WorldWideScience

Sample records for external beam pixe

  1. External-beam PIXE analysis of small sculptures

    International Nuclear Information System (INIS)

    Gyodi, I.; Demeter, I.; Hollos-Nagy, K.; Kovacs, I.; Szokefalvi-Nagy, Z.

    1999-01-01

    Non-destructive analysis of precious art objects is an important tool to solve provenance problems or to facilitate restoration. External beam PIXE analysis is one of the most powerful and popular methods used in this respect. The paper summarises the external beam PIXE set-up at the Accelerator Laboratory in Budapest, and two selected applications are described. Different parts of a small Cambodian metal sculpture probably made in the 11th century were analysed. It was observed that the sculpture was composed of an iron core and an outer bronze shell. This sculptural technique was well known in the Middle-East but no indication has been found about its use in the Far-East, yet. Before its restoration paint traces on a wooden relief of St. Jerome made by an unknown artist in about 1600 were analysed. Different white and red paints were distinguished at selected points and the presence of titanium on a certain part of the relief was attributed to a repainting in modern times

  2. Elemental analysis with external-beam PIXE

    Science.gov (United States)

    Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.

    1992-05-01

    A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.

  3. Possibilities and conditions of applying PIXE analysis with external proton beam

    International Nuclear Information System (INIS)

    Potocek, V.

    1989-01-01

    The technical and methodological prerequisites are summed up for the use of the PIXE method with an external proton beam. The method is suitable for the preliminary analysis of unknown samples prior to the choice of the best suited analytical method, for the nondestructive analysis of rare samples such as unique works of art, of small amounts of materials which are difficult to access, etc., as well as for calibration and comparing analyses. As for the operators the application of the PIXE method with external proton beam assumes the availability of accelerator operating time, minimization of the length of exposure of the targets, optimization of parameters of the exciting beam and automation of the whole process. Attention is also devoted to technical provisions and organization of laboratory work. The design is described of an analytical unit using the PIXE method with external proton beam, and it is stated that the Van de Graaff accelerator at the Institute of Nuclear Physics in Rez near Prague could be used for the purpose. (Z.M.). 6 refs

  4. External beam PIXE analysis of painting

    International Nuclear Information System (INIS)

    Pascholati, Paulo R.; Rizzutto, Marcia A.; Barbosa, Marcel D.L.; Albuquerque, Cindy

    2005-01-01

    The preservation and conservation of mankind cultural heritage has become an important issue worldwide. Non-destructive analytical techniques are suitable, for example, to analyze precious and unique objects of art and archaeology. Among those techniques Particle Induced X-Ray Emission (PIXE) has good advantage to identify elemental composition present in these kinds of objects. The Laboratorio de Analise de Materiais por Feixes Ionicos-LAMFI of the Institute of Physics of the University of Sao Paulo has been installed an external beam facility for PIXE analysis. This new setup is being used for the analysis of archaeological pottery artifacts, paintings and biological tissues (teeth and bones), which are not compatible with the high vacuum of the regular PIXE target chamber. In addition most art and archaeological objects are too large for the evacuated analysis chamber. Applications of this facility will be presented in the analysis of one painting of the beginning of the last century. The chemical elements identified in the painting were Ca, Ti, Cr, Cu, Fe, Zn, Pb and Ba. The PIXE measurements were done non-destructively and no visible damage was observed on the irradiated object. (author)

  5. External beam pixe programs at the University of California, Davis

    International Nuclear Information System (INIS)

    Eldred, R.A.

    1983-01-01

    A PIXE system in which large or delicate samples are excited by a low-current external proton beam is described. This system has been used to analyze historical printed books and manuscripts, as well as a large variety of archeological artifacts. The steps used to protect the sample from unnecessary beam current are examined. A recent thorough study of the first volume of the Gutenberg 42-line Bible is described in some detail

  6. Trace element fingerprinting of jewellery rubies by external beam PIXE

    International Nuclear Information System (INIS)

    Calligaro, T.; Poirot, J.-P.; Querre, G.

    1999-01-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations

  7. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: calli@culture.nl; Poirot, J.-P.; Querre, G

    1999-04-02

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations.

  8. A new mapping acquisition and processing system for simultaneous PIXE-RBS analysis with external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Beck, L.; Walter, Ph.; Moignard, B.; Guillou, T.

    2010-01-01

    The combination of ion beam analysis techniques is particularly fruitful for the study of cultural heritage objects. For several years, the AGLAE facility of the Louvre laboratory has been implementing these techniques with an external beam. The recent set-up permits to carry out PIXE, PIGE and RBS simultaneously on the same analyzed spot with a particle beam of approximately 20 μm diameter. A new mapping system has been developed in order to provide elemental concentration maps from the PIXE and RBS spectra. This system combines the Genie2000 spectroscopy software with a homemade software that creates maps by handling acquisition with the object position. Each pixel of each PIXE and RBS maps contains the spectrum normalised by the dose. After analysing each pixel of the PIXE maps (low and high energy X-ray spectra) with the Gupixwin peak-fitting software, quantitative elemental concentrations are obtained for the major and trace elements. This paper presents the quantitative elemental maps extracted from the PIXE spectra and the development of RBS data processing for light element distribution and thin layer characterization. Examples on rock painting and lustrous ceramics will be presented.

  9. PIXE/PIGE characterisation of emeralds using an external micro-beam

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.; Poirot, J.-P.; Querre, G.; Salomon, J.; Zwaan, J.C.

    2000-01-01

    A large collection of emeralds of various occurrences has been analysed by PIXE/PIGE in view to establish a compositional database. Major elements (Be, Si, Al) and trace elements (Li, F, Na, Mg, Ca, Rb, Cs and transition metals) are determined using an external 3 MeV proton micro-beam. Elemental micro-mapping permits to select the useful provenance tracers. This database was applied to infer the origin of several ancient emeralds set on historical jewels

  10. Elemental analysis of artefacts - establishing external beam PIXE

    International Nuclear Information System (INIS)

    Alves, A.; Johnston, P.; Short, R.; Bubb, I.

    1999-01-01

    The development of an external PIXE facility on the 1 MV Tandetron accelerator at RMIT has led to a wide range of research possibilities. A proton beam, generated inside a vacuum is brought into air via an Au coated Kapton foil exit window (thickness 8μm, diameter 0.35mm). Monitoring of the beam intensity is achieved by detecting backscattered protons from the inside Au coating on the window. Artefacts, which may be too large to be placed inside the vacuum, are positioned in the beamline opposite the exit window. An optical system consisting of a CCD camera, alignment laser and two mirrors allows viewing of a region of the target 10mm x 10mm. This technique provides quantitative analysis of elements in the pigments used in paintings and on ceramics, which is a valuable tool in art conservation and authentication. Application of the technique to a ceramic sample from the historic house 'Viewbank' is described

  11. Elemental analysis of ancient Chinese bronze artifacts with external-beam PIXE

    International Nuclear Information System (INIS)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Shen, C.T.; Huang, Y.M.; Wu, S.C.; Hsieh, C.H.

    1992-01-01

    External-beam PIXE has been applied for the determination of the elemental composition of ancient Chinese bronze artifacts. Characteristic x-ray spectra from the samples bombarded with protons of 3 MeV have been measured with a HPGe detector. At each sample three spots were irradiated per run. Results of measurements on three fragments of bronze drinking vessels and helmet of Chinese ancient Chou and Shang dynasties (17th-8th century B.C.) are presented. To check the analytical method, we have also made measurements on the elemental composition of some modern coins. The results are discussed. (author)

  12. Elemental analysis of ancient Chinese bronze artifacts with external-beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Shen, C.T.; Huang, Y.M.; Wu, S.C.; Hsieh, C.H. [Academia Sinica, Taipei, TW (China). Inst. of Physics

    1992-12-31

    External-beam PIXE has been applied for the determination of the elemental composition of ancient Chinese bronze artifacts. Characteristic x-ray spectra from the samples bombarded with protons of 3 MeV have been measured with a HPGe detector. At each sample three spots were irradiated per run. Results of measurements on three fragments of bronze drinking vessels and helmet of Chinese ancient Chou and Shang dynasties (17th-8th century B.C.) are presented. To check the analytical method, we have also made measurements on the elemental composition of some modern coins. The results are discussed. (author).

  13. An Apparatus For Student Projects Using External-Beam PIXE And PIGE

    International Nuclear Information System (INIS)

    Correll, Francis D.; Edsall, Douglas W.; DePooter, Katherine A.; Maskell, Nicholas D.; Vanhoy, Jeffrey R.

    2011-01-01

    We recently installed a simple endstation at the Naval Academy Tandem Accelerator Laboratory to support student projects using external-beam PIXE and PIGE. It consists of a short, graphite-lined beamline extension with a thin window, an interlocked box that surrounds the target, detectors for x- and gamma rays, provision for flooding the target with helium gas, easily changed x-ray absorbers, and a compact video camera for monitoring the position of the beam spot. We used this system to measure the elemental composition of colonial-era architectural materials, principally bricks and mortar, from James Madison's Montpelier, the reconstructed Virginia estate of the fourth President of the United States. We describe the design and construction of the system, relate some of our experiences using it, and present some preliminary data from our investigations.

  14. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    Energy Technology Data Exchange (ETDEWEB)

    Constantinescu, B.; Cristea-Stan, D. [National Institute for Nuclear Physics and Engineering Horia Hulubei, Bucharest-Magurele (Romania); Kovács, I.; Szõkefalvi-Nagy, Z. [Wigner Research Centre for Phyics, Institute for Particle and Nuclear Physics, Budapest (Hungary)

    2013-07-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  15. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    International Nuclear Information System (INIS)

    Constantinescu, B.; Cristea-Stan, D.; Kovács, I.; Szõkefalvi-Nagy, Z.

    2013-01-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  16. Analyses of inks and papers in historical documents through external beam PIXE techniques

    International Nuclear Information System (INIS)

    Cahill, T.A.; Kusko, B.; California Univ., Davis; Schwab, R.N.

    1981-01-01

    PIXE analyses of documents can be carried out to high senstitivty in an external beam configuration designed to protect historical materials from damage. Test runs have shown that a properbly designed system with high solid angle can operate at less than 1% of the flux necessary to cause any discoloration whatsoever on papers of the 17th and 18th centuries. The composition of these papers is suprisingly complex, yet retains distinct association with the historical period, paper source, and even the individual sheets of paper that are folded and cut to make groups of pages. Early studies are planned on historical forgeries. (orig.)

  17. Trace elements in human, cattle and swine teeth, measured by external beam PIXE-PIGE setup

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Rizzutto, M.A.; Added, N.; Liguori Neto, R.; Acquadro, J.C.; Vilela, M.; Oliveira, T.R.C.F.; Markarian, R.A.; Mori, M.

    2001-01-01

    The use of animal teeth to replace human teeth in dentistry school classes and to test chemicals and fillings, motivated for a better characterization of the elementary composition of their enamel, since some of the chemical properties, adhesion and chemical compatibility may depend on these parameters. Cattle, swine and human teeth were collected by dentists of the University of Sao Paulo. These teeth came primarily from Sao Paulo region and were analyzed for trace elements at the Open Nuclear Physics Laboratory, using a high energy external proton beam, PIXE-PIGE setup

  18. Study on the proton-induced X-ray emission(PIXE) using external proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, M. Y.; Yoon, J. C.; Park, K. J. [Seoul Natioanl University, Seoul (Korea, Republic of)

    2008-04-15

    We intend to develop a system that can extract a proton beam into air for a qualitative, and quantitative PIXE analysis up to ppm(percent per million) composition. When such an R and D is accomplished, first it is possible to get equipped with a system for PIXE and PIGmE, second, it is possible to contribute to an academic progress by the study for physical properties of matter through an nuclear science methods when the comparison between the measurement and the calculated quantities, and third, it is possible to contribute to a multi-disciplinary researches by the measurements of the samples for which it is hard to get the SRM for the samples. We intend to develop methods to measure the beam current for an air-borne proton beam, and to minimize the energy and current loss of the beam. We intend to acquire a set of PIXE data for rare-earth metals and transient metals, to form a basic database for the analysis for various samples for which it is hard to get the SRM. Developed PIXE beamline can extract the beam diameter up to 5mm, and beam intensity in the range 0.5nA to 10nA variable. sustaining the vacuum better than 10{sup -6} mtorr. Necessary detection system and methodology are complete. As the application of the present research achievements, we studied the analysis of aerosol composition, the appraisal of the cultural heritages, and a feasibility study for a proton beam writing. It is expected to become possible to analyse the compositions of the gems, the elemental compositions of the food, the discrimination of the traditional ink and the modern ink on the documents, the evaluation of the documents by the analysis of the elemental composition of the stamps, The analysis of the paper with respect to the date and the quality, the analysis of the color, and the core bored samples

  19. PIXE analysis using external proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Potocek, V; Potockova, J; Dzmuran, R; Sikora, J

    1985-03-01

    The possibilities were studied of the practical use of the analytical PIXE method. Calibration samples were analyzed of Cu, Cd, Hg and Pb in concentrations of 50 to 500 ..mu..g/l as well as natural samples of drinking water, pond water, human blood plasma, dry waste from ground vegetation, mushrooms, pine needles, aerosols, human hair, leaves and flowers, etc. The samples were processed using precipitation, mineralization or incineration and were trapped on a membrane filter (Synpor) or on a Tatrafan ON 15 foil. Some samples were freeze-dried and compressed into pellets. A proton beam with an intensity of 10 to 70 nA was used for analysis and the proton energy was selected 2.2 MeV. For most targets an exposure of 120 s was preset and the measurement lasted at least 60 s and 600 s at the most. It was found that Synpor filters browned and became more brittle during longer exposures. The other targets did not change during analysis.

  20. Multielemental analyses of isomorphous Indian garnet gemstones by XRD and external pixe techniques.

    Science.gov (United States)

    Venkateswarulu, P; Srinivasa Rao, K; Kasipathi, C; Ramakrishna, Y

    2012-12-01

    Garnet gemstones were collected from parts of Eastern Ghats geological formations of Andhra Pradesh, India and their gemological studies were carried out. Their study of chemistry is not possible as they represent mixtures of isomorphism nature, and none of the individual specimens indicate independent chemistry. Hence, non-destructive instrumental methodology of external PIXE technique was employed to understand their chemistry and identity. A 3 MeV proton beam was employed to excite the samples. In the present study geochemical characteristics of garnet gemstones were studied by proton induced X-ray emission. Almandine variety of garnet is found to be abundant in the present study by means of their chemical contents. The crystal structure and the lattice parameters were estimated using X-Ray Diffraction studies. The trace and minor elements are estimated using PIXE technique and major compositional elements are confirmed by XRD studies. The technique is found very useful in characterizing the garnet gemstones. The present work, thus establishes usefulness and versatility of the PIXE technique with external beam for research in Geo-scientific methodology. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. External PIXE analysis of old inks and papers

    International Nuclear Information System (INIS)

    Hassanzadeh, A.; Lamehi-Rachti, M.; Oliaiy, P.; Rahighi, J.; Shokouhi, F.

    1999-01-01

    Proton Induced X-ray Emission, PIXE is a very well established analytical method. This technique of analysis can equally be applied both in vacuum, internal PIXE, and in atmosphere, external PIXE. External PIXE has been applied to material analysis in Van de Graaff laboratory at AEOI using filters and funny filters. Advantages of using these filters have been studied when analysing ancient written documents such as envelopes, inks, and newspapers. This technique clearly demonstrated the differences between new and old inks and papers. More data is needed to show other features of this technique. (author)

  2. A new small-footprint external-beam PIXE facility for cultural heritage applications using pulsed proton beams

    Science.gov (United States)

    Vadrucci, M.; Bazzano, G.; Borgognoni, F.; Chiari, M.; Mazzinghi, A.; Picardi, L.; Ronsivalle, C.; Ruberto, C.; Taccetti, F.

    2017-09-01

    In the framework of the COBRA project, elemental analyses of cultural heritage objects based on the particle induced X-ray emission (PIXE) are planned in a collaboration between the APAM laboratory of ENEA-Frascati and the LABEC laboratory of INFN in Florence. With this aim a 3-7 MeV pulsed proton beam, driven by the injector of the protontherapy accelerator under construction for the TOP-IMPLART project, will be used to demonstrate the feasibility of the technique with a small-footprint pulsed accelerator to Italian small and medium enterprises interested in the composition analysis of ancient artifacts. The experimental set-up for PIXE analysis on the TOP-IMPLART machine consists of a modified assembly of the vertical beam line usually dedicated to radiobiology experiments: the beam produced by the injector (RFQ + DTL, a PL7 ACCSYSHITACHI model) is bent to 90° by a magnet, is collimated by a 300 μm aperture inserted in the end nozzle and extracted into ambient pressure by an exit window consisting of a Upilex foil 7.5 μm thick. The beam is pulsed with a variable pulse duration of 20-100 μs and a repetition rate variable from 10 to 100 Hz. The X-ray detection system is based on a Ketek Silicon Drift Detector (SDD) with 7 mm2 active area and 450 μm thickness, with a thin Beryllium entrance window (8 μm). The results of the calibration of this new PIXE set-up using thick target standards and of the analysis of the preliminary measurements on pigments are presented.

  3. Applications of external PIXE to ancient Egyptian artefacts

    International Nuclear Information System (INIS)

    Moser, M.; Bubb, I.F.; Johnston, N.; El Bouanani, M.; Stannard, W.B.; Short, R.C.

    1998-01-01

    The external Proton Induced X-Ray Emission (PIXE) facility at Royal Melbourne Institute of Technology has been used to analyse ancient Egyptian glass samples, an Egyptian wall paint fragment and soil pigments. A 0.35 mm diameter beam of 1.6 MeV protons, extracted from the vacuum through an 8 μm gold coated Kapton foil was used. Analysis of the spectra was carried out with the analysis package PIXAN. The analysis of two Egyptian glass samples enabled the partial determination of the colouring transition metals and the manufacturing technique, indicating them to be consistent with 'New Kingdom' glasses

  4. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F.; Calzolai, G.; Chiari, M.; Mochi, D.; Nava, S. [Department of Physics, University of Florence and INFN, Florence (Italy)

    2013-07-01

    Full text: Particle Induced X-ray Emission (PIXE)technique has been widely used since its birth for the study of the aerosol composition, and for a long time it has been the dominating technique for its elemental analysis. However now it has to compete with other techniques, like Induced Coupled Plasma and detection by Atomic Emission Spectroscopy (ICP-AES) or Mass Spectrometry (ICP-MS) or Synchrotron Radiation XRF (SR-XRF). To remain competitive, a proper experimental set-up is important to fully exploit PIXE capabilities. At LABEC, an external beam line is fully dedicated to PIXE-PIGE measurements of atmospheric aerosols [1]. Recently SDD (Silicon Drift Detectors) have been introduced for X-ray detection thanks to their better resolution with respect to Si(Li) detectors and the possibility of managing high counting rates (up to 50 kHz at 0.5 μsec shaping time). This implies, in turn, the possibility of using very high beam currents thus drastically reducing the measurement time. However their use for a complete characterization of X-rays was limited by the small thickness and surface areas available. Now SDD with a thickness of 500 μm and 80 mm{sup 2} area have been introduced in the market. We have therefore replaced the Si(Li) detector used so far for the detection of medium-high Z elements with such a SDD. A comparison of the two detectors has been carried out; PIXE minimum detection limits (MDLs) at different proton beam energies have been studied to find out the best energy for PIXE measurements on aerosol samples collected on different substrata, namely Teflon, Kapton, Nuclepore and Kimfol, used for daily or hourly sampling or for cascade impactors. In particular in the case of Teflon filters, the production of γ-rays by F in the Teflon filter limits the current which may be used and the Compton γ-ray background worsens the MDLs. Due to the lower thickness of the SDD detector with respect to a typical Si(Li) detector, these problems are reduced

  5. An external proton beam at VERA to study objects of art by proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Kroepfl, P.; Forstner, O.; Kutschera, W.; Priller, A.; Steier, P.; Wallner, A.; Wuenschek, B.; Golser, R.

    2006-01-01

    Full text: PIXE is a very sensitive analytical method to determine the chemical composition of art objects, e.g. drawings, handwritings etc. A particular advantage is the possibility to analyze objects non-destructively under atmospheric pressure. Such an external beam PIXE facility is currently implemented at the Vienna Environmental Research Accelerator (VERA). The set-up allows to extract a 3 MeV proton beam of approximately 100 μm in diameter and currents in the range of a few nA's through an ultra-thin (0.1 μm) Silicon Nitride window. The characteristic x-rays emitted from the specimen are recorded with a Si(Li) and a Silicon Drift detector simultaneously to cover the widest possible Z-range of the detected elements. We have just completed an extensive period of studying beam effects on ancient paper to exclude possible damage to art objects, in particular drawings of the Renaissance that are among the most precious and rarest treasuries of graphical collections. They were created with different materials such as inks, chalks and metal points. A large collection of these fine arts objects is situated at the Albertina in Vienna. Together with scientists from the Centre de Recherche et de Restauration des Musees de France (C2RMF) in Paris, I. Reiche, A. Duval, H. Guicharnaud, from the CEREGE UMR CNRS 6635 in Aix-en-Provence, S. Merchel, from the Albertina in Vienna, E. Thobois, H. Singer, and from the Akademie der bildenden Kuenste in Vienna, M. Schreiner, we want then to analyze a few selected silverpoint drawings by Albrecht Duerer (1471-1528). (author)

  6. Analysis of ancient Indian silver punch-marked coins by external PIXE

    International Nuclear Information System (INIS)

    Rautray, Tapash R.; Nayak, Suman S.; Tripathy, Bipin B.; Das, Saubhagyalaxmi; Das, Manas R.; Das, Satya R.; Chattopadhyay, Pranab K.

    2011-01-01

    Seven silver punch-marked coins were analysed using external particle induced X-ray emission technique. The main group of elements like Ag, Cu, Au, Pb and Fe were estimated along with a number of trace/minor elements such as K, Ca, Ti, V, Cr, Mn, Co, Ni and Rb in the analysed silver coins. Gold was found in all the coins and varied between 0.7% and 6.2% indicating the better economic condition of that civilisation. - Highlights: → The silver punch-marked coins, in the current study, were in use in India between 6th century BC to 6th century AD and have been analysed by in-air PIXE. → These sets of coins have immense archaeological importance because of their very rare availability. → These coins are distinguished from other coins because of the presence of gold as major element. → While the British period coins were fabricated using modern technologies, the punch-marked coins were shaped manually with developed metal technology. → The analysis of punch-marked coins using external PIXE beam has been done for the first time, which is unique of its kind.

  7. External-beam PIXE spectrometry for the study of Punic jewellery (SW Spain): The geographical provenance of the palladium-bearing gold

    International Nuclear Information System (INIS)

    Ontalba Salamanca, M.A.; Gomez-Tubio, B.; Ortega-Feliu, I.; Respaldiza, M.A.; Luisa de la Bandera, M.; Ovejero Zappino, G.; Bouzas, A.; Gomez-Moron, A.

    2006-01-01

    This paper presents the study of a set of Punic gold items (400 B.C.), from the Museum of Cadiz (Spain). An external beam set-up has been employed for the absolutely non-destructive analysis of the objects. PIXE spectrometry has been performed in order to characterize the metallic alloys and the manufacturing techniques. Compositional differences have been found and soldering procedures have been identified. By comparison with the rings and other coetaneous jewellery, the presence of palladium in the bulk alloy of the earrings can be pointed out. The geographical provenance of the palladium-bearing gold is discussed based on geological and archaeological considerations

  8. External-beam PIXE spectrometry for the study of Punic jewellery (SW Spain): The geographical provenance of the palladium-bearing gold

    Energy Technology Data Exchange (ETDEWEB)

    Ontalba Salamanca, M.A. [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda. de la Universidad s/n., 10071 Caceres (Spain)]. E-mail: ontalba@unex.es; Gomez-Tubio, B. [Centro Nacional de Aceleradores, Sevilla (Spain); Ortega-Feliu, I. [Centro Nacional de Aceleradores, Sevilla (Spain); Respaldiza, M.A. [Centro Nacional de Aceleradores, Sevilla (Spain); Luisa de la Bandera, M. [Departamento de Arqueologia, Universidad de Sevilla (Spain); Ovejero Zappino, G. [Cobre Las Cruces SA, Gerena, Sevilla (Spain); Bouzas, A. [Instituto Andaluz de Patrimonio Historico, Sevilla (Spain); Gomez-Moron, A. [Instituto Andaluz de Patrimonio Historico, Sevilla (Spain)

    2006-08-15

    This paper presents the study of a set of Punic gold items (400 B.C.), from the Museum of Cadiz (Spain). An external beam set-up has been employed for the absolutely non-destructive analysis of the objects. PIXE spectrometry has been performed in order to characterize the metallic alloys and the manufacturing techniques. Compositional differences have been found and soldering procedures have been identified. By comparison with the rings and other coetaneous jewellery, the presence of palladium in the bulk alloy of the earrings can be pointed out. The geographical provenance of the palladium-bearing gold is discussed based on geological and archaeological considerations.

  9. Coupled PIXE and RBS using a 6MeV 4He2+ external beam: A new experimental device for particle detection and dose monitoring

    International Nuclear Information System (INIS)

    Mathis, F.; Moignard, B.; Pichon, L.; Dubreuil, O.; Salomon, J.

    2005-01-01

    AGLAE (Accelerateur Grand Louvre d'Analyses Elementaire), the IBA facility of the 'Centre de Recherche et de Restauration des Musees de France' (C2RMF) has been equipped for several years with an external micro-beam line, in order to perform ion beam analysis on materials relevant to cultural heritage. This beam line is undergoing constant improvement. Recently, a new extraction nozzle for the external beam of the accelerator has been designed in order to obtain simultaneously from the same spot: - detection of the X-ray emission by two detectors, for low and high energies; - detection of the backscattered particles for a backscattering angle between 170 and 175 deg., thanks to an annular surface barrier detector included in the nozzle; - particle current monitoring by intermittent beam deflection on a reference material included in the system. This technical development has been induced by the study of artificial patinas on archaeological copper-alloy objects and the attempt to characterize them with a 6MeV 4 He 2+ beam, an unusual beam for this type of investigation. A detailed description of the new device and some results on an application of the use of high-energy alpha beam in PIXE and RBS made on a Roman strigil are presented here

  10. External PIXE analysis of an Iranian 15th century poetry book

    Energy Technology Data Exchange (ETDEWEB)

    Kakuee, Omidreza, E-mail: okakuee@aeoi.org.ir [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Taheri, Raziyeh; Jafarian, Hosseinali A. [The Library, Museum and Documentation Center of the Islamic Republic of Iran Parliament, Tehran (Iran, Islamic Republic of)

    2012-02-15

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135 Degree-Sign while the beam charge was indirectly measured through the Ar K{sub {alpha}} X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  11. External PIXE analysis of an Iranian 15th century poetry book

    International Nuclear Information System (INIS)

    Kakuee, Omidreza; Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad; Taheri, Raziyeh; Jafarian, Hosseinali A.

    2012-01-01

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135° while the beam charge was indirectly measured through the Ar K α X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  12. External-RBS, PIXE and NRA analysis for ancient swords

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Hellen C., E-mail: hellencsa@gmail.com; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-02-15

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  13. External-RBS, PIXE and NRA analysis for ancient swords

    Science.gov (United States)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C. L.

    2015-02-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi - São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  14. External-RBS, PIXE and NRA analysis for ancient swords

    International Nuclear Information System (INIS)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-01-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility

  15. Study of Z > 18 elements concentration in tree rings from surroundings forests of the Mexico Valley using external beam PIXE

    International Nuclear Information System (INIS)

    Calva-Vazquez, G.; Razo-Angel, G.; Rodriguez-Fernandez, L.; Ruvalcaba-Sil, J.L.

    2006-01-01

    The concentration of elements with Z > 18 is measured in tree rings from forests at the surroundings of the Mexico Valley: El Chico National Park (ECP) and Desierto de los Leones National Park (DLP). The analysis was done by simultaneous PIXE-RBS using an external proton beam on tree rings of Pine and Sacred fir (species Pinus montezumae and Abies religiosa, respectively). This study provides information about the elemental concentration in trees of those parks during the years from 1965 to 2003. Typical elements such as K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr and Pb were detected using PIXE technique while the wood matrix composition (mainly C and O) was determined by RBS. In general, elemental contents present large variations but concentrations oscillate around the mean value during this period of time. Nevertheless, the measurements showed some trends for Fe and Zn in the tree-rings elemental composition that may be correlated to recent volcanic activities in the region. The low Mn contents indicate soil acidification in DLP from 1968 and the forest decline in ECP during the last 15 years

  16. External-beam PIXE characterization of volcanic material used in ancient Roman mortars

    International Nuclear Information System (INIS)

    Sonck-Koota, P.; Lindroos, A.; Lill, J.-O.; Rajander, J.; Viitanen, E.-M.; Marra, F.; Pehkonen, M.H.; Suksi, J.; Heselius, S.-J.

    2008-01-01

    Volcanic deposits from two volcanic districts, Monti Sabatini (MSVD) and Colli Albani (CAVD), NW and SE of Rome, were analyzed using the particle-induced X-ray emission (PIXE) technique, in order to obtain chemical fingerprints that can be used for provenance studies of filler materials in ancient Roman mortars. The rock samples were mounted on an X-Y stage enabling scanning over the sample surface and irradiated in air with a collimated 3 MeV proton beam. The samples were either analyzed by scanning the beam over a polished surface or they were crushed, ground and homogenized prior to the irradiation. However, scanning over polished sample surfaces avoiding heterogeneities gave quite similar results as scanning over pellet surfaces, especially for the minor and trace elements. This study shows that the deposits of MSVD and CAVD can be distinguished from each other. Several elements or elemental ratios can be used to characterize the districts. Even the individual volcanic deposits of CAVD can be identified

  17. Evaluation by PIXE external beam-of the leaching efficiency for a thermo stated column for the sand treatment

    International Nuclear Information System (INIS)

    Aspiazu, J.; Vite, J.; Vivero, R.; Mendez, B.

    1995-01-01

    The purpose of this paper was to measure the leaching efficiency for a thermo stated column designed to extract metals in muds originated by foundry process. The results obtained were useful to contemplate different alternatives helping to solve the problem of stocking enormous volumes of polluted sand produced by industries. Samples of residual sands and muds (treated sands) coming from an engine factory and from a thermo stated column respectively, were irradiated using an external beam of 3.55 MeV energy protons. From the quantitative analysis PIXE (Proton Induced X-ray Emission), it was possible to establish the level of pollution in sands due to the foundry processes and to evaluate the leaching efficiency of the output liquid phase from the thermo stated column. For polluted sands, certain cases were observed for which the efficiency was not enough to decrease the level of pollution in, e.g., Cu, Zn, Br and Pb. (Author)

  18. Evaluation by PIXE external beam of the leaching efficiency for a thermo stated column for the sand treatment

    International Nuclear Information System (INIS)

    Aspiazu, J.; Vite, J.; Vivero, R.; Mendez, B.

    1995-01-01

    The purpose of this paper was to measure the leaching efficiency for a thermo stated column designed to extract metals in muds originated by foundry processes. The results obtained were useful to contemplate different alternatives helping to solve the problem of stocking enormous volumes of polluted sand produced by industries. Samples of residual sands and muds (treated sands) coming from an engine factory and from a thermo stated column respectively, were irradiated using an external beam of 3.55 MeV energy protons. From the quantitative analysis PIXE (Proton Induced X-ray Emission), it was possible to establish the level of pollution in sands due to the foundry processes and to evaluate the leaching efficiency of the output liquid phase from the thermo stated column. For polluted sands, certain cases were observed for which the efficiency was not enough to decrease the level of pollution in e.g., Cu, Zn, Br y Pb. (Author)

  19. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  20. Non-destructive provenance differentiation of prehistoric pigments by external PIXE

    International Nuclear Information System (INIS)

    Beck, L.; Salomon, H.; Lahlil, S.; Lebon, M.; Odin, G.P.; Coquinot, Y.; Pichon, L.

    2012-01-01

    The elemental analysis of minerals/rocks has been often used for the determination of their geological origin. When these natural rocks were exploited by prehistoric civilizations as objects, weapons, or pigments, the composition of the minerals can provide information on the mobility, the exchanges and the interaction between groups of population. In this paper, we will present results obtained from archaeological samples of prehistoric pigments, mainly iron and manganese oxides. PIXE analysis has been applied to samples of the prehistoric cave “La grotte du Renne” in Arcy-sur-Cure, France (Chatelperronian, 38,000–34,000 BP). Because most of the archaeological objects are decorated or display some use marks, it is not possible to take samples. Consequently, we have used a non-destructive technique thanks to the external beam of AGLAE (C2RMF, Paris). In order to improve the limits of detection (LOD less than 10 ppm from Cu to Sb), a metal absorber has been placed on the X-ray detector to preferentially filter the Fe–K or Mn–K lines. Based on the quantitative analysis of major and trace elements, we have obtained groups of compositions corresponding to different geological sources. We demonstrate in this study that it is possible to extend PIXE analysis to the characterization of prehistoric pigments such as iron and manganese oxides for differentiating potential sources of pigments in archaeological contexts.

  1. PIXE study on the provenance of Chinese ancient porcelain

    International Nuclear Information System (INIS)

    Zhu, D.; Cheng, H.S.; Lin, J.W.; Yang, F.J.

    2006-01-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE

  2. PIXE study on the provenance of Chinese ancient porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Lin, J.W. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)

    2006-08-15

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  3. PIXE study on the provenance of Chinese ancient porcelain

    Science.gov (United States)

    Zhu, D.; Cheng, H. S.; Lin, J. W.; Yang, F. J.

    2006-08-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  4. GridPix detectors: Production and beam test results

    International Nuclear Information System (INIS)

    Koppert, W.J.C.; Bakel, N. van; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; Graaf, H. van der; Hartjes, F.; Hessey, N.P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-01-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip

  5. GridPix detectors: Production and beam test results

    Science.gov (United States)

    Koppert, W. J. C.; van Bakel, N.; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; van der Graaf, H.; Hartjes, F.; Hessey, N. P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-12-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip.

  6. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  7. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    Energy Technology Data Exchange (ETDEWEB)

    Pichon, L., E-mail: laurent.pichon@culture.fr [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); PSL Research University, Chimie ParisTech-CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Lemasson, Q.; Moignard, B.; Pacheco, C. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.

  8. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    International Nuclear Information System (INIS)

    Pichon, L.; Calligaro, T.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.

  9. Development and Commissioning of an External Beam Facility in the Union College Ion Beam Analysis Laboratory

    Science.gov (United States)

    Yoskowitz, Joshua; Clark, Morgan; Labrake, Scott; Vineyard, Michael

    2015-10-01

    We have developed an external beam facility for the 1.1-MV tandem Pelletron accelerator in the Union College Ion Beam Analysis Laboratory. The beam is extracted from an aluminum pipe through a 1 / 4 ' ' diameter window with a 7.5- μm thick Kapton foil. This external beam facility allows us to perform ion beam analysis on samples that cannot be put under vacuum, including wet samples and samples too large to fit into the scattering chamber. We have commissioned the new facility by performing proton induced X-ray emission (PIXE) analysis of several samples of environmental interest. These include samples of artificial turf, running tracks, and a human tooth with an amalgam filling. A 1.7-MeV external proton beam was incident on the samples positioned 2 cm from the window. The resulting X-rays were measured using a silicon drift detector and were analyzed using GUPIX software to determine the concentrations of elements in the samples. The results on the human tooth indicate that while significant concentrations of Hg, Ag, and Sn are present in the amalgam filling, only trace amounts of Hg appear to have leached into the tooth. The artificial turf and running tracks show rather large concentrations of a broad range of elements and trace amounts of Pb in the turf infill.

  10. Combined external-beam PIXE and {mu}-Raman characterisation of garnets used in Merovingian jewellery

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: thomas.calligaro@culture.gouv.fr; Colinart, S.; Poirot, J.-P.; Sudres, C

    2002-04-01

    Red garnets were the dominant gemstones used for jewels in Europe during the Early Middle Ages. We have studied over 350 garnets set on 12 jewels unearthed in the royal necropolis of the Saint-Denis Basilica, close to Paris. This famous collection of 'cloisonne' style artefacts dates from the Merovingian period (late fifth century AD to early seventh century AD). The archaeological issue addressed is the identification of the geographical origin of these garnets, in view to establish the gem trading routes during the Dark Ages. External beam PIXE was used to determine the major constituents (Mg, Al, Si, Ca, Mn, Fe), specifying the garnet type (composition in various mineralogical end-members, e.g. almandine, pyrope, spessartite, ...), and the trace element content (Cr, Y). Three sorts of garnets were identified. Ten jewels are adorned with almandine garnets (Fe-rich). One jewel has intermediate almandine-pyrope garnets ('rhodolite'). The last and most recent jewel is inlaid with pyrope (Mg-rich) garnets. Trace element content and slight differences in major composition allowed to distinguish five different sources: two sources for pyrope garnets (with and without chromium), and two sources for almandine garnets (distinctive calcium, magnesium and yttrium contents). A preliminary comparison with literature data suggested that almandine garnets may have been mined from India while the 'rhodolite' garnets may have been imported from Sri Lanka. The sources of pyrope garnets could be the Bohemian deposits (Czech republic). In addition, {mu}-Raman spectrometry was used to identify most of the mineral inclusions (apatite, zircon, ilmenite, monazite, calcite, quartz) present in almandine garnets. Even if two specific types of inclusions were not identified, due to the lack of corresponding reference spectra in our database, the Raman spectra collected provided an interesting inclusion fingerprint.

  11. Applications of PIXE in dendrochronology

    International Nuclear Information System (INIS)

    Revesz, P.; Mayer, J.W.; Vizkelethy, G.; Kuniholm, P.I.; Griggs, C.B.; Kuniholm, H.E.; Newton, M.W.; Tarter, S.L.

    1991-01-01

    The Bard Hall Ion Beam Facility has developed external proton beams at 1-3 MeV for ion-induced x-ray emission studies of artists' pigments and metallic printers inks. The authors have extended these PIXE measurements to analysis of Athenian Tetradrachms (5th and 6th centuries BC). In both pigment and coin studies they have compared PIXE analyses with those from XRF and electron micro probe for calibration purposes. The Aegean Dendrochronology Project has developed over 5500 years of tree-ring chronologies for the Aegean, Balkans, and Eastern Mediterranean. Included are forest sites adjacent to mining and smelting operations, also sites at the upper timberline where the annual growth-rings might be expected to have picked up fallout from volcanic activity around the world. A preliminary examination of selected rings by PIXE has shown remarkable differences from year to year in the deposition of various elements, notable Zn, Fe, and Cu. The authors propose to look at a number of selected annual ring sequences to see (1) whether one can chart the progress of known metallurgical activity; (2) whether one can find evidence for volcanic effects, both for absolutely-dated volcanoes such as Krakatoa, Tambora, and Sumbawa, and for problematic volcanoes such as Santorini/Thera

  12. Quantitative analysis of ancient Egyptian pigments by external PIXE

    International Nuclear Information System (INIS)

    Uda, M.; Tsunokami, T.; Murai, R.; Maeda, K.; Harigai, I.; Nakayama, Y.; Yoshimura, S.; Kikuchi, T.; Sakurai, K.; Sasa, Y.

    1993-01-01

    Pigments painted on Egyptian excavations in the 18th Dynasty were analyzed successfully by external PIXE with the aid of the X-ray diffraction. A white pigment was composed on Mg 3 Ca(CO 3 ) 4 ; red: αFe 2 O 3 , αFeO.OH and AsS; pink: Mixtures of white and red pigments; yellow: αFeO.OH and As 2 S 3 ; and blue: CaO.CuO.4SiO 2 . (orig.)

  13. The external beam facility used to characterize corrosion products in metallic statuettes

    International Nuclear Information System (INIS)

    Rizzutto, M.A.; Tabacniks, M.H.; Added, N.; Barbosa, M.D.L.; Curado, J.F.; Santos, W.A.; Lima, S.C.; Melo, H.G.; Neiva, A.C.

    2005-01-01

    To open new possibilities in nuclear applied physics research, mainly for the analysis of art objects in air, an external beam facility was installed at LAMFI (Laboratorio de Analise de Materiais por Feixes Ionicos) of University of Sao Paulo. PIXE measurements were made using an XR-100CR (Si-PIN) X-ray detector pointed to the sample mounted after an approximate 11 mm air path, hence with effective beam energy of 0.9 MeV. This setup was used to characterize the corrosion products of two ethnological metallic statuettes from the African collection of the Museum of Archaeology and Etnology. PIXE analysis of the corrosion free base of one statuette showed that Cu and Zn are the main components of the alloy, while Pb is present in smaller amount. The analysis of some corrosion products showed a Zn:Cu relationship higher than that of the base, evidencing selective corrosion. The main components of the other statuette were Cu and Pb, while S and Zn were found in smaller amounts

  14. Internal/external mixing of aerosol particles elemental composition retrieved from microPIXE and PIXE

    International Nuclear Information System (INIS)

    Ghermandi, G.; Cecchi, R.; Lusvarghi, L.; Laj, P.; Zappoli, S.; Ceccato, D.

    2005-01-01

    A statistical evaluation of the association between different elements contained in atmospheric aerosol particles has been made using the microPIXE technique. We derived elemental maps of Al, Si, S, Ca, Cl, K, Fe, Mg spatial distribution on the surface of a Nuclepore filter sample. The microPIXE measurements are validated by comparison to conventional PIXE and SEM-EDAX. Then, the spatial coherence of the different elements is analysed using statistical methods. The elements are not homogeneously distributed and the association among specific elements can be identified. MicroPIXE and factorial analysis can be coupled to understand the state of mixing of the different elements on the filter surface

  15. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    International Nuclear Information System (INIS)

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  16. PIXE analysis of Zn enzymes

    International Nuclear Information System (INIS)

    Solis, C.; Oliver, A.; Andrade, E.; Ruvalcaba-Sil, J.L.; Romero, I.; Celis, H.

    1999-01-01

    Zinc is a necessary component in the action and structural stability of many enzymes. Some of them are well characterized, but in others, Zn stoichiometry and its association is not known. PIXE has been proven to be a suitable technique for analyzing metallic proteins embedded in electrophoresis gels. In this study, PIXE has been used to investigate the Zn content of enzymes that are known to carry Zn atoms. These include the carbonic anhydrase, an enzyme well characterized by other methods and the cytoplasmic pyrophosphatase of Rhodospirillum rubrum that is known to require Zn to be stable but not how many metal ions are involved or how they are bound to the enzyme. Native proteins have been purified by polyacrylamide gel electrophoresis and direct identification and quantification of Zn in the gel bands was performed with an external proton beam of 3.7 MeV energy

  17. Improvements in PIXE analysis of hourly particulate matter samples

    Energy Technology Data Exchange (ETDEWEB)

    Calzolai, G., E-mail: calzolai@fi.infn.it [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Lucarelli, F. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M.; Nava, S. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Giannoni, M. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy); Carraresi, L. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Prati, P. [Department of Physics, University of Genoa and INFN Division of Genoa, Via Dodecaneso 33, 16146 Genoa (Italy); Vecchi, R. [Department of Physics, Università degli Studi di Milano and INFN Division of Milan, Via Celoria 16, 20133 Milan (Italy)

    2015-11-15

    Most air quality studies on particulate matter (PM) are based on 24-h averaged data; however, many PM emissions as well as their atmospheric dilution processes change within a few hours. Samplings of PM with 1-h resolution can be performed by the streaker sampler (PIXE International Corporation), which is designed to separate the fine (aerodynamic diameter less than 2.5 μm) and the coarse (aerodynamic diameter between 2.5 and 10 μm) fractions of PM. These samples are efficiently analyzed by Particle Induced X-ray Emission (PIXE) at the LABEC laboratory of INFN in Florence (Italy), equipped with a 3 MV Tandetron accelerator, thanks to an optimized external-beam set-up, a convenient choice of the beam energy and suitable collecting substrates. A detailed description of the adopted set-up and results from a methodological study on the detection limits for the selection of the optimal beam energy are shown; the outcomes of the research on alternative collecting substrates, which produce a lower background during the measurements, and with lower contaminations, are also discussed.

  18. PIXE-PIGE analysis of late roman glass fragments

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Tubio, B. [Departamento de Fisica Aplicada III, Escuela de Ingenieros, Universidad de Sevilla, Camino de los Descubrimientos s/n, 41092 Sevilla (Spain)]. E-mail: tubio@us.es; Ontalba Salamanca, M.A. [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda. de la Universidad s/n, 10071 Caceres (Spain); Ortega-Feliu, I. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Respaldiza, M.A. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Amores Carredano, F. [Departamento de Prehistoria y Arqueologia, Universidad de Sevilla, C/Dona Maria de Padilla s/n, 41010 Sevilla (Spain); Gonzalez-Acuna, D. [Departamento de Geografia, Historia y Filosofia, Universidad Pablo de Olavide, Ctra. de Utrera Km 1, 41013 Sevilla (Spain)

    2006-08-15

    A set of Roman glass fragments, excavated at Sevilla and dated in the 5th century A.D., has been analysed by PIXE and PIGE techniques using the external beam set-up of the 3 MV tandem Pelletron accelerator of the CNA at the University of Sevilla. Using a simple quantification method, based on the indirect charge calculation on the sample by monitoring the X-ray induced by the proton beam on the exit window, the composition of the glasses has been determined. From the obtained results, the use of soda as flux has been inferred and colouring manufacture procedures have been identified.

  19. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  20. Uncertainties in thick-target PIXE analysis

    International Nuclear Information System (INIS)

    Campbell, J.L.; Cookson, J.A.; Paul, H.

    1983-01-01

    Thick-target PIXE analysis insolves uncertainties arising from the calculation of thick-target X-ray production in addition to the usual PIXE uncertainties. The calculation demands knowledge of ionization cross-sections, stopping powers and photon attenuation coefficients. Information on these is reviewed critically and a computational method is used to estimate the uncertainties transmitted from this data base into results of thick-target PIXE analyses with reference to particular specimen types using beams of 2-3 MeV protons. A detailed assessment of the accuracy of thick-target PIXE is presented. (orig.)

  1. PIXE in cultural heritage studies: present role and new challenges

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. [Centre de Recherche et de Restauration des Musées de France, Palais du Louvre, Paris (France)

    2013-07-01

    Full text: The non-destructive study of artistic and archaeological objects relies on the use of a large panel of modern analytical tools. Among them, PIXE plays a prominent role due to its almost unique combination of excellent analytical features in terms of sensitivity and accuracy combined with a non-destructive and even non-invasive character. the latter advantage stems from extensive instrumental progress - like the external beam - carried out since the advent of PIXE in the 1970s to account for the precious and unique nature of artworks and archaeological artifacts that preclude any sampling or damage. the situation has however evolved in the recent years as several competing techniques providing non-destructively the chemical composition have arisen, which more or less shake the privileged status of PIXE. On one hand, analytical techniques implemented with tabletop or movable XRF instruments have been massively developed, which allow in situ analysis and represent a progress in terms of artworks safety and flexibility of analysis. On the other hand, access to synchrotron radiation facilities is becoming easier and therefore the use of the powerful X-ray absorption techniques (XANES, EXAFS), that add chemical environment information to the elemental analysis, is progressively gaining popularity. Considering these trends, it seems important to reassess the place of PIXE in the field of art and archaeology and to underline its specific assets. the aim of this article is to pinpoint the situation where PIXE is the best analytical tool with regard to the specificity of art and archaeological items and to stress the new challenges it will have to face. Case studies carried out with the AGLAE facility of the C2RMF will illustrate the situations where PIXE exhibits specific advantages: Light element measurement. The high ionization cross section of light elements by charged particles favors the accurate measurement of sodium, magnesium, aluminum and silicon, whose

  2. PIXE in cultural heritage studies: present role and new challenges

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.

    2013-01-01

    Full text: The non-destructive study of artistic and archaeological objects relies on the use of a large panel of modern analytical tools. Among them, PIXE plays a prominent role due to its almost unique combination of excellent analytical features in terms of sensitivity and accuracy combined with a non-destructive and even non-invasive character. the latter advantage stems from extensive instrumental progress - like the external beam - carried out since the advent of PIXE in the 1970s to account for the precious and unique nature of artworks and archaeological artifacts that preclude any sampling or damage. the situation has however evolved in the recent years as several competing techniques providing non-destructively the chemical composition have arisen, which more or less shake the privileged status of PIXE. On one hand, analytical techniques implemented with tabletop or movable XRF instruments have been massively developed, which allow in situ analysis and represent a progress in terms of artworks safety and flexibility of analysis. On the other hand, access to synchrotron radiation facilities is becoming easier and therefore the use of the powerful X-ray absorption techniques (XANES, EXAFS), that add chemical environment information to the elemental analysis, is progressively gaining popularity. Considering these trends, it seems important to reassess the place of PIXE in the field of art and archaeology and to underline its specific assets. the aim of this article is to pinpoint the situation where PIXE is the best analytical tool with regard to the specificity of art and archaeological items and to stress the new challenges it will have to face. Case studies carried out with the AGLAE facility of the C2RMF will illustrate the situations where PIXE exhibits specific advantages: Light element measurement. The high ionization cross section of light elements by charged particles favors the accurate measurement of sodium, magnesium, aluminum and silicon, whose

  3. PIXE and ion beam analysis in forensics

    International Nuclear Information System (INIS)

    Bailey, Melanie; Warmenhoven, John; Chrislopher, Matt; Kirkby, Karen; Palitsin, Vladimir; Grime, Geoff; Jeynes, Chris; Jones, Brian; Wenn, Roger

    2013-01-01

    Full text: University of Surrey has, for the past four years, collaborated with police institutions from across Europe and the rest of the world lo scope potential applications of ion beam analysis (IBA) in forensic science. In doing this we have consulted practitioners across a range of forensic disciplines, and critically compared IBA with conventional characterisation techniques to investigate the areas in which IBA can add evidential value. In this talk, the results of this feasibility study will be presented, showing the types of sample for which IBA shows considerable promise. We will show how a combination of PIXE with other IBA techniques (EBS, PIGE, MeV-SIMS) can be used to give unprecedented characterisation of forensic samples and comment on the significance of these results for forensic casework. We will also show cases where IBA not appear to add any significant improvement over conventional techniques. (author)

  4. PIXE analysis of nephrite minerals from different deposits

    Science.gov (United States)

    Zhang, Z. W.; Gan, F. X.; Cheng, H. S.

    2011-02-01

    External-beam PIXE was used to determine the major, minor and trace elements of 45 nephrite minerals from 14 different deposits, including China and other countries. Depending on the R∗ value (mole percent of Mg 2+/(Mg 2+ + Fe 2+(3+))) and content of Cr, Co and Ni, two types of nephrite minerals from dolomite and serpentinized ultramafic deposits can be more accurately distinguished. Besides, the nephrite minerals from Xiaomeiling and Wenchuan deposit can be distinguished with others from dolomite deposits, through the content of Sr and Mn/Fe value, respectively. Moreover, depending on the Sr content, clear evidence was given to prove that the raw materials of ancient nephrite artifacts from Liangzhu culture ruins are not from Xiaomeiling nephrite deposit. Furthermore, PIXE as a non-destructive method will be more used to study ancient nephrite artifacts, so these results can provide scientific basis for seeking the provenance of nephrite raw materials.

  5. Development of a multi-detector and a systematic imaging system on the AGLAE external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Moignard, B.; Lemasson, Q.; Pacheco, C.; Walter, P.

    2014-01-01

    The New AGLAE external beamline provides analytical data for the understanding of the structure of archaeological and artistic objects, their composition, properties, and changes over time. One of the objectives of this project is to design and set up a new non-invasive acquisition system increasing the quality of the X-ray spectra and reducing the beam current on sensitive materials from work of art. To that end, the surface and the number of PIXE detectors have been increased to implement a cluster of SDD detectors. This can also provide the possibility to accomplish large and/or fast maps on artifacts with a scanning of the beam on the sample. During the mapping, a multi-parameter system saves each event from X-ray, gamma and particle detectors, simultaneously with the X and Y positions of the beam on the sample. To process the data, different softwares have been developed or updated. A first example on a decorated medieval shard highlights the perspectives of the technique

  6. Development of a multi-detector and a systematic imaging system on the AGLAE external beam

    Energy Technology Data Exchange (ETDEWEB)

    Pichon, L., E-mail: laurent.pichon@culture.gouv.fr [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); Moignard, B.; Lemasson, Q.; Pacheco, C. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); Walter, P. [Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); UPMC Univ Paris 06, CNRS-UMR 8220, Laboratoire d’archéologie moléculaire et structurale, LAMS, F-75005 Paris (France)

    2014-01-01

    The New AGLAE external beamline provides analytical data for the understanding of the structure of archaeological and artistic objects, their composition, properties, and changes over time. One of the objectives of this project is to design and set up a new non-invasive acquisition system increasing the quality of the X-ray spectra and reducing the beam current on sensitive materials from work of art. To that end, the surface and the number of PIXE detectors have been increased to implement a cluster of SDD detectors. This can also provide the possibility to accomplish large and/or fast maps on artifacts with a scanning of the beam on the sample. During the mapping, a multi-parameter system saves each event from X-ray, gamma and particle detectors, simultaneously with the X and Y positions of the beam on the sample. To process the data, different softwares have been developed or updated. A first example on a decorated medieval shard highlights the perspectives of the technique.

  7. The quantitative analysis of 163Ho source by PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Ishii, K.; Fujioka, M.; Izawa, G.; Omori, T.

    1984-01-01

    We have been studying the electron-capture in 163 Ho as a method for determining the mass of electron neutrino. The 163 Ho sources were produced with the 164 Dy(p,2n) reaction by means of a method of internal irradiation 2 ). We applied the PIXE method to determine the total number of 163 Ho atoms in the source. Proton beams of 3 MeV and a method of ''external standard'' were employed for nondestructive analysis of the 163 Ho source as well as an additional method of ''internal standard''. (author)

  8. Paintings on copper by the Flemish artist Frans Francken II: PIXE characterization by external microbeam

    International Nuclear Information System (INIS)

    Corregidor, V.; Oliveira, A.R.; Rodrigues, P.A.; Alves, L.C.

    2015-01-01

    Resorting to an external proton microbeam, PIXE analyses of three oil paintings on copper support dated from the XVII century and attributed to the Flemish artist Frans Francken II, were undertaken. The present work aims to contribute to the compositional study of the painting materials employed by XVII century artists that exploited copper as a support for oil painting, and specifically the materials used by Francken’s workshop, particularly copper plates. Because of the low thickness of the pictorial layers of this type of paintings and its non-destructive character, PIXE is the ideal technique to study the elemental composition of the paintings. Several spots in each painting were chosen for analysis in order to cover almost all the pigments used in the colour palette. Lead and calcium were detected in practically every analysed regions, probably related to the presence of lead white and chalk, usually used as ground layer on copper paintings. Small quantities of gold were also detected, which is present in many of this artist’s works to embellish some details of the representations. Also this work reports the first application of the external proton microbeam set-up available at CTN/IST in Portugal for the characterization of oil paintings

  9. 3D Micro-PIXE at atmospheric pressure: A new tool for the investigation of art and archaeological objects

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit; Karydas, Andreas-Germanos; Schuetz, Roman; Sokaras, Dimosthenis; Reiche, Ina; Roehrs, Stefan; Pichon, Laurent; Salomon, Joseph

    2007-01-01

    The paper describes a novel experiment characterized by the development of a confocal geometry in an external Micro-PIXE set-up. The position of X-ray optics in front of the X-ray detector and its proper alignment with respect to the proton micro-beam focus provided the possibility of carrying out 3D Micro-PIXE analysis. As a first application, depth intensity profiles of the major elements that compose the patina layer of a quaternary bronze alloy were measured. A simulation approach of the 3D Micro-PIXE data deduced elemental concentration profiles in rather good agreement with corresponding results obtained by electron probe micro-analysis from a cross-sectioned patina sample. With its non-destructive and depth-resolving properties, as well as its feasibility in atmospheric pressure, 3D Micro-PIXE seems especially suited for investigations in the field of cultural heritage

  10. A new external microbeam system in Fudan University

    International Nuclear Information System (INIS)

    Zheng, Y.; Shen, H.; Li, Y.Q.; Li, X.Y.; Yang, M.J.; Mi, Y.

    2013-01-01

    A cost-effective and removable external beam system is set up based on the Oxford Microbeam system in Fudan University. In our external beam system, 7.5-μm-thick Kapton film is used as exit window with a diameter of 3.5 mm. The spatial resolution is about 18 μm full width at half maximum (FWHM) on a copper grid. As an example, calcium distribution in otolith is present by the external micro-PIXE. In addition, little change can be done to the external system mentioned above for radiobiology experiments. The exit window can be changed from the focal plane to the observation window of vacuum chamber. By calculation, the beam spot size can reach less than 30 μm. Since the Oxford type octagonal target chamber is popular among the nuclear microprobe facilities, this method can be provided to easily replace the in-vacuum system with the external system, extending the in-vacuum analysis to external beam analysis

  11. A new external microbeam system in Fudan University

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Y.; Shen, H., E-mail: haoshen@fudan.edu.cn; Li, Y.Q.; Li, X.Y.; Yang, M.J.; Mi, Y.

    2013-07-01

    A cost-effective and removable external beam system is set up based on the Oxford Microbeam system in Fudan University. In our external beam system, 7.5-μm-thick Kapton film is used as exit window with a diameter of 3.5 mm. The spatial resolution is about 18 μm full width at half maximum (FWHM) on a copper grid. As an example, calcium distribution in otolith is present by the external micro-PIXE. In addition, little change can be done to the external system mentioned above for radiobiology experiments. The exit window can be changed from the focal plane to the observation window of vacuum chamber. By calculation, the beam spot size can reach less than 30 μm. Since the Oxford type octagonal target chamber is popular among the nuclear microprobe facilities, this method can be provided to easily replace the in-vacuum system with the external system, extending the in-vacuum analysis to external beam analysis.

  12. A new external microbeam system in Fudan University

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Shen, H., E-mail: haoshen@fudan.edu.cn [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Li, Y.Q.; Li, X.Y.; Yang, M.J.; Mi, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2013-02-01

    A cost-effective and removable external beam system is set up based on the Oxford Microbeam system in Fudan University. In our external beam system, 7.5-μm-thick Kapton film is used as exit window with a diameter of 3.5 mm. The spatial resolution is about 18 μm full width at half maximum (FWHM) on a copper grid. As an example, calcium distribution in otolith is present by the external micro-PIXE. In addition, little change can be done to the external system mentioned above for radiobiology experiments. The exit window can be changed from the focal plane to the observation window of vacuum chamber. By calculation, the beam spot size can reach less than 30 μm. Since the Oxford type octagonal target chamber is popular among the nuclear microprobe facilities, this method can be provided to easily replace the in-vacuum system with the external system, extending the in-vacuum analysis to external beam analysis.

  13. Proton beam modification of lead white pigments

    International Nuclear Information System (INIS)

    Beck, L.; Gutiérrez, P.C.; Miserque, F.; Thomé, L.

    2013-01-01

    Pigments and paint materials are known to be sensitive to particle irradiation. Occasionally, the analysis of paintings by PIXE can induce a slight or dark stain depending on the experimental conditions (beam current, dose, particle energy). In order to understand this discoloration, we have irradiated various types of art white pigments – lead white (hydrocerussite and basic lead sulfate), gypsum, calcite, zinc oxide and titanium oxide – with an external 3 MeV proton micro-beam commonly used for PIXE experiments. We have observed various sensitivities depending on the pigment. No visible change occurs for calcite and titanium oxide, whereas lead white pigments are very sensitive. For the majority of the studied compounds, the discoloration is proportional to the beam current and charge. The damage induced by proton beam irradiation in lead white pigments was studied by micro-Raman and XPS spectroscopies. Structural modifications and dehydration were detected. Damage recovery was investigated by thermal treatment and UV-light irradiation. The discoloration disappeared after one week of UV illumination, showing that PIXE experiments could be safely undertaken for pigments and paintings

  14. Exploring advantages of 4He-PIXE analysis for layered objects in cultural heritage

    International Nuclear Information System (INIS)

    Roehrs, S.; Calligaro, T.; Mathis, F.; Ortega-Feliu, I.; Salomon, J.; Walter, P.

    2006-01-01

    In the field of cultural heritage 4 He particle beams are often used to perform RBS analysis. In most cases the simultaneously produced X-rays are not considered for PIXE analysis. This paper aims to explore the potentials of 4 He induced X-ray emission (α-PIXE) using 4, 5 and 6 MeV 4 He beams and to compare its performance with that of conventional PIXE with 3 MeV protons. The α-PIXE and α-RBS spectra were collected at the same time in a vacuum chamber. The X-ray yields produced by 6 MeV 4 He beam for K-lines were found to be superior to those of protons for atomic numbers below 25. An additional advantage of α-PIXE is the lower bremsstrahlung background which leads to an improved peak to noise ratio for certain elements

  15. Investigation of in vivo PIXE effect within superficial tumor model of high-Z metalnanoplatform for PIXE-based proton therapy

    International Nuclear Information System (INIS)

    Kim, Jong Ki; Seo, Seung Jun; Lee, Ju Hong

    2010-04-01

    Metallic nanoparticles (MNP) are able to release localized X-ray when activated with high energy proton beam by particle induced X-ray emissions (PIXE) effect. The exploitation of this phenomenon in the therapeutic irradiation of tumors has been investigated. PIXE-based X-ray emission directed at CT-26 tumor cells in vitro, when administered with either gold (average diameter, 2 nm and 13 nm) or iron (average diameter, 14 nm) nanoparticles, increased with MNP solution concentration over the range of 0.1-2 mg/mL. With irradiation by 45-MeV proton therapy (PT) beam, higher concentrations had a decreased cell survival fraction. An in vivo study with tumor regression assay demonstrated significant tumor dose enhancement, thought to be result of the PIXE effect when compared to conventional PT without MNP using a 45 MeV proton beam (p<0.01). These effects were observed for gold and iron MNP, injected in doses of 100-300mg/kg body weight into CT-26 mouse tumor models via tail vein. A therapeutic effective MNP concentration range, in vivo,was estimated at 30-79 μg/g tissue for both gold and iron nanoparticles. The tumor dose enhancement may compensate for an increase in entrance dose associated with conventional PT when treating large, solid tumors with a spread out Bragg peak (SOBP) technique. The use of combined high energy Bragg peak PT with PIXE generated by MNP, or PIXE alone may result in new treatment options for infiltrative metastatic tumors and other diffuse inflammatory diseases

  16. New approaches for investigating paintings by ion beam techniques

    International Nuclear Information System (INIS)

    Beck, L.; Viguerie, L. de; Walter, Ph.; Pichon, L.; Gutierrez, P.C.; Salomon, J.; Menu, M.; Sorieul, S.

    2010-01-01

    Up to now, among the IBA techniques, only PIXE has been used for analyzing paintings. However, quantitative PIXE analysis is sometimes difficult to interpret due to the layered structure, the presence of varnish and organic binder and, in some cases, discoloration of the pigments has been observed due to the interaction of the ion beam with the compounds. In order to improve the characterization of paintings, we propose some alternative experimental procedures. First of all, backscattering spectrometry (BS) and PIXE are simultaneously combined in order to collect complementary information such as layer thickness and organic compound quantification. The simultaneous PIXE and BS experiments also have the advantage of being able to analyze the same area in one experiment. This combination, implemented with an external beam, was directly applied on paintings and on painting cross-sections for the study of Italian Renaissance masterpieces. We have obtained valuable results not only on the pigment itself but also, for the first time, on the binder to pigment proportion which is not well documented in the ancient recipes. Moreover, in order to restrain beam damages due to the ion stopping power, we propose to analyze very thin painting cross-sections by a combination of PIXE-RBS and Scanning Transmission Ion Microscopy (STIM).

  17. New approaches for investigating paintings by ion beam techniques

    Science.gov (United States)

    Beck, L.; de Viguerie, L.; Walter, Ph.; Pichon, L.; Gutiérrez, P. C.; Salomon, J.; Menu, M.; Sorieul, S.

    2010-06-01

    Up to now, among the IBA techniques, only PIXE has been used for analyzing paintings. However, quantitative PIXE analysis is sometimes difficult to interpret due to the layered structure, the presence of varnish and organic binder and, in some cases, discoloration of the pigments has been observed due to the interaction of the ion beam with the compounds. In order to improve the characterization of paintings, we propose some alternative experimental procedures. First of all, backscattering spectrometry (BS) and PIXE are simultaneously combined in order to collect complementary information such as layer thickness and organic compound quantification. The simultaneous PIXE and BS experiments also have the advantage of being able to analyze the same area in one experiment. This combination, implemented with an external beam, was directly applied on paintings and on painting cross-sections for the study of Italian Renaissance masterpieces. We have obtained valuable results not only on the pigment itself but also, for the first time, on the binder to pigment proportion which is not well documented in the ancient recipes. Moreover, in order to restrain beam damages due to the ion stopping power, we propose to analyze very thin painting cross-sections by a combination of PIXE-RBS and Scanning Transmission Ion Microscopy (STIM).

  18. New approaches for investigating paintings by ion beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Beck, L., E-mail: Lucile.beck@cea.f [Centre de Recherche et de Restauration des Musees de France (C2RMF), CNRS-UMR 171, Palais du Louvre - Porte des Lions, 14 quai Francois Mitterrand, 75001 Paris (France); Viguerie, L. de; Walter, Ph.; Pichon, L. [Centre de Recherche et de Restauration des Musees de France (C2RMF), CNRS-UMR 171, Palais du Louvre - Porte des Lions, 14 quai Francois Mitterrand, 75001 Paris (France); Gutierrez, P.C. [Centro de Micro-Analisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, E-28049 Madrid (Spain); Salomon, J.; Menu, M. [Centre de Recherche et de Restauration des Musees de France (C2RMF), CNRS-UMR 171, Palais du Louvre - Porte des Lions, 14 quai Francois Mitterrand, 75001 Paris (France); Sorieul, S. [Centre d' Etudes Nucleaires de Bordeaux-Gradignan, IN2P3, UMR 5797, Universite de Bordeaux 1, Chemin du Solarium BP120, 33175 Gradignan Cedex (France)

    2010-06-15

    Up to now, among the IBA techniques, only PIXE has been used for analyzing paintings. However, quantitative PIXE analysis is sometimes difficult to interpret due to the layered structure, the presence of varnish and organic binder and, in some cases, discoloration of the pigments has been observed due to the interaction of the ion beam with the compounds. In order to improve the characterization of paintings, we propose some alternative experimental procedures. First of all, backscattering spectrometry (BS) and PIXE are simultaneously combined in order to collect complementary information such as layer thickness and organic compound quantification. The simultaneous PIXE and BS experiments also have the advantage of being able to analyze the same area in one experiment. This combination, implemented with an external beam, was directly applied on paintings and on painting cross-sections for the study of Italian Renaissance masterpieces. We have obtained valuable results not only on the pigment itself but also, for the first time, on the binder to pigment proportion which is not well documented in the ancient recipes. Moreover, in order to restrain beam damages due to the ion stopping power, we propose to analyze very thin painting cross-sections by a combination of PIXE-RBS and Scanning Transmission Ion Microscopy (STIM).

  19. ERDA with an external helium ion micro-beam: Advantages and potential applications

    International Nuclear Information System (INIS)

    Calligaro, T.; Castaing, J.; Dran, J.-C.; Moignard, B.; Pivin, J.-C.; Prasad, G.V.R.; Salomon, J.; Walter, P.

    2001-01-01

    Preliminary ERDA experiments at atmospheric pressure have been performed with our external microprobe set-up currently used for the analysis of museum objects by PIXE, RBS and NRA. The objective was to check the feasibility of hydrogen (and deuterium) profiling with an external beam of 3-MeV helium ions. The standard scattering geometry (incident beam at 15 deg. with respect to sample surface and emerging protons or deuterons at 15 deg. in the forward direction) was kept, but the thin foil absorber was replaced by helium gas filling the space between the beam spot and the detector over a distance of about 84 mm. Several standards prepared by ion implantation, with well known H or D depth profiles, were first analysed, which indicated that the analytical capability was as good as under vacuum. A striking feature is the much lower surface peak than under vacuum, a fact that enhances the sensitivity for H analysis near the surface. The same type of measurement was then performed on different materials to show the usefulness of the technique. As a first example, we have checked that the incorporation of H or D into sapphire crystals during mechanical polishing is below the detection limit. Another example is the measurement of the H content in emeralds which can be used as an additional compositional criterion for determining the provenance of emeralds set in museum jewels. The advantages and limitations of our set-up are discussed and several possible applications in the field of cultural heritage are described

  20. PIXE analysis of historical paintings: Is the gain worth the risk?

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France); Gonzalez, V. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Pichon, L. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm{sup 2} or μC/cm{sup 2}. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm{sup 2}) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using

  1. PIXE analysis of historical paintings: Is the gain worth the risk?

    International Nuclear Information System (INIS)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-01-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm"2 or μC/cm"2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm"2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory

  2. PIXE analysis of historical paintings: Is the gain worth the risk?

    Science.gov (United States)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-11-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm2 or μC/cm2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1-300 μC/cm2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory-based scanning

  3. Development of a sample chamber for micro-PIXE

    International Nuclear Information System (INIS)

    Kurosawa, M.; Sueno, S.; Shima, K.; Ohshima, H.; Ishii, H.; Kamiya, H.; Kimoto, S.

    1997-01-01

    A new sample chamber for micro-PIXE analysis of geological thick samples has been successfully developed. A target in the sample chamber is normal to the beam and Si(Li) detectors are located at 135deg to the beam direction. For the sample observation, a normal viewing optics with the optical axis collinear with the beam is achieved by a combination of long working distance microscope and mirror with a central hole for the beam transmission. The normal incidence beam and normal viewing are essential to raise a spatial resolution of the thick target analysis. In addition, the sample chamber has fulfilled ten requirements as for material, driving stage, X-ray absorbers, space for another detector, etc. The information obtained by the development can give a new guide to manufacture the sample chamber for the micro-PIXE. (author)

  4. Application of micro beam PIXE to detection of titanium ion release from dental and orthopaedic implants

    International Nuclear Information System (INIS)

    Ektessabi, A.M.; Otsuka, T.; Tsuboi, Y.; Yokoyama, K.; Albrektsson, T.; Sennerby, L.; Johansson, C.

    1994-01-01

    In the past two decades the utilization of dental and orthopaedic implants in reconstructive surgery has been spread widely. Most of these implants are inserted in the corrosive environment of the human body for long periods of time. The level of dissolution, release, and transport of metal ions as a result of corrosion of these materials are not fully known at present. We report the results of application of micro ion beam PIXE spectroscopy to detect release of titanium from titanium and titanium alloy implants inserted in the tibiae of rabbits for three months. It was found that titanium ions could be detected in the surrounding tissues, with high precision, as a gradient from the implant surface and in higher amounts in the bone tissue as compared with the soft tissues. It is concluded that application of micro ion beam PIXE spectroscopy for detection of metal ion release, and distribution of the released material around the implants with high special resolution and accuracy may be used to further investigate the mechanism of metal release, and the relation between surface micromorphology and corrosion resistance of the implant materials. (author)

  5. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Energy Technology Data Exchange (ETDEWEB)

    Migliori, A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)], E-mail: migliori@fi.infn.it; Grassi, N.; Mando, P.A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)

    2008-05-15

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 {mu}m size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  6. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    International Nuclear Information System (INIS)

    Migliori, A.; Grassi, N.; Mando, P.A.

    2008-01-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness

  7. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Science.gov (United States)

    Migliori, A.; Grassi, N.; Mandò, P. A.

    2008-05-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  8. Elemental analysis of hair using PIXE-tomography and INAA

    International Nuclear Information System (INIS)

    Beasley, D.; Gomez-Morilla, I.; Spyrou, N.

    2008-01-01

    3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey. (author)

  9. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  10. Analysis of iron gall inks by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Budnar, Milos [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia)]. E-mail: milos.budnar@ijs.si; Ursic, Mitja [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Simcic, Jure [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Pelicon, Primoz [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Kolar, Jana [National University Library, Turjaska 1, SI-1000 Ljubljana (Slovenia); Selih, Vid Simon [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia); Strlic, Matija [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia)

    2006-02-15

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents.

  11. Analysis of iron gall inks by PIXE

    International Nuclear Information System (INIS)

    Budnar, Milos; Ursic, Mitja; Simcic, Jure; Pelicon, Primoz; Kolar, Jana; Selih, Vid Simon; Strlic, Matija

    2006-01-01

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents

  12. CdTe detector based PIXE mapping of geological samples

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, P.C., E-mail: cchaves@ctn.ist.utl.pt [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Taborda, A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Oliveira, D.P.S. de [Laboratório Nacional de Energia e Geologia (LNEG), Apartado 7586, 2611-901 Alfragide (Portugal); Reis, M.A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal)

    2014-01-01

    A sample collected from a borehole drilled approximately 10 km ESE of Bragança, Trás-os-Montes, was analysed by standard and high energy PIXE at both CTN (previous ITN) PIXE setups. The sample is a fine-grained metapyroxenite grading to coarse-grained in the base with disseminated sulphides and fine veinlets of pyrrhotite and pyrite. Matrix composition was obtained at the standard PIXE setup using a 1.25 MeV H{sup +} beam at three different spots. Medium and high Z elemental concentrations were then determined using the DT2fit and DT2simul codes (Reis et al., 2008, 2013 [1,2]), on the spectra obtained in the High Resolution and High Energy (HRHE)-PIXE setup (Chaves et al., 2013 [3]) by irradiation of the sample with a 3.8 MeV proton beam provided by the CTN 3 MV Tandetron accelerator. In this paper we present results, discuss detection limits of the method and the added value of the use of the CdTe detector in this context.

  13. Study of Italian Renaissance sculptures using an external beam nuclear microprobe

    Science.gov (United States)

    Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J. R.

    2000-03-01

    The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented.

  14. Study of Italian Renaissance sculptures using an external beam nuclear microprobe

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J.R.

    2000-01-01

    The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented

  15. External Beam Radiation Therapy for Cancer

    Science.gov (United States)

    External beam radiation therapy is used to treat many types of cancer. it is a local treatment, where a machine aims radiation at your cancer. Learn more about different types of external beam radiation therapy, and what to expect if you're receiving treatment.

  16. A PIXE mini-beam setup at the Bonn cyclotron for archeometric metal analyses

    International Nuclear Information System (INIS)

    Weber, J.; Beier, T.; Diehl, U.; Lambrecht, D.; Mommsen, H.; Pantenburg, F.J.

    1990-01-01

    The exact analysis of the elemental composition at and around a soldering joint of an antique piece of jewelry can elucidate the joining technologies and give hints of the genuineness of the object. As analytical method we use PIXE, which is nondestructive, multielemental and with fundamental parameter calculations gives absolute concentration values. To obtain the necessary spot size of the H 2 + beam at the Bonn cyclotron we use a piezo-controlled diaphragm, whose demagnified image is focussed on the target by two magnetic quadrupole triplets. With an electrostatic deflector the beam spot of 0.1x0.3 mm 2 size can be moved 2 mm in each direction on the target. With a laser beam, which simulates the ion beam, an irregularly shaped archeological object can be positioned. The laser is also used to obtain the alignment of the target surface to the ion beam direction and the small beam size makes it easier to find a flat part on the surface of the object; both of these are important preconditions for using the fundamental parameter method. A scan over a joint of modern gold alloys demonstrates the ability to detect soldering joints. The analysis of four pieces of Roman gold jewelry found in the area of Cologne and Bonn shows examples of brazing with a solder as well as diffusion soldering. (orig.)

  17. Setting up of a PIXE facility at FOTIA at BARC

    International Nuclear Information System (INIS)

    Joseph, Daisy; Saxena, A.

    2005-01-01

    PIXE-(Proton Induced X-ray Emission) -an ideal technique for material characterization has been set up at the Folded Tandem Ion Accelerator (FOTIA) at BARC, Trombay. A separate beam line at 45 deg port in which a dedicated PIXE chamber has been installed is being used for PIXE studies. PIXE studies on gold standards were carried out using protons of energy 3.3 MeV. Caritage values of gold standards were obtained which agree well with the certified values. Single element standard solutions (100 μg/ml) for low-Z elements such as Cr, Mn, Fe, Co, Cu and Zn were analyzed by PIXE. Well resolved α and β components of the x-rays were seen with detection limits in the range of 0.8-4 μg/g. (author)

  18. PIXE characterization of Western Mediterranean and Anatolian obsidians and Neolithic provenance studies

    International Nuclear Information System (INIS)

    Le Bourdonnec, F.-X.; Delerue, S.; Dubernet, S.; Moretto, Ph.; Calligaro, Th.; Dran, J.-C.; Poupeau, G.

    2005-01-01

    The possibility of non-destructive elemental analysis makes PIXE a very attractive technique in archaeological provenance studies. This technique has been fruitfully implemented on two different facilities to address the issue of obsidian provenance in the Mediterranean and in surrounding regions. At C2RMF, we took advantage of the possibility to analyze large archaeological pieces with the external micro-beam set-up. At CENBG, we used the nuclear microprobe providing a 5 μm beam diameter in large scans (700 x 700 μm 2 ) to control the homogeneity of elemental distribution. In both cases we dosed the same set of 13 elements: Na, Al, Si, K, Ca, Ti, Mn, Fe, Zn, Ga, Rb, Sr and Zr. While at C2RMF, two Si(Li) detectors were used simultaneously to measure all elements at once with 3 MeV protons, at CENBG where only one detector was available, the light elements Na to Fe were determined with a 1.5 MeV beam, and the heavy ones, including Fe, with a beam energy of 2.7 MeV. In Western Mediterranean, it is possible with PIXE to differentiate all obsidian sources of archaeological significance. Examples are given of obsidian provenances from Neolithic sites of France and from the islands of Corsica and Sardinia. In the Near East, we can differentiate the Cappadocian and Eastern Anatolian obsidian sources used during the early Neolithic. This is illustrated by examples taken from Neolithic sites of the Middle Euphrates Valley (Syria)

  19. Development of a PIXE (Particle Induced X-ray Emission) analysis device using an extracted proton beam

    International Nuclear Information System (INIS)

    Saidi, A.

    1989-01-01

    The experimental device described allows the extention of the PIXE (Particle Induced X-ray Emission) method to the analysis, by means of proton beams, of solid or liquid samples, which can not be analyzed under vacuum conditions. The homogeneity of the surfaces to be analysed and elements (in the atmosphere) which absorb X-rays must be taken into account. Liquid samples do not need special care. The results show that: at high energies, the extracted beam sensibility is of the same order of magnitude as those obtained under vacuum; at low energies, the performance under vacuum conditions is better. The particles energy losses, at the exit membrane and in the outer atmosphere, decrease the X-rays production efficiency [fr

  20. Calibration of PIXE-SP system of elementary analysis

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1983-04-01

    The set-up and calibration of the PIXE-SP System of Elementary Analysis located at the Institute of Physics of the University of Sao Paulo is described. The PIXE-SP, that operates with 8 MeV alpha beam, has been calibrated for elements with Z >= 11, by means of homemade evaporated standard targets of Al, Si, Bacl 2 , K 2 CrO 4 , Ti, Cr, Mn, Fe, Cu, Ge, Ag, Sn, and Au. Those targets are thin, homogeneous, and have been calbrated on a microbalance within an average precision of 6%. The overall precision of the PIXE-SP System is estimated in 10% for elements with 16 2 thick, irradiated with a 10 μC electric charge, shows a minimum of about 0,1 ng (approximated 4 ppm) for Mn. The PIXE-SP System has also been intercalibrated with the PIXE located at University of Gent, Belgium, by means of 12 atmospheric aerosol targets collected on two Batelle Cascade Impactors. The analyzed masses of elements with 16 [pt

  1. Analysis of kidney stones by PIXE and RBS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Alkofai, M M [Physics Dept., Yarmouk University, Irbid, (Jordan); Hallak, A B [Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, (Saudi Arabia)

    1995-10-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He{sup ++} beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab.

  2. Analysis of kidney stones by PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Alkofai, M.M.; Hallak, A.B.

    1995-01-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He ++ beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab

  3. PIXE measurements of Renaissance silverpoint drawings at VERA

    Energy Technology Data Exchange (ETDEWEB)

    Milota, Petra [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Reiche, Ina; Duval, Alain [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Forstner, Oliver [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Guicharnaud, Helene [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Kutschera, Walter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Merchel, Silke [Centre Europeen de Recherche et d' Enseignement des Geosciences de l' Environnement (CEREGE), CNRS UMR 6635, F-13545 Aix en Provence (France); Priller, Alfred [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Schreiner, Manfred [Institute of Science and Technology in Art, Academy of Fine Arts Vienna, A-1010 Vienna (Austria); Steier, Peter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Thobois, Elisabeth [Albertina, Albertinaplatz 1, A-1010 Vienna (Austria); Wallner, Anton; Wuenschek, Barbara [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Golser, Robin [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria)], E-mail: robin.golser@univie.ac.at

    2008-05-15

    Silverpoint drawings from the Renaissance are among the most precious and rarest treasures of graphical art. Our research group is particularly interested in the analysis of silverpoint drawings by Albrecht Duerer (1471-1528). A very sensitive and non-destructive analytical method, either spatially resolved synchrotron-radiation induced X-ray fluorescence (SY-XRF) or proton-induced X-ray emission (PIXE), is needed to determine the chemical composition of the very faint silver marks on such drawings. Duerer drawings from the collection of the Albertina, Vienna, were analyzed to amend existing data on Duerer drawings. For this purpose an external-beam PIXE setup was installed at the Vienna Environmental Research Accelerator (VERA). It allows to analyze a spot of {approx}0.15 mm on the object in air with 3 MeV protons, and to detect the emitted X-rays that are characteristic for the chemical composition with very good sensitivity and without harming the precious objects. After successful measurements on artificial test samples, four original silverpoint drawings were investigated: two portraits from Albrecht Duerer's very early period (self-portrait and portrait of his father) and two drawings from Duerer's sketch book of his travel to the Netherlands 1520/21.

  4. Beam-beam effects under the influence of external noise

    International Nuclear Information System (INIS)

    Ohmi, K

    2014-01-01

    Fast external noise, which gives fluctuation into the beam orbit, is discussed in connection with beam-beam effects. Phase noise from crab cavities and detection devices (position monitor) and kicker noise from the bunch by bunch feedback system are the sources. Beam-beam collisions with fast orbit fluctuations with turn by turn or multi-turn correlations, cause emittance growth and luminosity degradation. We discuss the tolerance of the noise amplitude for LHC and HL-LHC

  5. Application of micro-PIXE and imaging technology to life science (Joint research)

    International Nuclear Information System (INIS)

    Satoh, Takahiro; Ishii, Keizo

    2011-03-01

    The joint research on 'Application of micro-PIXE and imaging technology to life science' supported by the Inter-organizational Atomic Energy Research Program, had been performed for three years, from 2006FY to 2009FY. Aiming to apply in-air micro-PIXE analytical system to life science, the research was consisting of 7 collaborative themes related to beam engineering for micro-PIXE and applied technology of element mapping in biological/medical fields. The system, so-called micro-PIXE camera, to acquire spatial element mapping in living cells was originally developed by collaborative research between the JAEA and the department of engineering of Tohoku University. This review covers these research results. (author)

  6. Corrosion of 15th and early 16th century stained glass from the monastery of Batalha studied with external ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Vilarigues, M., E-mail: mgv@fct.unl.pt [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Redol, P. [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Monastery of Batalha, P-2440 (Portugal); Machado, A. [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Rodrigues, P.A.; Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2011-02-15

    This paper reports the study of corrosion in two stained glass panels from the south aisle of Sta. Maria da Vitoria monastery, at Batalha (Portugal), one depicting the Last Supper (dated from 1508), and the other one showing a saint (c. 1450). These panels exhibit extensive corrosion with darkening phenomena that are an impediment to their correct visualization, a source of major concern both to conservators and curators. By using external micro-beam Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma Emission (PIGE) spectrometry, the elemental compositions of large fragments were obtained, enabling the selection of representative corroded areas, from which elemental distribution maps were produced by scanning. Calcium and potassium rich structures were found - at the surface and inside cavities in the glass - that were identified as oxalates and carbonates, by Raman microscopy and micro-FTIR. The dark spots present in the glass surfaces were found to be Zn and Pb rich. These findings indicate that the corrosion observed was due not only to reactions with atmospheric water and CO{sub 2} but also with the oxalic acid secreted by micro-organisms. Furthermore, it did not result from reactions with atmospheric SO{sub 2} or acid rain. The information obtained is relevant for a better understanding of the corrosion processes and products formed on the surface of these panels and therefore for the proper planning of much needed adequate conservation-restoration actions and appropriate display conditions. - Research Highlights: {yields} Corrosion and darkening of stained glasses is of concern to conservators and curators. {yields} A multi-technique approach is of relevance to study stained glass corrosion. {yields} External beam PIXE-PIGE provide valuable insight on stained glass corrosion.

  7. Particle Induced X-ray Emission (PIXE) Approach for the Quantification of Thin Al Films

    International Nuclear Information System (INIS)

    Younes, G; Zahraman, K; Nsouli, B; Soueidan, M; Ferro, G

    2008-01-01

    Particle Induced X-ray Emission (PIXE) has been used as a fast and non-destructive technique for sensitive characterization of ultra thin Al films deposited by evaporation onto Si substrate. In this work the PIXE technique was optimized, using proton beam at different energies and different angles of incidence, for the characterization of ultra thin Al films (few nanometers) deposited onto Si substrate. The PIXE results showed that a proton beam of 300 keV under tilting angle of 80 degree permits an accurate determination of Al with high sensitivity within few minutes of acquisition time and a LOD of less than 0.2 nm. The LOD versus energy and tilting angle will be presented and discussed. (author)

  8. The use of macro and micro proton beams to study the variation in PIXE yield from metal targets insulated with PTFE, glass and nylon

    International Nuclear Information System (INIS)

    Pillay, A.E.

    1999-01-01

    Proton beams of diameters of 3 mm and 3 μm, were used to observe the differences in PIXE yield from pure metal targets encapsulated with PTFE, glass (macor) and nylon. The beam energy was kept constant at 700 keV. Beam currents varied from about 200 pA with the microbeam and between 1-10 nA with the macrobeam. Considerable enhancement was observed mainly with the use of PTFE, up to about a factor of 18 with the macrobeam and 306 with the microbeam. (author)

  9. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  10. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  11. PIXE and PGAA - Complementary methods for studies on ancient glass artefacts (from Byzantine, late medieval to modern Murano glass)

    Science.gov (United States)

    Constantinescu, Bogdan; Cristea-Stan, Daniela; Szőkefalvi-Nagy, Zoltán; Kovács, Imre; Harsányi, Ildikó; Kasztovszky, Zsolt

    2018-02-01

    Combined external milli-beam Particle Induced X-ray Emission (PIXE) and Prompt Gamma Activation Analysis (PGAA) analysis was applied to characterize the composition of paste and colorants from some fragments of Byzantine bracelets (10th-12th Centuries AD), late medieval (17th-18th Centuries AD) and modern Murano glass pieces. As fluxes, PGAA revealed the samples are soda-lime glass, except four samples - two medieval vessel white shards and two dark Byzantine fragments of bracelets - which have potash flux. Aluminium was detected in various proportions in all samples indicating different sources for the added sand. The presence of Magnesium is relevant only in one bracelet fragment suggesting the use of plant (wood?) ash and confirming that the Byzantine bracelet is manufactured from the mixture of both types of glass (natron and plant ash based). PGAA also indicated the presence of low quantities of Cadmium, high level of Arsenic and Lead (possibly lead arsenate) in one medieval sample and of ZnO in Murano glass, and of CoO traces (maximum 0.1%) in all blue-colored Byzantine, late medieval to modern Murano glass artefacts. PIXE confirmed the use of small quantities of CoO for blue color, indicated Manganese combined with Iron for dark glass, Copper for green, Lead, Tin and an Arsenic compound (orpiment?) for yellow and in the case of modern Murano glass Selenium and Cadmium to obtain a reddish color. Despite PIXE - PIGE combination is probably the best one for glass analysis, our external milli-PIXE - PGAA methods proved to be adequate complementary tools to determine many chemical elements from glass composition - Si, Na, K, Ca, Al, Mg, various metallic oxides.

  12. Study of ancient Islamic gilded pieces combining PIXE-RBS on external microprobe with sem images

    International Nuclear Information System (INIS)

    Ynsa, M.D.; Gutierrez, P.C.; Enguita, O.; Chamon, J.; Pardo, A.I.; Arroyo, M.; Barrio, J.; Gomez-Morilla, I.; Ferretti, M.; Climent-Font, A.

    2008-01-01

    Numerous metallic objects with very aesthetic and technological qualities have been recovered by archaeological excavations. Adequate processes of restoration and conservation treatments require the accurate determination of the elemental composition and distribution within the objects, as well as the identification of the nature and distribution of the corrosion products. Ideally the identification method should cause no alteration in the sample. In this work, different archaeological pieces with a gilded look have been characterized using simultaneously PIXE and RBS at the CMAM external microprobe in order to study the gilding metalworking done in the Iberian Peninsula during the Middle Ages. The gold layer thickness and its elemental concentrations of Ag, Au and Hg were determined by both techniques and compared with the scanning electron microscopy images obtained for some fragments of pieces. (orig.)

  13. External-PIXE identification of material for popular music pipes during the late Meiji era, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Tokimitsu; Yoshie; Maeda, Kuniko; Murao, Satoshi; Henseler, Ewald

    1998-07-01

    Two types of music pipes, Ginteki and Suifukin, that were popular during the late Meiji period in Japan were semi-quantitatively analyzed by the external-PIXE at RIKEN. The aim of this study is to identify the material used for these pipes and to assist the description to make an instrumental catalogue. Our results show that most of the collected Ginteki, literally silver flute, is composed of two parts. One is the whistle head of Pb-Sb alloy with the Pb to Sb ratio between 5.9 and 6.4; and the other is the main body with six holes which is made of tinplate. All of the Ginteki in this study are nickel coated. The Suifukin, on the contrary, is made of only tinplate and is not coated with nickel. (author)

  14. External-PIXE identification of material for popular music pipes during the late Meiji era, Japan

    International Nuclear Information System (INIS)

    Tokimitsu; Yoshie; Maeda, Kuniko; Murao, Satoshi; Henseler, Ewald

    1998-01-01

    Two types of music pipes, Ginteki and Suifukin, that were popular during the late Meiji period in Japan were semi-quantitatively analyzed by the external-PIXE at RIKEN. The aim of this study is to identify the material used for these pipes and to assist the description to make an instrumental catalogue. Our results show that most of the collected Ginteki, literally silver flute, is composed of two parts. One is the whistle head of Pb-Sb alloy with the Pb to Sb ratio between 5.9 and 6.4; and the other is the main body with six holes which is made of tinplate. All of the Ginteki in this study are nickel coated. The Suifukin, on the contrary, is made of only tinplate and is not coated with nickel. (author)

  15. In-vivo elemental imaging of plants using in-air submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, Shigeo; Ishii, Keizo; Kikuchi, Yohei; Kawamura, Yu; Yamazaki, Hiromichi; Watanabe, Ryohei; Tashiro, Kumiko; Inoue, Chihiro

    2008-01-01

    We developed a PIXE analysis system which provides spatial distribution images of elements in a region of 3x3 cm 2 with a spatial resolution of ∼0.5 mm. We call this system a submilli-PIXE camera. For in-vivo imaging of plants, we combined the submilli-PIXE camera with an in-air analysis. The high-speed beam scanning and the in-air analysis also reduce the risk of damaging the plants, thus in-vivo imaging could be realized. We applied the in-air submilli-PIXE camera to phytoremediation research. Phytoremediation is a technology for cleaning metal-contaminated soils using plant physiology. To study accumulation mechanisms for heavy metals, elemental distribution in plant organ should be known as well as average concentration. Elemental images of fronds were obtained in-vivo without sample preparation. Elemental map of the fronds showed that arsenic was accumulated in the edges of Pteris vittata fronds. The in-air submilli-PIXE camera clearly shows the accumulation of arsenic in fronds. The in-air submilli-PIXE camera is an effective tool for undertaking phytoremediation research. (author)

  16. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  17. Radiation damage of paper samples in in-air PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T.; Orihara, H.

    1999-01-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  18. Radiation damage of paper samples in in-air PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T. [Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi (Japan); Orihara, H. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center

    1999-07-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  19. Pre-Hispanic ceramics analyzed using PIXE and radiographic techniques

    International Nuclear Information System (INIS)

    Lima, S.C.; Rizzutto, M.A.; Added, N.; Barbosa, M.D.L.; Trindade, G.F.; Fleming, M.I.D.A.

    2011-01-01

    Ceramics objects are the most common artifacts found during excavation of archaeological sites and often depicts cultural habits and manufacturing technologies of the culture. The determination of macroscopic and microscopic characteristics of the ceramic objects such as the ceramic porosity, addition of tempers in the clay, main chemical components and the trace elements present in the ceramic can reveal many aspects about the manufacturing processes used by the culture, its degree of development, the provenance of the raw materials and the exchange networks. Also the radiography can help to investigate the manufactured processes, the size of the tempers used and the conservation status of the artifacts. In this present work two non-destructive techniques, radiography and PIXE (Particle Induced X-ray Emission) were used to characterize one set of thirty-six pre-Hispanic ceramic pieces from the Chimu Culture conserved in the Museu de Arqueologia e Etnologia (MAE/USP). The PIXE analyses performed in the external beam setup at LAMFI (Laboratório de Análise de Materiais por Feixes Iônicos) allowed measure the principal chemical elements such as Al, Si, K, Ti, Fe and Ca, present in this group of pieces. X-ray imagings allowed identify the manufacture processes, the granularity of the tempers used, as well as the similarity and the differences between the pieces studied.

  20. CONTINOUS EXTRACTED BEAM IN THE AGS FAST EXTERNAL BEAM LINE

    International Nuclear Information System (INIS)

    GLENN, J.W.; TSOUPAS, N.; BROWN, K.A.; BIRYUKOV, V.M.

    2001-01-01

    A method to split off a few percent of the 6 x 10 13 AGS beam delivered to the Slow External Beam (SEB) lines and send it down the Fast External Beam line (FEB) has been developed. The mission is to feed a counter experiment off the FEB that directly measures the neutrino mass using the muon storage ring. The use of normal thin septum splitters would have an excessive loss overhead and been optically difficult. The AGS Slow Extraction uses a third integer resonance with sextuple strength so the resonance width is a few percent of the beam width. This results in a low density tail which will be clipped by a bent crystal and deflected into the FEB channel. This clipping off of the tail should reduce losses in the SEB transport line. Details of modeled orbits, particle distribution and extraction trajectories into and out off the crystal will be given

  1. Comparative study between the PIXE technique and neutron activation analysis for Zinc determination

    International Nuclear Information System (INIS)

    Cruvinel, Paulo Estevao; Crestana, Silvio; Artaxo Netto, Paulo Eduardo

    1997-01-01

    This work presents a comparative study between the PIXE, proton beams and neutron activation analysis (NAA) techniques, for determination of total zinc concentration. Particularly, soil samples from the Pindorama, Instituto Agronomico de Campinas, Sao Paulo State, Brazil, experimental station have been analysed and measuring the zinc contents in μg/g. The results presented good correlation between the mentioned techniques. The PIXE and NAA analyses have been carried out by using the series S, 2.4 MeV proton beams Pelletron accelerator and the IPEN/CNEN-IEA-R1 reactor, both installed at the Sao Paulo - Brazil university

  2. Non-destructive study of ancient documents and books by means of ion beams

    International Nuclear Information System (INIS)

    Ruvalcaba S, J.L.; Monroy, M.

    2004-01-01

    In this work, a non destructive methodology for the analysis of ancient manuscripts and books using an external beam system and the techniques Particle Induced X-ray Emission Spectroscopy (PIXE) and Rutherford Backscattering Spectrometry (RBS) is presented. This application shows the analytical features of the particle accelerator based techniques for the characterization of this kind of historical materials. This methodology was used for the analysis of inks of an European book from XVII century. This is the first study in Mexico of an ancient book using simultaneously PIXE and RBS non-vacuum techniques. (Author) 21 refs., 9 figs

  3. Shear behavior of concrete beams externally prestressed with Parafil ropes

    Directory of Open Access Journals (Sweden)

    A.H. Ghallab

    2013-03-01

    Full Text Available Although extensive work has been carried out investigating the use of external prestressing system for flexural strengthening, a few studies regarding the shear behavior of externally prestressed beams can be found. Five beams, four of them were externally strengthened using Parafil rope, were loaded up to failure to investigate the effect of shear span/depth ratio, external prestressing force and concrete strength on their shear behavior. Test results showed that the shear span to depth ratio has a significant effect on both the shear strength and failure mode of the strengthened beams and the presence of external prestressing force increased the ultimate load of the tested beams by about 75%. Equations proposed by different codes for both the conventional reinforced concrete beams and for ordinary prestressed beams were used to evaluate the obtained experimental results. In general, codes equations showed a high level of conservatism in predicting the shear strength of the beams. Also, using the full strength rather than half of the concrete shear strength in the Egyptian code PC-method improves the accuracy of the calculated ultimate shear strength.

  4. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  5. PIXE investigation of Roman metal archaeological objects from the Municipium Tifernum Mataurense area (S. Angelo in Vado, Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Rogante, M., E-mail: main@roganteengineering.it [Rogante Engineering Office, Contrada San Michele n. 61, 62012 Civitanova Marche (Italy); Kovács, I. [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Konkoly Thege Str., 29-33, 1121 Budapest (Hungary); Rosta, L. [Institute for Solid State Physics and Optics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Konkoly Thege Str., 29-33, 1121 Budapest (Hungary); Stortoni, E. [University of Macerata, Department of Educational Sciences, Cultural Heritage and Tourism, Polo didattico “L.Bertelli”, P.le Bertelli n. 1, 62100 Macerata (Italy); Szőkefalvi-Nagy, Z. [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Konkoly Thege Str., 29-33, 1121 Budapest (Hungary)

    2015-11-15

    Six rather different bronze archaeological artefacts discovered over time in the Tifernum Mataurense area (S. Angelo in Vado, Marche Region, Italy) did not fit by visual inspection to the findings collected in nearby archaeological sites and they differ from each other, too. The primary goal of this work was to obtain data from the elemental composition of using a fast non-destructive quantitative analytical method. To do that the external milli-beam particle induced X-ray emission spectroscopy (external milli-beam PIXE) was chosen. Taking into account that not any invasive actions as burnishing, scratching or chemical treatment were allowed and the surface of the objects was rather corroded or patinated, the results obtained can be considered to be rather informative, only. Even these informative results, however, are useful to set up a classification of the objects according to the chemical composition and provide complementary near-surface composition information to the bulk data expected from cold neutron PGAA analyses to be performed.

  6. PIXE investigation of Roman metal archaeological objects from the Municipium Tifernum Mataurense area (S. Angelo in Vado, Italy)

    International Nuclear Information System (INIS)

    Rogante, M.; Kovács, I.; Rosta, L.; Stortoni, E.; Szőkefalvi-Nagy, Z.

    2015-01-01

    Six rather different bronze archaeological artefacts discovered over time in the Tifernum Mataurense area (S. Angelo in Vado, Marche Region, Italy) did not fit by visual inspection to the findings collected in nearby archaeological sites and they differ from each other, too. The primary goal of this work was to obtain data from the elemental composition of using a fast non-destructive quantitative analytical method. To do that the external milli-beam particle induced X-ray emission spectroscopy (external milli-beam PIXE) was chosen. Taking into account that not any invasive actions as burnishing, scratching or chemical treatment were allowed and the surface of the objects was rather corroded or patinated, the results obtained can be considered to be rather informative, only. Even these informative results, however, are useful to set up a classification of the objects according to the chemical composition and provide complementary near-surface composition information to the bulk data expected from cold neutron PGAA analyses to be performed.

  7. Beam intensity monitoring for the external proton beam at LAMPF

    International Nuclear Information System (INIS)

    Barrett, R.J.; Anderson, B.D.; Willard, H.B.; Anderson, A.N.; Jarmie, N.

    1975-07-01

    Three different intensity monitors were tested in the external proton beam at LAMPF, and together cover the entire range of beam currents available. A 800 kg Faraday cup was installed and used to measure the absolute intensity to better than 1 percent for beam currents up to several nanoamperes. A high gain ion chamber was used as part of the calibration procedure for the Faraday cup, and was found to be useful when monitoring very small beam intensities, being reliable down to the few picoampere level. A secondary emission monitor was also tested, calibrated, and found to be trustworthy only for beams of greater than 50 pA intensity. (auth)

  8. PIXE analyses of polished otoliths for identification of anadromous whitefish in the Baltic Sea

    International Nuclear Information System (INIS)

    Lill, Jan-Olof; Heimbrand, Yvette; Slotte, Joakim; Himberg, Mikael; Florin, Ann-Britt; Hägerstrand, Henry

    2015-01-01

    In this work we describe an application of particle-induced X-ray emission (PIXE) to the elemental analysis of polished otoliths of whitefish. Two spots on polished otoliths were irradiated; one spot in the core region of the otolith and another one close to the edge. The irradiations were performed in air with a collimated 0.5 mm proton beam. The ratio of the strontium concentrations in the two spots was used to distinguish between different ecotypes (river, sea, lake) of whitefish. Criteria on the ratios were suggested for identification of the whitefish forms. The results were compared to results of μ-beam PIXE scans as well as multi-point scans with the 0.5 mm proton beam. The measuring set-up and the results are discussed.

  9. PIXE analyses of polished otoliths for identification of anadromous whitefish in the Baltic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Lill, Jan-Olof, E-mail: jlill@abo.fi [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Turku (Finland); Heimbrand, Yvette [Institute of Coastal Research, Department of Aquatic Resources, Swedish University of Agricultural Sciences (Sweden); Slotte, Joakim [Physics, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland); Himberg, Mikael [Laboratory of Aquatic Pathobiology, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland); Florin, Ann-Britt [Institute of Coastal Research, Department of Aquatic Resources, Swedish University of Agricultural Sciences (Sweden); Hägerstrand, Henry [Laboratory of Aquatic Pathobiology, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland)

    2015-11-15

    In this work we describe an application of particle-induced X-ray emission (PIXE) to the elemental analysis of polished otoliths of whitefish. Two spots on polished otoliths were irradiated; one spot in the core region of the otolith and another one close to the edge. The irradiations were performed in air with a collimated 0.5 mm proton beam. The ratio of the strontium concentrations in the two spots was used to distinguish between different ecotypes (river, sea, lake) of whitefish. Criteria on the ratios were suggested for identification of the whitefish forms. The results were compared to results of μ-beam PIXE scans as well as multi-point scans with the 0.5 mm proton beam. The measuring set-up and the results are discussed.

  10. Fundamentals of PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    1997-01-01

    Elemental analysis based on the particle induced x-ray emission (PIXE) is a novel technique to analyze trace elements. It is a very simple method, its sensitivity is very high, multiple elements in a sample can be simultaneously analyzed and a few 10 μg of a sample is enough to be analyzed. Owing to these characteristics, the PIXE analysis is now used in many fields (e.g. biology, medicine, dentistry, environmental pollution, archaeology, culture assets etc.). Fundamentals of the PIXE analysis are described here: the production of characteristic x-rays and inner shell ionization by heavy charged particles, the continuous background in PIXE spectrum, quantitative formulae of the PIXE analysis, the detection limit of PIXE analysis, etc. (author)

  11. The potential of PIXE analytical work in water pollution

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, H.; Takahashi, Y.; Ishii, K. [Dept. of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi (JP)] [and others

    1999-07-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-{mu}m pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of {approx}24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  12. The potential of PIXE analytical work in water pollution

    International Nuclear Information System (INIS)

    Yamazaki, H.; Takahashi, Y.; Ishii, K.

    1999-01-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-μm pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of ∼24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  13. Characterization of human fingernail elements using PIXE technique

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Ajose, O.A.; Makinde, N.O.; Buoso, M.C.; Ceccato, D.; De Poli, M.; Moschini, G.

    2005-01-01

    PIXE technique was employed in the determination of the major, minor and trace elemental concentrations in finger-nails of 62 healthy young adults (30 females and 32 males), aged between 20 and 37 years. The elemental concentrations in the nails of the analyzed population provide good reference data set for further health studies. The PIXE measurements were carried out using 1.8 MeV collimated proton beam from the 2.5 MV AN-2000 Van de Graaff accelerator at INFN, LNL, Legnaro (Padova), Italy. The results show the presence of twenty elements. Their metabolic roles in humans are presented and discussed. The comparison of our results with those of other authors are also presented

  14. Laboratory of ion beam applications at ATOMKI

    International Nuclear Information System (INIS)

    Borbely-Kiss, I.; Huszank, R.; Kertesz, Zs.; Kiss, A.Z.; Koltay, E.; Rajta, I.; Simon, A.; Szabo, Gy.; Szikszai, Z.; Szilasi, S.Z.; Szoboszlai, Z.; Uzonyi, I.

    2008-01-01

    Introduction. The Laboratory of Ion Beam Applications of ATOMKI is devoted to applications of atomic and nuclear physics in the fields of environmental research, biomedicine, geology, materials and surface science (including ion beam induced damage investigations and proton beam lithography) and cultural heritage research. We perform our work in the frame of various projects and collaborations: EU, IAEA, R and D, OTKA, etc. Our laboratory provides service for external (national and international) and internal users and contributes to higher education, as well. The Laboratory is based on the home-made 5 MV Van de Graaff (VdG) electrostatic accelerator of the institute. The accelerator was put into operation in 1971 and in the beginning it supplied ion beams exclusively for nuclear physics. A few years later with the measurements of K-shell ionization cross sections the door became open also for basic atomic physics. In parallel with this basic study, the application of proton induced X-ray emission (PIXE) for the elemental analysis of biological (hair, erythrocyte and blood plasma) samples and atmospheric aerosols also started. The first paper on PIXE, a methodological one, was published in 1978. The experience gained on these applications and later on archaeology led to the construction of complex PIXE chambers, which were sold, together with the corresponding know-how, to institutions in China, Portugal, Bangladesh, Jordan, North Korea, Singapore, Cuba and Mexico through the International Atomic Energy Agency (IAEA). For the evaluation of PIXE spectra the laboratory has been continuously developing its own computer programme package. The first version of this continuous development was published in 1988. In the meantime a second IBA analysis method, the proton induced gamma ray emission (PIGE), was introduced in the laboratory and was applied simultaneously with PIXE. Application of deuteron induced gamma ray emission (DIGE) started more than a decade later. A

  15. Use of silicon drift detectors for the detection of medium-light elements in PIXE

    International Nuclear Information System (INIS)

    Alberti, R.; Bjeoumikhov, A.; Grassi, N.; Guazzoni, C.; Klatka, T.; Longoni, A.; Quattrone, A.

    2008-01-01

    In order to fully exploit in PIXE the superior performance of silicon drift detectors especially for the detection of low- and medium-energy X-rays, avoiding in particular the negative effects of backscattered particles, we developed a custom spectrometer based on a 10 mm 2 chip with a thermoelectric Peltier cooler and home-designed front-end electronics, coupled to a weakly focusing polycapillary lens. This paper briefly describes the detector + lens assembly and reports the results of first tests carried out at an external beam line of the LABEC laboratory in Florence. Excellent energy resolution is achieved under real operating conditions in a PIXE run (measured FWHM at 1 keV is 81 eV with a count-rate of 480 cps) and also the lineshapes are very good (FW1/10M over FWHM ratio is 2.1). As a whole, our preliminary tests gave encouraging results and also helped to point out some aspects which it is worthwhile to investigate further (e.g. how X-ray peak intensity ratios may be affected by inaccurate lens alignment), in order to profit fully from such a good performance of the spectrometer

  16. PIXE applications to the toxicological field

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L. [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Instituto de Fisica. Laboratorio de Implantacao Ionica; Andrade, V.M. [Universidade do Extremo Sul Catarinense, Criciuma, SC (Brazil). Laboratorio de Biologia Celular e Molecular; Amaral, L.; Silva, J. da [Universidade Luterana do Brasil, Canoas, RS (Brazil). Laboratorio de Toxicologia Generica

    2013-07-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  17. PIXE applications to the toxicological field

    International Nuclear Information System (INIS)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L.; Andrade, V.M.; Amaral, L.; Silva, J. da

    2013-01-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  18. PIXE analysis of cancer-afflicted human bladder

    Energy Technology Data Exchange (ETDEWEB)

    Raju, G.J. Naga; Sarita, P.; Kumar, M. Ravi [Department of Physics, Institute of Technology, GITAM University, Visakhapatnam (India); Reddy, S. Bhuloka [Swami Jnanananda Laboratories for Nuclear Research, Andhra University, Visakhapatnam (India)

    2013-07-01

    Full text: The proton induced x-ray emission (PIXE) technique was used for analysis of trace elements in small quantities of biological samples. Both the biological samples of normal and cancer-afflicted human bladder tissues were studied. The present experiment was performed using a 3 MV pelletron accelerator at the Institute of Physics in Bhubaneswar, India. A proton beam of 3 MeV energy was used to excite the samples. NIST SRM 1577b Bovine Liver Tissue was used as external standards for the determination of trace element concentration in the biological tissue samples. The elements CI, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, and Se were identified and their concentrations were estimated. The concentrations of Ti and Zn are lower (p < 0.005) and that of Cr, Mn, Fe, Ni, and Cu are significantly higher (p < 0.001) in cancerous tissues than that in normal tissues. The deficiency or excess of different trace elements observed in the cancer tissues relative to the normal tissues of bladder are correlated to the pathology of cancer. (author)

  19. Conventional external beam radiotherapy for central nervous system malignancies

    International Nuclear Information System (INIS)

    Halperin, E.C.; Burger, P.C.

    1985-01-01

    Fractionated external beam photon radiotherapy is an important component of the clinical management of malignant disease of the central nervous system. The practicing neurologist or neurosurgeon frequently relies on the consultative and treatment skills of a radiotherapist. This article provides a review for the nonradiotherapist of the place of conventional external beam radiotherapy in neuro-oncology. 23 references

  20. PIXE and ICP-AES comparison in evaluating the efficiency of metal extraction and analysis in aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Rugi, F.; Becagli, S.; Ghedini, C.; Marconi, M.; Severi, M.; Traversi, R.; Udisti, R. [Dep. of Chemistry, University of Florence, Sesto F.no (Fl) (Italy); Calzolai, G.; Chiari, M.; Lucarelli, F.; Nava, S. [Dep. of Physics and Astronomy , University of Florence and INFN, Sesto F. no (Fl) (Italy)

    2013-07-01

    Full text: A recent EU regulation (EN 149022005) requests the quantification of selected metals in the atmospheric particulate by mineralization with H{sub 2}0{sub 2} and HN0{sub 3} in microwave oven.This method might possibly conflict with the determination of the total metal content. In fact, the more the aerosol is enriched in crustal elements the more the difference in the two methods are expected, since the H{sub 2}0{sub 2}+ HN0{sub 3}, extraction is not reliable for metals in silicate form. In order to evaluate the extracted fraction, PIXE and ICP-AES measurements were carried out on the two halves of a series of PM10 and PM2.5 samples collected on Teflon filters in an urban site in the surrounding of Florence (Italy). An ICP-AES (Inductively Coupled Plasma -Atomic Emission Spectroscopy) method was optimized by an ultrasound nebuliser (CETAC 5000 AT+), in order to improve reproducibility and detection limit. In these conditions, it was possible quantifying AI, As, Cr, Cu, Fe, Mn, Ni, Pb and Vatsub-ppb levels. PIXE analysis using the external beam set-up at LABEC and a 3 MeV proton beam was carried out in order to measure the total elemental content of the metals. By comparing the ICP-AES and the PIXE results, a preliminary evaluation of the efficiency of the H{sub 2}0{sub 2} and HN0{sub 3} extraction method was performed. The obtained results (the mean values for the ICP-AES/PIXE ratio are reported in Table 1) show that the extraction procedure following the EN 14902 directive allows quantitative recoveries (80-120%, including the analytical uncertainties)for the majority of the analysed metals, especially for those mainly emitted by anthropic sources. This result points out that anthropic metals are present in the atmosphere as relatively available species (free metals, labile complexes, carbonates, oxides). On the contrary, lower recoveries were obtained for AI (mean value around 75%), a metal that has a relevant crustal fraction. Percentage of recovery of

  1. The bio-PIXE setup on the Debrecen scanning proton microprobe

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Szikszai, Z.; Uzonyi, I.; Simon, A.; Kiss, A.Z.

    2004-01-01

    Complete text of publication follows. Besides the ongoing applications in archeometry, geology, material science and atmospheric aerosol study, in recent years the IBA Group in Debrecen has joined several biological and biomedical research projects. Such studies require the knowledge of accurate quantitative elemental concentrations and distributions in organic, inhomogeneous thin samples on a microscopic scale. In most cases, to carry out quantitative investigations on biomedical samples down to the cell level, the combination of proton induced X-ray emission (PIXE), Rutherford backscattering (RBS) spectrometry and scanning transmission ion microscopy (STIM) analytical methods are used simultaneously. STIM provides information on the density and structure of the sample, PIXE measures the concentration of the inorganic major and trace elements, and finally RBS serves to characterize the organic matrix, to determine the beam dose, and sometimes the sample thickness. The drawback of this combined method is that to evaluate the RBS data the hydrogen to carbon ratio in the sample must be known. The setup developed at the Debrecen microprobe facility [1] is based on the combined application of on-axis STIM and simultaneous PIXE-PIXE analytical techniques. In the PIXE-PIXE method the sample matrix is determined directly by measuring X-rays from all elements in the sample including the light elements such as carbon and oxygen, using two Si(Li) X-ray detectors. In this arrangement an ultra thin windowed Si(Li) X-ray detector serves to characterize the matrix by measuring low energy X-ray lines (0.2-9 keV) while a large area Be-windowed detector is used to detect the medium and high energy X-ray lines (>4 keV). In this way elements with atomic number higher than 5 can be detected simultaneously, reducing both radiation damage of the sample and measurement time. In addition, the knowledge of the hydrogen content of the sample is not needed, since it influences the

  2. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F., E-mail: lucarelli@fi.infn.it; Calzolai, G.; Chiari, M.; Giannoni, M.; Mochi, D.; Nava, S.; Carraresi, L.

    2014-01-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN in Florence, an external beam facility is fully dedicated to measurements of elemental composition of atmospheric aerosol. The experimental set-up hitherto used for this kind of applications has been upgraded with the replacement of a traditional Si(Li) detector for the detection of medium–high Z elements with a silicon drift detector (SDD) with a big active area (80 mm{sup 2}) and 450 μm thickness, with the aim of obtaining better minimum detection limits (MDL) and reduce measuring times. The Upilex extraction window has been replaced by a more resistant one (Si{sub 3}N{sub 4}). A comparison between the old Si(Li) and the new SDD for aerosol samples collected on different substrata like Teflon, Kapton and Nuclepore evidenced the better performances of the SDD. It allows obtaining better results (higher counting statistics, lower MDLs) even in shorter measuring times, thus allowing very fast analysis of both daily and hourly samples.

  3. PIXE: early NAA revisited

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    A short, comparative evaluation of the methods of neutron activation analysis (NAA), and particle induced X-ray emission (PIXE), is given based on the Proc. of the 2nd international conference on PIXE and its analytical applications. The conference took place June 9-12, 1980, Lund, Sweden. 'The PIXE people have paralleled NAA people - in work, problems and mistakes, summarises the author, but PIXE was proved and established as a standard analytical method.' The method has proved extremely valuable in microprobe applications. (Sz.J.)

  4. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  5. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  6. Particle induced x-ray emission (PIXE) measurement of the Cd content in animal tissues

    International Nuclear Information System (INIS)

    Le Huong Quynh; Demeter, I.; Hollos-Nagy, K.; Szoekefalvi-Nagy, Z.

    1989-12-01

    Particle induced x-ray emission (PIXE) measurements were performed on thin samples prepared from different rabbit tissues, using 3 MeV proton beam for inducing x-rays from the animal tissues. This method is very sensitive and very small amounts of trace elements can be detected. Cadmium, one of the most toxic elements which can be concentrated in animal and human tissues due to environmental pollution, was detected with a limit of 0.7 ppm. The trace element concentrations obtained by PIXE were compared to those measured by atomic absorption spectrometry. PIXE method is proposed for routine analysis at the Veterinary and Food Investigating Service, Budapest, Hungary. (D.Gy.) 6 refs.; 3 figs

  7. Development of an external Faraday cup for beam current measurements

    International Nuclear Information System (INIS)

    Kim, Kye-Ryung; Jung, Myung-Hwan; Ra, Se-Jin; Lee, Seok-Ki

    2010-01-01

    In general, beam current measurements are very important for many kinds of experiments using highly energetic particle beams at accelerators, such as cyclotrons, linacs, etc. The Faraday cup is known to be one of the most popular beam current measurement tools. We developed an external Faraday cup to measure the beam current at a dedicated beam line for low-flux experiments installed at the MC-50 cyclotron of Korea Institute of Radiological and Medical Sciences (KIRAMS). It was designed for external beam current measurements and is composed of a vacuum chamber, an entrance window, a collimator, a electrostatic suppressor ring, and a cup. The window is made of 75-um-thick Kapton film, and the diameter of the collimator is 10 mm or 20 mm. The ring and the cup has 5-cm inner diameters, and the thickness of the bottom of the cup is 2 cm, which is enough to absorb the total proton energy up to 45 MeV. Using this external Faraday cup, we measured the beam current from the cyclotron, and we compared measured flux to the results from film dosimetry using GAF films.

  8. Comparison of radioimmunotherapy and external beam radiotherapy in colon cancer xenografts

    International Nuclear Information System (INIS)

    Buras, R.R.; Wong, J.F.C.; Kuhn, J.A.; Beatty, B.G.; Williams, L.E.; Beatty, J.D.; Wanek, P.M.

    1993-01-01

    Radioimmunotherapy and external beam radiotherapy were compared in a nude mouse human colon cancer model. Radioimmunotherapy was delivered by intraperitoneal injection of 90 Y-labeled anticarcinoembryonic antigen monoclonal antibody (anti-CEA MAB). Single fraction external beam radiotherapy was delivered using a 60 Co teletherapy unit. Control groups received saline, unlabeled anit-CEA monoclonal antibody and labeled nonspecific monoclonal antibody. Tumor growth suppression was expressed as delay to reach 2g compared to saline controls. Unlabeled anti-CEA monoclonal antibody and labeled nonspecific monoclonal antibody had no effect. External beam radiotherapy of 300, 600, 1000 and 2000 cGy produced growth delays of 3, 12, 17, and 22 days, respectively. Radioimmunotherapy with 120 μCi, 175 μCi, and 225 μCi resulted in growth delays of 20, 34, and 36 days. Estimated absorbed tumor dose was 1750 cGy in the 120 μCi group. Similar comparisons were done with the more radioresistant WiDr human colon carcinoma cell line. External beam radiotherapy doses of 400, 800, 1200, and 1600 cGy resulted in growth delays of 6, 21, 36 and 48 days, respectively. Radioimmunotherapy of 120 μCi and 175 μCi resulted in growth delays of 9 and 19 days, respectively. The 120 μCi dose delivered an estimated absorbed tumor dose of 1080 cGy to WiDr tumors. In summary, for the radiosensitive LS174T line, radioimmunotherapy produced biologic effects that were comparable to a similar dose of single fraction external beam radiotherapy. For the more radioresistant WiDr tumor, radioimmunotherapy produced a biologic effect which was less than a similar dose of single fraction external beam radiotherapy. These studies suggest that a tumor's response to radioimmunotherapy relative to that of external beam radiotherapy is, in part, dependent on tumor radiosensitivity and repair capacity. 23 refs., 5 figs. 4 tabs

  9. TXRF, PIXE, SYXRF; principles, critical comparison and applications

    International Nuclear Information System (INIS)

    Knoechel, A.

    1990-01-01

    At first glance X-Ray fluorescence analysis seems to be a very sensitive and effectful method to detect element traces in the multielement mode. But in praxi the application range is restricted, if X-Ray tubes are used as excitation sources. To overcome this situation, it is necessary to improve the conditions of excitation and to reduce the background, produced by different scattering effects. TXRF, PIXE and SYXRF, which allow multielement analysis in the trace- and ultratrace region are using this strategy. In the case of TXRF a remarkable background reduction is achieved if the sample is prepared as a thin amorphous film on a planar sample holder and the excitation beam of a X-Ray tube is totally reflected on its surface. In the case of PIXE a particle beam of high intensity is used as excitation source, improving the conditions of excitation and giving the opportunity of spatial resolved analyses. In the case of SYXRF the X-Ray fraction of synchrotron radiation is used as excitation source, giving the opportunity, to improve the conditions of excitation as well as to reduce the background by using the high polarisation of the beam. In this case, too, spatial resolved analysis are possible. The principles of the three methods are described, their advantages and disadvantages are critically compared and advanced applications from different analytical fields are presented. (orig.)

  10. PIXE analysis of Italian ink drawings of the XVI century

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Climent-Font, A.; Enguita, O.; Fernandez-Jimenez, M.T.; Finaldi, G.; Garrido, C.; Matillas, J.M.

    2005-01-01

    The composition of inks in a group of 24 drawings of ten XVI century Italian painters, has been determined by PIXE at the external micro-beam line of the Centro de Micro Analisis de Materiales of the Universidad Autonoma de Madrid. Ink elemental thicknesses have been determined by comparison with a set of certified thin standards. A comprehensive comparison of inks has also been performed by renormalisation of spectra and definition of an ink-to-ink distance. The elemental compositions and the ink-to-ink distances give consistent results that are generally in line with the appearance of the drawings and add relevant instrumental information to the stylistic observation, revealing for example the presence of retouches and additions in different parts of a drawing. Cluster analysis performed on a subgroup of 13 artefacts from the Genoese painter Luca Cambiaso and his school has revealed a partition that separates neatly the work of the master from that of his followers

  11. PIXE analysis of Italian ink drawings of the XVI century

    Science.gov (United States)

    Zucchiatti, A.; Climent-Font, A.; Enguita, O.; Fernandez-Jimenez, M. T.; Finaldi, G.; Garrido, C.; Matillas, J. M.

    2005-10-01

    The composition of inks in a group of 24 drawings of ten XVI century Italian painters, has been determined by PIXE at the external micro-beam line of the Centro de Micro Análisis de Materiales of the Universidad Autónoma de Madrid. Ink elemental thicknesses have been determined by comparison with a set of certified thin standards. A comprehensive comparison of inks has also been performed by renormalisation of spectra and definition of an ink-to-ink distance. The elemental compositions and the ink-to-ink distances give consistent results that are generally in line with the appearance of the drawings and add relevant instrumental information to the stylistic observation, revealing for example the presence of retouches and additions in different parts of a drawing. Cluster analysis performed on a subgroup of 13 artefacts from the Genoese painter Luca Cambiaso and his school has revealed a partition that separates neatly the work of the master from that of his followers.

  12. Enhanced identification of trace element fingerprint of prehistoric pigments by PIXE mapping

    Science.gov (United States)

    Lebon, M.; Pichon, L.; Beck, L.

    2018-02-01

    The elemental composition of Fe rich rocks used as pigment during prehistoric periods can provide valuable information about the type of material used and their geological origin. However, these materials present several analytical constraints since their patrimonial value involve using non-invasive techniques maintaining a high sensitivity of the detection and the quantification of trace elements. Micro-beam techniques also require to take into account the heterogeneity of these geomaterials from the macroscopic to microscopic scales. Several previous studies have demonstrated that PIXE analysis satisfies these analytical conditions. However, application of micro-PIXE analysis is still complex when thin and discontinuous layer of pigment is deposed on the surface of other materials such as rocks or bones. In such case, PIXE imaging could improve the ability to take into account the high heterogeneity of such archaeological objects. In study, we used PIXE imaging system developed at the NewAGLAE facility in order to visualize distribution of elements associated with iron-rich pigment phase. The results obtained show that PIXE maps can improve the identification of the main trace elements specific to the iron mineral phase. By grouping pixels of iron-rich areas and performing quantitative treatment, it was possible to reveal additional trace elements associated to pigment. This study highlights the contribution of PIXE imaging to the identification of elements associated with mineral phases of interest and to use them as proxies to discriminate different geological materials used in archaeological context.

  13. Investigation of Chinese archaic jade by PIXE and μRaman spectrometry

    International Nuclear Information System (INIS)

    Chen, T.H.; Calligaro, T.; Pages-Camagna, S.; Menu, M.

    2004-01-01

    External-beam particle-induced X-ray emission (PIXE) and μRaman spectrometry were used for elemental and structural studies of Chinese archaic nephrite jades of the Guimet Asian Museum in Paris in a non-destructive way. Nephrite is a variety of tremolite-actinolite of the amphibole group, with variable iron and magnesium contents. In the present work, in addition to identification of materials, the cation distribution in nephrite was investigated. Cation order-disorder is related to thermodynamic properties of minerals, and hence associated with geological conditions of the mineral formation. Besides, it plays an important role in the mechanism of coloration. So far, little work has been done on the cation distribution in nephrite. We thus initiated this research expecting to answer open questions concerning art and archaeological issues such as jade provenance and colour. The OH stretching vibration band of nephrite, depending on the electronegativity of the bonded cations, presents a fine structure. The study of this fine structure, together with the total cation content obtained by PIXE, allows estimation of the cation distribution in nephrite. In this study, six jade artefacts, dated from the Neolithic period to the Han dynasty (about 3000 BC to 220 AD), with diverse colours including white, yellow-green, green, dark green and black, were analysed. The data obtained permits establishing a geological database for determination of nephrite provenance and explaining the correlation between colour and cation distribution. (orig.)

  14. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  15. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  16. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  17. Particle induced X-ray emission

    International Nuclear Information System (INIS)

    Cohen, D.D.

    1991-08-01

    The accelerator based ion beam technique of Particle Induced X-ray Emission (PIXE) is discussed in some detail. This report pulls together all major reviews and references over the last ten years and reports on PIXE in vacuum and using external beams. The advantages, limitations, costs and types of studies that may be undertaken using an accelerator based ion beam technique such as PIXE, are also discussed. 25 refs., 7 tabs., 40 figs

  18. External beam radiotherapy for unresectable pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kagami, Yoshikazu; Nishio, Masamichi; Narimatsu, Naoto; Ogawa, Hajime; Betsuyaku, Takashi; Hirata, Kouji; Ikeda, Shigeyuki (Sapporo National Hospital (Japan). Hokkaido Cancer Center)

    1992-04-01

    Between 1980 to 1989, 24 patients with unresectable pancreatic cancer (10 with localized tumor alone and 14 with distant metastases) have been treated with external beam radiation at Sapporo National Hospital, Hokkaido Cancer Center. Response rate of pancreatic tumor treated with external beam radiation was 33.3% (7/21) with no complete response. Median survival time of the patients with localized tumor was 10 months and that of the patients with distant metastases was 3 months. Relief of pain occurred in 92.9% (12/13) of patients having pain due to pancreatic tumor and in 75% (3/4) of patients having pain due to bone metastases. Major complication was gastric ulcer which developed in 5 patients of 21 patients given stomach irradiation. We concluded that unresectable pancreatic cancer would be frequently indicated for radiotherapy. (author).

  19. Influence of the beam energy on the sensitivity of the PIXE methods applied to the detection of Pb in air

    International Nuclear Information System (INIS)

    Caridi, Aurora; Debray, Mario; Hojman, Daniel; Kreiner, A.J.; Santos, Daniel

    1989-01-01

    The air pollution by lead at the downtown area of Buenos Aires city was studied applying the PIXE method. The samples were collected at different seasons of the year. An appreciable reduction of the Pb content was observed on holidays and in summer when there is a lot less of cars in the streets. The influence of the beam energy on the Bremsstrahlung background was studied in order to optimize the sensitivity of the method. The C-12 beam energy was varied from 54 MeV to 30 MeV. The maximum Bremsstrahlung energy of secondary electrons decreased from 10 keV to 5.5 keV. Simultaneously the background radiation was appreciably reduced in the whole spectrum for the lowest beam energy whereas the values for the cross section of X ray production in the Pb L shell were no substantially modified. It is concluded that it is possible to analyze those elements whose characteristic X rays have an energy larger than 5.5 keV. (Author) [es

  20. Study of stained glass window using PIXE-PIGE

    International Nuclear Information System (INIS)

    Weber, G.; Bemden, Y. Vanden; Pirotte, M.; Gilbert, B.

    2005-01-01

    We had the opportunity to study a large panel (100x80cm) containing more than 40 stained glass pieces. Among them several come from restorations having taken place at different periods. The study of this rather complex arrangement has been processed by stages:- the elemental composition of 16 zones were determined: several differences were identified and among them the Na/K ratio which allowed to set three groups of glass type; - the measurement of the Na concentrations by the two techniques give information in bulk (PIGE) and at the near surface (PIXE); the values defined by the (C PIGE -C PIXE) )/C PIGE plotted in function of the historical estimation of the age of the stained glass pieces (original and restored) indicate a real correlation between the two variables; - the red-colored pieces were specially investigated in order to determine which coloration technique was employed (bulk coloration, superficial staining, multilayered flashing, etc.); - the corrosion was investigated by scanning two different worsened zones with a 0.5mm diameter beam spot. This study shows the possibilities of the PIGE-PIXE association, but also points out some weaknesses, which have to be solved by other techniques; unfortunately, in that case, the non-destructive aspect could be lost

  1. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    International Nuclear Information System (INIS)

    Ikeoka, R.A.; Appoloni, C.R.; Rizzutto, M.A.; Silva, T.F.; Bandeira, A.M.

    2013-01-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  2. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    Energy Technology Data Exchange (ETDEWEB)

    Ikeoka, R.A.; Appoloni, C.R., E-mail: renatoikeoka@yahoo.com.br [Universidade Estadual de Londrina (CCE/UEL), PR (Brazil). Departamento de Fisica; Rizzutto, M.A.; Silva, T.F. [Universidade de Sao Paulo (LAMFI/USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Laboratorio de Analise de Materiais por Feixes Ionicos; Bandeira, A.M. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Museu de Arqueologia e Etnologia

    2013-07-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  3. Improvement of detection limits of PIXE by substrate signal reduction

    International Nuclear Information System (INIS)

    Beaulieu, S.; Nejedly, Z.; Campbell, J.L.; Edwards, G.C.; Dias, G.M.

    2002-01-01

    Limits of detection (LODs) for aerosol samples collected using PIXE International cascade impactors, were improved approximately 50% after reducing the cross-sectional area of the analytical beam based on results obtained from microscope photographs of aerosol deposits. Improvements in LODs were most noticeable for selected elements collected on the smaller stages of the impactor (stages 1-3)

  4. PIXE and RBS applied to cultural heritage objects: Complementarity and limitations

    International Nuclear Information System (INIS)

    Morelle, M.; El Masri, Y.; Heitz, Ch.; Prieels, R.; Van Mol, J.; Dran, J.-C.; Salomon, J.; Calligaro, T.; Dubus, M.

    2005-01-01

    This paper reports on the use of PIXE and RBS (resonant and non-resonant RBS) implemented with proton beams to simultaneously analyse light and heavy elements in materials of cultural heritage significance, as exemplified by Russian icons or in lead seals. It is shown that in spite of its poor mass resolution RBS with protons can provide useful information when combined with PIXE. In the case of Russian icons, it is possible to discriminate between an Au-Ag bilayer and an alloy of these metals in the gilds. However, when applied to lead seals RBS with protons encounters a significant limitation due to some deficiency in the available computer programs used for spectrum processing

  5. The new external ion beam analysis setup at the Demokritos Tandem accelerator and first applications in cultural heritage

    International Nuclear Information System (INIS)

    Sokaras, Dimosthenis; Bistekos, Euthimios; Georgiou, Lambros; Salomon, Joseph; Bogovac, Mladen; Aloupi-Siotis, Eleni; Paschalis, Vasilis; Aslani, Ioanna; Karabagia, Sofia; Lagoyannis, Anastasios; Harissopulos, Sotirios; Kantarelou, Vasiliki; Karydas, Andreas-Germanos

    2011-01-01

    At the 5.5 MV Tandem VdG accelerator of the Institute of Nuclear Physics of N.C.S.R. 'Demokritos', Athens, Greece, an external ion-beam set-up has been recently developed and installed. The aim of this development was to integrate the analytical capabilities of the PIXE, RBS and PIGE ion beam techniques in one experimental set-up, so that to attain a complete elemental and near surface structural characterization of samples in an almost non-destructive way and without any limitation concerning their size or conductive state. A careful 3D mechanical drawing optimized the set-up experimental parameters achieving probe dimensions at the millimeter range (1 mm 2 ) and fulfilling the special requirements imposed for optimum performance of the aforementioned techniques, including the possibility to use heavier, than protons, ion beams. For the digital pulse processing of the X-ray, γ-ray and charged particle detector signals, novel hardware and software tools were developed based on a custom FPGA configuration. The first applications were focused in the quality control of materials that have been intentionally contaminated with a particular tracer-element ('tagged' materials). The tagged materials which were developed and tested are technologically authentic replicas of ancient attic ceramics with black glazed decoration. Analytical diagnostic studies were carried out for a few representative paintings of contemporary Greek painters in order to identify and document materials/pigments and techniques and eventually to prevent trade of fakes. Finally, ancient glass beads were also examined with respect to the sodium concentration and its in-depth homogeneity.

  6. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  7. Non-destructive study of ancient documents and books by means of ion beams; Estudio no destructivo de documentos y libros antiguos mediante haces de iones

    Energy Technology Data Exchange (ETDEWEB)

    Ruvalcaba S, J.L.; Monroy, M. [IFUNAM, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2004-07-01

    In this work, a non destructive methodology for the analysis of ancient manuscripts and books using an external beam system and the techniques Particle Induced X-ray Emission Spectroscopy (PIXE) and Rutherford Backscattering Spectrometry (RBS) is presented. This application shows the analytical features of the particle accelerator based techniques for the characterization of this kind of historical materials. This methodology was used for the analysis of inks of an European book from XVII century. This is the first study in Mexico of an ancient book using simultaneously PIXE and RBS non-vacuum techniques. (Author) 21 refs., 9 figs.

  8. Present and future role of ion beam analysis in the study of cultural heritage materials: The example of the AGLAE facility

    International Nuclear Information System (INIS)

    Salomon, J.; Dran, J.-C.; Guillou, T.; Moignard, B.; Pichon, L.; Walter, P.; Mathis, F.

    2008-01-01

    The application of IBA to cultural heritage mostly relies on the use of PIXE because of its high sensitivity and its ease of implementation at atmospheric pressure. The need for depth information not easily available with this technique has conducted to associate RBS also in external beam mode. We have progressively developed a set-up that permits such a combination of techniques either simultaneously or sequentially. The set-up is currently further improved to permit NRA measurement (depth profiles of light elements) in addition to PIXE and RBS. The coupling of all these techniques provides a wealth of information on cultural heritage objects, not easily attainable with any other single method

  9. Proton external beam in the TANDAR Accelerator

    International Nuclear Information System (INIS)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M.

    1998-01-01

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm 2 approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  10. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  11. Target characterization by PIXE, alpha spectrometry and X-ray absorption

    International Nuclear Information System (INIS)

    Kheswa, N.Y.; Papka, P.; Pineda-Vargas, C.A.; Newman, R.T.

    2011-01-01

    We report on the thickness and homogeneity characterization of thin metallic targets of Zr-96 by means of alpha absorption spectrometry, Particle Induced X-ray Emission (PIXE) and X-ray absorption. The target thicknesses determined by means of the above mentioned methods are critically compared. The thicknesses were determined before and after irradiation with a 70 MeV beam of 14 N ions.

  12. Homogeneity study of an Fe impurity in unalloyed Zn using PIXE

    International Nuclear Information System (INIS)

    Gamaz, Faziah; Chaves, Carlos; Waetjen, Uwe

    1999-01-01

    We have studied the distribution of an Fe impurity in unalloyed Zn material along line scans in spots of 1 mm diameter each using PIXE. In order to achieve the necessary precision (1%) in the determination of this low Fe content (about 100 mg/kg), a sufficient counting rate of Fe X-rays is needed without overloading the counting electronics with Zn X-rays at the same time. Therefore, the development of our PIXE analysis system had to take into account: (a) optimising the thickness of a Ni absorber foil in order to selectively reduce the counting rate of Zn without adding an unproportionally high Ni counting rate, (b) implementing a triggered ion beam deflection system capable of handling very high counting rates (up to 8 kcps), (c) developing the spectrum evaluation code to take account of the selective absorption by the Ni foil. The results of our PIXE measurements showed an inhomogeneity in Fe of up to 10%, considered too high to accept this zinc material as a new reference material

  13. Detection and quantitative determination by PIXE of the mutagen Sn2+ in yeast cells

    International Nuclear Information System (INIS)

    Viau, C.M.; Yoneama, M.-L.; Dias, J.F.; Pungartnik, C.; Brendel, M.; Henriques, J.A.P.

    2006-01-01

    The main goal of this work was to determine the concentration of Sn 2+ ions in cells of the yeast Saccharomyces cerevisiae and to correlate their quantity with the genotoxicity of intracellularly accumulated metal ions. The intracellular metal content of yeast cells was determined by PIXE (particle-induced X-ray emission) after cell exposure to SnCl 2 . To that end, a thick target protocol was developed for PIXE analysis. The samples were irradiated with a 2 MeV proton beam, while the induced X-rays were detected with a high-purity germanium detector. The results of the toxicity of SnCl 2 and the PIXE analysis performed with two different yeast strains (haploid and diploid) suggest that the exposure of haploid and diploid yeast to Sn 2+ induces DNA lesions and that the absorption depends on the genetic background of each strain

  14. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  15. Chemical composition of a yellowish rainfall by the application of PIXE and micro-PIXE technique

    International Nuclear Information System (INIS)

    Ma, C.-J.

    2006-01-01

    Information of the chemical properties of rain fallen during the Asian dust (AD) event will help us to better understand the wet scavenging processes of dust particles. In this study, the chemical characteristics of rainwater and individual raindrops fallen during the AD storm have been investigated. The yellowish rainwater and individual raindrops were collected simultaneously in Kyoto, Japan on 7 April 2001. Particle induced X-ray emission (PIXE) was employed in the determination of chemical properties of soluble and insoluble fractions of rainwater. In addition, micro-PIXE was applied to the chemical analysis of residual materials retained in the initial individual raindrops. The pH level of yellowish rainwater was measured around 6.7. In compliance with the general expectation, major components in rainwater were of soil-origin such as Si, K, Ca, Ti and Fe. These soil-related components contributed to as much as 92% of total elemental composition in both soluble and insoluble fractions. By scanning a micro-beam, the residual particle cluster in individual raindrops was reconstructed in terms of an elemental map. This visualized elemental map in fact enabled us not only to estimate the chemical mixing state of raindrop residual particles but also to presume the wet scavenging of dust particles by rainfall

  16. Wavelength dispersive μPIXE setup for the ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Fazinić, S., E-mail: stjepko.fazinic@irb.hr [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Božičević Mihalić, I.; Tadić, T.; Cosic, D.; Jakšić, M. [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Grškovićeva 23, 10000 Zagreb (Croatia)

    2015-11-15

    We have developed a small wavelength dispersive X-ray spectrometer to explore the possibility of performing chemical speciation on microscopic samples utilizing focused ion beams available at the Rudjer Boskovic Institute ion microprobe. Although PIXE spectra are in principle chemically invariant, small influence of chemical effects could be observed even with Si(Li) or SDD detectors. Such chemical effects can be clearly seen with high resolution crystal X-ray spectrometers having energy resolution of several eV. A dedicated vacuum chamber, housing the diffraction crystal, sample holder and CCD X-ray detector, was constructed and positioned behind the main ion microprobe vacuum chamber. Here we will briefly describe the spectrometer, and illustrate its capabilities on measured K X-ray spectra of selected sulfur compounds. We will also demonstrate its abilities to resolve K and M X-ray lines irresolvable by solid state ED detectors usually used in PIXE.

  17. Role of βPix in the kidney

    Directory of Open Access Journals (Sweden)

    Alexander eStaruschenko

    2012-05-01

    Full Text Available Small GTPases function as molecular switches in cell signaling, alternating between an inactive, GDP-bound state, and active GTP-bound state. βPix is one of guanine nucleotide exchange factors (GEFs that catalyze the exchange of bound GDP for ambient GTP. The central goal of this review article is to summarize recent findings on βPix and the role it plays in kidney pathology and physiology. Recent studies shed new light on several key questions concerning the signaling mechanisms mediated by βPix. This manuscript provides a review of the various mechanisms whereby βPix has been shown to function within the kidney through a wide range of actions. Both canonical GEF activity and non-canonical signaling pathways mediated by βPix are discussed. Distribution patterns of βPix in the kidney will be also covered. Much has yet to be discerned, but it is clear that βPix plays a significant role in the kidney.

  18. PIXE/RBS as a tool to study cementitious materials: Application to the dynamic leaching of concrete

    International Nuclear Information System (INIS)

    Llorente, I.; Castellote, M.; Gonzalez-Arrabal, R.; Ynsa, M.D.; Munoz-Martin, A.; Viedma, P.G. de; Castillo, A.; Martinez, I.; Andrade, C.; Zuloaga, P.; Ordonez, M.

    2009-01-01

    The suitability of the application of Ion Beam Analysis (IBA) techniques such as Particle Induced X-ray Emission spectrometry (PIXE) and Rutherford Backscattering Spectrometry (RBS) to elemental depth profiling in concrete is analysed, studying hardened samples of concrete prior to and after a dynamic leaching test. A calibration of the data has been done by comparing the results obtained by IBA techniques with those obtained by Chemical and Thermogravimetric Analysis (TG/DTA). From PIXE and RBS data relevant information about the migration of minor elements, within the concrete matrix after leaching is obtained.

  19. PIXE/RBS as a tool to study cementitious materials: Application to the dynamic leaching of concrete

    Energy Technology Data Exchange (ETDEWEB)

    Llorente, I., E-mail: irene@cenim.csic.e [Centro Nacional de Investigaciones Metalurgicas (CENIM-CSIC), Avda Gregorio del Amo, 8, 28040 Madrid (Spain); Castellote, M. [Instituto de Ciencias de la Construccion ' Eduardo Torroja' (IETcc-CSIC), Serrano Galvache, 4, 28033 Madrid (Spain); Gonzalez-Arrabal, R. [Parque Cientifico de Madrid, Campus de Cantoblanco, Einstein 13, 28049 Madrid (Spain); Ynsa, M.D.; Munoz-Martin, A. [Centro de Microanalisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Viedma, P.G. de; Castillo, A.; Martinez, I.; Andrade, C. [Instituto de Ciencias de la Construccion ' Eduardo Torroja' (IETcc-CSIC), Serrano Galvache, 4, 28033 Madrid (Spain); Zuloaga, P.; Ordonez, M. [Empresa Nacional de Residuos Radiactivos, S.A. (ENRESA), Emilio Vargas, 7, 28043 Madrid (Spain)

    2009-12-15

    The suitability of the application of Ion Beam Analysis (IBA) techniques such as Particle Induced X-ray Emission spectrometry (PIXE) and Rutherford Backscattering Spectrometry (RBS) to elemental depth profiling in concrete is analysed, studying hardened samples of concrete prior to and after a dynamic leaching test. A calibration of the data has been done by comparing the results obtained by IBA techniques with those obtained by Chemical and Thermogravimetric Analysis (TG/DTA). From PIXE and RBS data relevant information about the migration of minor elements, within the concrete matrix after leaching is obtained.

  20. Two-stream instability for a light ion beam-plasma system with external magnetic field

    International Nuclear Information System (INIS)

    Okada, T.; Tazawa, H.

    1992-12-01

    For inertial confinement fusion, a focused light ion beam (LIB) is required to propagate stably through a chamber to a target. We have pointed out that the applied external magnetic field is important for LIB propagation. To investigate the influence of the external magnetic field on the LIB propagation, we analysed the electrostatic dispersion relation of magnetized light ion beam-plasma system. The particle in-cell (PIC) simulation results are presented for a light ion beam-plasma system with external magnetic field. (author)

  1. External proton and Li beams

    International Nuclear Information System (INIS)

    Schuff, Juan A.; Burlon, Alejandro A.; Debray, Mario E.; Kesque, Jose M.; Kreiner, Andres J.; Stoliar, Pablo A.; Naab, Fabian; Ozafran, Mabel J.; Vazquez, Monica E.; Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S.; Ruffolo, M.; Tasat, D.R.; Muhlmann, M. C.

    2000-01-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 μm gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 ± 0.07 MeV, 2.9 ± 0.10 MeV y 1.5 ± 0.1 MeV for protons and 21.4 ± 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with γ-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/μm. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  2. Identification of elements in polutants of Mexico City's atmosphere, using the pixe analysis

    International Nuclear Information System (INIS)

    Diaz-Godoy, R.V.

    1990-01-01

    A review of the fundamentals and actual state in Mexico of the pixe (particle induced X- ray emission) technique are done. Elemental identification in samples of Mexico City's atmosphere taken in two sites is performed using this technique. A 3 MeV proton beam is used to irradiate the samples. Factors (Bremsstrahlung and interference) that difficult the use of the technique are discussed. The sensitivity of the method is enhanced as a main characteristic. It is shown that tje pixe technique together with an appropriate sampling system can be used to study environmental aerosols. Identified elements are bromine, lead, copper, iron, zinc, titanium, vanadium, calcium, potassium, chlorine, sulfur and silicon. Temporal variations of these elements are discussed. (Author)

  3. PIXE analysis of Nigerian flour and bread samples

    Energy Technology Data Exchange (ETDEWEB)

    Olise, Felix S., E-mail: felix_olise@rushpost.com [Department of Physics, Obafemi Awolowo University, Ile-Ife 220005 (Nigeria); Fernandes, Adriana M.; Cristina Chaves, P. [CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Taborda, Ana; Reis, Miguel A. [IST/CTN: Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear (CTN), EN10, 2686-953 Sacavém (Portugal); CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal)

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO{sub 3}) in bread baking led a few authors to report on the chemical methods for the determination of KBrO{sub 3} levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  4. PIXE analysis of Nigerian flour and bread samples

    International Nuclear Information System (INIS)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO 3 ) in bread baking led a few authors to report on the chemical methods for the determination of KBrO 3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples

  5. arXiv The MuPix System-on-Chip for the Mu3e Experiment

    CERN Document Server

    Augustin, Heiko

    2017-02-11

    Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $\\mu^+ \\rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\\,\\mu$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field provides precise vertex and momentum information. The MuPix chip combines pixel sensor cells with integrated analog electronics and a periphery with a complete digital readout. The MuPix7 is the first HV-MAPS prototype implementing all functionalities of the final sensor including a readout state machine and high speed serialization with 1.25 Gbit/s data output, allowing for a streaming readout in parallel to the data taking. The observed efficiency of the MuPix7 chip including the full readout system is $\\geq99\\%$ in a high rate test beam.

  6. Micro-ERDA, micro-RBS and micro-PIXE techniques in the investigation of fish otoliths

    International Nuclear Information System (INIS)

    Huszank, R.; Simon, A.; Szilagyi, E.; Keresztessy, K.; Kovacs, I.

    2009-01-01

    Elemental distribution in the otolith of the fresh water fish burbot (Lota lota L.) collected in Hungary was measured with Elastic Recoil Detection Analysis (ERDA), Rutherford Backscattering Spectrometry (RBS) and as a complementary technique, Particle-Induced X-ray Emission (PIXE) with a focussed ion beam of 1.5 x 1.5 μm 2 spot size. The organic- and inorganic-rich regions of the otolith are distinguished and they are presented as hydrogen and calcium maps at depth regions of 0-70, 70-140 and 140-210 nm. The textured surface of the sample and its porosity were characterized from the effect on the RBS spectra. The oxygen and carbon PIXE elemental maps can also be used to identify the organic- and inorganic-rich regions of the otolith. The calcium map was found to be more homogeneous because the otolith structure is averaged in a larger depth. The trace elements Fe, Zn and Sr were detected only in very low concentration by micro-PIXE.

  7. Micro-ERDA, micro-RBS and micro-PIXE techniques in the investigation of fish otoliths

    Energy Technology Data Exchange (ETDEWEB)

    Huszank, R. [Institute of Nuclear Research of the Hungarian Academy of Sciences, P.O. Box 51, H-4001 Debrecen (Hungary)], E-mail: huszank@atomki.hu; Simon, A. [Institute of Nuclear Research of the Hungarian Academy of Sciences, P.O. Box 51, H-4001 Debrecen (Hungary); Szilagyi, E. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary); Keresztessy, K. [Department of Fish Culture, Institute of Environmental and Landscape Management, Szent Istvan University, Pater K.u.1, H-2103 Goedoello (Hungary); Kovacs, I. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2009-06-15

    Elemental distribution in the otolith of the fresh water fish burbot (Lota lota L.) collected in Hungary was measured with Elastic Recoil Detection Analysis (ERDA), Rutherford Backscattering Spectrometry (RBS) and as a complementary technique, Particle-Induced X-ray Emission (PIXE) with a focussed ion beam of 1.5 x 1.5 {mu}m{sup 2} spot size. The organic- and inorganic-rich regions of the otolith are distinguished and they are presented as hydrogen and calcium maps at depth regions of 0-70, 70-140 and 140-210 nm. The textured surface of the sample and its porosity were characterized from the effect on the RBS spectra. The oxygen and carbon PIXE elemental maps can also be used to identify the organic- and inorganic-rich regions of the otolith. The calcium map was found to be more homogeneous because the otolith structure is averaged in a larger depth. The trace elements Fe, Zn and Sr were detected only in very low concentration by micro-PIXE.

  8. Micro-PIXE for single cell analysis

    International Nuclear Information System (INIS)

    Ortega, Richard

    2012-01-01

    The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The combination of micro-PIXE with RBS and STIM (Scanning Transmission Ion Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STIM analysis provides high spatial resolution imaging (< 200 nm) and excellent mass sensitivity (< 0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron x-ray fluorescence. Examples of micro-PIXE studies for sub-cellular imaging of trace elements in various fields of interest will be presented: in patho-physiology of trace elements involved in neurodegenerative diseases such as Parkinson's disease, and in toxicology of metals such as cobalt. (author)

  9. Pix proteins and the evolution of centrioles.

    Science.gov (United States)

    Woodland, Hugh R; Fry, Andrew M

    2008-01-01

    We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT) system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  10. PIXE study on absorption of arsenate and arsenite by arsenic hyperaccumulating fern (Pteris vittata)

    International Nuclear Information System (INIS)

    Yamazaki, H.; Ishii, K.; Matsuyama, S.

    2008-01-01

    Pytoremediation using an arsenic hyperaccumulator, Petris vittata L., has generated an increasing interest worldwide due to both environmentally sound and cost effectiveness. However the mechanism of arsenic accumulation by this fern is not clear at this time. This study examined the uptake of arsenate (As(V)) and arsenite (As(III)) by a hydroponic culture of Pteris vittata using both in-air submilli-PIXE for different parts of the fern and in-air micro-PIXE for the tissue cells. These PIXE analysis systems used 3 MeV proton beams from a 4.5-MV single-ended Dynamitron accelerator at Tohoku University, Japan. The fern took up both arsenate and arsenite from hydroponic solutions which were spiked with 50 mg of arsenic per litter. Final amount of arsenic accumulation in the fern is 1,500 mg per kg (wet weight) of the plant biomass in arsenite treatment and 1,100 mg per kg in arsenate treatment. Arsenic accumulation was not observed at the root parts of the ferns. The in-vivo mapping of elements by submilli-PIXE analyses on the fern laminas showed the arsenic accumulation in the edges of a pinna. The micro-PIXE analyses revealed arsenic maps homogeneously distributed in cells of the lamina, stem and rhizome of the fern. These results indicate that arsenic, both arsenate and arsenite in a contaminated medium are translocated quickly from roots to fronds of Pteris vittata, and distributes homogeneously into tissue cells of the fern laminas. (author)

  11. Characterization of mercury gilding art objects by external proton beam

    International Nuclear Information System (INIS)

    Corregidor, V.; Alves, L.C.; Barradas, N.P.; Reis, M.A.; Marques, M.T.; Ribeiro, J.A.

    2011-01-01

    The fire gilding is one of the methods used by the ancient goldsmiths to obtain a rich, metallic glow and durable golden appearance in ornamental objects. This layer is characterized, among others, by its thickness (several microns) a diffusion profile and a Hg content (between 0 and 21 wt.%) depending on the temperatures achieved during the process. Gilded sacral art objects dated from the XVI to the XVIII centuries, belonging to the Casa-Museu Dr. Anastácio Gonçalves Collection (Lisbon) were analyzed using the external ion microprobe at Nuclear and Technological Institute, Lisbon. The average concentrations of the homogeneous areas were calculated with GUPIX, DATTPIXE and NDF codes showing very similar results. The RBS and PIXE spectra from the same point were collected simultaneously and analyzed together with NDF-LibCPIXE in order to find self-consistent solutions. Profile concentration on particular Au-reach points was extracted. Different Hg and Au/Ag ratio have been found in the pieces dating from different centuries.

  12. PIXE analyses over a long period: The case of Neolithic variscite jewels from Western Europe (5th–3th millennium BC)

    Energy Technology Data Exchange (ETDEWEB)

    Querré, G., E-mail: guirec.querre@univ-rennes1.fr [Laboratoire Archéosciences, UMR 6566 CReAAH, Université de Rennes 1, Rennes (France); Calligaro, T. [Centre de Recherche et de Restauration des Musées de France, Palais du Louvre, Paris (France); Domínguez-Bella, S. [UGEA-PHAM, Departamento de Ciencias de la Tierra, Universidad de Cádiz (Spain); Cassen, S. [Laboratoire de Recherches Archéologiques, UMR 6566 CReAAH, Nantes (France)

    2014-01-01

    PIXE analysis of archeological variscite beads and pendants from the Neolithic period that were excavated in Spain, Portugal and France and of variscite geological references samples from European occurrences were carried out from 1999 to 2013 in order to trace back the circulation of this precious gemstone over three millennia. Transformations of the AGLAE external beam system and progress in spectrum processing have induced some apparent compositional variation, affecting in particular the phosphorus/aluminum ratio. This long term evolution has been taken into account with the help of geostandards to build a large and coherent geochemical database of minor and trace elements in variscite. This database allowed us to determine the provenance of the raw material and thus of the circulation of the jewels.

  13. PIXE analyses over a long period: The case of Neolithic variscite jewels from Western Europe (5th–3th millennium BC)

    International Nuclear Information System (INIS)

    Querré, G.; Calligaro, T.; Domínguez-Bella, S.; Cassen, S.

    2014-01-01

    PIXE analysis of archeological variscite beads and pendants from the Neolithic period that were excavated in Spain, Portugal and France and of variscite geological references samples from European occurrences were carried out from 1999 to 2013 in order to trace back the circulation of this precious gemstone over three millennia. Transformations of the AGLAE external beam system and progress in spectrum processing have induced some apparent compositional variation, affecting in particular the phosphorus/aluminum ratio. This long term evolution has been taken into account with the help of geostandards to build a large and coherent geochemical database of minor and trace elements in variscite. This database allowed us to determine the provenance of the raw material and thus of the circulation of the jewels

  14. Improvement in the determination of elemental concentrations in PIXE analyses using artificial neural system

    International Nuclear Information System (INIS)

    Correa, R.; Dinator, M.I.; Morales, J.R.; Miranda, P.A.; Cancino, S.A.; Vila, I.; Requena, I.

    2008-01-01

    An Artificial Neural System, ANS, has been designed to operate in the analysis of spectra obtained from a PIXE (Proton Induced X-ray Emissions) application. The special designed ANS was used in the calculation of the concentrations of the major elements in the samples. Neural systems using several feed-forward ANN of similar topology working in parallel were trained with error back propagation algorithm using sets of spectra of known elemental concentrations. Following the training phase of the neural networks, other PIXE spectra were analyzed with this methodology providing unknown elemental concentrations. ANS results were compared with results obtained by traditional computer codes like AXIL and GUPIX, obtaining correlations factors close to one. The rather short time required to process each spectrum, of the order of microseconds, allows fast analysis of a large number of samples. Here we present applications of ANS in the PIXE analyses of samples of organic nature like liver, gills and muscle from fishes. ANS results were compared with elemental concentrations obtained in a previous application where a single ANN was used for each analyzed element. PIXE analyses were performed at the Nuclear Physics Laboratory of the University of Chile, using 2.2 MeV proton beams provided by a Van de Graaff accelerator. (author)

  15. Optimized readout configuration for PIXE spectrometers based on Silicon Drift Detectors: Architecture and performance

    International Nuclear Information System (INIS)

    Alberti, R.; Grassi, N.; Guazzoni, C.; Klatka, T.

    2009-01-01

    An optimized readout configuration based on a charge preamplifier with pulsed-reset has been designed for Silicon Drift Detectors (SDDs) to be used in Particle Induced X-ray Emission (PIXE) measurements. The customized readout electronics is able to manage the large pulses originated by the protons backscattered from the target material that would otherwise cause significant degradation of X-ray spectra and marked increase in dead time. In this way, the excellent performance of SDDs can be exploited in high-quality proton-induced spectroscopy of low- and medium-energy X-rays. This paper describes the designed readout architecture and the performance characterization carried out in a PIXE setup with MeV proton beams.

  16. Pix proteins and the evolution of centrioles.

    Directory of Open Access Journals (Sweden)

    Hugh R Woodland

    Full Text Available We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  17. Turbo Pascal Computer Code for PIXE Analysis

    International Nuclear Information System (INIS)

    Darsono

    2002-01-01

    To optimal utilization of the 150 kV ion accelerator facilities and to govern the analysis technique using ion accelerator, the research and development of low energy PIXE technology has been done. The R and D for hardware of the low energy PIXE installation in P3TM have been carried on since year 2000. To support the R and D of PIXE accelerator facilities in harmonize with the R and D of the PIXE hardware, the development of PIXE software for analysis is also needed. The development of database of PIXE software for analysis using turbo Pascal computer code is reported in this paper. This computer code computes the ionization cross-section, the fluorescence yield, and the stopping power of elements also it computes the coefficient attenuation of X- rays energy. The computer code is named PIXEDASIS and it is part of big computer code planed for PIXE analysis that will be constructed in the near future. PIXEDASIS is designed to be communicative with the user. It has the input from the keyboard. The output shows in the PC monitor, which also can be printed. The performance test of the PIXEDASIS shows that it can be operated well and it can provide data agreement with data form other literatures. (author)

  18. Network application of PIXE trace element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Hattori, T.

    2003-01-01

    Particle Induced X-ray Emission (PIXE) is a very sensitive analytical technique for determinations of trace elements. But the number of users is limited because there are not so much accelerators which can be used easily. On the other hand, PIXE is a typical machine analysis which can easily analyze automatically and make online data acquisition system. If there is useful online data handling system then PIXE analysis should be more useful for many persons. Therefore we develop to online PIXE facility at Tokyo Institute of Technology VdG laboratory and use it for environmental educations. (author)

  19. External beam radiotherapy in the management of ovarian carcinoma

    International Nuclear Information System (INIS)

    Reinfuss, Marian; Zbigniew, Kojs; Skolyszewski, Jan

    1993-01-01

    Between 1970 and 1983, 345 patients with ovarian cancer clinical stage I, II and III were irradiated postoperatively. Five-year NED survival was achieved in 41.7% of patients. The most important prognostic factors were histological grade and clinical stage of cancer. Postoperative external beam radiotherapy appeared to be highly efficient for the patients with microscopic residual disease, giving 70% 5-year survival, and moderately efficient for patients with small, i.e. ≤3 cm in diameter residual disease, giving 40% 5-year survival. The optimal technique of irradiation appeared to be the irradiation given to the entire abdominal cavity with additional irradiation coned down to the pelvis. External beam radiotherapy was ineffective in patients with gross residual disease, i.e. >3 cm in diameter, and useless as palliative treatment given to patients with inoperable cancer of the ovary. (author). tabs., figs

  20. Development and applications of STIM- and PIXE-tomography: A review

    International Nuclear Information System (INIS)

    Michelet, C.; Barberet, P.; Moretto, P.; Seznec, H.

    2015-01-01

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  1. Development and applications of STIM- and PIXE-tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Michelet, C., E-mail: michelet@cenbg.in2p3.fr; Barberet, P., E-mail: barberet@cenbg.in2p3.fr; Moretto, P., E-mail: moretto@cenbg.in2p3.fr; Seznec, H., E-mail: herve.seznec@cenbg.in2p3.fr

    2015-11-15

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  2. PIXE as an analytical/educational tool

    International Nuclear Information System (INIS)

    Williams, E.T.

    1991-01-01

    The advantages and disadvantages of PIXE as an analytical method will be summarized. The authors will also discuss the advantages of PIXE as a means of providing interesting and feasible research projects for undergraduate science students

  3. Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE

    Science.gov (United States)

    Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.

    2017-08-01

    Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p < 0.005) while the levels of Ca, Cr and Ni were lower (p < 0.005) in the cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.

  4. VeloPix ASIC for the LHCb VELO Upgrade

    CERN Multimedia

    Cid Vidal, Xabier

    2015-01-01

    The LHCb Vertex Detector (VELO) will be upgraded in 2018 along with the other subsystems of LHCb in order to enable full detector readout at 40 MHz. LHCb will run without a hardware trigger and all data will be fed directly to the software triggering algorithms in the CPU farm. The upgraded VELO is a lightweight silicon hybrid pixel detector with 55 um square pixels, operating in vacuum in close proximity to the LHC beams. The readout will be provided by a dedicated front end ASIC, dubbed VeloPix, matched to the LHCb luminosity requirements. VeloPix is a binary pixel chip with a matrix of 256 x 256 pixels, covering an area of 2 cm^2. It is designed in a 130 nm CMOS technology, and is closely related to the Timepix3, from the Medipix family of ASICs. The principal challenge that the chip has to meet is a hit rate of up to 900 Mhits/s/ASIC, resulting in a data rate of more than 16 Gbit/s. Combining pixels into groups of 2x4 super-pixels enables the use of shared logic and a reduction of bandwidth due to combine...

  5. Dose-rate effects in external beam radiotherapy redux

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Gerweck, Leo E.; Zaider, Marco; Yorke, Ellen

    2010-01-01

    Recent developments in external beam radiotherapy, both in technical advances and in clinical approaches, have prompted renewed discussions on the potential influence of dose-rate on radio-response in certain treatment scenarios. We consider the multiple factors that influence the dose-rate effect, e.g. radical recombination, the kinetics of sublethal damage repair for tumors and normal tissues, the difference in α/β ratio for early and late reacting tissues, and perform a comprehensive literature review. Based on radiobiological considerations and the linear-quadratic (LQ) model we estimate the influence of overall treatment time on radio-response for specific clinical situations. As the influence of dose-rate applies to both the tumor and normal tissues, in oligo-fractionated treatment using large doses per fraction, the influence of delivery prolongation is likely important, with late reacting normal tissues being generally more sensitive to the dose-rate effect than tumors and early reacting tissues. In conventional fractionated treatment using 1.8-2 Gy per fraction and treatment times of 2-10 min, the influence of dose-rate is relatively small. Lastly, the dose-rate effect in external beam radiotherapy is governed by the overall beam-on-time, not by the average linac dose-rate, nor by the instantaneous dose-rate within individual linac pulses which could be as high as 3 x 10 6 MU/min.

  6. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  7. Bilateral Rhegmatogenous Retinal Detachment during External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Takako Hidaka

    2016-06-01

    Full Text Available Herein, we report a case of nontraumatic bilateral rhegmatogenous retinal detachment (RRD during external beam radiotherapy for nonocular tumor, presented as an observational case study in conjunction with a review of the relevant literature. A 65-year-old male was referred to our hospital due to bilateral RRD. He underwent a biopsy for a tumor of the left frontal lobe 4 months prior to presentation, and the tumor had been diagnosed as primary central nerve system B-cell type lymphoma. He received chemotherapy and external beam radiotherapy for 1 month. There were no traumatic episodes. Bilateral retinal detachment occurred during a series of radiotherapies. Simultaneous nontraumatic bilateral retinal detachment is rare. The effects of radiotherapy on ocular functionality, particularly in cases involving retinal adhesion and vitreous contraction, may include RRD. Thus, it is necessary to closely monitor the eyes of patients undergoing radiotherapy, particularly those undergoing surgery for retinal detachment and those with a history of photocoagulation for retinal tears, a relevant family history, or risk factors known to be associated with RRD.

  8. An open experiment of a submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, S.; Ishii, K.; Yamazaki, H.; Iwasaki, S.; Tokai, Y.; Sugimoto, A.; Endo, H.; Ozawa, T.

    1999-01-01

    We have annually held an open experiment of PIXE analysis since 1996 to get people's understanding on nuclear technology and radiation science. Up to the present, more than 270 participants joined and enjoyed the open experiments. This year, we demonstrated performance of a submilli-PIXE camera and had sixty-nine participants in the open experiment of PIXE. Elemental spatial distribution images gave deep impression to the participants. Half of the participants were high school students since the open experiment of PIXE was held during the period of open campus of Tohoku University. About ten percents of the participants were junior high school students. Our open experiment of PIXE was very effective to arouse public interest in radiation science and nuclear technology. (author)

  9. External beam radiation for retinoblastoma: Results, patterns of failure, and a proposal for treatment guidelines

    International Nuclear Information System (INIS)

    Hernandez, J. Carlos; Brady, Luther W.; Shields, Jerry A.; Shields, Carol L.; Potter, Patrick de; Karlsson, Ulf L.; Markoe, Arnold M.; Amendola, Beatriz E.; Singh, Arun

    1996-01-01

    Purpose: To analyze treatment results and patterns of failure following external beam radiation for retinoblastoma and propose treatment guidelines according to specific clinical variables. Methods and Materials: We analyzed 27 patients (34 eyes) with retinoblastoma who received external beam radiation as initial treatment at Hahnemann University Hospital from October 1980 to December 1991 and have been followed for at least 1 year. Of the 34 eyes, 14 were Groups I-II (Reese-Ellsworth classification), 7 were Group III, and 13 were Groups IV-V. Doses ranged from 34.5-49.5 Gy (mean 44.3 Gy, median 45 Gy) in 1.5-2.0 Gy fractions generally delivered through anterior and lateral wedged pair fields. Results: At a mean follow up of 35.2 months (range 12-93 months), local tumor control was obtained in 44% (15 out of 34) of eyes with external beam radiation alone. Salvage therapy (plaque brachytherapy, cryotherapy, and/or photocoagulation) controlled an additional 10 eyes (29.5%), so that overall ocular survival has been 73.5%. Local tumor control with external beam radiotherapy alone was obtained in 78.5% (11 out of 14) of eyes in Groups I-II, but in only 20% (4 out of 20) of eyes in Groups III-V. A total of 67 existing tumors were identified prior to treatment in the 34 treated eyes and local control with external beam radiation alone was obtained in 87% (46 out of 53) of tumors measuring 15 mm or less and in 50% (7 out of 14) of tumors measuring more than 15 mm. When analyzing patterns of failure in the 19 eyes that relapsed, a total of 28 failure sites were identified and consisted of progression of vitreous seeds in seven instances (25% of failure sites) recurrences from previously existing tumors in 10 instances (36% of failure sites) and development of new tumors in previously uninvolved retina in 11 instances (39% of failure sites). Conclusions: 1) We find that external beam radiation to a dose of 45 Gy in fractions of 1.5 to 2.0 Gy provides adequate tumor control

  10. PIXE facility at Centro Atomico Bariloche

    Energy Technology Data Exchange (ETDEWEB)

    Limandri, S.; Rodriguez, L. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Olivares, C.; Bernardi, G. [Centro Atomico Bariloche, Comision Nacional de Energia Atomica, San Carlos de Bariloche, Rio Negro (Argentina); Suarez, S. [lnstituto Balseiro, Universidad Nacional de Cuyo, San Carlos de Bariloche, Rio Negro (Argentina)

    2013-07-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  11. PIXE facility at Centro Atomico Bariloche

    International Nuclear Information System (INIS)

    Limandri, S.; Rodriguez, L.; Olivares, C.; Bernardi, G.; Suarez, S.

    2013-01-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  12. Hair analysis using PIXE

    International Nuclear Information System (INIS)

    Li Hongkou.

    1983-10-01

    A simple new technique for examining single hair strands to obtain linear mass densities, longitudinal profiles and transverse distribution of each trace element is described. It is primarily based upon the PIXE technique, in combination with proton back- scattering. The three main components of this technique are: 1) An accurate way of using an interpolation method to evaluate the magnitude of the correction factor accounting for the proton energy loss and X-ray absorption in the bulk of the hair is formulated; 2) A simple method to qualitatively determine the transverse distribution of each trace element in a hair is in- troduced and proved to be effective; 3) Proton back-scattering is proved to be capable of providing an ideal linear measure of the geometric hair diameter, one of the most important parameters in quantifying the results of PIXE measurements in mass concentrations. Using the technique, a PIXE system designed and constructed for routine longitudinal scanning of single hair strands is also described. (Author)

  13. External Beam Radiotherapy in Metastatic Bone Pain from Solid ...

    African Journals Online (AJOL)

    Key Words: Bone, metastasis, radiotherapy, pain, control randomized ... described the efficacy of external beam radiotherapy in pain .... life of patients with multiple myeloma. Eur. J. ... Rades D, Jeremic B, Hoskin PJ: The Role of ... randomised multicenter trial on single fraction ... "The subjective experience of acute pain. An.

  14. An indirect method to measure the electric charge deposited on insulators during PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dinator, M.I.; Cancino, S.A.; Miranda, P.A. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile); Morales, J.R. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile)], E-mail: rmorales@uchile.cl; Seelenfreund, A. [Universidad Academia de Humanismo Cristiano, Condell 343, Providencia, Santiago (Chile)

    2007-10-15

    Total charge deposited by a proton beam in an insulator during PIXE analysis has been indirectly determined using a Mylar film coated with cobalt. Elemental concentrations in the samples, pieces of volcanic glass, were obtained and compared to concentrations determined by ICP OES on the same samples. The strong agreement between these results shows the accuracy of the charge determined by this method.

  15. The relationship between external beam radiotherapy dose and chronic urinary dysfunction - A methodological critique

    International Nuclear Information System (INIS)

    Rosewall, Tara; Catton, Charles; Currie, Geoffrey; Bayley, Andrew; Chung, Peter; Wheat, Janelle; Milosevic, Michael

    2010-01-01

    Purpose: To perform a methodological critique of the literature evaluating the relationship between external beam radiotherapy dose/volume parameters and chronic urinary dysfunction to determine why consistent associations between dose and dysfunction have not been found. Methods and materials: The radiotherapy literature was reviewed using various electronic medical search engines with appropriate keywords and MeSH headings. Inclusion criteria comprised of; English language articles, published between 1999 and June 2009, incorporating megavoltage external beam photons in standard-sized daily fraction. A methodological critique was then performed, evaluating the factors affected in the quantification of radiotherapy dose and chronic urinary dysfunction. Results: Nine of 22 eligible studies successfully identified a clinically and statistically significant relationship between dose and dysfunction. Accurate estimations of external beam radiotherapy dose were compromised by the frequent use of dosimetric variables which are poor surrogates for the dose received by the lower urinary tract tissue and do not incorporate the effect of daily variations in isocentre and bladder position. The precise categorization of chronic urinary dysfunction was obscured by reliance on subjective and aggregated toxicity metrics which vary over time. Conclusions: A high-level evidence-base for the relationship between external beam radiotherapy dose and chronic urinary dysfunction does not currently exist. The quantification of the actual external beam dose delivered to the functionally important tissues using dose accumulation strategies and the use of objective measures of individual manifestations of urinary dysfunction will assist in the identification of robust relationships between dose and urinary dysfunction for application in widespread clinical practice.

  16. Development of in-air micro-PIXE analysis and data sharing systems in JAERI Takasaki

    International Nuclear Information System (INIS)

    Sakai, Takuro; Kamiya, Tomihiro; Oikawa, Masakazu

    2000-01-01

    An external scanning ion microbeam system has been developed for in-air micro-PIXE analysis at JAERI Takasaki. The analysis system is widely used for various researches in recent years. The system consists of the external scanning ion microbeam system, a multi-parameter data acquisition system, a file transfer protocol (FTP) server and analysis software. The software of the system provides a graphical user interface for interaction between users and an experimental setup. The server is connected to the Internet and allows remote users to access the experimental data. (author)

  17. Pittsburgh rainwater analysis by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K C; Cohen, B L; Frohliger, J O; Shabason, L

    1976-01-01

    Concentrations of thirteen elements in rainwater from the Pittsburgh, Pa., area were analysed by Charged Particle Induced X-ray Emission (PIXE). They were compared to rainwater in a rural area and air particulates in Pittsburgh. Local and non-local contributions are discussed. Washout ratios were calculated and found to be larger for smaller size particles, contrary to general belief. The work demonstrates the convenience of using PIXE.

  18. Implementation of a system for external audits beam radiation therapy in terms of reference no

    International Nuclear Information System (INIS)

    Alonso Samper, Jose Luis; Dominguez, Lourdes; Alert Silva, Jose; Alfonso Laguardia, Rodolfo; Larrinaga Cortina, Eduardo; Garcia Yip, Fernando; Rodriguez Machado, Jorge; Morales Lopez, Jorge Luis; Silvestre Patallo, Ileana

    2009-01-01

    This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made.This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made. Centers were audited with external beam high-energy Co-60, 6 MV and 15 MV and were considered 4 treatment planning systems (TPS): AMEPLAN, Theraplan Plus, Precise Plan and MIRS to calculate doses prescribed in each test case. All measurements were acquired by the audit team using the anthropomorphic phantom CIRS, Semiflex chamber PTW 31010 and PTW electrometer STATES. The implementation and development of the external audits of beams radiotherapy in terms of 'no reference' has brought an improvement in both clinical aspects of treatment and the radiation safety and the quality control, has given us greater confidence and for this reason we believe has become essential. (Author)

  19. PIXE Analysis and source identification of airborne particulate matter collected in Downtown Havana City

    International Nuclear Information System (INIS)

    Perez, G.; Pinnera, I; Ramos, M; Guibert, R; Molina, E.; Martinez, M.; Fernandez, A.; Aldape, F.; Flores, M.

    2009-01-01

    A set of samples containing airborne particulate matter (in two particle size fraction PM10 and PM2,5) collected during five months from November 2006 to April 2007 in a urban area of Havana City were analyzed by Particle-Induced X-ray Emission (PIXE) technique and the concentrations of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were determined consistently in both particle size fractions with minimum detection limits in the range of ng/m3. A Gent air sampler was used for the aerosol collection in PM10 and PM2,5 particles simultaneously and the PIXE elemental analysis were performed using a proton beam of 2.5 MeV from the 2 MV Van de Graff Tandetron Accelerator at the ININ PIXE Laboratory in Mexico. The analytical database provided by PIXE was statistically analyzed in order to determine the promising local pollution sources. The statistical techniques of Multivariate Factor Analysis in combination with the Principal Component Analysis methods were applied to this data and allowed identifying five main pollution sources of airborne particulate matter (PM10 and PM2,5) collected in this area. The main (local) identified sources were: soil dust, sea spray, industry, fossil fuel combustion from motor vehicles and burnings or incinerations of diverse materials. A general discussion about these results is presented in this work. (Author)

  20. Characterization of the Teotihuacan mural painting: application of the external particle beam as non destructive technique

    International Nuclear Information System (INIS)

    Martinez, C.; Manzanilla, L.; Ruvalcaba, J.L.; Ontalba, M.A.

    2005-01-01

    The characterization of technical indicators contained in the painting mural should follow a minim methodology from their discovery in the archaeological excavations until their analysis in the laboratory, with the purpose of rescuing diagnostic elements that mark the stages of socio cultural development in the towns. With this spirit it was carried out the present study analyzing some fragments of the Teotihuacan mural painting. The analysis consisted on applying some of the analytical techniques with particle beams used for archaeometry like the Proton induced X-ray emission (PIXE) and the particle elastic backscattering (RBS), due to it is treated of complementary techniques, very sensitive, of multielemental character, but mainly because its are non destructive analytical techniques. (Author)

  1. New developments for the analysis of archaeological and artistic artifacts by optical and ion beam methods at LAMFI

    International Nuclear Information System (INIS)

    Rizzutto, Marcia A.; Tabacniks, Manfredo H.; Barbosa, Marcel D. L.; Added, Nemitala; Curado, Jessica F.; Kajiya, Elizabet M.; Campos, Pedro H.O.V. de

    2011-01-01

    Full text: Since 2005, the analysis of artistic and cultural heritage objects at LAMFI-USP (Laboratorio de Analises de Materiais com Feixes Ionicos), initially restricted to ion beam methods, is growing steadily. Since then, alternative methodologies and procedures have been incorporated to better characterize these objects, that possess distinctive physical characteristics and also due to their high cultural and monetary value. The examinations were expanded to other non-destructive analytical techniques like portable XRF (X-ray fluorescence) analysis, X-ray radiography, visible, UV (ultraviolet) and IR (infrared) light imaging that are helping to better understand these art objects, particularly paintings, where the techniques are helping to access the conservation state and also reveal underlying drawings, which help understanding the creative process of the artist. The external beam arrangement at LAMFI was recently updated for simultaneous PIXE (Particle induced X-ray emission), RBS (Rutherford back scattering), PIGE (Particle induced gamma-ray emission) and IBL (Ion beam luminescence) analysis in open air. The new setup comprises a 2 π star-like detector assembly with 7 collimated telescopes: two openings have laser beams for optical alignment of the target, 2 are used for X-ray detectors, 1 for a particle detector, 1 for an optical spectrometer, and 1 for a image. The particle and X-ray detector telescopes can be evacuated to reduce signal losses. The 2 telescopes with the X-ray detectors have absorbers to selectively filter low energy X-rays, optimizing the PIXE detection limits. The beam exit window is made of an 8 μm aluminum foil to monitoring integrated beam charge by measuring the Al gamma rays with a NaI detector. The geometry and materials of the assembly have been carefully designed to shield the X-ray detectors from measuring the X-rays from the exit beam window as well as reducing the detection of Ar K α from the in air beam path. The new

  2. New developments for the analysis of archaeological and artistic artifacts by optical and ion beam methods at LAMFI

    Energy Technology Data Exchange (ETDEWEB)

    Rizzutto, Marcia A.; Tabacniks, Manfredo H.; Barbosa, Marcel D. L.; Added, Nemitala; Curado, Jessica F.; Kajiya, Elizabet M.; Campos, Pedro H.O.V. de [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Fisica

    2011-07-01

    Full text: Since 2005, the analysis of artistic and cultural heritage objects at LAMFI-USP (Laboratorio de Analises de Materiais com Feixes Ionicos), initially restricted to ion beam methods, is growing steadily. Since then, alternative methodologies and procedures have been incorporated to better characterize these objects, that possess distinctive physical characteristics and also due to their high cultural and monetary value. The examinations were expanded to other non-destructive analytical techniques like portable XRF (X-ray fluorescence) analysis, X-ray radiography, visible, UV (ultraviolet) and IR (infrared) light imaging that are helping to better understand these art objects, particularly paintings, where the techniques are helping to access the conservation state and also reveal underlying drawings, which help understanding the creative process of the artist. The external beam arrangement at LAMFI was recently updated for simultaneous PIXE (Particle induced X-ray emission), RBS (Rutherford back scattering), PIGE (Particle induced gamma-ray emission) and IBL (Ion beam luminescence) analysis in open air. The new setup comprises a 2 {pi} star-like detector assembly with 7 collimated telescopes: two openings have laser beams for optical alignment of the target, 2 are used for X-ray detectors, 1 for a particle detector, 1 for an optical spectrometer, and 1 for a image. The particle and X-ray detector telescopes can be evacuated to reduce signal losses. The 2 telescopes with the X-ray detectors have absorbers to selectively filter low energy X-rays, optimizing the PIXE detection limits. The beam exit window is made of an 8 {mu}m aluminum foil to monitoring integrated beam charge by measuring the Al gamma rays with a NaI detector. The geometry and materials of the assembly have been carefully designed to shield the X-ray detectors from measuring the X-rays from the exit beam window as well as reducing the detection of Ar K {alpha} from the in air beam path. The

  3. A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms

    International Nuclear Information System (INIS)

    Narayana, V.; Sahijdak, W.M.; Orton, C.G.

    1997-01-01

    Purpose: Radiation treatment of gynecological neoplasms, such as cervical carcinoma, usually combines external radiation therapy with one or more intracavitary brachytherapy applications. Although the dose from external beam radiation therapy and brachytherapy can be calculated and displayed in 3D individually, the dose distributions are not combined. At most, combined point doses are calculated for select points using various time-dose models. In this study, we present a methodology to combine external beam and brachytherapy treatments for gynecological neoplasms. Material and Methods: Three dimensional bio-effect treatment planning to obtain complication probability has been outlined. CT scans of the patient's pelvis with the gynecological applicator in place are used to outline normal tissue and tumor volumes. 3D external beam and brachytherapy treatment plans are developed separately and an external beam dose matrix and a brachytherapy dose matrix was calculated. The dose in each voxel was assumed to be homogeneous. The physical dose in each voxel of the dose matrix was then converted into extrapolated response dose (ERD) based on the linear quadratic model that accounts for the dose per fraction, number of fractions, dose rate, and complete or incomplete repair of sublethal damage (time between fractions). The net biological dose delivered was obtained by summing the ERD grids from external beam and brachytherapy since there was complete repair of sublethal damage between external beam and brachytherapy treatments. The normal tissue complication probability and tumor control probability were obtained using the biological dose matrix based on the critical element model. Results: The outlined method of combining external beam and brachytherapy treatments was implemented on gynecological treatments using an applicator for brachytherapy treatments. Conclusion: Implementation of the biological dose calculation that combine different modalities is extremely useful

  4. Prospective survey of erectile dysfunction after external beam radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Kikuchi, Eiji; Ando, Toshiyuki; Nagata, Hirohiko; Miyajima, Akira; Nakagawa, Ken; Oya, Mototsugu; Nakashima, Jun; Marumo, Ken

    2011-01-01

    We prospectively evaluated the effect of external beam radiotherapy on erectile function in patients with localized or locally advanced prostate cancer using the Japanese version of the International Index of Erectile Function (IIEF) survey. From 2000 to 2007, we identified 55 patients who underwent external beam radiotherapy at our institution for localized or locally advanced prostate cancer and could respond to the IIEF survey. The patients did not receive neo- and/or adjuvant hormone therapy and they were followed-up for at least 12 months after radiotherapy. Mean patient age was 69 years and the mean prostate specific antigen (PSA) level before radiotherapy was 24.9 ng/ml. First we evaluated the change of the erectile function domain score over time before and after radiotherapy. The population of severe erectile dysfunction (ED) increased while those with no or mild ED decreased after radiotherapy. The erectile function and intercourse satisfaction domain score of the IIEF declined significantly after radiotherapy, however, the orgasmic function, sexual desire, and overall satisfaction domain scores did not change after external beam radiation. Of the 34 patients who had erectile function at baseline, 10 patients could maintain erectile function 12 months after radiotherapy. Though there were no significant differences in clinical features between patients who could maintain erectile function and those who had worsening erectile function 12 months after radiotherapy, the sexual desire domain score before radiotherapy was significantly higher in patients who could maintain erectile function than their counterparts. Using the IIEF survey, external beam radiation was found to affect erectile function in patients with localized or locally advanced prostate cancer. (author)

  5. Application of PIXE analysis to atmospheric environmental studies

    International Nuclear Information System (INIS)

    Kasahara, Mikio

    1997-01-01

    Physical and chemical properties of the atmospheric aerosols is a fundamental to understand the behavior of aerosols in the atmosphere. The analysis of atmospheric aerosols is the most preferable fields of the PIXE. In this paper, the characteristics of atmospheric aerosols are reviewed at first, and the sampling method of atmospheric aerosols for the PIXE samples and the characterization of atmospheric aerosols using the PIXE analysis are discussed. (author)

  6. PIXE studies of pollutants in plants

    International Nuclear Information System (INIS)

    Szymczyk, S.; Kajfosz, J.; Hrynkiewicz, A.; Curzydlo, J.

    1980-01-01

    Both industrial and road traffic pollutions were studied by PIXE by means of determination of trace elements accumulated in different plant tissues from affected areas. The method was improved by the application of an intermediate atmosphere in the target chamber. The PIXE method was proved to be adequate and convenient for monitoring many of the pollutants. (author)

  7. New results of GridPix TPCs

    International Nuclear Information System (INIS)

    Graaf, Harry van der

    2009-01-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  8. New results of GridPix TPCs

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Harry van der, E-mail: vdgraaf@nikhef.n [Science Park 105 1098 XG Amsterdam (Netherlands)

    2009-07-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  9. PIXE and {mu}-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro E-mail: zucc@ge.infn.it; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-04-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action.

  10. PIXE and μ-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    International Nuclear Information System (INIS)

    Zucchiatti, Alessandro; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-01-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action

  11. Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)

    Energy Technology Data Exchange (ETDEWEB)

    Pinsky, Lawrence S., E-mail: pinsky@uh.edu [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Empl, Anton [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Gutierrez, Andrea [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Jakubek, Jan [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Kitamura, Hisashi [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Miller, Jack [Space Sciences Laboratory, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Leroy, Claude [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Stoffle, Nicholas [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Pospisil, Stanislav [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Uchihori, Yukio; Yasuda, Nakahiro [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Zeitlin, Cary [Southwest Research Institute, 6220 Culebra Rd., San Antonio, TX 78238-5166 (United States)

    2011-05-15

    Exposures were made with Medipix2 TimePix-based Si detectors at the HIMAC facility in Japan to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken at 15 deg. increments for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. Estimates for the angular resolution for these types of tracks are also possible from these data, which are essential in the development of a TimePix-based dosimetric device for use in a space radiation environment. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si. Analysis of the images obtained shows the clear differences in the {delta}-ray halos for particles with similar dE/dx values but for differing charges and energies. These measurements are part of an ongoing program to explore the range of capabilities of the TimePix-based detector with respect to dosimetry uses in space.

  12. SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

    International Nuclear Information System (INIS)

    Kobulnicky, K; Pawlak, D; Purwar, A

    2015-01-01

    Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc

  13. SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kobulnicky, K; Pawlak, D; Purwar, A [Varian Medical Systems, Inc., Palo Alto, CA (United States)

    2015-06-15

    Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

  14. Generating AN Optimum Treatment Plan for External Beam Radiation Therapy.

    Science.gov (United States)

    Kabus, Irwin

    1990-01-01

    The application of linear programming to the generation of an optimum external beam radiation treatment plan is investigated. MPSX, an IBM linear programming software package was used. All data originated from the CAT scan of an actual patient who was treated for a pancreatic malignant tumor before this study began. An examination of several alternatives for representing the cross section of the patient showed that it was sufficient to use a set of strategically placed points in the vital organs and tumor and a grid of points spaced about one half inch apart for the healthy tissue. Optimum treatment plans were generated from objective functions representing various treatment philosophies. The optimum plans were based on allowing for 216 external radiation beams which accounted for wedges of any size. A beam reduction scheme then reduced the number of beams in the optimum plan to a number of beams small enough for implementation. Regardless of the objective function, the linear programming treatment plan preserved about 95% of the patient's right kidney vs. 59% for the plan the hospital actually administered to the patient. The clinician, on the case, found most of the linear programming treatment plans to be superior to the hospital plan. An investigation was made, using parametric linear programming, concerning any possible benefits derived from generating treatment plans based on objective functions made up of convex combinations of two objective functions, however, this proved to have only limited value. This study also found, through dual variable analysis, that there was no benefit gained from relaxing some of the constraints on the healthy regions of the anatomy. This conclusion was supported by the clinician. Finally several schemes were found that, under certain conditions, can further reduce the number of beams in the final linear programming treatment plan.

  15. Late Bronze Age hoard studied by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Neira, P.C., E-mail: carolina.gutierrez@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Montero-Ruiz, I., E-mail: ignacio.montero@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Vilaca, R., E-mail: rvilaca@fl.uc.pt [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Bottaini, C., E-mail: keret18@yahoo.it [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Gener, M., E-mail: marc.gener@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Climent-Font, A., E-mail: acf@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Department of Applied Physics, Universidad Autonoma de Madrid, Campus Cantobalanco, E-28049 Madrid (Spain)

    2011-12-15

    The hoards of metallic objects belonging to the Late European Bronze Age can be interpreted differently depending on the type, number and composition of the artefacts. PIXE analysis has been performed in nine items from the Hoard of Freixanda in Portugal comprising four socket axes, a palstave axe, a ring, a chisel, a dagger, and a casting debris. Besides the composition of the main matrix elements, that is Cu and Sn, the amount of trace elements of interest like, As, Pb, Ni, and Ag has been determined using this ion beam technique. The high tin content alloy and the high purity of the metals from the Freixanda hoard are characteristic of the Portuguese and Spanish Late Bronze Age metallurgy, supporting the idea of a regional production.

  16. PIXE Analysis of Artificial Turf

    Science.gov (United States)

    Conlan, Skye; Chalise, Sajju; Porat, Zachary; Labrake, Scott; Vineyard, Michael

    2017-09-01

    In recent years, there has been debate regarding the use of the crumb rubber infill in artificial turf on high school and college campuses due to the potential presence of heavy metals and carcinogenic chemicals. We performed Proton-Induced X-Ray Emission (PIXE) analysis of artificial turf infill and blade samples collected from high school and college campuses around the Capital District of NYS to search for potentially toxic substances. Crumb rubber pellets were made by mixing 1g of rubber infill and 1g of epoxy. The pellets and the turf blades were bombarded with 2.2 MeV proton beams from a 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory and x-ray energy spectra were collected with an Amptek silicon drift detector. We analyzed the spectra using GUPIX software to determine the elemental concentrations of the samples. The turf infill showed significant levels of Ti, Fe, Co, Ni, Cu, Zn, Br, and Pb. The highest concentration of Br in the crumb rubber was 1500 +/-100 ppm while the highest detectable amount of Pb concentration was 110 +/-20 ppm. The artificial turf blades showed significant levels of Ti, Fe, and Zn with only the yellow blade showing concentrations of V and Bi.

  17. Suppression of beam-excited electron waves by an externally applied RF signal

    International Nuclear Information System (INIS)

    Fukumasa, Osamu; Itatani, Ryohei

    1980-11-01

    Suppression of the beam-excited electron wave in a bounded system is investigated in connection with the beam distribution function. Wave suppression has two different processes depending on whether injected beams are reflected at the other end or not. In the absence of reflected beam electrons, deformation of the beam distribution function is observed in relation to the suppression of the electron wave. However, when beam electrons are reflected, the external wave suppresses the electron wave but distribution function shows no appreciable change. These experimental results show that nonlinear behaviors of beam electrons, namely behaviors of reflected beams, are quite important for wave suppression. By using the method of partial simulation, interaction between two waves in the bounded system including nonlinear motions of beam electrons is studied numerically. Qualitative agreement between experimental and numerical results is obtained. (author)

  18. PIXE methodology of rare earth element analysis and its applications

    International Nuclear Information System (INIS)

    Ma Xinpei

    1992-01-01

    The Proton Induced X-ray Emission (PIXE) methodology of rare earth element (REEs) analysis is discussed, including the significance of REE analysis, the principle of PIXE applied to REE, selection of characteristic X-ray for Lanthanide series elements, deconvolution of highly over lapped PIXE spectrum and minimum detection limit (MDL) of REEs. Some practical applications are presented. And the specialities of PIXE analysis to the high pure REE chemicals are discussed. (author)

  19. Trace-Element Analysis by Use of PIXE Technique on Agricultural Products

    Science.gov (United States)

    Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.

    2009-10-01

    In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.

  20. An assessment of effective dose to staff in external beam radiotherapy

    International Nuclear Information System (INIS)

    Rawlings, D.J.; Nicholson, L.

    1997-01-01

    Radiation safety in external beam radiotherapy is governed by national legislation. Annual doses recorded by radiographers and others associated with external beam radiotherapy are typically much lower than the relevant dose limit. However, it is possible that larger doses might be received as a result of an accidental irradiation. In the event of a significant exposure resulting in a dose at or near a relevant dose limit, an accurate conversion has to be made from the dose meter reading to the limiting quantity. A method was devised to demonstrate ratios of effective dose to personal dose equivalent which might be anticipated in the even of an individual other than the patient being irradiated within a radiotherapy treatment room consisting of a linear accelerator. The variation of ratios obtained under different conditions is discussed. (author)

  1. Guide for External Beam Radiotherapy. Procedures 2007

    International Nuclear Information System (INIS)

    Ardiet, Jean-Michel; Bourhis, Jean; Eschwege, Francois; Gerard, Jean-Pierre; Martin, Philippe; Mazeron, Jean-Jacques; Barillot, Isabelle; Bey, Pierre; Cosset, Jean-Marc; Thomas, Olivier; Bolla, Michel; Bourguignon, Michel; Godet, Jean-Luc; Krembel, David; Valero, Marc; Bara, Christine; Beauvais-March, Helene; Derreumaux, Sylvie; Vidal, Jean-Pierre; Drouard, Jean; Sarrazin, Thierry; Lindecker-Cournil, Valerie; Robin, Sun Hee Lee; Thevenet, Nicolas; Depenweiller, Christian; Le Tallec, Philippe; Ortholan, Cecile; Aimone, Nicole; Baldeschi, Carine; Cantelli, Andree; Estivalet, Stephane; Le Prince, Cyrille; QUERO, Laurent; Costa, Andre; Gerard, Jean-Pierre; Ardiet, Jean-Michel; Bensadoun, Rene-Jean; Bourhis, Jean; Calais, Gilles; Lartigau, Eric; Ginot, Aurelie; Girard, Nicolas; Mornex, Francoise; Bolla, Michel; Chauvet, Bruno; Maingon, Philippe; Martin, Etienne; Azria, David; Gerard, Jean-Pierre; Grehange, Gilles; Hennequin, Christophe; Peiffert, Didier; Toledano, Alain; Belkacemi, Yazid; Courdi, Adel; Belliere, Aurelie; Peignaux, Karine; Mahe, Marc; Bondiau, Pierre-Yves; Kantor, Guy; Lepechoux, Cecile; Carrie, Christian; Claude, Line

    2007-01-01

    In order to optimize quality and security in the delivery of radiation treatment, the French SFRO (Societe francaise de radiotherapie oncologique) is publishing a Guide for Radiotherapy. This guide is realized according to the HAS (Haute Autorite de sante) methodology of 'structured experts consensus'. This document is made of two parts: a general description of external beam radiation therapy and chapters describing the technical procedures of the main tumors to be irradiated (24). For each procedure, a special attention is given to dose constraints in the organs at risk. This guide will be regularly updated

  2. PIXE analysis of trace and other mineral elements in Romanian dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Moldovan, Maria

    2002-01-01

    Dental composites made of silicates and oxides particles embedded in an organic polymer, show a dynamic evolution but are rather expensive. Recently, the Romanian biomaterial 'Restacril' offered a low-cost alternative. Because the durability of the composite dental fillings depends both on the main chemical composition and on the impurities that may influence the inorganic particles' properties and thus modifying the bio material clinical behaviour, the elemental analysis of the material is necessary for improving its quality. Particle-induced X-ray emission (PIXE), a sensitive method for multielemental trace detection widely used in biomedical applications, allowed us to evidence 21 mineral elements with Z > 14 in some commercial dental composites. Here we evaluate the performances of PIXE for the control of dental composites by carrying out qualitative analysis of three Romanian biomaterials. PIXE measurements on thick composite samples with a flat surface were done with 3 MeV protons at the NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector, 30 mm thick Al absorber foil and integration of beam current. Up to 21 elements with Z > 19 were detected: K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Ga, Sr, Zr, Nb, Ru, Ag, Ba, Yb, Nd, Hf, Au, As and Pb. The orders of magnitude of relative concentrations were evaluated using X-ray yields obtained for another light element thick composite target. The Romanian composites have specific and diverse compositions, containing a great number of minor and trace elements, many of whom are impurities. Use of higher purity raw materials is suggested to reduce the latter and improve the materials' quality. Refinement of X-ray yields by better matching matrixes calculations and use of concentration standards are proposed for quantitative PIXE analysis of the dental composites. (authors)

  3. The target volume concept at the recording of external beam radiotherapy

    International Nuclear Information System (INIS)

    Quast, U.; Glaeser, L.

    1981-01-01

    With the aim of complete, exact and reproducible manual recording and documentation of external beam radiotherapy a concept is proposed providing treatment planning and recording related to space and time for target volumes of different order corresponding to Ist, IInd or IIIrd part of treatment course, regarding all dose limiting organs at risk. The record consists of the dosage plan for medical treatment planning, the treatment plan for physical dose distribution planning and the treatment record of absorbed doses delivered as well as a checklist for patient and machine set-up, and labels for intended actions during treatment development. A clear arrangement of the record form in logical order was found, demanding exact specification of target(s) and beam(s) and their relation in space and time; asking for verbal and graphical description of target volumes, organs at risk, patient positioning, beam portals and dose reference points in terms of patients' anatomy; emphasizing the most important medical data by marked areas and leaving enough empty space for additional data, remarks or comments. During several years of clinical use these record forms proved to be suitable for all cases of external beam therapy, for complex situations of target volumes and treatment-scheduling, for all treatment techniques and radiation qualities and for all ways of physical treatment planning. They can be extended to automatic treatment verification, monitoring and recording as well as to the application of in-vivo-measurements of absorbed doses. (orig.) [de

  4. Elemental composition of skin tissue by PIXE and INAA analyses

    International Nuclear Information System (INIS)

    Hollands, R.; Spyrou, N.M.

    1997-01-01

    Hypertrophic scars are a particular type of scar that can form after any type of dermal injury. They are unsightly, red, elevated above normal skin level, itchy and painful. At present no-one knows why these scars form. Due to the differences between scar tissue and normal skin it was decided to analyse skin tissue which at a later date would be compared to scar tissue. Spit skin graft (epidermis) samples as well as full thickness skin (epidermis to dermis) tissue were analysed using PIXE and RBS with a 2 MeV proton beam. The epidermis was compared to the dermis to see if there were any variations between the two. In all the samples P, S, Cl, K, Ca, Fe, and Cd were detected and in a majority of the samples Zn and Ba were found, using PIXE. It was found that, between the epidermis and dermis, there was an significant increase in P in the epidermis in both full thickness and split skin graft samples. Complementary elemental analysis was also performed using neutron activation, and Br, Na and Zn were detected. (author)

  5. GPU-based online track reconstruction for the MuPix-telescope

    Energy Technology Data Exchange (ETDEWEB)

    Grzesik, Carsten [JGU, Mainz (Germany); Collaboration: Mu3e-Collaboration

    2016-07-01

    The MuPix telescope is a beam telescope consisting of High Voltage Monolithic Active Pixel Sensors (HV-MAPS). This type of sensor is going to be used for the Mu3e experiment, which is aiming to measure the lepton flavor violating decay μ→ eee with an ultimate sensitivity of 10{sup -16}. This sensitivity requires a high muon decay rate in the order of 1 GHz leading to a data rate of about 1 TBit/s for the whole detector. This needs to be reduced by a factor 1000 using online event selection algorithms on Graphical Processing Units (GPUs) before passing the data to the storage. A test setup for the MuPix sensors and parts of the Mu3e tracking detector readout is realized in a four plane telescope. The telescope can also be used to show the usability of an online track reconstruction using GPUs. As a result the telescope can provide online information about efficiencies of a device under test or the alignment of the telescope itself. This talk discusses the implementation of the GPU based track reconstruction and shows some results from recent testbeam campaigns.

  6. PIXAN: the Lucas Heights PIXE analysis computer package

    International Nuclear Information System (INIS)

    Clayton, E.

    1986-11-01

    To fully utilise the multielement capability and short measurement time of PIXE it is desirable to have an automated computer evaluation of the measured spectra. Because of the complex nature of PIXE spectra, a critical step in the analysis is the data reduction, in which the areas of characteristic peaks in the spectrum are evaluated. In this package the computer program BATTY is presented for such an analysis. The second step is to determine element concentrations, knowing the characteristic peak areas in the spectrum. This requires a knowledge of the expected X-ray yield for that element in the sample. The computer program THICK provides that information for both thick and thin PIXE samples. Together, these programs form the package PIXAN used at Lucas Heights for PIXE analysis

  7. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  8. Authenticity determination of Ag-Cu Lebanese coins using combined PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Roumie, M; Nsouli, B; Assafiri, Y

    2012-01-01

    A set of silver-copper coins were investigated for their stochiometry in order to check any possible counterfeit. The studied coins are 50 Lebanese Piastres and are relatively recent, minted in 1952. They are supposed to have nominal concentration of 60 wt.% Ag and 40 wt.% Cu. In this work, it is shown the utility and capability of combining PIXE (particle induced X-ray emission) and RBS (Rutherford backscattering spectrometry) techniques to determine the elemental content and check the presence, if any, of surface layer. For this aim, 3 MeV proton beam and Al funny filter, used as x-ray absorber, were used to determine the elemental composition, based on the emission and detection of the characteristic x-rays of the corresponding elements. The first PIXE results of the supposed bulky coins showed an excess of silver composition vs. copper. In addition, the experimental protocol was checked by analyzing some other coins of known composition, such as 1-euro and 2-euro coins.

  9. Nuclear techniques for trace element analysis. PIXE and its applications to biomedical samples

    International Nuclear Information System (INIS)

    Cata-Danil, I.; Moro, R.; Gialanella, G.

    1996-01-01

    Problems in understanding the role of trace elements in the functioning of life processes are discussed. A brief review of the state of the PIXE technique is given. Principles and recent advances in beam systems, instrumentation and sample handling are covered. A rather comprehensive list of references regarding varies methodological aspects and biomedical applications is given. Some applications are discussed. In particular, preliminary results of an investigation regarding pediatric obesity are presented. (author) 5 tabs., 21 refs

  10. Use of micro-PIXE analysis for the identification of contaminants in the metal deposition on a CMS pitch adapter

    CERN Document Server

    Massi, M; Fedi, M E; Arilli, C; Grassi, N; Mando, P A; Migliori, A; Focardi, E

    2004-01-01

    In the silicon tracker for the Compact Muon Solenoid experiment at the forthcoming Large Hadron Collider of CERN, each silicon sensor is connected to the front-end electronics by a pitch adapter, the structure of which consists of a fan of very thin chromium strips coated with a few microns aluminium deposition, on a glass support. The absence of contaminants in the depositions is of crucial importance for the electrical and mechanical reliability of the micro-bonding connections. The PIXE set-up of the Florence external micro-beam facility appeared to be suitable to analyse the metal deposition of an adapter, on which the micro-bonds had shown mechanical and electrical problems. Our measurements pointed out a significant copper contamination of the metal deposition on the faulty adapter, while no copper was detected in another one, which showed a correct behaviour at bonding. This suggests a possible role of Cu impurities in the encountered problems during micro-bonding.

  11. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Makanju, O.V. [Drug Research and Production Unit, Faculty of Pharmacy, Obafemi Awolowo University (O.A.U.), Ile-Ife (Nigeria); Haque, A.M.I. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Buoso, M.C. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy); Cherubini, R. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy)

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the {sup 19}F(p,p`{gamma}){sup 19}F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.).

  12. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Haque, A.M.I.; Cherubini, R.

    1996-01-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19 F(p,p'γ) 19 F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.)

  13. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Science.gov (United States)

    Olabanji, S. O.; Makanju, O. V.; Haque, A. M. I.; Buoso, M. C.; Ceccato, D.; Cherubini, R.; Moschini, G.

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19F(p, p'γ) 19F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed.

  14. PIXE application to the study of atmospheric aerosol

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1998-11-01

    In order to confirm the measurement accuracy of PIXE (Particle Induced X-ray Emission), cross-check test were carried out between three laboratories. Thirty single element samples and one plural elements sample were used in the test. The agreements between three laboratories were evaluated to be better than 10% for the most of tested samples. The reproducibility test showed very good agreement and the dispersion in three times repeated PIXE measurements was within 6% on average. Using an automatic time sequence step sampler in Beijing collected atmospheric aerosol samples. Element concentrations were analyzed by PIXE technique. Then the data were analyzed by the absolute principal factor analysis (APFA) to evaluate the principal components and the percent variance explained by them. As a result, it shows that the PIXE analysis combed with statistical method can effectively resolve the aerosol components in urban area and distinguish between local and remote area aerosol components. The atmospheric aerosol samples were collected at four representative sites with an 8-stage cascade impactor sampler and analyzed for their elemental mass concentrations by PIXE analytic method. Based on some indicator elements, the characteristics of size distributions of particles from different sources were obtained

  15. 3D FE Analysis of RC Beams Externally Strengthened with SRG/SRP Systems

    Directory of Open Access Journals (Sweden)

    Francesco Bencardino

    2016-05-01

    Full Text Available The purpose of this study is to evaluate, through a nonlinear Finite Element (FE analysis, the structural behavior of Reinforced Concrete (RC beams externally strengthened by using Steel Reinforced Grout (SRG and Steel Reinforced Polymer (SRP systems. The parameters taken into account were the external strengthening configuration, with or without U-wrap end anchorages, as well as the strengthening materials. The numerical simulations were carried out by using a three-dimensional (3D FE model. The linear and nonlinear behavior of all materials was modeled by appropriate constitutive laws and the connection between concrete substrate and external reinforcing layer was simulated by means of cohesive surfaces with appropriate bond-slip laws. In order to overcome convergence difficulties, to simulate the quasi-static response of the strengthened RC beams, a dynamic approach was adopted. The numerical results in terms of load-displacement curves, failure modes, and load and strain values at critical stages were validated against some experimental data. As a result, the proposed 3D FE model can be used to predict the structural behavior up to ultimate stage of similar strengthened beams without carrying out experimental tests.

  16. MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

    International Nuclear Information System (INIS)

    Sutlief, S.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  17. Teeth characterization using ion beam analysis

    International Nuclear Information System (INIS)

    Rizzutto, M.A.; Added, N.; Tabacniks, M.H.; Falla-Sotelo, F.; Curado, J.F.; Francci, C.; Markarian, R.A.; Quinelato, A.; Youssef, F.; Mori, M.; Youssef, M.

    2006-01-01

    A collaboration project between the School of Dentistry and the Institute of Physics of the University of Sao Paulo has been established to measure elemental concentrations in teeth by proton induced X-ray emission (PIXE) and heavy ion elastic recoil detection analysis (HI-ERDA) techniques. Data on trace elements in human, bovine and swine teeth, analyzed by PIXE with a 2.4 MeV proton beam, were compared and concentrations for several elements were obtained with tens of μg/g sensitivity. HI-ERDA measurements employing a 52 MeV Cl beam were done to evaluate changes in elementary concentration in dental enamel after bleaching treatment with different products in 25 bovine incisors teeth. This nondestructive technique allowed the measurements of Ca, P, O and C concentrations above the limit of 100 μg/g. (author)

  18. In-vivo dosimetric study of carcinoma of uterine cervix with FBX solution in external beam therapy

    International Nuclear Information System (INIS)

    Srinivas, Challapalli; Shenoy, K. Kamalaksh; Dinesh, M.; Savitha, K.S.; Kasturi, Dinesh Pai; Supe, S.S.; Nagesha, Y.N.

    1999-01-01

    To ensure accurate dose delivery to target site in external beam therapy and brachytherapy, various authors have conducted tests to assess the process of manual dose calculations. In vivo dosimetric measurement is one of these methods to verify these calculations. In this study, an attempt has been made to compare the manually calculated dose to dose estimated using a chemical dosimeter (FBX) solution (in-vivo method, using polypropylene vials), on 12 patients of carcinoma of uterine cervix in external beam therapy. Dose measured by FBX vial varies in the range of ± 2 to 6.75%, as compared with manual calculations. These variations seen may be attributed to the location of the vial position in the vagina, with reference to the beam axis (may not be horizontal), off axis position, manual calculation variations and reproducibility of the FBX system etc. FBX dosimetry offers itself as an in-vivo method to estimate the dose delivered to the target site in external beam therapy. (author)

  19. GridPix application to dual phase TPC

    NARCIS (Netherlands)

    Alfonsi, M.; van Bakel, N.; Colijn, A.-P.; Decowski, M.P.; van der Graaf, H.; Schön, R.; Tiseni, A.

    2013-01-01

    GridPix is a gas-filled detector with an aluminium mesh stretched 50 μm above the Timepix CMOS pixel chip. This defines a high electric field where gas amplification occurs. A feasibility study is ongoing at Nikhef for the application of the GridPix technology as a charge sensitive device in a dual

  20. Evaluation of GafChromic EBT prototype B for external beam dose verification

    International Nuclear Information System (INIS)

    Todorovic, M.; Fischer, M.; Cremers, F.; Thom, E.; Schmidt, R.

    2006-01-01

    The capability of the new GafChromic EBT prototype B for external beam dose verification is investigated in this paper. First the general characteristics of this film (dose response, postirradiation coloration, influence of calibration field size) were derived using a flat-bed scanner. In the dose range from 0.1 to 8 Gy, the sensitivity of the EBT prototype B film is ten times higher than the response of the GafChromic HS, which so far was the GafChromic film with the highest sensitivity. Compared with the Kodak EDR2 film, the response of the EBT is higher by a factor of 3 in the dose range from 0.1 to 8 Gy. The GafChromic EBT almost does not show a temporal growth of the optical density and there is no influence of the chosen calibration field size on the dose response curve obtained from this data. A MatLab program was written to evaluate the two-dimensional dose distributions from treatment planning systems and GafChromic EBT film measurements. Verification of external beam therapy (SRT, IMRT) using the above-mentioned approach resulted in very small differences between the planned and the applied dose. The GafChromic EBT prototype B together with the flat-bed scanner and MatLab is a successful approach for making the advantages of the GafChromic films applicable for verification of external beam therapy

  1. A TCP model for external beam treatment of intermediate-risk prostate cancer.

    LENUS (Irish Health Repository)

    Walsh, Seán

    2013-03-01

    Biological models offer the ability to predict clinical outcomes. The authors describe a model to predict the clinical response of intermediate-risk prostate cancer to external beam radiotherapy for a variety of fractionation regimes.

  2. Determination of wear metals in engine oil by PIXE and RBS technique

    Energy Technology Data Exchange (ETDEWEB)

    Alkofahi, M M [Physics Dept., Yarmouk university, Irbid, (Jordan)

    1995-10-01

    The constituents of fresh and used engine oil were determined by PIXE and RBS techniques using 2 MeV He{sup ++} ion beams. The concentration of generated wear metals in used engine oil was measured as a function of running kilometers. The fresh oil was found to contain the elements: Si, P, S, Cl, K, Ca, and Fe. In addition to theses elements, Pb and Br were found in the used oil. Changes in the concentrations of S, Zn and Br were noticed as the running kilometers increased. 6 figs., 2 tabs.

  3. PIXE determination of Pb in wine

    International Nuclear Information System (INIS)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z.

    2002-01-01

    The permissible level of the Pb content in wine varies in the range of 200-300 μg/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 μl aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured

  4. PIXE determination of Pb in wine

    Energy Technology Data Exchange (ETDEWEB)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z. E-mail: sznagy@rmki.kfki.hu

    2002-04-01

    The permissible level of the Pb content in wine varies in the range of 200-300 {mu}g/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 {mu}l aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured.

  5. Grazing-incident PIXE Analysis Technology

    International Nuclear Information System (INIS)

    Li Hongri; Wang Guangpu; Liang Kun; Yang Ru; Han Dejun

    2009-01-01

    In the article, the grazing incidence technology is first applied to the PIXE (proton induced X-ray emission) analysis. Three pieces of samples were investigated, including the contaminated aluminium substrate, the SIMOX (separated by oxygen implantation) SOI (Silicon on Insulator) sample and the silicon wafer implanted with Fe + . The results reveal that the grazing-incident proton can improve the sensitivity of PIXE in trace analysis, especially for samples contaminated on surface. With the penetration depth of the proton bean decreased, the ratio of the peak area to the detection limit raised observably and the sensitivity near the sample surface increased. (authors)

  6. Assembling of a low energy ion beam analysis facility and use of Nuclear Microprobe techniques in geological studies

    International Nuclear Information System (INIS)

    Utui, R.

    1996-11-01

    In this work, both PIXE and ion beam induced luminescence, or just Ionoluminescence (IL) were used for geochemical studies. The possibility of rapid absolute quantification of elements in the ppm level by PIXE combined with the yet higher sensitivity of IL to transition metals and Rare Earth Elements (REE) activators, in the absence of quenching phenomena, allow for a synergic use of the two methods in geological applications with enhanced sensitivity. IL and PIXE were combined for studying REE distribution in apatite minerals and ion beam induced damage in inorganic material in general with emphasis to synthetically grown zircon crystals doped with REE. Due to the sensitivity of IL to changes in chemical bonding in the material, beam damage effects can be studied even at low integrated doses, through wavelength shift or fading of the induced light. Micro PIXE technique was used for studying profile concentrations of trace elements in pyrite grains and of elements used as geothermometers. Geothermometry allowed to assess the cooling rates in iron meteorites and the mineralization conditions in metamorphic rocks, attempting to describe the tectonic history of the terranes, with application in petrologic studies and geological prospecting. 148 refs

  7. Assembling of a low energy ion beam analysis facility and use of Nuclear Microprobe techniques in geological studies

    Energy Technology Data Exchange (ETDEWEB)

    Utui, R

    1996-11-01

    In this work, both PIXE and ion beam induced luminescence, or just Ionoluminescence (IL) were used for geochemical studies. The possibility of rapid absolute quantification of elements in the ppm level by PIXE combined with the yet higher sensitivity of IL to transition metals and Rare Earth Elements (REE) activators, in the absence of quenching phenomena, allow for a synergic use of the two methods in geological applications with enhanced sensitivity. IL and PIXE were combined for studying REE distribution in apatite minerals and ion beam induced damage in inorganic material in general with emphasis to synthetically grown zircon crystals doped with REE. Due to the sensitivity of IL to changes in chemical bonding in the material, beam damage effects can be studied even at low integrated doses, through wavelength shift or fading of the induced light. Micro PIXE technique was used for studying profile concentrations of trace elements in pyrite grains and of elements used as geothermometers. Geothermometry allowed to assess the cooling rates in iron meteorites and the mineralization conditions in metamorphic rocks, attempting to describe the tectonic history of the terranes, with application in petrologic studies and geological prospecting. 148 refs.

  8. External beam radiotherapy alone in advanced esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sung Ja; Chung, Woong Ki; Nah, Byung Sik; Nam, Taek Keun [College of Medicine, Chonnam National Univ., Kwangju (Korea, Republic of)

    1999-09-01

    We performed the retrospective analysis to find the outcome of external beam radiotherapy alone in advanced esophageal cancer patients. One hundred and six patients treated with external beam radiotherapy alone between July 1990 and December 1996 were analyzed retrospectively. We limited the site of the lesions to the thoracic esophagus and cell type to the squamous cell carcinoma. Follow-up was completed in 100 patients (94%) and ranged from 1 month to 92 months (median; 6 months). The median age was 62 years old and male to female ratio was 104:2. Fifty-three percent was the middle thorax lesion and curative radiotherapy was performed in 83%. Mean tumor dose delivered with curative aim was 58.6 Gy (55-70.8 Gy) and median duration of the radiation therapy was days. The median survival of all patients was 6 months and 1-year and 2-year overall survival rate was 27% and 12%, respectively. Improvement of dysphagia was obtained in most patients except for 7 patients who underwent feeding gastrostomy. The complete response rate immediately after radiation therapy was 32% (34/106). The median survival and 2-year survival rate of the complete responder was 14 months and 30% respectively, while those of the nonresponder was 4 months and 0% respectively (p=0.000). The median survival and 2-year survival rate of the patients who could tolerate regular diet was 9 months and 16% while those of the patients who could not tolerate regular diet was 3 months and 0%, respectively (p=0.004). The survival difference between the patients with 5 cm or less tumor length and those with more than 5 cm tumor length was marginally statistically significant (p=0.06). However, the survival difference according to the periesophageal invasion or mediastinal lymphadenopathy in the chest CT imaging study was not statistically significant in this study. In a multivariate analysis, the statistically significant covariates to the survival were complete response to radiotherapy, tumor, length, and

  9. PIXE - a new method for elemental analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1983-01-01

    With elemental analysis we mean the determination of which chemical elements are present in a sample and of their concentration. This is an old and important problem in chemistry. The earliest methods were purely chemical and many such methods are still used. However, various methods based on physical principles have gradually become more and more important. One such method is neutron activation. When the sample is bombarded with neutrons it becomes radioactive and the various radioactive isotopes produced can be identified by the radiation they emit. From the measured intensity of the radiation one can calculate how much of a certain element that is present in the sample. Another possibility is to study the light emitted when the sample is excited in various ways. A spectroscopic investigation of the light can identify the chemical elements and allows also a determination of their concentration in the sample. In the same way, if a sample can be brought to emit X-rays, this radiation is also characteristic for the elements present and can be used to determine the elemental concentration. One such X-ray method which has been developed recently is PIXE. The name is an acronym for Particle Induced X-ray Emission and indicates the principle of the method. Particles in this context means heavy, charged particles such as protons and a-particles of rather high energy. Hence, in PIXE-analysis the sample is irradiated in the beam of an accelerator and the emitted X-rays are studied. (author)

  10. Influence of boost technique (external beam radiotherapy or brachytherapy) on the outcome of patients with carcinoma of the base of the tongue

    International Nuclear Information System (INIS)

    Regueiro, C.A.; Millan, I.; Torre, A. de la; Valcarcel, F.J.; Magallon, R.; Fernandez, E.; Aragon, G.

    1995-01-01

    We reviewed 90 patients with squamous cell carcinoma of the base of the tongue. Fifty-three patients were treated with external beam radiotherapy alone (3 T1, 11 T2, 21 T3, and 18 T4 tumors) and thirty-seven patients were treated with external beam radiotherapy plus brachytherapy boost (4 T1, 15 T2, 11 T3, and 7 T4 tumors). For patients with T1, T2 and T3 primaries, the actuarial 3-year local relapse-free survival was 42% following external beam radiotherapy alone and 67% following external beam radiotherapy plus brachytherapy (p<0.05). The actuarial 3-year cause specific survival for these T-stages was 37% for patients treated with external beam radiotherapy alone and 53% for patients treated with external beam radiotherapy plus brachytherapy (p=0.1). In the Cox multivariate analyses restricted patients with T1, T2 and T3 staged tumors, treatment modality was the only predictor for local control but no influence on specific survival was found. The trend towards significant differences in specific survival found in the univariate comparison of both treatment modalities was probably due to the significantly higher number of N-positive patients treated with external beam radiotherapy alone. When all stages were included in the Cox analysis, low hemoglobin level, invasion of deep muscle, number of palpable nodes, and history of weight loss significantly influenced the outcome. Soft tissue necrosis occurred more frequently in patients treated with external beam radiotherapy plus brachytherapy (33% vs. 10%, p=0.52). (orig.)

  11. Target volume delineation in external beam partial breast irradiation: less inter-observer variation with preoperative- compared to postoperative delineation

    NARCIS (Netherlands)

    Leij, F. van der; Elkhuizen, P.H.M.; Janssen, T.M.; Poortmans, P.M.P.; Sangen, M. van der; Scholten, A.N.; Vliet-Vroegindeweij, C. van; Boersma, L.J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of

  12. Intercomparison of PIXE spectrometry software packages

    International Nuclear Information System (INIS)

    2003-02-01

    During the year 2000, an exercise was organized to make a intercomparison of widely available software packages for analysis of particle induced X ray emission (PIXE) spectra. This TECDOC describes the method used in this intercomparison exercise and presents the results obtained. It also gives a general overview of the participating software packages. This includes basic information on their user interface, graphical presentation capabilities, physical phenomena taken in account, way of presenting results, etc. No recommendation for a particular software package or method for spectrum analysis is given. It is intended that the readers reach their own conclusions and make their own choices, according to their specific needs. This TECDOC will be useful to anyone involved in PIXE spectrum analysis. This TECDOC includes a companion CD with the complete set of test spectra used for intercomparison. The test spectra on this CD can be used to test any PIXE spectral analysis software package

  13. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    International Nuclear Information System (INIS)

    Ivošević, Tatjana; Orlić, Ivica; Radović, Iva Bogdanović

    2015-01-01

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  14. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia); Orlić, Ivica [Department of Physics, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka (Croatia); Radović, Iva Bogdanović [Laboratory for Ion Beam Interaction, Ruđer Bošković Institute, Bijenička 54, HR-10000 Zagreb (Croatia)

    2015-11-15

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  15. Flexural Behavior of RC Members Using Externally Bonded Aluminum-Glass Fiber Composite Beams

    Directory of Open Access Journals (Sweden)

    Ki-Nam Hong

    2014-03-01

    Full Text Available This study concerns improvement of flexural stiffness/strength of concrete members reinforced with externally bonded, aluminum-glass fiber composite (AGC beams. An experimental program, consisting of seven reinforced concrete slabs and seven reinforced concrete beams strengthened in flexure with AGC beams, was initiated under four-point bending in order to evaluate three parameters: the cross-sectional shape of the AGC beam, the glass fiber fabric array, and the installation of fasteners. The load-deflection response, strain distribution along the longitudinal axis of the beam, and associated failure modes of the tested specimens were recorded. It was observed that the AGC beam led to an increase of the initial cracking load, yielding load of the tension steels and peak load. On the other hand, the ductility of some specimens strengthened was reduced by more than 50%. The A-type AGC beam was more efficient in slab specimens than in beam specimens and the B-type was more suitable for beam specimens than for slabs.

  16. Silicon Drift Detector response function for PIXE spectra fitting

    Science.gov (United States)

    Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.

    2018-02-01

    The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.

  17. Characterization of the lapis lazuli from the Egyptian treasure of Tôd and its alteration using external μ-PIXE and μ-IBIL

    International Nuclear Information System (INIS)

    Calligaro, T.; Coquinot, Y.; Pichon, L.; Pierrat-Bonnefois, G.; Campos, P. de; Re, A.; Angelici, D.

    2014-01-01

    Lapis lazuli is among the earliest and most priced ornamental stone worked to produce carvings, beads and inlays as early as the 4th millennium BC. It is an heterogeneous rock composed of blue lazurite Na 3 Ca(Si 3 Al 3 O 12 )S mixed with other minerals like calcite, diopside and pyrite. The historical source of lapis lazuli in antiquity is supposedly located in Afghanistan, in the Sar-e-Sang district, while other sources are known in Tajikistan and Russia (Baïkal area). This work focuses on the lapis-lazuli of the Egyptian treasure of Tôd dated from Middle Kingdom (20th c. BC). Deposited in four copper boxes, it consists of thousands of blocks of raw lapis lazuli, minute fragments, beads and carvings stylistically dated to various periods. This discovery raises the question of the use of lapis lazuli in ancient Egypt because there is no source of lapis in this country. In addition, most of the lapis lazuli artefacts are strongly weathered. The aim of this work is to understand the alteration process and to verify if its provenance can still be determined. A few artefacts were analysed using the new external microbeam line of the AGLAE facility of the C2RMF. The mineral phases were identified and corresponding trace elements (e.g. Ti, As, Ni, Ba) were ascribed using the quantitative PIXE elemental maps collected on the entire artefacts or on cross-sections. In parallel, the IBIL spectrum recorded for each point in the image provided an additional fingerprint of the luminescent phases, notably mineral species belonging to the cancrinite group. Most alteration products appeared to derive from the oxidation of the pyrite FeS 2 . It was observed that the alteration process extends to the core of most investigated artefacts. Despite such a strong alteration state, the chemical fingerprints recorded on the studied artefacts proved to be consistent with that of lapis lazuli from historical deposit of Badakshan, Afghanistan, previously investigated using the same μ-PIXE

  18. External beam monitoring of the Cyclone 30 cyclotron of IPEN-CNEN-SP

    International Nuclear Information System (INIS)

    Matsuda, Hylton

    2002-01-01

    Due to the increasing demand for cyclotron radioisotopes and the high cost of equipment and materials involved in the process, it becomes evident the importance of external beam monitoring of the cyclotron. In this way, the beam of the Cyclone 30 cyclotron of IPEN-CNEN/S P was characterized throughout the evaluation of its current intensity, profile (position, focus and geometry), alignment and homogeneity, by measuring currents, temperatures and pressures of irradiation systems. For this purpose, techniques and conventional devices, thermocouples and pressure sensors associated to electronic of instrumentation, and technology and flexibility of micro controllers allowed observing the beam behavior during irradiations in real time. The ion beam energy was also evaluated using activation analysis technique of monitor reactions in nat Cu. The beam monitoring systems have been contributing to prevent material damages and they have already been used in routine irradiations, bringing important advantages in the process of beam optimization of the Cyclone 30. (author)

  19. PIXE macro and microprobe techniques in archaeometry

    International Nuclear Information System (INIS)

    Brissaud, I.; Lagarde, G.; Houdayer, A.

    1987-01-01

    PIXE analysis method is applied to archaeometry problems. Advantages and disadvantages are emphasized. Some examples are presented which show the difficulties: especially important heterogeneities of ceramics, old coins and metals restrain from the use of this technique. Other analysis systems, less expensive, like electron microbrobe or x-ray fluorescence spectrometry, are compared with conventional PIXE method. The importance of proton microprobe is explained. (author) 40 refs.; 7 figs.; 5 tabs

  20. Radiotherapy in poor risk patients with stage I cancer of the endometrium: results of not giving external beam radiotherapy.

    Science.gov (United States)

    DeCruze, B; Guthrie, D

    1999-01-01

    Poor prognosis (poorly differentiated and/or deep myometrial invasion) Stage I endometrial cancer can have a relapse rate as high as 50%. Traditionally, most clinical oncologists treat these patients with external beam radiotherapy after surgery but there is no evidence to show that this improves survival. The retrospective study looks at the results of not giving external beam radiotherapy in 25 consecutive patients and compares the results with a group of 13 consecutive patients who did have such treatment. The two groups were comparable with regard to age, degree of differentiation and degree of invasion. Survival was comparable in the two groups. There is no evidence of any obvious decrease in survival from withholding external beam radiotherapy, but this was not a prospective randomized controlled trial. This study illustrates that it is essential that the Medical Research Council ASTEC trial should be supported because this will determine the true place of external beam radiotherapy in such patients.

  1. Development of an external beam nuclear microprobe on the Aglae facility of the Louvre museum

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. E-mail: dran@culture.fr; Ioannidou, E.; Moignard, B.; Pichon, L.; Salomon, J

    2000-03-01

    The external beam line of our facility has been recently equipped with the focusing system previously mounted on a classical nuclear microprobe. When using a 0.1 {mu}m thick Si{sub 3}N{sub 4} foil for the exit window and flowing helium on the sample under analysis, a beam spot as small as 10 {mu}m is attainable at a distance of 3 mm from the window. Elemental micromapping is performed by mechanical scanning. An electronic device has been designed which allows XY scanning by moving the sample under the beam by steps down to 0.1 {mu}m. Beam monitoring is carried out by means of the weak X-ray signal emitted by the exit foil and detected by a specially designed Si(Li) detector cooled by Peltier effect. The characteristics of external beams of protons and alpha particles are evaluated by means of resonance scanning and elemental mapping of a grid. An example of application is presented, dealing with elemental micro-mapping of inclusions in gemstones.

  2. Present role of PIXE in atmospheric aerosol research

    Energy Technology Data Exchange (ETDEWEB)

    Maenhaut, Willy, E-mail: Willy.Maenhaut@UGent.be

    2015-11-15

    In the 1980s and 1990s nearly half of the elemental analyses of atmospheric aerosol samples were performed by PIXE. Since then, other techniques for elemental analysis became available and there has been a steady increase in studies on organic aerosol constituents and other aspects of aerosols, especially in the areas of nucleation (new particle formation), optical properties, and the role of aerosol particles in cloud formation and properties. First, a brief overview and discussion is given of the developments and trends in atmospheric aerosol analysis and research of the past three decades. Subsequently, it is indicated that there is still invaluable work to be done by PIXE in atmospheric aerosol research, especially if one teams up with other aerosol researchers and performs complementary measurements, e.g., on small aerosol samples that are taken with high-time resolution. Fine examples of such research are the work done by the Lund group in the CARIBIC aircraft studies and the analysis of circular streaker samples by the Florence PIXE group. These and other examples are presented and other possibilities of PIXE are indicated.

  3. Target volume delineation in external beam partial breast irradiation: Less inter-observer variation with preoperative- compared to postoperative delineation

    International Nuclear Information System (INIS)

    Leij, Femke van der; Elkhuizen, Paula H.M.; Janssen, Tomas M.; Poortmans, Philip; Sangen, Maurice van der; Scholten, Astrid N.; Vliet-Vroegindeweij, Corine van; Boersma, Liesbeth J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of twenty-four breast cancer patients

  4. Elemental PIXE analysis of oolong tea

    International Nuclear Information System (INIS)

    Watanabe, M.; Ishii, K.; Matsuyama, S.

    2008-01-01

    The contamination of heavy metals in food becomes a serious problem. We analyzed oolong tea from different production areas by PIXE using very simple sample preparation and examined trace elements contained in these samples. From the results of this experiment, we could know oolong tea which analyzed in this experiment contains various minerals such as K, Ca, P, S, Cl, Fe, Mn, Cu and Cr but not toxic element of As which detection limit of PIXE was lower than the standard values given by the food hygiene law in Japan. (author)

  5. PIXE analysis of vehicle exhaust particulate

    International Nuclear Information System (INIS)

    Shi Xianfeng; Yao Huiying; Liu Bo; Sun Minde; Xu Huawei; Mi Yong; Shen Hao

    2001-01-01

    PIXE technique on the analysis of vehicle exhaust particulate is introduced. The clement composition and concentration of particulate are obtained. Some elements which are related to environmental pollution such as sulfur lead, silicon and manganese, were analyzed and discussed in detail by PIXE technique Nowadays although unleaded gasoline is widely used, the lead concentration is still very high in exhaust particulate. The concentrations of silicon and manganese in exhaust particulate from different model vehicles are also quite high from measurements. It shows that an evidence for exhaust pollution control could be provided from this work

  6. Distortion of optical feedback signals in microchip Nd:YAG lasers subjected to external multi-beam interference feedback

    International Nuclear Information System (INIS)

    Yi-Dong, Tan; Shu-Lian, Zhang; Zhou, Ren; Cheng, Ren; Yi-Nan, Zhang

    2010-01-01

    This paper proposes a theoretical analysis for the characteristics of an external cavity Nd:YAG laser with feedback of multiple-beam interference, which is induced by the multi-reentrance of the light from the external Fabry–Perot cavity. The theoretical model considers the multiple beam interference of the external Fabry–Perot cavity. It is found that the optical feedback signals are distorted to pulse waveforms instead of the sinusoidal ones in conventional feedback. The experimental results are in good agreement with the theoretical analysis. The obtained theoretical and experimental results can advance the development of a laser feedback interferometer

  7. The LLNL Multi-User Tandem Laboratory PIXE microprobe

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Bench, G.S.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.

    1992-01-01

    We have recently completed the construction of a new ion beamline primarily for particle-induced x-ray emission (PIXE) analysis. This will supplement our current ion microtomography (IMT) material characterization capabilities using accelerator microanalysis. In this paper we describe the PIXE beamline and give some results that characterize the system. We also report the results of some initial experiments

  8. External Beam Radiotherapy for Carcinoma of the Extrahepatic Biliary System

    International Nuclear Information System (INIS)

    Chun, Ha Chung; Lee, Myung Za

    1996-01-01

    Purpose : To evaluate the effectiveness and tolerance of patients of external beam radiotherapy of carcinoma of the extrahepatic biliary system (EHBS) including gall bladder (GB) and extrahepatic bile ducts (EHBD) and to define the role of radiotherapy for these tumors. Methods and Materials : We retrospectively analyzed the records of 43 patients with carcinoma of the EHBS treated with external beam radiotherapy at our institution between April, 1986 and July, 1994. Twenty three patients had GB cancers and remaining 20 patients did EHBD cancers. Of those 23 GB cancers, 2 had Stage II, 12 did Stage III and 9 did Stage IV disease, respectively. Male to female ratio was 11 to 12. Fifteen patients underwent radical surgery with curative intent and 8 patients did biopsy and bypass surgery alone. Postoperatively 16 patients were irradiated with 4500 cGy or higher doses and 4 patients with 3180 to 4140 cGy. Follow up periods ranged from 8 to 34 months. Results : overall median survival time of patients with GB cancer was 11 months. Median survival time for patients with Stage III and IV disease were 14 months and 5 months, respectively. Corresponding two year survival rates were 36%(4/11) and 13%(1/8), respectively. Those who underwent surgery with curative intent showed significantly better survival at 12 months than those who underwent bypass surgery alone(67% vs 13%). None of the patients died of treatment related complications. Median survival time for entire group of 20 EHBD patients was 10 months. Median survivals of 10 Stage III and 7 Stage IV disease were 10 and 8 months, respectively. Two patients who underwent Whipple's procedure had 11 and 14 month survival and those treated with resection and drainage showed median survival of 10 month. Conclusion : Postoperative external beam radiotherapy for carcinoma of the extrahepatic billary system is well tolerated and might improve survival of patients. especially those with respectable lesions with microscopic or

  9. Trace element analysis of mineral water samples by PIXE and ICP-MS

    International Nuclear Information System (INIS)

    Kennedy, V.John; Augusthy, A.; Varier, K. M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.

    1998-01-01

    Trace elements present in bottled mineral water have been studied by PIXE and ICP-MS. Samples from ten different brands of brands of bottled mineral water were prepared by preconcentration techniques. Measurements were carried out using the 2 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at the Institute of Physics, Bhubaneswar. Our results are compared with Indian standard packaged natural mineral water specifications, World Health Organisation (WHO) and European guidelines for drinking water standards. Concentration of aluminum was found to be more in one of the brands. In general, our results are comparable to the above standards. (author)

  10. Flexural behaviour of RCC beams with externally bonded FRP

    Science.gov (United States)

    Vignesh, S. Arun; Sumathi, A.; Saravana Raja Mohan, K.

    2017-07-01

    The increasing use of carbon and glass fibre reinforced polymer (FRP) sheets for strengthening existing reinforced concrete beams has generated considerable interest in understanding the behavior of the FRP sheets when subjected to bending. The study on flexure includes various parameters like percentage of increase in strength of the member due to the externally bonded Fiber reinforced polymer, examining the crack patterns, reasons of debonding of the fibre from the structure, scaling, convenience of using the fibres, cost effectiveness etc. The present work aims to study experimentally about the reasons behind the failure due to flexure of an EB-FRP concrete beam by studying the various parameters. Deflection control may become as important as flexural strength for the design of FRPreinforced concrete structures. A numerical model is created using FEM software and the results are compared with that of the experiment.

  11. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A.; Jamieson, D. N.; Prawer, S.; Allen, M.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  12. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A A; Jamieson, D N; Prawer, S; Allen, M G [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  13. Application of laser produced ion beams to nuclear analysis of materials

    International Nuclear Information System (INIS)

    Mima, K.; Fujita, K.; Azuma, H.; Yamazaki, A.; Kato, Y.; Okuda, C.; Ukyo, Y.; Sawada, H.; Gonzalez-Arrabal, R.; Perlado, J. M.; Nishimura, H.; Nakai, S.

    2013-01-01

    The ion beam driven nuclear analysis has been developed for many years by using various electrostatic accelerators. A proton micro-beam with the beam diameter of ∼1.5 μm at Takasaki Ion Acceleration for Advanced Radiation Application (TIARA), JAEA was used to analyze the positive electrode of the Li-ion battery with PIGE and PIXE. WThe PIGE and PIXE images of Li and Ni respectively for Li x Ni 0.8 Co 0.15 Al 0.05 O 2 (x = 0.75 ∼ 1.0) anodes have been taken. The PIGE images of Li x Ni 0.8 Co 0.15 Al 0.05 O 2 particles and the depth profile of the Li density have been obtained with high spatial resolution (a few μm). The images of the Li density distribution are very useful for the RandD of the Li ion battery. In order to make the in-situ ion beam analysis of the Li battery possible, a compact accelerator for a high quality MeV proton beam is necessary. Form this point of view, the diagnostics of Li ion battery is an appropriate field for the applications of laser produced ion beams. (authors)

  14. PIXE analysis by baby cyclotron

    International Nuclear Information System (INIS)

    Yoshida, Hyogo; Tanaka, Teruaki; Ito, Takashi; Toda, Yohjiro; Wakasa, Hideichiro

    1988-01-01

    The Japan Steel Works, Ltd. has been supplying a very small sized cyclotron (Baby Cyclotron) to hospitals and research facilities. The cyclotron is designed to produce short-lived radioisotopes for medical use. In the present study, this cyclotron is modified so that it can serve for PIXE analysis. The PIXE (particle induced X-ray emission) technique has the following features: (1) Down to 1 ng of trace material in a sample (mg - μg) can be detected, (2) An analysis run is completed in one to ten minutes, permitting economical analysis for a large number of samples, (3) Several elements can be analyzed simultaneously, with an almost constant sensitivity for a variety of elements ranging from aluminum to heavy metals, (4) Analysis can be performed nondestructively without a chemical process, and (5) The use of microbeam can provide data on the distribution of elements with a resolution of several μm. Software for analysis is developed to allow the modified equipment to perform peak search, background fitting, and identification and determination of peaks. A study is now being conducted to examine the performance of the equipment for PIXE analysis of thin samples. Satisfactory results have been obtained. The analysis time, excluding the background correction, is 5-10 min. (Nogami, K.)

  15. Unriddling of ancient-medieval culture by PIXE

    International Nuclear Information System (INIS)

    Uda, M.

    1997-01-01

    Some examples are given for unriddling of ancient-medieval culture by PIXE. Effectiveness of PIXE to analyze art and archaeological objects is also explained. Objects employed here are 1) red, yellow, blue and white pigments painted on sun-dried bricks excavated in Egypt, 2) ancient glass beads used in the Near East, 3) South American mummy hair, 4) ancient slag excavated from Kansai-district, Japan 5) ink used by Galileo Galilei and 6) Renaissance style enameled gold jewelry. (author)

  16. The role of micro-NRA and micro-PIXE in carbon mapping of organic tissues

    International Nuclear Information System (INIS)

    Niekraszewicz, L.A.B.; Souza, C.T. de; Stori, E.M.; Jobim, P.F.C.; Amaral, L.; Dias, J.F.

    2015-01-01

    This study reports the work developed in the Ion Implantation Laboratory (Porto Alegre, RS, Brazil) in order to implement the micro-NRA technique for the study of light elements in organic tissues. In particular, the work was focused on nuclear reactions employing protons and alphas with carbon. The (p,p) resonances at 0.475 and 1.734 were investigated. The (α,α) resonance at 4.265 MeV was studied as well. The results indicate that the yields for the 0.475 and 1.734 MeV resonances are similar. Elemental maps of different structures obtained with the micro-NRA technique using the 1.734 MeV resonance were compared with those obtained with micro-PIXE employing a SDD detector equipped with an ultra-thin window. The results show that the use of micro-NRA for carbon at 1.734 MeV resonance provides good results in some cases at the expense of longer beam times. On the other hand, micro-PIXE provides enhanced yields but is limited to surface analysis since soft X-rays are greatly attenuated by matter

  17. Effect of external magnetic field on critical current for the onset of virtual cathode oscillations in relativistic electron beams

    International Nuclear Information System (INIS)

    Hramov, Alexander; Koronovskii, Alexey; Morozov, Mikhail; Mushtakov, Alexander

    2008-01-01

    In this Letter we research the space charge limiting current value at which the oscillating virtual cathode is formed in the relativistic electron beam as a function of the external magnetic field guiding the beam electrons. It is shown that the space charge limiting (critical) current decreases with growth of the external magnetic field, and that there is an optimal induction value of the magnetic field at which the critical current for the onset of virtual cathode oscillations in the electron beam is minimum. For the strong external magnetic field the space charge limiting current corresponds to the analytical relation derived under the assumption that the motion of the electron beam is one-dimensional [D.J. Sullivan, J.E. Walsh, E. Coutsias, in: V.L. Granatstein, I. Alexeff (Eds.), Virtual Cathode Oscillator (Vircator) Theory, in: High Power Microwave Sources, vol. 13, Artech House Microwave Library, 1987, Chapter 13]. Such behavior is explained by the characteristic features of the dynamics of electron space charge in the longitudinal and radial directions in the drift space at the different external magnetic fields

  18. Unified model to predict flexural shear behavior of externally bonded RC beams

    International Nuclear Information System (INIS)

    Colotti, V.; Spadea, G.; Swamy, R.N.

    2006-01-01

    Structural strengthening with externally bonded reinforcement is now recognized as a cost-effective, structurally sound and practically efficient method of rehabilitating deteriorating and damaged reinforced concrete beams. There is now an urgent need to develop a sound engineering basis which can predict the failure loads of all such strengthened beams in a reliable and consistent manner. Existing models to predict the behavior at ultimate of strengthened beams suffer from many limitations and weaknesses. This paper presents a unified global model, based on the Strut-and-Tie approach, to predict the failure loads of reinforced concrete beams strengthened for flexure and/or shear. This structural model is based on rational engineering principles, considers all the possible failure modes, and incorporates the load transfer mechanism bond to reflect the debonding phenomena which has a dominant influence on the failure process of plated beams. The model is validated against about 200 strengthened beam test reported in the literature and failing in flexure and/or shear, involving a large number of structural variables and steel, carbon and glass fiber reinforced polymer laminates as reinforcing medium. (author)

  19. External post-operational checks for the LHC beam dumping system

    International Nuclear Information System (INIS)

    Magnin, N.; Baggiolini, V.; Carlier, E.; Goddard, B.; Gorbonosov, R.; Khasbulatov, D.; Uythoven, J.; Zerlauth, M.

    2012-01-01

    The LHC Beam Dumping System (LBDS) is a critical part of the LHC machine protection system. After every LHC beam dump action the various signals and transient data recordings of the beam dumping control systems and beam instrumentation measurements are automatically analysed by the external Post-Operational Checks (XPOC) system to verify the correct execution of the dump action and the integrity of the related equipment. This software system complements the LHC machine protection hardware, and has to ascertain that the beam dumping system is 'as good as new' before the start of the next operational cycle. This is the only way by which the stringent reliability requirements can be met. The XPOC system has been developed within the framework of the LHC 'Post-Mortem' system, allowing highly dependable data acquisition, data archiving, live analysis of acquired data and replay of previously recorded events. It is composed of various analysis modules, each one dedicated to the analysis of measurements coming from specific equipment. This paper describes the global architecture of the XPOC system and gives examples of the analyses performed by some of the most important analysis modules. It explains the integration of the XPOC into the LHC control infrastructure along with its integration into the decision chain to allow proceeding with beam operation. Finally, it discusses the operational experience with the XPOC system acquired during the first years of LHC operation, and illustrates examples of internal system faults or abnormal beam dump executions which it has detected. (authors)

  20. PIXE analysis of atmospheric particulate matter in glas fibre filters

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Orsini, C.Q.; Maenhaut, W.

    1993-01-01

    A 3-step extraction procedure was developed to allow particle-induced X-ray emission (PIXE) analysis of particulate matter in normal glass fibre filter samples. The detection limits, expressed in ng/m 3 of air, for the filter extracts were 5 to 30 times lower than those achieved by PIXE analysis or ordinary Nuclepore polycarbonate filter samples. The concentration results were compared with those obtained from routine atomic absorption spectrometry measurements and with the PIXE data from Nuclepore stacked filter unit samples taken in parallel. (orig.)

  1. PIXE analysis of cave sediments, prehispanic paintings and obsidian cutting tools from Baja California Sur caves

    International Nuclear Information System (INIS)

    Miranda, J.; Oliver, A.; Dacal, A.; Ruvalcaba, J.L.; Cruz, F.; Ortiz, M.E.; Vinas, R.

    1993-01-01

    Elemental PIXE analysis of cave sediments, minerals, pigments of the prehispanic paintings and obsidian cutting tools from caves in Baja California Sur has been carried out with a 0.7 MeV proton beam. The elements analysed in this sample set (Al to Co) provide an idea of the environment of the caves. The obsidian data analysis suggests that the human communities who made these painting used more than one obsidian source to manufacture cutting tools. (orig.)

  2. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    International Nuclear Information System (INIS)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V.

    2009-01-01

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  3. Non-destructive analysis and identification of jade by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Zhang, B.; Yang, F.J.

    2004-01-01

    This paper reports the experimental results of identifying jade by proton induced X-ray emission (PIXE) technique. It is found that the jade can be classified, according to the chemical composition determined by PIXE. The experimental results can differentiate ancient Chinese jade works of art from fakes if the material is the same

  4. Shear Strengthening of RC Deep Beam Using Externally Bonded GFRP Fabrics

    Science.gov (United States)

    Kumari, A.; Patel, S. S.; Nayak, A. N.

    2018-06-01

    This work presents the experimental investigation of RC deep beams wrapped with externally bonded Glass Fibre Reinforced Polymer (GFRP) fabrics in order to study the Load versus deflection behavior, cracking pattern, failure modes and ultimate shear strength. A total number of five deep beams have been casted, which is designed with conventional steel reinforcement as per IS: 456 (Indian standard plain and reinforced concrete—code for practice, Bureau of Indian Standards, New Delhi, 2000). The spans to depth ratio for all RC deep beams have been kept less than 2 as per the above specification. Out of five RC deep beams, one without retrofitting serves as a reference beam and the rest four have been wrapped with GFRP fabrics in multiple layers and tested with two point loading condition. The first cracking load, ultimate load and the shear contribution of GFRP to the deep beams have been observed. A critical discussion is made with respect to the enhancement of the strength, behaviour and performance of retrofitted deep beams in comparison to the deep beam without GFRP in order to explore the potential use of GFRP for strengthening the RC deep beams. Test results have demonstrated that the deep beams retrofitted with GFRP shows a slower development of the diagonal cracks and improves shear carrying capacity of the RC deep beam. A comparative study of the experimental results with the theoretical ones predicted by various researchers available in the literatures has also been presented. It is observed that the ultimate load of the beams retrofitted with GFRP fabrics increases with increase of number of GFRP layers up to a specific number of layers, i.e. 3 layers, beyond which it decreases.

  5. Propagation characteristics of a focused laser beam in a strontium barium niobate photorefractive crystal under reverse external electric field.

    Science.gov (United States)

    Guo, Q L; Liang, B L; Wang, Y; Deng, G Y; Jiang, Y H; Zhang, S H; Fu, G S; Simmonds, P J

    2014-10-01

    The propagation characteristics of a focused laser beam in a SBN:75 photorefractive crystal strongly depend on the signal-to-background intensity ratio (R=Is/Ib) under reverse external electric field. In the range 20>R>0.05, the laser beam shows enhanced self-defocusing behavior with increasing external electric field, while it shows self-focusing in the range 0.03>R>0.01. Spatial solitons are observed under a suitable reverse external electric field for R=0.025. A theoretical model is proposed to explain the experimental observations, which suggest a new type of soliton formation due to "enhancement" not "screening" of the external electrical field.

  6. PIXE studies on gold standards by protons of energy 3.3 Me V

    International Nuclear Information System (INIS)

    Joseph, Daisy; Saxena, A.; Gupta, S.K.; Kailas, S.

    2005-01-01

    Proton Induced X-ray Emission Technique (PIXE) has been used in analysing Gold standards of 22, 20, 18, and 14 karats with a proton beam of energy 3.3 MeV at the newly commissioned Folded Tandem Ion Accelerator (FOTIA). Well resolved Au and Ag X-rays were detected at a current of 3 nA. Percentage values of gold and silver were calculated and were checked with those obtained by Energy Dispersive X-ray Fluorescence Method and were found to be in agreement with the certified values as well as those obtained by XRF. (author)

  7. Strengthening of Reinforced Concrete Beam in Shear Zone by Compensation the Stirrups with Equivalent External Steel Plates

    Directory of Open Access Journals (Sweden)

    Khamail Abdul-Mahdi Mosheer

    2016-09-01

    Full Text Available An experimental study on reinforced concrete beams strengthened with external steel plates instead of shear stirrups has been held in this paper. Eight samples of the same dimensions and properties were used. Two of them were tested up to failure and specified as references beams; one with shear reinforcement and the other without shear reinforcement. Another samples without shear reinforcement were tested until the first shear crack occurs, then the samples strengthened on both sides with external steel plates as equivalent area of removed stirrups. The strengthened beams were divided into three groups according to the thickness of plates (1, 1.5, 2 mm, each group involved two beams; one bonded using epoxy and the other bonded using epoxy with anchored bolts. Finally, the strengthened beams tested when using anchored bolts with epoxy glue to bond plates. Where the increasing in maximum load is higher than that in reference beam with no internal stirrups reach to (75.46 –106.13% and has a good agreement with the control beam with shear reinforcement reach to (76.06 – 89.36% of ultimate load.

  8. Combined PIXE and XPS analysis on republican and imperial Roman coins

    International Nuclear Information System (INIS)

    Dacca, A.; Prati, P.; Zucchiatti, A.; Lucarelli, F.; Mando, P.A.; Gemme, G.; Parodi, R.; Pera, R.

    2000-01-01

    A combined PIXE and XPS analysis has been performed on a few Roman coins of the republican and imperial age. The purpose was to investigate via XPS the nature and extent of patina in order to be capable of extracting PIXE data relative to the coins bulk. The inclusion of elements from the surface layer, altered by oxidation and inclusion, is a known source of uncertainty in PIXE analyses of coins, performed to assess the composition and the provenance

  9. SU-E-J-181: Effect of Prostate Motion On Combined Brachytherapy and External Beam Dose Based On Daily Motion of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Providence Cancer Center, Southfield, MI (United States); University of Michigan, Ann Arbor, MI (United States); Ealbaj, J [University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients were set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.

  10. The effect of combined external beam and high-dose intracavitary brachytherapy on dysphagia and survival in patients with advanced esophageal cancer

    International Nuclear Information System (INIS)

    Yorozu, Atsunori; Dokiya, Takushi; Ogita, Mikio; Kutsuki, Shoji

    1996-01-01

    During an 11-year period, a group of 130 patients with esophageal cancer of stages 2 to 4 were treated with external beam irradiation (40 to 60 Gy) followed by boost dose of 10 to 20 Gy of high-dose intracavitary brachytherapy. The overall 2-year survival rate was 15.4%. The significant prognostic factors were tumor size, response to external beam irradiation, pretreatment dysphagia score, and presence of distant metastases. The palliative effect was excellent; the dysphagia scores of 122 of 130 patients (93.8%) improved. The significant palliative factors were response to external beam irradiation and pretreatment dysphagia score. Tracheoesophageal fistulas developed after treatment in 13 of 130 patients (10%); 3 of the fistulas were probably related to radiotherapy. We conclude that intracavitary brachytherapy is useful in the treatment of cases of advanced cancer which show a good response to external beam irradiation and may be curative in patients with mild dysphagia. (author)

  11. Interfacial stresses in damaged RC beams strengthened with externally bonded CFRP plate

    International Nuclear Information System (INIS)

    Benrahou, K.H.; Adda bedia, E.A.; Benyoucef, S.; Tounsi, A.; Benguediab, M.

    2006-01-01

    A theoretical method to predict the interfacial stresses in the adhesive layer of damaged reinforced concrete beams strengthened with externally bonded carbon fiber-reinforced polymer (CFRP) plate is presented. The adopted model is developed including the adherend shear deformations by assuming a linear shear stress through the depth of the RC beam [A. Tounsi, Int. J. Solids Struct., in press], while all existing solutions neglect this effect [e.g. S. Benyoucef, A. Tounsi, S.A. Meftah, E.A. Adda Bedia, Compos. Interfaces, in press; S.T. Smith, J.G. Teng, Eng. Struct. 23 (7) (2001) 857-871; T.M. Roberts, Struct. Eng. 67 (12) (1989) 229-233; A. Tounsi, S. Benyoucef, Int. J. Adhes. Adhes., in press; T. Stratford, J. Cadei, Construct. Building Mater. 20 (2006) 34-35]. In addition, in the present study the anisotropic damage model is adopted to describe the damage of the RC beams. It is shown that the damage has a significant effect on the interfacial stresses in FRP-damaged RC beam

  12. Micro-PIXE for the quantitative imaging of chemical elements in single cells

    International Nuclear Information System (INIS)

    Ortega, R.

    2013-01-01

    Full text: The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The aim of this seminar will be to present the recent achievements in this field using micro-PIXE analysis. The combination of micro-PIXE with RBS (Rutherford Backscattering Spectrometry) and STIM (Scanning Transmission lon Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STlM analysis will be more specifically highlighted as it provides high spatial resolution imaging (<200 nm) and excellent mass sensitivity (<0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron X-ray fluorescence or the techniques based on mass spectrometry. Examples of micro-PIXE studies for subcellular imaging of trace elements in the various fields of interest will be presented such as metal-based toxicology, pharmacology, and neuro degeneration [1] R. Ortega, G. Devés, A. Carmona. J. R. Soc. Interface, 6, (2009) S649-S658. (author)

  13. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    International Nuclear Information System (INIS)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-01-01

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape

  14. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    Energy Technology Data Exchange (ETDEWEB)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth, E-mail: rsignorell@ethz.ch [Laboratory of Physical Chemistry, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich (Switzerland)

    2015-04-21

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  15. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces.

    Science.gov (United States)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-04-21

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  16. Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces

    Science.gov (United States)

    David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth

    2015-04-01

    We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

  17. MeV ion-beam analysis of optical data storage films

    Science.gov (United States)

    Leavitt, J. A.; Mcintyre, L. C., Jr.; Lin, Z.

    1993-01-01

    Our objectives are threefold: (1) to accurately characterize optical data storage films by MeV ion-beam analysis (IBA) for ODSC collaborators; (2) to develop new and/or improved analysis techniques; and (3) to expand the capabilities of the IBA facility itself. Using H-1(+), He-4(+), and N-15(++) ion beams in the 1.5 MeV to 10 MeV energy range from a 5.5 MV Van de Graaff accelerator, film thickness (in atoms/sq cm), stoichiometry, impurity concentration profiles, and crystalline structure were determined by Rutherford backscattering (RBS), high-energy backscattering, channeling, nuclear reaction analysis (NRA) and proton induced X-ray emission (PIXE). Most of these techniques are discussed in detail in the ODSC Annual Report (February 17, 1987), p. 74. The PIXE technique is briefly discussed in the ODSC Annual Report (March 15, 1991), p. 23.

  18. Application of PIXE to study ancient Iranian silver coins

    International Nuclear Information System (INIS)

    Hajivaliei, M.; Mohammadifar, Y.; Ghiyasi, K.; Jaleh, B.; Lamehi-Rachti, M.; Oliaiy, P.

    2008-01-01

    A number of ancient Iranian silver coins belonging to Khosrau II (592-626 A.D.) minted during Sasanians dynasty were analyzed using proton induced X-ray emission (PIXE) technique. The 2 MeV proton beam with a current of 2-3 nA from AEOI, Van de Graaff accelerator was used to bombard the coins. The characteristic X-rays emitted from the samples, were detected by a Si(Li) detector from ORTEC with an energy resolution of 170 eV at 5.9 keV. The detector was placed in the beam direction at 135 deg. The elements Cl, Ca, Ti, Mn, Fe, Cu, Au and Pb were observed in the coins along with the major component silver. The percentage of silver varied between 85.87 and 93.39%. The possible correlation between the composition of coins and the minting time or the minting location of coins was the prime goal. There was a negative correlation between copper and silver. The weight of coins varied between 4.02 and 4.30 g. Going through the results, it seems that the local mines were used to die-strike the coins. The obtained results are in good agreement with archaeological records

  19. Application of PIXE to study ancient Iranian silver coins

    Energy Technology Data Exchange (ETDEWEB)

    Hajivaliei, M. [Department of Physics, Bu-Ali Sina University, Hamedan 65174 (Iran, Islamic Republic of)], E-mail: mhaji65@yahoo.com; Mohammadifar, Y. [Department of Archaeology, Bu-Ali Sina University, Hamedan 65174 (Iran, Islamic Republic of); Ghiyasi, K.; Jaleh, B. [Department of Physics, Bu-Ali Sina University, Hamedan 65174 (Iran, Islamic Republic of); Lamehi-Rachti, M.; Oliaiy, P. [Van de Graaff Laboratory, AEOI, P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2008-04-15

    A number of ancient Iranian silver coins belonging to Khosrau II (592-626 A.D.) minted during Sasanians dynasty were analyzed using proton induced X-ray emission (PIXE) technique. The 2 MeV proton beam with a current of 2-3 nA from AEOI, Van de Graaff accelerator was used to bombard the coins. The characteristic X-rays emitted from the samples, were detected by a Si(Li) detector from ORTEC with an energy resolution of 170 eV at 5.9 keV. The detector was placed in the beam direction at 135 deg. The elements Cl, Ca, Ti, Mn, Fe, Cu, Au and Pb were observed in the coins along with the major component silver. The percentage of silver varied between 85.87 and 93.39%. The possible correlation between the composition of coins and the minting time or the minting location of coins was the prime goal. There was a negative correlation between copper and silver. The weight of coins varied between 4.02 and 4.30 g. Going through the results, it seems that the local mines were used to die-strike the coins. The obtained results are in good agreement with archaeological records.

  20. Application of PIXE to study ancient Iranian silver coins

    Science.gov (United States)

    Hajivaliei, M.; Mohammadifar, Y.; Ghiyasi, K.; Jaleh, B.; Lamehi-Rachti, M.; Oliaiy, P.

    2008-04-01

    A number of ancient Iranian silver coins belonging to Khosrau II (592-626 A.D.) minted during Sasanians dynasty were analyzed using proton induced X-ray emission (PIXE) technique. The 2 MeV proton beam with a current of 2-3 nA from AEOI, Van de Graaff accelerator was used to bombard the coins. The characteristic X-rays emitted from the samples, were detected by a Si(Li) detector from ORTEC with an energy resolution of 170 eV at 5.9 keV. The detector was placed in the beam direction at 135°. The elements Cl, Ca, Ti, Mn, Fe, Cu, Au and Pb were observed in the coins along with the major component silver. The percentage of silver varied between 85.87 and 93.39%. The possible correlation between the composition of coins and the minting time or the minting location of coins was the prime goal. There was a negative correlation between copper and silver. The weight of coins varied between 4.02 and 4.30 g. Going through the results, it seems that the local mines were used to die-strike the coins. The obtained results are in good agreement with archaeological records.

  1. GIT1/βPIX signaling proteins and PAK1 kinase regulate microtubule nucleation.

    Science.gov (United States)

    Černohorská, Markéta; Sulimenko, Vadym; Hájková, Zuzana; Sulimenko, Tetyana; Sládková, Vladimíra; Vinopal, Stanislav; Dráberová, Eduarda; Dráber, Pavel

    2016-06-01

    Microtubule nucleation from γ-tubulin complexes, located at the centrosome, is an essential step in the formation of the microtubule cytoskeleton. However, the signaling mechanisms that regulate microtubule nucleation in interphase cells are largely unknown. In this study, we report that γ-tubulin is in complexes containing G protein-coupled receptor kinase-interacting protein 1 (GIT1), p21-activated kinase interacting exchange factor (βPIX), and p21 protein (Cdc42/Rac)-activated kinase 1 (PAK1) in various cell lines. Immunofluorescence microscopy revealed association of GIT1, βPIX and activated PAK1 with centrosomes. Microtubule regrowth experiments showed that depletion of βPIX stimulated microtubule nucleation, while depletion of GIT1 or PAK1 resulted in decreased nucleation in the interphase cells. These data were confirmed for GIT1 and βPIX by phenotypic rescue experiments, and counting of new microtubules emanating from centrosomes during the microtubule regrowth. The importance of PAK1 for microtubule nucleation was corroborated by the inhibition of its kinase activity with IPA-3 inhibitor. GIT1 with PAK1 thus represent positive regulators, and βPIX is a negative regulator of microtubule nucleation from the interphase centrosomes. The regulatory roles of GIT1, βPIX and PAK1 in microtubule nucleation correlated with recruitment of γ-tubulin to the centrosome. Furthermore, in vitro kinase assays showed that GIT1 and βPIX, but not γ-tubulin, serve as substrates for PAK1. Finally, direct interaction of γ-tubulin with the C-terminal domain of βPIX and the N-terminal domain of GIT1, which targets this protein to the centrosome, was determined by pull-down experiments. We propose that GIT1/βPIX signaling proteins with PAK1 kinase represent a novel regulatory mechanism of microtubule nucleation in interphase cells. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Nonlinear Analysis of External Prestressed Reinforced Concrete Beams with BFRP and CFRP

    Directory of Open Access Journals (Sweden)

    Haleem K. Hussain

    2017-05-01

    Full Text Available The traditional strengthening methods for concrete structure (girders, beams, columns…. consuming time and could be an economical, a new modern repair methods using the Carbon Fiber Reinforced Polymers (CFRP and Basalt Fiber Reinforced Polymer (BFRP as a laminate strips or bars,and considered a competitive solution that will increase the life-cycle of repaired structures. This study investigated the strengthen reinforced concrete girder. Nonlinear analysis have been adopted to the models using FEM analysis (ANSYS to simulate the theoretical results compared with experimental results.Using finite element packages, more efficient and better analyses can be made to fully understand the response of individual structural components and their contribution to a structure as a whole.Three type of material are used in this study as an external prestressed wire (steel, CFRP and BFRP. The prestressed beam is modeled as simply supported beam with two concentrated point load. The results showed that all tested strengthening beam increased the load carryingcapacity of the beams depend on prestressing force. Obtained Result was compared for different type of beam.This study also was enlarged to include using CFRP and BFRPbarwhich are light weight and moredurable, lead to ease of handling and maintenance. The research conducted analytical work to evaluate the effectiveness of concrete beams reinforced normally by the use of CFRP and BFRP bars. The results showed a significant gain in the beam’s ultimate capacities using CFRP bars comparing with beam reinforced with BFRP bar and reference beam

  3. Particulate characterization by PIXE multivariate spectral analysis

    International Nuclear Information System (INIS)

    Antolak, Arlyn J.; Morse, Daniel H.; Grant, Patrick G.; Kotula, Paul G.; Doyle, Barney L.; Richardson, Charles B.

    2007-01-01

    Obtaining particulate compositional maps from scanned PIXE (proton-induced X-ray emission) measurements is extremely difficult due to the complexity of analyzing spectroscopic data collected with low signal-to-noise at each scan point (pixel). Multivariate spectral analysis has the potential to analyze such data sets by reducing the PIXE data to a limited number of physically realizable and easily interpretable components (that include both spectral and image information). We have adapted the AXSIA (automated expert spectral image analysis) program, originally developed by Sandia National Laboratories to quantify electron-excited X-ray spectroscopy data, for this purpose. Samples consisting of particulates with known compositions and sizes were loaded onto Mylar and paper filter substrates and analyzed by scanned micro-PIXE. The data sets were processed by AXSIA and the associated principal component spectral data were quantified by converting the weighting images into concentration maps. The results indicate automated, nonbiased, multivariate statistical analysis is useful for converting very large amounts of data into a smaller, more manageable number of compositional components needed for locating individual particles-of-interest on large area collection media

  4. Determination of Hg concentration in gases by PIXE

    Science.gov (United States)

    Dutkiewicz, E.; van Kuijen, W. J. P.; Munnik, F.; Mutsaers, P. H. A.; Rokita, E.; de Voigt, M. J. A.

    1992-05-01

    A method for determination of the concentration of mercury in the gaseous phase is described. In the first step of the method a stable sulphur-mercury complex is formed. For this purpose sulphur is deposited on a filter and the investigated gas flows through the filter. Millipore filters and the deposition of sulphur from Na2S2O3 * 5H2O solution were found to be most suitable. The amount of Hg absorbed on the filter was determined by PIXE or by NAA in the second step of the method. An optimization of proton energy was performed in the PIXE analysis to obtain the maximal signal-to-background ratio. The detection limit of the method, expressed as the minimal amount of Hg which has to flow through the filter equals to 30 and 2 ng for PIXE and NAA techniques, respectively. Applications of the method are also described.

  5. PIXE analysis of otoliths from several species of teleost fish

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru; Maeda, Kuniko.

    1994-01-01

    In-air PIXE was used to analyze trace elements in otoliths from several species of teleost fish in order to examine the correlation between the trace elements concentrations and environmental conditions. Mn, Fe, Zn and Sr were detected accurately in the order of ppm by using the in-air PIXE. It seemed that concentrations of Sr and Zn in red sea bream otoliths increased in proportion to higher seawater temperature. In addition, there were significant differences in trace element composition between that of reared red sea bream and rockfish and that of wild ones. Preliminary results indicate that the PIXE is a powerful technique to investigate fish otoliths. (author)

  6. Atmospheric environment measurement 3. Environmental pollution monitoring system using PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    2009-01-01

    The PIXE(Proton Induced X-ray Emission) method is used in various fields owing to its high sensitivity. This method can be used to analyze multiple elements in a short time and therefore is suitable for the analysis of large quantities of environmental samples. We researched the effect of removing footwear in a room on indoor aerosol pollution. The concentration of aerosol particles in the case that footwear was not removed was 5 times larger than in the case when footwear was removed. We were able to identify a source of air pollution using both the results of PIXE analysis and information on wind direction. We applied PIXE analysis to investigate airborne yellow sand, which originals from the Gobi desert. By analyzing each yellow sand particle, hazardous yellow sand could be detected. We also applied PIXE analysis to river water pollution. River water samples were collected at a number of points along a river. The dilution of metallic elements by the river water was observed. Thus, it was shown that monitoring systems using the PIXE method are very useful for monitoring environmental pollution. (author)

  7. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm......High power diode lasers are used in a large number of applications. A limiting factor for more widespread use of broad area lasers is the poor beam quality. Gain guided tapered diode lasers are ideal candidates for industrial applications that demands watt level output power with good beam quality...

  8. Charge collection in an external proton beam

    International Nuclear Information System (INIS)

    Wookey, C.W.; Somswasdi, B.; Rouse, J.L.

    1982-01-01

    Results from the measurement of the stability of charge collected from the target and exit foil, or as alternatives, the γ-ray or backscattered proton counts from the exit foil and the Ar X-ray counts from the air path in an external proton beam are presented. These results show that comparative analysis of material mounted in air is reliable, using either the collected charge or the γ-ray counts as the normalizing factor, if there are no earthed objects in close geometry. The backscattered proton counts can also be used, but not the Ar X-ray counts, unless the current is stabilized. The electrical or thermal conductivity of the target and the target to exit foil separation do not affect the proportionality of the collected charge and the γ-ray counts to the charge incident on the target

  9. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  10. Application of PIXE to study ancient Iranian silver coins

    Energy Technology Data Exchange (ETDEWEB)

    Oliaiy, P.; Shokouhi, F.; Lamehi-Rachti, M.; Rahighi, J. [Van de Graaff Laboratory, AEOI, Tehran (Iran); Andami, P.; Dilmaghani, J.; Etezadi, M. [Tamashagah-e-Pool, General Office of Museums, MDFIR, Tehran (Iran)

    1999-07-01

    Ancient Iranian silver coins minted in various parts of the ancient Iran from Transoxiana to Mesopotamia over a time span of 460 years (247BC-208AD) during Parthians dynasty were analysed by PIXE with a 2.2 MeV proton beam. Forty seven silver coins owned by Tamashagah-e-Pool (museum of money) in Tehran were examined in this study. The possible correlation between the composition of coins and the minting time or the minting location of coins has been the prime objective of the present study. Elemental analysis of ancient coins could also reveal the direct relation with the political and economical situation and also with the metallurgy of the minting time. Results on the contents of principal component elements (Fe, Ni, Cu, As, Br, Ag, Sn, Sb, Ba, Au and Pb) are presented and discussed. (author)

  11. Studies of prehistoric flint tools by PIXE

    International Nuclear Information System (INIS)

    Smit, Z.

    2002-01-01

    The trace elements preserved on sharp edges of stone tools may provide some information about the worked material, which in turn may serve for the reconstruction of users way of life. Since the amount of the deposited worked material is minute, it can only be detected by sensitive fluorescence techniques, induced by electrons in the electron microscopes, or by light ions from the particle accelerators (PIXE). The trace element deposition was studied by PIXE for a set of experimental tools used for working bone and wood, and for a set of archaeological artefacts dating from the late paleolithic till neolithic period. (author)

  12. PIXE technique use for urban aerosol characterization

    International Nuclear Information System (INIS)

    Dias da Cunha, K.; Lazarra, M.; Nazare, R.A.; D'Oliveira, D.; Barros Leite, C.V.

    1996-01-01

    A cascade impactor and PIXE technique were used to estimate the air pollution in a urban area. PIXE is a multielementar method and for all elements the detection limit is about nanograms. The particle size distribution was determined using a cascade impactor with six stage. It collects the particles in the respirable and invaluable of aerosol. The samples were collected close to Planetary in Rio de Janeiro City. The results indicate that particles containing Cu, Zn, Ni, Fe, Mn, Cr, V, Ti, Ca and K. The particle was in the respirable fraction of with MMAD,2 μm. (author)

  13. Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Bellot-Gurlet, Ludovic; Poupeau, Gerard; Salomon, Joseph; Calligaro, Thomas; Moignard, Brice; Dran, Jean-Claude; Barrat, Jean-Alix; Pichon, Laurent

    2005-01-01

    Elemental composition fingerprinting by PIXE technique is very attractive for obsidian provenance studies as it may proceed in a non-destructive mode, even if a more complete elemental characterization can be obtained by ICP-MS and/or ICP-AES. Only few studies have compared results obtained by both methods for solid rock samples. In this work, elemental compositions were determined by ICP-MS/-AES for international geochemical standards and by ICP-MS/-AES and PIXE for inter-laboratory reference obsidians. In addition 49 obsidian source samples and artefacts were analysed by both ICP-MS/-AES and PIXE. Instrumental work and measurement quality control performed for obsidian chemical characterization, underline that PIXE and ICP-MS/-AES provide reproducible, accurate and comparable measurements. In some volcanic districts the limited number of elements dosed by PIXE is sufficient for the discrimination of the potential raw sources of obsidians. Therefore, PIXE can be an advantageous substitute to ICP-MS/-AES techniques for provenance studies

  14. αPIX Is a Trafficking Regulator that Balances Recycling and Degradation of the Epidermal Growth Factor Receptor.

    Directory of Open Access Journals (Sweden)

    Fanny Kortüm

    Full Text Available Endosomal sorting is an essential control mechanism for signaling through the epidermal growth factor receptor (EGFR. We report here that the guanine nucleotide exchange factor αPIX, which modulates the activity of Rho-GTPases, is a potent bimodal regulator of EGFR trafficking. αPIX interacts with the E3 ubiquitin ligase c-Cbl, an enzyme that attaches ubiquitin to EGFR, thereby labelling this tyrosine kinase receptor for lysosomal degradation. We show that EGF stimulation induces αPIX::c-Cbl complex formation. Simultaneously, αPIX and c-Cbl protein levels decrease, which depends on both αPIX binding to c-Cbl and c-Cbl ubiquitin ligase activity. Through interaction αPIX sequesters c-Cbl from EGFR and this results in reduced EGFR ubiquitination and decreased EGFR degradation upon EGF treatment. However, quantitatively more decisive for cellular EGFR distribution than impaired EGFR degradation is a strong stimulating effect of αPIX on EGFR recycling to the cell surface. This function depends on the GIT binding domain of αPIX but not on interaction with c-Cbl or αPIX exchange activity. In summary, our data demonstrate a previously unappreciated function of αPIX as a strong promoter of EGFR recycling. We suggest that the novel recycling regulator αPIX and the degradation factor c-Cbl closely cooperate in the regulation of EGFR trafficking: uncomplexed αPIX and c-Cbl mediate a positive and a negative feedback on EGFR signaling, respectively; αPIX::c-Cbl complex formation, however, results in mutual inhibition, which may reflect a stable condition in the homeostasis of EGF-induced signal flow.

  15. A phase I/II study of external beam radiation, brachytherapy and concurrent chemotherapy in localized cancer of the esophagus (RTOG 9207)

    International Nuclear Information System (INIS)

    Gaspar, L.E.; Qian, C.; Kocha, W.I.; Coia, L.R.; Herskovic, A.; Graham, M.

    1996-01-01

    Introduction: A multi-institutional, prospective study was designed to determine the feasibility and toxicity of chemotherapy, external beam irradiation and esophageal brachytherapy (EB) in a potentially curable group of patients with adenocarcinoma or squamous cell carcinoma of the esophagus. Methods: Planned treatment was 50 Gy external beam radiation (25 fractions/5 wks) followed 2 weeks later by EB (either HDR 5 Gy wks 8,9 and 10 for a total of 15 Gy or LDR 20 Gy wk 8). The protocol was later revised to delete the LDR alternative due to poor accrual and decrease the HDR dose to 10 Gy, ie 5 Gy wks 8 and 9. Chemotherapy was given wks 1,5,8 and 11 with DDP 75 mg/m2 and 5-FU 1000 mg/m2/24 hrs, 96 hour infusion. Data is available on 50 patients (46 squamous, 3 adenocarcinoma) treated on the HDR alternative (EB dose 15 Gy and 10 Gy in 40 and 10 patients, respectively. Results: Thirty-five patients (70%) were able to complete external beam, EB and at least 2 courses of chemotherapy. Estimated survival rate at 12 months is 48%. Life-threatening toxicity or death occurred in 13 (26%) and 4 (8%) patients, respectively. Treatment-related esophageal fistulas occurred in 6 patients (12%) at 0.5 to 6.2 months from the first day of brachytherapy, leading to death in 3. So far all treatment-related fistulas occurred in the 15 Gy EB group. Conclusions: Survival following this combination of chemotherapy, external beam radiation and EB does not appear to be different from survival seen following chemotherapy and external beam radiation only. Based on the high incidence of fistulas, we urge extreme caution in employing EB as a boost following concurrent chemotherapy and external beam radiation with the schema utilized in this prospective study

  16. Forensic analysis of tempered sheet glass by particle induced X-ray emission (PIXE)

    Energy Technology Data Exchange (ETDEWEB)

    Jisonna, L.J. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); DeYoung, P.A., E-mail: deyoung@hope.ed [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Ferens, J.; Hall, C.; Lunderberg, J.M.; Mears, P. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Padilla, D. [Department of Physics, San Diego State University, San Diego, CA 92182-1233 (United States); Peaslee, G.F. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Sampson, R. [Department of Physics, Columbia University, New York, NY 10027 (United States)

    2011-05-15

    Highlights: {yields} PIXE was found to give the same results for trace elements in glass as ICP. {yields} PIXE can non-destructively determine trace element concentrations in auto glass. {yields} Measured Ca, Fe, Ti, Mn, and Sr in auto glass with PIXE. -- Abstract: The elemental concentrations of five trace elements in tempered sheet glass fragments were determined using particle-induced X-ray emission (PIXE) spectrometry. The trace element concentrations for calcium, iron, manganese, strontium, and titanium are compared to those obtained by inductively-coupled plasma-atomic emission spectrometry (ICP-AES) following complete digestion by hydrofluoric acid. For these five elements, the absolute concentrations obtained by both methods are shown to agree well over a wide range of concentrations. The limits of detection for trace elements are typically lower for the ICP-AES method. However, we show that the concentrations of these five elements can be accurately measured by the PIXE method. Since PIXE is an entirely non-destructive method, there exists a niche for this technique to be used as a complement to the more sensitive ICP-AES technique in the forensic analysis of sheet glass.

  17. Influence of external beam technique and brachytherapy quality assurance on the side effects in the combined external beam- and brachytherapy treatment of local advanced prostate cancer

    International Nuclear Information System (INIS)

    Kovacs, G.; Galalae, R.; Wirth, B.; Bertermann, H.; Wilhelm, R.; Kohr, P.; Kimmig, B.

    1996-01-01

    Transrectal ultrasound(TRUS) guided HDR implantation of the prostate has been established at the Kiel University by Bertermann and Brix in 1986 and there are to date 179 (T1b-T3 No Mo) patients treated in a combined modality. The dose for the implant was 2x 15 Gy on the capsule of the prostate in 14-20 days. For local and regional lymph nodes 20 Gy external beam therapy (AP-PA pelvic portals), 20 Gy with an individual transmission block (100% for subclinical disease, 70% and 50% according to the implant dosimetry for the prostate) and 10 Gy small volume irradiation for the prostate was applied, conventional fractioned. Total dose after the therapy 70 Gy for the prostate and 50 Gy for the subclinical disease in 6-7 weeks. As a quality control method we use since 1991 in vivo dosimetry on the medial rectum wall as well as in the prostatic part of the urethra. Regular follow-up 3-118 months after therapy (median 55) with PSA, digital rectal examination, control TRUS with volumetry (after one year with biopsy) and bone scan. There were no major early side effects within the first three months. Proctitis till 1991 with a duration up to 12 months 49%, prolonging more than one year in 23 %, (total proctitis 72.6%). Dysuria in up to 12 months 30 %, long lasting 30% (total number of dysuria 60 %). Erectile dysfunction in 56 %. Because of the number of the side effects 1991 we changed the external beam technique: instead of the biaxial arch therapy the AP-PA portals, and reduced irradiated volume (from 6480 cm 3 to 5040 cm 3 ). We introduced instead of the small volume arch therapy for 10 Gy external boost the box-technique with shielding the back part of the rectum and the upper part of the bladder resulting additional volume reduction. Through the 15 Gy HDR brachytherapy dose on the prostate capsule there are up to 8 Gy on the medial rectal wall, measured by in vivo dosimetry. This dose could not be responsible for the high number of side effects (see gynecological

  18. Quantitative analysis of soluble elements in environmental waters by PIXE

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Adachi, M.; Tsuji, M.; Hattori, T.

    1999-01-01

    We have started PIXE research for environmental science at Van de Graaff accelerator facility in Tokyo Institute of Technology. Quantitative measurements of soluble fractions in river waters have been carried out using the preconcentrate method developed in Tohoku University. We reveal that this PIXE target preparation can be also applied to waste water samples. (author)

  19. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    Energy Technology Data Exchange (ETDEWEB)

    Summerhayes, G R; Gosden, C [La Trobe Univ., Bundoora, VIC (Australia); Bird, R; Hotchkis, M [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Specht, J; Torrence, R; Fullaga, R [Australian Museum, Sydney, NSW (Australia). Div. of Anthropology

    1994-12-31

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills.

  20. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    International Nuclear Information System (INIS)

    Summerhayes, G.R.; Gosden, C.; Bird, R.; Hotchkis, M.; Specht, J.; Torrence, R.; Fullaga, R.

    1993-01-01

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills

  1. Obsidian sourcing studies in Papua New Guinea using PIXE-PIGME analysis

    Energy Technology Data Exchange (ETDEWEB)

    Summerhayes, G.R.; Gosden, C. [La Trobe Univ., Bundoora, VIC (Australia); Bird, R.; Hotchkis, M. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Specht, J.; Torrence, R.; Fullaga, R. [Australian Museum, Sydney, NSW (Australia). Div. of Anthropology

    1993-12-31

    Over 100 obsidian samples were analysed using PIXE-PIGME in 1990. These samples were collected during intensive surveys of the source areas around Talasea, Garua Island, and the Mopir area in 1988, 1989 and 1990. A ratio combination of 9 elements were used to separate out groups as per previous studies: F/Na, Al/Na, K/Fe, Ca/Fe, Mn/Fe, Rb/Fe, Y/Zr, Sr/Fe and Zr/Fe. In spite of variations in major elements, the close agreement between results for minor and trace elements concentrations in artefacts and known source material indicates that the provenance of each artefact can be reliably determined. This conclusion provides important validation of the use of ion beam analysis in artefact characterisation. ills.

  2. External beam radiotherapy for rectal adenocarcinoma

    International Nuclear Information System (INIS)

    Taylor, R.E.; Kerr, G.R.; Arnott, S.J.

    1987-01-01

    A series of 243 patients with adenocarcinoma of the rectum treated with radiotherapy is presented. Radiotherapy was combined with 5-fluorouracil, or given alone. Seventy-four patients were treated with radical external beam radiotherapy for recurrent or inoperable rectal adenocarcinoma. One hundred and forty-five patients with advanced pelvic tumours or metastases were treated with palliative pelvic radiotherapy. Twenty-four patients with small-volume residual pelvic tumour or who were felt to be at high risk of pelvic recurrence following radical resection received postoperative radiotherapy. Complete tumour regression was seen in 38% of radically treated patients, and 24% of palliatively treated patients. Partial regression was observed in 56% of radically treated patients, and 58% of palliatively treated patients. Long-term local tumour control was more commonly observed for small tumours (< 5 cm diameter). Fifty-eight % of patients treated with postoperative radiotherapy remained free of local recurrence. Survival was significantly better with small tumours. The addition of 5FU did not appear to improve survival or tumour control. (author)

  3. The ionoluminescence apparatus at the LABEC external microbeam facility

    International Nuclear Information System (INIS)

    Calusi, S.; Colombo, E.; Giuntini, L.; Giudice, A. Lo; Manfredotti, C.; Massi, M.; Pratesi, G.; Vittone, E.

    2008-01-01

    In this paper, we describe the main features of the ionoluminescence (IL) apparatus recently installed at the external scanning microbeam facility of the 3 MV Tandetron accelerator of the INFN LABEC Laboratory in Firenze. The peculiarity of this IL set-up resides in the fact that the light produced by the ion irradiation of the specimen is collected by a bifurcated optical fiber, so that photons are shunted both to a CCD spectrometer, working in the 200-900 nm wavelength range, and to a photomultiplier (PMT). The accurate focusing of the optical system allows high photon collection efficiency and this results in rapid acquisition of luminescence spectra with low ion currents on luminescent materials; simultaneously, luminescence maps with a spatial resolution of 10 μm can be acquired through the synchronization of PMT photon detection with the position of the scanning focused ion beam. An optical filter with a narrow passband facing the photomultiplier allows chromatic selectivity of the luminescence centres. The IL apparatus is synergistically integrated into the existing set-up for ion beam analyses (IBA). The upgraded system permits simultaneous IL and PIXE/PIGE/BS measurements. With our integrated system, we have been studying raw lapis lazuli samples of different known origins and precious lapis lazuli artworks of the Collezione Medicea of Museum of Natural History, University of Firenze, aiming at characterising their composition and provenance

  4. The ionoluminescence apparatus at the LABEC external microbeam facility

    Energy Technology Data Exchange (ETDEWEB)

    Calusi, S.; Colombo, E. [INFN Sezione di Torino, Via P.Giuria 1, 10125 Torino (Italy); Dipartimento di Fisica Sperimentale and NIS Excellence Centre, Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy); Giuntini, L. [Dipartimento di Fisica, Universita and INFN Sezione di Firenze, Via Sansone 1, 50019, Sesto Fiorentino, Firenze (Italy)], E-mail: giuntini@fi.infn.it; Giudice, A. Lo [Dipartimento di Fisica Sperimentale and NIS Excellence Centre, Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy); Manfredotti, C. [INFN Sezione di Torino, Via P.Giuria 1, 10125 Torino (Italy); Dipartimento di Fisica Sperimentale and NIS Excellence Centre, Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy); Massi, M. [Dipartimento di Fisica, Universita and INFN Sezione di Firenze, Via Sansone 1, 50019, Sesto Fiorentino, Firenze (Italy); Pratesi, G. [Dipartimento di Scienze della Terra and Museo di Storia Naturale, Universita di Firenze, Via G. La Pira 4, 50121 Firenze (Italy); Vittone, E. [INFN Sezione di Torino, Via P.Giuria 1, 10125 Torino (Italy); Dipartimento di Fisica Sperimentale and NIS Excellence Centre, Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy)

    2008-05-15

    In this paper, we describe the main features of the ionoluminescence (IL) apparatus recently installed at the external scanning microbeam facility of the 3 MV Tandetron accelerator of the INFN LABEC Laboratory in Firenze. The peculiarity of this IL set-up resides in the fact that the light produced by the ion irradiation of the specimen is collected by a bifurcated optical fiber, so that photons are shunted both to a CCD spectrometer, working in the 200-900 nm wavelength range, and to a photomultiplier (PMT). The accurate focusing of the optical system allows high photon collection efficiency and this results in rapid acquisition of luminescence spectra with low ion currents on luminescent materials; simultaneously, luminescence maps with a spatial resolution of 10 {mu}m can be acquired through the synchronization of PMT photon detection with the position of the scanning focused ion beam. An optical filter with a narrow passband facing the photomultiplier allows chromatic selectivity of the luminescence centres. The IL apparatus is synergistically integrated into the existing set-up for ion beam analyses (IBA). The upgraded system permits simultaneous IL and PIXE/PIGE/BS measurements. With our integrated system, we have been studying raw lapis lazuli samples of different known origins and precious lapis lazuli artworks of the Collezione Medicea of Museum of Natural History, University of Firenze, aiming at characterising their composition and provenance.

  5. Advanced characterization of materials using swift ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Tabacniks, Manfredo H. [Universidade de Sao Paulo (USP), SP (Brazil)

    2011-07-01

    Swift ion beams are powerful non destructive tools for material analysis especially thin films. In spite of their high energy, usually several MeV/u, little energy is deposited by the ion on the sample. Energetic ions also use to stop far away (or outside) the inspected volume, hence producing negligible damage to the sample. Ion beam methods provide quantitative trace element analysis of any atomic element (and some isotopes) in a sample and are able to yield elemental depth profiles with spatial resolution of the order of 10mm. Relying on nuclear properties of the atoms, these methods are insensitive to the chemical environment of the element, consequently not limited by matrix effects. Ion beam methods are multielemental, can handle insulating materials, are quick (an analysis usually takes less than 15 minutes), and need little (if any) sample preparation. Ion beams are also sensitive to surface roughness and sample porosity and can be used to quickly inspect these properties in a sample. The Laboratory for Ion Beam Analysis of the University of Sao Paulo, LAMFI, is a multi-user facility dedicated to provide Ion Beam Methods like PIXE, RBS, FRS and NRA techniques for the analysis of materials and thin films. Operating since 1994, LAMFI is being used mostly by many researchers from within and outside USP, most of them non specialists in ion beam methods, but in need of ion beam analysis to carry out their research. At LAMFI, during the last 9 years, more than 50% of the accelerator time was dedicated to analysis, usually PIXE or RBS. 21% was down time and about 14% of the time was used for the development of ion beam methods which includes the use of RBS for roughness characterization exploring the shading of the beam by structures on the surface and by modeling the RBS spectrum as the product of a normalized RBS spectrum and a height density distribution function of the surface. Single element thick target PIXE analysis is being developed to obtain the thin

  6. Advanced characterization of materials using swift ion beams

    International Nuclear Information System (INIS)

    Tabacniks, Manfredo H.

    2011-01-01

    Swift ion beams are powerful non destructive tools for material analysis especially thin films. In spite of their high energy, usually several MeV/u, little energy is deposited by the ion on the sample. Energetic ions also use to stop far away (or outside) the inspected volume, hence producing negligible damage to the sample. Ion beam methods provide quantitative trace element analysis of any atomic element (and some isotopes) in a sample and are able to yield elemental depth profiles with spatial resolution of the order of 10mm. Relying on nuclear properties of the atoms, these methods are insensitive to the chemical environment of the element, consequently not limited by matrix effects. Ion beam methods are multielemental, can handle insulating materials, are quick (an analysis usually takes less than 15 minutes), and need little (if any) sample preparation. Ion beams are also sensitive to surface roughness and sample porosity and can be used to quickly inspect these properties in a sample. The Laboratory for Ion Beam Analysis of the University of Sao Paulo, LAMFI, is a multi-user facility dedicated to provide Ion Beam Methods like PIXE, RBS, FRS and NRA techniques for the analysis of materials and thin films. Operating since 1994, LAMFI is being used mostly by many researchers from within and outside USP, most of them non specialists in ion beam methods, but in need of ion beam analysis to carry out their research. At LAMFI, during the last 9 years, more than 50% of the accelerator time was dedicated to analysis, usually PIXE or RBS. 21% was down time and about 14% of the time was used for the development of ion beam methods which includes the use of RBS for roughness characterization exploring the shading of the beam by structures on the surface and by modeling the RBS spectrum as the product of a normalized RBS spectrum and a height density distribution function of the surface. Single element thick target PIXE analysis is being developed to obtain the thin

  7. Some peculiarity of element analysis using charged particle beams

    International Nuclear Information System (INIS)

    Kobzev, A.P.; Abu-Alazm, S.M.; Helal, A.I.; Zahran, N.F.

    2002-01-01

    Multilayer structures, SiC -layers at Si substrate, have been analyzed by RBS, NR, ERD and PIXE methods using the charged particle beams from EG-5 Van de Graaff accelerator of JINR. The depth profiles of the based deposited layers were obtained for the multilayer structures

  8. Proton-induced X-ray emission (PIXE) spectrometry - state of the art

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1986-01-01

    The development of the PIXE method for multielemental analysis is described. A brief account is given of the physical principles and the experimental arrangements. The use of PIXE is illustrated by a number of typical applications in geology, biology, medicine and environmental research. (orig.) [de

  9. Improving external beam radiotherapy by combination with internal irradiation.

    Science.gov (United States)

    Dietrich, A; Koi, L; Zöphel, K; Sihver, W; Kotzerke, J; Baumann, M; Krause, M

    2015-07-01

    The efficacy of external beam radiotherapy (EBRT) is dose dependent, but the dose that can be applied to solid tumour lesions is limited by the sensitivity of the surrounding tissue. The combination of EBRT with systemically applied radioimmunotherapy (RIT) is a promising approach to increase efficacy of radiotherapy. Toxicities of both treatment modalities of this combination of internal and external radiotherapy (CIERT) are not additive, as different organs at risk are in target. However, advantages of both single treatments are combined, for example, precise high dose delivery to the bulk tumour via standard EBRT, which can be increased by addition of RIT, and potential targeting of micrometastases by RIT. Eventually, theragnostic radionuclide pairs can be used to predict uptake of the radiotherapeutic drug prior to and during therapy and find individual patients who may benefit from this treatment. This review aims to highlight the outcome of pre-clinical studies on CIERT and resultant questions for translation into the clinic. Few clinical data are available until now and reasons as well as challenges for clinical implementation are discussed.

  10. Advances in elemental imaging of rocks using the AGLAE external microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T., E-mail: thomas.calligaro@culture.gouv.fr [Centre de Recherche et de Restauration des musees de France, CNRS UMR171, Palais du Louvre, 75001 Paris (France); Coquinot, Y.; Pichon, L.; Moignard, B. [Centre de Recherche et de Restauration des musees de France, CNRS UMR171, Palais du Louvre, 75001 Paris (France)

    2011-10-15

    Rocks are widely represented in cultural heritage materials. They constitute the major part of archaeological artefacts like stone carvings, tools and weapons, and are present in art works in various forms, such as precious stone inlays or paint pigments. The study of such geomaterials, which are usually constituted of a complex aggregate of mineral phases, aims at determining their exact nature, their provenance and at understanding their possible alteration. Since minerals are often composed of light elements, IBA techniques such as PIXE and PIGE, thanks to their ability to measure with high sensitivity elements down to lithium, should be well adapted to their analysis. However, the bulk composition classically obtained using macro-IBA on pelletized samples or using a broad beam hides the multi-phased nature of the rocks and considerably blurs the searched chemical fingerprint. In contrast, the small size of a nuclear microprobe allows imaging the chemical composition at a finer scale and, when implemented in air, appears ideally suited to analyse without sampling these often precious items. This paper illustrates chemical micro-imaging of rocks with examples performed with the AGLAE external nuclear microprobe: characterisation of microscopic inclusions in gems and detailed chemical mapping of rocks with special emphasis to lapis lazuli. Lapis lazuli is of particular interest in both archaeology and art history: after being employed in Asia since the 7th millennium BC to make carvings and beads, it was used in Medieval Europe as a precious blue painting pigment known as ultramarine. The chemical imaging of major and trace elements in lapis lazuli using external {mu}-PIXE has permitted to identify its mineral phases, to assign their trace elements and to evidence undetected elements. In combination with {mu}-XRD and {mu}-Raman spectrometry, this approach provides a clear mineralogical fingerprint useful to determine rock provenance and to authenticate artefacts

  11. Advances in elemental imaging of rocks using the AGLAE external microbeam

    International Nuclear Information System (INIS)

    Calligaro, T.; Coquinot, Y.; Pichon, L.; Moignard, B.

    2011-01-01

    Rocks are widely represented in cultural heritage materials. They constitute the major part of archaeological artefacts like stone carvings, tools and weapons, and are present in art works in various forms, such as precious stone inlays or paint pigments. The study of such geomaterials, which are usually constituted of a complex aggregate of mineral phases, aims at determining their exact nature, their provenance and at understanding their possible alteration. Since minerals are often composed of light elements, IBA techniques such as PIXE and PIGE, thanks to their ability to measure with high sensitivity elements down to lithium, should be well adapted to their analysis. However, the bulk composition classically obtained using macro-IBA on pelletized samples or using a broad beam hides the multi-phased nature of the rocks and considerably blurs the searched chemical fingerprint. In contrast, the small size of a nuclear microprobe allows imaging the chemical composition at a finer scale and, when implemented in air, appears ideally suited to analyse without sampling these often precious items. This paper illustrates chemical micro-imaging of rocks with examples performed with the AGLAE external nuclear microprobe: characterisation of microscopic inclusions in gems and detailed chemical mapping of rocks with special emphasis to lapis lazuli. Lapis lazuli is of particular interest in both archaeology and art history: after being employed in Asia since the 7th millennium BC to make carvings and beads, it was used in Medieval Europe as a precious blue painting pigment known as ultramarine. The chemical imaging of major and trace elements in lapis lazuli using external μ-PIXE has permitted to identify its mineral phases, to assign their trace elements and to evidence undetected elements. In combination with μ-XRD and μ-Raman spectrometry, this approach provides a clear mineralogical fingerprint useful to determine rock provenance and to authenticate artefacts of

  12. Cervix Regression and Motion During the Course of External Beam Chemoradiation for Cervical Cancer

    International Nuclear Information System (INIS)

    Beadle, Beth M.; Jhingran, Anuja; Salehpour, Mohammad; Sam, Marianne; Iyer, Revathy B.; Eifel, Patricia J.

    2009-01-01

    Purpose: To evaluate the magnitude of cervix regression and motion during external beam chemoradiation for cervical cancer. Methods and Materials: Sixteen patients with cervical cancer underwent computed tomography scanning before, weekly during, and after conventional chemoradiation. Cervix volumes were calculated to determine the extent of cervix regression. Changes in the center of mass and perimeter of the cervix between scans were used to determine the magnitude of cervix motion. Maximum cervix position changes were calculated for each patient, and mean maximum changes were calculated for the group. Results: Mean cervical volumes before and after 45 Gy of external beam irradiation were 97.0 and 31.9 cc, respectively; mean volume reduction was 62.3%. Mean maximum changes in the center of mass of the cervix were 2.1, 1.6, and 0.82 cm in the superior-inferior, anterior-posterior, and right-left lateral dimensions, respectively. Mean maximum changes in the perimeter of the cervix were 2.3 and 1.3 cm in the superior and inferior, 1.7 and 1.8 cm in the anterior and posterior, and 0.76 and 0.94 cm in the right and left lateral directions, respectively. Conclusions: Cervix regression and internal organ motion contribute to marked interfraction variations in the intrapelvic position of the cervical target in patients receiving chemoradiation for cervical cancer. Failure to take these variations into account during the application of highly conformal external beam radiation techniques poses a theoretical risk of underdosing the target or overdosing adjacent critical structures

  13. ePix: a class of architectures for second generation LCLS cameras

    International Nuclear Information System (INIS)

    Dragone, A; Caragiulo, P; Markovic, B; Herbst, R; Reese, B; Herrmann, S C; Hart, P A; Segal, J; Carini, G A; Kenney, C J; Haller, G

    2014-01-01

    ePix is a novel class of ASIC architectures, based on a common platform, optimized to build modular scalable detectors for LCLS. The platform architecture is composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog-to-digital converters per column. It also implements a dedicated control interface and all the required support electronics to perform configuration, calibration and readout of the matrix. Based on this platform a class of front-end ASICs and several camera modules, meeting different requirements, can be developed by designing specific pixel architectures. This approach reduces development time and expands the possibility of integration of detector modules with different size, shape or functionality in the same camera. The ePix platform is currently under development together with the first two integrating pixel architectures: ePix100 dedicated to ultra low noise applications and ePix10k for high dynamic range applications.

  14. Fish otoliths analysis by PIXE: application to stock discrimination

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Takai, Noriyuki; Sakamoto, Wataru; Yoshida, Koji; Maeda, Kuniko.

    1996-01-01

    Fish otoliths are continuously deposited from fish birth to its death along with encoding environmental information. In order to decode the information, PIXE was adopted as trace elemental analysis of the otoliths. Strontium to calcium concentration ratios of red sea bream otoliths varied among rearing stations. The Sr/Ca ratios of Lake Biwa catfishes also varied between male and female and among fishing grounds. The PIXE analysis was applied to the fish stock discrimination. (author)

  15. Scanning ion micro-beam techniques for measuring diffusion in heterogeneous materials

    International Nuclear Information System (INIS)

    Jenneson, P.M.; Clough, A.S.

    1998-01-01

    A raster scanning MeV micro-beam of 1 H + or 3 He + ions was used to study the diffusion of small molecules in heterogeneous materials. The location of elemental contaminants (heavier than Lithium) in polymer insulated cables was studied with 1 H micro-Particle Induced X-ray Emission (μPIXE). Concentration profiles of a deuterated molecule in a hair fibre were determined with 3 He micro-Nuclear Reaction Analysis (μNRA). Chlorine and heavy water (D 2 0) diffusion into cement pastes were profiled using a combination of 3 He μPIXE and μNRA. (authors)

  16. Performance of Retrofitted Self-Compacting Concrete-Filled Steel Tube Beams Using External Steel Plates

    Directory of Open Access Journals (Sweden)

    Ahmed A. M. AL-Shaar

    2018-01-01

    Full Text Available Self-compacting concrete-filled steel tube (SCCFST beams, similar to other structural members, necessitate retrofitting for many causes. However, research on SCCFST beams externally retrofitted by bolted steel plates has seldom been explored in the literature. This paper aims at experimentally investigating the retrofitting performance of square self-compacting concrete-filled steel tube (SCCFST beams using bolted steel plates with three different retrofitting schemes including varied configurations and two different steel plate lengths under flexure. A total of 18 specimens which consist of 12 retrofitted SCCFST beams, three unretrofitted (control SCCFST beams, and three hollow steel tubes were used. The flexural behaviour of the retrofitted SCCFST beams was examined regarding flexural strength, failure modes, and moment versus deflection curves, energy absorption, and ductility. Experimental results revealed that the implemented retrofitting schemes efficiently improve the moment carrying capacity and stiffness of the retrofitted SCCFST beams compared to the control beams. The increment in flexural strength ranged from 1% to 46%. Furthermore, the adopted retrofitting schemes were able to restore the energy absorption and ductility of the damaged beams in the range of 35% to 75% of the original beam ductility. Furthermore, a theoretical model was suggested to predict the moment capacity of the retrofitted SCCFST beams. The theoretical model results were in good agreement with the test results.

  17. Surrey Ion Beam Centre: the EPSRC MRF for ion beam applications - 01002

    International Nuclear Information System (INIS)

    Webb, R.P.

    2016-01-01

    The SIBC (Surrey Ion Beam Centre) is an element of the Virtual Ion Beam Centre that coordinates 3 U.K. experimental facilities: SIBC (University of Surrey) for implantation and ion beam applications, Miami and MEIS facility (University of Huddersfield) and gamma ray and neutron irradiation emulation facility (University of Manchester). The SIBC works actively with industry, developing bespoke processes and services, particularly for the photonics industry and provides ion beam facilities to about 20 companies across the world. It operates a stringent quality control program and is one of the few ion beam laboratories in the world to operate under ISO 9001 certification. The equipment of SIBC is presented and some applications of ion beam analysis concerning the identification of gunshot residues, the determination of the origin of a painting, the analysis of proteins are described. Different techniques such as PIXE (Particle Induced X-ray Emission), RBS (Rutherford Backscattering Spectroscopy), NRA (Nuclear Reaction Analysis), SIMS (Secondary Ion Mass Spectrometry) are also explained in the slides of the presentation that have been added at the end of the paper

  18. Transmission property and its applications of MeV ion beams with various capillaries

    International Nuclear Information System (INIS)

    Fujita, N; Ishii, K; Ogawa, H

    2012-01-01

    In order to clarify transmission properties of an ion beam extracted with various capillaries into the air, we have measured intensity distributions for the core and the halo components of MeV ion beams using various capillaries. In addition, we have performed in-air-RBS and in-air-PIXE from the point of the application. At the conference, progress report of transmission properties of ion beams with various capillaries and its applications will be presented.

  19. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    International Nuclear Information System (INIS)

    Alvarez R, J T; Tovar M, V M

    2008-01-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D W = 2 Gy·c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D W for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals

  20. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    Science.gov (United States)

    Álvarez R., J. T.; Tovar M., V. M.

    2008-08-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described—for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 °C plus 24 hrs 80 °C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal DW = 2 Gy ṡ c ) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water DW for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

  1. A new ion beam facility based on a 3 MV Tandetron™ at IFIN-HH, Romania

    Science.gov (United States)

    Burducea, I.; Straticiuc, M.; Ghiță, D. G.; Moșu, D. V.; Călinescu, C. I.; Podaru, N. C.; Mous, D. J. W.; Ursu, I.; Zamfir, N. V.

    2015-09-01

    A 3 MV Tandetron™ accelerator system has been installed and commissioned at the "Horia Hulubei" National Institute for Physics and Nuclear Engineering - IFIN-HH, Măgurele, Romania. The main purpose of this machine is to strengthen applied nuclear physics research ongoing in our institute for more than four decades. The accelerator system was developed by High Voltage Engineering Europa B.V. (HVE) and comprises three high energy beam lines. The first beam line is dedicated to ion beam analysis (IBA) techniques: Rutherford Backscattering Spectrometry - RBS, Nuclear Reaction Analysis - NRA, Particle Induced X-ray and γ-ray Emission - PIXE and PIGE and micro-beam experiments - μ-PIXE. The second beam line is dedicated to high energy ion implantation experiments and the third beam line was designed mainly for nuclear cross-sections measurements used in nuclear astrophysics. A unique feature, the first time in operation at an accelerator facility is the Na charge exchange canal (CEC), which is used to obtain high intensity beams of He- of at least 3 μA. The results of the acceptance tests demonstrate the huge potential of this new facility in various fields, from IBA to radiation hardness studies and from medical or environmental applications to astrophysics. The main features of the accelerator are presented in this paper.

  2. Beam-envelope calculations of space-charge loaded beams in MeV dc ion-implantation facilities

    International Nuclear Information System (INIS)

    Urbanus, W.H.; Bannenberg, J.G.; Doorn, S.; Saris, F.W.; Koudijs, R.; Dubbelman, P.; Koelewijn, W.

    1989-01-01

    MeV dc ion accelerators are being developed that can deliver a beam current up to several hundred micro-amperes. At the low-energy part of the accelerator, the beam transport is space-charge dominated rather than emittance dominated. A system of differential equations has been derived, based on the Kapchinski-Vladimirski equations, which describe the envelope of a space-charge loaded ion beam, taking a longitudinal electrical field in an accelerating tube into account. The equations have been used to design the accelerator of a high-current 1 MV heavy-ion implantation facility. Furthermore, the design of a 2 MV accelerator is presented, which is used for analyzing techniques such as RBS and PIXE. Both facilities are based on single-ended Van de Graaff accelerators. (orig.)

  3. Instrumentation for PIXE and RBS

    International Nuclear Information System (INIS)

    2000-12-01

    The purpose of this document is to give an overview of instrumentation for PIXE and Rutherford backscattering analysis, including hardware and software needed to perform the analysis, including detectors, analyzers, data acquisition systems and data analysis software. It also provides some information on accelerators needed for these applications

  4. Expert Images for All Audiences: The AstroPix Archive

    Science.gov (United States)

    Hurt, Robert; Llamas, Jacob; Wyatt, Ryan Jason; Christensen, Lars

    2018-01-01

    The AstroPix project provides one-stop-shopping for an extensive collection of the finest astronomical imagery, sourced from some of the world’s most prominent observatories. The archive is made possible by a grassroots effort to tag publicly-released imagery using the Astronomical Visualization Metadata (AVM) standard, which captures rich contextual information for each image. While the site has been in development for many years, it is now supported under NASA’s Universe of Learning collaboration, and AstroPix has been updated and deployed to cloud services. The AVM tags provide many unique features including spectral color assignments, sky context (using AAS WorldWide Telescope APIs), and direct links to the original source material on the web. The 7,000+ assets currently include imagery provided by Chandra, ESO, GALEX, Herschel, Hubble, NuSTAR, Spitzer, and WISE. The assets are also provided for use in the planetarium community by supporting the Data2Dome (D2D) initiative. AstroPix imagery is designed to be used in a variety of unique ways that benefit formal and informal education as well as astronomers and the general public. Observatories can add their own image archives to AstroPix by tagging their assets and providing a simple XML feed, increasing the value of their data to the community at large.

  5. Controversies in external beam and high dose rate brachytherapy of oesophageal cancer

    International Nuclear Information System (INIS)

    Sur, R.K.; Levin, V.C.; Malas, Simon; Donde, Bernard

    1994-01-01

    Various controversies in the treatment of oesophageal carcinoma with external beam radiotherapy and high dose rate intracavitary irradiation have been reviewed. Conflicting results from different parts of the world has made it difficult to optimize the radiation dose that may give the best results. More studies and longer follow-up are needed before a definite conclusion can be made on the optimization of dose. (author). 18 refs., 2 tabs

  6. Matrix effects in PIXE evaluation of the major components in thick homogeneous samples

    International Nuclear Information System (INIS)

    Oystaeyen, B. van; Demortier, G.

    1983-01-01

    Matrix effects on the major component X-ray yields in PIXE measurements are studied in general terms with the Au-Cu-Ag matrix as practical example. Postulating firstly that all the major components may be simultaneously detected through one well-isolated peak for each of them, and secondly that a known reference material is available which contains all the elements of the unknown sample, we propose a direct method to extract the true concentrations of the latter taking into accout the matrix effects. The geometrical parameters describing the target location with respect to ion beam direction and detector position are also studied and a first attempt is made to include them in the data treatment. (orig.)

  7. Numerical simulation on the energy spectrum of the electron beam generated by low-impedance diode and the influence of external magnetic field on diode impedance

    International Nuclear Information System (INIS)

    Liu Guozhi

    2003-01-01

    The energy spectrum of the electron beam generated by low-impedance diode and the influence of external magnetic field on the impedance of diode are studied numerically in this paper. The results show that the beam generated by the diode has an energy spread, even with constant applied voltage. Additionally, external magnetic field has great but reverse influence on the impedance of low-impedance diode, which is, according to the author's analysis, the result of the change of the electron's track due to external magnetic field. If the beam current is less than the critical one for self-pinch, the impedance will be constant with the variation of external magnetic field

  8. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  9. Prehispanic goldwork technology study by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro, E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Climent Font, Aurelio [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Gutierrez Neira, Patricia Carolina; Perea, Alicia [Centro de Ciencias Humanas y Sociales, CSIC, Calle Albasanz 26-28, Madrid 28037 (Spain); Fernandez Esquivel, Patricia [Fundación Museos, Banco Central de Costa Rica, San José (Costa Rica); Rovira Llorens, Salvador [Museo Arqueológico Nacional, Calle Serrano 13, Madrid 28006 (Spain); Ruvalcaba Sil, José Luis [Instituto de Física, Universidad Nacional Autónoma de Mexico, Mexici DF 28006 (Mexico); Verde, Ana [Museo de América, Avda. de los Reyes Católicos 6, Madrid 28040 (Spain)

    2014-08-01

    Technological characterization of pre-Hispanic gold metallurgy has still a wide deficit of analytical data. A set of 103 pieces from the so called “Quimbaya’s treasure” (QT) and the “Costa Rica collection” (CRC) of the Museo de America of Madrid were submitted to IBA analysis (PIXE and RBS) at the CMAM in three phases and the metal composition was determined. Only in a limited number of cases, due to the dramatic erosion of the gilded layer, produced by abrasive cleaning methods applied after the discovery and before the seventies, it was possible to determine also the sequence of layers, which gives information on the manufacture technology and the type and purity of the metals. PIXE results are reported and discussed. Data show that the CRC objects have very high gold levels (>80% in weight) while the QT have a more variable composition with significant Cu levels associated to the so called Tumbaga-alloy. In the cases where polishing had a tolerable effect, PIXE (and RBS), point to depletion gilding as a standard finishing process in the Costa Rica production, resulting in a gold rich surface alloy, while the variable composition of the QT objects may well be linked to deliberate colour choice.

  10. PIXE analysis of ancient Chinese Qing dynasty porcelain

    Science.gov (United States)

    Cheng, Huansheng; He, Wenquan; Tang, Jiayong; Yang, Fujia; Wang, Jianhua

    1996-09-01

    The major and minor chemical compositions and trace element content of white glaze made in Qing dynasty at kuan kiln have been determined by PIXE. Experimental results show that trace element contents RbSrZr are useful to distinguish the place of production of ancient porcelain. In the porcelain from different kilns situated in a same province, the trace element contents can be different from each other. Determining and comparing the major and minor compositions and trace elemental concentrations in white glaze by PIXE technique, we can distinguish a precious Qing dynasty porcelain made at kuan kiln from a fake.

  11. Proton external beam in the TANDAR Accelerator; Haz externo de protones en el acelerador TANDAR

    Energy Technology Data Exchange (ETDEWEB)

    Rey, R; Schuff, J A; Perez de la Hoz, A.; Debray, M E; Hojman, D; Kreiner, A J; Kesque, J M; Saint-Martin, G; Oppezzo, O; Bernaola, O A; Molinari, B L; Duran, H A; Policastro, L; Palmieri, M; Ibanez, J; Stoliar, P; Mazal, A; Caraballo, M E; Burlon, A; Cardona, M A; Vazquez, M E; Salfity, M F; Ozafran, M J; Naab, F; Levinton, G; Davidson, M; Buhler, M [Departamento de Fisica, Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, C.P. 1650 San Martin, Buenos Aires (Argentina)

    1999-12-31

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm{sup 2} approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  12. Proton external beam in the TANDAR Accelerator; Haz externo de protones en el acelerador TANDAR

    Energy Technology Data Exchange (ETDEWEB)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M. [Departamento de Fisica, Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, C.P. 1650 San Martin, Buenos Aires (Argentina)

    1998-12-31

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm{sup 2} approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  13. MO-A-BRB-01: Review of TG-262 Internal Survey of Practices in EMR for External Beam Therapy

    International Nuclear Information System (INIS)

    Mechalakos, J.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  14. Elemental analysis of river sediments by PIXE and PIGE

    International Nuclear Information System (INIS)

    Kennedy, V.J.; Augusthy, A.; Varier, K.M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.; Vijayan, V.

    1999-01-01

    The Chaliyar river, located in Kerala, India has shown preoccupying pollution levels, that constitute a threat to public health and the ecological system. PIXE and PIGE techniques have been employed to measure the elemental concentrations in the river sediment samples. Thick targets were prepared out of the sediment samples collected from various sites along the course of the river. The measurements were carried out using 3 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at Institute of Physics, Bhubaneswar. The elemental concentrations, especially that of heavy metals, at different sites are discussed in detail. Our results show that sediments from a site where the industrial activities are high are significantly high in concentrations of heavy metals (Cr, Ni, Cu, Zn, Hg and Pb) than those collected from non-industrial sites. The measured values are compared with the average composition of unpolluted river sediments and other national and international river sediments. (author)

  15. External proton and Li beams; Haces externos de protones y litios

    Energy Technology Data Exchange (ETDEWEB)

    Schuff, Juan A; Burlon, Alejandro A; Debray, Mario E; Kesque, Jose M; Kreiner, Andres J; Stoliar, Pablo A; Naab, Fabian; Ozafran, Mabel J; Vazquez, Monica E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Fisica; Policastro, Lucia L; Duran, Hebe; Molinari, Beatriz L; O' Connor, Silvia E; Saint-Martin, Maria L.G.; Palmieri, Monica; Bernaola, Omar A; Opezzo, Oscar J [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia; Mazal, A; Favaudon, F; Henry, Y [Institut Curie, 75 - Paris (France); Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S; Ruffolo, M; Tasat, D R [Universidad Nacional de General San Martin, Villa Ballester (Argentina). Escuela de Ciencia y Tecnologia; Davidson, Miguel; Davidson, Jorge [Buenos Aires Univ. (Argentina). Dept. de Fisica; Delacroix, S; Nauraye, C; Brune, E; Gautier, C; Habrand, J L [Centre de Protontherapie, 91 - Orsay (France); Muhlmann, M C [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina)

    2000-07-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 {mu}m gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 {+-} 0.07 MeV, 2.9 {+-} 0.10 MeV y 1.5 {+-} 0.1 MeV for protons and 21.4 {+-} 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with {gamma}-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/{mu}m. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  16. External Beam Boost for Cancer of the Cervix Uteri When Intracavitary Therapy Cannot Be Performed

    International Nuclear Information System (INIS)

    Barraclough, Lisa Helen; Swindell, Ric; Livsey, Jacqueline E.; Hunter, Robin D.; Davidson, Susan E.

    2008-01-01

    Purpose: To assess the outcome of patients treated with radical radiotherapy for cervical cancer who received an external beam boost, in place of intracavitary brachytherapy (ICT), after irradiation to the whole pelvis. Methods and Materials: Case notes were reviewed for all patients treated in this way in a single center between 1996 and 2004. Patient and tumor details, the reasons why ICT was not possible, and treatment outcome were documented. Results: Forty-four patients were identified. The mean age was 56.4 years (range, 26-88 years). Clinical International Federation of Gynecology and Obstetrics or radiologic stage for Stages I, II, III, and IV, respectively, was 16%, 48%, 27%, and 7%. A total radiation dose of 54-70 Gy was given (75% received ≥60 Gy). Reasons for ICT not being performed were technical limitations in 73%, comorbidity or isolation limitations in 23%, and patient choice in 4%. The median follow-up was 2.3 years. Recurrent disease was seen in 48%, with a median time to recurrence of 2.3 years. Central recurrence was seen in 16 of the 21 patients with recurrent disease. The 5-year overall survival rate was 49.3%. The 3-year cancer-specific survival rate by stage was 100%, 70%, and 42% for Stages I, II, and III, respectively. Late Grades 1 and 2 bowel, bladder, and vaginal toxicity were seen in 41%. Late Grade 3 toxicity was seen in 2%. Conclusion: An external beam boost is a reasonable option after external beam radiotherapy to the pelvis when it is not possible to perform ICT

  17. Pixe method as microanalytical instrument

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1986-02-01

    The PIXE method (Particle Induced X-Ray Emission) as analytical method presenting the evolution, the theoretical fundaments, the detection limit, the optimization for operational conditions is evaluated. The applications of the method to air pollution control and aerosol studies in regions such as Antartic, Amazon and other regions are analysed. (M.C.K.) [pt

  18. Ion beam analysis of Cu(In,Ga)Se{sub 2} thin film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Karydas, A.G. [International Atomic Energy Agency (IAEA), IAEA Laboratories, Nuclear Science and Instrumentation Laboratory, A-2444 Seibersdorf (Austria); Institute of Nuclear and Particle Physics, NCSR “Demokritos”, 153 10 Aghia Paraskevi, Athens Greece (Greece); Streeck, C. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Radovic, I. Bogdanovic [Ruđer Bošković Institute (RBI), Zagreb (Croatia); Kaufmann, C.; Rissom, T. [Helmholtz-Zentrum Berlin für Materialien und Energie GmbH (HZB), Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Beckhoff, B. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Jaksic, M. [Ruđer Bošković Institute (RBI), Zagreb (Croatia); Barradas, N.P. [Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, E. N. 10, Apartado 21, 2686-953 Sacavém (Portugal)

    2015-11-30

    Graphical abstract: - Highlights: • Elemental depth profiles for various CIGS thin films were quantitatively determined. • Pure absorbers, complete cell and bilayer solar cells were prepared and analyzed. • Synergistic PIXE and RBS analysis of thin solar cells using alpha beam particles. • High energy alpha beam resolved completely the Indium depth profile. • Synchrotron based Reference Free GIXRF quantitative analysis validated IBA results. - Abstract: The present work investigates the potential of ion beam analysis (IBA) techniques such as the Rutherford backscattering spectrometry (RBS) and particle induced X-ray emission (PIXE) using helium ions to provide quantitative in-depth elemental analysis of various types of Cu(In,Ga)Se{sub 2} thin films. These films with a thickness of about 2 μm are used as absorber layers in photovoltaic devices with continuously increasing the performance of this technology. The preparation process generally aims to obtain an in-depth gradient of In and Ga concentrations that optimizes the optoelectronic and electrical properties of the solar cell. The measurements were performed at directly accessible single or double layered CIGS absorbers and at buried absorbers in completed thin film solar cells. The IBA data were analyzed simultaneously in order to derive best fitted profiles that match all experimental RBS and PIXE spectra. For some samples elemental profiles deduced form synchrotron based, reference free grazing incidence X-ray fluorescence analysis were compared with the IBA results and an overall good agreement was observed within quoted uncertainties.

  19. Monitoring external beam radiotherapy using real-time beam visualization

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, Cesare H. [Department of Mechanical Engineering and Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Naczynski, Dominik J.; Yu, Shu-Jung S.; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States)

    2015-01-15

    Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

  20. Olfactory neural tumours - the role of external beam radiotherapy

    International Nuclear Information System (INIS)

    Slevin, N.J.; Irwin, C.J.R.; Banerjee, S.S.; Path, F.R.C.; Gupta, N.K.; Farrington, W.T.

    1996-01-01

    Olfactory neuroblastoma is an uncommon tumour arising in the nasal cavity or paranasal sinuses. We report the management of nine cases treated with external beam radiotherapy subsequent to surgery, either attempted definitive removal or biopsy only. Recent refinements in pathological evaluation of these tumours are discussed. Seven cases were deemed classical olfactory neuroblastoma whilst two were classified as neuroendocrine carcinoma. The clinical features, radiotherapy technique and variable natural history are presented. Seven of eight patients treated radically were controlled locally, with a minimum follow-up of two years. Three patients developed cervical lymph node disease and three patients died of systemic metastatic disease. Suggestions are made as to which patients should have en-bloc resection rather than definitive radiotherapy. (author)

  1. PIXE and its applications to biological samples

    International Nuclear Information System (INIS)

    Aldape, F.; Flores, M.J.

    1996-01-01

    Throughout this century, industrialized society has seriously affected the ecology by introducing huge amounts of pollutants into the atmosphere as well as marine and soil environments. On the other hand, it is known that these pollutants, in excess of certain levels of concentration, not only put at risk the life of living beings but may also cause the extinction of some species. It is therefore of basic importance to substantially increase quantitative determinations of trace element concentrations in biological specimens in order to assess the effects of pollutants. It is in this field that PIXE plays a key role in these studies, where its unique analytical properties are decisive. Moreover, since the importance of these research has been recognized in many countries, many scientists have been encouraged to continue or initiate new research programmes aimed to solve the worldwide pollution problem. This document presents an overview of those papers reporting the application of PIXE analysis to biological samples during this last decade of the 20th century and recounts the number of PIXE laboratories dedicating their efforts to find the clues of the biological effects of the presence of pollutants introduced in living beings. Sample preparation methods, different kinds of samples under study and the use of complementary analytical techniques are also illustrated. (author). 108 refs

  2. PIXE and XRF Analysis of Roman Denarii

    Science.gov (United States)

    Fasano, Cecilia; Raddell, Mark; Manukyan, Khachatur; Stech, Edward; Wiescher, Michael

    2017-09-01

    A set of Roman Denarii from the republican to the imperial period (140BC-240AD) has been studied using X-ray fluorescent (XRF) scanning and proton induced x-ray emission (PIXE) techniques. XRF and PIXE are commonly used in the study of cultural heritage objects because they are nondestructive. The combination of these two methods is also unique because of the ability to penetrate the sample with a broader spectrum of depths and energies than either could achieve on its own. The coins are from a large span of Roman history and their analysis serves to follow the economic and political change of the era using the relative silver and copper contents in each sample. In addition to analyzing the samples, the study sought to compare these two common analysis techniques and to explore the use of a standard to examine any shortcomings in either of the methods. Data sets were compared and then adjusted to a calibration curve which was created from the analysis of a number of standard solutions. The concentrations of the standard solutions were confirmed using inductively coupled plasma spectroscopy. Through this we were able to assemble results which will progress the basis of understanding of PIXE and XRF techniques as well as increase the wealth of knowledge of Ancient Roman currency.

  3. Ion beam analysis of rubies and their simulants

    Energy Technology Data Exchange (ETDEWEB)

    Juncomma, U. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50202 (Thailand); Intarasiri, S., E-mail: saweat@gmail.com [Science and Technology Research Institute, Chiang Mai University, Chiang Mai 50202 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Bootkul, D. [Department of General Science (Gems and Jewelry), Faculty of Science, Srinakharinwirot University, Bangkok 10110 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Tippawan, U., E-mail: beary1001@gmail.com [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50202 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2014-07-15

    Ion beam analysis (IBA) is a set of well known powerful analytical techniques which use energetic particle beam as a probe. Among them, two techniques are suitable for gemological analysis, i.e., Particle Induced X-rays Emission (PIXE) and Ionoluminescence (IL). We combine these two techniques for the investigations of rubies and their simulants. The main objective is to find a reference fingerprint of these gemstones. The data are collected from several natural rubies, synthetic rubies, red spinels, almandine garnets and rubellite which very much resemble and are difficult to distinguish with the gemologist loupe. From our measurements, due to their different crystal structures and compositions, can be clearly distinguished by the IL and PIXE techniques. The results show that the PIXE spectra consist of a few dominant lines of the host matrix elements of each gemstone and some weaker lines due to trace elements of transition metals. PIXE can easily differentiate rubies from other stones by evaluating their chemical compositions. It is noticed that synthetic rubies generally contain fewer impurities, lower iron and higher chromium than the natural ones. Moreover, the IL spectrum of ruby is unique and different from those of others stones. The typical spectrum of ruby is centered at 694 nm, with small sidebands that can be ascribed to a Cr{sup 3+} emission spectrum which is dominated by an R-line at the extreme red end of the visible part of the electromagnetic spectrum. Although the spectrum of synthetic ruby is centered at the same wavelength, the peak is stronger due to higher concentration of Cr and lower concentration of Fe than for natural rubies. For spinel, the IL spectrum shows strong deformation where the R-line is split due to the presence of MgO. For rubellite, the peak center is shifted to 692 nm which might be caused by the replacement of Mn{sup 3+} at the Al{sup 3+} site of the host structure. It is noticed that almandine garnet is not luminescent due

  4. PIXE studies on elemental characterization of offset printing ink tagged with rare-earth taggants

    International Nuclear Information System (INIS)

    Joseph, D.; Saxena, A.; Choudhury, R.K.; Maind, S.D.

    2007-01-01

    Proton Induced X-ray Emission Technique (PIXE) has been used for elemental characterization of offset printing ink tagged with rare-earth taggants, with a proton beam of energy 4 MeV at Folded Tandem Ion Accelerator (FOTIA) at BARC, Trombay, Mumbai, India. The offset printing ink was tagged with rare-earth (La, Pr, Nd, Sm, Eu and Gd) thenoyltrifluoroacetonate chelates at about 1000 ppm level for each element separately. Small aliquots (approximately 20 mg) of tagged inks were coated on paper supports and then analyzed. Well-resolved rare-earth L X-rays were detected using a high resolution Si(Li) detector. Satisfactory results to identify and quantify the taggants were achieved. (author)

  5. Characteristics of ancient Egyptian glazed ceramic objects from Fatimid and Mamluk periods as revealed by ion beam analysis

    International Nuclear Information System (INIS)

    Sadek, Hamada; Abd El Hady M M

    2012-01-01

    Ion beam analysis (PIXE, μPIXE) has been successfully applied in analysis of archaeological materials, it has many advantages. In this work Ion Beam Analysis (IBA) used in analysis of ancient Egyptian glazed ceramic from 10th to the 16th centuries (Fatimid and Mamluk periods). Glazed ceramic samples from Al-Fustat Excavation store have been chosen to represent different colours (green, blue, brown, black ...etc), the colours of glaze depend on many factors such as oxides present in the glaze layer, fluxes and the conditions in which objects had been manufactured in the past. Ion Beam allows the identification of elemental composition of the glaze layer i.e., the information about colorants used in glaze, which is of great importance for compositional data play a key role in solving questions concerning dating, provenance, technology, use and the relationship between ancient cultures with the environment.

  6. Fish gelatin thin film standards for biological application of PIXE

    Science.gov (United States)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12C(p,p)12C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  7. Fish gelatin thin film standards for biological application of PIXE

    International Nuclear Information System (INIS)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-01-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12 C(p,p) 12 C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition

  8. Fish gelatin thin film standards for biological application of PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Manuel, Jack E., E-mail: jaelma@gmail.com [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Deaton, James; Luyombya, Henry [Louisiana Accelerator Center, University of Louisiana at Lafayette, Lafayette, LA 70503 (United States); Briski, Karen P. [Department of Basic Pharmaceutical Sciences, University of Louisiana at Monroe, Monroe, LA 71209 (United States); Glass, Gary A. [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States)

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon {sup 12}C(p,p){sup 12}C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  9. Pain flare following external beam radiotherapy and meaningful change in pain scores in the treatment of bone metastases

    International Nuclear Information System (INIS)

    Chow, Edward; Ling, Alison; Davis, Lori; Panzarella, Tony; Danjoux, Cyril

    2005-01-01

    Background and purpose: To examine the incidence of pain flare following external beam radiotherapy and to determine what constitutes a meaningful change in pain scores in the treatment of bone metastases. Patients and methods: Patients with bone metastases treated with external beam radiotherapy were asked to score their pain on a scale of 0-10 before the treatment (baseline), daily during the treatment and for 10 days after completion of external beam radiation. Pain flare was defined as a two-point increase from baseline pain in the pain scale of 0-10 with no decrease in analgesic intake or a 25% increase in analgesic intake employing daily oral morphine equivalent with no decrease in pain score. To distinguish pain flare from progression of pain, we required the pain score and analgesic intake to return back to baseline levels after the increase/flare. They were also asked to indicate if their pain changed during that time compared to pre-treatment level. The change in pain score was compared with patient perception. Results: Eighty-eight patients were evaluated in this study. There were 49 male and 39 female patients with the median age of 70 years. Twelve of 88 patients (14%) had pain flare on day 1. The overall incidence of pain flare during the study period ranged from 2 to 16%. A total of 797 pain scorings were obtained. Patients perceived an improvement in pain when their self-reported pain score decreased by at least two points. Conclusions: Our study confirms the occurrence of pain flare following the external beam radiotherapy in the treatment of bone metastases. Further studies are required to predict who are at risk for flare. Appropriate measures can be taken to alleviate the pain flare. The finding in the meaningful change in pain scores supports the investigator-defined partial response used in some clinical trials

  10. PIXE-quantified AXSIA: Elemental mapping by multivariate spectral analysis

    International Nuclear Information System (INIS)

    Doyle, B.L.; Provencio, P.P.; Kotula, P.G.; Antolak, A.J.; Ryan, C.G.; Campbell, J.L.; Barrett, K.

    2006-01-01

    Automated, nonbiased, multivariate statistical analysis techniques are useful for converting very large amounts of data into a smaller, more manageable number of chemical components (spectra and images) that are needed to describe the measurement. We report the first use of the multivariate spectral analysis program AXSIA (Automated eXpert Spectral Image Analysis) developed at Sandia National Laboratories to quantitatively analyze micro-PIXE data maps. AXSIA implements a multivariate curve resolution technique that reduces the spectral image data sets into a limited number of physically realizable and easily interpretable components (including both spectra and images). We show that the principal component spectra can be further analyzed using conventional PIXE programs to convert the weighting images into quantitative concentration maps. A common elemental data set has been analyzed using three different PIXE analysis codes and the results compared to the cases when each of these codes is used to separately analyze the associated AXSIA principal component spectral data. We find that these comparisons are in good quantitative agreement with each other

  11. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  12. PIXE and the mysteries of Legionnaires' disease

    International Nuclear Information System (INIS)

    Chen, J.R.

    1981-01-01

    The authors describe the use of proton-induced X-ray emission (PIXE) to analyse the nickel concentrations of the autopsy specimens from victims of Legionnaires' disease. They show that the high nickel concentrations in the lung specimens from the first recognized Legionnaires' cases in Philadelphia in 1976 were due to contamination during the autopsies. Recently the authors have used PIXE to show that the selenium concentrations in the sera of the acutely ill Legionnaires' patients are significantly lower than in their matching convalescent-phase sera. This finding may be related to the patient's response to the disease or to the specific characteristics of the Legionella pneumophila itself. Studies show that the disease is not a rare illness but a worldwide one. General criteria concerning specimen collection are described

  13. Holistic RBS-PIXE data reanalysis of SBT thin film samples

    International Nuclear Information System (INIS)

    Reis, M.A.; Barradas, N.P.; Pascual-Izarra, C.; Chaves, P.C.; Ramos, A.R.; Alves, E.; Gonzalez-Aguilar, G.; Costa, M.E.V.; Miranda Salvado, I.M.

    2007-01-01

    The growth of SrBi 2 Ta 2 O 9 (SBT) films on top of Pt electrode substrates is an important issue for the fabrication of ferroelectric based memories. In a recent publication, SBT thin films grown using seeded and unseeded procedures were studied by PIXE and RBS. Difficulties and misfits found in the comparison of results from both techniques were, at that time, overcome by physical considerations. These, although not rendering interpretation impossible, left out the possibility of understanding the exact nature of the differences between the interface behavior in each case. In the present work it is shown that the reanalysis of the same data using the recently developed RBS-PIXE simultaneous and self-consistent calculation present in NDF leads to stronger conclusions on the solid state reaction occurring during the deposition stage for both types of samples. Allowing for the occurrence of solid state reactions between the deposited film and the Pt electrode even in the case of seeded samples leads to a full explanation of IBA data, this result showing that in complex systems such as this, the PIXE data are essential and must be integrated with the RBS data in an holistic analysis, in order to properly unfold the depth profile of the samples. Contrary to what is usually supposed PIXE data is therefore shown to contain hidden depth structure information

  14. Combined external beam and intraluminal radiotherapy for irresectable Klatskin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Schleicher, U.M. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); Staatz, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Alzen, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Abt. Kinderradiologie, Giessen Univ. (Germany); Andreopoulos, D. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); BOC Oncology Centre, Nikosia (Cyprus)

    2002-12-01

    Background: In most cases of proximal cholangiocarcinoma, curative surgery is not possible. Radiotherapy can be used for palliative treatment. We report our experience with combined external beam and intraluminal radiotherapy of advanced Klatskin's tumors. Patients and Methods: 30 patients were treated for extrahepatic proximal bile duct cancer. Our schedule consisted for external beam radiotherapy (median dose 30 Gy) and a high-dose-rate brachytherapy boost (median dose 40 Gy) delivered in four or five fractions, which could be applied completely in twelve of our patients. 15 patients in the brachytherapy and nine patients in the non-brachytherapy group received additional low-dose chemotherapy with 5-fluorouracil. Results: The brachytherapy boost dose improved the effect of external beam radiotherapy by increasing survival from a median of 3.9 months in the non-brachytherapy group to 9.1 months in the brachytherapy group. The effect was obvious in patients receiving a brachytherapy dose above 30 Gy, and in those without jaundice at the beginning of radiotherapy (p<0.05). Conclusions: The poor prognosis in patients with advanced Klatskin's tumors may be improved by combination therapy, with the role of brachytherapy and chemotherapy still to be defined. Our results suggest that patients without jaundice should be offered brachytherapy, and that a full dose of more than 30 Gy should be applied. (orig.) [German] Hintergrund: Bei den meisten Patienten mit proximalen Cholangiokarzinomen ist eine kurative Operation nicht mehr moeglich. Im Rahmen der Palliativbehandlung kann die Strahlentherapie eingesetzt werden. Wir berichten ueber unsere Erfahrungen mit der Kombination aus perkutaner und intraluminaler Strahlentherapie fortgeschrittener Klatskin-Tumoren. Patienten und Methode: 30 Patienten wurden wegen extrahepatischer proximaler Gallengangskarzinome behandelt. Unser Therapieschema umfasste eine perkutane Strahlentherapie (mediane Dosis: 30 Gy) sowie einen

  15. Proton Induced X-Ray Emission (PIXE) Analysis to Measure Trace Metals in Soil Along the East River in Queens, New York

    Science.gov (United States)

    Chalise, Sajju; Conlan, Skye; Porat, Zachary; Labrake, Scott; Vineyard, Michael

    2017-09-01

    The Union College Ion-Beam Analysis Lab's 1.1 MV tandem Pelletron accelerator is used to determine the presence of heavy trace metals in Queens, NY between Astoria Park and 3.5 miles south to Gantry State Park. A PIXE analysis was performed on 0.5 g pelletized soil samples with a 2.2 MeV proton beam. The results show the presence of elements ranging from Ti to Pb with the concentration of Pb in Astoria Park (2200 +/-200 ppm) approximately ten times that of the Gantry State Park. We hypothesize that the high lead concentration at Astoria Park is due to the nearby Hell Gate Bridge, painted in 1916 with lead based paint, then sandblasted and repainted in the '90s. If the lead is from the repair of the bridge, then we should see the concentration decrease as we go further from the bridge. To test this, soil samples were collected and analyzed from seven different locations north and south of the bridge. The concentrations of lead decreased drastically within a 500 m radius and were approximately constant at greater distances. More soil samples need to be collected within the 500 m radius from bridge to identify the potential source of Pb. We will describe the experimental procedure, the PIXE analysis of soil samples, and present preliminary results on the distribution of heavy trace metals.

  16. PIXE analysis of umeboshi (dried plum)

    International Nuclear Information System (INIS)

    Tsuboi, S.; Ishii, K.; Matsuyama, S.

    2008-01-01

    In recent years, the self-sufficiency ratio of food in Japan has gradually decreased and 60% of foods are now imported from abroad. Japanese people rely strongly upon imported food and should take care of their safety, but what is happening now is that soil pollution in country of origin grows into a serious problem and can affect imported food. Umeboshi is one of the traditional pickled food in Japan and very popular. In the case of umeboshi, more than 65% of it is imported. We analyzed imported umeboshi and domestic ones by using in-air PIXE system and submili-PIXE camera at Tohoku University. In this experiment, the concentrations of toxic heavy metals such as As, Cd, Hg and Pb were lower than standard values given by a food hygiene law. Concentrations of elements heavier than Ca show similar trend among each sample. On the other hand, lighter elements than Ca show large differences, which is related to food coloring or processing technique. (author)

  17. Neural Stem Cell-Preserving External-Beam Radiotherapy of Central Nervous System Malignancies

    International Nuclear Information System (INIS)

    Barani, Igor J.; Cuttino, Laurie W.; Benedict, Stanley H.; Todor, Dorin; Bump, Edward A.; Wu Yan; Chung, Theodore D.; Broaddus, William C.; Lin, Peck-Sun

    2007-01-01

    Purpose: Recent discoveries have implicated neural stem cells (NSC) as the source of plasticity and repair in the mature mammalian brain. Treatment-induced NSC dysfunction may lead to observed toxicity. This study evaluates the feasibility of NSC-preserving external beam radiotherapy. Methods and Materials: A single computed tomography (CT) dataset depicting a right periventricular lesion was used in this study as this location reflects the most problematic geometric arrangement with respect to NSC preservation. Conventional and NSC preserving radiotherapy (RT) plans were generated for the same lesion using two clinical scenarios: cerebral metastatic disease and primary high-grade glioma. Disease-specific target volumes were used. Metastatic disease was conventionally treated with whole-brain radiotherapy (WBRT) to 3,750 cGy (15 fractions) followed by a single stereotactic radiosurgery (SRS) boost of 1,800 cGy to gross disease only. High-grade glioma was treated with conventional opposed lateral and anterior superior oblique beams to 4,600 cGy (23 fractions) followed by a 1,400 cGy (7 fractions) boost. NSC preservation was achieved in both scenarios with inverse-planned intensity modulated radiotherapy (IMRT). Results: Cumulative dose reductions of 65% (metastatic disease) and 25% (high-grade glioma) to the total volume of the intracranial NSC compartments were achieved with NSC-preserving IMRT plans. The reduction of entry and exit dose to NSC niches located contralateral to the target contributed most to NSC preservation. Conclusions: Neural stem cells preservation with current external beam radiotherapy techniques is achievable in context of both metastatic brain disease and high-grade glioma, even when the target is located adjacent to a stem cell compartment. Further investigation with clinical trials is warranted to evaluate whether NSC preservation will result in reduced toxicity

  18. Implementation of ionoluminescence in the AGLAE scanning external microprobe

    International Nuclear Information System (INIS)

    Pichon, L.; Calligaro, T.; Gonzalez, V.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The scope of this work is to present the implementation of an IBIL imaging system in the scanning external microprobe of the AGLAE facility so as to correlate luminescence and composition maps provided by PIXE, RBS and PIGE. The challenging integration of the optical spectrometer, due to incompatibility of acquisition timings and data formats with the other IBA channels has motivated the development of a specific acquisition system. This article details the IBIL setup and explains the technical solutions retained for the coupling of IBIL with IBA techniques in order to produce fast and large IBIL-IBA maps. The IBIL maps stored in the same format as the PIXE, RBS and PIGE ones can be visualised and compared using the dedicated AGLAEmap program or the PyMCA processing package. An example of such a coupled mapping on Mesoamerican jade is presented to emphasise the interest of performing simultaneously IBA and IBIL large mappings

  19. PIXE identification of fine and coarse particles of aerosol samples and their distribution across Beirut

    Energy Technology Data Exchange (ETDEWEB)

    Roumie, M., E-mail: mroumie@cnrs.edu.lb [Accelerator Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, P.O. Box 11-8281, Beirut (Lebanon); Saliba, N., E-mail: ns30@aub.edu.lb [Department of Chemistry, Faculty of Arts and Sciences, American University of Beirut, Beirut (Lebanon); Nsouli, B., E-mail: bnsouli@cnrs.edu.lb [Accelerator Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, P.O. Box 11-8281, Beirut (Lebanon); Younes, M., E-mail: myriam_younis@hotmail.com [Accelerator Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, P.O. Box 11-8281, Beirut (Lebanon); Noun, M., E-mail: manale_noun@hotmail.com [Accelerator Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, P.O. Box 11-8281, Beirut (Lebanon); Massoud, R., E-mail: rm84@aub.edu.lb [Department of Chemistry, Faculty of Arts and Sciences, American University of Beirut, Beirut (Lebanon)

    2011-12-15

    This study is the first national attempt to assess the levels of PMs in Beirut city and consequently understand air pollution distribution. Aerosol sampling was carried out using three PM{sub 10} and three PM{sub 2.5} samplers which were installed at three locations lying along the SE-NW direction over Beirut. The sampling of PM{sub 10} and PM{sub 2.5} was done during a period extending from May till December 2009. The random collection of the particles (1 in 6 days) was carried out on Teflon filters, for a period of 24-h. The elemental analysis of particulate matter was performed using proton induced X-ray emission technique PIXE at the Lebanese 1.7 MV Tandem-Pelletron accelerator of Beirut. Na, Mg, Al, Si, P, S and Cl were quantified using 1 MeV proton beam, while K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb were determined using 3 MeV-energy of proton beam.

  20. Differential PIXE for investigating the layer structure of paintings

    Science.gov (United States)

    Mandò, P. A.; Fedi, M. E.; Grassi, N.; Migliori, A.

    2005-09-01

    This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the "Madonna dei fusi" (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out.

  1. Differential PIXE for investigating the layer structure of paintings

    International Nuclear Information System (INIS)

    Mando, P.A.; Fedi, M.E.; Grassi, N.; Migliori, A.

    2005-01-01

    This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the 'Madonna dei fusi' (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out

  2. Development of sample preparation method for honey analysis using PIXE

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Chiba, Keiko; Sera, Koichiro

    2008-01-01

    We developed an original preparation method for honey samples (samples in paste-like state) specifically designed for PIXE analysis. The results of PIXE analysis of thin targets prepared by adding a standard containing nine elements to honey samples demonstrated that the preparation method bestowed sufficient accuracy on quantitative values. PIXE analysis of 13 kinds of honey was performed, and eight mineral components (Si, P, S, K, Ca, Mn, Cu and Zn) were detected in all honey samples. The principal mineral components were K and Ca, and the quantitative value for K accounted for the majority of the total value for mineral components. K content in honey varies greatly depending on the plant source. Chestnuts had the highest K content. In fact, it was 2-3 times that of Manuka, which is known as a high quality honey. K content of false-acacia, which is produced in the greatest abundance, was 1/20 that of chestnuts. (author)

  3. Radiobiological comparison of external beam irradiation and radioimmunotherapy in renal cell carcinoma xenografts

    International Nuclear Information System (INIS)

    Wessels, B.W.; Vessella, R.L.; Palme, D.F. II; Berkopec, J.M.; Smith, G.K.; Bradley, E.W.

    1989-01-01

    Growth delay was measured in TK-82 renal cell carcinoma (RCC) xenografts implanted in nude mice receiving single fraction external beam irradiation (SF-XRT), multifraction external beam irradiation (MF-XRT), or radioimmunotherapy (RIT). Thermoluminescent dosimeter(s) (TLD) and autoradiography were used to ascertain the average absorbed dose delivered and the degree of heterogeneous uptake of radiolabeled antibody for the RIT irradiations. For intravenous administered activities of 100, 200, 400, and 600 microCi of I-131 labeled A6H antibody, volume doubling times (VDT) and TLD absorbed dose measurements for each administered activity were 7 days (341 cGy), 38 days (383 cGy), 85 days (886 cGy) and no regrowth (1034 cGy), respectively. For SF-XRT irradiations of 500, 1000, and 1500 cGy, VDT times were 11, 62, and 103 days, respectively. MF-XRT of 4 X 250 cGy over a 2-week period yielded a VDT of 25 days. Marked peripheral activity deposition was noted on most autoradiographs from multiple tumor samples. These data suggest that an equivalent to superior tumor growth delay is obtained for absorbed doses delivered by exponentially decaying low dose rate radioimmunotherapy RIT compared to similar doses of acute dose rate XRT as quantitated by the TLD method

  4. Characterization and application of automated in-vacuum PIXE/EBS system for direct analysis of chloride and sulfate ions attack in cementitious materials

    Science.gov (United States)

    Rihawy, M. S.; Alwazzeh, M.; Abbas, K.

    2018-01-01

    Ion beam analysis (IBA) techniques (Particle Induced X-ray Emission, PIXE and Elastic Backscattering Spectrometry, EBS), were applied to investigate chloride and sulfate ions diffusion into laboratory prepared mortar samples. Development and characterization of an automated in-vacuum macro PIXE/EBS system is thoroughly discussed. Depth profile information of both chloride and sulfate ions in laboratory prepared mortar samples, after immersion in sea water for nine months, was rapidly and easily obtained at fairly low cost and with standardless analysis, demonstrating the value of the application of IBA to elemental depth profiling in cementitious materials. Chloride and sulfate depth profiles were obtained for two sets of mortar samples, one prepared with different water/cement (W/C) ratios and the other with different sand/cement (S/C) ratios. Results showed higher diffusion rates of both chloride and sulfate ions when both ratios are increased. Additionally, the W/C ratio has a stronger influence in both sulfate and chloride penetration than the S/C ratio, and chloride ions penetrate faster than sulfates. Advantages and limitations of applying IBA techniques in this investigation are discussed. The comparison between PIXE and other X-ray based analytical techniques, namely X-ray fluorescence (XRF) and energy and wavelength dispersive X-rays (EDX/WDX), as well as other traditional wet chemical methods is reviewed, and industrial applications are discussed.

  5. Proton induced X-ray emission (PIXE) analysis at Lucas Heights

    International Nuclear Information System (INIS)

    Cohen, D.; Duerden, P.

    1979-02-01

    The state of the proton induced X-ray emission (PIXE) work at Lucas Heights is reported together with a full description of the experimental arrangement and its use for analysis of trace elements (Z >or= 14). The fundamentals of PIXE are examined in detail with a view to understanding not only the background continuum but also the X-ray production mechanisms. Quantitative predictions for the number of X-rays detected after proton bombardment of the target have been made and these compare well with experiments

  6. Parallel processing of dose calculation for external photon beam therapy

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Ando, Yutaka; Tsukamoto, Nobuhiro; Ito, Hisao; Kubo, Atsushi

    1994-01-01

    We implemented external photon beam dose calculation programs into a parallel processor system consisting of Transputers, 32-bit processors especially suitable for multi-processor configuration. Two network conformations, binary-tree and pipeline, were evaluated for rectangular and irregular field dose calculation algorithms. Although computation speed increased in proportion to the number of CPU, substantial overhead caused by inter-processor communication occurred when a smaller computation load was delivered to each processor. On the other hand, for irregular field calculation, which requires more computation capability for each calculation point, the communication overhead was still less even when more than 50 processors were involved. Real-time responses could be expected for more complex algorithms by increasing the number of processors. (author)

  7. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  8. A forensic application of PIXE analysis

    International Nuclear Information System (INIS)

    Kravchenko, I.I.; Dunnam, F.E.; Rinsvelt, H.A. van; Warren, M.W.; Falsetti, A.B.

    2001-01-01

    PIXE measurements were performed on various calcareous materials including identified bone residues, human cremains, and samples of disputed origin. In a forensic application, the elemental analysis suggests that the origin of a sample suspectly classified as human cremains can tentatively be identified as a mixture of sandy soil and dolomitic limestone

  9. A comparison of protocols for external beam radiotherapy beam calibrations

    International Nuclear Information System (INIS)

    Saeed Al-Ahbabi, Salma; Bradley, D.A.; Beyomi, M.; Alkatib, Z.; Adhaheri, S.; Darmaki, M.; Nisbet, A.

    2012-01-01

    A number of codes of practice (CoP) for electron and photon radiotherapy beam dosimetry are currently in use. Comparison is made of the more widely used of these, specifically those of the International Atomic Energy Agency (IAEA TRS-398), the American Association of Physicists in Medicine (AAPM TG-51) and the Institute of Physics and Engineering in Medicine (IPEM 2003). All are based on calibration of ionization chambers in terms of absorbed dose to water, each seeking to reduce uncertainty in delivered dose, providing an even stronger system of primary standards than previous air-kerma based approaches. They also provide a firm, traceable and straight-forward formalism. Included in making dose assessments for the three CoP are calibration coefficients for a range of beam quality indices. Measurements have been performed using clinical photon and electron beams, the absorbed dose to water being obtained following the recommendations given by each code. Electron beam comparisons have been carried out using measurements for electron beams of nominal energies 6, 9, 12, 16 and 20 MeV. Comparisons were also carried out for photon beams of nominal energies 6 and 18 MV. For photon beams use was made of NE2571 cylindrical graphite walled ionization chambers, cross-calibrated against an NE2611 Secondary Standard; for electron beams, PTW Markus and NACP-02 plane-parallel chambers were used. Irradiations were made using Varian 600C/2100C linacs, supported by water tanks and Virtual Water™ phantoms. The absorbed doses for photon and electron beams obtained following these CoP are all in good agreement, with deviations of less than 2%. A number of studies have been carried out by different groups in different countries to examine the consistency of dosimetry codes of practice or protocols. The aim of these studies is to confirm that the goal of those codes is met, namely uniformity in establishment of dosimetry of all radiation beam types used in cancer therapy in the world

  10. Construction of a PIXE database for supporting PIXE studies. Database of experimental conditions and elemental concentration for various samples

    International Nuclear Information System (INIS)

    Itoh, J.; Saitoh, Y.; Futatsugawa, S.; Sera, K.; Ishii, K.

    2007-01-01

    A database of PIXE data, which have been accumulated at NMCC, has been constructed. In order to fill up the database, data are newly obtained as many as possible for the kind of samples whose number is small. In addition, the data for different measuring conditions are obtained for several samples. As the number of γ-ray spectrum obtained with a HPGe detector for the purpose of analyzing light elements such as fluorine, is overwhelmingly small in comparison with that of usual PIXE spectra, γ-ray spectrum and elemental concentration of fluorine are obtained as many as possible for food, environmental and hair samples. In addition, the data taken with an in-air PIXE system have been obtained for various samples. As a result, the database involving contents over various research fields is constructed, and it is expected to be useful for researches who make use of analytical techniques. It is expected that this work will give a start to many researchers to participate in the database and to make calibration with each other in order to establish reliable analytical techniques. Moreover, the final goal of the database is to establish the control concentration values for typical samples. As the first step of establishing the control values, average elemental concentration and its standard deviations in hair samples taken from 405 healthy Japanese are obtained and tabulated according to their sex and age. (author)

  11. Limited angle STIM and PIXE tomography of single cells

    International Nuclear Information System (INIS)

    Andrea, T.; Rothermel, M.; Werner, R.; Butz, T.; Reinert, T.

    2010-01-01

    STIM (scanning transmission ion microscopy) tomography has been shown to be a valuable method for the three-dimensional characterization of microsamples. It has, however, rarely been employed for the study of single cells, since a free-standing sample is needed for an ordinary tomography experiment. This requirement places high demands on sample preparation techniques. In this study cells fixated on a substrate rather than free-standing were used for tomography. Since the substrate prevented a full rotation of the sample an algorithm for limited-angle tomography was devised. STIM projections covering only a limited angular range of ca. 120 o were supplemented with simulated projections generated from a back and forth iteration between real space and Radon space. The energy loss caused by the substrate was subtracted from each projection. The cells were reconstructed using filtered backprojection. The surface of the cells as well as some interior structures could be reconstructed. Following the STIM projections a lesser number of PIXE (particle induced X-ray emission) projections were taken in order to obtain information about the elemental distribution of the sample. From the PIXE projections the three-dimensional phosphorus distribution within the cell was reconstructed using limited-angle tomography. Superimposition of the STIM and PIXE tomograms revealed the location of intracellular structures. Whereas STIM tomography is sensitive to density contrast, which are greatest at the surface, PIXE tomography is sensitive to changes in elemental concentration. Hence, the combination of the two methods can be very fruitful, while the limited angle approach can compensate some of the difficulties associated with tomography of single cells, namely preparation difficulties and excessive sample damage.

  12. Prostate biopsy after definitive treatment by interstitial iodine 125 implant or external beam radiation therapy

    International Nuclear Information System (INIS)

    Schellhammer, P.F.; el-Mahdi, A.M.; Higgins, E.M.; Schultheiss, T.E.; Ladaga, L.E.; Babb, T.J.

    1987-01-01

    The response to definitive radiation therapy of localized carcinoma of the prostate by iodine 125 implantation or external beam radiotherapy was monitored by examining specimens from biopsies performed after treatment. We analyzed 126 biopsy specimens obtained 18 months or more after treatment: 71 were obtained from 109 patients treated by iodine 125 and 55 from 197 patients treated by external beam radiotherapy. Thereafter, the disease status of these patients was examined at minimum 3-year intervals. No significant statistical difference was found between the negative specimen rates of the 2 treatment modalities: 46 of 71 (65 per cent) after iodine 125 implantation and 39 of 55 (71 per cent) after external beam radiotherapy were negative. To analyze the predictive value of biopsy results 103 patients whose prostatic examination results were normal at biopsy or who showed regression of tumor size and tumor induration after radiation were evaluated. The biopsy results from all patients were combined for analysis. Of 77 patients with negative biopsy specimens 16 (21 per cent) have had recurrent disease, compared to 17 of 26 (65 per cent) with positive biopsy specimens (p equals 0.00005). Of the 77 patients with negative biopsy specimens 7 (9 per cent) had local disease recurrence, compared to 12 of 26 (46 per cent) with a positive biopsy specimen (p equals 0.0001). The value of a positive specimen to predict failure remained significant with patients stratified by pre-treatment clinical stage and grade of the disease. Our results show that patients with positive specimens from the prostate who had been judged clinically by rectal examination to have responded to radiation therapy had a significantly increased incidence of local and distant failure compared to patients who had negative biopsy specimens

  13. Evaluation of the Induced Activity in Air by the External Proton Beam in the Target Room of the Proton Accelerator Facility of Proton Engineering Frontier Project

    International Nuclear Information System (INIS)

    Lee, Cheol Woo; Lee, Young Ouk; Cho, Young Sik; Ahn, So Hyun

    2007-01-01

    One of the radiological concerns is the worker's exposure level and the concentration of the radionuclides in the air after shutdown, for the safety analysis on the proton accelerator facility. Although, the primary radiation source is the protons accelerated up to design value, all of the radio-nuclide is produced from the secondary neutron and photon induced reaction in air. Because, the protons don't penetrate the acceleration equipment like the DTL tank wall or BTL wall, secondary neutrons or photons are only in the air in the accelerator tunnel building because of the short range of the proton in the materials. But, for the case of the target rooms, external proton beams are occasionally used in the various experiments. When these external proton beams travel through air from the end of the beam transport line to the target, they interact directly with air and produce activation products from the proton induced reaction. The external proton beam will be used in the target rooms in the accelerator facility of the Proton Accelerator Frontier Project (PEFP). In this study, interaction characteristics of the external proton beam with air and induced activity in air from the direct interaction of the proton beam were evaluated

  14. Accelerator mass spectrometry at the Rossendorf 5 MV tandem accelerator

    International Nuclear Information System (INIS)

    Friedrich, M.; Buerger, W.; Curian, H.; Hartmann, B.; Hentschel, E.; Matthes, H.; Probst, W.; Seidel, M.; Turuc, S.; Hebert, D.; Rothe, T.; Stolz, W.

    1992-01-01

    The Rossendorf electrostatic accelerators (5 MV tandem accelerator and single ended 2 MV van de Graaff accelerator) are already used for ion beam analysis. The existing methods (RBS, PIXE, ERDA, NRA, nuclear microprobe and external beam) will be completed by introduction of Accelerator Mass Spectrometry (AMS). A short description of the Rossendorf AMS system is given and first experimental results are presented. (R.P.) 4 refs.; 6 figs

  15. Parameter determination for quantitative PIXE analysis using genetic algorithms

    International Nuclear Information System (INIS)

    Aspiazu, J.; Belmont-Moreno, E.

    1996-01-01

    For biological and environmental samples, PIXE technique is in particular advantage for elemental analysis, but the quantitative analysis implies accomplishing complex calculations that require the knowledge of more than a dozen parameters. Using a genetic algorithm, the authors give here an account of the procedure to obtain the best values for the parameters necessary to fit the efficiency for a X-ray detector. The values for some variables involved in quantitative PIXE analysis, were manipulated in a similar way as the genetic information is treated in a biological process. The authors carried out the algorithm until they reproduce, within the confidence interval, the elemental concentrations corresponding to a reference material

  16. Radiation optic neuropathy after external beam radiation therapy for acromegaly: report of two cases

    International Nuclear Information System (INIS)

    Bergh, Alfons C.M. van den; Hoving, Marjanke A.; Links, Thera P.; Dullaart, Robin P.F.; Ranchor, Adelita V.; Weeme, Cees A. ter; Canrinus, Alof A.; Szabo, Ben G.; Pott, Jan-Willem R.

    2003-01-01

    For diagnosing radiation optic neuropathy (RON) ophthalmological and imaging data were evaluated from 63 acromegalic patients, irradiated between 1967 and 1998. Two patients developed RON: one patient in one optic nerve 10 years and another patient in both optic nerves 5 months after radiation therapy. RON is a rare complication after external beam radiation therapy for acromegaly, which can occur after a considerable latency period

  17. External cervical resorption: an analysis using cone beam and microfocus computed tomography and scanning electron microscopy.

    Science.gov (United States)

    Gunst, V; Mavridou, A; Huybrechts, B; Van Gorp, G; Bergmans, L; Lambrechts, P

    2013-09-01

    To provide a three-dimensional representation of external cervical resorption (ECR) with microscopy, stereo microscopy, cone beam computed tomography (CT), microfocus CT and scanning electron microscopy (SEM). External cervical resorption is an aggressive form of root resorption, leading to a loss of dental hard tissues. This is due to clastic action, activated by a damage of the covering cementum and stimulated probably by infection. Clinically, it is a challenging situation as it is characterized by a late symptomatology. This is due to the pericanalar protection from a resorption-resistant sheet, composed of pre-dentine and surrounding dentine. The clastic activity is often associated with an attempt to repair, seen by the formation of osteoid tissue. Cone beam CT is extremely useful in the diagnoses and treatment planning of ECR. SEM analyses provide a better insight into the activity of osteoclasts. The root canal is surrounded by a layer of dentine that is resistant to resorption. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. Compositional studies on Transylvanian gold nuggets: Advantages and limitations of PIXE-PIGE analysis

    International Nuclear Information System (INIS)

    Bugoi, Roxana; Cojocaru, Viorel; Constantinescu, Bogdan; Calligaro, Thomas; Pichon, Laurent; Roehrs, Stefan; Salomon, Joseph

    2008-01-01

    Minute fragments from nine gold nuggets from Transylvania - two belonging to placer deposits and seven to primary deposits - were analyzed by PIXE and PIGE at the AGLAE tandem accelerator of the Centre de Recherche et de Restauration des Musees de France (C2RMF) with a 3 MeV proton beam extracted into air. This study was triggered by some archaeological provenance issues for which the elemental characterization of the Transylvanian gold source, exploited from the Antiquity, was required. All analyzed Transylvanian gold nuggets are characterized by a consistently high amount of Ag (18% on average). Au and Ag add up to roughly 99%, the other elements - Cu, Fe, Te, Pb - being detected only at a trace level. The obtained results are in good agreement with the previous analyses of Transylvanian gold

  19. PIXE analysis of human stones: comparison with data from ICP-AES

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.; Peisach, M.; Pineda, C.A.; Rodgers, A.L.

    1987-01-01

    25 human stone samples previously analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the IAEA Animal Bone Standard Reference Material were used to evaluate trace element analysis by PIXE. Bombardment with 4 MeV protons was used for the determination of Mn, Fe, Cu, Pb, Br, Rb, Sr and Ca. PIXE and ICP-AES data gave correlation factors better than 0.97 for the elements Ca, Fe, Zn, Sr and Pb. (author) 9 refs.; 5 figs

  20. LibCPIXE: A PIXE simulation open-source library for multilayered samples

    International Nuclear Information System (INIS)

    Pascual-Izarra, C.; Barradas, N.P.; Reis, M.A.

    2006-01-01

    Most particle induced X-ray emission (PIXE) data analysis codes are not focused on handling multilayered samples. We have developed an open-source library called 'LibCPIXE', for PIXE data analysis. It is written in standard C and implements functions for simulating X-ray yields of PIXE spectra taken from arbitrary samples, including multilayered targets. The library is designed to be fast, portable, modular and scalable, as well as to facilitate its incorporation into any existing program. In order to demonstrate the capabilities of the library, a program called CPIXE was developed and used to analyze various real samples involving both bulk and layered samples. Just as the library, the CPIXE source code is freely available under the General Public License. We demonstrate that it runs both under GNU/Linux systems as well as under MS Windows. There is in principle no limitation to port it to other platforms

  1. The new dedicated PIXE set-up at the National Environmental Research Institute, Denmark

    International Nuclear Information System (INIS)

    Kemp, Ka ring re; Waahlin, Peter

    1999-01-01

    The Niels Bohr Institute in Copenhagen was in the beginning of the 70'es one of the early places for PIXE. Contributions were made to the theoretical interpretation of the PIXE spectra as well as the practical application. The home-made 4 MV van de Graaff accelerator at the Niels Bohr Institute was an excellent tool for PIXE. The accelerator, which was used for many years, has now found its place on a museum after more than 40 years of active service. A dedicated PIXE set-up has now been established at the National Environmental Research Institute using a new 1.7 MV Tandem Pelletron (5SDH) from NEC. The main application is elemental analysis of outdoor aerosols. The main work is unsophisticated macro analyses, which do not push the equipment to its limits. This enables automated analysis of about 10,000 samples per year using very limited manpower resources. The research focuses on the contribution from various source types to the atmosphere over Europe, the North Atlantic and Greenland. Source compositions and their temporal variations are studied

  2. Application of micro-PIXE technique to uptake study of cesium by Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ohnuki, Toshihiko; Sakamoto, Fuminori; Kozai, Naofumi; Ozaki, Takuo; Narumi, Issei; Francis, Arokiasamy J.; Iefuji, Haruyuki; Sakai, Takuro; Kamiya, Tomihiro; Satoh, Takahiro; Oikawa, Masakazu

    2003-01-01

    We examined the accumulation and distribution of Cs, and the presence of other elements in yeast (Saccharomyces cerevisiae) cells by the micro-PIXE (particle induced X-ray emission) system developed at the TIARA facility, JAERI, and by energy dispersive spectroscopy (EDS) coupled to a scanning electron microscope. The effects of Cs on yeast growth were determined by measuring the optical density at 600 nm. Addition of 1 mM Cs did not have any effect on the growth of the yeast. Micro-PIXE analysis of cells grown in the presence of Cs showed that Cs was uniformly distributed in the cells. Using PIXE, Cs, P, K and Fe can be detected, whereas only P and S can be determined by the EDS. Cells exposed to Cs showed an increase in Cs peak intensity, and decrease in P, K and Fe with time. These results suggest that micro-PIXE is a useful technique to detect low concentration of toxic elements in microorganisms as well as to monitor their changes as function of growth

  3. Muscle invasive bladder cancer treated by transurethral resection, followed by external beam radiation and interstitial iridium-192

    NARCIS (Netherlands)

    A. Wijnmaalen (Arendjan); P.A. Helle (Peter); P.C.M. Koper (Peter); P.P. Jansen (Peter); P. Hanssens (Patrick); C.G.G. Boeken Kruger (Cornelis); W.L.J. van Putten (Wim)

    1997-01-01

    textabstractPurpose: To evaluate the results of transurethral resection (TUR), external beam radiotherapy (EBRT), and interstitial radiation (IRT) with iridium-192, using the afterloading technique in patients with muscle invasive bladder cancer. Methods and Materials: From May 1989 until September

  4. A novel preconcentration technique for the PIXE analysis of water

    International Nuclear Information System (INIS)

    Savage, J.M.; Robertson, J.D.; Majidi, V.

    1994-01-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. 5 mg of dried algae powder were mixed with 5 mL of single- and multi-metal solutions. The algae cells were then collected by filtration on 0.6 um polycarbonate membranes and analyzed by PIXE using a dual energy irradiation. When C. vulgatis was used on mixed metal solutions, linear responses were observed for Ag + , Ba 2+ , and Cd 2+ in the concentration range from 10 ng/g to 1 ug/g; for Cu 2+ and Pb 2+ from 10 ng/g to 5 ug/g; and for Hg 2+ from 10 ng/g to 10 ug/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 ug/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium is also replaced

  5. Environmental applications of PIXE at the Institute of Physics, UNAM

    International Nuclear Information System (INIS)

    Solis, C.; Mireles, A.; Andrade, E.; Zolezzi R, H.

    2007-01-01

    The particle induced X-ray emission technique (PIXE), developed by Johansson and colleagues in Lund, Sweden, in the 70's has been used since then in a high number of studies requiring detection and quantification of trace elements at high sensitivity (better than I mg/kg). PIXE is grouped among the nuclear analytical techniques because the samples are bombarded with particles (protons generally) accelerated in an accelerator. When protons interact with matter an X-Ray spectrum is produced by the deexcitation of atoms in the sample. From this spectrum the elements contained in the sample as well as their concentrations can be determined. In this work we describe the PIXE technique and several applications in the environmental field developed at the Institute of Physics of the National Autonomous University of Mexico (IFUNAM). These practical applications include field studies for analyses of suspended particles in air using tree leaves, irrigation water quality based on heavy metal analyses, and analyses of trace elements in plants cultivated in waste water irrigated soil. (Author)

  6. X-ray emission as a diagnostic from pseudospark-sourced electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Bowes, D., E-mail: david.bowes@strath.ac.uk [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Yin, H.; He, W.; Zhang, L.; Cross, A.W.; Ronald, K.; Phelps, A.D.R. [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Chen, D.; Zhang, P. [Computed Tomography Lab, School of Mathematical Sciences, Capital Normal University, Beijing 100048 (China); Chen, X.; Li, D. [Department of Electronic Engineering, Queen Mary University of London, London E1 4NS (United Kingdom)

    2014-09-15

    X-ray emission has been achieved using an electron beam generated by a pseudospark low-pressure discharge and utilised as a diagnostic for beam detection. A 300 A, 34 kV PS-sourced electron beam pulse of 3 mm diameter impacting on a 0.1 mm-thick molybdenum target generated X-rays which were detected via the use of a small, portable X-ray detector. Clear X-ray images of a micro-sized object were captured using an X-ray photodetector. This demonstrates the inducement of proton induced X-ray emission (PIXE) not only as an indicator of beam presence but also as a future X-ray source for small-spot X-ray imaging of materials.

  7. PIXE studies of osteoporosis preventive treatments

    International Nuclear Information System (INIS)

    Ynsa, M.D.; Pinheiro, T.; Ager, F.J.; Alves, L.C.; Millan, J.C.; Gomez-Zubelbia, M.A.; Respaldiza, M.A.

    2002-01-01

    Particle induced X-ray emission (PIXE) and nuclear microprobe (NMP) have been used in an exploratory work to study elemental alterations in tissues of experimental animals submitted to osteoporosis preventive treatments. Osteopathologies have been associated with several factors, such as hormonal disturbances, metabolic aberrations, low dietary Ca and vitamin D intake, excess of iron, among other possible factors. Hormonal treatments seem to be beneficial to the incorporation of Ca in bone but breast and endometrial cancers constitute significant side effects that cannot be ignored. Wistar female rats were used to test the effect of estrogen therapy in osteoporosis progression. The variations of elemental concentrations in uterus and the Ca content of femoral bones of ovariectomised rats under estrogen therapy were investigated. PIXE, Rutherford backscattering spectrometry and secondary electron microscopy techniques were applied for the characterisation of biological materials, with respect to morphology and trace element distribution determination. The increase of Ca and Fe concentrations in uterus and the variations for Ca distribution patterns in bone of rats submitted to estrogen therapy were the major features observed

  8. In situ analysis of human teeth by external PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Rautray, Tapash R., E-mail: tapash77@hotmail.co [Department of Dental Biomaterials, School of Dentistry, Kyungpook National University, 2-188-1 Samduk-dong, Jung-gu, Daegu (Korea, Republic of); ARASMIN, G. Udayagiri, Kandhamal, Orissa 762100 (India); Das, Saubhagyalaxmi [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005 (India); Rautray, Alekh C. [ARASMIN, G. Udayagiri, Kandhamal, Orissa 762100 (India)

    2010-07-15

    The elemental profiles of the enamel, cementum and caries of human teeth were analysed by the external proton induced X-ray emission studies. Ten elements namely P, Ca, V, Mn, Fe, Cu, Zn, As, Sr and Pb were estimated in the present study. P and Ca were found to be the major elements whereas all other elements were found in trace level. It was observed that the respective concentrations of elements namely P, Ca, Fe, Zn and Pb in enamel are more than those in cementum. Concentration of P ranged between 6.37% and 25% whereas Ca ranged between 12.94% and 43.36%.

  9. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    Science.gov (United States)

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  10. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  11. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    Directory of Open Access Journals (Sweden)

    D.D. Lestiani

    2011-08-01

    Full Text Available Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA and particles induced X-ray emission (PIXE. Particle samples in the PM2.5 and PM2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preffered, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment.

  12. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    International Nuclear Information System (INIS)

    Lestiani, D.D.; Santoso, M.

    2011-01-01

    Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA) and particles induced X-ray emission (PIXE). Particle samples in the PM 2.5 and PM 2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preferred, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment. (author)

  13. Tumor bed delineation for external beam accelerated partial breast irradiation: A systematic review

    International Nuclear Information System (INIS)

    Yang, T. Jonathan; Tao, Randa; Elkhuizen, Paula H.M.; Vliet-Vroegindeweij, Corine van; Li, Guang; Powell, Simon N.

    2013-01-01

    In recent years, accelerated partial breast irradiation (APBI) has been considered an alternative to whole breast irradiation for patients undergoing breast-conserving therapy. APBI delivers higher doses of radiation in fewer fractions to the post-lumpectomy tumor bed with a 1–2 cm margin, targeting the area at the highest risk of local recurrence while sparing normal breast tissue. However, there are inherent challenges in defining accurate target volumes for APBI. Studies have shown that significant interobserver variation exists among radiation oncologists defining the lumpectomy cavity, which raises the question of how to improve the accuracy and consistency in the delineation of tumor bed volumes. The combination of standardized guidelines and surgical clips significantly improves an observer’s ability in delineation, and it is the standard in multiple ongoing external-beam APBI trials. However, questions about the accuracy of the clips to mark the lumpectomy cavity remain, as clips only define a few points at the margin of the cavity. This paper reviews the techniques that have been developed so far to improve target delineation in APBI delivered by conformal external beam radiation therapy, including the use of standardized guidelines, surgical clips or fiducial markers, pre-operative computed tomography imaging, and additional imaging modalities, including magnetic resonance imaging, ultrasound imaging, and positron emission tomography/computed tomography. Alternatives to post-operative APBI, future directions, and clinical recommendations were also discussed

  14. PIXE analysis of exhaust gas from diesel engine

    International Nuclear Information System (INIS)

    Miyake, Hirosi; Michijima, Masami; Onishi, Masayuki; Fujitani, Tatsuya.

    1986-01-01

    The variation of elemental concentrations in exhaust gas of a Diesel engine with the outputs was studied. Particulates in high temperature gas were collected on silica fiber filters and analyzed by PIXE method. Concentrations of S and V were nearly proportional to particulate masses and fuel consumption rates per discharging rates of exhaust gas respectively. While, concentrations of Fe and Mn were markedly increased together with engine outputs, and Mn/Fe ratios were nearly equal to those of the material of piston rings and the cylinder liner. Concentrations of the elements contained in lubricant, such as Ca and Mo, were also conspicuously increased with the outputs. It was shown that PIXE analysis is a useful tool for engine diagonostics owing to its high sensitive multi-elemental availability without chemical treatments. (author)

  15. PIXE in 1980: Summary of the second international conference on particle induced x-ray emission and its analytical applications

    International Nuclear Information System (INIS)

    Akselsson, K.R.

    1981-01-01

    The Second International Conference on Particle Induced X-ray Emission (PIXE) and its analytical applications was held in Lund, Sweden, June 9-12, 1980. About a hundred papers were presented, including seven invited talks (PIXE and particle scattering, microbeam analysis, applications to aerosols and biological samples). The main impression left by the conference was that both the PIXE method and its applications are in a phase of fast development. Considerable effort has successfully been devoted to optimizing the basic PIXE technique. Also the great advantage of simultaneously getting information about lighter elements and sample mass was reported to have been successfully employed in routine analyses. PIXE, which was initially considered to be a method mainly for thin samples, has also been shown to be competitive for a variety of thick samples. Data from aerosol studies was presented. With the PIXE-method, it is feasible to perform series of measurements over a long period of time, many samples in parallel and/or samples from sites of poor accessibility. However, the advantages of PIXE may be further exploited in aerosol investigations and some promising lines of sampler development were reported. Sample preparation techniques are crucial for applications to biological samples and several laboratories are engaged in such developmental work. However, it was also evident that PIXE is already giving significant contributions to research in biology and medicine

  16. An ASEAN Ion Beam Analysis Center at Chiang Mai University, Thailand

    International Nuclear Information System (INIS)

    Tippawan, U.; Kamwann, T.; Yu, L.D.; Intarasiri, S.; Puttaraksa, N.; Unai, S.; Thongleurm, C.; Singkarat, S.

    2014-01-01

    To contribute to the development of nuclear science and technology in Thailand, a comprehensive ion beam analysis center unique in the ASEAN region has recently been established at Chiang Mai University, Thailand. The center is equipped with a 1.7-MV Tandetron tandem accelerator with an ion beam analysis beam line. The beam line is currently capable of performing ion beam analysis techniques such as Rutherford Backscattering Spectrometry (RBS), RBS/channeling, Elastic BackScattering (EBS), Particle Induced X-ray Emission (PIXE) and Ionoluminescence (IL) with assistance of commercial and in-house-developed softwares. Micro ion beam for MeV-ion mapping using programmable aperture or capillary focusing techniques is being developed. Ion beam analysis experiments and applications have been vigorously developed, especially for novel materials analysis focused on archeological, gemological and biological materials besides other conventional materials.

  17. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    International Nuclear Information System (INIS)

    Samea, Renato; Lourenco, Laercio Gomes

    2011-01-01

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  18. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Samea, Renato; Lourenco, Laercio Gomes, E-mail: renatosamea@globo.com [Department of Surgical Oncology of Dr. Arnaldo Vieira de Carvalho Hospital, Sao Paulo, SP (Brazil)

    2011-10-15

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  19. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  20. Composition of Renaissance paint layers: simultaneous particle induced X-ray emission and backscattering spectrometry.

    Science.gov (United States)

    de Viguerie, L; Beck, L; Salomon, J; Pichon, L; Walter, Ph

    2009-10-01

    Particle induced X-ray emission spectroscopy (PIXE) is now routinely used in the field of cultural heritage. Various setups have been developed to investigate the elemental composition of wood/canvas paintings or of cross-section samples. However, it is not possible to obtain information concerning the quantity of organic binder. Backscattering spectrometry (BS) can be a useful complementary method to overcome this limitation. In the case of paint layers, PIXE brings the elemental composition (major elements to traces) and the BS spectrum can give access to the proportion of pigment and binder. With the use of 3 MeV protons for PIXE and BS simultaneously, it was possible to perform quantitative analysis including C and O for which the non-Rutherford cross sections are intense. Furthermore, with the use of the same conditions for PIXE and BS, the experiment time and the potential damage by the ion beam were reduced. The results obtained with the external beam of the Accélérateur Grand Louvre pour l'Analyse Elementaire (AGLAE) facility on various test painting samples and on cross sections from Italian Renaissance masterpieces are shown. Simultaneous combination of PIXE and BS leads to a complete characterization of the paint layers: elemental composition and proportion of the organic binder have been determined and thus provide useful information about ancient oil painting recipes.

  1. Micro-PIXE studies of char populations in northern Canada

    International Nuclear Information System (INIS)

    Campbell, J.L.; Babaluk, J.A.; Halden, N.M.; Kristofferson, A.H.; Maxwell, J.A.; Mejia, S.R.; Reist, J.D.; Teesdale, W.J.

    1999-01-01

    Micro-PIXE analysis of trace elements in otoliths has been used as the basis for several projects on char, a fish that is important for aboriginal subsistence fisheries in Arctic Canada. Life-history patterns were originally inferred from micro-PIXE line scans of Sr distribution. These were confirmed by superposition of Sr distribution patterns on optical images of otoliths of tag-recaptured fish. Char from various populations showed differentiation in otolith primordial Sr concentration; this enables us to differentiate biological stocks and, it is hoped, eventually to assign individuals from mixed-stock fisheries to their stock of origin. Zn oscillations also correlate with annular structure and provide additional temporally constrained information on fish habitat and behaviour

  2. Parametric oesophageal multiple swallow scintigraphy for validation of dysphageal symptoms during external beam irradiation of mediastinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Brandt-Mainz, K.; Eising, E.G.; Bockisch, A. [Essen Univ. (Gesamthochschule) (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Mallek, D. von; Poettgen, C.; Stuschke, M.; Sack, H. [Klinik und Poliklinik fuer Strahlentherapie, Universitaetsklinikum Essen (Germany)

    2001-03-01

    The aim of the study was to evaluate dysphageal symptoms and to measure the effect of local analgesic treatment using parametric oesophageal multiple swallow scintigraphy (PES) during external beam irradiation of the mediastinal region. Fifteen patients (most with lung cancer) with dysphagia grade II underwent PES during external beam radiotherapy of the mediastinum before and after application of local analgesics. Dynamic parametric condensed images were recorded. The intensity of clinical symptoms was correlated with the emptying rate at 10 s (ER-10 s) and the mean transit time (MTT). Visual analysis of the images was performed and the results were correlated with the fields of irradiation portals. Of the 15 patients, 12 showed a correlation between irradiation portals and the region of oesophageal motility disorder. Concordant results of clinical symptoms and PES data were found. In nine patients with a decrease in dysphagia following local analgesia, an increase in mean ER-10 s and a decrease in MTT were observed. In three patients with deterioration in clinical symptoms after analgesic treatment, a similar decrease in mean ER-10 s was found, though MTT remained constant. In three patients with normal values, motility disorders were detected in the dynamic study. In conclusion, PES was found to be a sensitive tool for the validation of dysphageal symptoms in patients during external beam irradiation of mediastinal tumours and for the evaluation and quantification of the efficacy of local analgesic treatment. Additional visual analysis of the dynamic study is helpful in diagnosing minimal disorders. (orig.)

  3. Parametric oesophageal multiple swallow scintigraphy for validation of dysphageal symptoms during external beam irradiation of mediastinal tumours

    International Nuclear Information System (INIS)

    Brandt-Mainz, K.; Eising, E.G.; Bockisch, A.

    2001-01-01

    The aim of the study was to evaluate dysphageal symptoms and to measure the effect of local analgesic treatment using parametric oesophageal multiple swallow scintigraphy (PES) during external beam irradiation of the mediastinal region. Fifteen patients (most with lung cancer) with dysphagia grade II underwent PES during external beam radiotherapy of the mediastinum before and after application of local analgesics. Dynamic parametric condensed images were recorded. The intensity of clinical symptoms was correlated with the emptying rate at 10 s (ER-10 s) and the mean transit time (MTT). Visual analysis of the images was performed and the results were correlated with the fields of irradiation portals. Of the 15 patients, 12 showed a correlation between irradiation portals and the region of oesophageal motility disorder. Concordant results of clinical symptoms and PES data were found. In nine patients with a decrease in dysphagia following local analgesia, an increase in mean ER-10 s and a decrease in MTT were observed. In three patients with deterioration in clinical symptoms after analgesic treatment, a similar decrease in mean ER-10 s was found, though MTT remained constant. In three patients with normal values, motility disorders were detected in the dynamic study. In conclusion, PES was found to be a sensitive tool for the validation of dysphageal symptoms in patients during external beam irradiation of mediastinal tumours and for the evaluation and quantification of the efficacy of local analgesic treatment. Additional visual analysis of the dynamic study is helpful in diagnosing minimal disorders. (orig.)

  4. Minimal requirements for quality controls in radiotherapy with external beams; Controlli di qualita' essenziali in radioterapia con fasci esterni

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy. [Italian] Il gruppo di studio Assicurazione di qualita' in radioterapia dell'Istituto Superiore di Sanita' presenta le linee guida per la stesura dei protocolli di controllo di qualita' essenziali necessari a garantire un adeguato livello di accuratezza del trattamento radiante e rappresenta pertanto una parte essenziale del contributo fisico-dosimetrico globale di assicurazione di qualita' in radioterapia con fasci esterni.

  5. Analysis of bone marrow stromal cell transferred bacterial {beta}-galactosidase gene by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Toshiro [Tokyo Metropolitan Geriatric Hospital, Tokyo (Japan). Dept. of Blood Transfusion and Hematology; Hibino, Hitoshi; Tani, Kenzaburo; Asano, Shigetaka; Futatugawa, Shouji; Sera, Kouichiro

    1997-12-31

    PIXE, Particle Induced X-ray Emission, is a powerful, multi-elemental analysis method which has many distinguishing features and has been used in varies research fields. Recently the method of applying baby cyclotrons for nuclear medicine to PIXE has been developed. This enables us to study biomedical phenomena from the physical point of view. Mouse bone marrow stromal cells were transferred bacterial {beta}-galactosidase gene (LacZ gene) by murine retroviral vectors. Analysis of the bone marrow stromal cells with the LacZ gene by PIXE revealed remarkable changes of intracellular trace elements compared with the normal control cells. These results indicate that gene transfer by retroviral vectors may bring about a dynamic change of intracellular circumstances of the target cell. (author)

  6. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    International Nuclear Information System (INIS)

    Sole, C.V.; Calvo, F.A.; Lozano, M.A.; Gonzalez-Sansegundo, C.; Gonzalez-Bayon, L.; Alvarez, A.; Lizarraga, S.; Garcia-Sabrido, J.L.

    2014-01-01

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  7. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    Energy Technology Data Exchange (ETDEWEB)

    Sole, C.V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Calvo, F.A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lozano, M.A.; Gonzalez-Sansegundo, C. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Gonzalez-Bayon, L. [Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Alvarez, A. [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lizarraga, S. [Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Garcia-Sabrido, J.L. [Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain)

    2014-02-15

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  8. Adjuvant external beam radiotherapy in the treatment of endometrial cancer (MRC ASTEC and NCIC CTG EN.5 randomised trials): pooled trial results, systematic review, and meta-analysis.

    Science.gov (United States)

    Blake, P; Swart, Ann Marie; Orton, J; Kitchener, H; Whelan, T; Lukka, H; Eisenhauer, E; Bacon, M; Tu, D; Parmar, M K B; Amos, C; Murray, C; Qian, W

    2009-01-10

    Early endometrial cancer with low-risk pathological features can be successfully treated by surgery alone. External beam radiotherapy added to surgery has been investigated in several small trials, which have mainly included women at intermediate risk of recurrence. In these trials, postoperative radiotherapy has been shown to reduce the risk of isolated local recurrence but there is no evidence that it improves recurrence-free or overall survival. We report the findings from the ASTEC and EN.5 trials, which investigated adjuvant external beam radiotherapy in women with early-stage disease and pathological features suggestive of intermediate or high risk of recurrence and death from endometrial cancer. Between July, 1996, and March, 2005, 905 (789 ASTEC, 116 EN.5) women with intermediate-risk or high-risk early-stage disease from 112 centres in seven countries (UK, Canada, Poland, Norway, New Zealand, Australia, USA) were randomly assigned after surgery to observation (453) or to external beam radiotherapy (452). A target dose of 40-46 Gy in 20-25 daily fractions to the pelvis, treating five times a week, was specified. Primary outcome measure was overall survival, and all analyses were by intention to treat. These trials were registered ISRCTN 16571884 (ASTEC) and NCT 00002807 (EN.5). After a median follow-up of 58 months, 135 women (68 observation, 67 external beam radiotherapy) had died. There was no evidence that overall survival with external beam radiotherapy was better than observation, hazard ratio 1.05 (95% CI 0.75-1.48; p=0.77). 5-year overall survival was 84% in both groups. Combining data from ASTEC and EN.5 in a meta-analysis of trials confirmed that there was no benefit in terms of overall survival (hazard ratio 1.04; 95% CI 0.84-1.29) and can reliably exclude an absolute benefit of external beam radiotherapy at 5 years of more than 3%. With brachytherapy used in 53% of women in ASTEC/EN.5, the local recurrence rate in the observation group at 5 years

  9. On the autarchic use of solely PIXE data in particulate matter source apportionment studies by receptor modeling

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Nava, S., E-mail: nava@fi.infn.it [National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Calzolai, G. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M. [National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Giannoni, M.; Traversi, R.; Udisti, R. [Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy)

    2015-11-15

    Particle Induced X-ray Emission (PIXE) analysis of aerosol samples allows simultaneous detection of several elements, including important tracers of many particulate matter sources. This capability, together with the possibility of analyzing a high number of samples in very short times, makes PIXE a very effective tool for source apportionment studies by receptor modeling. However, important aerosol components, like nitrates, OC and EC, cannot be assessed by PIXE: this limitation may strongly compromise the results of a source apportionment study if based on PIXE data alone. In this work, an experimental dataset characterised by an extended chemical speciation (elements, EC–OC, ions) is used to test the effect of reducing input species in the application of one of the most widely used receptor model, namely Positive Matrix Factorization (PMF). The main effect of using only PIXE data is that the secondary nitrate source is not identified and the contribution of biomass burning is overestimated, probably due to the similar seasonal pattern of these two sources.

  10. New Generation GridPix: Development and characterisation of pixelated gaseous detectors based on the Timepix3 chip

    CERN Document Server

    AUTHOR|(CDS)2082958; Hessey, Nigel

    Due to the increasing demands of high energy physics experiments there is a need for particle detectors which enable high precision measurements. In this regard, the GridPix detector is a novel detector concept which combines the benefits of a pixel chip with an integrated gas amplification structure. The resulting unit is a detector sensitive to single electrons with a great potential for particle tracking and energy loss measurements. This thesis is focusing on the development of a new generation of GridPix detectors based on the Timepix3 chip, which implements a high resolution Time to Digital Converter (TDC) in each pixel. After an introductory chapter describing the motivation behind GridPix, the manuscript presents the physics of gaseous detectors in chapter 2 along with the gaseous detectors used for particle tracking in chapter 3. Chapters 4 and 5 are focusing on the tracking performance of GridPix detectors. Chapter 4 presents results obtained with a GridPix detector based on a small scale prototy...

  11. On Interactions of Oscillation Modes for a Weakly Non-Linear Undamped Elastic Beam with AN External Force

    Science.gov (United States)

    BOERTJENS, G. J.; VAN HORSSEN, W. T.

    2000-08-01

    In this paper an initial-boundary value problem for the vertical displacement of a weakly non-linear elastic beam with an harmonic excitation in the horizontal direction at the ends of the beam is studied. The initial-boundary value problem can be regarded as a simple model describing oscillations of flexible structures like suspension bridges or iced overhead transmission lines. Using a two-time-scales perturbation method an approximation of the solution of the initial-boundary value problem is constructed. Interactions between different oscillation modes of the beam are studied. It is shown that for certain external excitations, depending on the phase of an oscillation mode, the amplitude of specific oscillation modes changes.

  12. Optimisation of Pt sensitivity in PIXE analysis of thin biological samples

    International Nuclear Information System (INIS)

    Tiourina, T.B.; Mutsaers, P.H.A.; Voigt, M.J.A. de

    1998-01-01

    To obtain Pt concentration distributions in tumor biopsies, micro-PIXE is used. The limit of detection (LOD) for Pt is determined by the background production cross section together with the production cross section for the Pt-L lines. Both are functions of the type and energy of the projectile. In order to optimise the experimental conditions, the proton energy is varied from 2.5 to 5 MeV and the corresponding X-ray spectra are analysed. The optimum LOD is about 1 μg/g for a sample thickness of 1 mg/cm 2 and a total charge of 100 μC. A study is performed to investigate the possibility of elemental analysis by means of α excitation. The corresponding LOD is 6 μg/g with 200 μC charge (He ++ was used). For α excitation, sample damage limits the beam current and, thus, causes a tremendous increase in the measurement time. (orig.)

  13. Analysis of powdered milk by PIXE (Proton Induced X-ray Emission)

    International Nuclear Information System (INIS)

    Desales Galeana, G.

    1990-01-01

    The purpose of this work was to establish the conditions to analyze elements of Z>15 in powdered milk samples using the PIXE technique. Ten different commercial samples were analyzed: 2 full-cream, 3 half-cream and 5 for infant feeding. They were all purchased in Toluca City, Mexico. Thick targets were prepared and irradiated with 1.5 and 3 MeV protons beam in Mexico's Nuclear Center Tandem Van de Graff Accelerator. The obtained data were analyzed by two computers programs. Iron, the reference element was analyzed by atomic absorption spectrometry. Concentrations of the following elements: phosphorus, chlorine, potassium, calcium, chrome, iron, cobalt, nickel, copper, zinc, bromine, rubidium, molybdenum and cadmium were evaluated. The concentrations of the first four elements were usually high, whereas those of the other elements remained in some ppm. The experimental conditions set up in this work were suitable for the analysis of powdered milk and can be applied to other organic samples (Author)

  14. A practical method to calculate head scatter factors in wedged rectangular and irregular MLC shaped beams for external and internal wedges

    International Nuclear Information System (INIS)

    Georg, Dietmar; Olofsson, Joergen; Kuenzler, Thomas; Aiginger, Hannes; Karlsson, Mikael

    2004-01-01

    Factor based methods for absorbed dose or monitor unit calculations are often based on separate data sets for open and wedged beams. The determination of basic beam parameters can be rather time consuming, unless equivalent square methods are applied. When considering irregular wedged beams shaped with a multileaf collimator, parametrization methods for dosimetric quantities, e.g. output ratios or wedge factors as a function of field size and shape, become even more important. A practical method is presented to derive wedged output ratios in air (S c,w ) for any rectangular field and for any irregular MLC shaped beam. This method was based on open field output ratios in air (S c ) for a field with the same collimator setting, and a relation f w between S c,w and S c . The relation f w can be determined from measured output ratios in air for a few open and wedged fields including the maximum wedged field size. The function f w and its parametrization were dependent on wedge angle and treatment head design, i.e. they were different for internal and external wedges. The proposed method was tested for rectangular wedged fields on three accelerators with internal wedges (GE, Elekta, BBC) and two accelerators with external wedges (Varian). For symmetric regular beams the average deviation between calculated and measured S c,w /S c ratios was 0.3% for external wedges and about 0.6% for internal wedges. Maximum deviations of 1.8% were obtained for elongated rectangular fields on the GE and ELEKTA linacs with an internal wedge. The same accuracy was achieved for irregular MLC shaped wedged beams on the accelerators with MLC and internal wedges (GE and Elekta), with an average deviation <1% for the fields tested. The proposed method to determine output ratios in air for wedged beams from output ratios of open beams, combined with equivalent square approaches, can be easily integrated in empirical or semi-empirical methods for monitor unit calculations

  15. Optimum location of external markers using feature selection algorithms for real-time tumor tracking in external-beam radiotherapy: a virtual phantom study.

    Science.gov (United States)

    Nankali, Saber; Torshabi, Ahmad Esmaili; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-08

    In external-beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation-based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two "Genetic" and "Ranker" searching procedures. The performance of these algorithms has been evaluated using four-dimensional extended cardiac-torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro-fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F-test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation-based feature selection algorithm, in

  16. Treatment of Head and Neck Paragangliomas With External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    Dupin, Charles; Lang, Philippe; Dessard-Diana, Bernadette; Simon, Jean-Marc; Cuenca, Xavier; Mazeron, Jean-Jacques; Feuvret, Loïc

    2014-01-01

    Purpose: To retrospectively assess the outcomes of radiation therapy in patients with head and neck paragangliomas. Methods and Materials: From 1990 to 2009, 66 patients with 81 head and neck paragangliomas were treated by conventional external beam radiation therapy in 25 fractions at a median dose of 45 Gy (range, 41.4-68 Gy). One case was malignant. The median gross target volume and planning target volume were 30 cm 3 (range, 0.9-243 cm 3 ) and 116 cm 3 (range, 24-731 cm 3 ), respectively. Median age was 57.4 years (range, 15-84 years). Eleven patients had multicentric lesions, and 8 had family histories of paraganglioma. Paragangliomas were located in the temporal bone, the carotid body, and the glomus vagal in 51, 18, and 10 patients, respectively. Forty-six patients had exclusive radiation therapy, and 20 had salvage radiation therapy. The median follow-up was 4.1 years (range, 0.1-21.2 years). Results: One patient had a recurrence of temporal bone paraganglioma 8 years after treatment. The actuarial local control rates were 100% at 5 years and 98.7% at 10 years. Patients with multifocal tumors and family histories were significantly younger (42 years vs 58 years [P=.002] and 37 years vs 58 years [P=.0003], respectively). The association between family predisposition and multifocality was significant (P<.001). Two patients had cause-specific death within the 6 months after irradiation. During radiation therapy, 9 patients required hospitalization for weight loss, nausea, mucositis, or ophthalmic zoster. Two late vascular complications occurred (middle cerebral artery and carotid stenosis), and 2 late radiation-related meningiomas appeared 15 and 18 years after treatment. Conclusion: Conventional external beam radiation therapy is an effective and safe treatment option that achieves excellent local control; it should be considered as a first-line treatment of choice for head and neck paragangliomas

  17. Quasi-plane-hypothesis of strain coordination for RC beams seismically strengthened with externally-bonded or near-surface mounted fiber reinforced plastic

    Science.gov (United States)

    Ren, Zhenhua; Zeng, Xiantao; Liu, Hanlong; Zhou, Fengjun

    2013-03-01

    The application of fiber reinforced plastic (FRP), including carbon FRP and glass FRP, for structural repair and strengthening has grown due to their numerous advantages over conventional materials such as externally bonded reinforcement (EBR) and near-surface mounted (NSM) strengthening techniques. This paper summarizes the results from 21 reinforced concrete beams strengthened with different methods, including externally-bonded and near-surface mounted FRP, to study the strain coordination of the FRP and steel rebar of the RC beam. Since there is relative slipping between the RC beam and the FRP, the strain of the FRP and steel rebar of the RC beam satisfy the quasi-plane-hypothesis; that is, the strain of the longitudinal fiber that parallels the neutral axis of the plated beam within the scope of the effective height ( h 0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of the FRP and steel rebar satisfies the equation: ɛ FRP= βɛ steel, and the value of β is equal to 1.1-1.3 according to the test results.

  18. A βPIX-PAK2 complex confers protection against Scrib-dependent and cadherin-mediated apoptosis

    DEFF Research Database (Denmark)

    Frank, Scott R; Bell, Jennifer H; Frödin, Morten

    2012-01-01

    During epithelial morphogenesis, a complex comprising the βPIX (PAK-interacting exchange factor β) and class I PAKs (p21-activated kinases) is recruited to adherens junctions. Scrib, the mammalian ortholog of the Drosophila polarity determinant and tumor suppressor Scribble, binds βPIX directly. ...

  19. External Beam Radiotherapy for Prostate Cancer Patients on Anticoagulation Therapy: How Significant is the Bleeding Toxicity?

    International Nuclear Information System (INIS)

    Choe, Kevin S.; Jani, Ashesh B.; Liauw, Stanley L.

    2010-01-01

    Purpose: To characterize the bleeding toxicity associated with external beam radiotherapy for prostate cancer patients receiving anticoagulation (AC) therapy. Methods and Materials: The study cohort consisted of 568 patients with adenocarcinoma of the prostate who were treated with definitive external beam radiotherapy. Of these men, 79 were receiving AC therapy with either warfarin or clopidogrel. All patients were treated with three-dimensional conformal radiotherapy or intensity-modulated radiotherapy. Bleeding complications were recorded during treatment and subsequent follow-up visits. Results: With a median follow-up of 48 months, the 4-year actuarial risk of Grade 3 or worse bleeding toxicity was 15.5% for those receiving AC therapy compared with 3.6% among those not receiving AC (p < .0001). On multivariate analysis, AC therapy was the only significant factor associated with Grade 3 or worse bleeding (p < .0001). For patients taking AC therapy, the crude rate of bleeding was 39.2%. Multivariate analysis within the AC group demonstrated that a higher radiotherapy dose (p = .0408), intensity-modulated radiotherapy (p = 0.0136), and previous transurethral resection of the prostate (p = .0001) were associated with Grade 2 or worse bleeding toxicity. Androgen deprivation therapy was protective against bleeding, with borderline significance (p = 0.0599). Dose-volume histogram analysis revealed that Grade 3 or worse bleeding was minimized if the percentage of the rectum receiving ≥70 Gy was <10% or the rectum receiving ≥50 Gy was <50%. Conclusion: Patients taking AC therapy have a substantial risk of bleeding toxicity from external beam radiotherapy. In this setting, dose escalation or intensity-modulated radiotherapy should be used judiciously. With adherence to strict dose-volume histogram criteria and minimizing hotspots, the risk of severe bleeding might be reduced.

  20. PIXE analysis of tumors and localization behavior of a lanthanide in nude mice

    Science.gov (United States)

    Chang, Pei-Jiun; Yang, Czau-Siung; Chou, Ming-Ji; Wei, Chau-Chin; Hsu, Chu-Chung; Wang, Chia-Yu

    1984-04-01

    We have used particle induced X-ray emission (PIXE) to analyze the elemental compositions and uptakes of a lanthanide, yttrium in this report, in tumors and normal tissues of nude mice. A small amount of yttrium nitrate was injected into nude mice with tumors. Samples of normal and malignant tissues taken from these mice were bombarded by the 2 MeV proton beam from a 3 MeV Van de Graaff accelerator with a Ge detector system to determine the relative elemental compositions of tissues and the relative concentrations of yttrium taken up by these tissues. We found that the uptakes of yttrium by tumors were at least five times more than those by normal tissues. Substantial differences were often observed between the trace element weight (or concentration) pattern of the cancerous and normal tissues. The present result is compared with human tissues.

  1. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Xia, H.N.; Jiang, J.C.; Yang, F.J.

    2002-01-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed

  2. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    Science.gov (United States)

    Cheng, H. S.; Zhang, Z. Q.; Xia, H. N.; Jiang, J. C.; Yang, F. J.

    2002-05-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed.

  3. Mapping of heavy metals accumulated in plants using submilli-pixe camera

    International Nuclear Information System (INIS)

    Watanabe, R.; Hara, J.; Inoue, C.; Chida, T.; Amartaivan, TS.; Matsuyama, S.; Yamazaki, H.; Ishii, K.

    2004-01-01

    Phytoremediation is a technology for remediation of contaminated soils. In this study, we used a submilli-PIXE camera to analyze plants and soils from a shooting range. Some heavy metals were rapidly and easily detected in these samples. Element dot-maps of the plant show Cu and Pb accumulated in the epidermis of subterranean stems and the venation of leaves. From these findings, it is possible to map the distribution of heavy metals and to detail their location in the plant, using the submilli-PIXE analysis is an effective tool for undertaking phytoremediation research. (author)

  4. Qualitative analysis of a powdered diamond sample by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Mabida, C.; Annegarn, H.J.; Renan, M.J.; Sellschop, J.P.F.

    The main purpose of this analysis was to determine whether nickel is present in diamond powder as a trace element. Particle induced X-ray emission (PIXE) showed unambiguously that nickel was present. Due to the convenience of PIXE in multielemental analysis, the investigations also include a number of other trace elements in the sample

  5. PIXE analysis of tree leaves as a possible comparative integral monitor of particulates in urban areas

    International Nuclear Information System (INIS)

    Zucchiati, A.; Annegarm, H.J.; Chisci, R.

    1988-01-01

    The possibility of obtaing integral comparative data for particulate distribution in urban areas from PIXE analysis of tree leaves is discussed in relation to the leaf gross anatomy, to the diffusion of selected tree species in such areas and to the implementation of experimental techniques necessary to make PIXE analysis effective. Multielemental scans were performed on a small set samples; results are compared to PIXE analysis of typical urban aerosols. The validity of the method and the criteria for yearly relative comparisons of different areas are discissed

  6. Micro-PIXE study of whole otolith of Anguilla japonica at elver stage

    International Nuclear Information System (INIS)

    Zheng, Y.; Guo, H.; Wei, K.; Tang, W.; Satoh, T.; Ohkubo, T.; Yamazaki, A.; Takano, K.; Kamiya, T.; Shen, H.; Yang, M.; Mi, Y.

    2010-01-01

    Strontium and calcium contents, within the otolith of Anguilla japonica, were measured by external micro-PIXE. According to the measured metamorphic checks, each otolith was divided into three stages. Comparing with the Sr:Ca ratios in stage 2, the ratios in stage 1 had two different trends. Among these fish, it may reflect their maternal condition was not the same. The ratios in stage 3 which was corresponding to the estuarine habitat were smaller than that in any other stage which was corresponding to the ocean habitat in each otolith. Suggested by our results, the eels from the spawning site may separate into two groups when they are near to the south of Taiwan, and then move to the different estuaries in China. It could be proposed that, in general, the migration direction is from south to north along the east coast in China.

  7. Micro-PIXE study of whole otolith of Anguilla japonica at elver stage

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Guo, H.; Wei, K.; Tang, W. [Institute of Life Science, Shanghai Fisheries University, Shanghai 200090 (China); Satoh, T.; Ohkubo, T.; Yamazaki, A.; Takano, K.; Kamiya, T. [Takasaki Advanced Radiation Research Institute, JAEA, Gunma 370-1292 (Japan); Shen, H., E-mail: haoshen@fudan.edu.c [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Yang, M.; Mi, Y. [Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2010-06-15

    Strontium and calcium contents, within the otolith of Anguilla japonica, were measured by external micro-PIXE. According to the measured metamorphic checks, each otolith was divided into three stages. Comparing with the Sr:Ca ratios in stage 2, the ratios in stage 1 had two different trends. Among these fish, it may reflect their maternal condition was not the same. The ratios in stage 3 which was corresponding to the estuarine habitat were smaller than that in any other stage which was corresponding to the ocean habitat in each otolith. Suggested by our results, the eels from the spawning site may separate into two groups when they are near to the south of Taiwan, and then move to the different estuaries in China. It could be proposed that, in general, the migration direction is from south to north along the east coast in China.

  8. Applications of PIXE to studies in dental and mental healths

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Melbourne Univ., Austin; Ainsworth, T.

    1981-01-01

    The elemental composition of healthy and diseased teeth from 25 South Australian children have been determined using thick target PIXE analysis. Different dental hard tissues, namely enamel, dentine, cementum and the amelodentinal junction, were analysed independently. A number of elements, Na, Mg, Al, P, S, Cl, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb have been detected, and their concentrations measured. The concentrations of some of the elements were found to very considerable between: (a) healthy and diseases teeth, (b) teeth of the same type, and (c) different parts of the same tooth. Attemps have been made to correlate the concentrations of the various elements with the health of the teeth. In a pilot study, PIXE has also been applied for Pb analysis in the teeth of a few mentally retarded children. The teeth of all the children, with the exception of one who was suffering from Downe's syndrome, were found to contain appreciable amounts of lead. It is suggested that PIXE would provide a more convenient and accurate form of analysis than destructive chemical methods, for correlation Pb in children's teeth with their mental abilities. (orig.)

  9. Analysis of biological materials by RBS and PIXE methods

    International Nuclear Information System (INIS)

    Latuszynski, A.; Maczka, D.; Kobzev, A. P.

    2002-01-01

    A problem of the exact determination of the element concentration in different substances is of essential significance, especially in medical, biological, as well as environment protection investigations. For this purpose some chemical and physical methods are used such as very sensitive and precise techniques: PIXE and RBS. The main advantage of those methods is the sensitivity of ppm level and very small sample amount necessary for carrying out the investigations. In this article the investigation results obtained by PIXE and RBS methods for the metal contents in cow milk (18 various samples were studied) as well as the heavy metal admixtures in the brain of the living domestic animals (6 cows, 6 dogs and 17 rats) are presented. The samples were prepared for the analysis in a liofilization process, then they were mixed with spectral pure graphite. The PIXE and RBS investigations were performed using a proton beam of about 2 mm diameter, intensity of about 10 nA and energy of 2.5 MeV from the Van-de-Graaff generator, FLNP, JINR, Dubna. The measurements of the characteristic spectrum were carried out by means of a Si (Li) detector with the resolution of 200 eV at the energy of 6,4 keV. Generally, in all samples of milk and brain we could identify 20 elements, among them 13 (C, N, O, P, Cl, K, Ca, Fe, Cu, Zn. Br, Rb, Sr) appeared in all of the studied samples. The difference in the concentration of the most of those elements between samples was in the range of 15 - 20 %. This indicates a good accuracy of the used methods of measurement. Especially our attention was paid to the presence of Sr, Rb and Br, practically in all the milk samples. This fact requires further investigations. Such elements as Pb, As, Ni, Co, Mn, V and Ti were found in some samples, including all samples coming from regions of a high urbanization. It is characteristic that the milk samples coming from villages located considerably far-away from cities and from communication tracks, practically

  10. Spatially resolved element analysis of historical violin varnishes by use of muPIXE.

    Science.gov (United States)

    von Bohlen, Alex; Röhrs, Stefan; Salomon, Joseph

    2007-02-01

    External muPIXE has been used for characterisation of small samples of varnish from historical violins, and pieces of varnished wood from historical and modern stringed instruments. To obtain spatially resolved information about the distribution of elements across the varnish layers single-spot analysis, line-scans, and area-mapping were performed. Local resolution of approximately 20 mum was obtained from the 3 MeV, 1 nA proton micro-probe. Results from simultaneous multi-element determination of Na, Mg, Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Rb, Sr, Ag, Cd, Sn, Ba, and Pb in historical varnishes are presented. Semi-quantitative evaluation of line-scans recorded on diverse historical varnishes is reported. The applied method is discussed in detail and the results obtained are critically reviewed and compared with those in the literature.

  11. The set-up for forward scattered particle detection at the external microbeam facility of the INFN-LABEC laboratory in Florence

    International Nuclear Information System (INIS)

    Giuntini, L.; Massi, M.; Calusi, S.; Gelli, N.; Castelli, L.; Carraresi, L.; Czelusniak, C.; Fedi, M.E.; Gueli, A.M.; Liccioli, L.; Mandò, P.A.; Mazzinghi, A.; Palla, L.

    2015-01-01

    In the last few years some new implementations and upgrades have been made to the external scanning microbeam of INFN-LABEC laboratory in Florence, enriching the existing PIXE, PIGE, BS, IBIL set-up with complementary techniques, when possible allowing for simultaneous multi-technique analyses. We developed a system, compatible with the existing set-up, for the out-of-vacuum detection of the forward scattered particles. This system makes feasible the external-STIM (Scanning Transmission Ion Microscopy) and external-FS (Forward Scattering), now both available at our beamline. Test measurements are shortly presented

  12. Research of transportation efficiency of low-energy high- current electron beam in plasma channel in external magnetic field

    International Nuclear Information System (INIS)

    Vagin, E S; Grigoriev, V P

    2015-01-01

    Effective high current (5-20 kA) and low energy (tens of keV) electrons beam transportation is possible only with almost complete charging neutralization. It is also necessary to use quite high current neutralization for elimination beam self-pinching effect. The research is based on the self-consistent mathematical model that takes into account beam and plasma particles dynamic, current and charge neutralization of electron beam and examines the transportation of electron beam into a chamber with low-pressure plasma in magnetic field. A numerical study was conducted using particle in cell (PIC) method. The study was performed with various system parameters: rise time and magnitude of the beam current, gas pressure and plasma density and geometry of the system. Regularities of local virtual cathode field generated by the beam in the plasma channel, as well as ranges of parameters that let transportation beam with minimal losses, depending on the external magnetic field were determined through a series of numerical studies. In addition, the assessment of the impact of the plasma ion mobility during the transition period and during steady beam was performed. (paper)

  13. Radiation dose to laterally transposed ovaries during external beam radiotherapy for cervical cancer

    International Nuclear Information System (INIS)

    Mazonakis, Michael; Damilakis, John; Varveris, Haris; Gourtsoyiannis, Nicholas

    2006-01-01

    The purpose of this study was to estimate the radiation dose to laterally transposed ovaries from external beam radiotherapy for cervical cancer. Dose measurements were performed in a modified humanoid phantom using a 6 MV photon beam. The dependence of the ovarian dose upon the field size, the distance from the primary irradiation field and the presence of wedges or gonadal shielding was determined. For a tumor dose of 45 Gy, ovarian dose was 0.88-8.51 Gy depending on the field size employed and the location of the transposed ovary in respect to the treatment field. Positioning of 7 cm thick shielding reduced the dose to ovary by less than 19%. The use of wedges increased the ovarian dose by a factor up to 1.5. Accurate radiographic localization of the ovaries allows the use of the presented dosimetric results to obtain a reasonable prediction of the ovarian dose

  14. Total CMB analysis of streaker aerosol samples by PIXE, PIGE, beta- and optical-absorption analyses

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Przybylowicz, W.J.

    1993-01-01

    Multielemental analyses of aerosol samples are widely used in air pollution receptor modelling. Specifically, the chemical mass balance (CMB) model has become a powerful tool in urban air quality studies. Input data required for the CMB includes not only the traditional X-ray fluorescence (and hence PIXE) detected elements, but also total mass, organic and inorganic carbon, and other light elements including Mg, Na and F. The circular streaker sampler, in combination with PIXE analysis, has developed into a powerful tool for obtaining time-resolved, multielemental aerosol data. However, application in CMB modelling has been limited by the absence of total mass and complementary light element data. This study reports on progress in using techniques complementary to PIXE to obtain additional data from circular streaker samples, maintaining the nondestructive, instrumental approach inherent in PIXE: Beta-gauging using a 147 Pm source for total mass; optical absorption for inorganic carbon; and PIGE to measure the lighter elements. (orig.)

  15. Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sole, Claudio V., E-mail: cvsole@uc.cl [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); Calvo, Felipe A. [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Madrid (Spain); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain); Alvarez, Ana; Gonzalez, Carmen [Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Gonzalez, Jose [Service of Pediatric Orthopedics and Traumatology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); San Julian, Mikel [Service of Orthopedics and Traumatology, Clínica Universidad de Navarra, Pamplona (Spain); Martinez-Monge, Rafael [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain)

    2014-09-01

    Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results.

  16. Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

    International Nuclear Information System (INIS)

    Sole, Claudio V.; Calvo, Felipe A.; Polo, Alfredo; Cambeiro, Mauricio; Alvarez, Ana; Gonzalez, Carmen; Gonzalez, Jose; San Julian, Mikel; Martinez-Monge, Rafael

    2014-01-01

    Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results

  17. Surface topography of 1€ coin measured by stereo-PIXE

    International Nuclear Information System (INIS)

    Gholami-Hatam, E.; Lamehi-Rachti, M.; Vavpetič, P.; Grlj, N.; Pelicon, P.

    2013-01-01

    We demonstrate the stereo-PIXE method by measurement of surface topography of the relief details on 1€ coin. Two X-ray elemental maps were simultaneously recorded by two X-ray detectors positioned at the left and the right side of the proton microbeam. The asymmetry of the yields in the pixels of the two X-ray maps occurs due to different photon attenuation on the exit travel path of the characteristic X-rays from the point of emission through the sample into the X-ray detectors. In order to calibrate the inclination angle with respect to the X-ray asymmetry, a flat inclined surface model was at first applied for the sample in which the matrix composition and the depth elemental concentration profile is known. After that, the yield asymmetry in each image pixel was transferred into corresponding local inclination angle using calculated dependence of the asymmetry on the surface inclination. Finally, the quantitative topography profile was revealed by integrating the local inclination angle over the lateral displacement of the probing beam

  18. LePIX: First results from a novel monolithic pixel sensor

    International Nuclear Information System (INIS)

    Mattiazzo, S.; Battaglia, M.; Bisello, D.; Caselle, M.; Chalmet, P.; Demaria, N.; Giubilato, P.; Ikemoto, Y.; Kloukinas, K.; Mansuy, C.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rivetti, A.; Rousset, J.; Silvestrin, L.; Snoeys, W.; Wyss, J.

    2013-01-01

    We present a monolithic pixel sensor developed in the framework of the LePIX project aimed at tracking/triggering tasks where high granularity, low power consumption, material budget, radiation hardness and production costs are a concern. The detector is built in a 90 nm CMOS process on a substrate of moderate resistivity. This maintains the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, but offers charge collection by drift from a depleted region and therefore an excellent signal to noise ratio and a radiation tolerance superior to conventional undepleted MAPS. Measurement results obtained with the first prototypes from laser, radioactive source and beam test experiments are described. The excellent signal-to-noise performance is demonstrated by the capability of the device to separate the peaks in the spectrum of a 55 Fe source. We will also highlight the interaction between pixel cell design and architecture which points toward a very precise direction in the development of such depleted monolithic pixel devices for high energy physics

  19. Interstitial gold and external beam irradiation for prostate cancer

    International Nuclear Information System (INIS)

    Boileau, M.A.; Dowling, R.A.; Gonzales, M.; Handel, P.H.; Benson, G.S.; Corriere, J.N. Jr.

    1988-01-01

    We treated 65 patients with prostatic cancer confined clinically to the prostate or periprostatic area during an 8-year period. Seven patients had stage A2, 38 stage B and 20 stage C disease. All 65 patients underwent staging pelvic lymphadenectomy and implantation of gold grains into the prostate (mean dose 3,167 rad). A total of 64 patients then completed a course of external beam irradiation to a mean total tumor dose of 6,965 rad. Complications of therapy were mild and limited (less than 3 months in duration) in most patients, and they included radiation cystitis (32 per cent), diarrhea (31 per cent), extremity lymphedema (7.7 per cent) and wound infection (3 per cent). Two patients suffered urinary incontinence after therapy and 2 (3 per cent) had diarrhea more than 3 months in duration. The actuarial 5-year survival rate for all patients was 87 per cent and the 5-year survival free of disease was 72 per cent

  20. Dosimetric comparison between intensity modulated brachytherapy versus external beam intensity modulated radiotherapy for cervix cancer: a treatment planning study

    International Nuclear Information System (INIS)

    Subramani, V.; Sharma, D.N.; Jothy Basu, K.S.; Rath, G.K.; Gopishankar, N.

    2008-01-01

    To evaluate the dosimetric superiority of intensity modulated brachytherapy (IMBT) based on inverse planning optimization technique with classical brachytherapy optimization and also with external beam intensity modulated radiotherapy planning technique in patients of cervical carcinoma

  1. Internal hemipelvectomy with intraoperative and external beam radiotherapy in the limb-sparing treatment of a pelvic girdle chondrosarcoma

    NARCIS (Netherlands)

    Hoekstra, HJ; Szabo, BG

    The case of a patient with an extensive pelvic girdle chondrosarcoma treated with internal hemipelvectomy and intraoperative radiotherapy, followed by adjuvant high-dose external beam radiotherapy, with a successful attempt in achieving long-term local tumor control and limb-sparing treatment is

  2. Phase-space database for external beam radiotherapy. Summary report of a consultants' meeting

    International Nuclear Information System (INIS)

    Capote, R.; Jeraj, R.; Ma, C.M.; Rogers, D.W.O.; Sanchez-Doblado, F.; Sempau, J.; Seuntjens, J.; Siebers, J.V.

    2006-01-01

    A summary is given of a Consultants' Meeting assembled to discuss and recommend actions and activities to prepare a Phase-space Database for External Beam Radiotherapy. The new database should serve to disseminate phase-space data of those accelerators and 60 Co units used in radiotherapy through the compilation of existing data that have been properly validated. Both the technical discussions and the resulting work plan are described, along with the detailed recommendations for implementation. The meeting was jointly organized by NAPC-Nuclear Data Section and NAHU-Dosimetry and Medical Radiation Physics Section. (author)

  3. IBA techniques: Examples of useful combinations for the characterisation of cultural heritage materials

    Science.gov (United States)

    Beck, L.; Pichon, L.; Moignard, B.; Guillou, T.; Walter, P.

    2011-12-01

    For many years, ion beam analysis techniques have successfully been used to the study of cultural heritage objects. The chemical composition of work art is usually determined by PIXE, but in many cases, RBS and/or PIGE can provide useful complementary information. RBS gives information about the depth distribution and concentration in light elements, such as carbon and oxygen. In the past years, the experimental facilities at the AGLAE (Accélérateur Grand Louvre d'Analyse Élémentaire) accelerator has been progressively developed in order to apply simultaneously PIXE, PIGE and RBS under optimal conditions using an external beam. This combination is now routinely used for point analyses or mappings. In this contribution, we present several examples of applications: manufacturing technology of lustre-decorated ceramics and silver plating, control of altered or restored surfaces, and quantification of organic phase in painting and bone. The final conclusion is that the association of PIXE with RBS is very attractive for the investigation of cultural heritage objects, in particular of materials containing both mineral and organic components or possessing a multilayered structure. The first results of the production of monochromatic X-rays for radiography purposes by PIXE are also presented.

  4. IBA techniques: Examples of useful combinations for the characterisation of cultural heritage materials

    International Nuclear Information System (INIS)

    Beck, L.; Pichon, L.; Moignard, B.; Guillou, T.; Walter, P.

    2011-01-01

    For many years, ion beam analysis techniques have successfully been used to the study of cultural heritage objects. The chemical composition of work art is usually determined by PIXE, but in many cases, RBS and/or PIGE can provide useful complementary information. RBS gives information about the depth distribution and concentration in light elements, such as carbon and oxygen. In the past years, the experimental facilities at the AGLAE (Accélérateur Grand Louvre d’Analyse Élémentaire) accelerator has been progressively developed in order to apply simultaneously PIXE, PIGE and RBS under optimal conditions using an external beam. This combination is now routinely used for point analyses or mappings. In this contribution, we present several examples of applications: manufacturing technology of lustre-decorated ceramics and silver plating, control of altered or restored surfaces, and quantification of organic phase in painting and bone. The final conclusion is that the association of PIXE with RBS is very attractive for the investigation of cultural heritage objects, in particular of materials containing both mineral and organic components or possessing a multilayered structure. The first results of the production of monochromatic X-rays for radiography purposes by PIXE are also presented.

  5. Development of a scanning proton microprobe - computer-control, elemental mapping and applications

    International Nuclear Information System (INIS)

    Loevestam, Goeran.

    1989-08-01

    A scanning proton microprobe set-up has been developed at the Pelletron accelerator in Lund. A magnetic beam scanning system and a computer-control system for beam scanning and data aquisition is described. The computer system consists of a VMEbus front-end computer and a μVax-II host-computer, interfaced by means of a high-speed data link. The VMEbus computer controls data acquisition, beam charge monitoring and beam scanning while the more sophisticated work of elemental mapping and spectrum evaluations is left to the μVax-II. The calibration of the set-up is described as well as several applications. Elemental micro patterns in tree rings and bark has been investigated by means of elemental mapping and quantitative analysis. Large variations of elemental concentrations have been found for several elements within a single tree ring. An external beam set-up has been developed in addition to the proton microprobe set-up. The external beam has been used for the analysis of antique papyrus documents. Using a scanning sample procedure and particle induced X-ray emission (PIXE) analysis, damaged and missing characters of the text could be made visible by means of multivariate statistical data evaluation and elemental mapping. Also aspects of elemental mapping by means of scanning μPIXE analysis are discussed. Spectrum background, target thickness variations and pile-up are shown to influence the structure of elemental maps considerably. In addition, a semi-quantification procedure has been developed. (author)

  6. On finding the analytic dependencies of the external field potential on the control function when optimizing the beam dynamics

    Science.gov (United States)

    Ovsyannikov, A. D.; Kozynchenko, S. A.; Kozynchenko, V. A.

    2017-12-01

    When developing a particle accelerator for generating the high-precision beams, the injection system design is of importance, because it largely determines the output characteristics of the beam. At the present paper we consider the injection systems consisting of electrodes with given potentials. The design of such systems requires carrying out simulation of beam dynamics in the electrostatic fields. For external field simulation we use the new approach, proposed by A.D. Ovsyannikov, which is based on analytical approximations, or finite difference method, taking into account the real geometry of the injection system. The software designed for solving the problems of beam dynamics simulation and optimization in the injection system for non-relativistic beams has been developed. Both beam dynamics and electric field simulations in the injection system which use analytical approach and finite difference method have been made and the results presented in this paper.

  7. Minimal requirements for quality controls in radiotherapy with external beams; Controlli di qualita' essenziali in radioterapia con fasci esterni

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy. [Italian] Il gruppo di studio Assicurazione di qualita' in radioterapia dell'Istituto Superiore di Sanita' presenta le linee guida per la stesura dei protocolli di controllo di qualita' essenziali necessari a garantire un adeguato livello di accuratezza del trattamento radiante e rappresenta pertanto una parte essenziale del contributo fisico-dosimetrico globale di assicurazione di qualita' in radioterapia con fasci esterni.

  8. Air pollution studies using PIXE and ICP methods

    International Nuclear Information System (INIS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I V; Virgolici, M; Cimpoca, V; Gugiu, M; Vlaicu, Gh

    2006-01-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma (ICP) - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  9. Serum testosterone levels after external beam radiation for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Zagars, Gunar K.; Pollack, Alan

    1997-01-01

    Purpose: To determine whether serum total testosterone levels change after external beam radiation therapy for localized prostate cancer. Methods and Materials: Eighty-five men with clinically localized prostate cancer (T1-T3, N0/NX, M0) who underwent external beam radiation therapy without androgen ablation had pretreatment and 3-month posttreatment total serum testosterone levels determined by radioimmunoassay. Scattered doses to the testicles were measured with thermoluminescent dosimetry in 10 men. Results: Pretreatment serum testosterone levels ranged from 185 to 783 ng/dl, with a mean of 400 ng/dl and a median of 390 ng/dl. The coefficient of variation was 30%. Postradiation 3-month testosterone levels ranged from 163 ng/dl to 796 ng/dl, with mean and median values of 356 ng/dl and 327 ng/ml, respectively. The coefficient of variation was 34%. The 3-month value was significantly lower than the pretreatment value (Wilcoxon paired p = 0.0001). The mean absolute fall was 94 ng/dl and the mean percentage fall was 9%. Although the fall in testosterone level was statistically significant, the difference was very small quantitatively. In contrast, serum prostate-specific antigen levels fell dramatically by 3 months after radiation. Testicular scattered doses ranged from 1.84 to 2.42 Gy, with a mean of 2.07 Gy for a prostatic tumor dose of 68 Gy. Conclusions: Although significant, the fall in serum testosterone level after radiation for localized prostate cancer was small and likely of no pathophysiologic consequence. It is unlikely that scattered testicular radiation plays any significant role in the genesis of this change in testosterone level, which most likely occurs as a nonspecific stress response

  10. Calibration of a PIXE system for analysis of environmental aerosols; Calibracion de un sistema PIXE para analisis de aerosoles ambientales

    Energy Technology Data Exchange (ETDEWEB)

    Aldape, F; Diaz, R V; Anguiano, G; Flores M, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-04-15

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 {+-} 49 ng m{sup -3} is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  11. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S

    2015-01-01

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  12. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  13. Below-surface analysis of inclusions with PIXE and PIGE

    International Nuclear Information System (INIS)

    MacArthur, J.D.; Ma, X.P.; Palmer, G.R.; Anderson, A.J.; Clark, A.H.

    1990-01-01

    The composition of fluid inclusions in host minerals holds much information about the chemical environment of mineral formation. When solid inclusions are exposed through polishing, their content can readily be investigated with an electron or proton probe. However, with an electron probe, only the daughter minerals or the residue material left when a fluid inclusion is opened can be analyzed since electrons with energies of tens of keV cannot penetrate to the unexposed inclusion. On the other hand, proton beams of a few MeV can penetrate a few tens of μm of material and still be able to excite characteristic radiation. This phenomenon has been exploited for the analysis of subsurface inclusions. Ideally, standard petrographic sections are polished to that inclusions, targetted for analysis, are brought to within 10 μm of the surface. The overlying matrix reduces the sensitivity of PIXE for the elements of low Z such as Na and Al because of the attenuation of the X-rays. However, these elements, as well as elements of even lower Z, which cannot be analyzed with the electron probe, can readily be detected with PIGE at good sensitivity. (orig.)

  14. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  15. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  16. Preparation Of Thermoluminescence Dosimeters For External Radiotherapy Beam Audit In Malaysia

    International Nuclear Information System (INIS)

    Norhayati Abdullah; Siti Sara Deraman; Taiman Kadni; Mohd Taufik Dollah; Norhayati Salleh

    2014-01-01

    The external beam audit is a part of the Quality Assurance Programme (QAP) in radiotherapy that should be carried out to check the accuracy of dose delivered by the radiotherapy treatment units are within the tolerance limit of A ± 5 % as recommended by the International Commission of Radiation Units and Measurements (ICRU) Report No. 24. In this work, thermoluminescence dosimeters (TLD) in powder form were chosen to be used in the dose quality audit for the radiotherapy treatment units in Malaysia. As a preparation, the characterizations of a new batch of TLD-100 powders were studied. The studies include checks for the response of TLD-100 before and after pre-annealing process, reproducibility and linearity of TL signal. Results show that the response of TLD-100 powder after pre-annealing increases by 65 % compared with before pre-annealing process. These TLD-100 powders also provide reliable and consistent readings for the absorbed dose to water within the range of 150 cGy to 250 cGy with the maximum standard uncertainty of 0.554 μC. Finally, the calibration curves for 6 MV and 10 MV photon beams were established. These curves will be used in determining the absorbed dose to water (Dw) from user's irradiated TLDs. The expanded uncertainty (coverage factor k=2) of Dw determination was estimated to be 4.1 %. As a conclusion, these TLD-100 powders are ready to be used as a transfer detector for evaluating the accuracy of user's delivery dose in the radiotherapy beam audit program in Malaysia. (author)

  17. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    International Nuclear Information System (INIS)

    Correa, R.; Chesta, M.A.; Morales, J.R.; Dinator, M.I.; Requena, I.; Vila, I.

    2006-01-01

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses

  18. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Correa, R. [Universidad Tecnologica Metropolitana, Departamento de Fisica, Av. Jose Pedro Alessandri 1242, Nunoa, Santiago (Chile)]. E-mail: rcorrea@utem.cl; Chesta, M.A. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Medina Allende s/n Ciudad Universitaria, 5000 Cordoba (Argentina)]. E-mail: chesta@famaf.unc.edu.ar; Morales, J.R. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: rmorales@uchile.cl; Dinator, M.I. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: mdinator@uchile.cl; Requena, I. [Universidad de Granada, Departamento de Ciencias de la Computacion e Inteligencia Artificial, Daniel Saucedo Aranda s/n, 18071 Granada (Spain)]. E-mail: requena@decsai.ugr.es; Vila, I. [Universidad de Chile, Facultad de Ciencias, Departamento de Ecologia, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: limnolog@uchile.cl

    2006-08-15

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses.

  19. Biochemical failure after radical external beam radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Nomoto, Satoshi; Imada, Hajime; Kato, Fumio; Yahara, Katsuya; Morioka, Tomoaki; Ohguri, Takayuki; Nakano, Keita; Korogi, Yukunori

    2005-01-01

    The purpose of this study was to evaluate biochemical failures after radical external beam radiotherapy for prostate cancer. A total of 143 patients with prostate cancer (5 cases in stage A2, 95 in stage B and 43 in stage C; 18 in low risk group, 37 in intermediate risk group, 67 in high risk group and 21 in unknown group) were included in this study. Patients of stage A2 and B underwent external irradiation of 46 Gy to the prostate gland and seminal vesicle and additional 20 Gy to the prostate gland, while patients of stage C underwent external irradiation of 66 Gy to the prostate gland and seminal vesicle including 46 Gy to the pelvis. Neoadjuvant hormonal therapy was done in 66 cases, and long-term hormonal therapy in 75 cases; two cases were treated with radiation therapy alone. The 3-year relapse free survival rates by stage A2, B and C were 100%, 96.7% and 88.1%, respectively. The 3-year relapse free survival rates by low, intermediate and high risk groups were 100%, 92.3% and 89.7%, respectively. Biochemical failure was noted in nine cases during the average observation term of 32.2 months; in this group the median of prostate specific antigen (PSA) value was 2.6 ng/ml, the doubling time was 8.6 months, and the term of biochemical failure was 33.2 months. Six of eight cases with biochemical failure were the neoadjuvant hormonal therapy group, but biochemical no evidence of disease (bNED) curve showed no significant difference between neoadjuvant and long-term hormonal groups. It is supposed that unnecessary hormonal therapies were performed based on the nonspecific diagnosis of biochemical failure after radical radiotherapy in our group of patients. A precise criterion of biochemical failure after radical radiotherapy for prostate cancer is necessary. (author)

  20. PIXE as a characterization technique in the cutting tool industry

    International Nuclear Information System (INIS)

    Freemantle, C.S.; Sacks, N.; Topic, M.; Pineda-Vargas, C.A.

    2014-01-01

    Two WC–Co powders have been analyzed using micro-PIXE to identify elemental concentration and distribution. A powder recycled primarily from used mining components and a powder produced exclusively from fresh raw materials was studied. Elemental mapping of major elements as well as impurities, within powder granule cross sections, was performed. Contaminants (e.g. Fe and Ni) from manufacturing processes, as well as trace impurities (e.g. Cr, Cl, Ca and S) from recycling were detected, quantified and compared. The extent of increased concentrations of impurities resulting from recycling were observed, demonstrating the potential for PIXE as a characterization tool for detecting trace elements in cemented carbides, allowing for future improvements in the manufacturing and recycling processes