanent magnets induced neurite outgrowth on chromaffin cells at 7 and 10Hz. The present study provides evidence that MFs varying in time (7 and 10Hz) induce neurite outgrowth in chromaffin cells. These studies will contribute to elucidate the effect of noninvasive MF stimulus in order to apply it in future regeneration therapies. Also, the device designed could be used for different kind of cells and may work as a model for future clinical devices. 2009 IMSS. Published by Elsevier Inc.

  18. Relationship between external anal sphincter atrophy at endoanal magnetic resonance imaging and clinical, functional, and anatomic characteristics in patients with fecal incontinence

    NARCIS (Netherlands)

    Terra, Maaike P.; Deutekom, Marije; Beets-Tan, Regina G. H.; Engel, Alexander F.; Janssen, Lucas W. M.; Boeckxstaens, Guy E. E.; Dobben, Annette C.; Baeten, Cor G. M. I.; de Priester, Jacobus A.; Bossuyt, Patrick M. M.; Stoker, Jaap

    2006-01-01

    PURPOSE: External anal sphincter atrophy at endoanal magnetic resonance imaging has been associated with poor outcome of anal sphincter repair. We studied the relationship between external anal sphincter atrophy on endoanal magnetic resonance imaging and clinical, functional, and anatomic

  19. An Empirical Orthogonal Function Reanalysis of the Northern Polar External and Induced Magnetic Field During Solar Cycle 23

    Science.gov (United States)

    Shore, R. M.; Freeman, M. P.; Gjerloev, J. W.

    2018-01-01

    We apply the method of data-interpolating empirical orthogonal functions (EOFs) to ground-based magnetic vector data from the SuperMAG archive to produce a series of month length reanalyses of the surface external and induced magnetic field (SEIMF) in 110,000 km2 equal-area bins over the entire northern polar region at 5 min cadence over solar cycle 23, from 1997.0 to 2009.0. Each EOF reanalysis also decomposes the measured SEIMF variation into a hierarchy of spatiotemporal patterns which are ordered by their contribution to the monthly magnetic field variance. We find that the leading EOF patterns can each be (subjectively) interpreted as well-known SEIMF systems or their equivalent current systems. The relationship of the equivalent currents to the true current flow is not investigated. We track the leading SEIMF or equivalent current systems of similar type by intermonthly spatial correlation and apply graph theory to (objectively) group their appearance and relative importance throughout a solar cycle, revealing seasonal and solar cycle variation. In this way, we identify the spatiotemporal patterns that maximally contribute to SEIMF variability over a solar cycle. We propose this combination of EOF and graph theory as a powerful method for objectively defining and investigating the structure and variability of the SEIMF or their equivalent ionospheric currents for use in both geomagnetism and space weather applications. It is demonstrated here on solar cycle 23 but is extendable to any epoch with sufficient data coverage.

  20. dc properties of series-parallel arrays of Josephson junctions in an external magnetic field

    International Nuclear Information System (INIS)

    Lewandowski, S.J.

    1991-01-01

    A detailed dc theory of superconducting multijunction interferometers has previously been developed by several authors for the case of parallel junction arrays. The theory is now extended to cover the case of a loop containing several junctions connected in series. The problem is closely associated with high-T c superconductors and their clusters of intrinsic Josephson junctions. These materials exhibit spontaneous interferometric effects, and there is no reason to assume that the intrinsic junctions form only parallel arrays. A simple formalism of phase states is developed in order to express the superconducting phase differences across the junctions forming a series array as functions of the phase difference across the weakest junction of the system, and to relate the differences in critical currents of the junctions to gaps in the allowed ranges of their phase functions. This formalism is used to investigate the energy states of the array, which in the case of different junctions are split and separated by energy barriers of height depending on the phase gaps. Modifications of the washboard model of a single junction are shown. Next a superconducting inductive loop containing a series array of two junctions is considered, and this model is used to demonstrate the transitions between phase states and the associated instabilities. Finally, the critical current of a parallel connection of two series arrays is analyzed and shown to be a multivalued function of the externally applied magnetic flux. The instabilities caused by the presence of intrinsic serial junctions in granular high-T c materials are pointed out as a potential source of additional noise

  1. MHD-equilibrium and stability of a z-pinch in an external magnetic field

    International Nuclear Information System (INIS)

    Brynolf, J.

    1982-05-01

    The freeboundary of a sharp z-pinch plasma surrounded by four external conductors, all carrying the same current, is solved. This problem, which is considered as two-dimensional, is transformed by a conformal mapping of the vacuum domain onto the outside of the unit circle. In this area both the complex potential and the mapping itself are analytical functions with wellknown boundary values and hence they can be solved unicely. For the configuration where the external conductors lie in the corner of a square, an analytical expression for the coordinates of the surface is found. Each ratio between the plasma and the vacuum currents results in a family of surfaces in which each member can be labeled either with the magnetic field strength on the surface or with the distance to the external conductors. In section III, the energy principle is used to investigate the stability of the equilibrium configurations against two-dimensional displacements. They are found both analytically and by computer to be unstable for all parametervalues. Without external currents any translation gives marginal stability. For the case with conductors froming a square an analysis of the stability against ridig-body translation gives the opposite result. Then the external currents instead have a stabilizing effect. (Author)

  2. External Magnetic Field Reduction Techniques for the Advanced Stirling Radioisotope Generator

    Science.gov (United States)

    Niedra, Janis M.; Geng, Steven M.

    2013-01-01

    Linear alternators coupled to high efficiency Stirling engines are strong candidates for thermal-to-electric power conversion in space. However, the magnetic field emissions, both AC and DC, of these permanent magnet excited alternators can interfere with sensitive instrumentation onboard a spacecraft. Effective methods to mitigate the AC and DC electromagnetic interference (EMI) from solenoidal type linear alternators (like that used in the Advanced Stirling Convertor) have been developed for potential use in the Advanced Stirling Radioisotope Generator. The methods developed avoid the complexity and extra mass inherent in data extraction from multiple sensors or the use of shielding. This paper discusses these methods, and also provides experimental data obtained during breadboard testing of both AC and DC external magnetic field devices.

  3. Prevalence of information stored in arrays of magnetic nanowires against external fields

    Science.gov (United States)

    Ceballos, D.; Cisternas, E.; Vogel, E. E.; Allende, S.

    2018-04-01

    Arrays of magnetic nanowires in porous alumina can be used to store information inscribed on the system by orienting the magnetization of selected wires pointing in a desired direction, so symbols can be read as ferromagnetic sectors. However, this information is subject to aging and the stored information could be gradually lost. We investigate here two mechanisms proposed to improve the prevalence of the stored information: opposite ferromagnetic band at the center of the symbol and bi-segmented nanowires acting as two layers of nanowires storing the same information. Both mechanisms prove to increase resistance to the action of external magnetic fields for the case of Ni wires in a geometry compatible with actually grown nanowires. Advantages and disadvantages of these mechanisms are discussed.

  4. Environmental externalities: Applying the concept to Asian coal-based power generation. [Includes external environmental and societal costs and methods of evaluating them

    Energy Technology Data Exchange (ETDEWEB)

    Szpunar, C.B.; Gillette, J.L.

    1993-03-01

    This report examines the concept of environmental externality. It discusses various factors -- the atmospheric transformations, relationship of point-source emissions to ambient air quality, dose-response relationships, applicable cause-and-effect principles, and risk and valuation research -- that are considered by a number of state utilities when they apply the environmental externality concept to energy resource planning. It describes a methodology developed by Argonne National Laboratory for general use in resource planning, in combination with traditional methods that consider the cost of electricity production. Finally, it shows how the methodology can be applied in Indonesia, Thailand, and Taiwan to potential coal-fired power plant projects that will make use of clean coal technologies.

  5. Influence of the maximum applied magnetic field on the angular dependence of Magnetic Barkhausen Noise in API5L steels

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Ortiz, P. [Laboratorio de Evaluación No Destructiva Electromagnética (LENDE), ESIME-SEPI, Edif. Z-4, Instituto Politécnico Nacional, Zacatenco, México D.F. (Mexico); Pérez-Benítez, J.A., E-mail: japerezb@ipn.mx [Laboratorio de Evaluación No Destructiva Electromagnética (LENDE), ESIME-SEPI, Edif. Z-4, Instituto Politécnico Nacional, Zacatenco, México D.F. (Mexico); Espina-Hernández, J.H. [Laboratorio de Evaluación No Destructiva Electromagnética (LENDE), ESIME-SEPI, Edif. Z-4, Instituto Politécnico Nacional, Zacatenco, México D.F. (Mexico); Caleyo, F. [Departamento de Ingeniería Metalúrgica, ESIQIE, UPALM Edif. 7, Instituto Politécnico Nacional, Zacatenco, C.P. 07738 México D.F. (Mexico); Mehboob, N.; Grössinger, R. [Institute of Solid State Physics, Vienna University of Technology, Vienna A-1040 (Austria); Hallen, J.M. [Departamento de Ingeniería Metalúrgica, ESIQIE, UPALM Edif. 7, Instituto Politécnico Nacional, Zacatenco, C.P. 07738 México D.F. (Mexico)

    2016-03-01

    This work studies the influence of the maximum applied magnetic field on the angular dependence of the energy of the Magnetic Barkhausen Noise signal in three different API5L pipeline steels. The results show that the shape of the angular dependence of the Magnetic Barkhausen Noise energy changes with the increase of the amplitude of the applied magnetic field. This phenomenon is a consequence of the presence of unlike magnetization processes at different magnitudes of the applied magnetic field. The outcomes reveal the importance of controlling the value of the maximum applied field as parameter for the improvement of the MBN angular dependence measurements. - Highlights: • Study the angular dependence of MBN with applied field in three pipeline steels. • Reveals the change of this angular dependence with the increase applied field. • Explains this dependence based on the domain wall dynamics theory.

  6. Influence of the maximum applied magnetic field on the angular dependence of Magnetic Barkhausen Noise in API5L steels

    International Nuclear Information System (INIS)

    Martínez-Ortiz, P.; Pérez-Benítez, J.A.; Espina-Hernández, J.H.; Caleyo, F.; Mehboob, N.; Grössinger, R.; Hallen, J.M.

    2016-01-01

    This work studies the influence of the maximum applied magnetic field on the angular dependence of the energy of the Magnetic Barkhausen Noise signal in three different API5L pipeline steels. The results show that the shape of the angular dependence of the Magnetic Barkhausen Noise energy changes with the increase of the amplitude of the applied magnetic field. This phenomenon is a consequence of the presence of unlike magnetization processes at different magnitudes of the applied magnetic field. The outcomes reveal the importance of controlling the value of the maximum applied field as parameter for the improvement of the MBN angular dependence measurements. - Highlights: • Study the angular dependence of MBN with applied field in three pipeline steels. • Reveals the change of this angular dependence with the increase applied field. • Explains this dependence based on the domain wall dynamics theory.

  7. The Effect of External Magnetic Fields on the MRT Instability in MagLIF

    Science.gov (United States)

    Hess, Mark; Peterson, Kyle; Weis, Matthew; Lau, Yue Ying

    2014-10-01

    Recent experiments on MagLIF which incorporate an external B-field suggest that the MRT instability within the liner has a different behavior than without the B-field. Previous work by Chandrasekhar and Harris have illustrated how the MRT growth rate, assuming fixed liner density and fixed acceleration, can change due to the presence of an external B-field. In this work, we show how the growth rate of the MRT instability is dynamically affected by the rapidly varying acceleration, liner density, and surface magnetic field, which is composed of the external B-field and the drive B-field of the liner in the MagLIF experiments. In addition, we also examine the effects of finite liner resistivity on MRT growth, which gives rise to an additional time scale corresponding to magnetic diffusion. We discuss the implications of this result for future MagLIF designs. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.

  8. High-pressure Moessbauer spectroscopy of perovskite high valence iron oxides under external magnetic field

    International Nuclear Information System (INIS)

    Kawakami, Takateru; Nasu, Saburo

    2005-01-01

    The magnetic properties of SrFeO 3 (SFO), CaFeO 3 (CFO) and Sr 2/3 La 1/3 FeO 3 (SLFO), which are perovskite iron oxides with a high valence state of Fe, have been investigated by high-pressure Moessbauer spectroscopy under external magnetic field. These perovskite oxides have been found to switch electronic ground state drastically from the antiferromagnetic (AF) state to the ferromagnetic (FM) state under high pressure. CFO and SLFO, which show a charge-disproportionation (CD: 2Fe 4+ → Fe 3+ + Fe 5+ and 3Fe 11/3+ → 2Fe 3+ + Fe 5+ , respectively) at low temperature, switch magnetic ordering from the AF state to the FM state simultaneously with the suppression of the CD in a critical pressure of about 19 and 23 GPa, respectively. SFO, which does not show any CD, switches its magnetic ordering from the AF state to the FM state at about 7 GPa. These pressure-induced transitions from the AF state to the FM state are accompanied by the discontinuous reduction of the magnetic hyperfine fields

  9. Sensitivity of total stress to changes in externally applied water pressure in KBS-3 buffer bentonite

    International Nuclear Information System (INIS)

    Harrington, J.F.; Birchall, D.J.

    2007-04-01

    In the current Swedish repository design concept, composite copper and steel canisters containing spent nuclear fuel will be placed in large diameter disposal boreholes drilled into the floor of the repository tunnels. The space around each canister will be filled with pre-compacted bentonite which over time will draw in the surrounding ground water and swell, closing up any construction joints. However, for the purposes of performance assessment, it is necessary to consider the effect of glacial loading of a future repository and its impact on the mechanical behaviour of the bentonite, in particular, the sensitivity of total stress to changes in porewater pressure (backpressure). Two experimental histories have been undertaken using a custom-designed constant volume and radial flow (CVRF) apparatus. In both tests backpressure was varied in a number of incremental and decremental cycles while total stress, porewater pressure and volumetric flow rate were continuously monitored. The swelling pressure of the buffer clay at dry densities of 1.8 Mg/m 3 and 1.61 Mg/m 3 was determined to be around 5.5 MPa and 7.2 MPa respectively. For initial ascending porewater pressure histories the average proportionality factor α ranged from 0.86 and 0.92. Data exhibited a general trend of increasing α with increasing backpressure. In test Mx80-11 this was supported by analysis of the water inflow data which indicated a reduction in system compressibility. Asymptotic values of porewater pressure within the clay are in good agreement with externally applied backpressure values. Inspection of data provides no evidence for the development of hydraulic thresholds within the clay, subject to the boundary conditions of this test geometry. Analysis of the stress data demonstrates significant hysteresis between ascending and descending porewater pressure histories. The amount of hysteresis appears to be linked to the magnitude of the backpressure applied to the specimen, suggesting some

  10. Anomalous diffusion process applied to magnetic resonance image enhancement

    Science.gov (United States)

    Senra Filho, A. C. da S.; Garrido Salmon, C. E.; Murta Junior, L. O.

    2015-03-01

    Diffusion process is widely applied to digital image enhancement both directly introducing diffusion equation as in anisotropic diffusion (AD) filter, and indirectly by convolution as in Gaussian filter. Anomalous diffusion process (ADP), given by a nonlinear relationship in diffusion equation and characterized by an anomalous parameters q, is supposed to be consistent with inhomogeneous media. Although classic diffusion process is widely studied and effective in various image settings, the effectiveness of ADP as an image enhancement is still unknown. In this paper we proposed the anomalous diffusion filters in both isotropic (IAD) and anisotropic (AAD) forms for magnetic resonance imaging (MRI) enhancement. Filters based on discrete implementation of anomalous diffusion were applied to noisy MRI T2w images (brain, chest and abdominal) in order to quantify SNR gains estimating the performance for the proposed anomalous filter when realistic noise is added to those images. Results show that for images containing complex structures, e.g. brain structures, anomalous diffusion presents the highest enhancements when compared to classical diffusion approach. Furthermore, ADP presented a more effective enhancement for images containing Rayleigh and Gaussian noise. Anomalous filters showed an ability to preserve anatomic edges and a SNR improvement of 26% for brain images, compared to classical filter. In addition, AAD and IAD filters showed optimum results for noise distributions that appear on extreme situations on MRI, i.e. in low SNR images with approximate Rayleigh noise distribution, and for high SNR images with Gaussian or non central χ noise distributions. AAD and IAD filter showed the best results for the parametric range 1.2 MRI. This study indicates the proposed anomalous filters as promising approaches in qualitative and quantitative MRI enhancement.

  11. The orientation of the neuronal growth process can be directed via magnetic nanoparticles under an applied magnetic field.

    Science.gov (United States)

    Riggio, Cristina; Calatayud, M Pilar; Giannaccini, Martina; Sanz, Beatriz; Torres, Teobaldo E; Fernández-Pacheco, Rodrigo; Ripoli, Andrea; Ibarra, Manuel Ricardo; Dente, Luciana; Cuschieri, Alfred; Goya, Gerardo F; Raffa, Vittoria

    2014-10-01

    There is a growing body of evidence indicating the importance of physical stimuli for neuronal growth and development. Specifically, results from published experimental studies indicate that forces, when carefully controlled, can modulate neuronal regeneration. Here, we validate a non-invasive approach for physical guidance of nerve regeneration based on the synergic use of magnetic nanoparticles (MNPs) and magnetic fields (Ms). The concept is that the application of a tensile force to a neuronal cell can stimulate neurite initiation or axon elongation in the desired direction, the MNPs being used to generate this tensile force under the effect of a static external magnetic field providing the required directional orientation. In a neuron-like cell line, we have confirmed that MNPs direct the neurite outgrowth preferentially along the direction imposed by an external magnetic field, by inducing a net angle displacement (about 30°) of neurite direction. From the clinical editor: This study validates that non-invasive approaches for physical guidance of nerve regeneration based on the synergic use of magnetic nanoparticles and magnetic fields are possible. The hypothesis was confirmed by observing preferential neurite outgrowth in a cell culture system along the direction imposed by an external magnetic field. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Laser-Plasma Interaction in Presence of an Obliquely External Magnetic Field: Application to Laser Fusion without Radioactivity

    Science.gov (United States)

    Mobaraki, M.; Jafari, S.

    2016-08-01

    In this paper, the nonlinear interaction of ultra-high power laser beam with fusion plasma at relativistic regime in the presence of obliquely external magnetic Geld has been studied. Imposing an external magnetic Geld on plasma can modify the density profile of the plasma so that the thermal conductivity of electrons reduces which is considered to be the decrease of the threshold energy for ignition. To achieve the fusion of Hydrogen-Boron (HB) fuel, the block acceleration model of plasma is employed. Energy production by HB isotopes can be of interest, since its reaction does not generate radioactive tritium. By using the inhibit factor in the block model acceleration of plasma and Maxwell's as well as the momentum transfer equations, the electron density distribution and dielectric permittivity of the plasma medium are obtained. Numerical results indicate that with increasing the intensity of the external magnetic field, the oscillation of the laser magnetic field decreases, while the dielectric permittivity increases. Moreover, the amplitude of the electron density becomes highly peaked and the plasma electrons are strongly bunched with increasing the intensity of external magnetic field. Therefore, the magnetized plasma can act as a positive focusing lens to enhance the fusion process. Besides, we find that with increasing θ-angle (from oblique external magnetic field) between 0 and 90°, the dielectric permittivity increases, while for θ between 90° and 180°, the dielectric permittivity decreases with increasing θ.

  13. Influence of external magnetic field on laser-induced gold nanoparticles fragmentation

    International Nuclear Information System (INIS)

    Serkov, A. A.; Rakov, I. I.; Simakin, A. V.; Kuzmin, P. G.; Shafeev, G. A.; Mikhailova, G. N.; Antonova, L. Kh.; Troitskii, A. V.; Kuzmin, G. P.

    2016-01-01

    Laser-assisted fragmentation is an efficient method of the nanoparticles size and morphology control. However, its exact mechanisms are still under consideration. One of the remaining problems is the plasma formation, inevitably occurring upon the high intensity laser irradiation. In this Letter, the role of the laser-induced plasma is studied via introduction of high-intensity external magnetic field (up to 7.5 T). Its presence is found to cause the plasma emission to start earlier regarding to a laser pulse, also increasing the plume luminosity. Under these conditions, the acceleration of nanoparticles fragmentation down to a few nanometers is observed. Laser-induced plasma interaction with magnetic field and consequent energy transfer from plasma to nanoparticles are discussed.

  14. Ferrofluid convective heat transfer under the influence of external magnetic source

    Directory of Open Access Journals (Sweden)

    M. Sheikholeslami

    2018-03-01

    Full Text Available Ferrofluid convective heat transfer in a cavity with sinusoidal cold wall is examined under the influence of external magnetic source. The working fluid is Fe3O4-water nanofluid. Single phase model is used to estimate the behavior of nanofluid. Vorticity stream function formulation is utilized to eliminate pressure gradient source terms. New numerical method is chosen namely Control volume base finite element method. Influences of Rayleigh, Hartmann numbers, amplitude of the sinusoidal wall and volume fraction of Fe3O4 on hydrothermal characteristics are presented. Results indicate that temperature gradient enhances as space between cold and hot walls reduces at low buoyancy force. Lorentz forces cause the nanofluid velocity to reduce and augment the thermal boundary layer thickness. Nusselt number augments with rise of buoyancy forces but it decreases with augment of Lorentz forces. Keywords: Nanofluid, Natural convection, Magnetic source, CVFEM, Sinusoidal wall

  15. A model of the response of GMR of metallic multilayers to external magnetic field

    Directory of Open Access Journals (Sweden)

    Uba J.I.

    2015-12-01

    Full Text Available It has not been possible to transform resistivity models in terms of magnetic field in order to account for variation of giant magnetoresistance (GMR with external magnetic field, which would have led to determination of material properties. This problem is approached mathematically via variation calculus to arrive at an exponential function that fits observed GMR values. Using this model in free electron approximation, the mean Fermi vector, susceptibility and total density of states of a number of metallic multilayers are determined from their reported GMR values. Susceptibility is found to depend on interface roughness and antiferromagnetic (AF coupling; thus, it gives qualitative measure of interface quality and AF coupling. Comparison of susceptibilities and GMRs of electrodeposited and ion beam sputtered Co/Cu structures shows that a rough interface suppresses GMR in the former but enhances it in the latter.

  16. Influence of external magnetic field on laser-induced gold nanoparticles fragmentation

    Energy Technology Data Exchange (ETDEWEB)

    Serkov, A. A. [Wave Research Center of A.M. Prokhorov General Physics Institute of the Russian Academy of Sciences, 38, Vavilov Street, 119991 Moscow (Russian Federation); The Federal State Educational Institution of Higher Professional Education, “Moscow Institute of Physics and Technology (State University),” 9, Institutsky lane, Dolgoprudny, 141700 Moscow (Russian Federation); Rakov, I. I.; Simakin, A. V.; Kuzmin, P. G. [Wave Research Center of A.M. Prokhorov General Physics Institute of the Russian Academy of Sciences, 38, Vavilov Street, 119991 Moscow (Russian Federation); Shafeev, G. A. [Wave Research Center of A.M. Prokhorov General Physics Institute of the Russian Academy of Sciences, 38, Vavilov Street, 119991 Moscow (Russian Federation); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31, Kashirskoye Highway, 115409 Moscow (Russian Federation); Mikhailova, G. N.; Antonova, L. Kh.; Troitskii, A. V.; Kuzmin, G. P. [A.M. Prokhorov General Physics Institute of the Russian Academy of Sciences, 38, Vavilov Street, 119991 Moscow (Russian Federation)

    2016-08-01

    Laser-assisted fragmentation is an efficient method of the nanoparticles size and morphology control. However, its exact mechanisms are still under consideration. One of the remaining problems is the plasma formation, inevitably occurring upon the high intensity laser irradiation. In this Letter, the role of the laser-induced plasma is studied via introduction of high-intensity external magnetic field (up to 7.5 T). Its presence is found to cause the plasma emission to start earlier regarding to a laser pulse, also increasing the plume luminosity. Under these conditions, the acceleration of nanoparticles fragmentation down to a few nanometers is observed. Laser-induced plasma interaction with magnetic field and consequent energy transfer from plasma to nanoparticles are discussed.

  17. GLYCOHEMOGLOBIN - COMPARISON OF 12 ANALYTICAL METHODS, APPLIED TO LYOPHILIZED HEMOLYSATES BY 101 LABORATORIES IN AN EXTERNAL QUALITY ASSURANCE PROGRAM

    NARCIS (Netherlands)

    WEYKAMP, CW; PENDERS, TJ; MUSKIET, FAJ; VANDERSLIK, W

    Stable lyophilized ethylenediaminetetra-acetic acid (EDTA)-blood haemolysates were applied in an external quality assurance programme (SKZL, The Netherlands) for glycohaemoglobin assays in 101 laboratories using 12 methods. The mean intralaboratory day-to-day coefficient of variation (CV),

  18. Transport coefficients and orientational distributions of dilute colloidal dispersions composed of hematite particles (for an external magnetic field parallel to the angular velocity vector of simple shear flow)

    Science.gov (United States)

    Satoh, Akira; Hayasaka, Ryo; Majima, Tamotsu

    We have treated a dilute dispersion composed of ferromagnetic rodlike particles with a magnetic moment normal to the particle axis, such as hematites, to investigate the influences of the magnetic field strength, shear rate, and random forces on the orientational distribution of rodlike particles and also on transport coefficients, such as viscosity and diffusion coefficient. In the present analysis, these rodlike particles are assumed to conduct the rotational Brownian motion in a simple shear flow as well as an external magnetic field. The results obtained here are summarized as follows. In the case of a strong magnetic field and a smaller shear rate, the rodlike particle can freely rotate in the xy-plane with the magnetic moment continuing to point the magnetic field direction. On the other hand, for a strong shear flow, the particle has a tendency to incline in the flow direction with the magnetic moment pointing to the magnetic field direction. In the case of the magnetic field applied normal to the direction of the sedimentation, the diffusion coefficient gives rise to smaller values than expected, since the rodlike particle sediments with the particle axis inclining toward directions normal to the movement direction and, of course, toward the direction along that direction.

  19. Cervical external immobilization devices: evaluation of magnetic resonance imaging issues at 3.0 Tesla.

    Science.gov (United States)

    Diaz, Francis L; Tweardy, Lisa; Shellock, Frank G

    2010-02-15

    Laboratory investigation, ex vivo. Currently, no studies have addressed the magnetic resonance imaging (MRI) issues for cervical external immobilization devices at 3-Tesla. Under certain conditions significant heating may occur, resulting in patient burns. Furthermore, artifacts can be substantial and prevent the diagnostic use of MRI. Therefore, the objective of this investigation was to evaluate MRI issues for 4 different cervical external immobilization devices at 3-Tesla. Excessive heating and substantial artifacts are 2 potential complications associated with performing MRI at 3-Tesla in patients with cervical external immobilization devices. Using ex vivo testing techniques, MRI-related heating and artifacts were evaluated for 4 different cervical devices during MRI at 3-Tesla. Four cervical external immobilization devices (Generation 80, Resolve Ring and Superstructure, Resolve Ring and Jerome Vest/Jerome Superstructure, and the V1 Halo System; Ossur Americas, Aliso Viejo, CA) underwent MRI testing at 3-Tesla. All devices were made from nonmetallic or nonmagnetic materials. Heating was determined using a gelled-saline-filled skull phantom with fluoroptic thermometry probes attached to the skull pins. MRI was performed at 3-Tesla, using a high level of RF energy. Artifacts were assessed at 3-Tesla, using standard cervical imaging techniques. The Generation 80 and V1 Halo devices exhibited substantial temperature rises (11.6 degrees C and 8.5 degrees C, respectively), with "sparking" evident for the Generation 80 during the MRI procedure. Artifacts were problematic for these devices, as well. By comparison, the 2 Resolve Ring-based cervical external immobilization devices showed little or no heating (Tesla.

  20. External confinement and surface modes in magnetized force-free jets

    Science.gov (United States)

    Sobacchi, E.; Lyubarsky, Y. E.

    2018-01-01

    In the paradigm of magnetic launching of astrophysical jets, instabilities in the magnetohydrodynamic (MHD) flow are a good candidate to convert the Poynting flux into the kinetic energy of the plasma. If the magnetized plasma fills the almost entire space, the jet is unstable to helical perturbations of its body. However, the growth rate of these modes is suppressed when the poloidal component of the magnetic field has a vanishing gradient, which may be the actual case for a realistic configuration. Here we show that, if the magnetized plasma is confined into a limited region by the pressure of some external medium, the velocity shear at the contact surface excites unstable modes which can affect a significant fraction of the jet's body. We find that when the Lorentz factor of the jet is Γ ∼ 10 (Γ ∼ 100), these perturbations typically develop after propagating along the jet for tens (hundreds) of jet's radii. Surface modes may therefore play an important role in converting the energy of the jet from the Poynting flux to the kinetic energy of the plasma, particularly in active galactic nuclei. The scaling of the dispersion relation with (i) the angular velocity of the field lines and (ii) the sound speed in the confining gas is discussed.

  1. Rare-earth magnets applied to liquid metal flow

    International Nuclear Information System (INIS)

    Borges, E.M.; Sircilli Neto, F.; Passaro, A.

    1996-01-01

    The operation of electromagnetic pumps used to control liquid metal flow are based on the Lorentz force. In this work, it is studied the design of an electromagnetic pump substituting the C-type magnet used in a prototype built previously by Sm Co 5 permanent magnets. The results of the computational simulation indicate that the new pump can develop manometric pressure comparable to the previous prototype and also has smaller dimensions. Magnetic field measurement agreed with the magnetic simulation in the region of interest. (author)

  2. Surface flux density distribution characteristics of bulk high-T c superconductor in external magnetic field

    International Nuclear Information System (INIS)

    Nishikawa, H.; Torii, S.; Yuasa, K.

    2005-01-01

    This paper describes the measured results of the two-dimensional flux density distribution of a YBCO bulk under applied AC magnetic fields with various frequency. Melt-processed oxide superconductors have been developed in order to obtain strong pinning forces. Various electric mechanical systems or magnetic levitation systems use those superconductors. The major problem is that cracks occur because the bulk superconductors are brittle. The bulk may break in magnetizing process after cracks make superconducting state instable. The trapped flux density and the permanent current characteristics of bulk superconductors have been analyzed, so as to examine the magnetizing processes or superconducting states of the bulk. In those studies, the two-dimensional surface flux density distributions of the bulk in static fields are discussed. On the other hand, the distributions in dynamic fields are little discussed. We attempted to examine the states of the bulk in the dynamic fields, and made a unique experimental device which has movable sensors synchronized with AC applied fields. As a result, the two-dimensional distributions in the dynamic fields are acquired by recombining the one-dimensional distributions. The dynamic states of the flux of the bulk and the influences of directions of cracks are observed from the distributions. In addition, a new method for measuring two-dimensional flux density distribution under dynamic magnetic fields is suggested

  3. Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, C. Scott; Haill, Thomas A.; Dalton, Devon Gardner; Rovang, Dean Curtis; Lamppa, Derek C.

    2013-09-01

    The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated.

  4. Effect of a static external magnetic perturbation on resistive mode stability in tokamaks

    International Nuclear Information System (INIS)

    Fitzpatrick, R.

    1994-03-01

    The influence of a general static external magnetic perturbation on the stability of resistive modes in a tokamak plasma is examined. There are three main parts to this investigation. Firstly, the vacuum perturbation is expanded as a set of well-behaved toroidal ring functions and is, thereafter, specified by the coefficients of this expansion. Secondly, a dispersion relation is derived for resistive plasma instabilities in the presence of a general external perturbation and finally, this dispersion relation is solved for the amplitudes of the tearing and twisting modes driven in the plasma by a specific perturbation. It is found that the amplitudes of driven tearing and twisting modes are negligible until a certain critical perturbation strength is exceeded. Only tearing modes are driven in low-β plasmas with εβ p p ∼>1. For error-field perturbations made up of a large number of different poloidal and toroidal harmonics the critical strength to drive locked modes has a open-quote staircase close-quote variation with edge-q, characterized by strong discontinuities as coupled rational surfaces enter or leave the plasma. For single harmonic perturbations the variation with edge-q is far smoother. Both types of behaviour have been observed experimentally. The critical perturbation strength is found to decrease strongly close to an ideal external kink stability boundary. This is also in agreement with experimental observations

  5. Kink Waves in Non-isothermal Stratified Solar Waveguides: Effect of the External Magnetic Field

    Energy Technology Data Exchange (ETDEWEB)

    Lopin, I. [Ussuriisk Astrophysical Observatory, Russian Academy of Sciences (Russian Federation); Nagorny, I., E-mail: lopin78@mail.ru [Institute of Automation and Control Processes FEB RAS, Vladivostok (Russian Federation)

    2017-10-01

    We study the effect of an external magnetic field on the properties of kink waves, propagating along a thin non-isothermal stratified and diverging magnetic flux tube. A wave equation, governing the propagation of kink waves under the adopted model is derived. It is shown that the vertical gradient of temperature introduces a spatially local cut-off frequency ω {sub c}. The vertical distribution of the cut-off frequency is calculated for the reference VAL-C model of the solar atmosphere and for different values of a ratio of external to internal magnetic fields. The results show that the cut-off frequency is negative below the temperature minimum due to the negative temperature gradient. In the chromosphere the cut-off frequency at a given height is smaller for a stronger external magnetic field. For the appropriate range of a ratio B{sub e} / B{sub i}  ≈ 0–0.8, the cutoff lies in the range ω{sub c}  ≈ 0.003–0.010 s{sup −1} (periods 600 < P{sub c} < 2000 s). The estimate of the cut-off frequency in the transition region is provided as well. In the propagating wave regime, the effective wave energy flux in the non-isothermal diverging flux tubes is the same as in the straight and homogeneous cylindrical waveguides. The obtained wave equation in the limit β  = 0 is used to study the kink oscillations of non-isothermal coronal loops. It is found that the gradient of temperature along the coronal loops reduces the frequency ratio of the first overtone to the fundamental mode, i.e., ω{sub 2}/ ω{sub 1} < 2. This reduction grows for a larger ratio of temperature at the loop top to the temperature at the footpoints. Moreover, the effect of reduction is most pronounced for the steeper temperature profiles.

  6. Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.

    Science.gov (United States)

    Luechinger, Roger; Boesiger, Peter; Disegi, John A

    2007-07-01

    Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated. Copyright 2006 Wiley Periodicals, Inc.

  7. A Conceptual Framework for Error Remediation with Multiple External Representations Applied to Learning Objects

    Science.gov (United States)

    Leite, Maici Duarte; Marczal, Diego; Pimentel, Andrey Ricardo; Direne, Alexandre Ibrahim

    2014-01-01

    This paper presents the application of some concepts of Intelligent Tutoring Systems (ITS) to elaborate a conceptual framework that uses the remediation of errors with Multiple External Representations (MERs) in Learning Objects (LO). To this is demonstrated a development of LO for teaching the Pythagorean Theorem through this framework. This…

  8. 3T magnetic resonance imaging testing of externally programmable shunt valves.

    Science.gov (United States)

    Zabramski, Joseph M; Preul, Mark C; Debbins, Josef; McCusker, Daniel J

    2012-01-01

    Exposure of externally programmable shunt-valves (EPS-valves) to magnetic resonance imaging (MRI) may lead to unexpected changes in shunt settings, or affect the ability to reprogram the valve. We undertook this study to examine the effect of exposure to a 3T MRI on a group of widely used EPS-valves. Evaluations were performed on first generation EPS-valves (those without a locking mechanism to prevent changes in shunt settings by external magnets other than the programmer) and second generation EPS-valves (those with a locking mechanisms). Fifteen new shunt-valves were divided into five groups of three identical valves each, and then exposed to a series of six simulated MRI scans. After each of the exposures, the valves were evaluated to determine if the valve settings had changed, and whether the valves could be reprogrammed. The study produced 18 evaluations for each line of shunt-valves. Exposure of the first generation EPS-valves to a 3T magnetic field resulted in frequent changes in the valve settings; however, all valves retained their ability to be reprogrammed. Repeated exposure of the second generation EPS-valves has no effect on shunt valve settings, and all valves retained their ability to be interrogated and reprogrammed. Second generation EPS-valves with locking mechanisms can be safely exposed to repeated 3T MRI systems, without evidence that shunt settings will change. The exposure of the first generation EPS-valves to 3T MRI results in frequent changes in shunt settings that necessitate re-evaluation soon after MRI to avoid complications.

  9. Impacts Of External Price Shocks On Malaysian Macro Economy-An Applied General Equilibrium Analysis

    Directory of Open Access Journals (Sweden)

    Abul Quasem Al-Amin

    2008-10-01

    Full Text Available This paper examines the impacts of external price shocks in the Malaysian economy. There are three simulations are carried out with different degrees of external shocks using Malaysian Social Accounting Matrix (SAM and Computable General Equilibrium (CGE analysis. The model results indicate that the import price shocks, better known as external price shocks by 15% decreases the domestic production of building and construction sector by 25.87%, hotels, restaurants and entertainment sector by 12.04%, industry sector by 12.02%, agriculture sector by 11.01%, and electricity and gas sector by 9.55% from the baseline. On the import side, our simulation results illustrate that as a result of the import price shocks by 15%, imports decreases significantly in all sectors from base level. Among the scenarios, the largest negative impacts goes on industry sectors by 29.67% followed by building and construction sector by 22.42%, hotels, restaurants and entertainment sector by 19.45%, electricity and gas sector by 13.%, agriculture sector by 12.63% and other service sectors by 11.17%. However significant negative impact goes to the investment and fixed capital investment. It also causes the household income, household consumption and household savings down and increases the cost of livings in the economy results in downward social welfare.

  10. Applying torque to the Escherichia coli flagellar motor using magnetic tweezers

    OpenAIRE

    van Oene, M.M.; Dickinson, L.E.; Cross, B.; Pedaci, F.; Lipfert, J.; Dekker, N.H.

    2017-01-01

    The bacterial flagellar motor of Escherichia coli is a nanoscale rotary engine essential for bacterial propulsion. Studies on the power output of single motors rely on the measurement of motor torque and rotation under external load. Here, we investigate the use of magnetic tweezers, which in principle allow the application and active control of a calibrated load torque, to study single flagellar motors in Escherichia coli. We manipulate the external load on the motor by adjusting the magneti...

  11. Active magnetic bearings: As applied to centrifugal pumps

    Science.gov (United States)

    Nelik, Lev; Cooper, Paul; Jones, Graham; Galecki, Dennis; Pinckney, Frank; Kirk, Gordon

    1992-01-01

    Application of magnetic bearings to boiler feed pumps presents various attractive features, such as longer bearing life, lower maintenance costs, and improved operability through control of the rotordynamics. Magnetic bearings were fitted to an eight-stage, 600 hp boiler feed pump, which generates 2600 ft of heat at 680 gpm and 3560 rpm. In addition to the varied and severe operating environment in steady state operation of this pump in a power plant, it is also subjected to transient loads during frequent starts and stops. These loads can now be measured by the in-built instrumentation of the magnetic bearings. Following site installation, a follow-up bearing tune-up was performed, and pump transient response testing was conducted. The bearing response was completely satisfactory, ensuring trouble-free pump operation even in the range of reduced load. The experience gained so far through design and testing proves feasibility of magnetic bearings for boiler feed pumps, which sets the stage for application of even higher energy centrifugal pumps equipped with magnetic bearings.

  12. Applying Standard Industrial Components for Active Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Bert-Uwe Koehler

    2017-02-01

    Full Text Available With the increasing number of active magnetic bearing applications, satisfying additional requirements is becoming increasingly more important. As for every technology, moving away from being a niche product and achieving a higher level of maturity, these requirements relate to robustness, reliability, availability, safety, security, traceability, certification, handling, flexibility, reporting, costs, and delivery times. Employing standard industrial components, such as those from flexible modular motion control drive systems, is an approach that allows these requirements to be satisfied while achieving rapid technological innovation. In this article, we discuss technical and non-technical aspects of using standard industrial components in magnetic bearing applications.

  13. Behaviour of the order parameter of the simple magnet in an external field

    Directory of Open Access Journals (Sweden)

    M.P.Kozlovskii

    2005-01-01

    Full Text Available The effect of a homogeneous external field on the three-dimensional uniaxial magnet behaviour near the critical point is investigated within the framework of the nonperturbative collective variables method using the ρ4 model. The research is carried out for the low-temperature region. The analytic explicit expressions for the free energy, average spin moment and susceptibility are obtained for weak and strong fields in comparison with the field value belonging to the pseudocritical line. The calculations are performed on the microscopic level without any adjusting parameters. It is established that the long-wave fluctuations of the order parameter play a crucial role in forming a crossover between the temperature-dependence and field-dependence critical behaviour of the system.

  14. Studies on entanglement entropy for Hubbard model with hole-doping and external magnetic field

    International Nuclear Information System (INIS)

    Yao, K.L.; Li, Y.C.; Sun, X.Z.; Liu, Q.M.; Qin, Y.; Fu, H.H.; Gao, G.Y.

    2005-01-01

    By using the density matrix renormalization group (DMRG) method for the one-dimensional (1D) Hubbard model, we have studied the von Neumann entropy of a quantum system, which describes the entanglement of the system block and the rest of the chain. It is found that there is a close relation between the entanglement entropy and properties of the system. The hole-doping can alter the charge-charge and spin-spin interactions, resulting in charge polarization along the chain. By comparing the results before and after the doping, we find that doping favors increase of the von Neumann entropy and thus also favors the exchange of information along the chain. Furthermore, we calculated the spin and entropy distribution in external magnetic filed. It is confirmed that both the charge-charge and the spin-spin interactions affect the exchange of information along the chain, making the entanglement entropy redistribute

  15. Energy level splitting and luminescence enhancement in AlN:Er by an external magnetic field

    Science.gov (United States)

    Maqbool, Muhammad; Ahmad, Iftikhar; Ali, Ghafar; Maaz, Khan

    2015-08-01

    Sputter deposited thin film AlN:Er (1 at.%) emits at 554 nm and 561 nm as a result of 2H11/2→ 4I15/2 and 4S3/2→ 4I15/2 transitions under 532 nm NdYAG laser and 783.3 nm crystal laser excitation. An external magnetic field of 0.1 T enhances the green emission and splits the 4S3/2 energy level in two sub-levels with a difference of 0.013 eV. The splitting of energy level produces new emission from Er3+ with a wavelength of 564.5 nm. Infrared emission is also observed at 1552 nm as a result of 4I13/2→ 4I15/2 transition. Enhanced luminescence shows the suitability of Er3+ for high efficiency optical devices.

  16. Topological phases of silicene and germanene in an external magnetic field: Quantitative results

    KAUST Repository

    Singh, Nirpendra

    2014-03-17

    We investigate the topological phases of silicene and germanene that arise due to the strong spin-orbit interaction in an external perpendicular magnetic field. Below and above a critical field of 10 T, respectively, we demonstrate for silicene under 3% tensile strain quantum spin Hall and quantum anomalous Hall phases. Not far above the critical field, and therefore in the experimentally accessible regime, we obtain an energy gap in the meV range, which shows that the quantum anomalous Hall phase can be realized experimentally in silicene, in contrast to graphene (tiny energy gap) and germanene (enormous field required). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Population and phase dynamics of F=1 spinor condensates in an external magnetic field

    International Nuclear Information System (INIS)

    Romano, D.R.; Passos, E.J.V. de

    2004-01-01

    We show that the classical dynamics underlying the mean-field description of homogeneous mixtures of spinor F=1 Bose-Einstein condensates in an external magnetic field is integrable as a consequence of number conservation and axial symmetry in spin space. The population dynamics depends only on the quadratic term of the Zeeman energy and on the strength of the spin-dependent term of the atom-atom interaction. We determine the equilibrium populations as function of the ratio of these two quantities and the miscibility of the hyperfine components in the ground state spinors are thoroughly discussed. Outside the equilibrium, the populations are always a periodic function of time where the periodic motion can be a libration or a rotation. Our studies also indicate the absence of metastability

  18. Three dimensional boundary displacement due to stable ideal kink modes excited by external n = 2 magnetic perturbations

    Science.gov (United States)

    Willensdorfer, M.; Strumberger, E.; Suttrop, W.; Dunne, M.; Fischer, R.; Birkenmeier, G.; Brida, D.; Cavedon, M.; Denk, S. S.; Igochine, V.; Giannone, L.; Kirk, A.; Kirschner, J.; Medvedeva, A.; Odstrčil, T.; Ryan, D. A.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2017-11-01

    In low-collisionality (ν\\star) scenarios exhibiting mitigation of edge localized mode (ELMs), stable ideal kink modes at the edge are excited by externally applied magnetic perturbation (MP)-fields. In ASDEX Upgrade these modes can cause three-dimensional (3D) boundary displacements up to the centimeter range. These displacements have been measured using toroidally localized high resolution diagnostics and rigidly rotating n=2 MP-fields with various applied poloidal mode spectra. These measurements are compared to non-linear 3D ideal magnetohydrodynamics (MHD) equilibria calculated by VMEC. Comprehensive comparisons have been conducted, which consider for instance plasma movements due to the position control system, attenuation due to internal conductors and changes in the edge pressure profiles. VMEC accurately reproduces the amplitude of the displacement and its dependencies on the applied poloidal mode spectra. Quantitative agreement is found around the low field side (LFS) midplane. The response at the plasma top is qualitatively compared. The measured and predicted displacements at the plasma top maximize when the applied spectra is optimized for ELM-mitigation. The predictions from the vacuum modeling generally fails to describe the displacement at the LFS midplane as well as at the plasma top. When the applied mode spectra is set to maximize the displacement, VMEC and the measurements clearly surpass the predictions from the vacuum modeling by a factor of four. Minor disagreements between VMEC and the measurements are discussed. This study underlines the importance of the stable ideal kink modes at the edge for the 3D boundary displacement in scenarios relevant for ELM-mitigation.

  19. Assessment of Diaphragm and External Intercostals Fatigue from Surface EMG using Cervical Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    Ya-Ju Chang

    2008-03-01

    Full Text Available This study was designed: (1 to test the reliability of surface electromyography (sEMG recording of the diaphragm and external intercostals contractions response to cervical magnetic stimulation (CMS, (2 to examine the amount and the types of inspiratory muscle fatigue that developed after maximum voluntary ventilation (MVV maneuvers.Ten male college students without physical disability (22.1±2.0 years old participated in the study and each completed a control (quiet breathing trial and a fatigue (MVV maneuvers trial sequentially. In the quiet breathing trial, the subjects maintained quiet breathing for five minutes. The subjects performed five maximal static inspiratory efforts and received five CMS before and after the quiet breathing. In the MVV trial, subjects performed five maximal inspiratory efforts and received five CMS before, immediately after, and ten minutes after two sets of MVV maneuvers performed five minutes apart. Maximal inspiratory pressure (PImax, sEMG of diaphragm and external intercostals during maximal static inspiratory efforts and during CMS were recorded. In the quiet breathing trial, high intraclass correlation coefficients (ICC=0.95-0.99 were observed in all the variables. In the MVV trial, the PImax, the EMG amplitude and the median power frequency during maximal static inspiratory efforts significantly decreased in both the diaphragm and the external intercostals immediately after the MVV maneuvers Sensors 2008, 8 2175 (P 0.05. It is concluded that the sEMG recordings of the diaphragm during maximal static inspiratory efforts and in response to CMS allow reproducible sequential assessment of diaphragm contractility. MVV maneuvers resulted in inspiratory muscles fatigue, possibly central fatigue.

  20. Phase-Field simulation of phase decomposition in Fe-Cr-Co alloy under an external magnetic field

    Science.gov (United States)

    Koyama, Toshiyuki; Onodera, Hidehiro

    2004-07-01

    Phase decomposition during isothermal aging of a Fe-Cr-Co ternary alloy under an external magnetic field is simulated based on the phase-field method. In this simulation, since the Gibbs energy available from the thermodynamic CALPHAD database of the equilibrium phase diagram is employed as a chemical free energy, the present calculation provides the quantitative microstructure changes directly linked to the phase diagram. The simulated microstructure evolution demonstrates that the lamella like microstructure elongated along the external magnetic field is evolved with the progress of aging. The morphological and temporal developments of the simulated microstructures are in good agreement with experimental results that have been obtained for this alloy system.

  1. External control of the Drosophila melanogaster egg to imago development period by specific combinations of 3D low-frequency electric and magnetic fields.

    Science.gov (United States)

    Makarov, Vladimir I; Khmelinskii, Igor

    2016-01-01

    We report that the duration of the egg-to-imago development period of the Drosophila melanogaster, and the imago longevity, are both controllable by combinations of external 3-dimensional (3D) low-frequency electric and magnetic fields (LFEMFs). Both these periods may be reduced or increased by applying an appropriate configuration of external 3D LFEMFs. We report that the longevity of D. melanogaster imagoes correlates with the duration of the egg-to-imago development period of the respective eggs. We infer that metabolic processes in both eggs and imago are either accelerated (resulting in reduced time periods) or slowed down (resulting in increased time periods). We propose that external 3D LFEMFs induce electric currents in live systems as well as mechanical vibrations on sub-cell, whole-cell and cell-group levels. These external fields induce media polarization due to ionic motion and orientation of electric dipoles that could moderate the observed effects. We found that the longevity of D. melanogaster imagoes is affected by action of 3D LFEMFs on the respective eggs in the embryonic development period (EDP). We interpret this effect as resulting from changes in the regulation mechanism of metabolic processes in D. melanogaster eggs, inherited by the resulting imagoes. We also tested separate effects of either 3D electric or 3D magnetic fields, which were significantly weaker.

  2. First-principles calculation of transport property in nano-devices under an external magnetic field

    International Nuclear Information System (INIS)

    Chen Jingzhe; Zhang Jin; Han Rushan

    2008-01-01

    The mesoscopic quantum interference phenomenon (QIP) can be observed and behaves as the oscillation of conductance in nano-devices when the external magnetic field changes. Excluding the factor of impurities or defects, specific QIP is determined by the sample geometry. We have improved a first-principles method based on the matrix Green's function and the density functional theory to simulate the transport behaviour of such systems under a magnetic field. We have studied two kinds of QIP: universal conductance fluctuation (UCF) and Aharonov–Bohm effect (A–B effect). We find that the amplitude of UCF is much smaller than the previous theoretical prediction. We have discussed the origin of difference and concluded that due to the failure of ergodic hypothesis, the ensemble statistics is not applicable, and the conductance fluctuation is determined by the flux-dependent density of states (DOSs). We have also studied the relation between the UCF and the structure of sample. For a specific structure, an atomic circle, the A–B effect is observed and the origin of the oscillation is also discussed

  3. A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

    Science.gov (United States)

    Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A

    2016-10-01

    Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.

  4. Magnetic Amphiphilic Composites Applied for the Treatment of Biodiesel Wastewaters

    Directory of Open Access Journals (Sweden)

    Bruno R. S. Lemos

    2012-05-01

    Full Text Available In this work, new magnetic amphiphilic composites were prepared by chemical vapor deposition with ethanol on the surface of hydrophilic natural chrysotile matrix containing Fe catalyst. XRD, Raman, Mössbauer and SEM analyses suggest the formation of a complex nanostructured material composed of hydrophobic carbon nanotubes/nanofibers grown on the hydrophilic surface of the MgSi fiber mineral and the presence of Fe metallic nanoparticles coated by carbon. These nanostructured particles show amphiphilic properties and interact very well with both oil and aqueous phases. When added to emulsions the amphiphilic particles locate on the oil/water interface and, under a magnetic field, the oil droplets collapsed leading to the separation of the aqueous and oil phases. Preliminary work showed excellent results on the use of these particles to break wastewater emulsions in the biodiesel process.

  5. Parallel computation of automatic differentiation applied to magnetic field calculations

    International Nuclear Information System (INIS)

    Hinkins, R.L.; Lawrence Berkeley Lab., CA

    1994-09-01

    The author presents a parallelization of an accelerator physics application to simulate magnetic field in three dimensions. The problem involves the evaluation of high order derivatives with respect to two variables of a multivariate function. Automatic differentiation software had been used with some success, but the computation time was prohibitive. The implementation runs on several platforms, including a network of workstations using PVM, a MasPar using MPFortran, and a CM-5 using CMFortran. A careful examination of the code led to several optimizations that improved its serial performance by a factor of 8.7. The parallelization produced further improvements, especially on the MasPar with a speedup factor of 620. As a result a problem that took six days on a SPARC 10/41 now runs in minutes on the MasPar, making it feasible for physicists at Lawrence Berkeley Laboratory to simulate larger magnets

  6. Magnetic Amphiphilic Composites Applied for the Treatment of Biodiesel Wastewaters

    OpenAIRE

    Bruno R. S. Lemos; Ana Paula C. Teixeira; José D. Ardisson; Waldemar A. A. Macedo; Luis E. Fernandez-Outon; Camila C. Amorim; Flávia C. C. Moura; Rochel M. Lago

    2012-01-01

    In this work, new magnetic amphiphilic composites were prepared by chemical vapor deposition with ethanol on the surface of hydrophilic natural chrysotile matrix containing Fe catalyst. XRD, Raman, Mössbauer and SEM analyses suggest the formation of a complex nanostructured material composed of hydrophobic carbon nanotubes/nanofibers grown on the hydrophilic surface of the MgSi fiber mineral and the presence of Fe metallic nanoparticles coated by carbon. These nanostructured particles show am...

  7. Multicritical behavior of the antiferromagnetic Blume-Emery-Griffiths model with the repulsive biquadratic coupling in an external magnetic field

    International Nuclear Information System (INIS)

    Erdinc, Ahmet; Canko, Osman; Keskin, Mustafa

    2006-01-01

    We have studied the antiferromagnetic Blume-Emery-Griffiths model with the repulsive biquadratic coupling in an external magnetic field using the lowest approximation of the cluster variation method which is identical to the mean-field approximation. First, we have investigated the thermal variations of the sublattice magnetizations and obtained four different main topological types. Then, we have calculated the phase diagrams and five main different phase diagram topologies are found. Finally, the discussion and comparison of the phase diagrams are made

  8. Multicritical behavior of the antiferromagnetic Blume-Emery-Griffiths model with the repulsive biquadratic coupling in an external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Erdinc, Ahmet [Department of Physics, Erciyes University, 38039 Kayseri (Turkey); Canko, Osman [Department of Physics, Erciyes University, 38039 Kayseri (Turkey); Keskin, Mustafa [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: keskin@erciyes.edu.tr

    2006-06-15

    We have studied the antiferromagnetic Blume-Emery-Griffiths model with the repulsive biquadratic coupling in an external magnetic field using the lowest approximation of the cluster variation method which is identical to the mean-field approximation. First, we have investigated the thermal variations of the sublattice magnetizations and obtained four different main topological types. Then, we have calculated the phase diagrams and five main different phase diagram topologies are found. Finally, the discussion and comparison of the phase diagrams are made.

  9. Quantum Monte Carlo Calculations Applied to Magnetic Molecules

    Energy Technology Data Exchange (ETDEWEB)

    Engelhardt, Larry [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    We have calculated the equilibrium thermodynamic properties of Heisenberg spin systems using a quantum Monte Carlo (QMC) method. We have used some of these systems as models to describe recently synthesized magnetic molecules, and-upon comparing the results of these calculations with experimental data-have obtained accurate estimates for the basic parameters of these models. We have also performed calculations for other systems that are of more general interest, being relevant both for existing experimental data and for future experiments. Utilizing the concept of importance sampling, these calculations can be carried out in an arbitrarily large quantum Hilbert space, while still avoiding any approximations that would introduce systematic errors. The only errors are statistical in nature, and as such, their magnitudes are accurately estimated during the course of a simulation. Frustrated spin systems present a major challenge to the QMC method, nevertheless, in many instances progress can be made. In this chapter, the field of magnetic molecules is introduced, paying particular attention to the characteristics that distinguish magnetic molecules from other systems that are studied in condensed matter physics. We briefly outline the typical path by which we learn about magnetic molecules, which requires a close relationship between experiments and theoretical calculations. The typical experiments are introduced here, while the theoretical methods are discussed in the next chapter. Each of these theoretical methods has a considerable limitation, also described in Chapter 2, which together serve to motivate the present work. As is shown throughout the later chapters, the present QMC method is often able to provide useful information where other methods fail. In Chapter 3, the use of Monte Carlo methods in statistical physics is reviewed, building up the fundamental ideas that are necessary in order to understand the method that has been used in this work. With these

  10. Applying torque to the Escherichia coli flagellar motor using magnetic tweezers

    NARCIS (Netherlands)

    van Oene, M.M.; Dickinson, L.E.; Cross, B.; Pedaci, F.; Lipfert, J.; Dekker, N.H.

    2017-01-01

    The bacterial flagellar motor of Escherichia coli is a nanoscale rotary engine essential for bacterial propulsion. Studies on the power output of single motors rely on the measurement of motor torque and rotation under external load. Here, we investigate the use of magnetic tweezers, which in

  11. Voltage-controlled magnetization switching in MRAMs in conjunction with spin-transfer torque and applied magnetic field

    Science.gov (United States)

    Munira, Kamaram; Pandey, Sumeet C.; Kula, Witold; Sandhu, Gurtej S.

    2016-11-01

    Voltage-controlled magnetic anisotropy (VCMA) effect has attracted a significant amount of attention in recent years because of its low cell power consumption during the anisotropy modulation of a thin ferromagnetic film. However, the applied voltage or electric field alone is not enough to completely and reliably reverse the magnetization of the free layer of a magnetic random access memory (MRAM) cell from anti-parallel to parallel configuration or vice versa. An additional symmetry-breaking mechanism needs to be employed to ensure the deterministic writing process. Combinations of voltage-controlled magnetic anisotropy together with spin-transfer torque (STT) and with an applied magnetic field (Happ) were evaluated for switching reliability, time taken to switch with low error rate, and energy consumption during the switching process. In order to get a low write error rate in the MRAM cell with VCMA switching mechanism, a spin-transfer torque current or an applied magnetic field comparable to the critical current and field of the free layer is necessary. In the hybrid processes, the VCMA effect lowers the duration during which the higher power hungry secondary mechanism is in place. Therefore, the total energy consumed during the hybrid writing processes, VCMA + STT or VCMA + Happ, is less than the energy consumed during pure spin-transfer torque or applied magnetic field switching.

  12. Mechanisms of defibrillation by standing waves in the bidomain ventricular tissue with voltage applied in an external bath

    Science.gov (United States)

    Aslanidi, Oleg V.; Benson, Alan P.; Boyett, Mark R.; Zhang, Henggui

    2009-06-01

    Standing waves of depolarisation produced by periodic low-voltage driving eliminate propagation activity in the heart, thus providing a defibrillating effect. The phenomenon cannot be reproduced by mono- or bidomain models of cardiac tissue, where voltage perturbations decay exponentially with a space constant λ 1≈1 mm. Extension of the bidomain model taking into account effects of the external bathing medium allows simulation of the standing waves which eliminate spiral wave activity in the tissue. Mechanisms of such a defibrillating effect can be explained by the existence of an additional, unusually long space constant, λ 2≈20 mm, in the bidomain model with a bath, which emerges due to redistribution of the applied voltage by the external conductive medium.

  13. External Resistances Applied to MFC Affect Core Microbiome and Swine Manure Treatment Efficiencies.

    Science.gov (United States)

    Vilajeliu-Pons, Anna; Bañeras, Lluis; Puig, Sebastià; Molognoni, Daniele; Vilà-Rovira, Albert; Hernández-Del Amo, Elena; Balaguer, Maria D; Colprim, Jesús

    2016-01-01

    Microbial fuel cells (MFCs) can be designed to combine water treatment with concomitant electricity production. Animal manure treatment has been poorly explored using MFCs, and its implementation at full-scale primarily relies on the bacterial distribution and activity within the treatment cell. This study reports the bacterial community changes at four positions within the anode of two almost identically operated MFCs fed swine manure. Changes in the microbiome structure are described according to the MFC fluid dynamics and the application of a maximum power point tracking system (MPPT) compared to a fixed resistance system (Ref-MFC). Both external resistance and cell hydrodynamics are thought to heavily influence MFC performance. The microbiome was characterised both quantitatively (qPCR) and qualitatively (454-pyrosequencing) by targeting bacterial 16S rRNA genes. The diversity of the microbial community in the MFC biofilm was reduced and differed from the influent swine manure. The adopted electric condition (MPPT vs fixed resistance) was more relevant than the fluid dynamics in shaping the MFC microbiome. MPPT control positively affected bacterial abundance and promoted the selection of putatively exoelectrogenic bacteria in the MFC core microbiome (Sedimentibacter sp. and gammaproteobacteria). These differences in the microbiome may be responsible for the two-fold increase in power production achieved by the MPPT-MFC compared to the Ref-MFC.

  14. Transport current loss of BSCCO/Ag tape in different orientations of the external alteranting magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; ten Haken, Bernard; ten Kate, Herman H.J.

    1999-01-01

    BSCCO/Ag tapes are being developed for electrical power applications at liquid nitrogen temperatures. In these applications, conductors are exposed to an alternating magnetic field and fed simultaneously with an alternating transport current. In this contribution the influence of an external

  15. Elliptic annular Josephson tunnel junctions in an external magnetic field: the statics

    DEFF Research Database (Denmark)

    Monaco, Roberto; Granata, Carmine; Vettoliere, Antonio

    2015-01-01

    or in the perpendicular direction. We report a detailed study of both short and long elliptic annular junctions having different eccentricities. For junctions having a normalized perimeter less than one the threshold curves are derived and computed even in the case with one trapped Josephson vortex. For longer junctions...... a numerical analysis is carried out after the derivation of the appropriate perturbed sine-Gordon equation. For a given applied field we find that a number of different phase profiles exist which differ according to the number of fluxon-antifluxon pairs. We demonstrate that in samples made by specularly...... symmetric electrodes a transverse magnetic field is equivalent to an in-plane field applied in the direction of the current flow. Varying the ellipse eccentricity we reproduce all known results for linear and ring-shaped JTJs. Experimental data on high-quality Nb/Al-AlOx/Nb elliptic annular junctions...

  16. Non-regularized inversion method from light scattering applied to ferrofluid magnetization curves for magnetic size distribution analysis

    International Nuclear Information System (INIS)

    Rijssel, Jos van; Kuipers, Bonny W.M.; Erné, Ben H.

    2014-01-01

    A numerical inversion method known from the analysis of light scattering by colloidal dispersions is now applied to magnetization curves of ferrofluids. The distribution of magnetic particle sizes or dipole moments is determined without assuming that the distribution is unimodal or of a particular shape. The inversion method enforces positive number densities via a non-negative least squares procedure. It is tested successfully on experimental and simulated data for ferrofluid samples with known multimodal size distributions. The created computer program MINORIM is made available on the web. - Highlights: • A method from light scattering is applied to analyze ferrofluid magnetization curves. • A magnetic size distribution is obtained without prior assumption of its shape. • The method is tested successfully on ferrofluids with a known size distribution. • The practical limits of the method are explored with simulated data including noise. • This method is implemented in the program MINORIM, freely available online

  17. Externally-Driven Onset of Localized Magnetic Reconnection in a Magnetotail Configuration

    Science.gov (United States)

    Pritchett, P. L.; Lu, S.

    2017-12-01

    In observations of the nightside auroral arcs and ionospheric currents, the onset or breakup phase of a substorm is sharply defined in time and is highly localized in space. Attempts to understand this localization in terms of the onset of localized magnetic reconnection have generally been unsuccessful. Thus, a y-localized driving convection electric field Ey applied at the lobe boundaries spreads out before it reaches the equatorial plane and results only in 2-D reconnection. In this work, the response of a magnetotail equilibrium containing a dipole magnetic field and plasma sheet regions to the imposition of a longitudinally-limited, high-latitude driving electric field is investigated using 3-D particle-in-cell simulations. The initial response involves a reduction in the equatorial Bz field that is then followed by the development of a dawn-dusk asymmetric current sheet relative to the meridian plane of the driving field. The key feature is the presence of a dusk-side Hall electric field Ez that drives magnetic flux dawnward and thus further reduces the Bz field on the duskward side. The net result is that Bz is driven through zero in a localized region on the duskward side, leading to the onset of localized reconnection and the emergence of magnetic flux ropes. The cross-tail extent of the reconnection expands but remains limited to ˜30di, where di is the ion inertia length. The dissipation E' \\cdot J is peaked along the finite X line, with a load region (negative E' \\cdot J) forming tailward of this region. The particle energy spectra in the downtail region show shoulders for the ions in the energy range ˜3-8Eth (Eth is the initial thermal energy) and extended tails for the electrons in the range ˜10-20Eth. These results demonstrate the ability of a high-latitude disturbance that may be connected to dayside flow channels [Nishimura et al., 2014] to initiate localized magnetic reconnection in the magnetotail.

  18. Influence of an external magnetic field on damage by self-ion irradiation in Fe90Cr10 alloy

    Directory of Open Access Journals (Sweden)

    Fernando José Sánchez

    2016-12-01

    Full Text Available The effect of an external magnetic field (B=0.5 T on Fe90Cr10 specimens during Fe ion irradiation, has been investigated by means of Conversion Electron Mössbauer Spectroscopy (CEMS. The analysis has revealed significant differences in the average hyperfine magnetic field (=0.3 T between non-irradiated and irradiated samples as well as between irradiations made with B (w/ B and without B (w/o B. It is considered that these variations can be due to changes in the local environment around the probe nuclei (57Fe; where vacancies and Cr distribution play a role. The results indicate that the Cr distribution in the neighbourhood of the iron atoms could be changed by the application of an external field. This would imply that an external magnetic field may be an important parameter to take into account in predictive models for Cr behaviour in Fe–Cr alloys, and especially in fusion conditions where intense magnetic fields are required for plasma confinement.

  19. Adjustability of resonance frequency by external magnetic field and bias electric field of sandwich magnetoelectric PZT/NFO/PZT composites

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ling-Fang; Feng, Xing; Sun, Kang; Liang, Ze-Yu; Xu, Qian; Liang, Jia-Yu; Yang, Chang-Ping [Hubei University, Hubei Key Laboratory of Ferro and Piezoelectric Materials and Devices, Faculty of Physics and Electronic Science, Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Wuhan (China)

    2017-07-15

    Sandwich magnetoelectric composites of PZT/NFO/PZT (PNP) have been prepared by laminating PZT5, NiFe{sub 2}O{sub 4}, and PZT5 ceramics in turn with polyvinyl alcohol (PVA) paste. A systematic study of structural, magnetic and ferroelectric properties is undertaken. Structural studies carried out by X-ray diffraction indicate formation of cubic perovskite phase of PZT5 ceramic and cubic spinel phase of NiFe{sub 2}O{sub 4} ceramic. As increasing the content of PZT5 phase, ferroelectric loops and magnetic loops of PNP composites showed increasing remnant electric polarizations and decreasing remnant magnetic moments separately. Both external magnetic fields and bias voltages could regulate the basal radial resonance frequency of the composites, which should be originated with the transformation and coupling of the stress between the piezoelectric phase and magnetostrictive phase. Such magnetoelectric composite provides great opportunities for electrostatically tunable devices. (orig.)

  20. Magnetic resonance appearance of posterosuperior labral peel back during humeral abduction and external rotation

    International Nuclear Information System (INIS)

    Borrero, Camilo G.; Casagranda, Bethany U.; Towers, Jeffrey D.; Bradley, James P.

    2010-01-01

    To describe the magnetic resonance appearance of posterosuperior labral peel back and determine the reliability of MR in the abducted and externally rotated (ABER) position for the prospective diagnosis of arthroscopically proven cases of posterosuperior labral peel back. After approval by the institutional review board (IRB) of the University of Pittsburgh Medical Center, USA, databases of patients who underwent arthroscopy over a 2-year period for one of three clinical diagnoses [suspected type 2 superior labrum anterior to posterior (SLAP) tears, posterior instability, or multidirectional instability] were reviewed after anonymization by an honest broker. Sixty-three cases were selected by the following inclusion criteria: operative report documenting labral peel back in the ABER position, age <40 years, and preceding MR arthrogram evaluations with images in the ABER position (n = 34). Inclusion criteria for the control group differed from those for the case group insofar as the operative note documented the absence of posterosuperior labral peel back (n = 29). Cases and controls were randomized in one list and evaluated independently by two fellowship-trained musculoskeletal radiologists unaware of the surgical results and using a three-point grading system (0 = posterosuperior labrum normally positioned lateral/craniad to glenoid articular plane in ABER; 1 = posterosuperior labral tissue flush with the glenoid articular plane in ABER; 2 = posterosuperior labral tissue identified medial/caudal to glenoid articular plane in ABER). Only one image in ABER showing abnormal posterosuperior labral position was required for a grade of 1 or 2 to be assigned. Sensitivity, specificity, and positive and negative predictive value were calculated as well as the level of agreement between readers (kappa). Both readers assigned a grade of 2 to 25 of 34 patients with surgically proven labral peel back. Of the patients with surgically proven SLAP tears with peel back in ABER

  1. Magnetic resonance appearance of posterosuperior labral peel back during humeral abduction and external rotation.

    Science.gov (United States)

    Borrero, Camilo G; Casagranda, Bethany U; Towers, Jeffrey D; Bradley, James P

    2010-01-01

    To describe the magnetic resonance appearance of posterosuperior labral peel back and determine the reliability of MR in the abducted and externally rotated (ABER) position for the prospective diagnosis of arthroscopically proven cases of posterosuperior labral peel back. After approval by the institutional review board (IRB) of the University of Pittsburgh Medical Center, USA, databases of patients who underwent arthroscopy over a 2-year period for one of three clinical diagnoses [suspected type 2 superior labrum anterior to posterior (SLAP) tears, posterior instability, or multidirectional instability] were reviewed after anonymization by an honest broker. Sixty-three cases were selected by the following inclusion criteria: operative report documenting labral peel back in the ABER position, age position (n=34). Inclusion criteria for the control group differed from those for the case group insofar as the operative note documented the absence of posterosuperior labral peel back (n=29). Cases and controls were randomized in one list and evaluated independently by two fellowship-trained musculoskeletal radiologists unaware of the surgical results and using a three-point grading system (0 = posterosuperior labrum normally positioned lateral/craniad to glenoid articular plane in ABER; 1 = posterosuperior labral tissue flush with the glenoid articular plane in ABER; 2 = posterosuperior labral tissue identified medial/caudal to glenoid articular plane in ABER). Only one image in ABER showing abnormal posterosuperior labral position was required for a grade of 1 or 2 to be assigned. Sensitivity, specificity, and positive and negative predictive value were calculated as well as the level of agreement between readers (kappa). Both readers assigned a grade of 2 to 25 of 34 patients with surgically proven labral peel back. Of the patients with surgically proven SLAP tears with peel back in ABER, reader A assigned a grade of 1 to seven patients and a grade of 0 to two

  2. Mixed hyperfine interaction in amorphous Fe-Zr sputtered films in external magnetic field - a 57Fe Moessbauer study

    International Nuclear Information System (INIS)

    Fries, S.M.; Crummenauer, J.; Wagner, H.-G.; Gonser, U.; Chien, C.L.

    1986-01-01

    Conventional 57 Fe-Moessbauer spectroscopy provides only information about the magnitude of the splitting QS in the case of electric quadrupole hyperfine interaction, but not on the sign of the main component of the electric field gradient (EFG) or the asymmetry parameter which are sensitive to the local environment of the 57 Fe nuclei. This kind of information is obtained by measurements in external magnetic fields. In the case of amorphous Fe-Zr sputtered films mixed hyperfine interaction leads to a clear change in the behaviour of the Zr-rich and the Fe-rich alloys, indicating the existence of magnetic clusters in the Fe-rich samples. (Auth.)

  3. Non-destructive scanning for applied stress by the continuous magnetic Barkhausen noise method

    Science.gov (United States)

    Franco Grijalba, Freddy A.; Padovese, L. R.

    2018-01-01

    This paper reports the use of a non-destructive continuous magnetic Barkhausen noise technique to detect applied stress on steel surfaces. The stress profile generated in a sample of 1070 steel subjected to a three-point bending test is analyzed. The influence of different parameters such as pickup coil type, scanner speed, applied magnetic field and frequency band analyzed on the effectiveness of the technique is investigated. A moving smoothing window based on a second-order statistical moment is used to analyze the time signal. The findings show that the technique can be used to detect applied stress profiles.

  4. Evolution of spin correlations in SrDy2O4 in an applied magnetic field

    Science.gov (United States)

    Petrenko, O. A.; Young, O.; Brunt, D.; Balakrishnan, G.; Manuel, P.; Khalyavin, D. D.; Ritter, C.

    2017-03-01

    The development of short- and long-range magnetic order induced in a frustrated zigzag ladder compound SrDy2O4 by an applied field is studied using neutron-diffraction techniques. In zero field, SrDy2O4 lacks long-range magnetic order down to temperatures as low as 60 mK, and the observed powder-neutron-diffraction (PND) patterns are dominated by very broad diffuse scattering peaks. Single-crystal neutron diffraction reveals that the zero-field magnetic structure consists of a collection of antiferromagnetic chains running along the c axis and that there is very little correlation between the chains in the a b plane. In an applied magnetic field, the broad diffuse scattering features in PND are gradually replaced by much sharper peaks, however, the pattern remains rather complex, reflecting the highly anisotropic nature of SrDy2O4 . Single-crystal neutron diffraction shows that a moderate field applied along the b axis induces an up-up-down magnetic order associated with a 1/3 -magnetization plateau, in which magnetic correlation length in the a b plane is significantly increased, but it nevertheless remains finite. The resolution-limited k =0 peaks associated with a ferromagnetic arrangement appear in powder and single-crystal neutron-diffraction patterns in fields of 2.5 T and above.

  5. Effect of applied stress on chloride induced external stress corrosion cracking of type 304 stainless steel in air atmosphere

    International Nuclear Information System (INIS)

    Hayashibara, Hitoshi; Mayuzumi, Masami; Mizutani, Yoshihiro; Tani, Jun-ichi

    2006-01-01

    Austenitic stainless steels (SS) are widely used in various components of chemical plants, nuclear power plants, etc, because of the superior mechanical property and general corrosion resistance. However, it is also well known that austenitic stainless steels are susceptible to localized corrosion in the environments containing chloride ions, and several equipment in the plants built in coastal area has been suffering from chloride induced external stress corrosion cracking (ESCC). Hence, for the establishment of the countermeasures it is very important to clarify the factors governing ESCC process from the view points of stress, material and environmental conditions. The purpose of this study is to investigate the effect of applied stress on ESCC of type 304 stainless steel. ESCC tests were conducted on type 304 SS specimens, which were fabricated from a cold rolled plate, by a uniaxial constant load method using springs. After loading, droplets of synthetic sea water were put on the gage section of specimen and dried, and then the specimens were placed in a chamber with a constant temperature of 353 K and a relative humidity of 35%. The test specimens after the test were observed by a scanning electron microscope to measure the crack length and depth. No clear difference was found in the maximum values of the average crack propagation rate (crack depth divided by test time) among the applied stress conditions. In addition, most of ESCC were initiated from the bottom or periphery of pits under the low applied stress condition (0.5σ 0.2 ). (author)

  6. Current–voltage characteristics of hydrogen DC plasma torches with different sizes in an external axial magnetic field

    International Nuclear Information System (INIS)

    Ma Jie; Wen Guang-Dong; Su Bao-Gen; Yang Yi-Wen; Ren Qi-Long

    2015-01-01

    Current–voltage (I–V) characteristics of hydrogen DC plasma torches with different sizes in an external axial magnetic field under atmospheric pressure are reported. Three anodes with different diameters are adopted in a 50-kW torch: 25 mm, 30 mm, and 35 mm, respectively. Two different diameters of anodes, that is, 100 mm and 130 mm, are adopted in a 1-MW plasma torch. The arc voltage shows a negative trend with the increase of arc current under the operating regimes. On the contrary, arc voltage shows a positive trend as the flow rate of carrier gas increases, and a similar trend is found with increasing the external magnetic flux density. A similarity formula is constructed to correlate the experimental data of the torches mentioned above. Linear fitting shows that the Pearson correlation coefficient is 0.9958. (paper)

  7. Improved biological wastewater treatment and sludge characteristics by applying magnetic field to aerobic granules

    Directory of Open Access Journals (Sweden)

    Yong-Qiang Liu

    2016-10-01

    Full Text Available Permanent magnets with non-uniform magnetic field and an electromagnet with 3–5 mT uniform magnetic field were applied to investigate their effects on both aerobic granulation and COD and ammonium removal in reactors with less than 7% coverage of magnetic field. It was found that both types of magnets had little influence on the granulation speed and the settling ability of granular sludge at the steady state. However, the maximum specific COD degradation rate and the maximum specific NH4+-N removal rate were increased by 45–54% and 30–50%, respectively, in the magnetic fields. Mean effluent COD with the electromagnet and the permanent magnet field, respectively, at the steady state, was 28 mg l−1 and 6 mg l−1, respectively, lower than the control at a statistical significance level of alpha = 0.05. No statistically significant increase in NH4+-N removal was observed at the steady state probably due to almost complete NH4+-N removal before the end of the cycle. In addition, it was found that extracellular polymeric substances in granular sludge with electromagnet were 77% more while soluble microbial products were much less compared with the control, suggesting a positively changed metabolism of granular sludge at steady state. The results in this study indicated that low-intensity magnetic field has a great potential to be applied in granular sludge for an improved wastewater treatment.

  8. Stability properties of a toroidal z-pinch in an external magnetic multipole field

    International Nuclear Information System (INIS)

    Eriksson, H.G.

    1987-01-01

    MHD stability of m=1, axisymmetric, external modes of a toroidal z-pinch immersed in an external multipole field (Extrap configuration) is studied. The description includes the effects of a weak toroidicity, a non-circular plasma cross-section and the influence of induced currents in the external conductors. It is found that the non-circularity of the plasma cross-section always has a destabilizing effect but that the m=1 mode can be stabilized by the external feedback if the non-circularity is small. (author)

  9. Effect of external magnetic field and variable dust electrical charge on the shape and propagation of solitons in the two nonthermal ions dusty plasma

    International Nuclear Information System (INIS)

    Ghalambor Dezfuly, S.; Dorranian, D.

    2012-01-01

    In this manuscript, the effect of dust electrical charge, nonthermal ions, and external magnetic field on the shape and propagation of solitons in dusty plasma with two nonthermal ions is studied theoretically. Using the reductive perturbation theory, the Zakharov-Kuznetsov equation for propagation of dust acoustic waves is extracted. Results show that external magnetic field does not affect the amplitude of solitary wave but width of solitons are effectively depend on the magnitude of external magnetic field. With increasing the charge of dust particles the amplitude of solution will increase while their width will decrease. Increasing the nonthermal ions lead to opposite effect.

  10. Local magnetic moments in dilute Cr-Nb alloys: the effects of applied magnetic field and Nb concentration

    International Nuclear Information System (INIS)

    Souza, P E N de; Oliveira, L M de; Ortiz, W A; Camargo, P C de; Oliveira, A J A de

    2005-01-01

    In this work we present magnetic susceptibility results for Cr-x at.% Nb alloys (x = 0.2, 0.6, 0.7, 1.4, and 2.0), showing that a local short-range order spin-density wave (L-SDW) appears at a characteristic temperature (T loc ) above the Neel temperature. The evidence for L-SDW is based on a Curie-Weiss-like behaviour, which is suppressed when large magnetic fields are applied or for alloys with Nb concentration above x = 2.0 at.%

  11. Technique for recovering rare-earth metals from spent sintered Nd-Fe-B magnets without external heating

    Directory of Open Access Journals (Sweden)

    Ryo Sasai

    2016-06-01

    Full Text Available To selectively recover rare-earth metals with higher purity from spent sintered Nd-Fe-B magnets without external heating, we investigated the mechano-chemical treatment of spent sintered Nd-Fe-B magnet powder with a reaction solution of HCl and (COOH2 at room temperature. The results of various experiments showed that the mechano-chemical treatment with HCl and (COOH2 is very effective for recovering the rare-earth metals contained in spent sintered Nd-Fe-B magnet powder; the recovery rate and purity of the rare-earth metals were 95.3 and 95.0 mass%, respectively, under optimal conditions ([HCl] = 0.2 mol/dm3 and [(COOH2] = 0.25 mol/dm3.

  12. Effect of interdiffusion and external magnetic field on electronic states and light absorption in Gaussian-shaped double quantum ring

    Science.gov (United States)

    Aziz-Aghchegala, V. L.; Mughnetsyan, V. N.; Kirakosyan, A. A.

    2018-02-01

    The effect of interdiffusion and magnetic field on confined states of electron and heavy hole as well as on interband absorption spectrum in a Ga1-xAlxAs/GaAs Gaussian-shaped double quantum ring are investigated. It is shown that both interdiffusion and magnetic field lead to the change of the charge carriers' quantum states arrangement by their energies. The oscillating behavior of the electron ground state energy as a function of magnetic field induction gradually disappears with the increase of diffusion parameter due to the enhanced tunneling of electron to the central region of the ring. For the heavy hole the ground state energy oscillations are not observable in the region of the values of magnetic field induction B = 0 - 10 T . For considered transitions both the magnetic field and the interdiffusion lead to a blue-shift of the absorption spectrum and to decreasing of the absorption intensity. The obtained results indicate on the opportunity of purposeful manipulation of energy states and absorption spectrum of a Gaussian-shaped double quantum ring by means of the post growth annealing and the external magnetic field.

  13. Torque Ripple Suppression in an External-Meshed Magnetic Gear Train

    OpenAIRE

    Yi-Chang Wu; Wan-Tsun Tseng; Yueh-Tung Chen

    2013-01-01

    Magnetic gear trains transmit torque through noncontact magnetic couplings rather than conjugate gear teeth; they have the unique advantages of reduced maintenance and improved reliability, inherent overload protection, high efficiency, precise peak torque transmission, and tolerance for misalignment. Smooth and steadily transmitted torque is an important characteristic for a magnetic gear train. It is necessary for the reduction of possible mechanical vibration, position inaccuracy, and acou...

  14. Dependence of Fe/Cr superlattice magnetoresistance on orientation of external magnetic field

    International Nuclear Information System (INIS)

    Ustinov, V.V.; Romashev, L.N.; Minin, V.I.; Semerikov, A.V.; Del', A.R.

    1995-01-01

    The paper presents the results of investigations into giant magnetoresistance of [Fe/Cr] 30 /MgO superlattices obtained using molecular-beam epitaxy under various orientations of magnetic field relatively to the layers of superlattice and to the direction of current flow. Theory of orientation dependence of superlattice magnetoresistance enabling to describe satisfactorily behaviour of magnetoresistance at arbitrary direction of magnetic field on the ground of results of magnetoresistance measurements in magnetic field parallel and perpendicular to plane of layers, is elaborated. It is pointed out that it is possible to obtain field dependence of superlattice magnetization on the ground of measurement results. 9 refs., 6 figs

  15. Magnetic field on fouling control of ultrafiltration membranes applied in treatment of a synthetic textile effluent.

    Science.gov (United States)

    Carlesso, Franciele; Zin, Guilherme; de Souza, Selene M A G U; Luccio, Marco Di; de Souza, Antonio A U; Oliveira, J Vladimir

    2016-01-01

    Membrane performance is decreased by fouling, reducing permeate flux and membrane lifespan. This paper assesses ultrafiltration of a model textile effluent assisted by permanent magnetic field as an alternative to improve the water permeability recovery. Ultrafiltration was performed in a tangential module and model solutions, composed of carboxymethylcellulose (CMC) and sodium sulphate (Na2SO4). The feed was permeated through 30 kDa polysulphone membrane with and without the presence of a permanent magnetic field of 0.41 T, perpendicular to the membrane surface. Magnetic induction (MI) of feed solution was also investigated by recirculation of the feed stream through the magnetic field for 3 h. The increase in feed concentration did not affect permeate flux, while the presence of salt resulted in a severe flux decline. Effective water permeability recovery was obtained when the magnetic field was applied in the ultrafiltration process, although the MI of the CMC and Na2SO4 solutions also caused some enhancement in permeability recovery. Scanning electron microscopy images showed differences between the assays done with and without the presence of magnetic field. The magnetic field application in ultrafiltration of CMC and Na2SO4 solutions has proved to be an attractive alternative for improving the permeability recovery.

  16. Micron and sub-micron feature replication of amorphous polymers at elevated mold temperature without externally applied pressure

    International Nuclear Information System (INIS)

    Mosaddegh, Peiman; Angstadt, David C

    2008-01-01

    The focus of this study is on the ability of amorphous polymers to replicate micron and sub-micron features when molded at an elevated mold temperature without externally applied pressure. Molding was performed using three different types of amorphous polymers: cyclo-olefin copolymer (COC), polystyrene (PS) and poly (methyl methacrylate) (PMMA) on a silicon mold containing surface features as small as 700 nm in depth and aspect ratios ranging from 5 to 0.02. In this study, processing temperatures were selected in order to match the viscosity for all polymers used. Polymer viscosity was characterized via cone and plate rheometry and wettability was characterized via contact angle analysis to quantify interfacial effects. Feature replication was assessed using scanning electron microscopy (SEM) and atomic force microscopy (AFM) to compare the molded feature depth ratio. It was observed that for the features with an aspect ratio (depth/width) bigger than 2 the depth ratio of the molded parts decreases. PS shows the best replication because of high wettability behavior. PMMA shows the intermediate replication because of dipole–dipole interaction and its lower diffusion coefficient than PS. COC has the worse replication especially in low aspect ratio because of sticking to the silicon oxide layer. PS has the best surface roughness among all polymers

  17. Control of motion of tibial fractures with use of a functional brace or an external fixator. A study of cadavera with use of a magnetic motion sensor.

    Science.gov (United States)

    McKellop, H; Hoffmann, R; Sarmiento, A; Ebramzadeh, E

    1993-07-01

    A computer-linked magnetic motion transducer was used to monitor and record the six components of motion of the bone fragments in eight cadaveric tibiae in which a simulated, oblique fracture of the middle of the shaft had been stabilized with a functional brace. The limbs were mounted in a servo-hydraulic testing frame, and a cyclic load of 150 newtons was applied along the axis of the tibia. Motion sensors, attached to each side of the fracture, measured and displayed the values of the three translations (axial, anterior-posterior, and medial-lateral), the axial rotation, and the two angulations (anterior-posterior and varus-valgus) as they occurred. Although only an axial load was applied, the off-axis motions were comparable in magnitude with the motion along the axis. The elastic (recoverable) translations of the fragments ranged from 0.5 to 1.9 millimeters, about four to ten times larger than the corresponding motions that were recorded in an earlier study of such fractures that had been stabilized with two types of external fixators. The recoverable rotation and angulations of the fragments of the limbs in the functional brace ranged from 0.7 to 1.2 degrees, about ten times those recorded when the external fixators were used.

  18. rf breakdown with external magnetic fields in 201 and 805 MHz cavities

    Directory of Open Access Journals (Sweden)

    R. B. Palmer

    2009-03-01

    Full Text Available Neutrino factory and muon collider cooling lattices require both high gradient rf cavities and strong focusing solenoids. Experiments have shown that there may be serious problems operating rf in the required magnetic fields. Experimental observations using vacuum rf cavities in magnetic fields are discussed, current published models of breakdown with and without magnetic fields are briefly summarized, and some of their predictions compared with observations. A new theory of magnetic field dependent breakdown is presented. It is proposed that electrons emitted by field emission on asperities on one side of a cavity are focused by the magnetic field to the other side where they induce mechanical fatigue leading to cavity surface damage in small spots. Metal is then electrostatically drawn from the molten spots, becomes vaporized and ionized by field emission from the remaining damage, and causes breakdown. The theory is fitted to existing 805 MHz data and predictions are made for performance at 201 MHz. The model predicts breakdown gradients significantly below those specified for either the International Scoping Study neutrino factory or a muon collider. Possible solutions to these problems are discussed, including designs for magnetically insulated rf in which the cavity walls are designed to be parallel to chosen magnetic field contour lines and consequently damage from field emission is expected to be suppressed. An experimental program that could study these problems and their possible solution is outlined. We also mention the use of high pressure gas as an alternative possible solution.

  19. A β-Ta system for current induced magnetic switching in the absence of external magnetic field

    Science.gov (United States)

    Chen, Wenzhe; Qian, Lijuan; Xiao, Gang

    2018-05-01

    Magnetic switching via Giant Spin Hall Effect (GSHE) has received great interest for its role in developing future spintronics logic or memory devices. In this work, a new material system (i.e. a transition metal sandwiched between two ferromagnetic layers) with interlayer exchange coupling is introduced to realize the deterministic field-free perpendicular magnetic switching. This system uses β-Ta, as the GSHE agent to generate a spin current and as the interlayer exchange coupling medium to generate an internal field. The critical switching current density at zero field is on the order of 106 A/cm2 due to the large spin Hall angle of β-Ta. The internal field, along with switching efficiency, depends strongly on the orthogonal magnetization states of two ferromagnetic coupling layers in this system.

  20. Optical bistability and multistability driven by external magnetic field in a dielectric slab doped with nanodiamond nitrogen vacancy centres

    Science.gov (United States)

    Nasehi, R.; Norouzi, F.

    2016-08-01

    The theoretical investigation of controlling the optical bistability (OB) and optical multistability (OM) in a dielectric medium doped with nanodiamond nitrogen vacancy centres under optical excitation are reported. The shape of the OB curve from dielectric slab can be tuned by changing the external magnetic field and polarization of the control beam. The effect of the intensity of the control laser field and the frequency detuning of probe laser field on the OB and OM behaviour are also discussed in this paper. The results obtained can be used for realizing an all-optical bistable switching or development of nanoelectronic devices.

  1. Effect of an external magnetic field on polytypism of CdI2 crystals grown from solutions

    International Nuclear Information System (INIS)

    Palosz, B.; Przedmojski, J.

    1982-01-01

    The effect of growth conditions on the polytypic structure of crystals of CdI 2 was analyzed for crystallization from solutions. Three solvents were used: H 2 O, 3 H 2 O + 1 C 2 H 5 OH and 1 H 2 O + 1 C 2 H 5 OH. Crystals were grown at two temperatures: 5 and 25 0 C with low and high growth rates; an external magnetic field of about 0.25 tesla was used. The effect of the above three parameters on the formation of the basic polytypes 2H and 4H and on the ordering of faults in disordered structures and in polytype cells was studied by X-ray analysis of crystal surfaces. Some distinct relations between the polytypic structure of crystals of CdI 2 and the magnetic field were found. (author)

  2. Approximate energies and thermal properties of a position-dependent mass charged particle under external magnetic fields

    International Nuclear Information System (INIS)

    Eshghi, M; Mehraban, H; Ikhdair, S M

    2017-01-01

    We solve the Schrödinger equation with a position-dependent mass (PDM) charged particle interacted via the superposition of the Morse-plus-Coulomb potentials and is under the influence of external magnetic and Aharonov–Bohm (AB) flux fields. The nonrelativistic bound state energies together with their wave functions are calculated for two spatially-dependent mass distribution functions. We also study the thermal quantities of such a system. Further, the canonical formalism is used to compute various thermodynamic variables for second choosing mass by using the Gibbs formalism. We give plots for energy states as a function of various physical parameters. The behavior of the internal energy, specific heat, and entropy as functions of temperature and mass density parameter in the inverse-square mass case for different values of magnetic field are shown. (paper)

  3. Coupling of an applied field magnetically insulated ion diode to a high power magnetically insulated transmission line system

    International Nuclear Information System (INIS)

    Maenchen, J.E.

    1983-01-01

    The coupling of energy from a high power pulsed accelerator through a long triplate magnetically insulated transmission line (MITL) in vacuum to an annular applied magnetic field insulated extraction ion diode is examined. The narrow power transport window and the wave front erosion of the MITL set stringent impedance history conditions on the diode load. A new ion diode design developed to satisfy these criteria with marginal electron insulation is presented. The LION accelerator is used to provide a positive polarity 1.5 MV, 350 kA, 40 ns FWHM pulse with a 30 kA/ns current rate from a triplate MITL source. A transition converts the triplate into a cylindrical cross section which flares into the ion diode load. Extensive current and voltage measurements performed along this structure and on the extracted ion beam provide conclusive evidence that the self insulation condition of the MITL is maintained in the transition by current loss alone. The ion diode utilizes a radial magnetic field between a grounded cathode annular emission tip and a disk anode. A 50 cm 2 dielectric/metal anode area serves as the ion plasma source subject to direct electron bombardment from the opposing cathode tip under marginal magnetic insulation conditions. The ions extracted cross the radial magnetic field and exit the diode volume as an annular cross section beam of peak current about 100 kA. The diode current gradually converts from the initial electron flow to nearly 100% ion current after 30 ns, coupling 60% of the diode energy into ions

  4. RF power absorption by plasma of low pressure low power inductive discharge located in the external magnetic field

    Science.gov (United States)

    Kralkina, E. A.; Rukhadze, A. A.; Nekliudova, P. A.; Pavlov, V. B.; Petrov, A. K.; Vavilin, K. V.

    2018-03-01

    Present paper is aimed to reveal experimentally and theoretically the influence of magnetic field strength, antenna shape, pressure, operating frequency and geometrical size of plasma sources on the ability of plasma to absorb the RF power characterized by the equivalent plasma resistance for the case of low pressure RF inductive discharge located in the external magnetic field. The distinguishing feature of the present paper is the consideration of the antennas that generate not only current but charge on the external surface of plasma sources. It is shown that in the limited plasma source two linked waves can be excited. In case of antennas generating only azimuthal current the waves can be attributed as helicon and TG waves. In the case of an antenna with the longitudinal current there is a surface charge on the side surface of the plasma source, which gives rise to a significant increase of the longitudinal and radial components of the RF electric field as compared with the case of the azimuthal antenna current.

  5. APPLICATION OF MULTILAYER FILM CONFIGURATION TO PROTECT PHOTOMULTIPLIER AGAINST EXTERNAL STATIC MAGNETIC FIELDS

    Directory of Open Access Journals (Sweden)

    A. G. Batische

    2012-01-01

    Full Text Available The effectiveness of the screening constant magnetic field is multi-layered film screens system of NiFe/Cu, formed on the cylindrical housing of photomultiplier tubes, and compared with screen-based steel material – brand 80NHS permalloy. It is shown that the most effective is the screen on the basis of the multilayered film screens, which provide shielding effectiveness value 8–10 in magnetic fields with induction of 0,1–1 mT, and 80–100 – in magnetic fields with induction of 2–4 mT , which is 4–5 times higher than for the screen of the material 80NHS.

  6. Currency crisis and external fragility: a Minskyan interpretation applied to the Brazilian economy between 1999 and 2013

    Directory of Open Access Journals (Sweden)

    Victor Hugo Rocha Sarto

    2016-12-01

    Full Text Available This work has two goals. The first one is to develop an interpretation for open economies founded on Minsky’s financial fragility hypothesis about the process of a currency crisis and its determinants. The deterioration of an economy’s external financial structure is identified as the reason for the increase of its crisis susceptibility. With this approach, we create external fragility indexes intending to measure an economy’s crisis susceptibility. Our second objective is to evaluate the Brazilian external fragility between 1999 and 2013 using the index and the interpretation previously developed. The results suggest that Brazilian’s external fragility suffered a gradual and significant decrease and tends to follow stable trend in the coming years.

  7. Electron-Spin Precession in Dependence of the Orientation of the External Magnetic Field.

    Science.gov (United States)

    Miah, M Idrish

    2009-03-13

    Electron-spin dynamics in semiconductor-based heterostructures has been investigated in oblique magnetic fields. Spins are generated optically by a circularly polarized light, and the dynamics of spins in dependence of the orientation (theta) of the magnetic field are studied. The electron-spin precession frequency, polarization amplitude, and decay rate as a function of theta are obtained and the reasons for their dependences are discussed. From the measured data, the values of the longitudinal and transverse components of the electron g-factor are estimated and are found to be in good agreement with those obtained in earlier investigations. The possible mechanisms responsible for the observed effects are also discussed.

  8. Study of transport phenomena in laser-driven, non- equilibrium plasmas in the presence of external magnetic fields

    Science.gov (United States)

    Kemp, G. Elijah; Mariscal, D. A.; Williams, G. J.; Blue, B. E.; Colvin, J. D.; Fears, T. M.; Kerr, S. M.; May, M. J.; Moody, J. D.; Strozzi, D. J.; Lefevre, H. J.; Klein, S. R.; Kuranz, C. C.; Manuel, M. J.-E.; Gautier, D. C.; Montgomery, D. S.

    2017-10-01

    We present experimental and simulation results from a study of thermal transport inhibition in laser-driven, mid-Z, non-equilibrium plasmas in the presence external magnetic fields. The experiments were performed at the Jupiter Laser Facility at LLNL, where x-ray spectroscopy, proton radiography, and Brillouin backscatter data were simultaneously acquired from sub-critical-density, Ti-doped silica aerogel foams driven by a 2 ω laser at 5 ×1014 W /cm2 . External B-field strengths up to 20 T (aligned antiparallel to the laser propagation axis) were provided by a capacitor-bank-driven Helmholtz coil. Pre-shot simulations with Hydra, a radiation-magnetohydrodyanmics code, showed increasing electron plasma temperature with increasing B-field strength - the result of thermal transport inhibition perpendicular to the B-field. The influence of this thermal transport inhibition on the experimental observables as a function of external field strength and target density will be shown and compared with simulations. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344 and funded by LDRD project 17-ERD-027.

  9. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    International Nuclear Information System (INIS)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V.

    2009-01-01

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  10. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Antonio C. Westphalen

    2009-04-01

    Full Text Available PURPOSE: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. MATERIAL AND METHODS: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher’s exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25 and those imaged more than 3 years after therapy (n = 34. Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. RESULTS: Thirty-four of 59 patients (58% had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59 for reader 1 and 71% for reader 2 (42/59. For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2. CONCLUSION: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy.

  11. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V. [University of California San Francisco, San Francisco, CA (United States). Dept. of Radiology. Abdominal Imaging Section], e-mail: antonio.westphalen@radiology.ucsf.edu

    2009-01-15

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  12. Partial phase transition and quantum effects in helimagnetic films under an applied magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    El Hog, Sahbi, E-mail: sahbi.el-hog@u-cergy.fr; Diep, H.T., E-mail: diep@u-cergy.fr

    2017-05-01

    We study the phase transition in a helimagnetic film with Heisenberg spins under an applied magnetic field in the c direction perpendicular to the film. The helical structure is due to the antiferromagnetic interaction between next-nearest neighbors in the c direction. Helimagnetic films in zero field are known to have a strong modification of the in-plane helical angle near the film surfaces. We show that spins react to a moderate applied magnetic field by creating a particular spin configuration along the c axis. With increasing temperature (T), using Monte Carlo simulations we show that the system undergoes a phase transition triggered by the destruction of the ordering of a number of layers. This partial phase transition is shown to be intimately related to the ground-state spin structure. We show why some layers undergo a phase transition while others do not. The Green's function method for non collinear magnets is also carried out to investigate effects of quantum fluctuations. Non-uniform zero-point spin contractions and a crossover of layer magnetizations at low T are shown and discussed. - Highlights: • Monte Carlo simulations were carried out to study a helimagnetic film in a field. • Partial phase transition is found in some layers of the film. • Mechanism leading to the partial disordering is analyzed using the ground state symmetry. • Quantum fluctuations at surface are calculated using the Green's function.

  13. Valence and Magnetic Transitions in YbMn2Ge2-Applied Pressure

    International Nuclear Information System (INIS)

    Hofmann, M.; Link, P.; Campbell, S.J.; Goncharenko, I.

    2005-01-01

    Full text: Rare-earth intermetallic compounds containing ytterbium exhibit a wide range of interesting and unusual physical and magnetic properties. This occurs mainly as a result of their mixed valence states (II/III) or changes from one valence state to the other. We have recently determined the magnetic structures of tetragonal YbMn 2 Ge 2 (I4/mmm) by powder neutron diffraction experiments and demonstrated that YbMn 2 Ge 2 has a planar antiferromagnetic structure below T N1 ∼ 510 K with a canted antiferromagnetic structure below T N2 ∼ 185 K. As applied pressure favours changes in the valence character of intermediate valence systems and correspondingly influences the magnetic behaviour, we have investigated the effects of applied pressure on YbMn 2 Ge 2 . Analyses of our in situ neutron diffraction experiments (T=1.5-300 K; p=0-2.7 GPa), reveal a distinct change in magnetic structure and a sharp drop in the a-lattice parameter above ∼ 1.4 GPa with the changes associated with a valence transition. A full account of these effects will be discussed in relation to our current photoelectron spectroscopy measurements of YbMn 2 Ge 2 . (authors)

  14. Measuring transport current loss of BSCCO/Ag tapes exposed to external AC magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; ten Haken, Bernard; ten Kate, Herman H.J.

    1998-01-01

    BSCCO/Ag tape superconductors are developed for electrical power applications at liquid nitrogen temperatures. In these applications, e.g., superconducting transformers and power cables, an AC transport current and an AC magnetic field are present at the same time. A set-up to measure the influence

  15. Longitudinal wave function control in single quantum dots with an applied magnetic field.

    Science.gov (United States)

    Cao, Shuo; Tang, Jing; Gao, Yunan; Sun, Yue; Qiu, Kangsheng; Zhao, Yanhui; He, Min; Shi, Jin-An; Gu, Lin; Williams, David A; Sheng, Weidong; Jin, Kuijuan; Xu, Xiulai

    2015-01-27

    Controlling single-particle wave functions in single semiconductor quantum dots is in demand to implement solid-state quantum information processing and spintronics. Normally, particle wave functions can be tuned transversely by an perpendicular magnetic field. We report a longitudinal wave function control in single quantum dots with a magnetic field. For a pure InAs quantum dot with a shape of pyramid or truncated pyramid, the hole wave function always occupies the base because of the less confinement at base, which induces a permanent dipole oriented from base to apex. With applying magnetic field along the base-apex direction, the hole wave function shrinks in the base plane. Because of the linear changing of the confinement for hole wave function from base to apex, the center of effective mass moves up during shrinking process. Due to the uniform confine potential for electrons, the center of effective mass of electrons does not move much, which results in a permanent dipole moment change and an inverted electron-hole alignment along the magnetic field direction. Manipulating the wave function longitudinally not only provides an alternative way to control the charge distribution with magnetic field but also a new method to tune electron-hole interaction in single quantum dots.

  16. Nuclear magnetic resonance applied to the study of polymeric nano composites

    International Nuclear Information System (INIS)

    Tavares, Maria Ines Bruno

    2011-01-01

    Polymers and nanoparticles based nano composites were prepared by intercalation by solution. The obtained nano composites were characterized mainly by the nuclear magnetic spectroscopy (NMR), applying the analysis of carbon-13 (polymeric matrix), silicon-29 (nanoparticle), and by determination of spin-lattice relaxation of the hydrogen nucleus (T 1 H) (polymeric matrix). The NMR have presented a promising technique in the characterization of the nano charge dispersion in the studied polymeric matrixes.

  17. Multilayered Magnetic Gelatin Membrane Scaffolds

    Science.gov (United States)

    Samal, Sangram K.; Goranov, Vitaly; Dash, Mamoni; Russo, Alessandro; Shelyakova, Tatiana; Graziosi, Patrizio; Lungaro, Lisa; Riminucci, Alberto; Uhlarz, Marc; Bañobre-López, Manuel; Rivas, Jose; Herrmannsdörfer, Thomas; Rajadas, Jayakumar; De Smedt, Stefaan; Braeckmans, Kevin; Kaplan, David L.; Dediu, V. Alek

    2016-01-01

    A versatile approach for the design and fabrication of multilayer magnetic scaffolds with tunable magnetic gradients is described. Multilayer magnetic gelatin membrane scaffolds with intrinsic magnetic gradients were designed to encapsulate magnetized bioagents under an externally applied magnetic field for use in magnetic-field-assisted tissue engineering. The temperature of the individual membranes increased up to 43.7 °C under an applied oscillating magnetic field for 70 s by magnetic hyperthermia, enabling the possibility of inducing a thermal gradient inside the final 3D multilayer magnetic scaffolds. On the basis of finite element method simulations, magnetic gelatin membranes with different concentrations of magnetic nanoparticles were assembled into 3D multilayered scaffolds. A magnetic-gradient-controlled distribution of magnetically labeled stem cells was demonstrated in vitro. This magnetic biomaterial–magnetic cell strategy can be expanded to a number of different magnetic biomaterials for various tissue engineering applications. PMID:26451743

  18. Enhancing Ignition Probability and Fusion Yield in NIF Indirect Drive Targets with Applied Magnetic Fields

    Science.gov (United States)

    Perkins, L. John; Logan, B. Grant; Ho, Darwin; Zimmerman, George; Rhodes, Mark; Blackfield, Donald; Hawkins, Steven

    2017-10-01

    Imposed magnetic fields of tens of Tesla that increase to greater than 10 kT (100 MGauss) under capsule compression may relax conditions for ignition and propagating burn in indirect-drive ICF targets. This may allow attainment of ignition, or at least significant fusion energy yields, in presently-performing ICF targets on the National Ignition Facility that today are sub-marginal for thermonuclear burn through adverse hydrodynamic conditions at stagnation. Results of detailed 2D radiation-hydrodynamic-burn simulations applied to NIF capsule implosions with low-mode shape perturbations and residual kinetic energy loss indicate that such compressed fields may increase the probability for ignition through range reduction of fusion alpha particles, suppression of electron heat conduction and stabilization of higher-mode RT instabilities. Optimum initial applied fields are around 50 T. Off-line testing has been performed of a hohlraum coil and pulsed power supply that could be integrated on NIF; axial fields of 58T were obtained. Given the full plasma structure at capsule stagnation may be governed by 3-D resistive MHD, the formation of closed magnetic field lines might further augment ignition prospects. Experiments are now required to assess the potential of applied magnetic fields to NIF ICF ignition and burn. Work performed under auspices of U.S. DOE by LLNL under Contract DE-AC52-07NA27344.

  19. Novel Application of Time-Spatial Labeling Inversion Pulse Magnetic Resonance Imaging for Diagnosis of External Hydrocephalus.

    Science.gov (United States)

    Nakae, Shunsuke; Murayama, Kazuhiro; Adachi, Kazuhide; Kumai, Tadashi; Abe, Masato; Hirose, Yuichi

    2018-01-01

    Although a subdural fluid collection frequently is observed, diagnostic methods that differentiate between the subdural collection caused by external hydrocephalus and that caused by subdural hygroma have not been established. Here, we report a case of external hydrocephalus caused by Gliadel-induced eosinophilic meningitis that has been previously reported in only 1 case and can be diagnosed by time-spatial labeling inversion pulse magnetic resonance imaging (time-SLIP MRI). A tumor located in the left temporal was detected incidentally in an 81-year-old man by examination of a head injury. The tumor was surgically resected and diagnosed as a high-grade glioma during the surgery; Gliadel wafers subsequently were implanted. Three weeks after the resection, the patient showed disturbed consciousness, and computed tomography revealed a subdural fluid collection. The out-flow of cerebrospinal through the resection cavity was detected by time-SLIP MRI. Cerebrospinal tests indicated high white blood cell counts and high protein levels, with more than 90% of the white blood cell count comprising eosinophils. Therefore, we suspected that the subdural fluid collection was caused by external hydrocephalus because of Gliadel-induced eosinophilic meningitis. We surgically removed the Gliadel wafers and subsequently performed a surgery to insert a ventriculoperitoneal shunt. Histologic examination indicated eosinophilic accumulation around the Gliadel wafers. The patient's symptoms improved after the insertion of a ventriculoperitoneal shunt. In the present case, time-SLIP MRI was a useful and noninvasive method for diagnosing external hydrocephalus which was caused by eosinophilic meningitis because of Gliadel-induced eosinophilic meningitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Proposal of a methodology to be applied for the characterization of external exposure risk of employees in nuclear medicine services

    International Nuclear Information System (INIS)

    Simoes, Rafael Figueiredo Pohlmann

    2010-01-01

    Nuclear medicine procedure requires the administration of radioactive material by injection, ingestion or inhalation. After incorporation, the patient becomes a mobile source of radiation and, after their examination; they can irradiate everyone on their way out of the Nuclear Medicine Service (NMS). A group of workers in this path is considered a critical group, but there are no conviction on this classification, because there are not measurements available. Thus, workers claiming for occupationally exposed individual's (OEI) rights are common. Employers are always in a complex situation, because if they decided to undertake the individual external monitoring of the critical working groups, the Court considers all as OEI and employers are taxed. On the other hand, if they do not provide monitoring, it is impossible to prove that these workers were not exposed to effective doses higher than individual annual public's limit and they lose the actions, too. This work proposes a methodology to evaluate, using TLD environmental monitors, air kerma rate at critical staff points in a NMS. This method provides relevant information about critical groups' exposure. From these results, the clinic or hospital may prove technically, without individual monitoring of employees, the classification of areas and can estimate the maximum flow of patients in the free areas which guarantees exposures below the public individual dose limit. This methodology has been applied successfully to a private clinic in Rio de Janeiro, which operates a NMS. The only critical group that received exposure statistically different from clinic background radiation was that on the antechamber of the NMS. This is a site that should be characterized as a supervised area and the group of workers in this environment as OEI, as the estimated extrapolated annual effective dose in this position was 1.2 +- 0.7 mSv/year, above the public annual limit (1,0 mSv/year). Normalizing by the number of patients, it can

  1. Magnetically applied pressure-shear : a new technique for direct strength measurement at high pressure (final report for LDRD project 117856).

    Energy Technology Data Exchange (ETDEWEB)

    Lamppa, Derek C.; Haill, Thomas A.; Alexander, C. Scott; Asay, James Russell

    2010-09-01

    A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined.

  2. Chiral and parity symmetry breaking for planar fermions: Effects of a heat bath and uniform external magnetic field

    International Nuclear Information System (INIS)

    Ayala, Alejandro; Bashir, Adnan; Gutierrez, Enif; Raya, Alfredo; Sanchez, Angel

    2010-01-01

    We study chiral symmetry breaking for relativistic fermions, described by a parity-violating Lagrangian in 2+1-dimensions, in the presence of a heat bath and a uniform external magnetic field. Working within their four-component formalism allows for the inclusion of both parity-even and -odd mass terms. Therefore, we can define two types of fermion antifermion condensates. For a given value of the magnetic field, there exist two different critical temperatures which would render one of these condensates identically zero, while the other would survive. Our analysis is completely general: it requires no particular simplifying hierarchy among the energy scales involved, namely, bare masses, field strength, and temperature. However, we do reproduce some earlier results, obtained or anticipated in literature, corresponding to special kinematical regimes for the parity conserving case. Relating the chiral condensate to the one-loop effective Lagrangian, we also obtain the magnetization and the pair production rate for different fermion species in a uniform electric field through the replacement B→-iE.

  3. Electron-Spin Precession in Dependence of the Orientation of the External Magnetic Field

    Directory of Open Access Journals (Sweden)

    Miah M

    2009-01-01

    Full Text Available Abstract Electron-spin dynamics in semiconductor-based heterostructures has been investigated in oblique magnetic fields. Spins are generated optically by a circularly polarized light, and the dynamics of spins in dependence of the orientation (θ of the magnetic field are studied. The electron-spin precession frequency, polarization amplitude, and decay rate as a function ofθare obtained and the reasons for their dependences are discussed. From the measured data, the values of the longitudinal and transverse components of the electrong-factor are estimated and are found to be in good agreement with those obtained in earlier investigations. The possible mechanisms responsible for the observed effects are also discussed.

  4. Kinetic Ising model in a time-dependent oscillating external magnetic field: effective-field theory

    International Nuclear Information System (INIS)

    Deviren, Bayram; Canko, Osman; Keskin, Mustafa

    2010-01-01

    Recently, Shi et al. [2008 Phys. Lett. A 372 5922] have studied the dynamical response of the kinetic Ising model in the presence of a sinusoidal oscillating field and presented the dynamic phase diagrams by using an effective-field theory (EFT) and a mean-field theory (MFT). The MFT results are in conflict with those of the earlier work of Tomé and de Oliveira, [1990 Phys. Rev. A 41 4251]. We calculate the dynamic phase diagrams and find that our results are similar to those of the earlier work of Tomé and de Oliveira; hence the dynamic phase diagrams calculated by Shi et al. are incomplete within both theories, except the low values of frequencies for the MFT calculation. We also investigate the influence of external field frequency (ω) and static external field amplitude (h 0 ) for both MFT and EFT calculations. We find that the behaviour of the system strongly depends on the values of ω and h 0 . (general)

  5. Analysis of domain wall dynamics based on skewness of magnetic Barkhausen noise for applied stress determination

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Song [College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, Jiangsu 211816 (China); School of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); Tian, GuiYun, E-mail: tian280@hotmail.com [School of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); School of Electrical and Electronic Engineering, Merz Court, University of Newcastle upon Tyne, Newcastle NE1 7RU (United Kingdom); Dobmann, Gerd; Wang, Ping [School of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China)

    2017-01-01

    Skewness of Magnetic Barkhausen Noise (MBN) signal is used as a new feature for applied stress determination. After experimental studies, skewness presents its ability for measuring applied tensile stress compared with conventional feature, meanwhile, a non-linear behavior of this new feature and an independence of the excitation conditions under compressive stress are found and discussed. Effective damping during domain wall motion influencing the asymmetric shape of the MBN statistical distribution function is discussed under compressive and tensile stress variation. Domain wall (DW) energy and distance between pinning edges of the DW are considered altering the characteristic relaxation time, which is the reason for the non-linear phenomenon of skewness. - Highlights: • The skewness of magnetic Barkhausen noise profile is proposed as a new feature for applied stress determination. • The skewness is sensitive to applied stress and independent to excitation frequency. • Domain wall energy and pinning distance influence the relaxation time of domain wall, which leads to a non-linear behavior of skewness under compressive stress.

  6. Magnetic modes in superlattices

    International Nuclear Information System (INIS)

    Oliveira, F.A.

    1990-04-01

    A first discussion of reciprocal propagation of magnetic modes in a superlattice is presented. In the absence of an applied external magnetic field a superllatice made of alternate layers of the type antiferromagnetic-non-magnetic materials presents effects similar to those of phonons in a dielectric superlattice. (A.C.A.S.) [pt

  7. A model for external drift kriging with uncertain covariates applied to air quality measurements and dispersion model output

    NARCIS (Netherlands)

    Kassteele, van de J.; Stein, A.

    2006-01-01

    We present a method that combines uncertain air quality measurements with uncertain secondary information from an atmospheric dispersion model. The method combines external drift kriging and a measurement error (ME) model, and uses Bayesian techniques for inference. An illustration with simulated

  8. Simulation study of magnetically insulated power coupling to the applied-B ion diode

    International Nuclear Information System (INIS)

    Rosenthal, S.E.

    1992-01-01

    Power coupling to the applied-B ion diode from magnetically insulated transmission lines is simply described in terms of the voltage-current characteristics of both the diode and the transmission line. The accelerator load line intersects the composite characteristic at the operating voltage and current. Using 2-D PIC simulation, the authors have investigated how modification of either the ion diode or the magnetically insulated transmission line characteristic influences power coupling. Plasma prefill can modify the ion diode characteristic; a partially opened POS in the transmission line upstream of the ion diode is a possible cause of modification of the magnetically insulated transmission line characteristic. It can be useful to consider these two aspects of power coupling separately, but they are actually not independent. A good parameter to characterize the situation is the flow impedance, given by V/(I a 2 I c 2 ) 1/2 . V is the line voltage; I a and I c are the conduction currents flowing through the anode and cathode, respectively. The flow impedance covers a range from one half the vacuum impedance, for saturated magnetically insulated flow, to just below the vacuum impedance, for highly unsaturated flow. As the term ''flow impedance'' implies, low flow impedance coincides with greater electron flow while high flow impedance coincides with less electron flow. The flow impedance is sensitive to both the transmission line and the diode impedance. They show how the two are related, using the flow impedance as a parameter

  9. Pressure effects of the magnetic structures of TbNi2Si2 in external fields

    International Nuclear Information System (INIS)

    Kawano, S.; Fukui, S.; Onodera, A.; Amita, F.; Katano, S.

    1997-01-01

    Single crystal neutron diffraction studies of the field-induced magnetic structures of TbNi 2 Si 2 have been performed at 1.7 K without pressure and under 0.7 GPa using a cryomagnetic high pressure system. Without pressure at 1.7 K four intermediate structures have been identified between a zero-field simple antiferromagnetic structure and a fully ferromagnetic one. Under 0.7 GPa two field-induced phases with an antiphase-type modulation along the left angle 110 right angle direction was newly observed above 4 T, while below 3.3 T zero pressure structures are still retained. (orig.)

  10. Studying internal and external magnetic fields in Japan using MAGSAT data

    Science.gov (United States)

    Fukushima, N. (Principal Investigator); Maeda, H.; Yukutake, T.; Tanaka, M.; Oshima, S.; Ogawa, K.; Kawamura, M.; Miyazaki, Y.; Uyeda, S.; Kobayashi, K.

    1980-01-01

    Examination of the total intensity data of CHRONIT on a few paths over Japan and its neighboring sea shows MAGSAT is extremely useful for studying the local magnetic anomaly. In high latitudes, the signatures of field aligned currents are clearly recognized. These include (1) the persistent basic pattern of current flow; (2) the more intense currents in the summer hemisphere than in the winter hemisphere; (3) more fluctuations in current intensities in summer dawn hours; and (4) apparent dawn-dusk asymmetry in the field-aligned current intensity between the north and south polar regions.

  11. Prototyping and testing of the Continuous External Rogowski ITER magnetic sensor

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, Ph., E-mail: philippe.jacques.moreau@cea.fr [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Le-Luyer, A.; Malard, P.; Pastor, P.; Saint-Laurent, F.; Spuig, P. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Lister, J.; Toussaint, M.; Marmillod, P.; Testa, D. [Centre de Recherches en Physique des Plasmas, EPFL (Switzerland); Peruzzo, S. [Consorzio RFX, Association EURATOM-ENEA, C.so Stati Uniti 4, 35127 Padova (Italy); Knaster, J. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); IFMIF EVEDA, Rokkasho (Japan); Vayakis, G.; Hughes, S.; Patel, K.M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: ► ITER Continuous External Rogowski (CER) are designed for plasma and vacuum vessel current measurement. ► CER are located in the casing of Toroidal Field Coils and thus will operate at 4 K. ► The design of the sensors has been completed. ► CER prototypes have been manufactured by 2 suppliers. ► The R and D campaign on CER prototypes consisted in the measurement of about 100 parameters to characterize the CER. -- Abstract: The measurement of the plasma current in ITER plays an outstanding role as it is part of the machine protection and is a safety-relevant measurement: it will be used in relation with regulatory limits to show that the operation remains within the safe envelope defined in the ITER license. The Continuous External Rogowski (CER) is an inductive sensor designed for current measurements and located in the casing of 3 Toroidal Field Coils (TFCs). After the completion of the design of the CER, 4 prototypes of the sensor were manufactured and R and D activities were performed under a Grant with the European Domestic Agency (F4E-GRT-012). The work was carried out between 2010 and 2011 by the ITERMAG consortium comprising 3 laboratories: CRPP (Switzerland) as leader, CEA (France) and RFX (Italy). The R and D campaign on CER prototypes consisted in the measurement of about 100 parameters to characterize the CER in terms of electrical, thermal, mechanical and also of vacuum compatibility. From these results, electromagnetic modeling of the CER response was performed. It is demonstrated that the CER fulfills ITER requirements. However, the vacuum compatibility of the prototype has to be improved and solutions to cope with this issue are proposed.

  12. Molecular dynamics study of response of liquid N,N-dimethylformamide to externally applied electric field using a polarizable force field

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Weimin; Niu, Haitao; Lin, Tong; Wang, Xungai; Kong, Lingxue [Institute for Frontier Materials, Deakin University, Waurn Ponds VIC 3216 (Australia)

    2014-01-28

    The behavior of Liquid N,N-dimethylformamide subjected to a wide range of externally applied electric fields (from 0.001 V/nm to 1 V/nm) has been investigated through molecular dynamics simulation. To approach the objective the AMOEBA polarizable force field was extended to include the interaction of the external electric field with atomic partial charges and the contribution to the atomic polarization. The simulation results were evaluated with quantum mechanical calculations. The results from the present force field for the liquid at normal conditions were compared with the experimental and molecular dynamics results with non-polarizable and other polarizable force fields. The uniform external electric fields of higher than 0.01 V/nm have a significant effect on the structure of the liquid, which exhibits a variation in numerous properties, including molecular polarization, local cluster structure, rotation, alignment, energetics, and bulk thermodynamic and structural properties.

  13. Fermi Surface Manipulation by External Magnetic Field Demonstrated for a Prototypical Ferromagnet

    Directory of Open Access Journals (Sweden)

    E. Młyńczak

    2016-12-01

    Full Text Available We consider the details of the near-surface electronic band structure of a prototypical ferromagnet, Fe(001. Using high-resolution angle-resolved photoemission spectroscopy, we demonstrate openings of the spin-orbit-induced electronic band gaps near the Fermi level. The band gaps, and thus the Fermi surface, can be manipulated by changing the remanent magnetization direction. The effect is of the order of ΔE=100  meV and Δk=0.1  Å^{−1}. We show that the observed dispersions are dominated by the bulk band structure. First-principles calculations and one-step photoemission calculations suggest that the effect is related to changes in the electronic ground state and not caused by the photoemission process itself. The symmetry of the effect indicates that the observed electronic bulk states are influenced by the presence of the surface, which might be understood as related to a Rashba-type effect. By pinpointing the regions in the electronic band structure where the switchable band gaps occur, we demonstrate the significance of spin-orbit interaction even for elements as light as 3d ferromagnets. These results set a new paradigm for the investigations of spin-orbit effects in the spintronic materials. The same methodology could be used in the bottom-up design of the devices based on the switching of spin-orbit gaps such as electric-field control of magnetic anisotropy or tunneling anisotropic magnetoresistance.

  14. Influence of external magnetic field on thermophysical parameters of magnetic fluid based on aqueous hydrogen peroxide or ethylene glycol with a mixture of lanthanum manganite powder and toner printer cartridge

    Science.gov (United States)

    Zaripov, Jamshed; Borisov, Boris

    2014-08-01

    Heat transfer agent magnetic fluids based on aqueous solutions of hydrogen peroxide or a mixture of ethylene glycol with the powders of lanthanum manganite and the toner cartridge are considered. Experimental data on the effect produced by an external magnetic field on the characteristics of magnetic fluids and heat exchanger efficiency were analyzed. As the heat exchanger is considered flat-plate solar collector. The conclusion about the possibility of using the above technologies to improve the efficiency of heat exchangers.

  15. Influence of AC external magnetic field perturbation on the guidance force of HTS bulk over a NdFeB guideway

    International Nuclear Information System (INIS)

    Zhang Longcai; Wang Jiasu; Wang Suyu; He Qingyong

    2007-01-01

    Superconducting maglev vehicle system requires that the surface magnetic field of the guideway is uniform along the forward direction. But in practice the surface magnetic field of the NdFeB permanent magnet guideway is not always immutable. So the HTS bulks in this case are exposed to AC external magnetic field, which may induce the energy loss in the bulk and influence the guidance force between the HTS bulks and the NdFeB guideway. In this paper, we experimentally studied the influence of the AC external magnetic field perturbation on the guidance force of a HTS bulk over the NdFeB guideway. The experimental results showed that the guidance force was influenced by the application of the AC external magnetic. The guidance fore hysteresis became more evident with the amplitude of the AC field and was independent of the frequency in the range 90-400 Hz. We attributed the reason to magnetic hysteresis loss in the superconductor

  16. Influence of AC external magnetic field perturbation on the guidance force of HTS bulk over a NdFeB guideway

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Longcai [Applied Superconductivity Laboratory, Southwest Jiaotong University, P.O. Box 152, Chengdu, Sichuan 610031 (China)]. E-mail: zhlcai2000@163.com; Wang Jiasu [Applied Superconductivity Laboratory, Southwest Jiaotong University, P.O. Box 152, Chengdu, Sichuan 610031 (China); Wang Suyu [Applied Superconductivity Laboratory, Southwest Jiaotong University, P.O. Box 152, Chengdu, Sichuan 610031 (China); He Qingyong [Applied Superconductivity Laboratory, Southwest Jiaotong University, P.O. Box 152, Chengdu, Sichuan 610031 (China)

    2007-08-01

    Superconducting maglev vehicle system requires that the surface magnetic field of the guideway is uniform along the forward direction. But in practice the surface magnetic field of the NdFeB permanent magnet guideway is not always immutable. So the HTS bulks in this case are exposed to AC external magnetic field, which may induce the energy loss in the bulk and influence the guidance force between the HTS bulks and the NdFeB guideway. In this paper, we experimentally studied the influence of the AC external magnetic field perturbation on the guidance force of a HTS bulk over the NdFeB guideway. The experimental results showed that the guidance force was influenced by the application of the AC external magnetic. The guidance fore hysteresis became more evident with the amplitude of the AC field and was independent of the frequency in the range 90-400 Hz. We attributed the reason to magnetic hysteresis loss in the superconductor.

  17. Functional magnetic resonance imaging study of external source memory and its relation to cognitive insight in non-clinical subjects.

    Science.gov (United States)

    Buchy, Lisa; Hawco, Colin; Bodnar, Michael; Izadi, Sarah; Dell'Elce, Jennifer; Messina, Katrina; Lepage, Martin

    2014-09-01

    Previous research has linked cognitive insight (a measure of self-reflectiveness and self-certainty) in psychosis with neurocognitive and neuroanatomical disturbances in the fronto-hippocampal neural network. The authors' goal was to use functional magnetic resonance imaging (fMRI) to investigate the neural correlates of cognitive insight during an external source memory paradigm in non-clinical subjects. At encoding, 24 non-clinical subjects travelled through a virtual city where they came across 20 separate people, each paired with a unique object in a distinct location. fMRI data were then acquired while participants viewed images of the city, and completed source recognition memory judgments of where and with whom objects were seen, which is known to involve prefrontal cortex. Cognitive insight was assessed with the Beck Cognitive Insight Scale. External source memory was associated with neural activity in a widespread network consisting of frontal cortex, including ventrolateral prefrontal cortex (VLPFC), temporal and occipital cortices. Activation in VLPFC correlated with higher self-reflectiveness and activation in midbrain correlated with lower self-certainty during source memory attributions. Neither self-reflectiveness nor self-certainty significantly correlated with source memory accuracy. By means of virtual reality and in the context of an external source memory paradigm, the study identified a preliminary functional neural basis for cognitive insight in the VLPFC in healthy people that accords with our fronto-hippocampal theoretical model as well as recent neuroimaging data in people with psychosis. The results may facilitate the understanding of the role of neural mechanisms in psychotic disorders associated with cognitive insight distortions. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  18. Critical current, phase slip centers and phase slip lines in superconducting films in zero external magnetic field

    International Nuclear Information System (INIS)

    Dmitriev, V.M.; Zolochevskii, I.V.; Salenkova, T.V.; Khristenko, E.V.

    2005-01-01

    The temperature dependences of current-voltage characteristics have been measured on high-grade thin Sn films (7-50 micron wide) in zero external magnetic field. For the first time we could observe on the same samples phase slip centers (PSC) near Tc, where the samples were narrow channels, and phase slip lines (PSL) at lower temperatures when the films become wide. In this case the critical current experiences a temperature crossover which affects absolute value of the critical current while the temperature dependence of the (1-T/Tc) 3/2 type persists in a certain temperature interval. On further the temperature lowering, the critical current at which vortices due to the self-field of the current enter the sample has a linear temperature dependence and correlates with the Aslamazov-Lempitsky theory. With lowering temperature the onset of the crossover occurs at a temperature at which the film width becomes equal to the fourfold penetration depth of the weak magnetic field perpendicular to the film plane. On each side of this equality the films are either narrow or wide. The current of the formation of the first PSC is the Ginzburg-Landau critical current of pair breaking which is distributed uniformly over the film width. The current of the formation of the first PSL is the current of the vortex - state instability predicted by Aslamazov and Lempitsky. It is distributed specifically over the sample width

  19. Quasilongitudinal soliton in a two-dimensional strongly coupled complex dusty plasma in the presence of an external magnetic field.

    Science.gov (United States)

    Ghosh, Samiran

    2014-09-01

    The propagation of a nonlinear low-frequency mode in two-dimensional (2D) monolayer hexagonal dusty plasma crystal in presence of external magnetic field and dust-neutral collision is investigated. The standard perturbative approach leads to a 2D Korteweg-de Vries (KdV) soliton for the well-known dust-lattice mode. However, the Coriolis force due to crystal rotation and Lorentz force due to magnetic field on dust particles introduce a linear forcing term, whereas dust-neutral drag introduce the usual damping term in the 2D KdV equation. This new nonlinear equation is solved both analytically and numerically to show the competition between the linear forcing and damping in the formation of quasilongitudinal soliton in a 2D strongly coupled complex (dusty) plasma. Numerical simulation on the basis of the typical experimental plasma parameters and the analytical solution reveal that the neutral drag force is responsible for the usual exponential decay of the soliton, whereas Coriolis and/or Lorentz force is responsible for the algebraic decay as well as the oscillating tail formation of the soliton. The results are discussed in the context of the plasma crystal experiment.

  20. Research of transportation efficiency of low-energy high- current electron beam in plasma channel in external magnetic field

    International Nuclear Information System (INIS)

    Vagin, E S; Grigoriev, V P

    2015-01-01

    Effective high current (5-20 kA) and low energy (tens of keV) electrons beam transportation is possible only with almost complete charging neutralization. It is also necessary to use quite high current neutralization for elimination beam self-pinching effect. The research is based on the self-consistent mathematical model that takes into account beam and plasma particles dynamic, current and charge neutralization of electron beam and examines the transportation of electron beam into a chamber with low-pressure plasma in magnetic field. A numerical study was conducted using particle in cell (PIC) method. The study was performed with various system parameters: rise time and magnitude of the beam current, gas pressure and plasma density and geometry of the system. Regularities of local virtual cathode field generated by the beam in the plasma channel, as well as ranges of parameters that let transportation beam with minimal losses, depending on the external magnetic field were determined through a series of numerical studies. In addition, the assessment of the impact of the plasma ion mobility during the transition period and during steady beam was performed. (paper)

  1. Templating Biomineralization: Surface Directed Protein Self-assembly and External Magnetic Field Stimulation of Osteoblasts

    Science.gov (United States)

    Ba, Xiaolan

    Biomineralization is a wide-spread phenomenon in the biological systems, which is the process of mineral formation by organisms through interaction between its organic contents and the inorganic minerals. The process is essential in a broad spectrum of biological phenomena ranging from bone and tooth formation to pathological mineralization under hypoxic conditions or cancerous formations. In this thesis I studied biomineralization at the earliest stages in order to obtain a better understanding of the fundamental principals involved. This knowledge is essential if we want to engineer devices which will increase bone regeneration or prevent unwanted mineral deposits. Extracellular matrix (ECM) proteins play an essential role during biomineralization in bone and engineered tissues. In this dissertation, I present an approach to mimic the ECM in vitro to probe the interactions of these proteins with calcium phosphate mineral and with each other. Early stage of mineralization is investigated by mechanical properties of the protein fibers using Scanning Probe Microscopy (SPM) and Shear Modulation Force Microscopy (SMFM). The development of mineral crystals on the protein matrices is also characterized by Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and Grazing Incidence X-ray Diffraction (GIXRD). The results demonstrate complementary actions of the two ECM proteins to collect cations and template calcium phosphate mineral, respectively. Magnets have been clinically used as an "induction source" in various bone or orthodontic treatments. However, the mechanism and effects of magnetic fields remain unclear. In this dissertation, I also undertake the present investigation to study the effects of 150 mT static magnetic fields (SMF) on ECM development and cell biomineralization using MC3T3-E1 osteobalst-like cells. Early stage of biomineralization is characterized by SPM, SMFM and confocal laser scanning microscopy (CSLM). Late stage of

  2. Influence of external magnetic field, finite-size effects and chemical potential on the phase transition of a complex scalar field

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti, E.; Castro, E.; Malbouisson, A.P.C. [Centro Brasileiro de Pesquisas Fisicas/MCTI, Rio de Janeiro, RJ (Brazil); Linhares, C.A. [Universidade do Estado do Rio de Janeiro, Instituto de Fisica, Rio de Janeiro, RJ (Brazil)

    2017-10-15

    A scalar model is built, as a quantum field theory defined on a toroidal topology, to describe a phase transition in films subjected to periodic boundary conditions and influenced by an external and constant magnetic field. Criticality is studied and the relations between the critical temperature, the film thickness, the magnetic field strength and the chemical potential are investigated. Since the model describes a second-order phase transition a comparison with the Ginzburg-Landau theory is made. (orig.)

  3. Poor Reliability between Cochrane Reviewers and Blinded External Reviewers When Applying the Cochrane Risk of Bias Tool in Physical Therapy Trials

    OpenAIRE

    Armijo-Olivo, Susan; Ospina, Maria; Da Costa, Bruno R; Egger, Matthias; Saltaji, Humam; Fuentes, Jorge; Ha, Christine; Cummings, Greta G.

    2014-01-01

    OBJECTIVES To test the inter-rater reliability of the RoB tool applied to Physical Therapy (PT) trials by comparing ratings from Cochrane review authors with those of blinded external reviewers. METHODS Randomized controlled trials (RCTs) in PT were identified by searching the Cochrane Database of Systematic Reviews for meta-analysis of PT interventions. RoB assessments were conducted independently by 2 reviewers blinded to the RoB ratings reported in the Cochrane reviews. Data on...

  4. Radiographic evaluation of vessel count and density with quantitative magnetic resonance imaging during external breast expansion in Asian women: A prospective clinical trial.

    Science.gov (United States)

    Myung, Yujin; Kwon, Heeyeon; Pak, Changsik; Lee, Hobin; Jeong, Jae Hoon; Heo, Chan Yeong

    2016-12-01

    Breast augmentation with fat transfer does not bear the risks associated with silicone implantation. The method can potentially be especially useful in Asian women, who often reject augmentation mammoplasty with implants. This prospective clinical trial evaluated the effects of external breast expansion on breast density and vessel count using magnetic resonance imaging. Thirty-four enrolled patients were instructed to apply one of two devices, the conventional BRAVA device (used in the AESTES trial) or a novel external expansion device (EVERA) designed for Asian women, continuously for 8 h per day for 12 weeks. For external expansion, the pressure was set to 25 mmHg. Follow-up examinations were performed for 4 weeks after completion of the expansion. The ratio between the fibroglandular and adipose tissues of the breast was measured using T1-weighted MRI, and the number of vessels in the breast tissue was determined before and after the treatment by contrast MRI. Additionally, the volume of the breast was measured by laser scanning before, during, and after the device application. The obtained measurements were compared within and between the groups at different time points. Six patients dropped out, while 28 completed the trial without major side effects or adverse events. External expansion significantly increased breast vessel count in both the EVERA and AESTES groups (p = 0.019, p = 0.022). However, it did not significantly change breast density in either group (p = 0.186, p = 0.638). No significant intergroup differences were noted in vessel count (p = 0.874) or density (p = 0.482). Breast volume increases after 12 weeks of application were statistically significant in both groups, with mean changes of 81 ± 22 cc (AESTES) and 98 ± 30 cc (EVERA) (p Asian women. Level II, therapeutic study. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Ultrasound studies of single crystal thulium in an applied magnetic field

    International Nuclear Information System (INIS)

    Lim, C.M.; Edwards, C.; Dixon, S.; Palmer, S.B.

    2001-01-01

    The paper reports the first measurements of the single crystal elastic constants of the heavy rare earth metal thulium as a function of temperature and magnetic field. The constants were obtained from ultrasonic velocity measurements over a temperature range of 4.2-296 K and in applied magnetic fields of up to 5 T. The elastic constants; C 11 , C 33 , C 44 and C 66 =(C 11 -C 12 )/2 were determined from the ultrasonic velocities. Anomalies in the elastic constants were observed at 58 K from the c-axis propagated shear wave measurements and at 55 K from the c-axis propagated longitudinal wave measurements. Significant softening of the elastic constants C 33 and C 44 was observed close to T N . Application of a magnetic field (>2 T) along the c-axis direction induced further softening of the material. Electromagnetic acoustic transducers (EMATs) were also employed in addition to conventional piezoelectric quartz transducers. A marked increase in the EMATs acoustic coupling efficiency (generation and detection efficiency) occurred close to T N

  6. Experimental investigation of an active magnetic regenerative heat circulator applied to self-heat recuperation technology

    International Nuclear Information System (INIS)

    Kotani, Yui; Kansha, Yasuki; Ishizuka, Masanori; Tsutsumi, Atsushi

    2014-01-01

    An experimental investigation into an active magnetic regenerative (AMR) heat circulator based on self-heat recuperation technology, was conducted to evaluate its energy saving potential in heat circulation. In an AMR heat circulator, magnetocaloric effect is applied to recuperate the heat exergy of the process fluid. The recuperated heat can be reused to heat the feed process fluid and realize self-heat recuperation. In this paper, AMR heat circulator has newly been constructed to determine the amount of heat circulated when applied to self-heat recuperation and the energy consumption of the heat circulator. Gadolinium and water was used as the magnetocaloric working material and the process fluid, respectively. The heat circulated amount was determined by measuring the temperature of the process fluid and gadolinium. The net work input for heat circulation was obtained from the magnetizing and demagnetizing forces and the distance travelled by the magnetocaloric bed. The results were compared with the minimum work input needed for heat circulation derived from exergy loss during heat exchange. It was seen that the experimentally obtained value was close to the minimum work input needed for heat circulation. - Highlights: • AMR heat circulator has newly been constructed for experimental evaluation. • Heat circulation in the vicinity of Curie temperature was observed. • Energy consumption of an AMR heat circulator has been measured. • Energy saving for processes near Curie temperature of working material was seen

  7. Interdisciplinary approaches of transcranial magnetic stimulation applied to a respiratory neuronal circuitry model.

    Directory of Open Access Journals (Sweden)

    Stéphane Vinit

    Full Text Available Respiratory related diseases associated with the neuronal control of breathing represent life-threatening issues and to date, no effective therapeutics are available to enhance the impaired function. The aim of this study was to determine whether a preclinical respiratory model could be used for further studies to develop a non-invasive therapeutic tool applied to rat diaphragmatic neuronal circuitry. Transcranial magnetic stimulation (TMS was performed on adult male Sprague-Dawley rats using a human figure-of-eight coil. The largest diaphragmatic motor evoked potentials (MEPdia were recorded when the center of the coil was positioned 6 mm caudal from Bregma, involving a stimulation of respiratory supraspinal pathways. Magnetic shielding of the coil with mu metal reduced magnetic field intensities and improved focality with increased motor threshold and lower amplitude recruitment curve. Moreover, transynaptic neuroanatomical tracing with pseudorabies virus (applied to the diaphragm suggest that connections exist between the motor cortex, the periaqueductal grey cell regions, several brainstem neurons and spinal phrenic motoneurons (distributed in the C3-4 spinal cord. These results reveal the anatomical substrate through which supraspinal stimulation can convey descending action potential volleys to the spinal motoneurons (directly or indirectly. We conclude that MEPdia following a single pulse of TMS can be successfully recorded in the rat and may be used in the assessment of respiratory supraspinal plasticity. Supraspinal non-invasive stimulations aimed to neuromodulate respiratory circuitry will enable new avenues of research into neuroplasticity and the development of therapies for respiratory dysfunction associated with neural injury and disease (e.g. spinal cord injury, amyotrophic lateral sclerosis.

  8. Developments in Understanding Stability as Applied to Magnetic Levitated Launch Assist

    Science.gov (United States)

    Gering, James A.

    2002-01-01

    Magnetic levitation is a promising technology, with the potential of constituting the first stage of a third generation space transportation system. Today, the Space Shuttle burns on the order of one million pounds of solid rocket propellant to bring the orbiter and external tank to nearly Mach 1 (1,000 kph). Imagine the reductions in launch vehicle weight, complexity and risk if an aerospace vehicle could be accelerated to the same speed utilizing about $1,000 of off-board electrical energy stored in flywheels. After over two decades of development, maglev trains travel on full-scale demonstration tracks in Germany and Japan reaching speeds approaching 500 kph. Encouraging as this may appear, the energy and power required to accelerate a 1 million pound launch vehicle to 1,000 kph would radically redefine the state-of-the-art in electrical energy storage and delivery. Reaching such a goal will require levitation with sufficient stability to withstand an operating environment fundamentally different from that of a high-speed train. Recently NASA let contracts for the construction of three maglev demonstration tracks. This construction and several associated trade studies represent a first-order investigation into the feasibility of maglev launch assist. This report provides a review of these efforts, other government sponsored maglev projects and additional technical literature pertinent to maglev stability. This review brings to light details and dimensions of the maglev stability problem which are not found in previous NASA-sponsored trade studies and which must be addressed in order to realize magnetic levitation as a launch assist technology.

  9. Development of an experimental system for characterization of high-temperature superconductors cooled by liquid hydrogen under the external magnetic field

    International Nuclear Information System (INIS)

    Tatsumoto, H; Shirai, Y; Shiotsu, M; Naruo, Y; Kobayashi, H; Inatani, Y

    2014-01-01

    An experimental system has been developed to investigate electro-magnetic properties of high-Tc superconductors cooled by liquid hydrogen under the external magnetic field of up to 7 T. A LH 2 cryostat is concentrically mounted on the inside of a LHe cryostat to cool a NbTi superconducting magnet. The experimental system is installed in an explosion-proof room. Explosion proof electrical devices are used and current leads are covered with an enclosure filled with nitrogen gas. A remote control system has been developed. Furthermore, the effects of stray magnetic field on the existing and the new devices are investigated and electro-magnetic shielding panels and enclosure made of iron were designed. It is confirmed through the cryogenic test that the experimental system meets the design requirements.

  10. A study on the impediment of thickness diminution of Carbon steel tube by using a applied magnetic field

    International Nuclear Information System (INIS)

    Kim, Jong Oh; Kim, Jong Hui; Cho, Wan Sik; Hong, Sung Min; Park, Yun Won

    2001-03-01

    Magnetic properties of the carbon steel tube which is used as the pipe laying of cooling water in nuclear power plant were measured to research the impediment of thickness diminution of carbon steel tube. Magnetic field distribution of carbon steel tube in the applied magnetic field was simulated by computer program. On the basis of the simulation results, Alnico 5DG and Alnico 5 were selected as the permanent magnets applicable to the carbon steel tube. Sm2Co17 magnet was used to compare the performance of permanent magnets. The experimental apparatus similar to the draining environment of cooling water in nuclear power plant was also manufactured in order to research the impediment of thickness diminution of carbon steel carbon tube

  11. Flow of liquid metals with a transversely applied magnetic field, (8)

    International Nuclear Information System (INIS)

    Arai, Shigeki; Tomita, Yukio; Sudou, Kouzou

    1977-01-01

    As one of the researches of liquid metal flow in transversely applied magnetic field concerning the flow in MHD pipes, the influences of the electrical property of channel side walls, aspect ratio, Reynolds number and Hartmann number on laminar and transition flows investigated experimentally are reported in this paper. Mercury flowed in the rectangular ducts, one of which was made with four insulated walls, and another with insulated top and bottom walls and two conductive side walls, with the aspect ratio varying from 8 to 1/8, in the region of relatively low Hartmann number and Reynolds number. The facility, procedure and results of the experiment are explained, and many experimental curves showing the relations among pipe friction coefficient, Hartmann number, Reynolds number, aspect ratio and the property of walls are given. The experimental results show that the Hartmann effect and the aspect ratio effect are evident as the magnetic field is intensified, but the influence by the electric property of walls is little, and three shapes of the curves representing the relation of friction coefficient and Reynolds number are confirmed by this experiment. (auth.)

  12. Hybrid instrument applied to human reliability study in event of loss of external electric power in a nuclear power plant

    International Nuclear Information System (INIS)

    Martins, Eduardo Ferraz

    2015-01-01

    The study projects in highly complex installations involves robust modeling, supported by conceptual and mathematical tools, to carry out systematic research and structured the different risk scenarios that can lead to unwanted events from occurring equipment failures or human errors. In the context of classical modeling, the Probabilistic Safety Analysis (PSA) seeks to provide qualitative and quantitative information about the project particularity and their operational facilities, including the identification of factors or scenarios that contribute to the risk and consequent comparison options for increasing safety. In this context, the aim of the thesis is to develop a hybrid instrument (CPP-HI) innovative, from the integrated modeling techniques of Failure Mode and Effect Analysis (FMEA), concepts of Human Reliability Analysis and Probabilistic Composition of Preferences (PCP). In support of modeling and validation of the CPP-HI, a simulation was performed on a triggering event 'Loss of External Electric Power' - PEEE, in a Nuclear Power plant. The results were simulated in a virtual environment (sensitivity analysis) and are robust to the study of Human Reliability Analysis (HRA) in the context of the PSA. (author)

  13. Phase incremented echo train acquisition applied to magnetic resonance pore imaging

    Science.gov (United States)

    Hertel, S. A.; Galvosas, P.

    2017-02-01

    Efficient phase cycling schemes remain a challenge for NMR techniques if the pulse sequences involve a large number of rf-pulses. Especially complex is the Carr Purcell Meiboom Gill (CPMG) pulse sequence where the number of rf-pulses can range from hundreds to several thousands. Our recent implementation of Magnetic Resonance Pore Imaging (MRPI) is based on a CPMG rf-pulse sequence in order to refocus the effect of internal gradients inherent in porous media. While the spin dynamics for spin- 1 / 2 systems in CPMG like experiments are well understood it is still not straight forward to separate the desired pathway from the spectrum of unwanted coherence pathways. In this contribution we apply Phase Incremented Echo Train Acquisition (PIETA) to MRPI. We show how PIETA offers a convenient way to implement a working phase cycling scheme and how it allows one to gain deeper insights into the amplitudes of undesired pathways.

  14. Vortex configuration in the presence of local magnetic field and locally applied stress

    International Nuclear Information System (INIS)

    Wissberg, Shai; Kremen, Anna; Shperber, Yishai; Kalisky, Beena

    2017-01-01

    Highlights: • We discuss different ways to determine vortex configuration using a scanning SQUID. • We determined the vortex configuration by approaching the sample during cooling. • We observed an accumulation of vortices when contact was made with the sample. • We show how we can manipulate local vortex configuration using contact. - Abstract: Vortex configuration is determined by the repulsive interaction, which becomes dominant with increasing vortex density, by the pinning potential, and by other considerations such as the local magnetic fields, currents flowing in the sample, or as we showed recently, by local stress applied on the sample. In this work we describe different ways to control vortex configuration using scanning SQUID microscopy.

  15. Vortex configuration in the presence of local magnetic field and locally applied stress

    Energy Technology Data Exchange (ETDEWEB)

    Wissberg, Shai; Kremen, Anna; Shperber, Yishai; Kalisky, Beena, E-mail: beena@biu.ac.il

    2017-02-15

    Highlights: • We discuss different ways to determine vortex configuration using a scanning SQUID. • We determined the vortex configuration by approaching the sample during cooling. • We observed an accumulation of vortices when contact was made with the sample. • We show how we can manipulate local vortex configuration using contact. - Abstract: Vortex configuration is determined by the repulsive interaction, which becomes dominant with increasing vortex density, by the pinning potential, and by other considerations such as the local magnetic fields, currents flowing in the sample, or as we showed recently, by local stress applied on the sample. In this work we describe different ways to control vortex configuration using scanning SQUID microscopy.

  16. Computerization of effluent management and external dose calculation using the 'ODCM' methodology applied to Almaraz-NPP

    International Nuclear Information System (INIS)

    Garcia Gutierrez, M.E.; Sustacha Duo, D.

    1993-01-01

    The ODCM (Offsite Dose Calculation Manual), the official operational document for all nuclear power plants develops the details for the technical specifications for discharges and governs their practical application. The use of ODCM methodology for managing and controlling data associated with radioactive discharges, as well as the subsequent processing of this data to assess the radiological impact, requires and generates a large volume of data, which demands the frequent application of laborious and complex calculation processes, making computerization necessary. The computer application created for Almaraz NPP has the capacity to store and manage data on all discharges, evaluate their effects, presents reports and copies the information to be sent periodically to the CSN (Spanish Nuclear Regulatory Commission) on a magnetic tape. The radiological impact of an actual or possible discharge can be evaluated at anytime and, furthermore, general or particular reports and graphs on the discharges and doses over time can be readily obtained. The application is run on a personal computer under a relational database management system. This interactive application is based on menus and windows. (author)

  17. Using LDR as Sensing Element for an External Fuzzy Controller Applied in Photovoltaic Pumping Systems with Variable-Speed Drives

    Science.gov (United States)

    Maranhão, Geraldo Neves De A.; Brito, Alaan Ubaiara; Leal, Anderson Marques; Fonseca, Jéssica Kelly Silva; Macêdo, Wilson Negrão

    2015-01-01

    In the present paper, a fuzzy controller applied to a Variable-Speed Drive (VSD) for use in Photovoltaic Pumping Systems (PVPS) is proposed. The fuzzy logic system (FLS) used is embedded in a microcontroller and corresponds to a proportional-derivative controller. A Light-Dependent Resistor (LDR) is used to measure, approximately, the irradiance incident on the PV array. Experimental tests are executed using an Arduino board. The experimental results show that the fuzzy controller is capable of operating the system continuously throughout the day and controlling the direct current (DC) voltage level in the VSD with a good performance. PMID:26402688

  18. "To whom do the results of this trial apply?" External validity of a randomized controlled trial involving 130 patients scheduled for primary total hip replacement

    DEFF Research Database (Denmark)

    Petersen, Mette K; Andersen, Karen Vestergaard; Andersen, Niels T

    2007-01-01

    BACKGROUND: Although the randomized controlled trial (RCT) is regarded as the gold standard for evaluation of the effect of an intervention, its external validity has been questioned. RCTs cannot be expected to produce results that are directly relevant to all patients and all settings, but they ......BACKGROUND: Although the randomized controlled trial (RCT) is regarded as the gold standard for evaluation of the effect of an intervention, its external validity has been questioned. RCTs cannot be expected to produce results that are directly relevant to all patients and all settings......, but they should at least allow patients and clinicians to judge to whom trial results can reasonably be applied. We assessed the external validity of an RCT investigating the efficacy of a fast-track program after total hip replacement. METHODS: 130 patients were identified as potential participants.18 patients...... were excluded, 33 enrolled patients declined to participate, and 79 patients were enrolled and randomized. We studied the distribution of preoperative characteristics and postoperative clinical variables in these 3 groups. RESULTS: A significant difference was found in both preoperative characteristics...

  19. Targeted drug delivery to magnetic implants for therapeutic applications

    International Nuclear Information System (INIS)

    Yellen, Benjamin B.; Forbes, Zachary G.; Halverson, Derek S.; Fridman, Gregory; Barbee, Kenneth A.; Chorny, Michael; Levy, Robert; Friedman, Gary

    2005-01-01

    A new method for locally targeted drug delivery is proposed that employs magnetic implants placed directly in the cardiovascular system to attract injected magnetic carriers. Theoretical simulations and experimental results support the assumption that using magnetic implants in combination with externally applied magnetic field will optimize the delivery of magnetic drug to selected sites within a subject

  20. Poor reliability between Cochrane reviewers and blinded external reviewers when applying the Cochrane risk of bias tool in physical therapy trials.

    Science.gov (United States)

    Armijo-Olivo, Susan; Ospina, Maria; da Costa, Bruno R; Egger, Matthias; Saltaji, Humam; Fuentes, Jorge; Ha, Christine; Cummings, Greta G

    2014-01-01

    To test the inter-rater reliability of the RoB tool applied to Physical Therapy (PT) trials by comparing ratings from Cochrane review authors with those of blinded external reviewers. Randomized controlled trials (RCTs) in PT were identified by searching the Cochrane Database of Systematic Reviews for meta-analysis of PT interventions. RoB assessments were conducted independently by 2 reviewers blinded to the RoB ratings reported in the Cochrane reviews. Data on RoB assessments from Cochrane reviews and other characteristics of reviews and trials were extracted. Consensus assessments between the two reviewers were then compared with the RoB ratings from the Cochrane reviews. Agreement between Cochrane and blinded external reviewers was assessed using weighted kappa (κ). In total, 109 trials included in 17 Cochrane reviews were assessed. Inter-rater reliability on the overall RoB assessment between Cochrane review authors and blinded external reviewers was poor (κ  =  0.02, 95%CI: -0.06, 0.06]). Inter-rater reliability on individual domains of the RoB tool was poor (median κ  = 0.19), ranging from κ  =  -0.04 ("Other bias") to κ  =  0.62 ("Sequence generation"). There was also no agreement (κ  =  -0.29, 95%CI: -0.81, 0.35]) in the overall RoB assessment at the meta-analysis level. Risk of bias assessments of RCTs using the RoB tool are not consistent across different research groups. Poor agreement was not only demonstrated at the trial level but also at the meta-analysis level. Results have implications for decision making since different recommendations can be reached depending on the group analyzing the evidence. Improved guidelines to consistently apply the RoB tool and revisions to the tool for different health areas are needed.

  1. Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields

    International Nuclear Information System (INIS)

    Dimbylow, Peter

    2005-01-01

    This paper outlines the development of a 2 mm resolution voxel model, NAOMI (aNAtOMIcal model), designed to be representative of the average adult female. The primary medical imaging data were derived from a high-resolution MRI scan of a 1.65 m tall, 23 year old female subject with a mass of 58 kg. The model was rescaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the International Commission on Radiological Protection reference adult female. There are 41 tissue types in the model. The application of NAOMI to the calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields is described. Comparisons are made with values from the male voxel model, NORMAN. The calculations were extended from 50 Hz up to 10 MHz. External field reference levels are compared with the ICNIRP guidelines

  2. Comparison of magnetic nondestructive methods applied for inspection of steel degradation

    Czech Academy of Sciences Publication Activity Database

    Takahashi, S.; Kobayashi, S.; Tomáš, Ivan; Dupre, L.; Vértesy, G.

    2017-01-01

    Roč. 91, Jun (2017), s. 54-60 ISSN 0963-8695 R&D Projects: GA ČR GB14-36566G Institutional support: RVO:68378271 Keywords : magnetic hysteresis * magnetic NDT * steel degradation Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.726, year: 2016

  3. Nonlinear dynamics and chaotization of oscillations of a virtual cathode in an annular electron beam in a uniform external magnetic field

    International Nuclear Information System (INIS)

    Kurkin, S. A.; Koronovski, A. A.; Hramov, A. E.

    2009-01-01

    Results are presented from a numerical study of the effect of an external magnetic field on the conditions and mechanisms for the formation of a virtual cathode in a relativistic electron beam. Characteristic features of the nonlinear dynamics of an electron beam with a virtual cathode are considered when the external magnetic field is varied. Various mechanisms are investigated by which the virtual cathode oscillations become chaotic and their spectrum becomes a multifrequency spectrum, thereby complicating the dynamics of the vircator system. A general mechanism for chaotization of the oscillations of a virtual cathode in a vircator system is revealed: the electron structures that form in an electron beam interact by means of a common space charge field to give rise to additional internal feedback. That the oscillations of a virtual cathode change from the chaotic to the periodic regime is due to the suppression of the mechanism for forming secondary electron structures.

  4. Neutron scattering techniques for betaine calcium chloride dihydrate under applied external field (temperature, electric field and hydrostatic pressure)

    International Nuclear Information System (INIS)

    Hernandez, O.

    1997-01-01

    We have studied with neutron scattering techniques betaine calcium chloride dihydrate (BCCD), a dielectric aperiodic crystal which displays a Devil's staircase type phase diagram made up of several incommensurate and commensurate phases, having a range of stability very sensitive to temperature, electric field and hydrostatic pressure. We have measured a global hysteresis of δ(T) of about 2-3 K in the two incommensurate phases. A structural study of the modulated commensurate phases 1/4 and 1/5 allows us to evidence that the atomic modulation functions are anharmonic. The relevance of the modelization of the modulated structure by polar Ising pseudo-spins is then directly established. On the basis of group theory calculation in the four dimensional super-space, we interpret this anharmonic modulation as a soliton regime with respect to the lowest-temperature non modulated ferroelectric phase. The continuous character of the transition to the lowest-temperature non modulated phase and the diffuse scattering observed in this phase are accounted for the presence of ferroelectric domains separated by discommensurations. Furthermore, we have shown that X-rays induce in BCCD a strong variation with time of irradiation of the intensity of satellite peaks, and more specifically for third order ones. This is why the 'X-rays' structural model is found more harmonic than the 'neutron' one. Under electric field applied along the vector b axis, we confirm that commensurate phases with δ = even/odd are favoured and hence are polar along this direction. We have evidenced at 10 kV / cm two new higher order commensurate phases in the phase INC2, corroborating the idea of a 'complete' Devil's air-case phase diagram. A phenomenon of generalized coexistence of phases occurs above 5 kV / cm. We have characterized at high field phase transitions between 'coexisting' phases, which are distinguishable from classical lock-in transitions. Under hydrostatic pressure, our results contradict

  5. Stepwise algorithm using computed tomography and magnetic resonance imaging for diagnosis of fat-poor angiomyolipoma in small renal masses: Development and external validation.

    Science.gov (United States)

    Tanaka, Hajime; Fujii, Yasuhisa; Tanaka, Hiroshi; Ishioka, Junichiro; Matsuoka, Yoh; Saito, Kazutaka; Uehara, Sho; Numao, Noboru; Yuasa, Takeshi; Yamamoto, Shinya; Masuda, Hitoshi; Yonese, Junji; Kihara, Kazunori

    2017-07-01

    To develop a stepwise diagnostic algorithm for fat-poor angiomyolipoma in small renal masses. Two cohorts of small renal masses magnetic resonance imaging and clinical findings were analyzed. Based on multivariate analysis, we developed two prediction models for fat-poor angiomyolipoma, the computed tomography model and the computed tomography + magnetic resonance imaging model, and a stepwise algorithm that proposes the sequential use of computed tomography and magnetic resonance imaging. The computed tomography model, which was composed of female aged magnetic resonance imaging model. The computed tomography + magnetic resonance imaging model, consisting of the first three factors of the computed tomography model, low signal intensity and absence of pseudocapsule on T2-weighted magnetic resonance imaging, re-stratified the tumors into low, intermediate and high angiomyolipoma-probability groups. The incidence of fat-poor angiomyolipoma in each group was 0%, 26% and 93%, respectively (area under the curve 0.981). External validation by two readers showed a high area under the curve (0.912 and 0.924) for each. The interobserver agreement was good (kappa score 0.77). The present algorithm differentiates fat-poor angiomyolipoma in small renal masses with high accuracy by adding magnetic resonance imaging to computed tomography in selected patients. © 2017 The Japanese Urological Association.

  6. Applied CATIA Secondary Development to Parametric Design of Active Magnetic Bearing

    Directory of Open Access Journals (Sweden)

    Zhang Li

    2016-01-01

    Full Text Available Based on the properties of active magnetic bearing, the electromagnetic parameters and structure parameters are analyzed, parametric design method is introduced to study the structure of active magnetic bearing. Through a program personalization process that is in accordance with active magnetic bearing is established. Personalization process aims to build the parametric model of active magnetic bearings and component library by use of CATIA secondary development. Component library is to build assembly model for a multiple degree of freedom magnetic bearing system. Parametric design is a method that provides the direction for its structural design.

  7. Nonlinear vibration behaviors of high-Tc superconducting bulks in an applied permanent magnetic array field

    Science.gov (United States)

    Li, Jipeng; Li, Haitao; Zheng, Jun; Zheng, Botian; Huang, Huan; Deng, Zigang

    2017-06-01

    The nonlinear vibration of high temperature superconducting (HTS) bulks in an applied permanent magnetic array (Halbach array) field, as a precondition for commercial application to HTS maglev train and HTS bearing, is systematically investigated. This article reports the actual vibration rules of HTS bulks from three aspects. First, we propose a new numerical model to simplify the calculation of levitation force. This model could provide precise simulations, especially the estimation of eigenfrequency. Second, an approximate analytic solution of the vibration of the HTS bulks is obtained by using the method of harmonic balance. Finally, to verify the results mentioned above, we measure the vertical vibration acceleration signals of an HTS maglev model, consisting of eight YBaCuO bulks, oscillating freely above a Halbach array with large displacement excitation. Higher order harmonic components, which indicate the nonlinear vibration phenomenon, are detected in the responses. All the three results are compared and agreed well with each other. This study combines the experimental and theoretical analyses and provides a deep understanding of the physical phenomenon of the nonlinear vibration and is meaningful for the vibration control of the relevant applications.

  8. Calcium dependent plasticity applied to repetitive transcranial magnetic stimulation with a neural field model.

    Science.gov (United States)

    Wilson, M T; Fung, P K; Robinson, P A; Shemmell, J; Reynolds, J N J

    2016-08-01

    The calcium dependent plasticity (CaDP) approach to the modeling of synaptic weight change is applied using a neural field approach to realistic repetitive transcranial magnetic stimulation (rTMS) protocols. A spatially-symmetric nonlinear neural field model consisting of populations of excitatory and inhibitory neurons is used. The plasticity between excitatory cell populations is then evaluated using a CaDP approach that incorporates metaplasticity. The direction and size of the plasticity (potentiation or depression) depends on both the amplitude of stimulation and duration of the protocol. The breaks in the inhibitory theta-burst stimulation protocol are crucial to ensuring that the stimulation bursts are potentiating in nature. Tuning the parameters of a spike-timing dependent plasticity (STDP) window with a Monte Carlo approach to maximize agreement between STDP predictions and the CaDP results reproduces a realistically-shaped window with two regions of depression in agreement with the existing literature. Developing understanding of how TMS interacts with cells at a network level may be important for future investigation.

  9. Photothermally modulated magnetic resonance applied to the study of the magnetic phase transition in gadolinium thin films

    Energy Technology Data Exchange (ETDEWEB)

    Soffner, M.E.; Tedesco, J.C.G. [Instituto de Fisica Gleb Wataghin, Universidade Estadual de Campinas (UNICAMP), 13083-859, Campinas, SP (Brazil); Pedrochi, F. [Centro de Ciencias Sociais, Saude e Tecnologia, Universidade Federal do Maranhao, Rua Urbano Santos, s/n, Centro, 65900-000, Imperatriz, MA (Brazil); Gadioli, G.Z.; Moraes, M.A.B. de [Instituto de Fisica Gleb Wataghin, Universidade Estadual de Campinas (UNICAMP), 13083-859, Campinas, SP (Brazil); Guimaraes, A.O.; Silva, E.C. da [Laboratorio de Ciencias Fisicas, Universidade Estadual do Norte Fluminense Darcy Ribeiro, UENF, 28013-602 Campos dos Goytacazes, RJ (Brazil); Mansanares, A.M., E-mail: manoel@ifi.unicamp.br [Instituto de Fisica Gleb Wataghin, Universidade Estadual de Campinas (UNICAMP), 13083-859, Campinas, SP (Brazil)

    2012-02-29

    We explore the photothermally modulated magnetic resonance technique to investigate gadolinium thin films deposited on fused quartz substrate, as a function of thickness and thermal treatment, around the magnetic phase transition temperature. It has been observed that the maximum amplitude of the photothermally modulated magnetic resonance (PM-MR) signal takes place near the phase transition temperature, similarly to the magnetocaloric effect, for which Gd has been the prototype material. The reason is that both depend on the temperature derivative of the magnetization, which maximizes at the phase transition. Besides, there is a narrowing of transition with thermal treatment, confirming that thermal treatment stabilizes the film structure. For frequency scan measurements, the heat diffusion in a two-layer system was considered, and a depth profile study was carried out in order to investigate heterogeneities along the film thickness. From the PM-MR response as a function of the modulation frequency it was possible to estimate the thermal properties of the Gd film. Magnetization, X-ray and electron spin resonance measurements were used to complement the analysis and support the conclusions. - Highlights: Black-Right-Pointing-Pointer TC values increase with thermal treatment and film thickness. Black-Right-Pointing-Pointer PM-MR signal amplitude of the main peak is maximum at temperatures close to TC. Black-Right-Pointing-Pointer Frequency scan showed uniform film profile. Black-Right-Pointing-Pointer Gd film thermal diffusivity was found to be smaller than the bulk one.

  10. Evidence for the ferromagnetic frustration in a classical spin- 1 / 2 system with multisite interaction in external magnetic field: Exact results

    Science.gov (United States)

    Jurčišinová, E.; Jurčišin, M.

    2017-11-01

    We investigate the influence of the multisite interaction among sites within elementary triangles of the kagome-like recursive lattice on the properties of the classical spin- 1 / 2 ferromagnetic Ising model in the external magnetic field. The exact solution of the model is found and it is shown that the model exhibits a nontrivial structure of the first order as well as second order phase transitions in nonzero external magnetic fields related to the multisite interaction. The equation for the exact determination of the positions of the critical points of the second order phase transitions is derived. The thermodynamic properties of the model are investigated in detail and it is shown that the competition between the ferromagnetic interaction and the multisite interaction leads to the appearance of strong ferromagnetic frustration effects represented by the formation of a nontrivial system of macroscopically degenerated plateau-like and single-point-like ground states. The residual entropies of all ground states are found and the kagome spin-ice-like highly macroscopically degenerated plateau state with nonzero magnetization is identified with the exact residual entropy per site s /kB = ln(4 / 3) / 3 ≈ 0 . 095894. The properties of the specific heat are investigated, its Schottky-type behavior near the single-point ground state values of the magnetic field is identified, the existence of large magnetocaloric effect is discussed, and the existence of the first order phase transitions without the specific heat capacity change is demonstrated.

  11. Magnetic resonance techniques applied to the diagnosis and treatment of Parkinson’s disease

    Directory of Open Access Journals (Sweden)

    Benito eDe Celis Alonso

    2015-07-01

    Full Text Available Parkinson’s disease affects at least 10 million people worldwide. It is a neurodegenerative disease which is currently diagnosed by neurological examination. No neuroimaging investigation or blood biomarker is available to aid diagnosis and prognosis. Most effort toward diagnosis using magnetic resonance has been focused on the use of structural/anatomical neuroimaging and diffusion tensor imaging. However, deep brain stimulation, a current strategy for treating Parkinson’s disease, is guided by magnetic resonance imaging. For clinical prognosis, diagnosis and follow-up investigations, blood oxygen level–dependent magnetic resonance imaging, diffusion tensor imaging, spectroscopy and transcranial magnetic stimulation have been used. These techniques represent the state of the art in the last five years. Here, we focus on magnetic resonance techniques for the diagnosis and treatment of Parkinson’s disease.

  12. Comment on "Spin-glass attractor on tridimensional hierarchical lattices in the presence of an external magnetic field".

    Science.gov (United States)

    Berker, A Nihat

    2010-04-01

    The effect of random or uniform magnetic fields on spin glasses on some d=3 hierarchical lattices has been studied, using renormalization-group theory, by Salmon and Nobre. In this work, the recursion relation for the local magnetic field is incorrect. It erroneously weakens the amplitude of the renormalization contribution to the magnetic field by a factor of 1/qmicro, where qmicro is the site coordination number.

  13. An investigation of magnetic field effects on plume density and temperature profiles of an applied-field MPD thruster

    Science.gov (United States)

    Bullock, S. Ray; Myers, R. M.

    1994-01-01

    Applied-field magnetoplasmadynamic (MPD) thruster performance is below levels required for primary propulsion missions. While MPD thruster performance has been found to increase with the magnitude of the applied-field strength, there is currently little understanding of the impact of applied-field shape on thruster performance. The results of a study in which a single applied-field thruster was operated using three solenoidal magnets with diameters of 12.7, 15.2, and 30.4-cm are presented. Thruster voltage and anode power deposition were measured for each applied field shape over a range of field strengths. Plume electron number density and temperature distributions were measured using a Langmuir probe in an effort to determine the effect of field shape on plume confinement by the diverging magnetic-field for each of the three magnetic field shapes. Results show that the dependence of the measured thruster characteristics on field shape were non-monotonic and that the field shape had a significant effect on the plume density and temperature profiles.

  14. Mechanical evaluation of external skeletal fixator-intramedullary pin tie-in configurations applied to cadaveral humeri from red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Van Wettere, Arnaud J; Redig, Patrick T; Wallace, Larry J; Bourgeault, Craig A; Bechtold, Joan E

    2009-12-01

    Use of external skeletal fixator-intramedullary pin (ESF-IM) tie-in fixators is an adjustable and effective method of fracture fixation in birds. The objective of this study was to determine the contribution of each of the following parameters to the compressive and torsional rigidity of an ESF-IM pin tie-in applied to avian bones with an osteotomy gap: (1) varying the fixation pin position in the proximal bone segment and (2) increasing the number of fixation pins in one or both bone segments. ESF-IM pin tie-in constructs were applied to humeri harvested from red-tailed hawks (Buteo jamaicensis) (n=24) that had been euthanatized for clinical reasons. Constructs with a variation in the placement of the proximal fixation pin and with 2, 3, or 4 fixation pins applied to avian bone with an osteotomy gap were loaded to a defined displacement in torque and axial compression. Response variables were determined from resulting load-displacement curves (construct stiffness, load at 1-mm displacement). Increasing the number of fixation pins from 1 to 2 per bone segment significantly increased the stiffness in torque (110%) and compression (60%), and the safe load in torque (107%) and compression (50%). Adding a fixation pin to the distal bone segment to form a 3-pin fixator significantly increased the stiffness (27%) and safe load (20%) in torque but not in axial compression. In the configuration with 2 fixation pins, placing the proximal pin distally in the proximal bone segment significantly increased the stiffness in torque (28%), and the safe load in torque (23%) and in axial compression (32%). Results quantified the relative importance of specific parameters affecting the rigidity of ESF-IM pin tie-in constructs as applied to unstable bone fracture models in birds.

  15. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Science.gov (United States)

    Banerjee, Ananya; Sarkar, A.

    2016-05-01

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  16. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Ananya, E-mail: banerjee.ananya2008@gmail.com; Sarkar, A. [Dept. of Physics, Bijoy Krishna Girls’ College, 5/3 M.G. Road, Howrah 711101, W.B. (India)

    2016-05-06

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  17. Time evolution of the organization of multi-muscle postural responses to sudden changes in the external force applied at the trunk level.

    Science.gov (United States)

    Robert, Thomas; Latash, Mark L

    2008-06-20

    We studied muscle activation patterns in response to perturbations of posture (sudden changes in the external force applied to the thorax) during two time intervals corresponding to pre-programmed postural reactions and voluntary corrections of posture. A hypothesis was tested that a set of postural muscles could be used to form stable groups (M-modes) whose composition changes in different time intervals after a perturbation. Perturbations were applied at the sternum level to standing subjects at an unexpected time. Principal component analysis with factor extraction allowed to identify sets of three factors (M-modes) during the two time intervals, 80-180 ms (T(1)) and 250-450 ms (T(2)) after the perturbation. The composition of M-modes was similar within each time interval across subjects and perturbations but differed significantly between T(1) and T(2). In particular, M-modes during T(1) were characterized by more co-contraction patterns. The results suggest that the neural controller is able to rearrange M-mode composition in real time based on a safety-efficacy trade-off. The results also support the idea that M-modes represent synergies in the muscle space, while they may be used as elemental variables to form synergies at a higher hierarchical level to produce desired mechanical effects.

  18. Self-Focusing and de-Focusing of Intense Left- and Right-Hand Polarized Laser Pulse in Hot Magnetized Plasma in the Presence of an External Non-Uniform Magnetized Field

    Science.gov (United States)

    Abedi-Varaki, Mehdi; Jafari, Saed

    2017-10-01

    In this paper, self-focusing of an intense circularly polarized laser beam in the presence of a non-uniform positive guide magnetic field with slope constant parameter δ in hot magnetized plasma, using Maxwell's equations and relativistic fluid momentum equation is investigated. An envelope equation governing the spot-size of laser beam for both of left- and right-hand polarizations has been derived, and the effects of the plasma temperature and magnetic field on the electron density distribution of hot plasma with respect to variation of normalized laser spot-size has been studied. Numerical results show that self-focusing is better increased in the presence of an external non-uniform magnetic field. Moreover, in plasma density profile, self-focusing of the laser pulse improves in comparison with no non-uniform magnetic field. Also, with increasing slope of constant parameter of the non-uniform magnetic field, the self-focusing increases, and subsequently, the spot-size of laser pulse propagated through the hot magnetized plasma decreases.

  19. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  20. Magnetorotational and Parker instabilities in magnetized plasma Dean flow as applied to centrifugally confined plasmas

    International Nuclear Information System (INIS)

    Huang Yimin; Hassam, A.B.

    2003-01-01

    The ideal magnetohydrodynamics stability of a Dean flow plasma supported against centrifugal forces by an axial magnetic field is studied. Only axisymmetric perturbations are allowed for simplicity. Two distinct but coupled destabilization mechanisms are present: flow shear (magnetorotational instability) and magnetic buoyancy (Parker instability). It is shown that the flow shear alone is likely insufficient to destabilize the plasma, but the magnetic buoyancy instability could occur. For a high Mach number (M S ), high Alfven Mach number (M A ) system with M S M A > or approx. πR/a (R/a is the aspect ratio), the Parker instability is unstable for long axial wavelength modes. Implications for the centrifugal confinement approach to magnetic fusion are also discussed

  1. A novel externally applied neuromuscular stimulator for the treatment of stress urinary incontinence in women--€”a pilot study.

    Science.gov (United States)

    Maher, Ruth M; Caulfield, Brian

    2013-01-01

    €‚ Neuromuscular electrical stimulation (NMES) is commonly used to treat lower urinary tract dysfunctions. This study evaluated the efficacy of a novel externally applied stimulator in the treatment of stress urinary incontinence (SUI). €‚ Nine women were included in this study. Provocative tests included a cough and jumping jack test assessed via pad weight. Ultrasound (US) imaging assessed pelvic floor muscle (PFM) contraction. A bladder filling protocol allowed for delineation of the bladder from the pelvic floor and standardized volume. External electrodes were used during 30 €ƒmin, at least four times per week treatment protocol at home for eight weeks. Participants were blinded to US and were not instructed regarding pelvic floor contractions. €‚ At week 1, participants could perform PFM contractions verified with US. More importantly, an 87.43% decrease in leakage was noted. At week 8, participants reported a 97.71% decrease in leakage (p= 0.0001). Changes noted in Incontinence Impact Questionnaire and Modified Oxford scores were significant (p= 0.0001 and p= 0.0001). €‚ NMES is frequently used to promote muscle strength and coordination. Studies have shown NMES to be effective in decreasing symptoms associated with SUI; however, few, if any, have used it as a primary treatment modality. The novel device in this study was shown to be effective in improving muscle strength, reducing or ablating the symptoms associated with SUI, and in eliciting PFM contractions. The device is noninvasive and can be used as a home treatment. © 2012 International Neuromodulation Society.

  2. Iterative Spherical Downward Continuation Applied to Magnetic and Gravitational Data from Satellite

    Czech Academy of Sciences Publication Activity Database

    Sebera, J.; Šprlák, M.; Novák, P.; Bezděk, Aleš; Valko, M.

    2014-01-01

    Roč. 35, č. 4 (2014), s. 941-958 ISSN 0169-3298 R&D Projects: GA MŠk LH13071 Grant - others:ESA(XE) AO/1-6367/10/NL/AF Institutional support: RVO:67985815 Keywords : downward continuation * Earth's gravitational and magnetic field * poisson integral equation Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 3.447, year: 2014

  3. Magnetic Spin Waves in CsNiF3 with an Applied Field

    DEFF Research Database (Denmark)

    Steiner, M.; Kjems, Jørgen

    1977-01-01

    The spin wave dispersion in the planar 1D ferromagnet CsNiF3 has been measured by inelastic neutron scattering in an external field. The spin wave linewidths are found to decrease with increasing field and become resolution-limited for H>10 kG at 4.2K. At high fields, H>10 kG, both energies...

  4. Effect of Magnetic Flux Density and Applied Current on Temperature, Velocity and Entropy Generation Distributions in MHD Pumps

    Directory of Open Access Journals (Sweden)

    M. Kiyasatfar

    2011-01-01

    Full Text Available In the present study, simulation of steady state, incompressible and fully developed laminar flow has been conducted in a magneto hydrodynamic (MHD pump. The governing equations are solved numerically by finite-difference method. The effect of the magnetic flux density and current on the flow and temperature distributions in a MHD pump is investigated. The obtained results showed that controlling the flow and the temperature is possible through the controlling of the applied current and the magnetic flux. Furthermore, the effects of the magnetic flux density and current on entropy generation in MHD pump are considered. Our presented numerical results are in good agreement with the experimental data showed in literature.

  5. Manipulation of isolated brain nerve terminals by an external magnetic field using D-mannose-coated γ-Fe2O3 nano-sized particles and assessment of their effects on glutamate transport.

    Science.gov (United States)

    Borisova, Tatiana; Krisanova, Natalia; Borуsov, Arsenii; Sivko, Roman; Ostapchenko, Ludmila; Babic, Michal; Horak, Daniel

    2014-01-01

    The manipulation of brain nerve terminals by an external magnetic field promises breakthroughs in nano-neurotechnology. D-Mannose-coated superparamagnetic nanoparticles were synthesized by coprecipitation of Fe(II) and Fe(III) salts followed by oxidation with sodium hypochlorite and addition of D-mannose. Effects of D-mannose-coated superparamagnetic maghemite (γ-Fe2O3) nanoparticles on key characteristics of the glutamatergic neurotransmission were analysed. Using radiolabeled L-[(14)C]glutamate, it was shown that D-mannose-coated γ-Fe2O3 nanoparticles did not affect high-affinity Na(+)-dependent uptake, tonic release and the extracellular level of L-[(14)C]glutamate in isolated rat brain nerve terminals (synaptosomes). Also, the membrane potential of synaptosomes and acidification of synaptic vesicles was not changed as a result of the application of D-mannose-coated γ-Fe2O3 nanoparticles. This was demonstrated with the potential-sensitive fluorescent dye rhodamine 6G and the pH-sensitive dye acridine orange. The study also focused on the analysis of the potential use of these nanoparticles for manipulation of nerve terminals by an external magnetic field. It was shown that more than 84.3 ± 5.0% of L-[(14)C]glutamate-loaded synaptosomes (1 mg of protein/mL) incubated for 5 min with D-mannose-coated γ-Fe2O3 nanoparticles (250 µg/mL) moved to an area, in which the magnet (250 mT, gradient 5.5 Т/m) was applied compared to 33.5 ± 3.0% of the control and 48.6 ± 3.0% of samples that were treated with uncoated nanoparticles. Therefore, isolated brain nerve terminals can be easily manipulated by an external magnetic field using D-mannose-coated γ-Fe2O3 nanoparticles, while the key characteristics of glutamatergic neurotransmission are not affected. In other words, functionally active synaptosomes labeled with D-mannose-coated γ-Fe2O3 nanoparticles were obtained.

  6. Spin wave spectrum in CeRhIn5 under applied magnetic fields

    Science.gov (United States)

    Fobes, David; Lin, S.-Z.; Ghimire, N. J.; Ronning, F.; Bauer, E. D.; Thompson, J. D.; Batista, C. D.; Ehlers, G.; Janoschek, M.

    The phase diagram of CeRhIn5 is in many ways a prototypical example of a heavy fermion superconductor; it is a heavy fermion antiferromagnet that can be tuned to a quantum critical point (QCP) via pressure, around which unconventional superconductivity emerges. Closer inspection reveals unusual behavior however; the interplay between magnetism and unconventional superconductivity is atypical, and electrical transport behavior and changes in the Fermi surface at the QCP are not in agreement with the prototypical spin-density-wave-type scenario. This is supported by our previous measurements of the spin wave spectrum at ambient pressure replicated by a simple frustrated J1 -J2 model based on localized Ce 4 f electrons. We show that the addition of magnetic anisotropy and Zeeman terms to our Anisotropic Next-Nearest Neighbor Ising (ANNNI) model Hamiltonian quantitatively describes the spin wave spectrum under the application of magnetic field as obtained by neutron scattering, and reproduces the experimental magnetic phase diagram. Finally, this model predicts that the magnetic ordering vector should change logarithmically as a function of temperature across the high-field incommensurate-to-commensurate phase boundary, in agreement with our latest neutron diffraction results.

  7. The effect of external magnetic field on mark size in heat-assisted probe recording on CoNi/Pt multilayers

    NARCIS (Netherlands)

    Zhang, Li; Bain, James A.; Zhu, Jian-Gang; Abelmann, Leon; Onoue, T.

    A method of heat-assisted magnetic recording potentially suitable for probe-based storage systems is characterized. In this work, field-emission current from a scanning tunneling microscope tip isused as the heating source. Pulse voltages of 2-7 V were applied to a CoNi/Pt multilayered film. During

  8. Head-on collision of dust-acoustic solitary waves in an adiabatic hot dusty plasma with external oblique magnetic field and two-temperature ions

    Science.gov (United States)

    El-Labany, S. K.; El-Shamy, E. F.; Sabry, R.; Shokry, M.

    2010-02-01

    In the present paper, the characteristics of the head-on collision between two dust-acoustic solitary waves (DASWs) in an adiabatic dusty plasma consisting of variable negatively charged dust grains, isothermal electrons and two-temperature isothermal ions in the presence of an external oblique magnetic field are investigated. Using the extended Poincaré-Lighthill-Kuo (PLK) method, the Korteweg-de Vries (KdV) equations and the analytical phase shifts after the head-on collision of two solitary waves are derived. The effects of the magnetic field and its obliqueness, two different type of isothermal ions and the dust particles adiabaticity are discussed. It is found that these factors significantly affect the phase shifts.

  9. Magnetic and viscoelastic response of elastomers with hard magnetic filler

    International Nuclear Information System (INIS)

    Kramarenko, E Yu; Chertovich, A V; Semisalova, A S; Makarova, L A; Perov, N S; Khokhlov, A R; Stepanov, G V

    2015-01-01

    Magnetic elastomers (MEs) based on a silicone matrix and magnetically hard NdFeB particles have been synthesized and their magnetic and viscoelastic properties have been studied depending on the size and concentration of magnetic particles and the magnetizing field. It has been shown that magnetic particles can rotate in soft polymer matrix under applied magnetic field, this fact leading to some features in both magnetic and viscoelastic properties. In the maximum magnetic field used magnetization of MEs with smaller particles is larger while the coercivity is smaller due to higher mobility of the particles within the polymer matrix. Viscoelastic behavior is characterized by long relaxation times due to restructuring of the magnetic filler under the influence of an applied mechanical force and magnetic interactions. The storage and loss moduli of magnetically hard elastomers grow significantly with magnetizing field. The magnetic response of the magnetized samples depends on the mutual orientation of the external magnetic field and the internal sample magnetization. Due to the particle rotation within the polymer matrix, the loss factor increases abruptly when the magnetic field is turned on in the opposite direction to the sample magnetization, further decreasing with time. Moduli versus field dependences have minimum at non-zero field and are characterized by a high asymmetry with respect to the field direction. (paper)

  10. Controlling magnetism of MoS2 sheets by embedding transition-metal atoms and applying strain.

    Science.gov (United States)

    Zhou, Yungang; Su, Qiulei; Wang, Zhiguo; Deng, Huiqiu; Zu, Xiaotao

    2013-11-14

    Prompted by recent experimental achievement of transition metal (TM) atoms substituted in MoS2 nanostructures during growth or saturating existing vacancies (Sun et al., ACS Nano, 2013, 7, 3506; Deepak et al., J. Am. Chem. Soc., 2007, 129, 12549), we explored, via density functional theory, the magnetic properties of a series of 3d TM atoms substituted in a MoS2 sheet, and found that Mn, Fe, Co, Ni, Cu and Zn substitutions can induce magnetism in the MoS2 sheet. The localizing unpaired 3d electrons of TM atoms respond to the introduction of a magnetic moment. Depending on the species of TM atoms, the substituted MoS2 sheet can be a metal, semiconductor or half-metal. Remarkably, the applied elastic strain can be used to control the strength of the spin-splitting of TM-3d orbitals, leading to an effective manipulation of the magnetism of the TM-substituted MoS2 sheet. We found that the magnetic moment of the Mn- and Fe-substituted MoS2 sheets can monotonously increase with the increase of tensile strain, while the magnetic moment of Co-, Ni-, Cu- and Zn-substituted MoS2 sheets initially increases and then decreases with the increase of tensile strain. An instructive mechanism was proposed to qualitatively explain the variation of magnetism with elastic strain. The finding of the magnetoelastic effect here is technologically important for the fabrication of strain-driven spin devices on MoS2 nanostructures, which allows us to go beyond the current scope limited to the spin devices within graphene and BN-based nanostructures.

  11. A RBFNN-Based Adaptive Disturbance Compensation Approach Applied to Magnetic Suspension Inertially Stabilized Platform

    Directory of Open Access Journals (Sweden)

    Quanqi Mu

    2014-01-01

    Full Text Available Compared with traditional mechanical inertially stabilized platform (ISP, magnetic suspension ISP (MSISP can absorb high frequency vibrations via a magnetic suspension bearing system with five degrees of freedom between azimuth and pitch gimbals. However, force acting between rotor and stator will introduce coupling torque to roll and pitch gimbals. Since the disturbance of magnetic bearings has strong nonlinearity, classic state feedback control algorithm cannot bring higher precision control for MSISP. In order to enhance the control accuracy for MSISP, a disturbance compensator based on radial basis function neural network (RBFNN is developed to compensate for the disturbance. Using the Lyapunov theorem, the weighting matrix of RBFNN can be updated online. Therefore, the RBFNN can be constructed without priori training. At last, simulations and experiment results validate that the compensation method proposed in this paper can improve ISP accuracy significantly.

  12. Effect of an applied magnetic field on the performance of a SIS receiver near 300 GHz

    Science.gov (United States)

    Mallison, W. H.; De Zafra, R. L.

    1992-01-01

    A superconductor-insulator-superconductor (SIS) receiver has been successfully constructed and tested for operation at 265 - 280 GHz using 1 micron/sq area Nb-AlO(x)-Nb tunnel junctions fabricated at Stony Brook. The best performance to date is a double sideband (DSB) receiver noise temperature of 129 K at 278 GHz. It is found that suppression of the Josephson pair currents with a magnetic field is essential for good performance and a stable dc bias point. Fields as high as 280 gauss have been used with no degradation of mixing performance. The improvement in the intermediate frequency output stability with progressively increasing magnetic fields is illustrated.

  13. Regional Externalities

    NARCIS (Netherlands)

    Heijman, W.J.M.

    2007-01-01

    The book offers practical and theoretical insights in regional externalities. Regional externalities are a specific subset of externalities that can be defined as externalities where space plays a dominant role. This class of externalities can be divided into three categories: (1) externalities

  14. Dynamic phase transitions of the Blume–Emery–Griffiths model under an oscillating external magnetic field by the path probability method

    Energy Technology Data Exchange (ETDEWEB)

    Ertaş, Mehmet, E-mail: mehmetertas@erciyes.edu.tr; Keskin, Mustafa

    2015-03-01

    By using the path probability method (PPM) with point distribution, we study the dynamic phase transitions (DPTs) in the Blume–Emery–Griffiths (BEG) model under an oscillating external magnetic field. The phases in the model are obtained by solving the dynamic equations for the average order parameters and a disordered phase, ordered phase and four mixed phases are found. We also investigate the thermal behavior of the dynamic order parameters to analyze the nature dynamic transitions as well as to obtain the DPT temperatures. The dynamic phase diagrams are presented in three different planes in which exhibit the dynamic tricritical point, double critical end point, critical end point, quadrupole point, triple point as well as the reentrant behavior, strongly depending on the values of the system parameters. We compare and discuss the dynamic phase diagrams with dynamic phase diagrams that were obtained within the Glauber-type stochastic dynamics based on the mean-field theory. - Highlights: • Dynamic magnetic behavior of the Blume–Emery–Griffiths system is investigated by using the path probability method. • The time variations of average magnetizations are studied to find the phases. • The temperature dependence of the dynamic magnetizations is investigated to obtain the dynamic phase transition points. • We compare and discuss the dynamic phase diagrams with dynamic phase diagrams that were obtained within the Glauber-type stochastic dynamics based on the mean-field theory.

  15. Applied metrology in the production of superconducting model magnets for particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ferradas Troitino, Jose [CERN; Bestmann, Patrick [CERN; Bourcey, Nicolas [CERN; Carlon Zurita, Alejandro [CERN; Cavanna, Eugenio [ASG Supercond., Genova; Ferracin, Paolo [CERN; Ferradas Troitino, Salvador [CERN; Holik, Eddie Frank [Fermilab; Izquierdo Bermudez, Susana [CERN; Lackner, Friedrich [CERN; Löffler, Christian [CERN; Maury, Gregory [CERN; Perez, Juan Carlos [CERN; Savary, Frederic [CERN; Semeraro, Michela [CERN; Vallone, Giorgio [CERN

    2017-12-22

    The production of superconducting magnets for particle accelerators involves high precision assemblies and tight tolerances, in order to achieve the requirements for their appropriate performance. It is therefore essential to have a strict control and traceability over the geometry of each component of the system, and also to be able to compensate possible inherent deviations coming from the production process.

  16. Ab initio screening methodology applied to the search for new permanent magnetic materials

    International Nuclear Information System (INIS)

    Drebov, Nedko; Gumbsch, Peter; Elsässer, Christian; Martinez-Limia, Alberto; Kunz, Lothar; Gola, Adrien; Eckl, Thomas; Shigematsu, Takashi

    2013-01-01

    In this paper a computational high-throughput screening (HTS) approach to the search for alternative permanent magnetic materials is presented. Systems considered for a start are binary intermetallic compounds composed of rare-earth (RE) and transition metal (TM) elements. With the tight-binding-linear muffin-tin-orbital-atomic-sphere-approximation (TB-LMTO-ASA) method of density functional theory (DFT) a variety of RE–TM intermetallic phases is investigated and their magnetic properties are obtained at rather low computational costs. Next, interstitial elements such as boron, carbon and nitrogen in these phases are considered. For promising candidate phases with high and stable spontaneous ferromagnetic polarization, the calculated local magnetic moments and exchange coupling parameters, as obtained from TB-LMTO-ASA calculations, are then used for Monte Carlo simulations to identify candidates with sufficiently high Curie temperatures (T c ). Finally, magnetocrystalline anisotropy constants (K 1 ) of the most promising candidate phases are calculated with accurate, potential-shape-unrestricted DFT calculations using the Vienna ab initio simulation package. The computational HTS procedure is illustrated by results for a selection of hard-magnetic RE–TM phases like RETM 5 , RE 2 TM 17 and RE 2 TM 14 B. (paper)

  17. An experimental comparison of path planning techniques applied to micro-sized magnetic agents

    NARCIS (Netherlands)

    Scheggi, Stefano; Misra, Sarthak; Haliyo, S.; Sill, A.; Regnier, S.; Fatikow, S.

    2016-01-01

    Micro-sized agents can be used in applications suchas microassembly, micromanipulation, and minimally invasive surgeries. Magnetic agents such as paramagnetic microparticles can be controlled to deliver pharmaceutical agents to difficult-toaccess regions within the human body. In order to

  18. A novel Planar Magnetic Bearing and Motor Configuration applied in a Positioning Stage

    NARCIS (Netherlands)

    Molenaar, A.

    2000-01-01

    This thesis presents the design and implementation of a fully contactless high precision magnetically suspended position stage with large planar stroke. This stage is the first which is suitable for practical application in vacuum. The underlying electromechanical working principles, modelling and

  19. Energy Moment Method Applied to Nuclear Quadrupole Splitting of Nuclear Magnetic Resonance Lines

    DEFF Research Database (Denmark)

    Frank, V

    1962-01-01

    Expressions giving the sum of the energy values, raised to the second and third power, for a nucleus interacting with a static magnetic field and a static electric field gradient are derived. Several applications of this method for obtaining the values of the components of the electric field...

  20. Heat generation of surface-modified magnetic γ-Fe2O3 nanoparticles in applied alternating magnetic field

    Science.gov (United States)

    Babič, Michal; Horák, Daniel; Molčan, Matúš; Timko, Milan

    2017-08-01

    In this report, we show preparation of colloidally stable poly(N,N-dimethylacrylamide-co-acrylic acid) (DMA)- and D-mannose (MAN)-coated maghemite nanoparticles and their ability to generate heat in an alternating magnetic field, which could make the particles applicable for hyperthermic therapy of cancer. The particles are obtained by coprecipitation reaction and characterized by transmission electron microscopy, dynamic light scattering, and AC calorimetric measurement of heat generated by the particles. While the dry particles were ca. 10 nm in diameter, their hydrodynamic size in water was within the range of 100 nm. Heating characteristics were measured in an LC circuit with a maximum field intensity of 6.8 kA · m-1 and frequency 190 kHz. The specific absorption rates of γ-Fe2O3, PDM@γ-Fe2O3, and MAN@γ-Fe2O3 nanoparticles were extrapolated to 10 kA · m-1, reaching about 15 W · g-1.

  1. Proposal for the award of a contract for the supply of the external cryogenic sub-system for the magnets of the ATLAS experiment

    CERN Document Server

    2001-01-01

    This document concerns the award of a contract for the supply, including design, installation, commissioning and testing at CERN of the external cryogenic sub-system for the magnets of the ATLAS experiment. Following a market survey carried out among 28 firms in eight Member States and eight firms in two non-Member States, a call for tenders (IT-2807/EP/ATLAS) was sent on 17 August 2000 to two firms in two Member States. By the closing date, CERN had received tenders from the two firms. The Finance Committee is invited to agree to the negotiation of a contract with LINDE KRYOTECHNIK (CH), the lowest bidder, for the design, supply, installation, commissioning and testing at CERN of the external cryogenic sub-system for the magnets of the ATLAS experiment for a total amount of 6 652 000 Swiss francs, not subject to revision, with options for interconnecting low- and high-pressure warm piping and for spare parts, for an additional amount of 910 170 Swiss francs, not subject to revision, bringing the total amount...

  2. Urban runoff treatment using nano-sized iron oxide coated sand with and without magnetic field applying.

    Science.gov (United States)

    Khiadani Hajian, Mehdi; Zarrabi, Mansur; Foroughi, Maryam

    2013-12-20

    Increase of impervious surfaces in urban area followed with increases in runoff volume and peak flow, leads to increase in urban storm water pollution. The polluted runoff has many adverse impacts on human life and environment. For that reason, the aim of this study was to investigate the efficiency of nano iron oxide coated sand with and without magnetic field in treatment of urban runoff. In present work, synthetic urban runoff was treated in continuous separate columns system which was filled with nano iron oxide coated sand with and without magnetic field. Several experimental parameters such as heavy metals, turbidity, pH, nitrate and phosphate were controlled for investigate of system efficiency. The prepared column materials were characterized with Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray analysis (EDXA) instruments. SEM and EDXA analyses proved that the sand has been coated with nano iron oxide (Fe3O4) successfully. The results of SEM and EDXA instruments well demonstrate the formation of nano iron oxide (Fe3O4) on sand particle. Removal efficiency without magnetic field for turbidity; Pb, Zn, Cd and PO4 were observed to be 90.8%, 73.3%, 75.8%, 85.6% and 67.5%, respectively. When magnetic field was applied, the removal efficiency for turbidity, Pb, Zn, Cd and PO4 was increased to 95.7%, 89.5%, 79.9%, 91.5% and 75.6% respectively. In addition, it was observed that coated sand and magnetic field was not able to remove NO3 ions. Statistical analyses of data indicated that there was a significant difference between removals of pollutants in two tested columns. Results of this study well demonstrate the efficiency of nanosized iron oxide-coated sand in treatment of urban runoff quality; upon 75% of pollutants could be removed. In addition, in the case of magnetic field system efficiency can be improved significantly.

  3. Parameters and definitions in applied technique quality test for nuclear magnetic resonance imaging system (NMRI)

    International Nuclear Information System (INIS)

    Lin Zhikai; Zhao Lancai

    1999-08-01

    During the past two decades, medical diagnostic imaging technique has achieved dramatic development such as CT, MRI, PET, DSA and so on. The most striking examples of them are the application of X ray computerized tomography (CT) and magnetic resonance imaging in the field of medical diagnosis. It can be predicted that magnetic resonance imaging (MRI) will definitely have more widespread prospects of applications and play more and more important role in clinical diagnosis looking forward to the development of image diagnostic technique for 21 st century. The authors also present the measuring methods for some parameters. The parameters described can be used for reference by clinical diagnosticians, operators on MRI and medical physicists who engages in image quality assurance (QA) and control (QC) in performing MRI acceptance test and routine test

  4. Damping of Solute Convection During Crystal Growth by Applying Magnetic Field Gradients

    Science.gov (United States)

    Wakayama, Nobuko I.

    2005-06-01

    One of the advantages of crystal growth under microgravity conditions is the damping of solute convection that affects crystal quality. The mechanism of the dampening effect of magnetic field gradients, B(dB/dz), on solute convection was studied, and the magnitude of B(dB/dz) required for dampening was calculated. When the absolute value of mass magnetic susceptibility, χg, of a solute is about 70% of that of a solvent (e.g., KCl crystal growth from an aqueous solution) and the weight ratio is 0.26, the gradient to damp convection considerably is estimated to be -3018 T2/m. On the other hand, when the χg of the solute is nearly equal to that of the solvent [protein crystal growth (lysozyme)], a gradient of -1394 T2/m damps convection completely on the earth.

  5. Lagrangian neoclassical transport theory applied to the region near the magnetic axis

    Energy Technology Data Exchange (ETDEWEB)

    Satake, Shinsuke [The Graduate Univ. for Advanced Studies, Dept. of Fusion Science, Toki, Gifu (Japan); Okamoto, Masao; Sugama, Hideo [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2002-06-01

    Neoclassical transport theory around the magnetic axis of a tokamak is studied, in which relatively wide ''potato'' orbits play an important role in transport. Lagrangian formulation of transport theory, which has been investigated to reflect finiteness of guiding-center orbit widths to transport equations, is developed in order to analyze neoclassical transport near the axis for a low-collisionality plasma. The treatment of self-collision term in Lagrangian formulation is revised to retain momentum conservation property of it. With directly reflecting the orbital properties of all the types of orbits in calculation, the ion thermal conductivity around the axis is found to decrease than from that predicted by conventional neoclassical theory. This result supports recent numerical simulations which show the reduction of thermal conductivity near the magnetic axis. (author)

  6. S100 lathe bed pulse generator applied to pulsed nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cernicchiaro, G.R.C.; Rudge, M.G.; Albuquerque, M.P.

    1989-01-01

    The project and construction of four channel pulse generator in the S100 standard plate and its control software for microcomputer are described. The microcomputer has total control on the pulse generator, which has seven programable parameters, defining the position of four pulses and the width for the three first ones. This pulse generator is controlled by a software developed in c language, and is used in pulsed nuclear magnetic resonance experiences. (M.C.K.) [pt

  7. Ferrofluid spiral formations and continuous-to-discrete phase transitions under simultaneously applied DC axial and AC in-plane rotating magnetic fields

    International Nuclear Information System (INIS)

    Rhodes, Scott; Perez, Juan; Elborai, Shihab; Lee, Se-Hee; Zahn, Markus

    2005-01-01

    New flows and instabilities are presented for a ferrofluid drop contained in glass Hele-Shaw cells with simultaneously applied in-plane clockwise rotating and DC axial uniform magnetic fields. When a ferrofluid drop is stressed by a uniform DC axial magnetic field, up to ∼250 G in 0.9-1.4 mm gap Hele-Shaw cells, the drop forms a labyrinth pattern. With subsequent application of an in-plane uniform rotating magnetic field, up to ∼100 G rms at frequency 20-40 Hz, smooth spirals form from viscous shear due to ferrofluid flow. If the rotating magnetic field is applied first, the drop is held together without a labyrinth. Gradual increase of the DC axial magnetic field, to a critical magnetic field value, results in an abrupt phase transformation from a large drop to many small discrete droplets. A preliminary minimum magnetization and surface energy analysis is presented to model the phase transformation

  8. Flow of liquid metals in curved channels under a transversely applied magnetic field, (3)

    International Nuclear Information System (INIS)

    Arai, Shigeki; Tomita, Yukio; Sudou, Kouzou.

    1979-01-01

    With the development of electromagnetic pumps in nuclear, metallurgical and casting industries, investigations of not only laminar flow but also transient and turbulent flows in magnetohydrodynamic (MHD) channels are the matters of much concern. However, it is no exaggeration to say that there was no investigation of transient and turbulent flows in curved MHD channels. In this report, the influences of Reynolds number, Hartmann number, radius of curvature and aspect ratio on the coefficient of friction in transient and turbulent flow channels are discussed. In transient flow region, the curve representing the product of the coefficient of channel friction in curved channels and Reynolds number has no clear transition point in the flow of comparatively small Hartmann number. However, as the intensity of magnetic field is increased, the curve transfers to the transition due to the effect of suppressing secondary flow, and if the magnetic field is further increased, it was found that it approached the crisis-free type transition. In turbulent flow region, the coefficient of channel friction can be expressed approximately by the empirical equation given first in this report. Also the effect of magnetic field on the turbulent flow in curved channels can be explained by using Hartmann effect, turbulence suppression effect, and the effect of suppressing secondary flow based on Lorentz's force. (Wakatsuki, Y.)

  9. A deterministic solution of the first order linear Boltzmann transport equation in the presence of external magnetic fields.

    Science.gov (United States)

    St Aubin, J; Keyvanloo, A; Vassiliev, O; Fallone, B G

    2015-02-01

    Accurate radiotherapy dose calculation algorithms are essential to any successful radiotherapy program, considering the high level of dose conformity and modulation in many of today's treatment plans. As technology continues to progress, such as is the case with novel MRI-guided radiotherapy systems, the necessity for dose calculation algorithms to accurately predict delivered dose in increasingly challenging scenarios is vital. To this end, a novel deterministic solution has been developed to the first order linear Boltzmann transport equation which accurately calculates x-ray based radiotherapy doses in the presence of magnetic fields. The deterministic formalism discussed here with the inclusion of magnetic fields is outlined mathematically using a discrete ordinates angular discretization in an attempt to leverage existing deterministic codes. It is compared against the EGSnrc Monte Carlo code, utilizing the emf_macros addition which calculates the effects of electromagnetic fields. This comparison is performed in an inhomogeneous phantom that was designed to present a challenging calculation for deterministic calculations in 0, 0.6, and 3 T magnetic fields oriented parallel and perpendicular to the radiation beam. The accuracy of the formalism discussed here against Monte Carlo was evaluated with a gamma comparison using a standard 2%/2 mm and a more stringent 1%/1 mm criterion for a standard reference 10 × 10 cm(2) field as well as a smaller 2 × 2 cm(2) field. Greater than 99.8% (94.8%) of all points analyzed passed a 2%/2 mm (1%/1 mm) gamma criterion for all magnetic field strengths and orientations investigated. All dosimetric changes resulting from the inclusion of magnetic fields were accurately calculated using the deterministic formalism. However, despite the algorithm's high degree of accuracy, it is noticed that this formalism was not unconditionally stable using a discrete ordinate angular discretization. The feasibility of including magnetic field

  10. The effects of self-generated and applied magnetic fields on the computation of flow over a Mars return aerobrake

    Science.gov (United States)

    Palmer, Grant

    1991-01-01

    A CFD technique is developed to calculate the electromagnetic phenomena simultaneously with the fluid flow in the shock layer over an axisymmetric blunt body in a thermal-equilibrium chemical-nonequilibrium environment. The flowfield is solved using an explicit time-marching, first-order spatially accurate scheme. The electromagnetic phenomena are coupled to the real-gas flow solver through an iterative procedure. The electromagnetic terms introduce a strong stiffness, which was overcome by using significantly smaller time steps for the electromagnetic conservation equation. The technique is applied in calculating the flow over a Mars return aerobrake vehicle entering the Earth's atmosphere. For the case where no external field is applied, the electromagnetic effects have little impact on the flowfield.

  11. ANOMALIES IN THE APPLIED MAGNETIC FIELDS ON DIII-D AND THEIR IMPLICATIONS FOR THE UNDERSTANDING OF STABILITY EXPERIMENTS

    International Nuclear Information System (INIS)

    LUXON, J.L; SCHAFFER, M.J; JACKSON, G.L; LEUER, J.A; NAGY, A; SCOVILLE, J.T; STRAIT, E.J

    2003-01-01

    Small non-axisymmetric magnetic fields are known to cause serious loss of stability in tokamaks leading to loss of confinement and abrupt termination of plasma current (disruptions). The best known examples are the locked mode and the resistive wall mode. Understanding of the underlying field anomalies (departures in the hardware-related fields from ideal toroidal and poloidal fields on a single axis) and the interaction of the plasma with them is crucial to tokamak development. Results of both locked mode experiments and resistive wall mode experiments done in DIII-D tokamak plasmas have been interpreted to indicate the presence of a significant anomalous field. New measurements of the magnetic field anomalies of the hardware systems have been made on DIII-D. The measured field anomalies due to the plasma shaping coils in DIII-D are smaller than previously reported. Additional evaluations of systematic errors have been made. New measurements of the anomalous fields of the ohmic heating and toroidal coils have been added. Such detailed in situ measurements of the fields of a tokamak are unique. The anomalous fields from all of the coils are one third of the values indicated from the stability experiments. These results indicate limitations in the understanding of the interaction of the plasma with the external field. They indicate that it may not be possible to deduce the anomalous fields in a tokamak from plasma experiments and that we may not have the basis needed to project the error field requirements of future tokamaks

  12. Anomalies in the applied magnetic fields in DIII-D and their implications for the understanding of stability experiments

    Energy Technology Data Exchange (ETDEWEB)

    Luxon, J. L.; Schaffer, M. J.; Jackson, G. L.; Leuer, J. A.; Nagy, A.; Scoville, J. T.; Strait, E. J.

    2003-12-01

    Small non-axisymmetric magnetic fields are known to cause serious loss of stability in tokamaks leading to loss of confinement and abrupt termination of plasma current (disruptions). The best known examples are the locked mode and the resistive wall mode. Understanding of the underlying field anomalies (departures in the hardware-related fields from ideal toroidal and poloidal fields on a single axis) and the interaction of the plasma with them is crucial to tokamak development. Results of both locked mode experiments and resistive wall mode experiments done in DIII-D tokamak plasmas have been interpreted to indicate the presence of a significant anomalous field. New measurements of the magnetic field anomalies of the hardware systems have been made on DIII-D. The measured field anomalies due to the plasma shaping coils in DIII-D are smaller than previously reported. Additional evaluations of systematic errors have been made. New measurements of the anomalous fields of the ohmic heating and toroidal coils have been added. Such detailed in situ measurements of the fields of a tokamak are unique. The anomalous fields from all of the coils are one third of the values indicated from the stability experiments. These results indicate limitations in the understanding of the interaction of the plasma with the external field. They indicate that it may not be possible to deduce the anomalous fields in a tokamak from plasma experiments and that we may not have the basis needed to project the error field requirements of future tokamaks.

  13. NUMERICAL MODELING THE INTERACTION OF A MAGNETIC FIELD WITH A CYLINDRICAL MAGNETIC FLUID LAYER

    Directory of Open Access Journals (Sweden)

    V. K. Polevikov

    2017-01-01

    Full Text Available A combined method of finite differences and boundary elements is applied to solve a nonlinear conjugate problem of magnetostatics describing, the interaction of a uniform magnetic field with a cylindrical magnetic fluid layer. Magnetic permeability of the fluid is considered to be a non-linearly dependent on the magnetic field intensity. Shielding properties of a cylindrical thick-walled magneticfluid layer, depending on the external magnetic field intensity, are investigated. A shielding effectiveness factor is calculated.

  14. Relativistic dynamics of an electron in a pulse of laser light with propagation along of an external magnetic field

    International Nuclear Information System (INIS)

    Gomez, F.; Ondarza, R.

    2003-01-01

    The exact solution for the movement of a charged particle in the interaction of an electromagnetic pulse elliptically polarized spreading along a static and homogeneous magnetic field is obtained starting from the equation of force. The solution method allows to solve, in terms of the phase, the trajectory of an accelerated particle by a pulse of arbitrary width and modulated by an encircling in Gaussian form. The reported solutions in this work have diverse applications in the laser-plasma interaction physics. (Author)

  15. Effect of rotation on peristaltic flow of a micropolar fluid through a porous medium with an external magnetic field

    International Nuclear Information System (INIS)

    Abd-Alla, A.M.; Abo-Dahab, S.M.; Al-Simery, R.D.

    2013-01-01

    In this paper, the effects of both rotation and magnetic field of a micropolar fluid through a porous medium induced by sinusoidal peristaltic waves traveling down the channel walls are studied analytically and computed numerically. Closed-form solutions under the consideration of long wavelength and low-Reynolds number is presented. The analytical expressions for axial velocity, pressure rise per wavelength, mechanical efficiency, spin velocity, stream function and pressure gradient are obtained in the physical domain. The effect of the rotation, density, Hartmann number, permeability, coupling number, micropolar parameter and the non-dimensional wave amplitude in the wave frame is analyzed theoretically and computed numerically. Numerical results are given and illustrated graphically in each case considered. Comparison was made with the results obtained in the presence and absence of rotation and magnetic field. The results indicate that the effect of rotation, density, Hartmann number, permeability, coupling number, micropolar parameter and the non-dimensional wave amplitude are very pronounced in the phenomena. - Highlights: • The effects of induced magnetic field and rotation in peristaltic motion of a two dimensional of a micropolar fluid through a porous medium • The exact and closed form solutions are presented • Different wave shapes are considered to observe the behavior of the axial velocity, pressure rise, mechanical efficiency, spin velocity, stream function and pressure gradient

  16. Effect of rotation on peristaltic flow of a micropolar fluid through a porous medium with an external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Abd-Alla, A.M., E-mail: mohmrr@yahoo.com [Maths Department, Faculty of Science, Taif University (Saudi Arabia); Abo-Dahab, S.M., E-mail: sdahb@yahoo.com [Maths Department, Faculty of Science, Taif University (Saudi Arabia); Maths Department, Faculty of Science, SVU, Qena 83523 (Egypt); Al-Simery, R.D. [Maths Department, Faculty of Science, Taif University (Saudi Arabia)

    2013-12-15

    In this paper, the effects of both rotation and magnetic field of a micropolar fluid through a porous medium induced by sinusoidal peristaltic waves traveling down the channel walls are studied analytically and computed numerically. Closed-form solutions under the consideration of long wavelength and low-Reynolds number is presented. The analytical expressions for axial velocity, pressure rise per wavelength, mechanical efficiency, spin velocity, stream function and pressure gradient are obtained in the physical domain. The effect of the rotation, density, Hartmann number, permeability, coupling number, micropolar parameter and the non-dimensional wave amplitude in the wave frame is analyzed theoretically and computed numerically. Numerical results are given and illustrated graphically in each case considered. Comparison was made with the results obtained in the presence and absence of rotation and magnetic field. The results indicate that the effect of rotation, density, Hartmann number, permeability, coupling number, micropolar parameter and the non-dimensional wave amplitude are very pronounced in the phenomena. - Highlights: • The effects of induced magnetic field and rotation in peristaltic motion of a two dimensional of a micropolar fluid through a porous medium • The exact and closed form solutions are presented • Different wave shapes are considered to observe the behavior of the axial velocity, pressure rise, mechanical efficiency, spin velocity, stream function and pressure gradient.

  17. Quality Control Techniques Applied to the Large Scale Production of Superconducting Dipole Magnets for LHC

    CERN Document Server

    Savary, F; Beauquis, J; Emelianenko, N; Fessia, P; Hagen, P; Miles, J; de Rijk, G; Rossi, L; Todesco, E; Vlogaert, J; Völlinger, C; Wildner, E

    2006-01-01

    The LHC accelerator, under construction at CERN, is characterized by the use on a large scale of high field superconducting dipoles: the 27-km ring requires 1232 15-m long dipole magnets designed for a peak field of 9 T. The coils are wound with Rutherford-type cable based on copper-stabilized Nb-Ti superconductors and will be operated at 1.9 K in pressurized superfluid helium. The challenge that had to be faced has been an efficient, cost-effective and reproducible mass production to very tight tolerances: the field quality must be better than 10-4 and the geometry of the cold bore tube and magnet controlled to 0.1 mm over the whole length, any deviation being liable to induce delays and significant cost increase. This paper presents the main methods and tools chosen to face successfully this challenge: some methods were foreseen in the technical specification, others were implemented based on the experience gained in several years of fabrication.

  18. Measurement of the intersystem crossing rate in aluminum tris(8-hydroxyquinoline) and its modulation by an applied magnetic field

    Science.gov (United States)

    Zhang, Sijie; Song, Jingyao; Kreouzis, T.; Gillin, W. P.

    2009-08-01

    The rate constant for intersystem crossing in aluminum tris(8-hydroxyquinoline) was measured using the time dependence of the luminescence under high excitation intensity and modeling using a rate equation approach. Under high illumination levels intersystem crossing results in the transfer of singlets into triplets, which due to their long lifetime effectively remove molecules from participating in photoluminescence. The intersystem crossing rate was found to be ˜2.2×104 s-1 at 80 K. The presence of a magnetic field was found to increase the rate constant by ˜10% with applied fields of ˜100 mT.

  19. Temperature Development on the External Root Surface During Laser-Assisted Endodontic Treatment Applying a Microchopped Mode of a 980 nm Diode Laser.

    Science.gov (United States)

    Beer, Franziska; Farmakis, Eleftherios Terry R; Kopic, Josip; Kurzmann, Christoph; Moritz, Andreas

    2017-04-01

    The aim of this article was to investigate the temperature increase of the external root surface during laser-assisted endodontic treatment using a diode laser (980 nm) in a microchopped mode. Ten freshly extracted, human maxillary incisors with mature apices were collected, prepared to size F4 at working length (ProTaper; Dentsply Maillefer, Ballaigues, Switzerland), mounted to a holder, and irradiated (using spiral movements in coronal direction) with a diode laser (GENTLEray 980 Classic Plus; KaVo, Biberach, Germany) with a 200 μm fiber in four different treatment groups: Group 1 (control group) was irradiated in six cycles of 5-sec irradiation/20-sec pause with 2.5 W in the pulse mode. Groups 2 to 4 were irradiated at six cycles of 5-sec irradiation/20-sec pause in the microchopped mode (Group 2-1.6 W; Group 3-2.0 W; Group 4-2.5 W). The applied mode was 25 ms on/25 ms off. Within the on period, the laser delivered an intermittent sequence of energy complexes and the maximum output was equal to the nominated output of the device (12 W). Canals were kept moist by sterile saline irrigation in between irradiations, and temperature changes were continuously measured using a thermal imaging camera. Recordings were analyzed by a mixed model (analysis of variance [ANOVA] for repeated measurements). The highest mean of temperature rise, 1.94°C ± 1.07°C, was measured in Group 4, followed by Group 3 (1.74°C ± 1.22°C) and Group 2 (1.58°C ± 1.18°C). The lowest increase occurred in Group 1 (1.06°C ± 1.20°C). There was a significant difference (p = 0.041) between the groups. Significant differences were found between Groups 1 and 4 (p = 0.007) and 1 and 2 (p = 0.035). In addition, a marginally significant difference between Groups 1 and 2 (p = 0.052) was noted. There was no significant difference between Groups 2, 3, and 4. Despite the low mean values reported, the highest temperature increase (+5.7°C) was

  20. Quasistatic field simulations based on finite elements and spectral methods applied to superconducting magnets

    International Nuclear Information System (INIS)

    Koch, Stephan

    2009-01-01

    This thesis is concerned with the numerical simulation of electromagnetic fields in the quasi-static approximation which is applicable in many practical cases. Main emphasis is put on higher-order finite element methods. Quasi-static applications can be found, e.g., in accelerator physics in terms of the design of magnets required for beam guidance, in power engineering as well as in high-voltage engineering. Especially during the first design and optimization phase of respective devices, numerical models offer a cheap alternative to the often costly assembly of prototypes. However, large differences in the magnitude of the material parameters and the geometric dimensions as well as in the time-scales of the electromagnetic phenomena involved lead to an unacceptably long simulation time or to an inadequately large memory requirement. Under certain circumstances, the simulation itself and, in turn, the desired design improvement becomes even impossible. In the context of this thesis, two strategies aiming at the extension of the range of application for numerical simulations based on the finite element method are pursued. The first strategy consists in parallelizing existing methods such that the computation can be distributed over several computers or cores of a processor. As a consequence, it becomes feasible to simulate a larger range of devices featuring more degrees of freedom in the numerical model than before. This is illustrated for the calculation of the electromagnetic fields, in particular of the eddy-current losses, inside a superconducting dipole magnet developed at the GSI Helmholtzzentrum fuer Schwerionenforschung as a part of the FAIR project. As the second strategy to improve the efficiency of numerical simulations, a hybrid discretization scheme exploiting certain geometrical symmetries is established. Using this method, a significant reduction of the numerical effort in terms of required degrees of freedom for a given accuracy is achieved. The

  1. A low noise photoelectric signal acquisition system applying in nuclear magnetic resonance gyroscope

    Science.gov (United States)

    Lu, Qilin; Zhang, Xian; Zhao, Xinghua; Yang, Dan; Zhou, Binquan; Hu, Zhaohui

    2017-10-01

    The nuclear magnetic resonance gyroscope serves as a new generation of strong support for the development of high-tech weapons, it solves the core problem that limits the development of the long-playing seamless navigation and positioning. In the NMR gyroscope, the output signal with atomic precession frequency is detected by the probe light, the final crucial photoelectric signal of the probe light directly decides the quality of the gyro signal. But the output signal has high sensitivity, resolution and measurement accuracy for the photoelectric detection system. In order to detect the measured signal better, this paper proposed a weak photoelectric signal rapid acquisition system, which has high SNR and the frequency of responded signal is up to 100 KHz to let the weak output signal with high frequency of the NMR gyroscope can be detected better.

  2. Applying Closing Phase-Angle Control Technique in Bounce Reduction of AC Permanent Magnet Contactor

    Directory of Open Access Journals (Sweden)

    Chieh-Tsung Chi

    2009-01-01

    Full Text Available A new low-cost electronic control circuit actuator is proposed for minimizing the bouncing times of an AC permanent magnet (PM contactor after two contacts closing. The proposed new actuator overcomes the bouncing problem of an uncontrollable restrictions imposed by previously conventional AC electromagnetic (EM contactor based on the minimization of kinetic energy prior to two contacts impact. By choosing the closing phase angle of coil voltage on purpose, the bouncing problems of the movable contact during the closing process are then overcome. The using life of contacts is then prolonged and their operating reliability is improved as well. In order to validate the feasibility and effectiveness of the proposed method here, several simulation and experimental procedures were performed on a prototype of AC PM contactor in the laboratory. Testing results actually showed that bouncing problem of contactor's contacts during the closing process was to be controlled by using the proposed technology.

  3. Childhood brain tumor occurrence in relation to external power lines and other sources of residential magnetic fields. Final report

    International Nuclear Information System (INIS)

    Gurney, J.G.; Mueller, B.A.; Davis, S.

    1995-10-01

    A population-based case-control study of incident brain tumors was conducted in the Seattle area among children younger than 20 years, diagnosed from 1984-1990; mothers of 133 cases and 270 controls participated. The relation between childhood brain tumor occurrence and exposure to potential sources of residential magnetic fields was assessed, focusing on whether proximity to high-current residential power lines or use of electric appliances or electric heating sources by the mother while pregnant or by the child before diagnosis, were associated with increased risks of brain tumor occurrence. For the 120 cases and 240 controls, risk of brain tumor occurrence did not increase with increasing magnetic field exposure as indicated by the 5-level Wertheimer-Leeper (W-L) code. Relative to those with underground wiring, the odds ratios for increasing exposure levels were: very low current configuration, 1.3; ordinary low current configuration, 0.7; ordinary high-current configuration, 1.1; and very high current configuration, 0.5. When exposure was dichotomized as high versus low, the odds ratio was 0.9 (95% CI 0.5-1.5) and did not vary significantly. When the analysis was restricted to the 96 subjects known to live in only one home, the odds ratio was 1.1. The distributions of the 5-level W-L code were similar between study participants and non-respondents, and odds ratios were not appreciably changed when non-respondents were included in the analysis. No elevations in risk were found for ever-versus-never use of electric blankets, water beds, or electric heating sources. Odds ratios were slightly elevated for nine appliances and were at or below 1.0 for eight others. These data do not support the hypothesis that exposure to magnetic fields from high-current power lines, electric heating sources, or electric appliances, is associated with the subsequent occurrence of brain tumors in children

  4. Intelligent simulated annealing algorithm applied to the optimization of the main magnet for magnetic resonance imaging machine; Algoritmo simulated annealing inteligente aplicado a la optimizacion del iman principal de una maquina de resonancia magnetica de imagenes

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Lopez, Hector [Universidad de Oriente, Santiago de Cuba (Cuba). Centro de Biofisica Medica]. E-mail: hsanchez@cbm.uo.edu.cu

    2001-08-01

    This work describes an alternative algorithm of Simulated Annealing applied to the design of the main magnet for a Magnetic Resonance Imaging machine. The algorithm uses a probabilistic radial base neuronal network to classify the possible solutions, before the objective function evaluation. This procedure allows reducing up to 50% the number of iterations required by simulated annealing to achieve the global maximum, when compared with the SA algorithm. The algorithm was applied to design a 0.1050 Tesla four coil resistive magnet, which produces a magnetic field 2.13 times more uniform than the solution given by SA. (author)

  5. Strike-point splitting induced by external magnetic perturbations: Observations on JET and MAST and associated modelling

    Czech Academy of Sciences Publication Activity Database

    Nardon, E.; Cahyna, Pavel; Devaux, S.; Kirk, A.; Alfier, A.; De La Luna, E.; De Temmerman, G.; Denner, P.; Eich, T.; Gerbaud, T.; Harting, D.; Jachmich, S.; Koslowski, H.R.; Liang, Y.; Sun, Y.

    2011-01-01

    Roč. 415, č. 1 (2011), S914-S917 ISSN 0022-3115. [International Conference on Plasma-Surface Interactions in Controlled Fusion Device/19th./. San Diego, 24.05.2010-28.05.2010] R&D Projects: GA MŠk LA08048 Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamaks * ELM control * resonant magnetic perturbations * divertor Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.052, year: 2011 http://dx.doi.org/10.1016/j.jnucmat.2010.10.072

  6. The ITER 3D Magnetic Diagnostic Response to Applied n=3 and n=4 RMP's

    Energy Technology Data Exchange (ETDEWEB)

    Lazerson, S A [PPPL

    2014-09-01

    The ITER magnetic diagnostic response to applied n=3 and n=4 RMPs has been calculated for the 15MA scenario. The VMEC code was utilized to calculate free boundary 3D ideal MHD equilibria, where the non-stellarator symmetric terms were included in the calculation. This allows an assessment to be made of the possible boundary displacements due to RMP application in ITER. As the VMEC code assumes a continuous set of nested flux surface, the possibility of island and stochastic region formation is ignored. At the start of the current at-top (L-Mode) application of n = 4 RMP's indicates approximately 1 cm peak-to-peak displacements on the low field side of the plasma while later in the shot (H-mode) perturbations as large as 3 cm are present. Forward modeling of the ITER magnetic diagnostics indicates significant non-axisymmetric plasma response, exceeding 10% the axisymmetric signal in many of the flux loops. Magnetic field probes seem to indicate a greater robustness to 3D effects but still indicate large sensitivities to 3D effects in a number of sensors. Forward modeling of the diagnostics response to 3D equilibria allows assessment of diagnostics design and control scenarios.

  7. Spin-orbit coupling and applied magnetic field effects on electromagnetically induced transparency of a quantum ring at finite temperature

    Science.gov (United States)

    Zamani, A.; Setareh, F.; Azargoshasb, T.; Niknam, E.

    2018-03-01

    A wide variety of semiconductor nanostructures have been fabricated and studied experimentally and alongside theoretical investigations show the great role they have in new generation opto-electronic devices. However, mathematical modeling provide important information due to their definitive goal of predicting features and understanding of such structures' behavior under different circumstances. Hence, in the current work, the effects of applied magnetic field, temperature and dimensions of the structure on the electromagnetically induced transparency (EIT) of a GaAs quantum ring are studied while both Rashba and Dresselhaus spin-orbit interactions (SOI) are taken into account. The Schrödinger equation is solved in cylindrical coordinate with axial symmetry and in order to study the EIT, the imaginary (absorption) and real (refractive index) parts of susceptibility as well as the group velocity of the probe light pulse are investigated. The absorption and refractive index plots show that, for a specific frequency of probe field the absorption vanishes and refractive index becomes unity (known as EIT) while around such frequency the group index is positive (sub-luminal probe propagation) and for higher and lower frequencies it alters to negative (super-luminal probe propagation). The numerical results reveal that the EIT frequency, transparency window and sub(super)-luminal frequency intervals shift as we change applied magnetic field, temperature and also the structure dimensions.

  8. The permeability of SPION over an artificial three-layer membrane is enhanced by external magnetic field

    Directory of Open Access Journals (Sweden)

    Ge Xianxi

    2006-04-01

    Full Text Available Abstract Background Sensorineural hearing loss, a subset of all clinical hearing loss, may be correctable through the use of gene therapy. We are testing a delivery system of therapeutics through a 3 cell-layer round window membrane model (RWM model that may provide an entry of drugs or genes to the inner ear. We designed an in vitro RWM model similar to the RWM (will be referred to throughout the paper as RWM model to determine the feasibility of using superparamagnetic iron oxide (Fe3O4 nanoparticles (SPION for targeted delivery of therapeutics to the inner ear. The RWM model is a 3 cell-layer model with epithelial cells cultured on both sides of a small intestinal submucosal (SIS matrix and fibroblasts seeded in between. Dextran encapsulated nanoparticle clusters 130 nm in diameter were pulled through the RWM model using permanent magnets with flux density 0.410 Tesla at the pole face. The SIS membranes were harvested at day 7 and then fixed in 4% paraformaldehyde. Transmission electron microscopy and fluorescence spectrophotometry were used to verify transepithelial transport of the SPION across the cell-culture model. Histological sections were examined for evidence of SPION toxicity, as well to generate a timeline of the position of the SPION at different times. SPION also were added to cells in culture to assess in vitro toxicity. Results Transepithelial electrical resistance measurements confirmed epithelial confluence, as SPION crossed a membrane consisting of three co-cultured layers of cells, under the influence of a magnetic field. Micrographs showed SPION distributed throughout the membrane model, in between cell layers, and sometimes on the surface of cells. TEM verified that the SPION were pulled through the membrane into the culture well below. Fluorescence spectrophotometry quantified the number of SPION that went through the SIS membrane. SPION showed no toxicity to cells in culture. Conclusion A three-cell layer model of the

  9. Magnetic microfluidic platform for biomedical applications using magnetic nanoparticles

    KAUST Repository

    Stipsitz, Martin

    2015-05-01

    Microfluidic platforms are well-suited for biomedical analysis and usually consist of a set of units which guarantee the manipulation, detection and recognition of bioanalyte in a reliable and flexible manner. Additionally, the use of magnetic fields for perfoming the aforementioned tasks has been steadily gainining interest. This is due to the fact that magnetic fields can be well tuned and applied either externally or from a directly integrated solution in the diagnostic system. In combination with these applied magnetic fields, magnetic nanoparticles are used. In this paper, we present some of our most recent results in research towards a) microfluidic diagnostics using MR sensors and magnetic particles and b) single cell analysis using magnetic particles. We have successfully manipulated magnetically labeled bacteria and measured their response with integrated GMR sensors and we have also managed to separate magnetically labeled jurkat cells for single cell analysis. © 2015 Trans Tech Publications, Switzerland.

  10. Applied superconductivity

    CERN Document Server

    Newhouse, Vernon L

    1975-01-01

    Applied Superconductivity, Volume II, is part of a two-volume series on applied superconductivity. The first volume dealt with electronic applications and radiation detection, and contains a chapter on liquid helium refrigeration. The present volume discusses magnets, electromechanical applications, accelerators, and microwave and rf devices. The book opens with a chapter on high-field superconducting magnets, covering applications and magnet design. Subsequent chapters discuss superconductive machinery such as superconductive bearings and motors; rf superconducting devices; and future prospec

  11. Neurons are sensitive to the magnetic fields applied within the range of MR intensity used for diagnostic purposes

    International Nuclear Information System (INIS)

    Azanza, M.J.

    1997-01-01

    A very high number of data, obtained from molecular and cell biology experimental work, show that living beings are sensitive to either the static magnetic fields (SMF) or the electromagnetic fields in the extremely low frequency (ELF) range (1). Considering the question of the intensity range of the SMF applied for clinical diagnosis, we have made experiments by applying SMF (0,3-0,7 T) directly to neurons. We have shown that there exist a neuron magneto sensitivity explained as a result of the diamagnetism of the phospholipid and protein molecules of the lipid bilayer plasma membrane. This diamagnetism is working together with electric dipolar interactions (a mixed up interaction coined as super diamagnetism) and binded membrane Ca''2+ cooperative coulomb explosion, which in turn operate Ca''2+ -dependent-K''+ membrane channels (2,3). The specific intrinsic metabolic characteristics of the neurons populations explain two types of responses: either a variation in the firing frequency (increases or decreases) or a decrease in the spikes amplitude. This second effect is explained by the inhibition of the Na''+ -K''+-ATP-ase ionic pumps, inactivated by the same superdiamagnetims mechanism. We show in this paper the dependence of the frequency and amplitude changes, of the electrophysiological activity of the neurons, with the intensity of the applied SMF. (Author) 30 refs

  12. Magnetic nanotubes for drug delivery

    Science.gov (United States)

    Ramasamy, Mouli; Kumar, Prashanth S.; Varadan, Vijay K.

    2017-04-01

    Magnetic nanotubes hold the potential for neuroscience applications because of their capability to deliver chemicals or biomolecules and the feasibility of controlling the orientation or movement of these magnetic nanotubes by an external magnetic field thus facilitating directed growth of neurites. Therefore, we sought to investigate the effects of laminin treated magnetic nanotubes and external alternating magnetic fields on the growth of dorsal root ganglion (DRG) neurons in cell culture. Magnetic nanotubes were synthesized by a hydrothermal method and characterized to confirm their hollow structure, the hematite and maghemite phases, and the magnetic properties. DRG neurons were cultured in the presence of magnetic nanotubes under alternating magnetic fields. Electron microscopy showed a close interaction between magnetic nanotubes and the growing neurites Phase contrast microscopy revealed live growing neurons suggesting that the combination of the presence of magnetic nanotubes and the alternating magnetic field were tolerated by DRG neurons. The synergistic effect, from both laminin treated magnetic nanotubes and the applied magnetic fields on survival, growth and electrical activity of the DRG neurons are currently being investigated.

  13. Sensitivity degradation of an anger camera operated in SPECT-like mode under the influence of a strong external magnetic field

    International Nuclear Information System (INIS)

    Galiano, Eduardo; Aldarwish, Huda

    2014-01-01

    The purpose of this work was to experimentally determine the degradation in sensitivity of an Anger camera rotated in SPECT-like orbits around the transverse and sagittal planes of the magnetic field produced by a conventional, dual coil, 1 T electromagnet. A 74 photomultiplier Siemens Basicam Anger camera with a 29 cm radius crystal and an Isotrak 35 cm diameter, 46 MBq (1.25 mCi), Co-57 disk source attached to a low energy general purpose collimator, were used for all measurements. A custom made, air-cooled, dual coil, 1 T electromagnet was used to produce the external magnetic field. A map of the magnetic field was obtained by taking intensity measurements around the sagittal and transverse planes of the magnet. Camera sensitivity – defined as the measured count rate for a given activity of a radionuclide in a defined geometry – was first measured around the transverse plane at angles of 0°, 90°, and 270°, with, and without, the magnetic field present. At each angle, three 30 min measurements were made and the average count rate was calculated. A similar protocol was used for measurements upon rotation in the sagittal plane: counts per 30 min interval were measured for 20 angles, with a 15° increment between measurements. Camera sensitivity as a function of field strength was also determined by collecting counts over 30 min intervals at a fixed angle (90°) with magnet currents of 0.00 A, 2.65 A, and 5.30 A. In the transverse plane, at 0° under a field intensity of 21 mT, the loss in sensitivity was 18.14%, at 90° (B=37 mT) the loss was 30.5%, and at 270° (B=38 mT) the loss was 34.9%. Thus for rotation in the transverse plane, the sensitivity is monotonically reduced with an increase in field intensity. On rotation in the sagittal plane, sensitivity degradation ranged between 50.3% at a 22° angle, and 59.1% at 315°. Broad sensitivity peaks were observed at 105° and 195°, with minima at 60°, 135°, and 260°, consistent with our theoretical

  14. Externally triggered microcapsules

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2011-01-01

    Disclosed are microcapsules comprising a polymer shell enclosing one or more immiscible liquid phases in which a drug or drug precursor are contained in a liquid phase. The microparticles also contain magnetic particles that can be heated by application of an external magnetic field and thus heated to a predetermined Curie temperature. Heating of the particles melts the polymer shell and releases the drug without causing heating of surrounding tissues.

  15. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  16. Effect of external magnetic field on valence-electron structures of Fe and Ni in Invar, Permalloy and the other Fe-Ni alloys by using Kβ-to-Kα X-ray intensity ratios.

    Science.gov (United States)

    Alım, Bünyamin; Han, İbrahim; Demir, Lütfü

    2016-06-01

    The effect of external magnetic field on the valence-electron structures of Fe and Ni in various Fe-Ni alloy compositions was investigated by using X-ray fluorescence spectroscopy. Firstly, Kβ-to-Kα X-ray intensity ratios of Fe and Ni in Invar (Fe0.64Ni0.36), Permalloy (Fe0.20Ni0.80) and FexNi1-x (x=0, 0.40, 0.52, 0.55, 0.61, and 1) alloys were measured without any magnetic field and under 0.5 and 1T external magnetic fields, separately. Later, the valence-electron structures of Fe and Ni in both pure form and alloys were obtained by comparison of measured X-ray intensity ratios with the results of multi-configurations Dirac-Fock (MCDF) calculations. The results obtained for valence-electron structures of Fe and Ni in various Fe-Ni alloys were evaluated in terms of magnetic field effect, delocalization and/or charge transfer phenomena. The results have shown that valence electron structure of Fe and Ni in Fe-Ni alloys are dependent on both external magnetic field and concentration of alloy elements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Neutron diffraction studies of magnetic ordering in superconducting ErNi2B2C and TmNi2B2C in an applied magnetic field

    DEFF Research Database (Denmark)

    Toft, Katrine Nørgaard

    The field-induced magnetic structures of ErNi2B2C and TmNi2B2C in are especially interesting because the field suppresses the superconducting order parameter and therefore the magnetic properties can be studied while varying the strength ofsuperconductivity. ErNi2B2C: For magnetic fields along al...

  18. Development of a superconductor magnetic suspension and balance prototype facility for studying the feasibility of applying this technique to large scale aerodynamic testing

    Science.gov (United States)

    Zapata, R. N.; Humphris, R. R.; Henderson, K. C.

    1975-01-01

    The basic research and development work towards proving the feasibility of operating an all-superconductor magnetic suspension and balance device for aerodynamic testing is presented. The feasibility of applying a quasi-six-degree-of freedom free support technique to dynamic stability research was studied along with the design concepts and parameters for applying magnetic suspension techniques to large-scale aerodynamic facilities. A prototype aerodynamic test facility was implemented. Relevant aspects of the development of the prototype facility are described in three sections: (1) design characteristics; (2) operational characteristics; and (3) scaling to larger facilities.

  19. Neutron diffraction studies of magnetic ordering in superconducting ErNi{sub 2}B{sub 2}C and TmNi{sub 2}B{sub 2}C in an applied magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Toft, K.N

    2004-01-01

    The field-induced magnetic structures of ErNi{sub 2}B{sub 2}C and TmNi{sub 2}B{sub 2}C in are especially interesting because the field suppresses the superconducting order parameter and therefore the magnetic properties can be studied while varying the strength of superconductivity. ErNi{sub 2}B{sub 2}C: For magnetic fields along all three symmetry directions, the observed magnetic structures have a period corresponding to the Fermi surface nesting structure. The phase diagrams present all the observed magnetic structures. Two results remain unresolved: 1. When applying the magnetic field along [010], the minority domain (Q{sub N}{sup B} = (0,Q,0) with moments perpendicular to the field) shows no signs of hysteresis. I expected it to be a meta-stable state, which would be gradually suppressed by a magnetic field, and when decreasing the field it would not reappear until some small field of approximately 0.1 T. 2. When the field is applied along [110], the magnetic structure rotates a small angle of 0.5 degrees away from the symmetry direction. TmNi{sub 2}B{sub 2}C: A magnetic field applied in the [100] direction suppresses the zero field magnetic structure Q{sub F} = (0.094,0.094,0) (T{sub N} = 1.6 K), in favor of the Fermi surface nesting structure Q{sub N} = (0.483,0,0). The appearance of the Q{sub N} phase was initially believed to be caused by the suppression of superconductivity. This suppression should make it favorable to create a magnetic order with a Q-vector determined by the maximum in the magnetic susceptibility at the Fermi surface nesting vector Q{sub N}. The phase diagram for the magnetic structures is presented, however several properties of the Q{sub N} magnetic structure cannot be explained within any known models. Quadrupolar ordering is suggested as a possible candidate for explaining these features of the Q{sub N} structure. (au)

  20. DESIGN AND OPTIMIZATION OF PERMANENT MAGNET SYNCHRONOUS GENERATOR FOR USE IN HYDRODYNAMIC RENEWABLE ENERGY BY APPLYING ACO AND FEA

    Directory of Open Access Journals (Sweden)

    Amir Nikbakhsh

    2017-12-01

    Full Text Available One of the most important ways to reduce fossil fuel consumption and consequently reduce greenhouse gases and environmental pollution is the use of renewable energies such as water, sun, wind, etc. One of the most efficient ways to take advantages of the shallow flowing waters such as rivers and fountains in electrical power generation is the use of hydrodynamic screw in the direction of water flow. The design of the generator for this application results in environmental dangers decrease. On the other hand, it provides some part of electrical energy required for human beings. Generators in hydrodynamic renewable energy system ought to have features such as high efficiency, power density and reliability as well as low volume. Among various generators, the permanent magnet synchronous generator (PMSG meets these requirements very well. In this paper, first, analytical calculations and the design process of PMSG were explained. Then, the ant colony optimization (ACO was used for the optimization of design quantities. PMSG design optimization increased in efficiency and decreased in volume. By improving these two parameters in the designed PMSG, it gets very suitable to be used in hydrodynamic renewable energy system. Finally, the results of the optimized design of PMSG were validated through simulation of it in Maxwell software and applying finite element analysis (FEA. Also the final results have been compared to similar experimental researches results.

  1. Performance of a shallow-focus applied-magnetic-field diode for ion-beam-transport experiments

    Energy Technology Data Exchange (ETDEWEB)

    Young, F.C.; Neri, J.M.; Ottinger, P.F. [Naval Research Lab., Washington, DC (United States); Rose, D.V. [JAYCOR, Vienna (Vatican City State, Holy See); Jones, T.G.; Oliver, B.V.

    1997-12-31

    An applied-magnetic-field ion diode to study the transport of intense ion beams for light-ion inertial confinement fusion is being operated on the Gamble II generator at NRL. A Large-area (145-cm{sup 2}), shallow-focusing diode is used to provide the ion beam required for self-pinched transport (SPT) experiments. Experiments have demonstrated focusing at 70 cm for 1.2-MV, 40-kA protons. Beyond the focus, the beam hollows out consistent with 20--30 mrad microdivergence. The effect of the counter-pulse B-field on altering the ion-beam trajectories and improving the focus has been diagnosed with a multiple-pinhole-camera using radiachromic film. This diagnostic is also used to determine the radial and azimuthal uniformity of ion emission at the anode for different B-field conditions. Increasing the diode voltage to 1.5 MV and optimizing the ion current are planned before initiating SPT experiments. Experiments to measure the spatial beam profile at focus, i.e., the SPT channel entrance, are in progress. Results are presented.

  2. Temperature dependent and applied field strength dependent magnetic study of cobalt nickel ferrite nano particles: Synthesized by an environmentally benign method

    Science.gov (United States)

    Sontu, Uday Bhasker; G, Narsinga Rao; Chou, F. C.; M, V. Ramana Reddy

    2018-04-01

    Spinel ferrites have come a long way in their versatile applications. The ever growing applications of these materials demand detailed study of material properties and environmental considerations in their synthesis. In this article, we report the effect of temperature and applied magnetic field strength on the magnetic behavior of the cobalt nickel ferrite nano powder samples. Basic structural properties of spinel ferrite nano particles, that are synthesized by an environmentally benign method of auto combustion, are characterized through XRD, TEM, RAMAN spectroscopy. Diffuse Reflectance Spectroscopy (DRS) is done to understand the nickel substitution effect on the optical properties of cobalt ferrite nano particles. Thermo magnetic studies using SQUID in the temperature range 5 K to 400 K and room temperature (300 K) VSM studies are performed on these samples. Fields of 0Oe (no applied field: ZF), 1 kOe (for ZFC and FC curves), 5 kOe (0.5 T), 50 kOe (5T) (for M-H loop study) are used to study the magnetic behavior of these nano particles. The XRD,TEM analysis suggest 40 nm crystallites that show changes in the cation distribution and phase changes in the spinel structure with nickel substitution. Raman micrographs support phase purity changes and cation redistributions with nickel substitution. Diffuse reflectance study on powder samples suggests two band gap values for nickel rich compounds. The Magnetic study of these sample nano particles show varied magnetic properties from that of hard magnetic, positive multi axial anisotropy and single-magnetic-domain structures at 5 K temperature to soft magnetic core shell like structures at 300 K temperature. Nickel substitution effect is non monotonous. Blocking temperature of all the samples is found to be higher than the values suggested in the literature.

  3. Proposal of requirements for performance in Brazil for systems of external individual monitoring for neutrons applying the TLD-albedo technique

    International Nuclear Information System (INIS)

    Martins, Marcelo M.; Mauricio, Claudia L.P.; Pereira, Walsan W.; Fonseca, Evaldo S. da; Silva, Ademir X.

    2009-01-01

    This work presents a criteria and conditions proposal for the regulations in Brazil of individual monitoring systems for neutrons applying the albedo technique with thermoluminescent detectors. Tests are proposed for the characterization performance of the system based on the Regulation ISO 21909 and on the experience of the authors

  4. Bioavailability of magnetic nanoparticles to the brain

    Energy Technology Data Exchange (ETDEWEB)

    Huang, B.-R. [Department of Neurosurgery, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China); Chen, P.-Y. [Department of Neurosurgery, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China); Graduate Institute of Biomedical Sciences, Chang-Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Taoyuan 333, Taiwan (China); Huang, C.-Y. [Department of Neurosurgery, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China); Jung, S.-M. [Department of Pathology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China); Ma, Y.-H. [Department of Physiology and Pharmacology, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Wu, Tony [Department of Neurology, Chang Gung Memorial Hospital, Chang Gung University, College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China); Chen, J.-P. [Department of Chemical and Material Engineering, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China)], E-mail: jpchen@mail.cgu.edu.tw; Wei, K.-C. [Department of Neurosurgery, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 5 Fushing Street, Kweishan, Taoyuan 333, Taiwan (China)], E-mail: kuochenwei@adm.cgmh.org.tw

    2009-05-15

    This study investigates the bioavailability of carboxymethyl dextran-coated magnetic nanoparticles (CMD-MNP) to the brain. The cytotoxicity of CMD-MNP was assessed by co-culture with C6, a rat glioma cell line. To investigate the effects of an external magnetic field on the biodistribution of nanoparticles in a rat model, a magnet of 0.3 Tesla was applied externally over the cranium and the particles injected via the external jugular vein. Nanoparticles were also injected into rats implanted with C6 tumor cells. Staining of histological samples with Prussian blue to detect iron particles revealed that the external magnetic field enhanced the aggregation of nanoparticles in the rat brain; this enhancement was even more pronounced in the tumor region.

  5. Transient Magnetic Field in a Conducting Cylinder

    Directory of Open Access Journals (Sweden)

    Zygmunt Piatek

    2004-01-01

    Full Text Available In the paper we determine the transient magnetic field in a conducting cylinder placed in external longitudinal sine-shaped magnetic field using the solution of Bessell equation in cylindrical co-ordinates, and also applying integral Laplace transformations, attenuation and diffusion of the magnetic field strength in the cylinder. The resulting equations can be used to describe volume density of the power lost in the cylinder and to determine substitute parameters of the inductor-cylindrical work system.

  6. Evolution of Ni3X Precipitation Kinetics, Morphology and Spatial Correlations in Binary Ni-X Alloys Aged Under Externally Applied Stress

    Energy Technology Data Exchange (ETDEWEB)

    Ardell, Alan J

    2006-02-07

    Coarsening of Ni3Al, Ni3Ga, Ni3Ge and Ni3Si precipitates in aged binary single-crystal Ni-Al, Ni-Ga, Ni-Ge and Ni-Si alloys under applied compressive stress was measured experimentally over the temperature range 600 to 700 °C. Experiments were also performed on binary Ni-Al single crystals deformed in tension at 640°C. The orientation of the crystals was [100] in all the experiments. Compared to the kinetics of coarsening in unstressed alloys, coarsening was slightly slower in specimens aged under compression and slightly faster in specimens aged in tension. The effect of applied stress on morphology and spatial correlation was also measured and found to be small. Ni3Al precipitates of a given size generally tended to become more non-equiaxed and their interfaces more planar, with increasing compressive stress. Ni3Ge precipitates behaved differently, becoming more spherical in specimens aged under compression. The effect of applied stress on kinetics is attributed to the influence of elastic deformation on diffusion. A model was developed that predicts slightly slower diffusion under compression and slightly faster diffusion in tension. The elastic constants of single crystals of Ni-Al, Ni-Si, Ni-Ga and Ni-Ge solid solutions were measured from room temperature to about 1100 K using resonant ultrasound spectroscopy.

  7. Pulsed-coil magnet systems for applying uniform 10–30 T fields to centimeter-scale targets on Sandia's Z facility

    Energy Technology Data Exchange (ETDEWEB)

    Rovang, D. C., E-mail: dcrovan@sandia.gov; Lamppa, D. C.; Cuneo, M. E.; Owen, A. C.; McKenney, J.; Johnson, D. W.; Radovich, S.; Kaye, R. J.; McBride, R. D.; Alexander, C. S.; Awe, T. J.; Slutz, S. A.; Sefkow, A. B.; Haill, T. A.; Jones, P. A.; Argo, J. W.; Dalton, D. G.; Robertson, G. K.; Waisman, E. M.; Sinars, D. B. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185 (United States); and others

    2014-12-15

    Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10–30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1–3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2–7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

  8. Pulsed-coil magnet systems for applying uniform 10-30 T fields to centimeter-scale targets on Sandia's Z facility.

    Science.gov (United States)

    Rovang, D C; Lamppa, D C; Cuneo, M E; Owen, A C; McKenney, J; Johnson, D W; Radovich, S; Kaye, R J; McBride, R D; Alexander, C S; Awe, T J; Slutz, S A; Sefkow, A B; Haill, T A; Jones, P A; Argo, J W; Dalton, D G; Robertson, G K; Waisman, E M; Sinars, D B; Meissner, J; Milhous, M; Nguyen, D N; Mielke, C H

    2014-12-01

    Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10-30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1-3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2-7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

  9. Pulsed-coil magnet systems for applying uniform 10-30 T fields to centimeter-scale targets on Sandia's Z facility

    Science.gov (United States)

    Rovang, D. C.; Lamppa, D. C.; Cuneo, M. E.; Owen, A. C.; McKenney, J.; Johnson, D. W.; Radovich, S.; Kaye, R. J.; McBride, R. D.; Alexander, C. S.; Awe, T. J.; Slutz, S. A.; Sefkow, A. B.; Haill, T. A.; Jones, P. A.; Argo, J. W.; Dalton, D. G.; Robertson, G. K.; Waisman, E. M.; Sinars, D. B.; Meissner, J.; Milhous, M.; Nguyen, D. N.; Mielke, C. H.

    2014-12-01

    Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10-30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1-3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2-7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

  10. Magnetic field induced augmented thermal conduction phenomenon in magneto nanocolloids

    OpenAIRE

    Katiyar, Ajay; Dhar, Purbarun; Nandi, Tandra; Das, Sarit K.

    2015-01-01

    Magnetic field induced drastically augmented thermal conductivity of magneto nanocolloids involving magnetic oxide nanoparticles, viz. Fe2O3, Fe3O4, Nickel oxide (NiO), Cobalt oxide (Co3O4), dispersed in different base fluids (heat transfer oil, kerosene, and ethylene glycol) have been reported. Experiments reveal the augmented thermal transport under the external applied magnetic field, with kerosene based MNCs showing at relatively low magnetic field intensities as compared to the heat tran...

  11. Effect of external magnetic field on the Kβ/Kα X-ray intensity ratios of TixNi1-x alloys excited by 59.54 and 22.69keV photons.

    Science.gov (United States)

    Perişanoğlu, Ufuk; Alım, Bünyamin; Uğurlu, Mine; Demir, Lütfü

    2016-09-01

    The effects of external magnetic field and exciting photon energies on the Kβ/Kα X-ray intensity ratios of various alloy compositions of Ti-Ni transition metal alloys have been investigated in this work using X-ray fluorescence spectroscopy. The spectrum of characteristic K-X-ray photons from pure Ti, pure Ni and TixNi1-x (x=0.30; 0.40; 0.50; 0.60; 0.70) alloys were detected with a high resolution Si (Li) solid-state detector. Firstly, Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni and TixNi1-x alloys were measured following excitation by 59.54keV γ-rays from a 200mCi (241)Am radioactive point source without any magnetic field and under 0.5 and 1T external magnetic fields, separately. Later, the same measurements were repeated under the same experimental conditions for 22.69keV X-rays from a 370 MBq(1)(0)(9)Cd radioactive point source. The results obtained for Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni, Ti and Ni in various Ti-Ni alloys were evaluated in terms of both external magnetic field effect and exciting photon energy effect. When the results obtained for both exciting photon energies are evaluated in terms of changing of Kβ/Kα X-ray intensity ratios depending on the alloy composition, the tendency of these changes are observed to be similar. Also, Kβ/Kα X-ray intensity ratios for all samples examined have changed with increasing external magnetic field. Therefore, the results obtained have shown that Kβ/Kα X-ray intensity ratios of Ti and Ni in TixNi1-x alloys are connected with the external magnetic field. The present study makes it possible to perform reliable interpretation of experimental Kβ/Kα X-ray intensity ratios for Ti, Ni and TixNi1-x alloys and can also provide quantitative information about the changes of the Kβ/Kα X-ray intensity ratios of these metals with alloy composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Fast ignition realization experiment with high-contrast kilo-joule peta-watt LFEX laser and strong external magnetic field

    Science.gov (United States)

    Fujioka, Shinsuke; Arikawa, Yasunobu; Kojima, Sadaoki; Johzaki, Tomoyuki; Nagatomo, Hideo; Sawada, Hiroshi; Lee, Seung Ho; Shiroto, Takashi; Ohnishi, Naofumi; Morace, Alessio; Vaisseau, Xavier; Sakata, Shohei; Abe, Yuki; Matsuo, Kazuki; Farley Law, King Fai; Tosaki, Shota; Yogo, Akifumi; Shigemori, Keisuke; Hironaka, Yoichiro; Zhang, Zhe; Sunahara, Atsushi; Ozaki, Tetsuo; Sakagami, Hitoshi; Mima, Kunioki; Fujimoto, Yasushi; Yamanoi, Kohei; Norimatsu, Takayoshi; Tokita, Shigeki; Nakata, Yoshiki; Kawanaka, Junji; Jitsuno, Takahisa; Miyanaga, Noriaki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Kondo, Kotaro; Bailly-Grandvaux, Mathieu; Bellei, Claudio; Santos, João Jorge; Azechi, Hiroshi

    2016-05-01

    plasma. Following the above improvements, conversion of 13% of the LFEX laser energy to a low energy portion of the REB, whose slope temperature is 0.7 MeV, which is close to the ponderomotive scaling value, was achieved. To meet the second requirement, the compression of a solid spherical ball with a diameter of 200-μm to form a dense core with an areal density of ˜0.07 g/cm2 was induced by a laser-driven spherically converging shock wave. Converging shock compression is more hydrodynamically stable compared to shell implosion, while a hot spot cannot be generated with a solid ball target. Solid ball compression is preferable also for compressing an external magnetic field to collimate the REB to the fuel core, due to the relatively small magnetic Reynolds number of the shock compressed region. To meet the third requirement, we have generated a strong kilo-tesla magnetic field using a laser-driven capacitor-coil target. The strength and time history of the magnetic field were characterized with proton deflectometry and a B-dot probe. Guidance of the REB using a 0.6-kT field in a planar geometry has been demonstrated at the LULI 2000 laser facility. In a realistic FI scenario, a magnetic mirror is formed between the REB generation point and the fuel core. The effects of the strong magnetic field on not only REB transport but also plasma compression were studied using numerical simulations. According to the transport calculations, the heating efficiency can be improved from 0.4% to 4% by the GEKKO and LFEX laser system by meeting the three requirements described above. This efficiency is scalable to 10% of the heating efficiency by increasing the areal density of the fuel core.

  13. Dipolar structures in magnetite ferrofluids studied with small-angle neutron scattering with and without applied magnetic field

    NARCIS (Netherlands)

    Klokkenburg, M.; Erne, B.H.; Wiedenmann, A.; Petukhov, A.V.; Philipse, A.P.

    2007-01-01

    Field-induced structure formation in a ferrofluid with well-defined magnetite nanoparticles with a permanent magnetic dipole moment was studied with small-angle neutron scattering (SANS) as a function of the magnetic interactions. The interactions were tuned by adjusting the size of the

  14. A Novel Hysteresis Model of Magnetic Field Strength Determined by Magnetic Induction Intensity for Fe-3% Si Electrical Steel Applied in Cigarette Making Machines

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2016-01-01

    Full Text Available Hysteresis characteristics of grain-oriented electrical steel were studied through the hysteresis loop. Existing hysteresis fitting simulation methods were summarized, and new Fe-3% Si grain-oriented electrical steel hysteresis loop model was proposed. Undetermined coefficients of the magnetic field intensity and magnetic flux density were determined by both the fixed angle method and the least squares method, and the hysteresis loop model was validated with high fitting degree by experimental data.

  15. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  16. Magnetic-Field-Driven Artificial Muscle based on the H. Huxley Model: Fundamental Experiments

    Science.gov (United States)

    Hosoda, Makoto; Nishimoto, Yoshiko; Nashima, Shigeki

    2007-03-01

    We experimentally demonstrate an artificial muscle driven by an externally applied magnetic field. The drive mechanism simulated a model proposed by H. Huxley for bionic muscle contraction. Small magnetic needles swing with a time-varying magnetic field and enable linear motion of an object on the needles. In the future, this fundamental mechanism could prove useful for realizing linear actuators for robots.

  17. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

    International Nuclear Information System (INIS)

    Dowling, Jason A.; Sun, Jidi; Pichler, Peter; Rivest-Hénault, David; Ghose, Soumya; Richardson, Haylea; Wratten, Chris; Martin, Jarad; Arm, Jameen; Best, Leah; Chandra, Shekhar S.; Fripp, Jurgen; Menk, Frederick W.; Greer, Peter B.

    2015-01-01

    Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic s

  18. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

    Energy Technology Data Exchange (ETDEWEB)

    Dowling, Jason A., E-mail: jason.dowling@csiro.au [CSIRO Australian e-Health Research Centre, Herston, Queensland (Australia); University of Newcastle, Callaghan, New South Wales (Australia); Sun, Jidi [University of Newcastle, Callaghan, New South Wales (Australia); Pichler, Peter [Calvary Mater Newcastle Hospital, Waratah, New South Wales (Australia); Rivest-Hénault, David; Ghose, Soumya [CSIRO Australian e-Health Research Centre, Herston, Queensland (Australia); Richardson, Haylea [Calvary Mater Newcastle Hospital, Waratah, New South Wales (Australia); Wratten, Chris; Martin, Jarad [University of Newcastle, Callaghan, New South Wales (Australia); Calvary Mater Newcastle Hospital, Waratah, New South Wales (Australia); Arm, Jameen [Calvary Mater Newcastle Hospital, Waratah, New South Wales (Australia); Best, Leah [Department of Radiology, Hunter New England Health, New Lambton, New South Wales (Australia); Chandra, Shekhar S. [School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, Queensland (Australia); Fripp, Jurgen [CSIRO Australian e-Health Research Centre, Herston, Queensland (Australia); Menk, Frederick W. [University of Newcastle, Callaghan, New South Wales (Australia); Greer, Peter B. [University of Newcastle, Callaghan, New South Wales (Australia); Calvary Mater Newcastle Hospital, Waratah, New South Wales (Australia)

    2015-12-01

    Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic s

  19. Localization of magnetic pills

    Science.gov (United States)

    Laulicht, Bryan; Gidmark, Nicholas J.; Tripathi, Anubhav; Mathiowitz, Edith

    2011-01-01

    Numerous therapeutics demonstrate optimal absorption or activity at specific sites in the gastrointestinal (GI) tract. Yet, safe, effective pill retention within a desired region of the GI remains an elusive goal. We report a safe, effective method for localizing magnetic pills. To ensure safety and efficacy, we monitor and regulate attractive forces between a magnetic pill and an external magnet, while visualizing internal dose motion in real time using biplanar videofluoroscopy. Real-time monitoring yields direct visual confirmation of localization completely noninvasively, providing a platform for investigating the therapeutic benefits imparted by localized oral delivery of new and existing drugs. Additionally, we report the in vitro measurements and calculations that enabled prediction of successful magnetic localization in the rat small intestines for 12 h. The designed system for predicting and achieving successful magnetic localization can readily be applied to any area of the GI tract within any species, including humans. The described system represents a significant step forward in the ability to localize magnetic pills safely and effectively anywhere within the GI tract. What our magnetic pill localization strategy adds to the state of the art, if used as an oral drug delivery system, is the ability to monitor the force exerted by the pill on the tissue and to locate the magnetic pill within the test subject all in real time. This advance ensures both safety and efficacy of magnetic localization during the potential oral administration of any magnetic pill-based delivery system. PMID:21257903

  20. Toroidal plasma response to external fields

    International Nuclear Information System (INIS)

    Storer, R.G.

    1998-01-01

    Toroidal plasmas respond to external driving fields in a way which is determined by the coupling of these fields to the spectrum of the plasma. We have extended the toroidal resistive magnetohydrodynamic spectral code, SPECTOR, to include the effects of external fields on tokamak-like plasmas. The code is capable of determining both the stable and unstable modes and also the response to helical applied fields with arbitrary mode structure. Resistivity changes the continuous regions of the ideal MHD spectrum into a set of discrete eigenvalues lying along lines in the complex frequency plane with a spacing which is related to the inverse of the square root of the magnetic Reynolds number. Results are presented which relate the spectral distribution to the plasma response as a function of frequency. (author)

  1. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  2. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  3. Magnetism of UCo.sub.2./sub.Si.sub.2./sub. single crystal studied under applied magnetic field and hydrostatic pressure

    Czech Academy of Sciences Publication Activity Database

    Mihalik, M.; Kolomiyets, O.; Griveau, J.C.; Andreev, Alexander V.; Sechovský, V.

    2007-01-01

    Roč. 76, Suppl. A (2007), s. 54-55 ISSN 0031-9015 R&D Projects: GA ČR GA202/06/0178 Institutional research plan: CEZ:AV0Z10100520 Keywords : uranium intermetallics * single crystals * antiferromagnetism * high pressure Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.212, year: 2007

  4. Magnetic field induced assembling of nanoparticles in ferrofluidic ...

    Indian Academy of Sciences (India)

    Unknown

    The effect of a magnetic field on these thin films will have a profound influence on the birefringent properties of these fluid films. If an external magnetic field is applied parallel to .... mission through ferrofluid thin film (Normal incidence and de- tection with respect to ... lation, only the Zeeman energy term (Ez = –µH cosθ) is.

  5. A Method for Utilizing Commercially Available Sensors to Investigate Magnetic Field Perturbations Associated with Ballistic Events

    Science.gov (United States)

    2011-08-01

    applied magnetic field (1). Each orthogonally oriented sensor consists of a Wheatstone bridge with elements fabricated from AMR material, as illustrated...In the absence of an external magnetic field, each Wheatstone bridge element has the same nominal resistance, R. Under these conditions the bridge ...is balanced and an externally applied voltage VCC will generate a bridge voltage of ΔV=0. The magnetoresistive elements of the Wheatstone bridge are

  6. Restricted magnetically balanced basis applied for relativistic calculations of indirect nuclear spin-spin coupling tensors in the matrix Dirac-Kohn-Sham framework

    International Nuclear Information System (INIS)

    Repisky, Michal; Komorovsky, Stanislav; Malkina, Olga L.; Malkin, Vladimir G.

    2009-01-01

    The relativistic four-component density functional approach based on the use of restricted magnetically balanced basis (mDKS-RMB), applied recently for calculations of NMR shielding, was extended for calculations of NMR indirect nuclear spin-spin coupling constants. The unperturbed equations are solved with the use of a restricted kinetically balanced basis set for the small component while to solve the second-order coupled perturbed DKS equations a restricted magnetically balanced basis set for the small component was applied. Benchmark relativistic calculations have been carried out for the X-H and H-H spin-spin coupling constants in the XH 4 series (X = C, Si, Ge, Sn and Pb). The method provides an attractive alternative to existing approximate two-component methods with transformed Hamiltonians for relativistic calculations of spin-spin coupling constants of heavy-atom systems. In particular, no picture-change effects arise in our method for property calculations

  7. Studies on the response of resistive-wall modes to applied magnetic perturbations in the EXTRAP T2R reversed field pinch

    Science.gov (United States)

    Gregoratto, D.; Drake, J. R.; Yadikin, D.; Liu, Y. Q.; Paccagnella, R.; Brunsell, P. R.; Bolzonella, T.; Marchiori, G.; Cecconello, M.

    2005-09-01

    Arrays of magnetic coils and sensors in the EXTRAP T2R [P. R. Brunsell et al., Plasma Phys. Controlled Fusion 43 1457 (2001)] reversed-field pinch have been used to investigate the plasma response to an applied resonant magnetic perturbation in the range of the resistive-wall modes (RWMs). Measured RWM growth rates agree with predictions of a cylindrical ideal-plasma model. The linear growth of low-n marginally stable RWMs is related to the so-called resonant-field amplification due to a dominant ∣n∣=2 machine error field of about 2 G. The dynamics of the m =1 RWMs interacting with the applied field produced by the coils can be accurately described by a two-pole system. Estimated poles and residues are given with sufficient accuracy by the cylindrical model with a thin continuous wall.

  8. Effect of the applied magnetic field and the layer thickness on the magnon properties in bilayers Co/Pt and symmetrical trilayer Pt/Co/Pt

    International Nuclear Information System (INIS)

    Mehdioui, M.; Fahmi, A.; Lassri, H.; Fahoume, M.; Qachaou, A.

    2014-01-01

    We have studied the elementary magnetic excitations and their dynamics in multilayer Co(t Co)/Pt(t Pt) and Pt(t Pt)/Co(t Co)/Pt(t Pt) under an applied magnetic field. The Heisenberg hamiltonian used takes into account the magneto-crystalline and surface anisotropies, the exchange and dipolar interactions. The calculated excitation spectrum ε N (k) presents a structure with two sub-bands corresponding to the magnons of surface and volume respectively. The existence of a gap of creating these magnons is also highlighted. The lifetimes deduced from these gaps are in good agreement with the results of previous studies. The thermal evolution of the magnetization m z indicates that the system undergoes a dimensional crossover 3D–2D when the temperature increases. The calculated and measured magnetizations are compared and they are in good agreement. The exchange integral and critical temperature values deduced from these adjustments are in very good agreement with the results of previous works. - Highlights: • The magnons of surface and volume exist in Co/Pt and Pt/Co/Pt. • Samples undergo dimensional crossover (3D–2D) when T increases. • A good agreement is obtained between M(T) measured and calculated. • Deduced exchange integrals and critical temperature values are correct. • The magnetism of the sample is reduced by increasing t Pt or capping Co by two Pt layers

  9. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  10. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  11. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  12. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  13. Theoretical investigation of the extinction coefficient of magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Fang Xiaopeng; Xuan Yimin, E-mail: ymxuan@mail.njust.edu.cn; Li Qiang [Nanjing University of Science and Technology, School of Energy and Power Engineering (China)

    2013-05-15

    A new theoretical approach for calculating the extinction coefficient of magnetic fluid is proposed, which is based on molecular dynamics (MD) simulation and T-matrix method. By means of this approach, the influence of particle diameter, particle volume fraction, and external magnetic filed on the extinction coefficient of magnetic fluid is investigated. The results show that the extinction coefficient of the magnetic fluid linearly increases with increase in the particle volume fraction. For a given particle volume fraction, the extinction coefficient increases with increase in the particle diameter which varies from 5 to 20 nm. When a uniform external magnetic filed is applied to the magnetic fluid, the extinction coefficient of the magnetic fluid presents an anisotropic feature. These results agree well with the reported experimental results. The proposed approach is applicable to investigating the optical properties of magnetic fluids.

  14. Development of Image Overlay and Knowledge Transfer Module Technologies Aimed at Enhancing Feasibility and External Validation of Magnetic Resonance Imaging-based Scoring Systems.

    Science.gov (United States)

    Jaremko, Jacob L; Pitts, Meaghan; Maksymowych, Walter P; Lambert, Robert G

    2016-01-01

    Semiquantitative arthritis scoring assesses disease burden by scoring presence/extent of features such as bone marrow lesion (BML) or effusion in multiple anatomic regions at a joint. An image overlay clarifying region borders may enhance feasibility and reliability of these scoring systems. To be scalable for use in large clinical trials, systematic computer-based user training is desirable. We developed an overlay and user training module for magnetic resonance imaging (MRI)-based scoring of hip osteoarthritis (OA). We designed a semitransparent 2-dimensional image overlay applied to individual MRI slices to facilitate hip OA scoring [HIMRISS (Hip Inflammation MRI Scoring System)], initially using freeware and then in a customized HTML Web browser environment. We developed a systematic knowledge translation package including instructional presentation, fully scored expert consensus cases, and video tutorials for training in the use of these scoring systems with the overlays. Three musculoskeletal radiologists who had not used this scoring system before each performed a scoring exercise with no overlay, then repeated this with overlays after completing the training module. Based on postexercise interviews and a reader survey, we identified and corrected problems in the module. The entire training process was then repeated using 3 new readers. Overlays were considered useful, particularly when integrated into a Web browser. The knowledge translation module was considered conceptually valuable, but as initially implemented was too lengthy and not sufficiently interactive. Semitransparent image overlays and standardized knowledge translation modules for reader training show promise to facilitate reader calibration using MRI-based scoring systems. Based on our experience, knowledge translation modules should emphasize close feedback evaluating performance and reader time efficiency.

  15. Quantification of Force and Torque Applied by a High-Field Magnetic Resonance Imaging System on an Ultrasonic Motor for MRI-Guided Robot-Assisted Interventions

    Directory of Open Access Journals (Sweden)

    Peyman Shokrollahi

    2017-09-01

    Full Text Available The risk of accidental dislodgement of robot-operated surgical mechanisms can lead to morbidity or mortality. The force and torque applied by a 3.0-tesla scanner on an ultrasonic motor are not fully known. The force and torque may displace the motor, which is not fully magnetic resonance imaging (MRI-compatible but can be safely used in MR environments. A suspension apparatus was designed to measure the angles of deflection and rotation applied to the motor by MR magnetic fields. Three orientations and two power states of the motor were assessed inside the MR bore. The displacement force and torque were measured at eight locations with respect to the bore. The displacement force on the motor from 10 cm outside the magnet bore to 20 cm inside the bore ranged from 3 to 7 gF. The experimental measurements are in agreement with the theoretical values. Running the motor altered the force by 1 gF. The force does not significantly change when the MRI scanner is on. Considerable displacement force is applied to the motor, and no deflection torque is observed. Quantified values can be used to solve dynamic equations for robotic mechanisms intended for MRI-guided operations.

  16. Thermopower of Ce{sub 1–x}La{sub x}Cu{sub 4}Al in applied magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Falkowski, M., E-mail: falkowski@ifmpan.poznan.pl [Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Poznań (Poland); Physics Department, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Kowalczyk, A. [Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Poznań (Poland)

    2014-04-05

    Highlights: • The position of the T{sub max} in S(T) is almost independent of Ce concentration and applied magnetic field. • The S{sub ph-drag} itself is insensitive to the applied magnetic field. • Below 20 K the S(T) value depends strongly on the magnetic field. • A field dependent contribution to low temperature S(T) come from the diffusion term S(T) ≈ S{sub d}(T) = αT. • For low temperature region the Fermi-liquid regime seems suppressed with regard on lack of constant behavior of S/T(T). -- Abstract: Here we report the continued investigations of thermopower S(T) for Ce{sub 1–x}La{sub x}Cu{sub 4}Al intermetallic alloys, particularly focusing on the influence of the applied magnetic fields. In comparison to CeCu{sub 4}Al, the substitution of Ce by La reduces the S(T) values. S(T) of Ce{sub 1–x}La{sub x}Cu{sub 4}Al compounds exhibit positive values and large maximum at T{sub max} ≈ 30 K. However, the positive sign of S(T) for Ce{sub 1–x}La{sub x}Cu{sub 4}Al is consistent to that generally observed in Ce-based systems, which is positive due to the location of a narrow Kondo resonance peak slightly above the Fermi energy level (E{sub F}). The large peak may be due to the Kondo effect in the presence of a crystal-field splitting (CEF) of the Ce 4f-electron. The peak position and absolute value above T{sub max} of S(T) is unaffected by an applied magnetic field. At low temperatures the S(T) value depends strongly on the magnetic field. The S/T(T) shows a strong temperature dependence at low temperature which is consistent with the temperature dependence of heat capacity and electrical resistivity.

  17. Mesoscopic spin-flip transport through a hybrid system with a single molecular dot system applied with ac magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Chen Qiao, E-mail: cqhy1127@yahoo.com.c [Department of Maths and Physics, Hunan Institute of Engineering, Xiangtan 411104 (China); Liu Jin [Institute of Theoretical Physics, Chinese Academy of Science, Beijing 100190 (China); Wang Zhiyong [School of Optoelectronic Information, Chongqing University of Technology, Chongqing 400054 (China)

    2011-01-17

    We have investigated the current for the system of vibrating quantum dot irradiated with a rotating magnetic field and an oscillating magnetic field by nonequilibrium Green's function. The rotating magnetic field rotates with the angular frequency {omega}{sub r} around the z-axis with the tilt angle {theta}, and the time-oscillating magnetic field is located in the z-axis with the angular frequency {omega}. Different behaviors have been shown in the presence of electron-phonon interaction (EPI) which plays a significant role in the transport. The current displays asymmetric behavior as the source-drain bias eV=0, novel side peaks or shoulders can be found due to the phonon absorption and emission procedure, and the negative differential resistance becomes stronger as the parameter g increases. Furthermore, the strong EPI also destroys the quasiperiodic oscillations of current in the region {mu}{sub 0}B{sub 1}>2.5{Delta}. The electron transport properties are also significantly influenced by the linewidth function {Gamma}.

  18. Magnetic fields and scintillator performance

    International Nuclear Information System (INIS)

    Green, D.; Ronzhin, A.; Hagopian, V.

    1995-06-01

    Experimental data have shown that the light output of a scintillator depends on the magnitude of the externally applied magnetic fields, and that this variation can affect the calorimeter calibration and possibly resolution. The goal of the measurements presented here is to study the light yield of scintillators in high magnetic fields in conditions that are similar to those anticipated for the LHC CMS detector. Two independent measurements were performed, the first at Fermilab and the second at the National High Magnetic Field Laboratory at Florida State University

  19. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  20. A fluxonium-based artificial molecule with a tunable magnetic moment

    Science.gov (United States)

    Kou, A.; Smith, W. C.; Vool, U.; Brierley, R. T.; Meier, H.; Frunzio, L.; Girvin, S. M.; Glazman, L. I.; Devoret, M. H.

    We have designed and measured an engineered artificial molecule, composed of two strongly coupled fluxonium atoms, which possesses a tunable magnetic moment. An externally applied magnetic flux tunes the molecule between two regimes: one in which the ground-excited state manifold has a magnetic dipole moment and one in which the ground-excited state manifold has only a magnetic quadrupole moment. By varying the applied external flux, we find the coherence of the molecule to be limited by local flux noise. Work supported by: ARO, ONR, NSF, AFOSR, and YINQE.

  1. Comparison of different cryogenic control strategies via simulation applied to a superconducting magnet test bench at CERN

    Science.gov (United States)

    Arpaia, P.; Coppier, H.; De Paola, D.; di Bernardo, M.; Guarino, A.; Pedemonte, B. Luz; Pezzetti, M.

    2017-12-01

    Industrial process controllers for cryogenic systems used in test facilities for superconducting magnets are typically PIDs, tuned by operational expertise according to users’ requirements (covering cryogenic transients and associated thermo-mechanical constraints). In this paper, an alternative fully-automatic solution, equally based on PID controllers, is proposed. Following the comparison of the operational expertise and alternative fully-automatic approaches, a new process control configuration, based on an estimated multiple-input/multiple-output (MIMO) model is proposed. The new MIMO model-based approach fulfils the required operational constraints while improving performance compared to existing solutions. The analysis and design work is carried out using both theoretical and numerical tools and is validated on the case study of the High Field Magnet (HFM) cryogenic test bench running at the SM18 test facility located at CERN. The proposed solution have been validated by simulation using the CERN ECOSIMPRO software tools using the cryogenic library (CRYOLIB [1]) developed at CERN.

  2. Swimming behaviour of the multicellular magnetotactic prokaryote 'Candidatus Magnetoglobus multicellularis' under applied magnetic fields and ultraviolet light.

    Science.gov (United States)

    Almeida, Fernando P; Viana, Nathan B; Lins, Ulysses; Farina, Marcos; Keim, Carolina N

    2013-04-01

    Magnetotactic bacteria move by rotating their flagella and concomitantly are aligned to magnetic fields because they present magnetosomes, which are intracellular organelles composed by membrane-bound magnetic crystals. This results in magnetotaxis, which is swimming along magnetic field lines. Magnetotactic bacteria are morphologically diverse, including cocci, rods, spirilla and multicellular forms known as magnetotactic multicellular prokaryotes (MMPs). 'Candidatus Magnetoglobus multicellularis' is presently the best known MMP. Here we describe the helical trajectories performed by these microorganisms as they swim forward, as well as their response to UV light. We measured the radius of the trajectory, time period and translational velocity (velocity along the helix axis), which enabled the calculation of other trajectory parameters such as pitch, tangential velocity (velocity along the helix path), angular frequency, and theta angle (the angle between the helix path and the helix axis). The data revealed that 'Ca. M. multicellularis' swims along elongated helical trajectories with diameters approaching the diameter of the microorganism. In addition, we observed that 'Ca. M. multicellularis' responds to UV laser pulses by swimming backwards, returning to forward swimming several seconds after the UV laser pulse. UV light from a fluorescence microscope showed a similar effect. Thus, phototaxis is used in addition to magnetotaxis in this microorganism.

  3. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Mazur, Thomas R.; Curcuru, Austen; Sona, Karl; Kashani, Rojano; Green, Olga; Ochoa, Laura; Mutic, Sasa; Zoberi, Imran; Li, H. Harold; Thomas, Maria A., E-mail: mthomas@radonc.wustl.edu

    2016-11-15

    Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

  4. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  5. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  6. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  7. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  8. Dynamic compensation temperature in the kinetic spin-1 Ising model in an oscillating external magnetic field on alternate layers of a hexagonal lattice

    International Nuclear Information System (INIS)

    Temizer, Umuet; Keskin, Mustafa; Canko, Osman

    2009-01-01

    The dynamic behavior of a two-sublattice spin-1 Ising model with a crystal-field interaction (D) in the presence of a time-varying magnetic field on a hexagonal lattice is studied by using the Glauber-type stochastic dynamics. The lattice is formed by alternate layers of spins σ=1 and S=1. For this spin arrangement, any spin at one lattice site has two nearest-neighbor spins on the same sublattice, and four on the other sublattice. The intersublattice interaction is antiferromagnetic. We employ the Glauber transition rates to construct the mean-field dynamical equations. Firstly, we study time variations of the average magnetizations in order to find the phases in the system, and the temperature dependence of the average magnetizations in a period, which is also called the dynamic magnetizations, to obtain the dynamic phase transition (DPT) points as well as to characterize the nature (continuous and discontinuous) of transitions. Then, the behavior of the total dynamic magnetization as a function of the temperature is investigated to find the types of the compensation behavior. Dynamic phase diagrams are calculated for both DPT points and dynamic compensation effect. Phase diagrams contain the paramagnetic (p) and antiferromagnetic (af) phases, the p+af and nm+p mixed phases, nm is the non-magnetic phase, and the compensation temperature or the L-type behavior that strongly depend on the interaction parameters. For D 0 >3.8275, H 0 is the magnetic field amplitude, the compensation effect does not appear in the system.

  9. Dynamic compensation temperature in the kinetic spin-1 Ising model in an oscillating external magnetic field on alternate layers of a hexagonal lattice

    Energy Technology Data Exchange (ETDEWEB)

    Temizer, Umuet [Department of Physics, Bozok University, 66100 Yozgat (Turkey); Keskin, Mustafa [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)], E-mail: keskin@erciyes.edu.tr; Canko, Osman [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)

    2009-10-15

    The dynamic behavior of a two-sublattice spin-1 Ising model with a crystal-field interaction (D) in the presence of a time-varying magnetic field on a hexagonal lattice is studied by using the Glauber-type stochastic dynamics. The lattice is formed by alternate layers of spins {sigma}=1 and S=1. For this spin arrangement, any spin at one lattice site has two nearest-neighbor spins on the same sublattice, and four on the other sublattice. The intersublattice interaction is antiferromagnetic. We employ the Glauber transition rates to construct the mean-field dynamical equations. Firstly, we study time variations of the average magnetizations in order to find the phases in the system, and the temperature dependence of the average magnetizations in a period, which is also called the dynamic magnetizations, to obtain the dynamic phase transition (DPT) points as well as to characterize the nature (continuous and discontinuous) of transitions. Then, the behavior of the total dynamic magnetization as a function of the temperature is investigated to find the types of the compensation behavior. Dynamic phase diagrams are calculated for both DPT points and dynamic compensation effect. Phase diagrams contain the paramagnetic (p) and antiferromagnetic (af) phases, the p+af and nm+p mixed phases, nm is the non-magnetic phase, and the compensation temperature or the L-type behavior that strongly depend on the interaction parameters. For D<2.835 and H{sub 0}>3.8275, H{sub 0} is the magnetic field amplitude, the compensation effect does not appear in the system.

  10. Anisotropic universal conductance fluctuations in disordered quantum wires with Rashba and Dresselhaus spin–orbit interaction and an applied in-plane magnetic field

    International Nuclear Information System (INIS)

    Scheid, Matthias; Adagideli, İnanç; Richter, Klaus; Nitta, Junsaku

    2009-01-01

    We investigate the transport properties of narrow quantum wires realized in disordered two-dimensional electron gases in the presence of k-linear Rashba and Dresselhaus spin–orbit interaction, and an applied in-plane magnetic field. Building on previous work (Scheid et al 2008 Phys. Rev. Lett. 101 266401), we find that in addition to the conductance, the universal conductance fluctuations also feature anisotropy with respect to the magnetic field direction. This anisotropy can be explained solely from the symmetries exhibited by the Hamiltonian as well as the relative strengths of the Rashba and Dresselhaus spin–orbit interaction and thus can be utilized to detect this ratio from purely electrical measurements

  11. Device for investigation of magnetic flux jumps in ribbon superconductors

    International Nuclear Information System (INIS)

    Andrianov, A.V.; Bashkirov, Yu.A.; Kremlev, M.G.

    1986-01-01

    A device for simulation of magnetic flux jumps in superconductors of conducting magnet sandwich-type windings super-applyed of a ribbon conductor is described. A superconducting magnet with a measuring cassetter are the main elements of the device. An external magnetic field is generated by a two-sectional superconducting magnet permitting to simulate the shape of the magnetic field characteristic for sandwich-type windings. Maximum radial component of the magnetic field is 2 T. Jumps of the magnetic flux are recorded by induction transducers and the magnetic field-by Hall trasducer. The effect of coating of standard metal on magnetic flux jumps in Nb 3 Sn base superconducting ribbon is considered

  12. ExternE: Externalities of energy Vol. 1. Summary

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1995-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase 1 was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes is underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  13. Externalities of fuel cycles 'ExternE' project. Summary report

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1994-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase I was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes are underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  14. 27Al Magic Angle Spinning–Nuclear Magnetic Resonance (MAS-NMR) Analyses Applied to Historical Mortars

    Czech Academy of Sciences Publication Activity Database

    Hanzlíček, Tomáš; Perná, Ivana; Brus, Jiří

    2013-01-01

    Roč. 7, č. 2 (2013), s. 153-164 ISSN 1558-3058 R&D Projects: GA AV ČR IAA300460702 Institutional research plan: CEZ:AV0Z30460519; CEZ:AV0Z40500505 Keywords : mortars * magic angle spinning –nuclear magnetic resonance (MAS-NMR) in solid state * alumina-silicates Subject RIV: DM - Solid Waste and Recycling Impact factor: 0.714, year: 2013 http://www.tandfonline.com/doi/abs/10.1080/15583058.2011.624253

  15. Influence of Distance and Illumination on Detection of Marks in Augmented Reality applied to Transcranial Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    José Soeiro

    2016-12-01

    Full Text Available The study was carried out while developing an Augmented Reality mobile application that represents 3D virtual models of the brain of a patient over the real image of the patient’s head. The main purpose of the application is to guide doctors during a non-invasive medical procedure called Transcranial Magnetic Stimulation that uses electromagnetic stimulation to treat neurological problems. The tracking of these markers have proven to be one of the more challenging components of such an application and we observe that lighting conditions and distance to the markers are two of the main factors that can influence their accurate recognition

  16. Retention and Separation Changes of Ternary and Quaternary Alkaloids from Chelidonium majus L. by TLC Under the Influence of External Magnetic Field.

    Science.gov (United States)

    Malinowska, Irena; Studziński, Marek; Malinowski, Henryk; Gadzikowska, Maria

    2017-01-01

    Thin layer techniques proved their usefulness in the analysis of plant extract material. Thanks to their low operation costs, high sample throughput and possibility to gather chromatographic data for the whole sample in a single act, they allowed to find, and in some cases identify, active ingredients often hidden in sophisticated plant extract matrices. It was also proved that the presence of a magnetic field changes the retention of some substances, and moreover changes the separation efficiency of chromatographic systems. In the presented experiment, retention, efficiency and separation abilities of TLC chromatographic systems for mixtures of alkaloids under the influence of magnetic field depending on inductivity of the magnetic field, the saturation of chromatographic chamber and quantity of chromatographed substances were investigated. The results obtained were tested on real plant extracts that revealed the ability of chromatography in a magnetic field for separation of ternary and quaternary alkaloids from Chelidonium majus L. Our experiments proved that the presence of magnetic field induction lines perpendicular to the chromatographic plate plane can influence the width and retention of chromatographed substances, and can be considered as a tool for separation adjustment of plant extracts containing ternary and quaternary alkaloids.

  17. Investigation of Di-ethylhexyl Phthalate Migration by Applying Magnetic Solid Phase Extraction Method Followed by GC-FID Determination

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-10-01

    Full Text Available Background and Objectives: The addition of plasticizers (mainly phthalates and adipates makes plastic flexible and popular for packaging, storing and preserving food, water, and so on. The most widely used plasticizer in food contact applications is di-ethylhexyl phthalate (DEHP though being suspected to have carcinogenic and estrogenic properties. The aim of this study is application of magnetic solid phase extraction as new absorbent for determination of DEHP in water samples by gas chromatography (GC. Materials and Methods: Important factors in extraction, separation and determination processes were optimized using the one-variable-at-a-time method. For optimization, all tests were performed two times. Figures of merit of the proposed method were evaluated. The amount of DEHP in some water samples was determined using the proposed method. Results: The results showed that the obtained chromatogram of extract was free of significant interference. The preservatives’ recoveries ranged from 91.6% to 102.2%. Limit of detection and limit of quantitation were 0.1 mg kg-1 and 0.3 µg L-1, respectively. Concentration of DEHP in the studied samples was in the range of N.D-2.3 µg L-1. Conclusions: The acceptable performance and reliability of the proposed method were demonstrated. Temperature and time were fount as the most effective parameters in migration of DEHP. Keywords: Di-ethylhexyl phthalate, Magnetic solid phase extraction, Migration, Gas chromatography

  18. Conformational changes of a single magnetic particle string within gels.

    Science.gov (United States)

    An, Hai-Ning; Groenewold, Jan; Picken, S J; Mendes, Eduardo

    2014-02-21

    Magnetorheological (MR) gels consist of micron sized magnetic particles inside a gel matrix. Before physical cross-linking, the suspension is subjected to a small magnetic field which creates a particle string structure. After cross-linking, the string is kept within the gel at room temperature. Under an external homogeneous magnetic field and mechanical deformation, the soft swollen gel matrix allows the string to largely rearrange at microscopic scales. With the help of two homemade magneto cells mounted on an optical microscope, we were able to follow the conformational change and instabilities of a single magnetic particle string under the combined influence of shear (or stretch) and the magnetic field. In the absence of mechanical deformation, an external magnetic field, applied in the perpendicular direction to the string, breaks it into small pieces generating periodic structures like sawteeth. When an external magnetic field is applied parallel to the pre-aligned string, it exhibits a length contraction. However, under shear strain perpendicular to the original pre-structured string (and magnetic field), the string breaks and short string segments tilt, making an angle with the original direction that is smaller than that of the applied shear (non-affine). The difference in tilt angle scales with the inverse length of the small segments L-1 and the magnetic flux density B, reflecting the ability of the gel matrix to expel solvents under local stress.

  19. Shaping magnetic fields to direct therapy to ears and eyes.

    Science.gov (United States)

    Shapiro, B; Kulkarni, S; Nacev, A; Sarwar, A; Preciado, D; Depireux, D A

    2014-07-11

    Magnetic fields have the potential to noninvasively direct and focus therapy to disease targets. External magnets can apply forces on drug-coated magnetic nanoparticles, or on living cells that contain particles, and can be used to manipulate them in vivo. Significant progress has been made in developing and testing safe and therapeutic magnetic constructs that can be manipulated by magnetic fields. However, we do not yet have the magnet systems that can then direct those constructs to the right places, in vivo, over human patient distances. We do not yet know where to put the external magnets, how to shape them, or when to turn them on and off to direct particles or magnetized cells-in blood, through tissue, and across barriers-to disease locations. In this article, we consider ear and eye disease targets. Ear and eye targets are too deep and complex to be targeted by a single external magnet, but they are shallow enough that a combination of magnets may be able to direct therapy to them. We focus on how magnetic fields should be shaped (in space and time) to direct magnetic constructs to ear and eye targets.

  20. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  1. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  2. Assembly of Superparamagnetic Filaments in External Field.

    Science.gov (United States)

    Wei, Jiachen; Song, Fan; Dobnikar, Jure

    2016-09-13

    We present a theoretical and simulation study of anchored magneto-elastic filaments in external magnetic field. The filaments are composed of a mixture of superparamagnetic and nonmagnetic colloidal beads interlinked with elastic springs. We explore the steady-state structures of filaments with various composition and bending rigidity subject to external magnetic field parallel to the surface. The interplay of elastic and induced magnetic interactions results in a rich phase behavior with morphologies reminiscent of macromolecular folding: bent filaments, loops, sheets, helicoids, and other collapsed structures. Our results provide new insights into the design of hierarchically assembled supramolecular structures with controlled response to external stimuli.

  3. Characterization of the magnetic micro- and nanostructure in unalloyed steels by magnetic force microscopy

    Science.gov (United States)

    Batista, L.; Rabe, U.; Hirsekorn, S.

    2013-01-01

    The formation of a cementite phase influences significantly the macroscopic mechanical and magnetic properties of steels. Based on a correlation between mechanical and magnetic properties, mechanical properties as well as the morphology and content of the cementite phase can be inspected by electromagnetic non-destructive testing methods. The influence of the carbon content on bulk magnetic properties of unalloyed steels is studied on a macroscopic scale by hysteresis loop and Barkhausen noise measurements. The micro- and nanostructure is investigated by atomic force microscopy and magnetic force microscopy. Surface topography images and magnetic images of globular cementite precipitates embedded in a ferrite matrix are presented. The size, shape, and orientation of the precipitates influence the domain configuration. Applied external magnetic fields cause magnetization processes mainly in the ferrite matrix: Bloch walls move and are pinned by the cementite precipitates. The correlation between the microscopic observations and macroscopic magnetic properties of the material is discussed.

  4. ExternE transport methodology for external cost evaluation of air pollution

    DEFF Research Database (Denmark)

    Jensen, S. S.; Berkowicz, R.; Brandt, J.

    The report describes how the human exposure estimates based on NERI's human exposure modelling system (AirGIS) can improve the Danish data used for exposure factors in the ExternE Transport methodology. Initially, a brief description of the ExternE Tranport methodology is given and it is summarised...... how the methodology has been applied so far in a previous Danish study. Finally, results of a case study are reported. Exposure factors have been calculated for various urban categories in the Greater Copenhagen Area...

  5. External magnetic field-mediated movement of brain nerve terminals labeled by D-mannose-coated gamma-Fe2O3 nano-sized particles

    Czech Academy of Sciences Publication Activity Database

    Borisova, T.; Krisanova, N.; Sivko, R.; Borysov, A.; Babič, Michal; Horák, Daniel

    2014-01-01

    Roč. 281, Supplement s1 (2014), s. 373 ISSN 1742-464X. [FEBS EMBO 2014 Conference. 30.08.2014-04.09.2014, Paris] Institutional support: RVO:61389013 Keywords : brain nerve terminals * glutamate transport * magnetic nanoparticles Subject RIV: CD - Macromolecular Chemistry http://onlinelibrary.wiley.com/doi/10.1111/febs.12919/abstract

  6. AC magnetization loss characteristics of HTS coated-conductors with magnetic substrates

    International Nuclear Information System (INIS)

    Tsukamoto, O.; Liu, M.; Odaka, S.; Miyagi, D.; Ohmatsu, K.

    2007-01-01

    AC magnetization loss characteristics of an HTS coated tape conductor with magnetic substrate subjected to an external AC magnetic field were investigated. The external magnetic field was perpendicular or parallel to the wide face of the tape conductor. Magnetization losses in the conductor and in the magnetic substrate itself without the superconductor layer, were measured by electric and calorimetric methods. The influence of the magnetic property of the substrate was strongly dependent on the direction of the external magnetic field. When the external magnetic field was perpendicular, magnetic property of the substrate did not affect the magnetization loss characteristics. This result suggests that the magnetization losses can be reduced by subdivisions of the superconducting layers even in the case of magnetic substrate conductors. When the external magnetic field was parallel, the magnetization losses were dominated by the losses in the magnetic substrate. Therefore, to reduce the magnetization losses in this case, reduction of magnetization losses in the substrate is necessary

  7. Magnetic Levitation.

    Science.gov (United States)

    Rossing, Thomas D.; Hull, John R.

    1991-01-01

    Discusses the principles of magnetic levitation presented in the physics classroom and applied to transportation systems. Topics discussed include three classroom demonstrations to illustrate magnetic levitation, the concept of eddy currents, lift and drag forces on a moving magnet, magnetic levitation vehicles, levitation with permanent magnets…

  8. Spin-torque oscillation in large size nano-magnet with perpendicular magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Linqiang, E-mail: LL6UK@virginia.edu [Department of Physics, University of Virginia, Charlottesville, VA 22904 (United States); Kabir, Mehdi [Department of Electrical & Computer Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Dao, Nam; Kittiwatanakul, Salinporn [Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Cyberey, Michael [Department of Electrical Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Wolf, Stuart A. [Department of Physics, University of Virginia, Charlottesville, VA 22904 (United States); Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Institute of Defense Analyses, Alexandria, VA 22311 (United States); Stan, Mircea [Department of Electrical & Computer Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Lu, Jiwei [Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States)

    2017-06-15

    Highlights: • 500 nm size nano-pillar device was fabricated by photolithography techniques. • A magnetic hybrid structure was achieved with perpendicular magnetic fields. • Spin torque switching and oscillation was demonstrated in the large sized device. • Micromagnetic simulations accurately reproduced the experimental results. • Simulations demonstrated the synchronization of magnetic inhomogeneities. - Abstract: DC current induced magnetization reversal and magnetization oscillation was observed in 500 nm large size Co{sub 90}Fe{sub 10}/Cu/Ni{sub 80}Fe{sub 20} pillars. A perpendicular external field enhanced the coercive field separation between the reference layer (Co{sub 90}Fe{sub 10}) and free layer (Ni{sub 80}Fe{sub 20}) in the pseudo spin valve, allowing a large window of external magnetic field for exploring the free-layer reversal. A magnetic hybrid structure was achieved for the study of spin torque oscillation by applying a perpendicular field >3 kOe. The magnetization precession was manifested in terms of the multiple peaks on the differential resistance curves. Depending on the bias current and applied field, the regions of magnetic switching and magnetization precession on a dynamical stability diagram has been discussed in details. Micromagnetic simulations are shown to be in good agreement with experimental results and provide insight for synchronization of inhomogeneities in large sized device. The ability to manipulate spin-dynamics on large size devices could be proved useful for increasing the output power of the spin-transfer nano-oscillators (STNOs).

  9. Transformation of the spectrum of TM polaritons of a 1D magnetic photonic crystal under conditions of the quadratic electro-optic effect

    International Nuclear Information System (INIS)

    Kulagin, D. V.; Savchenko, A. S.; Tarasenko, S. V.

    2008-01-01

    Conditions under which quadratic magneto-optical interaction leads to a number of features in the conditions of localization and propagation of collective magnetic TM polaritons are determined by the example of a 1D magnetic superlattice of the easy-axis-antiferromagnet-nonmagnetic-insulator type, in which the easy magnetization axis is orthogonal to the applied external dc electric field.

  10. Donor impurity binding energies of coaxial GaAs / Alx Ga1 - x As cylindrical quantum wires in a parallel applied magnetic field

    Science.gov (United States)

    Tshipa, M.; Winkoun, D. P.; Nijegorodov, N.; Masale, M.

    2018-04-01

    Theoretical investigations are carried out of binding energies of a donor charge assumed to be located exactly at the center of symmetry of two concentric cylindrical quantum wires. The intrinsic confinement potential in the region of the inner cylinder is modeled in any one of the three profiles: simple parabolic, shifted parabolic or the polynomial potential. The potential inside the shell is taken to be a potential step or potential barrier of a finite height. Additional confinement of the charge carriers is due to the vector potential of the axial applied magnetic field. It is found that the binding energies attain maxima in their variations with the radius of the inner cylinder irrespective of the particular intrinsic confinement of the inner cylinder. As the radius of the inner cylinder is increased further, the binding energies corresponding to either the parabolic or the polynomial potentials attain minima at some critical core-radius. Finally, as anticipated, the binding energies increase with the increase of the parallel applied magnetic field. This behaviour of the binding energies is irrespective of the particular electric potential of the nanostructure or its specific dimensions.

  11. Magnetic Nanotransducers in Biomedicine.

    Science.gov (United States)

    Grillone, Agostina; Ciofani, Gianni

    2017-11-16

    Owing to their abilities to identify diseased conditions, to modulate biological processes, and to control cellular activities, magnetic nanoparticles have become one of the most popular nanomaterials in the biomedical field. Targeted drug delivery, controlled drug release, hyperthermia treatment, imaging, and stimulation of several biological entities are just some of the several tasks that can be accomplished by taking advantage of magnetic nanoparticles in tandem with magnetic fields. The huge interest towards this class of nanomaterials arises from the possibility to physically drive their spatiotemporal localization inside the body, and to deliver an externally applied stimulation at a target site. They in fact behave as actual nanotransducers, converting energy stemming from the external magnetic field into heat and mechanical forces, which act as signals for therapeutic processes such as hyperthermia and controlled drug release. Magnetic nanoparticles are a noninvasive tool that enables the remote activation of biological processes, besides behaving as formidable tracers for different imaging modalities, thus allowing to simultaneously carry out diagnosis and therapy. In view of all this, owing to their multifunctional and multitasking nature, magnetic nanoparticles are already one of the most important nanotechnological protagonists in medicine and biology, enabling an actual theranostic approach in many pathological conditions. In this Concept, we first provide a brief introduction on some physical properties of magnetic materials and on important features that determine the physical properties of magnetic nanoparticles. Thereafter, we will consider some major biomedical applications: hyperthermia, drug delivery/release, and nanoparticle-mediated control of biological processes, even at subcellular level. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Structural, magnetic and superconducting phase transitions in CaFe2As2 under ambient and applied pressure

    International Nuclear Information System (INIS)

    Canfield, P.C.; Bud'ko, S.L.; Ni, N.; Kreyssig, A.; Goldman, A.I.; McQueeney, R.J.; Torikachvili, M.S.; Argyriou, D.N.; Luke, G.; Yu, W.

    2009-01-01

    At ambient pressure CaFe 2 As 2 has been found to undergo a first order phase transition from a high temperature, tetragonal phase to a low-temperature orthorhombic/antiferromagnetic phase upon cooling through T ∼ 170 K. With the application of pressure this phase transition is rapidly suppressed and by ∼0.35 GPa it is replaced by a first order phase transition to a low-temperature collapsed tetragonal, non-magnetic phase. Further application of pressure leads to an increase of the tetragonal to collapsed tetragonal phase transition temperature, with it crossing room temperature by ∼1.7 GPa. Given the exceptionally large and anisotropic change in unit cell dimensions associated with the collapsed tetragonal phase, the state of the pressure medium (liquid or solid) at the transition temperature has profound effects on the low-temperature state of the sample. For He-gas cells the pressure is as close to hydrostatic as possible and the transitions are sharp and the sample appears to be single phase at low temperatures. For liquid media cells at temperatures below media freezing, the CaFe 2 As 2 transforms when it is encased by a frozen media and enters into a low-temperature multi-crystallographic-phase state, leading to what appears to be a strain stabilized superconducting state at low temperatures.

  13. Magnetism of Lu.sub.2./sub.Fe.sub.17./sub.: The effects of Ru substitution, hydrogenation and external pressure

    Czech Academy of Sciences Publication Activity Database

    Tereshina, Evgeniya; Andreev, Alexander V.; Kamarád, Jiří; Drulis, H.

    2010-01-01

    Roč. 492, 1-2 (2010), s. 1-7 ISSN 0925-8388 R&D Projects: GA ČR GA202/09/0339; GA ČR GA202/09/1027 Institutional research plan: CEZ:AV0Z10100520; CEZ:AV0Z10100521 Keywords : rare-earth intermetallics * single crystals * ferromagnetism * hydrides * antiferromagnetism Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.138, year: 2010

  14. MAGNET

    CERN Multimedia

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  15. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  16. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  17. Network cities and externalities

    Directory of Open Access Journals (Sweden)

    Rafael Boix Domènech

    2004-01-01

    Full Text Available The concept of «agglomeration economies» explains the existence of advantages derived from the concentration of population and activity. However, it does not explain the existence of spatially dynamic external economies. Network economies generated in networks of cities correspond to this last type, since they are generated from the interaction between urban units, linked by a network relationship. The objective of this research is to advance in the study of the relationship between the networks of cities and the generation of external economies. The research is divided in four parts: first we expose the link between networks of cities and external economies. The second part outlines a model for the combined measuring of the concentration and network economies. The third part explains the results of applying the model to a case of study: the network of cities of Catalonia. The results suggest that there is a causal relationship between the organization of the urban units forming networks of cities and the generation of external economies that affect growth and economic development. Finally, conclusions and policy implications are drawn up.

  18. Controlling the magnetic field distribution on the micrometer scale and generation of magnetic bead patterns for microfluidic applications.

    Science.gov (United States)

    Yu, Xu; Feng, Xuan; Hu, Jun; Zhang, Zhi-Ling; Pang, Dai-Wen

    2011-04-19

    As is well known, controlling the local magnetic field distribution on the micrometer scale in a microfluidic chip is significant and has many applications in bioanalysis based on magnetic beads. However, it is a challenge to tailor the magnetic field introduced by external permanent magnets or electromagnets on the micrometer scale. Here, we demonstrated a simple approach to controlling the local magnetic field distribution on the micrometer scale in a microfluidic chip by nickel patterns encapsulated in a thin poly(dimethylsiloxane) (PDMS) film under the fluid channel. With the precisely controlled magnetic field, magnetic bead patterns were convenient to generate. Moreover, two kinds of fluorescent magnetic beads were patterned in the microfluidic channel, which demonstrated that it was possible to generate different functional magnetic bead patterns in situ, and could be used for the detection of multiple targets. In addition, this method was applied to generate cancer cell patterns. © 2011 American Chemical Society

  19. Automated External Defibrillator

    Science.gov (United States)

    ... To Health Topics / Automated External Defibrillator Automated External Defibrillator Also known as What Is An automated external ... in survival. Training To Use an Automated External Defibrillator Learning how to use an AED and taking ...

  20. The Evaluating of the possibility and adopting and applying of the international external auditing standards and it's suitability with the professional and legal environment in the State of Iraq

    Directory of Open Access Journals (Sweden)

    Fedaa Abd Almajid Sabbar Alaraji

    2017-12-01

    Full Text Available The external audit profession in Iraq suffers from problems and weakness in the profession, the most important of which is the of the profession of auditing system and monitoring auditing (external audit which is utilized in Iraq a now. And the failure to keep pace with developments and economic changes in the countries of the world, including Iraq, The current our study is aim to diagnosis and determine of most important of problems and Barriers which is suffer for it profession of external audit in Iraq. Our study is achieve many conclusions the most important,the suffering of the profession of external auditing in Iraq of many problems such as government intervention in the management of the profession, Also the study reached several recommendation and the most important work to develop the profession in Iraq based on international standards of external auditing which are considered guide for development.

  1. Promoting neuroregeneration by applying dynamic magnetic fields to a novel nanomedicine: Superparamagnetic iron oxide (SPIO)-gold nanoparticles bounded with nerve growth factor (NGF).

    Science.gov (United States)

    Yuan, Muzhaozi; Wang, Ya; Qin, Yi-Xian

    2018-04-05

    Neuroregeneration imposes a significant challenge in neuroscience for treating neurodegenerative diseases. The objective of this study is to evaluate the hypothesis that the nerve growth factor (NGF) functionalized superparamagnetic iron oxide (SPIO)-gold (Au) nanomedicine can stimulate the neuron growth and differentiation under external magnetic fields (MFs), and dynamic MFs outperform their static counterparts. The SPIO-Au core-shell nanoparticles (NPs) (Diameter: 20.8 nm) possessed advantages such as uniform quasi-spherical shapes, narrow size distribution, excellent stabilities, and low toxicity (viability >96% for 5 days). NGF functionalization has enhanced the cellular uptake. The promotion of neuronal growth and orientation using NGF functionalized SPIO-Au NPs, driven by both the static and dynamic MFs, were revealed experimentally on PC-12 cells and theoretically on a cytoskeletal force model. More importantly, dynamic MFs via rotation performed better than the static ones, i.e., the cellular differentiation ratio increased 58%; the neurite length elongation increased 63%. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Voltage control of a magnetization easy axis in piezoelectric/ferromagnetic hybrid films

    International Nuclear Information System (INIS)

    Kim, Sang-Koog; Lee, Jeong-Won; Shin, Sung-Chul; Song, Han Wook; Lee, Chang Ho; No, Kwangsoo

    2003-01-01

    We have established a spontaneous magnetization-axis switching in ferromagnetic films by applying a low voltage to a piezoelectric layer in a newly developed hybrid system comprised of the ferromagnetic and piezoelectric films. The magnetization easy axis along which a spontaneous magnetization is oriented, is readily switchable by a voltage without applying an external magnetic field through both the inverse magnetostrictive and piezoelectric effects of CoPd and lead-zirconate-titanate alloy films, respectively. This challenging work provides a new way into the memory writing as well as storage means of ultrahigh bit densities in nonvolatile magnetic random access memory

  3. Density functional theory-broken symmetry (DFT-BS) methodology applied to electronic and magnetic properties of bioinorganic prosthetic groups.

    Science.gov (United States)

    Mouesca, Jean-Marie

    2014-01-01

    The goal of this "how to" chapter is to present in a way as simple and practical as possible some of the concepts, key issues, and practices behind the so-called broken symmetry (BS) state which is widely used within the density functional theory (DFT) (for a very nice but thoughtful introduction to DFT (without equations!), read Perdew et al. (J Chem Theory Comput 5:902-908, 2009)) community to compute energetic as well as spectroscopic properties pertaining to (poly-)radicals, bioinorganic clusters (especially those containing transition metal ions), etc. Such properties encompass exchange coupling constants J (molecular magnetism) but also (among other things) g-tensors and hyperfine coupling tensors A (from electron paramagnetic resonance), isomer shifts δ and quadrupolar tensors ΔE Q (from Mössbauer), etc.Hopefully, this chapter will appeal to those DFT practitioners who would like to understand the basics behind the BS state and help them "demystify" some of the issues involved with them. More technical issues will only be alluded to, and appropriate references will be given for those interested to go beyond this mere introduction. This chapter is however not a review of the field. Consequently, it will be primarily based on my own experience. The goal here (in the spirit of a "how to" chapter) is to accompany the readers' thoughts in a progressive way along increasingly complex issues rather than encumbering the same thoughts with too complicate mathematical details (the few derivations which are given will therefore be explicit). Moreover, I will emphasize in this chapter the interplay between the computation of BS states on the one hand, and the derivation of phenomenological models on the other hand, whose parameters can be supplied from appropriate BS states. Finally, this chapter is dedicated to Louis Noodleman (Scripps Research Institute, CA, USA), pioneer (Noodleman, J Chem Phys 74:5737-5743, 1981; Noodleman, Chem Phys 109:131-143, 1986) and

  4. Study of the leakage field of magnetic force microscopy thin-film tips using electron holography

    NARCIS (Netherlands)

    Frost, B.G.; van Hulst, N.F.; Lunedei, E.; Matteucci, G.; Rikkers, E.

    1996-01-01

    Electron holography is applied for the study of the leakage field of thin-film ferromagnetic tips used as probes in magnetic force microscopy. We used commercially available pyramidal tips covered o­n o­ne face with a thin NiCo film, which were then placed in a high external magnetic field directed

  5. Self-assembly of spherical colloidal particles with off-centered magnetic dipoles

    NARCIS (Netherlands)

    Abrikosov, A.I.; Sacanna, S.; Philipse, A.P.; Linse, P.

    2013-01-01

    Fluids of spherical colloids possessing an off-centered embedded magnetic dipole were investigated by using Monte Carlo simulations. Systems of colloids with different strengths and directions of the embedded dipole moment confined in a 2D space without and with an external magnetic field applied

  6. Magnetic Fields Boosted by Gluon Vortices in Color Superconductivity

    International Nuclear Information System (INIS)

    Ferrer, Efrain J.; Incera, Vivian de la

    2006-01-01

    We investigate the effects of an external magnetic field in the gluon dynamics of a color superconductor with three massless quark flavors. In the framework of gluon mean-field theory at asymptotic densities, we show that the long-range component H(tilde sign) of the external magnetic field that penetrates the color-flavor locked phase produces an instability when its strength becomes larger than the Meissner mass of the charged gluons. As a consequence, the magnetic field causes the formation of a vortex state characterized by the condensation of charged gluons and the creation of magnetic flux tubes. Inside the flux tubes, the magnetic field is stronger than the applied one. This antiscreening effect is connected to the anomalous magnetic moment of the gluon field. We suggest how this same mechanism could serve to remove the chromomagnetic instabilities existing in gapless color superconductivity

  7. Pretreatment Endorectal Coil Magnetic Resonance Imaging Findings Predict Biochemical Tumor Control in Prostate Cancer Patients Treated With Combination Brachytherapy and External-Beam Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Riaz, Nadeem [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Afaq, Asim; Akin, Oguz [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Pei Xin; Kollmeier, Marisa A.; Cox, Brett [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Hricak, Hedvig [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2012-11-01

    Purpose: To investigate the utility of endorectal coil magenetic resonance imaging (eMRI) in predicting biochemical relapse in prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Methods and Materials: Between 2000 and 2008, 279 men with intermediate- or high-risk prostate cancer underwent eMRI of their prostate before receiving brachytherapy and supplemental intensity-modulated radiotherapy. Endorectal coil MRI was performed before treatment and retrospectively reviewed by two radiologists experienced in genitourinary MRI. Image-based variables, including tumor diameter, location, number of sextants involved, and the presence of extracapsular extension (ECE), were incorporated with other established clinical variables to predict biochemical control outcomes. The median follow-up was 49 months (range, 1-13 years). Results: The 5-year biochemical relapse-free survival for the cohort was 92%. Clinical findings predicting recurrence on univariate analysis included Gleason score (hazard ratio [HR] 3.6, p = 0.001), PSA (HR 1.04, p = 0.005), and National Comprehensive Cancer Network risk group (HR 4.1, p = 0.002). Clinical T stage and the use of androgen deprivation therapy were not correlated with biochemical failure. Imaging findings on univariate analysis associated with relapse included ECE on MRI (HR 3.79, p = 0.003), tumor size (HR 2.58, p = 0.04), and T stage (HR 1.71, p = 0.004). On multivariate analysis incorporating both clinical and imaging findings, only ECE on MRI and Gleason score were independent predictors of recurrence. Conclusions: Pretreatment eMRI findings predict for biochemical recurrence in intermediate- and high-risk prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Gleason score and the presence of ECE on MRI were the only significant predictors of biochemical relapse in this group of patients.

  8. Multiple blocks of intermittent and continuous theta-burst stimulation applied via transcranial magnetic stimulation differently affect sensory responses in rat barrel cortex.

    Science.gov (United States)

    Thimm, Andreas; Funke, Klaus

    2015-02-15

    Theta-burst stimulation (TBS) applied via transcranial magnetic stimulation is able to modulate human cortical excitability. Here we investigated in a rat model how two different forms of TBS, intermittent (iTBS) and continuous (cTBS), affect sensory responses in rat barrel cortex. We found that iTBS but less cTBS promoted late (>18 ms) sensory response components while not affecting the earliest response (8-18 ms). The effect increased with each of the five iTBS blocks applied. cTBS somewhat reduced the early response component after the first block but had a similar effect as iTBS after four to five blocks. We conclude that iTBS primarly modulates the activity of (inhibitory) cortical interneurons while cTBS may first reduce general neuronal excitability with a single block but reverse to iTBS-like effects with application of several blocks. Cortical sensory processing varies with cortical state and the balance of inhibition to excitation. Repetitive transcranial magnetic stimulation (rTMS) has been shown to modulate human cortical excitability. In a rat model, we recently showed that intermittent theta-burst stimulation (iTBS) applied to the corpus callosum, to activate primarily supragranular cortical pyramidal cells but fewer subcortical neurons, strongly reduced the cortical expression of parvalbumin (PV), indicating reduced activity of fast-spiking interneurons. Here, we used the well-studied rodent barrel cortex system to test how iTBS and continuous TBS (cTBS) modulate sensory responses evoked by either single or double stimuli applied to the principal (PW) and/or adjacent whisker (AW) in urethane-anaesthetized rats. Compared to sham stimulation, iTBS but not cTBS particularly enhanced late (>18 ms) response components of multi-unit spiking and local field potential responses in layer 4 but not the very early response (stimulation at 20 ms intervals. The effects increased with each of the five iTBS blocks applied. With cTBS a mild effect similar to

  9. Perspectives of optical lattices with state-dependent tunneling in approaching quantum magnetism in the presence of the external harmonic trapping potential

    International Nuclear Information System (INIS)

    Sotnikov, Andrii

    2016-01-01

    We study theoretically potential advantages of two-component mixtures in optical lattices with state-dependent tunneling for approaching long-range-order phases and detecting easy-axis antiferromagnetic correlations. While we do not find additional advantages of mixtures with large hopping imbalance for approaching quantum magnetism in a harmonic trap, it is shown that a nonzero difference in hopping amplitudes remains highly important for a proper symmetry breaking in the pseudospin space for the single-site-resolution imaging and can be advantageously used for a significant increase of the signal-to-noise ratio and thus detecting long-range easy-axis antiferromagnetic correlations in the corresponding experiments. - Highlights: • The most optimal ways to observe magnetic correlations in a quantum-gas microscope are presented. • Importance of a controlled symmetry breaking for antiferromagnetism is studied. • A quantitative theoretical analysis for the entropy in ultracold fermionic mixtures is performed. • No advantages from realizations with the strong hopping asymmetry are found.

  10. Analysis of the effect of locally applied inhomogeneous static magnetic field-exposure on mouse ear edema--a double blind study.

    Directory of Open Access Journals (Sweden)

    Balázs Kiss

    Full Text Available The effect static magnetic field (SMF-exposure may exert on edema development has been investigated. A 6 h long whole-body (WBSMF or local (LSMF, continuous, inhomogeneous SMF-exposure was applied on anesthetized mice in an in vivo model of mustard oil (MO-induced ear edema. LSMF was applied below the treated ear, below the lumbar spine, or below the mandible. Ear thickness (v was checked 8 times during the exposure period (at 0, 0.25, 1, 2, 3, 4, 5, and 6 h. The effect size of the applied treatment (η on ear thickness was calculated by the formula η = 100% × (1-v(j/v(i, where group i is the control group and j is the treated group. Results showed that MO treatment in itself induced a significant ear edema with an effect of 9% (p11% in both cases compared to SMF-exposure alone (p<0.001. In these cases SMF-exposure alone without MO treatment reduced ear thickness significantly (p<0.05, but within estimated experimental error. In cases of LSMF-exposure on the head, a significant SMF-exposure induced ear thickness reduction was found (η = 5%, p<0.05. LSMF-exposure on the spine affected ear thickness with and without MO treatment almost identically, which provides evidence that the place of local SMF action may be in the lower spinal region.

  11. Dynamic rheological properties of viscoelastic magnetic fluids in uniform magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Niu Xiaodong; Ye Xiaojiang; Li Mingjun; Iwamoto, Yuhiro

    2012-01-01

    The dynamic rheological properties of viscoelastic magnetic fluids in externally applied uniform magnetic fields are investigated by a laboratory-made cone-plate rheometer in this study. In particular, the effects of the magnetic field on the viscoelastic properties (the complex dynamic modulus) of the viscoelastic magnetic fluids are studied. In the investigation, three viscoelastic magnetic fluids are made by mixing a magnetic fluid and a viscoelastic fluid with different mass ratios. As a supplementation to the experimental investigation, a theoretical analysis is also presented. The present study shows that the viscosity and elasticity of the viscoelastic magnetic fluids are significantly influenced by the magnetic field and the concentrations of the magnetic particles in the test fluids. Theoretical analysis qualitatively explains the present findings. - Highlights: ► The dynamic rheological properties of the viscoelastic magnetic fluids in uniform magnetic fields are investigated. ► Both the magnetic field strength and the concentration of the magnetic particles in the fluids have significant effects on the viscosity and elasticity of the viscoelastic magnetic fluids. ► Theoretical prediction and analysis qualitatively explains the present findings.

  12. Development and test of model apparatus of non-contact spin processor for photo mask production applying radial-type superconducting magnetic bearing

    International Nuclear Information System (INIS)

    Saito, Kimiyo; Fukui, Satoshi; Maezawa, Masaru; Ogawa, Jun; Oka, Tetsuo; Sato, Takao

    2013-01-01

    Highlights: ► We develop test spinner for non-contact spinning process in photo mask production. ► This test spinner shows improved spinning ability compared with our previous one. ► Large vertical movement of turn table still occurs during acceleration. ► Method to control vertical movement of turn table should be developed in next step. -- Abstract: In semiconductor devices, miniaturization of circuit patterning on wafers is required for higher integrations of circuit elements. Therefore, very high tolerance and quality are also required for patterning of microstructures of photo masks. The deposition of particulate dusts generated from mechanical bearings of the spin processor in the patterns of the photo mask is one of main causes of the deterioration of pattern preciseness. In our R and D, application of magnetic bearing utilizing bulk high temperature superconductors to the spin processors has been proposed. In this study, we develop a test spinner for the non-contact spinning process in the photo mask production system. The rotation test by using this test spinner shows that this test spinner accomplishes the improvement of the spinning ability compared with the test spinner developed in our previous study. This paper describes the rotation test results of the new test spinner applying the magnetic bearing with bulk high temperature superconductors

  13. Effect of magnetic field on thermal conductivity and viscosity of a magnetic nanofluid loaded with carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Shahsavar, Amin [Kermanshah University of Technology, Kermanshah (Iran, Islamic Republic of); Salimpour, Mohammad Reza; Saghafian, Mohsen [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of); Shafii, M. B. [Sharif University of Technology, Tehran(Iran, Islamic Republic of)

    2016-02-15

    The present work examines experimentally the effect of magnetic field on the viscosity and thermal conductivity of a hybrid nanofluid containing tetramethylammonium hydroxide (TMAH) coated Fe{sub 3}O{sub 4} nanoparticles and Gum arabic (GA) coated carbon nanotubes (CNTs). The hybrid nanofluid was prepared by using ultrasonic dispersion method. Magnetic field was created by a pair of spaced apart magnet plates. The effect of temperature on the time variation of thermal conductivity under applied magnetic field was also investigated. According to the results of this study, viscosity of the hybrid nanofluid increases with the strength of magnetic field, while it decreases with the increase of temperature. Additionally, it is found that the hybrid nanofluid behaves as a shear thinning fluid at low shear rates while it exhibits Newtonian behavior at high shear rates. Furthermore, results show that when an external magnetic field is applied to the studied magnetic nanofluids, the thermal conductivity experiences a peak.

  14. Using magnetic coils to produce periodically applied forces to maintain the high speed movement of bodies and vehicles, particularly in tubes evacuated of air

    International Nuclear Information System (INIS)

    Pedrick, A.P.

    1976-01-01

    An arrangement is described in which a body is accelerated or maintained in motion along a track that passes through a number of annular electromagnet coils, the length of the body being substantially less than the distance between two adjacent coils. A series if electronmagnetically produced force pulses is applied to the body as it passes through successive coils, by the use of an automatic switch operated by the body. Control is provided so that each coil is de-energized at or before maximum magnetic flux linkage is attained between coil and body, the arrangement being such that the body is accelerated into the coil, but leaves it at a much reduced flux linkage. The possible uses of such an arrangement are mentioned: these include the acceleration of bullets, incorporating D and T in pellet form in their concave noses, to obtain a nuclear fusion reaction. (U.K.)

  15. Simulation of magnetic particles in microfluidic channels

    Science.gov (United States)

    Gusenbauer, Markus; Schrefl, Thomas

    2018-01-01

    In the field of biomedicine the applications of magnetic beads have increased immensely in the last decade. Drug delivery, magnetic resonance imaging, bioseparation or hyperthermia are only a small excerpt of their usage. Starting from microscaled particles the research is focusing more and more on nanoscaled particles. We are investigating and validating a method for simulating magnetic beads in a microfluidic flow which will help to manipulate beads in a controlled and reproducible manner. We are using the soft-matter simulation package ESPResSo to simulate magnetic particle dynamics in a lattice Boltzmann flow and applied external magnetic fields. Laminar as well as turbulent flow conditions in microfluidic systems can be analyzed while particles tend to agglomerate due to magnetic interactions. The proposed simulation methods are validated with experiments from literature.

  16. Development of a magnetic quartz crystal microbalance

    International Nuclear Information System (INIS)

    Yu, George Y.; Hunt, William D.; Josowicz, Mira; Janata, Jiri

    2007-01-01

    A new technique for measurement of magnetic properties of materials is demonstrated. It can be used for the measurement of thin magnetic films during their chemical modification. The resonance frequency of a quartz crystal microbalance (QCM) with conducting polymer (polyaniline) suspension in poly(ethylene glycol) was observed to increase with increasing the externally applied uniform dc magnetic field. Slowly sweeping the magnetic field between 0 and 3.1 T results in a frequency-field response curve. Chemical doping was done by exposing the polyaniline-emeraldine base film to HCl vapor. The change in population of free spins is reflected in increased frequency-field curve magnitude after HCl doping. Two working hypotheses explaining this observation are offered to explain how frequency of QCM with deposited magnetic film shifts with increasing intensity of the magnetic field

  17. Demagnetizing fields in active magnetic regenerators

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Bahl, Christian R.H.; Smith, Anders

    2014-01-01

    A magnetic material in an externally applied magnetic field will in general experience a spatially varying internal magnetic field due to demagnetizing effects. When the performance of active magnetic regenerators (AMRs) is evaluated using numerical models the internal field is often assumed...... is in general both a function of the overall shape of the regenerator and its morphology (packed particles, parallel plates etc.) as well as the magnetization of the material. Due to the pronounced temperature dependence of the magnetization near the Curie temperature, the demagnetization field is also...... temperature dependent. We propose a relatively straightforward method to correct sufficiently for the demagnetizing field in AMR models. We discuss how the demagnetizing field behaves in regenerators made of packed spheres under realistic operation conditions....

  18. A study of scaling and geometry effects on the forces between cuboidal and cylindrical magnets using analytical force solutions

    International Nuclear Information System (INIS)

    Agashe, Janhavi S; Arnold, David P

    2008-01-01

    Kelvin's formula is used to calculate forces acting on a permanent magnet in the presence of an external magnetic field from a second permanent magnet. This approach is used to derive explicit analytical solutions for the axial and lateral forces between cuboidal and cylindrical permanent magnets as functions of magnet dimensions and separation. While exact solutions can be found for cuboidal magnets, a hypergeometric expansion is used to approximate the elliptic integrals in solving for the fields and forces for the cylindrical magnets. The resulting equations are applied over a range of magnet sizes and geometries to explore scaling laws and other geometrical effects. It is shown that cuboidal magnets provide larger forces than equivalently sized cylindrical magnets. Also, the aspect ratio of the magnets significantly affects the forces. These results are intended to benefit the design and optimization of sensors, actuators and systems that rely on magnetic forces, particularly at the microscale

  19. Rashba and Dresselhaus spin-orbit couplings effects on electromagnetically induced transparency of a lens-shaped quantum dot: External electric and magnetic fields

    Science.gov (United States)

    Zamani, A.; Setareh, F.; Azargoshasb, T.; Niknam, E.; Mohammadhosseini, E.

    2017-06-01

    In this article the spin of electron as well as simultaneous effects of Rashba and Dresselhaus spin-orbit interactions are considered for a lens-shaped GaAs quantum dot and the influences of applied electric field and Zeeman effect on the electromagnetically induced transparency (EIT) of this system are investigated. To do so, the absorption, refractive index as well as the group velocity of the probe light pulse are presented and discussed. Study of the absorption and refractive index reveals that, at a particular frequency of probe field, absorption diminishes, refractive index becomes unity and so the EIT occurs. Furthermore, the investigation of group velocity show that, around such frequency the probe propagation is sub-luminal, which shifts to super-luminal for higher and lower frequencies. Our results illustrate that the EIT frequency, transparency window and sub(super)-luminal frequency intervals are strongly sensitive to applied fields in the presence of spin-orbit couplings. It is found that, in comparison with the investigations with negligence of spin, the EIT behavior under the effects of applied fields are quite different.

  20. Magnetic metallic multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Hood, Randolph Quentin [Univ. of California, Berkeley, CA (United States)

    1994-04-01

    Utilizing self-consistent Hartree-Fock calculations, several aspects of multilayers and interfaces are explored: enhancement and reduction of the local magnetic moments, magnetic coupling at the interfaces, magnetic arrangements within each film and among non-neighboring films, global symmetry of the systems, frustration, orientation of the various moments with respect to an outside applied field, and magnetic-field induced transitions. Magnetoresistance of ferromagnetic-normal-metal multilayers is found by solving the Boltzmann equation. Results explain the giant negative magnetoresistance encountered in these systems when an initial antiparallel arrangement is changed into a parallel configuration by an external magnetic field. The calculation depends on (1) geometric parameters (thicknesses of layers), (2) intrinsic metal parameters (number of conduction electrons, magnetization, and effective masses in layers), (3) bulk sample properties (conductivity relaxation times), (4) interface scattering properties (diffuse scattering versus potential scattering at the interfaces, and (5) outer surface scattering properties (specular versus diffuse surface scattering). It is found that a large negative magnetoresistance requires considerable asymmetry in interface scattering for the two spin orientations. Features of the interfaces that may produce an asymmetrical spin-dependent scattering are studied: varying interfacial geometric random roughness with no lateral coherence, correlated (quasi-periodic) roughness, and varying chemical composition of the interfaces. The interplay between these aspects of the interfaces may enhance or suppress the magnetoresistance, depending on whether it increases or decreases the asymmetry in the spin-dependent scattering of the conduction electrons.

  1. Magnetic metallic multilayers

    International Nuclear Information System (INIS)

    Hood, R.Q.

    1994-04-01

    Utilizing self-consistent Hartree-Fock calculations, several aspects of multilayers and interfaces are explored: enhancement and reduction of the local magnetic moments, magnetic coupling at the interfaces, magnetic arrangements within each film and among non-neighboring films, global symmetry of the systems, frustration, orientation of the various moments with respect to an outside applied field, and magnetic-field induced transitions. Magnetoresistance of ferromagnetic-normal-metal multilayers is found by solving the Boltzmann equation. Results explain the giant negative magnetoresistance encountered in these systems when an initial antiparallel arrangement is changed into a parallel configuration by an external magnetic field. The calculation depends on (1) geometric parameters (thicknesses of layers), (2) intrinsic metal parameters (number of conduction electrons, magnetization, and effective masses in layers), (3) bulk sample properties (conductivity relaxation times), (4) interface scattering properties (diffuse scattering versus potential scattering at the interfaces, and (5) outer surface scattering properties (specular versus diffuse surface scattering). It is found that a large negative magnetoresistance requires considerable asymmetry in interface scattering for the two spin orientations. Features of the interfaces that may produce an asymmetrical spin-dependent scattering are studied: varying interfacial geometric random roughness with no lateral coherence, correlated (quasi-periodic) roughness, and varying chemical composition of the interfaces. The interplay between these aspects of the interfaces may enhance or suppress the magnetoresistance, depending on whether it increases or decreases the asymmetry in the spin-dependent scattering of the conduction electrons

  2. Magnetism and high magnetic-field-induced stability of alloy carbides in Fe-based materials.

    Science.gov (United States)

    Hou, T P; Wu, K M; Liu, W M; Peet, M J; Hulme-Smith, C N; Guo, L; Zhuang, L

    2018-02-14

    Understanding the nature of the magnetic-field-induced precipitation behaviors represents a major step forward towards unravelling the real nature of interesting phenomena in Fe-based alloys and especially towards solving the key materials problem for the development of fusion energy. Experimental results indicate that the applied high magnetic field effectively promotes the precipitation of M 23 C 6 carbides. We build an integrated method, which breaks through the limitations of zero temperature and zero external field, to concentrate on the dependence of the stability induced by the magnetic effect, excluding the thermal effect. We investigate the intimate relationship between the external field and the origins of various magnetics structural characteristics, which are derived from the interactions among the various Wyckoff sites of iron atoms, antiparallel spin of chromium and Fe-C bond distances. The high-magnetic-field-induced exchange coupling increases with the strength of the external field, which then causes an increase in the parallel magnetic moment. The stability of the alloy carbide M 23 C 6 is more dependent on external field effects than thermal effects, whereas that of M 2 C, M 3 C and M 7 C 3 is mainly determined by thermal effects.

  3. Proposal of a methodology to be applied for the characterization of external exposure risk of employees in nuclear medicine services; Proposta de uma metodologia para caracterizacao de risco de exposicao externa de funcionarios de servicos de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Simoes, Rafael Figueiredo Pohlmann

    2010-07-01

    Nuclear medicine procedure requires the administration of radioactive material by injection, ingestion or inhalation. After incorporation, the patient becomes a mobile source of radiation and, after their examination; they can irradiate everyone on their way out of the Nuclear Medicine Service (NMS). A group of workers in this path is considered a critical group, but there are no conviction on this classification, because there are not measurements available. Thus, workers claiming for occupationally exposed individual's (OEI) rights are common. Employers are always in a complex situation, because if they decided to undertake the individual external monitoring of the critical working groups, the Court considers all as OEI and employers are taxed. On the other hand, if they do not provide monitoring, it is impossible to prove that these workers were not exposed to effective doses higher than individual annual public's limit and they lose the actions, too. This work proposes a methodology to evaluate, using TLD environmental monitors, air kerma rate at critical staff points in a NMS. This method provides relevant information about critical groups' exposure. From these results, the clinic or hospital may prove technically, without individual monitoring of employees, the classification of areas and can estimate the maximum flow of patients in the free areas which guarantees exposures below the public individual dose limit. This methodology has been applied successfully to a private clinic in Rio de Janeiro, which operates a NMS. The only critical group that received exposure statistically different from clinic background radiation was that on the antechamber of the NMS. This is a site that should be characterized as a supervised area and the group of workers in this environment as OEI, as the estimated extrapolated annual effective dose in this position was 1.2 +- 0.7 mSv/year, above the public annual limit (1,0 mSv/year). Normalizing by the number of

  4. Magnetically driven rotation of thermal plasma jet for non-degradable CF{sub 4} treatment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sooseok, E-mail: choi@chemenv.titech.ac.jp [Department of Nuclear Engineering, Seoul National University (Korea, Republic of); Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology (Japan); Hong, Sang Hee; Kim, Sungwoo [Department of Nuclear Engineering, Seoul National University (Korea, Republic of); Park, Dong-Wha [Department of Chemical Engineering and Regional Innovation Center for Environmental Technology of Thermal Plasma, Inha University (Korea, Republic of); Watanabe, Takayuki [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology (Japan)

    2012-11-15

    Effects of an externally applied magnetic field on the thermal plasma treatment of non-degradable greenhouse gas were investigated. Tetrafluoromethane (CF{sub 4}) was decomposed as a waste gas, because it is the most stable species among perfluorocompounds and has the highest global warming potential. A permanent magnet equipped on the exit region of a hollow electrode plasma torch produced azimuthal Lorentz force to drive rotational motions of the arc root and the thermal plasma jet. In order to sustain a stable arc discharge, the position of the permanent magnet was determined by numerical analysis on the temperature distribution according to the length of arc column. Forcibly swirling motion of thermal plasma jet was observed in accordance with the strength of applied magnetic field. Increased destruction and removal efficiency of CF{sub 4} was measured in torch operation with the externally applied magnetic field due to the enhanced entrainment of waste gas into the thermal plasma jet.

  5. Magnetically driven rotation of thermal plasma jet for non-degradable CF4 treatment

    International Nuclear Information System (INIS)

    Choi, Sooseok; Hong, Sang Hee; Kim, Sungwoo; Park, Dong-Wha; Watanabe, Takayuki

    2012-01-01

    Effects of an externally applied magnetic field on the thermal plasma treatment of non-degradable greenhouse gas were investigated. Tetrafluoromethane (CF 4 ) was decomposed as a waste gas, because it is the most stable species among perfluorocompounds and has the highest global warming potential. A permanent magnet equipped on the exit region of a hollow electrode plasma torch produced azimuthal Lorentz force to drive rotational motions of the arc root and the thermal plasma jet. In order to sustain a stable arc discharge, the position of the permanent magnet was determined by numerical analysis on the temperature distribution according to the length of arc column. Forcibly swirling motion of thermal plasma jet was observed in accordance with the strength of applied magnetic field. Increased destruction and removal efficiency of CF 4 was measured in torch operation with the externally applied magnetic field due to the enhanced entrainment of waste gas into the thermal plasma jet.

  6. Cervical cancer outcome prediction to high-dose rate brachytherapy using quantitative magnetic resonance imaging analysis of tumor response to external beam radiotherapy

    International Nuclear Information System (INIS)

    Minkoff, David; Gill, Beant S.; Kang, John; Beriwal, Sushil

    2015-01-01

    Background and purpose: In order to assess tumor regression and outcomes, a volumetric analysis was conducted for cervical cancer patients treated with magnetic resonance imaging (MRI)-based image-guided brachytherapy (IGBT). Materials and methods: Consecutive patients with FIGO stage IB1–IVA cervical cancer receiving chemoradiation from 2007 to 2013 were identified, excluding patients with perineal template-based interstitial brachytherapy or without undergoing MRI. A ring and tandem applicator ± interstitial needles was used. T2-weighted imaging was completed following applicator insertion. Gross tumor volumes (GTVs) were retrospectively contoured: initial GTV (GTV Pre-EBRT ), GTV at first brachytherapy (GTV IGBT ) and percent residual GTV at first brachytherapy (% GTV Residual ). Results: Eighty-four patients were identified. With 20.8-month median follow-up, two-year estimates of local control (LC), disease-free survival (DFS) and overall survival (OS) were 91.3, 79.8, and 85.0%, respectively. Multivariate Cox regression revealed adenocarcinoma (HR 5.88, p = 0.03) and GTV IGBT (HR 1.17, p < 0.01) as predictors for local failure. GTV IGBT > 7.5 cc was associated with inferior 2-year LC (75.0 vs. 96.6%, p < 0.01), DFS (42.6 vs. 91.6%, p < 0.01) and OS (65.2 vs. 91.5%, p < 0.01). No difference in mean HRCTV D 90 EQD 2 was seen between the groups (p = 0.61). Conclusion: Aside from known benefits of IGBT, MRI-based planning allows for assessment of tumor regression and prognosticates patients

  7. Experimental Confirmation of Nonlinear-Model- Predictive Control Applied Offline to a Permanent Magnet Linear Generator for Ocean-Wave Energy Conversion

    KAUST Repository

    Tom, Nathan

    2015-01-01

    To further maximize power absorption in both regular and irregular ocean wave environments, nonlinear-model-predictive control (NMPC) was applied to a model-scale point absorber developed at the University of California Berkeley, Berkeley, CA, USA. The NMPC strategy requires a power-takeoff (PTO) unit that could be turned on and off, as the generator would be inactive for up to 60% of the wave period. To confirm the effectiveness of this NMPC strategy, an in-house-designed permanent magnet linear generator (PMLG) was chosen as the PTO. The time-varying performance of the PMLG was first characterized by dry-bench tests, using mechanical relays to control the electromagnetic conversion process. The on/off sequencing of the PMLG was tested under regular and irregular wave excitation to validate NMPC simulations using control inputs obtained from running the choice optimizer offline. Experimental results indicate that successful implementation was achieved and absorbed power using NMPC was up to 50% greater than the passive system, which utilized no controller. Previous investigations into MPC applied to wave energy converters have lacked the experimental results to confirm the reported gains in power absorption. However, after considering the PMLG mechanical-to-electrical conversion efficiency, the electrical power output was not consistently maximized. To improve output power, a mathematical relation between the efficiency and damping magnitude of the PMLG was inserted in the system model to maximize the electrical power output through continued use of NMPC which helps separate this work from previous investigators. Of significance, results from latter simulations provided a damping time series that was active over a larger portion of the wave period requiring the actuation of the applied electrical load, rather than on/off control.

  8. Effects of scanning and reconstruction parameters on image quality in magnetic particle imaging

    OpenAIRE

    Bozkurt, Ecem

    2018-01-01

    Cataloged from PDF version of article. Thesis (M.S.): Bilkent University, Department of Electrical and Electronics Engineering, İhsan Doğramacı Bilkent University, 2018. Includes bibliographical references (leaves 55-59). Magnetic particle imaging (MPI) is a novel medical imaging modality, based on the magnetization of the superparamagnetic iron oxide nanoparticles. In MPI, an external magnetic field called the drive field is applied to excite the nanoparticles. The link bet...

  9. William Brinkman (centre), Director of the Department of Energy, U.S.A. at the superconducting magnet test hall SM18 with (from left to right) Coordinator for External Relations F. Pauss, Advisor for Non-Member States J. Ellis, J. Strait from Fermilab and Deputy Head of Technology Department L. Rossi on 13 November 2009.

    CERN Multimedia

    Maximilien Brice; SM18

    2009-01-01

    William Brinkman (centre), Director of the Department of Energy, U.S.A. at the superconducting magnet test hall SM18 with (from left to right) Coordinator for External Relations F. Pauss, Advisor for Non-Member States J. Ellis, J. Strait from Fermilab and Deputy Head of Technology Department L. Rossi on 13 November 2009.

  10. 20th May 2010 - Malaysian Minister for Science, Technology and Innovation H. F: B. H. Yusof signing the guest book with Coordinator for External Relations F. Pauss and CMS Collaboration Deputy Spokesperson A. De Roeck; visiting the LHC superconducting magnet test hall with Technology Department Head F. Bordry; throughout accompanied by CERN Advisers J. Ellis and E. Tsesmelis.

    CERN Document Server

    Maximilien brice

    2010-01-01

    20th May 2010 - Malaysian Minister for Science, Technology and Innovation H. F: B. H. Yusof signing the guest book with Coordinator for External Relations F. Pauss and CMS Collaboration Deputy Spokesperson A. De Roeck; visiting the LHC superconducting magnet test hall with Technology Department Head F. Bordry; throughout accompanied by CERN Advisers J. Ellis and E. Tsesmelis.

  11. Observation of Various and Spontaneous Magnetic Skyrmionic Bubbles at Room Temperature in a Frustrated Kagome Magnet with Uniaxial Magnetic Anisotropy

    KAUST Repository

    Hou, Zhipeng

    2017-06-07

    The quest for materials hosting topologically protected skyrmionic spin textures continues to be fueled by the promise of novel devices. Although many materials have demonstrated the existence of such spin textures, major challenges remain to be addressed before devices based on magnetic skyrmions can be realized. For example, being able to create and manipulate skyrmionic spin textures at room temperature is of great importance for further technological applications because they can adapt to various external stimuli acting as information carriers in spintronic devices. Here, the first observation of skyrmionic magnetic bubbles with variable topological spin textures formed at room temperature in a frustrated kagome Fe3 Sn2 magnet with uniaxial magnetic anisotropy is reported. The magnetization dynamics are investigated using in situ Lorentz transmission electron microscopy, revealing that the transformation between different magnetic bubbles and domains is via the motion of Bloch lines driven by an applied external magnetic field. These results demonstrate that Fe3 Sn2 facilitates a unique magnetic control of topological spin textures at room temperature, making it a promising candidate for further skyrmion-based spintronic devices.

  12. Study on propagation properties of laser guiding EMP in a finite magnetic field

    International Nuclear Information System (INIS)

    Xia Xinren; Yin Chengyou

    2009-01-01

    The geometric model of laser plasma channel (LPC) guiding electromagnetic pulse (EMP) in a finite electromagnetic field is created; when LPC is in lossy gas the propagation properties of the normal modes of LPC guiding EMP are studied; and then the wave equation of longitudinal electormagnetic field and the relationship between transverse and longitudinal electromagnetic field in anisotropic medium are derived under the generalized cylindrical coordinate system. By applying the boundary conditions of electromagnetic fields, the strict characteristic equation of mode propagation for LPC guiding EMP is deduced, and the effects of plasma parameters, surrounding material and external magnetic field on propagation are discussed. The results show that the propagation properties of magnetized LPC guiding EMP are easy to be controlled compared with those without external magnetic field or an infinite external magnetic field applied. (authors)

  13. Effect of applied tensile stress on the hysteresis curve and magnetic domain structure of grain-oriented transverse Fe-3%Si steel

    Czech Academy of Sciences Publication Activity Database

    Perevertov, Oleksiy; Thielsch, J.; Schäfer, R.

    2015-01-01

    Roč. 385, Jul (2015), 358-367 ISSN 0304-8853 R&D Projects: GA ČR GA13-18993S Institutional support: RVO:68378271 Keywords : magnetic domains * magnetization process * magnetoelasticity * hysteresis loops * tension * Kerr microscopy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.357, year: 2015

  14. Highly tunable perpendicularly magnetized synthetic antiferromagnets for biotechnology applications

    OpenAIRE

    Vemulkar, T; Mansell, Rhodri; Petit, Dorothee Celine; Cowburn, Russell Paul; Lesniak, MS

    2015-01-01

    Magnetic micro and nanoparticles are increasingly used in biotechnological applications due to the ability to control their behavior through an externally applied field. We demonstrate the fabrication of particles made from ultrathin perpendicularly magnetized CoFeB/Pt layers with antiferromagnetic interlayer coupling. The particles are characterized by zero moment at remanence, low susceptibility at low fields, and a large saturated moment created by the stacking of the basic coupled bilayer...

  15. Mach-Zehnder interferometer by utilizing phase modulation of transmitted light through magnetic fluid films possessing tunable refractive index

    International Nuclear Information System (INIS)

    Hong, C.-Y.; Yang, S.Y.; Fang, K.L.; Horng, H.E.; Yang, H.C.

    2006-01-01

    Due to its diverse applications in photonics, bio-sensors, mechanics, etc., Mach-Zehnder interferometer becomes one of important devices. Hence, lots of efforts have been paid to develop advanced Mach-Zehnder interferometers. In this work, we explore new-model Mach-Zehnder interferometer, in which one of arm is consisted of magnetic fluid films. By utilizing the tunable refractive index of magnetic fluid films under external magnetic fields, the traveling phase of a propagating light through the magnetic fluid film is changed. This could lead to a variation in the interfered intensity of the Mach-Zehnder interferometer when an external magnetic field is applied. The modulation in the interfered intensity by the external magnetic field is demonstrated experimentally, and the relevant physical origin is also discussed

  16. Magnetic properties in BaFe12O19 nanoparticles prepared under a magnetic field

    International Nuclear Information System (INIS)

    Wang Jun; Chen Qianwang; Che Shan

    2004-01-01

    It was observed that the nanocrystallites of BaFe 12 O 19 formed at 140 deg. C under a 0.25 T magnetic field exhibited a higher saturation magnetization (6.1 emu/g at room temperature) than that of the sample (1.1 emu/g) obtained under zero magnetic field. Both of the two approaches yielded plain-like particles with an average particle size of 12 nm. However, the Curie temperature (T c ), a direct measuring of the strength of superexchange interaction of Fe 3+ -O 2- -Fe 3+ , increased from 410 deg. C for the nanoparticles prepared without an external field applied to 452 deg. C for the particles formed under a 0.25 T magnetic field, which indicates that external magnetic fields can improve the occupancy of magnetic ions and then increase the superexchange interaction. This was confirmed by electron paramagnetic resonance and Moessbauer spectrum analysis. The results present in this paper suggest that in addition to oxygen defects, surface non-magnetic layer and a fraction of finer particles in the superparamagnetic range, cation vacancies should be responsible for the decreasing of saturation magnetization in magnetic nanoparticles

  17. Internal and External Readings of Same

    DEFF Research Database (Denmark)

    Hardt, Daniel

    2016-01-01

    is infelicitous in the absence of parallelism. Hardt and Mikkelsen propose an account that applies uniformly to internal and external readings; however, the evidence they present largely targets external readings – they don’t offer empirical evidence that clearly supports the uniform approach. Furthermore, Barker...... (2007) argues that internal readings must be treated differently than external readings. In this paper, I show that the parallelism effects observed by Hardt and Mikkelsen in fact apply to internal readings as well. This provides support for a uniform treatment of internal and external readings of same...

  18. A ferrofluid based artificial tactile sensor with magnetic field control

    International Nuclear Information System (INIS)

    Volkova, T.I.; Böhm, V.; Naletova, V.A.; Kaufhold, T.; Becker, F.; Zeidis, I.; Zimmermann, K.

    2017-01-01

    The paper deals with a tactile sensor inspired by biological hairs of mammals. The working principle is based on the effect of the magnetic force exerted on a paramagnetic body submerged into a ferrofluid volume under the influence of a nonuniform magnetic field. The deflection of the sensor's rod caused by external mechanical stimuli may be unambiguously identified by the distortion of the magnetic field, which occurs due to the motion of the attached body in the ferrofluid. The magnetic force acting on the body is evaluated experimentally and theoretically for the nonuniform magnetic field of a permanent magnet. The controlled oscillations of the rod are realised by applying a nonuniform magnetic field of periodically altering direction. - Highlights: • A design approach of a tactile sensor inspired by special mammalian hairs is presented. • The working principle is based on magnetic properties of a ferrofluid in magnetic fields. • The magnetic force acting on a body submerged into a ferrofluid volume is evaluated. • External mechanical stimuli may be identified by the distortion of the magnetic field. • The controlled whisking-like oscillations of the sensor's rod are realised experimentally.

  19. A ferrofluid based artificial tactile sensor with magnetic field control

    Energy Technology Data Exchange (ETDEWEB)

    Volkova, T.I., E-mail: tatiana.volkova@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany); Böhm, V., E-mail: valter.boehm@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany); Naletova, V.A., E-mail: naletova@imec.msu.ru [Faculty of Mechanics and Mathematics, Lomonosov Moscow State University, 119991 Moscow (Russian Federation); Kaufhold, T., E-mail: tobias.kaufhold@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany); Becker, F., E-mail: felix.becker@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany); Zeidis, I., E-mail: igor.zeidis@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany); Zimmermann, K., E-mail: klaus.zimmermann@tu-ilmenau.de [Technical Mechanics Group, Faculty of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau D-98684 (Germany)

    2017-06-01

    The paper deals with a tactile sensor inspired by biological hairs of mammals. The working principle is based on the effect of the magnetic force exerted on a paramagnetic body submerged into a ferrofluid volume under the influence of a nonuniform magnetic field. The deflection of the sensor's rod caused by external mechanical stimuli may be unambiguously identified by the distortion of the magnetic field, which occurs due to the motion of the attached body in the ferrofluid. The magnetic force acting on the body is evaluated experimentally and theoretically for the nonuniform magnetic field of a permanent magnet. The controlled oscillations of the rod are realised by applying a nonuniform magnetic field of periodically altering direction. - Highlights: • A design approach of a tactile sensor inspired by special mammalian hairs is presented. • The working principle is based on magnetic properties of a ferrofluid in magnetic fields. • The magnetic force acting on a body submerged into a ferrofluid volume is evaluated. • External mechanical stimuli may be identified by the distortion of the magnetic field. • The controlled whisking-like oscillations of the sensor's rod are realised experimentally.

  20. Autoregressive moving average (ARMA) model applied to quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murase, Kenya; Yamazaki, Youichi; Shinohara, Masaaki

    2003-01-01

    The purpose of this study was to investigate the feasibility of the autoregressive moving average (ARMA) model for quantification of cerebral blood flow (CBF) with dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) in comparison with deconvolution analysis based on singular value decomposition (DA-SVD). Using computer simulations, we generated a time-dependent concentration of the contrast agent in the volume of interest (VOI) from the arterial input function (AIF) modeled as a gamma-variate function under various CBFs, cerebral blood volumes and signal-to-noise ratios (SNRs) for three different types of residue function (exponential, triangular, and box-shaped). We also considered the effects of delay and dispersion in AIF. The ARMA model and DA-SVD were used to estimate CBF values from the simulated concentration-time curves in the VOI and AIFs, and the estimated values were compared with the assumed values. We found that the CBF value estimated by the ARMA model was more sensitive to the SNR and the delay in AIF than that obtained by DA-SVD. Although the ARMA model considerably overestimated CBF at low SNRs, it estimated the CBF more accurately than did DA-SVD at high SNRs for the exponential or triangular residue function. We believe this study will contribute to an understanding of the usefulness and limitations of the ARMA model when applied to quantification of CBF with DSC-MRI. (author)

  1. Recent Advances in Magnetic Microfluidic Biosensors

    Directory of Open Access Journals (Sweden)

    Ioanna Giouroudi

    2017-07-01

    Full Text Available The development of portable biosening devices for the detection of biological entities such as biomolecules, pathogens, and cells has become extremely significant over the past years. Scientific research, driven by the promise for miniaturization and integration of complex laboratory equipment on inexpensive, reliable, and accurate devices, has successfully shifted several analytical and diagnostic methods to the submillimeter scale. The miniaturization process was made possible with the birth of microfluidics, a technology that could confine, manipulate, and mix very small volumes of liquids on devices integrated on standard silicon technology chips. Such devices are then directly translating the presence of these entities into an electronic signal that can be read out with a portable instrumentation. For the aforementioned tasks, the use of magnetic markers (magnetic particles—MPs—functionalized with ligands in combination with the application of magnetic fields is being strongly investigated by research groups worldwide. The greatest merits of using magnetic fields are that they can be applied either externally or from integrated microconductors and they can be well-tuned by adjusting the applied current on the microconductors. Moreover, the magnetic markers can be manipulated inside microfluidic channels by high gradient magnetic fields that can in turn be detected by magnetic sensors. All the above make this technology an ideal candidate for the development of such microfluidic biosensors. In this review, focus is given only to very recent advances in biosensors that use microfluidics in combination with magnetic sensors and magnetic markers/nanoparticles.

  2. Functional magnetic nanoparticles for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Ichiyanagi, Yuko [Graduate School of Engineering, Department of Physics, Yokohama National University, Yokohama 240-8501 (Japan)]. E-mail: yuko@ynu.ac.jp; Moritake, Shinji [Graduate School of Engineering, Department of Physics, Yokohama National University, Yokohama 240-8501 (Japan); Taira, Shu [Mitsubishi Kagaku Institute of Life Sciences, Molecular Gerontology Research Group, Tokyo 194-8511 (Japan); Setou, Mitsutoshi [Mitsubishi Kagaku Institute of Life Sciences, Molecular Gerontology Research Group, Tokyo 194-8511 (Japan)

    2007-03-15

    We prepared an amino-substituted nanoparticle by means of the amino-silane coupling procedure. The original magnetic particles were {gamma}-Fe{sub 2}O{sub 3}, which ranged in size from 1.3 to 34 nm, surrounded by amorphous SiO{sub 2}. The modification of the magnetic particle by the addition of an amino group was confirmed using a Fourier transform infrared spectrophotometer (FT-IR). The X-ray diffraction patterns showed a spinel structure both before and after modification of the amino group. The magnetization curve indicated paramagnetic behavior for the 3 nm particles, superparamagnetic behavior for the 7 nm particles, and ferromagnetic behavior for 9 nm particles at room temperature. A fluorescent reagent was applied to the particle, and the particle was introduced into a cell. The magnetic particles in the cell were localized using an external magnetic field.

  3. Functional magnetic nanoparticles for medical application

    International Nuclear Information System (INIS)

    Ichiyanagi, Yuko; Moritake, Shinji; Taira, Shu; Setou, Mitsutoshi

    2007-01-01

    We prepared an amino-substituted nanoparticle by means of the amino-silane coupling procedure. The original magnetic particles were γ-Fe 2 O 3 , which ranged in size from 1.3 to 34 nm, surrounded by amorphous SiO 2 . The modification of the magnetic particle by the addition of an amino group was confirmed using a Fourier transform infrared spectrophotometer (FT-IR). The X-ray diffraction patterns showed a spinel structure both before and after modification of the amino group. The magnetization curve indicated paramagnetic behavior for the 3 nm particles, superparamagnetic behavior for the 7 nm particles, and ferromagnetic behavior for 9 nm particles at room temperature. A fluorescent reagent was applied to the particle, and the particle was introduced into a cell. The magnetic particles in the cell were localized using an external magnetic field

  4. Experiments in Ice Contaminant Remanent Magnetization of Dusty Frost Deposits

    Science.gov (United States)

    Grossman, Y.; Aharonson, O.; Shaar, R.

    2017-12-01

    Sedimentary rocks can acquire magnetization in the presence of an external field as grains settle out of suspension in a water column - a process known as Depositional Remanent Magnetization (DRM). In analogy with this, here we propose and experimentally demonstrate a new mechanism for acquisition of magnetization by ice and particulate mixtures which we term Ice Contaminant Remanent Magnetization (ICRM). This phenomenon results from the settling of atmospheric dust containing magnetic particles (e.g. magnetite or other iron oxides). Upon freezing, magnetic dust particles assume a preferential orientation that depends on the external planetary field, resulting in bulk magnetization of the dusty ice. Hence over geologic timescales, the ice stratigraphy is expected to record the geomagnetic history. To test this hypothesis, we designed a set of experiments in which mixtures of ice and dust were deposited in a controlled ambient magnetic field environment. We measured the ratio between the volume normalized magnetization of the dusty ice (m) and the applied field (H) during deposition of the mixture, which is expressed as the effective ICRM susceptibility: m=χICRMH. A magnetic field was applied by a 3-axis Helmholtz coil at the Weizmann Simulating Planetary Ices & Environments Laboratory, and the frozen samples were analyzed in a 2G-Entreprises SQUID Rock Magnetometer at the Hebrew University Institute for Earth Sciences. We measured a clear correlation in amplitude and direction between the ambient magnetic field applied during deposition and the remanent magnetic moment of the resulting samples. We studied various concentrations and particle sizes (diameters 5 µm to 50 µm) of iron and magnetite particles. Effective bulk susceptibilities show a range of values, starting from 10-3 and up to values that saturate the analytical instrument. Our preliminary results indicate that natural ice deposits may acquire variable magnetization due to ICRM, which may in turn be

  5. A ferrofluid based artificial tactile sensor with magnetic field control

    Science.gov (United States)

    Volkova, T. I.; Böhm, V.; Naletova, V. A.; Kaufhold, T.; Becker, F.; Zeidis, I.; Zimmermann, K.

    2017-06-01

    The paper deals with a tactile sensor inspired by biological hairs of mammals. The working principle is based on the effect of the magnetic force exerted on a paramagnetic body submerged into a ferrofluid volume under the influence of a nonuniform magnetic field. The deflection of the sensor's rod caused by external mechanical stimuli may be unambiguously identified by the distortion of the magnetic field, which occurs due to the motion of the attached body in the ferrofluid. The magnetic force acting on the body is evaluated experimentally and theoretically for the nonuniform magnetic field of a permanent magnet. The controlled oscillations of the rod are realised by applying a nonuniform magnetic field of periodically altering direction.

  6. A magnetic particle micro-trap for large trapping surfaces

    KAUST Repository

    Gooneratne, Chinthaka P.

    2012-01-08

    Manipulation of micron-size magnetic particles of the superparamagnetic type contributes significantly in many applications like controlling the antibody/antigen binding process in immunoassays. Specifically, more target biomolecules can be attached/tagged and analyzed since the three dimensional structure of the magnetic particles increases the surface to volume ratio. Additionally, such biomolecular-tagged magnetic particles can be easily manipulated by an external magnetic field due to their superparamagnetic behavior. Therefore, magnetic particle- based immunoassays are extensively applied in micro-flow cytometry. The design of a square-loop micro-trap as a magnetic particle manipulator as well as numerical and experimental analysis is presented. Experimental results showed that the micro-trap could successfully trap and concentrate magnetic particles from a large to a small area with a high spatial range.

  7. Externalities of energy. Swedish implementation of the ExternE methodology

    International Nuclear Information System (INIS)

    Nilsson, Maans; Gullberg, M.

    1998-01-01

    The growing interest for developing economic instruments for efficient environmental policies has opened up a large area of multi-disciplinary research. ExternE is an example of this research, combining disciplines such as engineering, ecology, immunology and economics expertise to create new knowledge about how environmental pressures from energy production affect our nature and society. The ExternE Project aims to identify and, as far as possible quantify the externalities of energy production in Europe. The Stockholm Environment Institute has carried out a preliminary aggregation: -Coal Fuel Cycle: centred around Vaesteraas Kraftvaermeverk, Vaesteraas. This is the largest co-generation plant in Sweden, with four blocks and a maximum co-generation output of 520 MW electricity and 950 MW heat. The analysis is carried out on boiler B4. -Biomass Fuel Cycle: centred around Haendeloeverket, Norrkoeping. This plant predominately burns forestry residues, but a variety of fuels are combusted. Haendeloeverket has an installed capacity of 100 MW electricity and 375 MW heat, in a total of three boilers and two back-pressure turbines. The analysis is carried out on boiler P13. -Hydro Fuel Cycle: Klippens Kraftstation, Storuman. Built in 1990-1994, it is the youngest hydro power station in Sweden. It has been designed and built with significant efforts to account for and protect environmental values. Installed capacity is 28 MW. The environmental impact assessment from the construction of this plant is carried out, but the evaluation is still not finalized. The preliminary aggregation aimed to test whether ExternE results could be used to make estimates for the entire Swedish electricity production system. Hence, national results as well as results from other partner countries in ExternE has been applied

  8. Passive magnetic bearing system

    Science.gov (United States)

    Post, Richard F.

    2014-09-02

    An axial stabilizer for the rotor of a magnetic bearing provides external control of stiffness through switching in external inductances. External control also allows the stabilizer to become a part of a passive/active magnetic bearing system that requires no external source of power and no position sensor. Stabilizers for displacements transverse to the axis of rotation are provided that require only a single cylindrical Halbach array in its operation, and thus are especially suited for use in high rotation speed applications, such as flywheel energy storage systems. The elimination of the need of an inner cylindrical array solves the difficult mechanical problem of supplying support against centrifugal forces for the magnets of that array. Compensation is provided for the temperature variation of the strength of the magnetic fields of the permanent magnets in the levitating magnet arrays.

  9. Phase diagrams and switching of voltage and magnetic field in dilute magnetic semiconductor nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo, R. [Departamento de Matematica Aplicada y Ciencias de la Computacion, Universidad de Cantabria, 39005 Santander (Spain); Carretero, M.; Bonilla, L.L. [G. Millan Institute, Fluid Dynamics, Nanoscience and Industrial Maths., Universidad Carlos III de Madrid, 28911 Leganes (Spain); Unidad Asociada al Instituto de Ciencia de Materiales, CSIC, 28049 Cantoblanco, Madrid (Spain); Platero, G. [Instituto de Ciencia de Materiales, CSIC, 28049 Cantoblanco, Madrid (Spain)

    2010-04-15

    The response of an n-doped dc voltage biased II-VI multi-quantum well dilute magnetic semiconductor nanostructure having its first well doped with magnetic (Mn) impurities is analyzed by sweeping wide ranges of both the voltage and the Zeeman level splitting induced by an external magnetic field. The level splitting versus voltage phase diagram shows regions of stable self-sustained current oscillations immersed in a region of stable stationary states. Transitions between stationary states and self-sustained current oscillations are systematically analyzed by both voltage and level splitting abrupt switching. Sudden voltage or/and magnetic field changes may switch on current oscillations from an initial stationary state, and reciprocally, current oscillations may disappear after sudden changes of voltage or/and magnetic field changes into the stable stationary states region. The results show how to design such a device to operate as a spin injector and a spin oscillator by tuning the Zeeman splitting (through the applied external magnetic field), the applied voltage and the sample configuration parameters (doping density, barrier and well widths, etc.) to select the desired stationary or oscillatory behavior. Phase diagram of Zeeman level splitting {delta} vs. dimensionless applied voltage {phi} for N = 10 QWs. White region: stable stationary states; black: stable self-sustained current oscillations. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. External effects and social costs of road transport

    NARCIS (Netherlands)

    Verhoef, E.T.

    1994-01-01

    The article contains a welfare economic analysis of road transport's external effects. First, we discuss the definition of external effects. Applying this definition, it is concluded that road transport activities give rise to a wide range of external costs. However, there are no external benefits

  11. 49 CFR 192.461 - External corrosion control: Protective coating.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Protective coating... for Corrosion Control § 192.461 External corrosion control: Protective coating. (a) Each external protective coating, whether conductive or insulating, applied for the purpose of external corrosion control...

  12. Study on magnetic fluid optical fiber devices for optical logic operations by characteristics of superparamagnetic nanoparticles and magnetic fluids

    International Nuclear Information System (INIS)

    Chieh, J. J.; Hong, C. Y.; Yang, S. Y.; Horng, H. E.; Yang, H. C.

    2010-01-01

    We propose two optical fiber-based schemes using two magnetic fluid optical fiber modulators in series or in parallel for optical logic signal processing and operation. Here, each magnetic fluid optical fiber modulator consists of a bare multimode fiber surrounded by magnetic fluid in which the refractive index is adjustable by applying external magnetic fields amplifying the input electrical signal to vary the transmission intensity of the optical fiber-based scheme. The physical mechanisms for the performances of the magnetic fluid optical fiber devices, such as the transmission loss related to Boolean number of the logic operation as well as the dynamic response, are studied by the characteristics of superparamagnetic nanoparticles and magnetic fluids. For example, in the dynamic response composed of the retarding and response sub-procedures except the response times of the actuation coil, the theoretical evaluation of the retarding time variation with cladding magnetic fluids length has good agreement with the experimental results.

  13. Influence of applied tensile stress on the hysteresis curve and magnetic domain structure of grain-oriented Fe–3%Si steel

    Czech Academy of Sciences Publication Activity Database

    Perevertov, Oleksiy; Schäfer, R.

    2014-01-01

    Roč. 47, č. 18 (2014), s. 1-10 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GAP107/11/0391 Grant - others:AVČR(CZ) M100100906 Institutional support: RVO:68378271 Keywords : magnetic domains * magnetization process * magnetoelasticity * hysteresis loops * tension * silicon steel * Kerr microscopy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.721, year: 2014

  14. Theoretical study of in-plane response of magnetic field sensor to magnetic beads in an in-plane homogeneous field

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Hansen, Mikkel Fougt

    2008-01-01

    We present a systematic theoretical study of the average in-plane magnetic field on square and rectangular magnetic field sensors from a single magnetic bead and a monolayer of magnetic beads magnetized by an in-plane externally applied homogeneous magnetic field. General theoretical expressions...... are derived such that the sensor response and its dependence on the sensor size, spacer layer thickness, bead diameter, and bead susceptibility can easily be evaluated. The average magnetic field from a single bead close to the sensor shows a strong dependence on the position of the bead and a change of sign...... when the bead passes the edge of the sensor in the direction of the applied field. Analytical approximations are derived for the average field from a homogeneous monolayer of beads for beads much smaller than the sensor dimension and for a bead size chosen to minimize the position sensitivity...

  15. Magnetoresistance of a two-dimensional electron gas in a random magnetic field

    DEFF Research Database (Denmark)

    Smith, Anders; Taboryski, Rafael Jozef; Hansen, Luise Theil

    1994-01-01

    We report magnetoresistance measurements on a two-dimensional electron gas made from a high-mobility GaAs/AlxGa1-xAs heterostructure, where the externally applied magnetic field was expelled from regions of the semiconductor by means of superconducting lead grains randomly distributed on the surf......We report magnetoresistance measurements on a two-dimensional electron gas made from a high-mobility GaAs/AlxGa1-xAs heterostructure, where the externally applied magnetic field was expelled from regions of the semiconductor by means of superconducting lead grains randomly distributed...

  16. Applying the anisotropy of magnetic susceptibility technique to the study of the tectonic evolution of the West Spitsbergen Fold-and-Thrust Belt

    Directory of Open Access Journals (Sweden)

    Katarzyna Dudzisz

    2016-12-01

    Full Text Available We demonstrate the use of the anisotropy of magnetic susceptibility (AMS method to determine the orientation of the principal tectonic strain directions developed during the formation of the West Spitsbergen Fold-and-Thrust Belt (WSFTB. The AMS measurements and extensive rock-magnetic studies of the Lower Triassic rocks reported here were focused on the recognition of the magnetic fabric, the identification of ferromagnetic minerals and an estimation of the influence of ferro- and paramagnetic minerals on magnetic susceptibility. At most sites, the paramagnetic minerals controlled the magnetic susceptibility, and at only one site the impact of ferromagnetic minerals was higher. The AMS technique documented the presence of different types of magnetic fabrics within the sampled sites. At two sites, a normal (Kmin perpendicular to the bedding magnetic fabric of sedimentary origin was detected. This was associated with a good clustering of the maximum AMS axes imposed by tectonic strain. The Kmax magnetic lineation directions obtained here parallel the general NNW–SSE trend of the WSFTB fold axial traces and thrust fronts. The two other investigated sites possessed mixed and inverted fabrics, the latter of which appear to reflect the presence of iron-bearing carbonates.

  17. Influence of applied compressive stress on the hysteresis curves and magnetic domain structure of grain-oriented transverse Fe–3%Si steel

    Czech Academy of Sciences Publication Activity Database

    Perevertov, Oleksiy; Schäfer, R.

    2012-01-01

    Roč. 45, č. 13 (2012), "135001-1"-"135001-11" ISSN 0022-3727 Grant - others:GA AV ČR(CZ) M100100906 Institutional research plan: CEZ:AV0Z10100520 Keywords : hysteresis curve * magnetic domains * compressive stress * goss steel * effective field Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.528, year: 2012

  18. Investigation of magnetic and transport properties of La0.8Sm0.2O0.5F0.5BiS2 superconductor under external hydrostatic pressure

    Science.gov (United States)

    Kalai Selvan, G.; Arumugam, S.

    2017-10-01

    The dc electrical resistivity and magnetization measurements as a function of temperature 1.8-300 K were formed at external hydrostatic pressures on normal and superconducting state of new polycrystalline BiS2 based layered La0.2Sm0.8BiS2O00.5F0.5 superconductor. In situ, electrical resistivity measurements, At ambient pressure the superconducting transition temperature (T c ) at ~3 K which are enhanced substantially under external pressure to 10.3 K at 1.74 GPa with positive pressure coefficient, dT c /dP= 4.19 K/GPa. Further increasing pressure T c has been decreased upto 6.2 K at 1.96 GPa with negative pressure coefficient dT c /dP= -2.09 K/GPa. From the normal state resistivity exhibits the strong suppression of the semiconducting behavior in La/SmO0.5F0.5BiS2 compounds suggests that the Fermi surface is in the vicinity of some instability. We report here the enhancement of T c from 2.83 to 5.86 K with small increase in pressure upto 0.8 GPa with similar pressure coefficient of dT c /dP= 3.78 K/GPa. However, it should be noted that either chemical substitution or physical pressure on these systems show a dome shaped T c variation which means that the enhancement may not be achieved for higher doping concentration and (or) pressure s beyond an optimum level. In our results, exhibits which higher T c may be achieved lies around 1.74 GPa. Above this pressure the T c may decrease and exhibit a dome shaped behavior similar to other rare –earth systems of BiS2 and Fe-based superconductors. Substantial enhancement of superconductivity under moderate pressure in studied new BiS2 based superconductors call for the attention of condensed matter physics community.

  19. ExternE National Implementation Finland

    International Nuclear Information System (INIS)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P.; Hongisto, M.; Siitonen, S.; Johansson, M.

    1999-01-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  20. ExternE National Implementation Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P. [VTT Energy, Espoo (Finland); Hongisto, M. [Imatran Voima Oy, Vantaa (Finland); Siitonen, S. [Ekono Energy Ltd, Espoo (Finland); Johansson, M. [Finnish Environment Institute, Helsinki (Finland)

    1999-07-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)