WorldWideScience

Sample records for external radiation measurements

  1. External radiation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site.

  2. The direct measurement using an imaging plate for coincidence of radiation centre and laser position in external radiation therapy.

    Science.gov (United States)

    Terunuma, Toshiyuki; Sakae, Takeji; Nohtomi, Akihiro; Tsunashima, Yoshikazu

    2003-02-21

    A new method of quality assurance has been studied to measure coincidence of the radiation centre and a patient-setup laser position on a transverse plane to the beam at the isocentre. This measurement is achieved by using an imaging plate (IP). When radiation is applied to an IP, the energy is stored as trapped electrons. The number of electrons is decreased by local laser exposure. As a result, the radiation field produced by external beam irradiation is recorded as 'positive' information and the position of the patient-setup laser is recorded as 'negative' on an IP. The advantages of this method are the direct measurement, short time and high resolution. These are required for daily and monthly quality checks. We confirmed the advantage of this method by an experiment using a proton beam.

  3. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...... are outlined. The subjects dealt with compromise: the quantity to be measured, the required accuracy of measurement, calibration procedures, and dosemeter design including the main parameters influencing the energy and angular response of the dosemeter, such as detector thickness, filter thickness, dosemeter...

  4. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...... materials and detector/filter geometry. Improvements in the energy and angular response of dosemeters for the measurements of doses from beta and low energy photon radiation can be achieved essentially through two different approaches: either by using thin detectors or multi-element dosemeters...

  5. External Measures of Cognition

    Directory of Open Access Journals (Sweden)

    Osvaldo eCairo

    2011-10-01

    Full Text Available The human brain is undoubtedly the most impressive, complex and intricate organ that has evolved over time. It is also probably the least understood, and for that reason, the one that is currently attracting the most attention. In fact, the number of comparative analyses that focus on the evolution of brain size in Homo sapiens and other species has increased dramatically in recent years. In neuroscience, no other issue has generated so much interest and been the topic of so many heated debates as the difference in brain size between socially defined population groups, both its connotations and implications. For over a century, external measures of cognition have been related to intelligence. However, it is still unclear whether these measures actually correspond to cognitive abilities. In summary, this paper must be reviewed with this premise in mind.

  6. Applied physics of external radiation exposure dosimetry and radiation protection

    CERN Document Server

    Antoni, Rodolphe

    2017-01-01

    This book describes the interaction of living matter with photons, neutrons, charged particles, electrons and ions. The authors are specialists in the field of radiation protection. The book synthesizes many years of experiments with external radiation exposure in the fields of dosimetry and radiation shielding in medical, industrial and research fields. It presents the basic physical concepts including dosimetry and offers a number of tools to be used by students, engineers and technicians to assess the radiological risk and the means to avoid them by calculating the appropriate shields. The theory of radiation interaction in matter is presented together with empirical formulas and abacus. Numerous numerical applications are treated to illustrate the different topics. The state of the art in radiation protection and dosimetry is presented in detail, especially in the field of simulation codes for external exposure to radiation, medical projects and advanced research. Moreover, important data spread in differ...

  7. Direct determination of external radiation dose in human blood

    CERN Document Server

    Tanir, AG; Sahiner, E; Bolukdemir, MH; Koc, K; Meric, N; Keles, SK; Kucuk, O

    2014-01-01

    In this study it was shown that it is possible to determine radiation doses from external beam therapy both directly and retrospectively from a human blood sample. To the best of our knowledge no other studies exist on the direct measurement of doses received by a person from external beam therapy. Optically stimulated luminescence counts from a healthy blood sample exposed to an external radiation source were measured. Blood aliquots were given 0, 1, 2, 3, 4, 5, 10, 15, 20, 25, 50, 100 and 200Gy beta doses and their decay and dose-response curves were plotted. While the luminescence intensities were found to be relatively low for the doses smaller than 10Gy, they were measured considerably higher for doses greater than 10Gy. The dose received by the blood aliquots was determined by interpolating the luminescence counts of 10Gy to the dose-response curve. This study has important ramifications for healthcare, medicine and radiation protection

  8. OCCUPATIONAL EXPOSURE TO EXTERNAL RADIATION IN SWITZERLAND.

    Science.gov (United States)

    Mayer, S; Baechler, S; Damet, J; Elmiger, R; Frei, D; Giannini, S; Leupin, A; Sarott, F; Schuh, R

    2016-09-01

    Individual monitoring for both external and internal exposures is well regulated in Switzerland. The article gives an overview on the occupational exposure to external radiation of workers based on the data collected in the Swiss national dose registry (NDR) in 2013. The NDR records the monthly doses of radiation workers since the introduction of ICRP 60 recommendations and is manifested in the Swiss ordinance since 1994. Annual dose limits for effective dose are typically exceeded once a year in Switzerland, mostly in medicine. The NDR is a useful optimisation tool to identify and characterise areas with the highest exposures. While exceeded dose limits were often related to accidental acute exposure in the past, they are now more related to continuous exposure during normal work, especially in medicine.

  9. Study on external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT.

  10. Building Protection Against External Ionizing Fallout Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, Michael B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Homann, Steven G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-01

    A nuclear explosion has the potential to injure or kill tens to hundreds of thousands of people through exposure to fallout (external gamma) radiation. Existing buildings can protect their occupants (reducing external radiation exposures) by placing material and distance between fallout particles and indoor individuals. This protection is not well captured in current fallout risk assessment models and so the US Department of Defense is implementing the Regional Shelter Analysis methodology to improve the ability of the Hazard Prediction and Assessment Capability (HPAC) model to account for building protection. This report supports the HPAC improvement effort by identifying a set of building attributes (next page) that, when collectively specified, are sufficient to calculate reasonably accurate, i.e., within a factor of 2, fallout shelter quality estimates for many individual buildings. The set of building attributes were determined by first identifying the key physics controlling building protection from fallout radiation and then assessing which building attributes are relevant to the identified physics. This approach was evaluated by developing a screening model (PFscreen) based on the identified physics and comparing the screening model results against the set of existing independent experimental, theoretical, and modeled building protection estimates. In the interests of transparency, we have developed a benchmark dataset containing (a) most of the relevant primary experimental data published by prior generations of fallout protection scientists as well as (b) the screening model results.

  11. Measuring Externalities in Program Evaluation

    NARCIS (Netherlands)

    Janssens, Wendy

    2005-01-01

    Impact evaluations of development programmes usually focus on a comparison of participants with a control group. However, if the programme generates externalities for non-participants such an approach will capture only part of the programme's impact. Based on a unique large-scale quantitative survey

  12. External and internal radiation therapy: Past and future directions

    Directory of Open Access Journals (Sweden)

    Sadeghi Mahdi

    2010-01-01

    Full Text Available Cancer is a leading cause of morbidity and mortality in the modern world. Treatment modalities comprise radiation therapy, surgery, chemotherapy and hormonal therapy. Radiation therapy can be performed by using external or internal radiation therapy. However, each method has its unique properties which undertakes special role in cancer treatment, this question is brought up that: For cancer treatment, whether external radiation therapy is more efficient or internal radiation therapy one? To answer this question, we need to consider principles and structure of individual methods. In this review, principles and application of each method are considered and finally these two methods are compared with each other.

  13. External Beam Radiation in Differentiated Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Salem Billan

    2016-01-01

    Full Text Available The treatment of differentiated thyroid carcinoma (DTC is surgery followed in some cases by adjuvant treatment, mostly with radioactive iodine (RAI. External beam radiotherapy (EBRT is less common and not a well-established treatment modality in DTC. The risk of recurrence depends on three major prognostic factors: extra-thyroid extension, patient’s age, and tumor with reduced iodine uptake. Increased risk for recurrence is a major factor in the decision whether to treat the patient with EBRT. Data about the use of EBRT in DTC are limited to small retrospective studies. Most series have demonstrated an increase in loco-regional control. The risk/benefit from giving EBRT requires careful patient selection. Different scoring systems have been proposed by different investigators and centers. The authors encourage clinicians treating DTC to become familiarized with those scoring systems and to use them in the management of different cases. The irradiated volume should include areas of risk for microscopic disease. Determining those areas in each case can be difficult and requires detailed knowledge of the surgery and pathological results, and also understanding of the disease-spreading pattern. Treatment with EBRT in DTC can be beneficial, and data support the use of EBRT in high-risk patients. Randomized controlled trials are needed for better confirmation of the role of EBRT.

  14. Monte Carlo radiation transport in external beam radiotherapy

    OpenAIRE

    Çeçen, Yiğit

    2013-01-01

    The use of Monte Carlo in radiation transport is an effective way to predict absorbed dose distributions. Monte Carlo modeling has contributed to a better understanding of photon and electron transport by radiotherapy physicists. The aim of this review is to introduce Monte Carlo as a powerful radiation transport tool. In this review, photon and electron transport algorithms for Monte Carlo techniques are investigated and a clinical linear accelerator model is studied for external beam radiot...

  15. External radiation assessment in a wet phosphoric acid production plant

    Energy Technology Data Exchange (ETDEWEB)

    Bolivar, J.P.; Perez-Moreno, J.P. [Dept. Fisica Aplicada, Facultad de Ciencias Experimentales, Universidad de Huelva, 21012 Huelva (Spain); Mas, J.L. [Dept. Fisica Aplicada I, Escuela Universitaria Politecnica, Universidad de Sevilla, 41012 Sevilla (Spain)], E-mail: ppmasb@us.es; Martin, J.E.; San Miguel, E.G. [Dept. Fisica Aplicada, Facultad de Ciencias Experimentales, Universidad de Huelva, 21012 Huelva (Spain); Garcia-Tenorio, R. [Dept. Fisica Aplicada II, Escuela Tecnica Superior de Arquitectura, Universidad de Sevilla, 41012 Sevilla (Spain)

    2009-10-15

    226,228}Ra activity concentrations in the material fluxing during the process (the most important radionuclides from the dosimetric point of view) and the external dose rates. Furthermore, any general dependence of the origin of the rock (i.e., on their radioactive contents) on the external effective dose rate measured has not been observed. These latter findings could be a consequence of three effects: (1) a variable radiation shielding at the different points along the process, (2) a changing geometry of irradiation (from a rock pile up to a thin-layered pulp passing through a solid mass inside pipes and deposits), and (3) the existence of a 'memory effect', or background contamination in the installation equipment due to the presence of radionuclide-enriched scales and sludges in pipes and deposits.

  16. Study of Solid Propellant Combustion under External Radiation

    Directory of Open Access Journals (Sweden)

    V.E. Zarko

    1992-07-01

    Full Text Available The influence of constant and transient radiant flux on the burning rate of solid propellants is considered. The validity of the equivalence principle for the radiant flux and increase in initial temperature and also the problem of possible photochemical effect of thermal radiation are discussed. Experimental data on burning rate response to periodical perturbations of radiant flux for different types of solid propellants are reported. The problem of correlation between burning rate response to perturbations of pressure and external radiation is considered. Formulation of the problem on transient combustion in terms of the Zeldovich- Novozhilov phenomenological approach is described and the results of numerical integration are presented.

  17. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2015-01-01

    This fourth edition reflects recent major developments that have occurred in radiation detector materials, systems, and applications. It continues to provide the most practical and up-to-date introduction to radiation detector technology, proper measurement techniques, and analysis of results for engineers and scientists using radiation sources. New chapters emphasize the expanded use of radiation detection systems in nuclear non-proliferation, homeland security, and nuclear medicine. The book also discusses the correct ways to perform measurements following current health physics procedures.

  18. OPTIMIZATION OF PALLIATIVE EXTERNAL BEAM RADIATION THERAPY FOR BLADDER CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2014-08-01

    Full Text Available Purpose: To improve the efficacy of palliative radiation therapy for patients with bladder cancer (BC.Materials and Methods: In the years 1990−2010, 90 patients with BC were treated with palliative external beam radiation therapy (EBRT using three regimens: conventional fractionation in group 1 (n = 37, hypofractionation in group 2 (n = 22 and accelerated dynamic fractionation in group 3 (n = 31.Results: The immediate efficacy of EBRT was evaluated taking into account rapid relief of local symptoms of disease. In group 1, a clinically significant response (hematuria relief was achieved in 63,0 % cases, in group 2 — in 62,5 %, in group 3 — in 91,7 % cases. The 10-year follow-up showed that in group 1, the median survival was 21,8 ± 3,3 months; in groups 2 and 3, the median survival was 27,0 ± 7,8 and 32,6 ± 9,8 months, respectively. In group 2, an increase in the rate of acute radiation reactions was noted, whereas in group 3, palliative EBRT did not produce higher rates and severity of acute radiation reactions and complications.Conclusion: Accelerated dynamic fractionation was found to shorten treatment times and to improve outcomes and quality of life for incurable patients with BC.

  19. OPTIMIZATION OF PALLIATIVE EXTERNAL BEAM RADIATION THERAPY FOR BLADDER CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2012-01-01

    Full Text Available Purpose: To improve the efficacy of palliative radiation therapy for patients with bladder cancer (BC.Materials and Methods: In the years 1990−2010, 90 patients with BC were treated with palliative external beam radiation therapy (EBRT using three regimens: conventional fractionation in group 1 (n = 37, hypofractionation in group 2 (n = 22 and accelerated dynamic fractionation in group 3 (n = 31.Results: The immediate efficacy of EBRT was evaluated taking into account rapid relief of local symptoms of disease. In group 1, a clinically significant response (hematuria relief was achieved in 63,0 % cases, in group 2 — in 62,5 %, in group 3 — in 91,7 % cases. The 10-year follow-up showed that in group 1, the median survival was 21,8 ± 3,3 months; in groups 2 and 3, the median survival was 27,0 ± 7,8 and 32,6 ± 9,8 months, respectively. In group 2, an increase in the rate of acute radiation reactions was noted, whereas in group 3, palliative EBRT did not produce higher rates and severity of acute radiation reactions and complications.Conclusion: Accelerated dynamic fractionation was found to shorten treatment times and to improve outcomes and quality of life for incurable patients with BC.

  20. The external gamma radiation environment from the Kiwi Phoebus, and Pewee reactors

    Science.gov (United States)

    Malenfant, R. E.

    1972-01-01

    During the past few years, ground tests of high-powered propulsion-prototype reactors have provided several opportunities to observe the external radiation environment. Reactor tests have been conducted in free air and inside of open well shields. Measurements were taken over distances ranging from contact with the pressure vessel out to greater than 5000' both during operation and after shutdown. Some measurements characteristic of each of the systems are presented and compared with results of calculations.

  1. 10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The...

  2. Treatment optimisation using external beam radiation in gynaecological cancers

    Directory of Open Access Journals (Sweden)

    V. Sharma

    2004-03-01

    Full Text Available The majority of patients with gynaecological cancers present with advanced stages in which external beam radiation forms a major component of the treatment. These patients undergo simulation for treatment planning prior to radiation. Currently the lower extent of the disease is evaluated by vaginal examination and marked using a lead wire on the anterior abdominal wall in the pelvic region. A 2 cm margin inferior to this level is used as the lower border of the treatment field. The suggested modified technique includes the placement of an indigenously designed perspex vaginal obturator with graduations at 1 cm distance from its tip. Following vaginal examination the obturator can be inserted into the vagina and fixed at the predefined length using a fixation device. The radio-opaque markers can be seen even in the lateral films. Twentyfive consecutive patients underwent the procedure and the differences between the two methods of marking the lower border were calculated. The external lead wire was inferior to the internal obturator in 19 patients (76% ranging from 0.5 cm to 3 cm (median 1.5 cm, mean 1.37 cm. It was at the same level in 4 patients (16% and 1 cm superior to the internal obturator in 2 (8%. With the modified technique using the internal obturator application for delineating the lower border of vaginal disease or vault, it was possible to decrease the length of field thereby reducing the chances of treatment-related toxicity, especially groin and vulval reactions, as well as avoiding treatment interruptions.

  3. Solar and infrared radiation measurements

    CERN Document Server

    Vignola, Frank; Michalsky, Joseph

    2012-01-01

    The rather specialized field of solar and infrared radiation measurement has become more and more important in the face of growing demands by the renewable energy and climate change research communities for data that are more accurate and have increased temporal and spatial resolution. Updating decades of acquired knowledge in the field, Solar and Infrared Radiation Measurements details the strengths and weaknesses of instruments used to conduct such solar and infrared radiation measurements. Topics covered include: Radiometer design and performance Equipment calibration, installation, operati

  4. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2011-01-01

    This is an update of the standard textbook for the field of radiation measurement. It includes illustrative examples and new problems. The research and applications of nuclear instrumentation have grown substantially since publication of the previous editions. With the miniaturization of equipment, increased speed of electronic components, and more sophisticated software, radiation detection systems are now more productively used in many disciplines, including nuclear nonproliferation, homeland security, and nuclear medicine. Continuing in the tradition of its bestselling predecessors, "Measurement and Detection of Radiation, Third Edition" illustrates the fundamentals of nuclear interactions and radiation detection with a multitude of examples and problems. It offers a clearly written, accessible introduction to nuclear instrumentation concepts. The following are new to the third edition: a new chapter on the latest applications of radiation detection, covering nuclear medicine, dosimetry, health physics, no...

  5. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  6. Measurement of radiative neutralino production

    CERN Document Server

    Bartels, Christoph; Langenfeld, Ulrich; List, Jenny

    2012-01-01

    We perform the first experimental study with full detector simulation for the radiative production of neutralinos at the linear collider, at sqrt{s} = 500 GeV and realistic beam polarizations. We consider all relevant backgrounds, like the Standard Model background from radiative neutrino production. The longitudinal polarized beams enhance the signal and simultaneously reduce the background, such that statistical errors are significantly reduced. We find that the photon spectrum from the signal process can be well isolated. The neutralino mass and the cross section can be measured at a few per-cent level, with the largest systematic uncertainties from the measurement of the beam polarization and the beam energy spectrum.

  7. III. Biological effects of radiation from external and internal sources

    Energy Technology Data Exchange (ETDEWEB)

    Stone, R.S.

    1948-05-24

    This report focuses on the hemotological effects of total body irradiation from external and internal sources observed in patients treated for arthritis with radioactive phosphorus administered intravenously.

  8. External Evaluation Measures for Subspace Clustering

    DEFF Research Database (Denmark)

    Günnemann, Stephan; Färber, Ines; Müller, Emmanuel;

    2011-01-01

    Knowledge discovery in databases requires not only development of novel mining techniques but also fair and comparable quality assessment based on objective evaluation measures. Especially in young research areas where no common measures are available, researchers are unable to provide a fair eva...

  9. Internal and external radiative widths in the combined R-matrix and potential model formalism

    CERN Document Server

    Mukhamedzhanov, A M; Bertulani, C A; Hao, T V Nhan

    2016-01-01

    Using the $R$-matrix approach we calculate the radiative width for a resonance decaying to a bound state through electric dipole, $E1$, transitions. The total radiative width is determined by the interference of the nuclear internal and external radiative width amplitudes. For a given channel radius the external radiative width amplitude is model independent and is determined by the asymptotic normalization coefficient (ANC) of the bound state to which the resonance decays. It also depends on the partial resonance width. To calculate the internal radiative width amplitude we show that a single particle potential model is appropriate. We compare our results with a few experimental data.

  10. Radiation Measurements aboard Spacelab 1

    Science.gov (United States)

    Benton, E. V.; Almasi, J.; Cassou, R.; Frank, A.; Henke, R. P.; Rowe, V.; Parnell, T. A.; Schopper, E.

    1984-07-01

    The radiation environment inside Spacelab 1 was measured by a set of passive radiation detectors distributed throughout the volume inside the module, in the access tunnel, and outside on the pallet. Measurements of the low-LET (linear energy transfer) component obtained from the thermoluminescence detectors ranged from 102 to 190 millirads, yielding an average low-LET dose rate of 11.2 millirads per day inside the module, about twice the low-LET dose rate measured on previous flights of the space shuttle. Because of the higher inclination of the orbit (57 degrees versus 28.5 degrees for previous shuttle flights), substantial fluxes of highly ionizing HZE particles (high charge and energy galactic cosmic rays) were observed, yielding an overall average mission dose-equivalent of about 150 millirems, more than three times higher that measured on previous shuttle missions.

  11. Real-time dosimetry in external beam radiation therapy

    Institute of Scientific and Technical Information of China (English)

    Ramachandran; Prabhakar

    2013-01-01

    With growing complexity in radiotherapy treatment delivery,it has become mandatory to check each and every treatment plan before implementing clinically.This process is currently administered by an independent secondary check of all treatment parameters and as a pre-treatment quality assurance (QA) check for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy treatment plans.Although pre-treatment IMRT QA is aimed to ensure the correct dose is delivered to the patient,it does not necessarily predict the clinically relevant patient dose errors.During radiotherapy,treatment uncertainties can affect tumor control and may increase complications to surrounding normal tissues.To combat this,image guided radiotherapy is employed to help ensure the plan conditions are mimicked on the treatment machine.However,it does not provide information on actual delivered dose to the tumor volume.Knowledge of actual dose delivered during treatment aid in confirming the prescribed dose and also to replan/reassess the treatment in situations where the planned dose is not delivered as expected by the treating physician.Major accidents in radiotherapy would have been averted if real time dosimetry is incorporated as part of the routine radiotherapy procedure.Of late real-time dosimetry is becoming popular with complex treatments in radiotherapy.Realtime dosimetry can be either in the form of point doses or planar doses or projected on to a 3D image dataset to obtain volumetric dose.They either provide entrance dose or exit dose or dose inside the natural cavities of a patient.In external beam radiotherapy,there are four different established platforms whereby the delivered dose information can be obtained:(1)Collimator;(2)Patient;(3)Couch;and(4)Electronic Portal Imaging Device.Current real-time dosimetric techniques available in radiotherapy have their own advantages and disadvantages and a combination of one or more of these methods provide vital information

  12. External Innovation Implementation Determinants and Performance Measurement

    DEFF Research Database (Denmark)

    Coates, Matthew; Bals, Lydia

    2013-01-01

    for innovation implementation based on a case study in the pharmaceutical industry. The results of 25 expert interviews and a survey with 67 respondents led to the resulting framework and a corresponding performance measurement system. The results reveal the importance of supporting systems and show differences...

  13. Measuring space radiation shielding effectiveness

    Science.gov (United States)

    Bahadori, Amir; Semones, Edward; Ewert, Michael; Broyan, James; Walker, Steven

    2017-09-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  14. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... was accomplished, This paper deals with the part of the performance test concerned with exposure to beta radiation. Fifteen dosimetric services participated with whole-body dosemeters intended to measure beta doses (H-p(0.07)) of which 13 used thermoluminescent (TL) detectors and two used photographic films. Eight...... services participated with extremity dosemeters which all used TL detectors. A description is given of the irradiation set-up, the characteristics of the irradiation fields, the calibration quantity applied and the performance criteria used for the evaluation of the results. The paper discusses in detail...

  15. Internal and external stray radiation suppression for LWIR catadioptric telescope using non-sequential ray tracing

    Science.gov (United States)

    Zhu, Yang; Zhang, Xin; Liu, Tao; Wu, Yanxiong; Shi, Guangwei; Wang, Lingjie

    2015-07-01

    A long wave infrared imaging system operated for space exploration of faint target is highly sensitive to stray radiation. We present an integrative suppression process of internal and external stray radiation. A compact and re-imaging LWIR catadioptric telescope is designed as practical example and internal and external stray radiation is analyzed for this telescope. The detector is cryogenically cooled with 100% cold shield efficiency of Lyot stop. A non-sequential ray tracing technique is applied to investigate how the stray radiation propagates inside optical system. The simulation and optimization during initial design stage are proceeded to avoid subversive defect that the stray radiation disturbs the target single. The quantitative analysis of stray radiation irradiance emitted by lenses and structures inside is presented in detail. The optical elements, which operate at room-temperature due to the limitation of weight and size, turn to be the significant stray radiation sources. We propose a method combined infrared material selection and optical form optimization to reduce the internal stray radiation of lens. We design and optimize mechanical structures to achieve a further attenuation of internal stray radiation power. The point source transmittance (PST) is calculated to assess the external radiation which comes from the source out of view field. The ghost of bright target due to residual reflection of optical coatings is simulated. The results show that the performance of stray radiation suppression is dramatically improved by iterative optimization and modification of optomechanical configurations.

  16. Equipment for measuring radiation. Part 3. Technique of measuring radiation

    Energy Technology Data Exchange (ETDEWEB)

    Radwanowski, L.J.

    1979-01-01

    Difficulties are noted in measuring the effects of radiation because of the excessively low energy of the measured fields. In nature there are different magnetic-dynamic and magnetic-hydrodynamic generators which are sources of very low intensity which changes in time. The equipment of measurements is examined in the example of one of the generators, underground water current. The apparatus is described in detail for measuring the intensity of the electromagnetic SHF field. Under the underground water currents a change is observed in the intensity of the electromagnetic field. The possibilities are also examined of direct measurement of ultrasonic elastic fluctuations caused by the underground current, as well as the possibility of recording other physical fields (spontaneous polarization, soil temperature). A study was made of the effect of the underground water current on the occurrence of physical, chemical and biological processes: photochemical reactions, reactions of metal oxidation, Golomb effect (change in the rate of sedimentation of argillaceous particles in water under the influence of a biofield), change in air humidity and soil water content, change in intensity of the magnetic field, Hall effect, change in luminescence of certain organisms or the luminophore released by them. Basic plans are presented of certain measurement and recording devices.

  17. Occupational external exposure to ionising radiation in France (2005-2011).

    Science.gov (United States)

    Feuardent, J; Scanff, P; Crescini, D; Rannou, A

    2013-12-01

    The Institute for Radiological Protection and Nuclear Safety (IRSN) produces the French annual report on occupational exposure to ionising radiation, collecting all national data and aggregating the results according to a unique activity classification expected to be shared by all involved in personal dosimetric monitoring (employers, external dosimetry services and IRSN). Nearly 344,000 monitored workers were counted in France in 2011, with a collective dose of 64.24 man.Sv. The average annual dose (as calculated over the number of measurably exposed workers) differed among the main activity fields: 0.54 mSv in medical and veterinary activities, 1.18 mSv in the nuclear field, 1.60 mSv in non-nuclear industry and 0.47 mSv in research activities. Because of improved knowledge about worker activities, the results for year 2011 are detailed per activity sectors in each field. Lasting limitations prevent from having complete and reliable worker activity information. Solutions are considered to reduce the inaccuracy in the annually published statistics. The evolution of occupational external exposure to ionising radiation from 2005 to 2011 in France is then presented for the main activity fields.

  18. Formation of globular clusters induced by external ultraviolet radiation

    CERN Document Server

    Hasegawa, Kenji; Kitayama, Tetsu

    2009-01-01

    We present a novel scenario for globular cluster (GC) formation, where the ultraviolet (UV) background radiation effectively works so as to produce compact star clusters. Here, we explore the formation of GCs in UV radiation fields. For this purpose, we calculate baryon and dark matter (DM) dynamics in spherical symmetry, incorporating the self-shielding effects by solving the radiative transfer of UV radiation. In addition, we prescribe the star formation in cooled gas components and pursue the dynamics of formed stars. As a result, we find that the evolution of subgalactic objects in UV background radiation are separated into three types, that is, (1) prompt star formation, where less massive clouds ~10^{5-8} M_sun are promptly self-shielded and undergo star formation, (2) delayed star formation, where photoionized massive clouds >10^8 M_sun collapse despite high thermal pressure and are eventually self-shielded to form stars in a delayed fashion, and (3) supersonic infall, where photoionized less massive c...

  19. Individual Dose Monitor of External Radiation Personnel in IMP (1996~2001)

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    For evaluating the individual annual effective dose of eternal radiation personnel in IMP, we monitored individual dose of external radiation personnel every year. The monitoring results are shown in Table 1, from which it is known from 1998 to 2001, we monitored 1099 workers, the mean annual effective dose is 0.13 mSv.

  20. Implication of new CEC recommendations for individual monitoring for external radiation doses to the skin and the extremities

    DEFF Research Database (Denmark)

    Christensen, P.; Julius, H.W.; Marshall, T.O.

    1991-01-01

    to irradiation of the skin and the extremities and focusses on problems connected to exposure to weakly penetrating radiations. Concepts of individual monitoring for external radiation exposures to the skin of the whole body and to the extremities are discussed and guidance is given as regards dose quantities...... and dosemeter calibration procedures. A method of quantifying the overall accuracy of the dose measurements as a result of the various uncertainty components connected with the dosimetry system is suggested and requirements on the accuracy of the dose measurements complying with the ICRP requirements on overall...

  1. Evaluation of arctic broadband surface radiation measurements

    OpenAIRE

    N. Matsui; C. N. Long; Augustine, J.; D. Halliwell; T. Uttal; Longenecker, D.; O. Nievergall; Wendell, J.; Albee, R.

    2011-01-01

    The Arctic is a challenging environment for making in-situ radiation measurements. A standard suite of radiation sensors is typically designed to measure the total, direct and diffuse components of incoming and outgoing broadband shortwave (SW) and broadband thermal infrared, or longwave (LW) radiation. Enhancements can include various sensors for measuring irradiance in various narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are...

  2. Evaluation of Arctic broadband surface radiation measurements

    OpenAIRE

    N. Matsui; C. N. Long; Augustine, J.; D. Halliwell; T. Uttal; Longenecker, D.; Niebergall, O.; Wendell, J.; Albee, R.

    2012-01-01

    The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW) and thermal infrared, or longwave (LW), radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that ...

  3. External radiation dose and cancer mortality among French nuclear workers. Considering potential confounding by internal radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, L.; Laurent, O.; Samson, E.; Caer-Lorho, S.; Laurier, D.; Leuraud, K. [Institute for Radiological Protection and Nuclear Safety, Fontenay aux Roses (France). Ionizing Radiation Epidemiology Lab.; Laroche, P. [AREVA, Paris (France); Le Guen, B. [EDF, Saint Denis (France)

    2016-11-15

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat a l'Energie Atomique), AREVA NC, or EDF (Electricite de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  4. External radiation dose and cancer mortality among French nuclear workers: considering potential confounding by internal radiation exposure.

    Science.gov (United States)

    Fournier, L; Laurent, O; Samson, E; Caër-Lorho, S; Laroche, P; Le Guen, B; Laurier, D; Leuraud, K

    2016-11-01

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat à l'Energie Atomique), AREVA NC, or EDF (Electricité de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  5. Intercomparison of Environmental Nuclear Radiation Measuring

    Institute of Scientific and Technical Information of China (English)

    GAO; Fei; NI; Ning; HOU; Jin-bing; SONG; Ming-zhe

    2015-01-01

    In 2015,Radiation Metrology Division of China Institute of Atomic Energy organized an environmental monitoring of nuclear radiation measuring intercomparison,and 9laboratories attended.The intercomparison included environmental level dosemeters and protection level

  6. A case of the hepatic hilar bile duct cancer with external radiation. Efficacy and severe side effect of external radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Andoh, Hideaki; Yasui, Ouki; Ise, Norihito [Akita Univ. (Japan). School of Medicine

    2003-04-01

    Hepatic hilar bile duct cancer was difficult to cure by surgical treatment and its prognosis was very poor. We present the case of non-curative resection of hepatic hilar bile duct cancer, controlled with external radiation. 72 years-old-female, she complained jaundice and diagnosed hepatic hilar bile duct cancer with abdominal ultrasonography. Hepatic hilar resection was performed but curative resection could not be done, because cancer was diffusely spreaded to the hepatic and duodenal ends of the bile duct. After surgery, external radiation (1.8 Gy/day; total 50.4 Gy) was performed. Three months after operation, sometimes, cholangitis was occurred but we could not detect the intrahepatic bile duct dilatation and improved with antibiotics. After seven months, she was dead for sepsis, liver abscess and biliary cirrhosis. From autopsy findings, severe hepatic hilar fibrosis around the irradiation area, stenosis of the hepatico-jejunostomy and portal vein were existed but could not detect the remnant cancer cells. External radiation was sometimes effective, especially for this case. But we should consider the side effect of fibrosis and preventive treatments such as biliary stenting or early biliary drainage. (author)

  7. External radiation therapy for internal fistulation of malignant obstructive jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Yoshikazu; Miyazaki, Minoru; Yasumasa, Keigo; Higuti, Takuya; Hayashi, Hiroki; Iwahashi, Masahiro; Ishikawa, Shirou; Sumimura, Junichi; Nagai, Isao [Kinan General Hospital, Tanabe, Wakayama (Japan)

    1999-03-01

    Internal fistulation is one of way to improve QOL for patients afflicted by malignant obstructive jaundice. Of 15 patients with obstructive jaundice secondary to malignancy in the past three years, percutaneous transhepatic biliary drainage (PTBD) was performed in all cases, and internal fistulation was achieved in six and not in the other nine. Three of successful cases were irradiated with 10 MV x-ray using parallel opposing fields, with average dose of 29 Gy. There were no complaints of vomiting and nausea, pneumonia, or GI bleeding during radiation therapy. For the irradiated cases, it took 52 days from PTBD to fistulation. Internal fistulated patients had no problem with cholangitis or tube trouble, and all were discharged with good QOL. (author)

  8. Compressibility measurements of gases using externally heated pressure vessels.

    Science.gov (United States)

    Presnall, D. C.

    1971-01-01

    Most of the data collected under conditions of high temperature and pressure have been determined using a thick-walled bomb of carefully measured and fixed volume which is externally heated by an electric furnace or a thermostatically controlled bath. There are numerous variations on the basic method depending on the pressure-temperature range of interest, and the particular gas or gas mixture being studied. The construction and calibration of the apparatus is discussed, giving attention to the pressure vessel, the volume of the bomb, the measurement of pressure, the control and measurement of temperature, and the measurement of the amount and composition of gas in the bomb.

  9. Measurement of background gamma radiation in the northern Marshall Islands.

    Science.gov (United States)

    Bordner, Autumn S; Crosswell, Danielle A; Katz, Ainsley O; Shah, Jill T; Zhang, Catherine R; Nikolic-Hughes, Ivana; Hughes, Emlyn W; Ruderman, Malvin A

    2016-06-21

    We report measurements of background gamma radiation levels on six islands in the northern Marshall Islands (Enewetak, Medren, and Runit onEnewetak Atoll; Bikini and Nam on Bikini Atoll; and Rongelap on Rongelap Atoll). Measurable excess radiation could be expected from the decay of (137)Cs produced by the US nuclear testing program there from 1946 to 1958. These recordings are of relevance to safety of human habitation and resettlement. We find low levels of gamma radiation for the settled island of Enewetak [mean = 7.6 millirem/year (mrem/y) = 0.076 millisievert/year (mSv/y)], larger levels of gamma radiation for the island of Rongelap (mean = 19.8 mrem/y = 0.198 mSv/y), and relatively high gamma radiation on the island of Bikini (mean = 184 mrem/y = 1.84 mSv/y). Distributions of gamma radiation levels are provided, and hot spots are discussed. We provide interpolated maps for four islands (Enewetak, Medren, Bikini, and Rongelap), and make comparisons to control measurements performed on the island of Majuro in the southern Marshall Islands, measurements made in Central Park in New York City, and the standard agreed upon by the United States and the Republic of the Marshall Islands (RMI) governments (100 mrem/y = 1 mSv/y). External gamma radiation levels on Bikini Island significantly exceed this standard (P = <0.01), and external gamma radiation levels on the other islands are below the standard. To determine conclusively whether these islands are safe for habitation, radiation exposure through additional pathways such as food ingestion must be considered.

  10. Natural convection and radiation heat transfer of an externally-finned tube vertically placed in a chamber

    Science.gov (United States)

    Qiu, Yan; Tian, Maocheng; Guo, Zhixiong

    2013-03-01

    A three-dimensional numerical study was made to investigate effects of fin angle, fin surface emissivity, and tube wall temperature on heat transfer enhancement for a longitudinal externally-finned tube placed vertically in a small chamber. The numerical model was first validated through comparison with experimental measurements and the appropriateness of general boundary conditions was examined. The numerical results show that the mean Nusselt number increases with Rayleigh number for all the fin angles investigated. The maximum heat transfer rate per mass occurs when the fin angle is about 60° for fin surface emissivity between 0.7 and 0.8 and 55° when the surface emissivity increases to 0.9. With increasing tube wall temperature, both the natural convection and radiation heat transfer are enhanced, but the fraction of radiation heat transfer decreases in the temperature range studied. Radiation fraction increases with increasing fin surface emissivity. Both convection and radiation heat transfer modes are important.

  11. External urethral sphincter pressure measurement: an accurate method for the diagnosis of detrusor external sphincter dyssynergia?

    Directory of Open Access Journals (Sweden)

    Carlos H Suzuki Bellucci

    Full Text Available BACKGROUND: Combined pelvic floor electromyography (EMG and videocystourethrography (VCUG during urodynamic investigation are the most acceptable and widely agreed methods for diagnosing detrusor external sphincter dyssynergia (DESD. Theoretically, external urethral sphincter pressure (EUSP measurement would provide enough information for the diagnosis of DESD and could simplify the urodynamic investigation replacing combined pelvic floor EMG and VCUG. Thus, we evaluated the diagnostic accuracy of EUSP measurement for DESD. PATIENTS #ENTITYSTARTX00026; METHODS: A consecutive series of 72 patients (36 women, 36 men with neurogenic lower urinary tract dysfunction able to void spontaneously was prospectively evaluated at a single university spinal cord injury center. Diagnosis of DESD using EUSP measurement (index test versus combined pelvic floor EMG and VCUG (reference standard was assessed according to the recommendations of the Standards for Reporting of Diagnostic Accuracy Initiative. RESULTS: Using EUSP measurement (index test and combined pelvic floor EMG and VCUR (reference standard, DESD was diagnosed in 10 (14% and in 41 (57% patients, respectively. More than half of the patients presented discordant diagnosis between the index test and the reference standard. Among 41 patients with DESD diagnosed by combined pelvic floor EMG and VCUR, EUSP measurement identified only 6 patients. EUSP measurement had a sensitivity of 15% (95% CI 5%-25%, specificity of 87% (95% CI 76%-98%, positive predictive value of 60% (95% CI 30%-90%, and negative predictive value of 56% (95% CI 44%-68% for the diagnosis of DESD. CONCLUSIONS: For diagnosis of DESD, EUSP measurement is inaccurate and cannot replace combined pelvic floor EMG and VCUR.

  12. Reduction in stray radiation dose using a body-shielding device during external radiation therapy.

    Science.gov (United States)

    Zhang, Shuxu; Jiang, Shaohui; Zhang, Quanbin; Lin, Shengqu; Wang, Ruihao; Zhou, Xiang; Zhang, Guoqian; Lei, Huaiyu; Yu, Hui

    2017-03-01

    With the purpose of reducing stray radiation dose (SRD) in out-of-field region (OFR) during radiotherapy with 6 MV intensity-modulated radiation therapy (IMRT), a body-shielding device (BSD) was prepared according to the measurements obtained in experimental testing. In experimental testing, optimal shielding conditions, such as 1 mm lead, 2 mm lead, and 1 mm lead plus 10 mm bolus, were investigated along the medial axis of a phantom using thermoluminescent dosimeters (TLDs). The SRDs at distances from field edge were then measured and analyzed for a clinical IMRT treatment plan for nasopharyngeal carcinoma before and after shielding using the BSD. In addition, SRDs in anterior, posterior, left and right directions of phantom were investigated with and without shielding, respectively. Also, the SRD at the bottom of treatment couch was measured. SRD decreased exponentially to a constant value with increasing distance from field edge. The shielding rate was 50%-80%; however, there were no significant differences in SRDs when shielded by 1 mm lead, 2 mm lead, or 1 mm lead plus 10 mm bolus (P>0.05). Importantly, the 10 mm bolus absorbed back-scattering radiation due to the interaction between photons and lead. As a result, 1 mm lead plus 10 mm bolus was selected to prepare the BSD. After shielding with BSD, total SRDs in the OFR decreased to almost 50% of those without shielding when irradiated with IMRT beams. Due to the effects of treatment couch and gantry angle, SRDs at distances were not identical in anterior, posterior, left and right direction of phantom without BSD. As higher dose in anterior and lower dose in posterior, SRDs were substantial similarities after shielding. There was no significant difference in SRDs for left and right directions with or without shielding. Interestingly, SRDs in the four directions were similar after shielding. From these results, the BSD developed in this study may significantly reduce SRD in the OFR during

  13. Plasma response measurements of external magnetic perturbations using electron cyclotron emission and comparisons to 3D ideal MHD equilibrium

    NARCIS (Netherlands)

    Willensdorfer, M.; Denk, S. S.; Strumberger, E.; Suttrop, W.; Vanovac, B.; Brida, D.; Cavedon, M.; Classen, I.; Dunne, M.; Fietz, S.; Fischer, R.; Kirk, A.; Laggner, F. M.; Liu, Y. Q.; Odstrcil, T.; Ryan, D. A.; Viezzer, E.; Zohm, H.; Luhmann, I. C.; ASDEX Upgrade team,; EUROfusion MST1 Team,

    2016-01-01

    The plasma response from an external n = 2 magnetic perturbation field in ASDEX Upgrade has been measured using mainly electron cyclotron emission (ECE) diagnostics and a rigid rotating field. To interpret ECE and ECE-imaging (ECE-I) measurements accurately, forward modeling of the radiation

  14. Birth defects in Norway by levels of external and food-based exposure to radiation from Chernobyl

    Energy Technology Data Exchange (ETDEWEB)

    Lie, R.T.; Irgens, L.M.; Skjaerven, R.; Reitan, J.B.; Strand, P.; Strand, T. (Medical Birth Registry of Norway, University of Bergen (Norway))

    1992-08-15

    In Norway, external doses of radiation resulting from fallout from the Chernobyl nuclear accident were estimated from detailed measurements, including soil deposition patterns. Internal doses were estimated from measurements of radioactive cesium in meat and milk supplies. The doses were calculated as average monthly doses for each of 454 municipalities during 36 consecutive months after the accident in spring 1986. Prospectively collected data on all newborns listed in the Medical Birth Registry of Norway who were conceived in the period May 1983-April 1989 were used to assess possible dose-response relations between estimated external and food-based exposures and congenital malformations and some other conditions. A positive association was observed between total radiation dose (external plus food-based) and hydrocephaly, while a negative association was observed for Down's syndrome. However, an important conclusion of the study was that no associations were found for conditions previously reported to be associated with radiation, i.e., small head circumference, congenital cataracts, anencephaly, spina bifida, and low birth weight. Potential sources of bias, including exposure misclassification and incomplete ascertainment of cases, are discussed.

  15. External dosimetry for ionising radiation. From the national standard to the users in radiotherapy and radiation protection; La dosimetrie externe des rayonnements ionisants de la reference nationale aux utilisateurs en radiotherapie et en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Bordy, J.M

    2009-07-01

    This report presents a review of the external dosimetry of the ionising radiations for the protection of the human being. Looking at this topic, at first we are confronted with its diversity: the protection of the workers and the public against radiations, the medical exposures for radiotherapy, diagnosis and surgery, and the accidental situations. These aspects are often artificially separated so that the global comprehension becomes more difficult. We underline the points of convergence and the bonds which exist between the concepts of dosimetry adopted to deal with its different aspects. It also appeared useful to avoid proposing a dictionary of definitions copied in the reports of the international commissions, and adopting the formalism of the ICRU reports. This is why the definitions, when they are essential, are put in appendix. This text presents the reasons which led to the adoption of the system of quantity used today for the external dosimetry of the ionising radiations. After an introduction dealing with the general principle, the first chapter deals with the 'physical' quantities and the methods used for the determination of the national references. The second chapter, through the protection against radiation of the workers and the public, describes the bonds between the measurable 'operational' quantities and the non measurable 'protections' quantities which allow establishing the radiation protection limits and check that they are respected. The third chapter deals with the difficulties encountered for the measurements in area and personal dosimetry. The fourth chapter deals with the specificities of the medical exposures with the 'practical' quantities, the principle of optimisation and how radiotherapy is implemented. The fifth chapter briefly describes the case of the concerted exposures and of the accident. In conclusion, we analyse the needs and some potential new avenues of work for the metrology of the

  16. Formation of globular clusters induced by external ultraviolet radiation II: Three-dimensional radiation hydrodynamics simulations

    CERN Document Server

    Abe, Makito; Hasegawa, Kenji

    2016-01-01

    We explore the possibility of the formation of globular clusters under ultraviolet (UV) background radiation. One-dimensional spherical symmetric radiation hydrodynamics (RHD) simulations by Hasegawa et al. have demonstrated that the collapse of low-mass (10^6-10^7 solar masses) gas clouds exposed to intense UV radiation can lead to the formation of compact star clusters like globular clusters (GCs) if gas clouds contract with supersonic infall velocities. However, three-dimensional effects, such as the anisotropy of background radiation and the inhomogeneity in gas clouds, have not been studied so far. In this paper, we perform three-dimensional RHD simulations in a semi-cosmological context, and reconsider the formation of compact star clusters in strong UV radiation fields. As a result, we find that although anisotropic radiation fields bring an elongated shadow of neutral gas, almost spherical compact star clusters can be procreated from a "supersonic infall" cloud, since photo-dissociating radiation supp...

  17. External radiation protection audit in National Health Service hospitals. Radiation protecgtion advisors (RPA) of the Nottingham City Hospital NHS Trust and the Oxford Radcliffe Hospital NHS Trust.

    Science.gov (United States)

    Rogers, A T; Crawley, M T; Dixon-Brown, A; Dudley, N J; Nicholas, D; Pearson, D; Przeslak, A; Weatherburn, H

    1996-11-01

    Radiation protection advisers are accustomed to carrying out internal audit in organizations for which they provide services but, traditionally, external audit has not been a part of the radiation protection adviser function. To provide an external audit function, two teams of radiation protection advisers undertook external radiation protection audits of their respective organizations, including the radiation protection adviser function itself. These audits were more representative of audits or inspections carried out by government agencies, for example the Health and Safety Executive and the former Inspectorate of Pollution, now the Environment Agency. Subsequently, reports, including recommendations for remedial action, were prepared for each management by the external auditors. The process of setting up and carrying out the external audits is described. Guidelines are suggested for those seeking to carry out an external audit.

  18. External and internal exposure to natural radiations inside ancient Egyptian tombs in Saqqara

    Energy Technology Data Exchange (ETDEWEB)

    Abo-Elmagd, M. [National Institute for Standard, Radiation Measurements Department, P.O. Box 136 Giza code no. 12211 (Egypt)]. E-mail: abo_elmgd@hotmail.com; Metwally, S.M. [Faculty of Science, Department of Physics, Ain Shams University, P.O. Box 11566, Cairo (Egypt); Elmongy, S.A. [Atomic Energy Authority, Nuclear Safety, Cairo (Egypt); Salama, E. [Faculty of Science, Department of Physics, Ain Shams University, P.O. Box 11566, Cairo (Egypt); El-Fiki, S.A. [Faculty of Science, Department of Physics, Ain Shams University, P.O. Box 11566, Cairo (Egypt)

    2006-02-15

    Some ancient Egyptian tombs in Saqqara are closed for visit to undergo fixation processes. The workers inside these tombs exposed to natural radiations from natural Gamma emitters (external exposure) and inhale unknown radon doses (internal exposure) for long periods. The external exposure in all studied tombs is lower than the maximum recommended action level. The internal exposure in terms of annual effective dose in the south tomb is equal to 28.83mSv/year which highly exceed the recommended level (3-10mSv/year). In this tomb, the external exposure is equal to 21.43{mu}Sv/year. This reflects the hazards of radon over the other natural radiations in the closed area. Among the workers inside the studied tombs, the expected morality is equal to 0.0033%, 0.0199% and 0.0724% for the south entrance of Zoser pyramid, the Serapeum tomb, and the south tomb respectively. ctively.

  19. Pelvic complications after definitive treatment of prostate cancer by interstitial or external beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schellhammer, P.F.; El-Mahdi, A.M.

    1983-05-01

    Radiation complications, after definitive treatment of localized prostatic carcinoma by either external beam or interstitial implantation with Iodine-125 seeds, are reviewed. Late serious complications to immediately adjacent structures of the anterior rectal wall, prostatic urethra, bladder neck, and external sphincter occurred with similar frequency in both treatment groups. However, late serious complications of the remotely adjacent structures of the bladder, urethra, distal ureters, and circumferential rectal wall occurred more frequently in the external beam treatment series, a reflection of the fact that larger tissue volumes were irradiated. Rectal ulceration, while occurring in both treatment groups, was amenable to surgical correction or underwent spontaneous healing only in the 125I group. At this point in our experience, morbidity from late radiation complications has been less among those patients having interstitial implantation for definitive treatment of localized prostatic carcinoma.

  20. Probe And Enhancement Of SBS Based Phonons In Infrared Fibers Using Waveguide Coupled External Radiation

    Science.gov (United States)

    Yu, Chung; Chong, Yat C.; Fong, Chee K.

    1989-06-01

    Interaction of GHz and MHz radiation with CO2 laser propagation in a silver halide fiber using sBs based phonon coupling is furthet investigated. The external signal serves to both probe and enhance laser generated sBs phonons in the fiber. Efficient coupling of microwave radiation into the fiber is accomplished by placing the fiber in a hollow metallic waveguide, designed and constructed to transmit the dominant mode in the 0.9-2.0 GHz band. MHz radiation is conveniently coupled into the fiber using the guided microwave radiation as carrier. Phonon emissions from the fiber under CO2 laser pumping are first established on a spectrum analyzer; low frequency generators ale then tuned to match these frequencies and their maximum interaction recorded. Such interactions are systematically studied by monitoring the amplitude and waveform of the reflected and transmitted laser pulse at various power levels and frequencies of the externally coupled radiation. A plot of reflected laser power versus incident laser power reveals a distinct sBs generated phonon threshold. Variouslaunch directions of the GHz and MHz radiation with respect to the direction of laser propagation are realized to verify theory governing sBs interactions. The MHz radiation and its associated phonons in the fiber are convenient tools for probing sBs related phenomenon in infrared fibers.

  1. Teeth characterization using external PIGE-PIXE measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rizzutto, M.A.; Added, N.; Liguori Neto, R.; Machado, L.P.; Tabacniks, M.H.; Acquadro, J.C. [Universidade de Sao Paulo, SP (Brazil). Inst. de Fisica; Vilela, M.M. [Universidade de Sao Paulo, SP (Brazil). Inst. de Eletrotecnica; Oliveira, T.R.C.F.; Markarian, R.A.; Mori, M. [Universidade de Sao Paulo, SP (Brazil). Faculdade de Odontologia

    2001-07-01

    An external PIGE-PIXE setup was installed in the Open Nuclear Physics Laboratory (LAFN) at the 8 MV tandem Pelletron accelerator, aiming to use a proton beam to probe samples. Specific characteristics of the accelerator allowed to set the beam energy high enough as to get an acceptable gamma ray yield but not too high as to prevent from measuring X-rays. The energetic proton beam also allowed to use a thick aluminium exit window (0.5 mm) instead of the usual thin plastic windows, since there is no need for a true monoenergetic beam or even keeping beam straggling low. A crossed laser beam was used for positioning the samples on a XYZ table. The external PIXE-PIGE system is being used to analyse archaeological, biological, thin films and thick metallic samples. Results for the characterization of cattle, swine and human teeth show significant differences in the composition of the trace elements (author)

  2. Measuring External Sources of Background (R&D) at Homestake

    Science.gov (United States)

    Mei, Dongming; Chan, Yuen-Dat; Elliott, Steve; Gray, Frederick; Keller, Christina; Sun, Yongchen

    2008-04-01

    Measuring external sources of radioactivity at the DUSEL site is the key to success in low-energy neutrino and dark matter (WIMP searches) experiments. Natural radioactivity can be measured using germanium and NaI detectors. Muon-induced neutrons and (a,n) neutrons will be measured utilizing liquid scintillators and germanium detectors through the 72Ge(n,nxe) reaction. External sources of background, particularly fast neutrons and cosmogenic radioactivity from muon-induced processes, are background matter that must be eliminated for underground experiments in pursuit of double beta decay, WIMPs, and oscillations of low-energy neutrinos. However, muon-induced neutron production rates with heavy elements, such as lead and copper, are not well understood. The discrepancy between the measurements and FLUKA simulations is as large as about a factor of 3. This discrepancy needs be understood for the muon- induced fast neutron production rate in lead and copper, which are the most popular materials for shielding underground experiments. We propose an experiment at 300-ft level to measure the muon-induced fast neutron production rate in different targets.

  3. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.;

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, whi...

  4. Measurement of the Radiation Dose Rates of Patients Receiving Treatment with I-131 Using Telescopic Radiation Survey Meter

    Directory of Open Access Journals (Sweden)

    Yehia Lahfi

    2016-03-01

    Full Text Available Introduction In order to discharge the patients receiving treatment with large radiation doses of 131I for thyroid cancer, it is necessary to measure and evaluate the external dose rates of these patients. The aim of the study was to assess a new method of external dose rate measurement, and to analyze the obtained results as a function of time. Materials and Methods In this study, a telescopic radiation survey meter was utilized to measure the external dose rates of a sample population of 192 patients receiving treatment with high-dose 131I at one, 24, and 48 hours after dose administration. Results The proposed technique could reduce the occupational radiation exposure of the physicist by a factor of 1/16. Moreover, the external dose rates of both genders rapidly decreased with time according to bi-exponential equations, which could be attributed to the additional factors associated with iodine excretion, as well as the physiology of the body in terms of 131I uptake. Conclusion According to the results of this study, telescopic radiation survey meter could be used to measure the external dose rates of patients receiving treatment with 131I. Furthermore, the average difference in the radiation exposure between female and male patients was calculated to be less than 17%.

  5. Diffuse solar radiation: measurement reliability

    Energy Technology Data Exchange (ETDEWEB)

    Butera, F.M.; Farruggia, S.; Festa, R.; Ratto, C.

    Numerous empirical relationships, found in literature, allow - where only the average monthly or daily value of global radiation on a horizontal surface is known - the determination of the components of both diffuse and direct radiations. These relationships result from the elaboration of data recorded mostly at weather stations located in North America. With the use of hourly data of global and diffuse solar radiation, recorded in Genova, Italy, during a period of six years, it is shown that the above mentioned relationships give values which systematically differ from experimental ones, even if some offer better results than others. Furthermore, the extent of the difference and the similar results obtained from other researchers indicate the possibility of specific weather conditions in the Mediterranean area.

  6. Measurement of advanced electromagnetic radiation

    OpenAIRE

    Bajlo, Darko

    2017-01-01

    For the purpose of detecting advanced electromagnetic radiation predicted by Wheeler-Feynman absorber theory for the case of incomplete absorption of retarded electromagnetic radiation, pulses in duration of 6 ns to 24 ns, wavelength from 91 cm to 200 cm where supplied to three different transmitting antennas. Detection was done with a λ/20 monopole antenna in the advanced time window at a time 2r/c before the arrival of the center of the retarded pulse. At distances ranging from 430 cm to 18...

  7. Effects of External Radiation Fields on Line Emission—Application to Star-forming Regions

    Science.gov (United States)

    Chatzikos, Marios; Ferland, G. J.; Williams, R. J. R.; Porter, Ryan; van Hoof, P. A. M.

    2013-12-01

    A variety of astronomical environments contain clouds irradiated by a combination of isotropic and beamed radiation fields. For example, molecular clouds may be irradiated by the isotropic cosmic microwave background, as well as by a nearby active galactic nucleus. These radiation fields excite atoms and molecules and produce emission in different ways. We revisit the escape probability theorem and derive a novel expression that accounts for the presence of external radiation fields. We show that when the field is isotropic the escape probability is reduced relative to that in the absence of external radiation. This is in agreement with previous results obtained under ad hoc assumptions or with the two-level system, but can be applied to complex many-level models of atoms or molecules. This treatment is in the development version of the spectral synthesis code CLOUDY. We examine the spectrum of a Spitzer cloud embedded in the local interstellar radiation field and show that about 60% of its emission lines are sensitive to background subtraction. We argue that this geometric approach could provide an additional tool toward understanding the complex radiation fields of starburst galaxies.

  8. Formation of globular clusters induced by external ultraviolet radiation - II. Three-dimensional radiation hydrodynamics simulations

    Science.gov (United States)

    Abe, Makito; Umemura, Masayuki; Hasegawa, Kenji

    2016-12-01

    We explore the possibility of the formation of globular clusters (GCs) under ultraviolet (UV) background radiation. One-dimensional spherical symmetric radiation hydrodynamics (RHD) simulations by Hasegawa et al. have demonstrated that the collapse of low-mass (106-7 M⊙) gas clouds exposed to intense UV radiation can lead to the formation of compact star clusters like GCs if gas clouds contract with supersonic infall velocities. However, three-dimensional effects, such as the anisotropy of background radiation and the inhomogeneity in gas clouds, have not been studied so far. In this paper, we perform three-dimensional RHD simulations in a semicosmological context, and reconsider the formation of compact star clusters in strong UV radiation fields. As a result, we find that although anisotropic radiation fields bring an elongated shadow of neutral gas, almost spherical compact star clusters can be procreated from a `supersonic infall' cloud, since photodissociating radiation suppresses the formation of hydrogen molecules in the shadowed regions and the regions are compressed by UV heated ambient gas. The properties of resultant star clusters match those of GCs. On the other hand, in weak UV radiation fields, dark-matter-dominated star clusters with low stellar density form due to the self-shielding effect as well as the positive feedback by ionizing photons. Thus, we conclude that the `supersonic infall' under a strong UV background is a potential mechanism to form GCs.

  9. Radiation optic neuropathy after external beam radiation therapy for acromegaly : report of two cases

    NARCIS (Netherlands)

    van den Bergh, ACM; Hoving, MA; Links, TP; Dullaart, RPF; Ranchor, AV; ter Weeme, CA; Canrinus, AA; Szabo, BG; Pott, JWR

    2003-01-01

    For diagnosing radiation optic neuropathy (RON) ophthalmological and imaging data were evaluated from 63 acromegalic patients, irradiated between 1967 and 1998. Two patients developed RON: one patient in one optic nerve 10 years and another patient in both optic nerves 5 months after radiation thera

  10. A case report of a crisis caused by external radiation in the malignant pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Akiyo; Tena, Shinichi; Nomura, Kaoru; Demura, Hiroshi [Tokyo Women`s Medical Coll. (Japan)

    1996-08-01

    A case of a severe complication not described hitherto was reported, which was caused by external radiation to bone metastasis of malignant pheochromocytoma to resolve pain. The patient, a female of 59 y, with multiple bone metastasis gave MRI findings of tumor lesion and osteolysis at thoracic vertebra. Internal radiation was thought to be ineffective since the uptake of {sup 131}I-MIBG was insufficient in the tumor. Alpha-methyl tyrosine, phentolamine and propranolol were treated. After external irradiation of total dose of 20 Gy/week to thoracic vertebra was done at a single dose of 4 Gy to resolve pain, a crisis of hypertension (200/110 mmHg) was caused accompanying with tachycardia (160/min), perspiration, cold feeling of limb, dehydration and increase of serum LDH, ALP and K. The symptom was improved by the dose increase of alpha-methyltyrosine and other above drugs. This case indicates that even a small dose of external radiation can cause a crisis described above in pheochromocytoma and alpha- and beta-blockers together with inhibitor of catecholamine synthesis should be given before radiation. (K.H.)

  11. Improving efficiency and safety in external beam radiation therapy treatment delivery using a Kaizen approach.

    Science.gov (United States)

    Kapur, Ajay; Adair, Nilda; O'Brien, Mildred; Naparstek, Nikoleta; Cangelosi, Thomas; Zuvic, Petrina; Joseph, Sherin; Meier, Jason; Bloom, Beatrice; Potters, Louis

    2017-06-29

    Modern external beam radiation therapy treatment delivery processes potentially increase the number of tasks to be performed by therapists and thus opportunities for errors, yet the need to treat a large number of patients daily requires a balanced allocation of time per treatment slot. The goal of this work was to streamline the underlying workflow in such time-interval constrained processes to enhance both execution efficiency and active safety surveillance using a Kaizen approach. A Kaizen project was initiated by mapping the workflow within each treatment slot for 3 Varian TrueBeam linear accelerators. More than 90 steps were identified, and average execution times for each were measured. The time-consuming steps were stratified into a 2 × 2 matrix arranged by potential workflow improvement versus the level of corrective effort required. A work plan was created to launch initiatives with high potential for workflow improvement but modest effort to implement. Time spent on safety surveillance and average durations of treatment slots were used to assess corresponding workflow improvements. Three initiatives were implemented to mitigate unnecessary therapist motion, overprocessing of data, and wait time for data transfer defects, respectively. A fourth initiative was implemented to make the division of labor by treating therapists as well as peer review more explicit. The average duration of treatment slots reduced by 6.7% in the 9 months following implementation of the initiatives (P = .001). A reduction of 21% in duration of treatment slots was observed on 1 of the machines (P Kaizen approach has the potential to improve operational efficiency and safety with quick turnaround in radiation therapy practice by addressing non-value-adding steps characteristic of individual department workflows. Higher effort opportunities are identified to guide continual downstream quality improvements. Copyright © 2017. Published by Elsevier Inc.

  12. Effects of External Radiation Fields on Line Emission - Application to Star-forming Regions

    CERN Document Server

    Chatzikos, Marios; Williams, Robin; van Hoof, Peter; Porter, Ryan

    2013-01-01

    A variety of astronomical environments contain clouds irradiated by a combination of isotropic and beamed radiation fields. For example, molecular clouds may be irradiated by the isotropic cosmic microwave background (CMB), as well as by a nearby active galactic nucleus (AGN). These radiation fields excite atoms and molecules and produce emission in different ways. We revisit the escape probability theorem and derive a novel expression that accounts for the presence of external radiation fields. We show that when the field is isotropic the escape probability is reduced relative to that in the absence of external radiation. This is in agreement with previous results obtained under ad hoc assumptions or with the two-level system, but can be applied to complex many-level models of atoms or molecules. This treatment is in the development version of the spectral synthesis code Cloudy. We examine the spectrum of a Spitzer cloud embedded in the local interstellar radiation field, and show that about 60 percent of it...

  13. Modeling of Intrinsic Josephson Junctions in High Temperature Superconductors under External Radiation in the Breakpoint Region

    Directory of Open Access Journals (Sweden)

    Shukrinov Yu. M.

    2016-01-01

    Full Text Available The current-voltage (IV characteristics of the intrinsic Josephson junctions in high temperature superconductors under external electromagnetic radiation are calculated numerically in the parametric resonance region. We discuss a numerical method for calculation of the Shapiro step width on the amplitude of radiation. In order to accelerate computations we used parallelization by task parameter via Simple Linux Utility for Resource Management (SLURM arrays and tested it in the case of a single junction. An analysis of the junction transitions between rotating and oscillating states in the branching region of IV-characteristics is presented.

  14. Modeling of Intrinsic Josephson Junctions in High Temperature Superconductors under External Radiation in the Breakpoint Region

    Science.gov (United States)

    Shukrinov, Yu. M.; Rahmonov, I. R.; Plecenik, A.; Streltsova, O. I.; Zuev, M. I.; Ososkov, G. A.

    2016-02-01

    The current-voltage (IV) characteristics of the intrinsic Josephson junctions in high temperature superconductors under external electromagnetic radiation are calculated numerically in the parametric resonance region. We discuss a numerical method for calculation of the Shapiro step width on the amplitude of radiation. In order to accelerate computations we used parallelization by task parameter via Simple Linux Utility for Resource Management (SLURM) arrays and tested it in the case of a single junction. An analysis of the junction transitions between rotating and oscillating states in the branching region of IV-characteristics is presented.

  15. Vision System Measures Motions of Robot and External Objects

    Science.gov (United States)

    Talukder, Ashit; Matthies, Larry

    2008-01-01

    A prototype of an advanced robotic vision system both (1) measures its own motion with respect to a stationary background and (2) detects other moving objects and estimates their motions, all by use of visual cues. Like some prior robotic and other optoelectronic vision systems, this system is based partly on concepts of optical flow and visual odometry. Whereas prior optoelectronic visual-odometry systems have been limited to frame rates of no more than 1 Hz, a visual-odometry subsystem that is part of this system operates at a frame rate of 60 to 200 Hz, given optical-flow estimates. The overall system operates at an effective frame rate of 12 Hz. Moreover, unlike prior machine-vision systems for detecting motions of external objects, this system need not remain stationary: it can detect such motions while it is moving (even vibrating). The system includes a stereoscopic pair of cameras mounted on a moving robot. The outputs of the cameras are digitized, then processed to extract positions and velocities. The initial image-data-processing functions of this system are the same as those of some prior systems: Stereoscopy is used to compute three-dimensional (3D) positions for all pixels in the camera images. For each pixel of each image, optical flow between successive image frames is used to compute the two-dimensional (2D) apparent relative translational motion of the point transverse to the line of sight of the camera. The challenge in designing this system was to provide for utilization of the 3D information from stereoscopy in conjunction with the 2D information from optical flow to distinguish between motion of the camera pair and motions of external objects, compute the motion of the camera pair in all six degrees of translational and rotational freedom, and robustly estimate the motions of external objects, all in real time. To meet this challenge, the system is designed to perform the following image-data-processing functions: The visual-odometry subsystem

  16. Treatment of Head and Neck Paragangliomas With External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, Charles, E-mail: c.dupin@bordeaux.unicancer.fr [Department of Radiotherapy, Comprehensive Cancer Center, Institut Bergonié, Bordeaux (France); Lang, Philippe [Department of Radiotherapy, Pitié Salpétrière, Paris (France); Dessard-Diana, Bernadette [Department of Radiotherapy, Hopital Européen Georges Pompidou, Paris (France); Simon, Jean-Marc; Cuenca, Xavier; Mazeron, Jean-Jacques; Feuvret, Loïc [Department of Radiotherapy, Pitié Salpétrière, Paris (France)

    2014-06-01

    Purpose: To retrospectively assess the outcomes of radiation therapy in patients with head and neck paragangliomas. Methods and Materials: From 1990 to 2009, 66 patients with 81 head and neck paragangliomas were treated by conventional external beam radiation therapy in 25 fractions at a median dose of 45 Gy (range, 41.4-68 Gy). One case was malignant. The median gross target volume and planning target volume were 30 cm{sup 3} (range, 0.9-243 cm{sup 3}) and 116 cm{sup 3} (range, 24-731 cm{sup 3}), respectively. Median age was 57.4 years (range, 15-84 years). Eleven patients had multicentric lesions, and 8 had family histories of paraganglioma. Paragangliomas were located in the temporal bone, the carotid body, and the glomus vagal in 51, 18, and 10 patients, respectively. Forty-six patients had exclusive radiation therapy, and 20 had salvage radiation therapy. The median follow-up was 4.1 years (range, 0.1-21.2 years). Results: One patient had a recurrence of temporal bone paraganglioma 8 years after treatment. The actuarial local control rates were 100% at 5 years and 98.7% at 10 years. Patients with multifocal tumors and family histories were significantly younger (42 years vs 58 years [P=.002] and 37 years vs 58 years [P=.0003], respectively). The association between family predisposition and multifocality was significant (P<.001). Two patients had cause-specific death within the 6 months after irradiation. During radiation therapy, 9 patients required hospitalization for weight loss, nausea, mucositis, or ophthalmic zoster. Two late vascular complications occurred (middle cerebral artery and carotid stenosis), and 2 late radiation-related meningiomas appeared 15 and 18 years after treatment. Conclusion: Conventional external beam radiation therapy is an effective and safe treatment option that achieves excellent local control; it should be considered as a first-line treatment of choice for head and neck paragangliomas.

  17. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Eftekhari

    2015-01-01

    Full Text Available Objective(s: Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. Results: A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed and 36 patients with right-sided cancer (controls] were enrolled. Dose-volume histogram (DVH [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46. In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03 and anterolateral (17.1% versus 2.8%, P=0.049 walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS of>3 was observed in twelve cases (34.3%, while in five of the controls (13.9%,(Odds ratio=1.3. There was no significant difference between the groups regarding left ventricular ejection fraction. Conclusion: The risk of radiation induced myocardial

  18. Analysis of the mortality among Cogema workers monitored for external radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Flamant, C.; Hitz, M.; Samson, E.; Rogel, A.; Telle-Lamberton, M.; Tirmarche, M. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Fontenay-aux-Roses (France); Caer, S.; Quesne, B. [Cogema, Coordination Medicale, 78 - Velizy-Villacoublay (France)

    2006-07-01

    The present study follows 9287 Cogema workers exposed to low level of ionizing radiation from the beginning of employment to the end of 1994. This paper presents analyses of the mortality of Cogema workers monitored for external radiation exposure and the relation between their mortality and their cumulative external radiation dose. Workers were followed up for an average of 13 years. The percentage of subjects lost to follow up was less than 1%. during the follow-up period, 441 deaths occurred. The mean cumulative dose among the whole cohort was 19.4 mSv. As expected, the mortality of the cohort was lower than that of the French national population. The healthy worker effect is often observed in other nuclear workers studies. Part of the healthy worker effect is explained by a proportion of unemployed persons in general population, with a higher mortality rate. All causes S.M.R. increased with calendar period and duration of employment. this increase was not significant for all cancers S.M.R. by duration of employment. This could illustrate the decrease of the initial selection at employment with time. A significant increase in risk was observed for all cancers excluding leukemia mortality with increase of radiation dose in the 15-country study. Significant excess of leukemia by cumulative radiation exposure was observed in the 3-country study and was borderline significant in the 15-country study and in the UK National register for radiation workers study. A positive trend, not statistically significant, by level of external doses was observed in our study for all cancers and leukemia excluding chronic lymphatic leukemia mortality, but the analyses lack of statistical power. A significant trend was observed only for non-Hodgkin lymphoma death, but considering the large number of statistic tests computed, this result must be carefully interpreted. A borderline significant trend was observed for lung cancer death, a significant increase risk of lung cancer death

  19. Solar-Radiation Measuring Equipment and Glossary

    Science.gov (United States)

    Carter, E. A.; Patel, A. M.; Greenbaum, S. A.

    1982-01-01

    1976 listing of commercially available solar-radiation measuring equipment is presented in 50-page report. Sensor type, response time, cost data, and comments concerning specifications and intended usage are listed for 145 instruments from 38 manufactures.

  20. Southern Great Plains Atmospheric Radiation Measurement Site

    Data.gov (United States)

    Federal Laboratory Consortium — The Southern Great Plains Atmospheric Radiation Measurement Site (SGP-ARM) is the oldest and largest of DOE's Arm sites. It was established in 1992. It consists of...

  1. Phantoms for Radiation Measurements of Mobile Phones

    DEFF Research Database (Denmark)

    Pedersen, Gert Frølund

    2001-01-01

    Measurements of radiation efficiency for a handheld phone equipped with a patch and a helical antenna operated near the human user have been performed. Both measurements include a simple head plus hand phantom and live persons are considered. The position of the hand on the phone is found...... to be the main reason for the large variation in radiation efficiency among persons. The tilt angle of the phone and the distance between the head and phone only play a minor role...

  2. A simple external resistance heating diamond anvil cell and its application for synchrotron radiation x-ray diffraction.

    Science.gov (United States)

    Fan, Dawei; Zhou, Wenge; Wei, Shuyi; Liu, Yonggang; Ma, Maining; Xie, Hongsen

    2010-05-01

    A simple external heating assemblage allowing diamond anvil cell experiments at pressures up to 34 GPa and temperatures up to 653 K was constructed. This cell can be connected to the synchrotron radiation conveniently. The design and construction of this cell are fully described, as well as its applications for x-ray diffraction. Heating is carried out by using an external-heating system, which is made of NiCr resistance wire, and the temperature was measured by a NiCr-NiSi or PtRh-Pt thermocouple. We showed the performance of the new system by introducing the phase transition study of cinnabar (alpha-HgS) and thermal equation of state study of almandine at high pressure and temperature with this cell.

  3. Influence of external magnetic and laser radiation fields on Feshbach resonances in collision of atoms

    CERN Document Server

    Gazazyan, E A; Chaltykyan, V O

    2012-01-01

    We study collision of two atoms with formation of Feshbach resonance at combined interaction with the external magnetic field and laser radiation. In cases of one- and two-photon resonances of laser radiation with two discrete vibrational molecular levels, we show that Feshbach resonances appear at interaction of external magnetic field with dressed states formed via Autler-Townes effect. In addition, in case of one-photon resonance the lower vibrational molecular state is coupled by laser radiation with the continuum of the elastic channel and forms laser-induced Feshbach resonance via both Autler-Townes effect and LICS mechanism. We study the combined process of formation of Feshbach resonances; this enables the control of Feshbach resonance by varying the magnetic field and intensity and frequency of laser radiation. We obtain the cross-sections of elastic and inelastic scattering and show that quenching of resonance occurs at the energy equal to that of the systems ground state. Dependence of the cross-se...

  4. The Evolution of External Beam Radiation Therapy (EBRT) from a Technological Perspective.

    Science.gov (United States)

    Detorie, Nicholas

    2008-03-01

    Since the discovery of x-rays by Roentgen in 1895 ionizing radiations have been used as a treatment for cancer. Such treatments have been based on either implantation of radioactive materials at the site of disease or by aiming external radiation beams at the diseased site. This later method is referred to as teletherapy because the beams originate from a location outside of the body distant from the disease site itself. A brief review of the basic radiation biology will be given to illustrate the rationale for therapeutic use of ionizing radiations and the effects of beam energy and beam type- particulate or photon. The remainder of the presentation will focus on the technological teletherapy developments supported by the required physical properties of the beams and their associated characteristics that make them suitable for patient treatments. Chronological highlights will include the following sources or devices: superficial x-rays, orthovaltage x-rays, megavoltage x-rays and Cobalt 60 photons, electron beams, neutron beams, negative pi mesons, protons, and heavy ions. The presentation will illustrate how the physical beam properties have been incorporated into modern radiation treatment devices, many of which are equipped with radiation imaging capability. Such devices include: linacs equipped with multileaf collimators for beam shaping and intensity modulation, the Gamma Knife for precise and accurate irradiation of brain tumors or arterial-venous malformations (AVM), the robotic arm based Cyber Knife, and the Helical Tomotherapy unit.

  5. Evaluation of arctic broadband surface radiation measurements

    Directory of Open Access Journals (Sweden)

    N. Matsui

    2011-08-01

    Full Text Available The Arctic is a challenging environment for making in-situ radiation measurements. A standard suite of radiation sensors is typically designed to measure the total, direct and diffuse components of incoming and outgoing broadband shortwave (SW and broadband thermal infrared, or longwave (LW radiation. Enhancements can include various sensors for measuring irradiance in various narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers that rotate sensors and shading devices that track the sun. High quality measurements require striking a balance between locating sensors in a pristine undisturbed location free of artificial blockage (such as buildings and towers and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data include solar tracker malfunctions, rime/frost/snow deposition on the instruments and operational problems due to limited operator access in extreme weather conditions. In this study, a comparison is made between the global and component sum (direct [vertical component] + diffuse shortwave measurements. The difference between these two quantities (that theoretically should be zero is used to illustrate the magnitude and seasonality of radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both shortwave and longwave measurements. Solutions to these operational problems are proposed that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols.

  6. Discharge status evaluation on external insulation of insulator based on results of ultra-violet radiation measurement and fuzzy reasoning%采用模糊推理对绝缘子放电紫外检测结果进行外绝缘放电状况评估

    Institute of Scientific and Technical Information of China (English)

    汪金刚; 张作鹏; 龙震泽; 任昌智; 邓旭东; 何为; 杨帆

    2011-01-01

    In this paper, a method based on the fuzzy theory and ultra-violet (UV) radiation measurement to ac cess the discharge status of external insulation of the insulator is presented. In this method, the amount of UV pul ses generated by corona discharge of insulator is measured firstly, while collecting temperature of environment and humidity information, and then the relationship between the inputs is confirmed by analyzing online monitoring da ta, a series of fuzzy sets for fuzzy reasoning is set up, and the membership function is derived, fuzzy inference rules are established. Then the fuzzy reasoning is carried out to estimate the discharge status of external insulation. Final ly, the validity of this method is verified by simulating and analyzing the data detected from the tests of connecting to grid in Simulink.%根据紫外测量法[5]获得的绝缘子放电强度,提出了采用模糊推理对绝缘子外绝缘放电状况进行评估的方法.该方法首先测量绝缘子电晕放电产生的紫外光脉冲数量,同时采集环境温度、湿度信息,根据在线监测的数据分析确定各输入量之同的关系,建立了一系列可用于模糊推理的模糊子集,并对其隶属度函数进行了推导,建立详尽的模糊推理规则,进行模糊推理,判断其外绝缘放电状况.最后,针对现场挂网试验数据,采用simulink进行仿真分析,验证了该方法的有效性.

  7. Evaluation of Cost and Effectiveness of Decontamination Scenarios on External Radiation Exposure in Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Yasutaka, T.; Naito, W. [National Institute of Advanced Industrial Science and Technology (Japan)

    2014-07-01

    Despite the enormous cost associated with radiation decontamination, almost no quantitative assessment has been performed on the relationship between the potential reduction in long-term radiation exposure and the costs of the various decontamination strategies considered for the decontamination areas in Fukushima. In order to establish effective and pragmatic decontamination strategies for use in the radiation contaminated areas in Fukushima, a holistic approach for assessing decontamination strategies, their costs, and long-term external radiation doses is needed. The objective of the present study is to evaluate the cost and effectiveness of decontamination scenarios in the decontamination areas in Fukushima in regard to external radiation exposure. The choice of decontamination strategies in the decontamination areas should be based on a comprehensive analysis of multiple attributes such as radiological, economic, and socio-psychological attributes. The cost and effectiveness of the different decontamination strategies is not sole determinant of the decontamination strategies of the special decontamination area but is one of the most important attributes when making the policy decision. In the current study, we focus on radiological and economic attributes in determining decontamination strategies. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, the analysis of cost suggests that decontamination costs of decontamination in Fukushima was estimated to be up to approximately 5

  8. Hormonal changes after localized prostate cancer treatment. Comparison between external beam radiation therapy and radical prostatectomy.

    Science.gov (United States)

    Planas, J; Celma, A; Placer, J; Maldonado, X; Trilla, E; Salvador, C; Lorente, D; Regis, L; Cuadras, M; Carles, J; Morote, J

    2016-11-01

    To determine the influence of radical prostatectomy (RP) and external beam radiation therapy (EBRT) on the hypothalamic pituitary axis of 120 men with clinically localized prostate cancer treated with RP or EBRT exclusively. 120 patients with localized prostate cancer were enrolled. Ninety two patients underwent RP and 28 patients EBRT exclusively. We measured serum levels of luteinizing hormone, follicle stimulating hormone (FSH), total testosterone (T), free testosterone, and estradiol at baseline and at 3 and 12 months after treatment completion. Patients undergoing RP were younger and presented a higher prostate volume (64.3 vs. 71.1 years, p<0.0001 and 55.1 vs. 36.5 g, p<0.0001; respectively). No differences regarding serum hormonal levels were found at baseline. Luteinizing hormone and FSH levels were significantly higher in those patients treated with EBRT at three months (luteinizing hormone 8,54 vs. 4,76 U/l, FSH 22,96 vs. 8,18 U/l, p<0,0001) while T and free testosterone levels were significantly lower (T 360,3 vs. 414,83ng/dl, p 0,039; free testosterone 5,94 vs. 7,5pg/ml, p 0,018). At 12 months FSH levels remained significantly higher in patients treated with EBRT compared to patients treated with RP (21,01 vs. 8,51 U/l, p<0,001) while T levels remained significantly lower (339,89 vs. 402,39ng/dl, p 0,03). Prostate cancer treatment influences the hypothalamic pituitary axis. This influence seems to be more important when patients with prostate cancer are treated with EBRT rather than RP. More studies are needed to elucidate the role that prostate may play as an endocrine organ. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Measurement of $\\psip$ Radiative Decays

    OpenAIRE

    Ablikim, M.; J.Z. Bai; Ban, Y.; Collaboration, BES

    2006-01-01

    Using 14 million psi(2S) events accumulated at the BESII detector, we report first measurements of branching fractions or upper limits for psi(2S) decays into gamma ppbar, gamma 2(pi^+pi^-), gamma K_s K^-pi^++c.c., gamma K^+ K^- pi^+pi^-, gamma K^{*0} K^- pi^+ +c.c., gamma K^{*0}\\bar K^{*0}, gamma pi^+pi^- p pbar, gamma 2(K^+K^-), gamma 3(pi^+pi^-), and gamma 2(pi^+pi^-)K^+K^- with the invariant mass of hadrons below 2.9GeV/c^2. We also report branching fractions of psi(2S) decays into 2(pi^+...

  10. Development of radiation protection and measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Lee, B. J.; Chung, K. K.; Lee, K. C.; Chung, R. I.; Han, Y. D.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Yoon, K. S.; Jeong, D. Y.; Yoon, S. C.; Yoon, Y. C.; Lee, S. Y.; Kim, J. S.; Seo, K. W. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, J. K.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    1997-07-01

    Reference X-, gamma, beta and neutron radiation fields complying with the ISO and ANSI standards have been established and evaluated to provide a basic technical support in national radiation protection dosimetry program and to provide calibration measurement devices. Personal dose evaluation algorithm has been developed with these reference radiation fields, which comply well with both domestic and the new ANSI N13.11, to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of in vivo bioassay and the resulting internal doses has been developed and verified its performance. It was also evaluated to be equality excellent compared with those being used in foreign countries and used to make a computer code for internal dose evaluation which can be run with PC under the Windows environment. A BOMAB phantom for precise calibration of in vivo system has been also designed, fabricated and test-evaluated. Based on the ALARA concept of the optimization principle of radiation protection, a method for estimating the cost for radiation protection has been studied and an objective monetary cost of detriment due to radiation exposure, called {alpha} value ($/man-Sv) has been derived and proposed based on the Korean socio-economic situation and human risk factors to provide basic data for the radiation protection optimization study in Korea. (author). 100 refs., 104 tabs., 69 figs.

  11. [Dosimetric system for assessing doses received by people occupationally exposed to external sources of ionizing radiation].

    Science.gov (United States)

    Brodecki, Marcin; Domienik, Joanna U; Zmyślony, Marek

    2012-01-01

    The current system of dosimetric quantities has been defined by the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). Complexity of the system implies the physical nature of ionizing radiation, resulting from the presence of different types of radiation of different ionization capabilities, as well as the individual radiation sensitivity of biological material exposed. According to the latest recommendations, there are three types of dosimeter quantities relevant to radiation protection and radiological assessment of occupational exposure. These are the basic quantities, safety quantities and operational quantities. Dose limits for occupational exposure relate directly to the protection quantities, i.e. the equivalent dose and effective dose, while these quantities are practically unmeasurable in real measurement conditions. For this reason, in the system of dosimetric quantities directly measurable operating volumes were defined. They represent equivalents of the protection quantities that allow for a reliable assessment of equivalent and effective dose by conducting routine monitoring of occupational exposure. This paper presents the characteristics of these quantities, their relationships and importance in assessing individual effects of radiation. Also the methods for their implementation in personal and environmental dosimetry were showcased. The material contained in the article is a compendium of essential information about dosimetric quantities with reference to the contemporary requirements of the law, including the changed annual occupational exposure limit for the lens of the eye. The material is especially addressed to those responsible for dosimetry monitoring in the workplace, radiation protection inspectors and occupational health physicians.

  12. External radiation as element of improvement infrared thermography measurements

    Directory of Open Access Journals (Sweden)

    Palomo, A.

    2000-09-01

    Full Text Available Infrared thermography is a very versatile non destructive technique which among other uses, can be applied to the study of moisture in buildings. However, this particular application can present some problems strictly related to the characteristics of the thermocamera device. In this case the available equipment works in the IR range of 2.5 to 5.6 μm. In this part of the spectrum, there exists a small and not very intense band of emission of the water molecules (approximately centered at 2.7 μm, in such a way that detection can be difficult through thermovision. In the present paper, a complementary technique to the IR thermography being able of favouring the emission of water on the mentioned band, has been developed. It enhances the capacity of detection of the instrument. Likewise, the process which takes place in the material has been numerically modelled.

    La termografía infrarroja es una técnica no destructiva, muy versátil, que, entre otras aplicaciones, tiene la de ser capaz de suministrar información en torno a la problemática de las humedades en la edificación. Sin embargo, esta aplicación concreta puede presentar algunos problemas directamente relacionados con las propias características de la termocámara utilizada. En el caso del presente trabajo el equipo de termografía infrarroja manejado trabaja en el rango del espectro IR comprendido entre 2,5 y 5,6 μm. En esta región del espectro existe una pequeña y no muy intensa banda de emisión de las moléculas de agua (aproximadamente centrada en 2,7 μm cuya detección puede no ser fácil a través de la termovisión. En el presente trabajo se ha desarrollado una técnica complementaria a la termografía infrarroja que es capaz de favorecer la intensidad de emisión del agua en la región del espectro antes mencionada. En definitiva, dicha técnica estimula la capacidad de detección de la termocámara. Adicionalmente, el proceso hídrico que tiene lugar en el material ha sido numéricamente modelizado.

  13. Probing Radiation Damage in Plutonium Alloys with Multiple Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    McCall, S K; Fluss, M J; Chung, B W

    2010-04-21

    A material subjected to radiation damage will usually experience changes in its physical properties. Measuring these changes in the physical properties provides a basis to study radiation damage in a material which is important for a variety of real world applications from reactor materials to semiconducting devices. When investigating radiation damage, the relative sensitivity of any given property can vary considerably based on the concentration and type of damage present as well as external parameters such as the temperature and starting material composition. By measuring multiple physical properties, these differing sensitivities can be leveraged to provide greater insight into the different aspects of radiation damage accumulation, thereby providing a broader understanding of the mechanisms involved. In this report, self-damage from {alpha}-particle decay in Pu is investigated by measuring two different properties: magnetic susceptibility and resistivity. The results suggest that while the first annealing stage obeys second order chemical kinetics, the primary mechanism is not the recombination of vacancy-interstitial close pairs.

  14. External gamma radiation and mortality from cardiovascular diseases in the German WISMUT uranium miners cohort study, 1946-2008

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzer, M.; Dufey, F.; Sogl, M.; Schnelzer, M.; Walsh, L. [Federal Office for Radiation Protection, Department of Radiation Protection and Health, Neuherberg (Germany)

    2013-03-15

    It is currently unclear whether exposure of the heart and vascular system, at lifetime accumulated dose levels relevant to the general public (<500 mGy), is associated with an increased risk of cardiovascular disease. Therefore, data from the German WISMUT cohort of uranium miners were investigated for evidence of a relationship between external gamma radiation and death from cardiovascular diseases. The cohort comprises 58,982 former employees of the Wismut company. There were 9,039 recorded deaths from cardiovascular diseases during the follow-up period from 1946 to 2008. Exposures to external gamma radiation were estimated using a detailed job-exposure matrix. The exposures were based on expert ratings for the period 1946-1954 and measurements thereafter. The excess relative risk (ERR) per unit of cumulative gamma dose was obtained with internal Poisson regression using a linear ERR model with baseline stratification by age and calendar year. The mean cumulative gamma dose was 47 mSv for exposed miners (86 %), with a maximum of 909 mSv. No evidence for an increase in risk with increasing cumulative dose was found for mortality from all cardiovascular diseases (ERR/Sv = -0.13; 95 % confidence interval (CI): -0.38; 0.12) and ischemic heart diseases (n = 4,613; ERR/Sv = -0.03; 95 % CI: -0.38, 0.32). However, a statistically insignificant increase (n = 2,073; ERR/Sv = 0.44; 95 % CI: -0.16, 1.04) for mortality from cerebrovascular diseases was observed. Data on smoking, diabetes, and overweight are available for subgroups of the cohort, indicating no major correlation with cumulative gamma radiation. Confounding by these factors or other risk factors, however, cannot be excluded. In conclusion, the results provide weak evidence for an increased risk of death due to gamma radiation only for cerebrovascular diseases. (orig.)

  15. Measurement of Radiated Power Loss on EAST

    Institute of Scientific and Technical Information of China (English)

    段艳敏; 王亮; 胡立群; 毛松涛; 许平; 陈开云; 林士耀; 钟国强; 张继宗; 张凌

    2011-01-01

    A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (〈0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.

  16. The validity of skin care protocols followed by women with breast cancer receiving external radiation.

    Science.gov (United States)

    Aistars, Juli

    2006-08-01

    Skin care in women receiving external radiation to the breast varies among institutions. Studies have been conducted looking at the effect that various skin care products have on the onset and severity of radiation-induced skin reactions in those patients. Results show that no significant difference exists among these products. The practice of avoiding aluminum-based deodorant on the treated side and avoiding use of any skin care products four hours prior to treatment is not evidence based but often is part of skin care protocols for women receiving breast irradiation. A review of the literature since 1996 in the United States, Canada, United Kingdom, and Australia revealed some evidence to refute the practice but no supporting evidence. Because minimal disruption in a woman's normal hygiene routine could mitigate anxiety and improve coping during a time of extreme stress brought on by a cancer diagnosis, further research is warranted to support changing the practice.

  17. Role of the UV external radiation field on the presence of astrophysical ices in protostellars environments

    Science.gov (United States)

    Robson Monteiro Rocha, Will; Pilling, Sergio

    2016-07-01

    The astrophysical ices survival is directly related with the temperature and ionizing radiation field in protostellars environments such as disks and envelopes. Computational models has shown that pure volatile molecules like CO and CH _{4} should survive only inside densest regions of molecular clouds or protoplanetary disks On the other hand, solid molecules such as H _{2}O and CH _{3}OH can be placed around 5 - 10 AU from the central protostar. Unlike of the previous models, we investigate the role of the UV external radiation field on the presence of ices in disks and envelopes. Once that a star-forming region is composed by the formation of many protostars, the external radiation field should be an important component to understand the real localization of the ices along the sight line. To address this topic it was employed the radiative transfer code RADMC-3D based on the Monte Carlo method. The code was used to model the spectrum and the near-infrared image of Elias 29. The initial parameters of the disk and envelope was taken from our previous paper (Rocha & Pilling (2015), ApJ 803:18). The opacities of the ices were calculated from the complex refractive index obtained at laboratory experiments perfomed at Grand Accélerateur National d'Íons Lourds (GANIL), by using the NKABS code from Rocha & Pilling (2014), SAA 123:436. The partial conclusions that we have obtained shows that pure CO volatile molecule cannot be placed at disk or envelope of Elias 29, unlike shown in our paper about Elias 29. Once it was observed in Elias 29 spectrum obtained with Infrared Space Observatory (ISO) between 2.5 - 190 μm, this molecule should be placed in foreground molecular clouds or trapped in the water ice matrix. The next calculations will be able to show where are placed the ices such as CH _{3}OH and CH _{3}CHO observed in Elias 29 spectrum.

  18. Evaluation of Arctic broadband surface radiation measurements

    Directory of Open Access Journals (Sweden)

    N. Matsui

    2012-02-01

    Full Text Available The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW and thermal infrared, or longwave (LW, radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse SW measurements. The difference between these two quantities (that theoretically should be zero is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.

  19. Osteochondromas and growth retardation secondary to externally or internally administered radiation in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Marcovici, Peter A. [UCSD Medical Center, Department of Radiology, San Diego, CA (United States); Berdon, Walter E. [Morgan Stanley Children' s Hospital of New York, Department of Radiology, New York, NY (United States); Liebling, Melissa S. [Hackensack University Medical Center, Department of Radiology, Hackensack, NJ (United States)

    2007-03-15

    For over five decades, osteochondromas (exostoses) and associated growth retardation have been known to be caused by radiation damage to the growing skeleton.Patients can be divided into three exposure groups. Group I received external beam radiation therapy primarily for the treatment of childhood cancers (typical dose 3,500 cGy), and 6-20% developed osteochondromas and growth retardation within the radiation portal. Group II consists of recently described patients who received total body irradiation in preparation for bone marrow transplant (typical dose: 800-1,200 cGy), and about 20% developed osteochondromas and growth retardation. Group III consists of 206 German children who in the 1940s and early 1950s received intravenous radioactive Peteosthor (Ra-224) to treat bone tuberculosis (estimated typical dose: 1,000-2,000 cGy), and 14% developed osteochondromas and growth retardation, among other benign and malignant sequelae. Combining these three exposure groups, osteochondromas and growth retardation develop in at least 6-20% of children who receive therapeutic radiation to their growing skeletons. (orig.)

  20. Summary of Building Protection Factor Studies for External Exposure to Ionizing Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, Michael B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kane, Jave [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nasstrom, John [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Homann, Steve [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pobanz, Brenda [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-02-17

    Radiation dose assessments are used to help inform decisions to minimize health risks in the event of an atmospheric release of radioactivity including, for example, from a Radiological Dispersal Device, an Improvised Nuclear Device detonation, or a Nuclear Power Plant accident. During these incidents, radiation dose assessments for both indoor and outdoor populations are needed to make informed decisions. These dose assessments inform emergency plans and decisions including, for example, identifying areas in which people should be sheltered and determining when controlled population evacuations should be made. US dose assessment methodologies allow consideration of the protection, and therefore dose reduction, that buildings provide their occupants. However, these methodologies require an understanding of the protection provided by various building types that is currently lacking. To help address this need, Lawrence Livermore National Laboratory, in cooperation with Sandia National Laboratories and the Nuclear Regulatory Commission, was tasked with (a) identifying prior building protection studies, (b) extracting results relevant to US building construction, and (c) summarizing building protection by building type. This report focuses primarily on the protection against radiation from outdoor fallout particles (external gamma radiation).

  1. Points to be noted in using radiation treatment planning system; External photon beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Irifune, Toraji (Tokyo Metropolitan Coll. of Allied Medical Sciences (Japan))

    1993-09-01

    The accuracy of absorbed dose calculations for external photon beam therapy depends on the computational algorithms being used: the acquisition of basic beam data, the patient's anatomical information, the spacing of the points in the matrices, the interpolation routine, inhomogeneity corrections, etc. At present, the dose calculation algorithms employed in most commercially available treatment planning systems for absorbed dose calculation are two-dimensional methods for photon fluence and do not take electronic equilibrium into account. Therefore, their use for radiation treatment planning is limited. In particular, the problem of inhomogeneity correction for lung is the most significant. The inhomogeneity correction methods most commonly used are ratio of TAR (RTAR), power law TAR (PTAR) and equivalent TAR (ETAR) methods. One Japanese society for therapeutic radiology and oncology (JASTRO) task group has compared the three correction methods mentioned above with measured values using the same JARP level dosimeter and lung model phantom. The photon energies were [sup 60]Co [gamma] rays, 4, 6, 10 and 18 MV x rays, and field sizes were 5 x 5, 10 x 10 and 20 x 20 cm[sup 2] at SSD 100 cm. RTAR lead to errors (%) of 2.5 to 12.6, 1.7 to 10.9, 2.7 to 8.5, 3.1 to 9.9, and 1.0 to 19.1; PTAR errors were -0.7 to 2.3, -2.1 to 1.6, -1.1 to 2.2, -0.3 to 3.9, and -2.0 to 6.6; and ETAR errors were 0.7 to 2.5, 0 to 3.1, -0.1 to 6.8, 3.4 to 9.2, and 1.0 to 18.6 for [sup 60]Co [gamma] rays, 4, 6, 10 and 18 MV x rays, respectively. Survey results showed that about 50% of the institutions used measured data obtained by themselves. Basic beam data acquisition should be self-contained. (author).

  2. The patient radiation protection in external radiotherapy: specificity and methods; La radioprotection du patient en radiotherapie externe: specificites et methodes

    Energy Technology Data Exchange (ETDEWEB)

    Beauvais March, H. [Hopital Val de Grace, 75 - Paris (France)

    1999-07-01

    The daily use of high level radiation doses to fight against carcinomas has often led to consider radiation protection as a marginal problem, in this area. But the therapeutic advances, by increasing the life time and life quality have made the side effects unacceptable and revealed the appearance of radioinduced carcinomas. So, it is necessary to practice a patient radiation protection. The general principles of radiation protection are applicable to radiotherapy. (justification, optimization and dose limit, planning of the treatment, quality control of installations). (N.C.)

  3. Web based Measurement System for Solar Radiation

    Directory of Open Access Journals (Sweden)

    Shachi Awasthi

    2012-06-01

    Full Text Available We present in this paper, the principles of the measurement system for solar radiation, and our implementation using Web based data logging concept. The photocurrent produced by Silicon PN junction is used as a solar radiation transducer, to make it more viable we have used commercially available solar panels as our transducers. Using a silicon solar cell as sensor, a low cost solar radiometer can be constructed. The photocurrent produced by solar cell is electronically tailored to be measured and stored by our web based data acquisition and monitoring system. Measurement using real solar cell array gives a good measure of actual producible energy by solar arrays. Our portable instrument can be used in remote sites and substitutes the solar monitor and integrator, Current data of solar radiation can be monitored using Ethernet interface available in all PC, Laptops. We store the data into a secure digital card which can be retrieved to plot and analyse the data. We have developed system hardware and software based on ATmega32 AVR Microcontrollers and ENC28J60 Ethernet PHY and MAC network interface chip by Microchip. So the global irradiance data are obtained after correction using the instantaneous measurement of ambient temperature which allows us to calculate the junction temperature and consequently improve the precision of measurement of our data acquisition system.

  4. Hypofractionated external-beam radiation therapy (HEBRT versus conventional external-beam radiation (CEBRT in patients with localized prostate cancer: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Botrel TEA

    2013-03-01

    Full Text Available Tobias Engel Ayer Botrel,1 Otávio Clark,1 Antônio Carlos Lima Pompeo,2 Francisco Flávio Horta Bretas,2 Marcus Vinicius Sadi,2 Ubirajara Ferreira,2 Rodolfo Borges dos Reis21CoBEU and Evidencias, 2Comitê Brasileiro de Estudos em Uro-Oncologia – CoBEU, BrazilBackground: The purpose of this work was to conduct a systematic review and meta-analysis of all randomized controlled trials comparing the efficacy and side effect profile of hypofractionated versus conventional external-beam radiation therapy for prostate cancer.Methods: Several databases were searched, including Medline, EmBase, LiLACS, and Central. The endpoints were freedom from biochemical failure and side effects. We performed a meta-analysis of the published data. The results are expressed as the hazard ratio (HR or risk ratio (RR, with the corresponding 95% confidence interval (CI.Results: The final analysis included nine trials comprising 2702 patients. Freedom from biochemical failure was reported in only three studies and was similar in patients who received hypofractionated or conventional radiotherapy (fixed effect, HR 1.03, 95% CI 0.88–1.20; P = 0.75, with heterogeneity [χ2 = 15.32, df = 2 (P = 0.0005; I2 = 87%]. The incidence of acute adverse gastrointestinal events was higher in the hypofractionated group (fixed effect, RR 2.02, 95% CI 1.45–2.81; P < 0.0001. We also found moderate heterogeneity on this analysis [χ2 = 7.47, df = 5 (P = 0.19; I2 = 33%]. Acute genitourinary toxicity was similar among the groups (fixed effect, RR 1.19, 95% CI 0.95–1.49; P = 0.13, with moderate heterogeneity [χ2 = 5.83, df = 4 (P = 0.21; I2 = 31%]. The incidence of all late adverse events was the same in both groups (fixed effect, gastrointestinal toxicity, RR 1.17, 95% CI 0.79–1.72, P = 0.44; and acute genitourinary toxicity, RR 1.16, 95% CI 0.80–1.68, P = 0.44.Conclusion: Hypofractionated radiotherapy in localized prostate cancer was not superior to conventional radiotherapy and

  5. Statistical Modeling of the Eye for Multimodal Treatment Planning for External Beam Radiation Therapy of Intraocular Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rueegsegger, Michael B. [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland); Bach Cuadra, Meritxell [Department of Radiology, University Hospital Center (CHUV) and University of Lausanne (UNIL), Signal Processing Laboratory - LTS5, Ecole Polytechnique Federale de Lausanne (Switzerland); Pica, Alessia [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Amstutz, Christoph A. [Department of Ophthalmology, University Hospital Zurich (Switzerland); Rudolph, Tobias [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland); Aebersold, Daniel [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Kowal, Jens H., E-mail: jens.kowal@artorg.unibe.ch [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland)

    2012-11-15

    Purpose: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Methods and Materials: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Results: Cross-validation revealed a dice similarity of 95% {+-} 2% for the sclera and cornea and 91% {+-} 2% for the lens. Overall, mean segmentation error was found to be 0.3 {+-} 0.1 mm. Average segmentation time was 14 {+-} 2 s on a standard personal computer. Conclusions: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

  6. Absorbed dose measurements on external surface of Kosmos-satellites with glass thermoluminescent detectors.

    Science.gov (United States)

    Akatov YuA; Arkhangelsky, V V; Kovalev, E E; Spurny, F; Votochkova, I

    1989-01-01

    In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.

  7. Measuring the Value of Externalities from Higher Education

    Science.gov (United States)

    Chapman, Bruce; Lounkaew, Kiatanantha

    2015-01-01

    This paper takes an innovative approach. We have used the idea of converting international evidence of the size of higher education externalities as a proportion of GDP into Australian-specific dollar equivalents and added these estimates to estimates of lifetime fiscal returns to graduates. This allows us to estimate the expected spillovers over…

  8. Effects of external gamma radiation on femoral artery reimplantation in rats: morphometrical analyzes

    Directory of Open Access Journals (Sweden)

    Costa Regina de Faria Bittencourt da

    2003-01-01

    Full Text Available PURPOSE: To investigate the effects of external gamma radiation on rat femoral artery reimplant. METHODS: Sixty-two male Wistar rats were distributed in two groups I (Control and II (Irradiated, both formed by three observation subgroups: 2 (10 animals, 7 (11 and 21(10 postoperative days (PO. The right femoral artery of each animal was split up and reimplanted (end-to-end anastomosis, through microsurgery technique. In the first PO day group II animals were irradiated with a single dose of 15Gy, external source. The histological analysis, qualitative and descriptive analysis, was accomplished through hematoxylin and eosin (HE, Verhoeff and Masson trichromium methodology. Morphometric analysis was realized in the same slides used to histological analysis stained by HE. Computer software was used to quantify morphological alterations of the vascular wall, by processing captured images from a microscope. It was analyzed the intimal layer (intimal hyperplasia and endothelium cells formation and the nuclei percentage of smooth muscular cell in the medium layer and in the intima hyperplasia. The data were treated applying the statistical tests: Fisher's exact, Chi-square, Mann-Whitney, Kruskal-Wallis and analysis of variance (p < .05. RESULTS: The patency graft was observed by microscope distal to the autograft in 93.5% (29/31. It was observed that the gamma-radiation reduced the degree of covering of the vascular wall for the neo-formed endothelium. The nuclei percentage of smooth muscular cells, in the media, was smaller compared to control animals, although it was no significant for the studied sample size. The irradiated group showed a significant lower luminal stenosis and the intimal hyperplasia occurrence. In this group the percentage of smooth muscular cells proliferation, in the media, were significantly lower for 7 and 21 days of observation. CONCLUSION: The external single dose of 15 Gy gamma-radiation delivered at first postoperative day

  9. Measuring Earth's Radiation Imbalance using Cubesat Constellations

    Science.gov (United States)

    Collins, W. D.; Courtade, S.; Immel, T. J.; Feldman, D.; Lorentz, S. R.; Dyrud, L. P.

    2016-12-01

    At present, the global annual-mean Earth Radiation Imbalance (ERI) is estimated to be of order 1 W/m2, although the uncertainty in ERI is much larger than this estimate. The best current satellite-only observational determinations of ERI range from -2 to +7 W/m2 unless major adjustments are made using ocean observations. Since measurements of ERI accurate to better than 0.5 W/m2 are essential for understanding and predicting changes in our climate, new missions to determine ERI in conjunction with ongoing ocean observations are urgently needed. These missions should reliably determine Earth's radiation balance at the temporal and spatial scales sufficient for relating ERI to the physical processes responsible for variability. The compelling objective of measuring ERI can be met using a constellation of satellites making global, high-frequency radiation measurements of the solar energy reflected and infrared energy radiated back to space with sufficient accuracy to determine the ERI to within 0.5 W/m2. In this presentation, we discuss the reasons and prospects for deploying a Cubesat constellation to realize this objective, simulations of the data that could be produced by this constellation, and the advantages of the spatial coverage and high temporal frequency afforded by the constellation. These advantages apply both to estimating long-term ERI and to quantifying the radiation budgets of individual synoptic-scale weather systems. The innovations in this system involve both the use of Cubesats and of compact, continuously calibrated wide-field-of-view radiometers. We demonstrate the feasibility of such a constellation using the ongoing proof-of-concept deployment of the target radiometers onboard the upcoming NASA RAVAN (Radiometer Assessment using Vertically Aligned Nanotubes) mission.

  10. Web based Measurement System for Solar Radiation

    Directory of Open Access Journals (Sweden)

    Shachi Awasthi

    2012-06-01

    Full Text Available We present in this paper, the principles of themeasurement system for solar radiation, and ourimplementation using Web based data loggingconcept.The photocurrent produced by Silicon PNjunction is used as a solar radiation transducer, tomake it more viable we have used commerciallyavailable solar panels as our transducers. Using asilicon solar cell as sensor, a low cost solarradiometer can be constructed. The photocurrentproduced by solar cell is electronically tailored to bemeasured and stored by our web based dataacquisition and monitoring system. Measurementusing real solar cell array gives a good measure ofactual producible energy by solar arrays. Ourportable instrument can be used in remote sites andsubstitutes the solar monitor and integrator,Current data of solar radiation can be monitoredusing Ethernet interface available in all PC,Laptops. We store the data into a secure digital cardwhich can be retrieved to plot and analyse the data.We have developed system hardware andsoftware based on ATmega32 AVR Microcontrollersand ENC28J60 Ethernet PHY and MAC networkinterface chip by Microchip.So the global irradiance data are obtained aftercorrection using the instantaneous measurement ofambient temperature which allows us to calculatethe junction temperature and consequently improvethe precision of measurement of our dataacquisition system

  11. An inventory of measures for internalising external costs in transport

    Energy Technology Data Exchange (ETDEWEB)

    Van Essen, H.; Nelissen, D.; Smit, M.; Van Grinsven, A.; Aarnink, S. [CE Delft, Delft (Netherlands); Breemersch, T. [Transport and Mobility Leuven TML, Leuven (Belgium); Martino, A.; Rosa, C.; Parolin, R. [Trasporti e Territorio TRT, Brussels (Belgium); Harmsen, J. [Sustainable Transport and Logistics TNO, Rotterdam (Netherlands)

    2012-11-15

    This study provides an overview of all existing and close to implementation pricing policies in transport. It supported the European Commission with the evaluation of existing pricing policies in the light of Article 11.4 of the revised Eurovignette Directive. The study covers all existing pricing instruments in all transport modes in all EU Member States. In addition it includes data on revenues and administrative costs and some comparisons across Member States and transport modes. The most recent data have been gathered: data for 2010 and where possible 2011. Also the link with external and infrastructure costs is discussed, and where possible, high level comparisons have been made.

  12. Measuring ionizing radiation with a mobile device

    Science.gov (United States)

    Michelsburg, Matthias; Fehrenbach, Thomas; Puente León, Fernando

    2012-02-01

    In cases of nuclear disasters it is desirable to know one's personal exposure to radioactivity and the related health risk. Usually, Geiger-Mueller tubes are used to assess the situation. Equipping everyone with such a device in a short period of time is very expensive. We propose a method to detect ionizing radiation using the integrated camera of a mobile consumer device, e.g., a cell phone. In emergency cases, millions of existing mobile devices could then be used to monitor the exposure of its owners. In combination with internet access and GPS, measured data can be collected by a central server to get an overview of the situation. During a measurement, the CMOS sensor of a mobile device is shielded from surrounding light by an attachment in front of the lens or an internal shutter. The high-energy radiation produces free electrons on the sensor chip resulting in an image signal. By image analysis by means of the mobile device, signal components due to incident ionizing radiation are separated from the sensor noise. With radioactive sources present significant increases in detected pixels can be seen. Furthermore, the cell phone application can make a preliminary estimate on the collected dose of an individual and the associated health risks.

  13. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  14. Noninvasive referencing of intraocular tumors for external beam radiation therapy using optical coherence tomography: A proof of concept

    Energy Technology Data Exchange (ETDEWEB)

    Rüegsegger, Michael B.; Steiner, Patrick; Kowal, Jens H., E-mail: jens.kowal@artorg.unibe.ch [ARTORG Center for Biomedical Engineering Research, University of Bern, Bern 3010 (Switzerland); Geiser, Dominik [Berne University of Applied Sciences, HuCE OptoLab, 2501 (Switzerland); Pica, Alessia; Aebersold, Daniel M. [Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern 3010 (Switzerland)

    2014-08-15

    Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

  15. Photocatalytic Active Radiation Measurements and Use

    Science.gov (United States)

    Davis, Bruce A.; Underwood, Lauren W.

    2011-01-01

    Photocatalytic materials are being used to purify air, to kill microbes, and to keep surfaces clean. A wide variety of materials are being developed, many of which have different abilities to absorb various wavelengths of light. Material variability, combined with both spectral illumination intensity and spectral distribution variability, will produce a wide range of performance results. The proposed technology estimates photocatalytic active radiation (PcAR), a unit of radiation that normalizes the amount of light based on its spectral distribution and on the ability of the material to absorb that radiation. Photocatalytic reactions depend upon the number of electron-hole pairs generated at the photocatalytic surface. The number of electron-hole pairs produced depends on the number of photons per unit area per second striking the surface that can be absorbed and whose energy exceeds the bandgap of the photocatalytic material. A convenient parameter to describe the number of useful photons is the number of moles of photons striking the surface per unit area per second. The unit of micro-einsteins (or micromoles) of photons per m2 per sec is commonly used for photochemical and photoelectric-like phenomena. This type of parameter is used in photochemistry, such as in the conversion of light energy for photosynthesis. Photosynthetic response correlates with the number of photons rather than by energy because, in this photochemical process, each molecule is activated by the absorption of one photon. In photosynthesis, the number of photons absorbed in the 400 700 nm spectral range is estimated and is referred to as photosynthetic active radiation (PAR). PAR is defined in terms of the photosynthetic photon flux density measured in micro-einsteins of photons per m2 per sec. PcAR is an equivalent, similarly modeled parameter that has been defined for the photocatalytic processes. Two methods to measure the PcAR level are being proposed. In the first method, a calibrated

  16. Dosimetry for the external radiation therapy. Dosimetry with alanine; Dosimetrie fuer die externe Strahlentherapie. Dosimetrie mit Alanin

    Energy Technology Data Exchange (ETDEWEB)

    Anton, Mathias [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe ' Alanin-Dosimetrie'

    2013-06-15

    The alanine-ESR dosimetry in the PTB is described. The response power of alanine related to the water energy dose for X-rays with average energy of 10-1000 keV is presented. Furthermore the application of alanine for the quality assurance in the radiation therapy is described by means of the prostate irradiation and the therapy of a tumor in the neck region as examples. (HSI)

  17. Quality assurance in personal dosimetry of external radiation: present situation and future needs

    Energy Technology Data Exchange (ETDEWEB)

    Ma, N. [Malaysian Institue For Nuclear Technology Research (MINT), Bangi, Selangor (Malaysia)

    2006-07-01

    Whole body personal dosimetry is well established for the individual monitoring of radiation workers. High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The mandate has been given to the Personal Dosimetry, (secondary standard dosimetry laboratories) S.S.D.L., (Malaysian institute for nuclear energy research) M.I.N.T. to assure the individual monitoring for radiation workers in Malaysia. In 2005, the S.S.D.L;-M.I.N.T. supply, process and read out of personal dosemeters of nearly 13,000 dosimeters monthly, whereby. 12,000 are films and 1,000 are T.L.D.s. The objective of individual monitoring is not limited to the measurement of doses delivered to individuals, but it should demonstrate that limits of exposure have not been exceeded and that working conditions have not unexpectedly deteriorated. Dosimetry measurements are an important component of radiation protection programs and must be of high quality. The exposure of workers to radiation must be controlled and monitored in order to comply with regulatory requirements. S.S.D.L.-M.I.N.T; demonstrates that its performance is at an acceptable level by implementing overall system performance, as evidenced by the ISO 9001 certification of the Personal Dosimetry Service in 2002 and ISO/I.E.C. 17025 accreditation to the calibration laboratory in 2004. The certification and accreditation processes achieved the goal by formalizing the recognition of satisfactory performance, and providing evidence of this performance. Overall performances are assessed, personnel operating the system will be trained and are well qualified and all actions will be documented. The paper describes the overview of the Q.M.S. carried out at the S.S. D.L.-M.I.N.T.. During the implementation of Q.M.S. a few areas has been identified for future consideration. These include performance specification and type testing of dosemeters, which provide a

  18. [The role of external beam radiation therapy in the adjuvant treatment of pigmented villonodular synovitis].

    Science.gov (United States)

    Heyd, R; Seegenschmiedt, M H; Micke, O

    2011-12-01

    Pigmented villonodular synovitis (PVNS) is a rare proliferative disorder arising from synovial cells of the tendon sheets and joint capsules. The potential value of external beam radiation therapy in the interdisciplinary management of PVNS is demonstrated by a comprehensive literature review on the clinical use of radiotherapy and the results of national patterns of care study (PCS) which was conducted by the German Cooperative Group on Radiotherapy in Benign Diseases (GCG-BD) in 2008-2009. A structured questionnaire was mailed to all 227 RT institutions in Germany to assess all previous treatments, the RT indication and techniques, the rate of local control, the functional outcome and the possible adverse effects related to the use of external beam radiation therapy (RT). For comparison of the clinical outcome data, a systematic literature research in several international electronic databases and a conventional library search were performed to identify publications addressing the use of RT for PVNS. Based on an overall response rate of 83.2%, the PCS was nationally representative. Ten percent of institutions presented clinical experience with the use of RT for PVNS; from this database a total of 41 treated sites from 14 institutions were evaluable for long-term analysis. The primary therapeutic approach was cytoreductive surgery in all cases. In cases of residual tissue or complete resection of extensive local recurrences, RT was applied in 39 cases (95.1%). An excellent or good functional outcome was noted in 34 cases (82.9%). The use of RT was not associated with early or late toxicity larger than RTOG grade II. The literature review identified 19 published studies (1940-2009) which represented a total of 140 cases or patients, respectively. After follow-up periods ranging from 1-250 months and administration of total doses in the range of 16-50 Gy the overall rate of local control was 84.5%. Both the results of the national PCS and the literature review

  19. ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II

    Directory of Open Access Journals (Sweden)

    Nicholas G. Zaorsky, MD

    2017-07-01

    Conclusions: External beam radiation is a key component of the curative management of T1 and T2 prostate cancer. By combining the most recent medical literature, these Appropriateness Criteria can aid clinicians in determining the appropriate treatment delivery and personalized approaches for individual patients.

  20. Discriminating Gene Expression Signature of Radiation-Induced Thyroid Tumors after Either External Exposure or Internal Contamination

    Directory of Open Access Journals (Sweden)

    Sylvie Chevillard

    2011-12-01

    Full Text Available Both external radiation exposure and internal radionuclide contamination are well known risk factors in the development of thyroid epithelial tumors. The identification of specific molecular markers deregulated in radiation-induced thyroid tumors is important for the etiological diagnosis since neither histological features nor genetic alterations can discriminate between sporadic and radiation-induced tumors. Identification of highly discriminating markers in radiation-induced tumors is challenging as it relies on the ability to identify marker deregulation which is associated with a cellular stress that occurred many years before in the thyroid cells. The existence of such a signature is still controversial, as it was not found in several studies while a highly discriminating signature was found in both post-radiotherapy and post-Chernobyl series in other studies. Overall, published studies searching for radiation-induced thyroid tumor specificities, using transcriptomic, proteomic and comparative genomic hybridization approaches, and bearing in mind the analytical constraints required to analyze such small series of tumors, suggest that such a molecular signature could be found. In comparison with sporadic tumors, we highlight molecular similarities and specificities in tumors occurring after high-dose external radiation exposure, such as radiotherapy, and in post-Chernobyl tumors that occurred after internal 131I contamination. We discuss the relevance of signature extrapolation from series of tumors developing after high and low doses in the identification of tumors induced at very low doses of radiation.

  1. Discriminating gene expression signature of radiation-induced thyroid tumors after either external exposure or internal contamination.

    Science.gov (United States)

    Ory, Catherine; Ugolin, Nicolas; Schlumberger, Martin; Hofman, Paul; Chevillard, Sylvie

    2011-12-21

    Both external radiation exposure and internal radionuclide contamination are well known risk factors in the development of thyroid epithelial tumors. The identification of specific molecular markers deregulated in radiation-induced thyroid tumors is important for the etiological diagnosis since neither histological features nor genetic alterations can discriminate between sporadic and radiation-induced tumors. Identification of highly discriminating markers in radiation-induced tumors is challenging as it relies on the ability to identify marker deregulation which is associated with a cellular stress that occurred many years before in the thyroid cells. The existence of such a signature is still controversial, as it was not found in several studies while a highly discriminating signature was found in both post-radiotherapy and post-Chernobyl series in other studies. Overall, published studies searching for radiation-induced thyroid tumor specificities, using transcriptomic, proteomic and comparative genomic hybridization approaches, and bearing in mind the analytical constraints required to analyze such small series of tumors, suggest that such a molecular signature could be found. In comparison with sporadic tumors, we highlight molecular similarities and specificities in tumors occurring after high-dose external radiation exposure, such as radiotherapy, and in post-Chernobyl tumors that occurred after internal 131I contamination. We discuss the relevance of signature extrapolation from series of tumors developing after high and low doses in the identification of tumors induced at very low doses of radiation.

  2. Radiative lifetime measurements of rubidium Rydberg states

    CERN Document Server

    Branden, Drew B; Mahlokozera, Tatenda; Vesa, Cristian; Wilson, Roy O; Zheng, Mao; Kortyna, Andrew; Tate, Duncan A

    2009-01-01

    We have measured the radiative lifetimes of ns, np and nd Rydberg states of rubidium in the range 28 < n < 45. To enable long-lived states to be measured, our experiment uses slow-moving Rb atoms in a magneto-optical trap (MOT). Two experimental techniques have been adopted to reduce random and systematic errors. First, a narrow-bandwidth pulsed laser is used to excite the target Rydberg state, resulting in minimal shot-to-shot variation in the initial state population. Second, we monitor the target state population as a function of time delay from the laser pulse using a short-duration, millimetre-wave pulse that is resonant with a one- or two-photon transition. We then selectively field ionize the monitor state, and detect the resulting electrons with a micro-channel plate. This signal is an accurate mirror of the target state population, and is uncontaminated by contributions from other states which are populated by black body radiation. Our results are generally consistent with other recent experime...

  3. Uncertainty of dose measurement in radiation processing

    DEFF Research Database (Denmark)

    Miller, A.

    1996-01-01

    The major standard organizations of the world have addressed the issue of reporting uncertainties in measurement reports and certificates. There is, however, still some ambiguity in the minds of many people who try to implement the recommendations in real life. This paper is a contribution...... to the running debate and presents the author's view, which is based upon experience in radiation processing dosimetry. The origin of all uncertainty components must be identified and can be classified according to Type A and Type B, but it is equally important to separate the uncertainty components into those...... that contribute to the observable uncertainty of repeated measurements and those that do not. Examples of the use of these principles are presented in the paper....

  4. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  5. Quantification of an External Motion Surrogate for Quality Assurance in Lung Cancer Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Jens Wölfelschneider

    2014-01-01

    Full Text Available The purpose of this work was to validate the stability of the end exhale position in deep expiration breath hold (DEBH technique for quality assurance in stereotactic lung tumor radiation therapy. Furthermore, a motion analysis was performed for 20 patients to evaluate breathing periods and baseline drifts based on an external surrogate. This trajectory was detected using stereo infrared (IR cameras and reflective body markers. The respiratory waveform showed large interpatient differences in the end exhale position during irradiation up to 18.8 mm compared to the global minimum. This position depends significantly on the tumor volume. Also the baseline drifts, which occur mostly in posterior direction, are affected by the tumor size. Breathing periods, which depend mostly on the patient age, were in a range between 2.4 s and 7.0 s. Fifteen out of 20 patients, who showed a reproducible end exhale position with a deviation of less than 5 mm, might benefit from DEBH due to smaller planning target volumes (PTV compared to free breathing irradiation and hence sparing of healthy tissue. Patients with larger uncertainties should be treated with more complex motion compensation techniques.

  6. The role of adjuvant external beam radiation therapy for papillary thyroid carcinoma invading the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk; Choi, Jae Hyuck; Kim, Kwang Sik [Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); and others

    2017-06-15

    To evaluate the effect of adjuvant external beam radiation therapy (EBRT) on local failure-free survival rate (LFFS) for papillary thyroid cancer (PTC) invading the trachea. Fifty-six patients with locally advanced PTC invading the trachea were treated with surgical resection. After surgery, 21 patients received adjuvant EBRT and radioactive iodine therapy (EBRT group) and 35 patients were treated with radioactive iodine therapy (control group). The age range was 26–87 years (median, 56 years). The median follow-up period was 43 months (range, 4 to 145 months). EBRT doses ranged from 50.4 to 66 Gy (median, 60 Gy). Esophagus invasion and gross residual disease was more frequent in the EBRT group. In the control group, local recurrence developed in 9 (9/35, 26%) and new distant metastasis in 2 (2/35, 6%) patients, occurring 4 to 68 months (median, 37 months) and 53 to 68 months (median, 60 months) after surgery, respectively. Two patients had simultaneous local recurrence and new distant metastasis. There was one local failure in the EBRT group at 18 months after surgery (1/21, 5%). The 5-year LFFS was 95% in the EBRT group and 63% in the control group (p = 0.103). In the EBRT group, one late grade 2 xerostomia was developed. Although, EBRT group had a higher incidence of esophagus invasion and gross residual disease, EBRT group showed a better 5-year LFFS. Adjuvant EBRT may have contributed to the better LFFS in these patients.

  7. Radiated radiofrequency immunity testing of automated external defibrillators - modifications of applicable standards are needed

    Directory of Open Access Journals (Sweden)

    Bassen Howard I

    2011-07-01

    Full Text Available Abstract Background We studied the worst-case radiated radiofrequency (RF susceptibility of automated external defibrillators (AEDs based on the electromagnetic compatibility (EMC requirements of a current standard for cardiac defibrillators, IEC 60601-2-4. Square wave modulation was used to mimic cardiac physiological frequencies of 1 - 3 Hz. Deviations from the IEC standard were a lower frequency limit of 30 MHz to explore frequencies where the patient-connected leads could resonate. Also testing up to 20 V/m was performed. We tested AEDs with ventricular fibrillation (V-Fib and normal sinus rhythm signals on the patient leads to enable testing for false negatives (inappropriate "no shock advised" by the AED. Methods We performed radiated exposures in a 10 meter anechoic chamber using two broadband antennas to generate E fields in the 30 - 2500 MHz frequency range at 1% frequency steps. An AED patient simulator was housed in a shielded box and delivered normal and fibrillation waveforms to the AED's patient leads. We developed a technique to screen ECG waveforms stored in each AED for electromagnetic interference at all frequencies without waiting for the long cycle times between analyses (normally 20 to over 200 s. Results Five of the seven AEDs tested were susceptible to RF interference, primarily at frequencies below 80 MHz. Some induced errors could cause AEDs to malfunction and effectively inhibit operator prompts to deliver a shock to a patient experiencing lethal fibrillation. Failures occurred in some AEDs exposed to E fields between 3 V/m and 20 V/m, in the 38 - 50 MHz range. These occurred when the patient simulator was delivering a V-Fib waveform to the AED. Also, we found it is not possible to test modern battery-only-operated AEDs for EMI using a patient simulator if the IEC 60601-2-4 defibrillator standard's simulated patient load is used. Conclusions AEDs experienced potentially life-threatening false-negative failures from

  8. External meeting - Geneva University: Semileptonic and Radiative B-meson decays

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 - Tél : 022 379 62 73 - Fax: 022 379 69 92 Wednesday 4 April 2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium Semileptonic and Radiative B-meson decays by Dr Antonio Limosani / K2K, Japon The success of the B Factories at KEK and SLAC has furthered our knowledge of CP violation, a necessary ingredient for the creation of a matter-dominanted universe. Ever increasing data samples has ushered in a new era of precision CP measurements, in which the unitarity of the Cabibbo-Kobayashi-Maskawa matrix is examined for signs of New Physics. One of the crucial pieces of information, surprisingly, comes not from CP violation but from studies of semileptonic decays of the B mesons. I will discuss how various measurements of semileptonic and radiative B decays combine together to provide a precision measurement of the CKM matrix element |Vcb| and to determine the value of s...

  9. Measurement of the external parameters in quantitative active thermography

    Science.gov (United States)

    Olmi, R.; Inglese, G.

    2017-10-01

    Infrared thermography is widely used in non-destructive testing and in the non-destructive evaluation of subsurface defects in several materials. The detection and reconstruction (location and shape) of a defect inside a material from thermal data requires the solution of an inverse heat conduction problem. Here the problem is tackled by the thin-plate approximation of the investigated domain. A number of physical quantities must be known for the reconstruction procedure to be successful: some relating to the material (thermal conductivity, heat capacity, density), usually known, and others relating to the heating process. This paper proposes procedures for accurately measuring the latter, whose importance is often not given due consideration. Those procedures allow us to accurately measure the heat flux distribution produced by the sources on the heated surface, and the heat exchange coefficient at the remaining surfaces, and are easily applicable in ‘on field’ situations.

  10. Determining Transmission Loss from Measured External and Internal Acoustic Environments

    Science.gov (United States)

    Scogin, Tyler; Smith, A. M.

    2012-01-01

    An estimate of the internal acoustic environment in each internal cavity of a launch vehicle is needed to ensure survivability of Space Launch System (SLS) avionics. Currently, this is achieved by using the noise reduction database of heritage flight vehicles such as the Space Shuttle and Saturn V for liftoff and ascent flight conditions. Marshall Space Flight Center (MSFC) is conducting a series of transmission loss tests to verify and augment this method. For this test setup, an aluminum orthogrid curved panel representing 1/8th of the circumference of a section of the SLS main structure was mounted in between a reverberation chamber and an anechoic chamber. Transmission loss was measured across the panel using microphones. Data measured during this test will be used to estimate the internal acoustic environments for several of the SLS launch vehicle internal spaces.

  11. Method and apparatus for measuring electromagnetic radiation

    Science.gov (United States)

    Been, J. F. (Inventor)

    1973-01-01

    An apparatus and method are described in which the capacitance of a semiconductor junction subjected to an electromagnetic radiation field is utilized to indicate the intensity or strength of the radiation.

  12. SUMER: Solar Ultraviolet Measurements of Emitted Radiation

    Science.gov (United States)

    Wilhelm, K.; Axford, W. I.; Curdt, W.; Gabriel, A. H.; Grewing, M.; Huber, M. C. E.; Jordan, M. C. E.; Lemaire, P.; Marsch, E.; Poland, A. I.

    1988-01-01

    The SUMER (solar ultraviolet measurements of emitted radiation) experiment is described. It will study flows, turbulent motions, waves, temperatures and densities of the plasma in the upper atmosphere of the Sun. Structures and events associated with solar magnetic activity will be observed on various spatial and temporal scales. This will contribute to the understanding of coronal heating processes and the solar wind expansion. The instrument will take images of the Sun in EUV (extreme ultra violet) light with high resolution in space, wavelength and time. The spatial resolution and spectral resolving power of the instrument are described. Spectral shifts can be determined with subpixel accuracy. The wavelength range extends from 500 to 1600 angstroms. The integration time can be as short as one second. Line profiles, shifts and broadenings are studied. Ratios of temperature and density sensitive EUV emission lines are established.

  13. Thyroid cancer in the Marshallese: relative risk of short-lived internal emitters and external radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Lessard, E.T.; Brill, A.B.; Adams, W.H.

    1985-01-01

    In a study of the comparative effects of internal versus external irradiation of the thyroid in young people, we determined that the dose from internal irradiation of the thyroid with short-lived internal emitters produced several times less thyroid cancer than did the same dose of radiation given externally. We determined this finding for a group of 85 Marshall Islands children, who were less than 10 years of age at the time of exposure and who were accidentially exposed to internal and external thyroid radiation at an average level of 1400 rad. The external risk coefficient ranged between 2.5 and 4.9 cancers per million person-rad-years at risk, and thus, from our computations, the internal risk coefficient for the Marshallese children was estimated to range between 1.0 and 1.4 cancers per million person-rad-years at risk. In contrast, for individual more than 10 years of age at the time of exposure, the dose from internal irradiation of the thyroid with short-lived internal emitters produced several times more thyroid cancer than did the same dose of radiation given externally. The external risk coefficients for the older age groups were reported in the literature to be in the range of 1.0 to 3.3 cancers per million person-rad-years-at risk. We computed internal risk coefficients of 3.3 to 8.1 cancers per million person-rad-years at risk for adolescent and adult groups. This higher sensitivity to cancer induction in the exposed adolescents and adults, is different from that seen in other exposed groups. 14 refs., 8 tabs.

  14. Plasma response measurements of external magnetic perturbations using electron cyclotron emission and comparisons to 3D ideal MHD equilibrium

    CERN Document Server

    Willensdorfer, M; Strumberger, E; Suttrop, W; Vanovac, B; Brida, D; Cavedon, M; Classen, I; Dunne, M; Fietz, S; Fischer, R; Kirk, A; Laggner, F M; Liu, Y Q; Odstrcil, T; Ryan, D A; Viezzer, E; Zohm, H; Luhmann, I C

    2016-01-01

    The plasma response from an external n = 2 magnetic perturbation field in ASDEX Upgrade has been measured using mainly electron cyclotron emission (ECE) diagnostics and a rigid rotating field. To interpret ECE and ECE-imaging (ECE-I) measurements accurately, forward modeling of the radiation transport has been combined with ray tracing. The measured data is compared to synthetic ECE data generated from a 3D ideal magnetohydrodynamics (MHD) equilibrium calculated by VMEC. The measured amplitudes of the helical displacement in the midplane are in reasonable agreement with the one from the synthetic VMEC diagnostics. Both exceed the vacuum field calculations and indicate the presence of an amplified kink response at the edge. Although the calculated magnetic structure of this edge kink peaks at poloidal mode numbers larger than the resonant components |m| > |nq|, the displacement measured by ECE-I is almost resonant |m| ~ |nq|. This is expected from ideal MHD in the proximity of rational surfaces. VMEC and MARS-...

  15. External meeting - Geneva University: Precision measurements in spin physics

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 - Tél: 022 379 62 73 - Fax: 022 379 69 92 Wednesday 28 March 2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium Precision measurements in spin physics by Dr. Steven Bass / CERN - Innsbruck The proton spin problem has been challenging experimentalists and theorists alike for the last 20 years. Polarized deep inelastic scattering experiments at CERN, DESY and SLAC have told us that quark partons contribute only about 30% of the proton's spin whereas relativistic quark models predict 60%. Where is the missing spin and why is the quark spin contribution so small? In this talk I will give an overview of the proton spin problem and what it may be telling us about QCD, the vacuum and dynamical symmetry breaking. A precise measurement of neutrino-proton elastic scattering would make a vital contribution to resolving many of the outstanding issues. Information: http://dpnc...

  16. Measuring radiative capture rates at DRAGON

    Science.gov (United States)

    Hager, U.; Davids, B.; Fallis, J.; Greife, U.; Hutcheon, D. A.; Rojas, A.; Ruiz, C.

    2013-04-01

    The DRAGON recoil separator facility is located at the ISAC facility at TRIUMF, Vancouver. It is designed to measure radiative alpha and proton capture reactions of astrophysical importance in inverse kinematics. The Supernanogan ion source at ISAC provides stable beams of high intensities. The DRAGON collaboration has taken advantage of this over the last years by measuring several reactions requiring high-intensity stable oxygen beams. In particular,the ^17O(p,γ) and ^16O(α,γ) reaction rates were recently measured. The former reaction is part of the hot CNO cycle, and strongly influences the abundance of ^18F in classical novae. Because of its relatively long lifetime, ^18F is a possible target for satellite-based gamma-ray spectroscopy. The ^16O(α,γ) reaction plays a role in steady-state helium burning in massive stars, where it follows the ^12C(α,γ) reaction. At astrophysically relevant energies, the reaction proceeds exclusively via direct capture, resulting in a low rate. In both cases, the unique capabilities of DRAGON enabled determination not only of the total reaction rates, but also of decay branching ratios. Results from both experiments will be presented.

  17. Revised series of stylized anthropometric phantoms for internal and external radiation dose assessment

    Science.gov (United States)

    Han, Eunyoung

    At present, the dosimetry systems of both the International Commission on Radiological Protection, and the Society of Nuclear Medicine's Medical Internal Radiation Dose Committee utilize a series of stylized or mathematical anthropometric models of patient anatomy developed in 1987 at the Oak Ridge National Laboratory (ORNL). In this study, substantial revisions to the ORNL phantom series are reported with tissue compositions, tissue densities, and organ masses adjusted to match their most recent values in the literature. In addition, both the ICRP and MIRD systems of internal dosimetry implicitly consider that electron and beta-particle energy emitted within the source organs of the patient are fully deposited within these organs. With the development of the revised ORNL phantom series, three additional applications were explored as part of this dissertation research. First, the phantoms were used in combination to assess external radiation exposures to family members caring or interacting with patients released from the hospital following radionuclide therapy with I-131. Values of family member effective dose are then compared to values obtained using NRC guidance and based on a simple point-source methodology which ignores the effects of photon attenuation and scatter within both the source individual (patient) and the target individual (family member). Second, the anatomical structures of the extrathoracic airways and thoracic airways (exclusive of the lungs themselves) have been included in the entire revised ORNL phantom series of pediatric individuals. Values of cross-region photon dose are explored for use in radioactive aerosol inhalation exposures to members of the general public, and comparisons are made to values given by the ICRP in which surrogate organ assignments were made in the absence of explicit models of these airways. Finally, the revised ORNL phantoms of the adult male and adult female are used to determine internal photon exposures to

  18. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  19. Gamma radiation measurements in Brazilian commercial granites

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, R.M.; Veiga, R.; Mosquera, B.; Carvalho, C.; Macario, K. [Universidade Federal Fluminense, Niteroi (Brazil)

    2006-07-01

    Full text of publication follows: Gamma radiation from radionuclides which are characterized by half lives comparable to the age of the earth, such as 40 K and the radionuclides from the 238 U and 232 Th series, and their decay products, represent the main terrestrial source of irradiation to the human body. Their concentrations vary for different types of rocks, where high radiation levels are associated with igneous rocks such as granite. Thorium, uranium and potassium concentrations of granitic rocks are intimately related to their mineral compositions and general petrologic features. Then, these features associated with effects of weathering and metamorphism produce expressive alterations in the relationship between the natural radionuclides (Th, U, K, Th/U and Th/K). Consequently, the measurements of thorium, uranium, and potassium concentrations of different granite samples result on individual differentiation sequences. From the 232 Th, 238 U and 40 K activity concentrations obtained for each sample, it is possible to evaluate their respective dose rates in air, when these stones are used as tiling rocks. These results are of great interest in the environmental radiological protection study, since granites are widely used as building and ornamental materials, including as indoor covering. In this way, the Laboratory of Radioecology (L.A.R.A.) of the Physics Institute of the Universidade Federal Fluminense (I.F. -U.F.F.) has been performing analyzes on more than one hundred differ ent types of the main Brazilian commercial granites in last two years [1]. Using NaI and HP Ge gamma-ray spectrometers to determine the concentration of natural radionuclides in these samples, the annual effective dose rates and the gamma activity concentration index have been evaluated and compared to the limits proposed by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) and European Commission (E.C.). In addition, the correlations between thorium

  20. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2018-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  1. Broadband spectroscopy with external cavity quantum cascade lasers beyond conventional absorption measurements.

    Science.gov (United States)

    Lambrecht, Armin; Pfeifer, Marcel; Konz, Werner; Herbst, Johannes; Axtmann, Felix

    2014-05-07

    Laser spectroscopy is a powerful tool for analyzing small molecules, i.e. in the gas phase. In the mid-infrared spectral region quantum cascade lasers (QCLs) have been established as the most frequently used laser radiation source. Spectroscopy of larger molecules in the gas phase, of complex mixtures, and analysis in the liquid phase requires a broader tuning range and is thus still the domain of Fourier transform infrared (FTIR) spectroscopy. However, the development of tunable external cavity (EC) QCLs is starting to change this situation. The main advantage of QCLs is their high spectral emission power that is enhanced by a factor of 10(4) compared with thermal light sources. Obviously, transmission measurements with EC-QCLs in strongly absorbing samples are feasible, which can hardly be measured by FTIR due to detector noise limitations. We show that the high power of EC-QCLs facilitates spectroscopy beyond simple absorption measurements. Starting from QCL experiments with liquid samples, we show results of fiber evanescent field analysis (FEFA) to detect pesticides in drinking water. FEFA is a special case of attenuated total reflection spectroscopy. Furthermore, powerful CW EC-QCLs enable fast vibrational circular dichroism (VCD) spectroscopy of chiral molecules in the liquid phase - a technique which is very time consuming with standard FTIR equipment. We present results obtained for the chiral compound 1,1'-bi-2-naphthol (BINOL). Finally, powerful CW EC-QCLs enable the application of laser photothermal emission spectroscopy (LPTES). We demonstrate this for a narrowband and broadband absorber in the gas phase. All three techniques have great potential for MIR process analytical applications.

  2. Space life sciences: radiation risk assessment and radiation measurements in low Earth orbit.

    Science.gov (United States)

    2004-01-01

    The volume contains papers presented at COSPAR symposia in October 2002 about radiation risk assessment and radiation measurements in low Earth orbit. The risk assessment symposium brought together multidisciplinary expertise including physicists, biologists, and theoretical modelers. Topics included current knowledge about known and predicted radiation environments, radiation shielding, physics cross section models, improved ion beam transport codes, biological demonstrations of specific shielding materials and applications to a manned mission to Mars, advancements in biological measurement of radiation-induced protein expression profiles, and integration of physical and biological parameters to assess key elements of radiation risk. Papers from the radiation measurements in low Earth orbit symposium included data about dose, linear energy transfer spectra, and charge spectra from recent measurements on the International Space Station (ISS), comparison between calculations and measurements of dose distribution inside a human phantom and the neutron component inside the ISS; and reviews of trapped antiprotons and positrons inside the Earth's magnetosphere.

  3. Gene expression analysis in rice plants after external radiation exposure in Iitate village

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, G.; Fukumoto, M. [Institute of Development, Aging and Cancer, Tohoku University (Japan); Imanaka, T. [Research Reactor Institute, Kyoto University (Japan); Shibato, J. [Department of Anatomy I, School of Medicine, Showa University (Japan); Kubo, A. [Center for Environmental Biology and Ecosystem Studies, National Institute for Environmental Studies (Japan); Kikuchi, S. [Plant Genome Research Unit, Agrogenomics Research Center, National Institute of Agrobiological Sciences (Japan); Rakwal, R. [Organization for Educational Initiatives, University of Tsukuba (Japan)

    2014-07-01

    Rice plants exposed to radiation respond to the stress by activating self-defense mechanisms. A well-established molecular approach to measure stress is by cataloging global gene expression profiles. Here, we examined the effect of radiation exposure in a cereal crop model plant - rice (Oryza sativa L.) cultivar Nipponbare - in the village of Iitate of Fukushima prefecture. Iitate village is a highly radio-contaminated site due to the Fukushima Daiichi nuclear power plant accident following the Great East Japan Earthquake. The experimental approach comprised of five steps. First, healthy rice seedlings were grown in the greenhouse facility at National Institute for Environmental Sciences. Post-germination at 30 deg. C similarly germinated seeds were placed in neat rows in seedling pots having commercial soil (JA Zen-Noh, Japan; http//www.zennoh.or.jp/) with recommended NPK (nitrogen, phosphorus, and potash) doses at a controlled (25 deg. C, 70% relative humidity and natural light condition) greenhouse. Second, the seedlings were transported from a controlled greenhouse in Tsukuba to Iitate Farm (ITF) and placed, with no direct contact with soil, in a low-level gamma field where the rate of Cs-137 was 700 kBq/m{sup 2}. Third, exposure periods were set at 6, 12, 24, 48, and 72 h after arrival at ITF, and rice leaves at the 3. position (from the base) from 6 to 10 seedlings were sampled in dry ice. As control, rice leaves were sampled at the start in Tsukuba and immediately at arrival upon ITF; to know the radiation levels during growth and transport of the rice to ITF, accumulated radiation dose was calculated using a MYDOSE mini electronic pocket dosimeter (model PDM-222-52, ALOKA, Japan). A sample set was also taken at 72 h from healthy rice seedlings in the greenhouse at Tsukuba. All samples were stored at -80 deg. C. Accumulated total dose for exposed rice seedlings at 72 h was 200 mSv. Fourth, gene expression analysis was initiated by grinding the leaves to a

  4. DETERMINATION OF SUPERFICIAL ABSORBED DOSE FROM EXTERNAL EXPOSURE OF WEAKLY PENETRATING RADIATIONS

    Institute of Scientific and Technical Information of China (English)

    陈丽姝

    1994-01-01

    The methods of determining the superficial absorbed dose distributions in a water phantom by means of the experiments and available theories have been reported.The distributions of beta dose were measured by an extrapolation ionization chamber at definite depthes corresponding to some superficial organs and tissues such as the radiosensitive layer of the skin,cornea,sclera,anterior chamber and lens of eyeball.The ratios among superficial absorbed dose D(0.07) and average absorbed doses at the depthes 1,2,3,4,5 and 6mm are also obtained with Cross's methods.They can be used for confining the deterministic effects of some superficial tissues and organs such as the skin and the components of eyeball for weakly penetrating radiations.

  5. An integrative review of skin assessment tools used to evaluate skin injury related to external beam radiation therapy.

    Science.gov (United States)

    Baines, Carol R; McGuiness, William; O'Rourke, Geraldine A

    2017-04-01

    To review literature associated with external beam radiotherapy and skin damage. A focus of the literature search is to highlight and discuss the myriad of skin assessment tools that are available to the clinician when assessing skin injury in patients receiving external beam radiation therapy. It is apparent that despite considerable work being progressed in the development of individualised skin assessment tools, uptake and use is poor. These tools are designed to assist the clinician in the evaluation of damaged skin and predict the radiation wound development pathway. An integrated review can be used to address a mature or new and emerging topic through a systematic methodology, which is either theoretical or empirical, gained from research, practice or policy initiatives (Whittemore & Knafl, Journal of Advanced Nursing, 52, 2005, 546). This review is particularly concerned with the employment of skin assessment tools by clinicians in patients with radiation damaged skin. Using the search terms synonyms for radiation, skin and epidermal damage, PubMed/MEDLINE, Medical Complete and Web of Science databases were searched. Consulting professional peers was employed as part of the inclusion and exclusion process. There is a high level of unpredictability about which patient will have an uncomplicated course of external beam radiotherapy. Variables may include, but are not limited to, an acute reaction, a delayed reaction resulting in actual skin damage or no visible skin disturbance. The skin assessment tools that are readily available are not regularly referenced in clinical practice when attempting to manage the many side effects of radiation therapy. Skin assessment tools require ongoing clinical validation, so they can be used to guide practitioners to undertake further assessment of skin integrity. The current body of knowledge suggests clinicians caring for patients receiving therapeutic radiotherapy should consider integrating a recognised patient assessment

  6. Calibrating a custom-made densitometer for radiation hardness measurements

    CERN Document Server

    Vaananen, Mika Petteri

    2017-01-01

    A custom-made densitometer was set up to be used in radiation hardness measurements of scintillating fibres. Also, a measurement setup to measure the minimal bending radius of scintillating fibres was designed and implemented.

  7. Study of external exposure doses received by Cuban population due to terrestrial component of the environmental radiation sources; Estudio de las dosis por exposicion externa que recibe la poblacion cubana debidas a la componente terrestre de la radiacion ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Zerquera, Juan Tomas; Prendes Alonso, Miguel [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba); Brigido Flores, Osvaldo [Laboratorio de Vigilancia Radiologica Ambiental de Camaguey (Cuba); Hernandez Perez, Alberto [Laboratorio de Vigilancia Radiologica Ambiental de Oriente, Holguin (Cuba)

    2001-07-01

    The work presents the results of the study carried out to evaluate the doses that the Cuban population receives for the external exposition to the terrestrial component of the environmental sources of radiation. Starting from the carried out measurements it was possible to estimate the doses effective representative annual stockings that the Cuban population receives for external exposition to the terrestrial radiation, considering the permanency in indoors and outdoors. The dose received due to this component was 180{+-}14 mSv/year. These values are in the range of those reported internationally. (author)

  8. External radiation and HDR-brachytherapy in the treatment of breast cancer. Externe Bestrahlung und interstitielle HDR-Brachytherapie in der Bestrahlung des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Track, C. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Seewald, D.H. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Zoidl, J.P. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Hammer, J. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria))

    1994-04-01

    In the breast conserving management of mammary cancer a high-dose-rate (HDR)-Iridium-192 source is used for interstitial boosting of the primary tumor site after external radiotherapy. We want to show the clinical results and side effects and to demonstrate the safe use of a HDR source. From December 1984 until November 1988, 154 patients with breast cancer stage T1-2, N0-1 were treated by conservative surgery and radiation. A dose of 45 to 50 Gy was given to the whole breast by external radiotherapy, and the previous tumor area was boosted by an interstitial implant with Iridium-192 HDR. We applied 10 Gy in one or two fractions. The mean follow-up period of survivors is 76 months (range 57 to 107 months). In 36 patients failures occured: eight patients (5%) developed local recurrences, 31 patients (20%) had distant metastases, and 19 (12%) died with cancer. The Kaplan-Meier estimation for five year overall survival is 86.9%, for disease-specific survival 89.3%, for local control 95.8%, and for disease free survival 80.1%. The most frequent late effects were telangiectasia (11%), fibrotic masses in the previous tumor area (6.5%), and lymphedema of the arm (6.5%). No serious complications could be observed. (orig./MG)

  9. Normal tissue tolerance to external beam radiation therapy: Thyroid; Dose de tolerance des tissus sains: la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Berges, O.; Giraud, P. [Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, universite Paris Descartes, 75 - Paris (France); Belkacemi, Y. [Service d' oncologie-radiotherapie, CHU Henri-Mondor, universite Paris 12, 94 - Creteil (France)

    2010-07-15

    The thyroid is the most developed endocrine gland of the body. Due to its anatomical location, it may be exposed to ionizing radiation in external radiotherapy involving head and neck. This review aims to describe the thyroid radiation disorders, probably under-reported in the literature, their risk factors and follow-up procedures. The functional changes after external beam radiation consists mainly of late effects occurring beyond 6 months, and are represented by the clinical and subclinical hypothyroidism. Its incidence is approximately 20 to 30% and it can occur after more than 25 years after radiation exposure. Hyperthyroidism and auto-immune manifestations have been described in a lesser proportion. The morphological changes consist of benign lesions, primarily adenomas, and malignant lesions, the most feared and which incidence is 0.35%. The onset of hypothyroidism depends of the total dose delivered to the gland, and the irradiated. Modern techniques of conformal radiotherapy with modulated intensity could improve the preservation of the thyroid, at the expense of the increase in low doses and the theoretical risk of secondary cancers. (authors)

  10. Radiation detection and measurement student solutions manual

    CERN Document Server

    Wehe, David K

    2012-01-01

    This is the resource that engineers turn to in the study of radiation detection. The fourth edition takes into account the technical developments that continue to enhance the instruments and techniques available for the detection and spectroscopy of ionizing radiation. New coverage is presented on ROC curves, micropattern gas detectors, new sensors for scintillation light, and the excess noise factor. Revised discussions are also included on TLDs and cryogenic spectrometers, radiation backgrounds, and the VME standard. Engineers will gain a strong understanding of the field with this updated book.

  11. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  12. Measurement and properties of dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko Tapio; Partanen, Mari; Ojala, Jarkko; Sipilae, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-03-22

    In small-beam radiation therapy (RT) the measurement of beam quality parameter i.e. tissue-phantom ratio or TPR20,10 with conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of possible beam quality parameter in small beams was studied, namely the dose-area product ratio or DAPR20,10. With this method, the measurement of a dose-area product (DAP) with a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging present with the use of a point detector. In this study, properties of DAPR20,10 of cone-collimated 6 MV photon beam were investigated with Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained by two LAC detectors PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP with EBT3 film and Razor diode detector was studied. The determination of DAPR20,10 value was found to be feasible in external small-beam radiotherapy of cone-collimated beams with diameters from 4 to 40 mm with the two LACs, MC calculation and Razor diode. Measurements indicated a constant DAPR20,10 value for fields from 20 to 40 mm in diameter with maximum relative change of 0.6%, but an increase of 7.0% for fields from 20 to 4 mm in diameter for PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for studied cone-collimated 6 MV photon beams from 4 to 40 mm in diameter. This has a consequence that with reported DAPR20,10 value there should be a reference to the size of the used LAC active area or the DAP integration area.

  13. About Solar Radiation Intensity Measurements and Data Processing

    Directory of Open Access Journals (Sweden)

    MICH-VANCEA Claudiu

    2012-10-01

    Full Text Available Measuring the intensity of solar radiation is one of the directions of investigation necessary for the implementation of photovoltaic systems in a particular geographical area. This can be done by using specific measuring equipment (pyranometer sensors based onthermal or photovoltaic principle. In this paper it is presented a method for measuring solar radiation (which has two main components - direct radiation and diffuse radiation with sensors based on photovoltaic principle. Such data are processed for positioning solarpanels, in order their efficiency to be maximized.

  14. Solid cancer mortality associated with chronic external radiation exposure at the French atomic energy commission and nuclear fuel company.

    Science.gov (United States)

    Metz-Flamant, C; Samson, E; Caër-Lorho, S; Acker, A; Laurier, D

    2011-07-01

    Studies of nuclear workers make it possible to directly quantify the risks associated with ionizing radiation exposure at low doses and low dose rates. Studies of the CEA (Commissariat à l'Energie Atomique) and AREVA Nuclear Cycle (AREVA NC) cohort, currently the most informative such group in France, describe the long-term risk to nuclear workers associated with external exposure. Our aim is to assess the risk of mortality from solid cancers among CEA and AREVA NC nuclear workers and its association with external radiation exposure. Standardized mortality ratios (SMRs) were calculated and internal Poisson regressions were conducted, controlling for the main confounding factors [sex, attained age, calendar period, company and socioeconomic status (SES)]. During the period 1968-2004, there were 2,035 solid cancers among the 36,769 CEA-AREVA NC workers. Cumulative external radiation exposure was assessed for the period 1950-2004, and the mean cumulative dose was 12.1 mSv. Mortality rates for all causes and all solid cancers were both significantly lower in this cohort than in the general population. A significant excess of deaths from pleural cancer, not associated with cumulative external dose, was observed, probably due to past asbestos exposure. We observed a significant excess of melanoma, also unassociated with dose. Although cumulative external dose was not associated with mortality from all solid cancers, the central estimated excess relative risk (ERR) per Sv of 0.46 for solid cancer mortality was higher than the 0.26 calculated for male Hiroshima and Nagasaki A-bomb survivors 50 years or older and exposed at the age of 30 years or older. The modification of our results after stratification for SES demonstrates the importance of this characteristic in occupational studies, because it makes it possible to take class-based lifestyle differences into account, at least partly. These results show the great potential of a further joint international study of

  15. Particle fluence measurements by activation technique for radiation damage studies

    CERN Document Server

    León-Florián, E; Furetta, C; Leroy, Claude

    1995-01-01

    High-level radiation environment can produce radiation damage in detectors and their associate electronic components. The establishment of a correlation between damage, irradiation level and absorbed dose requires a precise measurement of the fluence of particles causing the damage. The activation technique is frequently used for performing particle fluence measurements. A review of this technique is presented.

  16. Influence of an external axial magnetic field on betatron radiation from the interaction of a circularly polarized laser with plasma

    Science.gov (United States)

    Du, Bao; Wang, Xiao-Fang

    2017-09-01

    In this paper, theoretical analyses and numerical calculations are carried out to investigate the influence of an externally applied axial constant magnetic field on electrons' betatron radiation when an ultra-short, circularly polarized laser pulse of a peak intensity I0 = 5 × 1019 W/cm2 propagates in plasma of an electron density n0 = 1020/cm3. Ring-like x-ray radiation is emitted from the electrons' betatron oscillations. The applied magnetic field can modulate the resonance process between an electron's betatron oscillation and the laser electric field, and the electron energy gain from the direct laser acceleration is thus changed. When a magnetic field of strength B0=3 × 103 T is applied, which is in anti-parallel to the self-generated axial magnetic field, both the trapping efficiency of electrons by the wakefield and the maximum accelerated energy are increased. The maximum electron energy, the peak of angular radiation, and the total radiation energy are increased by 11.0%, 45.6%, and 41.1%, respectively, and the radiation spectra are blue-shifted significantly.

  17. Organ dose conversion coefficients for pediatric reference computational phantoms in external photon radiation fields

    Science.gov (United States)

    Chang, Lienard A.

    In the event of a radiological accident or attack, it is important to estimate the organ doses to those exposed. In general, it is difficult to measure organ dose directly in the field and therefore dose conversion coefficients (DCC) are needed to convert measurable values such as air kerma to organ dose. Previous work on these coefficients has been conducted mainly for adults with a focus on radiation protection workers. Hence, there is a large gap in the literature for pediatric values. This study coupled a Monte Carlo N-Particle eXtended (MCNPX) code with International Council of Radiological Protection (ICRP)-adopted University of Florida and National Cancer Institute pediatric reference phantoms to calculate a comprehensive list of dose conversion coefficients (mGy/mGy) to convert air-kerma to organ dose. Parameters included ten phantoms (newborn, 1-year, 5-year, 10-year, 15-year old male and female), 28 organs over 33 energies between 0.01 and 20 MeV in six (6) irradiation geometries relevant to a child who might be exposed to a radiological release: anterior-posterior (AP), posterior-anterior (PA), right-lateral (RLAT), left-lateral (LLAT), rotational (ROT), and isotropic (ISO). Dose conversion coefficients to the red bone marrow over 36 skeletal sites were also calculated. It was hypothesized that the pediatric organ dose conversion coefficients would follow similar trends to the published adult values as dictated by human anatomy, but be of a higher magnitude. It was found that while the pediatric coefficients did yield similar patterns to that of the adult coefficients, depending on the organ and irradiation geometry, the pediatric values could be lower or higher than that of the adult coefficients.

  18. Abscess of the iliopsoas muscle associated external fistula of the rectum caused by radiation proctitis. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Shigeru; Imazu, Hiroki; Matubara, Toshiki; Sakurai, Yoichi; Ochiai, Masahiro; Funabiki, Takahiko [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine

    1999-12-01

    This paper deals with a case of abscess of the iliopsoas muscle, an intractable external fistula of the rectum caused by radiation proctitis in a 68-year-old man. There were previous histories of undergoing an A-C bypass operation for coronary stricture 10 years before; and undergoing aportial resection of the bladder with radiation therapy for urinary bladder cancer, followed by colostomy for hemorrhage and stricture of the rectum for radiation proctitis 2 years before admission. In April, 1997 when he had been treated at outpatient clinic, exhumation of pusfrom the sacurred that was diagnosed external fistula of the rectum on a fistulography and he was continuously treated on an ambulant basis. On November 17, 1997, the patient had a temperature 38.7deg C, the white blood cell count increased to 35 x 10{sup 4} /ml, inflammation reaction increased, and unconsciousness appeared. An emergency CT revealed retention of fluid in the retroperitoneum covering from the fistulation through the iliopsoas muscle to pelvis. An abscess of the iliopsoas muscle was diagnosed. It was determined that any operations under general anesthesia were impossible due to poor general condition, and an emergency incision drainage was performed under local anesthesia. Thereafter, the patient developed MRSA septicemia which demanded redrainage and strict general management, but he was successfully freed from the management. Although the intractable fistula in persistently present, he was discharged after a resection of sequestrum and is followed on an ambulant basis. (author)

  19. Novel Parameter Predicting Grade 2 Rectal Bleeding After Iodine-125 Prostate Brachytherapy Combined With External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Hanada, Takashi; Ohashi, Toshio [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Yorozu, Atsunori; Toya, Kazuhito [Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Saito, Shiro [Department of Urology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Shigematsu, Naoyuki [Department of Radiology, Keio University School of Medicine, Tokyo (Japan)

    2013-09-01

    Purpose: To propose a novel parameter predicting rectal bleeding on the basis of generalized equivalent uniform doses (gEUD) after {sup 125}I prostate brachytherapy combined with external beam radiation therapy and to assess the predictive value of this parameter. Methods and Materials: To account for differences among radiation treatment modalities and fractionation schedules, rectal dose–volume histograms (DVHs) of 369 patients with localized prostate cancer undergoing combined therapy retrieved from corresponding treatment planning systems were converted to equivalent dose-based DVHs. The gEUDs for the rectum were calculated from these converted DVHs. The total gEUD (gEUD{sub sum}) was determined by a summation of the brachytherapy and external-beam radiation therapy components. Results: Thirty-eight patients (10.3%) developed grade 2+ rectal bleeding. The grade 2+ rectal bleeding rate increased as the gEUD{sub sum} increased: 2.0% (2 of 102 patients) for <70 Gy, 10.3% (15 of 145 patients) for 70-80 Gy, 15.8% (12 of 76 patients) for 80-90 Gy, and 19.6% (9 of 46 patients) for >90 Gy (P=.002). Multivariate analysis identified age (P=.024) and gEUD{sub sum} (P=.000) as risk factors for grade 2+ rectal bleeding. Conclusions: Our results demonstrate gEUD to be a potential predictive factor for grade 2+ late rectal bleeding after combined therapy for prostate cancer.

  20. Measurement and modelling of neon radiation profiles in radiating boundary discharges in ASDEX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Dux, R.; Kallenbach, A.; Bessenrodt-Weberpals, M.; Behringer, K.; Bosch, H.S.; Fuchs, J.C.; Gehre, O.; Mast, F.; Poschenrieder, W.; Murmann, H.; Salzmann, H.; Schweinzer, J.; Suttrop, W. [MPI fuer Plasmaphysik, EURATOM Association, Garching and Berlin (Germany); ASDEX Upgrade- and NI-Team

    1996-02-01

    The radiation and transport characteristics of ASDEX Upgrade discharges with a neon driven radiative mantle are modelled using a 1-D radial impurity transport code that has been coupled to a simple divertor model describing particle recycling and pumping. The code is well suited to describe the measured impurity line radiation, total, soft X-ray and bremsstrahlung radiation in regions of the plasma which are not dominated by two dimensional effects. The recycling and pumping behaviour of neon as well as the bulk transport of neon for radiative boundary scenarios are discussed. (orig.)

  1. Natural gas pyrolysis in double-walled reactor tubes using thermal plasma or concentrated solar radiation as external heating source

    Institute of Scientific and Technical Information of China (English)

    Stèphane Abanades; Stefania Tescari; Sylvain Rodat; Gilles Flamant

    2009-01-01

    The thermal pyrolysis of natural gas as a clean hydrogen production route is examined.The concept of a double-walled reactor tube is proposed and implemented.Preliminary experiments using an external plasma heating source are carded out to validate this concept.The results point out the efficient CH4 dissociation above 1850 K (CH4 conversion over 90%) and the key influence of the gas residence time.Simulations are performed to predict the conversion rate of CH4 at the reactor outlet,and are consistent with experimental tendencies.A solar reactor prototype featuring four independent double-walled tubes is then developed.The heat in high temperature process required for the endothermic reaction of natural gas pyrolysis is supplied by concentrated solar energy.The tubes are heated uniformly by radiation using the blackbody effect of a cavity-receiver absorbing the concentrated solar irradiation through a quartz window.The gas composition at the reactor outlet,the chemical conversion of CH4,and the yield to H2 are determined with respect to reaction temperature,inlet gas flow-rates,and feed gas composition.The longer the gas residence time,the higher the CH4 conversion and H2 yield,whereas the lower the amount of acetylene.A CH4 conversion of 99% and H2 yield of about 85% are measured at 1880 K with 30% CH4 in the feed gas (6 L/min injected and residence time of 18 ms).A temperature increase from 1870 K to 1970 K does not improve the H2 yield.

  2. Benefit of Adjuvant Brachytherapy Versus External Beam Radiation for Early Breast Cancer: Impact of Patient Stratification on Breast Preservation

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Grace L. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jiang, Jing [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Xu, Ying [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hoffman, Karen E. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hunt, Kelly K. [Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D., E-mail: bsmith3@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-02-01

    Purpose: Brachytherapy after lumpectomy is an increasingly popular breast cancer treatment, but data concerning its effectiveness are conflicting. Recently proposed “suitability” criteria guiding patient selection for brachytherapy have never been empirically validated. Methods: Using the Surveillance, Epidemiology, and End Results–Medicare linked database, we compared women aged 66 years or older with invasive breast cancer (n=28,718) or ductal carcinoma in situ (n=7229) diagnosed from 2002 to 2007, treated with lumpectomy alone, brachytherapy, or external beam radiation therapy (EBRT). The likelihood of breast preservation, measured by subsequent mastectomy risk, was compared by use of multivariate proportional hazards, further stratified by American Society for Radiation Oncology (ASTRO) brachytherapy suitability groups. We compared 1-year postoperative complications using the χ{sup 2} test and 5-year local toxicities using the log-rank test. Results: For patients with invasive cancer, the 5-year subsequent mastectomy risk was 4.7% after lumpectomy alone (95% confidence interval [CI], 4.1%-5.4%), 2.8% after brachytherapy (95% CI, 1.8%-4.3%), and 1.3% after EBRT (95% CI, 1.1%-1.5%) (P<.001). Compared with lumpectomy alone, brachytherapy achieved a more modest reduction in adjusted risk (hazard ratio [HR], 0.61; 95% CI, 0.40-0.94) than achieved with EBRT (HR, 0.22; 95% CI, 0.18-0.28). Relative risks did not differ when stratified by ASTRO suitability group (P=.84 for interaction), although ASTRO “suitable” patients did show a low absolute subsequent mastectomy risk, with a minimal absolute difference in risk after brachytherapy (1.6%; 95% CI, 0.7%-3.5%) versus EBRT (0.8%; 95% CI, 0.6%-1.1%). For patients with ductal carcinoma in situ, EBRT maintained a reduced risk of subsequent mastectomy (HR, 0.40; 95% CI, 0.28-0.55; P<.001), whereas the small number of patients treated with brachytherapy (n=179) precluded definitive comparison with lumpectomy alone

  3. Telomere Length in Aged Mayak PA Nuclear Workers Chronically Exposed to Internal Alpha and External Gamma Radiation.

    Science.gov (United States)

    Scherthan, Harry; Sotnik, Natalia; Peper, Michel; Schrock, Gerrit; Azizova, Tamara; Abend, Michael

    2016-06-01

    Telomeres consist of GC-rich DNA repeats and the "shelterin" protein complex that together protect chromosome ends from fusion and degradation. Telomeres shorten with age due to incomplete end replication and upon exposure to environmental and intrinsic stressors. Exposure to ionizing radiation is known to modulate telomere length. However, the response of telomere length in humans chronically exposed to radiation is poorly understood. Here, we studied relative telomere length (RTL) by IQ-FISH to leukocyte nuclei in a group of 100 workers from the plutonium production facility at the Mayak Production Association (PA) who were chronically exposed to alpha-emitting ((239)Pu) radiation and/or gamma (photon) radiation, and 51 local residents serving as controls, with a similar mean age of about 80 years. We applied generalized linear statistical models adjusted for age at biosampling and the second exposure type on a linear scale and observed an age-dependent telomere length reduction. In those individuals with the lowest exposure, a significant reduction of about 20% RTL was observed, both for external gamma radiation (≤1 Gy) and internal alpha radiation (≤0.05-0.1 Gy to the red bone marrow). In highly exposed individuals (>0.1 Gy alpha, 1-1.5 Gy gamma), the RTL was similar to control. Stratification by gender revealed a significant (∼30%) telomere reduction in low-dose-exposed males, which was absent in females. While the gender differences in RTL may reflect different working conditions, lifestyle and/or telomere biology, absence of a dose response in the highly exposed individuals may reflect selection against cells with short telomeres or induction of telomere-protective effects. Our observations suggest that chronic systemic exposure to radiation leads to variable dose-dependent effects on telomere length.

  4. Effective UV radiation from model calculations and measurements

    Science.gov (United States)

    Feister, Uwe; Grewe, Rolf

    1994-01-01

    Model calculations have been made to simulate the effect of atmospheric ozone and geographical as well as meteorological parameters on solar UV radiation reaching the ground. Total ozone values as measured by Dobson spectrophotometer and Brewer spectrometer as well as turbidity were used as input to the model calculation. The performance of the model was tested by spectroradiometric measurements of solar global UV radiation at Potsdam. There are small differences that can be explained by the uncertainty of the measurements, by the uncertainty of input data to the model and by the uncertainty of the radiative transfer algorithms of the model itself. Some effects of solar radiation to the biosphere and to air chemistry are discussed. Model calculations and spectroradiometric measurements can be used to study variations of the effective radiation in space in space time. The comparability of action spectra and their uncertainties are also addressed.

  5. An overview of current practice in external beam radiation oncology with consideration to potential benefits and challenges for nanotechnology.

    Science.gov (United States)

    King, Raymond B; McMahon, Stephen J; Hyland, Wendy B; Jain, Suneil; Butterworth, Karl T; Prise, Kevin M; Hounsell, Alan R; McGarry, Conor K

    2017-01-01

    Over the past two decades, there has been a significant evolution in the technologies and techniques employed within the radiation oncology environment. Over the same period, extensive research into the use of nanotechnology in medicine has highlighted a range of potential benefits to its incorporation into clinical radiation oncology. This short communication describes key tools and techniques that have recently been introduced into specific stages of a patient's radiotherapy pathway, including diagnosis, external beam treatment and subsequent follow-up. At each pathway stage, consideration is given towards how nanotechnology may be combined with clinical developments to further enhance their benefit, with some potential opportunities for future research also highlighted. Prospective challenges that may influence the introduction of nanotechnology into clinical radiotherapy are also discussed, indicating the need for close collaboration between academic and clinical staff to realise the full clinical benefit of this exciting technology.

  6. Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Dean J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection; Thoreson, Gregory G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection; Horne, Steven M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection

    2014-01-01

    Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex, scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

  7. Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Dean J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection; Thoreson, Gregory G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection; Horne, Steven M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection

    2014-01-01

    Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

  8. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    Science.gov (United States)

    Lubis, L. E.; Badawy, M. K.

    2016-03-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care.

  9. Mode-locking external-cavity laser-diode sensor for displacement measurements of technical surfaces

    Science.gov (United States)

    Czarske, Jürgen; Möbius, Jasper; Moldenhauer, Karsten

    2005-09-01

    A novel laser sensor for position measurements of technical solid-state surfaces is proposed. An external Fabry-Perot laser cavity is assembled by use of an antireflection-coated laser diode together with the technical surface. Mode locking results from pumping the laser diode synchronously to the mode spacing of the cavity. The laser cavity length, i.e., the distance to the measurement object, is determined by evaluation of the modulation transfer function of the cavity by means of a phase-locked loop. The mode-locking external-cavity laser sensor incorporates a resonance effect that results in highly resolving position and displacement measurements. More than a factor-of-10 higher resolution than with conventional nonresonant sensing principles is achieved. Results of the displacement measurements of various technical surfaces are reported. Experimental and theoretical investigations are in good agreement.

  10. Radiation Measurements in Simulated Ablation Layers

    Science.gov (United States)

    2010-12-06

    effect in the presence of radiation, at speeds of 8 km/sec and over. The „ nitridation ‟ reaction is also important (Park 2006), where nitrogen atoms...conditions. Due to the long test time of this facility, and the cleanliness of the flow which avoids the surface damage caused in the expansion tubes...particulate components of the surface is very important, and full protection of exposed surfaces from oxidation has not yet been achieved. The nitridation

  11. Radiative corrections in nucleon time-like form factors measurements

    Energy Technology Data Exchange (ETDEWEB)

    Van de Wiele, Jacques [Universite de Paris-Sud, Institut de Physique Nucleaire, Orsay Cedex (France); Ong, Saro [Universite de Paris-Sud, Institut de Physique Nucleaire, Orsay Cedex (France); Universite de Picardie Jules Verne, Amiens (France)

    2013-02-15

    The completely general radiative corrections to lowest order, including the final- and initial-state radiations, are studied in proton-antiproton annihilation into an electron-positron pair. Numerical estimates have been made in a realistic configuration of the PANDA detector at FAIR for the proton time-like form factors measurements. (orig.)

  12. Traceability of radiation measurements: musings of a user

    Energy Technology Data Exchange (ETDEWEB)

    Kathren, R.L.

    1980-04-01

    Although users of radiation desire measurement traceability for a number of reasons, including legal, regulatory, contractual, and quality assurance requirements, there exists no real definition of the term in the technical literature. Definitions are proposed for both traceability and traceability to the National Bureau of Standards. The hierarchy of radiation standards is discussed and allowable uncertainties are given for each level. Areas of need with respect to radiation standards are identified, and a system of secondary radiation calibration laboratories is proposed as a means of providing quality calibrations and traceability on a routine basis.

  13. Traceability of radiation measurements: musings of a user

    Energy Technology Data Exchange (ETDEWEB)

    Kathren, R.L.

    1980-04-01

    Although users of radiation desire measurement traceability for a number of reasons, including legal, regulatory, contractual, and quality assurance requirements, there exists no real definition of the term in the technical literature. Definitions are proposed for both traceability and traceability to the National Bureau of Standards. The hierarchy of radiation standards is discussed and allowable uncertainties are given for each level. Areas of need with respect to radiation standards are identified, and a system of secondary radiation calibration laboratories is proposed as a means of providing quality calibrations and traceability on a routine basis.

  14. Measurement of absorbed dose and proposed radiation exposure level

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takayuki; Koizumi, Masayuki; Furukawa, Tomo [Tokai Univ., Isehara, Kanagawa (Japan). Hospital

    2003-03-01

    Absorbed dose was measured in clinical X-ray examinations using thermoluminescence dosimeter (TLD). Moreover, we distributed the levels of radiation exposure into 3 classes. The presumed dose of the internal organs, e.g., uterus dose, was computed to depth doses with a surface dose. This information provides a prediction of the influence of radiation, and the examination can be performed with the informed consent of the patient. Moreover, we examined the distribution of the level of absorbed dose. We proposed two kinds of radiation exposure level, one to the fetus in a pregnant woman and a general level of radiation exposure that is not applied to pregnant women. The levels were as follows: 0.5 mGy and 100 mGy were considered the boundaries for fetal radiation exposure in a pregnant woman, and 200 mGy and 3 Gy were considered the boundaries for the general level of radiation exposure (excluding pregnant women). (author)

  15. Leukemia risk associated with chronic external exposure to ionizing radiation in a French cohort of nuclear workers.

    Science.gov (United States)

    Metz-Flamant, C; Samson, E; Caër-Lorho, S; Acker, A; Laurier, D

    2012-11-01

    Leukemia is one of the earliest cancer effects observed after acute exposure to relatively high doses of ionizing radiation. Leukemia mortality after external exposure at low doses and low-dose rates has been investigated at the French Atomic Energy Commission (CEA) and Nuclear Fuel Company (AREVA NC) after an additional follow-up of 10 years. The cohort included radiation-monitored workers employed for at least one year during 1950-1994 at CEA or AREVA NC and followed during 1968-2004. Association between external exposure and leukemia mortality was estimated with excess relative risk (ERR) models and time-dependent modifying factors were investigated with time windows. The cohort included 36,769 workers, followed for an average of 28 years, among whom 73 leukemia deaths occurred. Among the workers with a positive recorded dose, the mean cumulative external dose was 21.7 mSv. Results under a 2-year lag assumption suggested that the risk of leukemia (except chronic lymphatic leukemia) increased significantly by 8% per 10 mSv. The magnitude of the association for myeloid leukemia was larger. The higher ERR/Sv for doses received 2-14 years earlier suggest that time since exposure modifies the effect. The ERR/Sv also appeared higher for doses received at exposure rates ≥20 mSv per year. These results are consistent with those found in other studies of nuclear workers. However, confidence intervals are still wide. Further analyses should be conducted in pooled cohorts of nuclear workers.

  16. External beam irradiation in the palliation of bone metastases: a practice analysis among Sicilian Departments of Radiation Oncology.

    Science.gov (United States)

    Pergolizzi, Stefano; Pontoriero, Antonio; Delia, Pietro; Santacaterina, Anna

    2004-01-01

    In the treatment of bone metastases, the choice of radiation fractionation, total radiation dose, delivery technique, and imaging studies before treatment varies among radiation oncologists. Surveys on this issue, using case scenarios, have been published by groups from Europe, North America, and Australia-New Zealand. Our objective was to analyze retrospectively the "real" practice in nine radiotherapy centers located in Sicily. A questionnaire including 17 items was distributed to 30 practicing radiation oncologists working in seven departments of four Sicilian cities (Messina, Catania, Ragusa and Palermo) during a meeting of the Sicilian Division of the Associazione Italiana Radioterapia Oncologica (AIRO). Participants were asked to answer the questions using a card for every patient treated with external beam irradiation from 1 January to 31 December, 2000. Six centers returned the questionnaires; 332 cards were valuable for a total of 5644 responses. All six responding departments used linear accelerators for treatment delivery. The most common dose fractionation was 30 Gy in 10 fractions and the most common technique used was opposed parallel local fields. Before the start of irradiation a bone scan was performed in 325 of the 332 (98%) patients treated and CT and/or MRI was performed in 320 (96%); surprisingly, standard roentgenograms were used in only 142 of 332 patients (42.8%). The "real" radiation practice for bone metastases in the region of Sicily confirms the results of the previously reported international surveys: there is a clear preference for fractionated treatment and local field therapy. The results of randomized studies, which demonstrated both the efficacy and the feasibility of a single 6-8 Gy fraction in the palliation of bone metastases, have little or no impact on the pattern of practice.

  17. Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Mingyao [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States); Bharat, Shyam [Philips Research North America, Briarcliff Manor, New York (United States); Michalski, Jeff M.; Gay, Hiram A. [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States); Hou, Wei-Hsien [St Louis University School of Medicine, St Louis, Missouri (United States); Parikh, Parag J., E-mail: pparikh@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States)

    2013-03-15

    Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

  18. Adaptive radiation therapy for postprostatectomy patients using real-time electromagnetic target motion tracking during external beam radiation therapy.

    Science.gov (United States)

    Zhu, Mingyao; Bharat, Shyam; Michalski, Jeff M; Gay, Hiram A; Hou, Wei-Hsien; Parikh, Parag J

    2013-03-15

    Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (Dmin) with the planned Dmin to the CTV. Treatments were considered adequate if the delivered CTV Dmin is at least 95% of the planned CTV Dmin. Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: -0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus -- the "D-shuttle" project --

    CERN Document Server

    Adachi, N; Adjovi, Y; Aida, K; Akamatsu, H; Akiyama, S; Akli, A; Ando, A; Andrault, T; Antonietti, H; Anzai, S; Arkoun, G; Avenoso, C; Ayrault, D; Banasiewicz, M; Banaśkiewicz, M; Bernandini, L; Bernard, E; Berthet, E; Blanchard, M; Boreyko, D; Boros, K; Charron, S; Cornette, P; Czerkas, K; Dameron, M; Date, I; De Pontbriand, M; Demangeau, F; Dobaczewski, Ł; Dobrzyński, L; Ducouret, A; Dziedzic, M; Ecalle, A; Edon, V; Endo, K; Endo, T; Endo, Y; Etryk, D; Fabiszewska, M; Fang, S; Fauchier, D; Felici, F; Fujiwara, Y; Gardais, C; Gaul, W; Guérin, L; Hakoda, R; Hamamatsu, I; Handa, K; Haneda, H; Hara, T; Hashimoto, M; Hashimoto, T; Hashimoto, K; Hata, D; Hattori, M; Hayano, R; Hayashi, R; Higasi, H; Hiruta, M; Honda, A; Horikawa, Y; Horiuchi, H; Hozumi, Y; Ide, M; Ihara, S; Ikoma, T; Inohara, Y; Itazu, M; Ito, A; Janvrin, J; Jout, I; Kanda, H; Kanemori, G; Kanno, M; Kanomata, N; Kato, T; Kato, S; Katsu, J; Kawasaki, Y; Kikuchi, K; Kilian, P; Kimura, N; Kiya, M; Klepuszewski, M; Kluchnikov, E; Kodama, Y; Kokubun, R; Konishi, F; Konno, A; Kontsevoy, V; Koori, A; Koutaka, A; Kowol, A; Koyama, Y; Kozioł, M; Kozue, M; Kravtchenko, O; Kruczała, W; Kudła, M; Kudo, H; Kumagai, R; Kurogome, K; Kurosu, A; Kuse, M; Lacombe, A; Lefaillet, E; Magara, M; Malinowska, J; Malinowski, M; Maroselli, V; Masui, Y; Matsukawa, K; Matsuya, K; Matusik, B; Maulny, M; Mazur, P; Miyake, C; Miyamoto, Y; Miyata, K; Miyata, K; Miyazaki, M; Molęda, M; Morioka, T; Morita, E; Muto, K; Nadamoto, H; Nadzikiewicz, M; Nagashima, K; Nakade, M; Nakayama, C; Nakazawa, H; Nihei, Y; Nikul, R; Niwa, S; Niwa, O; Nogi, M; Nomura, K; Ogata, D; Ohguchi, H; Ohno, J; Okabe, M; Okada, M; Okada, Y; Omi, N; Onodera, H; Onodera, K; Ooki, S; Oonishi, K; Oonuma, H; Ooshima, H; Oouchi, H; Orsucci, M; Paoli, M; Penaud, M; Perdrisot, C; Petit, M; Piskowski, A; Płocharski, A; Polis, A; Polti, L; Potsepnia, T; Przybylski, D; Pytel, M; Quillet, W; Remy, A; Robert, C; Sadowski, M; Saito, M; Sakuma, D; Sano, K; Sasaki, Y; Sato, N; Schneider, T; Schneider, C; Schwartzman, K; Selivanov, E; Sezaki, M; Shiroishi, K; Shustava, I; Śniecińska, A; Stalchenko, E; Staroń, A; Stromboni, M; Studzińska, W; Sugisaki, H; Sukegawa, T; Sumida, M; Suzuki, Y; Suzuki, K; Suzuki, R; Suzuki, H; Suzuki, K; Świderski, W; Szudejko, M; Szymaszek, M; Tada, J; Taguchi, H; Takahashi, K; Tanaka, D; Tanaka, G; Tanaka, S; Tanino, K; Tazbir, K; Tcesnokova, N; Tgawa, N; Toda, N; Tsuchiya, H; Tsukamoto, H; Tsushima, T; Tsutsumi, K; Umemura, H; Uno, M; Usui, A; Utsumi, H; Vaucelle, M; Wada, Y; Watanabe, K; Watanabe, S; Watase, K; Witkowski, M; Yamaki, T; Yamamoto, J; Yamamoto, T; Yamashita, M; Yanai, M; Yasuda, K; Yoshida, Y; Yoshida, A; Yoshimura, K; Żmijewska, M; Zuclarelli, E

    2015-01-01

    Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014. In total 216 high-school students and teachers participated in the study. Each participant wore an electronic personal dosimeter "D-shuttle" for two weeks, and kept a journal of his/her whereabouts and activities. The distributions of annual external doses estimated for each region overlap with each other, demonstrating that the personal external individual doses in locations where residence is currently allowed in Fukushima Prefecture and in Belarus are well within the range of estimated annual doses due to the background radiation level of other regions/countries.

  20. Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus-the 'D-shuttle' project.

    Science.gov (United States)

    Adachi, N; Adamovitch, V; Adjovi, Y; Aida, K; Akamatsu, H; Akiyama, S; Akli, A; Ando, A; Andrault, T; Antonietti, H; Anzai, S; Arkoun, G; Avenoso, C; Ayrault, D; Banasiewicz, M; Banaśkiewicz, M; Bernardini, L; Bernard, E; Berthet, E; Blanchard, M; Boreyko, D; Boros, K; Charron, S; Cornette, P; Czerkas, K; Dameron, M; Date, I; De Pontbriand, M; Demangeau, F; Dobaczewski, Ł; Dobrzyński, L; Ducouret, A; Dziedzic, M; Ecalle, A; Edon, V; Endo, K; Endo, T; Endo, Y; Etryk, D; Fabiszewska, M; Fang, S; Fauchier, D; Felici, F; Fujiwara, Y; Gardais, C; Gaul, W; Gurin, L; Hakoda, R; Hamamatsu, I; Handa, K; Haneda, H; Hara, T; Hashimoto, M; Hashimoto, T; Hashimoto, K; Hata, D; Hattori, M; Hayano, R; Hayashi, R; Higasi, H; Hiruta, M; Honda, A; Horikawa, Y; Horiuchi, H; Hozumi, Y; Ide, M; Ihara, S; Ikoma, T; Inohara, Y; Itazu, M; Ito, A; Janvrin, J; Jout, I; Kanda, H; Kanemori, G; Kanno, M; Kanomata, N; Kato, T; Kato, S; Katsu, J; Kawasaki, Y; Kikuchi, K; Kilian, P; Kimura, N; Kiya, M; Klepuszewski, M; Kluchnikov, E; Kodama, Y; Kokubun, R; Konishi, F; Konno, A; Kontsevoy, V; Koori, A; Koutaka, A; Kowol, A; Koyama, Y; Kozioł, M; Kozue, M; Kravtchenko, O; Kruczała, W; Kudła, M; Kudo, H; Kumagai, R; Kurogome, K; Kurosu, A; Kuse, M; Lacombe, A; Lefaillet, E; Magara, M; Malinowska, J; Malinowski, M; Maroselli, V; Masui, Y; Matsukawa, K; Matsuya, K; Matusik, B; Maulny, M; Mazur, P; Miyake, C; Miyamoto, Y; Miyata, K; Miyata, K; Miyazaki, M; Molȩda, M; Morioka, T; Morita, E; Muto, K; Nadamoto, H; Nadzikiewicz, M; Nagashima, K; Nakade, M; Nakayama, C; Nakazawa, H; Nihei, Y; Nikul, R; Niwa, S; Niwa, O; Nogi, M; Nomura, K; Ogata, D; Ohguchi, H; Ohno, J; Okabe, M; Okada, M; Okada, Y; Omi, N; Onodera, H; Onodera, K; Ooki, S; Oonishi, K; Oonuma, H; Ooshima, H; Oouchi, H; Orsucci, M; Paoli, M; Penaud, M; Perdrisot, C; Petit, M; Piskowski, A; Płocharski, A; Polis, A; Polti, L; Potsepnia, T; Przybylski, D; Pytel, M; Quillet, W; Remy, A; Robert, C; Sadowski, M; Saito, M; Sakuma, D; Sano, K; Sasaki, Y; Sato, N; Schneider, T; Schneider, C; Schwartzman, K; Selivanov, E; Sezaki, M; Shiroishi, K; Shustava, I; Śniecińska, A; Stalchenko, E; Staroń, A; Stromboni, M; Studzińska, W; Sugisaki, H; Sukegawa, T; Sumida, M; Suzuki, Y; Suzuki, K; Suzuki, R; Suzuki, H; Suzuki, K; Świderski, W; Szudejko, M; Szymaszek, M; Tada, J; Taguchi, H; Takahashi, K; Tanaka, D; Tanaka, G; Tanaka, S; Tanino, K; Tazbir, K; Tcesnokova, N; Tgawa, N; Toda, N; Tsuchiya, H; Tsukamoto, H; Tsushima, T; Tsutsumi, K; Umemura, H; Uno, M; Usui, A; Utsumi, H; Vaucelle, M; Wada, Y; Watanabe, K; Watanabe, S; Watase, K; Witkowski, M; Yamaki, T; Yamamoto, J; Yamamoto, T; Yamashita, M; Yanai, M; Yasuda, K; Yoshida, Y; Yoshida, A; Yoshimura, K; Żmijewska, M; Zuclarelli, E

    2016-03-01

    Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014. In total 216 high-school students and teachers participated in the study. Each participant wore an electronic personal dosimeter 'D-shuttle' for two weeks, and kept a journal of his/her whereabouts and activities. The distributions of annual external doses estimated for each region overlap with each other, demonstrating that the personal external individual doses in locations where residence is currently allowed in Fukushima Prefecture and in Belarus are well within the range of estimated annual doses due to the terrestrial background radiation level of other regions/countries.

  1. Development of radiation detection and measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Moon, B. S.; Ham, C. S.; Chung, C. E. and others

    2000-03-01

    This report contains descriptions on the following six items. The first item is the result of a study on CsI(TI) crystals with their light emitting characteristics and the result of a study on plastic scintillators. The second item is the result of a study on advanced radiation detectors and includes experiments for the effect of using a Compton suppressor with an HPGe detector. For the third item, we describe the results of a design work done using EGS4 for a thickness gauge, a density gauge, and a level gauge. The fourth item contains descriptions on the prototype circuit systems developed for a level gauge, a thickness gauge, and for a survey meter. The fifth part contains the computed tomography algorithm and a prototype scanning system developed for a CT system. As the sixth and the last item, we describe the prototype high precision heat source and the prototype heat-voltage converter which we have designed and fabricated.

  2. Oxidative Stress Markers in Prostate Cancer Patients after HDR Brachytherapy Combined with External Beam Radiation

    OpenAIRE

    Alina Woźniak; Rafał Masiak; Michał Szpinda; Celestyna Mila-Kierzenkowska; Bartosz Woźniak; Roman Makarewicz; Anna Szpinda

    2012-01-01

    Assessment of oxidative stress markers was perfomed in prostate cancer (PCa) patients subjected to high-dose brachytherapy (HDR) with external beam radiotherapy (EBRT). Sixty men with PCa were subjected to combined two-fraction treatment with HDR (tot. 20 Gy) and EBRT (46 Gy). Blood samples were taken before treatment, immediately afterwards, after 1.5–3 months, and approx. 2 years. Control group consisted of 30 healthy men. Erythrocyte glutathione peroxidase activity in the patients was lowe...

  3. Modeling, simulation and measurement of radiation exposure using electronic personal dosimeters on realistic and ICRU phantoms

    CERN Document Server

    Fuelle, D

    2003-01-01

    Exposure studies with voxel phantoms were carried out to understand the new personal dose measurand Hp(10) measured by personal dosimeters under realistic wearing conditions. Two simulated realistic voxel phantoms and the dosimeter assembly are described in a first step. Conditions such as photon fluence, radiation field geometry, and photon energy for simulating the external photon fields at the realistic model are specified. Person-related effective doses are calculated to evaluate the personal dose. The relation between measured deep personal dose and effective dose is demonstrated and discussed by means of the simulated response function of the dosimeters at realistic phantoms.

  4. Accurate and Fast Localization of Prostate for External Beam Radiation Therapy

    Science.gov (United States)

    2009-03-01

    kilovoltage cone-beam computed tomography in radiation therapy”, oral presentation in 2008 AAPM Annual Meeting, (selected for long presentation at...dose x- ray fluoroscopy”, poster presentation in 2008 AAPM Annual Meeting, Houston, TX 6. L. Zhu, J. Wang, Y. Xie, J. Starman, R. Fahrig, and L. Xing...A patient set-up protocol based on partially blocked cone-beam CT”, poster presentation in 2008 AAPM Annual Meeting, Houston, TX 7. J. Wang, T

  5. [Non-targeted effects (bystander, abscopal) of external beam radiation therapy: an overview for the clinician].

    Science.gov (United States)

    Sun, R; Sbai, A; Ganem, G; Boudabous, M; Collin, F; Marcy, P-Y; Doglio, A; Thariat, J

    2014-12-01

    Radiotherapy is advocated in the treatment of cancer of over 50 % of patients. It has long been considered as a focal treatment only. However, the observation of effects, such as fatigue and lymphopenia, suggests that systemic effects may also occur. The description of bystander and abscopal effects suggests that irradiated cells may exert an action on nearby or distant unirradiated cells, respectively. A third type of effect that involves feedback interactions between irradiated cells was more recently described (cohort effect). This new field of radiation therapy is yet poorly understood and the definitions suffer from a lack of reproducibility in part due to the variety of experimental models. The bystander effect might induce genomic instability in non-irradiated cells and is thus extensively studied for a potential risk of radiation-induced cancer. From a therapeutic perspective, reproducing an abscopal effect by using a synergy between ionizing radiation and immunomodulatory agents to elicit or boost anticancer immune responses is an interesting area of research. Many applications are being developed in particular in the field of hypofractionated stereotactic irradiation of metastatic disease. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  6. External doses to 350 m zone residents due to anisotropic radiation from the JCO criticality accident in Tokai-mura

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Jun [Hiroshima Univ., Research Institute for Radiation Biology and Medicine, International Radiation Information Center, Kasumi, Hiroshima (Japan)

    2001-11-01

    The validity of method on the individual dose reconstruction based on the anisotropic radiation distribution was confirmed by comparison with dose from Na-24 whole body counting for the seven persons in the western side neighbor company of JCO campus. The successful coincidence between D{sub i} (Na-24) and D{sub i} (Present) also supports the validity of the second version of D(r) reported by Head Office of Countermeasure. The present dose reconstruction for the 350 m zone in the western side showed average value of 0.7 mSv and maximal value of 3.1 mSv, as indoor-dose under the assumption of effective transmittance of 0.4 for all the houses. If all the residents in 350 m zone were indoors during the accident, 83% of them might have received external doses of less than 1 mSv. Radiation exposure to the nearest residential area in the southern west direction was significantly reduced with I(O{sub j}) between 0.4 and 0.2 by several buildings in JCO campus. The present study on public dose confirms that the official report on public dose (the maximal value of 21 mSv for individual dose) from Head Office of Countermeasure is significantly overestimated due to their isotropic treatment of radiation from the source. (author)

  7. External doses to 350 m zone residents due to anisotropic radiation from the JCO criticality accident in Tokai-mura.

    Science.gov (United States)

    Takada, J

    2001-09-01

    The validity of a method for individual dose reconstruction based on the anisotropic radiation distribution was confirmed by a comparison with the dose from Na-24 whole-body counting for seven persons at a neighboring company located on the western side of the JCO campus. The successful coincidence between Di (Na-24) and Di (present) also supports the validity of the second version of D(r) reported by the Head Office of Countermeasure. The present dose reconstruction for the 350 m zone at the western side showed an average value of 0.7 mSv and a maximal value of 3.1 mSv, as indoor-dose under the assumption of an effective transmittance of 0.4 for all of the houses. If all of the residents in 350 m zone were indoors during the accident, 83% of them might have received external doses of less than 1 mSv. The radiation exposure to the nearest residential area in the southern-west direction was significantly reduced with phi(theta(i)) between 0.4 and 0.2 by several buildings on the JCO campus. The present study on the public dose confirms that the official report on the public dose (the maximal value of 21 mSv for individual doses) from Head Office of Countermeasure is significantly overestimated due to their isotropic treatment of radiation from the source.

  8. Radiation risk estimation based on measurement error models

    CERN Document Server

    Masiuk, Sergii; Shklyar, Sergiy; Chepurny, Mykola; Likhtarov, Illya

    2017-01-01

    This monograph discusses statistics and risk estimates applied to radiation damage under the presence of measurement errors. The first part covers nonlinear measurement error models, with a particular emphasis on efficiency of regression parameter estimators. In the second part, risk estimation in models with measurement errors is considered. Efficiency of the methods presented is verified using data from radio-epidemiological studies.

  9. Hypnosis modulates behavioural measures and subjective ratings about external and internal awareness.

    Science.gov (United States)

    Demertzi, Athena; Vanhaudenhuyse, Audrey; Noirhomme, Quentin; Faymonville, Marie-Elisabeth; Laureys, Steven

    2015-12-01

    In altered subjective states, the behavioural quantification of external and internal awareness remains challenging due to the need for reports on the subjects' behalf. With the aim to characterize the behavioural counterpart of external and internal awareness in a modified subjective condition, we used hypnosis during which subjects remain fully responsive. Eleven right-handed subjects reached a satisfactory level of hypnotisability as evidenced by subjective reports on arousal, absorption and dissociation. Compared to normal wakefulness, in hypnosis (a) participants' self-ratings for internal awareness increased and self-ratings for external awareness decreased, (b) the two awareness components tended to anticorrelate less and the switches between external and internal awareness self-ratings were less frequent, and (c) participants' reaction times were higher and lapses in key presses were more frequent. The identified imbalance between the two components of awareness is considered as of functional relevance to subjective (meta)cognition, possibly mediated by allocated attentional properties brought about by hypnosis. Our results highlight the presence of a cognitive counterpart in resting state, indicate that the modified contents of awareness are measurable behaviourally, and provide leverage for investigations of more challenging altered conscious states, such as anaesthesia, sleep and disorders of consciousness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Radiation dose measurement of paediatric patients in Estonia

    Energy Technology Data Exchange (ETDEWEB)

    Kepler, K. [Training Centre of Medical Physics and Biomedical Engineering, University of Tartu (Estonia); Lintrop, M. [Department of Radiology, Tartu University Hospital, Tartu (Estonia); Servomaa, A.; Parviainen, T. [STUK - Radiation and Nuclear Safety Authority, Helsinki (Finland); Eek, V.; Filippova, I. [Estonian Radiation Protection Centre, Tallinn (Estonia)

    2003-06-01

    According to the Medical Exposure Directive (97/43/Euratom) the radiation doses to patients should be measured in every hospital and doses should be compared to the reference doses established by the competent authorities. Special attention should be paid to the paediatric x-ray examinations, because the paediatric patients are more radiosensitive than adult patients. The requirement of measurements of radiation dose to patients is not yet included in the Estonian radiation act, but the purpose to join the European Communities makes the quality control in radiology very actual in Estonia. The necessity exists to introduce suitable measurement methods in the Xray departments of Estonian hospitals for establishing feedback system for radiologists, radiographers and medical physicists in optimising the radiation burden of patients and image quality. (orig.)

  11. Optical fibers and their applications for radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kakuta, Tsunemi [Japan Atomic Energy Research Inst., Tokyo (Japan)

    1998-07-01

    When optical fibers are used in a strong radiation field, it is necessary to increase the radiation-resistant capacity. Aiming at the improvement of such property, the characteristics of recent optical fibers made from quartz-glass were reviewed and the newly developed techniques for radiation measurement using those fibers were summarized in this report. Since optical fibers became able to use in the levels near the core conditions, their applications have started in various fields of technologies related to radiation. By combining the optical fibers and a small sensor, it became possible to act as `Key Component` for measuring wide range radioactivity from a trace activity to a strong radiation field in the reactor core. Presently, the fibers are utilized for investigation of the optical mechanisms related in radiation, evaluation of their validities so on. Further, the optical fibers are expected to utilize in a multi-parametric measuring system which allows to concomitantly determine the radiation, temperature, pressure, flow amount etc. as an incore monitor. (M.N.)

  12. ISS and Space Shuttle Radiation Measurements at Solar Minimum

    Science.gov (United States)

    Gaza, Ramona; Welton, Andrew; Dunegan, Audrey; Lee, Kerry

    2011-01-01

    A summary of 2008-2011 ISS and Space Shuttle radiation dosimetry results for inside vehicle radiation monitoring in low-Earth orbit will be presented. Results include new data from ISS Expedition 22-25/20A radiation area monitors (RAM) and Shuttle Missions STS127-STS133 passive radiation dosimeters (PRD). ISS 20A radiation measurement locations included three Node 2 crew quarters locations at NOD2S5_CQ, NOD2P5_CQ and CQ-3 (Deck), as well as ESA Columbus, and JAXA Kibo locations. ISS 20A and STS127-STS133 missions were flown at 51.6 inclination with an altitude range of 330-350 km. The passive radiation results will be presented in terms of measured daily dose obtained using luminescence detectors (i.e., Al2O3:C, LiF:Mg,Ti and CaF2:Tm). In addition, preliminary results from the DOSIS 2 Project, in collaboration with the German Space Agency (DLR) will be presented. SRAG s participation to the DOSIS 2 exposure on ISS (11/16/2009-05/26/2010) involved passive radiation measurements at 10 different shielding locations inside the ESA Columbus Module.

  13. Space weather effects measured in atmospheric radiation on aircraft

    Science.gov (United States)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Wieman, S. R.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, L. D.; Mertens, C. J.; Xu, X.; Wiltberger, M. J.; Wiley, S.; Teets, E.; Shea, M. A.; Smart, D. F.; Jones, J. B. L.; Crowley, G.; Azeem, S. I.; Halford, A. J.

    2016-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Since 2013 Space Environment Technologies (SET) has been conducting observations of the atmospheric radiation environment at aviation altitudes using a small fleet of six instruments. The objective of this work is to improve radiation risk management in air traffic operations. Under the auspices of the Automated Radiation Measurements for Aerospace Safety (ARMAS) and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) projects our team is making dose rate measurements on multiple aircraft flying global routes. Over 174 ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the radiation environment resulting from Galactic Cosmic Rays (GCRs), Solar Energetic Protons (SEPs), and outer radiation belt energetic electrons. The real-time radiation exposure is measured as an absorbed dose rate in silicon and then computed as an ambient dose equivalent rate for reporting dose relevant to radiative-sensitive organs and tissue in units of microsieverts per hour. ARMAS total ionizing absorbed dose is captured on the aircraft, downlinked in real-time, processed on the ground into ambient dose equivalent rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users. Dose rates from flight altitudes up to 56,700 ft. are shown for flights across the planet under a variety of space weather conditions. We discuss several space weather

  14. Measurement of radiative widths at COMPASS

    CERN Document Server

    Krämer, Markus

    2014-01-01

    COMPASS is a multipurpose fixed-target experiment at the CERN SPS, which addresses a wide variety of physic topics, in particular the structure and spectroscopy of hadrons. Diffractive dissociation of pions on nuclear targets allows for clean access to the light meson spectrum. In addition meson production can be studied in pion-photon reactions via the Primakoff effect, where high-energetic pions react with the quasi-real photon field surrounding the target nuclei. At low pion-photon center-of-mass energies, these reactions are governed by chiral dynamics and contain information relevant for chiral perturbation theory. At higher energies, resonances are produced and their radiative coupling is investigated. During a short run using a 190GeV $\\pi^-$ beam and a lead target in the year 2004, 3 million exclusive $\\pi^-\\pi^-\\pi^+$ events in the region of small squared four-momentum transfer, i.e. t' < 0:01GeV$^2$=c$^2$, have been recorded. At very low t' < 0:001GeV$^2$=c$^2$, the contribution from electroma...

  15. An assessment of bias and uncertainty in recorded dose from external sources of radiation for workers at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Fix, J.J.; Gilbert, E.S.; Baumgartner, W.V.

    1994-08-01

    Worker dose estimates are used in epidemiologic studies of nuclear workers. A major objective of these studies is to provide a direct assessment of the carcinogenic risk of exposure to ionizing radiation at low doses and dose rates. If dose estimates used in analyses of worker data are biased, then risk estimates expressed per unit of dose will also be biased. In addition, random error in dose estimates may lead to underestimation of risk coefficients and can also distort dose-response analyses. Analyses of data from nuclear worker studies, including Hanford, have typically not been adjusted for biases and uncertainties in dose estimates in part because of the lack of adequate information on the nature and magnitude of these biases and uncertainties. This report describes an approach used to assess bias and uncertainty in radiation dose for Hanford dosimetry systems. The approach can be considered as an elaboration of work conducted by a technical committee appointed by the National Academy of Sciences (NAS) used to quantify the bias and uncertainty in estimated doses for personnel exposed to radiation as a result of atmospheric testing of nuclear weapons between 1945 and 1962. In addition, laboratory studies were conducted to measure bias for selected sources of photon radiation resulting from angular response characteristics of Hanford dosimeter systems. An overall assessment is presented of bias and uncertainty for photon radiation greater than 100 keV. This radiation is expected to have caused the vast majority of recorded dose for Hanford workers.

  16. Measurement of radiation dose in dental radiology.

    Science.gov (United States)

    Helmrot, Ebba; Alm Carlsson, Gudrun

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs.

  17. A.c. Power Measurement Using Power Analyzer Associated with External Transducers. Accuracy and Uncertainty Evaluation

    Directory of Open Access Journals (Sweden)

    Marinel Popescu

    2014-09-01

    Full Text Available The development of the digital signal processors and their implementation in measuring technique has led to the manufacturing of power analyzers used as multifunction meters in industry, automation, tests and laboratory activities, monitoring and control of processes, etc. The parameters of a three-phase system can be known if the phase currents, the phase voltages and the phase difference between them can be known.A power analyzer has six inputs for currents and voltages measuring signals. The paper presents a method of determination of errors and uncertainties of electrical quantities measurement using a power analyzer associated with external transducers. The best estimation of measured quantity and uncertainty of measurement are used to report the result of measurement process.

  18. The definition analyses of radiation temperature measurement area

    Institute of Scientific and Technical Information of China (English)

    Fu Tairan; Cheng Xiaofang; Zhong Maohua

    2008-01-01

    In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation tem-perature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and im-proved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity co-ordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications.

  19. Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter

    NARCIS (Netherlands)

    Ridder, van de L.; Hakvoort, W.B.J.; Dijk, van J.; Lötters, J.C.; Boer, de A.

    2014-01-01

    In this paper the influence of external vibrations on the measurement value of a Coriolis mass-flow meter (CMFM) for low flows is investigated and quantified. Model results are compared with experimental results to improve the knowledge on how external vibrations affect the mass-flow measurement val

  20. Dose painting to treat single-lobe prostate cancer with hypofractionated high-dose radiation using targeted external beam radiation: Is it feasible?

    Energy Technology Data Exchange (ETDEWEB)

    Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.; Ryan, Nicole; Raben, David, E-mail: david.raben@ucdenver.edu

    2015-10-01

    Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involved lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V{sub 70} (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V{sub 70} was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB.

  1. Predictors of urinary and rectal toxicity after external conformed radiation therapy in prostate cancer: Correlation between clinical, tumour and dosimetric parameters and radical and postoperative radiation therapy.

    Science.gov (United States)

    Martínez-Arribas, C M; González-San Segundo, C; Cuesta-Álvaro, P; Calvo-Manuel, F A

    2017-06-15

    To determine rectal and urinary toxicity after external beam radiation therapy (EBRT), assessing the results of patients who undergo radical or postoperative therapy for prostate cancer (pancreatic cancer) and their correlation with potential risk factors. A total of 333 patients were treated with EBRT. Of these, 285 underwent radical therapy and 48 underwent postoperative therapy (39 cases of rescue and 9 of adjuvant therapy). We collected clinical, tumour and dosimetric variable to correlate with toxicity parameters. We developed decision trees based on the degree of statistical significance. The rate of severe acute toxicity, both urinary and rectal, was 5.4% and 1.5%, respectively. The rate of chronic toxicity was 4.5% and 2.7%, respectively. Twenty-seven patients presented haematuria, and 9 presented haemorrhagic rectitis. Twenty-five patients (7.5%) presented permanent limiting sequela. The patients with lower urinary tract symptoms prior to the radiation therapy presented poorer tolerance, with greater acute bladder toxicity (P=0.041). In terms of acute rectal toxicity, 63% of the patients with mean rectal doses >45Gy and anticoagulant/antiplatelet therapy developed mild toxicity compared with 37% of the patients with mean rectal doses <45 Gy and without anticoagulant therapy. We were unable to establish predictors of chronic toxicity in the multivariate analysis. The long-term sequelae were greater in the patients who underwent urological operations prior to the radiation therapy and who were undergoing anticoagulant therapy. The tolerance to EBRT was good, and severe toxicity was uncommon. Baseline urinary symptoms constitute the predictor that most influenced the acute urinary toxicity. Rectal toxicity is related to the mean rectal dose and with anticoagulant/antiplatelet therapy. There were no significant differences in severe toxicity between radical versus postoperative radiation therapy. Copyright © 2017 AEU. Publicado por Elsevier España, S

  2. Organ-confined prostate carcinoma radiation brachytherapy compared with external either photon- or hadron-beam radiation therapy. Just a short up-to-date.

    Science.gov (United States)

    Alberti, C

    2011-07-01

    Both low dose rate (LDR) permanent either 1251 or 103Pd seed implant and high dose rate (HDR) 1921r temporary implant are an excellent way to release high dose of ionizing radiations to cancerous lesions while significantly sparing the surrounding healthy tissues. Therefore, the radiation brachytherapy, among the established treatment options of organ-confined prostate carcinoma--interstitial radiofrequency, high intensity focused ultrasound, cryotherapy--has gained large acceptance in the last decades. The LDR permanent interstitial radioactive seed implantation is often used as monotherapy for low risk prostate carcinoma whereas the HDR temporary implant may useful to treat intermediate-to-high risk prostate tumors as a radiation boost to combined external beam radiation therapy (EBRT). On the other hand, with recent refinement of EBRT techniques--either three-dimensional conformal- or intensity-modulated radiotherapy, cyber-knife radiosurgery with even 4D-high resolution image-guided tracking--high doses of X-rays may be precisely delivered to prostate malignant lesions without increasing toxicity for surrounding normal structures. Also hadron therapy is an increasingly successful technique that allows the release of effective energy of protons (H+), neutrons or carbon ions (6(12)C) to the limited extent of the cancerous target site, thus destroying malignant lesion with millimetric precision--just as bloodless surgery--while less damaging the neighbouring healthy tissues. Looking to the near future, even more effective oncotherapy modality appears to be the use of antiprotons because of their highly confined energy deposition at well defined body dept around the annihilation point in contact with protons of the ordinary matter, so targeting only a very limited body volume.

  3. Atmospheric Radiation Measurement Climate Research Facility (ACRF) Annual Report 2008

    Energy Technology Data Exchange (ETDEWEB)

    LR Roeder

    2008-12-01

    The Importance of Clouds and Radiation for Climate Change: The Earth’s surface temperature is determined by the balance between incoming solar radiation and thermal (or infrared) radiation emitted by the Earth back to space. Changes in atmospheric composition, including greenhouse gases, clouds, and aerosols, can alter this balance and produce significant climate change. Global climate models (GCMs) are the primary tool for quantifying future climate change; however, there remain significant uncertainties in the GCM treatment of clouds, aerosol, and their effects on the Earth’s energy balance. In 1989, the U.S. Department of Energy (DOE) Office of Science created the Atmospheric Radiation Measurement (ARM) Program to address scientific uncertainties related to global climate change, with a specific focus on the crucial role of clouds and their influence on the transfer of radiation in the atmosphere. To reduce these scientific uncertainties, the ARM Program uses a unique twopronged approach: • The ARM Climate Research Facility, a scientific user facility for obtaining long-term measurements of radiative fluxes, cloud and aerosol properties, and related atmospheric characteristics in diverse climate regimes; and • The ARM Science Program, focused on the analysis of ACRF and other data to address climate science issues associated with clouds, aerosols, and radiation, and to improve GCMs. This report provides an overview of each of these components and a sample of achievements for each in fiscal year (FY) 2008.

  4. Live-cell imaging to detect phosphatidylserine externalization in brain endothelial cells exposed to ionizing radiation: implications for the treatment of brain arteriovenous malformations.

    Science.gov (United States)

    Zhao, Zhenjun; Johnson, Michael S; Chen, Biyi; Grace, Michael; Ukath, Jaysree; Lee, Vivienne S; McRobb, Lucinda S; Sedger, Lisa M; Stoodley, Marcus A

    2016-06-01

    OBJECT Stereotactic radiosurgery (SRS) is an established intervention for brain arteriovenous malformations (AVMs). The processes of AVM vessel occlusion after SRS are poorly understood. To improve SRS efficacy, it is important to understand the cellular response of blood vessels to radiation. The molecular changes on the surface of AVM endothelial cells after irradiation may also be used for vascular targeting. This study investigates radiation-induced externalization of phosphatidylserine (PS) on endothelial cells using live-cell imaging. METHODS An immortalized cell line generated from mouse brain endothelium, bEnd.3 cells, was cultured and irradiated at different radiation doses using a linear accelerator. PS externalization in the cells was subsequently visualized using polarity-sensitive indicator of viability and apoptosis (pSIVA)-IANBD, a polarity-sensitive probe. Live-cell imaging was used to monitor PS externalization in real time. The effects of radiation on the cell cycle of bEnd.3 cells were also examined by flow cytometry. RESULTS Ionizing radiation effects are dose dependent. Reduction in the cell proliferation rate was observed after exposure to 5 Gy radiation, whereas higher radiation doses (15 Gy and 25 Gy) totally inhibited proliferation. In comparison with cells treated with sham radiation, the irradiated cells showed distinct pseudopodial elongation with little or no spreading of the cell body. The percentages of pSIVA-positive cells were significantly higher (p = 0.04) 24 hours after treatment in the cultures that received 25- and 15-Gy doses of radiation. This effect was sustained until the end of the experiment (3 days). Radiation at 5 Gy did not induce significant PS externalization compared with the sham-radiation controls at any time points (p > 0.15). Flow cytometric analysis data indicate that irradiation induced growth arrest of bEnd.3 cells, with cells accumulating in the G2 phase of the cell cycle. CONCLUSIONS Ionizing radiation

  5. Generation of 13.9 m radiation from CO2 by cascade lasing or externally applied CO2 laser

    Indian Academy of Sciences (India)

    Utpal Nundy

    2010-11-01

    13.9 m radiation from the 1000–0110 transition can be obtained from a CO2 laser by saturating the 0001–1000, 10.6 m transition with an internally generated q-switched pulse or by the application of an external 10.6 m pulse. Because of Fermi resonance between the symmetric stretch and the bending modes, decay of population from the 1000 level is fast, and such lasers operate at low power and energies. A theoretical model was developed to study such lasers. The results of the calculations indicate that a large-aperture E-beam-sustained discharge is effective for excitation of the cryogenically cooled gain medium, which uses He rich mixture at low pressure. The system is scalable and capable of generating large powers and energies.

  6. Total heart volume as a function of clinical and anthropometric parameters in a population of external beam radiation therapy patients

    Science.gov (United States)

    Nadège Ilembe Badouna, Audrey; Veres, Cristina; Haddy, Nadia; Bidault, François; Lefkopoulos, Dimitri; Chavaudra, Jean; Bridier, André; de Vathaire, Florent; Diallo, Ibrahima

    2012-01-01

    The aim of this paper was to determine anthropometric parameters leading to the least uncertain estimate of heart size when connecting a computational phantom to an external beam radiation therapy (EBRT) patient. From computed tomography images, we segmented the heart and calculated its total volume (THV) in a population of 270 EBRT patients of both sexes, aged 0.7-83 years. Our data were fitted using logistic growth functions. The patient age, height, weight, body mass index and body surface area (BSA) were used as explanatory variables. For both genders, good fits were obtained with both weight (R2 = 0.89 for males and 0.83 for females) and BSA (R2 = 0.90 for males and 0.84 for females). These results demonstrate that, among anthropometric parameters, weight plays an important role in predicting THV. These findings should be taken into account when assigning a computational phantom to a patient.

  7. Measurement and Modeling of Particle Radiation in Coal Flames

    DEFF Research Database (Denmark)

    Bäckström, Daniel; Johansson, Robert; Andersson, Klas Jerker

    2014-01-01

    This work aims at developing a methodology that can provide information of in-flame particle radiation in industrial-scale flames. The method is based on a combination of experimental and modeling work. The experiments have been performed in the high-temperature zone of a 77 kWth swirling lignite...... properties. The in-flame particle radiation was measured with a Fourier transform infrared (FTIR) spectrometer connected to a water-cooled probe via fiber optics. In the cross-section of the flame investigated, the particles were found to be the dominating source of radiation. Apart from giving information...

  8. Calculations of internal and external radiation exposure based on voxel models. Final report; Berechnungen der internen und externen Strahlenexposition auf Grundlage von Voxel-Modellen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Zankl, M. [Helmholtz Zentrum Muenchen - Deutsches Forschungszentrum fuer Gesundheit und Umwelt, Muenchen (Germany). Inst fuer Strahlenschutz; Becker, J.; Petoussi-Henss, N.; Schlattl, H.

    2012-02-15

    Dose estimations of internal and external radiation exposure were based so far on mathematical phantoms with rather simple geometrical descriptions of the human body and teh organs. Recently the mathematical phantoms are replaced by more realistic voxel models that allow a more realistic dose estimation for professional radiation exposed personnel, individuals and patients. The projects is aimed to calculate organ doses for exposure to environmental radiation, organ doses for patients during computed tomography and to develop a voxel model for pregnant (24th week of pregnancy) woman for the estimation of radiation doses for the unborn child.

  9. Natural Radioactivity Measurements and Radiation Dose Estimation in Some Sedimentary Rock Samples in Turkey

    Directory of Open Access Journals (Sweden)

    I. Akkurt

    2014-01-01

    Full Text Available The natural radioactivity existed since creation of the universe due to the long life time of some radionuclides. This natural radioactivity is caused by γ-radiation originating from the uranium and thorium series and 40K. In this study, the gamma radiation has been measured to determine natural radioactivity of 238U, 232Th, and 40K in collected sedimentary rock samples in different places of Turkey. The measurements have been performed using γ-ray spectrometer containing NaI(Tl detector and multichannel analyser (MCA. Absorbed dose rate (D, annual effective dose (AED, radium equivalent activities (Raeq, external hazard index (Hex, and internal hazard index (Hin associated with the natural radionuclide were calculated to assess the radiation hazard of the natural radioactivity in the sedimentary rock samples. The average values of absorbed dose rate in air (D, annual effective dose (AED, radium equivalent activity (Raeq, external hazard index (Hex, and internal hazard index (Hin were calculated and these were 45.425 nGy/h, 0.056 mSv/y, 99.014 Bq/kg, 0.267, and 0.361, respectively.

  10. Coordinated weather balloon solar radiation measurements during a solar eclipse

    Science.gov (United States)

    2016-01-01

    Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes. This article is part of the themed issue ‘Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse’. PMID:27550757

  11. Coordinated weather balloon solar radiation measurements during a solar eclipse.

    Science.gov (United States)

    Harrison, R G; Marlton, G J; Williams, P D; Nicoll, K A

    2016-09-28

    Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'.

  12. Using Radiation Pattern Measurements for Mobile Handset Performance Evaluation

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2005-01-01

    The mean effective gain (MEG) is an attractive performance measure of mobile handsets, since it incorporates both directional and polarization properties of the handset and environment. In this work the MEG is computed from measured spherical radiation patterns of five different mobile handsets......, both in free space and including a human head & shoulder phantom. Different models of the environment allow a comparison of the MEG obtained for realistic models based on measurements with the total radiated power (TRP) and the total isotropic sensitivity (TIS). All the comparisons are based on the MEG...

  13. Mobile Handset Performance Evaluation Using Radiation Pattern Measurements

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2006-01-01

    The mean effective gain is an attractive performance measure of mobile handsets, since it incorporates both directional and polarization properties of the handset and environment. In this work the mean effective gain is computed from measured spherical radiation patterns of five different mobile...... handsets, both in free space and including a human head & shoulder phantom. Different models of the environment allow a comparison of the mean effective gain obtained for realistic models based on measurements with the total radiated power and the total isotropic sensitivity. All the comparisons are based...

  14. Comparison of childhood thyroid cancer prevalence among 3 areas based on external radiation dose after the Fukushima Daiichi nuclear power plant accident: The Fukushima health management survey.

    Science.gov (United States)

    Ohira, Tetsuya; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Midorikawa, Sanae; Suzuki, Satoru; Fukushima, Toshihiko; Shimura, Hiroki; Ishikawa, Tetsuo; Sakai, Akira; Yamashita, Shunichi; Tanigawa, Koichi; Ohto, Hitoshi; Abe, Masafumi; Suzuki, Shinichi

    2016-08-01

    The 2011 Great East Japan Earthquake led to a subsequent nuclear accident at the Fukushima Daiichi Nuclear Power Plant. In its wake, we sought to examine the association between external radiation dose and thyroid cancer in Fukushima Prefecture. We applied a cross-sectional study design with 300,476 participants aged 18 years and younger who underwent thyroid examinations between October 2011 and June 2015. Areas within Fukushima Prefecture were divided into three groups based on individual external doses (≥1% of 5 mSv, accident and thyroid examination was not associated with thyroid cancer prevalence. There were no significant associations between individual external doses and prevalence of thyroid cancer. External radiation dose was not associated with thyroid cancer prevalence among Fukushima children within the first 4 years after the nuclear accident.

  15. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    Energy Technology Data Exchange (ETDEWEB)

    Sole, C.V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Calvo, F.A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lozano, M.A.; Gonzalez-Sansegundo, C. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Gonzalez-Bayon, L. [Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Alvarez, A. [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lizarraga, S. [Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Garcia-Sabrido, J.L. [Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain)

    2014-02-15

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  16. Can endocranial volume be estimated accurately from external skull measurements in great-tailed grackles (Quiscalus mexicanus)?

    National Research Council Canada - National Science Library

    Logan, Corina J; Palmstrom, Christin R

    2015-01-01

    ...), as measured by computerized tomography (CT) scans, using external skull measurements and/or by filling skulls with beads and pouring them out into a graduated cylinder for male and female great-tailed grackles...

  17. Structural/functional relationships between internal and external MSH receptors: modulation of expression in Cloudman melanoma cells by UVB radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, A.K.; Orlow, S.J.; Bolognia, J.L.; Pawelek, J.M. (Department of Dermatology, Yale University School of Medicine, New Haven, CT (USA))

    1991-04-01

    Expression of internal receptors for MSH is an important criterion for responsiveness to MSH by Cloudman melanoma cells. Here, we show that internal and external receptors for MSH are of identical molecular weights (50-53 kDa) and share common antigenic determinants, indicating a structural relationship between the 2 populations of molecules. The internal receptors co-purified with a sub-cellular fraction highly enriched for small vesicles, many of which were coated. Ultraviolet B light (UVB) acted synergistically with MSH to increase tyrosinase activity and melanin content of cultured Cloudman melanoma cells, consistent with previous findings in the skin of mice and guinea pigs. Preceding the rise in tyrosinase activity in cultured cells, UVB elicited a decrease in internal MSH binding sites and a concomitant increase in external sites. The time frame for the UVB effects on MSH receptors and melanogenesis, 48 hours, was similar to that for a response to solar radiation in humans. Together, the results indicate a key role for MSH receptors in the induction of melanogenesis by UVB and suggest a potential mechanism of action for UVB: redistribution of MSH receptors with a resultant increase in cellular responsiveness to MSH.

  18. Estimation of participating media radiative properties with time dependent external illumination

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Acevedo, Nancy I. [Universidade do Estado, Nova Friburgo, RJ (Brazil). Instituto Politecnico. Dept. de Modelagem Computacional]. E-mail: nacevedo@iprj.uerj.br; Roberty, Nilson C.; Silva Neto, Antonio J. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: nilson@lmn.con.ufrj.br; ajsneto@lmn.con.ufrj.br; ajsneto@iprj.uerj.br

    2003-07-01

    In this work two methods for the absorption and scattering coefficients estimation in homogeneous participant media with transient data on the intensity of the radiation that leaves of the medium are investigated. The transient problem is reduced to a family of stationary problems with an absorption coefficient modified by Laplace's transform parameter s. The transient experimental data acquired at the boundaries of the medium are also Laplace transformed and the inverse problem is then solved in the transformed space. The source-detector methodology and Levenberg-Marquardt's method, are applied to investigate the simultaneous estimation of the total extinction and scattering coefficients. numerical test cases results are presented. (author)

  19. Measurements of terahertz radiation generated using a metallic, corrugated pipe

    Science.gov (United States)

    Bane, Karl; Stupakov, Gennady; Antipov, Sergey; Fedurin, Mikhail; Kusche, Karl; Swinson, Christina; Xiang, Dao

    2017-02-01

    A method for producing narrow-band THz radiation proposes passing an ultra-relativistic beam through a metallic pipe with small periodic corrugations. We present results of a measurement of such an arrangement at Brookhaven's Accelerator Test Facility (ATF). Our pipe was copper and was 5 cm long; the aperture was cylindrically symmetric, with a 1 mm (radius) bore and a corrugation depth (peak-to-peak) of 60 μm. In the experiment we measured both the effect on the beam of the structure wakefield and the spectral properties of the radiation excited by the beam. We began by injecting a relatively long beam compared to the wavelength of the radiation, but with short rise time, to excite the structure, and then used a downstream spectrometer to infer the radiation wavelength. This was followed by injecting a shorter bunch, and then using an interferometer (also downstream of the corrugated pipe) to measure the spectrum of the induced THz radiation. For the THz pulse we obtain and compare with calculations: the central frequency, the bandwidth, and the spectral power-compared to a diffraction radiation background signal.

  20. Satellite data sets for the atmospheric radiation measurement (ARM) program

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L.; Bernstein, R.L. [SeaSpace Corp., San Diego, CA (United States)

    1996-04-01

    This abstract describes the type of data obtained from satellite measurements in the Atmospheric Radiation Measurement (ARM) program. The data sets have been widely used by the ARM team to derive cloud-top altitude, cloud cover, snow and ice cover, surface temperature, water vapor, and wind, vertical profiles of temperature, and continuoous observations of weather needed to track and predict severe weather.

  1. Polarization factor measurements of flat crystals using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Wohrer, K.; Touati, A.; Chetioui, A.; Rozet, J.P.; Chevallier, P.; Wang, J.X.; Bouisset, P.

    1989-01-01

    A method for measuring polarization factors of flat crystals, using a highly polarized beam source provided by synchrotron radiation, is presented. Application to the test of a graphite mosaic crystal, performed at the LURE-DCI facility in Orsay (France), is reported. Results concerning polarization factors at different energies are discussed in connection with measured crystal reflectivities.

  2. Oxidative Stress Markers in Prostate Cancer Patients after HDR Brachytherapy Combined with External Beam Radiation

    Directory of Open Access Journals (Sweden)

    Alina Woźniak

    2012-01-01

    Full Text Available Assessment of oxidative stress markers was perfomed in prostate cancer (PCa patients subjected to high-dose brachytherapy (HDR with external beam radiotherapy (EBRT. Sixty men with PCa were subjected to combined two-fraction treatment with HDR (tot. 20 Gy and EBRT (46 Gy. Blood samples were taken before treatment, immediately afterwards, after 1.5–3 months, and approx. 2 years. Control group consisted of 30 healthy men. Erythrocyte glutathione peroxidase activity in the patients was lower than in healthy subjects by 34% (, 50% (, 30% (, and 61% (, respectively, at all periods. No significant differences were found by comparing superoxide dismutase and catalase activity in PCa patients with that of the controls. After 2 years of the end of treatment, the activity of studied enzymes demonstrated a decreasing tendency versus before therapy. Blood plasma thiobarbituric acid reactive substances (TBARS concentration was higher than in the controls at all periods, while erythrocyte TBARS decreased after 2 years to control levels. The results confirm that in the course of PCa, imbalance of oxidant-antioxidant processes occurs. The therapy did not alter the levels of oxidative stress markers, which may prove its applicability. Two years is too short a period to restore the oxidant-antioxidant balance.

  3. Validating CERES Radiative Fluxes in the Arctic with Airborne Radiative Flux Measurements from the ARISE Campaign

    Science.gov (United States)

    Corbett, J.; Bucholtz, A.; Kato, S.; Rose, F. G.; Smith, W. L., Jr.

    2015-12-01

    The Clouds and the Earth's Radiant Energy System (CERES) instruments on board NASA's Terra, Aqua, and Soumi-NPP satellites provide the only measurements of reflected solar shortwave and emitted longwave radiative flux over the Arctic. Various methods have shown the uncertainty of CERES fluxes over sea ice to be higher than other scene types. However validation against an independent radiative flux measurement has never been attempted. We present here an attempt to better quantify the uncertainty of time-and-space averaged CERES flux measurements using airborne measurements from the Arctic Radiation - IceBridge Sea Ice Experiment (ARISE). The ARISE campaign took place during September of 2014 based out of Fairbanks, Alaska, with most of the measurements taken in the vicinity of the sea ice edge between 125°W and 150°W, and 71°N to 77°N. For six of the flights, measurements were taken in a lawnmower type pattern over either 100 x 200 km box regions at a constant altitude of >6 km, or 100 x 100 km box regions at an altitude of between 200 m to 500 m. They were designed to resemble the CERES Level 3 spatial averaging grids, and were located and timed to coincide with a high number of CERES overpasses. On board the aircraft were a set of upward and downward facing shortwave and longwave broadband radiometers (BBR), along with other instruments measuring meteorological conditions and cloud properties. We have compared the broadband radiative fluxes from BBR with those from CERES for the three days where the aircraft was flying the high altitude pattern. We use the Fu-Liou radiative transfer model to account for differences in the measurement altitude between BBR and CERES. We will present results of the comparisons between the computed fluxes and the measured longwave and shortwave radiative fluxes.

  4. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    OpenAIRE

    Nee Alexander

    2016-01-01

    Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary....

  5. Pilot Study of the Delivery of Microcollimated Pars Plana External Beam Radiation in Porcine Eyes: 270-Day Analysis

    Directory of Open Access Journals (Sweden)

    Rishi P. Singh

    2012-01-01

    Full Text Available Objective. To determine the dose response and toxicity threshold of micro-collimated X-rays delivered to porcine maculae by a stereotactic radiosurgical system after 270 days. Methods. Twelve eyes of six Yucatan mini-swine were randomized to receive up to 90 Gy to the retina, using an office-based trans-pars plana delivery system. To determine the safety profile of this radiation delivery, ophthalmic examination, fundus photography, fluorescein angiography (FA, and spectral domain optical coherence tomography (SD-OCT were obtained at multiple time points up to 270 days post treatment. Results. No abnormalities were noted on external examination. Cataracts were noted in 4 of 12 eyes. Dose and time-dependent changes were noted on fundus examination, FA, ICG and SD-OCT. No significant abnormalities were seen in the control, 16 Gy or 24 Gy groups using any modality. Histopathology revealed a dose response effect with no discernable lesions in the 16 Gy group. Conclusion. The X-ray delivery system precisely targets the porcine retina in vivo with little effect on surrounding structures. No ophthalmic or intracranial adverse effects were noted at clinically relevant doses at 270 days following radiation delivery.

  6. Normal tissue tolerance to external beam radiation therapy: The mandible; Dose de tolerance des tissus sains: la mandibule

    Energy Technology Data Exchange (ETDEWEB)

    Berger, A.; Bensadoun, R.J. [Service d' oncologie radiotherapie, PRC, CHU de la Miletrie, 86 - Poitiers (France)

    2010-07-15

    Describing dose constraints for organs at risk in external beam radiotherapy is a key-point in order to maximize the therapeutic ratio. In head and neck irradiation, mandible is frequently exposed to ionising radiation-related complications. Those complications will be exposed after a short description of anatomical and physiopathological aspects. A literature search was performed using the Pubmed-Medline database, with following keywords (Osteoradionecrosis, Radiotherapy, Mandible, Toxicity, Organ at risk, Trismus). Incidence and dose constraints will be reported. The incidence of osteoradionecrosis decreased since the 1990, but it remains a dreaded late complication of head and neck cancer radiotherapy. It essentially occurs with cumulative doses of 66 Gy on the mandible (standard fractionation) applied to a significant volume. Respecting oral care is crucial to avoid this kind of complication. The respect of the dose-constraint described should not lead to under treat tumor bed in a curative intent. Trismus related to ionising radiation is poorly described. Literature data cannot lead to describe precise dose constraints. (authors)

  7. Non-contact Measurement of Damaged External Tapered Thread Based on Linear Array CCD

    Science.gov (United States)

    He, F. J.; Zhang, R. J.; Du, Z. J.; Cui, X. M.

    2006-10-01

    The non-contact measurement of external tapered thread based on linear array CCD is presented to decrease the measuring error caused by local damage area contrast to the measurement with mechanical gauges. The thread is scanned by linear array CCD and the signal is processed by first order difference to obtain thread contour. For the thread with damage on tooth flank and deformation on generating line, the Hough transform and weighted least squares are adopted to reduce the local defects and to set up fitted thread contour equations that can reflect the real dimension. Then the dimensions can be calculated based on these equations according to the definition. The paper also presents the method to evaluate the local damage. Experiment shows that the method is suitable for the measurement of damaged thread.

  8. Radiation budget and related measurements in 1985 and beyond. [earth radiation budget satellite system

    Science.gov (United States)

    1978-01-01

    Development of systems for obtaining radiation budget and cloud data is discussed. Instruments for measuring total solar irradiance, total infrared flux, reflected solar flux, and cloud heights and properties are considered. Other topics discussed include sampling by multiple satellites, user identification, and determination of the parameters that need to be measured.

  9. Increased risk of colon cancer after external radiation therapy for prostate cancer.

    Science.gov (United States)

    Rapiti, Elisabetta; Fioretta, Gerald; Verkooijen, Helena M; Zanetti, Roberto; Schmidlin, Franz; Shubert, Hyma; Merglen, Arnaud; Miralbell, Raymond; Bouchardy, Christine

    2008-09-01

    Radiotherapy can induce second cancers. Controversies still exist regarding the risk of second malignancies after irradiation for prostate cancer. We evaluated the risk of developing colon and rectum cancers after prostate cancer in irradiated and nonirradiated patients. Using data from the population-based Geneva cancer registry, we included in the study all men with prostate cancer diagnosed between 1980 and 1998 who survived at least 5 years after diagnosis. Of the 1,134 patients, 264 were treated with external radiotherapy. Patients were followed for occurrence of colorectal cancer up to 31 December, 2003. We calculated standardized incidence ratios (SIR) using incidence rates for the general population to obtain the expected cancer incidence. The cohort yielded to 3,798 person-years. At the end of follow-up 19 patients had developed a colorectal cancer. Among irradiated patients the SIR for colorectal cancer was 3.4 (95% confidence intervals [CI] 1.7-6.0). Compared to the general population, the risk was significantly higher for colon cancer (SIR = 4.0, 95% CI: 1.8-7.6), but not for rectal cancer (SIR = 2.0, 95% CI: 0.2-7.2). The risk of colon cancer was increased in the period of 5-9 years after diagnosis (SIR = 4.7, 95% CI: 2.0-9.2). The overall SIR of secondary cancer in patients treated with radiotherapy was 1.35 (p = 0.056). Nonirradiated patients did not have any increased risk of rectal or colon cancer. This study shows a significant increase of colon but not rectum cancer after radiotherapy for prostate cancer. The risk of second cancer after irradiation, although probably small, needs nevertheless to be carefully monitored.

  10. Measurement of microwave radiation from electron beam in the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, I.S.; Akimune, H. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Fukushima, M.; Ikeda, D. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Inome, Y. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Matthews, J.N. [University of Utah, Salt Lake City, UT 4112-0830 (United States); Ogio, S. [Graduate School of Science, Osaka City University, Osaka 558-8585 (Japan); Sagawa, H. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Sako, T. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Yamamoto, T., E-mail: tokonatu@konan-u.ac.jp [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan)

    2016-02-21

    We report the use of an electron light source (ELS) located at the Telescope Array Observatory in Utah, USA, to measure the isotropic microwave radiation from air showers. To simulate extensive air showers, the ELS emits an electron beam into the atmosphere and a parabola antenna system for the satellite communication is used to measure the microwave radiation from the electron beam. Based on this measurement, an upper limit on the intensity of a 12.5 GHz microwave radiation at 0.5 m from a 10{sup 18} eV air shower was estimated to be 3.96×10{sup −16} W m{sup −2} Hz{sup −1} with a 95% confidence level.

  11. Online Radiation Dose Measurement System for ATLAS experiment

    CERN Document Server

    Mandić, I; The ATLAS collaboration

    2012-01-01

    Particle detectors and readout electronics in the high energy physics experiment ATLAS at the Large Hadron Collider at CERN operate in radiation field containing photons, charged particles and neutrons. The particles in the radiation field originate from proton-proton interactions as well as from interactions of these particles with material in the experimental apparatus. In the innermost parts of ATLAS detector components will be exposed to ionizing doses exceeding 100 kGy. Energetic hadrons will also cause displacement damage in silicon equivalent to fluences of several times 10e14 1 MeV-neutrons per cm2. Such radiation doses can have severe influence on the performance of detectors. It is therefore very important to continuously monitor the accumulated doses to understand the detector performance and to correctly predict the lifetime of radiation sensitive components. Measurements of doses are important also to verify the simulations and represent a crucial input into the models used for predicting future ...

  12. 2D and 3D fault basis for fuel cell diagnosis by external magnetic field measurements

    Science.gov (United States)

    Ifrek, Lyes; Cauffet, Gilles; Chadebec, Olivier; Bultel, Yann; Rosini, Sébastien; Rouveyre, Luc

    2017-07-01

    An original approach used for the identification of faults in fuel cell stacks is presented. It is based on the 3D reconstruction of the current density from external magnetic field measurements which is an ill-posed magnetostatic linear inverse problem. A suitable and original current density and magnetic field basis are proposed in order to define both local and global faults on a fuel cell stack. The inverse problem is regularized by truncated singular value decomposition (SVD) to ensure the uniqueness of the solution. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2016)", edited by Adel Razek

  13. Measuring the security of external energy supply in the European Union

    DEFF Research Database (Denmark)

    Le Coq, Chloe; Paltseva, Elena

    2009-01-01

    studies of this kind provide aggregate indexes combining different types of energy. Our results suggest that an aggregate approach could be misleading, at least for discussions of the short-term response to risks. We discuss the implications of our findings for the common energy policy.......The security of energy supply is one of the main objectives of EU energy policy. In this paper, we introduce an index designed to evaluate the short-term risks associated with the external supply of energy to the EU Member States. It combines measures of energy import diversification, political...

  14. Measurement Of Double-radiative Pion Capture On Hydrogen

    CERN Document Server

    Tripathi, S

    2003-01-01

    The first measurement of double radiative pion capture on hydrogen is presented. The experiment was conducted at the TRIUMF cyclotron using the RMC spectrometer, and detected γ-ray coincidences following π − stops in liquid hydrogen. The branching ratio for the double radiative capture reaction was found to be (3.05 ± 0.27 (stat.) ± 0.31 (syst.)) × 10−5. The measured branching ratio and angle-energy distributions support the theoretical prediction of a dominant contribution from the π−π + → γγ annihilation mechanism.

  15. New Measurements Using External Photon Conversion at a High Luminosity B Factory

    CERN Document Server

    Ishino, H; Nakao, M; Yoshikawa, T

    2007-01-01

    We propose two novel methods for testing the standard model using external photon conversion at a high-luminosity e^+e^- B factory proposed recently. The first method is to measure the mixing-induced CP-violation parameter S_{pi^0pi^0} in B^0 --> pi^0 pi^0 decays. The precision of S_{pi^0pi^0} is estimated to be 0.23 from a Monte Carlo study for a data sample containing 50 x 10^9 BBbar pairs. We demonstrate that this measurement is crucial for reducing the discrete ambiguity of the Cabibbo-Kobayashi-Maskawa angle phi_2 determined from the isospin analysis with B --> pi pi decays. The second method is to measure photon polarization in B^0 --> K^{*0}(--> K^+ pi^-) gamma decays using the external photon conversion, and combine it with S_{K^{*}gamma} from B^0 --> K^{*0}(--> K^0_S pi^0) gamma decays. This offers a promising way of determining the hypothetical right-handed current amplitude and phase beyond the standard model.

  16. Adapting social neuroscience measures for schizophrenia clinical trials, part 3: fathoming external validity.

    Science.gov (United States)

    Olbert, Charles M; Penn, David L; Kern, Robert S; Lee, Junghee; Horan, William P; Reise, Steven P; Ochsner, Kevin N; Marder, Stephen R; Green, Michael F

    2013-11-01

    It is unknown whether measures adapted from social neuroscience linked to specific neural systems will demonstrate relationships to external variables. Four paradigms adapted from social neuroscience were administered to 173 clinically stable outpatients with schizophrenia to determine their relationships to functionally meaningful variables and to investigate their incremental validity beyond standard measures of social and nonsocial cognition. The 4 paradigms included 2 that assess perception of nonverbal social and action cues (basic biological motion and emotion in biological motion) and 2 that involve higher level inferences about self and others' mental states (self-referential memory and empathic accuracy). Overall, social neuroscience paradigms showed significant relationships to functional capacity but weak relationships to community functioning; the paradigms also showed weak correlations to clinical symptoms. Evidence for incremental validity beyond standard measures of social and nonsocial cognition was mixed with additional predictive power shown for functional capacity but not community functioning. Of the newly adapted paradigms, the empathic accuracy task had the broadest external validity. These results underscore the difficulty of translating developments from neuroscience into clinically useful tasks with functional significance.

  17. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    To harmonise the measurement of environmental dose rates from photon radiation within the EU countries. an EU sponsored intercomparison of environmental dose rate meters used for early warning of nuclear accidents was performed in June 1999. The intercomparison was organised by the EURADOS......, Physikalisch Technische Bundesanstalt (Germany) and the Riso National Laboratory (Denmark). This paper describes the free-field irradiation facilities at Rise and some details of the field intercomparison experiments performed at the Riso Natural Environmental Radiation Measurement Station during 3rd and 4th...... June, 1999. The chief aims of such experiments are to allow the participants to check their home calibrations of their detectors and to compare the responses of the individual environmental radiation measurement systems used in the different EU member states and making a link between the different...

  18. Measurements of Terahertz Radiation Generated using a Metallic, Corrugated Pipe

    CERN Document Server

    Bane, Karl; Antipov, Sergey; Fedurin, Mikhail; Kusche, Karl; Swinson, Christina; Xiang, Dao

    2016-01-01

    A method for producing narrow-band THz radiation proposes passing an ultra-relativistic beam through a metallic pipe with small periodic corrugations. We present results of a measurement of such an arrangement at Brookhaven's Accelerator Test Facility (ATF). Our pipe was copper and was 5 cm long; the aperture was cylindrically symmetric, with a 1 mm (radius) bore and a corrugation depth (peak-to-peak) of 60 um. In the experiment we measured both the effect on the beam of the structure wakefield and the spectral properties of the radiation excited by the beam. We began by injecting a relatively long beam compared to the wavelength of the radiation, but with short rise time, to excite the structure, and then used a downstream spectrometer to infer the radiation wavelength. This was followed by injecting a shorter bunch, and then using an interferometer (also downstream of the corrugated pipe) to measure the spectrum of the induced THz radiation. For the THz pulse we obtain and compare with calculations: the cen...

  19. A New Quantum Sensor for Measuring Photosynthetically Active Radiation

    Science.gov (United States)

    Johnson, D.; Thomas, T.; Heinicke, D.; Peterson, R.; Morgan, P.; McDermitt, D. K.; Burba, G. G.

    2015-12-01

    A quantum sensor measures photosynthetically active radiation (PAR, in μmol of photons m-2 s-1) in the 400 nm to 700 nm waveband. Plants utilize this radiation to drive photosynthesis, though individual plant responses to incident radiation may vary within this range. The new quantum sensor (model LI-190R, LI-COR Biosciences, Lincoln, NE), with an optical filter and silicon photodiode detector housed in a cosine-corrected head, is designed to provide a better response to incident radiation across the 400-700 nm range. The new design is expected to significantly improve spectral response due to uniformity across the PAR waveband, but particularly in the wavebands from 520 nm to 600 nm and 665 nm to 680 nm, and sharp cutoffs in the regions below and above the PAR waveband. Special care was taken to make sure that PAR sensor would not substantially respond to incident radiation above the 700 nm threshold because this can lead to errors when performing measurements in environments with a large proportion of near-infrared radiation, such as canopy understory. The physical housing of the sensor is designed to be weather-resistant, to effectively shed precipitation, provide protection at high temperature and high humidity conditions, and has a cosine-corrected response to 82° zenith angle. The latter is particularly important when measuring incident radiation at low elevation angles, diffuse light, or low light conditions. This presentation describes the principles of the new design, and shows the performance results from field experiments and laboratory tests.

  20. Leukaemia and low dose radiation. Is there an association between leukaemia and cumulative external dose amongst the British Nuclear Fuel plc. (BNFL) workers?

    Energy Technology Data Exchange (ETDEWEB)

    McGeoghegan, D.; Binks, K. [Westlakes Scientific Consulting, Cumbria (United Kingdom)

    2000-05-01

    A detailed examination of the BNFL leukaemia data is presented, for the period 1941-1995, using the recently assembled company wide BNFL epidemiological database and the BNFL leukaemia case-control data set. The association of this occupationally exposed cohort is examined with respect to both leukaemia mortality and leukaemia morbidity. The excess relative risk for total leukaemia excluding chronic lymphatic leukaemia amongst the BNFL radiation workers was found to be 3.64 Sv{sup -1} (90% CI -0.13-11.22); for Sellafield and Springfields this figure was 7.99 Sv{sup -1} (90% CI 1.50-29.5) and -1.97 Sv{sup -1} (90% CI<-2.23-6.11) respectively. A 14-20% increase in risk is noted when dosimetry adjusted for measurement error, is used to determine the excess relative risk. The association between leukaemia and cumulative external radiation is found to be particularly associated with the Sellafield plant; the Springfields plant gave consistently negative risk estimates. (author)

  1. The impact of androgen deprivation therapy on setup errors during external beam radiation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Onal, Cem; Dolek, Yemliha; Ozdemir, Yurday [Baskent University, Faculty of Medicine, Adana Dr. Turgut Noyan Research and Treatment Centre, Department of Radiation Oncology, Adana (Turkey)

    2017-06-15

    To determine whether setup errors during external beam radiation therapy (RT) for prostate cancer are influenced by the combination of androgen deprivation treatment (ADT) and RT. Data from 175 patients treated for prostate cancer were retrospectively analyzed. Treatment was as follows: concurrent ADT plus RT, 33 patients (19%); neoadjuvant and concurrent ADT plus RT, 91 patients (52%); RT only, 51 patients (29%). Required couch shifts without rotations were recorded for each megavoltage (MV) cone beam computed tomography (CBCT) scan, and corresponding alignment shifts were recorded as left-right (x), superior-inferior (y), and anterior-posterior (z). The nonparametric Mann-Whitney test was used to compare shifts by group. Pearson's correlation coefficient was used to measure the correlation of couch shifts between groups. Mean prostate shifts and standard deviations (SD) were calculated and pooled to obtain mean or group systematic error (M), SD of systematic error (Σ), and SD of random error (σ). No significant differences were observed in prostate shifts in any direction between the groups. Shifts on CBCT were all less than setup margins. A significant positive correlation was observed between prostate volume and the z-direction prostate shift (r = 0.19, p = 0.04), regardless of ADT group, but not between volume and x- or y-direction shifts (r = 0.04, p = 0.7; r = 0.03, p = 0.7). Random and systematic errors for all patient cohorts and ADT groups were similar. Hormone therapy given concurrently with RT was not found to significantly impact setup errors. Prostate volume was significantly correlated with shifts in the anterior-posterior direction only. (orig.) [German] Ziel war zu untersuchen, ob Konfigurationsfehler bei der externen Radiotherapie (RT) des Prostatakarzinoms durch die Kombination aus Androgendeprivationstherapie (ADT) und RT beeinflusst werden. Retrospektiv wurden die Daten von 175 wegen eines Prostatakarzinoms behandelten Patienten

  2. Diffraction and polarization effects in Earth radiation budget measurements.

    Science.gov (United States)

    Mahan, J R; Barki, A R; Priestley, K J

    2016-12-01

    Thermal radiation emitted and reflected from the Earth and viewed from near-Earth orbit may be characterized by its spectral distribution, its degree of coherence, and its state of polarization. The current generation of broadband Earth radiation budget instruments has been designed to minimize the effect of diffraction and polarization on science products. We used Monte Carlo ray-trace (MCRT) models that treat individual rays as quasi-monochromatic, polarized entities to explore the possibility of improving the performance of such instruments by including measures of diffraction and polarization during calibration and operation. We have demonstrated that diffraction and polarization sensitivity associated with typical Earth radiation budget instrument design features has a negligible effect on measurements.

  3. Detection and spectral measurements of coherent synchrotron radiation at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, Christopher

    2010-02-15

    The operation of high-gain free-electron laser (FEL) underlies tremendous demands on high quality electron beams with high peak currents. At the Free-Electron-Laser in Hamburg (FLASH), two magnetic bunch compressors are used to compress the electron bunches longitudinally. In the bunch compressor magnets, these short electron bunches generate coherent synchrotron radiation (CSR). This CSR contains information on the longitudinal bunch profile, which is relevant for driving an FEL. In order to investigate coherent synchrotron radiation at the second bunch compressor BC3 at FLASH, a new setup behind the last dipole was installed. For the detection of coherent synchrotron radiation, which is emitted in the infrared regime, pyroelectric detectors were used. These pyroelectric detectors have been calibrated at the free-electron laser FELIX in the wavelength range from 5 {mu}m to 110 {mu}m. For characterisation of the emitted radiation, a transverse scanning device was used to measure the transverse intensity distribution. Various transmission filters were used to obtain additional information about the spectral content. In order to get spectral information with high resolution over a wide wavelength range, a rotating mirror spectrometer using reflective blazed gratings was installed. Using this spectrometer, the first spectral measurements of coherent synchrotron radiation at FLASH in a wavelength range from 10 {mu}m to 160 {mu}m were done. (orig.)

  4. Radiation profiles measured through clouds using a return glider radiosonde

    Science.gov (United States)

    Kräuchi, Andreas; Philipona, Rolf; Kivi, Rigel

    2016-04-01

    With new and improved radiation sensors in a small glider aircraft vertical flights through clouds have been conducted. This new Return Glider Radiosonde (RG-R) is lifted up with double balloon technique to keep the radiation instruments as horizontal as possible during ascent. The RG-R is equipped with a routine radiosonde to transmit the data to a ground station and an autopilot to fly the glider radiosonde back to the launch site, where it lands autonomous with a parachute. The RG-R was successfully tested and deployed for tropospheric and stratospheric radiation measurements up to 30 hPa (24 km altitude) at the GRUAN sites Payerne (Switzerland) and Sodankylä (Finland). Radiation profiles and the radiation budget through the atmosphere during different daytimes and under cloud-free and cloudy situations will be shown in relation to temperature and humidity at the surface and in the atmosphere. The RG-R flight characteristics and new measurement possibilities will also be discussed.

  5. ionizing radiation measurements and assay of corresponding dose ...

    African Journals Online (AJOL)

    PUBLICATIONS1

    Measurements of ionizing radiation and corresponding dose rate around bottling and pharma- ceutical facilities in ... be monitored closely to protect the public from adverse health effects. Keywords: Gamma ... natural environment that we experience today. (Oke 2004 ... This decay is a phenomenon by which large number of ...

  6. Listing of solar radiation measuring equipment and glossary

    Science.gov (United States)

    Carter, E. A.; Greenbaum, S. A.; Patel, A. M.

    1976-01-01

    An attempt is made to list and provide all available information about solar radiation measuring equipment which are being manufactured and are available on the market. The list is in tabular form and includes sensor type, response time, cost data and comments for each model. A cost code is included which shows ranges only.

  7. Productivity measurement in the presence of externalities: An example from the electric power industry

    Science.gov (United States)

    Chaston, Kelly Ann

    Traditional productivity measures have ensured that environmental regulations were seen as deterrents to productivity growth. Such measures are constructed in a manner which make this conclusion inevitable. Traditional productivity measures include the regulation-induced additions to inputs, whether qualitatively or quantitatively, while continuing to ignore the value of the pollution emitted. The measure proposed in this thesis is derived formally from a model of social welfare. With the exception of 'prices' for emitted pollutants, for which marginal damage estimates will proxy, the proposed measure relies upon market prices, which are then incorporated into a conventional Divisia framework. Data from the electricity generation industry are used to construct both the conventional and newly proposed TFP growth rates. The industry provides an ideal framework within which this growth measure can be tested. It is a large industry that affects a majority of society as it is both consumed as a final good and pervasively used as an intermediate good. The industry is also a large polluter. On an annual basis it has been responsible for approximately one-third of the emissions of carbon-dioxide, one-third of the emissions of nitrous oxides, and two-thirds of the sulfur dioxides emissions, nationally. Furthermore, performance of the proposed measure across various samples was allowed by the diversity of utilities in the industry both with respect to location and fuel mix. Incorporating the value of externalities results in a productivity growth measure which is substantially improved. The difference in calculated productivity gains between the two measures is shown to be sizable under a number of circumstances. As well, the empirical analysis offers some general lessons as to the treatment of various pollutants--it is clearly demonstrated that movement in one pollutant cannot be used to proxy movements in others, or be used as an indicator as to the bias of traditional TFP

  8. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Samea, Renato; Lourenco, Laercio Gomes, E-mail: renatosamea@globo.com [Department of Surgical Oncology of Dr. Arnaldo Vieira de Carvalho Hospital, Sao Paulo, SP (Brazil)

    2011-10-15

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  9. Optimization of externalities using DTM measures: a Pareto optimal multi objective optimization using the evolutionary algorithm SPEA2+

    NARCIS (Netherlands)

    Wismans, Luc; Berkum, van Eric; Bliemer, Michiel; Allkim, T.P.; Arem, van B.

    2748-01-01

    Multi objective optimization of externalities of traffic is performed solving a network design problem in which Dynamic Traffic Management measures are used. The resulting Pareto optimal set is determined by employing the SPEA2+ evolutionary algorithm.

  10. External Beam Radiation Therapy and Abiraterone in Men With Localized Prostate Cancer: Safety and Effect on Tissue Androgens

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eunpi [University of Washington School of Medicine, Seattle, Washington (United States); Fred Hutchinson Cancer Research Center, Seattle, Washington (United States); Mostaghel, Elahe A. [Fred Hutchinson Cancer Research Center, Seattle, Washington (United States); Russell, Kenneth J.; Liao, Jay J.; Konodi, Mark A. [University of Washington School of Medicine, Seattle, Washington (United States); Kurland, Brenda F. [University of Pittsburgh, Pittsburgh, Pennsylvania (United States); Marck, Brett T. [Veterans Affairs Puget Sound Health Care System, Seattle, Washington (United States); Matsumoto, Alvin M. [University of Washington School of Medicine, Seattle, Washington (United States); Veterans Affairs Puget Sound Health Care System, Seattle, Washington (United States); Dalkin, Bruce L. [University of Washington School of Medicine, Seattle, Washington (United States); Montgomery, R. Bruce, E-mail: rbmontgo@uw.edu [University of Washington School of Medicine, Seattle, Washington (United States)

    2015-06-01

    Purpose: Optimizing androgen suppression may provide better control of localized prostate cancer (PCa). Numerous trials have supported the benefit of combining androgen deprivation therapy with definitive radiation therapy in men with locally advanced or high-grade disease. Addition of abiraterone to luteinizing hormone-releasing hormone agonist (LHRHa) with radiation has not been reported. We examined the safety of this combination as well as its impact on androgen suppression. Methods and Materials: A prospective, phase 2 study was conducted in men with localized PCa treated with 6 months of neoadjuvant and concurrent abiraterone with LHRHa and radiation. Duration of adjuvant LHRHa was at the discretion of the treating clinician. Prostate biopsy assays were obtained prior to the start of therapy and prior to radiation. Sera and tissue androgen levels were measured by liquid chromatography-tandem mass spectrometry. Results: A total of 22 men with intermediate- (n=3) and high-risk PCa (n=19) received study therapy. Sixteen men completed the intended course of abiraterone, and 19 men completed planned radiation to 77.4 to 81 Gy. Radiation to pelvic nodes was administered in 20 men. The following grade 3 toxicities were reported: lymphopenia (14 patients), fatigue (1 patient), transaminitis (2 patients), hypertension (2 patients), and hypokalemia (1 patient). There were no grade 4 toxicities. All 21 men who complied with at least 3 months of abiraterone therapy had a preradiation prostate-specific antigen (PSA) concentration nadir of <0.3 ng/mL. Median levels of tissue androgen downstream of CYP17A were significantly suppressed after treatment with abiraterone, and upstream steroids were increased. At median follow-up of 21 months (range: 3-37 months), only 1 patient (who had discontinued abiraterone at 3 months) had biochemical relapse. Conclusions: Addition of abiraterone to LHRHa with radiation is safe and achieves effective prostatic androgen suppression

  11. Calibration for Radiation Protection Equipment for the Measuring Airborne Tritium

    Institute of Scientific and Technical Information of China (English)

    CHEN; Xi-lin; SHEN; En-wei; WEI; Ke-xin; WANG; Kong-zhao; LI; Hou-wen; GE; Jian-an; LV; Xiao-xia

    2012-01-01

    <正>Monitoring airborne tritium is an important routine work in heavy water reactor nuclear power stations and the units related with tritium. Nowadays direct measuring instruments like hand carrying tritium monitors are more often used in routine workshop environment check. Need for calibrating such monitors was suggested. A trial work about the calibration for radiation protection equipment for measuring airborne tritium was carried out with a domestic standard EJ/T 1077-1998 equivalent that of IEC 710.

  12. Measuring the radiation field and radiation hard detectors at JET: Recent developments

    Science.gov (United States)

    Murari, A.; Edlington, T.; Angelone, M.; Bertalot, L.; Bolshakova, I.; Bonheure, G.; Brzozowski, J.; Coccorese, V.; Holyaka, R.; Kiptily, V.; Lengar, I.; Morgan, P.; Pillon, M.; Popovichev, S.; Prior, P.; Prokopowicz, R.; Quercia, A.; Rubel, M.; Santala, M.; Shevelev, A.; Syme, B.; Vagliasindi, G.; Villari, R.; Zoita, V. L.; JET-EFDA Contributors

    2008-08-01

    Since in ITER the radiation field will be much more demanding than that of present day devices, research programmes at JET are aimed at developing radiation hard diagnostics and related components. Initially, significant efforts are devoted to determining the radiation field of both the plasma and in the immediate environment with better accuracy. New developments in MCNP calculations and dedicated measurements provide useful information about the radiation field in the Torus Hall, even during non-operational periods. The effect of using Beryllium in the near future for JET first wall, is being assessed. New materials for activation samples are under consideration and will be tested to improve the calibration accuracy of JET neutron diagnostics. The long-term goal of this work is to obtain spectrometric information from an appropriate combination of different materials. Several studies are under way to modify the radiation field at the detectors by using LiH or pure water as neutron filters, to alleviate the problem of the background in γ-ray measurements. A suite of radiation hard detectors for neutrons, magnetic field and charged particles are being developed. Super-heated fluid neutron detectors, used for yield and imaging, are being upgraded, in order to provide a broad-band spectrometric capability. Chemical vapour deposited diamond diodes are being qualified as counters and as spectrometers. Prototypes of Hall probes made of InSb have been installed on the machine and have provided some preliminary results. Si-on-insulator detectors are under development for use in neutral particle analysers and are currently being bench-tested. Some attention is being devoted to optical components, fibres and mirrors, and to investigating radiation hard electronics using reconfigurable Field Programmable Gate Arrays.

  13. To analyze the impact of intracavitary brachytherapy as boost radiation after external beam radiotherapy in carcinoma of the external auditory canal and middle ear: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Dinesh K Badakh

    2014-01-01

    Conclusion: ICBT as a boost after EBRT has got a positive impact on the OS. In conclusion, our results demonstrate that radical radiation therapy (EBRT and ICBT is the treatment of choice for stage T2, carcinoma of EACMA.

  14. Research on UV radiation measurements and correction methods

    Science.gov (United States)

    Huang, Bo; Dai, Cai-hong; Yu, Jai-lin; Wu, Zhi-feng; Ouyang, Hui-quan

    2011-06-01

    The widely use of UV radiation led to the demand for improved understanding of the properties of instrumentation used to measure this radiation. The UV radiometers are mainly influenced by the factors as operating conditions, environmental conditions and the UV sources to be calibrated and measured. In addition, large errors can occur due to out-of-band, non-linear, and non-ideal cosine or spatial response of the UV meters. Through a new designed measurement system for cosine response property, we do some measuring experiments to 21 kinds of UV radiometers and calculate the relative deviation of each UV meters. The cosine errors are existed universally. It is recommended that keeping the UV source closing to a point source and perpendicular to UV detector when it is measured is very important. We also design and fulfill an experimental system to reflect the measuring errors of UV radiometers when measuring sources and calibrated sources are mismatched. The results show that if the measurement is of a broadband source, it is wise to unify the measuring and calibrated source or the two sources have similar spectral distribution. If that is not possible, we can calculate the spectral mismatch correction factor and spectral matching characteristic factor to correct the measuring data. All the works above are to let the users in appropriate usage of UV Radiometers in a standardized and comparable way and make the measurement quantities more accurate.

  15. Normal tissue tolerance to external beam radiation therapy: Bladder; Dose de tolerance a l'irradiation des tissus sains: la vessie

    Energy Technology Data Exchange (ETDEWEB)

    Pointreau, Y.; Atean, I. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, 37 - Tours (France); Durdux, C. [Universite Paris-Descartes, 75 - Paris (France); Service d' oncologie radiotherapie, hopital europeen Georges-Pompidou, 75 - Paris (France)

    2010-07-15

    The bladder is a hollow visco-elastic organ involved in urinary continence. In relation to its anatomical location, bladder is exposed in whole or in part to ionizing radiation in external radiotherapy or in brachytherapy of the pelvic region. The acute and late functional changes after external beam radiation consist in urinary frequency, compliance defaults and hematuria. Incidence of urinary side-effects, as well as related modalities of radiotherapy, is poorly described in the literature. Medline literature searches were performed via PubMed using the keywords -bladder - radiotherapy - toxicity - radiation cystitis - tolerability - organ at risk- to describe urinary side-effects due to radiation. Some recommendations exist on the dose constraints applied to bladder. These were mainly established from prostate radiation therapy studies but without definitive consensus. In clinical practice, dose constraints take into account clinical settings: bladder cancer which requires total bladder irradiation or others pelvic tumours (prostate, uterus) in which the bladder is considered as an organ at risk. Risks of radiation cystitis increase with total dose (above 60 Gy), bladder irradiated volume and concomitant chemo radiation. Modern techniques using conformal radiotherapy with modulated intensity will probably have beneficial impact on bladder toxicity. (authors)

  16. Measuring electron-positron annihilation radiation from laser plasma interactionsa)

    Science.gov (United States)

    Chen, Hui; Tommasini, R.; Seely, J.; Szabo, C. I.; Feldman, U.; Pereira, N.; Gregori, G.; Falk, K.; Mithen, J.; Murphy, C. D.

    2012-10-01

    We investigated various diagnostic techniques to measure the 511 keV annihilation radiations. These include step-wedge filters, transmission crystal spectroscopy, single-hit CCD detectors, and streaked scintillating detection. While none of the diagnostics recorded conclusive results, the step-wedge filter that is sensitive to the energy range between 100 keV and 700 keV shows a signal around 500 keV that is clearly departing from a pure Bremsstrahlung spectrum and that we ascribe to annihilation radiation.

  17. Measuring electron-positron annihilation radiation from laser plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hui; Tommasini, R. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Seely, J.; Szabo, C. I.; Feldman, U.; Pereira, N. [Artep Inc., Ellicott City, Maryland 21042 (United States); Gregori, G.; Falk, K.; Mithen, J.; Murphy, C. D. [Clarendon Laboratory, University of Oxford, Oxford OX1 3PU (United Kingdom)

    2012-10-15

    We investigated various diagnostic techniques to measure the 511 keV annihilation radiations. These include step-wedge filters, transmission crystal spectroscopy, single-hit CCD detectors, and streaked scintillating detection. While none of the diagnostics recorded conclusive results, the step-wedge filter that is sensitive to the energy range between 100 keV and 700 keV shows a signal around 500 keV that is clearly departing from a pure Bremsstrahlung spectrum and that we ascribe to annihilation radiation.

  18. A Comparison of EAST Shock-Tube Radiation Measurements with a New Air Radiation Model

    Science.gov (United States)

    Johnston, Christopher O.

    2008-01-01

    This paper presents a comparison between the recent EAST shock tube radiation measurements (Grinstead et al., AIAA 2008-1244) and the HARA radiation model. The equilibrium and nonequilibrium radiation measurements are studied for conditions relevant to lunar-return shock-layers; specifically shock velocities ranging from 9 to 11 kilometers per second at initial pressures of 0.1 and 0.3 Torr. The simulated shock-tube flow is assumed one-dimensional and is calculated using the LAURA code, while a detailed nonequilibrium radiation prediction is obtained in an uncoupled manner from the HARA code. The measured and predicted intensities are separated into several spectral ranges to isolate significant spectral features, mainly strong atomic line multiplets. The equations and physical data required for the prediction of these strong atomic lines are reviewed and their uncertainties identified. The 700-1020 nm wavelength range, which accounts for roughly 30% of the radiative flux to a peak-heating lunar return shock-layer, is studied in detail and the measurements and predictions are shown to agree within 15% in equilibrium. The plus or minus 1.5% uncertainty on the measured shock velocity is shown to cause up to a plus or minus 30% difference in the predicted radiation. This band of predictions contains the measured values in almost all cases. For the highly nonequilibrium 0.1 Torr cases, the nonequilibrium radiation peaks are under-predicted by about half. This under-prediction is considered acceptable when compared to the order-of-magnitude over-prediction obtained using a Boltzmann population of electronic states. The reasonable comparison in the nonequilibrium regions provides validation for both the non-Boltzmann modeling in HARA and the thermochemical nonequilibrium modeling in LAURA. The N2 (+)(1-) and N2(2+) molecular band systems are studied in the 290 480 nm wavelength range for both equilibrium and nonequilibrium regimes. The non-Boltzmann rate models for these

  19. Measurement of parameters in Indus-2 synchrotron radiation source.

    Science.gov (United States)

    Ghodke, A D; Husain, Riyasat; Kumar, Pradeep; Yadav, Surendra; Puntambekar, T A

    2012-10-01

    The paper presents the measurement of optics parameters in Indus-2 synchrotron radiation source, which include betatron tune, beta function, dispersion function, natural chromaticity, corrected chromaticity, central RF frequency, momentum compaction factor, and linear betatron coupling. Two methods were used for beta function measurement; a conventional quadrupole scan method and a method using the fitting of the orbit response matrix. A robust Levenberg-Marquardt algorithm was used for nonlinear least square fitting of the orbit response matrix. In this paper, detailed methods for the parameter measurements are described. The measured results are discussed and compared with the theoretical values obtained using accelerator simulation code Accelerator Toolbox in MATLAB.

  20. Recent measurements for hadrontherapy and space radiation: nuclear physics.

    Science.gov (United States)

    Miller, J

    2001-01-01

    The particles and energies commonly used for hadron therapy overlap the low end of the charge and energy range of greatest interest for space radiation applications, Z=1-26 and approximately 100-1000 MeV/nucleon. It has been known for some time that the nuclear interactions of the incident ions must be taken into account both in treatment planning and in understanding and addressing the effects of galactic cosmic ray ions on humans in space. Until relatively recently, most of the studies of nuclear fragmentation and transport in matter were driven by the interests of the nuclear physics and later, the hadron therapy communities. However, the experimental and theoretical methods and the accelerator facilities developed for use in heavy ion nuclear physics are directly applicable to radiotherapy and space radiation studies. I will briefly review relevant data taken recently at various accelerators, and discuss the implications of the measurements for radiotherapy, radiobiology and space radiation research.

  1. Recent measurements for hadrontherapy and space radiation: nuclear physics

    Science.gov (United States)

    Miller, J.

    2001-01-01

    The particles and energies commonly used for hadron therapy overlap the low end of the charge and energy range of greatest interest for space radiation applications, Z=1-26 and approximately 100-1000 MeV/nucleon. It has been known for some time that the nuclear interactions of the incident ions must be taken into account both in treatment planning and in understanding and addressing the effects of galactic cosmic ray ions on humans in space. Until relatively recently, most of the studies of nuclear fragmentation and transport in matter were driven by the interests of the nuclear physics and later, the hadron therapy communities. However, the experimental and theoretical methods and the accelerator facilities developed for use in heavy ion nuclear physics are directly applicable to radiotherapy and space radiation studies. I will briefly review relevant data taken recently at various accelerators, and discuss the implications of the measurements for radiotherapy, radiobiology and space radiation research.

  2. Simulation study of enhancing laser driven multi-keV line-radiation through application of external magnetic fields

    Science.gov (United States)

    Kemp, G. E.; Colvin, J. D.; Blue, B. E.; Fournier, K. B.

    2016-10-01

    We present a path forward for enhancing laser driven, multi-keV line-radiation from mid- to high-Z, sub-quarter-critical density, non-equilibrium plasmas through inhibited thermal transport in the presence of an externally generated magnetic field. Preliminary simulations with Kr and Ag suggest that as much as 50%-100% increases in peak electron temperatures are possible—without any changes in laser drive conditions—with magnetized interactions. The increase in temperature results in ˜2 -3 × enhancements in laser-to-x-ray conversion efficiency for K-shell emission with simultaneous ≲ 4 × reduction in L-shell emission using current field generation capabilities on the Omega laser and near-term capabilities on the National Ignition Facility laser. Increased plasma temperatures and enhanced K-shell emission are observed to come at the cost of degraded volumetric heating. Such enhancements in high-photon-energy x-ray sources could expand the existing laser platforms for increasingly penetrating x-ray radiography.

  3. Long-term Symptoms after External Beam Radiation Therapy for Prostate Cancer with Three or Four Fields

    Energy Technology Data Exchange (ETDEWEB)

    Al-Abany, Massoud; Helgason, Asgeir R.; Aagren-Cronqvist, Anna-Karin; Svensson, Christer; Wersaell, Peter; Steineck, Gunnar [Karolinska Inst., Stockholm (Sweden). Dept. of Oncology-Pathology

    2002-10-01

    The aim of this study was to investigate whether external beam radiation treatment with three or four fields affects the risk of long-term distressful symptoms. The study included 145 patients who had been treated in Stockholm from 1993 to 1996 for localized prostate cancer. Bowel, urinary and sexual function as well as symptom-induced distress were assessed by means of a postal questionnaire 29-59 months after therapy. Among patients treated with a multileaf collimator, defecation urgency, diarrhoea and loose stools were more common after four fields than after three fields, but faecal leakage necessitating the use of pads and distress from the gastrointestinal tract were less common (although not statistically significantly so). Among bowel symptoms, the strongest association with gastrointestinal distress was found for faecal leakage. Three fields without a multileaf collimator entailed a higher risk of defecation urgency than three fields with a multileaf collimator. We conclude that the choice of three or four fields may imply a contrasting risk scenario for defecation urgency or diarrhoea in comparison with faecal leakage.

  4. Half-brightness measurements of candidate radiation sensors

    Science.gov (United States)

    Williams, Stephen Alexander

    Ionizing radiation poses a significant challenge for human and robotic space missions. Practical luminescent sensors will depend heavily upon research investigating the resistance of these materials to ionizing radiation and the ability to anneal or self-heal the damage caused by such radiation. In 1951, Birks and Black experimentally showed that the luminescent efficiency of anthracene bombarded by alpha particles varies with total fluence. From 1990 to the present, we found that the Birks and Black relation describes the reduction in light emission yield for every tested luminescent material except lead phosphate glass due to proton irradiation. These results indicate that radiation produced quenching centers compete with emission for absorbed energy. The purpose of this thesis is to present new results from related luminescent materials by exposing them to a 1-3 MeV proton beam. Particular emphasis will be placed on recent measurements made with bright luminescent materials, such as zinc sulfide doped with manganese (ZnS:Mn), europium tetrakis dibenzoylmethide triethylammonium (EuD4TEA), an magnesium tetrakis dibenzoylmethide triethylammonium (MgD4TEA). This research can be used to help determine if luminescent materials can be used as a real-time sensor to detect ionizing radiation.

  5. 基于太阳辐射模拟的外遮阳优化设计%Design optimization of external sunshade based on solar radiation simulation

    Institute of Scientific and Technical Information of China (English)

    杨晓龙

    2014-01-01

    To solve the problem on external sunshade design under the situation of complex configuration and orientation,solar radiation simula-tion is used to analyze the shelter effect of different types of external sunshade. The facades whose shelter effect is poor with fixed external sun-shade turn to use adjustable external sunshade,making the balance between energy saving rate and economy.%为解决在这种复杂建筑体型和朝向条件下的外遮阳优化,通过夏季太阳辐射量模拟分析了不同遮阳形式的遮阳效果,指出选择固定外遮阳效果不佳的立面采用可调节外遮阳,达到了节能率和经济性兼顾的效果。

  6. Measurement of Radiation Belt Partcles by MDS-1 Onboard SEDA

    Science.gov (United States)

    Matsumoto, H.; Koshiishi, H.; Goka, T.

    The Space Environment Data Acquisition Equipment (SEDA) is on board the Mission Demonstration Test Satellite-1 (MDS-1) to measure the radiation environment, which was launched into geo-stationary transfer orbit (GTO) on February 4, 2002 with an apogee of about 35,700km, a perigee of about 500 km and an inclination of about 28.5 degrees. SEDA consists of the four instruments. Standard Dose Monitor monitors the electron and proton flux. Dosimeter measures the integrated radiation dose at fifty-six points of the satellite. Heavy Ion Telescope monitors the flux of heavy ions from He to Fe. Magnetometer measures the magnetic field in the magnetosphere. In this paper are described first results and comparison with the ISO standard model for the space environment

  7. Assessment and comparison of methods for solar ultraviolet radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Leszczynski, K.

    1995-06-01

    In the study, the different methods to measure the solar ultraviolet radiation are compared. The methods included are spectroradiometric, erythemally weighted broadband and multi-channel measurements. The comparison of the different methods is based on a literature review and assessments of optical characteristics of the spectroradiometer Optronic 742 of the Finnish Centre for Radiation and Nuclear Safety (STUK) and of the erythemally weighted Robertson-Berger type broadband radiometers Solar Light models 500 and 501 of the Finnish Meteorological Institute and STUK. An introduction to the sources of error in solar UV measurements, to methods for radiometric characterization of UV radiometers together with methods for error reduction are presented. Reviews on experiences from world-wide UV monitoring efforts and instrumentation as well as on the results from international UV radiometer intercomparisons are also presented. (62 refs.).

  8. Skin perfusion pressure on the legs measured as the external pressure required for skin reddening after blanching

    DEFF Research Database (Denmark)

    Holstein, P; Nielsen, P.E.; Lund, P

    1980-01-01

    Hg (SD 8.7). As compared to the intra-arterial blood pressure the BTEP was found to lie close to the mean blood pressure in normal subjects as well as in hypertensive subjects. The present data indicate that the skin perfusion pressure on the legs can be measured by the rapid photo-electric technique......The skin perfusion on the calf was measured photo-electrically and by isotope washout technique using external counter pressure by a blood pressure cuff. By the photocell the skin blanching threshold external pressure (BTEP) was recorded on histamine flared red skin. By isotope washout technique...... the skin blood flow cessation external pressure (FCEP) was recorded using intra-dermal [131I-]-antipyrine mixed with histamine in estimating the skin blood flow. The external pressure was measured with an airfilled plastic cushion connected to a mercury manometer. Over a wide range of pressures as obtained...

  9. Accounting for External Turbulence of Logistics Organizations via Performance Measurement Systems

    DEFF Research Database (Denmark)

    Bühler, Andreas; Wallenburg, Carl Marcus; Wieland, Andreas

    2016-01-01

    Purpose: This paper aims to investigate the role of upper management in designing performance measurement systems (PMS) that account for external turbulence of the organization and to show how this PMS design for turbulence impacts organizational resilience and distribution service performance...... distribution service performance. Originality/value: This paper is the first to introduce the concept of PMS design for turbulence to the literature and to show that it is relevant for supply chain risk management by fostering the capabilities and the performance of logistics organizations. Further....... Design/methodology/approach: Hypotheses are developed by integrating management accounting and strategic management perspectives into supply chain management and subsequently tested based on data from 431 logistics organizations (i.e. both logistics companies and internal logistics departments...

  10. Measurement of LINAC 90 degrees head leakage radiation TVL values.

    Science.gov (United States)

    Li, Zuofeng; Mutic, Sasa; Low, Daniel

    2006-09-01

    One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head leakage radiation of medical linear accelerators can be technically challenging due to the low dose rate causing poor signal-to-noise ratios in most detectors. 90 degrees leakage tenth-value layer (TVL) values in concrete have not been reported for the Elekta linear accelerators. This report describes our measurements of 90 degrees leakage TVL values for 6, 10, and 18 MV x-ray beams for an Elekta Precise Treatment System. A large-volume (1000 cm3) unpressurized ionization chamber and a high sensitivity electrometer, together with a separate chamber bias power supply, were used in these measurements in order to maximize the signal-to-noise ratio. A lead enclosure, of minimum thickness 10 cm, was constructed inside the treatment room to house the ion chamber to reduce the influence of room-scattered radiation. A square aperture of 10 X 10 cm2 area was left in the shield and aimed towards the accelerator head. Measurements were performed with the chamber placed at approximately 2 m from the accelerator isocenter. Concrete slabs with individual dimensions of approximately 40 X 40 cm2 cross-sectional area and 5 cm thickness were placed between the accelerator head and the ion chamber for these measurements. The measurements were performed with total concrete thickness of up to 80 cm, so that values up to the third TVL were measured. These measurements showed thatthe first concrete TVL values are 22, 23, and 28 cm (8.6, 9.1, and 10.5 in.) for 6, 10, and 18 MV beams, while the average of the first 3 TVL's were 25, 26, and 29 cm (9.9, 10.2, and 11.5 in.). Measured values agreed to within 10% of previously reported values for Varian linear accelerators for

  11. Measurements of knee rotation-reliability of an external device in vivo

    Directory of Open Access Journals (Sweden)

    Almquist Per O

    2011-12-01

    Full Text Available Abstract Background Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA. The aim of this study was to investigate the reliability of the device. Method The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient 2,1 (ICC 2,1, 95% confidence interval (CI of ICC and 95% CI between test trials and examiners were used as statistical tests. Result ICC2,1 ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. Conclusion The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30° with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.

  12. Direct measurements of radiative capture reactions with DRAGON

    Science.gov (United States)

    Christian, Gregory

    2015-10-01

    Direct measurements of radiative proton and alpha capture reactions are crucial for understanding nucleosynthesis in a variety of astrophysical environments, including classical novae, supernovae, X-Ray bursts, and quiescent stellar burning. Often the most important reactions have very low cross sections or involve unstable targets, making laboratory measurements extremely challenging. The detector of recoils and gammas of nuclear reactions (DRAGON) at TRIUMF is a recoil mass separator designed to measure radiative capture reactions in inverse kinematics, with beam suppression factors as high as 1016. When combined with the intense radioactive beams available at the ISAC-I facility, DRAGON's capabilities are unique and world-leading. In this talk, I will give a brief technical overview of DRAGON before presenting results from recent experiments. Some highlights include the first-ever direct measurement of 38K(p , γ) 39Ca, a crucial reaction for determining the endpoint of nova nucleosynthesis, and measurements of 76Se(α , γ) 80Kr. The latter measurements determine the rate of the reverse reaction, 80Kr(γ , α) 76Se, an important waiting point in the synthesis of the p-nuclei. I will also discuss future (and ongoing) developments at DRAGON, including the commissioning of a new chamber for high-precision elastic scattering measurements and plans to determine the 330 keV resonance strength in 18F(p , γ) 19Ne via measurements of 15O(α , γ) 19Ne and 15O + α elastic scattering.

  13. Measurements of radiated elastic wave energy from dynamic tensile cracks

    Science.gov (United States)

    Boler, Frances M.

    1990-01-01

    The role of fracture-velocity, microstructure, and fracture-energy barriers in elastic wave radiation during a dynamic fracture was investigated in experiments in which dynamic tensile cracks of two fracture cofigurations of double cantilever beam geometry were propagating in glass samples. The first, referred to as primary fracture, consisted of fractures of intact glass specimens; the second configuration, referred to as secondary fracture, consisted of a refracture of primary fracture specimens which were rebonded with an intermittent pattern of adhesive to produce variations in fracture surface energy along the crack path. For primary fracture cases, measurable elastic waves were generated in 31 percent of the 16 fracture events observed; the condition for radiation of measurable waves appears to be a local abrupt change in the fracture path direction, such as occurs when the fracture intersects a surface flaw. For secondary fractures, 100 percent of events showed measurable elastic waves; in these fractures, the ratio of radiated elastic wave energy in the measured component to fracture surface energy was 10 times greater than for primary fracture.

  14. Optical radiation measurements for photovoltaic applications: instrumentation uncertainty and performance

    Science.gov (United States)

    Myers, Daryl R.; Reda, Ibrahim; Wilcox, Stephen; Andreas, Afshin

    2004-11-01

    Evaluating the performance of photovoltaic (PV) devices in the laboratory and in the field requires accurate knowledge of the optical radiation stimulating the devices. We briefly describe the radiometric instrumentation used for characterizing broadband and spectral irradiance for PV applications. Spectral radiometric measurement systems are used to characterize solar simulators (continuous and pulsed, or flash sources) and natural sunlight. Broadband radiometers (pyranometers and pyrheliometers) are used to assess solar resources for renewable applications and develop and validate broadband solar radiation models for estimating system performance. We describe the sources and magnitudes of uncertainty associated with calibrations and measuremens using these instruments. The basic calibration and measurement uncertainty associated with this instrumentaion are based on the guidlines described in the International Standards Organization (ISO) and Bureau INternationale des Poids et Mesures (BIPM) Guide to Uncertainty in Measurement. The additional contributions to uncertainty arising from the uncertainty in characterization functions and correction schemes are discussed and ilustrated. Finally, empirical comparisons of several solar radiometer instrumentation sets illustrate that the best measurement accuracy for broadband radiation is on the order of 3%, and spectrally dependent uncertainty for spectroradiometer systems range from 4% in the visible to 8% to 10% in the ultraviolet and infrared.

  15. 10 CFR Appendix Z to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of External Power Supplies

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix Z to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of External Power Supplies 1. Scope: This appendix covers the test requirements used to measure energy consumption...

  16. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  17. Influence of external inputs and asymmetry of connections on information-geometric measures involving up to ten neuronal interactions.

    Science.gov (United States)

    Nie, Yimin; Fellous, Jean-Marc; Tatsuno, Masami

    2014-10-01

    The investigation of neural interactions is crucial for understanding information processing in the brain. Recently an analysis method based on information geometry (IG) has gained increased attention, and the property of the pairwise IG measure has been studied extensively in relation to the two-neuron interaction. However, little is known about the property of IG measures involving more neuronal interactions. In this study, we systematically investigated the influence of external inputs and the asymmetry of connections on the IG measures in cases ranging from 1-neuron to 10-neuron interactions. First, the analytical relationship between the IG measures and external inputs was derived for a network of 10 neurons with uniform connections. Our results confirmed that the single and pairwise IG measures were good estimators of the mean background input and of the sum of the connection weights, respectively. For the IG measures involving 3 to 10 neuronal interactions, we found that the influence of external inputs was highly nonlinear. Second, by computer simulation, we extended our analytical results to asymmetric connections. For a network of 10 neurons, the simulation showed that the behavior of the IG measures in relation to external inputs was similar to the analytical solution obtained for a uniformly connected network. When the network size was increased to 1000 neurons, the influence of external inputs almost disappeared. This result suggests that all IG measures from 1-neuron to 10-neuron interactions are robust against the influence of external inputs. In addition, we investigated how the strength of asymmetry influenced the IG measures. Computer simulation of a 1000-neuron network showed that all the IG measures were robust against the modulation of the asymmetry of connections. Our results provide further support for an information-geometric approach and will provide useful insights when these IG measures are applied to real experimental spike data.

  18. Radiation protection: Radiation dose units and fundamentals. Correct use of radiation dose units, measurements, risk assessment; Dosisbegriffe und Grundlagen im Strahlenschutz. Dosisbegriffe richtig anwenden, Messgroessen bestimmen, Risiken bewerten

    Energy Technology Data Exchange (ETDEWEB)

    Folkerts, K.H.; Wolf, H.

    2005-07-01

    Radiation protection intends to prevent radiation damage by appropriate staff-related and technical measures in accordance with the specifications of the German X-Ray Ordinance (RoV) and Radiation Protection Ordinance (StrlSchV) and in agreement with the ICRLP (International Commission on Radiological Protection). They require that radiation use must be justified, exposure conditions must be optimised, and exposure times must be limited to the shortest time necessary. In practical use, this requires considerable practical and theoretical knowledge from the user concerning the physical properties of radiation sources, interactions with tissue and matter of different types of radiation, and biological effects of radiation. National and international organizations and committees have specified the knowledge which a user must have as follows: Physical fundamentals of radiation protection; Measuring quantities and specified standard units; Organisational and constructional radiation protection; Legal knowledge. (orig.)

  19. Atmospheric Radiation Measurement Program Facilities Newsletter - September 1999

    Energy Technology Data Exchange (ETDEWEB)

    Holdridge, D. J., ed

    1999-09-27

    The Atmospheric Radiation Measurement Program September 1999 Facilities Newsletter discusses the several Intensive Observation Periods (IOPs) that the ARM SGP CART site will host in the near future. Two projects of note are the International Pyrgeometer Intercomparison and the Fall Single Column Model (SCM)/Nocturnal Boundary Layer (NBL) IOP. Both projects will bring many US and international scientists to the SGP CART site to participate in atmospheric research.

  20. Radio Frequency Radiation (RFR) Measurements in Operational Settings.

    Science.gov (United States)

    1984-12-01

    1NURAT0 OF -HSAG Deport No. 84-028CV111ARA USAF OCCUPATIONAL AND ENVIRONMENTAL HEALTH LABORATORY Brooks AFB, Texas 78235 RADIO FREQUENCY RADIATION (RFR...with a 60 Watt/cm3 peak power burnout rating. First attempts to use these early instruments (Model 8300). in the investigation of an alleged...an aside, Narda also makes several other probe series for measurements to as low as 300 Kiz. All Narda probes are susceptible to burnout when exposed

  1. Coherent radiation spectrum measurements at KEK LUCX facility

    Energy Technology Data Exchange (ETDEWEB)

    Shevelev, M., E-mail: mishe@post.kek.jp [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Aryshev, A., E-mail: alar@post.kek.jp [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Araki, S.; Fukuda, M. [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Karataev, P. [John Adams Institute at Royal Holloway, University of London, Egham, Surrey TW20 0EX (United Kingdom); Terunuma, N.; Urakawa, J. [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2015-01-21

    This paper demonstrates the detailed design concept, alignment, and initial testing of a Michelson interferometer for the THz spectral range. We present the first results on the measurement of a coherent transition radiation spectrum and describe the performance of a pair of ultra-fast broadband room temperature Schottky barrier diode detectors. We discuss the main criteria of interferometer beam splitter optimization, the alignment technique, the high-precision calibration and linearity check of the motion system.

  2. Characterization of a radiation detector for aircraft measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holanda M, L. de; Federico, C. A.; Caldas, L. V. E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares, Av. Lineu Prestes 2242, Cidade Universitaria, CEP 05508-000, Sao Paulo (Brazil)

    2014-08-15

    Air crews, as pilots and flight attendants, are subjected to cosmic ray doses which can be higher than the average doses on workers from the nuclear industry. The diversity of particles of high energies present in the radiation field on board of air crafts turns the determination of the incident dose difficult, and requires special care regarding dosimetric systems to be used in this kind of radiation field. The Brazilian Air Force, through its Institute for Advanced Studies (Instituto de Estudos Avancados, IEAv/DCTA) in conjunction with the Institute of Energetic and Nuclear Research (Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP) are working on this subject since 2008. A prototype of a radiation detector for aircraft measurements was previously built and tested in flight and laboratory conditions. The detector is able of measuring a quantity known as absorbed dose (using passive dosimeters), which will subsequently be correlated to the ambient dose equivalent and the effective dose received by air crews. In this context, a theoretical approach through Monte Carlo simulations with the computational codes MCNP5 and MCNPX was used to model and characterize the detector response at such experimental conditions. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between the absorbed doses measured and simulated, and its relationship with the ambient dose equivalent and the effective dose for this detector. (author)

  3. Comparative Measurements of Cosmic Radiation Monitors for Aircrew Exposure Assessment

    Science.gov (United States)

    Getley, I. L.; Bennett, L. G. I.; Boudreau, M. L.; Lewis, B. J.; Green, A. R.; Butler, A.; Takada, M.; Nakamura, T.

    Various commercially available electronic personal dosimeters (EPDs) have recently been flown on numerous scheduled airline flights in order to determine their viability as small, convenient monitors to measure cosmic radiation at altitude. Often, frequent flyers or airline crew will acquire such dosimeters and report the readings from their flights, without due regard for the mixed radiation field at altitude, which is different from the intended fields on land. A sampling of EPDs has been compared to two types of spectrometers, which measure the total radiation spectrum. The "HAWK" tissue equivalent proportional counter is considered a reference instrument and measures the total dose equivalent H*(10). The Liulin-4N and 4SN linear energy transfer spectrometers each have a silicon semiconductor-based PIN diode detector which provides an absorbed dose, D, but have been further developed to provide H*(10). A Thermo Electron FH41B and B-10, and EPD-N2, and several personal dosimeters (Fuji NRY-21 and NRF-20, and RADOS DIS-100) were also flown.

  4. Comparative Measurements of Cosmic Radiation Monitors for Aircrew Exposure Assessment

    Science.gov (United States)

    Getley, I. L.; Bennett, L. G. I.; Boudreau, M. L.; Lewis, B. J.; Green, A. R.; Butler, A.; Takada, M.; Nakamura, T.

    Various commercially available electronic personal dosimeters (EPDs) have recently been flown on numerous scheduled airline flights in order to determine their viability as small, convenient monitors to measure cosmic radiation at altitude. Often, frequent flyers or airline crew will acquire such dosimeters and report the readings from their flights, without due regard for the mixed radiation field at altitude, which is different from the intended fields on land. A sampling of EPDs has been compared to two types of spectrometers, which measure the total radiation spectrum. The “HAWK” tissue equivalent proportional counter is considered a reference instrument and measures the total dose equivalent H * (10). The Liulin-4N and 4SN linear energy transfer spectrometers each have a silicon semiconductor-based PIN diode detector which provides an absorbed dose, D, but have been further developed to provide H * (10). A Thermo Electron FH41B and B-10, and EPD-N2, and several personal dosimeters (Fuji NRY-21 and NRF-20, and RADOS DIS-100) were also flown.

  5. Investigation of Radiation Protection Methodologies for Radiation Therapy Shielding Using Monte Carlo Simulation and Measurement

    Science.gov (United States)

    Tanny, Sean

    The advent of high-energy linear accelerators for dedicated medical use in the 1950's by Henry Kaplan and the Stanford University physics department began a revolution in radiation oncology. Today, linear accelerators are the standard of care for modern radiation therapy and can generate high-energy beams that can produce tens of Gy per minute at isocenter. This creates a need for a large amount of shielding material to properly protect members of the public and hospital staff. Standardized vault designs and guidance on shielding properties of various materials are provided by the National Council on Radiation Protection (NCRP) Report 151. However, physicists are seeking ways to minimize the footprint and volume of shielding material needed which leads to the use of non-standard vault configurations and less-studied materials, such as high-density concrete. The University of Toledo Dana Cancer Center has utilized both of these methods to minimize the cost and spatial footprint of the requisite radiation shielding. To ensure a safe work environment, computer simulations were performed to verify the attenuation properties and shielding workloads produced by a variety of situations where standard recommendations and guidance documents were insufficient. This project studies two areas of concern that are not addressed by NCRP 151, the radiation shielding workload for the vault door with a non-standard design, and the attenuation properties of high-density concrete for both photon and neutron radiation. Simulations have been performed using a Monte-Carlo code produced by the Los Alamos National Lab (LANL), Monte Carlo Neutrons, Photons 5 (MCNP5). Measurements have been performed using a shielding test port designed into the maze of the Varian Edge treatment vault.

  6. Cost-effectiveness of radiotherapy during surgery compared with external radiation therapy in the treatment of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Hedie Mosalanezhad

    2016-04-01

    Full Text Available Introduction: Intraoperative radiation therapy device (IORT is one of the several options for partial breast irradiation. IORT is sent to the tumor bed during surgery and can be replaced with conventional standard therapy (EBRT. The aim of this study was to evaluate the safety and effectiveness of IORT machine compared with EBRT and to determine the dominant option in terms of the cost-effectiveness. Method: This study was conducted in two phases; the first phase was a comprehensive review of the electronic databases search that was extracted after extraction and selection of the articles used in this article on effectiveness outcomes. Data collection form was completed by professionals and experts to estimate the cost of treatment, intraoperative radiotherapy and radiotherapy cost when using external radiation therapy process; direct costs were considered from the perspective of service provider and they were calculated in the second phase to determine the option of cost-effective ICER. Excel software was used for data analysis and sensitivity analysis was performed to determine the strength of the results of cost-effectiveness. Results:18 studies were selected but only 8 of them were shown to have acceptable quality. The consequences like “rate of cancer recurrence”, “seroma”, “necrosis”, “toxic”, “skin disorders and delayed wound healing” and “spread the pain” were among the consequences used in the selected articles. The total costs for each patient during a course of treatment for EBRT and IORT were estimated 1398 and $5337.5, respectively. During the analysis, cost-effectiveness of the consequences of cancer recurrence, seroma, necrosis and skin disorders and delayed wound healing ICER was calculated. And IORT was found to be the dominant supplier in all cases. Also, in terms of implications of toxicity and prevalence of pain, IORT had a lower cost and better effectiveness and consequently the result was more cost

  7. Theory and measurement of emittance properties for radiation thermometry applications.

    Science.gov (United States)

    Dewitt, D. P.; Hernicz, R. S.

    1972-01-01

    Some basic concepts of radiation physics are briefly reviewed to provide an introduction to the radiative properties - including emittance, reflectance, absorptance, and transmittance - their definitions, interrelations, theory and methods of measurement. Analyzed data showing typical characteristics of temperature and wavelength dependence, surface effects and environmental influences on the radiation properties of selected classes of materials are presented. Emphasis is placed on those emittance properties of particular interest to conventional radiation thermometry applications, but sufficient generality on all properties is presented to be useful for new or unusual techniques where a more detailed understanding of the behavior of materials is desirable. Data sources are identified to assist the reader in locating property information. It is the intention of the paper to give the reader a background to become more fully aware of the pitfalls, limitations, but of course, advantages in the use of data from the literature. The paper is written in the form of an abbreviated review fully documenting the more important topics and concepts which can only be treated briefly.

  8. Measuring solar UV radiation with EBT radiochromic film.

    Science.gov (United States)

    Butson, Ethan T; Cheung, Tsang; Yu, Peter K N; Butson, Martin J

    2010-10-21

    Ultraviolet radiation dosimetry has been performed with the use of a radiochromic film dosimeter called Gafchromic EBT for solar radiation exposure. The film changes from a clear colour to blue colour when exposed to ultraviolet radiation and results have shown that the colour change is reproducible within ±10% at 5 kJ m(-2) UV exposure under various conditions of solar radiation. Parameters tested included changes in season (summer versus winter exposure), time of day, as well as sky conditions such as cloudy skies versus clear skies. As the radiochromic films' permanent colour change occurs in the visible wavelengths the film can be analysed with a desktop scanner with the most sensitive channel for analysis being the red component of the signal. Results showed that an exposure of 5 kJ m(-2) (approximately 1 h exposure in full sun during summer) produced an approximate 0.28 change in the net OD when analysed in reflection mode on the desktop scanner which is significant darkening. The main advantages of this film type, and thus the new EBT2 film which has replaced EBT for measurement of UV exposure, is the visible colour change and thus easy analysis using a desktop scanner, its uniformity in response and its robust physical strength for use in outside exposure situations.

  9. A survey of techniques to reduce and manage external beam radiation-induced xerostomia in British oncology and radiotherapy departments

    Energy Technology Data Exchange (ETDEWEB)

    Macknelly, Andrew [Norfolk and Norwich University Hospital (United Kingdom); Day, Jane [Faculty of Health, Wellbeing and Science, University Campus Suffolk, Waterfront Building, Neptune Quay, Ipswich (United Kingdom)], E-mail: j.day@ucs.ac.uk

    2009-11-15

    Xerostomia is the most common side effect of external beam radiotherapy to the head and neck [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et-al. Can dose reduction to one parotid gland prevent xerostomia? - A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy. Clinical Oncology 2006;18(6):497-504.]. A survey was carried out in British oncology departments to determine what treatment regimes, to minimise xerostomia, are used for patients with head-and-neck cancers treated with external beam radiotherapy. A semi-structured questionnaire consisting of both quantitative and qualitative questions was designed that asked departments which of the identified methods they used, why a method might not be currently employed, and whether its use had ever been considered. The study found that there are wide disparities between the techniques employed by oncology departments to avoid and reduce xerostomia in patients with cancers of the head and neck. The National Institute of Clinical Health and Excellence, [National Institute for Clinical Health and Excellence (NICE). Improving outcomes in head and neck cancers: the manual. London: Office of Public Sector Information; 2004.] for example, recommends that patients are given dental care and dietary advice but some departments did not appear to be doing this. Less than half of departments stated that they offer complementary therapies and less than 40% prescribed pilocarpine, a saliva-stimulant. Only two respondents stated that they use amifostine, a radioprotector, during radiotherapy treatment to the head and neck. The results also suggested a move toward using Intensity Modulated Radiotherapy (IMRT) for treating head-and-neck cancers which offers better normal tissue sparing than three-dimensional conformal radiotherapy. [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et al. Can dose reduction to one parotid gland prevent xerostomia

  10. Prognostic Utility of Cell Cycle Progression Score in Men With Prostate Cancer After Primary External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Freedland, Stephen J., E-mail: steve.freedland@duke.edu [Department of Surgery, Durham VA Medical Center, Durham, North Carolina (United States); Department of Surgery (Urology), Duke University School of Medicine, Durham, North Carolina (United States); Department of Pathology, Duke University School of Medicine, Durham, North Carolina (United States); Gerber, Leah [Department of Surgery, Durham VA Medical Center, Durham, North Carolina (United States); Department of Surgery (Urology), Duke University School of Medicine, Durham, North Carolina (United States); Department of Pathology, Duke University School of Medicine, Durham, North Carolina (United States); Reid, Julia; Welbourn, William; Tikishvili, Eliso; Park, Jimmy; Younus, Adib; Gutin, Alexander; Sangale, Zaina; Lanchbury, Jerry S. [Myriad Genetics, Inc, Salt Lake City, Utah (United States); Salama, Joseph K. [Department of Radiation Oncology, Durham VA Medical Center, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University School of Medicine, Durham, North Carolina (United States); Stone, Steven [Myriad Genetics, Inc, Salt Lake City, Utah (United States)

    2013-08-01

    Purpose: To evaluate the prognostic utility of the cell cycle progression (CCP) score, a RNA signature based on the average expression level of 31 CCP genes, for predicting biochemical recurrence (BCR) in men with prostate cancer treated with external beam radiation therapy (EBRT) as their primary curative therapy. Methods and Materials: The CCP score was derived retrospectively from diagnostic biopsy specimens of men diagnosed with prostate cancer from 1991 to 2006 (n=141). All patients were treated with definitive EBRT; approximately half of the cohort was African American. Outcome was time from EBRT to BCR using the Phoenix definition. Median follow-up for patients without BCR was 4.8 years. Association with outcome was evaluated by Cox proportional hazards survival analysis and likelihood ratio tests. Results: Of 141 patients, 19 (13%) had BCR. The median CCP score for patient samples was 0.12. In univariable analysis, CCP score significantly predicted BCR (P=.0017). The hazard ratio for BCR was 2.55 for 1-unit increase in CCP score (equivalent to a doubling of gene expression). In a multivariable analysis that included Gleason score, prostate-specific antigen, percent positive cores, and androgen deprivation therapy, the hazard ratio for CCP changed only marginally and remained significant (P=.034), indicating that CCP provides prognostic information that is not provided by standard clinical parameters. With 10-year censoring, the CCP score was associated with prostate cancer-specific mortality (P=.013). There was no evidence for interaction between CCP and any clinical variable, including ethnicity. Conclusions: Among men treated with EBRT, the CCP score significantly predicted outcome and provided greater prognostic information than was available with clinical parameters. If validated in a larger cohort, CCP score could identify high-risk men undergoing EBRT who may need more aggressive therapy.

  11. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  12. Measurements of prompt radiation induced conductivity in Teflon (PTFE).

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, E. Frederick; Zarick, Thomas Andrew; Sheridan, Timothy J.; Preston, E. [ITT Exelis Mission Systems, Colorado Springs, CO

    2013-05-01

    We performed measurements of the prompt radiation induced conductivity (RIC) in thin samples of Teflon (PTFE) at the Little Mountain Medusa LINAC facility in Ogden, UT. Three mil (76.2 microns) samples were irradiated with a 0.5 %CE%BCs pulse of 20 MeV electrons, yielding dose rates of 1E9 to 1E11 rad/s. We applied variable potentials up to 2 kV across the samples and measured the prompt conduction current. Details of the experimental apparatus and analysis are reported in this report on prompt RIC in Teflon.

  13. Measurements of prompt radiation induced conductivity of Kapton.

    Energy Technology Data Exchange (ETDEWEB)

    Preston, Eric F. (ITT Corporation, Colorado Springs, CO); Zarick, Thomas Andrew; Sheridan, Timothy J.; Hartman, E. Frederick; Stringer, Thomas Arthur (ITT Corporation, Colorado Springs, CO)

    2010-10-01

    We performed measurements of the prompt radiation induced conductivity in thin samples of Kapton (polyimide) at the Little Mountain Medusa LINAC facility in Ogden, UT. Three mil samples were irradiated with a 0.5 {mu}s pulse of 20 MeV electrons, yielding dose rates of 1E9 to 1E10 rad/s. We applied variable potentials up to 2 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 6E-17 and 2E-16 mhos/m per rad/s, depending on the dose rate and the pulse width.

  14. Absorption Measurement of Radiatively-Heated Low-z Mixture

    Institute of Scientific and Technical Information of China (English)

    YANG Jia-Min; DING Yao-Nan; ZHANG Bao-Han; YANG Guo-Hong; ZHENG Zhi-Jian; ZHANG Wen-Hai; WANG Yao-Mei; YAN Jun; LI Jia-Ming

    2001-01-01

    High-resolution transmission spectra of radiatively-heated low-z C10H16O6 plasma have been measured on 'Xing-guang Ⅱ' laser facility by using a flat field grating spectrometer. Absorption lines of oxygen and carbon ions in the region of 1.6-5.0nm have been observed clearly and identified. Using the unresolved transition array model,we also calculated the transmission spectra of C10H16O6 plasma. The measured transmission spectrum has beencompared with the calculated one.

  15. [Analyses of spectral emissivity in radiation temperature measurement].

    Science.gov (United States)

    Fu, Tai-Ran; Cheng, Xiao-Fang; Zhong, Mao-Hua; Yang, Zang-Jian

    2008-01-01

    The complexity of the spectral emissivity of actual surfaces is the key point in the research and applications of radiation temperature measurement, resulting in the difficulty in the achievement of the temperature measurement. In the present paper, based on the discussions of the Taylor expansion, the non-dimension wavelength and the exponent, the authors describe the mathematical expression of the spectral emissivity of actual surfaces, and establish the general spectral emissivity function. Through the fitting of experimental data of the spectral emissivities of different metals at different temperatures, the applicability of the spectral emissivity function is verified which especially becomes the fundamental in the research of primary spectrum pyrometry.

  16. Comparison of external udder measurements of the sheep breeds Improved Valachian, Tsigai, Lacaune and their crosses

    Directory of Open Access Journals (Sweden)

    Pavol Makovický

    2013-12-01

    Full Text Available Morphological udder traits have recently become of greater interest from farmers to researchers. In dairy ewes, the udder is very important due to its physiological and conformational characteristics. External udder traits were measured in ewes (Ovis aries L. of nine genotypes (355 ewes created of the basis of Improved Valachian (IV, Tsigai (T, and Lacaune (LC breeds (six traits; 1185 data for each trait during the milking period 2002-2008. Udder measurements were assessed for: udder length (UL, udder width (UW, rear udder depth (RUD, cistern depth (CDE, teat length (TL, and teat angle (TA. Data were processed by restricted maximum likelihood (REML methodology using a MIXED procedure from the SAS statistical package. All studied parameters were influenced by the genotype (P < 0.001, many of them also by the effect of parity and lactation stage. The exactly detected UL, UW and RUD during the lactation and with the age of ewes expand gradually (P < 0.001. Teat length was greater in older ewes (expanding, with the parity. Indicator TA during lactation worsened. Crosses with 25 to 75% share of genetic dairy breeds (in particular with LC, to a lesser extent 'East Friesian' -EF were in most cases larger than the udder cisterns of purebred ewes T and IV. Purebred LC had the largest udders, with the largest cisterns. In conclusion, crosses with specialized dairy breeds have more suitable udders for machine milking than purebred default breeds (T, IV, LC and are suitable for machine milking.

  17. Measurement of radiation dose at the north interaction point of BEPCⅡ

    Institute of Scientific and Technical Information of China (English)

    MO Xiao-Hu; ZHANG Jian-Yong; ZHANG Tian-Bao; ZHANG Qing-Jiang; Achasov Mikhail; FU Cheng-Dong; Muchnoi Nikolay; QIN Qing; QU Hua-Min; WANG Yi-Fang; WU Jing-Min; XU Jin-Qiang; YU Bo-Xiang

    2009-01-01

    The technique details for measuring radiation dose are expounded.The results of gamma and neutron radiation levels are presented and the corresponding radiation shielding is discussed based on the simplified estimation.In addition, the photon radiation level move as background for future experiments is measured by a NaI(T1) detector.

  18. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  19. Changes in Handset Performance Measures due to Spherical Radiation Pattern Measurement Uncertainty

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    An important characteristic of a mobile handset is its ability to receive and transmit power. One way to characterize the performance of a handset in this respect is to use measurements of the spherical radiation pattern from which the total radiated power (TRP), total isotropic sensitivity (TIS......), and mean effective gain (MEG) can be computed. Often this kind of measurements are made with a phantom head next to the handsets in order to simulate the influence of a real user. The measured radiation patterns are only expected to be repeatable if the same setup is used, i.e., the same phantom...... and the same mounting of the handset on the phantom. In this work the influence of mounting errors on the TRP, TIS, and MEG is investigated. Knowledge about the error due to incorrect mounting is necessary in determining requirements for both the mounting accuracy as well as for other parts of the measurement...

  20. Wall power measurements of impurity radiation in ORMAK

    Energy Technology Data Exchange (ETDEWEB)

    Bush, C.E.; Lyon, J.F.

    1977-12-01

    Time- and space-resolved measurements of the power loss to the liner of the Oak Ridge Tokamak (ORMAK) indicate that a large fraction (approx.60%) of the electron power input is lost to the wall, rather than to the limiter. This fraction is relatively constant over a wide range of input powers (ohmic heating plus neutral beam injection) and plasma conditions and for most of the discharge duration. Most of this energy loss is due to impurity radiation from an emission profile having a mean radius about a third that of the limiter radius and is time-correlated with gross plasma fluctuations, internal disruptions, and related spectroscopic impurity signals. In gas puffing experiments resulting in higher densities, the ratio of radiative power to the electron density continually falls as density increases during the course of the discharge.

  1. Measurement of radiative Bhabha and quasi-real Compton scattering

    CERN Document Server

    Acciarri, M; Aguilar-Benítez, M; Ahlen, S P; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Banerjee, S; Banerjee, Sw; Banicz, K; Barczyk, A; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Boldizsar, L; Borgia, B; Bourilkov, D; Bourquin, Maurice; Braccini, S; Branson, J G; Brigljevic, V; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Busenitz, J K; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chéreau, X J; Chiefari, G; Chien, C Y; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Coignet, G; Colijn, A P; Colino, N; Costantini, S; Cotorobai, F; de la Cruz, B; Csilling, Akos; Dai, T S; D'Alessandro, R; De Asmundis, R; Degré, A; Deiters, K; Della Volpe, D; Denes, P; De Notaristefani, F; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dova, M T; Duchesneau, D; Duinker, P; Durán, I; Easo, S; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabre, M; Faccini, R; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, Marta; Ferguson, T; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Fisk, I; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gau, S S; Gentile, S; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; Gougas, Andreas; Gratta, Giorgio; Grünewald, M W; van Gulik, R; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hartmann, B; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hidas, P; Hirschfelder, J; Van Hoek, W C; Hofer, H; Hoorani, H; Hou, S R; Hu, G; Iashvili, I; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamrad, D; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, D H; Kim, J K; Kim, S C; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Kopp, A; Korolko, I; Koutsenko, V F; Krämer, R W; Krenz, W; Kunin, A; Lacentre, P E; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lavorato, A; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee, H J; Le Goff, J M; Leiste, R; Leonardi, E; Levchenko, P M; Li Chuan; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lustermann, W; Ma Wen Gan; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangeol, D J J; Marchesini, P A; Marian, G; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Migani, D; Mihul, A; Van Mil, A J W; Milcent, H; Mirabelli, G; Mnich, J; Molnár, P; Monteleoni, B; Moore, R; Moulik, T; Mount, R; Muheim, F; Muijs, A J M; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Niessen, T; Nippe, A; Nisati, A; Nowak, H; Oh, Yu D; Organtini, G; Ostonen, R; Palit, S; Palomares, C; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Park, I H; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Peach, D; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petersen, B; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Pothier, J; Produit, N; Prokofev, D; Prokofiev, D O; Quartieri, J; Rahal-Callot, G; Raja, N; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riles, K; Robohm, A; Rodin, J; Roe, B P; Romero, L; Rosier-Lees, S; Roth, S; Rubio, Juan Antonio; Ruschmeier, D; Rykaczewski, H; Sakar, S; Salicio, J; Sánchez, E; Sanders, M P; Sarakinos, M E; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schwenke, J; Schwering, G; Sciacca, C; Sciarrino, D; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Shvorob, A V; Siedenburg, T; Son, D; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Stone, A; Stone, H; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Uchida, Y; Ulbricht, J; Valente, E; Vesztergombi, G; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Vlachos, S; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Z M; Weber, A; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zemp, P; Zeng, Y; Zhang, Z P; Zhou, B; Zhu, G Y; Zhu, R Y; Zichichi, Antonino; Ziegler, F; Zilizi, G

    1998-01-01

    We report on a study of radiative Bhabha and quasi-real Compton scattering at centre-of-mass energies between 50~{\\GeV} and 170~{\\GeV} and 20~{\\GeV} and 140~{\\GeV}, respectively, using the L3 detector at LEP. The analysis is based on data corresponding to an integrated luminosity of $232.2 \\,\\pb$. A total of 2856 radiative Bhabha and 4641 Compton scattering events are collected. Total and differential cross sections for both reactions are presented and found to be in good agreement with QED expectations. Our measurement of Compton scattering at the highest energies obtained so far is used to derive exclusion limits on the coupling $\\lambda$ for the on-shell production of an excited electron $\\e^{\\star}$ decaying into a $\\gamma\\e$ pair in the mass range $20 \\gev < m_{\\e^{\\star}} < 170 \\gev$.

  2. Electromagnetic Radiation Measurements and Safety Issues of some Cellular

    Directory of Open Access Journals (Sweden)

    A. Mousa

    2011-01-01

    Full Text Available As the mobile telecommunication systems are tremendously growing allover the world then the numbers of handheld andbase stations are also rapidly growing and it became very popular to see these base stations distributed everywhere in theneighborhood and on roof tops which has caused a considerable amount of panic to the public in Palestine concerning witherthe radiated electromagnetic field from these base stations may cause any health effect or hazard. This paper focuses on theradiated electromagnetic energy from some typical mobile base stations around the city of Nablus. The exposure levels dueto these stations were measured and compared to some international standard guidelines like ICNIRP and FCC to see if itmeets these standards, this is in order to answer some of the public fear and concern. The results are presented and somecomments are made on the other sources of electromagnetic radiation in the 200 kHz to 3 GHz range.

  3. Comparison of childhood thyroid cancer prevalence among 3 areas based on external radiation dose after the Fukushima Daiichi nuclear power plant accident: The Fukushima health management survey.

    Science.gov (United States)

    Ohira, Tetsuya; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Midorikawa, Sanae; Suzuki, Satoru; Fukushima, Toshihiko; Shimura, Hiroki; Ishikawa, Tetsuo; Sakai, Akira; Yamashita, Shunichi; Tanigawa, Koichi; Ohto, Hitoshi; Abe, Masafumi; Suzuki, Shinichi

    2016-08-01

    The 2011 Great East Japan Earthquake led to a subsequent nuclear accident at the Fukushima Daiichi Nuclear Power Plant. In its wake, we sought to examine the association between external radiation dose and thyroid cancer in Fukushima Prefecture. We applied a cross-sectional study design with 300,476 participants aged 18 years and younger who underwent thyroid examinations between October 2011 and June 2015. Areas within Fukushima Prefecture were divided into three groups based on individual external doses (≥1% of 5 mSv, <99% of 1 mSv/y, and the other). The odds ratios (ORs) and 95% confidence intervals of thyroid cancer for all areas, with the lowest dose area as reference, were calculated using logistic regression models adjusted for age and sex. Furthermore, the ORs of thyroid cancer for individual external doses of 1 mSv or more and 2 mSv or more, with the external dose less than 1 mSv as reference, were calculated. Prevalence of thyroid cancer for the location groups were 48/100,000 for the highest dose area, 36/100,000 for the middle dose area, and 41/100,000 for the lowest dose area. Compared with the lowest dose area, age-, and sex-adjusted ORs (95% confidence intervals) for the highest-dose and middle-dose areas were 1.49 (0.36-6.23) and 1.00 (0.67-1.50), respectively. The duration between accident and thyroid examination was not associated with thyroid cancer prevalence. There were no significant associations between individual external doses and prevalence of thyroid cancer. External radiation dose was not associated with thyroid cancer prevalence among Fukushima children within the first 4 years after the nuclear accident.

  4. Comparison of childhood thyroid cancer prevalence among 3 areas based on external radiation dose after the Fukushima Daiichi nuclear power plant accident

    Science.gov (United States)

    Ohira, Tetsuya; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Midorikawa, Sanae; Suzuki, Satoru; Fukushima, Toshihiko; Shimura, Hiroki; Ishikawa, Tetsuo; Sakai, Akira; Yamashita, Shunichi; Tanigawa, Koichi; Ohto, Hitoshi; Abe, Masafumi; Suzuki, Shinichi

    2016-01-01

    Abstract The 2011 Great East Japan Earthquake led to a subsequent nuclear accident at the Fukushima Daiichi Nuclear Power Plant. In its wake, we sought to examine the association between external radiation dose and thyroid cancer in Fukushima Prefecture. We applied a cross-sectional study design with 300,476 participants aged 18 years and younger who underwent thyroid examinations between October 2011 and June 2015. Areas within Fukushima Prefecture were divided into three groups based on individual external doses (≥1% of 5 mSv, <99% of 1 mSv/y, and the other). The odds ratios (ORs) and 95% confidence intervals of thyroid cancer for all areas, with the lowest dose area as reference, were calculated using logistic regression models adjusted for age and sex. Furthermore, the ORs of thyroid cancer for individual external doses of 1 mSv or more and 2 mSv or more, with the external dose less than 1 mSv as reference, were calculated. Prevalence of thyroid cancer for the location groups were 48/100,000 for the highest dose area, 36/100,000 for the middle dose area, and 41/100,000 for the lowest dose area. Compared with the lowest dose area, age-, and sex-adjusted ORs (95% confidence intervals) for the highest-dose and middle-dose areas were 1.49 (0.36–6.23) and 1.00 (0.67–1.50), respectively. The duration between accident and thyroid examination was not associated with thyroid cancer prevalence. There were no significant associations between individual external doses and prevalence of thyroid cancer. External radiation dose was not associated with thyroid cancer prevalence among Fukushima children within the first 4 years after the nuclear accident. PMID:27583855

  5. Comparisons of Air Radiation Model with Shock Tube Measurements

    Science.gov (United States)

    Bose, Deepak; McCorkle, Evan; Bogdanoff, David W.; Allen, Gary A., Jr.

    2009-01-01

    This paper presents an assessment of the predictive capability of shock layer radiation model appropriate for NASA s Orion Crew Exploration Vehicle lunar return entry. A detailed set of spectrally resolved radiation intensity comparisons are made with recently conducted tests in the Electric Arc Shock Tube (EAST) facility at NASA Ames Research Center. The spectral range spanned from vacuum ultraviolet wavelength of 115 nm to infrared wavelength of 1400 nm. The analysis is done for 9.5-10.5 km/s shock passing through room temperature synthetic air at 0.2, 0.3 and 0.7 Torr. The comparisons between model and measurements show discrepancies in the level of background continuum radiation and intensities of atomic lines. Impurities in the EAST facility in the form of carbon bearing species are also modeled to estimate the level of contaminants and their impact on the comparisons. The discrepancies, although large is some cases, exhibit order and consistency. A set of tests and analyses improvements are proposed as forward work plan in order to confirm or reject various proposed reasons for the observed discrepancies.

  6. Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Núria, E-mail: nrodriguez@parcdesalutmar.cat [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Universidad Pompeu Fabra, Barcelona (Spain); Sanz, Xavier [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Universidad Pompeu Fabra, Barcelona (Spain); Dengra, Josefa [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Foro, Palmira [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Universidad Pompeu Fabra, Barcelona (Spain); Membrive, Ismael; Reig, Anna [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Quera, Jaume [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Universidad Pompeu Fabra, Barcelona (Spain); Fernández-Velilla, Enric; Pera, Óscar; Lio, Jackson; Lozano, Joan [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Algara, Manuel [Department of Radiation Oncology, Hospital de la Esperanza, Parc de Salut MAR, Barcelona (Spain); Universidad Pompeu Fabra, Barcelona (Spain)

    2013-12-01

    Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P<.01). Late skin toxicity was no worse than grade 2 in either group, without significant differences between the 2 groups. In the ipsilateral breast, the areas that received the highest doses (ie, the boost or quadrant) showed the greatest loss of elasticity. WBI resulted in a greater loss of elasticity in the high-dose area compared with APBI (P<.05). Physician assessment showed that >75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with

  7. Nuclear fragmentation measurements for hadrontherapy and space radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    De Napoli, M. [INFN - Sezione di Catania (Italy); Agodi, C.; Blancato, A. A.; Cavallaro, M.; Cirrone, G. A. P.; Cuttone, G.; Sardina, D.; Scuderi, V. [INFN - Laboratori Nazionali del Sud (Italy); Battistoni, G. [INFN - Sezione di Milano (Italy); Bondi, M.; Cappuzzello, F.; Carbone, D.; Nicolosi, D.; Raciti, G.; Tropea, S. [INFN - Laboratori Nazionali del Sud, Italy and Dipartimento di Fisica e Astronomia, Universita degli Studi di Catania (Italy); Giacoppo, F. [Department of Physics, University of Oslo (Norway); Morone, M. C. [Dipartimento di Biopatologia e Diagnostica per Immagini, Universita di Roma Tor Vergata (Italy); Pandola, L. [INFN-Laboratori Nazionali del Gran Sasso (Italy); Rapisarda, E. [Nuclear and Radiation Physics Section, Katholieke Universiteit Leuven Celestijnenlaan Heverlee (Belgium); Romano, F. [INFN - Laboratori Nazionali del Sud (Italy) and Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi Roma (Italy); and others

    2013-04-19

    Nuclear fragmentation measurements are necessary in hadrontherapy and space radiation protection, to predict the effects of the ion nuclear interactions within the human body. Nowadays, a very limited set of carbon fragmentation cross sections has been measured and in particular, to our knowledge, no double differential fragmentation cross sections at intermediate energies are available in literature. We have measured the double differential cross sections and the angular distributions of the secondary fragments produced in the {sup 12}C fragmentation at 62 AMeV on a thin carbon target. The experimental data have been also used to benchmark the prediction capability of the Geant4 Monte Carlo code at intermediate energies, where it was never tested before.

  8. Background Radiation Measurements at High Power Research Reactors

    CERN Document Server

    Ashenfelter, J; Baldenegro, C X; Band, H R; Barclay, G; Bass, C D; Berish, D; Bowden, N S; Bryan, C D; Cherwinka, J J; Chu, R; Classen, T; Davee, D; Dean, D; Deichert, G; Dolinski, M J; Dolph, J; Dwyer, D A; Fan, S; Gaison, J K; Galindo-Uribarri, A; Gilje, K; Glenn, A; Green, M; Han, K; Hans, S; Heeger, K M; Heffron, B; Jaffe, D E; Kettell, S; Langford, T J; Littlejohn, B R; Martinez, D; McKeown, R D; Morrell, S; Mueller, P E; Mumm, H P; Napolitano, J; Norcini, D; Pushin, D; Romero, E; Rosero, R; Saldana, L; Seilhan, B S; Sharma, R; Stemen, N T; Surukuchi, P T; Thompson, S J; Varner, R L; Wang, W; Watson, S M; White, B; White, C; Wilhelmi, J; Williams, C; Wise, T; Yao, H; Yeh, M; Yen, Y -R; Zhang, C; Zhang, X

    2016-01-01

    Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $\\gamma$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

  9. Background radiation measurements at high power research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Ashenfelter, J. [Wright Laboratory, Department of Physics, Yale University, New Haven, CT 06520 (United States); Balantekin, B. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Baldenegro, C.X. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Band, H.R. [Wright Laboratory, Department of Physics, Yale University, New Haven, CT 06520 (United States); Barclay, G. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Bass, C.D. [Department of Chemistry and Physics, Le Moyne College, Syracuse, NY 13214 (United States); Berish, D. [Department of Physics, Temple University, Philadelphia, PA 19122 (United States); Bowden, N.S., E-mail: nbowden@llnl.gov [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Bryan, C.D. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Cherwinka, J.J. [Physical Sciences Laboratory, University of Wisconsin, Madison, WI 53706 (United States); Chu, R. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Department of Physics, University of Tennessee, Knoxville, TN 37996 (United States); Classen, T. [Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Davee, D. [Department of Physics, College of William and Mary, Williamsburg, VA 23187 (United States); Dean, D.; Deichert, G. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Dolinski, M.J. [Department of Physics, Drexel University, Philadelphia, PA 19104 (United States); Dolph, J. [Physics Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Dwyer, D.A. [Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Fan, S. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Department of Physics, University of Tennessee, Knoxville, TN 37996 (United States); and others

    2016-01-11

    Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

  10. Characterisation of spectrophotometers used for spectral solar ultraviolet radiation measurements.

    Science.gov (United States)

    Gröbner, J

    2001-01-01

    Spectrophotometers used for spectral measurements of the solar ultraviolet radiation need to be well characterised to provide accurate and reliable data. Since the characterisation and calibration are usually performed in the laboratory under conditions very different from those encountered during solar measurements, it is essential to address all issues concerned with the representativity of the laboratory characterisation with respect to the solar measurements. These include among others the instrument stability, the instrument linearity, the instrument responsivity, the wavelength accuracy, the spectral resolution, stray light rejection and the instrument dependence on ambient temperature fluctuations. These instrument parameters need to be determined often enough so that the instrument changes only marginally in the period between successive characterisations and therefore provides reliable data for the intervening period.

  11. Characterisation of spectrophotometers used for spectral solar ultraviolet radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Groebner, J

    2001-07-01

    Spectrophotometers used for spectral measurements of the solar ultraviolet radiation need to be well characterised to provide accurate and reliable data. Since the characterisation and calibration are usually performed in the laboratory under conditions very different from those encountered during solar measurements, it is essential to address all issues concerned with the representativity of the laboratory characterisation with respect to the solar measurements. These include amongst other the instrument stability, the instrument linearity, the instrument responsivity, the wavelength accuracy, the spectral resolution, stray light rejection and the instrument dependence on ambient temperature fluctuations. These instrument parameters need to be determined often enough so that the instrument changes only marginally in the period between successive characterisations and therefore provides reliable data for the intervening period. (author)

  12. Nuclear fragmentation measurements for hadrontherapy and space radiation protection

    Science.gov (United States)

    De Napoli, M.; Agodi, C.; Battistoni, G.; Blancato, A. A.; Bondı, M.; Cappuzzello, F.; Carbone, D.; Cavallaro, M.; Cirrone, G. A. P.; Cuttone, G.; Giacoppo, F.; Morone, M. C.; Nicolosi, D.; Pandola, L.; Raciti, G.; Rapisarda, E.; Romano, F.; Sardina, D.; Scuderi, V.; Sfienti, C.; Tropea, S.

    2013-04-01

    Nuclear fragmentation measurements are necessary in hadrontherapy and space radiation protection, to predict the effects of the ion nuclear interactions within the human body. Nowadays, a very limited set of carbon fragmentation cross sections has been measured and in particular, to our knowledge, no double differential fragmentation cross sections at intermediate energies are available in literature. We have measured the double differential cross sections and the angular distributions of the secondary fragments produced in the 12C fragmentation at 62 AMeV on a thin carbon target. The experimental data have been also used to benchmark the prediction capability of the Geant4 Monte Carlo code at intermediate energies, where it was never tested before.

  13. 3-D Measurement of Recycling and Radiation in MST

    Science.gov (United States)

    Norval, Ryan; Goetz, John; Schmitz, Oliver

    2016-10-01

    The MST reversed-field pinch (RFP) can undergo spontaneous transition to a helical core state, associated with the growth of the innermost resonant magnetic mode. Currently multiple 2-D imaging cameras are in place allowing for nearly full vessel viewing and measurement of recycling and impurities fluxes. The transition from the standard to helical RFP causes an observable change in edge plasma. While in the helical state the plasma wall interaction (PWI) on MSTs poloidal limiter strongly correlates with the helicity of the core mode. PWI on the toroidal limiter overall is reduced, with the remaining PWI sites corresponding the helicity of the core mode, or the locations of diagnostic limiters and the error fields they create. EIRENE, a neutral particle code use for modeling edge plasmas, is used to compute the neutral profiles based on measured recycling fluxes. EIRENE computes the radiative and charge exchange power losses. Comparison is made between the standard and helical RFP plasmas. Bolometer measurements of total radiation are currently in progress to supplement the modeling. This work is supported by the U.S. Department of Energy.

  14. Picosecond phase shift measurements at 358 MHz using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sabersky, A.P.; Munro, I.H.

    1978-07-01

    Properties of synchrotron radiation from SPEAR are reviewed. The power--frequency spectrum of source and photomultiplier tube is measured with a spectrum analyzer. The decay time of a single fluorescent species can be deduced by measuring the phase delay between excitation and fluorescence radiation modulated at a single suitable frequency. It is possible to characterize completely the time (impulse) response or the complex frequency response of a linear system with only phase measurements. A number of test experiments were made by using apparatus designed for time-resolved fluorescence emission anisotropy studies of tryptophan in proteins. Phase shifts were produced by insertion of water-filled quartz cells into the beam and by the introduction of a thick glass slab. The total optical path length could also be altered by linear motion of the phototube. The results yielded 4.7 +- 0.5 degrees per cm of motion. It was concluded that this procedure can be used to study short atomic and molecular fluorescence lifetimes. 3 figures. (RWR)

  15. Environmental assessment for the Atmospheric Radiation Measurement (ARM) Program: Southern Great Plains Cloud and Radiation Testbed (CART) site

    Energy Technology Data Exchange (ETDEWEB)

    Policastro, A.J.; Pfingston, J.M.; Maloney, D.M.; Wasmer, F.; Pentecost, E.D.

    1992-03-01

    The Atmospheric Radiation Measurement (ARM) Program is aimed at supplying improved predictive capability of climate change, particularly the prediction of cloud-climate feedback. The objective will be achieved by measuring the atmospheric radiation and physical and meteorological quantities that control solar radiation in the earth`s atmosphere and using this information to test global climate and related models. The proposed action is to construct and operate a Cloud and Radiation Testbed (CART) research site in the southern Great Plains as part of the Department of Energy`s Atmospheric Radiation Measurement Program whose objective is to develop an improved predictive capability of global climate change. The purpose of this CART research site in southern Kansas and northern Oklahoma would be to collect meteorological and other scientific information to better characterize the processes controlling radiation transfer on a global scale. Impacts which could result from this facility are described.

  16. 3D measurement of absolute radiation dose in grid therapy

    Energy Technology Data Exchange (ETDEWEB)

    Trapp, J V [Joint Department of Physics, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Department of Applied Physics, RMIT University, GPO Box 2476V, Melbourne 3001 (Australia); Warrington, A P [Joint Department of Physics, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Partridge, M [Joint Department of Physics, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Philps, A [Joint Department of Physics, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Leach, M O [Cancer Research UK Clinical MR Research Group, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Webb, S [Joint Department of Physics, Institute of Cancer Research and Royal Marsden Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2004-01-01

    Spatially fractionated radiotherapy through a grid is a concept which has a long history and was routinely used in orthovoltage radiation therapy in the middle of last century to minimize damage to the skin and subcutaneous tissue. With the advent of megavoltage radiotherapy and its skin sparing effects the use of grids in radiotherapy declined in the 1970s. However there has recently been a revival of the technique for use in palliative treatments with a single fraction of 10 to 20 Gy. In this work the absolute 3D dose distribution in a grid irradiation is measured for photons using a combination of film and gel dosimetry.

  17. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    Energy Technology Data Exchange (ETDEWEB)

    Stuardo B, E. (Comision Chilena de Energia Nuclear, Santiago. Dept. de Aplicaciones Nucleares)

    1983-11-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 ..mu..R/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found.

  18. [Measurement and evaluation of natural and artificial UV radiation].

    Science.gov (United States)

    Krins, A; Burger, P M; Dörschel, B; Knuschke, P

    1999-10-01

    Natural and artificial UV radiation are environmental factors with both beneficial and harmful biological effects. This article will explain the physical measurement quantities and their relation to the biologically effective dose and will summarize the present technical state of the art of personal UV monitoring. In practical use are dosimeters based on polysulphone, a polymer which undergoes changes in its optical properties upon irradiation with UV. Other systems determine the UV dose by quantifying damage induced in Bacillus subtilis spores upon UV exposure. An electronic UV sensor represents a new and interesting development. Personal UV dosimeters will become an useful tool in both clinical and scientific areas within dermatology.

  19. Cost-Effectiveness Analysis of Single Fraction of Stereotactic Body Radiation Therapy Compared With Single Fraction of External Beam Radiation Therapy for Palliation of Vertebral Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hayeon, E-mail: kimh2@upmc.edu [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Rajagopalan, Malolan S.; Beriwal, Sushil; Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Smith, Kenneth J. [Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania (United States)

    2015-03-01

    Purpose: Stereotactic body radiation therapy (SBRT) has been proposed for the palliation of painful vertebral bone metastases because higher radiation doses may result in superior and more durable pain control. A phase III clinical trial (Radiation Therapy Oncology Group 0631) comparing single fraction SBRT with single fraction external beam radiation therapy (EBRT) in palliative treatment of painful vertebral bone metastases is now ongoing. We performed a cost-effectiveness analysis to compare these strategies. Methods and Materials: A Markov model, using a 1-month cycle over a lifetime horizon, was developed to compare the cost-effectiveness of SBRT (16 or 18 Gy in 1 fraction) with that of 8 Gy in 1 fraction of EBRT. Transition probabilities, quality of life utilities, and costs associated with SBRT and EBRT were captured in the model. Costs were based on Medicare reimbursement in 2014. Strategies were compared using the incremental cost-effectiveness ratio (ICER), and effectiveness was measured in quality-adjusted life years (QALYs). To account for uncertainty, 1-way, 2-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay (WTP) threshold of $100,000 per QALY gained. Results: Base case pain relief after the treatment was assumed as 20% higher in SBRT. Base case treatment costs for SBRT and EBRT were $9000 and $1087, respectively. In the base case analysis, SBRT resulted in an ICER of $124,552 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of the utility of unrelieved pain; the utility of relieved pain after initial treatment and median survival were also sensitive to variation. If median survival is ≥11 months, SBRT cost <$100,000 per QALY gained. Conclusion: SBRT for palliation of vertebral bone metastases is not cost-effective compared with EBRT at a $100,000 per QALY gained WTP threshold. However, if median survival is ≥11 months, SBRT costs ≤$100

  20. Development of radiation detection and measurement system - Development of scintillation radiation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hee Dong; Kim, Wan [Kyungpook National University, Taegu (Korea); Kim, Do Sung [Taegu University, Taegu (Korea)

    2000-03-01

    We have been fabricated CsI(Tl) scintillation crystals and plastic scintillators for radiation-based measuring equipment. CsI (Tl) single crystals doped with thallium as an activator were grown using the Czochralski method. The crystal structure of grown CsI(Tl) was bcc, and it was confirmed that its lattice constant was 4,568 A. The spectral range of luminescence of CsI(Tl) was 350 {approx} 700 nm independent of thallium concentration, and the fast component of the luminescence was decreased with increasing thallium concentration. The energy resolution of CsI(Tl) scintillator doped with 0.1 mole% thallium was about 9% for 137 Cs {gamma}-rays. The relation formula of {gamma}-ray energy versus energy resolution was ln(FWHM%)=-0.705ln({epsilon})+6.75. The radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation dosage, and the irradiated crystals were colored reddish. The radiation induced absorption bands appeared around 355, 425, 520 and 555 nm, and their energy level were about 3.50, 2.88, 2.39 and 2.21 eV. Plastic scintillators were fabricated thermal polymerization method. Those were polymerizing at 120 deg. C, during 72 hours, and annealing at 75 deg. C, during 24 hours. When the concentration of 1st solute was 1.5 wt% and concentration of 2nd solute was 0.01 wt%, the characteristics of scintillation were very excellent. Also 3.0 wt% tetraphenyl lead were loaded to improve the detection efficiency of {gamma}-ray. The range of emission spectrum was 400 {approx} 450nm, and the central peak was 415 nm. The radiation damage was not appear under 1*10{sup 3}Gy, but the color of plastic scintillator was changed to brown, over 1*10{sup 4}Gy exposured. 84 refs., 39 figs. (Author)

  1. [The effect of long-term external ionizing radiation on the functional activity of rat thyroid under enhanced potassium iodide consumption].

    Science.gov (United States)

    Lupachik, S V; Nadol'nik, L I

    2008-01-01

    The study was devoted to the effect of long-term (20 days) external ionizing radiation at a dose of 0.5 Gy on the iodide metabolism in the rat thyroid under supplementation of high iodine doses (10 daily KI doses). It was found that the potassium iodide administration partially prevented the effects of a post radiation decrease of serum thyroid hormone levels (the level of T4 was normal and that of T3 was 77.4% of the controls). After the supplementation of 10 daily iodide doses, the rat thyroid tissue showed the most pronounced increase in the levels of total, free and protein-bound iodide compared to the groups of animals consuming normal and elevated KI doses. Pronounced inhibition of thyroid peroxidase activity (3.1-fold) was noted in the same group. The data obtained indicate a radiation-induced activation of iodide uptake during its enhanced supplementation and disturbed iodide enzymatic oxidation and organification.

  2. Normal tissue tolerance to external beam radiation therapy: Esophagus; Dose de tolerance a l'irradiation des tissus sains: l'oesophage

    Energy Technology Data Exchange (ETDEWEB)

    Bera, G.; Pointreau, Y. [Clinique d' oncologie-radiotherapie, centre Henry-S.-Kaplan, hopital Bretonneau, CHU de Tours, 37 - Tours (France); Denis, F.; Dupuis, O. [Centre Jean-Bernard, clinique Victor-Hugo, 72 - Le-Mans (France); Orain, I. [Service d' anatomie et cytologie pathologiques, hopital Trousseau, CHU de Tours, 37 - Tours (France); Crehange, G. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 21 - Dijon (France)

    2010-07-15

    The esophagus is a musculo-membranous tube through which food passes from the pharynx to the stomach. Due to its anatomical location, it can be exposed to ionizing radiation in many external radiotherapy indications. Radiation-induced esophageal mucositis is clinically revealed by dysphagia and odynophagia, and usually begins 3 to 4 weeks after the start of radiation treatment. With the rise of multimodality treatments (e.g., concurrent chemoradiotherapy, dose escalation and accelerated fractionation schemes), esophageal toxicity has become a significant dose-limiting issue. Understanding the predictive factors of esophageal injury may improve the optimal delivery of treatment plans. It may help to minimize the risks, hence increasing the therapeutic ratio. Based on a large literature review, our study describes both early and late radiation-induced esophageal injuries and highlights some of the predictive factors for cervical and thoracic esophagus toxicity. These clinical and dosimetric parameters are numerous but none is consensual. The large number of dosimetric parameters strengthens the need of an overall analysis of the dose/volume histograms. The data provided is insufficient to recommend their routine use to prevent radiation-induced esophagitis. Defining guidelines for the tolerance of the esophagus to ionizing radiation remains essential for a safe and efficient treatment. (authors)

  3. Can endocranial volume be estimated accurately from external skull measurements in great-tailed grackles (Quiscalus mexicanus?

    Directory of Open Access Journals (Sweden)

    Corina J. Logan

    2015-06-01

    Full Text Available There is an increasing need to validate and collect data approximating brain size on individuals in the field to understand what evolutionary factors drive brain size variation within and across species. We investigated whether we could accurately estimate endocranial volume (a proxy for brain size, as measured by computerized tomography (CT scans, using external skull measurements and/or by filling skulls with beads and pouring them out into a graduated cylinder for male and female great-tailed grackles. We found that while females had higher correlations than males, estimations of endocranial volume from external skull measurements or beads did not tightly correlate with CT volumes. We found no accuracy in the ability of external skull measures to predict CT volumes because the prediction intervals for most data points overlapped extensively. We conclude that we are unable to detect individual differences in endocranial volume using external skull measurements. These results emphasize the importance of validating and explicitly quantifying the predictive accuracy of brain size proxies for each species and each sex.

  4. BOREAS HYD-3 Subcanopy Incoming Solar Radiation Measurements

    Science.gov (United States)

    Hardy, Janet P.; Hall, Forrest G. (Editor); Knapp, David E. (Editor); Davis, Robert E.; Smith, David E. (Technical Monitor)

    2000-01-01

    The Boreal Ecosystem-Atmosphere Study (BOREAS) Hydrology (HYD)-3 team collected several data sets related to the hydrology of forested areas. This data set contains solar radiation measurements from several pyranometers (solar radiometers) placed on the snow surface in jack pine (1994) and black spruce and aspen forests (1996) in the BOREAS southern study area (SSA). An array of radiometers was used to collect data for three to four consecutive days in each forest type to study the hypothesis that energy transfer and snow water equivalent would vary spatially as a function of canopy closure. The quality of the data is good, because the days were generally clear and the radiometers were checked daily to remove anything that landed on the radiometers. The data are available in tabular ASCII files. The subcanopy incoming solar radiation measurement data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

  5. Measurements of prompt radiation induced conductivity of alumina and sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, E. Frederick [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zarick, Thomas Andrew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sheridan, Timothy J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Preston, Eric F. [ITT Coporation, Colorado Springs, CO (United States)

    2011-04-01

    We performed measurements of the prompt radiation induced conductivity in thin samples of Alumina and Sapphire at the Little Mountain Medusa LINAC facility in Ogden, UT. Five mil thick samples were irradiated with pulses of 20 MeV electrons, yielding dose rates of 1E7 to 1E9 rad/s. We applied variable potentials up to 1 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 1E10 and 1E9 mho/m/(rad/s), depending on the dose rate and the pulse width for Alumina and 1E7 to 6E7 mho/m/(rad/s) for Sapphire.

  6. Measurements of environmental radiation exposure dose rates at selected sites in Brazil.

    Science.gov (United States)

    Pfeiffer, W C; Penna-Franca, E; Ribeiro, C C; Nogueira, A R; Londres, H; Oliveira, A E

    1981-12-01

    Two types of portable instruments were developed by the former Health and Safety Laboratory of the U.S. Atomic Energy Commission to characterize external gamma radiation fields and to estimate individual exposure dose rates from major natural or fission radionuclides distributed in the soil: a pressurized ionization chamber and a NaI(T1) gamma-ray spectrometer. The two instruments were used to measure environmental radiation exposure rates at three distinct geological areas of Brazil: - in the towns of Guarapari and Meaípe located on the monazite sand belt, ES. - on the vicinities of the uranium mine of Poços de Caldas, MG. - around the site of the Brazilian first nuclear power plant, in Angra dos Reis, RJ. The radiometric survey demonstrated once more the usefulness and versatility of the two instruments used. The measurements around the nuclear installations of Poços de Caldas and Angra dos Reis, allowed a rapid assessment of the local radiation background and its variability, as well as the selection of stations for the routine monitoring program. Radioactive anomalies were detected and characterized previously to the start of plant operations. The survey in Guarapari and Meaípe confirmed the results obtained by Roser and Cullen in 1958 and 1962, except on sites where considerable changes took place since then. The spectrometric measurements gave estimations of the relative proportion of 40K, 238U and 232Th series in the ground and also indications on the homogeneity of their distribution in the soil.

  7. Quantitative estimation of the influence of external vibrations on the measurement error of a coriolis mass-flow meter

    NARCIS (Netherlands)

    Ridder, van de L.; Hakvoort, W.B.J.; Dijk, van J.; Lötters, J.C.; Boer, de A.; Dimitrovova, Z.; Almeida, de J.R.

    2013-01-01

    In this paper the quantitative influence of external vibrations on the measurement value of a Coriolis Mass-Flow Meter for low flows is investigated, with the eventual goal to reduce the influence of vibrations. Model results are compared with experimental results to improve the knowledge on how ext

  8. Impact of Measurement Invariance on Construct Correlations, Mean Differences, and Relations with External Correlates: An Illustrative Example Using Big Five and RIASEC Measures

    Science.gov (United States)

    Schmitt, Neal; Golubovich, Juliya; Leong, Frederick T. L.

    2011-01-01

    The impact of measurement invariance and the provision for partial invariance in confirmatory factor analytic models on factor intercorrelations, latent mean differences, and estimates of relations with external variables is investigated for measures of two sets of widely assessed constructs: Big Five personality and the six Holland interests…

  9. Impact of Measurement Invariance on Construct Correlations, Mean Differences, and Relations with External Correlates: An Illustrative Example Using Big Five and RIASEC Measures

    Science.gov (United States)

    Schmitt, Neal; Golubovich, Juliya; Leong, Frederick T. L.

    2011-01-01

    The impact of measurement invariance and the provision for partial invariance in confirmatory factor analytic models on factor intercorrelations, latent mean differences, and estimates of relations with external variables is investigated for measures of two sets of widely assessed constructs: Big Five personality and the six Holland interests…

  10. Space charge dosimeters for extremely low power measurements of radiation in shipping containers

    Science.gov (United States)

    Britton, Jr.; Charles L.; Buckner, Mark A.; Hanson, Gregory R.; Bryan, William L.

    2011-04-26

    Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

  11. Atmospheric Radiation Measurement Climate Research Facility (ACRF) Annual Report 2007

    Energy Technology Data Exchange (ETDEWEB)

    LR Roeder

    2007-12-01

    This annual report describes the purpose and structure of the program, and presents key accomplishments in 2007. Notable achievements include: • Successful review of the ACRF as a user facility by the DOE Biological and Environmental Research Advisory Committee. The subcommittee reinforced the importance of the scientific impacts of this facility, and its value for the international research community. • Leadership of the Cloud Land Surface Interaction Campaign. This multi-agency, interdisciplinary field campaign involved enhanced surface instrumentation at the ACRF Southern Great Plains site and, in concert with the Cumulus Humilis Aerosol Processing Study sponsored by the DOE Atmospheric Science Program, coordination of nine aircraft through the ARM Aerial Vehicles Program. • Successful deployment of the ARM Mobile Facility in Germany, including hosting nearly a dozen guest instruments and drawing almost 5000 visitors to the site. • Key advancements in the representation of radiative transfer in weather forecast models from the European Centre for Medium-Range Weather Forecasts. • Development of several new enhanced data sets, ranging from best estimate surface radiation measurements from multiple sensors at all ACRF sites to the extension of time-height cloud occurrence profiles to Niamey, Niger, Africa. • Publication of three research papers in a single issue (February 2007) of the Bulletin of the American Meteorological Society.

  12. Simplified calibration for broadband solar ultraviolet radiation measurements.

    Science.gov (United States)

    Oppenrieder, A; Hoeppe, P; Koepke, P; Reuder, J; Schween, J; Schreder, J

    2003-12-01

    Aspects of different calibration procedures for erythemally weighing broadband radiometers are presented in this study. These instruments are common in projects dealing with ultraviolet radiation effects on humans. Many erythemally weighing broadband radiometers are still operated using a single calibration factor (cf) that is provided with the instrument. The individual characteristics of every instrument are strongly dependent on the total ozone amount and the solar elevation. Therefore, a calibration procedure also has to take into account the ozone concentrations and the solar elevation to compensate for the effects of the individual characteristics and to provide comparable measurements. Given the variation of the ozone concentrations and the solar elevation, an individual cf has to be calculated for every measurement. Using a simplified version of the calibration procedure, which is presented in this study, can lessen this effort. Taking into account the relevant meteorological conditions for a measuring site, a single cf is calculated to compensate the individual characteristics of the instruments and therefore deliver comparable measurements with less effort.

  13. Margin selection to compensate for loss of target dose coverage due to target motion during external-beam radiation therapy of the lung.

    Science.gov (United States)

    Foster, W Kyle; Osei, Ernest; Barnett, Rob

    2015-01-08

    The aim of this study is to provide guidelines for the selection of external-beam radiation therapy target margins to compensate for target motion in the lung during treatment planning. A convolution model was employed to predict the effect of target motion on the delivered dose distribution. The accuracy of the model was confirmed with radiochromic film measurements in both static and dynamic phantom modes. 502 unique patient breathing traces were recorded and used to simulate the effect of target motion on a dose distribution. A 1D probability density function (PDF) representing the position of the target throughout the breathing cycle was generated from each breathing trace obtained during 4D CT. Changes in the target D95 (the minimum dose received by 95% of the treatment target) due to target motion were analyzed and shown to correlate with the standard deviation of the PDF. Furthermore, the amount of target D95 recovered per millimeter of increased field width was also shown to correlate with the standard deviation of the PDF. The sensitivity of changes in dose coverage with respect to target size was also determined. Margin selection recommendations that can be used to compensate for loss of target D95 were generated based on the simulation results. These results are discussed in the context of clinical plans. We conclude that, for PDF standard deviations less than 0.4 cm with target sizes greater than 5 cm, little or no additional margins are required. Targets which are smaller than 5 cm with PDF standard deviations larger than 0.4 cm are most susceptible to loss of coverage. The largest additional required margin in this study was determined to be 8 mm.

  14. Using global magnetospheric models for simulation and interpretation of Swarm external field measurements

    DEFF Research Database (Denmark)

    Moretto, T.; Vennerstrøm, Susanne; Olsen, Nils

    2006-01-01

    We have used a global model of the solar wind magnetosphere interaction to model the high latitude part of the external contributions to the geomagnetic field near the Earth. The model also provides corresponding values for the electric field. Geomagnetic quiet conditions were modeled to provide...

  15. A theoretical performance study of an external cavity fiber Fabry-Perot interferometer for displacement measurement

    Science.gov (United States)

    Arumugam, Kumar

    The objective of this research is to explore a mathematical model developed by Wilkinson and Pratt for the external cavity fiber-based Fabry-Perot interferometer (EFPI) and to create a Michelson interferometer setup to validate a frequency modulation component of this model. A laser diode with nominal wavelength 635 nm is modulated by oscillating the diode current of maximum amplitude 22.62 mA to create correspondingly varying wavelength. Experiments are included to evaluate a rotating vector representation of the modulation harmonics in the signal received at the photodetector as of a cube corner translated by a piezo-electric actuator is displaced. Wavelength modulation as a function of diode current, the coherence length of the laser, and characteristics of the modulation harmonics are evaluated. A real time DAQ system and two lock-in amplifiers are utilized for detecting three side-band harmonics of the signal. For short range displacements this interferometer setup is monitored using a capacitance displacement sensor. The capacitance displacement measurement differed from the Michelson interferometer by 160 nm. The piezoelectric stage actuated with a 15 V Ramp signal produced 2.54 mum displacement of the cube corner. The setup is tested with Ramp signals of 75 V to 1.5 V and with the Ramp periods of 1 to 20 seconds to find the resolution of the interferometer, modulation of the wavelength sensitivity and the coherence length of the laser as 10.53 nm, 1.786 nm·A-1 and >1 m respectively. The best quadrature signal achieved corresponded to modulating the laser at amplitude of 18.86 mA at 1 kHz frequency with a path length difference of 6.35 mm. The amplitude comparison of side-band harmonics with Bessel function curves is consistent with a modulation amplitude of 1.28 rad corresponding to amplitude ratios of 0.5 (second and first) , 0.15 (third and second) and 0.06 (third and first) in the first through third Bessel function values.

  16. new model for solar radiation estimation from measured air ...

    African Journals Online (AJOL)

    HOD

    Nigerian Meteorological Agency (NIMET) were used as inputs to the ANFIS model and monthly mean global solar radiation was ... models were used to predict solar radiation in Nigeria by. [12-15]. .... calculate them as total output [32] and [34].

  17. measurement of indoor background ionizing radiation in some

    African Journals Online (AJOL)

    Administrator

    ABSTRACT. Certain types of building materials are known to be radioactive. ... Indoor background ionizing radiation profiles for a building are ..... Survey of Radiation Levels during. Radiological Examinations in some selected Hospitals in Jos,.

  18. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2016-01-01

    Full Text Available Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary. According to the results of the integral heat transfer analysis were established that the average Nusselt number (Nuav increasing occurs up to τ = 200 (dimensionless time. Further Nuav has changed insignificantly due to the temperature field equalization near the interfaces “gas – wall”.

  19. Measurement and analysis of coherent synchrotron radiation effects at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Beutner, B.

    2007-12-15

    The vacuum-ultra-violet Free Electron Laser in Hamburg (FLASH) is a linac driven SASE-FEL. High peak currents are produced using magnetic bunch compression chicanes. In these magnetic chicanes, the energy distribution along an electron bunch is changed by eff ects of Coherent Synchrotron Radiation (CSR). Energy changes in dispersive bunch compressor chicanes lead to transverse displacements along the bunch. These CSR induced displacements are studied using a transverse deflecting RF-structure. Experiments and simulations concerning the charge dependence of such transverse displacements are presented and analysed. In these experiments an over-compression scheme is used which reduces the peak current downstream the bunch compressor chicanes. Therefore other self interactions like space charge forces which might complicate the measurements are suppressed. Numerical simulations are used to analyse the beam dynamics under the influence of CSR forces. The results of these numerical simulations are compared with the data obtained in the over-compression experiments at FLASH. (orig.)

  20. Atmospheric Radiation Measurement (ARM) Climate Research Facility Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Mather, James [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-04-01

    Mission and Vision Statements for the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mission The ARM Climate Research Facility, a DOE scientific user facility, provides the climate research community with strategically located in situ and remote-sensing observatories designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols as well as their interactions and coupling with the Earth’s surface. Vision To provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes to resolve the uncertainties in climate and Earth system models toward the development of sustainable solutions for the nation's energy and environmental challenges.

  1. Radiation pressure efficiency measurements of nanoparticle coated microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Y. [National Research Council, Research Associateship Programs, 500 Fifth Street NW (Keck 568), Washington, D.C. 20001 (United States); Taylor, Joseph D.; Ladouceur, Harold D.; Hart, Sean J.; Terray, Alex, E-mail: terray@nrl.navy.mil [Naval Research Laboratory, Chemistry Division, Bioanalytical Chemistry, Code 6112, 4555 Overlook Avenue S.W., Washington, D.C. 20375 (United States)

    2013-12-02

    Experimental measurements of the radiation pressure efficiency (Q{sub pr}) for several microparticles have been compared to theoretical calculations extrapolated from the Bohren-Huffman code for Mie scattering of coated particles. An increased shift of the Q{sub pr} parameter was observed for 2 μm SiO{sub 2} core particles coated with nanoparticles of higher refractive indices. Coatings of 14 nm melamine particles were found to increase the Q{sub pr} parameter 135 times over similar coatings using SiO{sub 2} particles of the same size. While a coating of 100 nm polystyrene particles also showed a significant increase, they did not agree well with theoretical values. It is hypothesized that other factors such as increased scatter, drag, and finite coating coverage are no longer negligible for coatings using nanoparticles in this size regime.

  2. Radiation pressure efficiency measurements of nanoparticle coated microspheres

    Science.gov (United States)

    Kim, Soo Y.; Taylor, Joseph D.; Ladouceur, Harold D.; Hart, Sean J.; Terray, Alex

    2013-12-01

    Experimental measurements of the radiation pressure efficiency (Qpr) for several microparticles have been compared to theoretical calculations extrapolated from the Bohren-Huffman code for Mie scattering of coated particles. An increased shift of the Qpr parameter was observed for 2 μm SiO2 core particles coated with nanoparticles of higher refractive indices. Coatings of 14 nm melamine particles were found to increase the Qpr parameter 135 times over similar coatings using SiO2 particles of the same size. While a coating of 100 nm polystyrene particles also showed a significant increase, they did not agree well with theoretical values. It is hypothesized that other factors such as increased scatter, drag, and finite coating coverage are no longer negligible for coatings using nanoparticles in this size regime.

  3. Diffuse scattering measurements with synchrotron radiation: Instrumentation and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, E.; Georgopoulos, P.

    1985-12-01

    The analysis of diffuse scattering from single crystalline specimens in the reflection mode has generally been acknowledged as a very powerful means of obtaining structural information on local atomic arrangements in disordered alloys, intermetallics and ceramics. However, owing to the low intensities encountered and the large number of measurements required for such an analysis, experiments have been extremely time consuming and few have been attempted. Synchrotron radiation makes it possible to conduct such experiments in a matter of hours and much higher quality data can be obtained than in the laboratory. This paper describes the experimental procedures and methods applied to a study of Al-Cu age hardening alloys conducted at the Cornell Synchrotron Source (CHESS). (orig.).

  4. Why can’t I measure the external quantum efficiency of the Ge subcell of my multijunction solar cell?

    Energy Technology Data Exchange (ETDEWEB)

    Barrigón, Enrique, E-mail: enrique.barrigon@ies-def.upm.es; Espinet-González, Pilar; Contreras, Yedileth; Rey-Stolle, Ignacio [Instituto de Energía Solar, Universidad Politécnica de Madrid ETSI de Telecomunicación, Avd. Complutense 30, 28040 Madrid (Spain)

    2015-09-28

    The measurement of the external quantum efficiency (EQE) of low bandgap subcells in a multijunction solar cell can be sometimes problematic. In particular, this paper describes a set of cases where the EQE of a Ge subcell in a conventional GaInP/GaInAs/Ge triple-junction solar cell cannot be fully measured. We describe the way to identify each case by tracing the I-V curve under the same light-bias conditions applied for the EQE measurement, together with the strategies that could be implemented to attain the best possible measurement of the EQE of the Ge subcell.

  5. Indices using external measurements for assessing fat deposition of adult feral raccoons (Procyon lotor) in Kanagawa Prefecture, Japan.

    Science.gov (United States)

    Kato, Takuya; Uno, Taiki; Fujioka, Yoshiyuki; Hayama, Shin-Ichi

    2012-02-01

    We examined the use of external measurements and relative fat deposition of adult feral raccoons (Procyon lotor) to develop relative indices of body fat deposition in post-growth feral raccoons. From March 2006 to March 2010, 288 adult raccoon carcasses (110 males, 178 females) collected in Kanagawa Prefecture, Japan, which were determined to be 24 months old, were subjected to external measurements of body weight (BW), girth measurement (GM), and body mass index (BMI). To assess relative body fat deposition, we visually classified abdominal subcutaneous fat into three grades (Visible Fat Index [VFI]: I-III). Significant differences in the means of BW (both sexes:Praccoons in Kanagawa Prefecture and may be generalizable to populations in other areas.

  6. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F.; Calzolai, G.; Chiari, M.; Mochi, D.; Nava, S. [Department of Physics, University of Florence and INFN, Florence (Italy)

    2013-07-01

    Full text: Particle Induced X-ray Emission (PIXE)technique has been widely used since its birth for the study of the aerosol composition, and for a long time it has been the dominating technique for its elemental analysis. However now it has to compete with other techniques, like Induced Coupled Plasma and detection by Atomic Emission Spectroscopy (ICP-AES) or Mass Spectrometry (ICP-MS) or Synchrotron Radiation XRF (SR-XRF). To remain competitive, a proper experimental set-up is important to fully exploit PIXE capabilities. At LABEC, an external beam line is fully dedicated to PIXE-PIGE measurements of atmospheric aerosols [1]. Recently SDD (Silicon Drift Detectors) have been introduced for X-ray detection thanks to their better resolution with respect to Si(Li) detectors and the possibility of managing high counting rates (up to 50 kHz at 0.5 μsec shaping time). This implies, in turn, the possibility of using very high beam currents thus drastically reducing the measurement time. However their use for a complete characterization of X-rays was limited by the small thickness and surface areas available. Now SDD with a thickness of 500 μm and 80 mm{sup 2} area have been introduced in the market. We have therefore replaced the Si(Li) detector used so far for the detection of medium-high Z elements with such a SDD. A comparison of the two detectors has been carried out; PIXE minimum detection limits (MDLs) at different proton beam energies have been studied to find out the best energy for PIXE measurements on aerosol samples collected on different substrata, namely Teflon, Kapton, Nuclepore and Kimfol, used for daily or hourly sampling or for cascade impactors. In particular in the case of Teflon filters, the production of γ-rays by F in the Teflon filter limits the current which may be used and the Compton γ-ray background worsens the MDLs. Due to the lower thickness of the SDD detector with respect to a typical Si(Li) detector, these problems are reduced

  7. Effect of External Radiation Filed on the Properties of the Atoms and Cavity Field in the Tavis-Cummings Model

    Institute of Scientific and Technical Information of China (English)

    王忠纯

    2004-01-01

    @@ We study the properties of the atoms and cavity field in the Tavis-Cummings Model where the two atoms interact each other and also are driven by an external classical field.We consider the special case that the cavity is initially in a coherent state.After work out the atomic inversion, the average photons number and the Mandel parameter in the driven Tavis-Cummings Model, we do numerical analysis of them, and pay special attention to the dynamical behavior of the atoms and the cavity field modified by the external field.

  8. Determination of dose conversion factors for external gamma radiation in dwellings; Determinacao de fatores de conversao de dose para radiacao gama externa em residencias

    Energy Technology Data Exchange (ETDEWEB)

    Maduar, Marcelo Francis

    2000-07-01

    The use of building materials containing natural radionuclides in dwelling construction may lead to an increment of both external and internal radiation exposure of the population. External exposure in dwellings arises from gamma-emitter radionuclides existing in the walls, floor and ceiling. Mathematical models can be used to predict external dose rates inside the room, provided the radionuclide concentration activities in dwelling constituents and the building geometry are known. In this work, a methodology and a computer code, called EDVOS, for theoretical evaluation of external gamma doses in the air, due to radionuclides present in the constituents of an hypothetical room, were developed. The room is modeled as three pairs of rectangular sheets with finite thickness. Evaluation of doses was performed through the application of a photon transport model, taking into account self-absorption and radiation buildup. The radionuclides were assumed to be uniformly distributed in the building materials. Calculations were performed for concrete walls and results are presented for {sup 40}K, {sup 226} Ra, and {sup 232}Th, taking into account, for dose calculations, all gamma emitters from {sup 226}Ra and {sup 232}Th decay chains. The response of the model to the input parameters was studied by varying each of them within a reasonable range of applicability, while leaving the other ones at fixed selected values. The results obtained showed a good agreement with those presented in the literature and with data obtained by running RESRAD-BUILD code. Dose conversions factors are presented in a form suitable for the use in radiological impact studies applied to practical situations. (author)

  9. Design and implementation of automatic shading device for diffuse radiation measurement

    Institute of Scientific and Technical Information of China (English)

    LYU; Wenhua; BIAN; Zeqiang; CHONG; Wei

    2015-01-01

    Considering the problem of too large area the shading disc covered,complex shadow band coefficients and too big diffuse radiation measurement bias,an automatic shading device for diffuse radiometer is designed and realized. Set a shading ball on the automatic sun tracker,drive linkage parallelogram structure with the declination axis arm,the shading ball can rotate synchronously with the motion of the sun and shade beam radiation measured with pyranometer,thus shading beam radiation and measuring diffuse radiation can be realized automatically. The comparison test results show that the automatic shading device can realize diffuse radiation measurement automatically,the accuracy of diffuse radiation readings can get a 18. 7% improvement compared with traditional measure system,greatly improves the reliability and accuracy of the diffuse radiation measurement.

  10. Short-term Androgen-Deprivation Therapy Improves Prostate Cancer-Specific Mortality in Intermediate-Risk Prostate Cancer Patients Undergoing Dose-Escalated External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zumsteg, Zachary S.; Spratt, Daniel E.; Pei, Xin; Yamada, Yoshiya; Kalikstein, Abraham [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Kuk, Deborah; Zhang, Zhigang [Department of Epidemiology and Biostatistics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2013-03-15

    Purpose: We investigated the benefit of short-term androgen-deprivation therapy (ADT) in patients with intermediate-risk prostate cancer (PC) receiving dose-escalated external beam radiation therapy. Methods and Materials: The present retrospective study comprised 710 intermediate-risk PC patients receiving external beam radiation therapy with doses of ≥81 Gy at a single institution from 1992 to 2005, including 357 patients receiving neoadjuvant and concurrent ADT. Prostate-specific antigen recurrence-free survival (PSA-RFS) and distant metastasis (DM) were compared using the Kaplan-Meier method and Cox proportional hazards models. PC-specific mortality (PCSM) was assessed using competing-risks analysis. Results: The median follow-up was 7.9 years. Despite being more likely to have higher PSA levels, Gleason score 4 + 3 = 7, multiple National Comprehensive Cancer Network intermediate-risk factors, and older age (P≤.001 for all comparisons), patients receiving ADT had improved PSA-RFS (hazard ratio [HR], 0.598; 95% confidence interval [CI], 0.435-0.841; P=.003), DM (HR, 0.424; 95% CI, 0.219-0.819; P=.011), and PCSM (HR, 0.380; 95% CI, 0.157-0.921; P=.032) on univariate analysis. Using multivariate analysis, ADT was an even stronger predictor of improved PSA-RFS (adjusted HR [AHR], 0.516; 95% CI, 0.360-0.739; P<.001), DM (AHR, 0.347; 95% CI, 0.176-0.685; P=.002), and PCSM (AHR, 0.297; 95% CI, 0.128-0.685; P=.004). Gleason score 4 + 3 = 7 and ≥50% positive biopsy cores were other independent predictors of PCSM. Conclusions: Short-term ADT improves PSA-RFS, DM, and PCSM in patients with intermediate-risk PC undergoing dose-escalated external beam radiation therapy.

  11. An analysis of Japan radiation protection measurements after the Fukushima nuclear accident

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Arlene A. dos; Souza-Santos, Denison; Melo, Dunstana R. de; Hunt, John G.; Juliao, Ligia M.Q C.; Conti, Luiz F.C.; Pires do Rio, Monica A.; Reis, Rocio G., E-mail: arlene@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    On March 11th 2011, Japan was struck by a devastating earthquake followed by a tsunami wave that took the lives of thousands and started a major nuclear accident in the Fukushima Dai-ichi power plant complex. Right from the beginning, the information published by the Japanese government and by the International Atomic Energy Agency (IAEA) was followed by a team of experts at the Institute for Radiation Protection and Dosimetry (IRD) of Brazil. Radiation monitoring data, such as radionuclide activity concentration in water and food, ambient dose rate and fallout concentration in specific cities have been compiled and analyzed, with emphasis on dose limits established by Brazilian regulatory authority. A computer code for dose assessment, developed at the IRD and based upon the IAEA documents TECDOC-1162 and TECDOC-955, was used to assess the doses due to intakes of radionuclides and external exposure for individuals of different age groups. The IAEA model predictions for the ambient dose rates, when the fallout is known, are compared with the measured values in different cities. The Japanese recommendations for evacuation, sheltering and restriction of food and water consumption are evaluated with regards to the Brazilian limits defined in the CNEN NN 3.01 standard. (author)

  12. Experimentally Measured Radiative Lifetimes and Oscillator Strengths in Neutral Vanadium

    Science.gov (United States)

    Holmes, C. E.; Pickering, J. C.; Ruffoni, M. P.; Blackwell-Whitehead, R.; Nilsson, H.; Engström, L.; Hartman, H.; Lundberg, H.; Belmonte, M. T.

    2016-06-01

    We report a new study of the V i atom using a combination of time-resolved laser-induced fluorescence and Fourier transform spectroscopy that contains newly measured radiative lifetimes for 25 levels between 24,648 cm-1 and 37,518 cm-1 and oscillator strengths for 208 lines between 3040 and 20000 Å from 39 upper energy levels. Thirteen of these oscillator strengths have not been reported previously. This work was conducted independently of the recent studies of neutral vanadium lifetimes and oscillator strengths carried out by Den Hartog et al. and Lawler et al., and thus serves as a means to verify those measurements. Where our data overlap with their data, we generally find extremely good agreement in both level lifetimes and oscillator strengths. However, we also find evidence that Lawler et al. have systematically underestimated oscillator strengths for lines in the region of 9000 ± 100 Å. We suggest a correction of 0.18 ± 0.03 dex for these values to bring them into agreement with our results and those of Whaling et al. We also report new measurements of hyperfine structure splitting factors for three odd levels of V i lying between 24,700 and 28,400 cm-1.

  13. Olfactory Neuroblastoma Treated by Endoscopic Surgery Followed by Combined External Beam Radiation and Gamma Knife for Optic Nerve and Chiasm Sparing: A Case Report

    Directory of Open Access Journals (Sweden)

    Hansi Z. Jiang

    2011-01-01

    Full Text Available We describe the multimodality treatment regimen of a 53-year-old man diagnosed with olfactory neuroblastoma (Kadish stage C in the right nasal cavity extending into the ethmoid sinus and across the cribriform plate. Endoscopic surgery for tumor resection was followed by a combination of external beam radiotherapy and stereotactic radiosurgery boost with concurrent chemotherapy. The novel combination of dual radiation therapies allowed for the preservation of the nearby optic structures while providing an adequate dosage to a sufficient volume of the afflicted tissue.

  14. Modular Architecture for the Measurement of Space Radiation

    Science.gov (United States)

    Delaune, Paul; Turner, Kathryn; Holland, S. Douglas; Carson, William R.; Riman, Fadi

    2007-01-01

    A modular architecture has been conceived for the design of radiation-monitoring instruments used aboard spacecraft and in planetary-exploration settings. This architecture reflects lessons learned from experience with prior radiation-monitoring instruments. A prototype instrument that embodies the architecture has been developed as part of the Mars Advanced Radiation Acquisition (MARA) project. The architecture is also applicable on Earth for radiation-monitoring instruments in research of energetic electrically charged particles and instruments monitoring radiation for purposes of safety, military defense, and detection of hidden nuclear devices and materials.

  15. Human exposition to non ionizing electromagnetic radiations. Legislation and base stations measurements

    Directory of Open Access Journals (Sweden)

    Alonso Alonso Alonso

    2004-12-01

    Full Text Available This work deals about measurement procedures of non-ionizing radiations and their recorded levels in practice. The analyzed radiation sources cover the most common broadcasting media such as AM and FM transmissions and the GSM mobile telephony base stations. These sources currently radiate locations with high density of population. Spanish radiation level regulations are briefly described and some possible improvements are pointed out. The measurement results are discussed.

  16. Personnel radiation protection. Situation of the dosimetry surveillance of external exposure in 2003; La radioprotection des travailleurs. Bilan de la surveillance dosimetrique de l'exposition externe en 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The situation of external exposure of workers for the year 2003 has been realised according to the same method than this one of the year 2002. It does not show big variations of trends, both in term of workforce watched and collective doses alike associated in the different sectors of activity. Some differences observed between the two years can explain by real evolutions of situations. For example, the 2800 workers registered in the veterinary sector are the result of a better awareness of this profession for the radiation protection during the last months. Some variations can be the results of artefacts in the data processing. The centralization at I.R.S.N. of the whole of dosimetry data should allow to make easy the data treatment and to improve the statistics of occupational exposure. (N.C.)

  17. Challenges in Measuring External Currents Driven by the Solar Wind-Magnetosphere Interaction

    Science.gov (United States)

    Le, Guan; Slavin, James A.; Pfaff, Robert F.

    2014-01-01

    In studying the Earth's geomagnetism, it has always been a challenge to separate magnetic fields from external currents originating from the ionosphere and magnetosphere. While the internal magnetic field changes very slowly in time scales of years and more, the ionospheric and magnetospheric current systems driven by the solar wind -magnetosphere interaction are very dynamic. They are intimately controlled by the ionospheric electrodynamics and ionospheremagnetosphere coupling. Single spacecraft observations are not able to separate their spatial and temporal variations, and thus to accurately describe their configurations. To characterize and understand the external currents, satellite observations require both good spatial and temporal resolutions. This paper reviews our observations of the external currents from two recent LEO satellite missions: Space Technology 5 (ST-5), NASA's first three-satellite constellation mission in LEO polar orbit, and Communications/Navigation Outage Forecasting System (C/NOFS), an equatorial satellite developed by US Air Force Research Laboratory. We present recommendations for future geomagnetism missions based on these observations.

  18. Challenges in Measuring External Currents Driven by the Solar Wind-Magnetosphere Interaction

    Directory of Open Access Journals (Sweden)

    Guan Le

    2015-01-01

    Full Text Available In studying the _ geomagnetism it has always been a challenge to separate the external currents originating from the ionosphere and magnetosphere. While the internal magnetic field changes very slowly in time scales of years and more, the ionospheric and magnetospheric current systems driven by the solar wind-magnetosphere interaction are very dynamic. They are intimately controlled by the ionospheric electrodynamics and ionosphere-magnetosphere coupling. Single spacecraft observations are not able to separate their spatial and temporal variations, and thus to accurately describe their configurations. To characterize and understand the external currents, satellite observations require both good spatial and temporal resolutions. This paper reviews our observations of the external currents from two recent Low Earth Orbit (LEO satellite missions: Space Technology 5 (ST-5, _ first three-satellite constellation mission in LEO polar orbit and Communications/Navigation Outage Forecasting System (C/NOFS, an equatorial satellite developed by the US Air Force Research Laboratory. We present recommendations for future geomagnetism missions based on these observations.

  19. INSTRUMENTATION FOR MEASURING AND TRANSMISSION THE SOLAR RADIATION THROUGH EARTH’S ATMOSPHERE

    Directory of Open Access Journals (Sweden)

    Alexandru Dan Toma

    2013-07-01

    Full Text Available The Sun's energy is distributed over a broad range of the electromagnetic spectrum and Sun behaves approximately like a "blackbody" radiating at a temperature of about 5800 K with maximum output in the green-yellow part of the visible spectrum, around 500 nm. Not all solar radiation reaching the top of the atmosphere reaches Earth's surface due to a various optical phenomena in regard to solar radiation crossing the Earth’s atmosphere. In order to investigate them, there are two general categories of instruments used to measure the transmission of solar radiation through Earth's atmosphere: instruments that measure radiation from the entire sky and instruments that measure only direct solar radiation. Within each of these categories, instruments can be further subdivided into those that measure radiation over a broad range of wavelengths and those that measure only specific wavelengths.

  20. Radiation Therapy

    Science.gov (United States)

    Radiation therapy is a cancer treatment. It uses high doses of radiation to kill cancer cells and stop them from ... half of all cancer patients receive it. The radiation may be external, from special machines, or internal, ...

  1. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Energy Technology Data Exchange (ETDEWEB)

    Paroli, B., E-mail: bruno.paroli@unimi.it [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Mostacci, A. [“La Sapienza” University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Petrillo, V.; Potenza, M.A.C.; Rossi, A.R.; Serafini, L. [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy)

    2015-07-15

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1–10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF)

  2. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Science.gov (United States)

    Paroli, B.; Chiadroni, E.; Ferrario, M.; Mostacci, A.; Petrillo, V.; Potenza, M. A. C.; Rossi, A. R.; Serafini, L.

    2015-07-01

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1-10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF).

  3. Monte Carlo analysis of radiative transport in oceanographic lidar measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cupini, E.; Ferro, G. [ENEA, Divisione Fisica Applicata, Centro Ricerche Ezio Clementel, Bologna (Italy); Ferrari, N. [Bologna Univ., Bologna (Italy). Dipt. Ingegneria Energetica, Nucleare e del Controllo Ambientale

    2001-07-01

    The analysis of oceanographic lidar systems measurements is often carried out with semi-empirical methods, since there is only a rough understanding of the effects of many environmental variables. The development of techniques for interpreting the accuracy of lidar measurements is needed to evaluate the effects of various environmental situations, as well as of different experimental geometric configurations and boundary conditions. A Monte Carlo simulation model represents a tool that is particularly well suited for answering these important questions. The PREMAR-2F Monte Carlo code has been developed taking into account the main molecular and non-molecular components of the marine environment. The laser radiation interaction processes of diffusion, re-emission, refraction and absorption are treated. In particular are considered: the Rayleigh elastic scattering, produced by atoms and molecules with small dimensions with respect to the laser emission wavelength (i.e. water molecules), the Mie elastic scattering, arising from atoms or molecules with dimensions comparable to the laser wavelength (hydrosols), the Raman inelastic scattering, typical of water, the absorption of water, inorganic (sediments) and organic (phytoplankton and CDOM) hydrosols, the fluorescence re-emission of chlorophyll and yellow substances. PREMAR-2F is an extension of a code for the simulation of the radiative transport in atmospheric environments (PREMAR-2). The approach followed in PREMAR-2 was to combine conventional Monte Carlo techniques with analytical estimates of the probability of the receiver to have a contribution from photons coming back after an interaction in the field of view of the lidar fluorosensor collecting apparatus. This offers an effective mean for modelling a lidar system with realistic geometric constraints. The retrieved semianalytic Monte Carlo radiative transfer model has been developed in the frame of the Italian Research Program for Antarctica (PNRA) and it is

  4. Status of radiation damage measurements in room temperature semiconductor radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Franks, L.A.; James, R.B.

    1998-04-01

    The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed for the purpose of determining their applicability to space applications. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. CT detectors show resolution losses after fluences of 3 {times} 10{sup 9} p/cm{sup 2} at 33 MeV for chlorine-doped detectors. Indium doped material may be more resistant. Neutron exposures (8 MeV) caused resolution losses after fluences of 2 {times} 10{sup 10} n/cm{sup 2}. Mercuric iodide has been studied with intermediate energy protons (10 to 33 MeV) at fluences up to 10{sup 12} p/cm{sup 2} and with 1.5 GeV protons at fluences up to 1.2 {times} 10{sup 8} p/cm{sup 2}. Neutron exposures at 8 MeV have been reported at fluences up to 10{sup 15} n/cm{sup 2}. No radiation damage was found under these irradiation conditions.

  5. Normal tissue tolerance to external beam radiation therapy: Small bowel; Dose de tolerance a l'irradiation des tissus sains: intestin grele

    Energy Technology Data Exchange (ETDEWEB)

    Martin, E. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 21 - Dijon (France); Pointreau, Y.; Barillot, I. [Service de radiotherapie, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau, CHRU de Tours, 37 - Tours (France); Roche-Forestier, S. [Centre Jean-Bernard, 72 - Le Mans (France); Barillot, I. [Universite Francois-Rabelais, centre de cancerologie Henry-S.-Kaplan, CHU de Tours, 37 - Tours (France)

    2010-07-15

    The small bowel is a hollow organ involved in the transit and absorption of food. In relation to its anatomical location, a significant amount of this organ is exposed in whole or in part to ionizing radiation in external radiotherapy during abdominal or pelvic irradiation either for primary cancers or metastasis. The acute functional changes during external beam radiation are mainly leading to diarrhea, abdominal pain and bloating. The main late side effects of irradiation of the small intestine are chronic diarrhea, malabsorption with steatorrhoea, abdominal spasms, intestinal obstruction, bleeding and fistulas. The architecture of the small intestine may be considered as parallel with a significant correlation between the irradiated volume of small bowel and the likelihood of acute toxicity, whatever the dose. The literature analysis recommends to consider the volume of small bowel receiving 15 Gy (threshold of 100 to 200 cm{sup 3}) but also 30 and 50 Gy (thresholds of 35 to 300 cm{sup 3}, depending on the level of dose considered). Modern techniques of conformal radiotherapy with modulated intensity will probably have beneficial impact on small bowel toxicity. (authors)

  6. Computational Fluid Dynamics Analysis on Radiation Error of Surface Air Temperature Measurement

    Science.gov (United States)

    Yang, Jie; Liu, Qing-Quan; Ding, Ren-Hui

    2017-01-01

    Due to solar radiation effect, current air temperature sensors inside a naturally ventilated radiation shield may produce a measurement error that is 0.8 K or higher. To improve air temperature observation accuracy and correct historical temperature of weather stations, a radiation error correction method is proposed. The correction method is based on a computational fluid dynamics (CFD) method and a genetic algorithm (GA) method. The CFD method is implemented to obtain the radiation error of the naturally ventilated radiation shield under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using the GA method. To verify the performance of the correction equation, the naturally ventilated radiation shield and an aspirated temperature measurement platform are characterized in the same environment to conduct the intercomparison. The aspirated temperature measurement platform serves as an air temperature reference. The mean radiation error given by the intercomparison experiments is 0.23 K, and the mean radiation error given by the correction equation is 0.2 K. This radiation error correction method allows the radiation error to be reduced by approximately 87 %. The mean absolute error and the root mean square error between the radiation errors given by the correction equation and the radiation errors given by the experiments are 0.036 K and 0.045 K, respectively.

  7. Optical CT scanner for in-air readout of gels for external radiation beam 3D dosimetry.

    Science.gov (United States)

    Ramm, Daniel; Rutten, Thomas P; Shepherd, Justin; Bezak, Eva

    2012-06-21

    Optical CT scanners for a 3D readout of externally irradiated radiosensitive hydrogels currently require the use of a refractive index (RI) matching liquid bath to obtain suitable optical ray paths through the gel sample to the detector. The requirement for a RI matching liquid bath has been negated by the design of a plastic cylindrical gel container that provides parallel beam geometry through the gel sample for the majority of the projection. The design method can be used for various hydrogels. Preliminary test results for the prototype laser beam scanner with ferrous xylenol-orange gel show geometric distortion of 0.2 mm maximum, spatial resolution limited to beam spot size of about 0.4 mm and 0.8% noise (1 SD) for a uniform irradiation. Reconstruction of a star pattern irradiated through the cylinder walls demonstrates the suitability for external beam applications. The extremely simple and cost-effective construction of this optical CT scanner, together with the simplicity of scanning gel samples without RI matching fluid increases the feasibility of using 3D gel dosimetry for clinical external beam dose verifications.

  8. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  9. An influential factor for external radiation dose estimation for residents after the Fukushima Daiichi Nuclear Power Plant accident-time spent outdoors for residents in Iitate Village.

    Science.gov (United States)

    Ishikawa, Tetsuo; Yasumura, Seiji; Ohtsuru, Akira; Sakai, Akira; Akahane, Keiichi; Yonai, Shunsuke; Sakata, Ritsu; Ozasa, Kotaro; Hayashi, Masayuki; Ohira, Tetsuya; Kamiya, Kenji; Abe, Masafumi

    2016-06-01

    Many studies have been conducted on radiation doses to residents after the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Time spent outdoors is an influential factor for external dose estimation. Since little information was available on actual time spent outdoors for residents, different values of average time spent outdoors per day have been used in dose estimation studies on the FDNPP accident. The most conservative value of 24 h was sometimes used, while 2.4 h was adopted for indoor workers in the UNSCEAR 2013 report. Fukushima Medical University has been estimating individual external doses received by residents as a part of the Fukushima Health Management Survey by collecting information on the records of moves and activities (the Basic Survey) after the accident from each resident. In the present study, these records were analyzed to estimate an average time spent outdoors per day. As an example, in Iitate Village, its arithmetic mean was 2.08 h (95% CI: 1.64-2.51) for a total of 170 persons selected from respondents to the Basic Survey. This is a much smaller value than commonly assumed. When 2.08 h is used for the external dose estimation, the dose is about 25% (23-26% when using the above 95% CI) less compared with the dose estimated for the commonly used value of 8 h.

  10. Measurements relating fire radiative energy density and surface fuel consumption - RxCADRE 2011 and 2012

    Science.gov (United States)

    Andrew T. Hudak; Matthew B. Dickinson; Benjamin C. Bright; Robert L. Kremens; E. Louise Loudermilk; Joseph J. O' Brien; Benjamin S. Hornsby; Roger D. Ottmar

    2016-01-01

    Small-scale experiments have demonstrated that fire radiative energy is linearly related to fuel combusted but such a relationship has not been shown at the landscape level of prescribed fires. This paper presents field and remotely sensed measures of pre-fire fuel loads, consumption, fire radiative energy density (FRED) and fire radiative power flux density (FRFD),...

  11. Derivation of the radiation budget at ground level from satellite measurements

    Science.gov (United States)

    Raschke, E.

    1982-01-01

    Determination of the Earth radiaton budget and progress in measurement of the budget components and in the treatment of imaging data from satellites are described. Methods for calculating the radiation budget in a general circulation model, radiative transfer characteristics of clouds, computation of solar radiation at ground level using meteorological data and development of a 10-channel radiometer are discussed.

  12. External validation of a normal tissue complication probability model for radiation-induced hypothyroidism in an independent cohort

    DEFF Research Database (Denmark)

    Rønjom, Marianne F; Brink, Carsten; Bentzen, Søren M

    2015-01-01

    BACKGROUND: A normal tissue complication probability (NTCP) model for radiation-induced hypothyroidism (RIHT) was previously derived in patients with squamous cell carcinoma of the head and neck (HNSCC) discerning thyroid volume (Vthyroid), mean thyroid dose (Dmean), and latency as predictive...

  13. Comparing Environmental Dose Rate Meters: A Method to Determine Natural and Non-natural Variations in External Radiation Levels

    Energy Technology Data Exchange (ETDEWEB)

    Reinen, A.J.M.; Slaper, H.; Overwater, R.M.W.; Stoop, P

    2000-07-01

    A method is described to determine low excess dose rates from a radiation source in the environment, which are small compared to the natural fluctuations of the background radiation. First a 'virtual reference dose rate meter' is constructed from data of the national monitoring network, to know the natural variations of the background radiation. Results from this virtual monitor are then compared to data of dose rate meters at sites of interest, to determine non-natural or very local natural variations and excess dose rates. Daily averaged excess dose rates down to 2 to 3 nSv.h{sup -1} can be identified. The method is applied successfully near nuclear installations in the Netherlands and can be used for all types of dose rate meters and sample frequencies. Finally, the calculations to derive the 'virtual reference dose rate meter' can also be used as a quality assessment tool for environmental radiation monitoring networks. (author)

  14. Integration of FDG-PET/CT into external beam radiation therapy planning Technical aspects and recommendations on methodological approaches

    NARCIS (Netherlands)

    Thorwarth, D.; Beyer, T.; Boellaard, R.; De Ruysscher, D.; Grgic, A.; Lee, J. A.; Pietrzyk, U.; Sattler, B.; Schaefer, A.; van Elmpt, W.; Vogel, W.; Oyen, W. J. G.; Nestle, U.

    2012-01-01

    This work addresses the clinical adoption of FDG-PET/CT for image-guided radiation therapy planning (RIP). As such, important technical and methodological aspects of PET/CT-based RIP are reviewed and practical recommendations are given for routine patient management and clinical studies. First, rece

  15. Integration of FDG-PET/CT into external beam radiation therapy planning. Technical aspects and recommendations on methodological approaches.

    NARCIS (Netherlands)

    Thorwarth, D.; Beyer, T.; Boellaard, R.; Ruysscher, D. de; Grgic, A.; Lee, J.A.; Pietrzyk, U.; Sattler, B.; Schaefer, A.; Elmpt, W. van; Vogel, W.; Oyen, W.J.G.; Nestle, U.

    2012-01-01

    This work addresses the clinical adoption of FDG-PET/CT for image-guided radiation therapy planning (RTP). As such, important technical and methodological aspects of PET/CT-based RTP are reviewed and practical recommendations are given for routine patient management and clinical studies. First, rece

  16. Impact of Scattered Radiation onTestosterone Deficiency and MaleHypogonadism in Rectal Cancer Treatedwith External Beam Pelvic Irradiation

    Directory of Open Access Journals (Sweden)

    Halimeh Khatoon Ahmadi

    2010-07-01

    Full Text Available Background: We performed a prospective study to evaluate the effects of pelvic irradiation on FSH, LH and testosterone levels in male patients with rectal adenocarcinoma. Our aim was to compare the level of male sex hormones in peripheral blood serum before and after pelvic irradiation.Methods:The eligible participants were 40 men with rectal adenocarcinoma who underwent pelvic radiotherapy as part of their treatment for primary tumor, either beforeor after surgery. All patients received a 50-Gy radiation dose to the pelvis, 2 Gy perfraction, five days per week. Blood was sampled three times during the study: once before radiation, at the end of the radiation course and 4 to 6 weeks after radiotherapy.Results:Median age of the patients was 58 years (range 18-82. The mean testis dose of radiation per fraction in all 40 patients was 16.3 cGy with a standard deviation of 15.22 (range 5.5-64.8. Serum levels of FSH revealed a significant increase from 7.5 ± 1.7 IU/L(before treatment to 20.9 ± 17.8 IU/L[end of radiotherapy (P<0.001]and 24.1 ± 20.5 IU/L[4 to 6 weeks after radiotherapy (P<0.001]. Serum LH levelswere significantly elevated from 8.04 ± 1.2 IU/L before radiation to 11.6 ± 11.5 IU/Lat the end of radiotherapy (P<0.001 and 12.5 ± 9.9 IU/L4 to 6 weeks after the final course of radiotherapy (P<0.001. There was a decrease in serum testosterone from5.3±2.1 ng/mL before radiation to 4.2 ± 1.9 ng/mLat the end of radiotherapy (P=0.004and 4.5 ± 2 ng/mL4 to 6 weeks after radiotherapy (P=0.035. No significant correlation was seen between age and differences in sex hormones (LH, P=0.605; FSH, P=0.380;testosterone,P=0.161.Conclusion:There was a significant change in serum levels of male sex hormones after pelvic irradiation for rectal cancer (total dose, 50 Gy that indicates considerable testicular damage under these circumstances. Thus, it seems logical to use techniques that reduce the radiation dose to the testicles and to consider the

  17. External Beam Therapy (EBT)

    Science.gov (United States)

    ... Esophageal Cancer Treatment Head and Neck Cancer Treatment Lung Cancer Treatment Prostate Cancer Treatment Brain Tumor Treatment Why is ... Radiation Oncology) Breast Cancer Treatment Esophageal Cancer Treatment Lung Cancer Treatment Images related to External Beam Therapy (EBT) Sponsored ...

  18. Solar Radiation Measurement Using Raspberry Pi and Its Modelling Using Artificial Neural Networks

    OpenAIRE

    Priya Selvanathan Shanmuga; Freudenberg Norman Carl; Borkataky Arunabh

    2016-01-01

    The advent of solar energy as the best alternative to traditional energy sources has led to an extensive study on the measurement and prediction of solar radiation. Devices such as pyranometer, pyrrheliometer, global UV radiometer are used for the measurement of solar radiation. The solar radiation measuring instruments available at Innovation Center, MIT Manipal were integrated with a Raspberry Pi to allow remote access to the data through the university Local Area Network. The connections o...

  19. Analysis of the Stability of External-Application Dermatologic Preparations: Consideration from Rheological Measurements.

    Science.gov (United States)

    Yamamoto, Yoshihisa; Kumetani, Moemi; Onuki, Yoshinori; Koide, Tatsuo; Suzuki, Toyofumi; Fukami, Toshiro

    2016-07-01

    The present study examined the stability of mixtures of various combinations of moisturizers, water in oil (w/o)-type or oil in water (o/w)-type cream preparations containing heparinoids, and steroidal ointments or creams (o/w-type) frequently used in children. Centrifugation at room temperature led to separation of mixtures of w/o-type moisturizers and steroidal ointments into three layers. Polarized microscopic observations, near-infrared (NIR) spectroscopy, and dye-based analyses revealed the presence of oily components in the upper and middle layers and water-soluble components in the lower layer. Separation into three layers upon centrifugation was also observed for mixtures of o/w-type moisturizers and steroidal ointments. In contrast, neither the o/w-type moisturizer and steroidal cream nor the w/o-type moisturizer and steroidal cream mixtures separated into layers upon centrifugation. Consideration of the characteristics of each preparation is necessary when mixing external-application dermatologic preparations. Centrifugation at 4°C did not result in layer separation of the w/o-type moisturizer and steroidal ointment mixture, suggesting that cold storage of such mixtures provides superior stability compared with room temperature storage. However, despite no obvious layer separation, the NIR spectra indicated that water movement was induced within the mixture. These results clearly indicate that methods such as NIR spectroscopy are useful for early determinations of the stability of mixed external-application dermatologic preparations.

  20. Lauriston S. Taylor Lecture on radiation protection and measurements: what makes particle radiation so effective?

    Science.gov (United States)

    Blakely, Eleanor A

    2012-11-01

    The scientific basis for the physical and biological effectiveness of particle radiations has emerged from many decades of meticulous basic research. A diverse array of biologically relevant consequences at the molecular, cellular, tissue, and organism level have been reported, but what are the key processes and mechanisms that make particle radiation so effective, and what competing processes define dose dependences? Recent studies have shown that individual genotypes control radiation-regulated genes and pathways in response to radiations of varying ionization density. The fact that densely ionizing radiations can affect different gene families than sparsely ionizing radiations, and that the effects are dose- and time-dependent, has opened up new areas of future research. The complex microenvironment of the stroma and the significant contributions of the immune response have added to our understanding of tissue-specific differences across the linear energy transfer (LET) spectrum. The importance of targeted versus nontargeted effects remains a thorny but elusive and important contributor to chronic low dose radiation effects of variable LET that still needs further research. The induction of cancer is also LET-dependent, suggesting different mechanisms of action across the gradient of ionization density. The focus of this 35th Lauriston S. Taylor Lecture is to chronicle the step-by-step acquisition of experimental clues that have refined our understanding of what makes particle radiation so effective, with emphasis on the example of radiation effects on the crystalline lens of the human eye.

  1. THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS.There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.

  2. The Atmospheric Radiation Measurement Program May 2003 Intensive Operations Period Examining Aerosol Properties and Radiative Influences: Preface to Special Section

    Science.gov (United States)

    Ferrare, Richard; Feingold, Graham; Ghan, Steven; Ogren, John; Schmid, Beat; Schwartz, Stephen E.; Sheridan, Pat

    2006-01-01

    Atmospheric aerosols influence climate by scattering and absorbing radiation in clear air (direct effects) and by serving as cloud condensation nuclei, modifying the microphysical properties of clouds, influencing radiation and precipitation development (indirect effects). Much of present uncertainty in forcing of climate change is due to uncertainty in the relations between aerosol microphysical and optical properties and their radiative influences (direct effects) and between microphysical properties and their ability to serve as cloud condensation nuclei at given supersaturations (indirect effects). This paper introduces a special section that reports on a field campaign conducted at the Department of Energy Atmospheric Radiation Measurement site in North Central Oklahoma in May, 2003, examining these relations using in situ airborne measurements and surface-, airborne-, and space-based remote sensing.

  3. Calibrated, multiband radiometric measurements of the optical radiation from lightning

    Science.gov (United States)

    Quick, Mason G.

    Calibrated, multiband radiometric measurements of the optical radiation emitted by rocket-triggered lightning (RTL) have been made in the ultraviolet (UV, 200-360 nm), the visible and near infrared (VNIR, 400-1000 nm), and the long wave infrared (LWIR, 8-12 microm) spectral bands. Measurements were recorded from a distance of 198 m at the University of Florida International Center for Lightning Research and Testing (ICLRT) during the summers of 2011 and 2012. The ICLRT provided time-correlated measurements of the current at the base of the RTL channels. Following the onset of a return stroke, the dominant mechanism for the initial rise of the UV and VNIR waveforms was the geometrical growth of the channel in the field-of-view of the sensors. The UV emissions peaked about 0.7 micros after the current peak, with a peak spectral power emitted by the source per unit length of channel of 10 +/- 7 kW/(nm-m) in the UV. The VNIR emissions peaked 0.9 micros after the current peak, with a spectral power of at 7 +/- 4 kW/(nm-m). The LWIR emissions peaked 30-50 micros after the current peak, and the mean peak spectral power was 940 +/- 380 mW/(nm-m), a value that is about 4 orders of magnitude lower than the other spectral band emissions. In some returns strokes the LWIR peak coincides with a secondary maximum in the VNIR band that occurs during a steady decrease in channel current. Examples of the optical waveforms in each spectral band are shown as a function of time and are discussed in the context of the current measured at the channel base. Source power estimates in the VNIR band have a mean and standard deviation of 2.5 +/- 2.2 MW/m and are in excellent agreement with similar estimates of the emission from natural subsequent strokes that remain in a pre-existing channel which have a mean and standard deviation of 2.3 +/- 3.4 MW/m. The peak optical power emitted by RTL in the UV and VNIR bands are observed to be proportional to the square of the peak current at the

  4. Quantitative measurement of radiation pressure on a microcantilever in ambient environment

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Dakang; Munday, Jeremy N., E-mail: jnmunday@umd.edu [Department of Electrical and Computer Engineering, University of Maryland, College Park, Maryland 20742 (United States); Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, Maryland 20742 (United States); Garrett, Joseph L. [Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, Maryland 20742 (United States); Department of Physics, University of Maryland, College Park, Maryland 20742 (United States)

    2015-03-02

    Light reflected off a material or absorbed within it exerts radiation pressure through the transfer of momentum. Micro/nano-mechanical transducers have become sensitive enough that radiation pressure can influence these systems. However, photothermal effects often accompany and overwhelm the radiation pressure, complicating its measurement. In this letter, we investigate the radiation force on an uncoated silicon nitride microcantilever in ambient conditions. We identify and separate the radiation pressure and photothermal forces through an analysis of the cantilever's frequency response. Further, by working in a regime where radiation pressure is dominant, we are able to accurately measure the radiation pressure. Experimental results are compared to theory and found to agree within the measured and calculated uncertainties.

  5. Radiation exposure in nuclear medicine: real-time measurement

    Directory of Open Access Journals (Sweden)

    Iara Sylvain

    2002-09-01

    Full Text Available French regulations have introduced the use of electronic dosimeters for personal monitoring of workers. In order to evaluate the exposure from diagnostic procedures to nuclear medicine staff, individual whole-body doses were measured daily with electronic (digital personal dosimeters during 20 consecutive weeks and correlated with the work load of each day. Personal doses remained always below 20 µSv/d under normal working conditions. Radiation exposure levels were highest to tech staff, nurses and stretcher-bearers. The extrapolated annual cumulative doses for all staff remained less than 10 % of the maximum legal limit for exposed workers (2 mSv/yr. Electronic dosimeters are not technically justified for routine survey of staff. The high sensitivity and immediate reading of electronic semiconductor dosimeters may become very useful for exposure control under risky working conditions. It may become an important help for optimising radiation protection.A legislação francesa introduziu o uso de dosímetros eletrônicos para monitoração da exposição do trabalhador. Afim de avaliar a exposição do trabalhador proveniente de exames diagnósticos em medicina nuclear, doses individuais do corpo inteiro foram medidas diariamente com dosímetros eletrônicos (digitais durante 20 semanas consecutivas e correlatas com as atividades de trabalho de cada dia. As doses foram sempre inferiores à 20 µSv por dia em condições normais de trabalho. Os níveis de exposição de radiação mais elevados foram para os enfermeiros, manipuladores e maqueiros. A extrapolação da dose anual para todos os trabalhadores foi menos que 10 % do limite máximo legal para os trabalhadores expostos (2 mSv/ano. Dosímetros eletrônicos não são tecnicamente justificados para a o controle de rotina da exposição dos trabalhadores, mas a alta sensibilidade e a leitura imediata desses dosímetros podem vir a serem muito úteis para o controle da exposição em condi

  6. Predicting Overall Survival After Stereotactic Ablative Radiation Therapy in Early-Stage Lung Cancer: Development and External Validation of the Amsterdam Prognostic Model

    Energy Technology Data Exchange (ETDEWEB)

    Louie, Alexander V., E-mail: Dr.alexlouie@gmail.com [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Department of Radiation Oncology, London Regional Cancer Program, University of Western Ontario, London, Ontario (Canada); Department of Epidemiology, Harvard School of Public Health, Harvard University, Boston, Massachusetts (United States); Haasbeek, Cornelis J.A. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Mokhles, Sahar [Department of Cardio-Thoracic Surgery, Erasmus University Medical Center, Rotterdam (Netherlands); Rodrigues, George B. [Department of Radiation Oncology, London Regional Cancer Program, University of Western Ontario, London, Ontario (Canada); Stephans, Kevin L. [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Lagerwaard, Frank J. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Palma, David A. [Department of Radiation Oncology, London Regional Cancer Program, University of Western Ontario, London, Ontario (Canada); Videtic, Gregory M.M. [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Warner, Andrew [Department of Radiation Oncology, London Regional Cancer Program, University of Western Ontario, London, Ontario (Canada); Takkenberg, Johanna J.M. [Department of Cardio-Thoracic Surgery, Erasmus University Medical Center, Rotterdam (Netherlands); Reddy, Chandana A. [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Maat, Alex P.W.M. [Department of Cardio-Thoracic Surgery, Erasmus University Medical Center, Rotterdam (Netherlands); Woody, Neil M. [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Slotman, Ben J.; Senan, Suresh [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)

    2015-09-01

    Purpose: A prognostic model for 5-year overall survival (OS), consisting of recursive partitioning analysis (RPA) and a nomogram, was developed for patients with early-stage non-small cell lung cancer (ES-NSCLC) treated with stereotactic ablative radiation therapy (SABR). Methods and Materials: A primary dataset of 703 ES-NSCLC SABR patients was randomly divided into a training (67%) and an internal validation (33%) dataset. In the former group, 21 unique parameters consisting of patient, treatment, and tumor factors were entered into an RPA model to predict OS. Univariate and multivariate models were constructed for RPA-selected factors to evaluate their relationship with OS. A nomogram for OS was constructed based on factors significant in multivariate modeling and validated with calibration plots. Both the RPA and the nomogram were externally validated in independent surgical (n=193) and SABR (n=543) datasets. Results: RPA identified 2 distinct risk classes based on tumor diameter, age, World Health Organization performance status (PS) and Charlson comorbidity index. This RPA had moderate discrimination in SABR datasets (c-index range: 0.52-0.60) but was of limited value in the surgical validation cohort. The nomogram predicting OS included smoking history in addition to RPA-identified factors. In contrast to RPA, validation of the nomogram performed well in internal validation (r{sup 2}=0.97) and external SABR (r{sup 2}=0.79) and surgical cohorts (r{sup 2}=0.91). Conclusions: The Amsterdam prognostic model is the first externally validated prognostication tool for OS in ES-NSCLC treated with SABR available to individualize patient decision making. The nomogram retained strong performance across surgical and SABR external validation datasets. RPA performance was poor in surgical patients, suggesting that 2 different distinct patient populations are being treated with these 2 effective modalities.

  7. Radiation Protection in Educational Institutions. Recommendations of the National Council on Radiation Protection and Measurements.

    Science.gov (United States)

    National Council on Radiation Protection and Measurements, Washington, DC.

    The problems involved when radiation-producing devices of our contemporary technology are used in the teaching of science at the high school and undergraduate college level are discussed. Information is provided on the hazards involved in the use of radiation-producing equipment or radioactive materials in science demonstrations and experiments…

  8. The assessment of four different correction models applied to the diffuse radiation measured with a shadow ring using global and normal beam radiation measurements for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Kudish, Avraham I.; Evseev, Efim G. [Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, E D Bergmann Campus, Beer Sheva 84105 (Israel)

    2008-02-15

    The measurement of the diffuse radiation incident on a horizontal surface, a priori a straightforward task, is fraught with difficulties. It is possible to measure the diffuse radiation by three different techniques: two of which measure it directly and the third indirectly. The most accurate is the indirect one, which is based upon the concurrent measurements of the horizontal global and the normal incidence beam radiation. The disadvantage of this being the relatively expensive tracking system required for measuring the latter. The diffuse radiation can be measured directly with a pyranometer outfitted with either an occulting disk or shadow ring, which prevent the beam radiation from impinging on the pyranometer sensor. The occulting disk can provide accurate measurements of the diffuse radiation but it requires a relatively expensive sun tracking system in the east-west axis. The shadow ring is a stationary device with regard to the east-west axis and blocks the beam radiation component by creating a permanent shadow on the pyranometer sensor. The major disadvantage of the shadow ring is that it also blocks that portion of the diffuse radiation obscured by the shadow ring. This introduces a measurement error that must be corrected to account for that portion of the sky obscured by the shadow band. In addition to this geometric correction factor there is a need to correct for anisotropic sky conditions. Four correction models have been applied to the data for Beer Sheva, Israel and the results have been evaluated both graphically and statistically. An attempt has been made to score the relative performance of the models under different sky conditions. (author)

  9. Normal tissue tolerance to external beam radiation therapy: Skin; Dose de tolerance des tissus sains: la peau et les phaneres

    Energy Technology Data Exchange (ETDEWEB)

    Ginot, A.; Doyen, J.; Hannoun-Levi, J.M.; Courdi, A. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France)

    2010-07-15

    Acute skin toxicity is frequent during radiation therapy and can lead to temporary arrest of the treatment. Chronic toxicity can occur and conduct to cosmetic problems. Alopecia is the most frequent toxicity concerning hair and is most of the time reversible. Several factors linked to patients influence skin toxicity, such as under-nutrition, old age, obesity, smoking, skin diseases, autoimmune diseases, failure of DNA reparation. Skin, hair and nail toxicities depend also on radiation schedule. Acute toxicity is greater when dose per fraction increases. Chronic and acute toxicities are more often when total dose increases. Under 45 Gy, the risk of severe skin toxicity is low, and begins above 50 Gy. Skin toxicity depends also on the duration of radiotherapy and split course schedules are associated with less toxicities. Irradiation surface seems to influence skin toxicity but interaction is more complex. Reirradiation is often feasible in case of cancer recurrence but with a risk of grade 3-4 toxicity above all in head and neck cancer. The benefit/risk ratio has to be always precisely evaluated. Permanent alopecia is correlated with the follicle dose. Modern techniques of radiation therapy allow to spare skin. (authors)

  10. Normal tissue tolerance to external beam radiation therapy: Cardiac structures; Dose de tolerance des tissus sains: le coeur

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France); Giraud, P. [Universite Rene-Descartes Paris 5, 75 - Paris (France); Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, 75 - Paris (France); Belkacemi, Y. [Faculte de medecine de Creteil, universite Paris 12, 94 - Creteil (France); Service d' oncologie-radiotherapie, CHU Henri-Mondor, 94 - Creteil (France)

    2010-07-15

    Radiation thoracic tumors may be associated with cardiac toxicity because of the central position of the heart in the thorax. The present review aims to describe the cardiotoxicity during radiotherapy of different tumor sites most associated with this complication and the risk factors of cardiotoxicity during radiation therapy. Medline literature searches were performed using the following cardiac - heart - radiotherapy - toxicity - cardiotoxicity - breast cancer - lymphoma. Cardiac toxicity after breast cancer and mediastinal lymphoma is the most reported radiation-induced complication. The most frequent clinical complications are pericarditis, congestive heart failure, and heart infarction. These events are mostly asymptomatic. Thus clinicians have to give particular attention to these complications. Anthracycline treatment is a major risk factor for additional cardiotoxicity during radiotherapy with a synergistic effect. Correction of cardiovascular risk is an important point of the prevention of heart complications. Total dose delivered to the planned target volume (PTV), the dose per fraction and the irradiated volume were correlated to the risk of cardiotoxicity. Volume of heart receiving 35 Gy must be inferior to 30% and dose per fraction should not exceed 2 Gy when dose of prescription exceeds 30 Gy. Maximum heart distance (maximal thickness of heart irradiated) must be less than 1 cm during irradiation of breast cancer. Modern irradiation techniques seem to be associated with a limited risk of heart complication. The use of anthracycline, other cardio-toxic chemotherapies and targeted therapies should incite for great caution by performing a careful treatment planning and optimisation. (authors)

  11. Mortality through 1990 among white male workers at the Los Alamos National Laboratory: considering exposures to plutonium and external ionizing radiation.

    Science.gov (United States)

    Wiggs, L D; Johnson, E R; Cox-DeVore, C A; Voelz, G L

    1994-12-01

    A cohort mortality study was conducted of 15,727 white men employed by the Los Alamos National Laboratory, a nuclear research and development facility. Some of the workers at this facility have been exposed to various forms of ionizing radiation and other potentially hazardous materials. These analyses focused on whole-body ionizing radiation exposures and internal depositions of plutonium. The results indicated that overall mortality among this cohort is quite low, even after nearly 30 y of follow-up. No cause of death was significantly elevated among plutonium-exposed workers when compared with their unexposed coworkers; however, a rate ratio for lung cancer of 1.78 (95% CI = 0.79-3.99) was observed. A case of osteogenic sarcoma, a type of cancer related to plutonium exposure in animal studies, was also observed. Dose-response relationships for whole-body dose from external ionizing radiation and tritium were observed for cancers of the brain/central nervous system, the esophagus, and Hodgkin's disease.

  12. Comparison of in vivo translocation frequencies with in vitro G{sub 2} radiosensitivity in radiation workers occupationally exposed to external radiation

    Energy Technology Data Exchange (ETDEWEB)

    Cadwell, Kevin K; Whitehouse, Caroline A; Tawn, E Janet [Westlakes Research Institute, Moor Row, Cumbria, CA24 3JY (United Kingdom); Tarone, Robert E [International Epidemiology Institute, 1455 Research Boulevard, Rockcliffe, MD 20850 (United States)], E-mail: ejtawn@uclan.ac.uk

    2008-03-01

    A group of retired workers from the British Nuclear Fuels plc facility at Sellafield who had been studied for in vivo translocation frequencies in blood lymphocytes were resampled and analysed for in vitro chromosomal radiosensitivity. Significant variation in response to a dose of 0.5 Gy given at the G{sub 2} stage of the cell cycle was observed between individuals (P < 0.001). In a regression analysis that included age, cumulative occupational radiation dose and in vitro G{sub 2} radiation-induced aberration frequencies as independent variables, only cumulative occupational radiation dose had a significant influence on chromosomal translocation frequency (P = 0.0036). G{sub 2} in vitro radiosensitivity is assumed to be a marker for genetic polymorphic variation in DNA damage recognition and repair genes. Therefore, since in vivo translocation frequencies can be considered a surrogate for cancer risk, this lack of association with G{sub 2} in vitro radiosensitivity suggests that such genetic variation has no impact on the response to low dose chronic exposure. (note)

  13. Estimation of delivered doses to the fetus in a external radiation therapy treatment of megavoltage; Estimacion de dosis impartida al feto en un tratamiento de radioterapia externa de megavoltaje

    Energy Technology Data Exchange (ETDEWEB)

    Ruggeri, Ricardo M.; Mairal, Liliana, E-mail: ricardoruggeri@gmail.com [Centro Medico Mevaterapia, Buenos Aires (Argentina); Scarabino, Mara L.; Colombo, Soledad; Sardi, Mabel, E-mail: maliscarabino@gmail.com [Hospital Italiano de Buenos Aires (Argentina)

    2013-11-01

    This work, stimulated by the entrance to our radiotherapy service several cases of central nervous system injury in pregnant patients, involves the estimation of doses to the fetus from the comparative analysis and verification of theoretical and experimental data. Um phantom was designed with the pregnant morphology about 28 weeks gestation, with inserts for waterproof ionization chamber in the head and abdominal area. From the scan of the anthropomorphic phantom were reproduced in 3D planner treatments comprised of pregnant patients, estimating the dose in the lesion and at different points in the abdominal area. With the phantom in the beam of radiation treatment conditions were measured with the camera dose at the same points of the abdomen mentioned and the isocenter of the injury. The dose was also measured on surface of the abdominal area with diode array to establish correlation with the measured dose ionization chamber calibrated with water. The work provided medical radiotherapists fundamental experimental data for elevated risk assessment framework for radiation protection of the fetus. It also set the reference calibration for in vivo dosimetry in the abdominal area in pregnant patients treated for external radiotherapy. The results obtained with the implemented dosimetry design will determine the procedures that will form the operating rules institution and thus how professionals working within it.

  14. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom

    Energy Technology Data Exchange (ETDEWEB)

    Boomsma, Martijn F.; Slouwerhof, Inge; Dalen, Jorn A. van [Isala Hospital, Department of Radiology, Zwolle (Netherlands); Edens, Mireille A. [Isala Hospital, Department of Innovation and Science, Zwolle (Netherlands); Mueller, Dirk [Philips Healthcare systems, Hamburg (Germany); Milles, Julien [Philips Healthcare Benelux, Eindhoven (Netherlands); Maas, Mario [AMC, Department of Radiology, Amsterdam (Netherlands)

    2015-11-15

    The purpose of this research is to study the use of an internal reference standard for fat- and muscle as a replacement for an external reference standard with a phantom. By using a phantomless internal reference standard, Hounsfield unit (HU) measurements of various tissues can potentially be assessed in patients with a CT scan of the pelvis without an added phantom at time of CT acquisition. This paves the way for development of a tool for quantification of the change in tissue density in one patient over time and between patients. This could make every CT scan made without contrast available for research purposes. Fifty patients with unilateral metal-on-metal total hip replacements, scanned together with a calibration reference phantom used in bone mineral density measurements, were included in this study. On computed tomography scans of the pelvis without the use of intravenous iodine contrast, reference values for fat and muscle were measured in the phantom as well as within the patient's body. The conformity between the references was examined with the intra-class correlation coefficient. The mean HU (± SD) of reference values for fat for the internal- and phantom references were -91.5 (±7.0) and -90.9 (±7.8), respectively. For muscle, the mean HU (± SD) for the internal- and phantom references were 59.2 (±6.2) and 60.0 (±7.2), respectively. The intra-class correlation coefficients for fat and muscle were 0.90 and 0.84 respectively and show excellent agreement between the phantom and internal references. Internal references can be used with similar accuracy as references from an external phantom. There is no need to use an external phantom to asses CT density measurements of body tissue. (orig.)

  15. Measurement quantities in radiation protection; Messgroessen im Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosi, Peter [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Fachbereich ' Strahlenschutzdosimetrie' ; Hupe, Oliver [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe ' Photonendosimetrie' ; Kramer, H.M.

    2013-06-15

    After an introduction of the dose equivalent different types of dose equivalents are presented. In this connection stochastic and deterministic radiation effects are considered. Then stationary dose and personnel dose are discussed. Finally the different weighting factors are considered. (HSI)

  16. Automated Radiation Measurements for Aviation Safety (ARMAS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Commercial aircrew members and frequent flyers face radiation hazards from the effects of cosmic rays and solar energetic particles. During significant solar events,...

  17. Measurement of Background Gamma Radiation Levels at Two ...

    African Journals Online (AJOL)

    MICHAEL

    1mSv/annum by International Commission on Radiation Protection [ICRP] for non occupational population ... (such as radon in air) enter inside the body, the body ... particularly along the Niger valley and in most parts .... granite area, Turkey.

  18. Automated Radiation Measurements for Aviation Safety (ARMAS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The existing state-of-the-art for physics-based, data-driven, climatological specification of the global radiation environment is the capability embodied by Nowcast...

  19. New measurements for hadrontherapy and space radiation: biology

    Science.gov (United States)

    Blakely, E. A.

    2001-01-01

    The dual goals of optimizing clinical efficacy of hadrontherapy and determining radiation risk estimates for space research have intersected to a common focus for investigation of the biological effects of charged particles. This paper briefly highlights recent international progress at accelerator facilities engaged in both biological and clinical studies of the effects of particle beams, primarily protons, carbon and iron ions. Basic mechanisms of molecular, cellular and tissue responses continue under investigation for radiations with a range of ionization densities. Late normal tissue effects, including the risk of cancer in particular, are of importance for both research fields. International cooperation has enhanced the rate of progress as evidenced by recent publications. Specific areas of biomedical research related to the biological radiotoxicity of critical organs (especially the central nervous system), individual radiosensitivities to radiation carcinogenesis, and the analysis of effects in mixed radiation fields still require more research. Recommendations for addressing these issues are made.

  20. Lessons learned from the Radiation measurements of the Mars Science Lab Radiation Assessment Detector (MSL-RAD)

    Science.gov (United States)

    Reitz, Guenther; Ottolenghi, Andrea

    2016-07-01

    The Radiation Assessment Detector (RAD) was designed to characterize the radiation environment on the Mars surface and to contribute to an improved assessment of radiation risk for a future human mission to Mars. The flight was chosen to cover a period of solar maximum activity to allow besides the measurement of the galactic cosmic rays an intense study of exposures by solar particle events. The Mars Science Laboratory spacecraft (MSL), containing the Curiosity rover, in which RAD was integrated, was launched to Mars on November 26, 2011. Although not part of the mission planning, RAD was operated already during the 253 day and 560 million km cruise to Mars and made the first time detailed measurements of a radiation environment comparable to that inside a future spacecraft carrying humans to Mars and in other deep space missions. Exactly 100 years after the discovery of cosmic rays on August 7, 1912 RAD makes the first observation of the radiation environment on the surface of another planet and is still gathering data until today. Meanwhile the maximum activity of the current solar cycle has been passed and the solar activity is decreasing. Unfortunately the present solar cycle was an unexpected weak cycle. As a matter of fact only very small solar particle events could be observed during the still ongoing RAD measurements. The paper highlights the achievements of RAD by presenting selected data measured during the cruise and on the Mars surface and describes its impact on predictive models for health risks of astronauts during space missions.

  1. A modified Wheeler cap method for radiation efficiency measurement of balanced electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2010-01-01

    Measurement of radiation efficiency for ultra small antennas represents a great challenge due to influence of the feeding cable. The Wheeler cap method is often used to measure the radiation efficiency of small antennas. However, it is well applicable for antennas on a ground plane, but not for b......Measurement of radiation efficiency for ultra small antennas represents a great challenge due to influence of the feeding cable. The Wheeler cap method is often used to measure the radiation efficiency of small antennas. However, it is well applicable for antennas on a ground plane......, but not for balanced antennas like loops or dipoles. In this paper, a modified Wheeler cap method is proposed for the radiation efficiency measurement of balanced electrically small antennas and a three-port network model of the Wheeler cap measurement is introduced. The advantage of the modified method...

  2. Multi-institutional Prospective Evaluation of Bowel Quality of Life After Prostate External Beam Radiation Therapy Identifies Patient and Treatment Factors Associated With Patient-Reported Outcomes: The PROSTQA Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hamstra, Daniel A., E-mail: dhamm@med.umich.edu [Department of Radiation Oncology, The University of Michigan Medical Center, Ann Arbor, Michigan (United States); Conlon, Anna S.C.; Daignault, Stephanie [Department of Biostatistics, The University of Michigan Comprehensive Cancer Center, Ann Arbor, Michigan (United States); Dunn, Rodney L. [Department of Urology, The University of Michigan Medical Center, Ann Arbor, Michigan (United States); Sandler, Howard M. [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, California (United States); Hembroff, A. Larry [Office for Survey Research, Michigan State University, East Lansing, Michigan (United States); Zietman, Anthony L. [Department of Radiation Oncology, The Massachusetts General Hospital, Boston, Massachusetts (United States); Kaplan, Irving [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Ciezki, Jay [Department of Radiation Oncology, The Cleveland Clinic, Cleveland, Ohio (United States); Kuban, Deborah A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Wei, John T. [Department of Urology, The University of Michigan Medical Center, Ann Arbor, Michigan (United States); Sanda, Martin G. [Department of Urology, Emory University Medical Center, Atlanta, Georgia (United States); Michalski, Jeff M. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States)

    2013-07-01

    Purpose: To evaluate patients treated with external beam radiation therapy as part of the multicenter Prostate Cancer Outcomes and Satisfaction with Treatment Quality Assessment (PROSTQA), to identify factors associated with posttreatment patient-reported bowel health-related quality of life (HRQOL). Methods and Materials: Pretreatment characteristics and treatment details among 292 men were evaluated using a general linear mixed model for their association with measured HRQOL by the Expanded Prostate Cancer Index Composite instrument through 2 years after enrollment. Results: Bowel HRQOL had a median score of 100 (interquartile range 91.7-100) pretreatment and 95.8 (interquartile range 83.3-100) at 2 years, representing new moderate/big problems in 11% for urgency, 7% for frequency, 4% for bloody stools, and 8% for an overall bowel problems. Baseline bowel score was the strongest predictor for all 2-year endpoints. In multivariable models, a volume of rectum ≥25% treated to 70 Gy (V70) yielded a clinically significant 9.3-point lower bowel score (95% confidence interval [CI] 16.8-1.7, P=.015) and predicted increased risks for moderate to big fecal incontinence (P=.0008). No other radiation therapy treatment-related variables influenced moderate to big changes in rectal HRQOL. However, on multivariate analyses V70 ≥25% was associated with increases in small, moderate, or big problems with the following: incontinence (3.9-fold; 95% CI 1.1-13.4, P=.03), rectal bleeding (3.6-fold; 95% CI 1.3-10.2, P=.018), and bowel urgency (2.9-fold; 95% CI 1.1-7.6, P=.026). Aspirin use correlated with a clinically significant 4.7-point lower bowel summary score (95% CI 9.0-0.4, P=.03) and an increase in small, moderate, or big problems with bloody stools (2.8-fold; 95% CI 1.2-6.4, P=.018). Intensity modulated radiation therapy was associated with higher radiation therapy doses to the prostate and lower doses to the rectum but did not independently correlate with bowel HRQOL

  3. A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures

    Science.gov (United States)

    Tian, Qijie; Chang, Songtao; Li, Zhou; He, Fengyun; Qiao, Yanfeng

    2017-03-01

    The suppression level of internal stray radiation is a key criterion for infrared imaging systems, especially for high-precision cryogenic infrared imaging systems. To achieve accurate measurement for internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures, a measurement method, which is based on radiometric calibration, is presented in this paper. First of all, the calibration formula is deduced considering the integration time, and the effect of ambient temperature on internal stray radiation is further analyzed in detail. Then, an approach is proposed to measure the internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures. By calibrating the system under two ambient temperatures, the quantitative relation between the internal stray radiation and the ambient temperature can be acquired, and then the internal stray radiation of the cryogenic infrared imaging system under various ambient temperatures can be calculated. Finally, several experiments are performed in a chamber with controllable inside temperatures to evaluate the effectiveness of the proposed method. Experimental results indicate that the proposed method can be used to measure internal stray radiation with high accuracy at various ambient temperatures and integration times. The proposed method has some advantages, such as simple implementation and the capability of high-precision measurement. The measurement results can be used to guide the stray radiation suppression and to test whether the internal stray radiation suppression performance meets the requirement or not.

  4. External doses from radioactive fallout. Dosimetry and levels

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T.

    1995-12-31

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF{sub 2} with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs.

  5. Mars' surface radiation environment measured with the Mars science laboratory's curiosity rover

    NARCIS (Netherlands)

    Hassler, D.M.; Zeitlin, C.; Wimmer-Schweingruber, R.F.; Ehresmann, B.; Rafkin, S.; Eigenbrode, J.L.; Brinza, D.E.; Weigle, G.; Böttcher, S.; Böhm, E.; Burmeister, S.; Guo, J.; Köhler, J.; Martin, C.; Reitz, G.; Cucinotta, F.A.; Kim, M.-H.; Grinspoon, D.; Bullock, M.A.; Posner, A.; Gómez-Elvira, J.; Vasavada, A.; Grotzinger, J.P.; MSL Science Team, the

    2014-01-01

    The Radiation Assessment Detector (RAD) on the Mars Science Laboratory’s Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose equival

  6. Mars' surface radiation environment measured with the Mars science laboratory's curiosity rover

    NARCIS (Netherlands)

    Hassler, D.M.; Zeitlin, C.; Wimmer-Schweingruber, R.F.; Ehresmann, B.; Rafkin, S.; Eigenbrode, J.L.; Brinza, D.E.; Weigle, G.; Böttcher, S.; Böhm, E.; Burmeister, S.; Guo, J.; Köhler, J.; Martin, C.; Reitz, G.; Cucinotta, F.A.; Kim, M.-H.; Grinspoon, D.; Bullock, M.A.; Posner, A.; Gómez-Elvira, J.; Vasavada, A.; Grotzinger, J.P.; MSL Science Team, the

    2014-01-01

    The Radiation Assessment Detector (RAD) on the Mars Science Laboratory’s Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose equival

  7. The external and internal measurement impact on shear modulus distribution within cyclic small strains in triaxal studies into cohesive soil

    Directory of Open Access Journals (Sweden)

    Jastrzebska M.

    2010-06-01

    Full Text Available The paper deals with comparison of tangent shear moduli Gs of kaolin from Tułowice obtained from cyclic triaxial tests on the basis of external and internal reading in the small strains range (10-5÷10-3. The tests were carried out on a modernised test bed, enabling full saturation of specimens using the back pressure method as well as a precise internal measurement of strains by means of contactless microdisplacements sensors. The value of linearity factor L is one of adopted quality criteria for two measuring methods. Maintaining a constant deformation rate the influence of various cyclic process parameters (deviator stress amplitude – constant or variable; high or low; initial level of stress and strain, at which the unloading and reloading cycles were started; overconsolidation ratio OCR as well as cycles’ number and arrangement on the "shear modulus – axial strain" characteristic was studied. The obtained values of Gint and Gext (or Lint and Lext clearly show an underestimation (even 5 times of Gs value within the range 10-5÷10-3 when using an external measurement. In addition, the differences between Gint and Gext, which develop differently depending on specified cyclic process parameters, gradually decrease with increasing axial strains.

  8. Determination of dose factors for external gamma radiation at residences; Determinacao de fatores de dose para radiacao gama externa em residencias

    Energy Technology Data Exchange (ETDEWEB)

    Maduar, Marcelo Francis; Hiromoto, Goro [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1999-11-01

    A significant contribution to the global population exposure to ionizing radiation arises from natural sources, especially from radionuclides present in terrestrial crust. Human activities can eventually concentrate such radionuclides to significant levels from the point of view of radiological protection. Phosphogypsum, a by product of fertilizers industry, shows radionuclide concentrations in these conditions. Therefore, the viability of its use as an alternative material for natural gypsum in dwellings construction is conditioned, among several additional aspects, to optimization studies. This paper presents a methodology for theoretical evaluation of external gamma doses due to radionuclides present in wall in an hypothetical room constructed of phosphogypsum sheets. Assessment of dose is being carried out through the application of photon transport model, taking into account self-absorption and buildup factors. (author) 10 refs., 2 figs.

  9. Structural transformation of NANOPERM-type metallic glasses followed in situ by synchrotron radiation during thermal annealing in external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Procházka, V., E-mail: v.prochazka@upol.cz [Department of Experimental Physics, Faculty of Science, Palacký University, 17. listopadu 12, 771 46 Olomouc (Czech Republic); Vrba, V.; Smrčka, D. [Department of Experimental Physics, Faculty of Science, Palacký University, 17. listopadu 12, 771 46 Olomouc (Czech Republic); Rüffer, R. [ESRF-The European Synchrotron, CS40220, 38043 Grenoble Cedex 9 (France); Matúš, P. [Institute of Laboratory Research on Geomaterials, Faculty of Natural Sciences, Comenius University, Mlynská dolina, 842 15 Bratislava (Slovakia); Mašláň, M. [Department of Experimental Physics, Faculty of Science, Palacký University, 17. listopadu 12, 771 46 Olomouc (Czech Republic); Miglierini, M.B. [Institute of Nuclear and Physical Engineering, Slovak University of Technology, 812 19 Bratislava (Slovakia); Regional Centre of Advanced Technologies and Materials, Palacký University, 17. listopadu 12, 771 46 Olomouc (Czech Republic)

    2015-07-25

    Highlights: • On-fly inspection of structural transformations during magnetic annealing. • Crystallization starts by ∼100 K earlier during magnetic annealing. • Potential for modification of the material properties using magnetic field. • The whole crystallization process was followed with high time resolution. - Abstract: Kinetics of the crystallization process of Fe–Mo–Cu–B-type metallic glass is studied to fine details during heat treatment under weak external magnetic field (0.652 T). Structural arrangement as well as magnetic microstructure is followed on-fly using sophisticated method of in situ nuclear forward scattering (NFS) of synchrotron radiation. The latter provides both quantitative (relative fractions) and qualitative (hyperfine magnetic fields) temperature dependencies of all structurally different samples’ components. They belong to the amorphous residual matrix, the newly formed nanocrystalline grains, and to their surfaces, respectively. The onset of crystallization during in-field magnetic annealing starts ∼100 K earlier than that in zero field.

  10. A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-Ping; CHEN Zhao-Yang; BA Wei-Zhen; FAN Yan-Wei; DU Yan-Zhao; PAN Shi-Lie; GUO Qi

    2008-01-01

    The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity.Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-acoess and hazardous.In addition.optical fiber dosimeters are immune to electrical and radio-frequency interference.In this paper,a novel remote optical fiber radiation dosimeter is described.The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL.The measuring range of the dosimeter is from 0.1 to 100 Gy.The equipment is relatively simple and small in size,and has low power consumption.This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions.

  11. Radiation dose measurements during kilovoltage-cone beam computed tomography imaging in radiotherapy

    Directory of Open Access Journals (Sweden)

    A Sathish Kumar

    2016-01-01

    Conclusion: Radiation dose to the eye, breast, and the surface of the pelvis have been arrived at during CBCT. The doses measured on patients agreed closely with those measured on humanoid phantom and with published values.

  12. Prevalence and Predicting Factors for Commonly Neglected Sexual Side Effects to External-Beam Radiation Therapy for Prostate Cancer

    DEFF Research Database (Denmark)

    Frey, Anders; Pedersen, Christian; Lindberg, Henriette

    2017-01-01

    INTRODUCTION: Changes in sexual function other than erectile dysfunction are sparsely investigated after radiation therapy for prostate cancer. AIM: To investigate orgasmic dysfunction, urinary incontinence during sexual activity, changes in penile morphology, and sensory disturbances in the penis...... increased. Eleven percent reported anejaculation. Fifteen percent reported orgasm-associated pain. Only 4% reported urinary incontinence during sexual activity. Subjective penile length loss in excess of 1 cm was reported by 42%. Twelve percent reported an altered curvature of their penis after EBRT. Six...... percent reported painful erections. Twenty-seven percent reported decreased sensitivity in the penis after EBRT, 2% reported a cold sensation, and 2% reported paresthesia. Increasing time since final treatment increased the risk of penile sensory disturbances (odds ratio = 1.05; P = .028). CONCLUSION...

  13. Fabrication and Measurement of Precision Structures for External Occulter Optical Edges Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project proposes to develop an occulter optical edge and optical edge measurement verification system suitable for astrophysics missions including JWST and the...

  14. Adaptive Radiation Therapy for Post-Prostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiotherapy

    Science.gov (United States)

    Zhu, Mingyao; Bharat, Shyam; Michalski, Jeff M.; Gay, H; Hou, Wei-Hsien; Parikh, Parag J.

    2012-01-01

    Purpose Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso® 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in post-prostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials Tracking data recorded by Calypso EM transponders was analyzed for post-prostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (Dmin) with the planned Dmin to the CTV. Treatments were considered adequate if the delivered CTV Dmin is at least 95% of the planned CTV Dmin. Results Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: − 0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5 degrees, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion Target rotational motion could cause under-dosage to partial volume of the post-prostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery. PMID:23021439

  15. Stereotactic Ablative Radiosurgery for Locally-Advanced or Recurrent Skull Base Malignancies with Prior External Beam Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Karen Mann Xu

    2015-03-01

    Full Text Available Purpose: Stereotactic ablative radiotherapy (SABR is an attractive modality to treat malignancies invading the skull base as it can deliver a highly conformal dose with minimal toxicity. However, variation exists in the prescribed dose and fractionation. The purpose of our study is to examine the local control, survival and toxicities in SABR for the treatment of malignant skull base tumors. Methods and Materials: A total of 31 patients and 40 locally-advanced or recurrent head and neck malignancies involving the skull base treated with a common SABR regimen which delivers a radiation dose of 44 Gy in 5 fractions from January 1st, 2004 to December 31st, 2013 were retrospectively reviewed. The local control rate (LC, progression-free survival rate (PFS, overall survival rate (OS and toxicities were reported.Results: The median follow-up time of all patients was 11.4 months (range: 0.6-67.2 months. The median tumor volume was 27 cm3 (range: 2.4-205 cm3. All patients received prior EBRT with a median radiation dose of 64 Gy (range: 24-75.6 Gy delivered in 12 to 42 fractions. 20 patients had surgeries prior to SABR. 19 patients received chemotherapy. Specifically, 8 patients received concurrent cetuximab (ErbituxTM with SABR. The median time-to-progression (TTP was 3.3 months (range: 0-16.9 months. For the 29 patients (93.5% who died, the median time from the end of first SABR to death was 10.3 months (range: 0.5-41.4 months. The estimated 1-year overall survival (OS rate was 35%. The estimated 2-year OS rate was 12%. Treatment was well-tolerated without grade 4 or 5 treatment-related toxicities.Conclusions: SABR has been shown to achieve low toxicities in locally-advanced or recurrent, previously irradiated head and neck malignancies invading the skull base.

  16. Measurements of energetic particle radiation in transit to Mars on the Mars Science Laboratory.

    Science.gov (United States)

    Zeitlin, C; Hassler, D M; Cucinotta, F A; Ehresmann, B; Wimmer-Schweingruber, R F; Brinza, D E; Kang, S; Weigle, G; Böttcher, S; Böhm, E; Burmeister, S; Guo, J; Köhler, J; Martin, C; Posner, A; Rafkin, S; Reitz, G

    2013-05-31

    The Mars Science Laboratory spacecraft, containing the Curiosity rover, was launched to Mars on 26 November 2011, and for most of the 253-day, 560-million-kilometer cruise to Mars, the Radiation Assessment Detector made detailed measurements of the energetic particle radiation environment inside the spacecraft. These data provide insights into the radiation hazards that would be associated with a human mission to Mars. We report measurements of the radiation dose, dose equivalent, and linear energy transfer spectra. The dose equivalent for even the shortest round-trip with current propulsion systems and comparable shielding is found to be 0.66 ± 0.12 sievert.

  17. The radiation measurement applied to beam lifetime study on the synchrotron radiation facilities

    Science.gov (United States)

    Li, Yuxiong; Li, Juexin; Liu, Zuping; Cui, Yonggang; Gong, Guanghua; Shao, Beibei

    2003-06-01

    To collect beam loss information from an accelerator radiation field is helpful to machine study and operation. For a synchrotron radiation storage ring, shower electrons give a distinct clue to loss location and a BLM-XS model detector is suitable to detect them. Recently, we set up a new beam loss monitoring system by this method for National Synchrotron Radiation Laboratory (NSRL) storage ring. It does not interfere with the vacuum chamber and machine operation. Different from other systems, the detectors are used in pairs, fixed on opposite sides of the chamber separately. Some interesting phenomena about beam lifetime were observed. We located exactly where an excessive beam loss took place during ramping process and solved the problem. It was proved that gas accumulated at the front ends of photo-beam lines strongly impacted the electron beam and led to beam lifetime decreases. The cause of beam lifetime decrease because of superconducting wiggler is discussed.

  18. An information theory approach for evaluating earth radiation budget (ERB) measurements - Nonuniform sampling of reflected shortwave radiation

    Science.gov (United States)

    Barkstrom, Bruce R.; Direskeneli, Haldun; Halyo, Nesim

    1992-01-01

    An information theory approach to examine the temporal nonuniform sampling characteristics of shortwave (SW) flux for earth radiation budget (ERB) measurements is suggested. The information gain is computed by computing the information content before and after the measurements. A stochastic diurnal model for the SW flux is developed, and measurements for different orbital parameters are examined. The methodology is applied to specific NASA Polar platform and Tropical Rainfall Measuring Mission (TRMM) orbital parameters. The information theory approach, coupled with the developed SW diurnal model, is found to be promising for measurements involving nonuniform orbital sampling characteristics.

  19. Nuclear Technology Series. Course 11: Radiation Detection and Measurement.

    Science.gov (United States)

    Technical Education Research Center, Waco, TX.

    This technical specialty course is one of thirty-five courses designed for use by two-year postsecondary institutions in five nuclear technician curriculum areas: (1) radiation protection technician, (2) nuclear instrumentation and control technician, (3) nuclear materials processing technician, (4) nuclear quality-assurance/quality-control…

  20. Size measurement of radioactive aerosol particles in intense radiation fields using wire screens and imaging plates

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yuichi; Tanaka, Toru; Takamiya, Koichi; Ishi, Yoshihiro; UesugI, Tomonori; Kuriyama, Yasutoshi; Sakamoto, Masaaki; Ohtsuki, Tsutomu [Kyoto University Research Reactor Institute, Osaka (Japan); Nitta, Shinnosuke [Graduate School of Engineering, Kyoto University, Kyoto (Japan); Osada, Naoyuki [Advanced Science Research Center, Okayama University, Okayama (Japan)

    2016-09-15

    Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of 11C-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. The size distribution for 11C-bearing aerosol particles was found to be ca. 70 μm in geometric mean diameter. The size was similar to that for 7Be-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

  1. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles.

    Science.gov (United States)

    Magnusson, Bertil; Ossowicki, Haakan; Rienitz, Olaf; Theodorsson, Elvar

    2012-05-01

    Healthcare laboratories are increasingly joining into larger laboratory organizations encompassing several physical laboratories. This caters for important new opportunities for re-defining the concept of a 'laboratory' to encompass all laboratories and measurement methods measuring the same measurand for a population of patients. In order to make measurement results, comparable bias should be minimized or eliminated and measurement uncertainty properly evaluated for all methods used for a particular patient population. The measurement as well as diagnostic uncertainty can be evaluated from internal and external quality control results using GUM principles. In this paper the uncertainty evaluations are described in detail using only two main components, within-laboratory reproducibility and uncertainty of the bias component according to a Nordtest guideline. The evaluation is exemplified for the determination of creatinine in serum for a conglomerate of laboratories both expressed in absolute units (μmol/L) and relative (%). An expanded measurement uncertainty of 12 μmol/L associated with concentrations of creatinine below 120 μmol/L and of 10% associated with concentrations above 120 μmol/L was estimated. The diagnostic uncertainty encompasses both measurement uncertainty and biological variation, and can be estimated for a single value and for a difference. This diagnostic uncertainty for the difference for two samples from the same patient was determined to be 14 μmol/L associated with concentrations of creatinine below 100 μmol/L and 14 % associated with concentrations above 100 μmol/L.

  2. Radiation damage measurements on CZT drift strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kuvvetli, I. E-mail: irfan@dsri.dk; Budtz-Joergensen, C. E-mail: carl@dsri.dk; Korsbech, U.; Jensen, H.J

    2003-10-11

    At DSRI, in collaboration with the cyclotron facility at Copenhagen University Hospital, we have performed a study of radiation effects exposing a 2.7 mm thick CZT drift strip detector to 30 MeV protons. The detector characteristics were evaluated after exposure to a number of fluences in the range from 2x10{sup 8} to 60x10{sup 8} p{sup +}/cm{sup 2}. Even for the highest fluences, which had a dramatic effect on the spectroscopic performance, we were able to recover the detectors after an appropriate annealing procedure. The radiation damage was studied as a function of depth inside the detector material. A numerical model that emulates the physical processes of the charge transport in the CZT detector was used to derive the charge trapping parameter, {mu}{tau}{sub e} (the product of charge mobility and trapping time) as a function of fluence. The analysis showed that the electron trapping increased proportionately with the proton dose. The radiation contribution to the electron trapping was found to obey the following relation: ({mu}{tau}{sub e}{sup -1}){sub rad}=(2.5{+-}0.2)x10{sup -7}xPHI (V/cm){sup 2} with the proton fluence, PHI in p{sup +}/cm{sup 2}. The trapping depth dependence, however, did not agree well with the damage profile calculated using the standard Monte Carlo simulations, TRIM , for the proton-induced radiation effects. The present results suggest that proton-induced nuclear reactions contribute significantly to the radiation damage. Further work will elaborate on these effects.

  3. Radiation damage measurements on CZT drift strip detectors

    Science.gov (United States)

    Kuvvetli, I.; Budtz-Jørgensen, C.; Korsbech, U.; Jensen, H. J.

    2003-10-01

    At DSRI, in collaboration with the cyclotron facility at Copenhagen University Hospital, we have performed a study of radiation effects exposing a 2.7 mm thick CZT drift strip detector to 30 MeV protons. The detector characteristics were evaluated after exposure to a number of fluences in the range from 2×10 8 to 60×10 8 p +/cm 2. Even for the highest fluences, which had a dramatic effect on the spectroscopic performance, we were able to recover the detectors after an appropriate annealing procedure. The radiation damage was studied as a function of depth inside the detector material. A numerical model that emulates the physical processes of the charge transport in the CZT detector was used to derive the charge trapping parameter, μτe (the product of charge mobility and trapping time) as a function of fluence. The analysis showed that the electron trapping increased proportionately with the proton dose. The radiation contribution to the electron trapping was found to obey the following relation: (μτ e- 1) rad=(2.5±0.2)×10 -7×Φ ( V/cm)2 with the proton fluence, Φ in p +/cm 2. The trapping depth dependence, however, did not agree well with the damage profile calculated using the standard Monte Carlo simulations, TRIM [1], for the proton-induced radiation effects. The present results suggest that proton-induced nuclear reactions contribute significantly to the radiation damage. Further work will elaborate on these effects.

  4. Does response distortion statistically affect the relations between self-report psychopathy measures and external criteria?

    NARCIS (Netherlands)

    A.L. Watts; S.O. Lilienfeld; J.F. Edens; K.S. Douglas; J.L. Skeem; B. Verschuere; A.C. LoPilato

    2015-01-01

    Given that psychopathy is associated with narcissism, lack of insight, and pathological lying, the assumption that the validity of self-report psychopathy measures is compromised by response distortion has been widespread. We examined the statistical effects (moderation, suppression) of response dis

  5. Use of Plant Hydrocarbons as External Markers to Measure Voluntary Intake and Digestibility in Beef Steers

    Science.gov (United States)

    Calculating dry matter intake of grazing herbivores has been an issue in determining factors such as efficiency and digestibility of forages. Two experiments were conducted using alkanes to validate analytical methods with oven-dried and freeze-dried samples, to compare and contrast measured and pre...

  6. Does response distortion statistically affect the relations between self-report psychopathy measures and external criteria?

    NARCIS (Netherlands)

    Watts, A.L.; Lilienfeld, S.O.; Edens, J.F.; Douglas, K.S.; Skeem, J.L.; Verschuere, B.; LoPilato, A.C.

    2016-01-01

    Given that psychopathy is associated with narcissism, lack of insight, and pathological lying, the assumption that the validity of self-report psychopathy measures is compromised by response distortion has been widespread. We examined the statistical effects (moderation, suppression) of response dis

  7. Does response distortion statistically affect the relations between self-report psychopathy measures and external criteria?

    NARCIS (Netherlands)

    Watts, A.L.; Lilienfeld, S.O.; Edens, J.F.; Douglas, K.S.; Skeem, J.L.; Verschuere, B.; LoPilato, A.C.

    2016-01-01

    Given that psychopathy is associated with narcissism, lack of insight, and pathological lying, the assumption that the validity of self-report psychopathy measures is compromised by response distortion has been widespread. We examined the statistical effects (moderation, suppression) of response dis

  8. Airborne spectral radiation measurements to derive solar radiative forcing of Saharan dust mixed with biomass burning smoke particles

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, S.; Bierwirth, E.; Wendisch, M. (Leipzig Inst. for Meteorology (LIM), Univ. of Leipzig, Leipzig (Germany)), e-mail: s.bauer@uni-leipzig.de; Esselborn, M.; Petzold, A.; Trautmann, T. (Deutsches Zentrum fur Luft- und Raumfahrt (DLR), Oberpfaffenhofen (Germany)); Macke, A. (Leibniz Inst. for Tropospheric Research (IfT) (Germany))

    2011-09-15

    Airborne measurements of upward solar spectral irradiances were performed during the second Saharan Mineral dUst experiMent (SAMUM-2) campaign based on the Cape Verde Islands. Additionally, airborne high resolution lidar measurements of vertical profiles of particle extinction coefficients were collected in parallel to the radiation data. Aerosol layers of Saharan dust, partly mixed with biomass-burning smoke, were probed. With corresponding radiative transfer simulations the single scattering albedo and the asymmetry parameter of the aerosol particles were derived although with high uncertainty. The broad-band aerosol solar radiative forcing at the top of atmosphere was calculated and examined as a function of the aerosol types. However, due to uncertainties in both the measurements and the calculations the chemical composition cannot be identified. In addition, a mostly measurement-based method to derive the broad-band aerosol solar radiative forcing was used. This approach revealed clear differences of broad-band net irradiances as a function of the aerosol optical depth. The data were used to identify different aerosol types from different origins. Higher portions of biomass-burning smoke lead to larger broad-band net irradiances

  9. State-of-the-art of external photon beam radiation treatment planning. Photon Treatment Planning Collaborative Working Group.

    Science.gov (United States)

    1991-05-15

    A virtual revolution in computer capability has occurred in the last few years, largely based on rapidly decreasing costs and increasing reliability of digital memory and mass-storage capability. These developments have now made it possible to consider the application of both computer and display technologies to a much broader range of problems in radiation therapy, including planning of treatment, dose computation, and treatment verification. Several methods of three-dimensional dose computations in heterogeneous media capable of 3% accuracy are likely to be available, but significant work still remains, particularly for high energy x-rays where electron transport, and possibly pair production, need to be considered. Innovative display and planning techniques, as well as plan evaluation schemes, are emerging and show great promise for the future. No doubt these advances will lead to substantially improved treatment planning systems in the next few years. However, it must be emphasized that for many of these applications a tremendous software and hardware development effort is required.

  10. Data management and scientific integration within the Atmospheric Radiation Measurement Program

    Science.gov (United States)

    Gracio, Deborah K.; Hatfield, Larry D.; Yates, Kenneth R.; Voyles, Jimmy W.; Tichler, Joyce L.; Cederwall, Richard T.; Laufersweiler, Mark J.; Leach, Martin J.; Singley, Paul

    1995-01-01

    The Atmospheric Radiation Measurement (ARM) Program has been developed by the U.S. Department of Energy with the goal to improve the predictive capabilities of General Circulation Models (GCM's) in their treatment of clouds and radiative transfer effects. To achieve this goal, three experimental testbeds were designed for the deployment of instruments that will collect atmospheric data used to drive the GCM's. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in September 1995 in the Tropical Western Pacific and in 1997 on the North Slope of Alaska. Approximately 400 MB of data are transferred per day via the Internet from the SGP site to the ARM Experiment Center at Pacific Northwest Laboratory in Richland, Washington. The Experiment Center is central to the ARM data path and provides for the collection, processing, analysis, and delivery of ARM data. Data are received from the CART sites from a variety of instrumentation, observational systems, amd external data sources. The Experiment Center processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while providing a three-month running archive of data. A primary requirement of the ARM Program is to preserve and protect all data produced or acquired. This function is performed at Oak Ridge National Laboratory where leading edge technology is employed for the long-term storage of ARM data. The ARM Archive provides access to data for participation outside of the ARM Program. The ARM Program involves a collaborative effort by teams from various DOE National Laboratories, providing multi-disciplinary areas of expertise. This paper will discuss the collaborative methods in which the ARM teams

  11. Comparison of Martian Surface Radiation Predictions to the Measurements of Mars Science Laboratory Radiation Assessment Detector (MSL/RAD)

    Science.gov (United States)

    Kim, Myung-Hee Y.; Cucinotta, Francis A.; Zeitlin, Cary; Hassler, Donald M.; Ehresmann, Bent; Rafkin, Scot C. R.; Wimmer-Schweingruber, Robert F; Boettcher, Stephan; Boehm, Eckart; Guo, Jingnan; hide

    2014-01-01

    For the analysis of radiation risks to astronauts and planning exploratory space missions, detailed knowledge of particle spectra is an important factor. Detailed measurements of the energetic particle radiation environment on the surface of Mars have been made by the Mars Science Laboratory Radiation Assessment Detector (MSL-RAD) on the Curiosity rover since August 2012, and particle fluxes for a wide range of ion species (up to several hundred MeV/u) and high energy neutrons (8 - 1000 MeV) have been available for the first 200 sols. Although the data obtained on the surface of Mars for 200 sols are limited in the narrow energy spectra, the simulation results using the Badhwar-O'Neill galactic cosmic ray (GCR) environment model and the high-charge and energy transport (HZETRN) code are compared to the data. For the nuclear interactions of primary GCR through Mars atmosphere and Curiosity rover, the quantum multiple scattering theory of nuclear fragmentation (QMSFRG) is used, which includes direct knockout, evaporation and nuclear coalescence. Daily atmospheric pressure measurements at Gale Crater by the MSL Rover Environmental Monitoring Station are implemented into transport calculations for describing the daily column depth of atmosphere. Particles impinging on top of the Martian atmosphere reach the RAD after traversing varying depths of atmosphere that depend on the slant angles, and the model accounts for shielding of the RAD by the rest of the instrument. Calculations of stopping particle spectra are in good agreement with the RAD measurements for the first 200 sols by accounting changing heliospheric conditions and atmospheric pressure. Detailed comparisons between model predictions and spectral data of various particle types provide the validation of radiation transport models, and thus increase the accuracy of the predictions of future radiation environments on Mars. These contributions lend support to the understanding of radiation health risks to

  12. A modified Wheeler cap method for radiation efficiency measurement of balanced electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2010-01-01

    , but not for balanced antennas like loops or dipoles. In this paper, a modified Wheeler cap method is proposed for the radiation efficiency measurement of balanced electrically small antennas and a three-port network model of the Wheeler cap measurement is introduced. The advantage of the modified method......Measurement of radiation efficiency for ultra small antennas represents a great challenge due to influence of the feeding cable. The Wheeler cap method is often used to measure the radiation efficiency of small antennas. However, it is well applicable for antennas on a ground plane...... is that it is wideband, thus does not require any balun, and both the antenna input impedance and radiation efficiency can be obtained. An electrically small loop antenna and a wideband dipole were simulated and measured according to the proposed method and the results of measurements and simulations are presented...

  13. A novel dosimeter for measuring the amount of radiation exposure of surgeons during percutaneous nephrolithotomy: Instadose™

    Science.gov (United States)

    Yuruk, Emrah; Gureser, Gokhan; Tuken, Murat; Ertas, Kasim

    2016-01-01

    Introduction The aim of this study was to demonstrate the efficacy of Instadose™, a novel dosimeter designed for radiation workers to provide a measurement of the radiation dose at any time from any computer; to determine the amount of radiation exposure during percutaneous nephrolithotomy (PNL); and to evaluate the factors that affect the amount of radiation exposed. Material and methods Two experienced surgeons wore Instadose™ on the outer part of their lead aprons during the PNL procedures performed between December 2013 and July 2014. Patient demographics and stone characteristics were noted. Factors affecting radiation dose were determined. Fluoroscopic screening time was compared with the amount of radiation in order to validate the measurements of Instadose™. Results Overall, 51 patients with a mean age of 43.41 ±18.58 (range 1–75) years were enrolled. Male to female ratio was 35/16. The amount of radiation was greater than 0.01mSv in only 19 (37.25%) cases. Stone location complexity (p = 0.380), dilation type (p = 0.584), stone size (p = 0.565), dilation size (p = 0.891) and access number (p = 0.268) were not associated with increased radiation exposure. Instadose™ measurements were correlated with fluoroscopic screening time (r = 0.519, p = 0.001). Conclusions Instadose™ is a useful tool for the measurement of radiation exposure during PNL. The advantage of measuring the amount of radiation exposure after each PNL operation is that it may aid urologists in taking appropriate precautions to minimize the risk of radiation related complications. PMID:27551558

  14. 60 GHz antenna measurement setup using a VNA without external frequency conversion

    DEFF Research Database (Denmark)

    Popa, Paula Irina; Pivnenko, Sergey; Nielsen, Jeppe Majlund;

    2014-01-01

    and phase, 0.06 dB and 6 degrees peak-to-peak deviations over 4 hours. A PNF measurement of a 25 dBi Standard Gain Horn was carried out and the results were compared to those from the DTU-ESA Spherical Near-Field Facility with a good agreement in the validity region. Uncertainty investigations regarding...... cable flexing effects at 60 GHz have shown that these introduce an uncertainty of about 0.02 dB (1 sigma) around the main beam region indicating a very good performance of the PNF setup....

  15. Radiation damage measurements on CZT drift strip detectors

    DEFF Research Database (Denmark)

    Kuvvetli, Irfan; Budtz-Jørgensen, Carl; Korsbech, Uffe C C

    2003-01-01

    At DSRI, in collaboration with the cyclotron facility at Copenhagen University Hospital, we have performed a study of radiation effects exposing a 2.7 mm thick CZT drift strip detector to 30 MeV protons. The detector characteristics were evaluated after exposure to a number of fluences in the range...... from 2 x 10(8) to 60 x 10(8) p(+)/cm(2). Even for the highest fluences, which had a dramatic effect on the spectroscopic performance, we were able to recover the detectors after an appropriate annealing procedure. The radiation damage was studied as a function of depth inside the detector material...... with the proton dose. The radiation contribution to the electron trapping was found to obey the following relation: (mutau(e)(-1))(rad) = (2.5+/-0.2) x 10(-7) x Phi (V/cm)(2) with the proton fluence, Phi in p(+)/cm(2). The trapping depth dependence, however, did not agree well with the damage profile calculated...

  16. Ozonesonde measurements from the Atmospheric Radiation Measurement (ARM) site in Billings, Oklahoma

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    Ozonesonde instruments were prepared and released at the Atmospheric Radiation Measurement (ARM) site located near Billings, Oklahoma. Ozone sensors, associated radiosondes, balloons, and other parts and pieces required for the ozone observations were provided by WFF on a reimbursable arrangement with ANL. Observations were scheduled daily at 1,700 UTC beginning on September 22, 1995. Attempts to maintain this schedule were frustrated by a few simultaneous operations involving different electronic devices in use resulting in considerable rf noise. Since radiosondes are necessarily low-cost instruments their reception is particularly susceptible to noisy rf fields. Overall, however, 36 ozonesonde flights were made with the last observation occurring on November 1, 1995. Ozone data were processed on-site through the ground-station software and preliminary data delivered to Mike Splitt at the ARM site.

  17. External meeting: KATRIN - direct measurement of neutrino masses with sub-eV sensitivity

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY - ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 - Tél : 022 379 62 73 - Fax: 022 379 69 92 Wednesday 18 April 2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium KATRIN - direct measurement of neutrino masses with sub-eV sensitivity by Prof. Guido Drexlin, Karlsruhe Institute of Technology KIT The major scientific objective of the international Karlsruhe Tritum Neutrino (KATRIN) Experiment is the model independent measurement of the electron neutrino mass in tritium beta decay with a sensitivity of 200 meV. In the cosmological context, this allows an investigation of whether massive relic neutrinos left over from the Big Bang play a specific role as hot dark matter in the evolution of large scale structures of the universe. In particle physics KATRIN will allow for discrimination between different neutrino mass models (either of quasi-degenerate or hierarchical pattern).The key components of KATRIN comprise...

  18. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  19. Coherent transition radiation diagnostic for electron bunch shape measurement at FELIX

    Science.gov (United States)

    Ding, Meisong; Weits, H. H.; Oepts, D.

    1997-02-01

    An optical autocorrelation system using coherent transition radiation has been set up to determine the electron bunch shape at FELIX. A polarisation interferometer and a 10 × 10 mm 2 pyroelectric detector are used to allow operation over a wide range of wavelength (from 30 μm to 10 mm) without strong variation in efficiency. An evacuated 15 m long overmoded waveguide is used to transport the transition radiation to the experimental area. The intensity of the transition radiation was measured and compared with our calculation. The phase-retrieval technique applied to the measured spectrum provides details of the electron bunch. The bunch shapes have been studied at different buncher phase settings. Measurements of coherent transition radiation and coherent undulator radiation are compared.

  20. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  1. Detector Response and Beam Line Transmission Measurements with Far-Infrared Radiation

    CERN Document Server

    Grimm, O; Fröhlich, L

    2005-01-01

    Various activities at the TTF linear accelerator at DESY, Hamburg, that drives the VUV-FEL are geared towards measuring the longitudinal charge distribution of electron bunches with coherent far-infrared radiation. Examples are beam lines transporting synchrotron or transition radiation to interferometers mounted inside or outside the tunnel, and studies of single-shot grating spectrometers. All such approaches require a good understanding of the radiation generation and transport mechanism and of the detector characteristics to extract useful information on the charge distribution. Simulations and measurements of the expected transverse intensity distribution and polarization of synchrotron radiation emitted at the first bunch compressor of TTF have been performed. The transverse intensity scanning provided for the first time at DESY a visual image of the footprint of terahertz radiation. Detector response measurements have been performed at the FELIX facility, Netherlands, for wavelengths between 100-160 mi...

  2. UV radiation in global climate change. Measurements, modeling and effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Wei; Slusser, James R. (eds.) [Colorado State Univ., CO (United States). Natural Resource Ecology Lab.; Schmoldt, Daniel L. [Waterfront Centre, Washington, DC (United States). Cooperative State Research Education and Extension Service

    2010-07-01

    Numerous studies report that ultraviolet (UV) radiation is harmful to living organisms and detrimental to human health. Growing concerns regarding the increased levels of UV-B radiation that reach the earth's surface have led to the development of ground- and space-based measurement programs. Further study is needed on the measurement, modeling, and effects of UV radiation. The chapters of this book describe the research conducted across the globe over the past three decades in the areas of: (1) current and predicted levels of UV radiation and its associated impact on ecosystems and human health, as well as economic and social implications; (2) new developments in UV instrumentation, advances in calibration (ground- and satellite-based), measurement methods, modeling efforts, and their applications; and (3) the effects of global climate change on UV radiation. (orig.)

  3. Influence of Participating Media on the Radiation Thermometry for Surface Temperature Measurement

    Institute of Scientific and Technical Information of China (English)

    Yuying LIU; Xinxin ZHANG

    2005-01-01

    A temperature measurement model of radiation thermometry for the surface covered by participating media was developed. The model was based on the radiation heat transfer of participating media and principles of radiation pyrometers, and solved by integral formulation of discrete ordinate method on spectral waveband. The influence of water mist on the indicated temperature of Raytek MR1SB one/two color pyrometer was discussed. Mie theory was used to calculate the radiative properties of water mist. In order to verify the model, a laboratory temperature measurement experiment was executed. The result shows that temperature of radiation thermometry is sensitive to the spectral response wavelength of pyrometer, and the simulated temperature of pyrometer agrees well with the experimental measurements on a suitable wavelength. The simulated temperature was lower than the real temperature of surface for one-color pyrometer, and it could be higher or lower than the real one for two-color pyrometer with the influence of participating media.

  4. Monitoring T2 and ADC at 9.4 T following fractionated external beam radiation therapy in a mouse model

    Science.gov (United States)

    Larocque, Matthew P.; Syme, Alasdair; Yahya, Atiyah; Wachowicz, Keith; Allalunis-Turner, Joan; Fallone, B. Gino

    2010-03-01

    The purpose of this study is to investigate the response of transverse relaxation time (T2) and apparent diffusion coefficient (ADC) in human glioma tumor xenografts during and after fractionated radiotherapy. Tumor-bearing mice were divided into four treatment groups (n = 6 per group) that received a total dose of 800 cGy of 200 kVp x-rays, given over two or three fractions, with a fraction spacing of either 24 or 72 h. A fifth treatment group received 800 cGy in a single fraction, and a sixth group of mice served as an untreated control. All mice were scanned pretreatment, before each fraction and at multiple points after treatment using a 9.4 T magnetic resonance imaging (MRI) system. Quantitative T2 and ADC maps were produced. All treated groups showed an increase in mean tumor ADC, though the time for this response to reach a maximum and return toward baseline was delayed in the fractionated groups. The highest ADC was measured 7 days after the final fraction of treatment for all groups. There were no significant differences in the maximum measured change in ADC between any of the treated groups, with the average measured maximum value being 20.5% above baseline. After treatment, all groups showed an increase in mean tumor T2, with the average measured maximum T2 being 4.7% above baseline. This increase was followed by a transition to mean T2 values below baseline values, with the average measured tumor T2 being 92.4% of the pretreatment value. The transition between elevated and depressed T2 values was delayed in the cases of fractionated therapies and occurred between 3.6 and 7.3 days after the last fraction of treatment. These results further the understanding of the temporal evolution of T2 and ADC during fractionated radiotherapy and support their potential use as time-sensitive biomarkers for tumor response.

  5. Towards an Evaluation of Air Surveillance Track Clustering Algorithms via External Cluster Quality Measures

    Science.gov (United States)

    2013-01-01

    output. This function is referred to as PRM (for "Peak Rolling Mean") in the following table. By combining these track separation measures with the...9.39 5 1055 Mean-60k 60 km 403 10.28 5 858 Mean-70k 70 km 369 11.62 6 712 Mean-80k Simple Mean n/a 80 km 350 12.54 6 611 PRM :50-30k 30 km 427...7.49 4 1801 PRM :50-40k 40 km 375 6.79 4 2454 PRM :50-50k 50 km 405 7.06 4 2139 PRM :50-60k 60 km 412 7.46 4 1928 PRM :50-70k 70 km 427 7.76 4 1685

  6. Evaluation of solar radiation measurement systems: EPRI/NREL final test report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Stoffel, T; Riordan, C; Bigger, J

    1992-11-01

    Measured solar radiation resource data are needed by electric utilities to evaluate the potential of renewable energy options like photovoltaics in their service territory. In this final test report, we document a cooperative project of the Electric Power Research Institute (EPRI) and the National Renewable Energy Laboratory (NREL) to compare available measurement system options for performing solar radiation resource assessments. We present the detailed results of a 6-month field comparison of thermopile-based pyranometer and pyrheliometer solar irradiance measurement systems with two different implementations of the rotating shadowband radiometer (RSR) concept installed at NREL`s Solar Radiation Research Laboratory (SRRL) in Golden, Colorado.

  7. Macro-Bending Influence on Radiation Induced Attenuation Measurement in Optical Fibres

    CERN Document Server

    Guillermain, E; Ricci, D; Weinand, U

    2014-01-01

    Influence of the bending radius on the measurement of radiation induced attenuation in glass optical fibres is discussed in this paper. Radiation induced attenuation measured in two single-mode fibre types shows discrepancies when coiled around a low bending radius spool: the observed attenuation is lower than expected. A series of dedicated tests reveals that this invalid measurement is related to the displacement of the mode field towards the cladding when the fibre is bent with a low radius, and to the different radiation resistances of the core and cladding glasses. For irradiation tests of optical fibres, the spool radius should therefore be carefully chosen.

  8. BOBMEX-98 Pilot: Measurement and analysis of incoming shortwave radiation data

    Indian Academy of Sciences (India)

    K Gopala Reddy; P Sree Ram

    2000-06-01

    Empirical formulae for estimation of hourly incoming shortwave radiation over the Indian Ocean under different cloud amounts have been developed by using the pyranometer measurements of the incoming solar radiation and the cloud observations during BOBMEX Pilot (October - November 1998) cruise.

  9. Impact of the radiation trapping on lifetime measurement of Er{sup 3+} doped glasses

    Energy Technology Data Exchange (ETDEWEB)

    Stoita, A.; Vautey, T.; Jacquier, B. [Universite de Lyon, Lyon F-69000 (France); Universite Lyon 1, Villeurbanne F-69622 (France); CNRS, UMR5620, Laboratoire de Physico-Chimie des Materiaux Luminescents F-69622 Villeurbanne Cedex (France); Guy, S., E-mail: guy@pcml.univ-lyon1.f [Universite de Lyon, Lyon F-69000 (France); Universite Lyon 1, Villeurbanne F-69622 (France); CNRS, UMR5620, Laboratoire de Physico-Chimie des Materiaux Luminescents F-69622 Villeurbanne Cedex (France)

    2010-07-15

    We report on the interplay between experimental arrangement, resonant radiation trapping and decay measurements of infra-red emission of erbium doped glasses. The impact of the relative position between the exciting and detecting positions of the bulk samples is investigated. We show that the radiation trapping leads to long rise time dynamics evenly distributed outside the pulsed pumped region.

  10. Deriving aerosol properties from measurements of the Atmosphere-Surface Radiation Automatic Instrument (ASRAI)

    Science.gov (United States)

    Xu, Hua; Li, Donghui; Li, Zhengqiang; Zheng, Xiaobing; Li, Xin; Xie, Yisong; Liu, Enchao

    2015-10-01

    The Atmosphere-surface Radiation Automatic Instrument (ASRAI) is a newly developed hyper-spectral apparatus by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences (AIOFM, CAS), measuring total spectral irradiance, diffuse spectral irradiance of atmosphere and reflected radiance of the land surface for the purpose of in-situ calibration. The instrument applies VIS-SWIR spectrum (0.4~1.0 μm) with an averaged spectral resolution of 0.004 μm. The goal of this paper is to describe a method of deriving both aerosol optical depth (AOD) and aerosol modes from irradiance measurements under free cloudy conditions. The total columnar amounts of water vapor and oxygen are first inferred from solar transmitted irradiance at strong absorption wavelength. The AOD together with total columnar amounts of ozone and nitrogen dioxide are determined by a nonlinear least distance fitting method. Moreover, it is able to infer aerosol modes from the spectral dependency of AOD because different aerosol modes have their inherent spectral extinction characteristics. With assumption that the real aerosol is an idea of "external mixing" of four basic components, dust-like, water-soluble, oceanic and soot, the percentage of volume concentration of each component can be retrieved. A spectrum matching technology based on Euclidean-distance method is adopted to find the most approximate combination of components. The volume concentration ratios of four basic components are in accordance with our prior knowledge of regional aerosol climatology. Another advantage is that the retrievals would facilitate the TOA simulation when applying 6S model for satellite calibration.

  11. Solar radiation measurements from coordinated radiosonde flights during the 20th March 2015 solar eclipse

    Science.gov (United States)

    Harrison, R. Giles; Marlton, Graeme; Williams, Paul; Nicoll, Keri

    2016-04-01

    Solar radiation sensors can be carried on standard weather balloon packages and provide additional information about the atmosphere's vertical structure beyond the traditional thermodynamic measurements [1]. An interesting set of circumstances for such sensors occurs during a solar eclipse, which provides a rapidly changing solar radiation environment within the duration of a typical free balloon flight. Coordinating several launches of solar radiation measuring radiosondes brings a good likelihood of at least one being above any cloud during the maximum eclipse, allowing solar eclipse radiation measurements for comparison with theory. For the 20th March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44N, 0.94W), Lerwick (60.15N, 1.13W) and Reykjavik (64.13N, 21.90W), straddling the path of the eclipse. All three balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. These approaches, which are essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes. [1] K.A. Nicoll and R.G. Harrison, Balloon-borne disposable radiometer Rev Sci Instrum 83, 025111 (2012) doi: 10.1063/1.3685252

  12. Evaluation of Diversity Antenna Designs Using Ray Tracing, Measured Radiation Patterns, and MIMO Channel Measurements

    Directory of Open Access Journals (Sweden)

    Arindam Pal

    2007-01-01

    Full Text Available This paper presents an evaluation of the MIMO performance of three candidate antenna array designs, each embedded within a PDA footprint, using indoor wideband channel measurements at 5.2 GHz alongside channel simulations. A channel model which employs the plane-wave approximation was used to combine the embedded antenna radiation patterns of the candidate devices obtained from far-field pattern measurements and multipath component parameters from an indoor ray-tracer. The 4-element candidate arrays were each constructed using a different type of antenna element, and despite the diverse element directivities, pattern characteristics, and polarization purities, all three devices were constructed to fully exploit diversity in polarization, space, and angle. Thus, low correlation and high information theoretic capacity was observed in each case. A good match between the model and the measurements is also demonstrated, especially for 2×2 MIMO subsets of identically or orthogonally polarized linear slot antennas. The interdependencies between the channel XPD, directional spread and pathloss, and the respective impact on channel capacity are also discussed in this paper.

  13. Evaluation of Diversity Antenna Designs Using Ray Tracing, Measured Radiation Patterns, and MIMO Channel Measurements

    Directory of Open Access Journals (Sweden)

    Pal Arindam

    2007-01-01

    Full Text Available This paper presents an evaluation of the MIMO performance of three candidate antenna array designs, each embedded within a PDA footprint, using indoor wideband channel measurements at 5.2 GHz alongside channel simulations. A channel model which employs the plane-wave approximation was used to combine the embedded antenna radiation patterns of the candidate devices obtained from far-field pattern measurements and multipath component parameters from an indoor ray-tracer. The 4-element candidate arrays were each constructed using a different type of antenna element, and despite the diverse element directivities, pattern characteristics, and polarization purities, all three devices were constructed to fully exploit diversity in polarization, space, and angle. Thus, low correlation and high information theoretic capacity was observed in each case. A good match between the model and the measurements is also demonstrated, especially for MIMO subsets of identically or orthogonally polarized linear slot antennas. The interdependencies between the channel XPD, directional spread and pathloss, and the respective impact on channel capacity are also discussed in this paper.

  14. Radioactivity measurement of radioactive contaminated soil by using a fiber-optic radiation sensor

    Science.gov (United States)

    Joo, Hanyoung; Kim, Rinah; Moon, Joo Hyun

    2016-06-01

    A fiber-optic radiation sensor (FORS) was developed to measure the gamma radiation from radioactive contaminated soil. The FORS was fabricated using an inorganic scintillator (Lu,Y)2SiO5:Ce (LYSO:Ce), a mixture of epoxy resin and hardener, aluminum foil, and a plastic optical fiber. Before its real application, the FORS was tested to determine if it performed adequately. The test result showed that the measurements by the FORS adequately followed the theoretically estimated values. Then, the FORS was applied to measure the gamma radiation from radioactive contaminated soil. For comparison, a commercial radiation detector was also applied to measure the same soil samples. The measurement data were analyzed by using a statistical parameter, the critical level to determine if net radioactivity statistically different from background was present in the soil sample. The analysis showed that the soil sample had radioactivity distinguishable from background.

  15. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    a simulation of a radioactive plume passing over the monitors during a certain time was made using a specially designed source set up in the field that was able to vary the air kerma rate from low activity Cs-137 sources additional to the natural air kerma rate. It is demonstrated that a typical environmental...... radiation detector can distinguish an increase of the ambient air kerma rate of less than 3%....

  16. SU-E-T-447: Growth of Metal Whiskers Under External Beam Irradiation: Experimental Evidence and Implications in Medical Electronic Devices for Radiation Therapy Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Shvydka, D; Warrell, G; Parsai, E [University of Toledo Health Science Campus, Toledo, OH (United States); Karpov, V; Vasko, A [University of Toledo, Toledo, OH (United States)

    2015-06-15

    Purpose: Thin metallic protrusions, termed “whiskers,” have been identified as a cause of failure in devices ranging from satellites to pacemakers. For decades, lead was used in tin-based soldering alloys to suppress whisker formation. With the adoption of the Restriction of Hazardous Substances act and the expiration of its exemption on medical devices, including implanted medical devices (IMDs), electronic circuits are required to be lead-free as of July 2014. The effect of radiation on such soldering components remains unknown. Methods: We have irradiated a thin (150 nm) tin metal layer, deposited on a 3 mm thick glass substrate, with a 6 MeV medical linac (Varian TrueBeam) electron beam in five 2-hour long sessions. After receiving ∼10 kGy, whisker growth on the sample was assessed with scanning electron microscopy and compared to a reference sample not exposed to radiation. Results: After 10 hours of irradiation, the sample was found to develop intense whisker infestation, while the reference sample remained in its pristine as-deposited condition. Repeating the same irradiation schedule generated more and longer whiskers. The observed phenomenon can be explained through charge accumulation in the glass substrate, generating an electric field that promotes whisker growth. The observed substrate glass darkening under irradiation points towards development of color centers related to charge trapping. Experiments on the same type of samples with direct application of the external field in a capacitor-like setting also resulted in intense whisker growth. Conclusion: Extreme care should be taken in dealing with all electronic devices, especially IMDs, produced with lead-free solder and components, subject to radiation exposure. While in our experiments strong electric fields were intentionally generated to accelerate whisker growth over hours, in everyday use the circuit soldering may cause problems in a matter of days or months. Designated reliability testing

  17. Simultaneous high-speed internal and external flow measurements for a high-pressure diesel nozzle

    CERN Document Server

    Purwar, Harsh; Méès, Loïc; Rozé, Claude; Blaisot, Jean-Bernard; Michard, Marc; Maligne, David

    2016-01-01

    We present an extensive experimental study focused on understanding the impact of cavitation in a high-pressure diesel nozzle on the macroscopic properties of fuel spray. Several high-speed videos of the liquid flow through a transparent, asymmetric cylindrical nozzle with a single orifice (phi = 0.35 mm) are recorded along with the videos of the resulting spray in the near-nozzle region, issued with an injection pressure of 300 bar at a frame-rate of 75 kHz. The high-repetition images of the internal flow are then used to estimate the onset of cavitation inside the transparent nozzle and the probability of development of cavitation in different regions of the nozzle with an average estimate of the amount of cavitation with time. On the other hand, recorded spray images are used to study spray penetration, cone-angles and velocity from the start of fuel injection. A novel approach is proposed for the measurement of perturbations that occur in form of big liquid structures along the spray boundary.

  18. External measurements on BP Solar 7180 Saturn modules in Australia and Germany; Externe Messungen an BP Solar 7180 Saturn Modulen in Australien und Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Ransome, S.; Mason, N. [BP Solar, Sunbury on Thames (United Kingdom); Deponte, K. [BP Solar, Hamburg (Germany); Fernandez, J.; Russell, R. [BP Solar, Poligono Industrial, Zona Oeste, Madrid (Spain)

    2005-07-01

    The BP 7180 module produced by BP Solar was tested in Sydney, Australia, and Kassel, Germany in open fields in realistic operating conditions. Empirical adaptations were used for achieving optimal module performance in PTC conditions. The results were compared with flash test results and with rated capacities. The modules achieved efficiencies up to 86 percent, even with low radiation densities of 200 W/m{sup 2} and a remarkable good light yeald in weak light of less than 50 W/m{sup 2}. (orig.)

  19. Measurements of the spectrum and energy dependence of X-ray transition radiation

    Science.gov (United States)

    Cherry, M. L.

    1978-01-01

    The results of experiments designed to test the theory of X-ray transition radiation and to verify the predicted dependence of the characteristic features of the radiation on the radiator dimensions are presented. The X-ray frequency spectrum produced by 5- to 9-GeV electrons over the range 4 to 30 keV was measured with a calibrated single-crystal Bragg spectrometer, and at frequencies up to 100 keV with an NaI scintillator. The interference pattern in the spectrum and the hardening of the radiation with increasing foil thickness are clearly observed. The energy dependence of the total transition-radiation intensity was studied using a radiator with large dimensions designed to yield energy-dependent signals at very high particle energies, up to E/mc-squared approximately equal to 100,000. The results are in good agreement with the theoretical predictions.

  20. Advanced radiation measurement techniques in diagnostic radiology and molecular imaging.

    Science.gov (United States)

    Del Guerra, Alberto; Belcari, Nicola; Llacer, Gabriela Llosa; Marcatili, Sara; Moehrs, Sascha; Panetta, Daniele

    2008-01-01

    This paper reports some technological advances recently achieved in the fields of micro-CT and small animal PET instrumentation. It highlights a balance between image-quality improvement and dose reduction. Most of the recent accomplishments in these fields are due to the use of novel imaging sensors such as CMOS-based X-ray detectors and silicon photomultipliers (SiPM). Some of the research projects carried out at the University of Pisa for the development of such advanced radiation imaging technology are also described.

  1. Can we predict plan quality for external beam partial breast irradiation: results of a multicenter feasibility study (Trans Tasman Radiation Oncology Group Study 06.02).

    Science.gov (United States)

    Kron, Tomas; Willis, David; Link, Emma; Lehman, Margot; Campbell, Gillian; O'Brien, Peter; Chua, Boon

    2013-11-15

    Partial breast irradiation (PBI) after lumpectomy may be an option for selected patients with early breast cancer. A feasibility study of accelerated PBI delivered using external beam 3-dimensional conformal radiation therapy (RT) was undertaken at 8 Australasian centers. The present study evaluated the impact of patient, tumor, and RT technique-related factors on the quality of RT plans as determined by the dose-volume parameters of organs at risk. Forty-eight patients were enrolled in the study. All RT plans were centrally reviewed using predefined dosimetric criteria before commencement and after completion of protocol therapy. The RT plans of 47 patients met the dose-volume constraints, and all 47 patients received PBI to a prescribed dose of 38.5 Gy in 10 fractions. The RT plan quality was determined by volumes of the ipsilateral whole breast, lung, and heart that received 50% and 95%; 30%; and 5% of the prescribed dose, respectively. Patient, tumor, and RT technique-related factors were investigated for association with the parameters of RT plan quality. The ratio of the planning target volume to the ipsilateral whole-breast volume was significantly associated with the ipsilateral breast doses on multiple variable analyses. The distance of the postlumpectomy surgical cavity from the heart and lung were predictive for heart and lung doses, respectively. A distance between surgical cavity and heart of >4 cm typically resulted in planning target volume to ipsilateral whole-breast volume and the distance of surgical cavity from the heart were significant predictors of the quality of treatment plan for external beam PBI. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Can We Predict Plan Quality for External Beam Partial Breast Irradiation: Results of a Multicenter Feasibility Study (Trans Tasman Radiation Oncology Group Study 06.02)

    Energy Technology Data Exchange (ETDEWEB)

    Kron, Tomas, E-mail: Tomas.Kron@petermac.org [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia); School of Science, Engineering and Technology, Royal Melbourne Institute of Technology University, Melbourne, Victoria (Australia); Willis, David; Link, Emma [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Lehman, Margot [Princess Alexandra Hospital, Department of Radiation Oncology, Brisbane, Queensland (Australia); Campbell, Gillian [Auckland City Hospital, Department of Radiation Oncology, Auckland (New Zealand); O' Brien, Peter [Newcastle Calvary Mater Hospital, Department of Radiation Oncology, Newcastle, NSW (Australia); Chua, Boon [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia)

    2013-11-15

    Purpose: Partial breast irradiation (PBI) after lumpectomy may be an option for selected patients with early breast cancer. A feasibility study of accelerated PBI delivered using external beam 3-dimensional conformal radiation therapy (RT) was undertaken at 8 Australasian centers. The present study evaluated the impact of patient, tumor, and RT technique-related factors on the quality of RT plans as determined by the dose–volume parameters of organs at risk. Methods and Materials: Forty-eight patients were enrolled in the study. All RT plans were centrally reviewed using predefined dosimetric criteria before commencement and after completion of protocol therapy. The RT plans of 47 patients met the dose–volume constraints, and all 47 patients received PBI to a prescribed dose of 38.5 Gy in 10 fractions. The RT plan quality was determined by volumes of the ipsilateral whole breast, lung, and heart that received 50% and 95%; 30%; and 5% of the prescribed dose, respectively. Patient, tumor, and RT technique-related factors were investigated for association with the parameters of RT plan quality. Results: The ratio of the planning target volume to the ipsilateral whole-breast volume was significantly associated with the ipsilateral breast doses on multiple variable analyses. The distance of the postlumpectomy surgical cavity from the heart and lung were predictive for heart and lung doses, respectively. A distance between surgical cavity and heart of >4 cm typically resulted in <1% of the heart volume receiving 5 Gy or less. It was more difficult to meet the heart dose constraint for left-sided and medially located tumors. Conclusions: Partial breast irradiation using 3-dimensional conformal RT was feasible within the study constraints. The ratio of planning target volume to ipsilateral whole-breast volume and the distance of surgical cavity from the heart were significant predictors of the quality of treatment plan for external beam PBI.

  3. Spectral Signature of Column Solar Radiation Absorption During the Atmospheric Radiation Measurement Enhanced Shortwave Experiment (ARESE). Revision

    Energy Technology Data Exchange (ETDEWEB)

    O' Hirok, William; Gautier, Catherine; Ricchiazzi, Paul

    1999-11-01

    Spectral and broadband shortwave radiative flux data obtained from the Atmospheric Radiation Measurement Enhanced Shortwave Experiment (ARESE) are compared with 3-D radiative transfer computations for the cloud field of October 30, 1995. Because the absorption of broadband solar radiation in the cloudy atmosphere deduced from observations and modeled differ by 135 Wm{sup -2}, we performed a consistency analysis using spectral observations and the model to integrate for wavelengths between the spectral observations. To match spectral measurements, aerosols need a reduction in both single scattering albedo (from 0.938 to 0.82) and asymmetry factor (from 0.67 to 0.61), and cloud droplets require a three-fold increase in co-albedo. Even after modifying the model inputs and microphysics the difference in total broadband absorption is still of the order of 75Wm{sup -2}. Finally, an unexplained absorber centered around 1.06 {micro}m appears in the comparison that is much too large to be explained by dimers.

  4. External Tonehole Interactions in Woodwind Instruments

    CERN Document Server

    Lefebvre, Antoine; Kergomard, Jean

    2012-01-01

    The transfer matrix method is often used to calculate the input impedance of woodwind instruments but it ignores the possible influence of the radiated sound from toneholes on other open holes. In this paper, a method is proposed to account for external tonehole interactions. It is found that the external tonehole interactions increase the amount of radiated energy, reduce slightly the lower resonance frequencies, and modify significantly the response near and above the tonehole lattice cutoff frequency. The results of simulations with the Finite Element Method, as well as experimental measurements, are presented and compared to the calculation with the method presented in this paper, confirming that the external tonehole interactions play a significant role in woodwind instrument.

  5. Cosmic radiation dose measurements from the RaD-X flight campaign

    Science.gov (United States)

    Mertens, Christopher J.; Gronoff, Guillaume P.; Norman, Ryan B.; Hayes, Bryan M.; Lusby, Terry C.; Straume, Tore; Tobiska, W. Kent; Hands, Alex; Ryden, Keith; Benton, Eric; Wiley, Scott; Gersey, Brad; Wilkins, Richard; Xu, Xiaojing

    2016-10-01

    The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5°N, 104.2°W) on 25 September 2015. Over 18 h of flight data were obtained from each of the four different science instruments at altitudes above 20 km. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

  6. External validation of a measurement tool to assess systematic reviews (AMSTAR.

    Directory of Open Access Journals (Sweden)

    Beverley J Shea

    Full Text Available BACKGROUND: Thousands of systematic reviews have been conducted in all areas of health care. However, the methodological quality of these reviews is variable and should routinely be appraised. AMSTAR is a measurement tool to assess systematic reviews. METHODOLOGY: AMSTAR was used to appraise 42 reviews focusing on therapies to treat gastro-esophageal reflux disease, peptic ulcer disease, and other acid-related diseases. Two assessors applied the AMSTAR to each review. Two other assessors, plus a clinician and/or methodologist applied a global assessment to each review independently. CONCLUSIONS: The sample of 42 reviews covered a wide range of methodological quality. The overall scores on AMSTAR ranged from 0 to 10 (out of a maximum of 11 with a mean of 4.6 (95% CI: 3.7 to 5.6 and median 4.0 (range 2.0 to 6.0. The inter-observer agreement of the individual items ranged from moderate to almost perfect agreement. Nine items scored a kappa of >0.75 (95% CI: 0.55 to 0.96. The reliability of the total AMSTAR score was excellent: kappa 0.84 (95% CI: 0.67 to 1.00 and Pearson's R 0.96 (95% CI: 0.92 to 0.98. The overall scores for the global assessment ranged from 2 to 7 (out of a maximum score of 7 with a mean of 4.43 (95% CI: 3.6 to 5.3 and median 4.0 (range 2.25 to 5.75. The agreement was lower with a kappa of 0.63 (95% CI: 0.40 to 0.88. Construct validity was shown by AMSTAR convergence with the results of the global assessment: Pearson's R 0.72 (95% CI: 0.53 to 0.84. For the AMSTAR total score, the limits of agreement were -0.19+/-1.38. This translates to a minimum detectable difference between reviews of 0.64 'AMSTAR points'. Further validation of AMSTAR is needed to assess its validity, reliability and perceived utility by appraisers and end users of reviews across a broader range of systematic reviews.

  7. 47 CFR 2.1053 - Measurements required: Field strength of spurious radiation.

    Science.gov (United States)

    2010-10-01

    ... FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS Equipment Authorization...) Measurements shall be made to detect spurious emissions that may be radiated directly from the cabinet, control... spurious emission. For this test, single sideband, independent sideband, and controlled...

  8. [Evaluation of uncertainty in measurement of radiated disturbance and analysis of the result].

    Science.gov (United States)

    Wang, Weiming; Jiang, Sui

    2012-03-01

    This paper evaluates the uncertainty in the measurement of radiated disturbance by analyzing and calculating the components that influence the uncertainty. And the effectiveness of the uncertainty testing has been confirmed through the ability validation.

  9. Developments in radiation, stimulation and observation facilities in luminescence measurements

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Andersen, C.E.; Duller, G.A.T.;

    2003-01-01

    This paper summarises recent developments in the Riscircle divide TL/OSL reader. These new developments include an elevated temperature irradiation facility that has been expanded to measure variable temperature radioluminescence (RL) during beta irradiation. This RL facility allows the measurement...... facilities, and illustrates their applications with representative measurements. (C) 2003 Elsevier Science Ltd. All rights reserved....

  10. [Long-term oncologic outcomes of localized high-risk prostate cancer undergoing brachytherapy combined with external-beam radiation therapy and maximal androgen blockade].

    Science.gov (United States)

    Luo, Y; Li, M C; Qi, H Z; Zhao, J H; Han, Y L; Lin, Y H; Hou, Z; Jiang, Y G

    2017-07-11

    Objective: To investigate the oncologic outcome and PSA kinetics of localized high-risk prostate cancer (PCa) patients treated with combination strategy of radiation therapy (RT) and maximal androgen blockade (MAB). Methods: We retrospectively reviewed the clinical data of 320 localized PCa patients undergoing RT+ MAB from 2001 to 2015. And radiation treatment protocol consisted of permanent prostate brachytherapy (PPB) at 110 Gy and EBRT at 45 Gy/23 fractions. Results: The median follow-up time was 90 (range: 12-186) months. And 117 (36.6%) cases underwent MAB + external-beam radiotherapy (EBRT), and other 203 (63.4%) cases received MAB+ EBRT+ PPB. Multivariate Cox regression analyses showed that PSA kinetics were positive indicators of oncologic outcomes. Furthermore, PSA kinetics were aberrantly improved by supplemental PPB to MAB+ EBRT as following, PSA nadir (1.3±0.7)μg/L vs(0.11±0.06)μg/L, time of PSA decrease to nadir (7.5±1.8)months vs (3.2±2.1)months, PSA doubling time (15.6±4.2)months vs (22.6±6.1)months, PSA decreasing amplitude (84.6±6.2)%vs(95.8±3.4)%. Additionally, the median time of several important oncologic events in MAB+ EBRT+ PPB group were also prolonged than that in MAB+ EBRT group as following, overall survival (12.3 years vs 9.1 years, PPPB is extremely effective combination strategy for localized high-risk PCa patients, and PPB plays the important synergistic role in improving PSA kinetics, which are independent predictor for oncologic outcomes.

  11. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  12. Do high radiation doses in locally advanced prostate cancer patients treated with 103Pd implant plus external beam irradiation cause increased urinary, rectal, and sexual morbidity?

    Science.gov (United States)

    Stone, Nelson N; Cesaretti, Jamie A; Rosenstein, Barry; Stock, Richard G

    2010-01-01

    To investigate the morbidity of higher radiation doses in prostate cancer patients. Five hundred eighty-five men treated with seed implantation and external beam irradiation were followed a median of 5 years (range, 2-11). Hormonal therapy (HT) of 9 months duration was used in 504 (86.2%) patients. The biologic effective dose (BED) was calculated using an alpha/beta of 2. Urinary incontinence (UI) and symptoms (IPSS) were prospectively collected. Rectal morbidity was scored according to the Radiation Therapy Oncology Group (RTOG) scale. Two BED dose groups of 220 Gy (n=136) were used. Comparisons of means were made by Student's t test, and the associations were tested by chi-square analysis (Pearson). Urinary retention developed in 36 (6.2%) and was not associated with BED or IPSS. Retention occurred more often with prostate volume >50 cc (17%, p=0.001). The median change in urinary symptoms (IPSS) was 1. Sixty-one percent with high BED were more likely to have increased postimplant symptoms compared with 39% with lower BED (p=0.025; odds ratio [OR], 1.107; 95% confidence interval [CI], 1.10-1.21). UI occurred in 25 patients (4.3%) and was only associated with a postimplant transurethral resection of the prostate (TURP) (n=25), 16% vs. 2.3% for no TURP (p=0.001; OR, 8; 95% CI, 2.4-27). Of the 373 patients initially potent, 204 (54.7%) maintained potency. Impotence was only associated with age at implant (p=0.001) and HT (p=0.004). Sixty-two (10.6%) patients had Grade 1-2 and 4 patients had Grade 3-4 (0.7%, 2 ulcers and 2 fistulas) rectal complications. Three of the Grade 3/4 complications occurred with a dose 220 Gy does not seem to increase morbidity. (c) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Skin toxicity from external beam radiation therapy in breast cancer patients: protective effects of Resveratrol, Lycopene, Vitamin C and anthocianin (Ixor®

    Directory of Open Access Journals (Sweden)

    Franco Rossella

    2012-01-01

    Full Text Available Abstract Introduction This is an observational study and the aim is to evaluate the effect of dietary supplements based on Resveratrol, Lycopene, Vitamin C and Anthocyanins (Ixor® in reducing skin toxicity due to external beam radiotherapy in patients affected by breast cancer. Materials and methods 71 patients were enrolled and they were divided in two different groups: a control group (CG of 41 patients treated with prophylactic topical therapy based on hyaluronic acid and topical steroid therapy in case of occurrence of radiodermatitis, and a Ixor-Group (IG of 30 patients treated also with an oral therapy based on Resveratrol, Lycopene, Vitamin C and Anthocyanin (Ixor® at a dose of 2 tablets/day, starting from 10 days before the radiation treatment until 10 days after the end of treatment. Skin toxicity has been related to PTV, to breast volume that received a radiation dose equal or lower than 107%, included between 107% and 110%, or greater than 110% of the prescribed dose. Moreover it's been studied the relationship between skin toxicity and the chemotherapy schedule used before treatment. We calculated in both groups the percentage of patients who had a skin toxicity of grade 2 or 3 (according to RTOG scale. Absolute risk reduction (ARR, relative risk (RR and odds ratio (OR have been calculated for each relationship. Results Control Group (CG patients with a PTV > 500 ml presented skin toxicity G2 + G3 in 30% of cases, versus 25% of Ixor-Group (IG [OR 0.77]. In patients with a PTV Conclusions The protective effect of Resveratrol, Lycopene, Vitamin C and Anthocyanin (Ixor® is more detected in patients with PTV

  14. Dynamics of patient reported quality of life and symptoms in the acute phase of online adaptive external beam radiation therapy for locally advanced cervical cancer.

    Science.gov (United States)

    Heijkoop, S T; Nout, R A; Quint, S; Mens, J W M; Heijmen, B J M; Hoogeman, M S

    2017-08-19

    For locally advanced cervical cancer patients, treated with External Beam Radiotherapy (EBRT), Quality of Life (QoL) questionnaires arefrequently used to evaluate treatment-related symptoms and functioning scales. Currently, it is unknown how those evolve during the radiation treatment course. In this prospective study we report on weekly-captured patient-reported QoL and symptoms during image-guided adaptive radiotherapy (IGART) of cervical cancer patients. Between January 2012 and September 2016, all locally advanced cervical cancer patients treated with IGART and brachytherapy with or without chemotherapy or hyperthermia, were eligible. QoL was assessed at baseline; weekly during the first five weeks of treatment; 1week, 1 and 3months after treatment, using the EORTC QLQ-C30 and the QLQ-CX24 questionnaires. Comparisons were made with an age-matched norm population. Among the 138 (70%) responders, most symptoms showed a moderate-to-large increase, reaching a maximum at the end of treatment, or first week after treatment with return to baseline value at 3months after treatment. While most symptoms gradually increased during the first five weeks, diarrhea and bowel cramps already markedly increased within the first three weeks to reach a plateau at the 5th week of treatment. Global health and functioning were temporarily decreased and returned to a plateau at baseline level 3months after treatment, except for cognitive functioning. A profound impact on QoL was observed during the radiation treatment course, temporarily affecting functioning. The maximum impaired was reached at the end of EBRT. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Development of Precision Information Measuring System for Ultraviolet Radiation

    Directory of Open Access Journals (Sweden)

    ROSHCHUPKIN, O.

    2014-08-01

    Full Text Available Results of studying the neural network method are presented to reduce the amount of calibration points for the multisensor (MS, in particular for the photodiode. This allows transmitting to the MS individual conversion function and provides the high accuracy of measurement. The structure of synthesized information-measuring system and its measuring channel has created for implementing of the proposed approach. A structural scheme is proposed as well for values transmitting the etalon measures to measuring systems. Its used to determine the errors of photodiodes, as those which are produced for customers. This assures the interchangeability of sensors when using the individual conversion function.

  16. A unified approach to deconvolution radiation spectra measured by radiochromic films

    Directory of Open Access Journals (Sweden)

    Stančić Velimir A.

    2002-01-01

    Full Text Available A method for the evaluation of energy distribution of a radiation source on the basis of measured space distribution of deposited energy is proposed. The measured data were obtained by using radiochromic films. Mathematical modeling is defined as a Fredholm integral equation inversion problem. Negative solutions were treated as an additional condition expressed through undefined energy group boundaries, caused by virtue of the physical phenomenon of statistical uncertainty. Examples are given of the electron source and neutron radiation field.

  17. Survey of radiofrequency radiation levels around GSM base stations and evaluation of measurement uncertainty

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2011-01-01

    Full Text Available This paper is a summary of broadband measurement values of radiofrequency radiation around GSM base stations in the vicinity of residential areas in Belgrade and 12 other cities in Serbia. It will be useful for determining non-ionizing radiation exposure levels of the general public in the future. The purpose of this paper is also an appropriate representation of basic information on the evaluation of measurement uncertainty.

  18. Nuclear Targets for a Precision Measurement of the Neutral Pion Radiative Width

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Philippe; Clinton, Eric; McWilliams, R.; Lawrence, Dave; Miskimen, Rory; Ahmidouch, Abdellah; Ambrozewicz, Pawel; Asaturyan, Arshak; Baker, O.; Benton, LaRay; Bernstein, Aron; Cole, Philip; Collins, Patrick; Dale, Daniel; Danagoulian, Samuel; Davidenko, G.; Demirchyan, Raphael; Deur, Alexandre; DOLGOLENKO, A.; Dzyubenko, Georgiy; Evdokimov, Anatoly; Feng, JIng; Gabrielyan, Marianna; Gan, Liping; Gasparian, Ashot; Glamazdin, Oleksandr; Goryachev, Vladimir; Gyurjyan, Vardan; Hardy, K.; Ito, Mark; Khandaker, Mahbubul; Kingsberry, Paul; Kolarkar, Ameya; Konchatnyi, Mykhailo; Korchin, O.; Korsch, Wolfgang; Kowalski, Stanley; Kubantsev, Mikhail; Kubarovsky, Valery; LARIN, Ilya; MATVEEV, V.; McNulty, Dustin; Milbrath, Brian; Minehart, Ralph; Mochalov, Vasiliy; Mtingwa, Sekazi; Nakagawa, Itaru; Overby, Steven; Pasyuk, Evgueni; Payen, Marvin; Pedroni, Ronald; Prok, Yelena; Ritchie, Barry; Salgado, Carlos; Sitnikov, Anatoly; Sober, Daniel; Stephens, W.; Teymurazyan, Aram; Underwood, Jarreas; VASILIEV, A.; VEREBRYUSOV, V.; Vishnyakov, Vladimir; Wood, Michael

    2009-12-01

    A technique is presented for precision measurements of the area densities, density * T, of approximately 5% radiation length carbon and 208Pb targets used in an experiment at Jefferson Laboratory to measure the neutral pion radiative width. The precision obtained in the area density for the carbon target is +/- 0.050%, and that obtained for the lead target through an x-ray attenuation technique is +/- 0.43%.

  19. Instrument for thermal radiation flux measurement in high temperature gas flow (Cuernavaca instrument)

    Energy Technology Data Exchange (ETDEWEB)

    Afgan, N.H. [Universidade Tecnica, Lisbon (Portugal); Leontiev, A.I. [Moscow State Technical University (Russian Federation)

    1995-05-01

    A new instrument for hemispherical radiation heat flux measurement is proposed. It is based on the theory of blow of the boundary layer, taking into account that at the critical mass flow rate through the porous surface the thermal boundary layer is blown off and only radiation flux from high temperature gases reaches the porous surface. With the measurement of blow of gas flow and the temperature of the porous material, the respective heat flux is obtained. (author)

  20. Measurement of the Pulse Radiation of an IRA in Time Domain

    Science.gov (United States)

    Stadtler, Thiemo; Ter Haseborg, Jan Luiken; Sabath, Frank

    For radiation of UWB pulses special Impulse Radiating Antennas (IRA) have been designed and are continuously improved. The measurement of its near field can help optimizing this antenna type. This paper presents a time domain scanner which is able to determine the transient near field. The so called double probe near field scanner can be employed to measure the two dimensional field distribution in time domain.

  1. An analysis of the Wheeler method for measuring the radiating efficiency of antennas

    Science.gov (United States)

    Smith, G. S.

    1977-01-01

    A model problem is formulated to evaluate the limitations imposed by the assumptions in the Wheeler or cap method for measuring the radiating efficiency of antennas. The antenna in the model is a circular loop and the radiation shield is a spherical metal shell. Calculated values of the actual efficiency of the antenna and the efficiency that would be measured using the Wheeler method are compared to determine the accuracy of the method and set guidelines for its application.

  2. Scientific system for high-resolution measurement of the circumsolar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schrott, Simeon, E-mail: thomas.schmidt@ise.fraunhofer.de; Schmidt, Thomas, E-mail: thomas.schmidt@ise.fraunhofer.de; Hornung, Thorsten, E-mail: thomas.schmidt@ise.fraunhofer.de; Nitz, Peter, E-mail: thomas.schmidt@ise.fraunhofer.de [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg (Germany)

    2014-09-26

    We developed a camera based system for measurements of the circumsolar radiation with a high angular resolution of 0.1 mrad. Subsequent measurements may be taken at intervals as short as 15 s. In this publication we describe the optical system in detail and discuss some aspects of the measurement method. First results from two days of measurement at Freiburg i. Br., Germany, are presented and compared to data from literature. The good results encourage us to perform longer measurement campaigns in future to better understand the influence of circumsolar radiation on the power yield of concentrating photovoltaic systems.

  3. Note: Measurement system for the radiative forcing of greenhouse gases in a laboratory scale.

    Science.gov (United States)

    Kawamura, Yoshiyuki

    2016-01-01

    The radiative forcing of the greenhouse gases has been studied being based on computational simulations or the observation of the real atmosphere meteorologically. In order to know the greenhouse effect more deeply and to study it from various viewpoints, the study on it in a laboratory scale is important. We have developed a direct measurement system for the infrared back radiation from the carbon dioxide (CO2) gas. The system configuration is similar with that of the practical earth-atmosphere-space system. Using this system, the back radiation from the CO2 gas was directly measured in a laboratory scale, which roughly coincides with meteorologically predicted value.

  4. Note: Measurement system for the radiative forcing of greenhouse gases in a laboratory scale

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Yoshiyuki [Department of Intelligent Mechanical Engineering, Fukuoka Institute of Technology, 3-30-1 Wajirohigashi, Higashiku, Fukuoka 811-0295 (Japan)

    2016-01-15

    The radiative forcing of the greenhouse gases has been studied being based on computational simulations or the observation of the real atmosphere meteorologically. In order to know the greenhouse effect more deeply and to study it from various viewpoints, the study on it in a laboratory scale is important. We have developed a direct measurement system for the infrared back radiation from the carbon dioxide (CO{sub 2}) gas. The system configuration is similar with that of the practical earth-atmosphere-space system. Using this system, the back radiation from the CO{sub 2} gas was directly measured in a laboratory scale, which roughly coincides with meteorologically predicted value.

  5. Radiation Measurements Performed with Active Detectors Relevant for Human Space Exploration.

    Science.gov (United States)

    Narici, Livio; Berger, Thomas; Matthiä, Daniel; Reitz, Günther

    2015-01-01

    A reliable radiation risk assessment in space is a mandatory step for the development of countermeasures and long-duration mission planning in human spaceflight. Research in radiobiology provides information about possible risks linked to radiation. In addition, for a meaningful risk evaluation, the radiation exposure has to be assessed to a sufficient level of accuracy. Consequently, both the radiation models predicting the risks and the measurements used to validate such models must have an equivalent precision. Corresponding measurements can be performed both with passive and active devices. The former is easier to handle, cheaper, lighter, and smaller but they measure neither the time dependence of the radiation environment nor some of the details useful for a comprehensive radiation risk assessment. Active detectors provide most of these details and have been extensively used in the International Space Station. To easily access such an amount of data, a single point access is becoming essential. This review presents an ongoing work on the development of a tool that allows obtaining information about all relevant measurements performed with active detectors providing reliable inputs for radiation model validation.

  6. Radiation measurements performed with active detectors relevant for human space exploration

    Directory of Open Access Journals (Sweden)

    Livio eNarici

    2015-12-01

    Full Text Available A reliable radiation risk assessment in space is a mandatory step for the development of countermeasures and long duration mission planning in human spaceflight.Research in radiobiology provides information about possible risks linked to radiation. In addition, for a meaningful risk evaluation, the radiation exposure has to be assessed to a sufficient level of accuracy. Consequently, both the radiation models predicting the risks and the measurements used to validate such models must have an equivalent precision. Corresponding measurements can be performed both with passive and active devices. The former are easier to handle, cheaper, lighter and smaller but they measure neither the time dependence of the radiation environment nor some of the details useful for a comprehensive radiation risk assessment. Active detectors provide most of these details and have been extensively used in the International Space Station (ISS.To easily access such an amount of data, a single point access is becoming essential. This review presents an ongoing work on the development of a tool which allows obtaining information about all relevant measurements performed with active detectors providing reliable inputs for radiation model validation.

  7. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Science.gov (United States)

    Lucarelli, F.; Calzolai, G.; Chiari, M.; Giannoni, M.; Mochi, D.; Nava, S.; Carraresi, L.

    2014-01-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN in Florence, an external beam facility is fully dedicated to measurements of elemental composition of atmospheric aerosol. The experimental set-up hitherto used for this kind of applications has been upgraded with the replacement of a traditional Si(Li) detector for the detection of medium-high Z elements with a silicon drift detector (SDD) with a big active area (80 mm2) and 450 μm thickness, with the aim of obtaining better minimum detection limits (MDL) and reduce measuring times. The Upilex extraction window has been replaced by a more resistant one (Si3N4). A comparison between the old Si(Li) and the new SDD for aerosol samples collected on different substrata like Teflon, Kapton and Nuclepore evidenced the better performances of the SDD. It allows obtaining better results (higher counting statistics, lower MDLs) even in shorter measuring times, thus allowing very fast analysis of both daily and hourly samples.

  8. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F., E-mail: lucarelli@fi.infn.it; Calzolai, G.; Chiari, M.; Giannoni, M.; Mochi, D.; Nava, S.; Carraresi, L.

    2014-01-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN in Florence, an external beam facility is fully dedicated to measurements of elemental composition of atmospheric aerosol. The experimental set-up hitherto used for this kind of applications has been upgraded with the replacement of a traditional Si(Li) detector for the detection of medium–high Z elements with a silicon drift detector (SDD) with a big active area (80 mm{sup 2}) and 450 μm thickness, with the aim of obtaining better minimum detection limits (MDL) and reduce measuring times. The Upilex extraction window has been replaced by a more resistant one (Si{sub 3}N{sub 4}). A comparison between the old Si(Li) and the new SDD for aerosol samples collected on different substrata like Teflon, Kapton and Nuclepore evidenced the better performances of the SDD. It allows obtaining better results (higher counting statistics, lower MDLs) even in shorter measuring times, thus allowing very fast analysis of both daily and hourly samples.

  9. An Algorithm to Calculate Phase-Center Offset of Aperture Antennas when Measuring 2-Dimensional Radiation Patterns

    Science.gov (United States)

    2015-01-01

    An Algorithm to Calculate Phase-Center Offset of Aperture Antennas when Measuring 2-Dimensional Radiation Patterns by Patrick Debroux...Offset of Aperture Antennas when Measuring 2-Dimensional Radiation Patterns Patrick Debroux and Berenice Verdin Survivability/Lethality Analysis... Antennas when Measuring 2-Dimensional Radiation Patterns 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S

  10. Measurements of radiation effects on a 4 Mb PSRAM memory

    Science.gov (United States)

    Gonçalez, Odair Lelis; Pereira Junior, Evaldo Carlos Fonseca; Vaz, Rafael Galhardo; Pereira, Marlon Antonio; Wirth, Gilson Inácio; Both, Thiago Hanna

    2014-11-01

    The results of a static test of tota