WorldWideScience

Sample records for external beam chemoradiation

  1. Cervix Regression and Motion During the Course of External Beam Chemoradiation for Cervical Cancer

    International Nuclear Information System (INIS)

    Beadle, Beth M.; Jhingran, Anuja; Salehpour, Mohammad; Sam, Marianne; Iyer, Revathy B.; Eifel, Patricia J.

    2009-01-01

    Purpose: To evaluate the magnitude of cervix regression and motion during external beam chemoradiation for cervical cancer. Methods and Materials: Sixteen patients with cervical cancer underwent computed tomography scanning before, weekly during, and after conventional chemoradiation. Cervix volumes were calculated to determine the extent of cervix regression. Changes in the center of mass and perimeter of the cervix between scans were used to determine the magnitude of cervix motion. Maximum cervix position changes were calculated for each patient, and mean maximum changes were calculated for the group. Results: Mean cervical volumes before and after 45 Gy of external beam irradiation were 97.0 and 31.9 cc, respectively; mean volume reduction was 62.3%. Mean maximum changes in the center of mass of the cervix were 2.1, 1.6, and 0.82 cm in the superior-inferior, anterior-posterior, and right-left lateral dimensions, respectively. Mean maximum changes in the perimeter of the cervix were 2.3 and 1.3 cm in the superior and inferior, 1.7 and 1.8 cm in the anterior and posterior, and 0.76 and 0.94 cm in the right and left lateral directions, respectively. Conclusions: Cervix regression and internal organ motion contribute to marked interfraction variations in the intrapelvic position of the cervical target in patients receiving chemoradiation for cervical cancer. Failure to take these variations into account during the application of highly conformal external beam radiation techniques poses a theoretical risk of underdosing the target or overdosing adjacent critical structures

  2. Chemoradiation in cervical cancer with cisplatin and high-dose rate brachytherapy combined with external beam radiotherapy. Results of a phase-II study

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, H.G.; Laban, C.; Puschmann, D.; Koelbl, H. [Dept. of Gynecology, Martin-Luther Univ. Halle-Wittenberg (Germany); Kuhnt, T.; Pigorsch, S.; Dunst, J.; Haensgen, G. [Dept. of Radiotherapy, Martin-Luther Univ. Halle-Wittenberg (Germany)

    2002-07-01

    Background: In 1999, five randomized studies demonstrated that chemoradiation with cisplatin and low-dose rate (LDR) brachytherapy has a benefit in locally advanced cervical cancer and for surgically treated patients in high-risk situations. We evaluated the safety and efficacy of concomitant chemoradiation with cisplatin and high-dose rate (HDR) brachytherapy in patients with cervical cancer. Patients and Method: 27 patients were included in our phase-II trial: 13 locally advanced cases (group A) and 14 adjuvant-therapy patients in high-risk situations (group B). A definitive radiotherapy was performed with 25 fractions of external beam therapy (1.8 Gy per fraction/middle shielded after eleven fractions). Brachytherapy was delivered at HDR schedules with 7 Gy in point A per fraction (total dose 35 Gy) in FIGO Stages IIB-IIIB. The total dose of external and brachytherapy was 70 Gy in point A and 52-54 Gy in point B. All patients in stage IVA were treated without brachytherapy. Adjuvant radiotherapy was performed with external beam radiotherapy of the pelvis with 1.8 Gy single-dose up to 50.4 Gy. Brachytherapy was delivered at HDR schedules with two fractions of 5 Gy only in patients with tumor-positive margins or tumor involvement of the upper vagina. The chemotherapeutic treatment schedule provided six courses of cisplatin 40 mg/m{sup 2} weekly recommended in the randomized studies GOG-120 and -123. Results: A total of 18/27 patients (66.7%) completed all six courses of chemotherapy. Discontinuation of radiotherapy due to therapy-related morbidity was not necessary in the whole study group. G3 leukopenia (29.6%) was the only relevant acute toxicity. There were no differences in toxicity between group A and B. Serious late morbidity occurred in 2/27 patients (7.4%). 12/13 patients (92.3%) with IIB-IVA cervical cancer showed a complete response (CR). 13/14 adjuvant cases (92.8%) are free of recurrence (median follow up: 19.1 months). Conclusion: Concomitant

  3. External proton and Li beams

    International Nuclear Information System (INIS)

    Schuff, Juan A.; Burlon, Alejandro A.; Debray, Mario E.; Kesque, Jose M.; Kreiner, Andres J.; Stoliar, Pablo A.; Naab, Fabian; Ozafran, Mabel J.; Vazquez, Monica E.; Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S.; Ruffolo, M.; Tasat, D.R.; Muhlmann, M. C.

    2000-01-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 μm gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 ± 0.07 MeV, 2.9 ± 0.10 MeV y 1.5 ± 0.1 MeV for protons and 21.4 ± 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with γ-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/μm. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  4. Partial breast radiation therapy - external beam

    Science.gov (United States)

    Carcinoma of the breast - partial radiation therapy; Partial external beam radiation - breast; Intensity-modulated radiation therapy - breast cancer; IMRT - breast cancer WBRT; Adjuvant partial breast - IMRT; APBI - IMRT; ...

  5. Chemo-radiation in advanced nasopharyngeal carcinoma, disease ...

    African Journals Online (AJOL)

    This is a case report of a patient with advanced nasopharyngeal Carcinoma, (T4 N2 MO) who had chemo-radiation with Cisplatin based chemotherapy and total midplane dose of 60 Gray external beam radiation. Six years after treatment patient has remained disease free and the primary site histologically confirmed ...

  6. Treatment optimisation using external beam radiation in ...

    African Journals Online (AJOL)

    The majority of patients with gynaecological cancers present with advanced stages in which external beam radiation forms a major component of the treatment. These patients undergo simulation for treatment planning prior to radiation. Currently the lower extent of the disease is evaluated by vaginal examination and ...

  7. Proton external beam in the TANDAR Accelerator

    International Nuclear Information System (INIS)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M.

    1998-01-01

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm 2 approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  8. Guide for External Beam Radiotherapy. Procedures 2007

    International Nuclear Information System (INIS)

    Ardiet, Jean-Michel; Bourhis, Jean; Eschwege, Francois; Gerard, Jean-Pierre; Martin, Philippe; Mazeron, Jean-Jacques; Barillot, Isabelle; Bey, Pierre; Cosset, Jean-Marc; Thomas, Olivier; Bolla, Michel; Bourguignon, Michel; Godet, Jean-Luc; Krembel, David; Valero, Marc; Bara, Christine; Beauvais-March, Helene; Derreumaux, Sylvie; Vidal, Jean-Pierre; Drouard, Jean; Sarrazin, Thierry; Lindecker-Cournil, Valerie; Robin, Sun Hee Lee; Thevenet, Nicolas; Depenweiller, Christian; Le Tallec, Philippe; Ortholan, Cecile; Aimone, Nicole; Baldeschi, Carine; Cantelli, Andree; Estivalet, Stephane; Le Prince, Cyrille; QUERO, Laurent; Costa, Andre; Gerard, Jean-Pierre; Ardiet, Jean-Michel; Bensadoun, Rene-Jean; Bourhis, Jean; Calais, Gilles; Lartigau, Eric; Ginot, Aurelie; Girard, Nicolas; Mornex, Francoise; Bolla, Michel; Chauvet, Bruno; Maingon, Philippe; Martin, Etienne; Azria, David; Gerard, Jean-Pierre; Grehange, Gilles; Hennequin, Christophe; Peiffert, Didier; Toledano, Alain; Belkacemi, Yazid; Courdi, Adel; Belliere, Aurelie; Peignaux, Karine; Mahe, Marc; Bondiau, Pierre-Yves; Kantor, Guy; Lepechoux, Cecile; Carrie, Christian; Claude, Line

    2007-01-01

    In order to optimize quality and security in the delivery of radiation treatment, the French SFRO (Societe francaise de radiotherapie oncologique) is publishing a Guide for Radiotherapy. This guide is realized according to the HAS (Haute Autorite de sante) methodology of 'structured experts consensus'. This document is made of two parts: a general description of external beam radiation therapy and chapters describing the technical procedures of the main tumors to be irradiated (24). For each procedure, a special attention is given to dose constraints in the organs at risk. This guide will be regularly updated

  9. Charge collection in an external proton beam

    International Nuclear Information System (INIS)

    Wookey, C.W.; Somswasdi, B.; Rouse, J.L.

    1982-01-01

    Results from the measurement of the stability of charge collected from the target and exit foil, or as alternatives, the γ-ray or backscattered proton counts from the exit foil and the Ar X-ray counts from the air path in an external proton beam are presented. These results show that comparative analysis of material mounted in air is reliable, using either the collected charge or the γ-ray counts as the normalizing factor, if there are no earthed objects in close geometry. The backscattered proton counts can also be used, but not the Ar X-ray counts, unless the current is stabilized. The electrical or thermal conductivity of the target and the target to exit foil separation do not affect the proportionality of the collected charge and the γ-ray counts to the charge incident on the target

  10. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  11. External Beam Radiation in Differentiated Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Salem Billan

    2016-01-01

    Full Text Available The treatment of differentiated thyroid carcinoma (DTC is surgery followed in some cases by adjuvant treatment, mostly with radioactive iodine (RAI. External beam radiotherapy (EBRT is less common and not a well-established treatment modality in DTC. The risk of recurrence depends on three major prognostic factors: extra-thyroid extension, patient’s age, and tumor with reduced iodine uptake. Increased risk for recurrence is a major factor in the decision whether to treat the patient with EBRT. Data about the use of EBRT in DTC are limited to small retrospective studies. Most series have demonstrated an increase in loco-regional control. The risk/benefit from giving EBRT requires careful patient selection. Different scoring systems have been proposed by different investigators and centers. The authors encourage clinicians treating DTC to become familiarized with those scoring systems and to use them in the management of different cases. The irradiated volume should include areas of risk for microscopic disease. Determining those areas in each case can be difficult and requires detailed knowledge of the surgery and pathological results, and also understanding of the disease-spreading pattern. Treatment with EBRT in DTC can be beneficial, and data support the use of EBRT in high-risk patients. Randomized controlled trials are needed for better confirmation of the role of EBRT.

  12. External beam radiotherapy for rectal adenocarcinoma

    International Nuclear Information System (INIS)

    Taylor, R.E.; Kerr, G.R.; Arnott, S.J.

    1987-01-01

    A series of 243 patients with adenocarcinoma of the rectum treated with radiotherapy is presented. Radiotherapy was combined with 5-fluorouracil, or given alone. Seventy-four patients were treated with radical external beam radiotherapy for recurrent or inoperable rectal adenocarcinoma. One hundred and forty-five patients with advanced pelvic tumours or metastases were treated with palliative pelvic radiotherapy. Twenty-four patients with small-volume residual pelvic tumour or who were felt to be at high risk of pelvic recurrence following radical resection received postoperative radiotherapy. Complete tumour regression was seen in 38% of radically treated patients, and 24% of palliatively treated patients. Partial regression was observed in 56% of radically treated patients, and 58% of palliatively treated patients. Long-term local tumour control was more commonly observed for small tumours (< 5 cm diameter). Fifty-eight % of patients treated with postoperative radiotherapy remained free of local recurrence. Survival was significantly better with small tumours. The addition of 5FU did not appear to improve survival or tumour control. (author)

  13. Preoperative infusional chemoradiation and surgery with or without an electron beam intraoperative boost for advanced primary rectal cancer

    International Nuclear Information System (INIS)

    Weinstein, Geoffrey D.; Rich, Tyvin A.; Shumate, Charles R.; Skibber, John M.; Cleary, Karen R.; Ajani, Jaffer A.; Ota, David M.

    1995-01-01

    Purpose: To compare the multimodality treatment results of surgical resection plus preoperative radiotherapy with concomitant protracted infusion chemotherapy (preop-chemoXRT), with or without an electron beam intraoperative radiotherapy (EB-IORT) boost, in 37 patients having advanced primary rectal cancer, with the results of a protocol using only preoperative radiotherapy (preop-XRT) plus surgical resection in a historic control group of 36 patients. Methods and Materials: Thirty-eight patients with tethered T3 or T4 primary rectal cancer were treated with 45 Gy delivered in 25 fractions over 5 weeks plus infusional chemotherapy. Thirty-seven patients underwent surgical resection: 13 (35%) had restorative operations, and the remainder had either abdomino-perineal resection (APR) or pelvic exenteration (PE). Electron beam intraoperative radiotherapy (EB-IORT) was used in doses of 10-20 Gy for 11 patients with adherent pelvic tumor. In the 36 historic control patients, the preop-XRT dose was 45 Gy, and 93% of them had APR or PE. Results: The local recurrence rate was 3% for the preop-chemoXRT group and 33% for the historic control group. The 3-year survival rate for patients treated with preop-chemoXRT plus resection was 82% compared with 62% for the historic control group. Distant metastases occurred more frequently in patients treated with an EB-IORT boost than in patients who were not (64% vs. 19%, p < 0.05), and the overall 3-year survival rate was lower for the former (67% vs. 96%, p < 0.05). Acute and late toxicities were acceptable. Conclusions: Preop-chemoXRT for advanced primary rectal cancer results in better control of pelvic disease and better overall survival rates than does preop-XRT alone. With preop-chemoXRT, acute chemoradiation toxicity is increased whereas late morbidity is unchanged compared with preop-XRT alone. Local control in patients with areas of residual or clinically adherent disease is improved by the use of EB-IORT; however, patients

  14. Anesthesia for pediatric external beam radiation therapy

    International Nuclear Information System (INIS)

    Fortney, Jennifer T.; Halperin, Edward C.; Hertz, Caryn M.; Schulman, Scott R.

    1999-01-01

    Background: For very young patients, anesthesia is often required for radiotherapy. This results in multiple exposures to anesthetic agents over a short period of time. We report a consecutive series of children anesthetized for external beam radiation therapy (EBRT). Methods: Five hundred twelve children ≤ 16 years old received EBRT from January 1983 to February 1996. Patient demographics, diagnosis, anesthesia techniques, monitoring, airway management, complications, and outcome were recorded for the patients requiring anesthesia. Results: One hundred twenty-three of the 512 children (24%) required 141 courses of EBRT with anesthesia. Anesthetized patients ranged in age from 20 days to 11 years (mean 2.6 ± 1.8 ). The frequency of a child receiving EBRT and requiring anesthesia by age cohort was: ≤ 1 year (96%), 1-2 years (93%), 2-3 years (80%), 3-4 years (51%), 4-5 years (36%), 5-6 years (13%), 6-7 years (11%), and 7-16 years (0.7%). Diagnoses included: primary CNS tumor (28%), retinoblastoma (27%), neuroblastoma (20%), acute leukemia (9%), rhabdomyosarcoma (6%), and Wilms' tumor (4%). Sixty-three percent of the patients had been exposed to chemotherapy prior to EBRT. The mean number of anesthesia sessions per patient was 22 ± 16. Seventy-eight percent of the treatment courses were once daily and 22% were twice daily. Anesthesia techniques included: short-acting barbiturate induction + inhalation maintenance (21%), inhalation only (20%), ketamine (19%), propofol only (12%), propofol induction + inhalation maintenance (7%), ketamine induction + inhalation maintenance (6%), ketamine or short-acting barbiturate induction + inhalation maintenance (6%). Monitoring techniques included: EKG (95%), O 2 saturation (93%), fraction of inspired O 2 (57%), and end-tidal CO 2 (55%). Sixty-four percent of patients had central venous access. Eleven of the 74 children with a central line developed sepsis (15%): 6 of the 11 were anesthetized with propofol (55%), 4 with a

  15. Shear behavior of concrete beams externally prestressed with Parafil ropes

    Directory of Open Access Journals (Sweden)

    A.H. Ghallab

    2013-03-01

    Full Text Available Although extensive work has been carried out investigating the use of external prestressing system for flexural strengthening, a few studies regarding the shear behavior of externally prestressed beams can be found. Five beams, four of them were externally strengthened using Parafil rope, were loaded up to failure to investigate the effect of shear span/depth ratio, external prestressing force and concrete strength on their shear behavior. Test results showed that the shear span to depth ratio has a significant effect on both the shear strength and failure mode of the strengthened beams and the presence of external prestressing force increased the ultimate load of the tested beams by about 75%. Equations proposed by different codes for both the conventional reinforced concrete beams and for ordinary prestressed beams were used to evaluate the obtained experimental results. In general, codes equations showed a high level of conservatism in predicting the shear strength of the beams. Also, using the full strength rather than half of the concrete shear strength in the Egyptian code PC-method improves the accuracy of the calculated ultimate shear strength.

  16. External beam pixe programs at the University of California, Davis

    International Nuclear Information System (INIS)

    Eldred, R.A.

    1983-01-01

    A PIXE system in which large or delicate samples are excited by a low-current external proton beam is described. This system has been used to analyze historical printed books and manuscripts, as well as a large variety of archeological artifacts. The steps used to protect the sample from unnecessary beam current are examined. A recent thorough study of the first volume of the Gutenberg 42-line Bible is described in some detail

  17. External beam radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Forman, Jeffrey D.

    1996-01-01

    Purpose/Objectives: The intent of this course is to review the issues involved in the management of non-metastatic adenocarcinoma of the prostate. -- The value of pre-treatment prognostic factors including stage, grade and PSA value will be presented, and their value in determining therapeutic strategies will be discussed. -- Controversies involving the simulation process and treatment design will be presented. The value of CT scanning, Beams-Eye View, 3-D planning, intravesicle, intraurethral and rectal contrast will be presented. The significance of prostate and patient movement and strategies for dealing with them will be presented. -- The management of low stage, low to intermediate grade prostate cancer will be discussed. The dose, volume and timing of irradiation will be discussed as will the role of neo-adjuvant hormonal therapy, neutron irradiation and brachytherapy. The current status of radical prostatectomy and cryotherapy will be summarized. Treatment of locally advanced, poorly differentiated prostate cancer will be presented including a discussion of neo-adjuvant and adjuvant hormones, dose-escalation and neutron irradiation. -- Strategies for post-radiation failures will be presented including data on cryotherapy, salvage prostatectomy and hormonal therapy (immediate, delayed and/or intermittent). New areas for investigation will be reviewed. -- The management of patients post prostatectomy will be reviewed. Data on adjuvant radiation and therapeutic radiation for biochemical or clinically relapsed patients will be presented. This course hopes to present a realistic and pragmatic overview for treating patients with non-metastatic prostatic cancer

  18. Study on external beam radiation therapy

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT

  19. Study on external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT.

  20. RC T-Beams Externally Prestressed with Unbonded CFRP

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Bennitz, Anders; Nilimaa, Jonny

    2010-01-01

    An experimental test series with seven beams externally prestressed with unbonded CFRP 7 (Carbon Fibre Reinforced Polymer) tendons has been performed. Presence of deviator, initial 8 tendon depth and prestressing force are varied. Results and behaviors are compared to 9 common beam theory, matching...... beams prestressed with steel tendons and a model taken 10 from literature to predict the beams behaviour. The test set-up include a newly developed 11 anchorage and post-tensioning system. From the evaluation it can be seen that CFRP and 12 steel tendons influence the strengthened beams structural...... was not as accurately modeled. 16 Deflection at failure is seen to be related to the number of flexural cracks formed within the 17 constant moment region....

  1. Development and Commissioning of an External Beam Facility in the Union College Ion Beam Analysis Laboratory

    Science.gov (United States)

    Yoskowitz, Joshua; Clark, Morgan; Labrake, Scott; Vineyard, Michael

    2015-10-01

    We have developed an external beam facility for the 1.1-MV tandem Pelletron accelerator in the Union College Ion Beam Analysis Laboratory. The beam is extracted from an aluminum pipe through a 1 / 4 ' ' diameter window with a 7.5- μm thick Kapton foil. This external beam facility allows us to perform ion beam analysis on samples that cannot be put under vacuum, including wet samples and samples too large to fit into the scattering chamber. We have commissioned the new facility by performing proton induced X-ray emission (PIXE) analysis of several samples of environmental interest. These include samples of artificial turf, running tracks, and a human tooth with an amalgam filling. A 1.7-MeV external proton beam was incident on the samples positioned 2 cm from the window. The resulting X-rays were measured using a silicon drift detector and were analyzed using GUPIX software to determine the concentrations of elements in the samples. The results on the human tooth indicate that while significant concentrations of Hg, Ag, and Sn are present in the amalgam filling, only trace amounts of Hg appear to have leached into the tooth. The artificial turf and running tracks show rather large concentrations of a broad range of elements and trace amounts of Pb in the turf infill.

  2. External-beam irradiation of carcinoma of the penis

    International Nuclear Information System (INIS)

    Sagerman, R.H.; Yu, W.S.; Chung, C.T.; Puranik, A.

    1984-01-01

    Twenty-four patients with biopsy-proved squamous-cell carcinoma of the penis underwent external-beam radiation therapy between 1966 and 1980. Fifteen were treated for the primary tumor and 9 for metastatic inguinal lymphadenopathy; no patient received prophylactic nodal irradiation. Seven out of 9 tumors in stage I, 2/3 in stage II, and 1/3 in stage IV were controlled for three years. Control of fixed, inoperable groin nodes was poor, and none of these patients survived beyond 1 1/2 years

  3. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: calli@culture.nl; Poirot, J.-P.; Querre, G

    1999-04-02

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations.

  4. Trace element fingerprinting of jewellery rubies by external beam PIXE

    International Nuclear Information System (INIS)

    Calligaro, T.; Poirot, J.-P.; Querre, G.

    1999-01-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations

  5. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Science.gov (United States)

    Calligaro, T.; Poirot, J.-P.; Querré, G.

    1999-04-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies : one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional gemological observations.

  6. [External beam radiotherapy cone beam-computed tomography-based dose calculation].

    Science.gov (United States)

    Barateau, A; Céleste, M; Lafond, C; Henry, O; Couespel, S; Simon, A; Acosta, O; de Crevoisier, R; Périchon, N

    2018-02-01

    In external beam radiotherapy, the dose planning is currently based on computed tomography (CT) images. A relation between Hounsfield numbers and electron densities (or mass densities) is necessary for dose calculation taking heterogeneities into account. In image-guided radiotherapy process, the cone beam CT is classically used for tissue visualization and registration. Cone beam CT for dose calculation is also attractive in dose reporting/monitoring perspectives and particularly in a context of dose-guided adaptive radiotherapy. The accuracy of cone beam CT-based dose calculation is limited by image characteristics such as quality, Hounsfield numbers consistency and restrictive sizes of volume acquisition. The analysis of the literature identifies three kinds of strategies for cone beam CT-based dose calculation: establishment of Hounsfield numbers versus densities curves, density override to regions of interest, and deformable registration between CT and cone beam CT images. Literature results show that discrepancies between the reference CT-based dose calculation and the cone beam CT-based dose calculation are often lower than 3%, regardless of the method. However, they can also reach 10% with unsuitable method. Even if the accuracy of the cone beam CT-based dose calculation is independent of the method, some strategies are promising but need improvements in the automating process for a routine implementation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  7. UCN Source at an External Beam of Thermal Neutrons

    Directory of Open Access Journals (Sweden)

    E. V. Lychagin

    2015-01-01

    Full Text Available We propose a new method for production of ultracold neutrons (UCNs in superfluid helium. The principal idea consists in installing a helium UCN source into an external beam of thermal or cold neutrons and in surrounding this source with a solid methane moderator/reflector cooled down to ~4 K. The moderator plays the role of an external source of cold neutrons needed to produce UCNs. The flux of accumulated neutrons could exceed the flux of incident neutrons due to their numerous reflections from methane; also the source size could be significantly larger than the incident beam diameter. We provide preliminary calculations of cooling of neutrons. These calculations show that such a source being installed at an intense source of thermal or cold neutrons like the ILL or PIK reactor or the ESS spallation source could provide the UCN density 105 cm−3, the production rate 107 UCN/s−1. Main advantages of such an UCN source include its low radiative and thermal load, relatively low cost, and convenient accessibility for any maintenance. We have carried out an experiment on cooling of thermal neutrons in a methane cavity. The data confirm the results of our calculations of the spectrum and flux of neutrons in the methane cavity.

  8. External-beam PIXE analysis of small sculptures

    Energy Technology Data Exchange (ETDEWEB)

    Gyodi, I.; Demeter, I.; Hollos-Nagy, K.; Kovacs, I.; Szokefalvi-Nagy, Z. E-mail: sznagy@rmki.kfki.hu

    1999-04-02

    Non-destructive analysis of precious art objects is an important tool to solve provenance problems or to facilitate restoration. External beam PIXE analysis is one of the most powerful and popular methods used in this respect. The paper summarises the external beam PIXE set-up at the Accelerator Laboratory in Budapest, and two selected applications are described. Different parts of a small Cambodian metal sculpture probably made in the 11th century were analysed. It was observed that the sculpture was composed of an iron core and an outer bronze shell. This sculptural technique was well known in the Middle-East but no indication has been found about its use in the Far-East, yet. Before its restoration paint traces on a wooden relief of St. Jerome made by an unknown artist in about 1600 were analysed. Different white and red paints were distinguished at selected points and the presence of titanium on a certain part of the relief was attributed to a repainting in modern times.

  9. Bilateral Rhegmatogenous Retinal Detachment during External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Takako Hidaka

    2016-06-01

    Full Text Available Herein, we report a case of nontraumatic bilateral rhegmatogenous retinal detachment (RRD during external beam radiotherapy for nonocular tumor, presented as an observational case study in conjunction with a review of the relevant literature. A 65-year-old male was referred to our hospital due to bilateral RRD. He underwent a biopsy for a tumor of the left frontal lobe 4 months prior to presentation, and the tumor had been diagnosed as primary central nerve system B-cell type lymphoma. He received chemotherapy and external beam radiotherapy for 1 month. There were no traumatic episodes. Bilateral retinal detachment occurred during a series of radiotherapies. Simultaneous nontraumatic bilateral retinal detachment is rare. The effects of radiotherapy on ocular functionality, particularly in cases involving retinal adhesion and vitreous contraction, may include RRD. Thus, it is necessary to closely monitor the eyes of patients undergoing radiotherapy, particularly those undergoing surgery for retinal detachment and those with a history of photocoagulation for retinal tears, a relevant family history, or risk factors known to be associated with RRD.

  10. A Phase 1/2 and Biomarker Study of Preoperative Short Course Chemoradiation With Proton Beam Therapy and Capecitabine Followed By Early Surgery for Resectable Pancreatic Ductal Adenocarcinoma

    International Nuclear Information System (INIS)

    Hong, Theodore S.; Ryan, David P.; Borger, Darrell R.; Blaszkowsky, Lawrence S.; Yeap, Beow Y.; Ancukiewicz, Marek; Deshpande, Vikram; Shinagare, Shweta; Wo, Jennifer Y.; Boucher, Yves; Wadlow, Raymond C.; Kwak, Eunice L.; Allen, Jill N.; Clark, Jeffrey W.; Zhu, Andrew X.; Ferrone, Cristina R.; Mamon, Harvey J.; Adams, Judith; Winrich, Barbara; Grillo, Tarin

    2014-01-01

    Purpose: To evaluate the safety, efficacy and biomarkers of short-course proton beam radiation and capecitabine, followed by pancreaticoduodenectomy in a phase 1/2 study in pancreatic ductal adenocarcinoma (PDAC) patients. Methods and Materials: Patients with radiographically resectable, biopsy-proven PDAC were treated with neoadjuvant short-course (2-week) proton-based radiation with capecitabine, followed by surgery and adjuvant gemcitabine. The primary objective was to demonstrate a rate of toxicity grade ≥3 of <20%. Exploratory biomarker studies were performed using surgical specimen tissues and peripheral blood. Results: The phase 2 dose was established at 5 daily doses of 5 GyE. Fifty patients were enrolled, of whom 35 patients were treated in the phase 2 portion. There were no grade 4 or 5 toxicities, and only 2 of 35 patients (4.1%) experienced a grade 3 toxicity event (chest wall pain grade 1, colitis grade 1). Of 48 patients eligible for analysis, 37 underwent pancreaticoduodenectomy. Thirty of 37 (81%) had positive nodes. Locoregional failure occurred in 6 of 37 resected patients (16.2%), and distant recurrence occurred in 35 of 48 patients (72.9%). With median follow-up of 38 months, the median progression-free survival for the entire group was 10 months, and overall survival was 17 months. Biomarker studies showed significant associations between worse survival outcomes and the KRAS point mutation change from glycine to aspartic acid at position 12, stromal CXCR7 expression, and circulating biomarkers CEA, CA19-9, and HGF (all, P<.05). Conclusions: This study met the primary endpoint by showing a rate of 4.1% grade 3 toxicity for neoadjuvant short-course proton-based chemoradiation. Treatment was associated with favorable local control. In exploratory analyses, KRAS G12D status and high CXCR7 expression and circulating CEA, CA19-9, and HGF levels were associated with poor survival

  11. Computerized treatment planning systems for external photon beam radiotherapy

    International Nuclear Information System (INIS)

    Evans, M.D.C.

    2005-01-01

    Computerized treatment planning systems (TPSs) are used in external beam radiotherapy to generate beam shapes and dose distributions with the intent to maximize tumour control and minimize normal tissue complications. Patient anatomy and tumour targets can be represented as 3-D models. The entire process of treatment planning involves many steps and the medical physicist is responsible for the overall integrity of the computerized TPS to accurately and reliably produce dose distributions and associated calculations for external beam radiotherapy. The planning itself is most commonly carried out by a dosimetrist, and the plan must be approved by a radiation oncologist before implementation in actual patient treatments. Treatment planning prior to the 1970s was generally carried out through the manual manipulation of standard isodose charts on to patient body contours that were generated by direct tracing or lead wire representation, and relied heavily on the judicious choice of beam weight and wedging by an experienced dosimetrist. The simultaneous development of computed tomography (CT), along with the advent of readily accessible computing power from the 1970s on, led to the development of CT based computerized treatment planning, providing the ability to view dose distributions directly superimposed upon a patient's axial anatomy. The entire treatment planning process involves many steps, beginning from beam data acquisition and entry into the computerized TPS, through patient data acquisition, to treatment plan generation and the final transfer of data to the treatment machine. Successive improvements in treatment planning hardware and software have been most notable in the graphics, calculation and optimization aspects of current systems. Systems encompassing the 'Virtual Patient' are able to display beam's eye views (BEVs) of radiation beams and digitally reconstructed radiographs (DRRs) for arbitrary dose distributions. Dose calculations have evolved from

  12. Parallel processing of dose calculation for external photon beam therapy

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Ando, Yutaka; Tsukamoto, Nobuhiro; Ito, Hisao; Kubo, Atsushi

    1994-01-01

    We implemented external photon beam dose calculation programs into a parallel processor system consisting of Transputers, 32-bit processors especially suitable for multi-processor configuration. Two network conformations, binary-tree and pipeline, were evaluated for rectangular and irregular field dose calculation algorithms. Although computation speed increased in proportion to the number of CPU, substantial overhead caused by inter-processor communication occurred when a smaller computation load was delivered to each processor. On the other hand, for irregular field calculation, which requires more computation capability for each calculation point, the communication overhead was still less even when more than 50 processors were involved. Real-time responses could be expected for more complex algorithms by increasing the number of processors. (author)

  13. Olfactory neural tumours - the role of external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Slevin, N.J.; Irwin, C.J.R.; Banerjee, S.S.; Path, F.R.C.; Gupta, N.K.; Farrington, W.T. [Christie Hospital and Holt Radium Inst., Manchester (United Kingdom)

    1996-11-01

    Olfactory neuroblastoma is an uncommon tumour arising in the nasal cavity or paranasal sinuses. We report the management of nine cases treated with external beam radiotherapy subsequent to surgery, either attempted definitive removal or biopsy only. Recent refinements in pathological evaluation of these tumours are discussed. Seven cases were deemed classical olfactory neuroblastoma whilst two were classified as neuroendocrine carcinoma. The clinical features, radiotherapy technique and variable natural history are presented. Seven of eight patients treated radically were controlled locally, with a minimum follow-up of two years. Three patients developed cervical lymph node disease and three patients died of systemic metastatic disease. Suggestions are made as to which patients should have en-bloc resection rather than definitive radiotherapy. (author).

  14. Improving external beam radiotherapy by combination with internal irradiation.

    Science.gov (United States)

    Dietrich, A; Koi, L; Zöphel, K; Sihver, W; Kotzerke, J; Baumann, M; Krause, M

    2015-07-01

    The efficacy of external beam radiotherapy (EBRT) is dose dependent, but the dose that can be applied to solid tumour lesions is limited by the sensitivity of the surrounding tissue. The combination of EBRT with systemically applied radioimmunotherapy (RIT) is a promising approach to increase efficacy of radiotherapy. Toxicities of both treatment modalities of this combination of internal and external radiotherapy (CIERT) are not additive, as different organs at risk are in target. However, advantages of both single treatments are combined, for example, precise high dose delivery to the bulk tumour via standard EBRT, which can be increased by addition of RIT, and potential targeting of micrometastases by RIT. Eventually, theragnostic radionuclide pairs can be used to predict uptake of the radiotherapeutic drug prior to and during therapy and find individual patients who may benefit from this treatment. This review aims to highlight the outcome of pre-clinical studies on CIERT and resultant questions for translation into the clinic. Few clinical data are available until now and reasons as well as challenges for clinical implementation are discussed.

  15. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  16. Combined external beam and intraluminal radiotherapy for irresectable Klatskin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Schleicher, U.M. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); Staatz, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Alzen, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Abt. Kinderradiologie, Giessen Univ. (Germany); Andreopoulos, D. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); BOC Oncology Centre, Nikosia (Cyprus)

    2002-12-01

    Background: In most cases of proximal cholangiocarcinoma, curative surgery is not possible. Radiotherapy can be used for palliative treatment. We report our experience with combined external beam and intraluminal radiotherapy of advanced Klatskin's tumors. Patients and Methods: 30 patients were treated for extrahepatic proximal bile duct cancer. Our schedule consisted for external beam radiotherapy (median dose 30 Gy) and a high-dose-rate brachytherapy boost (median dose 40 Gy) delivered in four or five fractions, which could be applied completely in twelve of our patients. 15 patients in the brachytherapy and nine patients in the non-brachytherapy group received additional low-dose chemotherapy with 5-fluorouracil. Results: The brachytherapy boost dose improved the effect of external beam radiotherapy by increasing survival from a median of 3.9 months in the non-brachytherapy group to 9.1 months in the brachytherapy group. The effect was obvious in patients receiving a brachytherapy dose above 30 Gy, and in those without jaundice at the beginning of radiotherapy (p<0.05). Conclusions: The poor prognosis in patients with advanced Klatskin's tumors may be improved by combination therapy, with the role of brachytherapy and chemotherapy still to be defined. Our results suggest that patients without jaundice should be offered brachytherapy, and that a full dose of more than 30 Gy should be applied. (orig.) [German] Hintergrund: Bei den meisten Patienten mit proximalen Cholangiokarzinomen ist eine kurative Operation nicht mehr moeglich. Im Rahmen der Palliativbehandlung kann die Strahlentherapie eingesetzt werden. Wir berichten ueber unsere Erfahrungen mit der Kombination aus perkutaner und intraluminaler Strahlentherapie fortgeschrittener Klatskin-Tumoren. Patienten und Methode: 30 Patienten wurden wegen extrahepatischer proximaler Gallengangskarzinome behandelt. Unser Therapieschema umfasste eine perkutane Strahlentherapie (mediane Dosis: 30 Gy) sowie einen

  17. A Phase 1/2 and Biomarker Study of Preoperative Short Course Chemoradiation With Proton Beam Therapy and Capecitabine Followed By Early Surgery for Resectable Pancreatic Ductal Adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Theodore S., E-mail: tshong1@partners.org [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ryan, David P.; Borger, Darrell R.; Blaszkowsky, Lawrence S.; Yeap, Beow Y. [Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ancukiewicz, Marek [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Deshpande, Vikram; Shinagare, Shweta [Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Wo, Jennifer Y.; Boucher, Yves [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Wadlow, Raymond C.; Kwak, Eunice L.; Allen, Jill N.; Clark, Jeffrey W.; Zhu, Andrew X. [Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ferrone, Cristina R. [Department of Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Mamon, Harvey J. [Department of Radiation Oncology, Brigham and Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Adams, Judith; Winrich, Barbara; Grillo, Tarin [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); and others

    2014-07-15

    Purpose: To evaluate the safety, efficacy and biomarkers of short-course proton beam radiation and capecitabine, followed by pancreaticoduodenectomy in a phase 1/2 study in pancreatic ductal adenocarcinoma (PDAC) patients. Methods and Materials: Patients with radiographically resectable, biopsy-proven PDAC were treated with neoadjuvant short-course (2-week) proton-based radiation with capecitabine, followed by surgery and adjuvant gemcitabine. The primary objective was to demonstrate a rate of toxicity grade ≥3 of <20%. Exploratory biomarker studies were performed using surgical specimen tissues and peripheral blood. Results: The phase 2 dose was established at 5 daily doses of 5 GyE. Fifty patients were enrolled, of whom 35 patients were treated in the phase 2 portion. There were no grade 4 or 5 toxicities, and only 2 of 35 patients (4.1%) experienced a grade 3 toxicity event (chest wall pain grade 1, colitis grade 1). Of 48 patients eligible for analysis, 37 underwent pancreaticoduodenectomy. Thirty of 37 (81%) had positive nodes. Locoregional failure occurred in 6 of 37 resected patients (16.2%), and distant recurrence occurred in 35 of 48 patients (72.9%). With median follow-up of 38 months, the median progression-free survival for the entire group was 10 months, and overall survival was 17 months. Biomarker studies showed significant associations between worse survival outcomes and the KRAS point mutation change from glycine to aspartic acid at position 12, stromal CXCR7 expression, and circulating biomarkers CEA, CA19-9, and HGF (all, P<.05). Conclusions: This study met the primary endpoint by showing a rate of 4.1% grade 3 toxicity for neoadjuvant short-course proton-based chemoradiation. Treatment was associated with favorable local control. In exploratory analyses, KRAS{sup G12D} status and high CXCR7 expression and circulating CEA, CA19-9, and HGF levels were associated with poor survival.

  18. Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Jabbour, Salma K.; Kim, Sinae; Haider, Syed A.; Xu, Xiaoting; Wu, Alson; Surakanti, Sujani; Aisner, Joseph; Langenfeld, John; Yue, Ning J.; Haffty, Bruce G.; Zou, Wei

    2015-01-01

    Purpose: We sought to evaluate whether tumor response using cone beam computed tomography (CBCT) performed as part of the routine care during chemoradiation therapy (CRT) could forecast the outcome of unresectable, locally advanced, non-small cell lung cancer (NSCLC). Methods and Materials: We manually delineated primary tumor volumes (TV) of patients with NSCLC who were treated with radical CRT on days 1, 8, 15, 22, 29, 36, and 43 on CBCTs obtained as part of the standard radiation treatment course. Percentage reductions in TV were calculated and then correlated to survival and pattern of recurrence using Cox proportional hazard models. Clinical information including histologic subtype was also considered in the study of such associations. Results: We evaluated 38 patients with a median follow-up time of 23.4 months. The median TV reduction was 39.3% (range, 7.3%-69.3%) from day 1 (D1) to day 43 (D43) CBCTs. Overall survival was associated with TV reduction from D1 to D43 (hazard ratio [HR] 0.557, 95% CI 0.39-0.79, P=.0009). For every 10% decrease in TV from D1 to D43, the risk of death decreased by 44.3%. For patients whose TV decreased ≥39.3 or <39.3%, log-rank test demonstrated a separation in survival (P=.02), with median survivals of 31 months versus 10 months, respectively. Neither local recurrence (HR 0.791, 95% CI 0.51-1.23, P=.29), nor distant recurrence (HR 0.78, 95% CI 0.57-1.08, P=.137) correlated with TV decrease from D1 to D43. Histologic subtype showed no impact on our findings. Conclusions: TV reduction as determined by CBCT during CRT as part of routine care predicts post-CRT survival. Such knowledge may justify intensification of RT or application of additional therapies. Assessment of genomic characteristics of these tumors may permit a better understanding of behavior or prediction of therapeutic outcomes

  19. Normal tissue tolerance to external beam radiation therapy: The mandible

    International Nuclear Information System (INIS)

    Berger, A.; Bensadoun, R.J.

    2010-01-01

    Describing dose constraints for organs at risk in external beam radiotherapy is a key-point in order to maximize the therapeutic ratio. In head and neck irradiation, mandible is frequently exposed to ionising radiation-related complications. Those complications will be exposed after a short description of anatomical and physiopathological aspects. A literature search was performed using the Pubmed-Medline database, with following keywords (Osteoradionecrosis, Radiotherapy, Mandible, Toxicity, Organ at risk, Trismus). Incidence and dose constraints will be reported. The incidence of osteoradionecrosis decreased since the 1990, but it remains a dreaded late complication of head and neck cancer radiotherapy. It essentially occurs with cumulative doses of 66 Gy on the mandible (standard fractionation) applied to a significant volume. Respecting oral care is crucial to avoid this kind of complication. The respect of the dose-constraint described should not lead to under treat tumor bed in a curative intent. Trismus related to ionising radiation is poorly described. Literature data cannot lead to describe precise dose constraints. (authors)

  20. Cracking of Beams Strengthened with Externally Bonded SRP Tapes

    Science.gov (United States)

    Krzywoń, Rafał

    2017-10-01

    Paper discusses strengthening efficiency of relatively new kind of SRP composite based on high strength steel wires. They are made of ultra-high strength steel primarily used in cords of car tires. Through advanced treatment, the mechanical properties of SRP steel are similar to other high carbon cold drawn steels used in construction industry. Strength significantly exceed 2000 MPa, there is no perfect plasticity at yield stress level. Almost linear stress-strain relationship makes SRP steel mechanical properties similar to carbon fibers. Also flexibility and weight ratio of the composite overlay is slightly worse than CFRP strip. Despite these advantages SRP is not as popular as other composites reinforced with fibers of high strength. This is due to the small number of studies of SRP behavior and applicability. Paper shows selected results of the laboratory test of beams strengthened with use of SRP and CFRP externally bonded overlays. Attention has been focused primarily on the phenomenon of cracking. Comparison include the cracking moment, crack width and spacing, coverage of crack zone. Despite the somewhat lower rigidity of SRP tapes, they have a much better adhesion to concrete, so that the crack width is comparable in almost the whole load range. The paper also includes an assessment of the common methods of checking the condition of cracking in relation to the tested SRP strengthening. The paper presents actual calculation procedures to determine the crack spacing and crack width. The discussed formulas are verified with results of provided laboratory tests.

  1. Externally Prestressed Monolithic and Segmental Concrete Beams under Torsion: a Comparative Finite Element Study

    Energy Technology Data Exchange (ETDEWEB)

    Al-Gorafi, M A; Ali, A A A; Jaafar, M S [Department of Civil Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Othman, I [Department of Civil Engineering, University Of Malaya, 50603 Kuala Lumpur (Malaysia); Anwar, M P, E-mail: gorafimg@gmail.com [Housing Research Centre, University Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)

    2011-02-15

    Externally Prestressed segmental beams are widely used in the construction of bridge structures today. These beams have many attractive advantages for rehabilitation and strengthening of existing structures as well. However, segmental beams experience significant effect under combined stresses at the joint interfaces between segments. This paper presents a finite element study on the effect of torsion on the structural behavior of both external prestressed monolithic and segmental concrete beams. Geometric and material nonlinearities were included in the study. The results show significant difference in the behavior of monolithic and segmental beams under torsion.

  2. Externally Prestressed Monolithic and Segmental Concrete Beams under Torsion: a Comparative Finite Element Study

    Science.gov (United States)

    Al-Gorafi, M. A.; Ali, A. A. A.; Othman, I.; Jaafar, M. S.; Anwar, M. P.

    2011-02-01

    Externally Prestressed segmental beams are widely used in the construction of bridge structures today. These beams have many attractive advantages for rehabilitation and strengthening of existing structures as well. However, segmental beams experience significant effect under combined stresses at the joint interfaces between segments. This paper presents a finite element study on the effect of torsion on the structural behavior of both external prestressed monolithic and segmental concrete beams. Geometric and material nonlinearities were included in the study. The results show significant difference in the behavior of monolithic and segmental beams under torsion.

  3. Severe dry-eye syndrome following external beam irradiation

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-01-01

    There are limited data in the literature on the probability of dry-eye complications according to radiotherapy dose. This study investigates the risk of radiation-induced severe dry-eye syndrome in patients in whom an entire orbit was exposed to fractionated external beam irradiation. Between October 1964 and May 1989, 33 patients with extracranial head and neck tumors received irradiation of an entire orbit. Most patients were treated with 60 Co. The dose to the lacrimal apparatus was calculated at a depth of 1 cm from the anterior skin surface, the approximate depth of the major lacrimal gland. The end point of the study was severe dry-eye syndrome sufficient to produce visual loss secondary to corneal opacification, ulceration, or vascularization. Twenty patients developed severe dry-eye syndrome. All 17 patients who received dose ≥57Gy developed severe dry-eye syndrome. Three (19%) of 16 patients who received doses ≥45 Gy developed severe dry-eye syndrome; injuries in the latter group were much more slower to develop (4 to 11 years) than in the higher dose group, in whom corneal vascularization and opacification were usually pronounced within 9-10 months. There were no data for the range of doses between 45.01 and 56.99 Gy. The data did not suggest an increased risk of severe dry-eye syndrome with increasing age. Data from the current series and the literature are combined to construct a sigmoid dose response curve. The incidence of injury increases from 0% reported after doses ≥30 Gy to 100% after doses ≥57 Gy. 13 refs., 3 figs., 5 tabs

  4. External Beam Radiotherapy for Colon Cancer: Patterns of Care

    International Nuclear Information System (INIS)

    Dunn, Emily F.; Kozak, Kevin R.; Moody, John S.

    2010-01-01

    Purpose: Despite its common and well characterized use in other gastrointestinal malignancies, little is known about radiotherapy (RT) use in nonmetastatic colon cancer in the United States. To address the paucity of data regarding RT use in colon cancer management, we examined the RT patterns of care in this patient population. Methods and Materials: Patients with nonmetastatic colon cancer, diagnosed between 1988 and 2005, were identified in the Surveillance, Epidemiology, and End Results (SEER) database. Univariate and multivariate methods were used to identify factors associated with RT use. Results: On univariate analysis, tumor location, age, sex, race, T stage, N stage, and geographic location were each associated with differences in RT use (all p < 0.01). In general, younger patients, male patients, and patients with more advanced disease were more likely to receive RT. On multivariate analysis, tumor location, age, gender, T and N stage, time of diagnosis and geographic location were significantly associated with RT use (all p < 0.001). Race, however, was not associated with RT use. On multivariate analysis, patients diagnosed in 1988 were 2.5 times more likely to receive RT than those diagnosed in 2005 (p = 0.001). Temporal changes in RT use reflect a responsiveness to evolving evidence related to the therapeutic benefits of adjuvant RT. Conclusions: External beam RT is infrequently used for colon cancer, and its use varies according to patient and tumor characteristics. RT use has declined markedly since the late 1980s; however, it continues to be used for nonmetastatic disease in a highly individualized manner.

  5. Realistic respiratory motion margins for external beam partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Conroy, Leigh; Quirk, Sarah [Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta T2N 4N2 (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4 (Canada); Smith, Wendy L., E-mail: wendy.smith@albertahealthservices.ca [Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta T2N 4N2 (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4 (Canada); Department of Oncology, University of Calgary, Calgary, Alberta T2N 1N4 (Canada)

    2015-09-15

    Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dose profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was

  6. A TCP model for external beam treatment of intermediate-risk prostate cancer.

    LENUS (Irish Health Repository)

    Walsh, Seán

    2013-03-01

    Biological models offer the ability to predict clinical outcomes. The authors describe a model to predict the clinical response of intermediate-risk prostate cancer to external beam radiotherapy for a variety of fractionation regimes.

  7. Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric Cancer

    International Nuclear Information System (INIS)

    Chung, Hans T.; Lee, Brian; Park, Eileen; Lu, Jiade J.; Xia Ping

    2008-01-01

    Purpose: To compare dosimetric endpoints between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) at our center with limited IMRT experience, and to perform an external audit of the IMRT plans. Methods and Materials: Ten patients, who received adjuvant chemoradiation for gastric cancer, formed the study cohort. For standardization, the planning target volume (PTV) and organs at risk were recontoured with the assistance of a study protocol radiologic atlas. The cohort was replanned with CMS Xio to generate coplanar 3D-CRT and IMRT plans. All 10 datasets, including volumes but without the plans (i.e., blinded), were transmitted to an experienced center where IMRT plans were designed using Nomos Corvus (IMRT-C) and ADAC Pinnacle (IMRT-P). All IMRT plans were normalized to D95% receiving 45 Gy. Results: Intensity-modulated radiotherapy yielded higher PTV V45 (volume that receives ≥45 Gy) (p < 0.001) than 3D-CRT. No difference in V20 was seen in the right (p = 0.9) and left (p 0.3) kidneys, but the liver mean dose (p < 0.001) was superior with IMRT. For the external audit, IMRT-C (p = 0.002) and IMRT-P (p < 0.001) achieved significantly lower left kidney V20 than IMRT, and IMRT-P (p < 0.001) achieved lower right kidney V20 than IMRT. The IMRT-C (p = 0.003) but not IMRT-P (p = 0.6) had lower liver mean doses than IMRT. Conclusions: At our institution with early IMRT experience, IMRT improved PTV dose coverage and liver doses but not kidney doses. An external audit of IMRT plans showed that an experienced center can yield superior IMRT plans

  8. Self-Nulling Beam Combiner Using No External Phase Inverter

    Science.gov (United States)

    Bloemhof, Eric E.

    2010-01-01

    A self-nulling beam combiner is proposed that completely eliminates the phase inversion subsystem from the nulling interferometer, and instead uses the intrinsic phase shifts in the beam splitters. Simplifying the flight instrument in this way will be a valuable enhancement of mission reliability. The tighter tolerances on R = T (R being reflection and T being transmission coefficients) required by the self-nulling configuration actually impose no new constraints on the architecture, as two adaptive nullers must be situated between beam splitters to correct small errors in the coatings. The new feature is exploiting the natural phase shifts in beam combiners to achieve the 180 phase inversion necessary for nulling. The advantage over prior art is that an entire subsystem, the field-flipping optics, can be eliminated. For ultimate simplicity in the flight instrument, one might fabricate coatings to very high tolerances and dispense with the adaptive nullers altogether, with all their moving parts, along with the field flipper subsystem. A single adaptive nuller upstream of the beam combiner may be required to correct beam train errors (systematic noise), but in some circumstances phase chopping reduces these errors substantially, and there may be ways to further reduce the chop residuals. Though such coatings are beyond the current state of the art, the mechanical simplicity and robustness of a flight system without field flipper or adaptive nullers would perhaps justify considerable effort on coating fabrication.

  9. Concurrent Cisplatin-Based Chemoradiation in Squamous Cell Carcinoma of Cervix.

    Science.gov (United States)

    Hashmi, Hina; Maqbool, Amir; Ahmed, Saeed; Ahmed, Adeel; Sheikh, Kulsoom; Ahmed, Akhtar

    2016-04-01

    To evaluate the efficacy of cisplatin-based concurrent chemoradiation in squamous cell carcinoma of cervix and the frequency of acute toxicity. Case series. Department of Clinical Oncology, Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, from September 2010 to September 2011. Eighty patients with histologically proven squamous cell carcinoma of cervix were included. Patients were treated with concurrent chemoradiation. External beam radiation was delivered with 50 Gy whole pelvis along with 40 mg/m2 weekly cisplatin followed by brachytherapy three insertions of 6.5 Gy each, one week apart. Response to treatment was assessed using response evaluation criteria in solid tumours (RECIST) criteria at 4 weeks after treatment. Acute toxicity of chemoradiation was assessed using common toxicity criteria. Out of the 80 patients, 8 patients were lost to follow-up. Remaining 72 patients aged 28 - 65 years with mean age of 48.03 ±8.9 years. Forty-eight patients (66%) were in stage II-B, 5 (7%) were in stage III-A, 7 (10%) were in stage III-B, and 12 (17%) were in stage IV-A. Overall response to treatment was 92%, in which 39 (54%) had complete response, and 27 (38%) had partial response while 6 (8%) show progressive disease. About 70% patients had diarrhea, 61.2% patients developed vomiting, 45.8% patients had dermatitis, 43% patients had vaginal mucositis, 40.3% had anemia, 13.9% patients had neutropenia, 27.8% patients had dysuria, and 22.2% patients had proctitis. Cisplatin-based concurrent chemoradiation is an effective treatment in locally advanced stage of cervical cancer with manageable toxicity.

  10. Comparison of radioimmunotherapy and external beam radiotherapy in colon cancer xenografts

    International Nuclear Information System (INIS)

    Buras, R.R.; Wong, J.F.C.; Kuhn, J.A.; Beatty, B.G.; Williams, L.E.; Beatty, J.D.; Wanek, P.M.

    1993-01-01

    Radioimmunotherapy and external beam radiotherapy were compared in a nude mouse human colon cancer model. Radioimmunotherapy was delivered by intraperitoneal injection of 90 Y-labeled anticarcinoembryonic antigen monoclonal antibody (anti-CEA MAB). Single fraction external beam radiotherapy was delivered using a 60 Co teletherapy unit. Control groups received saline, unlabeled anit-CEA monoclonal antibody and labeled nonspecific monoclonal antibody. Tumor growth suppression was expressed as delay to reach 2g compared to saline controls. Unlabeled anti-CEA monoclonal antibody and labeled nonspecific monoclonal antibody had no effect. External beam radiotherapy of 300, 600, 1000 and 2000 cGy produced growth delays of 3, 12, 17, and 22 days, respectively. Radioimmunotherapy with 120 μCi, 175 μCi, and 225 μCi resulted in growth delays of 20, 34, and 36 days. Estimated absorbed tumor dose was 1750 cGy in the 120 μCi group. Similar comparisons were done with the more radioresistant WiDr human colon carcinoma cell line. External beam radiotherapy doses of 400, 800, 1200, and 1600 cGy resulted in growth delays of 6, 21, 36 and 48 days, respectively. Radioimmunotherapy of 120 μCi and 175 μCi resulted in growth delays of 9 and 19 days, respectively. The 120 μCi dose delivered an estimated absorbed tumor dose of 1080 cGy to WiDr tumors. In summary, for the radiosensitive LS174T line, radioimmunotherapy produced biologic effects that were comparable to a similar dose of single fraction external beam radiotherapy. For the more radioresistant WiDr tumor, radioimmunotherapy produced a biologic effect which was less than a similar dose of single fraction external beam radiotherapy. These studies suggest that a tumor's response to radioimmunotherapy relative to that of external beam radiotherapy is, in part, dependent on tumor radiosensitivity and repair capacity. 23 refs., 5 figs. 4 tabs

  11. tion using external beam radiation in gynaecological cancers

    African Journals Online (AJOL)

    Enrique

    tor was then adjusted to that distance using the graduated markings and was fixed with a fixation device to pre- vent it being pushed in by changes in the position of the legs. Using the pre- sent technique, after the lower extent of disease has been noted, an external leadwire marker is placed over the. ORIGINAL ARTICLE.

  12. TOPICAL REVIEW: Dose calculations for external photon beams in radiotherapy

    Science.gov (United States)

    Ahnesjö, Anders; Mania Aspradakis, Maria

    1999-11-01

    Dose calculation methods for photon beams are reviewed in the context of radiation therapy treatment planning. Following introductory summaries on photon beam characteristics and clinical requirements on dose calculations, calculation methods are described in order of increasing explicitness of particle transport. The simplest are dose ratio factorizations limited to point dose estimates useful for checking other more general, but also more complex, approaches. Some methods incorporate detailed modelling of scatter dose through differentiation of measured data combined with various integration techniques. State-of-the-art methods based on point or pencil kernels, which are derived through Monte Carlo simulations, to characterize secondary particle transport are presented in some detail. Explicit particle transport methods, such as Monte Carlo, are briefly summarized. The extensive literature on beam characterization and handling of treatment head scatter is reviewed in the context of providing phase space data for kernel based and/or direct Monte Carlo dose calculations. Finally, a brief overview of inverse methods for optimization and dose reconstruction is provided.

  13. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    . By adapting a bar geometry, the output power could be scaled even up to several tens of watts. Unfortunately, the high divergence which is a characteristic feature of the bar geometry could lead to a degradation of the overall beam quality of the laser bar. However, spectral beam combining is an effective...... solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm...

  14. The use of beam code in external radiotherapy

    International Nuclear Information System (INIS)

    Guillerminet, C.; Gschwind, R.; Makovicka, L.

    2003-01-01

    This code, in constant evolution, has several assets because it allows in one hand to better characterize the beams at the energy and angular level of accelerators at medical use; these data being accessible only by simulation and on the other hand to establish a three dimensional dose calculation fro any phantom. The limit factors are the calculation time, the size of voxels need important dimension tables for the data storage, and the compatibility between the code and the different images formats. (N.C.)

  15. A quality audit program for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, W.F.; Stovall, M. [Univ. of Texas, Houston, TX (United States)

    1993-12-31

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%.

  16. A quality audit program for external beam radiotherapy

    International Nuclear Information System (INIS)

    Hanson, W.F.; Stovall, M.

    1993-01-01

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%

  17. External beam monitoring of the Cyclone 30 cyclotron of IPEN-CNEN-SP

    International Nuclear Information System (INIS)

    Matsuda, Hylton

    2002-01-01

    Due to the increasing demand for cyclotron radioisotopes and the high cost of equipment and materials involved in the process, it becomes evident the importance of external beam monitoring of the cyclotron. In this way, the beam of the Cyclone 30 cyclotron of IPEN-CNEN/S P was characterized throughout the evaluation of its current intensity, profile (position, focus and geometry), alignment and homogeneity, by measuring currents, temperatures and pressures of irradiation systems. For this purpose, techniques and conventional devices, thermocouples and pressure sensors associated to electronic of instrumentation, and technology and flexibility of micro controllers allowed observing the beam behavior during irradiations in real time. The ion beam energy was also evaluated using activation analysis technique of monitor reactions in nat Cu. The beam monitoring systems have been contributing to prevent material damages and they have already been used in routine irradiations, bringing important advantages in the process of beam optimization of the Cyclone 30. (author)

  18. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Vincent W.C. [Department of Health Technology and Informatics, Hong Kong Polytechnic University, Kowloon, Hong Kong (Hong Kong); Yang Zhining; Zhang Wuzhe; Wu Lili [Cancer Hospital, Shantou University Medical College, Shantou (China); Lin Zhixiong, E-mail: zxlin5@yahoo.com [Cancer Hospital, Shantou University Medical College, Shantou (China)

    2012-07-01

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

  19. Quality assurance network in central Europe. External audit on output calibration for photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Izewska, J. [Radiotherapy Dept., Univ. Hospital Gasthuisberg, Leuven (Belgium); Novotny, J. [Radiotherapy Dept., Univ. Hospital Gasthuisberg, Leuven (Belgium); Gwiazdowska, B. [Medical Physics Dept., Cancer Centre, Warsaw (Poland); Kindlova, A. [Dept. of Radiotherapy and Oncology, Univ. Hospital Vinohrady, Prague (Czech Republic); Kontra, G. [National Inst. of Oncology, Budapest (Hungary); Dam, J. van [Radiotherapy Dept., Univ. Hospital Gasthuisberg, Leuven (Belgium); Dutreix, A. [Radiotherapy Dept., Univ. Hospital Gasthuisberg, Leuven (Belgium); Schueren, E. van der [Radiotherapy Dept., Univ. Hospital Gasthuisberg, Leuven (Belgium)

    1995-12-31

    The EROPAQ project for TLD monitoring of photon beams started in June 1994 with the set-up of the TLD system: calibration, reading and evaluation procedures. The acceptance level of {+-}3% was set for the TLD intercomparisons. The policy of the project was to check all beams in 47 participating radiotherapy centres and to recheck all the beams in those centres, where a deviation exceeding {+-}3% occurred in one or more of the beams. Out of 129 beams checked, 100 beams (78%) were found within the {+-}3% limit. Eleven beams show deviations larger than {+-}6%, and immediate corrective action was undertaken. Out of 47 centres checked, 22 did not participate in any external audit in a preceding 5 years. In these centres 68% (34/50) of the total number of {gamma} and X-ray beams checked but only 59% (20/34) of {gamma} beams were within the acceptance level, while in the 25 centres, which participated in an external audit before, these figures were 84% (66/79) and 88% (35/40) respectively. The sources of discrepancies were thoroughly investigated, discussed with the participants and the errors corrected. Poor results were in several cases associated with very old design of radiotherapy units and old dosimetry systems, equipped with inadequate ionization chambers. In several centres, an insufficient training of the physicists in clinical dosimetry was observed. Thanks to the corrective action, a great improvement of calibration of the beams was achieved. Standard deviation of the distribution of the results for all x and {gamma} beams checked decreased from SD = 7.4% at the first check to SD = 2.5% at the second check. (orig.).

  20. External beam radiotherapy combined with intraluminal brachytherapy in esophageal carcinoma

    International Nuclear Information System (INIS)

    Muijs, Christina T.; Beukema, Jannet C.; Mul, Veronique E.; Plukker, John Th.; Sijtsema, Nanna M.; Langendijk, Johannes A.

    2012-01-01

    Purpose: To assess the effectiveness of definitive radiation therapy in patients with potentially curable esophageal cancer and to evaluate the side-effects of this treatment. Methods and materials: Sixty-two patients with esophageal cancer, who were treated with definitive, curatively intended radiotherapy consisting of external radiotherapy (60 Gy in 30 fractions), preceded and followed by LDR or HDR intraluminal brachy (12 Gy in 2 fractions) were retrospectively analyzed. Results: Recurrences were reported in 38 patients (61%), of which 25 (64%) failed locally first. The overall survival rates at 1, 2 and 5 years were 57%, 34% and 11%, respectively. The median overall survival was 15 months. No prognostic factors could be identified. Most frequently reported treatment related toxicities were esophagitis, ulcerations, (11%) and strictures (16%). In 10 patients (16%) severe toxicities, were reported including grade III ulceration (2 cases), stricture (1 case), radiation pneumonitis (1 case), perforation (1 case), esophageal-pleural-tracheal fistula (1 case), and acute esophageal bleeding (4 cases). A history of gastrectomy was significantly associated with the development of severe toxicity. Conclusion: Curatively intended radiotherapy alone can be offered to esophageal cancer patients, even when surgery and/or chemotherapy are not feasible. However, we observed severe toxicity in a substantial part of the patients. Given the relatively high rate of severe complications and the uncertainties regarding dose escalation, the addition of brachytherapy, with consequently high surface doses, should be limited to well-selected patients.

  1. Normal tissue tolerance to external beam radiation therapy: Esophagus

    International Nuclear Information System (INIS)

    Bera, G.; Pointreau, Y.; Denis, F.; Dupuis, O.; Orain, I.; Crehange, G.

    2010-01-01

    The esophagus is a musculo-membranous tube through which food passes from the pharynx to the stomach. Due to its anatomical location, it can be exposed to ionizing radiation in many external radiotherapy indications. Radiation-induced esophageal mucositis is clinically revealed by dysphagia and odynophagia, and usually begins 3 to 4 weeks after the start of radiation treatment. With the rise of multimodality treatments (e.g., concurrent chemoradiotherapy, dose escalation and accelerated fractionation schemes), esophageal toxicity has become a significant dose-limiting issue. Understanding the predictive factors of esophageal injury may improve the optimal delivery of treatment plans. It may help to minimize the risks, hence increasing the therapeutic ratio. Based on a large literature review, our study describes both early and late radiation-induced esophageal injuries and highlights some of the predictive factors for cervical and thoracic esophagus toxicity. These clinical and dosimetric parameters are numerous but none is consensual. The large number of dosimetric parameters strengthens the need of an overall analysis of the dose/volume histograms. The data provided is insufficient to recommend their routine use to prevent radiation-induced esophagitis. Defining guidelines for the tolerance of the esophagus to ionizing radiation remains essential for a safe and efficient treatment. (authors)

  2. Reinforced concrete T-beams externally prestressed with unbonded carbon fiber-reinforced polymer tendons

    DEFF Research Database (Denmark)

    Bennitz, Anders; Nilimaa, Jonny; Täljsten, Björn

    2012-01-01

    This study describes a series of experiments examining the behavior of seven beams prestressed with unbonded external carbon fiberreinforced polymer (CFRP) tendons anchored using a newly developed anchorage and post-tensioning system. The effects of varying the initial tendon depth, prestressing...... force, and the presence of a deviator were investigated. The results were compared to those observed with analogous beams prestressed with steel tendons, common beam theory, and predictions made using an analytical model adapted from the literature. It was found that steel and CFRP tendons had very...

  3. Adjuvant chemoradiation after laparoscopically assisted radical vaginal hysterectomy (LARVH) in patients with cervical cancer. Oncologic outcome and morbidity

    International Nuclear Information System (INIS)

    Gruen, Arne; Musik, Thabea; Stromberger, Carmen; Budach, Volker; Marnitz, Simone; Koehler, Christhardt; Schneider, Achim; Fueller, Juergen; Wendt, Thomas

    2011-01-01

    Compared to laparotomic surgery, laparoscopically assisted radical vaginal hysterectomy (LARVH) offers decreased blood loss during surgery and faster convalescence of the patient postoperatively, while at the same time delivering similar oncologic results. However, there is no data on outcome and toxicity of LARVH followed by (chemo)radiation. A total of 55 patients (range 28-78 years) with cervical cancer on FIGO stages IB1-IIIA (Tables 1 and 2) with risk factors were submitted to either external beam radiotherapy alone [EBRT, n = 8 (14%), including paraaortic irradiation, n = 4 (2.2%); EBRT and brachytherapy (BT), n = 33 (60%); BT alone, n = 14 (25.5%)] or chemoradiation after LARVH. At a median follow-up of 4.4 years, the 5-year disease-free survival (DFS) was 81.8% with 84.5% overall survival (OS). Acute grade 3 side effects were seen in 4 patients. These were mainly gastrointestinal (GI) and genitourinary (GU) symptoms. Grade 4 side effects were not observed. With similar oncologic outcome data and mostly mild side effects, LARVH followed by (chemo)radiation is a valid alternative in the treatment of cervical cancer patients. (orig.)

  4. Flexural Behavior of RC Members Using Externally Bonded Aluminum-Glass Fiber Composite Beams

    Directory of Open Access Journals (Sweden)

    Ki-Nam Hong

    2014-03-01

    Full Text Available This study concerns improvement of flexural stiffness/strength of concrete members reinforced with externally bonded, aluminum-glass fiber composite (AGC beams. An experimental program, consisting of seven reinforced concrete slabs and seven reinforced concrete beams strengthened in flexure with AGC beams, was initiated under four-point bending in order to evaluate three parameters: the cross-sectional shape of the AGC beam, the glass fiber fabric array, and the installation of fasteners. The load-deflection response, strain distribution along the longitudinal axis of the beam, and associated failure modes of the tested specimens were recorded. It was observed that the AGC beam led to an increase of the initial cracking load, yielding load of the tension steels and peak load. On the other hand, the ductility of some specimens strengthened was reduced by more than 50%. The A-type AGC beam was more efficient in slab specimens than in beam specimens and the B-type was more suitable for beam specimens than for slabs.

  5. The Evolution of External Beam Radiation Therapy (EBRT) from a Technological Perspective.

    Science.gov (United States)

    Detorie, Nicholas

    2008-03-01

    Since the discovery of x-rays by Roentgen in 1895 ionizing radiations have been used as a treatment for cancer. Such treatments have been based on either implantation of radioactive materials at the site of disease or by aiming external radiation beams at the diseased site. This later method is referred to as teletherapy because the beams originate from a location outside of the body distant from the disease site itself. A brief review of the basic radiation biology will be given to illustrate the rationale for therapeutic use of ionizing radiations and the effects of beam energy and beam type- particulate or photon. The remainder of the presentation will focus on the technological teletherapy developments supported by the required physical properties of the beams and their associated characteristics that make them suitable for patient treatments. Chronological highlights will include the following sources or devices: superficial x-rays, orthovaltage x-rays, megavoltage x-rays and Cobalt 60 photons, electron beams, neutron beams, negative pi mesons, protons, and heavy ions. The presentation will illustrate how the physical beam properties have been incorporated into modern radiation treatment devices, many of which are equipped with radiation imaging capability. Such devices include: linacs equipped with multileaf collimators for beam shaping and intensity modulation, the Gamma Knife for precise and accurate irradiation of brain tumors or arterial-venous malformations (AVM), the robotic arm based Cyber Knife, and the Helical Tomotherapy unit.

  6. External beam radiotherapy for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Sagerman, R.H.; Chun, H.C.; King, G.A.; Chung, C.T.; Dalal, P.S.

    1989-01-01

    Five hundred nineteen patients with prostate cancer were seen in the Radiation Oncology Division of the State University of New York (SUNY) Health Science Center, Syracuse, New York, between 1969 and 1981. The results for the 239 patients treated with radical intent are reported here. All patients received 60 to 70 Gy to the prostate with megavoltage beam irradiation; 142 with a small field (10 X 10 cm) 360 degrees rotational technique for Stage A, B, or C disease and 69 with a four-field pelvic brick technique (followed by a boost to the prostate) for Stage A through C and D1 disease. Twenty-eight patients were treated postoperatively for residual disease after radical prostatectomy or for recurrent tumor. The minimum follow-up time was 5 years. Actuarial 5-year and 7-year survival rates for Stage A (n = 34), B (n = 100), C (n = 63), and D1 (n = 14) were 91% and 76%, 86% and 75%, 67% and 40%, and 46% and 36%, respectively. The corresponding 5-year and 7-year relapse-free survival rates were 72% and 65%, 77% and 60%, 46% and 28%, and 38% and 25%. The local tumor control rates at 5 years were 91%, 85%, 77%, and 62% for Stage A, B, C, and D1, respectively. In our experience, there was no significant difference in relapse-free survival rates for patients who underwent transurethral resection (TURP) versus those who did not (67% versus 78% for Stage B [P greater than 0.25] and 38% versus 47% for Stage C [P greater than 0.25], respectively). Also there was no significant difference in relapse-free survival rates between large and small field techniques (64% versus 77% for Stage B [P greater than 0.25] and 56% versus 41% for Stage C [P greater than 0.25], respectively). The 5-year and 7-year actuarial survival rates were 90% and 71%, respectively, for the 15 patients with residual tumor and 58% and 33%, respectively, for the 13 patients treated for postprostatectomy recurrence

  7. Reinforced concrete T-beams externally prestressed with unbonded carbon fiber-reinforced polymer tendons

    DEFF Research Database (Denmark)

    Bennitz, Anders; Nilimaa, Jonny; Täljsten, Björn

    2012-01-01

    This study describes a series of experiments examining the behavior of seven beams prestressed with unbonded external carbon fiberreinforced polymer (CFRP) tendons anchored using a newly developed anchorage and post-tensioning system. The effects of varying the initial tendon depth, prestressing...

  8. Implementation of a system for external audits beam radiation therapy in terms of reference no

    International Nuclear Information System (INIS)

    Alonso Samper, Jose Luis; Dominguez, Lourdes; Alert Silva, Jose; Alfonso Laguardia, Rodolfo; Larrinaga Cortina, Eduardo; Garcia Yip, Fernando; Rodriguez Machado, Jorge; Morales Lopez, Jorge Luis; Silvestre Patallo, Ileana

    2009-01-01

    This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made.This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made. Centers were audited with external beam high-energy Co-60, 6 MV and 15 MV and were considered 4 treatment planning systems (TPS): AMEPLAN, Theraplan Plus, Precise Plan and MIRS to calculate doses prescribed in each test case. All measurements were acquired by the audit team using the anthropomorphic phantom CIRS, Semiflex chamber PTW 31010 and PTW electrometer STATES. The implementation and development of the external audits of beams radiotherapy in terms of 'no reference' has brought an improvement in both clinical aspects of treatment and the radiation safety and the quality control, has given us greater confidence and for this reason we believe has become essential. (Author)

  9. Shear Strengthening of RC Deep Beam Using Externally Bonded GFRP Fabrics

    Science.gov (United States)

    Kumari, A.; Patel, S. S.; Nayak, A. N.

    2018-02-01

    This work presents the experimental investigation of RC deep beams wrapped with externally bonded Glass Fibre Reinforced Polymer (GFRP) fabrics in order to study the Load versus deflection behavior, cracking pattern, failure modes and ultimate shear strength. A total number of five deep beams have been casted, which is designed with conventional steel reinforcement as per IS: 456 (Indian standard plain and reinforced concrete—code for practice, Bureau of Indian Standards, New Delhi, 2000). The spans to depth ratio for all RC deep beams have been kept less than 2 as per the above specification. Out of five RC deep beams, one without retrofitting serves as a reference beam and the rest four have been wrapped with GFRP fabrics in multiple layers and tested with two point loading condition. The first cracking load, ultimate load and the shear contribution of GFRP to the deep beams have been observed. A critical discussion is made with respect to the enhancement of the strength, behaviour and performance of retrofitted deep beams in comparison to the deep beam without GFRP in order to explore the potential use of GFRP for strengthening the RC deep beams. Test results have demonstrated that the deep beams retrofitted with GFRP shows a slower development of the diagonal cracks and improves shear carrying capacity of the RC deep beam. A comparative study of the experimental results with the theoretical ones predicted by various researchers available in the literatures has also been presented. It is observed that the ultimate load of the beams retrofitted with GFRP fabrics increases with increase of number of GFRP layers up to a specific number of layers, i.e. 3 layers, beyond which it decreases.

  10. External beam radiation for retinoblastoma: Results, patterns of failure, and a proposal for treatment guidelines

    International Nuclear Information System (INIS)

    Hernandez, J. Carlos; Brady, Luther W.; Shields, Jerry A.; Shields, Carol L.; Potter, Patrick de; Karlsson, Ulf L.; Markoe, Arnold M.; Amendola, Beatriz E.; Singh, Arun

    1996-01-01

    Purpose: To analyze treatment results and patterns of failure following external beam radiation for retinoblastoma and propose treatment guidelines according to specific clinical variables. Methods and Materials: We analyzed 27 patients (34 eyes) with retinoblastoma who received external beam radiation as initial treatment at Hahnemann University Hospital from October 1980 to December 1991 and have been followed for at least 1 year. Of the 34 eyes, 14 were Groups I-II (Reese-Ellsworth classification), 7 were Group III, and 13 were Groups IV-V. Doses ranged from 34.5-49.5 Gy (mean 44.3 Gy, median 45 Gy) in 1.5-2.0 Gy fractions generally delivered through anterior and lateral wedged pair fields. Results: At a mean follow up of 35.2 months (range 12-93 months), local tumor control was obtained in 44% (15 out of 34) of eyes with external beam radiation alone. Salvage therapy (plaque brachytherapy, cryotherapy, and/or photocoagulation) controlled an additional 10 eyes (29.5%), so that overall ocular survival has been 73.5%. Local tumor control with external beam radiotherapy alone was obtained in 78.5% (11 out of 14) of eyes in Groups I-II, but in only 20% (4 out of 20) of eyes in Groups III-V. A total of 67 existing tumors were identified prior to treatment in the 34 treated eyes and local control with external beam radiation alone was obtained in 87% (46 out of 53) of tumors measuring 15 mm or less and in 50% (7 out of 14) of tumors measuring more than 15 mm. When analyzing patterns of failure in the 19 eyes that relapsed, a total of 28 failure sites were identified and consisted of progression of vitreous seeds in seven instances (25% of failure sites) recurrences from previously existing tumors in 10 instances (36% of failure sites) and development of new tumors in previously uninvolved retina in 11 instances (39% of failure sites). Conclusions: 1) We find that external beam radiation to a dose of 45 Gy in fractions of 1.5 to 2.0 Gy provides adequate tumor control

  11. Chaotic oscillations in electron beam with virtual cathode in external magnetic field

    Science.gov (United States)

    Hramov, A. E.; Koronovskiy, A. A.; Kurkin, S. A.; Rempen, I. S.

    2011-11-01

    This article presents the results of a numerical study of external magnetic field influence on the conditions and mechanisms of virtual cathode (VC) formation in a relativistic electron beam. It also considers other related issues, e.g. peculiarities of nonlinear dynamics of electron beam with VC under changed external magnetic field, different mechanisms of VC oscillation chaotisation leading to complication of vircator system dynamics and appearance of multi-frequency VC oscillations. General systemic mechanism of VC oscillation chaotisation has been identified which is connected with formation of electronic patterns in electron beam whose interaction in the common field of spatial charge determines appearance of additional inner feedback. Transition from chaotic to periodical oscillation regime is found to be connected with destroying the mechanism of secondary electronic structures (electron bunches) formation. Besides, the influence of extent of screening of electron gun from magnetic field is discussed.

  12. Target volume delineation in external beam partial breast irradiation: less inter-observer variation with preoperative- compared to postoperative delineation

    NARCIS (Netherlands)

    Leij, F. van der; Elkhuizen, P.H.M.; Janssen, T.M.; Poortmans, P.M.P.; Sangen, M. van der; Scholten, A.N.; Vliet-Vroegindeweij, C. van; Boersma, L.J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of

  13. Influence of external beam technique and brachytherapy quality assurance on the side effects in the combined external beam- and brachytherapy treatment of local advanced prostate cancer

    International Nuclear Information System (INIS)

    Kovacs, G.; Galalae, R.; Wirth, B.; Bertermann, H.; Wilhelm, R.; Kohr, P.; Kimmig, B.

    1996-01-01

    Transrectal ultrasound(TRUS) guided HDR implantation of the prostate has been established at the Kiel University by Bertermann and Brix in 1986 and there are to date 179 (T1b-T3 No Mo) patients treated in a combined modality. The dose for the implant was 2x 15 Gy on the capsule of the prostate in 14-20 days. For local and regional lymph nodes 20 Gy external beam therapy (AP-PA pelvic portals), 20 Gy with an individual transmission block (100% for subclinical disease, 70% and 50% according to the implant dosimetry for the prostate) and 10 Gy small volume irradiation for the prostate was applied, conventional fractioned. Total dose after the therapy 70 Gy for the prostate and 50 Gy for the subclinical disease in 6-7 weeks. As a quality control method we use since 1991 in vivo dosimetry on the medial rectum wall as well as in the prostatic part of the urethra. Regular follow-up 3-118 months after therapy (median 55) with PSA, digital rectal examination, control TRUS with volumetry (after one year with biopsy) and bone scan. There were no major early side effects within the first three months. Proctitis till 1991 with a duration up to 12 months 49%, prolonging more than one year in 23 %, (total proctitis 72.6%). Dysuria in up to 12 months 30 %, long lasting 30% (total number of dysuria 60 %). Erectile dysfunction in 56 %. Because of the number of the side effects 1991 we changed the external beam technique: instead of the biaxial arch therapy the AP-PA portals, and reduced irradiated volume (from 6480 cm 3 to 5040 cm 3 ). We introduced instead of the small volume arch therapy for 10 Gy external boost the box-technique with shielding the back part of the rectum and the upper part of the bladder resulting additional volume reduction. Through the 15 Gy HDR brachytherapy dose on the prostate capsule there are up to 8 Gy on the medial rectal wall, measured by in vivo dosimetry. This dose could not be responsible for the high number of side effects (see gynecological

  14. Development of an external beam nuclear microprobe on the Aglae facility of the Louvre museum

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. E-mail: dran@culture.fr; Ioannidou, E.; Moignard, B.; Pichon, L.; Salomon, J

    2000-03-01

    The external beam line of our facility has been recently equipped with the focusing system previously mounted on a classical nuclear microprobe. When using a 0.1 {mu}m thick Si{sub 3}N{sub 4} foil for the exit window and flowing helium on the sample under analysis, a beam spot as small as 10 {mu}m is attainable at a distance of 3 mm from the window. Elemental micromapping is performed by mechanical scanning. An electronic device has been designed which allows XY scanning by moving the sample under the beam by steps down to 0.1 {mu}m. Beam monitoring is carried out by means of the weak X-ray signal emitted by the exit foil and detected by a specially designed Si(Li) detector cooled by Peltier effect. The characteristics of external beams of protons and alpha particles are evaluated by means of resonance scanning and elemental mapping of a grid. An example of application is presented, dealing with elemental micro-mapping of inclusions in gemstones.

  15. The target volume concept at the recording of external beam radiotherapy

    International Nuclear Information System (INIS)

    Quast, U.; Glaeser, L.

    1981-01-01

    With the aim of complete, exact and reproducible manual recording and documentation of external beam radiotherapy a concept is proposed providing treatment planning and recording related to space and time for target volumes of different order corresponding to Ist, IInd or IIIrd part of treatment course, regarding all dose limiting organs at risk. The record consists of the dosage plan for medical treatment planning, the treatment plan for physical dose distribution planning and the treatment record of absorbed doses delivered as well as a checklist for patient and machine set-up, and labels for intended actions during treatment development. A clear arrangement of the record form in logical order was found, demanding exact specification of target(s) and beam(s) and their relation in space and time; asking for verbal and graphical description of target volumes, organs at risk, patient positioning, beam portals and dose reference points in terms of patients' anatomy; emphasizing the most important medical data by marked areas and leaving enough empty space for additional data, remarks or comments. During several years of clinical use these record forms proved to be suitable for all cases of external beam therapy, for complex situations of target volumes and treatment-scheduling, for all treatment techniques and radiation qualities and for all ways of physical treatment planning. They can be extended to automatic treatment verification, monitoring and recording as well as to the application of in-vivo-measurements of absorbed doses. (orig.) [de

  16. Local control rate and prognosis after sequential chemoradiation for small cell carcinoma of the bladder

    International Nuclear Information System (INIS)

    Meijer, Richard P.; Meinhardt, Wim; Poel, Henk G. van der; Rhijn, Bas W. van; Kerst, J. Martijn; Pos, Floris J.; Horenblas, Simon; Bex, Axel

    2013-01-01

    The objectives of this study were to assess the long-term outcome and the risk for local recurrence of patients with small cell carcinoma of the bladder (SCCB) treated with neoadjuvant chemotherapy followed by external beam radiotherapy (sequential chemoradiation). All consecutive patients with primary small cell carcinoma of the bladder (n=66), treated in our institution between 1993 and 2011 were retrospectively evaluated from an institutional database. Only patients with limited disease (Tx-4N0-1M0) small cell carcinoma of the bladder treated with sequential chemoradiation (n=27) were included in this study. Recurrence rates, overall survival and cancer-specific survival were analyzed using the Kaplan-Meier method. Median time to recurrence was 20 months, median overall survival 26 months, 5-year overall survival 22.2%, median cancer-specific survival 47 months and 5-year cancer-specific survival 39.6%. For complete responders after neoadjuvant chemotherapy (n=19), median cancer-specific survival was 52 months with a 5-year cancer-specific survival 45.9% versus a median cancer-specific survival of 22 months and 5-year cancer-specific survival 0.0% for incomplete responders (n=8; P=0.034). Eight patients (29.6%) underwent transurethral resections (TUR-BT) for local recurrences in the bladder. At the end of follow up, four patients had undergone cystectomy for recurrence of disease resulting in a bladder-preservation rate of 85.2%. Median time to local recurrence was 29 months and median time to distant recurrence was 10 months. Sequential chemoradiation for limited disease small cell carcinoma of the bladder results in a reasonable outcome with a high bladder preservation rate. Response to neoadjuvant chemotherapy represents a significant prognostic factor in this patient population. (author)

  17. An assessment of effective dose to staff in external beam radiotherapy

    International Nuclear Information System (INIS)

    Rawlings, D.J.; Nicholson, L.

    1997-01-01

    Radiation safety in external beam radiotherapy is governed by national legislation. Annual doses recorded by radiographers and others associated with external beam radiotherapy are typically much lower than the relevant dose limit. However, it is possible that larger doses might be received as a result of an accidental irradiation. In the event of a significant exposure resulting in a dose at or near a relevant dose limit, an accurate conversion has to be made from the dose meter reading to the limiting quantity. A method was devised to demonstrate ratios of effective dose to personal dose equivalent which might be anticipated in the even of an individual other than the patient being irradiated within a radiotherapy treatment room consisting of a linear accelerator. The variation of ratios obtained under different conditions is discussed. (author)

  18. External beam radiotherapy for palliation of pain from metastatic carcinoma of the prostate

    International Nuclear Information System (INIS)

    Benson, R.C. Jr.; Hasan, S.M.; Jones, A.G.; Schlise, S.

    1982-01-01

    Radiotherapy often is used for palliation of bone pain from metastatic cancer of the prostate but an objective evaluation of its efficacy in a large series of patients is unavailable. We report the results of external beam irradiation in 62 patients who had bone pain secondary to stage D carcinoma of the prostate. The variables used to judge pain before and after radiotherapy included subjective evaluation of pain, status of activity and quantitation of analgesic use. Complete relief of pain was achieved in 26 patients (42 per cent), partial relief in 22 (35 per cent) and no relief in 14 (23 per cent). On the basis of our experience external beam irradiation is useful palliative therapy for pain from metastatic cancer of the prostate

  19. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    International Nuclear Information System (INIS)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V.

    2009-01-01

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  20. PIXE/PIGE characterisation of emeralds using an external micro-beam

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.; Poirot, J.-P.; Querre, G.; Salomon, J.; Zwaan, J.C.

    2000-01-01

    A large collection of emeralds of various occurrences has been analysed by PIXE/PIGE in view to establish a compositional database. Major elements (Be, Si, Al) and trace elements (Li, F, Na, Mg, Ca, Rb, Cs and transition metals) are determined using an external 3 MeV proton micro-beam. Elemental micro-mapping permits to select the useful provenance tracers. This database was applied to infer the origin of several ancient emeralds set on historical jewels

  1. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Antonio C. Westphalen

    2009-04-01

    Full Text Available PURPOSE: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. MATERIAL AND METHODS: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher’s exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25 and those imaged more than 3 years after therapy (n = 34. Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. RESULTS: Thirty-four of 59 patients (58% had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59 for reader 1 and 71% for reader 2 (42/59. For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2. CONCLUSION: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy.

  2. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V. [University of California San Francisco, San Francisco, CA (United States). Dept. of Radiology. Abdominal Imaging Section], e-mail: antonio.westphalen@radiology.ucsf.edu

    2009-01-15

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  3. MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

    International Nuclear Information System (INIS)

    Sutlief, S.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  4. 3D FE Analysis of RC Beams Externally Strengthened with SRG/SRP Systems

    Directory of Open Access Journals (Sweden)

    Francesco Bencardino

    2016-05-01

    Full Text Available The purpose of this study is to evaluate, through a nonlinear Finite Element (FE analysis, the structural behavior of Reinforced Concrete (RC beams externally strengthened by using Steel Reinforced Grout (SRG and Steel Reinforced Polymer (SRP systems. The parameters taken into account were the external strengthening configuration, with or without U-wrap end anchorages, as well as the strengthening materials. The numerical simulations were carried out by using a three-dimensional (3D FE model. The linear and nonlinear behavior of all materials was modeled by appropriate constitutive laws and the connection between concrete substrate and external reinforcing layer was simulated by means of cohesive surfaces with appropriate bond-slip laws. In order to overcome convergence difficulties, to simulate the quasi-static response of the strengthened RC beams, a dynamic approach was adopted. The numerical results in terms of load-displacement curves, failure modes, and load and strain values at critical stages were validated against some experimental data. As a result, the proposed 3D FE model can be used to predict the structural behavior up to ultimate stage of similar strengthened beams without carrying out experimental tests.

  5. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    Science.gov (United States)

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  6. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    International Nuclear Information System (INIS)

    Alvarez R, J T; Tovar M, V M

    2008-01-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D W = 2 Gy·c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D W for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals

  7. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    Science.gov (United States)

    Álvarez R., J. T.; Tovar M., V. M.

    2008-08-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described—for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 °C plus 24 hrs 80 °C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal DW = 2 Gy ṡ c ) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water DW for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

  8. ERDA with an external helium ion micro-beam: Advantages and potential applications

    International Nuclear Information System (INIS)

    Calligaro, T.; Castaing, J.; Dran, J.-C.; Moignard, B.; Pivin, J.-C.; Prasad, G.V.R.; Salomon, J.; Walter, P.

    2001-01-01

    Preliminary ERDA experiments at atmospheric pressure have been performed with our external microprobe set-up currently used for the analysis of museum objects by PIXE, RBS and NRA. The objective was to check the feasibility of hydrogen (and deuterium) profiling with an external beam of 3-MeV helium ions. The standard scattering geometry (incident beam at 15 deg. with respect to sample surface and emerging protons or deuterons at 15 deg. in the forward direction) was kept, but the thin foil absorber was replaced by helium gas filling the space between the beam spot and the detector over a distance of about 84 mm. Several standards prepared by ion implantation, with well known H or D depth profiles, were first analysed, which indicated that the analytical capability was as good as under vacuum. A striking feature is the much lower surface peak than under vacuum, a fact that enhances the sensitivity for H analysis near the surface. The same type of measurement was then performed on different materials to show the usefulness of the technique. As a first example, we have checked that the incorporation of H or D into sapphire crystals during mechanical polishing is below the detection limit. Another example is the measurement of the H content in emeralds which can be used as an additional compositional criterion for determining the provenance of emeralds set in museum jewels. The advantages and limitations of our set-up are discussed and several possible applications in the field of cultural heritage are described

  9. Proton external beam in the TANDAR Accelerator; Haz externo de protones en el acelerador TANDAR

    Energy Technology Data Exchange (ETDEWEB)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M. [Departamento de Fisica, Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, C.P. 1650 San Martin, Buenos Aires (Argentina)

    1998-12-31

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm{sup 2} approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  10. Kilovoltage Rotational External Beam Radiotherapy on a Breast Computed Tomography Platform: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Prionas, Nicolas D.; McKenney, Sarah E. [Department of Radiology, University of California, Davis, Medical Center, Sacramento, California (United States); Stern, Robin L. [Department of Radiation Oncology, University of California, Davis, Medical Center, Sacramento, California (United States); Boone, John M., E-mail: jmboone@ucdavis.edu [Department of Radiology, University of California, Davis, Medical Center, Sacramento, California (United States)

    2012-10-01

    Purpose: To demonstrate the feasibility of a dedicated breast computed tomography (bCT) platform to deliver rotational kilovoltage (kV) external beam radiotherapy (RT) for partial breast irradiation, whole breast irradiation, and dose painting. Methods and Materials: Rotational kV-external beam RT using the geometry of a prototype bCT platform was evaluated using a Monte Carlo simulator. A point source emitting 178 keV photons (approximating a 320-kVp spectrum with 4-mm copper filtration) was rotated around a 14-cm voxelized polyethylene disk (0.1 cm tall) or cylinder (9 cm tall) to simulate primary and primary plus scattered photon interactions, respectively. Simulations were also performed using voxelized bCT patient images. Beam collimation was varied in the x-y plane (1-14 cm) and in the z-direction (0.1-10 cm). Dose painting for multiple foci, line, and ring distributions was demonstrated using multiple rotations with varying beam collimation. Simulations using the scanner's native hardware (120 kVp filtered by 0.2-mm copper) were validated experimentally. Results: As the x-y collimator was narrowed, the two-dimensional dose profiles shifted from a cupped profile with a high edge dose to an increasingly peaked central dose distribution with a sharp dose falloff. Using a 1-cm beam, the cylinder edge dose was <7% of the dose deposition at the cylinder center. Simulations using 120-kVp X-rays showed distributions similar to the experimental measurements. A homogeneous dose distribution (<2.5% dose fluctuation) with a 20% decrease in dose deposition at the cylinder edge (i.e., skin sparing) was demonstrated by weighted summation of four dose profiles using different collimation widths. Simulations using patient bCT images demonstrated the potential for treatment planning and image-guided RT. Conclusions: Rotational kV-external beam RT for partial breast irradiation, dose painting, and whole breast irradiation with skin sparing is feasible on a bCT platform

  11. Chemoradiation of unresectable pancreatic carcinoma: impact of pretreatment hemoglobin level on patterns of failure

    Energy Technology Data Exchange (ETDEWEB)

    Morganti, A.G.; Macchia, G. [Dept. of Radiation Therapy, Univ. Cattolica del S. Cuore, Campobasso (Italy); Forni, F. [Dept. of Biochemistry and Clinical Biochemistry, Policlinico A. Gemelli, Univ. Cattolica del S. Cuore, Rome (Italy); Valentini, V.; Smaniotto, D.; Trodella, L.; Balducci, M.; Cellini, N. [Dept. of Radiation Therapy, Policlinico A. Gemelli, Univ. Cattolica del S. Cuore, Rome (Italy)

    2003-02-01

    Aim: To evaluate, in patients with locally advanced pancreatic carcinoma undergoing concomitant chemoradiation, the impact of pretreatment hemoglobin (Hb) concentration on the outcome in terms of clinical response, local control, metastasis-free survival, disease-free survival, and overall survival. Patients and Methods: 30 patients undergoing concomitant chemoradiation (5-fluorouracil [5-FU], 1,000 mg/m{sup 2}/day, continuous i.v. infusion days 1-4 of radiotherapy) and external beam radiotherapy (50.4-59.4 Gy) were divided into two groups based on pretreatment median Hb value (11.5 g/dl). The potential prognostic factors examined besides Hb concentration were: tumor site (head vs body-tail), sex (female vs male), cN (cN0 vs cN1), dose of external beam radiotherapy (50.4 Gy vs 59.4 Gy), presence of jaundice at diagnosis (yes vs no), weight loss at diagnosis ({>=} 5 kg vs < 5 kg), epigastric-lumbar pain at diagnosis (yes vs no), maximum tumor diameter (< 40 mm vs {>=} 40 mm). Results: Pretreatment Hb ranged between 9.6 and 15.0 g/dl. No statistically significant differences were observed as for clinical response and local control between patients with an Hb {<=} 11.5 g/dl and those with an Hb > 11.5 g/dl. Metastasis-free survival was 5.1 months in patients with an Hb {<=} 11.5 g/dl and 10.7 months in patients with an Hb > 11.5 g/dl (p = 0.010). Median actuarial disease-free survival was 5.1 and 10.2 months in patients with an Hb {<=} 11.5 and > 11.5 g/dl, respectively (p = 0.026). Median actuarial overall survival was 7.5 and 10.3 months in patients with an Hb {<=} 11.5 and > 11.5 g/dl, respectively (p = 0.039). On multivariate analysis, Hb concentration at diagnosis was the only factor prognostically correlated with metastasis-free survival (p = 0.026), disease-free survival (p = 0.032), and overall survival (p = 0.048). Conclusion: In a group of patients with locally advanced pancreatic carcinoma treated with chemoradiation, a significant correlation was observed

  12. Treatment of cancer of the pancreas by precision high dose (PHD) external photon beam and intraoperative electron beam therapy (IOEBT)

    International Nuclear Information System (INIS)

    Dobelbower, R.R. Jr.; Howard, J.M.; Bagne, F.R.; Eltaki, A.; Merrick, H.W. III

    1989-01-01

    Twenty-five patients with a diagnosis of unresectable adenocarcinoma of the pancreas were explored in the Clement O. Miniger (COMROC) IOEBT operating amphitheater at the Medical College of Ohio. Seventeen were treated with IOEBT (20-30 Gy, 15 or 18 meV electrons) PHD external beam radiation therapy (40-60 Gy, 1.8 Gy per fraction) plus appropriate operative biliary and gastrointestinal bypass procedures. No intraoperative complications were observed. Two patients died of causes that may have been treatment-related. Two patients developed abdominocutaneous fistulae. Pain was ameliorated in eleven of twelve patients. Jaundice was relieved in all patients. Four of ten patients with weight loss showed a reversal of that trend. Patient survival was not significantly different from that of patients treated with high-dose precision therapy alone

  13. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  14. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  15. External Beam Boost for Cancer of the Cervix Uteri When Intracavitary Therapy Cannot Be Performed

    International Nuclear Information System (INIS)

    Barraclough, Lisa Helen; Swindell, Ric; Livsey, Jacqueline E.; Hunter, Robin D.; Davidson, Susan E.

    2008-01-01

    Purpose: To assess the outcome of patients treated with radical radiotherapy for cervical cancer who received an external beam boost, in place of intracavitary brachytherapy (ICT), after irradiation to the whole pelvis. Methods and Materials: Case notes were reviewed for all patients treated in this way in a single center between 1996 and 2004. Patient and tumor details, the reasons why ICT was not possible, and treatment outcome were documented. Results: Forty-four patients were identified. The mean age was 56.4 years (range, 26-88 years). Clinical International Federation of Gynecology and Obstetrics or radiologic stage for Stages I, II, III, and IV, respectively, was 16%, 48%, 27%, and 7%. A total radiation dose of 54-70 Gy was given (75% received ≥60 Gy). Reasons for ICT not being performed were technical limitations in 73%, comorbidity or isolation limitations in 23%, and patient choice in 4%. The median follow-up was 2.3 years. Recurrent disease was seen in 48%, with a median time to recurrence of 2.3 years. Central recurrence was seen in 16 of the 21 patients with recurrent disease. The 5-year overall survival rate was 49.3%. The 3-year cancer-specific survival rate by stage was 100%, 70%, and 42% for Stages I, II, and III, respectively. Late Grades 1 and 2 bowel, bladder, and vaginal toxicity were seen in 41%. Late Grade 3 toxicity was seen in 2%. Conclusion: An external beam boost is a reasonable option after external beam radiotherapy to the pelvis when it is not possible to perform ICT

  16. Accelerated partial breast irradiation with external beam radiotherapy. First results of the German phase 2 trial

    International Nuclear Information System (INIS)

    Ott, Oliver J.; Strnad, Vratislav; Stillkrieg, Wilhelm; Fietkau, Rainer; Uter, Wolfgang; Beckmann, Matthias W.

    2017-01-01

    To evaluate the feasibility and efficacy of external beam three-dimensional (3D) conformal accelerated partial breast irradiation (APBI) for selected patients with early breast cancer. Between 2011 and 2016, 72 patients were recruited for this prospective phase 2 trial. Patients were eligible for APBI if they had histologically confirmed breast cancer or pure ductal carcinoma in situ (DCIS), a tumor diameter ≤3 cm, clear resection margins ≥2 mm, no axillary lymph node involvement, no distant metastases, tumor bed clips, and were aged ≥50 years. Patients were excluded if mammography showed a multicentric invasive growth pattern, or if they had residual diffuse microcalcifications postoperatively, an extensive intraductal component, or vessel invasion. Patients received 3D conformal external beam APBI with a total dose of 38 Gy in 10 fractions in 1-2 weeks. The trial had been registered at the German Clinical Trials Register, DRKS-ID: DRKS00004417. Median follow-up was 25.5 months (range 1-61 months). Local control was maintained in 71 of 72 patients. The 3-year local recurrence rate was 2.1% (95% confidence interval, CI: 0-6.1%). Early toxicity (grade 1 radiodermatitis) was seen in 34.7% (25/72). Late side effects ≥ grade 3 did not occur. Cosmetic results were rated as excellent/good in 96.7% (59/61). APBI with external beam radiotherapy techniques is feasible with low toxicity and, according to the results of the present and other studies, on the way to becoming a standard treatment option for a selected subgroup of patients. (orig.) [de

  17. Stereotactic external beam irradiation in previously untreated brain tumors in children and adolescents.

    Science.gov (United States)

    Freeman, C R; Souhami, L; Caron, J L; Villemure, J G; Olivier, A; Montes, J; Farmer, J P; Podgorsak, E B

    1994-01-01

    Stereotactically guided external beam irradiation may be a useful form of treatment for small, well-circumscribed, but surgically inaccessible, primary brain tumors that are either benign or of low malignant potential. Between March 1988 and December 1991, 10 children and adolescents with previously untreated primary brain tumors were treated with stereotactic external beam irradiation (SEBI) using a linac-based dynamic technique. Eleven lesions were treated in the 10 patients. Treatment was given using a collimator diameter of 1.5-4 cm (median 2 cm). Single fractions of 18, 20, and 25 Gy were used for 3 lesions in 2 patients. A fractionated schedule delivering a median dose of 42 Gy in 6 fractions over 2 weeks was used in the remaining 8 patients. Morbidity related to treatment was minimal. Three patients suffered a temporary worsening of preexisting neurological symptoms and/or signs at 2, 5, and 5 months posttreatment, with subsequent recovery in all. With a median follow up post-SEBI of 17.5 months (range 5-47 months), improvement in neurological findings related to the lesion was noted for 5 treated lesions; 6 remained clinically stable. Seven of the 11 treated lesions improved radiologically, and only 2 showed evidence of progressive disease. Stereotactic external beam irradiation represents a potentially valuable therapeutic option for selected primary brain tumors in the pediatric and adolescent age group. Morbidity related to the treatment appears acceptable in frequency and type, and preliminary data with regard to response are encouraging. However, in order to assess the impact of such treatment on long-term tumor control and survival, further experience with a larger cohort of patients followed for a longer period of time will be necessary.

  18. Elemental analysis of ancient Chinese bronze artifacts with external-beam PIXE

    International Nuclear Information System (INIS)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Shen, C.T.; Huang, Y.M.; Wu, S.C.; Hsieh, C.H.

    1992-01-01

    External-beam PIXE has been applied for the determination of the elemental composition of ancient Chinese bronze artifacts. Characteristic x-ray spectra from the samples bombarded with protons of 3 MeV have been measured with a HPGe detector. At each sample three spots were irradiated per run. Results of measurements on three fragments of bronze drinking vessels and helmet of Chinese ancient Chou and Shang dynasties (17th-8th century B.C.) are presented. To check the analytical method, we have also made measurements on the elemental composition of some modern coins. The results are discussed. (author)

  19. Non-destructive analysis of early glass unearthed in south China by external-beam PIXE

    International Nuclear Information System (INIS)

    Zhang, B.; Zhang, Z.Q.; Cheng, H.S.; Yang, F.J.; Li, Y.H.; Li, Q.H.; Ma, B.; Gan, F.X.; Fudan Univ., Shanghai

    2004-01-01

    External-beam PIXE was used for the non-destructive analysis of early glasses unearthed from the tombs of Warring States (475-221 BC) and Han Dynasty (BC 206-AD 220) in south China. It was found that these glasses were basically attributed to PbO-BaO-SiO 2 system and K 2 O-SiO 2 system. The results from the cluster analysis showed that some glasses had exactly the same recipe. The source of the K 2 O flux and the correlation between PbO and BaO are discussed. Some archaeological information is revealed. (author)

  20. Controlling laser ablation plasma with external electrodes. Application to sheath dynamics study and beam physics

    International Nuclear Information System (INIS)

    Isono, Fumika; Nakajima, Mitsuo; Hasegawa, Jun; Kawamura, Tohru; Horioka, Kazuhiko

    2013-01-01

    The potential of laser ablation plasma was controlled successfully by using external ring electrodes. We found that an electron sheath is formed at the plasma boundary, which plays an important role in the potential formation. When the positively biased plasma reaches a grounded grid, electrons in the plasma are turned away and ions are accelerated, which leads to the formation of a virtual anode between the grid and an ion probe. We think that this device which can raise the plasma potential up to order of kV can be applied to the study of sheath dynamics and to a new type of ion beam extraction. (author)

  1. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  2. Maxillofacial trauma patterns associated with external auditory canal fractures: Cone beam computed tomography analysis.

    Science.gov (United States)

    Ali, Ibrahim K; Sansare, Kaustubh; Karjodkar, Freny R; Salve, Prashant; Vanga, Kavita; Pawar, Ajinkya M

    2017-08-01

    There is a paucity of literature on external auditory canal (EAC) fractures secondary to maxillofacial trauma, with most of the literature on EAC fractures consisting of isolated case reports. To the authors' best knowledge, this is the first study to use cone beam computed tomography to evaluate the EAC region. The aim of this study was to assess the prevalence of external auditory canal (EAC) fracture following maxillofacial trauma and to evaluate the association between EAC fracture and other maxillofacial fractures and the region of trauma. One hundred patients were prospectively evaluated over 6 months from February to August 2016. The patients were referred for CBCT regarding temporomandibular joint or condylar fractures following maxillofacial trauma. Two observers (both experienced radiologists) assessed the EAC and associated fractures in the maxillofacial region. External auditory canal (EAC) fracture was confirmed in 32% of the patients. Of the EAC fractures, 68.75% and 31.25% were associated with mandibular fractures and non-mandibular fractures, respectively. Of the EAC fractures, 68.75% were single fractures and 31.25% of patients had multiple comminuted fractures. Significant association was observed on cross-tabulation of the fractured region and region of trauma with the presence of EAC fracture using chi-square test. External auditory canal (EAC) fracture is associated with maxillofacial fractures with increased incidence in mandibular fractures compared to non-mandibular fractures. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Neoadjuvant hormonal therapy and external-beam radiotherapy versus external-beam irradiation alone for prostate cancer. A quality-of-life analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pinkawa, Michael; Piroth, Marc D.; Asadpour, Branka; Gagel, Bernd; Fischedick, Karin; Siluschek, Jaroslav; Kehl, Mareike; Krenkel, Barbara; Eble, Michael J. [RWTH Aachen (Germany). Dept. of Radiotherapy

    2009-02-15

    To evaluate the impact of neoadjuvant hormonal therapy (NHT) on quality of life after external-beam radiotherapy (EBRT) for prostate cancer. A group of 170 patients (85 with and 85 without NHT) has been surveyed prospectively before EBRT (70.2-72 Gy), at the last day of EBRT, a median time of 2 months and 15 months after EBRT using a validated questionnaire (Expanded Prostate Cancer Index Composite). Pairs with and without NHT (median treatment time of 3.5 months before EBRT) were matched according to the respective planning target volume and prostate volume. Before EBRT, significantly lower urinary function/bother, sexual function and hormonal function/bother scores were found for patients with NHT. More than 1 year after EBRT, only sexual function scores remained lower. In a multivariate analysis, NHT and adjuvant hormonal therapy (HT) versus NHT only (hazard ratio 14; 95% confidence interval 2.7-183; p = 0.02) and luteinizing hormone-releasing hormone (LHRH) agonists versus antiandrogens (hazard ratio 3.6; 95% confidence interval 1.1-12; p = 0.04) proved to be independent risk factors for long-term erectile dysfunction (no or very poor ability to have an erection). With the exception of sexual function (additional adjuvant HT and application of LHRH analog independently adverse), short-term NHT was not found to decrease quality of life after EBRT for prostate cancer. (orig.)

  4. Development of a multi-detector and a systematic imaging system on the AGLAE external beam

    Energy Technology Data Exchange (ETDEWEB)

    Pichon, L., E-mail: laurent.pichon@culture.gouv.fr [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); Moignard, B.; Lemasson, Q.; Pacheco, C. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); Walter, P. [Fédération de recherche NewAGLAE, FR3506 CNRS/Ministère de la Culture/UPMC, Palais du Louvre, 75001 Paris (France); UPMC Univ Paris 06, CNRS-UMR 8220, Laboratoire d’archéologie moléculaire et structurale, LAMS, F-75005 Paris (France)

    2014-01-01

    The New AGLAE external beamline provides analytical data for the understanding of the structure of archaeological and artistic objects, their composition, properties, and changes over time. One of the objectives of this project is to design and set up a new non-invasive acquisition system increasing the quality of the X-ray spectra and reducing the beam current on sensitive materials from work of art. To that end, the surface and the number of PIXE detectors have been increased to implement a cluster of SDD detectors. This can also provide the possibility to accomplish large and/or fast maps on artifacts with a scanning of the beam on the sample. During the mapping, a multi-parameter system saves each event from X-ray, gamma and particle detectors, simultaneously with the X and Y positions of the beam on the sample. To process the data, different softwares have been developed or updated. A first example on a decorated medieval shard highlights the perspectives of the technique.

  5. Development of a multi-detector and a systematic imaging system on the AGLAE external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Moignard, B.; Lemasson, Q.; Pacheco, C.; Walter, P.

    2014-01-01

    The New AGLAE external beamline provides analytical data for the understanding of the structure of archaeological and artistic objects, their composition, properties, and changes over time. One of the objectives of this project is to design and set up a new non-invasive acquisition system increasing the quality of the X-ray spectra and reducing the beam current on sensitive materials from work of art. To that end, the surface and the number of PIXE detectors have been increased to implement a cluster of SDD detectors. This can also provide the possibility to accomplish large and/or fast maps on artifacts with a scanning of the beam on the sample. During the mapping, a multi-parameter system saves each event from X-ray, gamma and particle detectors, simultaneously with the X and Y positions of the beam on the sample. To process the data, different softwares have been developed or updated. A first example on a decorated medieval shard highlights the perspectives of the technique

  6. A new mapping acquisition and processing system for simultaneous PIXE-RBS analysis with external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Beck, L.; Walter, Ph.; Moignard, B.; Guillou, T.

    2010-01-01

    The combination of ion beam analysis techniques is particularly fruitful for the study of cultural heritage objects. For several years, the AGLAE facility of the Louvre laboratory has been implementing these techniques with an external beam. The recent set-up permits to carry out PIXE, PIGE and RBS simultaneously on the same analyzed spot with a particle beam of approximately 20 μm diameter. A new mapping system has been developed in order to provide elemental concentration maps from the PIXE and RBS spectra. This system combines the Genie2000 spectroscopy software with a homemade software that creates maps by handling acquisition with the object position. Each pixel of each PIXE and RBS maps contains the spectrum normalised by the dose. After analysing each pixel of the PIXE maps (low and high energy X-ray spectra) with the Gupixwin peak-fitting software, quantitative elemental concentrations are obtained for the major and trace elements. This paper presents the quantitative elemental maps extracted from the PIXE spectra and the development of RBS data processing for light element distribution and thin layer characterization. Examples on rock painting and lustrous ceramics will be presented.

  7. A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms

    International Nuclear Information System (INIS)

    Narayana, V.; Sahijdak, W.M.; Orton, C.G.

    1997-01-01

    Purpose: Radiation treatment of gynecological neoplasms, such as cervical carcinoma, usually combines external radiation therapy with one or more intracavitary brachytherapy applications. Although the dose from external beam radiation therapy and brachytherapy can be calculated and displayed in 3D individually, the dose distributions are not combined. At most, combined point doses are calculated for select points using various time-dose models. In this study, we present a methodology to combine external beam and brachytherapy treatments for gynecological neoplasms. Material and Methods: Three dimensional bio-effect treatment planning to obtain complication probability has been outlined. CT scans of the patient's pelvis with the gynecological applicator in place are used to outline normal tissue and tumor volumes. 3D external beam and brachytherapy treatment plans are developed separately and an external beam dose matrix and a brachytherapy dose matrix was calculated. The dose in each voxel was assumed to be homogeneous. The physical dose in each voxel of the dose matrix was then converted into extrapolated response dose (ERD) based on the linear quadratic model that accounts for the dose per fraction, number of fractions, dose rate, and complete or incomplete repair of sublethal damage (time between fractions). The net biological dose delivered was obtained by summing the ERD grids from external beam and brachytherapy since there was complete repair of sublethal damage between external beam and brachytherapy treatments. The normal tissue complication probability and tumor control probability were obtained using the biological dose matrix based on the critical element model. Results: The outlined method of combining external beam and brachytherapy treatments was implemented on gynecological treatments using an applicator for brachytherapy treatments. Conclusion: Implementation of the biological dose calculation that combine different modalities is extremely useful

  8. On finding the analytic dependencies of the external field potential on the control function when optimizing the beam dynamics

    Science.gov (United States)

    Ovsyannikov, A. D.; Kozynchenko, S. A.; Kozynchenko, V. A.

    2017-12-01

    When developing a particle accelerator for generating the high-precision beams, the injection system design is of importance, because it largely determines the output characteristics of the beam. At the present paper we consider the injection systems consisting of electrodes with given potentials. The design of such systems requires carrying out simulation of beam dynamics in the electrostatic fields. For external field simulation we use the new approach, proposed by A.D. Ovsyannikov, which is based on analytical approximations, or finite difference method, taking into account the real geometry of the injection system. The software designed for solving the problems of beam dynamics simulation and optimization in the injection system for non-relativistic beams has been developed. Both beam dynamics and electric field simulations in the injection system which use analytical approach and finite difference method have been made and the results presented in this paper.

  9. Provenance studies of Central European Neolithic obsidians using external beam milli-PIXE spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Constantinescu, B.; Cristea-Stan, D. [National Institute for Nuclear Physics and Engineering “Horia Hulubei”, Str. Reactorului No.3, Bucharest-Magurele (Romania); Kovács, I. [Wigner Research Centre for Physics, Institute for Particle and Nuclear Physics, Konkoly-Thege Miklós út 29-33, H-1121 Budapest (Hungary); Szőkefalvi-Nagy, Z., E-mail: szokefalvi-nagy@wigner.mta.hu [Wigner Research Centre for Physics, Institute for Particle and Nuclear Physics, Konkoly-Thege Miklós út 29-33, H-1121 Budapest (Hungary)

    2014-01-01

    External beam milli-PIXE technique was used for the determination of the elemental concentration ratios in some Prehistoric obsidian tools found in Transylvania, in the Iron Gates region near Danube, as well as on a few relevant geological obsidian samples from Slovak Tokaj Mountains, Lipari, Armenia. As provenance “fingerprints” the Ti to Mn and Rb to Zr ratios were used. The results confirm that the Transylvanian Neolithic samples have a Slovak Tokaj Mountains provenance. For Iron Gates samples, there are at least two different geological sources: for Late Neolithic tools, the origin is also the Slovak Tokaj Mountains but for Late Mesolithic–Early Neolithic samples, the sources are clearly different, possibly of the Hungarian Tokaj Mountains or the Balkan–Aegean origin.

  10. Multiple idiopathic external and internal resorption: Case report with cone-beam computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Celikten, Berkan; Uzuntas, Ceren Feriha; Kurt, Hakan [Faculty of Dentistry, Ankara University, Ankara (Turkmenistan)

    2014-12-15

    Root resorption is loss of dental hard tissue as a result of clastic activities. The dental hard tissue of permanent teeth does not normally undergo resorption, except in cases of inflammation or trauma. However, there are rare cases of tooth resorption of an unknown cause, known as 'idiopathic root resorption.' This report would discuss a rare case of multiple idiopathic resorption in the permanent maxillary and mandibular teeth of an otherwise healthy 36-year-old male patient. In addition to a clinical examination, the patient was imaged using conventional radiography and cone-beam computed tomography (CBCT). The examinations revealed multiple external and internal resorption of the teeth in all four quadrants of the jaws with an unknown cause. Multiple root resorption is a rare clinical phenomenon that should be examined using different radiographic modalities. Cross-sectional CBCT is useful in the diagnosis and examination of such lesions.

  11. Provenance studies of Central European Neolithic obsidians using external beam milli-PIXE spectroscopy

    International Nuclear Information System (INIS)

    Constantinescu, B.; Cristea-Stan, D.; Kovács, I.; Szőkefalvi-Nagy, Z.

    2014-01-01

    External beam milli-PIXE technique was used for the determination of the elemental concentration ratios in some Prehistoric obsidian tools found in Transylvania, in the Iron Gates region near Danube, as well as on a few relevant geological obsidian samples from Slovak Tokaj Mountains, Lipari, Armenia. As provenance “fingerprints” the Ti to Mn and Rb to Zr ratios were used. The results confirm that the Transylvanian Neolithic samples have a Slovak Tokaj Mountains provenance. For Iron Gates samples, there are at least two different geological sources: for Late Neolithic tools, the origin is also the Slovak Tokaj Mountains but for Late Mesolithic–Early Neolithic samples, the sources are clearly different, possibly of the Hungarian Tokaj Mountains or the Balkan–Aegean origin

  12. Multiple idiopathic external and internal resorption: Case report with cone-beam computed tomography findings

    International Nuclear Information System (INIS)

    Celikten, Berkan; Uzuntas, Ceren Feriha; Kurt, Hakan

    2014-01-01

    Root resorption is loss of dental hard tissue as a result of clastic activities. The dental hard tissue of permanent teeth does not normally undergo resorption, except in cases of inflammation or trauma. However, there are rare cases of tooth resorption of an unknown cause, known as 'idiopathic root resorption.' This report would discuss a rare case of multiple idiopathic resorption in the permanent maxillary and mandibular teeth of an otherwise healthy 36-year-old male patient. In addition to a clinical examination, the patient was imaged using conventional radiography and cone-beam computed tomography (CBCT). The examinations revealed multiple external and internal resorption of the teeth in all four quadrants of the jaws with an unknown cause. Multiple root resorption is a rare clinical phenomenon that should be examined using different radiographic modalities. Cross-sectional CBCT is useful in the diagnosis and examination of such lesions.

  13. An examination of human factors in external beam radiation therapy: Findings and implications

    International Nuclear Information System (INIS)

    Henriksen, K.; Kaye, R.D.; Jones, R.E. Jr.; Morisseau, D.S.; Persensky, J.J.

    1994-01-01

    To better understand the contributing factors to human error in external beam radiation therapy, the US Nuclear Regulatory Commission has undertaken a series of human factors evaluations. A team of human factors specialists, assisted by a panel of radiation oncologists, medical physicists, and radiation technologists, conducted visits to 24 radiation oncology departments at community hospitals, university centers, and free-standing clinics. A function and task analysis was initially performed to guide subsequent evaluations in the areas of human-system interfaces, procedures, training and qualifications, and organizational policies and practices. Representative findings and implications for improvement are discussed within the context of a dynamic model which holds that misadministration likely results from the unanticipated interaction of several necessary but singly insufficient conditions

  14. Differentiated Thyroid Cancer with Extrathyroidal Extension: Prognosis and the Role of External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Michael A. Sia

    2010-01-01

    Full Text Available A study was performed to identify variables that affected cause-specific survival (CSS and local relapse-free rate (LRFR in patients with differentiated thyroid cancer (DTC and extrathyroid extension (ETE and to examine the role of external beam radiotherapy (XRT. Prognostic factors were similar to those found in studies of all patients with DTC. In patients with postoperative gross residual disease treated with radiotherapy, 10-year CSS and LRFR were 48% and 90%. For patients with no residual or microscopic disease, 10-year CSS and LRFR were 92% and 93%. In patients older than 60 years with T3 ETE but no gross residual disease postoperatively there was an improved LRFR at 5 years of 96%, compared to 87.5% without XRT (P=.02. Patients with gross ETE benefit from XRT and there may be a potential benefit in reducing locoregional failure in patients over 60 years with minimal extrathyroidal extension (T3.

  15. Clinical results of iridium-192 high dose rate brachytherapy with external beam radiotherapy

    International Nuclear Information System (INIS)

    Nohara, Takahiro; Mizokami, Atsushi; Kumano, Tomoyasu

    2010-01-01

    Here, we report the clinical results of iridium-192 high dose rate brachytherapy at Kanazawa University Hospital. The study population consisted of 166 patients diagnosed with T1c-T3bN0M0 prostate cancer treated with high dose rate brachytherapy and external beam radiotherapy and followed up for 6 months or longer. Treatment consisted of external beam radiotherapy to the prostate at 44 Gy/22 fractions and high dose rate brachytherapy at 18 Gy/3 fractions. Median follow-up interval was 31.5 months (range 6.2-88.7). The overall 5-year biological recurrence-free survival rate was 93.0%. The 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups according to the D'Amico risk classification criteria were 96.1%, 89.0% and 91.6%, respectively. When limited to the group that did not receive adjuvant hormonal therapy, the 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups were 96.0%, 96.3% and 82.9%, respectively. Grade 3 or greater adverse effects were rare. Urethral stricture was observed in only 1.0% of the patients. Eighty percent of patients retained erectile function after high dose rate brachytherapy and reported satisfaction with sexual function. High dose rate brachytherapy is considered a good form of treatment for localized prostate cancer, although longer follow-up is necessary. (author)

  16. Serum testosterone levels after external beam radiation for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Zagars, Gunar K.; Pollack, Alan

    1997-01-01

    Purpose: To determine whether serum total testosterone levels change after external beam radiation therapy for localized prostate cancer. Methods and Materials: Eighty-five men with clinically localized prostate cancer (T1-T3, N0/NX, M0) who underwent external beam radiation therapy without androgen ablation had pretreatment and 3-month posttreatment total serum testosterone levels determined by radioimmunoassay. Scattered doses to the testicles were measured with thermoluminescent dosimetry in 10 men. Results: Pretreatment serum testosterone levels ranged from 185 to 783 ng/dl, with a mean of 400 ng/dl and a median of 390 ng/dl. The coefficient of variation was 30%. Postradiation 3-month testosterone levels ranged from 163 ng/dl to 796 ng/dl, with mean and median values of 356 ng/dl and 327 ng/ml, respectively. The coefficient of variation was 34%. The 3-month value was significantly lower than the pretreatment value (Wilcoxon paired p = 0.0001). The mean absolute fall was 94 ng/dl and the mean percentage fall was 9%. Although the fall in testosterone level was statistically significant, the difference was very small quantitatively. In contrast, serum prostate-specific antigen levels fell dramatically by 3 months after radiation. Testicular scattered doses ranged from 1.84 to 2.42 Gy, with a mean of 2.07 Gy for a prostatic tumor dose of 68 Gy. Conclusions: Although significant, the fall in serum testosterone level after radiation for localized prostate cancer was small and likely of no pathophysiologic consequence. It is unlikely that scattered testicular radiation plays any significant role in the genesis of this change in testosterone level, which most likely occurs as a nonspecific stress response

  17. Treatment of Head and Neck Paragangliomas With External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, Charles, E-mail: c.dupin@bordeaux.unicancer.fr [Department of Radiotherapy, Comprehensive Cancer Center, Institut Bergonié, Bordeaux (France); Lang, Philippe [Department of Radiotherapy, Pitié Salpétrière, Paris (France); Dessard-Diana, Bernadette [Department of Radiotherapy, Hopital Européen Georges Pompidou, Paris (France); Simon, Jean-Marc; Cuenca, Xavier; Mazeron, Jean-Jacques; Feuvret, Loïc [Department of Radiotherapy, Pitié Salpétrière, Paris (France)

    2014-06-01

    Purpose: To retrospectively assess the outcomes of radiation therapy in patients with head and neck paragangliomas. Methods and Materials: From 1990 to 2009, 66 patients with 81 head and neck paragangliomas were treated by conventional external beam radiation therapy in 25 fractions at a median dose of 45 Gy (range, 41.4-68 Gy). One case was malignant. The median gross target volume and planning target volume were 30 cm{sup 3} (range, 0.9-243 cm{sup 3}) and 116 cm{sup 3} (range, 24-731 cm{sup 3}), respectively. Median age was 57.4 years (range, 15-84 years). Eleven patients had multicentric lesions, and 8 had family histories of paraganglioma. Paragangliomas were located in the temporal bone, the carotid body, and the glomus vagal in 51, 18, and 10 patients, respectively. Forty-six patients had exclusive radiation therapy, and 20 had salvage radiation therapy. The median follow-up was 4.1 years (range, 0.1-21.2 years). Results: One patient had a recurrence of temporal bone paraganglioma 8 years after treatment. The actuarial local control rates were 100% at 5 years and 98.7% at 10 years. Patients with multifocal tumors and family histories were significantly younger (42 years vs 58 years [P=.002] and 37 years vs 58 years [P=.0003], respectively). The association between family predisposition and multifocality was significant (P<.001). Two patients had cause-specific death within the 6 months after irradiation. During radiation therapy, 9 patients required hospitalization for weight loss, nausea, mucositis, or ophthalmic zoster. Two late vascular complications occurred (middle cerebral artery and carotid stenosis), and 2 late radiation-related meningiomas appeared 15 and 18 years after treatment. Conclusion: Conventional external beam radiation therapy is an effective and safe treatment option that achieves excellent local control; it should be considered as a first-line treatment of choice for head and neck paragangliomas.

  18. Multicenter study differentiated thyroid carcinoma (MSDS). Diminished acceptance of adjuvant external beam radiotherapy

    International Nuclear Information System (INIS)

    Biermann, M.; Pixberg, M.K.; Schober, O.; Schuck, A.; Willich, N.; Heinecke, A.; Koepke, W.; Schmid, K.W.; Dralle, H.

    2003-01-01

    Aim: The Multicenter Study Differentiated Thyroid Carcinoma (MSDS) is an ongoing study in Germany, Austria, and Switzerland on the clinical benefit of adjuvant external beam radiotherapy (RTx) for locally invasive differentiated thyroid carcinoma (DTC) in TNM stages pT4 pNO/1/xMO/x (5th ed. 1997). Methods: MSDS was designed as a prospective randomized trial. Patients receive thyroidectomy, radioiodine therapy (RIT) to ablate the thyroid remnant, and TSH-suppressive L-thyroxine therapy with or without RTx after documented elimination of cervical iodine-131 uptake (http://msds-studie.uni-muenster.de). Results: 311 patients were enrolled between January 2000 and March 2003. 279 patients met the trial's inclusion criteria. 45 consented to randomization, of whom 17 were randomized into treatment arm A (RTx) and 18 into arm B (no RTx). Advised by the trial's independent Data Monitoring and Safety Committee, the MSDS steering committee decided to terminate randomization in April 2003 and continue MSDS as a prospective cohort study. 23 of the 234 patients in the observation arm of the trial were prescribed RTx by their physicians. Thus, 14% of the trial cohort were randomized or assigned to receive RTx (intention-to-treat analysis). In contrast, at least 44% of all patients with pT4 papillary DTC in Germany in the nationwide PCES study underwent RTx in 1996 (p 2 -test). Conclusions: Acceptance of external beam RTx as a treatment modality for DTC has receded to a degree that accrual of a sufficient number of patients for a randomized trial has been impossible. Observation of the trial cohort is continued in order to assess clinical event rates with and without RTx and chronic RTx toxicity. (orig.) [de

  19. External beam radiation therapy for squamous cell carcinoma of the soft palate

    International Nuclear Information System (INIS)

    Medini, Eitan; Medini, Allen; Gapany, Markus; Levitt, Seymour H.

    1997-01-01

    Purpose: External beam radiation therapy for carcinoma of the soft palate aims to achieve loco-regional control with normal speech, nasal function, swallowing mechanism, and minimal side effects such as nasal speech and regurgitation of food into the nasopharynx. In this report we present our results of radiotherapy in the treatment of 24 patients with squamous cell carcinoma of the soft palate. Methods and Materials: A total of 24 patients with squamous cell carcinoma of the soft palate were treated at the Veterans Administration Medical Center Minneapolis, MN, between February 1977 and May 1992. Of the 24 patients 2 had T1, 19 T2, 1 T3, and 2 had T4 lesions. Nineteen patients did not have clinical nodal disease, stage (N0), 1 had N1, 2 N2, and 2 N3 disease (Table 1). All the patients were treated by 4 MeV linear accelerator. A 1.75 Gy median dose was administered per fraction to a total of 70 Gy median dose. Bilateral opposed compensated shrinking fields technique was used. Results: The 3-year disease free survival rate after external beam radiation therapy was 100% (1 out of 1), 64.7% (11 out of 17), 100% (1 out of 1), and 0%, for patients with T1, T2, T3, and T4 disease, respectively. Salvage surgery for recurrent disease was successful in 57.1% (4 out of 7 patients). The ultimate 3-year disease free survival rate for the entire group, including surgical salvage, was 81% (17 out of 21). Conclusion: Radiation therapy alone in our institution resulted in tumor control and survival rates compare favorably to previously published reports in the literature. Surgery can be reserved as salvage procedure

  20. External beam radiotherapy for subretinal neovascularization in age-related macular degeneration: is this treatment efficient?

    International Nuclear Information System (INIS)

    Staar, Susanne; Krott, Ralf; Mueller, Rolf-Peter; Bartz-Schmidt, Karl U.; Heimann, Klaus

    1999-01-01

    Purpose: Control of the natural course of sub retinal neovascularization (SRNV) in age-related macular degeneration (AMD) is difficult. Only a subset of patients is suitable for laser coagulation. This prospective study aimed to determine the efficacy and individual benefit of external beam radiotherapy (EBRT). Methods and Materials: The prospective trial included 287 patients with subfoveal neovascularization due to AMD which was verified by fluorescein angiography. Patients have been treated between January 1996 and October 1997. All patients received a total dose of 16 Gy in 2-Gy daily fractions with 5-6 MeV photons based on computerized treatment planning in individual head mask fixation. This first analysis is based on 73 patients (50 women, 23 men, median age 74.3 years), with a median follow-up of 13.3 months and a minimum follow-up of 11 months. Results: All patients completed therapy and tolerability was good. First clinical control with second angiography was performed 6 weeks after irradiation, then in 3-month intervals. Eighteen patients with SRNV refusing radiotherapy served as a control group and were matched with 18 irradiated patients. After 7 months median visual acuity (VA) was 20/160 for the irradiated and 20/400 for the untreated patients. One year after radiotherapy final median VA was 20/400 in both groups. Conclusion: These results suggest that 16 Gy of conventionally fractionated external beam irradiation slows down the visual loss in exudative AMD for only a few months. Patients' reading vision could not be saved for a long-term run

  1. The external beam facility used to characterize corrosion products in metallic statuettes

    International Nuclear Information System (INIS)

    Rizzutto, M.A.; Tabacniks, M.H.; Added, N.; Barbosa, M.D.L.; Curado, J.F.; Santos, W.A.; Lima, S.C.; Melo, H.G.; Neiva, A.C.

    2005-01-01

    To open new possibilities in nuclear applied physics research, mainly for the analysis of art objects in air, an external beam facility was installed at LAMFI (Laboratorio de Analise de Materiais por Feixes Ionicos) of University of Sao Paulo. PIXE measurements were made using an XR-100CR (Si-PIN) X-ray detector pointed to the sample mounted after an approximate 11 mm air path, hence with effective beam energy of 0.9 MeV. This setup was used to characterize the corrosion products of two ethnological metallic statuettes from the African collection of the Museum of Archaeology and Etnology. PIXE analysis of the corrosion free base of one statuette showed that Cu and Zn are the main components of the alloy, while Pb is present in smaller amount. The analysis of some corrosion products showed a Zn:Cu relationship higher than that of the base, evidencing selective corrosion. The main components of the other statuette were Cu and Pb, while S and Zn were found in smaller amounts

  2. The external beam facility used to characterize corrosion products in metallic statuettes

    Science.gov (United States)

    Rizzutto, M. A.; Tabacniks, M. H.; Added, N.; Barbosa, M. D. L.; Curado, J. F.; Santos, W. A.; Lima, S. C.; Melo, H. G.; Neiva, A. C.

    2005-10-01

    To open new possibilities in nuclear applied physics research, mainly for the analysis of art objects in air, an external beam facility was installed at LAMFI (Laboratório de Análise de Materiais por Feixes Iônicos) of University of São Paulo. PIXE measurements were made using an XR-100CR (Si-PIN) X-ray detector pointed to the sample mounted after an approximate 11 mm air path, hence with effective beam energy of 0.9 MeV. This setup was used to characterize the corrosion products of two ethnological metallic statuettes from the African collection of the Museum of Archaeology and Etnology. PIXE analysis of the corrosion free base of one statuette showed that Cu and Zn are the main components of the alloy, while Pb is present in smaller amount. The analysis of some corrosion products showed a Zn:Cu relationship higher than that of the base, evidencing selective corrosion. The main components of the other statuette were Cu and Pb, while S and Zn were found in smaller amounts.

  3. Propagation characteristics of a focused laser beam in a strontium barium niobate photorefractive crystal under reverse external electric field.

    Science.gov (United States)

    Guo, Q L; Liang, B L; Wang, Y; Deng, G Y; Jiang, Y H; Zhang, S H; Fu, G S; Simmonds, P J

    2014-10-01

    The propagation characteristics of a focused laser beam in a SBN:75 photorefractive crystal strongly depend on the signal-to-background intensity ratio (R=Is/Ib) under reverse external electric field. In the range 20>R>0.05, the laser beam shows enhanced self-defocusing behavior with increasing external electric field, while it shows self-focusing in the range 0.03>R>0.01. Spatial solitons are observed under a suitable reverse external electric field for R=0.025. A theoretical model is proposed to explain the experimental observations, which suggest a new type of soliton formation due to "enhancement" not "screening" of the external electrical field.

  4. Non-rigid CT/CBCT to CBCT registration for online external beam radiotherapy guidance

    Science.gov (United States)

    Zachiu, Cornel; de Senneville, Baudouin Denis; Tijssen, Rob H. N.; Kotte, Alexis N. T. J.; Houweling, Antonetta C.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; Moonen, Chrit T. W.; Ries, Mario

    2018-01-01

    Image-guided external beam radiotherapy (EBRT) allows radiation dose deposition with a high degree of accuracy and precision. Guidance is usually achieved by estimating the displacements, via image registration, between cone beam computed tomography (CBCT) and computed tomography (CT) images acquired at different stages of the therapy. The resulting displacements are then used to reposition the patient such that the location of the tumor at the time of treatment matches its position during planning. Moreover, ongoing research aims to use CBCT-CT image registration for online plan adaptation. However, CBCT images are usually acquired using a small number of x-ray projections and/or low beam intensities. This often leads to the images being subject to low contrast, low signal-to-noise ratio and artifacts, which ends-up hampering the image registration process. Previous studies addressed this by integrating additional image processing steps into the registration procedure. However, these steps are usually designed for particular image acquisition schemes, therefore limiting their use on a case-by-case basis. In the current study we address CT to CBCT and CBCT to CBCT registration by the means of the recently proposed EVolution registration algorithm. Contrary to previous approaches, EVolution does not require the integration of additional image processing steps in the registration scheme. Moreover, the algorithm requires a low number of input parameters, is easily parallelizable and provides an elastic deformation on a point-by-point basis. Results have shown that relative to a pure CT-based registration, the intrinsic artifacts present in typical CBCT images only have a sub-millimeter impact on the accuracy and precision of the estimated deformation. In addition, the algorithm has low computational requirements, which are compatible with online image-based guidance of EBRT treatments.

  5. Finite Element Simulation of GFRP Reinforced Concrete Beam Externally Strengthened With CFRP Plates

    Directory of Open Access Journals (Sweden)

    Salleh Norhafizah

    2017-01-01

    Full Text Available The construction technology now has become more and more advanced allowing the development of new technologies or material to replace the previous one and also solved some of the troubles confronted by construction experts. The Glass Fibre Reinforced Polymer (GFRP composite is an alternative to replace the current usage of steel as it is rust proof and stronger in terms of stiffness compared to steel. Furthermore, GFRP bars have a high strength-to-weight ratio, making them attractive as reinforcement for concrete structures. However, the tensile behavior of GFRP bars is characterized by a linear elastic stress–strain relationship up to failure and, therefore, concrete elements reinforced with GFRP reinforcement exhibit brittle failure without warning. Design codes encourage over-reinforced GFRP design since it is more progressive and leads to a less catastrophic failure with a higher degree of deformability. Moreover, because of GFRP low modulus of elasticity, GFRP reinforced concrete members exhibit larger deflections and wider cracks width than steel reinforced concrete. This aims of this paper is to developed 2D Finite Element (FE models that can accurately simulate the respond on an improvement in the deflection of GFRP reinforced concrete beam externally strengthened with CFRP plates on the tension part of beam. The prediction of flexural response according to RCCSA software was also discussed. It was observed that the predicted FE results are given similar result with the experimental measured test data. Base on this good agreement, a parametric study was the performed using the validation FE model to investigate the effect of flexural reinforcement ratio and arrangement of the beams strengthened with different regions of CFRP plates.

  6. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, Adriana Gabriela [Division of Dental Diagnostic Science, Rutgers School of Dental Medicine, Newark (United States); Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel [University of Texas Health Science Center San Antonio, San Antonio (United States); Teixeira, Fabrico B. [Dept. of Endodontics, University of Iowa, Iowa City (United States)

    2015-09-15

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  7. Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption.

    Science.gov (United States)

    Creanga, Adriana Gabriela; Geha, Hassem; Sankar, Vidya; Teixeira, Fabricio B; McMahan, Clyde Alex; Noujeim, Marcel

    2015-09-01

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  8. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    International Nuclear Information System (INIS)

    Creanga, Adriana Gabriela; Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel; Teixeira, Fabrico B.

    2015-01-01

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption

  9. Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

    Science.gov (United States)

    Geha, Hassem; Sankar, Vidya; Teixeira, Fabricio B.; McMahan, Clyde Alex; Noujeim, Marcel

    2015-01-01

    Purpose The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption. PMID:26389057

  10. External beam irradiation inhibits neointimal hyperplasia after injury-induced arterial smooth muscle cell proliferation

    International Nuclear Information System (INIS)

    Schaefer, U.; Micke, O.; Dorszewski, A.; Breithardt, G.; Willich, N.

    1996-01-01

    Purpose/Objective: Restenosis after catheter-based revascularization has been demonstrated to be primarily caused by smooth muscle cell proliferation. This study examines the effects of external beam irradiation on neointimal proliferation after external injury to the central artery of the rabbit ear. Materials and Methods: 30 male New Zealand White rabbits were used in this study. Crush lesions were performed on each ear under general anesthesia and bilateral auricular nerve blockade. A single dose of 12 Gy (n=10), 16 Gy (n=10), or 20 Gy (n=10) gamma radiation was delivered to the left or right central artery of the ear 24 hours after injury; the contralateral central artery served as control. All rabbits were sacrificed after twenty-one days and the central arteries of the ear were fixed for morphometric measurements. Results: Mean (± SD) neointimal area was 0.062 ± 0.005 mm 2 (12 Gy), 0.022 ± 0.005 mm 2 (16 Gy) and 0.028 ± 0.006 mm 2 in irradiated arteries compared with 0.081 ± 0.009 mm 2 in the control group. Mean (± SD) luminal area was 0.049 ± 0.004 mm 2 (12 Gy), 0.059 ± 0.002 mm 2 (16 Gy) and 0.072 ± 0.006 mm 2 (24 Gy) in irradiated arteries compared with 0.043 ± 0.008 mm 2 in the control group. The difference in neointimal and luminal area between control and irradiated arteries was significant (p<0.05) only for the 16 and 20 Gy group compared to control. Conclusion: We conclude that in this model, external beam X-ray irradiation was successful in reducing neointimal proliferation after injury of the central artery of the rabbit ear. Marked reductions in neointimal proliferation were demonstrated in vessels subjected to 16 and 20 Gy radiation, a less prominent effect was noted for 12 Gy. Whether this approach can be used successfully to inhibit restenosis in the clinical setting requires further investigation

  11. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    Energy Technology Data Exchange (ETDEWEB)

    Constantinescu, B.; Cristea-Stan, D. [National Institute for Nuclear Physics and Engineering Horia Hulubei, Bucharest-Magurele (Romania); Kovács, I.; Szõkefalvi-Nagy, Z. [Wigner Research Centre for Phyics, Institute for Particle and Nuclear Physics, Budapest (Hungary)

    2013-07-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  12. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    International Nuclear Information System (INIS)

    Constantinescu, B.; Cristea-Stan, D.; Kovács, I.; Szõkefalvi-Nagy, Z.

    2013-01-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  13. A comparison of two methods for estimating the technical costs of external beam radiation therapy

    International Nuclear Information System (INIS)

    Hayman, James A.; Lash, Kathy A.; Tao, May L.; Halman, Marc A.

    2000-01-01

    Purpose: To accurately assess the cost-effectiveness of treatment with external beam radiation, it is necessary to have accurate estimates of its cost. One of the most common methods for estimating technical costs has been to convert Medicare charges into costs using Medicare Cost-to-Charge Ratios (CCR). More recently, health care organizations have begun to invest in sophisticated cost-accounting systems (CAS) that are capable of providing procedure-specific cost estimates. The purpose of this study was to examine whether these competing approaches result in similar cost estimates for four typical courses of external beam radiation therapy (EBRT). Methods and Materials: Technical costs were estimated for the following treatment courses: 1) a palliative 'simple' course of 10 fractions using a single field without blocks; 2) a palliative 'complex' course of 10 fractions using two opposed fields with custom blocks; 3) a curative course of 30 fractions for breast cancer using tangent fields followed by an electron beam boost; and 4) a curative course of 35 fractions for prostate cancer using CT-planning and a 4-field technique. Costs were estimated using the CCR approach by multiplying the number of units of each procedure billed by its Medicare charge and CCR and then summing these costs. Procedure-specific cost estimates were obtained from a cost-accounting system, and overall costs were then estimated for the CAS approach by multiplying the number of units billed by the appropriate unit cost estimate and then summing these costs. All costs were estimated using data from 1997. The analysis was also repeated using data from another academic institution to estimate their costs using the CCR and CAS methods, as well as the appropriate relative value units (RVUs) and conversion factor from the 1997 Medicare Fee Schedule to estimate Medicare reimbursement for the four treatment courses. Results: The estimated technical costs for the CCR vs. CAS approaches for the four

  14. A comparison of two methods for estimating the technical costs of external beam radiation therapy.

    Science.gov (United States)

    Hayman, J A; Lash, K A; Tao, M L; Halman, M A

    2000-05-01

    To accurately assess the cost-effectiveness of treatment with external beam radiation, it is necessary to have accurate estimates of its cost. One of the most common methods for estimating technical costs has been to convert Medicare charges into costs using Medicare Cost-to-Charge Ratios (CCR). More recently, health care organizations have begun to invest in sophisticated cost-accounting systems (CAS) that are capable of providing procedure-specific cost estimates. The purpose of this study was to examine whether these competing approaches result in similar cost estimates for four typical courses of external beam radiation therapy (EBRT). Technical costs were estimated for the following treatment courses: 1) a palliative "simple" course of 10 fractions using a single field without blocks; 2) a palliative "complex" course of 10 fractions using two opposed fields with custom blocks; 3) a curative course of 30 fractions for breast cancer using tangent fields followed by an electron beam boost; and 4) a curative course of 35 fractions for prostate cancer using CT-planning and a 4-field technique. Costs were estimated using the CCR approach by multiplying the number of units of each procedure billed by its Medicare charge and CCR and then summing these costs. Procedure-specific cost estimates were obtained from a cost-accounting system, and overall costs were then estimated for the CAS approach by multiplying the number of units billed by the appropriate unit cost estimate and then summing these costs. All costs were estimated using data from 1997. The analysis was also repeated using data from another academic institution to estimate their costs using the CCR and CAS methods, as well as the appropriate relative value units (RVUs) and conversion factor from the 1997 Medicare Fee Schedule to estimate Medicare reimbursement for the four treatment courses. The estimated technical costs for the CCR vs. CAS approaches for the four treatment courses were as follows

  15. Prospective Phase II Study of Brachytherapy Boost as a Component of Neo-Adjuvant Chemotherapy and External Beam Radiation Therapy in Locally Advanced Rectal Cancer

    International Nuclear Information System (INIS)

    EL-SAYED, M.E.; EL-TAHER, Z.H.

    2008-01-01

    The aim of the current study is to assess the response rate and toxicity profile in patients with locally advanced rectal cancer using brachytherapy (BT) boost following external beam radiotherapy (EBRT), concomitant with chemotherapy as a component of the neoadjuvant treatment. Patients and Methods: This is a prospective phase II study of neoadjuvant chemo-radiation therapy for patients with locally advanced rectal cancer who presented to the department of radiation oncology, King Abdul-Aziz University Hospital, Jeddah, Kingdom of Saudi Arabia. Seventeen patients had been included in the study. Radiation therapy was given as: phase I,45 Gy/25 fractions/5 weeks of EBRT, followed by brachytherapy boost (within one week after the end of EBRT) using high dose rate iridium 192 (Ir 192 ) aiming at 800 c Gy given in 2 fractions (each 400 c Gy) separated by 1 week. All patients received the same concomitant chemotherapy in the form of Capecitabine and Oxaliplatin. The clinical and pathological response rates, together with the toxicity profile were assessed. Results: Seventeen patients had been studied; the majority (14; 82%) were males, while 3 only (18%) were females, their mean age was 57.4 years. All patients had low anterior resection (LAR). The clinical response rate, assessed by digital rectal examination ± endoscopy examination 4 weeks after the end of EBRT and BT, revealed that complete clinical response (cCR) was noted in 3 patients (18%), clinical partial response (cPR) in 14 patients (82%); while the pathological response rate was: complete pathological response (pCR) in 8 patients (47%), pathological partial response (pPR) in 9 patients (53%). The toxicity profile showed that grade III radiation proctitis was seen in one patient (6%), grade III dermatitis in 2 (12%), while no patients developed grade III cystitis. For chemotherapy toxicities, three patients (18%) developed grade III nausea and/or vomiting, 2 (12%) developed grade III diarrhea. Conclusion

  16. Accelerated partial breast irradiation with external beam radiotherapy. First results of the German phase 2 trial

    Energy Technology Data Exchange (ETDEWEB)

    Ott, Oliver J.; Strnad, Vratislav; Stillkrieg, Wilhelm; Fietkau, Rainer [University Hospital Erlangen, Department of Radiation Oncology, Erlangen (Germany); Uter, Wolfgang [University Erlangen-Nuremberg, Dept. of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Beckmann, Matthias W. [University Hospital Erlangen, Dept. of Gynecology, Erlangen (Germany)

    2017-01-15

    To evaluate the feasibility and efficacy of external beam three-dimensional (3D) conformal accelerated partial breast irradiation (APBI) for selected patients with early breast cancer. Between 2011 and 2016, 72 patients were recruited for this prospective phase 2 trial. Patients were eligible for APBI if they had histologically confirmed breast cancer or pure ductal carcinoma in situ (DCIS), a tumor diameter ≤3 cm, clear resection margins ≥2 mm, no axillary lymph node involvement, no distant metastases, tumor bed clips, and were aged ≥50 years. Patients were excluded if mammography showed a multicentric invasive growth pattern, or if they had residual diffuse microcalcifications postoperatively, an extensive intraductal component, or vessel invasion. Patients received 3D conformal external beam APBI with a total dose of 38 Gy in 10 fractions in 1-2 weeks. The trial had been registered at the German Clinical Trials Register, DRKS-ID: DRKS00004417. Median follow-up was 25.5 months (range 1-61 months). Local control was maintained in 71 of 72 patients. The 3-year local recurrence rate was 2.1% (95% confidence interval, CI: 0-6.1%). Early toxicity (grade 1 radiodermatitis) was seen in 34.7% (25/72). Late side effects ≥ grade 3 did not occur. Cosmetic results were rated as excellent/good in 96.7% (59/61). APBI with external beam radiotherapy techniques is feasible with low toxicity and, according to the results of the present and other studies, on the way to becoming a standard treatment option for a selected subgroup of patients. (orig.) [German] Untersuchung der Vertraeglichkeit und Sicherheit der externen, 3-D-konformalen akzelerierten Teilbrustbestrahlung (APBI) fuer ausgewaehlte Patientinnen mit einem fruehen Mammakarzinom. Von 2011 bis 2016 wurden 72 Patientinnen in diese prospektive Phase-2-Studie eingebracht. Einschlusskriterien waren ein histologisch gesichertes Mammakarzinom oder DCIS, ein Tumordurchmesser ≤ 3 cm, tumorfreie Resektionsraender ≥ 2

  17. Sequential versus "sandwich" sequencing of adjuvant chemoradiation for the treatment of stage III uterine endometrioid adenocarcinoma.

    Science.gov (United States)

    Lu, Sharon M; Chang-Halpenny, Christine; Hwang-Graziano, Julie

    2015-04-01

    To compare the efficacy and tolerance of adjuvant chemotherapy and radiotherapy delivered in sequential (chemotherapy followed by radiation) versus "sandwich" fashion (chemotherapy, interval radiation, and remaining chemotherapy) after surgery in patients with FIGO stage III uterine endometrioid adenocarcinoma. From 2004 to 2011, we identified 51 patients treated at our institution fitting the above criteria. All patients received surgical staging followed by adjuvant chemoradiation (external-beam radiation therapy (EBRT) with or without high-dose rate (HDR) vaginal brachytherapy (VB)). Of these, 73% and 27% of patients received their adjuvant therapy in sequential and sandwich fashion, respectively. There were no significant differences in clinical or pathologic factors between patients treated with either regimen. Thirty-nine (76%) patients had stage IIIC disease. The majority of patients received 6 cycles of paclitaxel with carboplatin or cisplatin. Median EBRT dose was 45 Gy and 54% of patients received HDR VB boost (median dose 21 Gy). There were no significant differences in the estimated 5-year overall survival, local progression-free survival, and distant metastasis-free survival between the sequential and sandwich groups: 87% vs. 77% (p=0.37), 89% vs. 100% (p=0.21), and 78% vs. 85% (p=0.79), respectively. No grade 3-4 genitourinary or gastrointestinal toxicities were reported in either group. There was a trend towards higher incidence of grade 3-4 hematologic toxicity in the sandwich group. Adjuvant chemoradiation for FIGO stage III endometrioid uterine cancer given in either sequential or sandwich fashion appears to offer equally excellent early clinical outcomes and acceptably low toxicity. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Rectum separation in patients with cervical cancer for treatment planning in primary chemo-radiation

    Directory of Open Access Journals (Sweden)

    Marnitz Simone

    2012-07-01

    Full Text Available Abstract Purpose To proof feasibility of hydrogel application in patients with advanced cervical cancer undergoing chemo-radiation in order to reduce rectal toxicity from external beam radiation as well as brachytherapy. Material and methods Under transrectal sonographic guidance five patients with proven cervical cancer underwent hydro gel (20 cc instillation into the tip of rectovaginal septum adherent to posterior part of the visible cervical tumor. Five days after this procedure all patients underwent T2 weighted transversal and sagittal MRI for brachytherapy planning. MRI protocol included T2 weighted fast spin echo (FSE imaging in sagittal, coronal and para-axial orientation using an 1.5 Tesla MRI. Separation of anterior rectal wall and cervix was documented. Results Hydrogel application was uneventful in all patients and no toxicity was reported. Separation ranged from 7 to 26 mm in width (median 10 mm. The length of the separation varied between 18 and 38 mm (median 32 mm. In all patients displacement was seen in the posterior vaginal fornix, and/or at the deepest part of uterine cervix depending on the extension of the cul-de-sac in correlation to the posterior wall of the uterus. In patients with bulky tumor and/or deep (vaginal extend of peritoneal cavity tumour was seen mainly cranial from the rectovaginal space and therefore above the hydrogeI application. Only in the extra-peritoneal (lower part of the cervix a good separation could be achieved between the rectum and cervix. Conclusion Hydrgel instillation in patients with cervial cancer undergoing chemoradiation is safe and feasible. Because of the loose tissue of the cul-de-sac and its intra- and extraperitoneal part, hydrogel instillation of 20 cc did not result in a sufficient separation of the cervix from anterior wall.

  19. Rectum separation in patients with cervical cancer for treatment planning in primary chemo-radiation

    International Nuclear Information System (INIS)

    Marnitz, Simone; Budach, Volker; Weißer, Friederike; Burova, Elena; Gebauer, Bernhard; Vercellino, Filiberto Guiseppe; Köhler, Christhardt

    2012-01-01

    To proof feasibility of hydrogel application in patients with advanced cervical cancer undergoing chemo-radiation in order to reduce rectal toxicity from external beam radiation as well as brachytherapy. Under transrectal sonographic guidance five patients with proven cervical cancer underwent hydro gel (20 cc) instillation into the tip of rectovaginal septum adherent to posterior part of the visible cervical tumor. Five days after this procedure all patients underwent T2 weighted transversal and sagittal MRI for brachytherapy planning. MRI protocol included T2 weighted fast spin echo (FSE) imaging in sagittal, coronal and para-axial orientation using an 1.5 Tesla MRI. Separation of anterior rectal wall and cervix was documented. Hydrogel application was uneventful in all patients and no toxicity was reported. Separation ranged from 7 to 26 mm in width (median 10 mm). The length of the separation varied between 18 and 38 mm (median 32 mm). In all patients displacement was seen in the posterior vaginal fornix, and/or at the deepest part of uterine cervix depending on the extension of the cul-de-sac in correlation to the posterior wall of the uterus. In patients with bulky tumor and/or deep (vaginal) extend of peritoneal cavity tumour was seen mainly cranial from the rectovaginal space and therefore above the hydrogeI application. Only in the extra-peritoneal (lower) part of the cervix a good separation could be achieved between the rectum and cervix. Hydrgel instillation in patients with cervial cancer undergoing chemoradiation is safe and feasible. Because of the loose tissue of the cul-de-sac and its intra- and extraperitoneal part, hydrogel instillation of 20 cc did not result in a sufficient separation of the cervix from anterior wall

  20. Research of transportation efficiency of low-energy high- current electron beam in plasma channel in external magnetic field

    International Nuclear Information System (INIS)

    Vagin, E S; Grigoriev, V P

    2015-01-01

    Effective high current (5-20 kA) and low energy (tens of keV) electrons beam transportation is possible only with almost complete charging neutralization. It is also necessary to use quite high current neutralization for elimination beam self-pinching effect. The research is based on the self-consistent mathematical model that takes into account beam and plasma particles dynamic, current and charge neutralization of electron beam and examines the transportation of electron beam into a chamber with low-pressure plasma in magnetic field. A numerical study was conducted using particle in cell (PIC) method. The study was performed with various system parameters: rise time and magnitude of the beam current, gas pressure and plasma density and geometry of the system. Regularities of local virtual cathode field generated by the beam in the plasma channel, as well as ranges of parameters that let transportation beam with minimal losses, depending on the external magnetic field were determined through a series of numerical studies. In addition, the assessment of the impact of the plasma ion mobility during the transition period and during steady beam was performed. (paper)

  1. Internal hemipelvectomy with intraoperative and external beam radiotherapy in the limb-sparing treatment of a pelvic girdle chondrosarcoma

    NARCIS (Netherlands)

    Hoekstra, HJ; Szabo, BG

    The case of a patient with an extensive pelvic girdle chondrosarcoma treated with internal hemipelvectomy and intraoperative radiotherapy, followed by adjuvant high-dose external beam radiotherapy, with a successful attempt in achieving long-term local tumor control and limb-sparing treatment is

  2. Validated image fusion of dedicated PET and CT for external beam radiation and therapy in the head and neck area.

    NARCIS (Netherlands)

    Vogel, W.V.; Schinagl, D.A.X.; Dalen, J.A. van; Kaanders, J.H.A.M.; Oyen, W.J.G.

    2008-01-01

    AIM: Integration of positron emission tomography (PET) information into computer tomography (CT)- based intensity modulated external beam radiation therapy (IMRT) allows adaptation of the target volume to functional parameters, but only when the image registration procedure is reliable. The aim of

  3. Optimum location of external markers using feature selection algorithms for real-time tumor tracking in external-beam radiotherapy: a virtual phantom study.

    Science.gov (United States)

    Nankali, Saber; Torshabi, Ahmad Esmaili; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-08

    In external-beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation-based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two "Genetic" and "Ranker" searching procedures. The performance of these algorithms has been evaluated using four-dimensional extended cardiac-torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro-fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F-test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation-based feature selection algorithm, in

  4. Salvage external beam radiotherapy for clinical failure after cryosurgery for prostate cancer

    International Nuclear Information System (INIS)

    McDonough, Michael J.; Feldmeier, John J.; Parsai, Ishmael; Dobelbower, Ralph R.; Selman, Steven H.

    2001-01-01

    Purpose: To investigate the role of external beam radiotherapy (EBRT) as salvage treatment of prostate cancer after cryosurgery failure. Methods and Materials: Between 1993 and 1998, 6 patients underwent EBRT with curative intent for local recurrence of prostate cancer after cryosurgery. All 6 patients had biopsy-proven recurrence and palpable disease on digital rectal examination at the time of EBRT. The median follow-up was 34 months (range 8-46). The median prostate-specific antigen level was 2.3 ng/mL (range 0.8-4.1). No patient had evidence of metastatic disease. Two patients received hormonal therapy before beginning EBRT. No patient received hormonal therapy after EBRT completion. The median elapsed time between cryosurgery and EBRT was 3 years (range 1.5-4). The median delivered dose was 66 Gy (range 62-70.2) using a 10-MeV photon beam. An in-house-developed three-dimensional treatment planning system was used to plan delivery of the prescribed dose with conformal radiotherapy techniques. Results: After EBRT, all patients had complete resolution of palpable disease. Four patients (66%) were disease free at the time of the last follow-up. Two patients developed biochemical failure as defined by the American Society for Therapeutic Radiology and Oncology consensus definition. One of these patients had a prostate-specific antigen level of 97 ng/mL before cryosurgery. No patient developed distant metastasis during follow-up. Two patients (33%) developed proctitis; 1 case resolved with Rowasa suppositories and 1 required blood transfusion. Conclusions: Our preliminary results suggest that EBRT can render a significant number of patients biochemically free of disease and can cause complete resolution of clinically palpable disease after initial cryosurgery. The results also showed that EBRT can be given without excessive morbidity. EBRT should be considered as a treatment option in these potentially curable cases

  5. Peripheral photon and neutron doses from prostate cancer external beam irradiation.

    Science.gov (United States)

    Bezak, Eva; Takam, Rundgham; Marcu, Loredana G

    2015-12-01

    Peripheral photon and neutron doses from external beam radiotherapy (EBRT) are associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose estimations of secondary radiation are imperative. Peripheral photon and neutron doses from EBRT of prostate carcinoma were measured in Rando phantom. (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescence dosemeters (TLDs) were inserted in slices of a Rando phantom followed by exposure to 80 Gy with 18-MV photon four-field 3D-CRT technique. The TLDs were calibrated using 6- and 18-MV X-ray beam. Neutron dose equivalents measured with CR-39 etch-track detectors were used to derive readout-to-neutron dose conversion factor for (6)LiF:Mg,Cu,P TLDs. Average neutron dose equivalents per 1 Gy of isocentre dose were 3.8±0.9 mSv Gy(-1) for thyroid and 7.0±5.4 mSv Gy(-1) for colon. For photons, the average dose equivalents per 1 Gy of isocentre dose were 0.2±0.1 mSv Gy(-1) for thyroid and 8.1±9.7 mSv Gy(-1) for colon. Paired (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P TLDs can be used to measure photon and neutron doses simultaneously. Organs in close proximity to target received larger doses from photons than those from neutrons whereas distally located organs received higher neutron versus photon dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. SU-F-T-242: A Method for Collision Avoidance in External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: We proposed a method for collision avoidance (CA) in external beam radiation therapy (EBRT). The method encompasses the analysis of all positions of the moving components of the beam delivery system such as the treatment table and gantry, including patient specific information obtained from the CT images. This method eliminates the need for time-consuming dry-runs prior to the actual treatments. Methods: The QA procedure for EBRT requires that the collision should be checked prior to treatment. We developed a system capable of a rigorous computer simulation of all moving components including positions of the couch and gantry during the delivery, position of the patients, and imaging equipment. By running this treatment simulation it is possible to quantify and graphically represent all positions and corresponding trajectories of all points of the moving parts during the treatment delivery. The development of the workflow for implementation of the CA includes several steps: a) derivation of combined dynamic equation of motion of the EBRT delivery systems, b) developing the simulation model capable of drawing the motion trajectories of the specific points, c) developing the interface between the model and the treatment plan parameters such as couch and gantry parameters for each field. Results: The patient CT images were registered to the treatment couch so the patient dimensions were included into the simulation. The treatment field parameters were structured in the xml-file which was used as the input into the dynamic equations. The trajectories of the moving components were plotted on the same graph using the dynamic equations. If the trajectories intersect that was the signal that collision exists. Conclusion: This CA method was proved to be effective in the simulation of treatment delivery. The proper implementation of this system can potentially improve the QA program and increase the efficacy in the clinical setup.

  7. Improving efficiency and safety in external beam radiation therapy treatment delivery using a Kaizen approach.

    Science.gov (United States)

    Kapur, Ajay; Adair, Nilda; O'Brien, Mildred; Naparstek, Nikoleta; Cangelosi, Thomas; Zuvic, Petrina; Joseph, Sherin; Meier, Jason; Bloom, Beatrice; Potters, Louis

    Modern external beam radiation therapy treatment delivery processes potentially increase the number of tasks to be performed by therapists and thus opportunities for errors, yet the need to treat a large number of patients daily requires a balanced allocation of time per treatment slot. The goal of this work was to streamline the underlying workflow in such time-interval constrained processes to enhance both execution efficiency and active safety surveillance using a Kaizen approach. A Kaizen project was initiated by mapping the workflow within each treatment slot for 3 Varian TrueBeam linear accelerators. More than 90 steps were identified, and average execution times for each were measured. The time-consuming steps were stratified into a 2 × 2 matrix arranged by potential workflow improvement versus the level of corrective effort required. A work plan was created to launch initiatives with high potential for workflow improvement but modest effort to implement. Time spent on safety surveillance and average durations of treatment slots were used to assess corresponding workflow improvements. Three initiatives were implemented to mitigate unnecessary therapist motion, overprocessing of data, and wait time for data transfer defects, respectively. A fourth initiative was implemented to make the division of labor by treating therapists as well as peer review more explicit. The average duration of treatment slots reduced by 6.7% in the 9 months following implementation of the initiatives (P = .001). A reduction of 21% in duration of treatment slots was observed on 1 of the machines (P Kaizen approach has the potential to improve operational efficiency and safety with quick turnaround in radiation therapy practice by addressing non-value-adding steps characteristic of individual department workflows. Higher effort opportunities are identified to guide continual downstream quality improvements. Copyright © 2017 American Society for Radiation Oncology. Published by

  8. The Outcome of Conventional External Beam Radiotherapy for Patients with Squamous Cell Carcinoma of the Esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Young [Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2008-03-15

    The best treatment for advanced esophageal cancer is chemoradiotherapy followed by surgery. In spite of the advance of multimodality therapy, most patients with esophageal cancer are treated with radiation therapy alone. This study reports the outcome of the use of conventional external beam radiotherapy alone for the treatment of esophageal cancer. Between January 1998 and December 2005, 30 patients with squamous cell carcinoma of the esophagus were treated with external beam radiotherapy using a total dose exceeding 40 Gy. Radiotherapy was delivered with a total dose of 44-60 Gy (median dose, 57.2 Gy) over 36 {approx}115 days (median time, 45 days). Thirteen patients (43.3%) had a history of disorders such as diabetes, hypertension, tuberculosis, lye stricture, asthma, cerebral infarct, and cancers. Four patients metachronously had double primary cancers. The most common location of a tumor was the mid-thoracic portion of the esophagus (56.7%). Tumor lengths ranged from 2 cm to 11 cm, with a median length of 6 cm. For AJCC staging, stage III was the most common (63.3%). Five patients had metastases at diagnosis. The median overall survival was 8.3 months. The survival rates at 1-year and 2-years were 33.3% and 18.7%, respectively. The complete response rate 1{approx}3 months after radiotherapy was 20% (6/30) and the partial response rate was 70% (21/30). Sixteen patients (53.3%) had an improved symptom of dysphagia. Significant prognostic factors were age, tumor length, stage, degree of dysphagia at the time of diagnosis and tumor response. Cox regression analysis revealed the aim of treatment, clinical tumor response and tumor length as independent prognostic factors for overall survival. Twenty-eight patients had local failure and another four patients had metastases. Three patients were detected with double primary cancers in this analysis. A complication of esophageal stricture was observed in three patients (10%), and radiation pneumonitis occurred in two

  9. External Beam Radiotherapy Affects Serum Testosterone in Patients With Localized Prostate Cancer.

    Science.gov (United States)

    Pompe, Raisa S; Karakiewicz, Pierre I; Zaffuto, Emanuele; Smith, Ariane; Bandini, Marco; Marchioni, Michele; Tian, Zhe; Leyh-Bannurah, Sami-Ramzi; Schiffmann, Jonas; Delouya, Guila; Lambert, Carole; Bahary, Jean-Paul; Beauchemin, Marie Claude; Barkati, Maroie; Ménard, Cynthia; Graefen, Markus; Saad, Fred; Tilki, Derya; Taussky, Daniel

    2017-07-01

    Previous studies have examined testosterone levels after external beam radiation (EBRT) monotherapy, but since 2002 only sparse contemporary data have been reported. To examine testosterone kinetics in a large series of contemporary patients after EBRT. The study was conducted in 425 patients who underwent definitive EBRT for localized prostate cancer from 2002 through 2014. Patients were enrolled in several phase II and III trials. Exclusion criteria were neoadjuvant or adjuvant androgen-deprivation therapy or missing data. Testosterone was recorded at baseline and then according to each study protocol (not mandatory in all protocols). Statistical analyses consisted of means and proportions, Kaplan-Meier plots, and logistic and Cox regression analyses. Testosterone kinetics after EBRT monotherapy and their influence on biochemical recurrence. Median follow-up of 248 assessable patients was 72 months. One hundred eighty-six patients (75.0%) showed a decrease in testosterone. Median time to first decrease was 6.4 months. Median percentage of decrease to the nadir was 30% and 112 (45.2%) developed biochemical hypogonadism (serum testosterone testosterone decrease, 117 (62.9%) recovered to at least 90% of baseline levels. Advanced age, increased body mass index, higher baseline testosterone level, and lower nadir level were associated with a lower chance of testosterone recovery. Subgroup analyses of 166 patients treated with intensity-modulated radiotherapy confirmed the results recorded for the entire cohort. In survival analyses, neither testosterone decrease nor recovery was predictive for biochemical recurrence. EBRT monotherapy influences testosterone kinetics, and although most patients will recover, approximately 45% will have biochemical hypogonadism. We report on the largest contemporary series of patients treated with EBRT monotherapy in whom testosterone kinetics were ascertained. Limitations are that testosterone follow-up was not uniform and the study

  10. A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakar, Ramachandran; Cramb, Jim; Kron, Tomas [Physical Sciences, Peter MacCallum Cancer Centre, Locked Bag 1, A' Beckett Street, Victoria 8006 (Australia)

    2011-12-15

    Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry

  11. Time of Decline in Sexual Function After External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Siglin, Joshua; Kubicek, Gregory J.; Leiby, Benjamin; Valicenti, Richard K.

    2010-01-01

    Purpose: Erectile dysfunction is one of the most concerning toxicities for patients in the treatment of prostate cancer. The inconsistent evaluation of sexual function (SF) and limited follow-up data have necessitated additional study to clarify the rate and timing of erectile dysfunction after external beam radiotherapy (EBRT) for prostate cancer. Methods and Materials: A total of 143 men completed baseline data on SF before treatment and at the subsequent follow-up visits. A total of 1187 validated SF inventories were analyzed from the study participants. Multiple domains of SF (sex drive, erectile function, ejaculatory function, and overall satisfaction) were analyzed for ≤8 years of follow-up. Results: The median follow-up was 4.03 years. The strongest predictor of SF after EBRT was SF before treatment. For all domains of SF, the only statistically significant decrease in function occurred in the first 24 months after EBRT. SF stabilized 2 years after treatment completion, with no statistically significant change in any area of SF >2 years after the end of EBRT. Conclusion: These data suggest that SF does not have a continuous decline after EBRT. Instead, SF decreases maximally within the first 24 months after EBRT, with no significant changes thereafter.

  12. Preirradiation PSA predicts biochemical disease-free survival in patients treated with postprostatectomy external beam irradiation

    International Nuclear Information System (INIS)

    Crane, Christopher H.; Rich, Tyvin A.; Read, Paul W.; Sanfilippo, Nicholas J.; Gillenwater, Jay Y.; Kelly, Maria D.

    1997-01-01

    Purpose: To assess the clinical outcome and prostate-specific antigen (PSA) response and to determine prognostic factors for biochemical disease-free survival in patients treated with external beam radiotherapy following radical prostatectomy without hormonal therapy. Methods and Materials: Forty-eight patients were treated after prostatectomy with radiotherapy between March, 1988 and December, 1993. Seven patients had undetectable PSA ( 2.7. Five-year actuarial biochemical disease-free survival values were 71, 48, and 0%, respectively, for the three groups. Biochemical disease-free survival was not affected by preoperative PSA level, clinical stage, Gleason's score, pathologic stage, surgical margins, presence of undetectable PSA after surgery, surgery to radiation interval, total dose, or presence of clinically suspicious local disease. Based on digital rectal exam, there were no local failures. Conclusion: Biochemical disease-free survival after postprostatectomy radiation is predicted by the PSA at the time of irradiation. Clinical local control is excellent, but distant failure remains a significant problem in this population. The addition of concomitant systemic therapy should be investigated in patients with PSA >2.7

  13. Treatment of locally advanced breast carcinoma with high-dose external beam supervoltage radiotherapy

    International Nuclear Information System (INIS)

    Brufman, G.; Weshler, Z.; Prosnitz, L.R.; Fuks, Z.

    1981-01-01

    Between 1960 and 1978, 87 patients with locally advanced Tsub(3-4)Nsub(0-3)M 0 carcinoma of the breast were treated with 5,000 to 8,000 rad of external beam supervoltage radiotherapy. Initial clinical eradication of the tumour was observed in 76 of 87 cases (87%), but the actuarial probability of local control at 5 yr was only 53%. Furthermore, the actuarial probability of disease-free survival was 25% at 5 yr and 13% at 10 yr. Most of the patients eventually succumbed to metastatic breast carcinoma and the actuarial survival at 5 yr was 43% and at 10 yr, 16%. The addition of adjuvant low-dose chemotherapy, given to 13 patients, did not affect the rates of local control, survival or disease-free survival. The most common long-term complication was extensive and deforming radiation-induced fibrosis of the treated breast. The actuarial probability of 10-yr survival without a local recurrence and without severe fibrosis of the treated breast was only 17.5%. The role of adjuvant high-dose chemotherapy in the treatment of locally advanced breast carcinoma and the possible use of improved radiotherapy techniques to achieve a more effective long-term local control and a more desirable cosmetic end result are discussed. (author)

  14. Hypofractionated Proton Boost Combined with External Beam Radiotherapy for Treatment of Localized Prostate Cancer

    Science.gov (United States)

    Johansson, Silvia; Åström, Lennart; Sandin, Fredrik; Isacsson, Ulf; Montelius, Anders; Turesson, Ingela

    2012-01-01

    Proton boost of 20 Gy in daily 5 Gy fractions followed by external beam radiotherapy (EBRT) of 50 Gy in daily 2 Gy fractions were given to 278 patients with prostate cancer with T1b to T4N0M0 disease. Fifty-three percent of the patients received neoadjuvant androgen deprivation therapy (N-ADT). The medium followup was 57 months. The 5-year PSA progression-free survival was 100%, 95%, and 74% for low-, intermediate-, and high-risk patients, respectively. The toxicity evaluation was supported by a patient-reported questionnaire before every consultant visit. Cumulative probability and actuarial prevalence of genitourinary (GU) and gastrointestinal (GI) toxicities are presented according to the RTOG classification. N-ADT did not influence curability. Mild pretreatment GU-symptoms were found to be a strong predictive factor for GU-toxicity attributable to treatment. The actuarial prevalence declined over 3 to 5 years for both GU and GI toxicities, indicating slow resolution of epithelial damage to the genitourinary and gastrointestinal tract. Bladder toxicities rather than gastrointestinal toxicities seem to be dose limiting. More than 5-year followup is necessary to reveal any sign of true progressive late side effects of the given treatment. Hypofractionated proton-boost combined with EBRT is associated with excellent curability of localized PC and acceptable frequencies of treatment toxicity. PMID:22848840

  15. PSA bounces after neoadjuvant androgen deprivation and external beam radiation: Impact on definitions of failure

    International Nuclear Information System (INIS)

    Zietman, Anthony L.; Christodouleas, John P.; Shipley, William U.

    2005-01-01

    Purpose: To determine the characteristics of prostate specific antigen (PSA) bounces after external beam radiation therapy (EBRT) with neoadjuvant androgen deprivation and their impact on definitions of biochemical failure. Methods and Materials: Characteristics of bounce were calculated for all patients treated by EBRT with neoadjuvant androgen deprivation at our institution between 1992 and 1998 (preexclusion analysis). Calculations were repeated for the subgroup that satisfied additional inclusion/exclusion criteria (postexclusion analysis). The percentage of bounces scoring as false positives according to the ASTRO definition of biochemical failure was compared with those for three alternative definitions (Vancouver, Nadir-plus-two, and Nadir-plus-three) using McNemar's tests. Results: Thirty-nine percent (preexclusion cohort) and 56% (postexclusion cohort) of patients demonstrated a PSA bounce. Twenty percent (preexclusion analysis) and 25% (postexclusion analysis) of these bounces scored as biochemical failure according to the ASTRO definition. The Nadir-plus-three definition scored the smallest percentage of bounces as failure, but the difference between this definition and the ASTRO definition reached statistical significance in neither preexclusion nor postexclusion analyses (p ≥ 0.070). Conclusions: A substantial proportion of patients treated by EBRT with neoadjuvant deprivation experienced a PSA bounce. A large percentage of these bounces scored as biochemical failure according to the ASTRO definition. The Nadir-plus-three definition is less vulnerable to this bias

  16. A Preliminary Design Of Application Of Wireless Identification And Sensing Platform On External Beam Radiotherapy

    Science.gov (United States)

    Heranudin; Bakhri, S.

    2018-02-01

    A linear accelerator (linac) is widely used as a means of radiotherapy by focusing high-energy photons in the targeted tumor of patient. Incorrectness of the shooting can lead normal tissue surrounding the tumor received unnecessary radiation and become damaged cells. A method is required to minimize the incorrectness that mostly caused by movement of the patient during radiotherapy process. In this paper, the Wireless Identification and Sensing Platform (WISP) architecture was employed to monitor in real time the movement of the patient’s body during radiotherapy process. In general, the WISP is a wearable sensors device that can transmit measurement data wirelessly. In this design, the measurement devices consist of an accelerometer, a barometer and an ionizing radiation sensor. If any changes in the body position which resulted in incorrectness of the shooting, the accelerometer and the barometer will trigger a warning to the linac operator. In addition, the radiation sensor in the WISP will detect unwanted radiation and that can endanger the patient. A wireless feature in this device can ease in implementation. Initial analyses have been performed and showed that the WISP is feasible to be applied on external beam radiotherapy.

  17. The role of adjuvant external beam radiation therapy for papillary thyroid carcinoma invading the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk; Choi, Jae Hyuck; Kim, Kwang Sik [Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); and others

    2017-06-15

    To evaluate the effect of adjuvant external beam radiation therapy (EBRT) on local failure-free survival rate (LFFS) for papillary thyroid cancer (PTC) invading the trachea. Fifty-six patients with locally advanced PTC invading the trachea were treated with surgical resection. After surgery, 21 patients received adjuvant EBRT and radioactive iodine therapy (EBRT group) and 35 patients were treated with radioactive iodine therapy (control group). The age range was 26–87 years (median, 56 years). The median follow-up period was 43 months (range, 4 to 145 months). EBRT doses ranged from 50.4 to 66 Gy (median, 60 Gy). Esophagus invasion and gross residual disease was more frequent in the EBRT group. In the control group, local recurrence developed in 9 (9/35, 26%) and new distant metastasis in 2 (2/35, 6%) patients, occurring 4 to 68 months (median, 37 months) and 53 to 68 months (median, 60 months) after surgery, respectively. Two patients had simultaneous local recurrence and new distant metastasis. There was one local failure in the EBRT group at 18 months after surgery (1/21, 5%). The 5-year LFFS was 95% in the EBRT group and 63% in the control group (p = 0.103). In the EBRT group, one late grade 2 xerostomia was developed. Although, EBRT group had a higher incidence of esophagus invasion and gross residual disease, EBRT group showed a better 5-year LFFS. Adjuvant EBRT may have contributed to the better LFFS in these patients.

  18. Hypofractionated Proton Boost Combined with External Beam Radiotherapy for Treatment of Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Silvia Johansson

    2012-01-01

    Full Text Available Proton boost of 20 Gy in daily 5 Gy fractions followed by external beam radiotherapy (EBRT of 50 Gy in daily 2 Gy fractions were given to 278 patients with prostate cancer with T1b to T4N0M0 disease. Fifty-three percent of the patients received neoadjuvant androgen deprivation therapy (N-ADT. The medium followup was 57 months. The 5-year PSA progression-free survival was 100%, 95%, and 74% for low-, intermediate-, and high-risk patients, respectively. The toxicity evaluation was supported by a patient-reported questionnaire before every consultant visit. Cumulative probability and actuarial prevalence of genitourinary (GU and gastrointestinal (GI toxicities are presented according to the RTOG classification. N-ADT did not influence curability. Mild pretreatment GU-symptoms were found to be a strong predictive factor for GU-toxicity attributable to treatment. The actuarial prevalence declined over 3 to 5 years for both GU and GI toxicities, indicating slow resolution of epithelial damage to the genitourinary and gastrointestinal tract. Bladder toxicities rather than gastrointestinal toxicities seem to be dose limiting. More than 5-year followup is necessary to reveal any sign of true progressive late side effects of the given treatment. Hypofractionated proton-boost combined with EBRT is associated with excellent curability of localized PC and acceptable frequencies of treatment toxicity.

  19. Fractionated external beam radiotherapy of skull base metastases with cranial nerve involvement

    Energy Technology Data Exchange (ETDEWEB)

    Droege, L.H.; Hinsche, T.; Hess, C.F.; Wolff, H.A. [University Hospital of Goettingen, Department of Radiotherapy and Radiation Oncology, Goettingen (Germany); Canis, M. [University of Goettingen, Department of Otorhinolaryngology, Head and Neck Surgery, Goettingen (Germany); Alt-Epping, B. [University of Goettingen, Department of Palliative Medicine, Goettingen (Germany)

    2014-02-15

    Skull base metastases frequently appear in a late stage of various tumor entities and cause pain and neurological disorders which strongly impair patient quality of life. This study retrospectively analyzed fractionated external beam radiotherapy (EBRT) as a palliative treatment approach with special respect to neurological outcome, feasibility and acute toxicity. A total of 30 patients with skull base metastases and cranial nerve disorders underwent EBRT with a mean total dose of 31.6 Gy. Neurological status was assessed before radiotherapy, during radiotherapy and 2 weeks afterwards categorizing orbital, parasellar, middle fossa, jugular foramen and occipital condyle involvement and associated clinical syndromes. Neurological outcome was scored as persistence of symptoms, partial response, good response and complete remission. Treatment-related toxicity and overall survival were assessed. Before EBRT 37 skull base involvement syndromes were determined with 4 patients showing more than 1 syndrome. Of the patients 81.1 % responded to radiotherapy with 10.8 % in complete remission, 48.6 % with good response and 21.6 % with partial response. Grade 1 toxicity of the skin occurred in two patients and grade 1 hematological toxicity in 1 patient under concurrent chemoradiotherapy. Median overall survival was 3.9 months with a median follow-up of 45 months. The use of EBRT for skull base metastases with symptomatic involvement of cranial nerves is marked by good therapeutic success in terms of neurological outcome, high feasibility and low toxicity rates. These findings underline EBRT as the standard therapeutic approach in the palliative setting. (orig.)

  20. Treatment of prostate cancer using external beam radiotherapy after laparoscopic pelvic lymph node dissection

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, G.S.; Bales, G.T.; Gornik, H.L.; Haraf, D.J.; Chodak, G.W.; Rukstalis, D.B. [Chicago Univ., IL (United States). Pritzker School of Medicine

    1996-06-01

    The objectives were to evaluate the results of prostatic irradiation in men with clinically localized prostate cancer and no laparoscopic evidence of nodal metastates compared with a cohort of patients who received radiation therapy with no prior surgical staging. Radiation therapy was generally well tolerated after laparoscopy and no patient required hospitalization or surgery for side-effects related to the treatment. The median duration of follow-up in the 31 men who underwent laparoscopy was 21.5 months. The probability of treatment failure in this group was 41.8% and 56.3% with 24 and 30 months follow-up, respectively. When controlling for pre-treatment PSA level, grade and stage, there was no significant difference in the treatment failure rate between the groups treated with and without laparoscopic staging. These results suggest that there is no difference in treatment outcome with laparoscopic pelvic lymphadenectomy before external beam radiation therapy in high-risk patients who have significant pretreatment elevations of PSA level. (Author).

  1. An implantable radiation dosimeter for use in external beam radiation therapy

    International Nuclear Information System (INIS)

    Scarantino, Charles W.; Ruslander, David M.; Rini, Christopher J.; Mann, Gregory G.; Nagle, H. Troy; Black, Robert D.

    2004-01-01

    An implantable radiation dosimeter for use with external beam therapy has been developed and tested both in vitro and in canines. The device uses a MOSFET dosimeter and is polled telemetrically every day during the course of therapy. The device is designed for permanent implantation and also acts as a radiographic fiducial marker. Ten dogs (companion animals) that presented with spontaneous, malignant tumors were enrolled in the study and received an implant in the tumor CTV. Three dogs received an additional implant in collateral normal tissue. Radiation therapy plans were created for the animals and they were treated with roughly 300 cGy daily fractions until completion of the prescribed cumulative dose. The primary endpoints of the study were to record any adverse events due to sensor placement and to monitor any movement away from the point of placement. No adverse events were recorded. Unacceptable device migration was experienced in two subjects and a retention mechanism was developed to prevent movement in the future. Daily dose readings were successfully acquired in all subjects. A rigorous in vitro calibration methodology has been developed to ensure that the implanted devices maintain an accuracy of ±3.5% relative to an ionization chamber standard. The authors believe that an implantable radiation dosimeter is a practical and powerful tool that fosters individualized patient QA on a daily basis

  2. PSA bounce phenomenon after External Beam Radiation Therapy for prostate cancer

    International Nuclear Information System (INIS)

    Roszkowski, K.; Makarewicz, R.

    2007-01-01

    Introduction to clinical practice of PSA antigen altered the therapeutic approach to treatment of prostate cancer. The PSA antigen was defined as sensitive marker for monitoring of prostate cancer. At treated with radiotherapy patients (EBRT) value of PSA nadir after treatment is the significant determinant of results of treatment statistically. Three consecutive PSA rise above the post-treatment nadir have been defined as biochemical failure by the American Society for Therapeutic Radiology and Oncology (ASTRO) consensus panel. However a single rise in post-EBRT PSA level continues to be a source of considerable anxiety due to the intriguing uncertainty of relationship between PSA bouncing and disease relapse. The clinical practice show that growth of level PSA after radiotherapy was possible and does not it join with progression of disease. Phenomenon this was named as PSA-bounce. Various definitions of PSA bounce have been used in the literature. The authors in presented work represent the current state of knowledge on this phenomenon after use radical External Beam Radiation Therapy. (authors)

  3. Perspectives in absorbed dose metrology with regard to the technical evolutions of external beam radiotherapy

    International Nuclear Information System (INIS)

    Chauvenet, B.; Bordy, J.M.; Barthe, J.

    2009-01-01

    This paper presents several R and D axes in absorbed close metrology to meet the needs resulting from the technical evolutions of external beam radiotherapy. The facilities in operation in France have considerably evolved under the impulse of the plan Cancer launched in 2003: replacements and increase of the number of accelerators, substitution of accelerators for telecobalt almost completed and acquisition of innovative facilities for tomo-therapy and stereotaxy. The increasing versatility of facilities makes possible the rapid evolution of treatment modalities, allowing to better delimit irradiation to tumoral tissues and spare surrounding healthy tissues and organs at risk. This leads to a better treatment efficacy through dose escalation. National metrology laboratories must offer responses adapted to the new need, i.e. not restrict themselves to the establishment of references under conventional conditions defined at international level, contribute to the improvement of uncertainties at all levels of reference transfer to practitioners: primary measurements under conditions as close as possible to those of treatment, characterization of transfer and treatment control dosimeters., metrological validation of treatment planning tools... Those axes have been identified as priorities for the next years in ionizing radiation metrology at the European level and included in the European. Metrology Research Programme. A project dealing with some of those topics has been selected in the frame of the Eranet+ Call EMRP 2007 and is now starting. The LNE-LAM is strongly engaged in it. (authors)

  4. Fractionated external beam radiotherapy of skull base metastases with cranial nerve involvement

    International Nuclear Information System (INIS)

    Droege, L.H.; Hinsche, T.; Hess, C.F.; Wolff, H.A.; Canis, M.; Alt-Epping, B.

    2014-01-01

    Skull base metastases frequently appear in a late stage of various tumor entities and cause pain and neurological disorders which strongly impair patient quality of life. This study retrospectively analyzed fractionated external beam radiotherapy (EBRT) as a palliative treatment approach with special respect to neurological outcome, feasibility and acute toxicity. A total of 30 patients with skull base metastases and cranial nerve disorders underwent EBRT with a mean total dose of 31.6 Gy. Neurological status was assessed before radiotherapy, during radiotherapy and 2 weeks afterwards categorizing orbital, parasellar, middle fossa, jugular foramen and occipital condyle involvement and associated clinical syndromes. Neurological outcome was scored as persistence of symptoms, partial response, good response and complete remission. Treatment-related toxicity and overall survival were assessed. Before EBRT 37 skull base involvement syndromes were determined with 4 patients showing more than 1 syndrome. Of the patients 81.1 % responded to radiotherapy with 10.8 % in complete remission, 48.6 % with good response and 21.6 % with partial response. Grade 1 toxicity of the skin occurred in two patients and grade 1 hematological toxicity in 1 patient under concurrent chemoradiotherapy. Median overall survival was 3.9 months with a median follow-up of 45 months. The use of EBRT for skull base metastases with symptomatic involvement of cranial nerves is marked by good therapeutic success in terms of neurological outcome, high feasibility and low toxicity rates. These findings underline EBRT as the standard therapeutic approach in the palliative setting. (orig.)

  5. Optimising measles virus-guided radiovirotherapy with external beam radiotherapy and specific checkpoint kinase 1 inhibition

    International Nuclear Information System (INIS)

    Touchefeu, Yann; Khan, Aadil A.; Borst, Gerben; Zaidi, Shane H.; McLaughlin, Martin; Roulstone, Victoria; Mansfield, David; Kyula, Joan; Pencavel, Tim; Karapanagiotou, Eleni M.; Clayton, Jamie; Federspiel, Mark J.; Russell, Steve J.; Garrett, Michelle; Collins, Ian; Harrington, Kevin J.

    2013-01-01

    Background and purpose: We previously reported a therapeutic strategy comprising replication-defective NIS-expressing adenovirus combined with radioiodide, external beam radiotherapy (EBRT) and DNA repair inhibition. We have now evaluated NIS-expressing oncolytic measles virus (MV-NIS) combined with NIS-guided radioiodide, EBRT and specific checkpoint kinase 1 (Chk1) inhibition in head and neck and colorectal models. Materials and methods: Anti-proliferative/cytotoxic effects of individual agents and their combinations were measured by MTS, clonogenic and Western analysis. Viral gene expression was measured by radioisotope uptake and replication by one-step growth curves. Potential synergistic interactions were tested in vitro by Bliss independence analysis and in in vivo therapeutic studies. Results: EBRT and MV-NIS were synergistic in vitro. Furthermore, EBRT increased NIS expression in infected cells. SAR-020106 was synergistic with EBRT, but also with MV-NIS in HN5 cells. MV-NIS mediated 131 I-induced cytotoxicity in HN5 and HCT116 cells and, in the latter, this was enhanced by SAR-020106. In vivo studies confirmed that MV-NIS, EBRT and Chk1 inhibition were effective in HCT116 xenografts. The quadruplet regimen of MV-NIS, virally-directed 131 I, EBRT and SAR-020106 had significant anti-tumour activity in HCT116 xenografts. Conclusion: This study strongly supports translational and clinical research on MV-NIS combined with radiation therapy and radiosensitising agents

  6. In-vivo dosimetric study of carcinoma of uterine cervix with FBX solution in external beam therapy

    International Nuclear Information System (INIS)

    Srinivas, Challapalli; Shenoy, K. Kamalaksh; Dinesh, M.; Savitha, K.S.; Kasturi, Dinesh Pai; Supe, S.S.; Nagesha, Y.N.

    1999-01-01

    To ensure accurate dose delivery to target site in external beam therapy and brachytherapy, various authors have conducted tests to assess the process of manual dose calculations. In vivo dosimetric measurement is one of these methods to verify these calculations. In this study, an attempt has been made to compare the manually calculated dose to dose estimated using a chemical dosimeter (FBX) solution (in-vivo method, using polypropylene vials), on 12 patients of carcinoma of uterine cervix in external beam therapy. Dose measured by FBX vial varies in the range of ± 2 to 6.75%, as compared with manual calculations. These variations seen may be attributed to the location of the vial position in the vagina, with reference to the beam axis (may not be horizontal), off axis position, manual calculation variations and reproducibility of the FBX system etc. FBX dosimetry offers itself as an in-vivo method to estimate the dose delivered to the target site in external beam therapy. (author)

  7. Endodontic management of a maxillary lateral incisor with dens invaginatus and external root irregularity using cone-beam computed tomography

    Directory of Open Access Journals (Sweden)

    Young-Jun Lim

    2012-02-01

    Full Text Available Cone-beam computed tomography (CBCT is a useful diagnostic tool for identification of both internal and external root configurations. This case report describes the endodontic management of a lateral incisor with both dens invaginatus and external root irregularity by using CBCT. Nonsurgical endodontic retreatment was performed on the lateral incisor with dens invaginatus. A perforation through the dens invaginatus and external concavity was repaired using mineral trioxide aggregate. After 18 mon of follow-up, there were no clinical symptoms. Recall radiographs appeared normal and showed healing of the periapical pathosis. The understanding of both internal root canal configuration and external root irregularity using CBCT can ensure predictable and successful results.

  8. Development of silicon monolithic arrays for dosimetry in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bisello, Francesca, E-mail: francesca.bisello@iba-group.com [IBA Dosimetry GmbH, Schwarzenbruck (Germany); Friedrich-Alexander Universität Erlangen—Nürnberg, Erlangen (Germany); Menichelli, David [IBA Dosimetry GmbH, Schwarzenbruck (Germany); Scaringella, Monica [University of Florence, Firenze (Italy); INFN—Florence Division, Sesto Fiorentino (Italy); Talamonti, Cinzia; Zani, Margherita; Bucciolini, Marta [University of Florence, Firenze (Italy); Azienda Ospedaliera Unversitaria Careggi, Firenze (Italy); Bruzzi, Mara [University of Florence, Firenze (Italy); INFN—Florence Division, Sesto Fiorentino (Italy)

    2015-10-01

    New tools for dosimetry in external beam radiotherapy have been developed during last years in the framework of the collaboration among the University of Florence, INFN Florence and IBA Dosimetry. The first step (in 2007) was the introduction in dosimetry of detector solutions adopted from high energy physics, namely epitaxial silicon as the base detector material and a guard ring in diode design. This allowed obtaining state of the art radiation hardness, in terms of sensitivity dependence on accumulated dose, with sensor geometry particularly suitable for the production of monolithic arrays with modular design. Following this study, a 2D monolithic array has been developed, based on 6.3×6.3 cm{sup 2} modules with 3 mm pixel pitch. This prototype has been widely investigated and turned out to be a promising tool to measure dose distributions of small and IMRT fields. A further linear array prototype has been recently design with improve spatial resolution (1 mm pitch) and radiation hardness. This 24 cm long device is constituted by 4×64 mm long modules. It features low sensitivity changes with dose (0.2%/kGy) and dose per pulse (±1% in the range 0.1–2.3 mGy/pulse, covering applications with flattened and unflattened photon fields). The detector has been tested with very satisfactory results as a tool for quality assurance of linear accelerators, with special regards to small fields, and proton pencil beams. In this contribution, the characterization of the linear array with unflattened MV X-rays, {sup 60}Co radiation and 226 MeV protons is reported. - Highlights: • A silicon monolithic 1D array with 1 mm pixel pitch was developed. • The detector was characterized with {sup 60}Co, unflattened MV X-rays, 226 MeV protons. • Dose linearity in clinical relevance range and dose profiles were measured. • The detector performs good agreement with reference detectors. • The technology is suitable in dose profiling in MV X-ray and proton therapy.

  9. A simple technique for treating age-related macular degeneration with external beam radiotherapy

    International Nuclear Information System (INIS)

    Roos, Daniel E.; Francis, J. Winston; Newnham, W. John

    1999-01-01

    Purpose: To develop a simple external beam photon radiotherapy technique to treat age-related macular degeneration without the need for simulation, planning computed tomography (CT) or computer dosimetry. Methods and Materials: The goal was to enable the treatment to be set up reliably on the treatment machine on Day 1 with the patient supine in a head cast without any prior planning. Using measurements of ocular globe topography from Karlsson et al. (Int J Radiat Oncol Biol Phys 1996; 33: 705-712), we chose a point 1.5 cm behind the anterior surface of the upper eyelid (ASUE) as the isocentre of a half-beam, blocked, 5.0 x 3.0-cm, angled lateral field to treat the involved eye. This would position the isocentre about 0.5 cm behind the posterior surface of the lens, and a little over 1 cm in front of the macula, according to Karlsson et al. The setup requires initial adjustment of the gantry from horizontal (to account for any asymmetry of position of the eyes), then angling 15 deg. posteriorly to avoid the contralateral eye. Finally, the couch is raised to position the isocentre 1.5 cm behind the ASUE. Results: To verify the applicability of the technique, we performed CT and computer dosimetry on the first 11 eyes so treated. Our CT measurements were in good agreement with Karlsson et al. The lens dose was < 5% and the macula was within the 95% isodose curve in each case (6-MV linac). Treatment setup time is approximately 10 min each day. The 11 patients were treated with 5 x 2.00 Gy (2 patients) or 5 x 3.00 Gy (9 patients), and subjective response on follow-up over 1 to 12 months (median 4 months) was comparable to previously reported results, with no significant acute side effects. Conclusion: Our technique is easy to set up and reliably treats the macula, with sparing of the lens and contralateral eye. It enables treatment to commence rapidly and cost-effectively without the need for simulation or CT computer planning

  10. Integration of XRF spectrometer for simultaneous and/or complementary use with PIXE at the external ion beam analysis setup

    Energy Technology Data Exchange (ETDEWEB)

    Fazinic, S.; Cosic, D.; Jaksic, M. [Laboratory for lon Beam Interactions, Division of Experimental Physics, Rudjer Boskovic Institute, Zagreb (Croatia); Migliori, A.; Karydas, A.G. [Nuclear Spectrometry and Applications Laboratory, International Atomic Energy Agency (IAEA), Vienna (Austria); Desnica, V. [Laboratory for Science and Technology in Art, Academy of Fine Arts in Zagreb, Zagreb (Croatia); Mudronja, D. [Natural Science Laboratory, Croatian Conservation Institute, Zagreb (Croatia)

    2013-07-01

    Full text: The Rudjer Boskovic Institute Tandem Accelerator Facility is equipped with a number of end-stations dedicated to ion beam analysis (IBA), modification of materials and nuclear physics experiments. IBA is performed at the: (1) nuclear microbeam, (2) broad-beam in-vacuum and (3) external beam end-stations. Several lBA techniques can be used simultaneously, Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma-ray Emission (PIGE) at the external beam end-station, and additionally Rutherford Backscattering Spectroscopy (RBS) at the in-vacuum end-station. X-ray fluorescence (XRF) analysis is a technique complementary to PIXE. Both techniques offer high analytical potential for multi-elemental investigations and material characterization. Due to different excitation mechanisms, PIXE generally exhibits higher sensitivity for lighter elements and XRF for heavier, whereas they also have different in-sample depth sensitivities. Although they use different excitation sources, both techniques can use the same data acquisition modules. With the development of miniature, low power and lightweight X-ray tubes it is possible to incorporate an X-ray source within the IBA setup and combine the two techniques for simultaneous use. In this work, the unification of the PIXE and XRF techniques at the RBI external ion beam analysis setup has been investigated and the results are discussed. This has been done by installing a transmission miniature X-ray tube at the end-station. The tube has been properly positioned in order to irradiate the same spot on the sample as the ion beam used for PIXE/PIGE measurements. Our home made data acquisition system SPECTOR, used regularly for the IBA measurements, has been also used to acquire the XRF spectra. At first, the X-ray tube has been installed at the in-vacuum IBA station, and then to the external beam end-station. Test measurements have been carried out on various standard reference materials using both systems and the

  11. Can multiparametric MRI replace Roach equations in staging prostate cancer before external beam radiation therapy?

    Energy Technology Data Exchange (ETDEWEB)

    Girometti, Rossano, E-mail: rgirometti@sirm.org [Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, University of Udine, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia − via Colugna, 50–33100, Udine (Italy); Signor, Marco Andrea, E-mail: marco.signor@asuiud.sanita.fvg.it [Department of Oncological Radiation Therapy, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia, Piazzale S. M. della Misericordia, 15–33100, Udine (Italy); Pancot, Martina, E-mail: martypancot@libero.it [Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, University of Udine, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia − via Colugna, 50–33100, Udine (Italy); Cereser, Lorenzo, E-mail: lcereser@sirm.org [Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, University of Udine, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia − via Colugna, 50–33100, Udine (Italy); Zuiani, Chiara, E-mail: chiara.zuiani@uniud.it [Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, University of Udine, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia − via Colugna, 50–33100, Udine (Italy)

    2016-12-15

    Purpose: To investigate the agreement between Roach equations (RE) and multiparametric magnetic resonance imaging (mpMRI) in assessing the T-stage of prostate cancer (PCa). Materials and methods: Seventy-three patients with biopsy-proven PCa and previous RE assessment prospectively underwent mpMRI on a 3.0T magnet before external beam radiation therapy (EBRT). Using Cohen’s kappa statistic, we assessed the agreement between RE and mpMRI in defining the T-stage (≥T3 vs.T ≤ 2) and risk category according to the National comprehensive cancer network criteria (≤intermediate vs. ≥high). We also calculated sensitivity and specificity for ≥T3 stage in an additional group of thirty-seven patients with post-prostatectomy histological examination (mpMRI validation group). Results: The agreement between RE and mpMRI in assessing the T stage and risk category was moderate (k = 0.53 and 0.56, respectively). mpMRI changed the T stage and risk category in 21.9% (95%C.I. 13.4–33-4) and 20.5% (95%C.I. 12.3–31.9), respectively, prevalently downstaging PCa compared to RE. Sensitivity and specificity for ≥T3 stage in the mpMRI validation group were 81.8% (95%C.I. 65.1–91.9) and 88.5% (72.8–96.1). Conclusion: RE and mpMRI show moderate agreement only in assessing the T-stage of PCa, translating into an mpMRI-induced change in risk assessment in about one fifth of patients. As supported by high sensitivity/specificity for ≥T3 stage in the validation group, the discrepancy we found is in favour of mpMRI as a tool to stage PCa before ERBT.

  12. Radical prostatectomy versus external beam radiotherapy for localized prostate cancer. Comparison of treatment outcomes

    International Nuclear Information System (INIS)

    Kim, Yeon-Joo; Cho, Kwan Ho; Lee, Kang Hyun; Moon, Sung Ho; Kim, Tae Hyun; Shin, Kyung Hwan; Kim, Joo-Young; Kim, Young-kyung; Lee, Se Byeong; Pyo, Hong Ryull

    2015-01-01

    We retrospectively compared the treatment outcomes of localized prostate cancer between radical prostatectomy (RP) and external beam radiotherapy (EBRT). We retrospectively analyzed 738 patients with localized prostate cancer who underwent either RP (n = 549) or EBRT (n = 189) with curative intent at our institution between March 2001 and December 2011. Biochemical failure was defined as a prostate-specific antigen (PSA) level of ≥ 0.2 ng/ml in the RP group and the nadir of + ≥ 2 ng/ml in the EBRT group. The median (range) follow-up duration was 48.8 months (0.7-133.2 months) and 48.7 months (1.0-134.8 months) and the median age was 66 years (45-89 years) and 71 years (51-84 years; p < 0.001) in the RP and EBRT groups, respectively. Overall, 21, 42, and 36 % of patients in the RP group, and 15, 27, and 58 % of patients in the EBRT group were classified as low, intermediate, and high risk, respectively (p < 0.001). Androgen-deprivation therapy was more common in the EBRT group (59 vs. 27 %, respectively; p < 0.001). The 8-year biochemical failure-free survival rates were 44 and 72 % (p < 0.001) and the disease-specific survival rates were 98 % and 97 % (p = 0.543) in the RP and EBRT groups, respectively. Although the EBRT group included more high-risk patients than did the RP group, the outcomes of EBRT were not inferior to those of RP. Our data suggest that EBRT is a viable alternative to RP for treating localized prostate cancer. (orig.) [de

  13. Targeted Intraoperative Radiotherapy for Breast Cancer in Patients in Whom External Beam Radiation Is Not Possible

    International Nuclear Information System (INIS)

    Keshtgar, Mohammed R.S.; Vaidya, Jayant S.; Tobias, Jeffrey S.; Wenz, Frederik; Joseph, David; Stacey, Chris; Metaxas, Marinos G.; Keller, Anke; Corica, Tammy; Williams, Norman R.; Baum, Michael

    2011-01-01

    Purpose: External beam radiation therapy (EBRT) following wide local excision of the primary tumor is the standard treatment in early breast cancer. In some circumstances this procedure is not possible or is contraindicated or difficult. The purpose of this study was to determine the safety and efficacy of targeted intraoperative radiotherapy (TARGIT) when EBRT is not feasible. Methods and Materials: We report our experience with TARGIT in three centers (Australia, Germany, and the United Kingdom) between 1999 and 2008. Patients at these centers received a single radiation dose of 20 Gy to the breast tissue in contact with the applicator (or 6 Gy at 1-cm distance), as they could not be given EBRT and were keen to avoid mastectomy. Results: Eighty patients were treated with TARGIT. Reasons for using TARGIT were 21 patients had previously received EBRT, and 31 patients had clinical reasons such as systemic lupus erythematosus, motor neuron disease, Parkinson's disease, ankylosing spondylitis, morbid obesity, and cardiovascular or severe respiratory disease. Three of these patients received percutaneous radiotherapy without surgery; 28 patients were included for compelling personal reasons, usually on compassionate grounds. After a median follow-up of 38 months, only two local recurrences were observed, an annual local recurrence rate of 0.75% (95% confidence interval, 0.09%-2.70%). Conclusions: While we await the results of the randomized trial (over 2,000 patients have already been recruited), TARGIT is an acceptable option but only in highly selected cases that cannot be recruited in the trial and in whom EBRT is not feasible/possible.

  14. Unified registration framework for cumulative dose assessment in cervical cancer across external beam radiotherapy and brachytherapy

    Science.gov (United States)

    Roy, Sharmili; Totman, John J.; Choo, Bok A.

    2016-03-01

    Dose accumulation across External Beam Radiotherapy (EBRT) and Brachytherapy (BT) treatment fractions in cervical cancer is extremely challenging due to structural dissimilarities and large inter-fractional anatomic deformations between the EBRT and BT images. The brachytherapy applicator and the bladder balloon, present only in the BT images, introduce missing structural correspondences for the underlying registration problem. Complex anatomical deformations caused by the applicator and the balloon, different rectum and bladder filling and tumor shrinkage compound the registration difficulties. Conventional free-form registration methods struggle to handle such topological differences. In this paper, we propose a registration pipeline that first transforms the original images to their distance maps based on segmentations of critical organs and then performs non-linear registration of the distance maps. The resulting dense deformation field is then used to transform the original anatomical image. The registration accuracy is evaluated on 27 image pairs from stage 2B-4A cervical cancer patients. The algorithm reaches a Hausdorff distance of close to 0:5 mm for the uterus, 2:2 mm for the bladder and 1:7 mm for the rectum when applied to (EBRT,BT) pairs, taken at time points more than three months apart. This generalized model-free framework can be used to register any combination of EBRT and BT images as opposed to methods in the literature that are tuned for either only (BT,BT) pair, or only (EBRT,EBRT) pair or only (BT,EBRT) pair. A unified framework for 3D dose accumulation across multiple EBRT and BT fractions is proposed to facilitate adaptive personalized radiation therapy.

  15. External beam irradiation of craniopharyngiomas: long-term analysis of tumor control and morbidity

    International Nuclear Information System (INIS)

    Varlotto, John M.; Flickinger, John C.; Kondziolka, Douglas; Lunsford, L.D.; Deutsch, Melvin

    2002-01-01

    Purpose: To delineate the long-term control and morbidity with external beam radiotherapy (EBRT) of craniopharyngiomas. Methods and Materials: Between 1971 and 1992, 24 craniopharyngioma patients underwent EBRT at the University of Pittsburgh. Most (19 of 24) were treated within 1-3 months after subtotal resection. The other prior surgical procedures were biopsy (n = 2) and gross total resection (n = 1); 2 patients did not undergo any surgical procedure. The median follow-up was 12.1 years. The median patient age was 29 years (range 5-69). The total radiation doses varied from 36 to 70 Gy (median 59.75). The normalized total dose (NTD, biologically equivalent dose given in 2 Gy/fraction [α/β ratio = 2]) varied from 28 to 83 Gy (median 55.35). Results: The actuarial survival rate at 10 and 20 years was 100% and 92.3%, respectively. The actuarial local control rate at 10 and 20 years was 89.1% and 54.0%, respectively. No local failures occurred with doses ≥60 Gy (n=12) or NTDs ≥55 Gy. The complication-free survival rate at 10 and 20 years was 80.1% and 72.1%, respectively. No complications were noted with an NTD of ≤55 Gy. The actuarial survival free from any adverse outcome (recurrence or complication) was 70.1% and 31.8% at 10 and 20 years, respectively. The adverse outcome-free survival appeared optimized (at 73%) with an NTD of 55-63 Gy. Multivariate analysis found that tumor control correlated significantly with the total dose (p=0.02), treatment complications with NTD (p=0.008), and adverse outcome with hypopituitarism on presentation (p=0.03). Conclusion: We recommend treating craniopharyngioma with 1.6-1.7-Gy dose fractions to 60 Gy to optimize outcome from EBRT

  16. External beam irradiation for retinoblastoma: patterns of failure and dose-response analysis

    International Nuclear Information System (INIS)

    Foote, R.L.; Garretson, B.R.; Schomberg, P.J.; Buskirk, S.J.; Robertson, D.M.; Earle, J.D.

    1989-01-01

    Eighteen children with retinoblastoma (25 eyes) were treated with external beam radiation at the Mayo Clinic between January 1977 and January 1987; 15 eyes were in groups I to III and 10 were in groups IV and V. The median number of tumors per eye was 3. Radiation therapy consisted of 4- or 6-MV photons. Doses varied from 39 to 51 Gy in 1.8- to 3.0-Gy fractions. Fourteen eyes were treated through lateral fields by anterior segment-sparing techniques, and 11 eyes were treated by an anterior approach with no attempt at anterior segment sparing. All patients survived (median follow-up, 31.5 months). Cataracts developed in five eyes at a median of 23 months, four in eyes treated with anterior segment-sparing techniques. Of the 15 group I to III eyes, 6 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation and 2 were enucleated. Of the 10 group IV and V eyes, 8 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation, 1 with persistent disease is being followed closely, and 3 were enucleated. Ten (71%) of the 14 eyes treated with anterior segment-sparing techniques required additional treatment. Four (36%) of the 11 eyes treated with an anterior approach required additional treatment. Ninety percent of the tumors 10 disc diameters or smaller (1 disc diameter = 1.6 mm) were controlled independently of dose and fractionation used when they were not in the low-dose area of the anterior retina of an eye treated with an anterior segment-sparing technique. We find that use of lateral, anterior segment-sparing techniques has a high risk of anterior retinal tumor development and cataract formation and should be abandoned in favor of techniques that treat the entire retina

  17. External beam irradiation for retinoblastoma: patterns of failure and dose-response analysis

    Energy Technology Data Exchange (ETDEWEB)

    Foote, R.L.; Garretson, B.R.; Schomberg, P.J.; Buskirk, S.J.; Robertson, D.M.; Earle, J.D.

    1989-03-01

    Eighteen children with retinoblastoma (25 eyes) were treated with external beam radiation at the Mayo Clinic between January 1977 and January 1987; 15 eyes were in groups I to III and 10 were in groups IV and V. The median number of tumors per eye was 3. Radiation therapy consisted of 4- or 6-MV photons. Doses varied from 39 to 51 Gy in 1.8- to 3.0-Gy fractions. Fourteen eyes were treated through lateral fields by anterior segment-sparing techniques, and 11 eyes were treated by an anterior approach with no attempt at anterior segment sparing. All patients survived (median follow-up, 31.5 months). Cataracts developed in five eyes at a median of 23 months, four in eyes treated with anterior segment-sparing techniques. Of the 15 group I to III eyes, 6 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation and 2 were enucleated. Of the 10 group IV and V eyes, 8 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation, 1 with persistent disease is being followed closely, and 3 were enucleated. Ten (71%) of the 14 eyes treated with anterior segment-sparing techniques required additional treatment. Four (36%) of the 11 eyes treated with an anterior approach required additional treatment. Ninety percent of the tumors 10 disc diameters or smaller (1 disc diameter = 1.6 mm) were controlled independently of dose and fractionation used when they were not in the low-dose area of the anterior retina of an eye treated with an anterior segment-sparing technique. We find that use of lateral, anterior segment-sparing techniques has a high risk of anterior retinal tumor development and cataract formation and should be abandoned in favor of techniques that treat the entire retina.

  18. Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer

    International Nuclear Information System (INIS)

    Bentel, Gunilla C.; Marks, Lawrence B.; Krishnamurthy, Rupa

    1997-01-01

    Purpose: To compare the setup accuracy during fractionated radiation therapy for two patient groups with lung cancer treated with and without an immobilization cradle. Methods: Three hundred ninety-seven port films from 30 patients immobilized in the Alpha Cradle TM1 were compared with 329 port films from 30 patients who were not immobilized with the cradle. All patients were treated with curative intent for nonmetastatic lung cancer. The frequency of physician-requested isocenter shifts were compared in the two groups using a two-tailed chi-square test. Initial port films taken on the first day of treatment, routine films taken usually weekly during radiation therapy, and requested films taken after a requested shift were considered separately. The immobilization device consisted of a custom-made foam cradle that extended from above the head to the knees. Patients were generally treated with their arms above their heads, and treatment setup marks in the immobilized patients were placed on both the patients' skin and the immobilization cradle. For the noncradle patients, setup marks were placed only on the patients' skin. Results: For the routine films, the frequency of physician-requested isocenter shifts was lower in immobilized patients than in the nonimmobilized group (p = 0.139). Most of this reduction was seen on oblique fields (p = 0.038). No benefits were seen among initial or requested films. The two groups were well balanced with regard to stage, age, field size, and total dose. Conclusions: The use of aggressive immobilization improves the setup reproducibility in patients receiving external beam radiation therapy for lung cancer, especially during treatment with oblique fields. This improvement in treatment accuracy might improve the therapeutic ratio

  19. Combined external-beam PIXE and {mu}-Raman characterisation of garnets used in Merovingian jewellery

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: thomas.calligaro@culture.gouv.fr; Colinart, S.; Poirot, J.-P.; Sudres, C

    2002-04-01

    Red garnets were the dominant gemstones used for jewels in Europe during the Early Middle Ages. We have studied over 350 garnets set on 12 jewels unearthed in the royal necropolis of the Saint-Denis Basilica, close to Paris. This famous collection of 'cloisonne' style artefacts dates from the Merovingian period (late fifth century AD to early seventh century AD). The archaeological issue addressed is the identification of the geographical origin of these garnets, in view to establish the gem trading routes during the Dark Ages. External beam PIXE was used to determine the major constituents (Mg, Al, Si, Ca, Mn, Fe), specifying the garnet type (composition in various mineralogical end-members, e.g. almandine, pyrope, spessartite, ...), and the trace element content (Cr, Y). Three sorts of garnets were identified. Ten jewels are adorned with almandine garnets (Fe-rich). One jewel has intermediate almandine-pyrope garnets ('rhodolite'). The last and most recent jewel is inlaid with pyrope (Mg-rich) garnets. Trace element content and slight differences in major composition allowed to distinguish five different sources: two sources for pyrope garnets (with and without chromium), and two sources for almandine garnets (distinctive calcium, magnesium and yttrium contents). A preliminary comparison with literature data suggested that almandine garnets may have been mined from India while the 'rhodolite' garnets may have been imported from Sri Lanka. The sources of pyrope garnets could be the Bohemian deposits (Czech republic). In addition, {mu}-Raman spectrometry was used to identify most of the mineral inclusions (apatite, zircon, ilmenite, monazite, calcite, quartz) present in almandine garnets. Even if two specific types of inclusions were not identified, due to the lack of corresponding reference spectra in our database, the Raman spectra collected provided an interesting inclusion fingerprint.

  20. External beam radiation and high-dose-rate brachytherapy for elderly patients with gastroesophageal junction adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    2017-07-01

    Full Text Available Purpose: The aim of this study was to retrospectively observe and analyze the long-term treatment outcomes of 96 elderly patients with gastroesophageal junction adenocarcinoma (GEJAC who were treated with californium-252 (252Cf neutron brachytherapy (NBT in combination with external beam radiotherapy (EBRT with or without chemotherapy. Material and methods: From January 2002 to November 2012, 96 patients with GEJAC underwent treatment. The total radiation dose to the reference point via NBT was 8-25 Gy-eq in 2 to 5 fractions, with 1 fraction per week. The total dose via EBRT was 40-54 Gy, which was delivered over a period of 4 to 5.5 weeks with normal fraction. Results: The median survival time for the 96 patients was 15.3 months, and the 1-, 2-, 3-, and 5-year rates of overall survival (OS were 62.5%, 33.7%, 20.1%, and 7.9%, respectively. The 1-, 2-, 3-, and 5-year rates for local-regional control (LRC were 78.7%, 57.9%, 41.8%, and 26.4%, respectively. The patients’ age was an independent factor that was significantly associated with OS (p = 0.006 and LRC (p = 0.0005, according to univariate analysis. The 3-year OS (LRC was 31.9% (62.9% for patients aged 70-74 years and 16.1% (19.5% for patients aged ≥ 75 years. From the time of treatment completion to the development of local-regional recurrence or death, 5 (5.2% patients experienced fistula and 7 (7.3% experienced massive bleeding. Conclusions: The clinical data indicated that NBT in combination with EBRT produced favorable local control and long-term survival rates for elderly patients with GEJAC, and that the side effects were tolerable. The patient’s age could be used to select the appropriate treatment in an elderly patient.

  1. The international protocol for the dosimetry of external radiotherapy beams based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    Andreo, P.

    2001-01-01

    An International Code of Practice (CoP, or dosimetry protocol) for external beam radiotherapy dosimetry based on standards of absorbed dose to water has been published by the IAEA on behalf of IAEA, WHO, PAHO and ESTRO. The CoP provides a systematic and internationally unified approach for the determination of the absorbed dose to water in reference conditions with radiotherapy beams. The development of absorbed-dose-to-water standards for high-energy photons and electrons offers the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. Many laboratories already provide calibrations at the radiation quality of 60Co gamma-rays and some have extended calibrations to high-energy photon and electron beams. The dosimetry of kilovoltage x-rays, as well as that of proton and ion beams can also be based on these standards. Thus, a coherent dosimetry system based on the same formalism is achieved for practically all radiotherapy beams. The practical use of the CoP as simple. The document is formed by a set of different CoPs for each radiation type, which include detailed procedures and worksheets. All CoPs are based on ND,w chamber calibrations at a reference beam quality Qo, together with radiation beam quality correction factors kQ preferably measured directly for the user's chamber in a standards laboratory. Calculated values of kQ are provided together with their uncertainty estimates. Beam quality specifiers are 60Co, TPR20,10 (high-energy photons), R50 (electrons), HVL and kV (x-rays) and Rres (protons and ions) [es

  2. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation

    International Nuclear Information System (INIS)

    Brosed, A.; Delgado, A.; Granados, C. E.

    1987-01-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs

  3. Pain flare following external beam radiotherapy and meaningful change in pain scores in the treatment of bone metastases

    International Nuclear Information System (INIS)

    Chow, Edward; Ling, Alison; Davis, Lori; Panzarella, Tony; Danjoux, Cyril

    2005-01-01

    Background and purpose: To examine the incidence of pain flare following external beam radiotherapy and to determine what constitutes a meaningful change in pain scores in the treatment of bone metastases. Patients and methods: Patients with bone metastases treated with external beam radiotherapy were asked to score their pain on a scale of 0-10 before the treatment (baseline), daily during the treatment and for 10 days after completion of external beam radiation. Pain flare was defined as a two-point increase from baseline pain in the pain scale of 0-10 with no decrease in analgesic intake or a 25% increase in analgesic intake employing daily oral morphine equivalent with no decrease in pain score. To distinguish pain flare from progression of pain, we required the pain score and analgesic intake to return back to baseline levels after the increase/flare. They were also asked to indicate if their pain changed during that time compared to pre-treatment level. The change in pain score was compared with patient perception. Results: Eighty-eight patients were evaluated in this study. There were 49 male and 39 female patients with the median age of 70 years. Twelve of 88 patients (14%) had pain flare on day 1. The overall incidence of pain flare during the study period ranged from 2 to 16%. A total of 797 pain scorings were obtained. Patients perceived an improvement in pain when their self-reported pain score decreased by at least two points. Conclusions: Our study confirms the occurrence of pain flare following the external beam radiotherapy in the treatment of bone metastases. Further studies are required to predict who are at risk for flare. Appropriate measures can be taken to alleviate the pain flare. The finding in the meaningful change in pain scores supports the investigator-defined partial response used in some clinical trials

  4. MO-A-BRB-01: Review of TG-262 Internal Survey of Practices in EMR for External Beam Therapy

    International Nuclear Information System (INIS)

    Mechalakos, J.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  5. Primary carcinoma of the gallbladder: role of external beam radiation therapy in patients with locally advanced tumor

    International Nuclear Information System (INIS)

    Uno, T.; Itami, J.; Aruga, M.; Araki, H.; Tani, M.; Kobori, O.

    1996-01-01

    Several reports have demonstrated that occasional long-term survival might be obtained with external beam radiation therapy in patients with gallbladder cancer. However, there are few reports which evaluate the local effect of irradiation. The aim of our study was to investigate the local effect of radiation therapy and to evaluate its role for locally advanced gallbladder cancer. Twenty-two patients with locally advanced gallbladder cancer were treated with high-dose external beam radiation therapy. Tumor resection was performed in 5 patients, palliative surgery in 5, and the remaining 12 patients were treated by radiation therapy alone. Overall survival was 36% at 1 year, 18% at 3 years and 14% at 5 years. All but 2 patients developed undergone tumor resection, partial response was obtained in 4 patients and no response in 13. Survival times in patients who achieved partial response were 14, 26, 47 and 99 months, whereas those of no response were 1 to 12 months with a mean of 4.8 months. Survival between these 2 groups (partial vs. no response) showed significant difference (p=0.0008, logrank test). It is concluded that high-dose external beam radiation therapy could improve survival in some patients with unresectable gallbladder cancer. (orig.) [de

  6. Dose-volume histogram evaluation of prone and supine patient position in external beam radiotherapy for cervical and endometrial cancer

    International Nuclear Information System (INIS)

    Pinkawa, Michael; Gagel, Bernd; Demirel, Cengiz; Schmachtenberg, Axel; Asadpour, Branka; Eble, Michael J.

    2003-01-01

    Background and purpose: To evaluate the influence of patient positioning on dose-volume histograms of organs at risk in external beam radiotherapy for cervical and endometrial cancer. Materials and methods: In 20 patients scheduled for definitive (7) or postoperative (13) external beam radiotherapy of the pelvis treatment planning CT scans were performed in supine and prone (belly board) positions. After volume definition of target and organs at risk treatment plans were calculated applying the four-field box technique. The dose-volume histograms of organs at risk were compared. Results: Radiotherapy in prone position causes a reduction of the bladder portion (mean 15%, p<0.001) and an increase of the rectum portion (mean 11%, p<0.001) within the 90% isodose. A reduction of the bowel portion could only be observed in postoperatively treated patients (mean 13%, p<0.001). In definitive radiotherapy the target volume increases in supine position (mean 7%, p=0.02) due to an anterior tumour/uterus movement, so that bowel portions within the 90% isodose are similar. The bladder filling correlates with a reduction of bladder and bowel (postoperatively treated patients) dose. Conclusions: External beam radiotherapy of the pelvis should be performed in prone position in postoperative patients because of best bowel protection. Considering the additional HDR brachytherapy rectum protection takes the highest priority in definitive treatment--the requirements are best met in supine position. An adequate bladder filling is important to reduce the irradiated bladder and bowel volumes

  7. Parametric oesophageal multiple swallow scintigraphy for validation of dysphageal symptoms during external beam irradiation of mediastinal tumours

    International Nuclear Information System (INIS)

    Brandt-Mainz, K.; Eising, E.G.; Bockisch, A.

    2001-01-01

    The aim of the study was to evaluate dysphageal symptoms and to measure the effect of local analgesic treatment using parametric oesophageal multiple swallow scintigraphy (PES) during external beam irradiation of the mediastinal region. Fifteen patients (most with lung cancer) with dysphagia grade II underwent PES during external beam radiotherapy of the mediastinum before and after application of local analgesics. Dynamic parametric condensed images were recorded. The intensity of clinical symptoms was correlated with the emptying rate at 10 s (ER-10 s) and the mean transit time (MTT). Visual analysis of the images was performed and the results were correlated with the fields of irradiation portals. Of the 15 patients, 12 showed a correlation between irradiation portals and the region of oesophageal motility disorder. Concordant results of clinical symptoms and PES data were found. In nine patients with a decrease in dysphagia following local analgesia, an increase in mean ER-10 s and a decrease in MTT were observed. In three patients with deterioration in clinical symptoms after analgesic treatment, a similar decrease in mean ER-10 s was found, though MTT remained constant. In three patients with normal values, motility disorders were detected in the dynamic study. In conclusion, PES was found to be a sensitive tool for the validation of dysphageal symptoms in patients during external beam irradiation of mediastinal tumours and for the evaluation and quantification of the efficacy of local analgesic treatment. Additional visual analysis of the dynamic study is helpful in diagnosing minimal disorders. (orig.)

  8. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S

    2015-01-01

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  9. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  10. Radical prostatectomy versus external beam radiotherapy for localized prostate cancer. Comparison of treatment outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon-Joo; Cho, Kwan Ho; Lee, Kang Hyun; Moon, Sung Ho; Kim, Tae Hyun; Shin, Kyung Hwan; Kim, Joo-Young; Kim, Young-kyung; Lee, Se Byeong [National Cancer Center, Research Institute and Hospital, Goyang (Korea, Republic of); Pyo, Hong Ryull [Sungkyunkwan University, Department of Radiation Oncology, Samsung Medical Center, School of Medicine, Seoul (Korea, Republic of)

    2015-04-01

    We retrospectively compared the treatment outcomes of localized prostate cancer between radical prostatectomy (RP) and external beam radiotherapy (EBRT). We retrospectively analyzed 738 patients with localized prostate cancer who underwent either RP (n = 549) or EBRT (n = 189) with curative intent at our institution between March 2001 and December 2011. Biochemical failure was defined as a prostate-specific antigen (PSA) level of ≥ 0.2 ng/ml in the RP group and the nadir of + ≥ 2 ng/ml in the EBRT group. The median (range) follow-up duration was 48.8 months (0.7-133.2 months) and 48.7 months (1.0-134.8 months) and the median age was 66 years (45-89 years) and 71 years (51-84 years; p < 0.001) in the RP and EBRT groups, respectively. Overall, 21, 42, and 36 % of patients in the RP group, and 15, 27, and 58 % of patients in the EBRT group were classified as low, intermediate, and high risk, respectively (p < 0.001). Androgen-deprivation therapy was more common in the EBRT group (59 vs. 27 %, respectively; p < 0.001). The 8-year biochemical failure-free survival rates were 44 and 72 % (p < 0.001) and the disease-specific survival rates were 98 % and 97 % (p = 0.543) in the RP and EBRT groups, respectively. Although the EBRT group included more high-risk patients than did the RP group, the outcomes of EBRT were not inferior to those of RP. Our data suggest that EBRT is a viable alternative to RP for treating localized prostate cancer. (orig.) [German] Wir vergleichen retrospektiv die Verfahrensergebnisse des lokal begrenzten Prostatakarzinoms zwischen radikaler Prostatektomie (RP) und externer Strahlentherapie (EBRT). Wir analysieren zurueckblickend 738 Patienten mit lokal begrenztem Prostatakarzinom, die zwischen Maerz 2001 und Dezember 2011 in unserem Institut entweder eine RP (n = 549) oder eine EBRT (n = 189) mit kurativer Intention durchliefen. Biochemischer Fehler wurde als prostataspezifisches Antigen (PSA) ≥ 0,2 ng/ml in der RP-Gruppe und ein Nadir +

  11. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Shaitelman, Simona F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Grace L., E-mail: glsmith@mdanderson.org [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-03-15

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  12. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

    International Nuclear Information System (INIS)

    Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Ciocca, Mario; Riboldi, Marco; Baroni, Guido; Orecchia, Roberto

    2015-01-01

    Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring

  13. A retrospective analysis of 140 dogs with oral melanoma treated with external beam radiation.

    Science.gov (United States)

    Proulx, David R; Ruslander, David M; Dodge, Richard K; Hauck, Marlene L; Williams, Laurel E; Horn, Birgitte; Price, G Sylvester; Thrall, Donald E

    2003-01-01

    Despite the early notion that canine oral malignant melanoma is radioresistant, recent data suggest that external beam radiotherapy is effective in local tumor control. However, optimal fractionation schedules have not been established. The high rate of regional and distant metastasis is another problem that has hindered long-term control. The role of chemotherapy in the management of canine oral melanoma has also not been determined. In this study, data from 140 dogs irradiated at North Carolina State University were evaluated with the following objectives: (1) to compare the efficacy of three radiation therapy protocols (36 Gy, 9 Gy x 4 fractions; 30 Gy, 10 Gy x 3 fractions; or >45 Gy, 2-4 Gy x 12-19 fractions) for the treatment of dogs with oral malignant melanoma, (2) to identify any host or tumor factors influencing prognosis, and (3) to determine the impact of systemic chemotherapy on treatment outcome. Information regarding response to therapy, disease progression, and survival were determined from the medical records or from information obtained by telephone or mail survey. Relationships between host, tumor, and treatment variables and outcome measures (response, time to first event, and survival) were evaluated using Fisher's exact test (response) and the Cox regression model (time to first event and survival). The median time to first event for the 140 dogs was 5.0 months (95% C.I., 4-6 months) and the median survival was 7.0 months (95% C.I., 6-9 months). In the univariate analysis, the following variables were associated with increased time to first event and survival: (1) rostral tumor sublocation; (2) lack of bone lysis observed on skull imaging, and (3) microscopic tumor burden. In a multivariate analysis of 111 dogs with complete data for these variables, tumor sublocation, bone lysis, and tumor volume were identified as joint predictors of time to first event (p oral malignant melanoma; however, the optimal fractionation scheme has yet to be

  14. DOSE-ESCALATED EXTERNAL BEAM RADIOTHERAPY DURING HORMONO-RADIOTHERAPY FOR PROSTATE CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2016-01-01

    Full Text Available Introduction. The introduction of modern technologies of conformal external beam radiotherapy (EBRT into clinical practice for the treatment of prostate cancer requires proper quality assurance measures as well as a careful analysis of both the efficacy and toxicity data of treatments. The purpose of this study was to inves- tigate tolerance and the immediate efficacy of conformal dose-escalated EBRT during hormono-radiotherapy for prostate cancer. material and methods. The study involved 156 prostate cancer patients treated with EBRT. Among them, 30 patients received a total dose of 70 Gy, and in 126 patients the total dose was esca- lated to 72-76 Gy (median total dose - 74.0 Gy. Fifty-nine patients received intensity modulated radiation therapy. Results. The prescribed course of treatment was completed in all the patients with prostate cancer. Acute radiation-induced bladder reactions (RTOG were observed in 50 (32.1 % patients, of whom 48 (30.8 % experienced grade I reactions, and 2 (1.3 % experienced grade II reactions. Eighteen (11.5 % patients had radiation-induced rectum reactions, not above grade I. The development of grade II dysuric phenomena necessitated treatment interruption only in two patients. Of 9 (5.8 % patients who had late bladder complica- tions (RTOG/EORTC, 8 (5.1 % patients developed grade I complications, and one (0.6 % patient developed grade II complications. Of 11 (7.1 % patients who had rectum complications, 8 (5.1 % patients developed grade I complications, and 3 (1.9 % patients developed grade II complications. No patients experienced the increase in toxicity of treatment during dose escalation up to a total dose exceeding 70 Gy. During the follow-up period, only one patient developed recurrent disease. Conclusion. The results of our study suggest acceptable levels of toxicity following a continuous course of dose-escalated EBRT given in conjunction with hormono-radiotherapy to prostate cancer patients. Further

  15. SU-F-J-11: Radiobiologically Optimized Patient Localization During Prostate External Beam Localization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y; Gardner, S; Liu, C; Zhao, B; Wen, N; Brown, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To present a novel positioning strategy which optimizes radiation delivery with radiobiological response knowledge, and to evaluate its application during prostate external beam radiotherapy. Methods: Ten patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions with PTV = prostate + 7 mm margin, except for 5mm in the posterior direction. Five representative pretreatment CBCT images were selected for each patient, and prostate, rectum, and bladder were delineated on all CBCT images. Each CBCT was auto-registered to the corresponding PCT. Starting from this auto-matched position (AM-position), a search for optimal treatment position was performed utilizing a score function based on radiobiological and dosimetric indices (D98-DTV, NTCP-rectum, and NTCP-bladder) for the daily target volume (DTV), rectum, and bladder. DTV was defined as prostate + 4 mm margin to account for intra-fraction motion as well as contouring variability on CBCT. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The indices, averaged over the 10 patients’ treatment plans, were (mean±SD): 77.7±0.2 Gy (D98-PTV), 12.3±2.7% (NTCP-rectum), and 53.2±11.2% (NTCP-bladder). The corresponding values calculated on all 50 CBCT images at the AM-positions were 72.9±11.3 Gy (D98-DTV), 15.8±6.4% (NTCP-rectum), and 53.0±21.1% (NTCP-bladder), respectively. In comparison, calculated on CBCT at the ROCS-positions, the indices were 77.0±2.1 Gy (D98-DTV), 12.1±5.7% (NTCP-rectum), and 60.7±16.4% (NTCP-bladder). Compared to autoregistration, ROCS-optimization recovered dose coverage to target volume and lowered the risk to rectum. Moreover, NTCPrectum for one patient remained high after ROCS-optimization and therefore could potentially benefit from adaptive planning

  16. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    International Nuclear Information System (INIS)

    Shiraishi, Satomi; Moore, Kevin L.

    2016-01-01

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D clin − D pred . The mean (〈δD r 〉), standard deviation (σ δD r ), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r PTV ) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r PTV ∈ [ − 6, 30] mm. The average prediction error was less

  17. External beam irradiation for choroid metastases: identification of factors predisposing to long-term sequelae

    International Nuclear Information System (INIS)

    Rudoler, Shari B.; Corn, Benjamin W.; Shields, Carol L.; De Potter, Patrick; Hyslop, Terry; Shields, Jerry A.; Curran, Walter J.

    1997-01-01

    Purpose: To improve overall quality of life, palliative treatments should attempt to minimize associated complications while effectively controlling specific symptoms. We reviewed our experience treating posterior uveal metastases with external beam radiotherapy (EBRT) to determine the complication rate and to identify the relationship between patient, tumor, or treatment-related factors and the development of ocular complications. Methods and Materials: 483 consecutive patients (pts) (578 eyes) were diagnosed with intraocular metastatic disease from solid tumors between 1972-1995. Of these, 233 eyes (188 pts) had lesions of the posterior uveal tract and received EBRT. Median follow-up time was 5.8 months (range: 0.7-170.0 months). Follow-up information regarding the development of complications was documented for 230 eyes. Complete EBRT details were available for 189 eyes. Seventy-two percent of the patients received 30.0-40.0 Gy in 2.0-3.0 Gy fractions. Biologically effective dose (BED) was calculated to allow meaningful comparisons between various fractionation regimens and total doses. Concurrent chemotherapy and/or hormonal therapy was used for 101 eyes (44%). Results: Median BED was 61 Gy 3 (range, 6.7-105 Gy 3 ), and 80% of treated eyes received BED 50-70 Gy 3 . EBRT energies included photons (70%), 60 Co (19%), electrons (6%), mixed energies (3%), and orthovoltage (2%). Lens-sparing techniques were used in 136 eyes (71%). At last follow-up 28 eyes (12%) developed one or more significant complications, including cataracts (16 eyes), radiation retinopathy (6 eyes), optic neuropathy (5 eyes), exposure keratopathy (5 eyes), and neovascularization of the iris (4 eyes). Two eyes developed narrow-angle glaucoma, and one of these required enucleation. On univariate analysis, Caucasian race (vs. Black/Hispanic, p = 0.03), increased intraocular pressure at diagnosis (>21 mmHg, p = 0.02), and diagnosis by biopsy (vs. no biopsy, p = 0.03) predisposed toward the

  18. Kinetics of serum prostate-specific antigen after external beam radiation for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Zagars, Gunar K.; Pollack, Alan

    1997-01-01

    Background and purpose: To determine the kinetics of serum prostate-specific antigen (PSA) after radiation therapy of localized prostate cancer and to evaluate whether such kinetics provide prognostic information. Materials and methods: Eight hundred forty-one men with serial PSA determinations who underwent external beam radiation without androgen ablation were analyzed to determine postradiation PSA kinetic parameters (half-life and doubling time) and to correlate these parameters with disease outcome. Non-linear regression techniques were used to determine half-lives and doubling times. Results: The postradiation serum PSA data fitted well to first order kinetic models. The median PSA half-life was 1.6 months (range 0.5-9.2 months). There was no correlation between half-life and T-stage or Gleason grade. A significant but quantitatively weak correlation was present between the pretreatment PSA level and half-life; lower pretreatment levels were associated with longer half-lives. Half-life did not correlate with disease outcome whether the endpoint was local recurrence, distant metastasis or rising PSA. In 263 men with a rising postradiation PSA profile the median PSA doubling time was 12.2 months (range 0.8-80.2 months). Faster doubling times were significantly associated with higher T-stage, higher Gleason grade and higher pretreatment PSA levels. Thus, patients with initially adverse disease developed faster rising PSA values after treatment than patients with less adverse disease. The most striking correlation was between rapid doubling time and the likelihood of metastatic relapse. Patients who developed metastases had a median PSA doubling time of 4.2 months compared to a median doubling time of 11.7 months in patients who developed local recurrence. Overall, patients with a PSA doubling time of less than 8 months had a 7-year actuarial metastatic rate of 54%, while patients with a PSA doubling time exceeding 8 months had only a 7% metastatic rate

  19. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Via, Riccardo, E-mail: riccardo.via@polimi.it; Fassi, Aurora; Fattori, Giovanni [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano 20133 (Italy); Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Ciocca, Mario [CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100 (Italy); Riboldi, Marco; Baroni, Guido [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano 20133, Italy and CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100 (Italy); Orecchia, Roberto [CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy and European Institute of Oncology, Milano 20141 (Italy)

    2015-05-15

    Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring

  20. The value of external beam radiation in pathologic node positive prostate cancer: a multivariate analysis

    International Nuclear Information System (INIS)

    Morris, Astrid D.; Zietman, Anthony L.; Althausen, Alex F.; Heney, Niall M.; Kaufman, Donald S.; Shipley, William U.

    1997-01-01

    Purpose: The goal of this study was to evaluate the effect of local/regional treatment, particularly external beam radiation alone versus radical prostatectomy and radiation therapy in patients with pathologic node positive prostate cancer on survival. The effect of delayed vs. immediate endocrine therapy on patients treated with radiation alone was also examined. Methods: Medical records of all 116 patients who received their initial treatment at the Massachusetts General Hospital between 1980 and 1996 for adenocarcinoma of the prostate with pathologic confirmed nodal metastasis and no distant disease were reviewed. The mean follow up was 5.5 years. Disease specific survival, time to PSA failure on endocrine therapy, and time to first intervention were evaluated. PSA failure was defined as two consecutive post-nadir rises following the first use of endocrine therapy. Intervention was defined as any surgical or radiotherapeutic procedure required for relief of symptoms related to local/regional recurrence. Survival comparisons were made between any local/regional treatment vs. none, radiation therapy alone vs. prostatectomy with radiation therapy, and immediate vs. delayed endocrine therapy. The effect of the different treatment options on survival were compared using multivariate Cox proportional hazard models to simultaneously adjust for patient and tumor characteristics (tumor stage, Gleason grade, number of positive nodes) that might influence survival. Results: The combined patient population had a 5 year disease specific survival of 74% and a 10 year disease specific survival of 48%. The comparison groups for local/regional treatment had the following adjusted outcomes. In a subgroup analysis of patients with clinical T1-T2 and clinical T3-T4 disease, local/regional treatment continued to confer a disease specific survival advantage over no local regional treatment in both subgroups (p=0.05 and p=0.02, respectively). PSA failure on endocrine therapy was

  1. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Satomi; Moore, Kevin L., E-mail: kevinmoore@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California 92093 (United States)

    2016-01-15

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D{sub clin} − D{sub pred}. The mean (〈δD{sub r}〉), standard deviation (σ{sub δD{sub r}}), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r{sub PTV}) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r{sub PTV} ∈ [ − 6, 30] mm. The

  2. Spill control and intensity monitoring for the Bevatron--Bevalac external particle beams

    International Nuclear Information System (INIS)

    Barale, J.J.; Crebbin, K.C.

    1975-03-01

    Time-intensity modulation in beam spill can be of primary concern in some experiments. The major source of this beam structure is from main-guide field-magnet power supply ripple. If the time constants are appropriate, then final control of beam structure can be accomplished by closed loop control of the intensity of beam spill. The response characteristics of the feedback system will determine the final structure. At high beam fluxes signal to noise ratio of beam detectors, in the feedback loop, can be improved by at least four orders of magnitude by using photomultiplier tubes and a water Cherenkov counter in place of the normal secondary emission monitor. At beam fluxes below 10 10 particles per second (PPS), a plastic scintillator and photomultiplier tube are used in the feedback system. A plastic scintillator and photomultiplier are also used in the beam as intensity monitors. At intensities below about 10 7 PPS standard counting techniques are used. For intensities between 10 6 to 110 9 PPS, the photomultiplier is used as a current source driving an integrating circuit which is then calibrated to read the number of particles per pulse. (U.S.)

  3. Primary Vaginal Cancer Treated With Concurrent Chemoradiation Using Cis-Platinum

    International Nuclear Information System (INIS)

    Samant, Rajiv; Lau, Bedy; E, Choan; Le, Tien; Tam, Tiffany

    2007-01-01

    Purpose: To evaluate the feasibility of concurrent weekly Cis-platinum chemoradiation (CRT) in the curative treatment of primary vaginal cancer. Methods: A retrospective review was performed of all primary vaginal cancer patients treated with curative intent at the Ottawa Hospital Regional Cancer Centre between 1999 and 2004 using concurrent Cis-platinum CRT. Results: Twelve patients were treated with concurrent weekly CRT. The median age at diagnosis was 56 years (range, 34-69 years), and the median follow-up was 50 months (range, 11-75 months). Ten patients (83%) were diagnosed with squamous cell carcinoma and 2 patients (17%) with adenocarcinoma. The distribution according to stage was as follows: 6 (50%) Stage II, 4 (33%) Stage III, and 2 (17%) Stage IVA. All patients received pelvic external beam radiotherapy (EBRT) concurrently with weekly intravenous Cis-platinum chemotherapy (40 mg/m 2 ) followed by brachytherapy (BT). The median dose of EBRT was 4500 cGy given in 25 fractions over 5 weeks. Ten patients received interstitial BT, and 2 patients received intracavitary BT, with the median dose being 3000 cGy. The 5-year overall survival, progression-free survival, and locoregional progression-free survival rates were 66%, 75%, and 92%, respectively. Late toxicity requiring surgery occurred in 2 patients (17%). Conclusions: For the treatment of primary vaginal cancer, it is feasible to deliver concurrent weekly Cis-platinum chemotherapy with high-dose radiation, leading to excellent local control and an acceptable toxicity profile

  4. SU-F-T-471: Simulated External Beam Delivery Errors Detection with a Large Area Ion Chamber Transmission Detector

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Dyer, B; Kumaran Nair, C; Stern, R; Benedict, S; Davis, UC [Cancer Center, Sacramento, CA (United States)

    2016-06-15

    Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected for simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external

  5. A new small-footprint external-beam PIXE facility for cultural heritage applications using pulsed proton beams

    Science.gov (United States)

    Vadrucci, M.; Bazzano, G.; Borgognoni, F.; Chiari, M.; Mazzinghi, A.; Picardi, L.; Ronsivalle, C.; Ruberto, C.; Taccetti, F.

    2017-09-01

    In the framework of the COBRA project, elemental analyses of cultural heritage objects based on the particle induced X-ray emission (PIXE) are planned in a collaboration between the APAM laboratory of ENEA-Frascati and the LABEC laboratory of INFN in Florence. With this aim a 3-7 MeV pulsed proton beam, driven by the injector of the protontherapy accelerator under construction for the TOP-IMPLART project, will be used to demonstrate the feasibility of the technique with a small-footprint pulsed accelerator to Italian small and medium enterprises interested in the composition analysis of ancient artifacts. The experimental set-up for PIXE analysis on the TOP-IMPLART machine consists of a modified assembly of the vertical beam line usually dedicated to radiobiology experiments: the beam produced by the injector (RFQ + DTL, a PL7 ACCSYSHITACHI model) is bent to 90° by a magnet, is collimated by a 300 μm aperture inserted in the end nozzle and extracted into ambient pressure by an exit window consisting of a Upilex foil 7.5 μm thick. The beam is pulsed with a variable pulse duration of 20-100 μs and a repetition rate variable from 10 to 100 Hz. The X-ray detection system is based on a Ketek Silicon Drift Detector (SDD) with 7 mm2 active area and 450 μm thickness, with a thin Beryllium entrance window (8 μm). The results of the calibration of this new PIXE set-up using thick target standards and of the analysis of the preliminary measurements on pigments are presented.

  6. Effect of Shear Resistance on Flexural Debonding Load-Carrying Capacity of RC Beams Strengthened with Externally Bonded FRP Composites

    Directory of Open Access Journals (Sweden)

    Guibing Li

    2014-05-01

    Full Text Available Debonding failure is the main failure mode in flexurally strengthened reinforced concrete beams by externally bonded or near surface mounted fibre reinforced polymer (FRP composites. It is believed that FRP debonding will be initiated if the shear stress on the concrete-FRP interface reaches the tensile strength of concrete. However, it was found through experimental and analytical studies that the debonding mechanism of FRP composites has the potential of shear failure in combination with debonding failure. Moreover, the shear failure probably influences the debonding failure. Presently, there are very little experimental and analytical studies to investigate the influence of shear resistance of reinforced concrete (RC beam on FRP debonding failure. The current study investigates and analyzes the effect of shear resistance on FRP debonding failure based on test results. The analytical results show that the shear resistance of RC beam has a great effect on flexural debonding load-carrying capacity of FRP-strengthened RC beam. The influence of shear resistance on flexural debonding load-carrying capacity must be fully considered in flexural strengthening design of RC beams.

  7. Phase space generation for proton and carbon ion beams for external users’ applications at the Heidelberg Ion Therapy Center

    Directory of Open Access Journals (Sweden)

    Thomas eTessonnier

    2016-01-01

    Full Text Available In the field of radiation therapy, accurate and robust dose calculation is required. For this purpose, precise modeling of the irradiation system and reliable computational platforms are needed. At the Heidelberg Ion Therapy Center (HIT, the beamline has been already modeled in the FLUKA Monte Carlo code. However, this model was kept confidential for disclosure reasons and was not available for any external team. The main goal of this study was to create efficiently phase space (PS files for proton and carbon ion beams, for all energies and foci available at HIT. PS are representing the characteristics of each particle recorded (charge, mass, energy, coordinates, direction cosines, generation at a certain position along the beam path. In order to achieve this goal, keeping a reasonable data size but maintaining the requested accuracy for the calculation, we developed a new approach of beam PS generation with the Monte-Carlo code FLUKA. The generated PS were obtained using an infinitely narrow beam and recording the desired quantities after the last element of the beamline, with a discrimination of primaries or secondaries. In this way, a unique PS can be used for each energy to accommodate the different foci by combining the narrow-beam scenario with a random sampling of its theoretical Gaussian beam in vacuum. PS can also reproduce the different patterns from the delivery system, when properly combined with the beam scanning information. MC simulations using PS have been compared to simulations including the full beamline geometry and have been found in very good agreement for several cases (depth dose distributions, lateral dose profiles, with relative dose differences below 0.5%. This approach has also been compared with measured data of ion beams with different energies and foci, resulting in a very satisfactory agreement. Hence, the proposed approach was able to fulfill the different requirements and has demonstrated its capability for

  8. Fibrocellular tissue responses to endovascular and external beam irradiation in the porcine model of restenosis

    International Nuclear Information System (INIS)

    Marijianowski, Monique M.H.; Crocker, Ian R.; Styles, Terry; Forestner, Donna M.; Waksman, Ron; Cipolla, Gustavo D.; King, Spencer B.; Robinson, Keith A.

    1999-01-01

    Purpose: Endovascular radiation has reduced postangioplasty restenosis in preclinical and early clinical studies. External radiation treatment may have advantages over endovascular therapy. We examined vascular and perivascular tissue responses to endovascular and external irradiation in pig coronary arteries. Methods and Materials: Ninety-one animals received endovascular or external radiation following balloon injury and were sacrificed at 14, 30, or 180 days. Injured segments of coronary vessels including perivascular and myocardial tissues were evaluated with histochemistry. Results: Endovascular radiation was associated with delayed arterial wound healing as late as 6 months, evidenced by paucity of smooth muscle α-actin in neointimal cells compared to control. External treatment was associated with increased collagen in neointima and adventitia, and focal interstitial necrosis in adjacent myocardium. Conclusions: These investigations showed whole-heart 14 Gy external radiation treatment following coronary injury exacerbated certain aspects of arterial healing. In addition focal myocardial necrosis and fibrosis was observed following external but not endovascular irradiation. Endovascular radiation has some advantages over external irradiation; however the persistence of a synthetic smooth muscle cell phenotype in the neointima at 6 months suggests ionizing radiation in general may have profound effects on vessel architecture over the long term

  9. Organ localization in fractionated external beam radiotherapy for early stage prostatic adenocarcinoma

    International Nuclear Information System (INIS)

    Jaffray, D.A.; Horwitz, E.M.; Wong, J.W.; Martinez, A.A.; Brabbins, D.S.

    1996-01-01

    Purpose: Trends toward higher target doses and more conformal radiation field shaping place strict requirements on geometric localisation of the target and surrounding normal structures. Daily localization of these structures is not possible on a conventional treatment machine. For this reason, margins must be incorporated in the field shaping to accommodate any target or normal structure displacement. There are few studies which examine the magnitude of these displacements. We hypothesize that these uncertainties can be reduced by daily radiographic imaging of bony anatomy as an alternative to skin tattoos. This hypothesis is tested using multiple (15-19) CT scans on five patients receiving external beam radiotherapy of the prostate. Materials and Methods: Five patients were CT scanned in treatment position (with immobilization device) on every second day of their initial XRT course (non-boost). Radiopaque markers were placed on the skin tattoos to make them visible in the CT datasets. The scans were collected on a helical CT scanner (SR-7000, 3mm and 5mm slice thickness, 120kVp) and transferred to a workstation for analysis. The structures (prostate, rectum, bladder, and seminal vesicles) on all 80 CT datasets were contoured (manually) by two physicians. A reference dataset was chosen for each patient. The 3D transformations between the study datasets and the reference set were determined using an automated technique. A separate transformation was determined for the alignment of (i) bone (excluding femora) and (ii) skin marks. The contours from each dataset were then transformed back to the reference dataset. The resulting contours show the position of organ relative to either the skin marks (tattoos) or the bony anatomy. The displacement and distortion of the organs were parameterized by the displacement of the volume edge (AP, LAT, SUP-INF), volume, and center-of-mass (COM). Each calculation was performed for an individual patient. Population averages were also

  10. Adjuvant high-dose-rate brachytherapy after external beam radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, Enis; Yildz, Ferah; Akyol, Fadil H.; Atahan, I. Lale

    2002-01-01

    Purpose: To compare the local control and survival rates obtained with either external beam radiation therapy (ERT) and adjuvant high-dose-rate (HDR) brachytherapy (BRT) or ERT alone in patients with nasopharyngeal cancer. Methods and Materials: Between December 1993 and December 1999, 144 patients (106 male, 38 female) with the diagnosis of nasopharyngeal cancer were treated with either ERT and adjuvant HDR BRT (Group A) or ERT alone (Group B) at our department. BRT was not applied in 38 patients for the following reasons: (1) Unit was unavailable (n=13), (2) Patient was younger than 18 years (n=17), (3) Patient received accelerated hyperfractionated ERT (n=6), and (4) Patient refused BRT (n=2). The median age for whole group was 43 (range: 9-82 years). According to the AJCC-1997 staging system, there were 11 (7.6%), 35 (24.3%), 38 (26.4%), and 60 (41.7%) patients in Stage I, II, III, and IV, respectively. There were 57 (39.6%) patients with T1, 41 (28.5%) with T2, 20 (13.9%) with T3, and 26 (18.1%) with T4 tumors. Histopathologic diagnosis was WHO 2-3 in 137 (95.2%) patients. ERT doses ranged between 58.8 and 74 Gy (median: 66 Gy). There were significantly more patients with young age, N2 status, and Stage III disease in Group B and with Stage II disease in Group A. Significantly more patients received chemotherapy in Group B. BRT with an HDR 192 Ir microSelectron afterloading unit was delivered in 106 patients at the conclusion of ERT using a single-channel nasal applicator. Dose was prescribed at 1 cm from the source, and total dose of 12 Gy in 3 fractions on 3 consecutive days was given immediately after ERT. Besides radiotherapy, 82 (56.9%) patients received cisplatin-based chemotherapy, as well. Follow-up time ranged between 12 and 80 months (median: 32 months). Results: The two groups were comparable in terms of local recurrence, locoregional failure, regional failure, and rate of distant metastasis. Local failure was observed in 11 (10.3%) out of 106

  11. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Paulson, Eric S., E-mail: epaulson@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 and Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Erickson, Beth; Schultz, Chris; Allen Li, X. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States)

    2015-01-15

    Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In

  12. The development of an interdepartmental audit as part of a physics quality assurance programme for external beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bonnett, D.E.; Jaukett, R.J. (Royal Infirmary, Leicester (United Kingdom)); Mills, J.A.; Martin-Smith, P. (Walsgrave Hospital, Coventry (United Kingdom))

    1994-03-01

    A cost-effective audit system has been developed that will both detect systematic error in data and procedures, and evaluate the quality assurance programme provided by a physics department for radiotherapy. The audit has been developed for external beam radiotherapy and assesses one modality and one treatment machine per year. The method of assessing the quality assurance programme and the schedule of measurements are described. The process is illustrated using the results of trial audits between the medical physics department at Coventry and Leicester. (author).

  13. A Long Term Results of External Beam Radiation Therapy in Hemophilic Arthropathy of the Ankle in Children

    OpenAIRE

    Kong, Moonkyoo; Kang, Jin Oh; Choi, Jinhyun; Park, Seo Hyun

    2010-01-01

    Bleeding into joint space is critical to develop hemophilic arthropathy. To reduce the frequency of bleeding in the ankle joint of children with hemophilic arthropathy, low dose external beam irradiation was performed for 37 patients. Among them, 35 patients followed-up for longer than 1 yr (median 87 months) were enrolled for analysis. The average number of bleedings per month was 3.6 during one year prior to radiation therapy. After radiation therapy, it was decreased to 2.1 during the firs...

  14. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    Energy Technology Data Exchange (ETDEWEB)

    Sole, C.V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Calvo, F.A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lozano, M.A.; Gonzalez-Sansegundo, C. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Gonzalez-Bayon, L. [Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Alvarez, A. [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lizarraga, S. [Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Garcia-Sabrido, J.L. [Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain)

    2014-02-15

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  15. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    International Nuclear Information System (INIS)

    Sole, C.V.; Calvo, F.A.; Lozano, M.A.; Gonzalez-Sansegundo, C.; Gonzalez-Bayon, L.; Alvarez, A.; Lizarraga, S.; Garcia-Sabrido, J.L.

    2014-01-01

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  16. Intraoperative electron beam therapy and external photon beam therapy with lumpectomy as primary treatment for early breast cancer

    International Nuclear Information System (INIS)

    Dobelbower, R.R.; Merrick, H.W.; Eltaki, A.; Bronn, D.G.

    1989-01-01

    Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeV electrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. Clinical and technical aspects of treatment are presented along with the rationale for the use of IOEBT in the primary definitive radiotherapeutic management of early breast cancer

  17. Study of Italian Renaissance sculptures using an external beam nuclear microprobe

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J.R.

    2000-01-01

    The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented

  18. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

    DEFF Research Database (Denmark)

    Knöös, Tommy; Wieslander, Elinore; Cozzi, Luca

    2006-01-01

    cancer cases. The TPSs were installed locally at different institutions and commissioned for clinical use based on local procedures. For the evaluation, beam qualities as identical as possible were used: low energy (6 MV) and high energy (15 or 18 MV) x-rays. All relevant anatomical structures were...

  19. Nonlinear finite element modeling of concrete deep beams with openings strengthened with externally-bonded composites

    International Nuclear Information System (INIS)

    Hawileh, Rami A.; El-Maaddawy, Tamer A.; Naser, Mohannad Z.

    2012-01-01

    Highlights: ► A 3D nonlinear FE model is developed of RC deep beams with web openings. ► We used cohesion elements to simulate bond. ► The developed FE model is suitable for analysis of such complex structures. -- Abstract: This paper aims to develop 3D nonlinear finite element (FE) models for reinforced concrete (RC) deep beams containing web openings and strengthened in shear with carbon fiber reinforced polymer (CFRP) composite sheets. The web openings interrupted the natural load path either fully or partially. The FE models adopted realistic materials constitutive laws that account for the nonlinear behavior of materials. In the FE models, solid elements for concrete, multi-layer shell elements for CFRP and link elements for steel reinforcement were used to simulate the physical models. Special interface elements were implemented in the FE models to simulate the interfacial bond behavior between the concrete and CFRP composites. A comparison between the FE results and experimental data published in the literature demonstrated the validity of the computational models in capturing the structural response for both unstrengthened and CFRP-strengthened deep beams with openings. The developed FE models can serve as a numerical platform for performance prediction of RC deep beams with openings strengthened in shear with CFRP composites.

  20. Complete response in a patient with gynecological hidradenocarcinoma treated with exclusive external beam radiotherapy and brachytherapy: a case report.

    Science.gov (United States)

    Giannelli, Flavio; Chiola, Ilaria; Belgioia, Liliana; Garelli, Stefania; Pastorino, Alice; Marcenaro, Michela; Mammoliti, Serafina; Costantini, Sergio; Bizzarri, Nicolò; Vellone, Valerio; Barra, Salvina; Corvò, Renzo

    2017-12-01

    Hidradenocarcinoma (HC) is a very rare disease. This case report illustrates a successful treatment of a 60-year-old woman with vulvo-vaginal localization of hidradenocarcinoma treated with external beam radiotherapy delivered by helical tomotherapy with a simultaneous integrated boost (SIB), followed by brachytherapy. External beam radiotherapy dose prescription was 50.4 Gy in 28 fractions, five fractions per week to whole pelvis (planning target volume 1 - PTV1), 60.2 Gy in 28 fractions to SIB1 (fundus of uterus and right inguinal node), and 58.8 Gy in 28 fractions to SIB2 (lower/middle third of vagina, paraurethral region and right inguinal lymph nodes). Brachytherapy dose prescription was 28 Gy in 4 fractions for cervix, fundus of uterus and upper third of vagina (HR-CTV1), and 22 Gy in 4 fractions to middle third of vagina and paraurethral region (HR-CTV2). D 90 for whole treatment was 91.9 Gy and 86.0 Gy for HR-CTV1 and HR-CTV2, respectively. Patient remained 12-months disease-free without treatment related side effects.

  1. Complete response in a patient with gynecological hidradenocarcinoma treated with exclusive external beam radiotherapy and brachytherapy: a case report

    Directory of Open Access Journals (Sweden)

    Flavio Giannelli

    2017-12-01

    Full Text Available Hidradenocarcinoma (HC is a very rare disease. This case report illustrates a successful treatment of a 60-year-old woman with vulvo-vaginal localization of hidradenocarcinoma treated with external beam radiotherapy delivered by helical tomotherapy with a simultaneous integrated boost (SIB, followed by brachytherapy. External beam radiotherapy dose prescription was 50.4 Gy in 28 fractions, five fractions per week to whole pelvis (planning target volume 1 – PTV1, 60.2 Gy in 28 fractions to SIB1 (fundus of uterus and right inguinal node, and 58.8 Gy in 28 fractions to SIB2 (lower/middle third of vagina, paraurethral region and right inguinal lymph nodes. Brachytherapy dose prescription was 28 Gy in 4 fractions for cervix, fundus of uterus and upper third of vagina (HR-CTV1, and 22 Gy in 4 fractions to middle third of vagina and paraurethral region (HR-CTV2. D90 for whole treatment was 91.9 Gy and 86.0 Gy for HR-CTV1 and HR-CTV2, respectively. Patient remained 12-months disease-free without treatment related side effects.

  2. Beyond the conventional role of external-beam radiation therapy for skeletal metastases: new technologies and stereotactic directions.

    Science.gov (United States)

    Yu, H-H M; Hoffe, S E

    2012-04-01

    Radiation therapy is a common and effective treatment modality in the management of skeletal metastases. Recent advances in technology permitting delivery of an ablative radiation dose with an image-guided stereotactic approach improve the therapeutic threshold. The authors reviewed the literature on conventional external-beam radiation therapy and summarized the emerging data about image-guided stereotactic body radiation therapy (SBRT) for vertebral oligometastasis. Pain control can be achieved effectively with conventional external-beam radiation therapy and may be further improved with image-guided spinal SBRT. Image-guided SBRT allows delivery of an ablative radiation dose with minimal toxicity, may potentially improve local tumor control, and may enhance clinical outcomes for histologies that are considered radioresistant. However, further understanding of long-term normal tissue toxicity is lacking. Radiotherapy options are expanding for patients with skeletal metastases. Image-guided spinal SBRT can deliver a safe ablative radiation dose to improve pain control and potentially local tumor control. Randomized clinical trials are ongoing to assess clinical benefits and outcome with spinal SBRT.

  3. Noninvasive referencing of intraocular tumors for external beam radiation therapy using optical coherence tomography: A proof of concept

    International Nuclear Information System (INIS)

    Rüegsegger, Michael B.; Steiner, Patrick; Kowal, Jens H.; Geiser, Dominik; Pica, Alessia; Aebersold, Daniel M.

    2014-01-01

    Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors

  4. Low-dose-rate intraoperative brachytherapy combined with external beam irradiation in the conservative treatment of soft tissue sarcoma

    International Nuclear Information System (INIS)

    Delannes, M.; Thomas, L.; Martel, P.; Bonnevialle, P.; Stoeckle, E.; Chevreau, Ch.; Bui, B.N.; Daly-Schveitzer, N.; Pigneux, J.; Kantor, G.

    2000-01-01

    Purpose: Conservative treatment of soft tissue sarcomas most often implies combination of surgical resection and irradiation. The aim of this study was to evaluate low-dose-rate intraoperative brachytherapy, delivered as a boost, in the local control of primary tumors, with special concern about treatment complications. Methods and Materials: Between 1986 and 1995, 112 patients underwent intraoperative implant. This report focuses on the group of 58 patients with primary sarcomas treated by combination of conservative surgery, intraoperative brachytherapy, and external irradiation. Most of the tumors were located in the lower limbs (46/58--79%). Median size of the tumor was 10 cm, most of the lesions being T2-T3 (51/58--88%), Grade 2 or 3 (48/58--83%). The mean brachytherapy dose was 20 Gy and external beam irradiation dose 45 Gy. In 36/58 cases, iridium wires had to be placed on contact with neurovascular structures. Results: With a median follow-up of 54 months, the 5-year actuarial survival was 64.9%, with a 5-year actuarial local control of 89%. Of the 6 patients with local relapse, 3 were salvaged. Acute side effects, essentially wound healing problems, occurred in 20/58 patients, late side effects in 16/58 patients (7 neuropathies G2 to G4). No amputation was required. The only significant factor correlated with early side effects was the location of the tumor in the lower limb (p = 0.003), and with late side effects the vicinity of the tumor with neurovascular structures (p = 0.009). Conclusion: Brachytherapy allows early delivery of a boost dose in a reduced volume of tissue, precisely mapped by the intraoperative procedure. Combined with external beam irradiation, it is a safe and efficient treatment technique leading to high local control rates and limited functional impairment

  5. Effects of external environments on the short beam shear strength of filament wound graphite/epoxy

    Science.gov (United States)

    Penn, B. G.; Clemons, J. M.

    1986-01-01

    Filament wound graphite/epoxy samples were immersed in seawater, deionized water, and toluene at room temperature and 80 deg C for 5, 15, and 43 days, and in methanol at room temperature for 15 and 43 days. The percent weight gains and short beam shear strengths were determined after environmental exposure. Samples immersed in deionized water and seawater had higher percent weight gains than those immersed in toluene at room temperature and 80 deg C. The percent weight gains for samples immersed in methanol at room temperature were comparable to those of deionized water and seawater immersed samples. A comparison of percent decreases in short beam shear strengths could not be made due to a large scatter in data. This may indicate defects in samples due to machining or variations in material properties due to processing.

  6. Study of national dosimetric standards for external beam radiotherapy: application to conformal irradiations

    International Nuclear Information System (INIS)

    Le Roy, M.

    2011-01-01

    The development of new treatment modalities such as IMRT and stereotactic radiotherapy has led to an increasing use of complex fields composed of small beams with multiple incidence angles. These new treatment conditions are very far from classical reference conditions on which international dosimetry protocols are based. In this work, we propose to realize dosimetric standards for radiation fields smaller than the standard 10 * 10 cm 2 field, namely 4 * 4 and 2 * 2 cm 2 . The calibration coefficients of an ionization chamber in terms of absorbed dose to water for these radiation fields were compared in the 6 MV (with and without flattening filter) and 12 MV beams of LNHB medical linac. The references were established from a graphite calorimetry measurement. A graphite calorimeter of small sensitive volume was built specifically for the 2 * 2 cm 2 field. In addition, an ionization chamber suitable to this field size was looked for. We showed that, for the studied beams, the reference chamber's calibration coefficient is independent of the radiation field size between 10 * 10 and 2 * 2 cm 2 , within uncertainties (about 0.4 % at one standard deviation). (author) [fr

  7. Concurrent chemoradiation for vaginal cancer.

    Directory of Open Access Journals (Sweden)

    David T Miyamoto

    Full Text Available BACKGROUND: It is not known whether the addition of chemotherapy to radiation therapy improves outcomes in primary vaginal cancer. Here, we review clinical outcomes in patients with primary vaginal cancer treated with radiation therapy (RT or concurrent chemoradiation therapy (CRT. METHODS: Seventy-one patients with primary vaginal cancer treated with definitive RT with or without concurrent chemotherapy at a single institution were identified and their records reviewed. A total of 51 patients were treated with RT alone; 20 patients were treated with CRT. Recurrences were analyzed. Overall survival (OS and disease-free survival (DFS rates were estimated using the Kaplan-Meier method. Cox regression analysis was performed. RESULTS: The median age at diagnosis was 61 years (range, 18-92 years and the median follow-up time among survivors was 3.0 years. Kaplan-Meier estimates for OS and DFS differed significantly between the RT and CRT groups (3-yr OS = 56% vs. 79%, log-rank p = 0.037; 3-yr DFS = 43% vs. 73%, log-rank p = 0.011. Twenty-three patients (45% in the RT group had a relapse at any site compared to 3 (15% in the CRT group (p = 0.027. With regard to the sites of first relapse, 10 patients (14% had local only, 4 (6% had local and regional, 9 (13% had regional only, 1 (1% had regional and distant, and 2 (3% had distant only relapse. On univariate analysis, the use of concurrent chemotherapy, FIGO stage, tumor size, and date of diagnosis were significant predictors of DFS. On multivariate analysis, the use of concurrent chemotherapy remained a significant predictor of DFS (hazard ratio 0.31 (95% CI, 0.10-0.97; p = 0.04. CONCLUSIONS: Vaginal cancer results in poor outcomes. Adequate radiation dose is essential to ensure curative management. Concurrent chemotherapy should be considered for vaginal cancer patients.

  8. Californium-252 Brachytherapy Combined With External-Beam Radiotherapy for Cervical Cancer: Long-Term Treatment Results

    International Nuclear Information System (INIS)

    Lei Xin; Qian Chengyuan; Qing Yi; Zhao Kewei; Yang Zhengzhou; Dai Nan; Zhong Zhaoyang; Tang Cheng; Li Zheng; Gu Xianqing; Zhou Qian; Feng Yan; Xiong Yanli; Shan Jinlu; Wang Dong

    2011-01-01

    Purpose: To observe, by retrospective analysis, the curative effects and complications due to californium-252 ( 252 Cf) neutron intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT) in the treatment of cervical cancer. Methods and Materials: From February 1999 to December 2007, 696 patients with cervical cancer (Stages IB to IIIB) were treated with 252 Cf-ICBT in combination of EBRT. Of all, 31 patients were at Stage IB, 104 at IIA, 363 at IIB, 64 at IIIA, and 134 at IIIB. Californium-252 ICBT was delivered at 7–12 Gy per insertion per week, with a total dose of 29–45 Gy to reference point A in three to five insertions. The whole pelvic cavity was treated with 8-MV X-ray external irradiation at 2 Gy per fraction, four times per week. After 16–38 Gy of external irradiation, the center of the whole pelvic field was blocked with a 4-cm-wide lead shield, with a total external irradiation dose of 44–56 Gy. The total treatment course was 5 to 6 weeks. Results: Overall survival rate at 3 and 5 years for all patients was 76.0% and 64.9%, respectively. Disease-free 3- and 5-year survival rates of patients were 71.2% and 58.4%, respectively. Late complications included vaginal contracture and adhesion, radiation proctitis, radiation cystitis, and inflammatory bowel, which accounted for 5.8%, 7.1%, 6.2%, and 4.9%, respectively. Univariate analysis results showed significant correlation of stage, age, histopathologic grade, and lymph node status with overall survival. Cox multiple regression analysis showed that the independent variables were stage, histopathologic grade, tumor size, and lymphatic metastasis in all patients. Conclusion: Results of this series suggest that the combined use of 252 Cf-ICBT with EBRT is an effective method for treatment of cervical cancer.

  9. Californium-252 Brachytherapy Combined With External-Beam Radiotherapy for Cervical Cancer: Long-Term Treatment Results

    Energy Technology Data Exchange (ETDEWEB)

    Lei Xin; Qian Chengyuan; Qing Yi; Zhao Kewei; Yang Zhengzhou; Dai Nan; Zhong Zhaoyang; Tang Cheng; Li Zheng; Gu Xianqing; Zhou Qian; Feng Yan; Xiong Yanli; Shan Jinlu [Cancer Center, Research Institute of Surgery and Daping Hospital, Third Military Medical University, Chongqing (China); Wang Dong, E-mail: dongwang64@hotmail.com [Cancer Center, Research Institute of Surgery and Daping Hospital, Third Military Medical University, Chongqing (China)

    2011-12-01

    Purpose: To observe, by retrospective analysis, the curative effects and complications due to californium-252 ({sup 252}Cf) neutron intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT) in the treatment of cervical cancer. Methods and Materials: From February 1999 to December 2007, 696 patients with cervical cancer (Stages IB to IIIB) were treated with {sup 252}Cf-ICBT in combination of EBRT. Of all, 31 patients were at Stage IB, 104 at IIA, 363 at IIB, 64 at IIIA, and 134 at IIIB. Californium-252 ICBT was delivered at 7-12 Gy per insertion per week, with a total dose of 29-45 Gy to reference point A in three to five insertions. The whole pelvic cavity was treated with 8-MV X-ray external irradiation at 2 Gy per fraction, four times per week. After 16-38 Gy of external irradiation, the center of the whole pelvic field was blocked with a 4-cm-wide lead shield, with a total external irradiation dose of 44-56 Gy. The total treatment course was 5 to 6 weeks. Results: Overall survival rate at 3 and 5 years for all patients was 76.0% and 64.9%, respectively. Disease-free 3- and 5-year survival rates of patients were 71.2% and 58.4%, respectively. Late complications included vaginal contracture and adhesion, radiation proctitis, radiation cystitis, and inflammatory bowel, which accounted for 5.8%, 7.1%, 6.2%, and 4.9%, respectively. Univariate analysis results showed significant correlation of stage, age, histopathologic grade, and lymph node status with overall survival. Cox multiple regression analysis showed that the independent variables were stage, histopathologic grade, tumor size, and lymphatic metastasis in all patients. Conclusion: Results of this series suggest that the combined use of {sup 252}Cf-ICBT with EBRT is an effective method for treatment of cervical cancer.

  10. Californium-252 brachytherapy combined with external-beam radiotherapy for cervical cancer: long-term treatment results.

    Science.gov (United States)

    Lei, Xin; Qian, Cheng-Yuan; Qing, Yi; Zhao, Ke-Wei; Yang, Zheng-Zhou; Dai, Nan; Zhong, Zhao-Yang; Tang, Cheng; Li, Zheng; Gu, Xian-Qing; Zhou, Qian; Feng, Yan; Xiong, Yan-Li; Shan, Jin-Lu; Wang, Dong

    2011-12-01

    To observe, by retrospective analysis, the curative effects and complications due to californium-252 (252Cf) neutron intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT) in the treatment of cervical cancer. From February 1999 to December 2007, 696 patients with cervical cancer (Stages IB to IIIB) were treated with 252Cf-ICBT in combination of EBRT. Of all, 31 patients were at Stage IB, 104 at IIA, 363 at IIB, 64 at IIIA, and 134 at IIIB. Californium-252 ICBT was delivered at 7-12 Gy per insertion per week, with a total dose of 29-45 Gy to reference point A in three to five insertions. The whole pelvic cavity was treated with 8-MV X-ray external irradiation at 2 Gy per fraction, four times per week. After 16-38 Gy of external irradiation, the center of the whole pelvic field was blocked with a 4-cm-wide lead shield, with a total external irradiation dose of 44-56 Gy. The total treatment course was 5 to 6 weeks. Overall survival rate at 3 and 5 years for all patients was 76.0% and 64.9%, respectively. Disease-free 3- and 5-year survival rates of patients were 71.2% and 58.4%, respectively. Late complications included vaginal contracture and adhesion, radiation proctitis, radiation cystitis, and inflammatory bowel, which accounted for 5.8%, 7.1%, 6.2%, and 4.9%, respectively. Univariate analysis results showed significant correlation of stage, age, histopathologic grade, and lymph node status with overall survival. Cox multiple regression analysis showed that the independent variables were stage, histopathologic grade, tumor size, and lymphatic metastasis in all patients. Results of this series suggest that the combined use of 252Cf-ICBT with EBRT is an effective method for treatment of cervical cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. External-beam PIXE characterization of volcanic material used in ancient Roman mortars

    International Nuclear Information System (INIS)

    Sonck-Koota, P.; Lindroos, A.; Lill, J.-O.; Rajander, J.; Viitanen, E.-M.; Marra, F.; Pehkonen, M.H.; Suksi, J.; Heselius, S.-J.

    2008-01-01

    Volcanic deposits from two volcanic districts, Monti Sabatini (MSVD) and Colli Albani (CAVD), NW and SE of Rome, were analyzed using the particle-induced X-ray emission (PIXE) technique, in order to obtain chemical fingerprints that can be used for provenance studies of filler materials in ancient Roman mortars. The rock samples were mounted on an X-Y stage enabling scanning over the sample surface and irradiated in air with a collimated 3 MeV proton beam. The samples were either analyzed by scanning the beam over a polished surface or they were crushed, ground and homogenized prior to the irradiation. However, scanning over polished sample surfaces avoiding heterogeneities gave quite similar results as scanning over pellet surfaces, especially for the minor and trace elements. This study shows that the deposits of MSVD and CAVD can be distinguished from each other. Several elements or elemental ratios can be used to characterize the districts. Even the individual volcanic deposits of CAVD can be identified

  12. The use of Monte-Carlo codes for treatment planning in external-beam radiotherapy

    International Nuclear Information System (INIS)

    Alan, E.; Nahum, PhD.

    2003-01-01

    Monte Carlo simulation of radiation transport is a very powerful technique. There are basically no exact solutions to the Boltzmann transport equation. Even, the 'straightforward' situation (in radiotherapy) of an electron beam depth-dose distribution in water proves to be too difficult for analytical methods without making gross approximations such as ignoring energy-loss straggling, large-angle single scattering and Bremsstrahlung production. monte Carlo is essential when radiation is transport from one medium into another. As the particle (be it a neutron, photon, electron, proton) crosses the boundary then a new set of interaction cross-sections is simply read in and the simulation continues as though the new medium were infinite until the next boundary is encountered. Radiotherapy involves directing a beam of megavoltage x rays or electrons (occasionally protons) at a very complex object, the human body. Monte Carlo simulation has proved in valuable at many stages of the process of accurately determining the distribution of absorbed dose in the patient. Some of these applications will be reviewed here. (Rogers and al 1990; Andreo 1991; Mackie 1990). (N.C.)

  13. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.

    Science.gov (United States)

    Hoffman, David; Chung, Eunah; Hess, Clayton; Stern, Robin; Benedict, Stanley

    2017-01-01

    The aim of this work was to comprehensively evaluate a new large field ion chamber transmission detector, Integral Quality Monitor (IQM), for online external photon beam verification and quality assurance. The device is designed to be mounted on the linac accessory tray to measure and verify photon energy, field shape, gantry position, and fluence before and during patient treatment. Our institution evaluated the newly developed ion chamber's effect on photon beam fluence, response to dose, detection of photon fluence modification, and the accuracy of the integrated barometer, thermometer, and inclinometer. The detection of photon fluence modifications was performed by measuring 6 MV with fields of 10 cm × 10 cm and 1 cm × 1 cm "correct" beam, and then altering the beam modifiers to simulate minor and major delivery deviations. The type and magnitude of the deviations selected for evaluation were based on the specifications for photon output and MLC position reported in AAPM Task Group Report 142. Additionally, the change in ion chamber signal caused by a simulated IMRT delivery error is evaluated. The device attenuated 6 MV, 10 MV, and 15 MV photon beams by 5.43 ± 0.02%, 4.60 ± 0.02%, and 4.21 ± 0.03%, respectively. Photon beam profiles were altered with the IQM by < 1.5% in the nonpenumbra regions of the beams. The photon beam profile for a 1 cm × 1 cm 2 fields were unchanged by the presence of the device. The large area ion chamber measurements were reproducible on the same day with a 0.14% standard deviation and stable over 4 weeks with a 0.47% SD. The ion chamber's dose-response was linear (R 2 = 0.99999). The integrated thermometer agreed to a calibrated thermometer to within 1.0 ± 0.7°C. The integrated barometer agreed to a mercury barometer to within 2.3 ± 0.4 mmHg. The integrated inclinometer gantry angle measurement agreed with the spirit level at 0 and 180 degrees within 0.03 ± 0.01 degrees and 0.27 ± 0.03 at 90 and 270 degrees. For the

  14. External audit on output calibration for photon beams (Polish participation in pan-European Radiation Oncology Project for Assurance of Treatment Quality)

    Energy Technology Data Exchange (ETDEWEB)

    Izewska, J.; Rostkowska, J.; Kania, M.; Gwiazdowska, B.; Hliniak, A. [Instytut Onkologii, Warsaw (Poland)

    1995-12-31

    TLD audit of photon beams in radiotherapy centres started in June 1994 within the frame of the EROPAQ project. All 55 photon beams in Polish departments have been checked and 18 beams rechecked in the centres , where deviations out of 3% were detected. Out of 55 beams checked in the first run, 87% were found within 3% acceptance limit and 13% showed deviations larger than 3%. No deviations out of 6% have been detected. The results of the national intercomparison for photon beams (90-92) compared to the results of the EROPAQ audit (94-95) show an improvement of the beam calibrations in Poland and illustrate the usefulness of external audits. (author). 15 refs, 3 figs, 3 tabs.

  15. An overview of current practice in external beam radiation oncology with consideration to potential benefits and challenges for nanotechnology.

    Science.gov (United States)

    King, Raymond B; McMahon, Stephen J; Hyland, Wendy B; Jain, Suneil; Butterworth, Karl T; Prise, Kevin M; Hounsell, Alan R; McGarry, Conor K

    2017-01-01

    Over the past two decades, there has been a significant evolution in the technologies and techniques employed within the radiation oncology environment. Over the same period, extensive research into the use of nanotechnology in medicine has highlighted a range of potential benefits to its incorporation into clinical radiation oncology. This short communication describes key tools and techniques that have recently been introduced into specific stages of a patient's radiotherapy pathway, including diagnosis, external beam treatment and subsequent follow-up. At each pathway stage, consideration is given towards how nanotechnology may be combined with clinical developments to further enhance their benefit, with some potential opportunities for future research also highlighted. Prospective challenges that may influence the introduction of nanotechnology into clinical radiotherapy are also discussed, indicating the need for close collaboration between academic and clinical staff to realise the full clinical benefit of this exciting technology.

  16. Statistical modeling of the eye for multimodal treatment planning for external beam radiation therapy of intraocular tumors.

    Science.gov (United States)

    Rüegsegger, Michael B; Bach Cuadra, Meritxell; Pica, Alessia; Amstutz, Christoph A; Rudolph, Tobias; Aebersold, Daniel; Kowal, Jens H

    2012-11-15

    Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Cross-validation revealed a dice similarity of 95%±2% for the sclera and cornea and 91%±2% for the lens. Overall, mean segmentation error was found to be 0.3±0.1 mm. Average segmentation time was 14±2 s on a standard personal computer. Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. External Beam Irradiation and Restenosis Following Femoral Stenting: Long-Term Results of a Prospective Randomized Study

    International Nuclear Information System (INIS)

    Zampakis, Petros; Karnabatidis, Dimitrios; Kalogeropoulou, Christina; Kardamakis, Dimitrios M.; Katsanos, Konstantinos; Skouras, Theodoros; Siablis, Dimitrios

    2007-01-01

    Purpose. To assess the long-term outcome of external beam irradiation (EBI) for the prevention of restenosis due to neointimal hyperplasia, following percutaneous transluminal angioplasty (PTA) and stenting of the superficial femoral artery. Methods. Sixty consecutive patients with peripheral arterial disease, who were treated with 'bail-out' stent implantation in the superficial femoral artery due to suboptimal PTA, were included in this study. Patients were randomly allocated into two groups, receiving either external beam irradiation (6 MV photons, total dose 24 Gy in a hypofractionated schedule) plus antiplatelet therapy (EBI group) or antiplatelet therapy alone (control group). Results. No procedure-related complications occurred, and all patients of the EBI group received the full dose of 24 Gy. During the long-term follow-up, an overall statistically significant difference was demonstrated in favor of the EBI group patients, regarding both the in-stent (log-rank test, p = 0.0072) and the in-segment binary restenosis (log-rank test, p = 0.0103). The primary patency rates were also significantly better in the EBI group at specific time-points, such as in the first (74.2% vs 46.5%, p = 0.019), second (62.5% vs 33.8%, p = 0.020), and third (54.6% vs 29.0%, p = 0.039) year, respectively. Moreover, the overall clinically driven reintervention rate was significantly lower among patients of the irradiated group (log-rank test, p = 0.038). Conclusion. Our long-term follow-up analysis revealed that EBI following femoral artery PTA and stenting significantly reduces restenosis and reintervention rates, while improving primary patency

  18. Statistical Modeling of the Eye for Multimodal Treatment Planning for External Beam Radiation Therapy of Intraocular Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rueegsegger, Michael B. [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland); Bach Cuadra, Meritxell [Department of Radiology, University Hospital Center (CHUV) and University of Lausanne (UNIL), Signal Processing Laboratory - LTS5, Ecole Polytechnique Federale de Lausanne (Switzerland); Pica, Alessia [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Amstutz, Christoph A. [Department of Ophthalmology, University Hospital Zurich (Switzerland); Rudolph, Tobias [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland); Aebersold, Daniel [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Kowal, Jens H., E-mail: jens.kowal@artorg.unibe.ch [ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland)

    2012-11-15

    Purpose: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Methods and Materials: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Results: Cross-validation revealed a dice similarity of 95% {+-} 2% for the sclera and cornea and 91% {+-} 2% for the lens. Overall, mean segmentation error was found to be 0.3 {+-} 0.1 mm. Average segmentation time was 14 {+-} 2 s on a standard personal computer. Conclusions: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

  19. Phase II study of concurrent capecitabine and external beam radiotherapy for pain control of bone metastases of breast cancer origin.

    Directory of Open Access Journals (Sweden)

    Yulia Kundel

    Full Text Available Pain from bone metastases of breast cancer origin is treated with localized radiation. Modulating doses and schedules has shown little efficacy in improving results. Given the synergistic therapeutic effect reported for combined systemic chemotherapy with local radiation in anal, rectal, and head and neck malignancies, we sought to evaluate the tolerability and efficacy of combined capecitabine and radiation for palliation of pain due to bone metastases from breast cancer.Twenty-nine women with painful bone metastases from breast cancer were treated with external beam radiation in 10 fractions of 3 Gy, 5 fractions a week for 2 consecutive weeks. Oral capecitabine 700 mg/m(2 twice daily was administered throughout radiation therapy. Rates of complete response, defined as a score of 0 on a 10-point pain scale and no increase in analgesic consumption, were 14% at 1 week, 38% at 2 weeks, 52% at 4 weeks, 52% at 8 weeks, and 48% at 12 weeks. Corresponding rates of partial response, defined as a reduction of at least 2 points in pain score without an increase in analgesics consumption, were 31%, 38%, 28%, 34% and 38%. The overall response rate (complete and partial at 12 weeks was 86%. Side effects were of mild intensity (grade I or II and included nausea (38% of patients, weakness (24%, diarrhea (24%, mucositis (10%, and hand and foot syndrome (7%.External beam radiation with concurrent capecitabine is safe and tolerable for the treatment of pain from bone metastases of breast cancer origin. The overall and complete response rates in our study are unusually high compared to those reported for radiation alone. Further evaluation of this approach, in a randomized study, is warranted.ClinicalTrials.gov NCT01784393NCT01784393.

  20. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor

    2005-01-01

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  1. Second malignancies following conventional or combined 252Cf neutron brachytherapy with external beam radiotherapy for breast cancer

    Science.gov (United States)

    Valuckas, Konstantinas Povilas; Atkocius, Vydmantas; Kuzmickiene, Irena; Aleknavicius, Eduardas; Liukpetryte, Sarune; Ostapenko, Valerijus

    2013-01-01

    We retrospectively evaluated the risk of second malignancies among 832 patients with inner or central breast cancer treated with conventional external beam schedule (CRT group), or neutron brachytherapy using Californium-252 (252Cf) sources and hypofractionated external beam radiotherapy (HRTC group), between 1987 and 1996 at the Institute of Oncology, Vilnius University. Patients were observed until the occurrences of death or development of a second malignancy, or until 31 December 2009, whichever was earlier. Median follow-up time was 10.4 years (range, 1.2–24.1 years). Risk of second primary cancers was quantified using standardized incidence ratios (SIRs). Cox proportional hazards regression models were used to estimate hazard ratios (HRs). There was a significant increase in the risk of second primary cancers compared with the general population (SIR 1.3, 95% CI 1.1–1.5). The observed number of second primary cancers was also higher than expected for breast (SIR 1.8, 95% CI 1.3–2.4) and lung cancer (SIR 3.8, 95% CI 2.0–6.7). For second breast cancer, no raised relative risk was observed during the period ≥10 or more years after radiotherapy. Compared with the CRT group, HRTC patients had a not statistically significant higher risk of breast cancer. Increased relative risks were observed specifically for age at initial diagnosis of <50 years (HR 2.9, 95% CI 1.6–5.2) and for obesity (HR 2.8, 95% CI 1.1–7.2). PMID:23397075

  2. Characterization of the Teotihuacan mural painting: application of the external particle beam as non destructive technique

    International Nuclear Information System (INIS)

    Martinez, C.; Manzanilla, L.; Ruvalcaba, J.L.; Ontalba, M.A.

    2005-01-01

    The characterization of technical indicators contained in the painting mural should follow a minim methodology from their discovery in the archaeological excavations until their analysis in the laboratory, with the purpose of rescuing diagnostic elements that mark the stages of socio cultural development in the towns. With this spirit it was carried out the present study analyzing some fragments of the Teotihuacan mural painting. The analysis consisted on applying some of the analytical techniques with particle beams used for archaeometry like the Proton induced X-ray emission (PIXE) and the particle elastic backscattering (RBS), due to it is treated of complementary techniques, very sensitive, of multielemental character, but mainly because its are non destructive analytical techniques. (Author)

  3. Coupled PIXE and RBS using a 6MeV 4He2+ external beam: A new experimental device for particle detection and dose monitoring

    International Nuclear Information System (INIS)

    Mathis, F.; Moignard, B.; Pichon, L.; Dubreuil, O.; Salomon, J.

    2005-01-01

    AGLAE (Accelerateur Grand Louvre d'Analyses Elementaire), the IBA facility of the 'Centre de Recherche et de Restauration des Musees de France' (C2RMF) has been equipped for several years with an external micro-beam line, in order to perform ion beam analysis on materials relevant to cultural heritage. This beam line is undergoing constant improvement. Recently, a new extraction nozzle for the external beam of the accelerator has been designed in order to obtain simultaneously from the same spot: - detection of the X-ray emission by two detectors, for low and high energies; - detection of the backscattered particles for a backscattering angle between 170 and 175 deg., thanks to an annular surface barrier detector included in the nozzle; - particle current monitoring by intermittent beam deflection on a reference material included in the system. This technical development has been induced by the study of artificial patinas on archaeological copper-alloy objects and the attempt to characterize them with a 6MeV 4 He 2+ beam, an unusual beam for this type of investigation. A detailed description of the new device and some results on an application of the use of high-energy alpha beam in PIXE and RBS made on a Roman strigil are presented here

  4. Adjuvant external beam radiotherapy in the treatment of endometrial cancer (MRC ASTEC and NCIC CTG EN.5 randomised trials): pooled trial results, systematic review, and meta-analysis.

    Science.gov (United States)

    Blake, P; Swart, Ann Marie; Orton, J; Kitchener, H; Whelan, T; Lukka, H; Eisenhauer, E; Bacon, M; Tu, D; Parmar, M K B; Amos, C; Murray, C; Qian, W

    2009-01-10

    Early endometrial cancer with low-risk pathological features can be successfully treated by surgery alone. External beam radiotherapy added to surgery has been investigated in several small trials, which have mainly included women at intermediate risk of recurrence. In these trials, postoperative radiotherapy has been shown to reduce the risk of isolated local recurrence but there is no evidence that it improves recurrence-free or overall survival. We report the findings from the ASTEC and EN.5 trials, which investigated adjuvant external beam radiotherapy in women with early-stage disease and pathological features suggestive of intermediate or high risk of recurrence and death from endometrial cancer. Between July, 1996, and March, 2005, 905 (789 ASTEC, 116 EN.5) women with intermediate-risk or high-risk early-stage disease from 112 centres in seven countries (UK, Canada, Poland, Norway, New Zealand, Australia, USA) were randomly assigned after surgery to observation (453) or to external beam radiotherapy (452). A target dose of 40-46 Gy in 20-25 daily fractions to the pelvis, treating five times a week, was specified. Primary outcome measure was overall survival, and all analyses were by intention to treat. These trials were registered ISRCTN 16571884 (ASTEC) and NCT 00002807 (EN.5). After a median follow-up of 58 months, 135 women (68 observation, 67 external beam radiotherapy) had died. There was no evidence that overall survival with external beam radiotherapy was better than observation, hazard ratio 1.05 (95% CI 0.75-1.48; p=0.77). 5-year overall survival was 84% in both groups. Combining data from ASTEC and EN.5 in a meta-analysis of trials confirmed that there was no benefit in terms of overall survival (hazard ratio 1.04; 95% CI 0.84-1.29) and can reliably exclude an absolute benefit of external beam radiotherapy at 5 years of more than 3%. With brachytherapy used in 53% of women in ASTEC/EN.5, the local recurrence rate in the observation group at 5 years

  5. An external proton beam at VERA to study objects of art by proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Kroepfl, P.; Forstner, O.; Kutschera, W.; Priller, A.; Steier, P.; Wallner, A.; Wuenschek, B.; Golser, R.

    2006-01-01

    Full text: PIXE is a very sensitive analytical method to determine the chemical composition of art objects, e.g. drawings, handwritings etc. A particular advantage is the possibility to analyze objects non-destructively under atmospheric pressure. Such an external beam PIXE facility is currently implemented at the Vienna Environmental Research Accelerator (VERA). The set-up allows to extract a 3 MeV proton beam of approximately 100 μm in diameter and currents in the range of a few nA's through an ultra-thin (0.1 μm) Silicon Nitride window. The characteristic x-rays emitted from the specimen are recorded with a Si(Li) and a Silicon Drift detector simultaneously to cover the widest possible Z-range of the detected elements. We have just completed an extensive period of studying beam effects on ancient paper to exclude possible damage to art objects, in particular drawings of the Renaissance that are among the most precious and rarest treasuries of graphical collections. They were created with different materials such as inks, chalks and metal points. A large collection of these fine arts objects is situated at the Albertina in Vienna. Together with scientists from the Centre de Recherche et de Restauration des Musees de France (C2RMF) in Paris, I. Reiche, A. Duval, H. Guicharnaud, from the CEREGE UMR CNRS 6635 in Aix-en-Provence, S. Merchel, from the Albertina in Vienna, E. Thobois, H. Singer, and from the Akademie der bildenden Kuenste in Vienna, M. Schreiner, we want then to analyze a few selected silverpoint drawings by Albrecht Duerer (1471-1528). (author)

  6. Comparative study of cone beam computed tomography and intraoral periapical radiographs in diagnosis of lingual-simulated external root resorptions.

    Science.gov (United States)

    Bernardes, Ricardo Affonso; de Paulo, Renata Silvéria; Pereira, Luciana Oliveira; Duarte, Marco Antonio Hungaro; Ordinola-Zapata, Ronald; de Azevedo, José Ribamar

    2012-08-01

    Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. The goal of this study was to compare two image acquisition methods, intraoral radiographs and cone beam computed tomography (CBCT), in the diagnosis of external resorption. Thirty-four maxillary and mandibular bicuspids were divided into three groups. Perforations measuring 0.3 and 0.6 mm in diameter and 0.15 and 0.3 mm in depth, respectively, were made on the lingual root surfaces in thirty teeth, and four were used as controls. Next, teeth were mounted on an apparatus and radiographed at mesial, distal, and orthoradial angulations. CBCT images were also taken. The analysis of the intraoral radiographic and tomographic images was carried out by two experts using standardized scores. Data were then compared statistically. A strong agreement between the examiners was observed in both diagnosis methods, the intraoral radiographic (r = 0.93) and the tomographic analysis (r = 1.0). Tomography had higher statistically significant detection values than intraoral radiography (P radiography was significantly higher than that of 0.3-mm perforations (P radiography, regardless of the tooth or the dimensions of the resorption evaluated. © 2012 John Wiley & Sons A/S.

  7. Normal tissue tolerance to external beam radiation therapy: Thyroid; Dose de tolerance des tissus sains: la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Berges, O.; Giraud, P. [Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, universite Paris Descartes, 75 - Paris (France); Belkacemi, Y. [Service d' oncologie-radiotherapie, CHU Henri-Mondor, universite Paris 12, 94 - Creteil (France)

    2010-07-15

    The thyroid is the most developed endocrine gland of the body. Due to its anatomical location, it may be exposed to ionizing radiation in external radiotherapy involving head and neck. This review aims to describe the thyroid radiation disorders, probably under-reported in the literature, their risk factors and follow-up procedures. The functional changes after external beam radiation consists mainly of late effects occurring beyond 6 months, and are represented by the clinical and subclinical hypothyroidism. Its incidence is approximately 20 to 30% and it can occur after more than 25 years after radiation exposure. Hyperthyroidism and auto-immune manifestations have been described in a lesser proportion. The morphological changes consist of benign lesions, primarily adenomas, and malignant lesions, the most feared and which incidence is 0.35%. The onset of hypothyroidism depends of the total dose delivered to the gland, and the irradiated. Modern techniques of conformal radiotherapy with modulated intensity could improve the preservation of the thyroid, at the expense of the increase in low doses and the theoretical risk of secondary cancers. (authors)

  8. The influence of single and fractionated dose external beam irradiation on injury-induced arterial smooth muscle cell proliferation

    International Nuclear Information System (INIS)

    Schaefer, U.; Micke, O.; Dorszewski, A.; Breithardt, G.; Willich, N.

    1997-01-01

    Purpose/Objective: Restenosis after catheter-based revascularization has been demonstrated to be primarily caused by smooth muscle cell proliferation. This study examined the effects of external beam irradiation on neointimal proliferation after external injury to the central artery of the rabbit ear. Materials and Methods: 40 male New Zealand White rabbits were used in this study. Crush lesions were performed on each ear under general anesthesia and bilateral auricular nerve blockade. A single dose of 12 Gy (n=10), 16 Gy (n=10), or 20 Gy (n=10) and a fractionated dose of 4 x 5 Gy (n=10) gamma radiation was delivered to the left or right central artery of the ear 24 hours after injury; the contralateral central artery served as control. All rabbits were sacrificed after twenty-one days and the central arteries of the ear were fixed for morphometric measurements. Results: Mean (± SD) neointimal area was 0.062 ± 0.005 mm 2 (12 Gy), 0.022 ± 0,005 mm 2 (16 Gy), 0,028 ± 0,006 mm 2 and 0.038 mm 2 ± 0,02 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,081 ± 0,009 mm 2 in the control group. Mean (±SD) luminal area was 0.049 ± 0.004 mm 2 (12 Gy), 0.059 ± 0.002 mm 2 (16 Gy), 0.072 ± 0,006 mm 2 (20 Gy) and 0.048 mm 2 ± 0,018 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,043 ± 0,008 mm 2 in the control group. The difference in neointimal and luminal area between control and irradiated arteries was significant (p<0.05) only for the 16 and 20 Gy group compared to control. Conclusion: We conclude that in this model, external beam X-ray irradiation was successful in reducing neointimal proliferation after injury of the central artery of the rabbit ear. The optimal dose seems to be a single dose of 16 Gy - 20 Gy. Only a less prominent effect was noted for a fractionated dose of 4 x 5 Gy. Whether this approach can be used successfully to inhibit restenosis in the clinical setting requires further investigation

  9. Organ/patient geometric variation in external beam radiotherapy and its effects

    International Nuclear Information System (INIS)

    Yan Di; Lockman, David

    2001-01-01

    Treatment variation in positioning of the organ/patient with respect to the radiation beams causes a temporal dose variation in critical normal tissues adjacent to the treatment target. This temporal variation induces uncertainties in understanding the normal tissue dose response, thereby limiting reliable treatment evaluation and optimization. The aim of this study is to model and analyze the temporal variation of organ dose distribution, and its effect on the biological effective dose. The study mainly focuses on the temporal dose variation caused by intertreatment organ motion/deformation and daily setup error. Sensitivity of the biological effective dose to organ/patient geometric variation, dose distribution, and treatment fractionation will be investigated. Significant deviation of the biological effective dose could be expected in a critical normal structure, even if the cumulative dose deviation in this structure is negligible. Patients with similar geometric variation characteristics can experience significantly different biological effective dose, and the differences are sensitive to the dose distribution and the total number of treatment fractions

  10. Change in volume of lumpectomy cavity during external-beam irradiation of the intact breast

    International Nuclear Information System (INIS)

    Jacobson, Geraldine; Betts, Vicki; Smith, Brian

    2006-01-01

    Purpose: Definition of the lumpectomy cavity is an important component of irradiation of the breast. We use computed tomography (CT)-based planning and contour the lumpectomy volume on the planning CT. We obtained a second CT in the 4th or 5th week of treatment for boost planning and compared the volume change with the first planning-CT scan. Methods and Materials: This retrospective study reviewed the planning-CT data for 20 patients. In the first CT, images were obtained from the mandible to 2 cm below the breast in 3-mm slices. In the second CT, for the boost, images were obtained from the top to the bottom of the clinically defined breast, in 3-mm slices. Lumpectomy cavities were contoured on both CT scans and volumes compared. Results: Sixteen of the 20 patients (80%) had more than a 20% decrease from the first to the second volume, with a corresponding 95% confidence interval. The mean decrease was 16.13 cc, with a standard deviation of 14.05. The Spearman correlation coefficient of 0.18 did not show a significant correlation between the initial volume and the percent change. Conclusions: During external breast irradiation, many patients will have significant volume reduction in the lumpectomy cavity. Because CT-based definition of the lumpectomy cavity can influence the planning of a boost technique, further study appears warranted

  11. Deformable and posture-changeable computational phantoms and dosimetry data for standard external-beam irradiations

    International Nuclear Information System (INIS)

    Zhang, J.; Na, Y. H.; Ding, A.; Xu, X. G.

    2009-01-01

    For many radiation dosimetry studies, whole-body phantoms representing workers and patients are used to perform Monte Carlo calculations of organ doses. Since the 1960's, approximately 121 computational phantoms have been reported in the literatures for studies involving ionizing and non-ionizing radiations. There is a barrier currently in developing and in applying person-specific phantoms that are anatomically different from the ICRP reference individuals. We recently adopted the novel-surface modeling method to systematically design a set of pregnant female phantoms by manual work. Now, the automatically algorithm has been systematically developed to develop computational human phantom by all mesh-based organ files. Using this approach we have now developed a pair of mesh-based adult phantoms, RPI-AM and RP1-AF, representing ICRP 89 50.-percentile adult males and adult females. A software has also been developed to develop the phantoms representing different percentile populations and different postures based on this pair of phantoms. The absorbed organ dose results for the external photon exposures using this pair of phantoms were calculated and compared with the ICRP Phantoms. These results demonstrated that, although both sets of phantoms have the same organ volumes and masses, the anatomical differences can cause to dosimetry differences in terms of the effective doses as well as organ absorbed doses. The posture-changing ability has potential applications in many areas of radiation dosimetry. (authors)

  12. Phase II Study of Consolidation Chemotherapy After Concurrent Chemoradiation in Cervical Cancer: Preliminary Results

    International Nuclear Information System (INIS)

    Choi, Chel Hun; Lee, Jeong-Won; Kim, Tae-Joong; Kim, Woo Young; Nam, Hee Rim; Kim, Byoung-Gie; Huh, Seung Jae; Lee, Je-Ho; Bae, Duk-Soo

    2007-01-01

    Purpose: Our aim was to determine the efficacy of consolidation chemotherapy after concurrent chemoradiation (CCRT) using high-dose-rate brachytherapy in patients with locally advanced cervical carcinoma. Methods and Materials: Patients with cervical carcinoma (FIGO stage IB2-IVA) were treated with external beam radiation therapy to the whole pelvis (50.4 Gy) and high-dose-rate brachytherapy (24 Gy to point A). Cisplatin 60 mg/m 2 (Day 1) and 5-fluorouracil 1000 mg/m 2 (Days 1-5) were given every 3 weeks starting concurrently with the radiation and followed by 3 more cycles of consolidation for a total of 6 cycles. Results: Thirty patients (94%) received 3 more cycles of post-CCRT consolidation chemotherapy and were evaluable for the toxicity and efficacy of consolidation. The most common toxicities of Grade 2 or higher were nausea or vomiting (47%) and anemia (33%). Late complications of the rectum and bladder occurred in 13% and 6% of the patients, respectively. The clinical complete response rate was 87% (95% CI, 75%-99%). During a median follow-up of 27 months (range, 6-58 months), 5 patients (17%) had recurrence; the sites of failure were 3 (10%) inside the radiation field and 2 (7%) outside the radiation field. The estimated 3-year progression-free survival rate was 83% (95% CI, 67%-99%) and overall survival rate was 91% (95% CI, 79%-100%). Conclusions: Consolidation chemotherapy after CCRT is well tolerated and effective in patients with locally advanced cervical carcinoma. A prospective randomized trial to compare this treatment strategy with standard CCRT seems to be worthwhile

  13. Cervical necrosis after chemoradiation for cervical cancer: case series and literature review

    International Nuclear Information System (INIS)

    Fawaz, Ziad Simon; Barkati, Maroie; Beauchemin, Marie-Claude; Sauthier, Philippe; Gauthier, Philippe; Nguyen, Thu Van

    2013-01-01

    The aim of this study was to assess the management of cervical necrosis (CN) following radiotherapy (RT) and the impact of smoking status. This rare complication mimics a neoplastic recurrence, and causes concern among attending physicians. Between July 2008 and March 2013, 5 women on 285 with localized cervical cancer had a CN following RT. Patients were treated with concomitant chemoradiation. The medical records were reviewed to abstract demographic and clinical information until March 2013. 1.75% (95% confidence interval: 0.23 to 3.28%) developed CN. All patients were smokers with a mean of 19.5 pack-years (range: 7.5-45 pack-years). All patients were treated with weekly Cisplatin chemotherapy and external beam radiation to the pelvis, 45 Gy in 25 fractions. Four patients received an extra boost with a median dose of 7.2 Gy (range: 5.4-10 Gy). All patients had intracavitary brachytherapy (range: 27.9 to 30 Gy). Clinical presentation was similar for all the cases: vaginal discharge associated with pain. Mean time for time post-radiation therapy to necrosis was 9.3 months (range: 2.2-20.5 months). Standard workup was done to exclude cancer recurrence: biopsies and radiologic imaging. Conservative treatment was performed with excellent results. Resolution of the necrosis was complete after a few months (range: 1 to 4 months). Median follow-up until March 2013 was 19 months. All the patients were alive with no clinical evidence of disease. This study, the largest to date, shows that conservative management of CN after RT is effective, and should be attempted. This complication is more common in smokers, and counseling intervention should result in fewer complications of CN

  14. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

    Science.gov (United States)

    Knöös, Tommy; Wieslander, Elinore; Cozzi, Luca; Brink, Carsten; Fogliata, Antonella; Albers, Dirk; Nyström, Håkan; Lassen, Søren

    2006-11-01

    A study of the performance of five commercial radiotherapy treatment planning systems (TPSs) for common treatment sites regarding their ability to model heterogeneities and scattered photons has been performed. The comparison was based on CT information for prostate, head and neck, breast and lung cancer cases. The TPSs were installed locally at different institutions and commissioned for clinical use based on local procedures. For the evaluation, beam qualities as identical as possible were used: low energy (6 MV) and high energy (15 or 18 MV) x-rays. All relevant anatomical structures were outlined and simple treatment plans were set up. Images, structures and plans were exported, anonymized and distributed to the participating institutions using the DICOM protocol. The plans were then re-calculated locally and exported back for evaluation. The TPSs cover dose calculation techniques from correction-based equivalent path length algorithms to model-based algorithms. These were divided into two groups based on how changes in electron transport are accounted for ((a) not considered and (b) considered). Increasing the complexity from the relatively homogeneous pelvic region to the very inhomogeneous lung region resulted in less accurate dose distributions. Improvements in the calculated dose have been shown when models consider volume scatter and changes in electron transport, especially when the extension of the irradiated volume was limited and when low densities were present in or adjacent to the fields. A Monte Carlo calculated algorithm input data set and a benchmark set for a virtual linear accelerator have been produced which have facilitated the analysis and interpretation of the results. The more sophisticated models in the type b group exhibit changes in both absorbed dose and its distribution which are congruent with the simulations performed by Monte Carlo-based virtual accelerator.

  15. Preoperative chemoradiation with cisplatin and 5-fluorouracil for extraperitoneal T3 rectal cancer: acute toxicity, tumor response, sphincter preservation

    International Nuclear Information System (INIS)

    Valentini, Vincenzo; Coco, Claudio; Cellini, Numa; Picciocchi, Aurelio; Rosetto, Maria Elena; Mantini, Giovanna; Marmiroli, Luca; Barbaro, Brunella; Cogliandolo, Santa; Nuzzo, Gennaro; Tedesco, Manfredo; Ambesi-Impiombato, Fabrizio; Cosimelli, Maurizio; Rotman, Marvin

    1999-01-01

    Purpose: To evaluate the impact of preoperative external radiation therapy intensified by systemic chemotherapy including bolus cisplatin (c-DDP) and 4-day infusional 5-fluorouracil (PLAFUR-4) on tumor response and sphincter preservation in patients with extraperitoneal T3 rectal cancer with acceptable toxicity, and to compare the results to our previous experience with bolus mitomycin c (MMC) and 4-day infusion 5-FU (FUMIR). Methods and Materials: Between October 1995 and March 1998, 40 consecutive patients with resectable extraperitoneal adenocarcinoma of the rectum were treated with preoperative chemoradiation: slow infusion iv c-DDP, 60 mg/m 2 , day 1 and 29 plus 24-h continuous infusion iv 5-fluorouracil (5-FU) 1000 mg/m 2 , days 1-4 and 29-32, and concurrent external beam radiotherapy (45 Gy whole pelvis followed by 5.4 Gy boost). All but 3 patients had T3 disease. Surgery was performed 6-8 weeks after the end of chemoradiation. Results: No patient had Grade 4 acute toxicity. Grade 3 hematological toxicity was observed only in 2 (5%) patients. No patient had major gastrointestinal, skin, or urological acute toxicity. All patients had radical surgery. There was no perioperative mortality; perioperative morbidity rate was 12%. Overall, 23% (9 of 40) of patients had a complete pathological response and 10% (4 of 40) of patients had rare isolated residual cancer cells (Tmic). Comparing the stage at the diagnostic workup with the pathological stage, tumor downstaging was observed in 27 (68%) patients; nodal status downstaging was detected in 24 (60%) patients. Thirty-four (85%) patients had a sphincter-saving surgical procedure. In 4 of 10 (40%) patients who were definitive candidates for an abdominoperineal resection (APR), the sphincter was preserved, as it was in 13 of 13 (100%) probable candidates. Lengthening of the distance between the anorectal ring and the lower pole of the tumor ≥ 20 mm was observed in 9 (23%) patients. None of the patients had soilage

  16. [Application of cone-beam computed tomography in the diagnosis and treatment of external root resorption of adjacent teeth caused by impacted teeth].

    Science.gov (United States)

    Li, Zhijin; Guo, Jiaping; Shi, Yongmei; Dong, Qingshan; Wang, Xiang; Xiong, Caihua; Gui, Xiao

    2013-12-01

    This study aims to investigate the diagnosis and treatment of external root resorption of adjacent teeth caused by impacted teeth via cone-beam computed tomography (CBCT). A total of 19 teeth from 15 patients with uncertain external root resorption caused by an adjacent impacted tooth were examined from January 2011 to December 2011. All teeth with uncertain external root resorption were scanned by CBCT. Three dimensions reconstruction were the conducted to determine the location and extent of resorption. In all cases, CBCT identified the accurate location and extent of external root resorption caused by adjacent impacted teeth. Furthermore, the technique provided impacted teeth location in three dimensions, including the relation between the impacted teeth and surrounding vital structures. CBCT can provide direct and accurate images of the location and extent of external root resorption, as well as the location of the adjacent impacted teeth in three dimensions. Therefore, the proposed technique provides reliable information for clinical diagnosis and treatment.

  17. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    International Nuclear Information System (INIS)

    Samea, Renato; Lourenco, Laercio Gomes

    2011-01-01

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  18. Successful treatment of a 67-year-old woman with urethral adenocarcinoma with the use of external beam radiotherapy and image guided adaptive interstitial brachytherapy

    DEFF Research Database (Denmark)

    Mujkanovic, Jasmin; Tanderup, Kari; Agerbæk, Mads

    2016-01-01

    Primary urethral cancer (PUC) is a very rare disease. This case report illustrates a successful treatment approach of a 67-year-old woman with a urethral adenocarcinoma selected for an organ preserving treatment with external beam radiotherapy (EBRT) and interstitial brachytherapy (BT) boost, using...

  19. Improving Outcome in Malignant Pleural Mesothelioma (MPM) Using Pulsed-Protracted External Beam Radiation (PERT) and Intrapleural Delivery of Stem Cells

    Science.gov (United States)

    2014-09-01

    Malignant Pleural Mesothelioma (MPM) survival remains poor despite multidisciplinary treatment involving aggressive surgery, chemotherapy and... Mesothelioma (MPM) survival remains poor despite multidisciplinary treatment involving aggressive surgery, chemotherapy and adjuvant radiotherapy (RT... Mesothelioma (MPM) Using Pulsed-Protracted External Beam Radiation (PERT) and Intrapleural Delivery of

  20. A comparison in cosmetic outcome between per-operative interstitial breast implants and delayed interstitial breast implants after external beam radiotherapy

    NARCIS (Netherlands)

    Pieters, Bradley R.; Hart, Augustinus A. M.; Russell, Nicola S.; Jansen, Edwin P. M.; Peterse, Johannes L.; Borger, Jacques; Rutgers, Emiel J. Th

    2003-01-01

    Background and purpose: Interstitial implants for brachytherapy boost in the breast conserving therapy of breast cancer can be performed in two ways; implants during the tumor excision (per-operative implants) or after the external beam therapy (delayed interstitial implants). Differences in

  1. External beam radiotherapy and intracavitary brachytherapy is an acceptable treatment for locally advanced carcinoma of the uterine cervix

    Directory of Open Access Journals (Sweden)

    Md. Zillur Rahman Bhuiyan

    2016-08-01

    Full Text Available Background: Cervical carcinoma is the second most common neoplasm in women worldwide and is the most frequent cancer among women in Bangladesh. In recent years, High Dose Rate (HDR brachytherapy in combination with External Beam Radiotherapy (EBRT has been popular in the management of cancers of uterine cervix.Objectives: To evaluate the effectiveness and acute toxicity of four fractions high dose rate intracavitary brachytherapy following pelvic external beam radiotherapy in the treatment of locally advanced cervical carcinoma. Methods: Bangabandhu Sheikh Mujib Medi­cal University & NICRH chosen as a research place for EBRT and HOR brachytherapy. A typical radiotherapy treatment involves daily inadiation for several weeks. Whole pelvis was treated with total dose of SO Gy in 5 weeks. Patients were treated once a day, 5 days a week with a daily fraction size of 2.0 Gy. EBRT: Pelvic radiotherapy dose is 50 Gy in 25 fractions (2.0 Gy per fraction over 5 weeks. HDR brachytberapy dose is 7 Gy per fraction, total 4 fractions, each in a week over 4 weeks. Results: Ninety-eight patients were entered in the study. Three patients were excluded due to active non-malignant diseases. One patient had active tuberculosis, two patients had severe skin reactions and two patients withdrew following the first HDR application. The remaining Ninety patients were analyzed. Ninety patients completed the prescribed treatment and were evaluated. Eighty had complete response with relief of symptoms, negative Pap-smear and no clinical signs of persistence disease at 3 months. Ten patients had a positive Pap-smear with clinical signs of persis­tence disease. Patients were evaluated before statting treatment with EBRT and before starting treatment with HDR ICBT. Conclusion: It can be easily concluded that 4 fractions of HDR ICBT, 7 Gy each weekly and pelvic EBRT can effectively and safely control locally advanced carcinoma of the uterine cervix. So that EBRT and HDR ICBT

  2. Muscle invasive bladder cancer treated by transurethral resection, followed by external beam radiation and interstitial iridium-192

    International Nuclear Information System (INIS)

    Wijnmaalen, Arendjan; Helle, Peter A.; Koper, Peter C.M.; Jansen, Peter P.; Hanssens, Patrick E.J.; Boeken Kruger, Cornelis G.G.; Putten, Wim L.J. van

    1996-01-01

    Purpose: In our center interstitial radiation has played an important role in the treatment of bladder cancer patients for over 40 years. Radium needles, that were initially used, were replaced by caesium needles in 1983, whereas the afterloading iridium wire technique was adopted in 1989. Patients with solitary tumors (T1, T2 and T3) with a surface diameter of < 5 cm are considered for interstitial radiation. In this study we report on the results of the afterloading iridium wire technique in patients with muscle invasive bladder cancer. Materials and Methods: From May 1989 to September 1993 interstitial radiation using iridium wires was part of the treatment in 46 patients with muscle invasive bladder cancer (37 T2, 9 T3). The mean age was 67 years. After transurethral resection of all visible tumor (if possible), in most cases 40 Gy (20 x 2.0 Gy, midplane dose) external beam radiation was delivered to the true pelvis, followed by 30 Gy interstitial radiation using iridium-192 wires covering the tumor area in the bladder. Results: After a median follow-up of 26 months, bladder relapses occurred in 7 patients. In 5 of them the tumor relapsed in the initial area, in 1 patient elsewhere in the bladder and in 1 patient tumor recurred in and outside the initial site. Recurrence was superficial (T1) in 4 patients. A relapse in the urethra was found once. Metastases developed in 13 patients, in 8 without bladder relapse. During the observation period 17 patients died, 13 due to bladder cancer. The actuarial bladder relapse-free survival at 4 years was 74% and 82% for T2 and T3 tumors, respectively. The actuarial distant metastases-free survival was 65% for both categories. No serious toxicity was recorded. Conclusion: In a selected group of patients with muscle invasive bladder cancer transurethral resection in combination with external beam and interstitial radiation provides an excellent opportunity to preserve the bladder with a high chance of success. Development of

  3. Prevalence and Predicting Factors for Commonly Neglected Sexual Side Effects to External-Beam Radiation Therapy for Prostate Cancer.

    Science.gov (United States)

    Frey, Anders; Pedersen, Christian; Lindberg, Henriette; Bisbjerg, Rasmus; Sønksen, Jens; Fode, Mikkel

    2017-04-01

    Changes in sexual function other than erectile dysfunction are sparsely investigated after radiation therapy for prostate cancer. To investigate orgasmic dysfunction, urinary incontinence during sexual activity, changes in penile morphology, and sensory disturbances in the penis in patients with prostate cancer treated with external-beam radiation therapy (EBRT). In February 2015, men treated with EBRT at our center 3 months to 5 years previously (N = 519) received a study-specific questionnaire. This was developed from purpose-built questions and validated tools including the Erection Hardness Scale. All patients had received a radiation dose of 78 Gy. Androgen deprivation therapy was administered according to disease characteristics. Outcome measurements were prevalence rates and predictors of these side effects as identified by multivariate logistic regression analyses. One hundred nine patients were eligible (sexually active and had completed androgen deprivation therapy) for inclusion. Twenty-four percent reported anorgasmia, 44% reported a decreased intensity of their orgasms, and 40% reported that the time it took to reach orgasm had increased. Eleven percent reported anejaculation. Fifteen percent reported orgasm-associated pain. Only 4% reported urinary incontinence during sexual activity. Subjective penile length loss in excess of 1 cm was reported by 42%. Twelve percent reported an altered curvature of their penis after EBRT. Six percent reported painful erections. Twenty-seven percent reported decreased sensitivity in the penis after EBRT, 2% reported a cold sensation, and 2% reported paresthesia. Increasing time since final treatment increased the risk of penile sensory disturbances (odds ratio = 1.05; P = .028). Orgasmic dysfunction, changes in penile morphology, and sensory disturbances in the penis are common side effects of ERBT. Patients should be properly informed of the occurrence of these side effects before deciding which treatment to

  4. Local tumor control and morbidity after one to three fractions of stereotactic external beam irradiation for uveal melanoma.

    Science.gov (United States)

    Zehetmayer, M; Kitz, K; Menapace, R; Ertl, A; Heinzl, H; Ruhswurm, I; Georgopoulos, M; Dieckmann, K; Pötter, R

    2000-05-01

    To evaluate prospectively local tumor control and morbidity after 1-3 fractions of stereotactic external beam irradiation (SEBI) in patients with uveal melanoma, unsuitable for ruthenium-106 brachytherapy or local resection. This phase I/II study includes 62 selected patients with uveal melanoma. The mean initial tumor height was 7.8+/-2.8 mm. With the Leskell gamma knife SEBI, 41 patients (66%) were irradiated with two equal fractions of 35, 30 or 25 Gy/fraction, 14 patients (22%) were treated with three fractions of 15 Gy each, and seven patients (11%) with small tumor volumes below 400 mm(3) were treated with one fraction of 45 Gy. The mean total dose was 54+/-8 Gy. The minimal follow-up period was 12 months, and the median follow-up was 28.3 months. Data on radiation-induced side-effects were analyzed with the Cox proportional hazards model for possible risk factors. Local tumor control was achieved in 98% and tumor height reduction in 97%. The mean relative tumor volume reductions were 44, 60 and 72% after 12, 24 and 36 months, respectively. Seven patients developed metastases (11%). Secondary enucleation was performed in eight eyes (13%). Morbidity was significant in tumors exceeding 8 mm in initial height; it was comparable and acceptable in those smaller. In the stepwise multiple Cox model, tumor localization, height and volume, planning target volume (PTV), total dose and patient age were identified as the strongest risk factors for radiation-induced lens opacities, secondary glaucoma, uveitis, eyelash loss and exudative retinal detachment. In this model, the high-dose volume irradiated with more than 10 Gy/fraction was the strongest risk factor for radiation-induced uveitis. Stereotactic external photon beam irradiation and a total dose of 45-70 Gy delivered in one to three fractions are highly effective at achieving local tumor control in uveal melanoma. Further clinical studies using smaller fraction doses, and consequent smaller high-dose volumes, are

  5. Nonlinear dynamics and chaotization of oscillations of a virtual cathode in an annular electron beam in a uniform external magnetic field

    International Nuclear Information System (INIS)

    Kurkin, S. A.; Koronovski, A. A.; Hramov, A. E.

    2009-01-01

    Results are presented from a numerical study of the effect of an external magnetic field on the conditions and mechanisms for the formation of a virtual cathode in a relativistic electron beam. Characteristic features of the nonlinear dynamics of an electron beam with a virtual cathode are considered when the external magnetic field is varied. Various mechanisms are investigated by which the virtual cathode oscillations become chaotic and their spectrum becomes a multifrequency spectrum, thereby complicating the dynamics of the vircator system. A general mechanism for chaotization of the oscillations of a virtual cathode in a vircator system is revealed: the electron structures that form in an electron beam interact by means of a common space charge field to give rise to additional internal feedback. That the oscillations of a virtual cathode change from the chaotic to the periodic regime is due to the suppression of the mechanism for forming secondary electron structures.

  6. External Beam Radiotherapy for Focal Lymphoepithelioma-Like Carcinoma in the Urinary Bladder: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Nobuhiro Kushida

    2015-01-01

    Full Text Available Lymphoepithelioma is a malignant epithelial tumor in the nasopharynx characterized by prominent lymphoid infiltration. Carcinomas that resemble lymphoepitheliomas have been called lymphoepithelioma-like carcinomas and have been reported in other organs. A tumor in the bladder is categorized by the percentage of the total area occupied by the lymphoepithelioma-like carcinoma pattern, with the prognosis dependent on the percentage. We present an 81-year-old man with stage 3 chronic obstructive pulmonary disease and a history of aortic aneurysm repair. The computed tomography scans indicated thickening and irregularity of the bladder wall, with left external iliac lymph node metastasis. His diagnosis was bladder cancer, and the clinical stage was evaluated as T3N1M0. Transurethral resection of the bladder tumor was performed, and the pathological specimen showed that the tumor was composed of undifferentiated malignant cells with sheets and nests arranged in a syncytial pattern, as well as an urothelial carcinoma lesion. A prominent lymphoid reaction accompanied the tumor. The pathological diagnosis was focal-type lymphoepithelioma-like carcinoma containing a component of urothelial carcinoma G3>G2. His general condition was such that he could not tolerate radical cystectomy or systemic chemotherapy. External beam radiotherapy (total 60 Gy was given to the bladder, including the lymph node metastatic lesion. No cancer recurrence was detected by regular follow-up computed tomography and cystoscopy. He eventually died of other causes 48 months later. Although treatment for focal lymphoepithelioma-like carcinoma generally requires multifocal therapies, in the present case, the bladder became tumor free. We also summarize previously reported lymphoepithelioma-like carcinoma cases treated with radiotherapy.

  7. Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer

    International Nuclear Information System (INIS)

    Kim, Yongbok; Parda, David S.; Trombetta, Mark G.; Colonias, Athanasios; Werts, E. Day; Miller, Linda; Miften, Moyed

    2007-01-01

    A dosimetric comparison was performed on external-beam three-dimensional conformal partial breast irradiation (PBI) and whole breast irradiation (WBI) plans for patients enrolled in the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol at our institution. Twenty-four consecutive patients were treated with either PBI (12 patients) or WBI (12 patients). In the PBI arm, the lumpectomy cavity was treated to a total dose of 38.5 Gy at 3.85 Gy per fraction twice daily using a four-field noncoplanar beam setup. A minimum 6 h interval was required between fractions. In the WBI arm, the whole breast including the entirety of the lumpectomy cavity was treated to a total dose of 50.4 Gy at 1.8 Gy per fraction daily using opposed tangential beams. The lumpectomy cavity volume, planning target volume for evaluation (PTV E VAL), and critical structure volumes were contoured for both the PBI and WBI patients. Dosimetric parameters, dose volume histograms (DVHs), and generalized equivalent uniform dose (gEUD) for target and critical structures were compared. Dosimetric results show the PBI plans, compared to the WBI plans, have smaller hot spots in the PTV E VAL (maximum dose: 104.2% versus 110.9%) and reduced dose to the ipsilateral breast (V50: 48.6% versus 92.1% and V100: 10.2% versus 50.5%), contralateral breast (V3: 0.16% versus 2.04%), ipsilateral lung (V30: 5.8% versus 12.7%), and thyroid (maximum dose: 0.5% versus 2.0%) with p values ≤0.01. However, similar dose coverage of the PTV E VAL (98% for PBI and 99% for WBI, on average) was observed and the dose difference for other critical structures was clinically insignificant in both arms. The gEUD data analysis showed the reduction of dose to the ipsilateral breast and lung, contralateral breast and thyroid. In addition, preliminary dermatologic adverse event assessment data suggested reduced skin toxicity for patients treated with the PBI technique

  8. Postoperative Chemoradiation Therapy in High-Risk Cervical Cancer: Re-evaluating the Findings of Gynecologic Oncology Group Study 109 in a Large, Population-Based Cohort

    Energy Technology Data Exchange (ETDEWEB)

    Trifiletti, Daniel M. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Swisher-McClure, Samuel [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Hegarty, Sarah E. [Division of Biostatistics, Department of Pharmacology and Experimental Therapeutics, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2015-12-01

    Purpose: To review the National Cancer Database (NCDB) to evaluate postoperative high-risk cervical cancer patients for factors associated with a benefit from chemoradiation therapy (CRT) over external beam radiation therapy alone (EBRT). Methods and Materials: The National Cancer Database was queried for women with cervical cancer treated with hysterectomy and adjuvant EBRT from 2002 to 2012. Only patients with pathologic lymph node involvement (LN+), positive surgical margins, and/or parametrial invasion were included in our analysis (on the basis of Peter's criteria). Univariable and multivariable analyses (MVA) were performed, and hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated to investigate for factors associated with of CRT utilization and overall survival (OS). Results: A total of 3053 patients met inclusion criteria, and 2479 received adjuvant CRT (81%), whereas 574 (19%) received EBRT alone. Factors associated with increased CRT utilization on MVA included age <69 years, year of diagnosis ≥2008, non-adenocarcinoma histology, and LN+. Use of CRT improved OS among the entire cohort on MVA (HR 0.76, CI 0.601-0.962; P=.022). On MVA, CRT improved OS in patients with LN+ as their sole Peter's criteria (HR 0.58, CI 0.413-0.814; P=.002). Chemoradiation therapy did not improve OS in patients with only positive margins (P=.73), only parametrial invasion (P=.95), or any combination of these 2 factors without LN+ (P=.63). Conclusions: The use of adjuvant CRT after hysterectomy improves OS in patients with high-risk cervical cancer compared with EBRT alone, but this benefit seems to be restricted to patients with LN+. The benefits of adjuvant CRT over EBRT alone in patients with parametrial invasion and/or positive margins (without nodal involvement) are unknown.

  9. [Diagnostic accuracy of cone beam computed tomography and eight-slice computed tomography for evaluation of external root reabsorption].

    Science.gov (United States)

    Xie, Xiao-yan; Zhang, Zu-yan

    2012-08-18

    To evaluate the diagnostic accuracy of cone beam computed tomography (CBCT) and high resolution multi-slice computed tomography (MSCT) with eight-detector-rows in detecting the simulated external root resorption defects. External root resorption defects of different sizes and in different locations were simulated in 40 human single rooted teeth. Cavities simulating root resorption defects of 1 mm in diameter and 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm in depth were drilled in the cervical, middle and apical thirds of lingual surfaces of the teeth. The specimens were scanned with both CBCT (Accuitomo 3DX, Morita Co., Japan) and high resolution 8-slice CT (BrightSpeed Edge, GE Co., USA). The CBCT and MSCT images were read by two experienced observers. The data were analyzed with receiver operating characteristics (ROC) analysis. ROC curves were generated and the area under ROC curve (Az) was employed to express the diagnostic accuracy. The diagnostic accuracy (Az value) in detecting the simulated defects of all the locations and sizes were 0.921 for CBCT and 0.770 for MSCT. The Az values for CBCT in detecting defects located in the cervical, middle and apical thirds were 0.885, 0.991 and 0.873, while those for MSCT were 0.752, 0.844 and 0.709, respectively. The Az values for CBCT in detecting the defects of 0.1 mm, 0.2 mm, 0.3 mm and 0.4 mm in depth were 0.794, 0.934, 0.992 and 0.992, and those for MSCT were 0.592, 0.719, 0.920 and 0.990, respectively. The diagnostic ability for external root resorption of CBCT is better than that of MSCT. Smaller defects are better delineated with CBCT than with MSCT. The defects in the middle thirds of the roots are easier to be detected than those in the cervical and apical ones using both CBCT and MSCT.

  10. Normal tissue tolerance to external beam radiation therapy: The mandible; Dose de tolerance des tissus sains: la mandibule

    Energy Technology Data Exchange (ETDEWEB)

    Berger, A.; Bensadoun, R.J. [Service d' oncologie radiotherapie, PRC, CHU de la Miletrie, 86 - Poitiers (France)

    2010-07-15

    Describing dose constraints for organs at risk in external beam radiotherapy is a key-point in order to maximize the therapeutic ratio. In head and neck irradiation, mandible is frequently exposed to ionising radiation-related complications. Those complications will be exposed after a short description of anatomical and physiopathological aspects. A literature search was performed using the Pubmed-Medline database, with following keywords (Osteoradionecrosis, Radiotherapy, Mandible, Toxicity, Organ at risk, Trismus). Incidence and dose constraints will be reported. The incidence of osteoradionecrosis decreased since the 1990, but it remains a dreaded late complication of head and neck cancer radiotherapy. It essentially occurs with cumulative doses of 66 Gy on the mandible (standard fractionation) applied to a significant volume. Respecting oral care is crucial to avoid this kind of complication. The respect of the dose-constraint described should not lead to under treat tumor bed in a curative intent. Trismus related to ionising radiation is poorly described. Literature data cannot lead to describe precise dose constraints. (authors)

  11. External beam radiotherapy synergizes 188Re-liposome against human esophageal cancer xenograft and modulates 188Re-liposome pharmacokinetics

    Science.gov (United States)

    Chang, Chih-Hsien; Liu, Shin-Yi; Chi, Chih-Wen; Yu, Hsiang-Lin; Chang, Tsui-Jung; Tsai, Tung-Hu; Lee, Te-Wei; Chen, Yu-Jen

    2015-01-01

    External beam radiotherapy (EBRT) treats gross tumors and local microscopic diseases. Radionuclide therapy by radioisotopes can eradicate tumors systemically. Rhenium 188 (188Re)-liposome, a nanoparticle undergoing clinical trials, emits gamma rays for imaging validation and beta rays for therapy, with biodistribution profiles preferential to tumors. We designed a combinatory treatment and examined its effects on human esophageal cancer xenografts, a malignancy with potential treatment resistance and poor prognosis. Human esophageal cancer cell lines BE-3 (adenocarcinoma) and CE81T/VGH (squamous cell carcinoma) were implanted and compared. The radiochemical purity of 188Re-liposome exceeded 95%. Molecular imaging by NanoSPECT/CT showed that BE-3, but not CE81T/VGH, xenografts could uptake the 188Re-liposome. The combination of EBRT and 188Re-liposome inhibited tumor regrowth greater than each treatment alone, as the tumor growth inhibition rate was 30% with EBRT, 25% with 188Re-liposome, and 53% with the combination treatment at 21 days postinjection. Combinatory treatment had no additive adverse effects and significant biological toxicities on white blood cell counts, body weight, or liver and renal functions. EBRT significantly enhanced the excretion of 188Re-liposome into feces and urine. In conclusion, the combination of EBRT with 188Re-liposome might be a potential treatment modality for esophageal cancer. PMID:26056445

  12. The importance of adequate follow-up in defining treatment success after external beam irradiation for prostate cancer

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Kestin, Larry L.; Martinez, Alvaro A.

    1999-01-01

    Purpose: We reviewed our institution's experience treating patients with localized prostate cancer with external beam radiation therapy (RT) to determine how differences in the length of follow-up affect the determination of treatment outcome using the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus Panel Definition of biochemical failure (BF). Methods and Materials: From January 1987 through December 1997, 1109 patients with localized prostate cancer were treated with definitive external beam RT at William Beaumont Hospital, Royal Oak, Michigan. All patients received external beam RT to a median total prostate dose of 66.6 Gy (range: 59.4-70.4 Gy). A total of 1096 patients (99%) had sufficient prostate-specific antigen (PSA) follow-up to determine their biochemical status. To test the impact of differences in follow-up on the calculation of BF, 389 patients with at least 5 years of PSA follow-up were selected as the reference group for the initial analysis. BF was then retrospectively determined using the Consensus Panel definition at yearly intervals, ignoring the remainder of each patient's follow-up. The median follow-up for this group of patients was 6.6 years (range: 5.0-11.6 years). In a second analysis, patient cohorts were randomly selected with varying median PSA follow-up intervals in order to more accurately represent a population whose follow-up is distributed continuously over a defined range. Seven cohorts were randomly selected with 200 patients in each cohort. Cohorts were individually identified such that half of the patients (100) had 2 years or less follow-up than the stated time point for analysis and half (100) had up to 2 years more follow-up than the time point chosen for analysis. For example, in the cohort with a median follow-up of 3 years, 100 patients with a PSA follow-up from 1 to 3 years were randomly selected, and 100 patients with a follow-up from 3 to 5 years were randomly selected, thus generating a

  13. Study of Z > 18 elements concentration in tree rings from surroundings forests of the Mexico Valley using external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calva-Vazquez, G. [Laboratorio de Contaminacion Atmosferica, FES Zaragoza, UNAM, Calzada I. Zaragoza esq., Av. Guelatao s/n, 09230 Mexico, DF (Mexico); Razo-Angel, G. [Laboratorio de Contaminacion Atmosferica, FES Zaragoza, UNAM, Calzada I. Zaragoza esq., Av. Guelatao s/n, 09230 Mexico, DF (Mexico); Rodriguez-Fernandez, L. [Instituto de Fisica, UNAM, Apartado Postal 20-364, 01000 Mexico, DF (Mexico); Ruvalcaba-Sil, J.L. [Instituto de Fisica, UNAM, Apartado Postal 20-364, 01000 Mexico, DF (Mexico)]. E-mail: sil@fisica.unam.mx

    2006-08-15

    The concentration of elements with Z > 18 is measured in tree rings from forests at the surroundings of the Mexico Valley: El Chico National Park (ECP) and Desierto de los Leones National Park (DLP). The analysis was done by simultaneous PIXE-RBS using an external proton beam on tree rings of Pine and Sacred fir (species Pinus montezumae and Abies religiosa, respectively). This study provides information about the elemental concentration in trees of those parks during the years from 1965 to 2003. Typical elements such as K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr and Pb were detected using PIXE technique while the wood matrix composition (mainly C and O) was determined by RBS. In general, elemental contents present large variations but concentrations oscillate around the mean value during this period of time. Nevertheless, the measurements showed some trends for Fe and Zn in the tree-rings elemental composition that may be correlated to recent volcanic activities in the region. The low Mn contents indicate soil acidification in DLP from 1968 and the forest decline in ECP during the last 15 years.

  14. Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy.

    Science.gov (United States)

    Hirata, Kimiko; Yoshimura, Michio; Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Inoue, Minoru; Sasaki, Makoto; Fujimoto, Takahiro; Yano, Shinsuke; Nakata, Manabu; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-07-01

    We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5mm in all directions. A systematic baseline drift of 1.5mm towards the posterior direction and a random baseline drift of 0.3mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5mm in patients with greater fat thickness due to the baseline drift. The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Use of 3D printers to create a patient-specific 3D bolus for external beam therapy.

    Science.gov (United States)

    Burleson, Sarah; Baker, Jamie; Hsia, An Ting; Xu, Zhigang

    2015-05-08

    The purpose of this paper is to demonstrate that an inexpensive 3D printer can be used to manufacture patient-specific bolus for external beam therapy, and to show we can accurately model this printed bolus in our treatment planning system for accurate treatment delivery. Percent depth-dose measurements and tissue maximum ratios were used to determine the characteristics of the printing materials, acrylonitrile butadiene styrene and polylactic acid, as bolus material with physical density of 1.04 and 1.2 g/cm3, and electron density of 3.38 × 10²³ electrons/cm3 and 3.80 × 10²³ electrons/ cm3, respectively. Dose plane comparisons using Gafchromic EBT2 film and the RANDO phantom were used to verify accurate treatment planning. We accurately modeled a printing material in Eclipse treatment planning system, assigning it a Hounsfield unit of 260. We were also able to verify accurate treatment planning using gamma analysis for dose plane comparisons. With gamma criteria of 5% dose difference and 2 mm DTA, we were able to have 86.5% points passing, and with gamma criteria of 5% dose difference and 3 mm DTA, we were able to have 95% points passing. We were able to create a patient-specific bolus using an inexpensive 3D printer and model it in our treatment planning system for accurate treatment delivery.

  16. Early effect of external beam radiation therapy on the anal sphincter: A study using anal manometry and transrectal ultrasound

    International Nuclear Information System (INIS)

    Birnbaum, E.H.; Dreznik, Z.; Myerson, R.J.; Lacey, D.L.; Fry, R.D.; Kodner, I.J.; Fleshman, J.W.

    1992-01-01

    The early of pelvic irradiation on the anal sphincter has not been previously investigated. This study prospectively evaluated the acute effect of preoperative radiation on anal function. Twenty patients with rectal carcinoma received 4,500 cGy of preoperative external beam radiation. The field of radiation included the sphincter in 10 patients and was delivered above the anorectal ring in 10 patients. Anal manometry and transrectal ultrasound were performed before and four weeks after radiotherapy. No significant difference in mean maximal squeeze or resting pressure was found after radiation therapy. An increase in mean minimal sensory threshold was significant. Histologic examination revealed minimal radiation changes at the distal margin in 8 of 10 patients who underwent low anterior resection and in 1 of 3 patients who underwent abdominoperineal resection. The authors conclude that preoperative radiation therapy has minimal immediate effect on the anal sphincter and is not a major contributing factor to postoperative incontinence in patients after sphincter-saving operations for rectal cancer

  17. Impact of Concurrent Androgen Deprivation on Fiducial Marker Migration in External-beam Radiation Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tiberi, David A.; Carrier, Jean-Francois; Beauchemin, Marie-Claude; Nguyen, Thu Van; Beliveau-Nadeau, Dominic [Departement de Radio-Oncologie, Centre hospitalier de l' Universite de Montreal-Hopital Notre-Dame, Montreal, Quebec (Canada); Taussky, Daniel, E-mail: daniel.taussky.chum@ssss.gouv.qc.ca [Departement de Radio-Oncologie, Centre hospitalier de l' Universite de Montreal-Hopital Notre-Dame, Montreal, Quebec (Canada)

    2012-09-01

    Purpose: To determine the extent of gold fiducial marker (FM) migration in patients treated for prostate cancer with concurrent androgen deprivation and external-beam radiation therapy (EBRT). Methods and Materials: Three or 4 gold FMs were implanted in 37 patients with prostate adenocarcinoma receiving androgen deprivation therapy (ADT) in conjunction with 70-78 Gy. Androgen deprivation therapy was started a median of 3.9 months before EBRT (range, 0.3-12.5 months). To establish the extent of FM migration, the distance between each FM was calculated for 5-8 treatments once per week throughout the EBRT course. For each treatment, the distance between FMs was compared with the distance from the digitally reconstructed radiographs generated from the planning CT. A total of 281 treatments were analyzed. Results: The average daily migration was 0.8 {+-} 0.3 mm, with distances ranging from 0.2 mm-2.6 mm. Two of the 281 assessed treatments (0.7%) showed migrations >2 mm. No correlation between FM migration and patient weight or time delay between ADT and start of EBRT was found. There was no correlation between the extent of FM migration and prostate volume. Conclusion: This is the largest report of implanted FM migration in patients receiving concomitant ADT. Only 0.7% of the 281 treatments studied had significant marker migrations (>2 mm) throughout the course of EBRT. Consequently, the use of implanted FMs in these patients enables accurate monitoring of prostate gland position during treatment.

  18. CT-Guided 125I Seed Interstitial Brachytherapy as a Salvage Treatment for Recurrent Spinal Metastases after External Beam Radiotherapy

    Science.gov (United States)

    Yao, Lihong; Cao, Qianqian; Yang, Jiwen; Meng, Na; Guo, Fuxin; Jiang, Yuliang; Tian, Suqing; Sun, Haitao

    2016-01-01

    The aim of this study is to evaluate the feasibility, safety, and clinical efficacy of CT-guided 125I seed interstitial brachytherapy in patients with recurrent spinal metastases after external beam radiotherapy (EBRT). Between August 2003 and September 2015, 26 spinal metastatic lesions (24 patients) were reirradiated by this salvage therapy modality. Treatment for all patients was preplanned using a three-dimensional treatment planning system 3–5 days before 125I seed interstitial brachytherapy; dosimetry verification was performed immediately after seed implantation. Median actual D 90 was 99 Gy (range, 90–176), and spinal cord median D max was 39 Gy (range, 6–110). Median local control (LC) was 12 months (95% CI: 7.0–17.0). The 6- and 12-month LC rates were 52% and 40%, respectively. Median overall survival (OS) was 11 months (95% CI: 7.7–14.3); 6-month and 1-, 2-, and 3-year OS rates were 65%, 37%, 14%, and 9%, respectively. Pain-free survival ranged from 2 to 42 months (median, 6; 95% CI: 4.6–7.4). Treatment was well-tolerated, with no radiation-induced vertebral compression fractures or myelopathy reported. Reirradiation with CT-guided 125I seed interstitial brachytherapy appears to be feasible, safe, and effective as pain relief or salvage treatment for patients with recurrent spinal metastases after EBRT. PMID:28105434

  19. CT-Guided 125I Seed Interstitial Brachytherapy as a Salvage Treatment for Recurrent Spinal Metastases after External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Lihong Yao

    2016-01-01

    Full Text Available The aim of this study is to evaluate the feasibility, safety, and clinical efficacy of CT-guided 125I seed interstitial brachytherapy in patients with recurrent spinal metastases after external beam radiotherapy (EBRT. Between August 2003 and September 2015, 26 spinal metastatic lesions (24 patients were reirradiated by this salvage therapy modality. Treatment for all patients was preplanned using a three-dimensional treatment planning system 3–5 days before 125I seed interstitial brachytherapy; dosimetry verification was performed immediately after seed implantation. Median actual D90 was 99 Gy (range, 90–176, and spinal cord median Dmax was 39 Gy (range, 6–110. Median local control (LC was 12 months (95% CI: 7.0–17.0. The 6- and 12-month LC rates were 52% and 40%, respectively. Median overall survival (OS was 11 months (95% CI: 7.7–14.3; 6-month and 1-, 2-, and 3-year OS rates were 65%, 37%, 14%, and 9%, respectively. Pain-free survival ranged from 2 to 42 months (median, 6; 95% CI: 4.6–7.4. Treatment was well-tolerated, with no radiation-induced vertebral compression fractures or myelopathy reported. Reirradiation with CT-guided 125I seed interstitial brachytherapy appears to be feasible, safe, and effective as pain relief or salvage treatment for patients with recurrent spinal metastases after EBRT.

  20. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F., E-mail: lucarelli@fi.infn.it; Calzolai, G.; Chiari, M.; Giannoni, M.; Mochi, D.; Nava, S.; Carraresi, L.

    2014-01-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN in Florence, an external beam facility is fully dedicated to measurements of elemental composition of atmospheric aerosol. The experimental set-up hitherto used for this kind of applications has been upgraded with the replacement of a traditional Si(Li) detector for the detection of medium–high Z elements with a silicon drift detector (SDD) with a big active area (80 mm{sup 2}) and 450 μm thickness, with the aim of obtaining better minimum detection limits (MDL) and reduce measuring times. The Upilex extraction window has been replaced by a more resistant one (Si{sub 3}N{sub 4}). A comparison between the old Si(Li) and the new SDD for aerosol samples collected on different substrata like Teflon, Kapton and Nuclepore evidenced the better performances of the SDD. It allows obtaining better results (higher counting statistics, lower MDLs) even in shorter measuring times, thus allowing very fast analysis of both daily and hourly samples.

  1. The upgraded external-beam PIXE/PIGE set-up at LABEC for very fast measurements on aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F.; Calzolai, G.; Chiari, M.; Mochi, D.; Nava, S. [Department of Physics, University of Florence and INFN, Florence (Italy)

    2013-07-01

    Full text: Particle Induced X-ray Emission (PIXE)technique has been widely used since its birth for the study of the aerosol composition, and for a long time it has been the dominating technique for its elemental analysis. However now it has to compete with other techniques, like Induced Coupled Plasma and detection by Atomic Emission Spectroscopy (ICP-AES) or Mass Spectrometry (ICP-MS) or Synchrotron Radiation XRF (SR-XRF). To remain competitive, a proper experimental set-up is important to fully exploit PIXE capabilities. At LABEC, an external beam line is fully dedicated to PIXE-PIGE measurements of atmospheric aerosols [1]. Recently SDD (Silicon Drift Detectors) have been introduced for X-ray detection thanks to their better resolution with respect to Si(Li) detectors and the possibility of managing high counting rates (up to 50 kHz at 0.5 μsec shaping time). This implies, in turn, the possibility of using very high beam currents thus drastically reducing the measurement time. However their use for a complete characterization of X-rays was limited by the small thickness and surface areas available. Now SDD with a thickness of 500 μm and 80 mm{sup 2} area have been introduced in the market. We have therefore replaced the Si(Li) detector used so far for the detection of medium-high Z elements with such a SDD. A comparison of the two detectors has been carried out; PIXE minimum detection limits (MDLs) at different proton beam energies have been studied to find out the best energy for PIXE measurements on aerosol samples collected on different substrata, namely Teflon, Kapton, Nuclepore and Kimfol, used for daily or hourly sampling or for cascade impactors. In particular in the case of Teflon filters, the production of γ-rays by F in the Teflon filter limits the current which may be used and the Compton γ-ray background worsens the MDLs. Due to the lower thickness of the SDD detector with respect to a typical Si(Li) detector, these problems are reduced

  2. Acute toxicity of chemoradiation for rectal cancer

    International Nuclear Information System (INIS)

    Roedel, C.; Fietkau, R.; Keilholz, L.; Grabenbauer, G.G.; Kessler, H.; Martus, P.; Sauer, R.

    1997-01-01

    Between 1987 and 1995, 120 patients with rectal cancer (73 patients with primary tumor, 47 with recurrent disease) received chemoradiation for rectal cancer. Fifty-six patients received preoperative chemoradiation, 64 patients were treated postoperatively. Radiation was given by 4-field box technique with 6 to 10 MV-photons. Daily fraction size was 1.8 Gy, total dose 50.4 Gy (range: 41,4 to 56 Gy) ± 5.4 Gy (range: 3.6 to 19.8 Gy) local boost in selected cases, specified to the ICRU reference point. During the first and fifth week of radiation 5-FU at a dose of 1000 m 2 /d for 120 hours was administered by continuous infusion. Toxicity was recorded following (modified) WHO-criteria. Results: Acute grade 3 toxicity occurred mainly as diarrhea (33%), perineal skin reaction (37%), and leukopenia (10%). Extension of the treatment volume including paraaortic lymph nodes (L3) led to a significant increase of grade 3-diarrhea (68% vs. 25%, p = 0.0003) and grade 3-leukopenia (18% vs. 8%, p 0.03). After abdominoperineal resection less patients suffered from grade 3-diarrhea (8% vs. 47% after sphincter preserving procedures, p = 0.0006), whereas severe perineal erythema occurred more frequently (56% vs. 29%, p 0.02). Women had significantly more toxic side effects (grade 3-diarrhea: 39% vs. 16% in men, p = 0,04; grade 2 to 3-nausea/emesis: 21% vs 8% in men, p 0.018; grade 2 to 3-leukopenia 53% vs. 31% in men, p = 0.02). After preoperative chemoradiation a significant reduction of grade 3-diarrhea (11% vs 29%, p 0.03) and grade 3-erythema (16% vs. 41%, p = 0.04) was noted. (orig./AJ) [de

  3. Chemoradiation for adenocarcinoma of the anus

    International Nuclear Information System (INIS)

    Papagikos, Michael; Crane, Christopher H.; Skibber, John; Janjan, Nora A.; Feig, Barry; Rodriguez-Bigas, Miguel A.; Hung, Arthur; Wolff, Robert A.; Delclos, Marc; Lin, Edward; Cleary, Karen

    2003-01-01

    Purpose: To assess the efficacy and limitations of definitive chemoradiation for adenocarcinoma of the anal canal and to propose a treatment strategy that addresses the limitations of treatment. Methods and Materials: Between 1976 and 1998, 16 patients with localized adenocarcinoma of the anal canal were treated with radiotherapy with or without chemotherapy with curative intent. Available histologic slides were reviewed for evidence of primary adenocarcinoma of anal duct origin. The treatment results for these patients were compared with those of a group of patients with epidermoid histologic features who were all treated with definitive chemoradiation (55 Gy with concurrent 5-fluorouracil and cisplatin, n=92) between 1989 and 1998. The hospital records were reviewed for all patients. Patients with epidermoid carcinoma presented with more advanced primary tumors (42% vs. 19% Stage T3 or greater). All adenocarcinoma patients were treated with radiotherapy (median dose 55 Gy): 11 received concurrent 5-fluorouracil-based chemotherapy and 5 received radiotherapy alone. The initial surgical procedures included abdominoperineal resection, excisional biopsies (n=5), and local excision (n=1). Abdominoperineal resection was performed as salvage therapy after local recurrence in 5 patients. The Kaplan-Meier method was used to calculate 5-year actuarial pelvic control, distant disease control, disease-free survival, and overall survival. The median follow-up was 45 months (range 5-196) for patients with adenocarcinoma and 44 months (range 9-115) for patients with epidermoid histologic features. Results: Both local and distant recurrence rates were significantly greater in the adenocarcinoma patients. Of 16 patients with adenocarcinoma, 7 (5-year actuarial rate 54%) had recurrence at the primary site compared with 16 (5-year actuarial rate 18%) of 92 patients with epidermoid histologic features (p=0.004). Distant disease developed in more patients with adenocarcinoma (5-year

  4. External Beam Therapy (EBT)

    Science.gov (United States)

    ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ... Cancer Treatment Head and Neck Cancer Treatment Intensity-Modulated Radiation Therapy (IMRT) Brain ...

  5. SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K [Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD (United States); Ji, T [Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD (United States); Department of Radiation Oncology, The First Hospital, China Medical University, Shenyang, Liaoning (China); Iordachita, I [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD (United States); Velarde, E; Hyatt, J; Wong, J

    2016-06-15

    Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patient couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

  6. Conformal external beam radiation or selective internal radiation therapy-a comparison of treatment outcomes for hepatocellular carcinoma.

    Science.gov (United States)

    Oladeru, Oluwadamilola T; Miccio, Joseph A; Yang, Jie; Xue, Yaqi; Ryu, Samuel; Stessin, Alexander M

    2016-06-01

    Non-operative treatment for hepatocellular carcinoma (HCC) has expanded significantly with the use of selective internal radiotherapy (SIRT) mostly with yttrium 90 ((90)Y) tagged microspheres and highly conformal external beam radiation therapy such as stereotactic body radiotherapy (SBRT) to treat unresectable liver tumors for local tumor control. SBRT is a noninvasive procedure using external radiation source under image guidance, while SIRT delivers radioactive particles by transarterial radioembolization (TARE). However, the survival benefits of SBRT versus SIRT have never been compared. The aim of the present study is to compare the outcomes of overall and disease specific survival (DSS) using SIRT versus SBRT to treat HCC. The Surveillance, Epidemiology, and End Results (SEER) registry database [2004-2011] was queried for cases of unresectable HCC. Patients with missing data and those who received surgery were excluded from the study. A total of 189 patients with unresectable HCC were identified and used for statistical analysis, with 112 receiving SBRT and 77 receiving SIRT. Overall and disease-specific survival was compared using multivariable cox proportional hazard models. After adjusting for confounding factors (age at diagnosis, gender, race, grade, stage, AFP level and type of surgery), there were no significant difference in overall survival (OS) [hazard ratio (HR), 0.72; 95% confidence interval (CI), 0.49-1.07; P=0.1077] and DSS (HR, 0.70; 95% CI, 0.46-1.05; P=0.0880) for SIRT compared to SBRT. However, patients with elevated AFP level were associated with higher death risk (P=0.0459) and disease specific death risk (P=0.0233) than those with AFP within normal limits in both treatment groups. The retrospective analysis serves as the first comparison of SIRT to SBRT in treatment of unresectable HCC. Our findings suggest both treatment approaches result in similar outcomes in overall and disease-specific survival benefit. Future prospective randomized

  7. Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sole, Claudio V., E-mail: cvsole@uc.cl [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); Calvo, Felipe A. [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Madrid (Spain); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain); Alvarez, Ana; Gonzalez, Carmen [Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Gonzalez, Jose [Service of Pediatric Orthopedics and Traumatology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); San Julian, Mikel [Service of Orthopedics and Traumatology, Clínica Universidad de Navarra, Pamplona (Spain); Martinez-Monge, Rafael [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain)

    2014-09-01

    Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results.

  8. Improvement of the beam quality of a broad-area diode laser using double feedback from two external mirrors

    DEFF Research Database (Denmark)

    Chi, M.; Bøgh, A.-S.; Thestrup, B.

    2004-01-01

    In this letter, a symmetric double-feedback configuration, to improve the beam quality of broad-area diode lasers is demonstrated. With this configuration, a symmetric double-lobed far field can be obtained, and this configuration leads to good beam quality. The beam quality factor M-2 of a diode...

  9. A survey of techniques to reduce and manage external beam radiation-induced xerostomia in British oncology and radiotherapy departments

    Energy Technology Data Exchange (ETDEWEB)

    Macknelly, Andrew [Norfolk and Norwich University Hospital (United Kingdom); Day, Jane [Faculty of Health, Wellbeing and Science, University Campus Suffolk, Waterfront Building, Neptune Quay, Ipswich (United Kingdom)], E-mail: j.day@ucs.ac.uk

    2009-11-15

    Xerostomia is the most common side effect of external beam radiotherapy to the head and neck [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et-al. Can dose reduction to one parotid gland prevent xerostomia? - A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy. Clinical Oncology 2006;18(6):497-504.]. A survey was carried out in British oncology departments to determine what treatment regimes, to minimise xerostomia, are used for patients with head-and-neck cancers treated with external beam radiotherapy. A semi-structured questionnaire consisting of both quantitative and qualitative questions was designed that asked departments which of the identified methods they used, why a method might not be currently employed, and whether its use had ever been considered. The study found that there are wide disparities between the techniques employed by oncology departments to avoid and reduce xerostomia in patients with cancers of the head and neck. The National Institute of Clinical Health and Excellence, [National Institute for Clinical Health and Excellence (NICE). Improving outcomes in head and neck cancers: the manual. London: Office of Public Sector Information; 2004.] for example, recommends that patients are given dental care and dietary advice but some departments did not appear to be doing this. Less than half of departments stated that they offer complementary therapies and less than 40% prescribed pilocarpine, a saliva-stimulant. Only two respondents stated that they use amifostine, a radioprotector, during radiotherapy treatment to the head and neck. The results also suggested a move toward using Intensity Modulated Radiotherapy (IMRT) for treating head-and-neck cancers which offers better normal tissue sparing than three-dimensional conformal radiotherapy. [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et al. Can dose reduction to one parotid gland prevent xerostomia

  10. A survey of techniques to reduce and manage external beam radiation-induced xerostomia in British oncology and radiotherapy departments

    International Nuclear Information System (INIS)

    Macknelly, Andrew; Day, Jane

    2009-01-01

    Xerostomia is the most common side effect of external beam radiotherapy to the head and neck [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et-al. Can dose reduction to one parotid gland prevent xerostomia? - A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy. Clinical Oncology 2006;18(6):497-504.]. A survey was carried out in British oncology departments to determine what treatment regimes, to minimise xerostomia, are used for patients with head-and-neck cancers treated with external beam radiotherapy. A semi-structured questionnaire consisting of both quantitative and qualitative questions was designed that asked departments which of the identified methods they used, why a method might not be currently employed, and whether its use had ever been considered. The study found that there are wide disparities between the techniques employed by oncology departments to avoid and reduce xerostomia in patients with cancers of the head and neck. The National Institute of Clinical Health and Excellence, [National Institute for Clinical Health and Excellence (NICE). Improving outcomes in head and neck cancers: the manual. London: Office of Public Sector Information; 2004.] for example, recommends that patients are given dental care and dietary advice but some departments did not appear to be doing this. Less than half of departments stated that they offer complementary therapies and less than 40% prescribed pilocarpine, a saliva-stimulant. Only two respondents stated that they use amifostine, a radioprotector, during radiotherapy treatment to the head and neck. The results also suggested a move toward using Intensity Modulated Radiotherapy (IMRT) for treating head-and-neck cancers which offers better normal tissue sparing than three-dimensional conformal radiotherapy. [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et al. Can dose reduction to one parotid gland prevent xerostomia

  11. Breast conserving surgery in combination with intraoperative radiotherapy after previous external beam therapy: an option to avoid mastectomy.

    Science.gov (United States)

    Thangarajah, F; Heilmann, J; Malter, W; Kunze, S; Marnitz, S; Mallmann, P; Wenz, F; Sperk, E

    2018-04-01

    Mastectomy is the standard procedure in patients with in-breast tumor recurrence (IBTR) or breast cancer after irradiation of the chest due to Hodgkin's disease. In certain cases a second breast conserving surgery (BCS) in combination with intraoperative radiotherapy (IORT) is possible. To date, data concerning BCS in combination with IORT in pre-irradiated patients are limited. This is the first pooled analysis of this special indication with a mature follow-up of 5 years. Patients with IBTR after external beam radiotherapy (EBRT; treated in two centers) for breast cancer were included. Patients with previous EBRT including the breast tissue due to other diseases were also included. IORT was performed with the Intrabeam™-device using low kV X-rays. Clinical data including outcome for all patients and toxicity for a representative cohort (LENT-SOMA scales) were obtained. Statistical analyses were done including Kaplan-Meier estimates for local recurrence, distant metastasis and overall survival. A total of 41 patients were identified (39 patients with IBTR, 2 with Hodgkin`s disease in previous medical history). Median follow-up was 58 months (range 4-170). No grade 3/4 acute toxicity occurred within 9 weeks. Local recurrence-free survival rate was 89.9% and overall survival was 82.7% at 5 years. Seven patients developed metastasis within the whole follow-up. BCS in combination with IORT in IBTR in pre-irradiated patients is a feasible method to avoid mastectomy with a low risk of side effects and an excellent local control and good overall survival.

  12. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  13. Survey of Stereotactic Body Radiation Therapy in Japan by the Japan 3-D Conformal External Beam Radiotherapy Group

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Hiraoka, Masahiro; Mizowaki, Takashi; Narita, Yuichiro; Matsuo, Yukinori; Norihisa, Yoshiki; Onishi, Hiroshi; Shirato, Hiroki

    2009-01-01

    Purpose: To recognize the current status of stereotactic body radiotherapy (SBRT) in Japan, using a nationwide survey conducted by the Japan 3-D Conformal External Beam Radiotherapy Group. Methods and Materials: The questionnaire was sent by mail to 117 institutions. Ninety-four institutions (80%) responded by the end of November 2005. Fifty-three institutions indicated that they have already started SBRT, and 38 institutions had been reimbursed by insurance. Results: A total of 1111 patients with histologically confirmed lung cancer were treated. Among these patients, 637 had T1N0M0 and 272 had T2N0M0 lung cancer. Metastatic lung cancer was found in 702 and histologically unconfirmed lung tumor in 291 patients. Primary liver cancer was found in 207 and metastatic liver cancer in 76 patients. The most frequent schedule used for primary lung cancer was 48Gy in 4 fractions at 22 institutions (52%), followed by 50Gy in 5 fractions at 11 institutions (26%) and 60Gy in 8 fractions at 4 institutions (10%). The tendency was the same for metastatic lung cancer. The average number of personnel involved in SBRT was 1.8 radiation oncologists, including 1.1 certified radiation oncologists, 2.8 technologists, 0.7 nurses, and 0.6 certified quality assurance personnel and 0.3 physicists. The most frequent amount of time for treatment planning was 61-120min, for quality assurance was 50-60min, and for treatment was 30min. There were 14 (0.6% of all cases) reported Grade 5 complications: 11 cases of radiation pneumonitis, 2 cases of hemoptysis, and 1 case of radiation esophagitis. Conclusion: The current status of SBRT in Japan was surveyed.

  14. [Last resort surgical management of postradiation urinary cystitis after external beam radiation for prostate cancer: a monocentric analysis].

    Science.gov (United States)

    Seisen, T; Rouprêt, M; Phé, V; Bosset, P-O; Parra, J; Drouin, S J; Simon, J-M; Chartier-Kastler, E

    2013-01-01

    To assess functional outcomes obtained after surgical management of post-radiation urinary incontinence after prostate cancer. A retrospective review of the data from patients treated in our centre between September 2004 and February 2012 by surgery for vesicosphincteric injuries after prostatic external beam radiation therapy was performed. A total of seven men with a median age of 70 years ± 4.1 were included. Mean follow-up was 32.3 months ± 29 (3-86). All patients underwent a partial cystectomy and augmentation enterocystoplasty. The vesicocutaneous fistula rate was 33% occurring within a mean time of 18.5 days ± 2.1 (17-20). The mean length of urinary catheter and hospital stay were respectively 16 days ± 8.4 (12-35) and 18 days ± 7.8 (13-37). Five patients underwent asynchronous insertion of artificial urinary sphincter. The success rate of partial cystectomy and augmentation enterocystoplasty with asynchronous implantation of artificial urinary sphincter to treat post-radiation urinary incontinence was 71.5%. The median time between partial cystectomy and augmentation enterocystoplasty and artificial urinary sphincter implantation was 27.6months ± 26.4 (7-72). Surgical management of post-radiation urinary cystitis offers good functional outcomes albeit its morbidity is not negligible. It should be proposed only in expert surgical centres. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  15. Technique of Injection of Hyaluronic Acid as a Prostatic Spacer and Fiducials Before Hypofractionated External Beam Radiotherapy for Prostate Cancer.

    Science.gov (United States)

    Boissier, Romain; Udrescu, Corina; Rebillard, Xavier; Terrier, Jean-Etienne; Faix, Antoine; Chapet, Olivier; Azria, David; Devonec, Marian; Paparel, Philippe; Ruffion, Alain

    2017-01-01

    To describe a technique combining the implantation of fiducials and a prostatic spacer (hyaluronic acid [HA]) to decrease the rectal toxicity after an image-guided external beam radiotherapy (EBRT) with hypofractionation for prostate cancer and to assess the tolerance and the learning curve of the procedure. Thirty patients with prostate cancer at low or intermediate risk were included in a phase II trial: image-guided EBRT of 62 Gy in 20 fractions of 3.1 Gy with intensity-modulated radiotherapy. A transrectal implantation of 3 fiducials and transperineal injection of 10 cc of HA (NASHA gel spacer, Q-Med AB, Uppsala, Sweden) between the rectum and the prostate was performed by 1 operator. The thickness of HA was measured at 10 points on magnetic resonance imaging to establish a quality score of the injection (maximum score = 10) and determine the learning curve of the procedure. The quality score increased from patients 1-10, 11-20, to 21-30 with respective median scores: 7 [2-10], 5 [4-7], and 8 [3-10]. The average thicknesses of HA between the base, middle part, and apex of the prostate and the rectum were the following: 15.1 mm [6.4-29], 9.8 mm [5-21.2], and 9.9 mm [3.2-21.5]. The injection of the HA induced a median pain score of 4 [1-8] and no residual pain at mid-long term. Creating an interface between the rectum and the prostate and the implantation of fiducials were feasible under local anesthesia with a short learning curve and could become a standard procedure before a hypofractionated EBRT for prostate cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Clinical significance of increased gelatinolytic activity in the rectal mucosa during external beam radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Hovdenak, Nils; Wang Junru; Sung, C.-C.; Kelly, Thomas; Fajardo, Luis F.; Hauer-Jensen, Martin

    2002-01-01

    Purpose: Rectal toxicity (proctitis) is a dose-limiting factor in pelvic radiation therapy. Mucosal atrophy, i.e., net extracellular matrix degradation, is a prominent feature of radiation proctitis, but the underlying mechanisms are not known. We prospectively examined changes in matrix metalloproteinase (MMP)-2 and MMP-9 (gelatinase A and B) in the rectal mucosa during radiation therapy of prostate cancer, as well as the relationships of these changes with symptomatic, structural, and cellular evidence of radiation proctitis. Methods and Materials: Seventeen patients scheduled for external beam radiation therapy for prostate cancer were prospectively enrolled. Symptoms of gastrointestinal toxicity were recorded, and endoscopy with biopsy of the rectal mucosa was performed before radiation therapy, as well as 2 and 6 weeks into the treatment course. Radiation proctitis was assessed by endoscopic scoring, quantitative histology, and quantitative immunohistochemistry. MMP-2 and MMP-9 were localized immunohistochemically, and activities were determined by gelatin zymography. Results: Symptoms, endoscopic scores, histologic injury, and mucosal macrophages and neutrophils increased from baseline to 2 weeks. Symptoms increased further from 2 weeks to 6 weeks, whereas endoscopic and cellular evidence of proctitis did not. Compared to pretreatment values, there was increased total gelatinolytic activity of MMP-2 and MMP-9 at 2 weeks (p=0.02 and p=0.004, respectively) and 6 weeks (p=0.006 and p=0.001, respectively). Active MMP-2 was increased at both time points (p=0.0001 and p=0.002). Increased MMP-9 and MMP-2 at 6 weeks was associated with radiation-induced diarrhea (p=0.007 and p=0.02, respectively) and with mucosal neutrophil infiltration (rho=0.62). Conclusions: Pelvic radiation therapy causes increased MMP-2 and MMP-9 activity in the rectal mucosa. These changes correlate with radiation-induced diarrhea and granulocyte infiltration and may contribute to abnormal

  17. 18F-FDG Pet-Guided External Beam Radiotherapy in Iodine-Refractory Differentiated Thyroid Cancer: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Eleonora Farina

    2017-01-01

    Full Text Available Introduction. To evaluate the clinical response rate after a postoperative 18F-FDG PET/CT guided external beam radiotherapy (EBRT in Iodine-refractory differentiated thyroid cancer. Material and Methods. Patients with thyroid cancer locally recurrent after total thyroidectomy plus metabolic radiotherapy and treated with radical EBRT were included. Inclusion criteria were detectable thyroglobulin (Tg, negative postmetabolic radiotherapy whole body scintigraphy, and no surgical indications. The pretreatment 18F-FDG PET/CT resulted positive in all cases (loggia, lymph nodes, and lung. EBRT was delivered with IMRT-SIB technique. A 18F-FDG PET/CT revaluation and Tg dosage were performed 3 months after the treatment. Results. Sixteen consecutive patients were included in this analysis (median follow-up: 6–44 months. Post-EBRT 18F-FDG PET/CT showed CR in 43.7%, PR in 31.2%, SD in 25.0% patients, and PD due to lung metastases in 12.5%. Overall response rate was 75.0% (CI 95%: 41.4–93.3%. Tg levels decreased in 75.0% with a median Δ of 68.0%. Two-year PFS and OS rates were 80.0% and 93.0%, respectively. Acute G3 toxicity occurred in 18.7% and late G2 toxicity in 12.5%. Conclusions.  18F-FDG PET/CT was useful in target definition for radiotherapy planning, identifying positive areas not detected with 131I scintigraphy. IMRT based EBRT was feasible and our results encourage future prospective studies. This clinical trial is registered with ID: NCT03191643.

  18. SU-G-TeP3-06: Nanoparticle-Aided External Beam Radiotherapy Leveraging the Cerenkov Effect

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Z; Ngwa, W [University of Massachusetts Lowell, Lowell, MA (United States); Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School (United States); Liu, B; Sajo, E [University of Massachusetts Lowell, Lowell, MA (United States); Yasmin-Karim, S [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School (United States)

    2016-06-15

    Purpose: This study investigates the feasibility of exploiting the Cerenkov radiation (CR) present during external beam radiotherapy (EBRT) for significant therapeutic gain, using titanium dioxide nanoparticles (titania) delivered via a new design of radiotherapy biomaterials. Methods: Recently published work has shown that CR generated by radionuclides during PET imaging could substantially enhance damage to cancer cells in the presence of 0.625 µg/g titania. We hypothesize that equal or greater damage can be achieved during EBRT. To test this hypothesis, Monte Carlo simulation was done using GEANT4 in order to get the total CR yield inside a tumor volume during EBRT compared to that of the radionuclides. We considered a novel approach where a sufficiently potent concentration of the titania was delivered directly into the tumor using radiotherapy biomaterials (e.g. fiducials) loaded with the titania. The intra-tumor distribution/diffusion of titania released from the fiducials was calculated. An in-vitro MTS assay experiment was also carried out to establish the relative non-toxicity of titania for concentrations of up to 1 µg/g. Results: For a radiotherapy biomaterial loaded with 15 µg/g of 2-nm titania, at least 0.625 µg/g could be delivered through out a tumor sub-volume of 2-cm diameter after 14 days. This concentration level could inflict substantial damage to tumor cells during EBRT. The Monte Carlo results showed the CR yield in tumor by 6 MV radiation was higher than the radionuclides and hence potentially greater damage may be obtained during EBRT. No significant cell viability change was observed for 1 µg/g titania. Conclusion: Altogether, these preliminary findings demonstrate a potential new approach that can be used to take advantage of the CR present during megavoltage EBRT to boost damage to tumor cells. The results provide significant impetus for further experimental studies towards development of nanoparticle-aided EBRT powered by the

  19. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  20. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  1. Migration of intraprostatic fiducial markers and its influence on the matching quality in external beam radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Delouya, Guila; Carrier, Jean-Francois; Beliveau-Nadeau, Dominic; Donath, David; Taussky, Daniel

    2010-01-01

    Purpose: To assess the influence of fiducial marker (FM) migration on the matching quality in external beam radiation therapy (EBRT) for prostate cancer. Materials and methods: The position of FMs were identified using on-board kV imaging (OBI) and their 3-D position established using an in-house reconstruction algorithm for 31 patients with prostate adenocarcinoma. To carry out the match, the positions were overlaid on the digitally reconstructed radiographs (DRR) generated from the planning CT. The distance between each FM was calculated for seven treatments throughout the EBRT course. Four radiotherapy technologists were asked to independently perform and rate the match from OBI to DRR which was then correlated to the extent of FM migration. Results: All the matches were rated by at least three radiotherapy technologists as 'very easy' ('easy' subgroup) for 24 patients (77%), while the other seven patients had their match rated less than 'very easy' and considered the 'not easy' subgroup. The average daily FM migration was 0.93 ± 0.34 mm for the 'easy' subgroup vs. 1.82 ± 0.75 mm for the latter. An average migration >2 mm was seen in five/seven patients in the 'not easy' subgroup as compared to none in the 'easy' subgroup. There was a trend towards less FM migration and better matching if the planning CT was done later than the day of the FM implant (p = 0.093). Conclusions: FM migration >2 mm predicts for a more difficult matching process; PTV margins might have to be adjusted or the planning CT repeated.

  2. Californium-252 neutron brachytherapy combined with external beam radiotherapy for esophageal cancer: long-term treatment results.

    Science.gov (United States)

    Liu, Huiming; Wang, Qifeng; Wan, Xin; Jia, Xitang; Liu, Bo; Wang, C-K Chris

    2014-01-01

    The aim of this study was to retrospectively observe and analyze the long-term treatment outcomes for a total of 952 esophageal cancer patients who were treated with (252)Cf neutron brachytherapy (NBT) in combination with external beam radiotherapy (EBRT). From November 2001 to March 2012, 952 patients with esophageal cancer underwent NBT in combination with EBRT. The patient numbers distributed over various cancer Stages I, IIA, IIB, III, and IVA were 9, 290, 51, 579, and 23, respectively. The total radiation dose to the reference point via NBT was 8-25 Gy-eq in three to five fractions with one fraction/week. The total dose via EBRT was 40-60 Gy delivered over a period of 5-6 weeks with normal fractionation. The overall median survival time was 20.3 months. The 1-, 3-, and 5-year survival rates were 67.1%, 36.3%, and 26.6%, respectively. These results compare favorably with the results obtained from conventional high-dose rate in combination with EBRT. Although a majority of the patients (860 or 90.3%) developed Grades 1 and 2 esophagitis during treatment, the symptoms were effectively relieved after the application of antacid and surface anesthesia. The clinical data show that NBT in combination with EBRT produced favorable local control and long-term survival rates for patients with esophageal cancer and that the side effects are tolerable. As such, we conclude that this dual-modality method is an effective and safe way for treating esophageal cancer. Published by Elsevier Inc.

  3. [Follow-up study of clinical effects of californium-252 neutron intracavitary radiotherapy and external beam radiotherapy in endometrial cancer].

    Science.gov (United States)

    Lei, Xin; Shan, Jin-lu; Tang, Cheng; Zhao, Ke-wei

    2007-11-01

    To observe the three year local control rate, overall survival rate, complications and prognostic factors of endometrial cancer treated with (252)Cf neutron intracavitary brachytherapy (ICBT) and external beam radiotherapy (EBRT). Forty endometrial cancer patients staged Ib - IVa by the standard of Federation of International Gynecologic Organization (FIGO), who had not received any treatment were enrolled in this study. Treatment schedules were: (252)Cf ICBT, 10 - 13 Gy(i)/fraction per week, the total dose to point A and point F 35 - 45 Gy(i) and 38 - 50 Gy(i) respectively in 4 fractions. The EBRT was given to the whole pelvic field, with 6 MV or 8 MV X-ray, 2 Gy per fraction, 4 times per week. The total dose was 45 to 50 Gy (the field was blocked 4 cm after 20 - 30 Gy), the total treatment time was 5 - 6 weeks. The follow-up time was 36 - 96 months, with an average of 42 months. The three year local control and overall survival rate was 88% (35/40) and 75% (30/40) respectively for all patients. Of those patients of stage Ib, they were 93% (14/15) and 87% (13/15), respectively, higher than stage II [80% (12/15), 87% (13/15); P > 0.05], significantly higher than stage III, IV [60% (6/10), 50% (5/10); P 252)Cf ICBT and EBRT may be safe and effective for advanced endometrial cancer. The most important prognostic factors were stage, pathological type and differentiation of endometrial cancer.

  4. Radiolabeled anti-EGFR-antibody improves local tumor control after external beam radiotherapy and offers theragnostic potential

    International Nuclear Information System (INIS)

    Koi, Lydia; Bergmann, Ralf; Brüchner, Kerstin; Pietzsch, Jens; Pietzsch, Hans-Jürgen; Krause, Mechthild

    2014-01-01

    Purpose: The effect of radioimmunotherapy (RIT) using the therapeutic radionuclide Y-90 bound to the anti-EGFR antibody cetuximab combined with external beam irradiation (EBRT) (EBRIT) on permanent local tumor control in vivo was examined. Methods: Growth delay was evaluated in three human squamous cell carcinoma models after RIT with [ 90 Y]Y-(CHX-A′′-DTPA) 4 -cetuximab (Y-90-cetuximab). The EBRT dose required to cure 50% of the tumors (TCD 50 ) for EBRT alone or EBRIT was evaluated in one RIT-responder (FaDu) and one RIT-non-responder (UT-SCC-5). EGFR expression and microenvironmental parameters were evaluated in untreated tumors, bioavailability was visualized by PET using ([ 86 Y]Y-(CHX-A′′-DTPA) 4 -cetuximab (Y-86-cetuximab) and biodistribution using Y-90-cetuximab. Results: In UT-SCC-8 and FaDu but not in UT-SCC-5 radiolabeled cetuximab led to significant tumor growth delay. TCD 50 after EBRT was significantly decreased by EGFR-targeted RIT in FaDu but not in UT-SCC-5. In contrast to EGFR expression, parameters of the tumor micromilieu and in particular the Y-90-cetuximab biodistribution or Y-86-cetuximab visualization in PET correlated with the responsiveness to RIT or EBRIT. Conclusion: EGFR-targeted EBRIT can improve permanent local tumor control compared to EBRT alone. PET imaging of bioavailability of labeled cetuximab appears to be a suitable predictor for response to EBRIT. This theragnostic approach should be further explored for clinical translation

  5. T4 rectal cancer treated with preoperative chemoradiation to the posterior pelvis followed by multivisceral resection: patterns of failure and limitations of treatment

    International Nuclear Information System (INIS)

    Sanfilippo, Nicholas J.; Crane, Christopher H.; Skibber, John; Feig, Barry; Abbruzzese, James L.; Curley, Steve; Vauthey, Jean-Nicolas; Ellis, Lee M.; Hoff, Paulo; Wolff, Robert A.; Brown, Thomas D.; Cleary, Karen; Wong, Adrian; Phan, Thinh; Janjan, Nora A.

    2001-01-01

    Purpose: To analyze the overall pattern of treatment failure and sites of pelvic disease recurrence relative to the radiation fields used in treating patients with clinically staged T4 rectal cancer with preoperative chemoradiation followed by multivisceral resection. Methods and Materials: Between 1990 and 1998, 45 patients with T4 rectal cancer were treated with preoperative chemoradiation. Clinical staging was according to the system of the American Joint Cancer Committee and was based on endoscopic ultrasonography, chemotherapy (CT), and physical examination. A diagnosis of T4 disease required evidence of invasion of a contiguous structure on CT (n 31) or endorectal ultrasonography (n=6), vaginal mucosal involvement on pelvic examination (n=6), or a combination of these findings (n=2). Chemoradiation was delivered with 18 MV photons using a 3-field belly-board technique. The median total dose was 45 Gy in all patients (range 45-63). Nine patients received a boost with external beam radiotherapy (EBRT) (n=5, 1.8-18 Gy), intraoperative RT (n=3, 10-20 Gy), or interstitial brachytherapy (n=1, 20 Gy). All patients received concurrent chemotherapy consisting of protracted venous infusion 5-fluorouracil (300 mg/m 2 , 5 d/wk). Resection was not performed in 13 (29%) of the 45 patients because of metastases detected before resection or patient refusal. Multivisceral resection and pelvic exenteration was required in 21 (66%) and 11 (34%) of 32 patients, respectively. We compared the location of pelvic disease recurrence with the RT simulation films. The Kaplan-Meier method was used to calculate the 4-year actuarial pelvic and distant recurrent rates and the overall survival rate. Results: The median length of follow-up was 31.0 months for all patients and 40.0 months for patients alive at last follow-up. When only the resected cases were considered, the local recurrence rate was 20%. Distant metastases occurred in 44% of cases; the overall survival rate was 69%. When all

  6. Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

    International Nuclear Information System (INIS)

    Donovan, E. M.; James, H.; Bonora, M.; Yarnold, J. R.; Evans, P. M.

    2012-01-01

    Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that

  7. Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Donovan, E. M.; James, H.; Bonora, M.; Yarnold, J. R.; Evans, P. M. [Joint Department of Physics, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Sutton SM2 5PT (United Kingdom); Physics Department, Ipswich Hospital NHS Foundation Trust, Ipswich IP4 5PD (United Kingdom); Department of Academic Radiotherapy, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton SM2 5PT, United Kingdom and School of Radiotherapy, University of Milan, Milan 20122 (Italy); Department of Academic Radiotherapy, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton SM2 5PT (United Kingdom); Centre for Vision Speech and Signal Processing, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2012-10-15

    Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that

  8. The impact of androgen deprivation therapy on setup errors during external beam radiation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Onal, Cem; Dolek, Yemliha; Ozdemir, Yurday [Baskent University, Faculty of Medicine, Adana Dr. Turgut Noyan Research and Treatment Centre, Department of Radiation Oncology, Adana (Turkey)

    2017-06-15

    To determine whether setup errors during external beam radiation therapy (RT) for prostate cancer are influenced by the combination of androgen deprivation treatment (ADT) and RT. Data from 175 patients treated for prostate cancer were retrospectively analyzed. Treatment was as follows: concurrent ADT plus RT, 33 patients (19%); neoadjuvant and concurrent ADT plus RT, 91 patients (52%); RT only, 51 patients (29%). Required couch shifts without rotations were recorded for each megavoltage (MV) cone beam computed tomography (CBCT) scan, and corresponding alignment shifts were recorded as left-right (x), superior-inferior (y), and anterior-posterior (z). The nonparametric Mann-Whitney test was used to compare shifts by group. Pearson's correlation coefficient was used to measure the correlation of couch shifts between groups. Mean prostate shifts and standard deviations (SD) were calculated and pooled to obtain mean or group systematic error (M), SD of systematic error (Σ), and SD of random error (σ). No significant differences were observed in prostate shifts in any direction between the groups. Shifts on CBCT were all less than setup margins. A significant positive correlation was observed between prostate volume and the z-direction prostate shift (r = 0.19, p = 0.04), regardless of ADT group, but not between volume and x- or y-direction shifts (r = 0.04, p = 0.7; r = 0.03, p = 0.7). Random and systematic errors for all patient cohorts and ADT groups were similar. Hormone therapy given concurrently with RT was not found to significantly impact setup errors. Prostate volume was significantly correlated with shifts in the anterior-posterior direction only. (orig.) [German] Ziel war zu untersuchen, ob Konfigurationsfehler bei der externen Radiotherapie (RT) des Prostatakarzinoms durch die Kombination aus Androgendeprivationstherapie (ADT) und RT beeinflusst werden. Retrospektiv wurden die Daten von 175 wegen eines Prostatakarzinoms behandelten Patienten

  9. Minimal requirements for quality controls in radiotherapy with external beams; Controlli di qualita' essenziali in radioterapia con fasci esterni

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy. [Italian] Il gruppo di studio Assicurazione di qualita' in radioterapia dell'Istituto Superiore di Sanita' presenta le linee guida per la stesura dei protocolli di controllo di qualita' essenziali necessari a garantire un adeguato livello di accuratezza del trattamento radiante e rappresenta pertanto una parte essenziale del contributo fisico-dosimetrico globale di assicurazione di qualita' in radioterapia con fasci esterni.

  10. Hypoxic versus normoxic external-beam irradiation of cervical carcinoma combined with californium-252 neutron brachytherapy. Comparative treatment results of a 5-year randomized study.

    Science.gov (United States)

    Tacev, Taco; Vacek, Antonín; Ptácková, Blanka; Strnad, Vratislav

    2005-05-01

    The article focuses on the treatment and protective effects of hypoxyradiotherapy during external-beam irradiation of cervical carcinoma, including paraaortic lymph nodes, combining radiotherapy with californium-252 ((252)Cf) neutron brachytherapy. An analysis of treatment results, early and late side effects and complications is presented. From January 1989 to May 1997, 307 women with stage IIb and IIIb cervical carcinoma, treated with (252)Cf neutron brachytherapy, were randomly divided into two groups and treated with external-beam irradiation to the paraaortic lymph nodes as follows: 155 patients (59 with stage IIb, 96 with stage IIIb) were treated by external-beam irradiation administered as a 60-Gy dose applied under conditions of acute hypoxia; 77 patients (30 with stage IIb and 47 with stage IIIb) received extended-field irradiation up to L4 and 78 patients (29 with stage IIb and 49 with stage IIIb) up to T12. 152 patients (58 with stage IIb, 94 with stage IIIb) were treated by external-beam irradiation administered as a 40-Gy dose applied under normal oxygenation conditions. 73 patients (29 with stage IIb and 44 with stage IIIb) received extended-field irradiaton up to L4 and 79 patients (29 with stage IIb and 50 with stage IIIb) up to T12. The same 56 Gy-equivalent (eq) doses at point A and 19 Gy-eq doses at point B were applied intracavitarily in both groups. The total radiation doses at points A and B were 99 and 79 Gy-eq, respectively, for patients treated with external-beam irradiation to 60 Gy under conditions of acute hypoxia. For patients treated with external-beam irradiation to 40 Gy under normal oxygenation conditions, the doses at points A and B were 85 and 59 Gy-eq, respectively. The 5-year overall survival rate for all patients (stages IIb and IIIb) was 7.0% better for patients treated in acute hypoxia than for patients treated under normal oxygenation conditions (78.7% vs. 71.7% [p < 0.16]). The 5-year metastases-free survival rate was

  11. Clinical assessment of 252Californium neutron intracavitary brachytherapy using a two-channel Y applicator combined with external beam radiotherapy for endometrial cancer

    OpenAIRE

    Qian Zhou; Cheng Tang; Ke-Wei Zhao; Yan-Li Xiong; Shu Chen; Wen-Jing Xu; Xin Lei

    2016-01-01

    OBJECTIVE: The aim of this study was to determine the efficacy of 252Californium neutron intracavitary brachytherapy using a two-channel Y applicator combined with external beam radiotherapy for the treatment of endometrial cancer. METHODS: Thirty-one patients with stage I-III endometrial cancer were recruited for this study. The stage I patients received only 252Californium neutron intracavitary brachytherapy with a two-channel applicator. The stage II and III patients received both 252Cali...

  12. Movement of the cervix in after-loading brachytherapy: implications for designing external-beam radiotherapy boost fields.

    Science.gov (United States)

    Hombaiah, U; Blake, P; Bidmead, M

    2006-05-01

    Women with invasive carcinoma of the cervix treated by chemo-radiotherapy and brachytherapy may also receive a pelvic sidewall boost using a midline shield (MLS). The purpose of this study was to assess the usefulness of implanted gold grains in detecting the movement of the cervix caused by the insertion of low-dose-rate brachytherapy applicators, and its implications in designing the MLS. The medical records of 42 women with various stages of cervical carcinoma, who were treated by radical chemo-radiotherapy, were reviewed. All of these women underwent examination under anaesthesia (EUA) and a gold-grain insertion to demarcate the vaginal tumour extent, in the antero-posterior and lateral planes, before starting external-beam radiotherapy. The isocentric orthogonal films (simulator films) of external radiotherapy and brachytherapy were compared to assess the change in position of the gold grains and the consequences for the design of the MLS for parametrial and pelvic sidewall boosts. A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. The median shift of the midline, right and left lateral gold grains was 4.5, 5 and 7 mm in the x axis, whereas it was 10, 8 and 9.5 mm in the y axis, respectively. The median shift in the x and y axes was 5.5 and 9 mm, ranging from 1 to 40 mm and 1 to 45 mm, respectively. The gold grains were shifted cranially in 34 (80%) and laterally in 29 (69%) women. Thirty-two women (76.2%) received parametrial boost radiotherapy, of which 25 (59.5%) women had a customised, pear-shaped shield, and the remaining seven (16.7%) had a straight-sided, rectangular MLS. Four women (9.5%) relapsed locally, and three of them had been treated using a customised shield. In two of these four women, there was an absolute under-dosage of the central pelvis at the tip of the intra-uterine tube by 50% of the parametrial boost dose (5.4 Gy/3 fractions/3 days). Insertion of the gold grains

  13. SU-D-BRA-06: Investigation of Prostate Intrafractional Motion during External Beam Radiotherapy for a Large Patient Population.

    Science.gov (United States)

    Tong, X; Chen, X; Li, J; Lin, M; Chen, L; Xu, Q; Ma, C

    2012-06-01

    To analyze and report prostate intrafractional motion recorded online during external beam radiotherapy and to provide guidance for advanced prostate IMRT. Prostate intrafractional motion during IMRT and RapidARC treatments was tracked and recorded using a Calypso 4D-localization system. Data for 8600 treatment fractions of 230 prostate patients was analyzed. The percentage of treatment fractions, the fractional treatment time, and the fractional time of any individual minute were analyzed separately for prostate movements greater than the thresholds (2, 3, 5 and 7mm). The percentages of fractions in which prostate shifted more than the thresholds for a duration >10 seconds are 66.2%, 34.9%, 8.9% and 2.6% (57.9%, 27.9%, 5.2% and 0.8% for >30 seconds duration), respectively. For 10 patients who exhibited the largest motion, the percentages are 95.2%, 76.0%, 43.2% and 14.7% (91.3%, 72.4%, 36.3% and 6.0% for >30 seconds duration). The fractional time for motion larger than the thresholds is 27.8%, 10.7%, 1.6% and 0.3% (56.2%, 33.7%, 11.2% and 2.1% for these patients). The posterior-direction motion is significantly higher than those in other directions. The fractional time of an individual minute with shift >3mm is higher at the 10th minute than at the 5th minute (20% vs. 10%) after the initial setup. For treatments completed within 5 minutes, the average fractional time with motion >3mm was lower than those within 10 minutes (4% vs. 12%). Irregular movements were observed most likely in the first minute after patient's setup, which were 12% and 7% among all fractions with movements >2mm and >3mm, respectively. The prostate intrafractional motion was within 3mm for most treatment fractions. However, larger movements were observed for some patients, who require real-time corrections or larger treatment margins. The results indicate that it is beneficial if the treatment can be completed within 5 minutes. © 2012 American Association of Physicists in Medicine.

  14. Carcinoma of the cervix: analysis of complications after primary external beam radiation and Ir-192 HDR brachytherapy

    International Nuclear Information System (INIS)

    Kapp, Karin S.; Stuecklschweiger, Georg F.; Kapp, Daniel S.; Poschauko, Johann; Pickel, Hellmuth; Hackl, Arnulf

    1997-01-01

    Background and purpose: There is still a concern that the use of HDR brachytherapy might result in an increase of late tissue damage. This retrospective study evaluates the incidence and severity of late complications in patients with carcinoma of the cervix who underwent combined external beam radiation (EBR) and Ir-192 HDR brachytherapy and attempts to identify pretreatment and treatment parameters correlating with late complications. Material and methods: Between 1985 and 1992, 161 patients with carcinoma of the cervix (FIGO stages IB-IVB) received EBR to the pelvis (ave. max. dose 48.8 Gy) followed by 1-6 Ir-192 HDR placements (median 2). Doses to point A ranged from 8.5 to 38.7 Gy (median 17 Gy). Parameters examined included age, diabetes, obesity, history of inflammatory bowel disease or diverticulitis, prior surgery, hemoglobin level, FIGO stage, EBR dose, technique and daily dose fraction, number of HDR treatments and total dose to point A, maximum doses to bladder and rectum delivered by brachytherapy and cumulative dose to point A. Median follow-up for all patients was 37 months. Complications were rated using an in-house scoring system and according to the French-Italian Glossary (FIG). Results: Actuarial 5-year survival was 93%, 57%, 46%, and 0% for stages IB, II, IIIB, and IV, respectively. Of 161 patients, 11% developed moderate and 3.7% severe sequelae (FIG: 2.5%, 3.7%). Since some patients experienced more than one complication, the overall incidence was 13.6% and 4.9% (FIG: 3.1%, 4.9%) with respective 5-year actuarial rates of 14% and 5% for moderate, and 2% and 8% for severe bowel and genitourinary tract complications (FIG: 3.5%, 0, and 2%, 8%). All severe bowel complications occurred within 1.5 years whereas urinary tract sequelae continued to develop throughout the follow-up period. FIGO stage was associated with a significant increase in late sequelae (P=0.015). Analysis of the remaining pretreatment and treatment parameters failed to reveal

  15. Benefit of Adjuvant Brachytherapy Versus External Beam Radiation for Early Breast Cancer: Impact of Patient Stratification on Breast Preservation

    International Nuclear Information System (INIS)

    Smith, Grace L.; Jiang, Jing; Buchholz, Thomas A.; Xu, Ying; Hoffman, Karen E.; Giordano, Sharon H.; Hunt, Kelly K.; Smith, Benjamin D.

    2014-01-01

    Purpose: Brachytherapy after lumpectomy is an increasingly popular breast cancer treatment, but data concerning its effectiveness are conflicting. Recently proposed “suitability” criteria guiding patient selection for brachytherapy have never been empirically validated. Methods: Using the Surveillance, Epidemiology, and End Results–Medicare linked database, we compared women aged 66 years or older with invasive breast cancer (n=28,718) or ductal carcinoma in situ (n=7229) diagnosed from 2002 to 2007, treated with lumpectomy alone, brachytherapy, or external beam radiation therapy (EBRT). The likelihood of breast preservation, measured by subsequent mastectomy risk, was compared by use of multivariate proportional hazards, further stratified by American Society for Radiation Oncology (ASTRO) brachytherapy suitability groups. We compared 1-year postoperative complications using the χ 2 test and 5-year local toxicities using the log-rank test. Results: For patients with invasive cancer, the 5-year subsequent mastectomy risk was 4.7% after lumpectomy alone (95% confidence interval [CI], 4.1%-5.4%), 2.8% after brachytherapy (95% CI, 1.8%-4.3%), and 1.3% after EBRT (95% CI, 1.1%-1.5%) (P<.001). Compared with lumpectomy alone, brachytherapy achieved a more modest reduction in adjusted risk (hazard ratio [HR], 0.61; 95% CI, 0.40-0.94) than achieved with EBRT (HR, 0.22; 95% CI, 0.18-0.28). Relative risks did not differ when stratified by ASTRO suitability group (P=.84 for interaction), although ASTRO “suitable” patients did show a low absolute subsequent mastectomy risk, with a minimal absolute difference in risk after brachytherapy (1.6%; 95% CI, 0.7%-3.5%) versus EBRT (0.8%; 95% CI, 0.6%-1.1%). For patients with ductal carcinoma in situ, EBRT maintained a reduced risk of subsequent mastectomy (HR, 0.40; 95% CI, 0.28-0.55; P<.001), whereas the small number of patients treated with brachytherapy (n=179) precluded definitive comparison with lumpectomy alone. In

  16. Urodynamic changes at 18 months post-therapy in patients treated with external beam radiotherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Choo, Richard; Do, Viet; Herschorn, Sender; DeBoer, Gerrit; Danjoux, Cyril; Morton, Gerard; Cheng, Chun Hung; Barak, Inna; Preiner, John

    2002-01-01

    Purpose: To quantify the effect of radiotherapy (RT) on urodynamics at 18 months post-therapy, using urodynamic study, in prostate cancer patients undergoing definitive external beam RT. Methods and Materials: A total of 17 patients with clinically localized prostate cancer were accrued into a single-arm prospective study. Fifteen of 17 patients completed scheduled multichannel video-urodynamic study at baseline as well as 3 and 18 months after RT. Baseline quantitative urodynamic parameters were compared with those at 18 months post-RT to assess the nature and extent of urodynamic change brought about by RT. These quantitative changes were further correlated to the change in self-assessed qualitative urinary function measured by International Prostate Symptom Score (IPSS), Quality of Life assessment index (QoL), and urinary functional inquiry. Results: The statistically significant quantitative changes detected by the urodynamic study at 18 months post-RT were decrease in bladder capacity and bladder volume at first sensation in both the supine and upright position, and reduction in bladder volume at desire to void in the supine position. In our cohort, the mean reduction in bladder capacity was 100 mL in the supine position and 54 mL in the upright position. No statistically significant change was observed with regard to pressure, maximum flow rate, voided volume, or postvoid residual volume. Furthermore, there was no statistically significant change in bladder compliance, bladder instability, or bladder outlet obstruction. No statistically significant change in self-assessed qualitative urological function was observed between baseline and 18 months post-RT, measured by the 3 parameters (IPSS, QoL, and urinary frequency over 24 h). Conclusions: This is the first quantitative study that prospectively evaluated the effect of RT on urodynamics in prostate cancer patients receiving definitive RT. The statistically significant changes at 18 months post-RT were

  17. Outcomes of Patients With Non-Hodgkin's Lymphoma Treated With Bexxar With or Without External-Beam Radiotherapy

    International Nuclear Information System (INIS)

    Smith, Kristy; Byer, Gracie; Morris, Christopher G.; Kirwan, Jessica M.; Lightsey, Judith; Mendenhall, Nancy P.; Hoppe, Bradford S.; Lynch, James; Olivier, Kenneth

    2012-01-01

    Purpose: To compare the efficacy and toxicity of external-beam radiotherapy (EBRT) to sites of bulky lymphadenopathy in patients with chemotherapy-refractory low-grade non-Hodgkin’s lymphoma (NHL) immediately before receiving Bexxar (tositumomab and 131 I) vs. in patients receiving Bexxar alone for nonbulky disease. Methods and Materials: Nineteen patients with chemotherapy-refractory NHL were treated with Bexxar at our institution (University of Florida, Gainesville, FL) from 2005 to 2008. Seventeen patients had Grade 1–2 follicular lymphoma. Ten patients received a median of 20 Gy in 10 fractions to the areas of clinical involvement, immediately followed by Bexxar (EBRT + Bexxar); 9 patients received Bexxar alone. The median tumor sizes before EBRT + Bexxar and Bexxar alone were 4.8 cm and 3.3 cm, respectively. All 5 patients with a tumor diameter >5 cm were treated with EBRT + Bexxar. A univariate analysis of prognostic factors for progression-free survival (PFS) was performed. Results: The median follow-up was 2.3 years for all patients and 3.1 years for 12 patients alive at last follow-up. Of all patients, 79% had a partial or complete response; 4 of the 8 responders in the EBRT + Bexxar group achieved a durable response of over 2 years, including 3 of the 5 with tumors >5 cm. Three of 9 patients treated with Bexxar alone achieved a durable response over 2 years. Actuarial estimates of 3-year overall survival and PFS for EBRT + Bexxar and Bexxar alone were 69% and 38% and 62% and 33%, respectively. The median time to recurrence after EBRT + Bexxar and Bexxar alone was 9 months. Having fewer than 4 involved lymph-node regions was associated with superior PFS at 3 years (63% vs. 18%). There was no Grade 4 or 5 complications. Conclusions: Adding EBRT immediately before Bexxar produced PFS equivalent to that with Bexxar alone, despite bulkier disease. Hematologic toxicity was not worsened. EBRT combined with Bexxar adds a safe and effective therapeutic

  18. Low-dose external beam radiotherapy for greater trochanteric pain syndrome. Target volume definition and treatment outcome

    International Nuclear Information System (INIS)

    Kaltenborn, Alexander; Carl, Ulrich Martin; Hinsche, Tanja; Nitsche, Mirko; Hermann, Robert Michael

    2017-01-01

    Low-dose external beam radiotherapy (ED-EBRT) is frequently used in the therapy of refractory greater trochanteric pain syndrome (GTPS). As studies reporting treatment results are scarce, we retrospectively analyzed our own patient collectives. In all, 60 patients (74 hips) received LD-EBRT (6 x 0.5 Gy in 29 hips, 6 x 1 Gy in 45). The endpoint was the patient's reported subjective response to treatment. The influence of different patient and treatment characteristics on treatment outcome was investigated. At the end of LD-EBRT, 69% reported partial remission, 4% complete remission, no change 28%. A total of 3 months later (n = 52 hips), the results were 37, 33, and 30% and 18 months after LD-EBRT (n = 47) 21, 51, and 28%. In univariate analysis ''inclusion of the total femoral head into the PTV'' and ''night pain before LD-EBRT'' were correlated with symptom remission at the end of LD-EBRT, while ''initial increase in pain during LD-EBRT'' was significantly associated with treatment failure. In multivariable modeling ''initial increase in pain'' was identified as a risk factor for treatment failure (p = 0.007; odds ratio [OR] 0.209; 95% confidence interval [CI] 0.048-0.957), while ''night pain'' was an independent factor for remission (p = 0.038; OR 3.484; 95% CI 1.004-12.6). Three months after LD-EBRT ''night pain'' and ''inclusion of the complete femoral neck circumference into the PTV'' were predictive for remission. LD-EBRT represents a useful treatment option for patients suffering from GTPS. Three months after therapy two-thirds of the patients reported a partial or complete symptom remission. Especially patients who suffered from nocturnal pain seemed to benefit. Treatment appeared to be more effective when the entire circumference of the femoral neck was encompassed. (orig.) [de

  19. Phase II Radiation therapy oncology group trial of weekly paclitaxel and conventional external beam radiation therapy for supratentorial glioblastoma multiforme

    International Nuclear Information System (INIS)

    Langer, Corey J.; Ruffer, James; Rhodes, Harker; Paulus, Rebecca; Murray, Kevin; Movsas, Benjamin; Curran, Walter

    2001-01-01

    Purpose: Fractionated external beam radiotherapy (EBRT) ± carmustine (BCNU) is the standard of care for patients with glioblastoma multiforme (GBM), but survival results remain poor. Preclinical studies indicate synergy between RT and paclitaxel (TAX) in astrocytoma cell lines. Phase I studies in GBM have demonstrated a maximum tolerated dose for TAX of 225 mg/m 2 /3 h/week x 6, during EBRT, with no exacerbation of typical RT-induced toxicities. The Radiation Therapy Oncology Group (RTOG) therefore mounted a Phase II study to determine the feasibility and efficacy of conventional EBRT and concurrent weekly TAX at its MTD. Patients and Methods: Sixty-two patients with histologic diagnosis of GBM were enrolled from 8/16/96 through 3/21/97 in a multi-institutional Phase II trial of EBRT and TAX 225 mg/m 2 /3 h (1-3 h before EBRT), administered the first treatment day of each RT week. Total EBRT dose was 60 Gy (200 cGy/fraction), 5 days per week. A smaller treatment field, to include gross disease plus a margin only, was used after 46 Gy. Results: Sixty-one patients (98%) were evaluable. Median age was 55 years (range, 28-78). Seventy-four percent were ≥50 years. Recursive partitioning analysis (RPA) Classes III, IV, V, VI included 10 (17%), 21 (34%), 25 (41%), and 5 (8%) patients, respectively. Gross total resection was performed in only 16%. There was no Grade 3 or 4 neutropenia or thrombocytopenia. Hypersensitivity reactions precluding further use of TAX occurred in 4 patients. There were 2 instances of late neurotoxicity (4% Grade 3 or 4). Ninety-one percent of patients received treatment per protocol. Seventy-seven percent completed prescribed treatment (6 weeks). Of 35 patients with measurable disease, CR/PR was observed in 23%, MR in 17%, and SD in 43%. Seventeen percent demonstrated progression at first follow-up. Median potential follow-up time is 20 months. Median survival is 9.7 months, with median survivals for RPA classes III, IV, V, and VI of 16.3, 10

  20. [Comparative study of radical prostatectomy versus external beam radiotherapy (75.6 Gy) combined with hormone therapy for prostate cancer of intermediate D'Amico risk classification].

    Science.gov (United States)

    Boissier, R; Karsenty, G; Muracciole, X; Daniel, L; Delaporte, V; Maurin, C; Coulange, C; Lechevallier, E

    2013-09-01

    Thirty-three percent of the localized cancers belongs initially to the group of intermediate risk of D'Amico. The standard treatments validated by the French Association of Urology are the radical prostatectomy and the external beam radiotherapy. We retrospectively compared the carcinologic results of the radical prostatectomy±adjuvant treatment (RP) and the external beam radiotherapy combining high dose (75.6 Gy) and short hormonotherapy (RH), in the treatment of intermediate risk prostate cancer. The series consisted of 143 patients treated between 2000 and 2006 in the department of Urology and Kidney transplantation of the Conception Hospital, Marseilles. The main assessment criteria was the survival without biological recurrence (SBR). The median follow-up was 90 months [59-51]. The 5 years and 8 years SBR were 85% and 73% in the RH group, versus 74% and 65% with RP (P=0.196). There was a significant difference between the series: on the age of diagnosis (63.9 versus 73.3 years, P<0.001), the Charlson score of comorbidity (2 versus 3, P<0.001) and the number of intermediate criteria per patients (one intermediate criteria: RP 74% versus 57%, P<0.01). According to our study, there was no superiority of the radical prostatectomy±adjuvant treatment or the external radiotherapy combining high dose and concomitant short hormonotherapy on the survival without biological recurrence at 5 and 8 years. Many studies confirm that a concomitant hormonotherapy increases the carcinologic control, even with a high rate external beam radiotherapy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vásquez Osorio, Eliana M., E-mail: e.vasquezosorio@erasmusmc.nl; Kolkman-Deurloo, Inger-Karine K.; Schuring-Pereira, Monica; Zolnay, András; Heijmen, Ben J. M.; Hoogeman, Mischa S. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam 3075 (Netherlands)

    2015-01-15

    Purpose: In the treatment of cervical cancer, large anatomical deformations, caused by, e.g., tumor shrinkage, bladder and rectum filling changes, organ sliding, and the presence of the brachytherapy (BT) applicator, prohibit the accumulation of external beam radiotherapy (EBRT) and BT dose distributions. This work proposes a structure-wise registration with vector field integration (SW+VF) to map the largely deformed anatomies between EBRT and BT, paving the way for 3D dose accumulation between EBRT and BT. Methods: T2w-MRIs acquired before EBRT and as a part of the MRI-guided BT procedure for 12 cervical cancer patients, along with the manual delineations of the bladder, cervix-uterus, and rectum-sigmoid, were used for this study. A rigid transformation was used to align the bony anatomy in the MRIs. The proposed SW+VF method starts by automatically segmenting features in the area surrounding the delineated organs. Then, each organ and feature pair is registered independently using a feature-based nonrigid registration algorithm developed in-house. Additionally, a background transformation is calculated to account for areas far from all organs and features. In order to obtain one transformation that can be used for dose accumulation, the organ-based, feature-based, and the background transformations are combined into one vector field using a weighted sum, where the contribution of each transformation can be directly controlled by its extent of influence (scope size). The optimal scope sizes for organ-based and feature-based transformations were found by an exhaustive analysis. The anatomical correctness of the mapping was independently validated by measuring the residual distances after transformation for delineated structures inside the cervix-uterus (inner anatomical correctness), and for anatomical landmarks outside the organs in the surrounding region (outer anatomical correctness). The results of the proposed method were compared with the results of the

  2. Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer

    International Nuclear Information System (INIS)

    Vásquez Osorio, Eliana M.; Kolkman-Deurloo, Inger-Karine K.; Schuring-Pereira, Monica; Zolnay, András; Heijmen, Ben J. M.; Hoogeman, Mischa S.

    2015-01-01

    Purpose: In the treatment of cervical cancer, large anatomical deformations, caused by, e.g., tumor shrinkage, bladder and rectum filling changes, organ sliding, and the presence of the brachytherapy (BT) applicator, prohibit the accumulation of external beam radiotherapy (EBRT) and BT dose distributions. This work proposes a structure-wise registration with vector field integration (SW+VF) to map the largely deformed anatomies between EBRT and BT, paving the way for 3D dose accumulation between EBRT and BT. Methods: T2w-MRIs acquired before EBRT and as a part of the MRI-guided BT procedure for 12 cervical cancer patients, along with the manual delineations of the bladder, cervix-uterus, and rectum-sigmoid, were used for this study. A rigid transformation was used to align the bony anatomy in the MRIs. The proposed SW+VF method starts by automatically segmenting features in the area surrounding the delineated organs. Then, each organ and feature pair is registered independently using a feature-based nonrigid registration algorithm developed in-house. Additionally, a background transformation is calculated to account for areas far from all organs and features. In order to obtain one transformation that can be used for dose accumulation, the organ-based, feature-based, and the background transformations are combined into one vector field using a weighted sum, where the contribution of each transformation can be directly controlled by its extent of influence (scope size). The optimal scope sizes for organ-based and feature-based transformations were found by an exhaustive analysis. The anatomical correctness of the mapping was independently validated by measuring the residual distances after transformation for delineated structures inside the cervix-uterus (inner anatomical correctness), and for anatomical landmarks outside the organs in the surrounding region (outer anatomical correctness). The results of the proposed method were compared with the results of the

  3. Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy

    International Nuclear Information System (INIS)

    Cheung, Rex; Tucker, Susan L.; Lee, Andrew K.; Crevoisier, Renaud de; Dong Lei; Kamat, Ashish; Pisters, Louis; Kuban, Deborah

    2005-01-01

    Purpose: In this era of dose escalation, the benefit of higher radiation doses for low-risk prostate cancer remains controversial. For intermediate-risk patients, the data suggest a benefit from higher doses. However, the quantitative characterization of the benefit for these patients is scarce. We investigated the radiation dose-response relation of tumor control probability in low-risk and intermediate-risk prostate cancer patients treated with radiotherapy alone. We also investigated the differences in the dose-response characteristics using the American Society for Therapeutic Radiology and Oncology (ASTRO) definition vs. an alternative biochemical failure definition. Methods and materials: This study included 235 low-risk and 387 intermediate-risk prostate cancer patients treated with external beam radiotherapy without hormonal treatment between 1987 and 1998. The low-risk patients had 1992 American Joint Committee on Cancer Stage T2a or less disease as determined by digital rectal examination, prostate-specific antigen (PSA) levels of ≤10 ng/mL, and biopsy Gleason scores of ≤6. The intermediate-risk patients had one or more of the following: Stage T2b-c, PSA level of ≤20 ng/mL but >10 ng/mL, and/or Gleason score of 7, without any of the following high-risk features: Stage T3 or greater, PSA >20 ng/mL, or Gleason score ≥8. The logistic models were fitted to the data at varying points after treatment, and the dose-response parameters were estimated. We used two biochemical failure definitions. The ASTRO PSA failure was defined as three consecutive PSA rises, with the time to failure backdated to the mid-point between the nadir and the first rise. The second biochemical failure definition used was a PSA rise of ≥2 ng/mL above the current PSA nadir (CN + 2). The failure date was defined as the time at which the event occurred. Local, nodal, and distant relapses and the use of salvage hormonal therapy were also failures. Results: On the basis of the

  4. Hypoxic versus normoxic external-beam irradiation of cervical carcinoma combined with californium-252 neutron brachytherapy. Comparative treatment results of a 5-year randomized study

    International Nuclear Information System (INIS)

    Tacev, T.; Ptackova, B.; Vacek, A.; Strnad, V.

    2005-01-01

    Purpose: the article focuses on the treatment and protective effects of hypoxyradiotherapy during external-beam irradiation of cervical carcinoma, including paraaortic lymph nodes, combining radiotherapy with californium-252 ( 252 Cf) neutron brachytherapy. An analysis of treatment results, early and late side effects and complications is presented. Results: the 5-year overall survival rate for all patients (stages IIb and IIIb) was 7.0% better for patients treated in acute hypoxia than for patients treated under normal oxygenation conditions (78.7% vs. 71.7% [p < 0.16]). The 5-year metastases-free survival rate was better by 11.7% for stage IIIb patients in the hypoxyradiotherapy group with extended field up to T12 as compared to patients with extended field up to L4 (97.4% vs. 85.7% [p < 0.05]). Comparison of metastases-free survival rate of stage IIIb patients after external-beam irradiation with extended field up to T12 in hypoxic condition versus normoxic condition showed a 12% better result for patients in hypoxic condition (97.4% vs. 85.4% [p < 0.04]). Occurrences of symptomatic radiation-induced reactions during or shortly after irradiation were more frequently observed in patients treated with a lower dose under normoxic conditions. During the period of 6-12 years after treatment there were no changes in the frequencies of occurrences of late effects and complications. Conclusion: the importance of the protective effects of hypoxyradiotherapy for dose escalation in external-beam irradiation of cervical carcinoma, including paraaortic lymph nodes, with regard to an improvement of the cure rates of metastases in paraaortic lymph nodes has been confirmed. (orig.)

  5. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  6. A consensus-based guideline defining clinical target volume for primary disease in external beam radiotherapy for intact uterine cervical cancer

    International Nuclear Information System (INIS)

    Toita, Takafumi; Ohno, Tatsuya; Kaneyasu, Yuko

    2011-01-01

    The objective of this study was to develop a consensus-based guideline to define clinical target volume for primary disease (clinical target volume primary) in external beam radiotherapy for intact uterine cervical cancer. The working subgroup of the Japan Clinical Oncology Group (JCOG) Radiation Therapy Study Group began developing a guideline for primary clinical target volume in November 2009. The group consisted of 10 radiation oncologists and 2 gynecologic oncologists. The process started with comparing the contouring on computed tomographic images of actual cervical cancer cases among the members. This was followed by a comprehensive literature review that included primary research articles and textbooks as well as information on surgical procedures. Extensive discussion occurred in face-to-face meetings (three occasions) and frequent e-mail communications until a consensus was reached. The working subgroup reached a consensus on the definition for the clinical target volume primary. The clinical target volume primary consists of the gross tumor volume, uterine cervix, uterine corpus, parametrium, vagina and ovaries. Definitions for these component structures were determined. Anatomical boundaries in all directions were defined for the parametrium. Examples delineating these boundaries were prepared for the posterior border of the parametrium for various clinical situations (id est (i.e.) central tumor bulk, degree of parametrial involvement). A consensus-based guideline defining the clinical target volume primary was developed for external beam radiotherapy for intact uterine cervical cancer. This guideline will serve as a template for radiotherapy protocols in future clinical trials. It may also be used in actual clinical practice in the setting of highly precise external beam radiotherapy, including intensity-modulated radiotherapy. (author)

  7. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

    Science.gov (United States)

    Gibbons, John P; Antolak, John A; Followill, David S; Huq, M Saiful; Klein, Eric E; Lam, Kwok L; Palta, Jatinder R; Roback, Donald M; Reid, Mark; Khan, Faiz M

    2014-03-01

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D'0, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D'0 = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D'0 ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of dm, with D'0 = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  8. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, John P., E-mail: john.gibbons@marybird.com [Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana 70809 (United States); Antolak, John A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Followill, David S. [Department of Radiation Physics, UT M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania 15232 (United States); Klein, Eric E. [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Lam, Kwok L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Palta, Jatinder R. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Roback, Donald M. [Department of Radiation Oncology, Cancer Centers of North Carolina, Raleigh, North Carolina 27607 (United States); Reid, Mark [Department of Medical Physics, Fletcher-Allen Health Care, Burlington, Vermont 05401 (United States); Khan, Faiz M. [Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-03-15

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  9. Six fractions per week of external beam radiotherapy and high-dose-rate brachytherapy for carcinoma of the uterine cervix: A phase I/II study

    International Nuclear Information System (INIS)

    Yoon, Sang Min; Huh, Seung Jae; Park, Won; Lee, Jeung Eun; Park, Young Je; Nam, Hee Rim; Lim, Do Hoon; Ahn, Yong Chan

    2006-01-01

    Purpose: This study evaluated the treatment results of external beam radiotherapy administered in six fractions per week and high-dose-rate (HDR) brachytherapy for the treatment of cervical cancer. Methods and Materials: From July 2000 to July 2003, 43 patients were enrolled in this study. The patients received 45 Gy from a 10-MV photon beam using four-field box or anterior-posterior beams. Parametrial regions and the pelvic side walls were boosted with up to 50.4 Gy using a midline block. The daily fraction dose was 1.8 Gy administered in six-weekly fractions, from Monday to Saturday. HDR brachytherapy was also delivered at doses of 24 Gy to point A in six fractions twice a week. The median follow-up time was 37 months (range, 9-60 months). Results: The median overall treatment time was 51 days for all patients (range, 44-62 days). Thirty-four patients (79.1%) achieved complete remission and 8 (18.6%) achieved partial remission after radiotherapy. Locoregional recurrence occurred in 5 patients (11.6%), and a distant metastasis was encountered in 6 patients (13.9%). The 3-year overall survival, locoregional, and distant metastasis-free survival rates were 74.7%, 87.8%, and 84.7%, respectively. Grade 2 and 3 late rectal complications were encountered in 3 (6.5%) and 1 (2.2%), respectively. There were no Grade 3 late bladder complications. Conclusions: Six fractions per week of external beam radiotherapy and HDR brachytherapy is an effective treatment for patients with a carcinoma of the uterine cervix and can be used as a possible alternative to concomitant chemoradiotherapy in elderly patients or in patients with co-morbidity

  10. External-beam PIXE spectrometry for the study of Punic jewellery (SW Spain): The geographical provenance of the palladium-bearing gold

    Energy Technology Data Exchange (ETDEWEB)

    Ontalba Salamanca, M.A. [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda. de la Universidad s/n., 10071 Caceres (Spain)]. E-mail: ontalba@unex.es; Gomez-Tubio, B. [Centro Nacional de Aceleradores, Sevilla (Spain); Ortega-Feliu, I. [Centro Nacional de Aceleradores, Sevilla (Spain); Respaldiza, M.A. [Centro Nacional de Aceleradores, Sevilla (Spain); Luisa de la Bandera, M. [Departamento de Arqueologia, Universidad de Sevilla (Spain); Ovejero Zappino, G. [Cobre Las Cruces SA, Gerena, Sevilla (Spain); Bouzas, A. [Instituto Andaluz de Patrimonio Historico, Sevilla (Spain); Gomez-Moron, A. [Instituto Andaluz de Patrimonio Historico, Sevilla (Spain)

    2006-08-15

    This paper presents the study of a set of Punic gold items (400 B.C.), from the Museum of Cadiz (Spain). An external beam set-up has been employed for the absolutely non-destructive analysis of the objects. PIXE spectrometry has been performed in order to characterize the metallic alloys and the manufacturing techniques. Compositional differences have been found and soldering procedures have been identified. By comparison with the rings and other coetaneous jewellery, the presence of palladium in the bulk alloy of the earrings can be pointed out. The geographical provenance of the palladium-bearing gold is discussed based on geological and archaeological considerations.

  11. Olfactory Neuroblastoma Treated by Endoscopic Surgery Followed by Combined External Beam Radiation and Gamma Knife for Optic Nerve and Chiasm Sparing: A Case Report

    Directory of Open Access Journals (Sweden)

    Hansi Z. Jiang

    2011-01-01

    Full Text Available We describe the multimodality treatment regimen of a 53-year-old man diagnosed with olfactory neuroblastoma (Kadish stage C in the right nasal cavity extending into the ethmoid sinus and across the cribriform plate. Endoscopic surgery for tumor resection was followed by a combination of external beam radiotherapy and stereotactic radiosurgery boost with concurrent chemotherapy. The novel combination of dual radiation therapies allowed for the preservation of the nearby optic structures while providing an adequate dosage to a sufficient volume of the afflicted tissue.

  12. Californium versus cobalt brachytherapy combined with external-beam radiotherapy for IIB stage cervical cancer: long-term experience of a single institute

    OpenAIRE

    Janulionis, Ernestas; Valuckas, Konstantinas Povilas; Liukpetryte, Sarune; Samerdokiene, Vitalija; Atkocius, Vydmantas

    2015-01-01

    Purpose The purpose of this paper was to observe and compare long-term curative effects and complications of FIGO stage IIB cervical cancer patients (n = 232) treated with high-dose-rate (HDR) californium (252Cf) neutron or cobalt (60Co) photon intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT). Material and methods The EBRT dose to the small pelvis was 50 Gy in both groups. The brachytherapy component of 252Cf or 60Co was added in the 3rd week of EBRT, 5 fract...

  13. Understanding molecular markers in recurrent oral squamous cell carcinoma treated with chemoradiation

    Directory of Open Access Journals (Sweden)

    Seema Gupta

    2016-12-01

    Conclusion: Our results signifies that tumors over expressing Cyclin D1, EGFR and p53 are resistant to chemoradiation and are associated with increased risk of locoregional recurrence and metastasis in OSCC patients undergoing chemoradiation.

  14. Neoadjuvant preoperative chemoradiation in patients with pancreatic cancer

    International Nuclear Information System (INIS)

    Magnin, Valerie; Moutardier, Vincent; Giovannini, Marie-Helene; Lelong, Bernard; Giovannini, Marc; Viret, Frederic; Monges, Genevieve; Bardou, Valerie-Jeanne; Alzieu, Claude; Delpero, Jean-Robert

    2003-01-01

    Purpose: To assess the toxicity and efficacy of preoperative chemoradiation in pancreatic cancer. Methods and Materials: Between November 1996 and December 2001, 32 patients with biopsy-proven pancreatic adenocarcinoma (28 head; 4 body) were treated by chemoradiation consisting of either split-course therapy (two courses of 15 Gy separated by a 2-week break, n = 10) or standard-fractionation therapy (45 Gy during 5 weeks, n 22). Concurrent chemotherapy included continuous infusion of 5-fluorouracil and a cisplatin bolus. Pancreatic resection was scheduled for 4-6 weeks after completion of chemoradiation treatment. Results: All 32 patients completed the chemoradiation protocol. Only 2 cases of Grade 3 toxicity (weight loss, vomiting) and one fatal Grade 4 infection occurred. Of the 32 patients, 19 underwent curative resection. Two patients had a complete pathologic response. One patient died 36 months after diagnosis of late treatment-related toxicity (acute superior mesenteric artery thrombosis) with no evidence of disease. The 2-year overall survival rate for the entire group and the resected patients was 37.3% (95% confidence interval 18.2-56.4%) and 59.3% (95% confidence interval 34.1-84.9%), respectively. Conclusion: Preoperative chemoradiation with 5-fluorouracil and cisplatin is feasible and promising

  15. External audits of therapeutic photon beams in non-reference conditions. Mailed dosimetry checks with the EC multipurpose phantom

    International Nuclear Information System (INIS)

    Gomola, I.; Huyskens, D.; Dutreix, A.

    2001-01-01

    In this paper various methods for dosimetric calculation using the multipurpose solid phantom are presented. The present study indicates that the mailed multipurpose solid phantom is a useful tool to check the dose calculation of treatment planning systems, because a large number of dosimetric parameters per beam can be checked. (authors)

  16. Impact of age on quality of life in patients with localized prostate cancer treated with high-dose rate brachytherapy combined with external beam radiotherapy.

    Science.gov (United States)

    Kikkawa, Kazuro; Iba, Akinori; Kohjimoto, Yasuo; Noda, Yasutaka; Sonomura, Tetsuo; Hara, Isao

    2018-02-04

    To evaluate age-related quality of life changes in patients with localized prostate cancer treated by high-dose rate brachytherapy combined with external beam radiation therapy. A total of 172 patients with clinically localized prostate cancer were categorized to age groups <75 years and ≥75 years. Changes in their quality of life were evaluated using the Japanese version of Medical Outcome Study 8-Items Short Form Health Survey, Expanded Prostate Cancer Index Composite and International Index of Erectile Function-5 at baseline, and followed up to 24 months after treatment. There were no significant differences in Medical Outcome Study 8-Items Short Form Health Survey scores, and urinary and bowel scores of the Expanded Prostate Cancer Index Composite for older men after treatment. International Index of Erectile Function-5 summary scores were significantly decreased in both groups. Although sexual function and sexual bother scores were decreased in patients aged <75 years, these scores were maintained in patients aged ≥75 years. Quality of life of prostate cancer patients undergoing high-dose rate brachytherapy combined with external beam radiation therapy does not seem to be significantly affected by age. © 2018 The Japanese Urological Association.

  17. External beam radiotherapy with intraluminal brachytherapy for superficial esophageal cancers. The analyses of safety, acute and late adverse effects of combination therapy

    Energy Technology Data Exchange (ETDEWEB)

    Shikama, Naoto; Oguchi, Masahiko; Shinoda, Atsunori; Nishikawa, Atsushi; Sone, Shusuke [Shinshu Univ., Matsumoto, Nagano (Japan). School of Medicine; Okazaki, Youichi; Arakawa, Kazukiyo; Hirokawa, Yutaka

    2000-03-01

    Twenty patients with superficial esophageal cancers were treated with external beam radiotherapy and intraluminal brachytherapy. The median age was 75 years, and most patients had other systemic concomitant disease. The median dose of external beam radiotherapy was 60 Gy (40-60), and the median dose of brachytherapy was 10 Gy/4 fx. (10-18 Gy). The 2-year overall and disease-free survival rates were 90% and 94%, respectively. Acute adverse effects in the esophagus were relatively mild in most patients (Grade 0-1 according to RTOG Acute Radiation Morbidity Scoring Criteria), all patients were treated without interruption. Radiation induced pneumonitis (Grade 2) was found in one patient. Late adverse effects in the esophagus were mild in 18 patients without local recurrence (Grade 0; 14 patients, Grade 1; 4 patients, according to RTOG/European Organization for Research and Treatment of Cancer (EORTC) Late Radiation Morbidity Scoring Scheme). No severe late adverse effects including stenosis, bleeding and fistula was found. The swallowing of food was excellent in all patients. (author)

  18. Clinical assessment of 252Californium neutron intracavitary brachytherapy using a two-channel Y applicator combined with external beam radiotherapy for endometrial cancer

    Directory of Open Access Journals (Sweden)

    Qian Zhou

    2016-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the efficacy of 252Californium neutron intracavitary brachytherapy using a two-channel Y applicator combined with external beam radiotherapy for the treatment of endometrial cancer. METHODS: Thirty-one patients with stage I-III endometrial cancer were recruited for this study. The stage I patients received only 252Californium neutron intracavitary brachytherapy with a two-channel applicator. The stage II and III patients received both 252Californium neutron intracavitary brachytherapy using a two-channel applicator and parallel-opposed whole pelvic radiotherapy. RESULTS: The five-year local control rate was 80.6% (25/31, the overall survival rate was 51.6% (16/31, and the disease-free survival rate was 54.8% (17/31. The incidence of serious late complications was 12.9% (4/31. CONCLUSIONS: 252Californium neutron intracavitary brachytherapy using a two-channel applicator combined with external beam radiotherapy was effective for treating endometrial cancer and the incidence of serious late complications related to this combination was within an acceptable range.

  19. Low-dose external beam radiotherapy for greater trochanteric pain syndrome. Target volume definition and treatment outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kaltenborn, Alexander [Federal Armed Forces Hospital Westerstede, Department of Orthopedic and Trauma Surgery, Westerstede (Germany); Hannover Medical School, Core Facility Quality Management and Health Technology Assessment in Transplantation, Integrated Research and Treatment Center Transplantation (IFB-Tx), Hannover (Germany); Carl, Ulrich Martin; Hinsche, Tanja [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); Nitsche, Mirko [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); University of Schleswig Holstein, Campus Kiel, Department of Radiotherapy, Karl-Lennert Cancer Center, Kiel (Germany); Hermann, Robert Michael [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); Hannover Medical School, Department of Radiotherapy and Special Oncology, Hannover (Germany)

    2017-04-15

    Low-dose external beam radiotherapy (ED-EBRT) is frequently used in the therapy of refractory greater trochanteric pain syndrome (GTPS). As studies reporting treatment results are scarce, we retrospectively analyzed our own patient collectives. In all, 60 patients (74 hips) received LD-EBRT (6 x 0.5 Gy in 29 hips, 6 x 1 Gy in 45). The endpoint was the patient's reported subjective response to treatment. The influence of different patient and treatment characteristics on treatment outcome was investigated. At the end of LD-EBRT, 69% reported partial remission, 4% complete remission, no change 28%. A total of 3 months later (n = 52 hips), the results were 37, 33, and 30% and 18 months after LD-EBRT (n = 47) 21, 51, and 28%. In univariate analysis ''inclusion of the total femoral head into the PTV'' and ''night pain before LD-EBRT'' were correlated with symptom remission at the end of LD-EBRT, while ''initial increase in pain during LD-EBRT'' was significantly associated with treatment failure. In multivariable modeling ''initial increase in pain'' was identified as a risk factor for treatment failure (p = 0.007; odds ratio [OR] 0.209; 95% confidence interval [CI] 0.048-0.957), while ''night pain'' was an independent factor for remission (p = 0.038; OR 3.484; 95% CI 1.004-12.6). Three months after LD-EBRT ''night pain'' and ''inclusion of the complete femoral neck circumference into the PTV'' were predictive for remission. LD-EBRT represents a useful treatment option for patients suffering from GTPS. Three months after therapy two-thirds of the patients reported a partial or complete symptom remission. Especially patients who suffered from nocturnal pain seemed to benefit. Treatment appeared to be more effective when the entire circumference of the femoral neck was encompassed. (orig.) [German] In der Behandlung des

  20. Adaptive-Predictive Organ Localization Using Cone-Beam Computed Tomography for Improved Accuracy in External Beam Radiotherapy for Bladder Cancer

    International Nuclear Information System (INIS)

    Lalondrelle, Susan; Huddart, Robert; Warren-Oseni, Karole; Hansen, Vibeke Nordmark; McNair, Helen; Thomas, Karen; Dearnaley, David; Horwich, Alan; Khoo, Vincent

    2011-01-01

    Purpose: To examine patterns of bladder wall motion during high-dose hypofractionated bladder radiotherapy and to validate a novel adaptive planning method, A-POLO, to prevent subsequent geographic miss. Methods and Materials: Patterns of individual bladder filling were obtained with repeat computed tomography planning scans at 0, 15, and 30 minutes after voiding. A series of patient-specific plans corresponding to these time-displacement points was created. Pretreatment cone-beam computed tomography was performed before each fraction and assessed retrospectively for adaptive intervention. In fractions that would have required intervention, the most appropriate plan was chosen from the patient's 'library,' and the resulting target coverage was reassessed with repeat cone-beam computed tomography. Results: A large variation in patterns of bladder filling and interfraction displacement was seen. During radiotherapy, predominant translations occurred cranially (maximum 2.5 cm) and anteriorly (maximum 1.75 cm). No apparent explanation was found for this variation using pretreatment patient factors. A need for adaptive planning was demonstrated by 51% of fractions, and 73% of fractions would have been delivered correctly using A-POLO. The adaptive strategy improved target coverage and was able to account for intrafraction motion also. Conclusions: Bladder volume variation will result in geographic miss in a high proportion of delivered bladder radiotherapy treatments. The A-POLO strategy can be used to correct for this and can be implemented from the first fraction of radiotherapy; thus, it is particularly suited to hypofractionated bladder radiotherapy regimens.

  1. Study of the possibility to use dp-elastic scattering for the Nuclotron external deuteron beam polarimetry

    International Nuclear Information System (INIS)

    Gurchin, Yu.V.; Isupov, A.Yu.; Khrenov, A.N.; Kiselev, A.S.; Ladygin, V.P.; Reznikov, S.G.; Vasil'ev, T.A.; Janek, M.; Karachuk, J.T.

    2011-01-01

    A selection of dp-elastic scattering events at energies of 1.6 and 2.0 GeV by using scintillation counters has been performed. The procedure of the CH 2 -C subtraction has been established. The dependence of the elastic events yield on the filter thickness has been investigated. This method can be used to develop the efficient high-energy deuteron beam polarimetry

  2. Preoperative infusional chemoradiation therapy for stage T3 rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rich, T.A.; Skibber, J.M.; Ajani, J.A. [Univ. of Texas M. D. Anderson Cancer Center, Houston, TX (United States)] [and others

    1995-07-15

    To evaluate preoperative infusional chemoradiation for patients with operable rectal cancer. Preoperative chemoradiation therapy using infusional 5-fluorouracil (5-FU), (300 mg/m{sup 2}/day) together with daily irradiation (45 Gy/25 fractions/5 weeks) was administered to 77 patients with clinically Stage T3 rectal cancer. Endoscopic ultrasound confirmed the digital rectal exam in 63 patients. Surgery was performed approximately 6 weeks after the completion of chemoradiation therapy and included 25 abdominoperineal resections and 52 anal-sphincter-preserving procedures. Posttreatment tumor stages were T1-2, N0 in 35%, T3, N0 in 25%, and T1-3, N1 in 11%; 29% had no evidence of tumor. Local tumor control after chemoradiation was seen in 96% (74 out of 77); 2 patients had recurrent disease at the anastomosis site and were treated successfully with abdominoperineal resection. Overall, pelvic control was obtained in 99% (76 out of 77). The survival after chemoradiation was higher in patients without node involvement than in those having node involvement (p = n.s.). More patients with pathologic complete responses or only microscopic foci survived than did patients who had gross residual tumor (p = 0.07). The actuarial survival rate was 83% at 3 years; the median follow-up was 27 months, with a range of 3 to 68 months. Acute, perioperative, and late complications were not more numerous or more severe with chemoradiation therapy than with traditional radiation therapy (XRT) alone. Excellent treatment response allowed two-thirds of the patients to have an anal-sphincter-sparing procedure. Gross residual disease in the resected specimen indicates a poor prognosis, and therapies specifically targeting these patients may improve survival further. 22 refs., 2 figs., 3 tabs.

  3. Ultrasound elastography in patients with rectal cancer treated with chemoradiation

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Vagn-Hansen, C; Sørensen, T

    2013-01-01

    OBJECTIVE: The current literature has described several predictive markers in rectal cancer patients treated with chemoradiation, but so far none of them have been validated for clinical use. The purpose of the present study was to compare quantitative elastography based on ultrasound measurements...... in the course of chemoradiation with tumor response based on T stage classification and the Mandard tumor regression grading (TRG). MATERIALS AND METHODS: We prospectively examined 31 patients with rectal cancer planned for high dose radiochemotherapy. The tumor and the mesorectal fat elasticity were measured...

  4. Fractionated perineal high-dose-rate temporary brachytherapy combined with external beam radiation in the treatment of localized prostate cancer: is lymph node sampling necessary?

    International Nuclear Information System (INIS)

    Gyorgy, Kovacs; Razvan, Galalae

    2003-01-01

    To study the influence of imaging based nodal staging and local dose escalation by a high-dose-rate brachytherapy (HDR-BT) boost in the treatment of locally confined prostate cancer in terms of prostate specific antigen (PSA) recurrence-free survival (biochemical non-evidence of disease (bNED)), treatment toxicity and prognostic variables. The prospectively recorded files of 144 men aged in a median of 68 years with a mean follow-up of 8 years (60-171 months) receiving curatively intended, transrectal ultrasound guided high-dose-rate 192-iridium-brachytherapy (HDR-BT) combined with external beam radiation therapy (EBRT) for locally confined prostate cancer were analyzed. T-stages were defined by digital rectal investigation and transrectal sonography (TRUS), nodal staging was performed with computed tomography (CT)/magnetic resonance imaging (MRI) (UICC/AJCR 1992). Twenty-nine patients (20.1%) had T1b-T2a tumors, and 115 patients had T2b-T3 tumors. Median initial PSA (iPSA) was 12.15 ng mL -1 (mean 25.61 ng mL -1 ). The total planned dose applied by external beam radiation was 50 Gy in the pelvis, and 40 Gy in the prostate by in-field-dose modification by individual compensators. The perineal, TRUS guided HDR-BT was delivered in two fractions of 15 Gy each. The target of BT boost was the peripheral zone of the prostate. The overall survival was 71.5%o and that of the disease free survival 82.6%. Freedom from distant metastases in T3 stage was 91.3%, whereas for G3 lesions, it was 88.23%. The bNED rate was 72.9%. Regarding treatment related late toxicity according to the EORTC/RTOG score, we observed grade 1, 2, 3 proctitis in 9.72%, 6.94%, 4.10% as well as grade 1, 2, 3 cystitis in 12.5%, 4.16%2.08%, respectively. Grade 4 and 5 proctitis or cystitis were not registered. The minimum 5-year and mean 8-year results confirm that local dose escalation by TRUS guided perineal HDR-BT and complementary external beam radiation of the pelvic lymphatics has curative potential

  5. High-dose-rate iridium-192 afterloading therapy combined with external beam radiotherapy for T1c-T3bN0M0 prostate cancer.

    Science.gov (United States)

    Jo, Yoshimasa; Hiratsuka, Junichi; Fujii, Tomohiro; Takenaka, Atsushi; Fujisawa, Masato

    2004-09-01

    To determine the efficacy of radiotherapy (RT) for T1c-T3bN0M0 prostate cancer in a prospective clinical trial of concurrent external beam RT and fractionated iridium-192 high-dose-rate brachytherapy. Included in the study were 98 patients with T1c-T3bN0M0 prostate cancer who were diagnosed between October 1997 and September 2002 and underwent high-dose-rate brachytherapy with external beam RT. Treatment consisted of external beam RT (four ports) to the prostate of 16 fractions of 2.3 Gy to a total dose of 36.8 Gy and high-dose-rate brachytherapy of 4 fractions of 6.0 Gy within 30 hours to a total dose of 24.0 Gy. No patient received adjuvant hormonal therapy after RT. The most recent prostate-specific antigen level was 0.0 to 3.9 ng/mL (median 0.4). Seven patients (7.1%) developed recurrence and treatment was considered a failure (bone metastasis in two and biochemical failure in five). The overall biochemical disease-free survival (bDFS) rate was 95.9% at 2 years and 92.9% at 5 years. The bDFS rate by T stage was 98.6% at 2 years and 95.9% at 5 years for Stage T1c-T2b and 88.0% and 84.0% for Stage T3a-b, respectively (P = 0.047). The 2-year and 5-year bDFS rate was better in patients with an initial prostate-specific antigen level of less than 20 ng/mL compared with 20 ng/mL or greater (98.6% and 97.1% versus 93.1% and 82.8%, respectively, P = 0.0261). Acute toxicity was mild to moderate (Radiation Therapy Oncology Group grade 1-2) and consisted of cystourethritis or proctitis in 29 (29.6%) of 98 patients. With a low complication rate and satisfactory bDFS rates, this combination therapy can be considered an alternative method for clinical Stage T1c-T3b prostate cancer and is expected to improve patient quality of life. Additional long-term follow-up is needed to confirm this treatment.

  6. Preoperative oxaliplatin, capecitabine, and external beam radiotherapy in patients with newly diagnosed, primary operable, cT3NxMo, low rectal cancer. A phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Oefner, Dietmar [Paracelsus Private Medical Univ., Salzburg (Austria). Dept. of Surgery; Innsbruck Medical Univ. (Austria). Dept. of Visceral, Transplant and Thoracic Surgery; DeVries, Alexander F. [Feldkirch Hospital (Austria). Dept. of Radio-Oncology; Schaberl-Moser, Renate [Medical Univ. Graz (AT). Div. of Oncology] (and others)

    2011-02-15

    Purpose: In patients with locally advanced rectal cancer (LARC), preoperative chemoradiation is known to improve local control, and down-staging of the tumor serves as a surrogate for survival. Intensification of the systemic therapy may lead to higher downstaging rates and, thus, enhance survival. This phase II study investigated the efficacy and safety of preoperative capecitabine and oxaliplatin in combination with radiotherapy. Patients and Methods: Patients with LARC of the mid and lower rectum, T3NxM0 staged by MRI received radiotherapy (total dose 45 Gy) in combination with oral capecitabine (825 mg/m{sup 2} twice a day on radiotherapy days; weeks 1-4) and oxaliplatin 50 mg/m{sup 2} intravenously (days 1, 8, 15, and 22). Efficacy was evaluated as rate of tumor down-categorization at the T level. Results: A total of 59 patients were enrolled (19 women, 40 men; median age of 61 years) and all were evaluable for efficacy and toxicity. Down-categorization at the T level was observed in 53% with pathological complete response in 6 patients (10%). Actual total radiotherapy, oxaliplatin and capecitabine doses received were 97%, 90%, and 93% of the protocol-specified preplanned doses, respectively. Grade 3/4 toxicity was observed in 15 patients (25%). The most frequent was diarrhea (12%). Conclusions: Preoperative chemoradiation with capecitabine and oxaliplatin is feasible in patients with MRI-proven cT3 LARC. The only clinically relevant toxicity was diarrhea. Overall, efficacy of the multimodality treatment was good, but not markedly exceeding that of 5-FU- or capecitabine-based chemoradiation approaches. (orig.)

  7. Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapy

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; Smathers, James; Deye, James

    2003-01-01

    Due to the significant interest in Monte Carlo dose calculations for external beam megavoltage radiation therapy from both the research and commercial communities, a workshop was held in October 2001 to assess the status of this computational method with regard to use for clinical treatment planning. The Radiation Research Program of the National Cancer Institute, in conjunction with the Nuclear Data and Analysis Group at the Oak Ridge National Laboratory, gathered a group of experts in clinical radiation therapy treatment planning and Monte Carlo dose calculations, and examined issues involved in clinical implementation of Monte Carlo dose calculation methods in clinical radiotherapy. The workshop examined the current status of Monte Carlo algorithms, the rationale for using Monte Carlo, algorithmic concerns, clinical issues, and verification methodologies. Based on these discussions, the workshop developed recommendations for future NCI-funded research and development efforts. This paper briefly summarizes the issues presented at the workshop and the recommendations developed by the group

  8. 20-year long-term results of the use of external beam radiotherapy for primary advanced, recurrent and metastatic malignant melanoma

    International Nuclear Information System (INIS)

    Seegenschmiedt, M. Heinrich; Keilholz, Ludwig; Altendorf-Hofmann, Annelore; Schell, Hermann; Wittekind, Christian; Sauer, Rolf

    1997-01-01

    Purpose: The use of external beam radiotherapy (RT) is regarded only as 'last resort' approach in the multidisciplinary management of malignant melanoma (MM). We have analyzed the initial tumor response and the long-term local control, survival rate and relevant prognostic factors in patients with locally advanced, recurrent and metastatic MM who have been treated at our institution over the past 20 years. Methods: Between 1977 - 1995, a total of 2917 consecutive patients have been entered in the malignant melanoma registry of our university hospital. Just 121 (4%) out of these 2917 (4%) consecutive patients, i.e. 56 females and 65 males with histologically proven and clinically staged malignant melanoma (MM), have been selected during their disease process to receive external beam RT due to their advanced stage of the disease. The primary histology was nodular melanoma (NM) in 51 (47%) pts., superficial spreading melanoma (SSM) in 35 (32%) pts.; acral-lentiginous melanoma (ALM) in 8 (7%) pts. and lentigo maligna melanoma (LMM) in 4 (5%) pts.. The specific clinical indication for the application of RT was primarily for palliative reasons in the advanced clinical UICC stages II and IV: (a) 11 (9%) pts had residual disease (R1-2) after resection of a primary or recurrent MM (UICC II); (b) 57 (47%) pts suffered from regional lymph node metastases (33 pts.) or in-transit metastases (24 pts.) (UICC III); and (c) 53 (44%) pts had distant metastases at various body sites (7 pts. with M1a; 46 pts. with M1b) (UICC IV). The mean interval between the first diagnosis and actual application of the external beam radiotherapy (RT) was 19 months (range: 3 - 186 months). In most cases conventional RT and only in a few cases hypofractionated RT was applied with 2 - 6 Gy single dose fractions up to a median total RT dose of 48 Gy (range: 20 - 60 Gy). Results: The median follow-up of the patients (FU) was 9 years (range: 0.3 - 15.5 yrs.). With regard to UICC stages, an initial

  9. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Use of External Beam Radiotherapy Is Associated With Reduced Incidence of Second Primary Head and Neck Cancer: A SEER Database Analysis

    International Nuclear Information System (INIS)

    Rusthoven, Kyle; Chen Changhu; Raben, David; Kavanagh, Brian

    2008-01-01

    Purpose: Patients with head and neck cancer have a significant risk of developing a second primary cancer of the head and neck. We hypothesized that treatment with external beam radiotherapy (RT) might reduce this risk, because RT can eradicate occult foci of second head and neck cancer (HNCA). Methods and Materials: The data of patients with Surveillance, Epidemiology, and End Results Historic Stage A localized squamous cell carcinoma of the oral cavity, larynx, and pharynx were queried using the Surveillance, Epidemiology, and End Results database. For patients treated with or without RT, the incidence of second HNCA was determined and compared using the log-rank method. Cox proportional hazards analysis was performed for each site, evaluating the influence of covariates on the risk of second HNCA. Results: Between 1973 and 1997, 27,985 patients were entered with localized HNCA. Of these patients, 44% had received RT and 56% had not. The 15-year incidence of second HNCA was 7.7% with RT vs. 10.5% without RT (hazard ratio 0.71, p <0.0001). The effect of RT was more profound in patients diagnosed between 1988 and 1997 (hazard ratio 0.53, p <0.0001) and those with pharynx primaries (hazard ratio 0.47, p <0.0001). On multivariate analysis, RT was associated with a reduced risk of second HNCA for pharynx (p <0.0001) and larynx (p = 0.04) tumors. For oral cavity primaries, RT was associated with an increased risk of second HNCA in patients treated before 1988 (p <0.001), but had no influence on patients treated between 1988 and 1997 (p = 0.91). Conclusion: For localized HNCA, RT is associated with a reduced incidence of second HNCA. These observations are consistent with the eradication of microscopic foci of second HNCA with external beam RT

  11. Can We Predict Plan Quality for External Beam Partial Breast Irradiation: Results of a Multicenter Feasibility Study (Trans Tasman Radiation Oncology Group Study 06.02)

    Energy Technology Data Exchange (ETDEWEB)

    Kron, Tomas, E-mail: Tomas.Kron@petermac.org [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia); School of Science, Engineering and Technology, Royal Melbourne Institute of Technology University, Melbourne, Victoria (Australia); Willis, David; Link, Emma [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Lehman, Margot [Princess Alexandra Hospital, Department of Radiation Oncology, Brisbane, Queensland (Australia); Campbell, Gillian [Auckland City Hospital, Department of Radiation Oncology, Auckland (New Zealand); O' Brien, Peter [Newcastle Calvary Mater Hospital, Department of Radiation Oncology, Newcastle, NSW (Australia); Chua, Boon [Peter MacCallum Cancer Centre, Departments of Radiation Oncology, Physical Sciences and Radiation Therapy, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia)

    2013-11-15

    Purpose: Partial breast irradiation (PBI) after lumpectomy may be an option for selected patients with early breast cancer. A feasibility study of accelerated PBI delivered using external beam 3-dimensional conformal radiation therapy (RT) was undertaken at 8 Australasian centers. The present study evaluated the impact of patient, tumor, and RT technique-related factors on the quality of RT plans as determined by the dose–volume parameters of organs at risk. Methods and Materials: Forty-eight patients were enrolled in the study. All RT plans were centrally reviewed using predefined dosimetric criteria before commencement and after completion of protocol therapy. The RT plans of 47 patients met the dose–volume constraints, and all 47 patients received PBI to a prescribed dose of 38.5 Gy in 10 fractions. The RT plan quality was determined by volumes of the ipsilateral whole breast, lung, and heart that received 50% and 95%; 30%; and 5% of the prescribed dose, respectively. Patient, tumor, and RT technique-related factors were investigated for association with the parameters of RT plan quality. Results: The ratio of the planning target volume to the ipsilateral whole-breast volume was significantly associated with the ipsilateral breast doses on multiple variable analyses. The distance of the postlumpectomy surgical cavity from the heart and lung were predictive for heart and lung doses, respectively. A distance between surgical cavity and heart of >4 cm typically resulted in <1% of the heart volume receiving 5 Gy or less. It was more difficult to meet the heart dose constraint for left-sided and medially located tumors. Conclusions: Partial breast irradiation using 3-dimensional conformal RT was feasible within the study constraints. The ratio of planning target volume to ipsilateral whole-breast volume and the distance of surgical cavity from the heart were significant predictors of the quality of treatment plan for external beam PBI.

  12. External Beam Accelerated Partial-Breast Irradiation Using 32 Gy in 8 Twice-Daily Fractions: 5-Year Results of a Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Pashtan, Itai M. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Ancukiewicz, Marek [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Brachtel, Elena [Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts (United States); Abi-Raad, Rita F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); D' Alessandro, Helen A. [Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts (United States); Levy, Antonin; Wo, Jennifer Y. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Hirsch, Ariel E. [Department of Radiation Oncology, Boston Medical Center, Boston University School of Medicine, Boston, Massachusetts (United States); Kachnic, Lisa A. [Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Goldberg, Saveli [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Specht, Michelle; Gadd, Michelle; Smith, Barbara L. [Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Powell, Simon N. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Taghian, Alphonse G., E-mail: ataghian@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2012-11-01

    Purpose: External beam accelerated partial breast irradiation (APBI) is an increasingly popular technique for treatment of patients with early stage breast cancer following breast-conserving surgery. Here we present 5-year results of a prospective trial. Methods and Materials: From October 2003 through November 2005, 98 evaluable patients with stage I breast cancer were enrolled in the first dose step (32 Gy delivered in 8 twice-daily fractions) of a prospective, multi-institutional, dose escalation clinical trial of 3-dimensional conformal external beam APBI (3D-APBI). Median age was 61 years; median tumor size was 0.8 cm; 89% of tumors were estrogen receptor positive; 10% had a triple-negative phenotype; and 1% had a HER-2-positive subtype. Median follow-up was 71 months (range, 2-88 months; interquartile range, 64-75 months). Results: Five patients developed ipsilateral breast tumor recurrence (IBTR), for a 5-year actuarial IBTR rate of 5% (95% confidence interval [CI], 1%-10%). Three of these cases occurred in patients with triple-negative disease and 2 in non-triple-negative patients, for 5-year actuarial IBTR rates of 33% (95% CI, 0%-57%) and 2% (95% CI, 0%-6%; P<.0001), respectively. On multivariable analysis, triple-negative phenotype was the only predictor of IBTR, with borderline statistical significance after adjusting for tumor grade (P=.0537). Conclusions: Overall outcomes were excellent, particularly for patients with estrogen receptor-positive disease. Patients in this study with triple-negative breast cancer had a significantly higher IBTR rate than patients with other receptor phenotypes when treated with 3D-APBI. Larger, prospective 3D-APBI clinical trials should continue to evaluate the effect of hormone receptor phenotype on IBTR rates.

  13. Retinoblastoma external beam photon irradiation with a special ‘D’-shaped collimator: a comparison between measurements, Monte Carlo simulation and a treatment planning system calculation

    Science.gov (United States)

    Brualla, L.; Mayorga, P. A.; Flühs, A.; Lallena, A. M.; Sempau, J.; Sauerwein, W.

    2012-11-01

    Retinoblastoma is the most common eye tumour in childhood. According to the available long-term data, the best outcome regarding tumour control and visual function has been reached by external beam radiotherapy. The benefits of the treatment are, however, jeopardized by a high incidence of radiation-induced secondary malignancies and the fact that irradiated bones grow asymmetrically. In order to better exploit the advantages of external beam radiotherapy, it is necessary to improve current techniques by reducing the irradiated volume and minimizing the dose to the facial bones. To this end, dose measurements and simulated data in a water phantom are essential. A Varian Clinac 2100 C/D operating at 6 MV is used in conjunction with a dedicated collimator for the retinoblastoma treatment. This collimator conforms a ‘D’-shaped off-axis field whose irradiated area can be either 5.2 or 3.1 cm2. Depth dose distributions and lateral profiles were experimentally measured. Experimental results were compared with Monte Carlo simulations’ run with the penelope code and with calculations performed with the analytical anisotropic algorithm implemented in the Eclipse treatment planning system using the gamma test. penelope simulations agree reasonably well with the experimental data with discrepancies in the dose profiles less than 3 mm of distance to agreement and 3% of dose. Discrepancies between the results found with the analytical anisotropic algorithm and the experimental data reach 3 mm and 6%. Although the discrepancies between the results obtained with the analytical anisotropic algorithm and the experimental data are notable, it is possible to consider this algorithm for routine treatment planning of retinoblastoma patients, provided the limitations of the algorithm are known and taken into account by the medical physicist and the clinician. Monte Carlo simulation is essential for knowing these limitations. Monte Carlo simulation is required for optimizing the

  14. Pretreatment Endorectal Coil Magnetic Resonance Imaging Findings Predict Biochemical Tumor Control in Prostate Cancer Patients Treated With Combination Brachytherapy and External-Beam Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Riaz, Nadeem [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Afaq, Asim; Akin, Oguz [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Pei Xin; Kollmeier, Marisa A.; Cox, Brett [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Hricak, Hedvig [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2012-11-01

    Purpose: To investigate the utility of endorectal coil magenetic resonance imaging (eMRI) in predicting biochemical relapse in prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Methods and Materials: Between 2000 and 2008, 279 men with intermediate- or high-risk prostate cancer underwent eMRI of their prostate before receiving brachytherapy and supplemental intensity-modulated radiotherapy. Endorectal coil MRI was performed before treatment and retrospectively reviewed by two radiologists experienced in genitourinary MRI. Image-based variables, including tumor diameter, location, number of sextants involved, and the presence of extracapsular extension (ECE), were incorporated with other established clinical variables to predict biochemical control outcomes. The median follow-up was 49 months (range, 1-13 years). Results: The 5-year biochemical relapse-free survival for the cohort was 92%. Clinical findings predicting recurrence on univariate analysis included Gleason score (hazard ratio [HR] 3.6, p = 0.001), PSA (HR 1.04, p = 0.005), and National Comprehensive Cancer Network risk group (HR 4.1, p = 0.002). Clinical T stage and the use of androgen deprivation therapy were not correlated with biochemical failure. Imaging findings on univariate analysis associated with relapse included ECE on MRI (HR 3.79, p = 0.003), tumor size (HR 2.58, p = 0.04), and T stage (HR 1.71, p = 0.004). On multivariate analysis incorporating both clinical and imaging findings, only ECE on MRI and Gleason score were independent predictors of recurrence. Conclusions: Pretreatment eMRI findings predict for biochemical recurrence in intermediate- and high-risk prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Gleason score and the presence of ECE on MRI were the only significant predictors of biochemical relapse in this group of patients.

  15. Second malignancies following conventional or combined ²⁵²Cf neutron brachytherapy with external beam radiotherapy for breast cancer.

    Science.gov (United States)

    Valuckas, Konstantinas Povilas; Atkocius, Vydmantas; Kuzmickiene, Irena; Aleknavicius, Eduardas; Liukpetryte, Sarune; Ostapenko, Valerijus

    2013-09-01

    We retrospectively evaluated the risk of second malignancies among 832 patients with inner or central breast cancer treated with conventional external beam schedule (CRT group), or neutron brachytherapy using Californium-252 (²⁵²Cf) sources and hypofractionated external beam radiotherapy (HRTC group), between 1987 and 1996 at the Institute of Oncology, Vilnius University. Patients were observed until the occurrences of death or development of a second malignancy, or until 31 December 2009, whichever was earlier. Median follow-up time was 10.4 years (range, 1.2-24.1 years). Risk of second primary cancers was quantified using standardized incidence ratios (SIRs). Cox proportional hazards regression models were used to estimate hazard ratios (HRs). There was a significant increase in the risk of second primary cancers compared with the general population (SIR 1.3, 95% CI 1.1-1.5). The observed number of second primary cancers was also higher than expected for breast (SIR 1.8, 95% CI 1.3-2.4) and lung cancer (SIR 3.8, 95% CI 2.0-6.7). For second breast cancer, no raised relative risk was observed during the period ≥10 or more years after radiotherapy. Compared with the CRT group, HRTC patients had a not statistically significant higher risk of breast cancer. Increased relative risks were observed specifically for age at initial diagnosis of <50 years (HR 2.9, 95% CI 1.6-5.2) and for obesity (HR 2.8, 95% CI 1.1-7.2).

  16. Corrosion of 15th and early 16th century stained glass from the monastery of Batalha studied with external ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Vilarigues, M., E-mail: mgv@fct.unl.pt [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Redol, P. [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Monastery of Batalha, P-2440 (Portugal); Machado, A. [Dep. de Conservacao e Restauro and Centro do Vidro e da Ceramica para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Rodrigues, P.A.; Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2011-02-15

    This paper reports the study of corrosion in two stained glass panels from the south aisle of Sta. Maria da Vitoria monastery, at Batalha (Portugal), one depicting the Last Supper (dated from 1508), and the other one showing a saint (c. 1450). These panels exhibit extensive corrosion with darkening phenomena that are an impediment to their correct visualization, a source of major concern both to conservators and curators. By using external micro-beam Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma Emission (PIGE) spectrometry, the elemental compositions of large fragments were obtained, enabling the selection of representative corroded areas, from which elemental distribution maps were produced by scanning. Calcium and potassium rich structures were found - at the surface and inside cavities in the glass - that were identified as oxalates and carbonates, by Raman microscopy and micro-FTIR. The dark spots present in the glass surfaces were found to be Zn and Pb rich. These findings indicate that the corrosion observed was due not only to reactions with atmospheric water and CO{sub 2} but also with the oxalic acid secreted by micro-organisms. Furthermore, it did not result from reactions with atmospheric SO{sub 2} or acid rain. The information obtained is relevant for a better understanding of the corrosion processes and products formed on the surface of these panels and therefore for the proper planning of much needed adequate conservation-restoration actions and appropriate display conditions. - Research Highlights: {yields} Corrosion and darkening of stained glasses is of concern to conservators and curators. {yields} A multi-technique approach is of relevance to study stained glass corrosion. {yields} External beam PIXE-PIGE provide valuable insight on stained glass corrosion.

  17. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    International Nuclear Information System (INIS)

    Feygelman, V; Nelms, B

    2013-01-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of ''quality'' as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  18. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    Science.gov (United States)

    Feygelman, V.; Nelms, B.

    2013-06-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of "quality" as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  19. Dosimetric characterization of VIPARnd gel by optical analysis to high-energy photon beam used in external radiotherapy

    International Nuclear Information System (INIS)

    Dias, Juliana R.; Lima, Renata S.; Lopes, Roseany de V. Vieira; Ceschin, Artemis Marti

    2015-01-01

    Polymer gel dosimetry has been proposed as a possibility for measurements of dose distribution in radiotherapy. This work aims to evaluate the dosimetric characteristics of a VIPARnd for 6 MV photon beam used in radiotherapy using optical investigations. The absorbance spectrum of irradiated gel dosimeter was optical evaluated with spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose-response curve for blue component showed interval of linearity from 1 Gy to 20 Gy. (author)

  20. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    Science.gov (United States)

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  1. Normal tissue tolerance to external beam radiation therapy: Small bowel; Dose de tolerance a l'irradiation des tissus sains: intestin grele

    Energy Technology Data Exchange (ETDEWEB)

    Martin, E. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 21 - Dijon (France); Pointreau, Y.; Barillot, I. [Service de radiotherapie, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau, CHRU de Tours, 37 - Tours (France); Roche-Forestier, S. [Centre Jean-Bernard, 72 - Le Mans (France); Barillot, I. [Universite Francois-Rabelais, centre de cancerologie Henry-S.-Kaplan, CHU de Tours, 37 - Tours (France)

    2010-07-15

    The small bowel is a hollow organ involved in the transit and absorption of food. In relation to its anatomical location, a significant amount of this organ is exposed in whole or in part to ionizing radiation in external radiotherapy during abdominal or pelvic irradiation either for primary cancers or metastasis. The acute functional changes during external beam radiation are mainly leading to diarrhea, abdominal pain and bloating. The main late side effects of irradiation of the small intestine are chronic diarrhea, malabsorption with steatorrhoea, abdominal spasms, intestinal obstruction, bleeding and fistulas. The architecture of the small intestine may be considered as parallel with a significant correlation between the irradiated volume of small bowel and the likelihood of acute toxicity, whatever the dose. The literature analysis recommends to consider the volume of small bowel receiving 15 Gy (threshold of 100 to 200 cm{sup 3}) but also 30 and 50 Gy (thresholds of 35 to 300 cm{sup 3}, depending on the level of dose considered). Modern techniques of conformal radiotherapy with modulated intensity will probably have beneficial impact on small bowel toxicity. (authors)

  2. External beam radiation therapy for recurrent sigmoid colorectal cancer. Retrospective analysis by group comparison between the radiation therapy alone and the radiation therapy combined with other therapies

    International Nuclear Information System (INIS)

    Churei, Hisahiko; Takeshita, Tsuyoshi; Hiraki, Yoshiyuki; Baba, Yasutaka; Hokotate, Hirohumi; Nakajo, Masayuki; Ohkubo, Kouichi; Miyaji, Noriaki

    1999-01-01

    The purpose of this study is to evaluate retrospectively clinical efficacy of curativeintent external beam radiation therapy for recurrent sigmoid colorectal cancer. As the radiation therapy of higher dose level combined with other therapies might improve pain control, tumor response, and prognosis, the total dose over 60 Gy was delivered except cases that were received surgery for the recurrent tumor. The study population consisted of 25 patients received the radiation therapy alone (RTA) and 24 patients received the radiation therapy combined with other one or two treatment modalities (RTC), which included surgery (tumor resection) in 15 cases, chemotherapy (low dose daily CDDP) in 13 cases, and hyperthermia in 6 cases. They received the radiation therapy from January, 1989 to June, 1996. Data on pain relief and tumor response were compared between the groups of RTA and RTC. The effect on pain relief was not different between the two groups. Tumor response appeared to be high in the patients combined with chemotherapy, but the difference was not statistically significant between the groups. There were no differences in the prognosis by the recurrent tumor size, the pain relief, and the tumor response. There was a statistically significant difference in the prognosis between the groups with and without extrapelvic distant metastases. A more effective treatment modality combined with the external radiation therapy is necessary to improve the clinical efficacy for the recurrent sigmoid colorectal cancer. (author)

  3. Pre-treatment MRI minimum apparent diffusion coefficient value is a potential prognostic imaging biomarker in cervical cancer patients treated with definitive chemoradiation

    International Nuclear Information System (INIS)

    Marconi, Daniel Grossi; Fregnani, Jose Humberto Tavares Guerreiro; Rossini, Rodrigo Ribeiro; Netto, Ana Karina Borges Junqueira; Lucchesi, Fabiano Rubião; Tsunoda, Audrey Tieko; Kamrava, Mitchell

    2016-01-01

    Diffusion Weighted (DW) Magnetic Resonance Imaging (MRI) has been studed in several cancers including cervical cancer. This study was designed to investigate the association of DW-MRI parameters with baseline clinical features and clinical outcomes (local regional control (LRC), disease free survival (DFS) and disease specific survival (DSS)) in cervical cancer patients treated with definitive chemoradiation. This was a retrospective study approved by an institutional review board that included 66 women with cervical cancer treated with definitive chemoradiation who underwent pre-treatment MRI at our institution between 2012 and 2013. A region of interest (ROI) was manually drawn by one of three radiologists with experience in pelvic imaging on a single axial CT slice encompassing the widest diameter of the cervical tumor while excluding areas of necrosis. The following apparent diffusion coefficient (ADC) values (×10 −3 mm 2 /s) were extracted for each ROI: Minimum - ADC min , Maximum - ADC max , Mean - ADC mean , and Standard Deviation of the ADC - ADC dev . Receiver operating characteristic (ROC) curves were built to choose the most accurate cut off value for each ADC value. Correlation between imaging metrics and baseline clinical features were evaluated using the Mann Whitney test. Confirmatory multi-variate Cox modeling was used to test associations with LRC (adjusted by gross tumor volume – GTV), DFS and DSS (both adjusted by FIGO stage). Kaplan Meyer curves were built for DFS and DSS. A p-value < 0.05 was considered significant. Women median age was 52 years (range 23–90). 67 % had FIGO stage I-II disease while 33 % had FIGO stage III-IV disease. Eighty-two percent had squamous cell cancer. Eighty-eight percent received concurrent cisplatin chemotherapy with radiation. Median EQD2 of external beam and brachytherapy was 82.2 Gy (range 74–84). Women with disease staged III-IV (FIGO) had significantly higher mean ADC max values compared with those

  4. Postprostatectomy ultrasound-guided transrectal implantation of gold markers for external beam radiotherapy. Technique and complications rate

    Energy Technology Data Exchange (ETDEWEB)

    Langenhuijsen, J.F.; Kiemeney, L.A.L.M.; Witjes, J.A. [Radboud Univ. Nijmegen Medical Center, Nijmegen (Netherlands). Dept. of Urology; Donker, R. [Medical Center Alkmaar (Netherlands). Dept. of Radiation Oncology; McColl, G.M.; Lin, E.N.J.T. van [Radboud Univ. Nijmegen Medical Center, Nijmegen (Netherlands). Dept. of Radiation Oncology

    2013-06-15

    Background and purpose: Postprostatectomy radiotherapy (RT) improves survival in adjuvant and salvage settings. The implantation technique and complications rate of gold markers in the prostate bed for high-precision RT were analyzed. Patients and methods: Patients undergoing postprostatectomy RT for prostate-specific antigen (PSA) relapse or high-risk disease were enrolled in the study. Under transrectal ultrasound guidance, three fine gold markers were implanted in the prostate bed and the technical difficulties of insertion were documented. Patients received our self-designed questionnaires concerning complications and pain. The influence of anticoagulants and coumarins on bleeding was analyzed, as was the effect of potential risk factors on pain. Results: In 77 consecutive patients, failure of marker implantation or marker migration was seen in six cases. Rectal bleeding was reported by 10 patients and 1 had voiding complaints. No macroscopic hematuria persisting for more than 3 days was observed. Other complications included rectal discomfort (n = 2), nausea (n = 1), abdominal discomfort (n = 1), and pain requiring analgesics (n = 4). No major complications were reported. On a 0-10 visual analogue scale (VAS), the mean pain score was 3.7. No clinically significant risk factors for complications were identified. Conclusion: Transrectal implantation of gold markers in the prostate bed is feasible and safe. Alternatives like cone beam computed tomography (CBCT) should be considered, but the advantages of gold marker implantation for high-precision postprostatectomy RT would seem to outweigh the minor risks involved. (orig.)

  5. Initial dosimetric experience using simple three-dimensional conformal external-beam accelerated partial-breast irradiation

    International Nuclear Information System (INIS)

    Taghian, Alphonse G.; Kozak, Kevin R.; Doppke, Karen P.; Katz, Angela; Smith, Barbara L.; Gadd, Michele; Specht, Michelle; Hughes, Kevin; Braaten, Kristina; Kachnic, Lisa A.; Recht, Abram; Powell, Simon N.

    2006-01-01

    Purpose: Several accelerated partial-breast irradiation (APBI) techniques are being investigated in patients with early-stage breast cancer. We present our initial experience using three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Sixty-one patients with tumors of 2 cm or less and negative axillary nodes were treated with 3D-CRT accelerated partial-breast irradiation (APBI) between August 2003 and March 2005. The prescribed radiation dose was 32 Gy in 4-Gy fractions given twice daily. Efforts were made to minimize the number of beams required to achieve adequate planning target volume (PTV) coverage. Results: A combination of photons and electrons was used in 85% of patients. A three-field technique that consisted of opposed, conformal tangential photons and enface electrons was employed in 43 patients (70%). Nine patients (15%) were treated with a four-field arrangement, which consisted of three photon fields and enface electrons. Mean PTV volumes that received 100%, 95%, and 90% of the prescribed dose were 93% ± 7%, 97% ± 4%, and 98% ± 2%, respectively. Dose inhomogeneity exceeded 10% in only 7 patients (11%). Mean doses to the ipsilateral lung and heart were 1.8 Gy and 0.8 Gy, respectively. Conclusions: Simple 3D-CRT techniques of APBI can achieve appropriate PTV coverage while offering significant normal-tissue sparing. Therefore, this noninvasive approach may increase the availability of APBI to patients with early-stage breast cancer

  6. Digital test objects (D.T.O.) for treatment planning systems quality control in external beam radiotherapy

    International Nuclear Information System (INIS)

    Denis, E.

    2008-04-01

    This work presents the conception and implementation of new automatic and quantitative quality assessment methods for geometric treatment planning in external radiotherapy. Treatment planning Systems (T.P.S.) quality control is mandatory in France and in the world because of encountered risks but the physical tools recommended to lead this quality control are not adapted to the situation. We present a new methodology for control quality based on the definition of Digital Test Objects (D.T.O.) that are directly introduced in the T.P.S. without acquisition device. These D.T.O. are consistently defined in a continuous and discrete modes. The T.P.S. responses to input D.T.O. are compared to theoretical results thanks to figures of merit specifically designed for each elementary control. The tests we carried out during this study allow to validate our solutions for the quality assessment of the auto-contouring, auto-margining, isocenter computation, collimator conformation and digitally reconstructed radiograph generation tools, as well as our solutions for marker positioning, collimator and displayed bean rotation, incidence, divergence and dimensions. Quality assessment solutions we propose are then fast and effective (no acquisition by the device, reduced manipulations), and more precise thanks to the continuous-discrete equivalence realized at the beginning of the modelling

  7. Limb-sparing management with surgical resection, external-beam and intraoperative electron-beam radiation therapy boost for patients with primary soft tissue sarcoma of the extremity. A multicentric pooled analysis of long-term outcomes

    International Nuclear Information System (INIS)

    Calvo, Felipe A.; Sole, Claudio V.; Polo, Alfredo; Montero, Angel; Cambeiro, Mauricio; Martinez-Monge, Rafael; Alvarez, Ana; Cuervo, Miguel; Julian, Mikel San

    2014-01-01

    A joint analysis of data from three contributing centres within the intraoperative electron-beam radiation therapy (IOERT) Spanish program was performed to investigate the main contributions of IORT to the multidisciplinary treatment of high-risk extremity soft tissue sarcoma (STS). Patients with an histologic diagnosis of primary extremity STS, with absence of distant metastases, undergoing limb-sparing surgery with radical intent, external beam radiotherapy (median dose 45 Gy) and IOERT (median dose 12.5 Gy) were considered eligible for participation in this study. From 1986-2012, a total of 159 patients were analysed in the study from three Spanish institutions. With a median follow-up time of 53 months (range 4-316 years), 5-year local control (LC) was 82 %. The 5-year IOERT in-field control, disease-free survival (DFS) and overall survival (OS) were 86, 62 and 72 %, respectively. On multivariate analysis, only microscopically involved margin (R1) resection status retained significance in relation to LC (HR 5.20, p [de

  8. SU-E-T-273: Do Task Group External Beam QA Recommendations Guarantee Accurate Treatment Plan Dose Delivery?

    International Nuclear Information System (INIS)

    Templeton, A; Liao, Y; Redler, G; Zhen, H

    2015-01-01

    Purpose: AAPM task groups 40/142 have provided an invaluable set of goals for physicists designing QA programs, attempting to standardize what would otherwise likely be a highly variable phenomenon across institutions. However, with the complexity of modalities such as VMAT, we hypothesize that following these guidelines to the letter might still allow unacceptable dose discrepancies. To explore this hypothesis we simulated machines bordering on QA acceptability, and calculated the effect on patient plans. Methods: Two errant machines were simulated in Aria/Eclipse, each just within task group criteria for output, percent depth dose, beam profile, gantry and collimator rotations, and jaw and MLC positions. One machine minimized dose to the PTV (machine A) and the other maximized dose to the OARs (machine B). Clinical treatment plans (3-phase prostate, n=3; hypofractionated lung, n=1) were calculated on these machines and the dose distributions compared. A prostate case was examined for contribution of error sources and evaluated using delivery QA data. Results: The prostate plans showed mean decreases in target D95 of 9.9% of prescription dose on machine A. On machine B, The rectal and bladder V70Gy each increased by 7.1 percentage points, while their V45Gy increased by 16.2% and 15.0% respectively. In the lung plan, the target D95 decreased by 12.8% and the bronchial tree Dmax increased by 21% of prescription dose, on machines A and B. One prostate plan showed target dose errors of 3.8% from MLC changes, 2% from output, ∼3% from energy and ∼0.5% from other factors. This plan achieved an 88.4% gamma passing rate using 3%/3mm using ArcCHECK. Conclusion: In the unlikely event that a machine exhibits all maximum errors allowed by TG 40/142, unacceptably large changes in dose delivered are possible especially in highly modulated VMAT plans, despite the machine passing routine QA

  9. Adaptive radiation therapy for postprostatectomy patients using real-time electromagnetic target motion tracking during external beam radiation therapy.

    Science.gov (United States)

    Zhu, Mingyao; Bharat, Shyam; Michalski, Jeff M; Gay, Hiram A; Hou, Wei-Hsien; Parikh, Parag J

    2013-03-15

    Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (Dmin) with the planned Dmin to the CTV. Treatments were considered adequate if the delivered CTV Dmin is at least 95% of the planned CTV Dmin. Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: -0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Perspectives in absorbed dose metrology with regard to the technical evolutions of external beam radiotherapy; Perspectives en metrologie de la dose face aux evolutions techniques de la radiotherapie externe

    Energy Technology Data Exchange (ETDEWEB)

    Chauvenet, B.; Bordy, J.M. [CEA Saclay, Lab. National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France); Barthe, J. [CEA Saclay (LIST), 91 - Gif-sur-Yvette (France)

    2009-07-01

    This paper presents several R and D axes in absorbed close metrology to meet the needs resulting from the technical evolutions of external beam radiotherapy. The facilities in operation in France have considerably evolved under the impulse of the plan Cancer launched in 2003: replacements and increase of the number of accelerators, substitution of accelerators for telecobalt almost completed and acquisition of innovative facilities for tomo-therapy and stereotaxy. The increasing versatility of facilities makes possible the rapid evolution of treatment modalities, allowing to better delimit irradiation to tumoral tissues and spare surrounding healthy tissues and organs at risk. This leads to a better treatment efficacy through dose escalation. National metrology laboratories must offer responses adapted to the new need, i.e. not restrict themselves to the establishment of references under conventional conditions defined at international level, contribute to the improvement of uncertainties at all levels of reference transfer to practitioners: primary measurements under conditions as close as possible to those of treatment, characterization of transfer and treatment control dosimeters., metrological validation of treatment planning tools... Those axes have been identified as priorities for the next years in ionizing radiation metrology at the European level and included in the European. Metrology Research Programme. A project dealing with some of those topics has been selected in the frame of the Eranet+ Call EMRP 2007 and is now starting. The LNE-LAM is strongly engaged in it. (authors)

  11. A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

    Directory of Open Access Journals (Sweden)

    Payam Samadi Miandoab

    2016-12-01

    Full Text Available Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion of dynamic organs, a phantom employs non-uniform rational B-splines (NURBS-based Cardiac-Torso method with spline-based model to generate 4D computed tomography (CT images. First, to generate all the possible roto-translation positions, the 4D CT images were imported to Medical Image Data Examiner (AMIDE. Then, for automatic, real time verification of geometrical setup, an artificial neural network (ANN was proposed to estimate patient displacement, using training sets. Moreover, three external motion markers were synchronized with a patient couch position as reference points. In addition, the technique was validated through simulated activities by using reference 4D CT data acquired from five patients. Results The results indicated that patient geometrical set-up is highly depended on the comprehensiveness of training set. By using ANN model, the average patient setup error in XCAT phantom was reduced from 17.26 mm to 0.50 mm. In addition, in the five real patients, these average errors were decreased from 18.26 mm to 1.48 mm various breathing phases ranging from inhalation to exhalation were taken into account for patient setup. Uncertainty error assessment and different setup errors were obtained from each respiration phase. Conclusion This study proposed a new method for alignment of patient setup error using ANN model. Additionally, our correlation model (ANN could estimate true patient position with less error.

  12. How successful is high-dose (≥60 GY) reirradiation using mainly external beams in salvaging local failures of nasopharyngeal carcinoma?

    International Nuclear Information System (INIS)

    Teo, Peter Man Lung; Kwan, W.H.; Chan, Anthony Tak Cheung; Lee, W.Y.; King, Walter Wing Keung; Mok, C.O.

    1998-01-01

    Purpose: To evaluate the efficacy of high-dose (≥60 Gy) reirradiation using mainly external beams in salvaging local failures of nasopharyngeal carcinoma (NPC) after modern primary radical radiotherapy that delivered radical dose-to-target volumes defined by CT scan. Methods and Materials: Nine hundred and three patients with nondisseminated NPC whose primary radical radiotherapy was administered between 1984 and 1989 inclusive were studied. One hundred and seventy-six had local failures comprising 9 persistences and 167 recurrences. In 10 patients the local failures were preceded or accompanied by (within 2 months) distant metastases, and these were given supportive treatment or palliative radiotherapy in low dose (<60 Gy) if symptomatic. Most of the rest (123 of 166) were treated with either reirradiation to high dose (≥60 Gy) using mainly external photon beams (n = 103) or nasopharyngectomy with/without radical neck dissection with/without postoperative radiotherapy (n = 20). The remainder (n = 43) received only palliative treatments because of poor general condition and/or patients' refusal of radical treatments. The primary radiotherapy was planned on the basis of target volumes defined by CT scan and given to a standard nasopharyngeal dose of 62.5 Gy/29 fractions/6 weeks. In the presence of parapharyngeal involvement, an additional boost of 20 Gy/10 fractions/2 weeks was given via a posterior oblique photon beam. If local residual tumors were diagnosed at 4-6 weeks after the completion of external radiotherapy, an additional boost of 24 Gy/3 fractions/15 days was given by intracavitary intubation. For the local failures given high-dose reirradiation, the target volume was defined by CT scan and treated by a two-field or a three-field photon arrangement with or without additional dose supplement by intracavitary intubation. Nasopharyngectomy was performed via the transcervico-mandibulo-palatal approach or the maxillary swing approach. Radical neck

  13. Weight bearing cone beam CT scan versus gravity stress radiography for analysis of supination external rotation injuries of the ankle.

    Science.gov (United States)

    Marzo, John M; Kluczynski, Melissa A; Clyde, Corey; Anders, Mark J; Mutty, Christopher E; Ritter, Christopher A

    2017-12-01

    For AO 44-B2 ankle fractures of uncertain stability, the current diagnostic standard is to obtain a gravity stress radiograph, but some have advocated for the use of weight-bearing radiographs. The primary aim was to compare measures of medial clear space (MCS) on weight-bearing cone beam computed tomography (CBCT) scans versus gravity stress radiographs for determining the state of stability of ankle fractures classified as AO SER 44-B2 or Weber B. The secondary aim was to evaluate the details offered by CBCT scans with respect to other findings that may be relevant to patient care. Nine patients were enrolled in this cross-sectional study between April 2016 and February 2017 if they had an AO SER 44-B2 fracture of uncertain stability, had a gravity stress radiograph, and were able to undergo CT scan within seven days. The width of the MCS was measured at the level of the talar dome on all radiographs and at the mid coronal slice on CT. Wilcoxon signed-ranks tests were used to compare MCS between initial radiographs, gravity stress radiographs and weight-bearing CBCT scans. MCS on weight-bearing CBCT scan (1.41±0.41 mm) was significantly less than standard radiographs (3.28±1.63 mm, P=0.004) and gravity stress radiographs (5.82±1.93 mm, P=0.02). There was no statistically significant difference in MCS measured on standard radiographs versus gravity stress radiographs (P=0.11). Detailed review of the multiplanar CT images revealed less than perfect anatomical reduction of the fractures, with residual fibular shortening, posterior displacement, and fracture fragments in the incisura as typical findings. Similar to weight-bearing radiographs, weight-bearing CBCT scan can predict stability of AO 44-B2 ankle fractures by showing restoration of the MCS, and might be used to indicate patients for non-operative treatment. None of the fractures imaged in this study were perfectly reduced however, and further clinical research is necessary to determine if any of the

  14. Comparison of quality of life in patients with nasopharyngeal carcinoma receiving conventional external beam radiation therapy versus intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zheng Lu; Yan Senxiang; Yan Danfang

    2011-01-01

    Objective: To compare the acute and late adverse events and quality of life (QOL) in patients with nasopharyngeal carcinomas receiving conventional external beam radiation therapy (RT) versus intensity modulated radiation therapy (IMRT). Methods: Ninety-one patients with newly diagnosed nasopharyngeal carcinoma treated in our institution between August 2008 and September 2010 were systemically reviewed, including 35 cases administered with conventional RT (RT group) and 56 cases with IMRT (IMRT group). Conjoint faciocervical fields plus tangential lower neck-supraclavicular field initially, and then shrinking preauricular portals plus electron beams to the neck were adopted in RT groups, with a total dose of 70 Gy/35 fractions.Nine coplanar fields were conducted in IMRT group with a total dose of 69.96 Gy/33 fractions. Acute and late adverse reactions were observed and compared between RT and IMRT groups, including acute reactions as xerostomia, odynophagia, dermatitis/mucositis and late events as dysphagia, trismus, hypothyroidism, optic/acoustic impairments, skin injury, hypodermal fibrosis, spinal myelitis and brain injury. Results: Compared with RT group, IMRT group showed less acute reactions in xerostomia, odynophagia, dysphagia and dermatitis and mucositis (χ 2 =85.73, 56.03, 26.58, 69.28, 55.99, P<0.05), and less late reactions in xerostomia, dysphagia, trismus, taste loss and skin injury (χ 2 =37.95, 7.48, 9.49, 9.49, 11.87, P<0.05), whereas the degree of acoustic/optic impairments and brain injury showed no difference in both groups. Conclusions: As compared to conventional RT, IMRT could decrease acute and some late side events, and improve the quality of life in patients with nasopharyngeal carcinoma. (authors)

  15. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    International Nuclear Information System (INIS)

    Burleson, S; Baker, J; Hsia, A; Xu, Z

    2014-01-01

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies

  16. Intraoperative radiotherapy electron boost followed by moderate doses of external beam radiotherapy in resected soft-tissue sarcoma of the extremities

    International Nuclear Information System (INIS)

    Azinovic, Ignacio; Martinez Monge, Rafael; Aristu, Jose Javier; Salgado, Esteban; Villafranca, Elena; Hidalgo, Oscar Fernandez; Amillo, Santiago; San Julian, Miguel; Villas, Carlos; Aramendia, Jose Manuel; Calvo, Felipe A.

    2003-01-01

    Purpose: To analyze the patterns of failure and the toxicity profile of intraoperative electron beam radiotherapy (IOERT) after resection of soft tissue sarcomas of the extremities (STS). Patients and methods: Forty-five patients with extremity STS were treated with IOERT and moderate-dose postoperative radiotherapy (45-50 Gy). Twenty-six patients were treated for primary disease (PD) and 19 patients for an isolated recurrence (ILR). Tumor size was >5 cm (maximum diameter) in 36 patients (80%), and high-grade histology in PD patients was present in 14 patients (54%). In nine patients, IOERT was used alone, due to previous irradiation or patient refusal. Chemotherapy (neoadjuvant and/or adjuvant) was mainly given to high-grade tumors. Results: Nine patients relapsed in the extremity (20%), and 12 patients in distant sites (28%). Actuarial local control at 5 years was 88% for patients with negative/close margins and 57% for patients presenting positive margins (P=0.04). Five patients (11%) developed neuropathy associated with the treatment. Extremity preservation was achieved in 40 patients (88%). With a median follow-up of 93 months (range: 27-143 months) for the patients at risk, 25 patients remain alive (a 7-year actuarial survival rate of 75% for PD and 47% for ILR; P=0.01). Conclusions: IOERT combined with moderate doses of external beam irradiation yields high local control and extremity preservation rates in resected extremity STS. Peripheral nerves in the IOERT field are dose-limiting structures requiring a dose compromise in the IOERT component to avoid severe neurological damage

  17. Results of a phase II trial of external beam radiation with etanidazole (SR 2508) for the treatment of locally advanced prostate cancer (RTOG protocol 90-20)

    International Nuclear Information System (INIS)

    Lawton, Colleen A.; Coleman, C. Norman; Buzydlowski, Jan W.; Forman, Jeffrey D.; Marcial, Victor A.; DelRowe, John D.; Rotman, Marvin

    1996-01-01

    Purpose: RTOG Protocol 90-20 was designed to evaluate the effect of the hypoxic cell sensitizer Etanidazole (SR-2508) on locally advanced adenocarcinoma of the prostate treated with concurrent external beam irradiation. Methods and Materials: Patients with biopsy-proven adenocarcinoma of the prostate with locally advanced T 2b , T 3 , and T 4 tumors were eligible for this study. No patients with disease beyond the pelvis were eligible. Serum prostate specific antigen (PSA) was mandatory. All patients received definitive external beam irradiation using standard four-field whole pelvis treatment to 45-50 Gy, followed by a cone down with a minimum total dose to the prostate of 66 Gy at 1.8-2.0 Gy/fraction over 6.5-7.5 weeks. Etanidazole was delivered 1.8 g/m 2 given 3 times a week to a total of 34.2 g/m 2 or 19 doses. Results: Thirty-nine patients were entered onto the study. Three patients refused treatment; therefore, 36 patients were eligible for further evaluation. Median follow-up was 36.9 months from treatment end. All patients had elevated initial PSA levels, and 18 patients had PSAs of > 20 ng/ml. Tumor classification was T 2 , 12 patients (33.3%); T 3 , 22 patients (61.1%); and T 4 , 2 patients (5.6%). Complete clinical response, defined as PSA < 4 ng/ml and complete clinical disappearance, was attained in 17.9% of ((5(28)) pts) with information at 90 days and 56% of patients by 12 months following treatment. Relapse-free survival was 13% at 3 years with PSA < 4 ng/ml. There were no Grade 4 or 5 toxicities, either acute (during treatment) or in follow-up. Conclusions: Results of this trial regarding PSA response and clinical disappearance of disease are similar to historical controls and do not warrant further investigation of etanidazole as was done in this trial. Drug toxicity that, in the past, has been unacceptably high with other hypoxic cell sensitizers does not appear to be a significant problem with this drug

  18. The correlation between the ASTRO consensus panel definition of biochemical failure and clinical outcome for patients with prostate cancer treated with external beam irradiation

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Vicini, Frank A.; Ziaja, Ellen L.; Dmuchowski, Carl F.; Stromberg, Jannifer S.; Martinez, Alvaro A.

    1998-01-01

    Purpose: We reviewed our institution's experience treating patients with external beam irradiation (RT) to determine if the ASTRO Consensus Panel definition of biochemical failure (BF) following radiation therapy correlates with clinical distant metastases free survival (DMFS), disease-free survival (DFS), cause-specific survival (CSS), and local control (LC). Methods and Materials: Between 1/1/87 and 12/31/92, 568 patients with clinically localized prostate cancer received external beam irradiation (RT) using localized prostate fields at William Beaumont Hospital (median total dose 66.6 Gy; range: 60-70.4 Gy). Biochemical failure was defined as three consecutive increases in post-treatment prostate specific antigen (PSA) after achieving a nadir. Biochemical failure was recorded as the time midway between the nadir and the first rising PSA. Five-year actuarial rates of clinical DMFS, DFS, CSS, and LC were calculated for patients who were biochemically controlled (BC) versus those who failed biochemically. Median follow-up was 56 months (range: 24-118 months). Results: Five-year actuarial rates of DMFS, DFS, CSS, and LC were significantly greater in patients who were biochemically controlled versus those who were not (p < 0.001). In patients who were BC, the 5-year actuarial rates of DMFS, DFS, CSS, and LC were 99%, 99%, 98%, and 99% respectively. For patients who failed biochemically, the 5-year actuarial rates of DMFS, DFS, CSS, and LC were 74%, 64%, 89%, and 86% respectively. When stratifying by pretreatment PSA, Gleason score, and T stage these differences remained significant for DMFS, DFS, and CSS. The Cox proportional hazards model demonstrated that BC was the single most important predictor of clinical outcome for DMFS, DFS, CSS, and LC. Pretreatment PSA and Gleason score were also independent predictors of outcome for DMFS and DFS. Conclusions: The ASTRO Consensus Panel definition of BF following radiation therapy correlates well with clinical DMFS, DFS

  19. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  20. WE-G-BRE-06: New Potential for Enhancing External Beam Radiotherapy for Lung Cancer Using FDA-Approved Concentrations of Cisplatin Or Carboplatin Nanoparticles Administered Via Inhalation

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Y; Altundal, Y; Sajo, E [University Massachusetts Lowell, Lowell, MA (United States); Detappe, A [Brigham ' Woman' s Hospital, Boston, MA (United States); Dana Farber Cancer Institute, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); University of Lyon, Lyon (France); Makrigiorgos, G; Berbeco, R [Brigham ' Woman' s Hospital, Boston, MA (United States); Dana Farber Cancer Institute, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Ngwa, W [University Massachusetts Lowell, Lowell, MA (United States); Brigham ' Woman' s Hospital, Boston, MA (United States); Dana Farber Cancer Institute, Boston, MA (United States); Harvard Medical School, Boston, MA (United States)

    2014-06-15

    Purpose: This study investigates, for the first time, the dose enhancement to lung tumors due to cisplatin nanoparticles (CNPs) and carboplatin nanoparticles (CBNPs) administered via inhalation route (IR) during external beam radiotherapy. Methods: Using Monte Carlo generated 6 MV energy fluence spectra, a previously employed analytic method was used to estimate dose enhancement to lung tumor due to radiation-induced photoelectrons from CNPs administered via IR in comparison to intravenous (IV) administration. Previous studies have indicated about 5% of FDA-approved cisplatin concentrations reach the lung tumor via IV. Meanwhile recent experimental studies indicate that 3.5–14.6 times higher concentrations of CNPs can reach the lung tumors by IR compared to IV. Taking these into account, the dose enhancement factor (DEF) defined as the ratio of the dose with and without CNPs was calculated for field size of 10 cm × 10 cm (sweeping gap), for a range of tumor depths and tumor sizes. Similar calculations were done for CBNPs. Results: For IR with 3.5 times higher concentrations than IV, and 2 cm diameter tumor, clinically significant DEF values of 1.19–1.30 were obtained for CNPs at 3–10 cm depth, respectively, in comparison to 1.06–1.09 for IV. For CBNPs, DEF values of 1.26–1.41 were obtained in comparison to 1.07–1.12 for IV. For IR with 14.6 times higher concentrations, higher DEF values were obtained e.g. 1.81–2.27 for CNPs. DEF increased with increasing field size or decreasing tumor size. Conclusions: Our preliminary results indicate that major dose enhancement to lung tumors can be achieved using CNPs/CBNPs administered via IR, in contrast to IV administration during external beam radiotherapy. These findings highlight a potential new approach for radiation boosting to lung tumors using CNPs/CBNPs administered via IR. This would, especially, be applicable during concomitant chemoradiotherapy, potentially allowing for dose enhancement while

  1. Evaluation of Delivery Costs for External Beam Radiation Therapy and Brachytherapy for Locally Advanced Cervical Cancer Using Time-Driven Activity-Based Costing.

    Science.gov (United States)

    Bauer-Nilsen, Kristine; Hill, Colin; Trifiletti, Daniel M; Libby, Bruce; Lash, Donna H; Lain, Melody; Christodoulou, Deborah; Hodge, Constance; Showalter, Timothy N

    2018-01-01

    To evaluate the delivery costs, using time-driven activity-based costing, and reimbursement for definitive radiation therapy for locally advanced cervical cancer. Process maps were created to represent each step of the radiation treatment process and included personnel, equipment, and consumable supplies used to deliver care. Personnel were interviewed to estimate time involved to deliver care. Salary data, equipment purchasing information, and facilities costs were also obtained. We defined the capacity cost rate (CCR) for each resource and then calculated the total cost of patient care according to CCR and time for each resource. Costs were compared with 2016 Medicare reimbursement and relative value units (RVUs). The total cost of radiation therapy for cervical cancer was $12,861.68, with personnel costs constituting 49.8%. Brachytherapy cost $8610.68 (66.9% of total) and consumed 423 minutes of attending radiation oncologist time (80.0% of total). External beam radiation therapy cost $4055.01 (31.5% of total). Personnel costs were higher for brachytherapy than for the sum of simulation and external beam radiation therapy delivery ($4798.73 vs $1404.72). A full radiation therapy course provides radiation oncologists 149.77 RVUs with intensity modulated radiation therapy or 135.90 RVUs with 3-dimensional conformal radiation therapy, with total reimbursement of $23,321.71 and $16,071.90, respectively. Attending time per RVU is approximately 4-fold higher for brachytherapy (5.68 minutes) than 3-dimensional conformal radiation therapy (1.63 minutes) or intensity modulated radiation therapy (1.32 minutes). Time-driven activity-based costing was used to calculate the total cost of definitive radiation therapy for cervical cancer, revealing that brachytherapy delivery and personnel resources constituted the majority of costs. However, current reimbursement policy does not reflect the increased attending physician effort and delivery costs of brachytherapy. We

  2. The correlation between the astro consensus panel definition of biochemical failure and clinical outcome for patients with prostate cancer treated with external beam irradiation

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Vicini, Frank A.; Ziaja, Ellen L.; Dmuchowski, Carl F.; Stromberg, Jannifer S.; Matter, Richard C.; Martinez, Alvaro A.

    1997-01-01

    Purpose: The ASTRO Consensus Panel on PSA After Radiation Therapy recently recommended a definition of biochemical failure (BF) following treatment of prostate cancer with radiation therapy. We reviewed our institution's experience treating patients with external beam irradiation (RT) to determine if the Consensus Panel definition correlates with clinical distant metastases free survival (DMFS), disease free survival (DFS), cause specific survival (CSS), and local control (LC) rates for a large group of patients from the PSA era. Methods And Materials: Between 1/1/87 and 12/31/92, 653 patients with clinically localized prostate cancer received external beam irradiation (RT) using localized prostate fields at William Beaumont Hospital. Of these patients, 568 had a minimum follow-up of 2 years and constitute the study population. The median pre-treatment PSA and Gleason score was 11 ng/ml and 6, respectively. The median dose to the prostate using megavoltage RT was 66.6 Gy (range: 60-70.4 Gy) using a four field or arc technique. No patient received hormonal therapy either prior to, during, or after radiotherapy unless local or distant failure was documented. Pre-treatment and post-treatment serum PSA levels were recorded. Biochemical failure was defined as three consecutive increases in post-treatment PSA after achieving a nadir. Biochemical failure was recorded as the time midway between the nadir and first increase in PSA. Five year actuarial rates of DMFS, DFS, CSS, and LC were calculated for patients who were biochemically controlled (BC) versus those who failed biochemically. Results: Median follow-up was 56 months (range: 24-118 months). The overall 5 year actuarial rates of DMFS, DFS, CSS, and LC were significantly better in patients who were biochemically controlled versus those who were not (p< 0.001). The median time to DM within the BF group was 21 months (range: 2-112 months). When stratifying by pre-treatment PSA, Gleason score, and T stage, these

  3. Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.

    Science.gov (United States)

    Durack, C; Patel, S; Davies, J; Wilson, R; Mannocci, F

    2011-02-01

    To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. Small and large simulated external inflammatory resorption (EIR) lesions were created on the roots of 10 mandibular incisor teeth from three human mandibles. Small volume CBCT scans with 180° and 360° of X-ray source rotation and periapical radiographs, using a digital photostimulable phosphor plate system, were taken prior to and after the creation of the EIR lesions. The teeth were relocated in their original sockets during imaging. Receiver operator characteristic (ROC) analysis and kappa tests of the reproducibility of the imaging techniques were carried out and sensitivity, specificity, positive and negative predictive values (PPV and NPV) were also determined for each technique. The overall area under the ROC curve (Az value) for intraoral radiography was 0.665, compared to Az values of 0.984 and 0.990 for 180° and 360° CBCT, respectively (Pradiography (Pperiapical radiography. The intra- and inter-examiner agreement was significantly better for CBCT than it was for intraoral radiography (Pperiapical radiographs (Pperiapical radiography. Small volume CBCT operating with 360° of rotation of the X-ray source and detector is no better at detecting small, artificially created EIR cavities than the same device operating with 180° of rotation. © 2010 International Endodontic Journal.

  4. A consensus-based guideline defining the clinical target volume for pelvic lymph nodes in external beam radiotherapy for uterine cervical cancer

    International Nuclear Information System (INIS)

    Toita, Takafumi; Ohno, Tatsuya; Kaneyasu, Yuko

    2010-01-01

    The objective of this study was to develop a consensus-based guideline as well as an atlas defining pelvic nodal clinical target volumes in external beam radiotherapy for uterine cervical cancer. A working subgroup to establish the consensus-based guideline on clinical target volumes for uterine cervical cancer was formulated by the Radiation Therapy Study Group of the Japan Clinical Oncology Group in July 2008. The working subgroup consisted of seven radiation oncologists. The process resulting in the consensus included a comparison of contouring on CT images among the members, reviewing of published textbooks and the relevant literature and a distribution analysis of metastatic nodes on computed tomography/magnetic resonance imaging of actual patients. The working subgroup defined the pelvic nodal clinical target volumes for cervical cancer and developed an associated atlas. As a basic criterion, the lymph node clinical target volume was defined as the area encompassed by a 7 mm margin around the applicable pelvic vessels. Modifications were made in each nodal area to cover adjacent adipose tissues at risk of microscopic nodal metastases. Although the bones and muscles were excluded, the bowel was not routinely excluded in the definition. Each of the following pelvic node regions was defined: common iliac, external iliac, internal iliac, obturator and presacral. Anatomical structures bordering each lymph node region were defined for six directions; anterior, posterior, lateral, medial, cranial and caudal. Drafts of the definition and the atlas were reviewed by members of the JCOG Gynecologic Cancer Study Group (GCSG). We developed a consensus-based guideline defining the pelvic node clinical target volumes that included an atlas. The guideline will be continuously updated to reflect the ongoing changes in the field. (author)

  5. Long-term Follow-up Results of a Multi-institutional Phase 2 Study of Concurrent Chemoradiation Therapy for Locally Advanced Cervical Cancer in East and Southeast Asia

    International Nuclear Information System (INIS)

    Kato, Shingo; Ohno, Tatsuya; Thephamongkhol, Kullathorn; Chansilpa, Yaowalak; Cao, Jianping; Xu, Xiaoting; Devi, C. R. Beena; Swee, Tang Tieng; Calaguas, Miriam J.C.; Reyes, Rey H. de los; Cho, Chul-Koo; Dung, To Anh; Supriana, Nana; Erawati, Dyah; Mizuno, Hideyuki; Nakano, Takashi; Tsujii, Hirohiko

    2013-01-01

    Purpose: To report the long-term survival and toxicity of a multi-institutional phase 2 study of concurrent chemoradiation therapy (CCRT) for locally advanced cervical cancer in east and southeast Asia. Methods and Materials: Ten institutions from 8 Asian countries participated in the study. Between April 2003 and March 2006, 120 patients (60 with bulky stage IIB and 60 with stage IIIB) were treated with CCRT. Radiation therapy consisted of pelvic external beam radiation therapy and either high-dose-rate or low-dose-rate intracavitary brachytherapy. Five cycles of weekly cisplatin (40 mg/m 2 ) were administered during the course of radiation therapy. Treatment results were evaluated by the rates of local control, overall survival, and late toxicities. Results: Median follow-up was 63.7 months, and the follow-up rate at 5 years was 98%. The 5-year local control and overall survival rates for all patients were 76.8% and 55.1%, respectively. The 5-year rates of major late toxicities of the rectum and bladder were 7.9% and 0%, respectively. Conclusions: The long-term results have suggested that CCRT is safe and effective for patients with locally advanced cervical cancer in east and southeast Asia. However, further efforts are needed to improve overall survival

  6. Preoperative chemoradiation using oral capecitabine in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Kim, Jun-Sang; Kim, Jae-Sung; Cho, Moon-June; Song, Kyu-Sang; Yoon, Wan-Hee

    2002-01-01

    Purpose: Capecitabine (Xeloda) is a new orally administered fluoropyrimidine carbamate that was rationally designed to exert its effect by tumor-selective activation. We attempted to evaluate the efficacy and toxicity of preoperative chemoradiation using capecitabine in locally advanced rectal cancer. Methods and Materials: Between July 1999 and March 2001, 45 patients with locally advanced rectal cancer (cT3/T4 or N+) were treated with preoperative chemoradiation. Radiation of 45 Gy/25 fractions was delivered to the pelvis, followed by a 5.4 Gy/3 fractions boost to the primary tumor. Chemotherapy was administered concurrent with radiotherapy and consisted of 2 cycles of 14-day oral capecitabine (1650 mg/m 2 /day) and leucovorin (20 mg/m 2 /day), each of which was followed by a 7-day rest period. Surgery was performed 6 weeks after the completion of chemoradiation. Results: Thirty-eight patients received definitive surgery. Primary tumor and node downstaging occurred in 63% and 90% of patients, respectively. The overall downstaging rate, including both primary tumor and nodes, was 84%. A pathologic complete response was achieved in 31% of patients. Twenty-one patients had tumors located initially 5 cm or less from the anal verge; among the 18 treated with surgery, 72% received sphincter-preserving surgery. No Grade 3 or 4 hematologic toxicities developed. Other Grade 3 toxicities were as follows: hand-foot syndrome (7%), fatigue (4%), diarrhea (4%), and radiation dermatitis (2%). Conclusion: These preliminary results suggest that preoperative chemoradiation with capecitabine is a safe, well-tolerated, and effective neoadjuvant treatment modality for locally advanced rectal cancer. In addition, this preoperative treatment has a considerable downstaging effect on the tumor and can increase the possibility of sphincter preservation in distal rectal cancer

  7. Ultrasound elastography in patients with rectal cancer treated with chemoradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rafaelsen, S.R., E-mail: soeren.rafael.rafaelsen@slb.regionsyddanmark.dk [Department of Radiology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark); Vagn-Hansen, C., E-mail: chris.aksel.vagn-hansen@slb.regionsyddanmark.dk [Department of Radiology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark); Sørensen, T., E-mail: torben.soerensen@slb.regionsyddanmark.dk [Department of Radiology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark); Lindebjerg, J., E-mail: jan.lindebjerg@slb.regionsyddanmark.dk [Department of Pathology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark); Pløen, J., E-mail: john.ploeen@slb.regionsyddanmark.dk [Department of Oncology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark); Jakobsen, A., E-mail: anders.jakobsen@slb.regionsyddanmark.dk [Department of Oncology, DCCG South, Vejle Hospital, 7100 Vejle (Denmark)

    2013-06-15

    Objective: The current literature has described several predictive markers in rectal cancer patients treated with chemoradiation, but so far none of them have been validated for clinical use. The purpose of the present study was to compare quantitative elastography based on ultrasound measurements in the course of chemoradiation with tumor response based on T stage classification and the Mandard tumor regression grading (TRG). Materials and methods: We prospectively examined 31 patients with rectal cancer planned for high dose radiochemotherapy. The tumor and the mesorectal fat elasticity were measured using the Acoustic Radiation Force Impulse to generate information on the mechanical properties of the tissue. The objective quantitative elastography shear wave velocity was compared to the T stage classification and TRG. Results: The baseline mean tumor elasticity was 3.13 m/s. Two and six weeks after the start of chemoradiation the velocities were 2.17 m/s and 2.11 m/s, respectively. The difference between baseline velocity and velocities during the treatment course was statistically significant, (p < 0.0001). Patients with tumor confined to the rectal wall at histopathology (ypT1-2) had a mean elasticity measurement after two weeks of treatment of 1.95 m/s, whereas tumors invading the mesorectal fat (ypT3-4) had a velocity of 2.47 m/s, (p < 0.05). The mean elasticity tended to be lower (1.99 m/s) after two weeks in patients with TRG 1–2 responses in contrast to 2.24 m/s in those with TRG 3–4. Conclusion: Ultrasound elastography after two weeks of chemoradiation seems to hold early predictive information to the pathological T stage.

  8. The role of sequential chemoradiation for local advanced oropharyngeal carcinoma

    International Nuclear Information System (INIS)

    Masterson, Liam; Tanweer, Faiz

    2013-01-01

    This study aims to assess survival, prognostic indicators, and pattern of failure for advanced oropharyngeal cancer treated by induction chemotherapy followed by concomitant chemoradiation (sequential CRT). A retrospective review of 80 consecutive patients who underwent chemoradiation [doublet cisplatin and 5-fluorouracil (PF)] for local advanced oropharyngeal carcinoma at a tertiary center from March 2003 to July 2008 is reported. Seven studies utilizing a similar protocol were reviewed, and all outcomes are collated. At a median follow-up of 32 months, the 3-year overall survival was 75%. Tumor size (p<0.001), age at presentation (p<0.002), and failure to complete the full course of induction chemotherapy (p<0.01) were all found to be significant factors affecting survival. Induction chemotherapy followed by concomitant chemoradiation utilizing doublet PF is an effective treatment for local advanced oropharyngeal carcinoma. At present, the addition of a taxane to the PF regimen cannot be assumed to provide benefit until further evidence emerges from a representative controlled trial. (author)

  9. Sildenafil citrate (Viagra) and erectile dysfunction following external beam radiotherapy for prostate cancer: a randomized, double-blind, placebo-controlled, cross-over study

    International Nuclear Information System (INIS)

    Incrocci, Luca; Koper, Peter C.M.; Hop, Wim C.J.; Slob, A. Koos

    2001-01-01

    Purpose: To determine the efficacy of sildenafil citrate (Viagra) in patients with erectile dysfunction after three-dimensional conformal external beam radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: 406 patients with complaints of erectile dysfunction and who completed radiation at least 6 months before the study were approached by mail. 3D-CRT had been delivered (mean dose 68 Gy). Sixty patients were included and entered a double-blind, placebo-controlled, cross-over study lasting 12 weeks. They received during 2 weeks 50 mg of sildenafil or placebo; at Week 2 the dose was increased to 100 mg in case of unsatisfactory erectile response. At Week 6, patients crossed over to the alternative treatment. Data were collected using the International Index of Erectile Function (IIEF) questionnaire, and side effects were recorded. Results: Mean age was 68 years. All patients completed the study. For most questions of the IIEF questionnaire there was a significant increase in mean scores from baseline with sildenafil, but not with placebo. Ninety percent of the patients needed a dose adjustment to 100 mg sildenafil. Side effects were mild or moderate. Conclusion: Sildenafil is well tolerated and effective in improving erectile function of patients with ED after 3D-CRT for prostate cancer

  10. Population-Based Validation of the 2014 ISUP Gleason Grade Groups in Patients Treated With Radical Prostatectomy, Brachytherapy, External Beam Radiation, or no Local Treatment.

    Science.gov (United States)

    Pompe, Raisa S; Davis-Bondarenko, Helen; Zaffuto, Emanuele; Tian, Zhe; Shariat, Shahrokh F; Leyh-Bannurah, Sami-Ramzi; Schiffmann, Jonas; Saad, Fred; Huland, Hartwig; Graefen, Markus; Tilki, Derya; Karakiewicz, Pierre I

    2017-05-01

    To test discriminant ability of the 2014 ISUP Gleason grade groups (GGG) for prediction of prostate cancer specific mortality (PCSM) after radical prostatectomy (RP), brachytherapy (BT), external beam radiation (EBRT) or no local treatment (NLT) relative to traditional Gleason grading (TGG). In the Surveillance, Epidemiology, and End Results (SEER)-database (2004-2009), 2,42,531 non-metastatic prostate cancer (PCa) patients were identified, who underwent local treatment (RP, BT, EBRT only) or NLT. Follow-up endpoint was PCSM. Biopsy and/or pathological Gleason score (GS) were categorized as TGG ≤6, 7, 8-10 or GGG: I (≤6), II (3 + 4), III (4 + 3), IV (8), and V (9-10). Kaplan-Meier plots, multivariable Cox regression analyses and receiver operating characteristics (ROC) area under the curve analyses (AUC) were used. Median follow-up was 76 months (IQR: 59-94). For the four examined treatment modalities, all five GGG strata and all three TGG strata independently predicted PCSM. GGG yielded 1.5-fold or greater HR differences between GGG II and GGG III, and twofold or greater HR differences between GGG IV and GGG V. Relative to TGG, GGG added 0.4-1.1% to AUC. This large population-based cohort study confirms the added discriminant properties of the novel GGG strata and confirms a modest gain in predictive accuracy. Prostate 77: 686-693, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. External root resorption of the second molar associated with third molar impaction: comparison of panoramic radiography and cone beam computed tomography.

    Science.gov (United States)

    Oenning, Anne Caroline Costa; Neves, Frederico Sampaio; Alencar, Phillipe Nogueira Barbosa; Prado, Rodrigo Freire; Groppo, Francisco Carlos; Haiter-Neto, Francisco

    2014-08-01

    The aim of the present study was to compare panoramic radiography and cone beam computed tomography (CBCT) for the assessment of external root resorption (ERR) of second molars associated with impacted third molars. In addition, the prevalence of ERR in second molars and the inclinations of the third molars more associated with ERR were investigated in both imaging methods. The sample consisted of 66 individuals with maxillary and mandibular impacted third molars (n = 188) seen on panoramic radiographs and CBCT images. The presence of ERR on the adjacent second molar was investigated, and the position of the third molar was determined using Winter's classification (vertical, horizontal, mesioangular, distoangular, and transverse). Statistical analysis was performed using the χ(2) test, Fisher exact test, and 2-proportion Z test (the significance level was set at 5%). A significantly greater number of cases of ERR (P panoramic radiographs (n = 10, 5.31%). The agreement between the panoramic radiographs and CBCT scans for diagnosing ERR was 4.3%. Mandibular third molars in mesioangular and horizontal inclinations were more likely to cause resorption of the adjacent teeth. CBCT should be indicated for the diagnosis of ERR in second molars when direct contact between the mandibular second and third molars has been observed on panoramic radiographs, especially in mesioangular or horizontal impactions. Furthermore, considering the propensity of these teeth to cause ERR in second molars, third molar prophylactic extraction could be suggested. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Comparison of diagnostic accuracy of root perforation, external resorption and fractures using cone-beam computed tomography, panoramic radiography and conventional & digital periapical radiography.

    Science.gov (United States)

    Takeshita, Wilton Mitsunari; Chicarelli, Mariliani; Iwaki, Lilian Cristina Vessoni

    2015-01-01

    Some radicular changes are challenging for clinicians to diagnose, such as of root perforations, external root resorption (ERR), and vertical root fractures (VRFs). This study aims to facilitate it by comparing the diagnostic accuracy of cone-beam computed tomography (CBCT), orthopantomography, and conventional and digital periapical radiography (DPR) in the diagnosis of such problems. Is it worth doing CBCT despite the radiation dose? To evaluate and compare the diagnostic accuracy of CBCT, panoramic radiography, and conventional and DPR in the diagnosis of root perforation (RP), ERR, and VRF. The sample consisted of 40 extracted human teeth and 10 macerated human mandibles. RPs were performed using diamond burs, ERRs using spherical carbide burs, and RFs using a universal machine EMIC-DL 1000. The images were evaluated by 6 dentomaxillofacial radiologists. Receiver operating characteristic (ROC) revealed that CBCT showed the highest area under the ROC curve (Az) values for RP, ERR, and VRF (0.903, 0.950, and 0.849, respectively). The worst Az values for RP, ERR, and VRF (0.718, 0.494, and 0.611, respectively) were for panoramic radiography. CBCT showed the best results in the diagnosis of ERR and VRF. The diagnosis of ERR was the least accurate, panoramic radiography being not appropriate for its diagnosis. CBCT and conventional periapical radiography obtained similar results for the evaluation of RP. So for, RP indicate the conventional periapical radiography because CBCT has a higher radiation dose.

  13. A comparison in cosmetic outcome between per-operative interstitial breast implants and delayed interstitial breast implants after external beam radiotherapy

    International Nuclear Information System (INIS)

    Pieters, Bradley R.; Hart, Augustinus A.M.; Russell, Nicola S.; Jansen, Edwin P.M.; Peterse, Johannes L.; Borger, Jacques; Rutgers, Emiel J.Th.

    2003-01-01

    Background and purpose: Interstitial implants for brachytherapy boost in the breast conserving therapy of breast cancer can be performed in two ways; implants during the tumor excision (per-operative implants) or after the external beam therapy (delayed interstitial implants). Differences in cosmetic outcome were investigated. Patients and methods: Cosmetic results in 47 patients having a per-operative implant were compared to 123 patients having a delayed interstitial implant in a matched case-control study. Cosmesis was scored on a four-point-scale varying from 0 (excellent) to 3 (poor). Results: After mean follow-up of 63 months, three observers found no difference in cosmetic outcome between the two groups after adjustment for variables found to be related with cosmesis (difference in mean score 0.50, P=0.26). Implant volume at 100% isodose was not found to differ (P=0.084) between the per-operative group (mean 102 cm 3 , S.D. 34 cm 3 ) and the delayed group (mean 93 cm 3 , S.D. 29 cm 3 ). Conclusions: Performing per-operative implants has not led to smaller implants. The method of performing brachytherapy does not result in marked differences in cosmetic outcome

  14. 3D conformal HDR-brachy- and external beam therapy plus simultaneous Cisplatin for high-risk cervical cancer: Clinical experience with 3 year follow-up

    International Nuclear Information System (INIS)

    Poetter, Richard; Dimopoulos, Johannes; Bachtiary, Barbara; Sissolak, Gerhard; Klos, Beata; Rheinthaller, A.; Kirisits, C.; Knocke-Abulesz, Tomas-Hendrik

    2006-01-01

    Background and purpose: To assess feasibility, safety and effectiveness of CT-based 3D conformal external beam radiotherapy (EBRT) plus concurrent cisplatin and MRI-based 3D conformal HDR-brachytherapy (HDR-BT) in the treatment of advanced cervical cancer. Patients and methods: A total of 48 patients with advanced cervical cancer, treated with CT-based EBRT plus simultaneous cisplatin chemotherapy (40 mg/m 2 of body surface per week for 5 weeks) and MRI-based HDR-BT, were included for analysis. Results: All patients completed radiotherapy as planned and 90% received at least four cycles chemotherapy. Frequencies of CTC grade 3 anaemia, grade 3-4 leucopenia and grade 3 thrombocytopenia were 4, 23 and 10%, respectively. Two patients developed deep vein thrombosis and one non-fatal pulmonary embolism. Grade 4 genitourinary late side effects (bladder) occurred in 2 patients. No grade 3-4 gastrointestinal side effects were observed. Complete response (CR) was obtained in 45 patients (94%). After a median follow-up of 33 months, 27 patients were disease free. Actuarial overall survival at 3 years was 61%, progression free survival 51% and continuous complete remission for true pelvis 85%. Conclusions: MRI-based 3D HDR-BT and 3D EBRT plus cisplatin appears to be safe and effective, although acute haematological toxicity is increased. Gastrointestinal morbidity is minimal when prospectively applying 3D dose volume constraints and MRI-based 3D dose volume adaptation

  15. Hemoglobin levels do not predict biochemical outcome for localized prostate cancer treated with neoadjuvant androgen-suppression therapy and external-beam radiotherapy

    International Nuclear Information System (INIS)

    Pai, Howard Huaihan; Ludgate, Charles; Pickles, Tom; Paltiel, Chuck M.Sc.; Agranovich, Alex; Berthelet, Eric; Duncan, Graeme; Kim-Sing, Charmaine; Kwan, Winkle; Lim, Jan; Liu, Mitchell; Tyldesley, Scott

    2006-01-01

    Purpose: To investigate whether hemoglobin (Hb) levels affect outcome in men with localized prostate adenocarcinoma (LPA) treated with neoadjuvant androgen-suppression therapy (NAST) and external-beam radiotherapy (EBRT). Methods and Materials: A total of 563 men with LPA treated with NAST (median: 5.3 months) and EBRT who had Hb levels during treatment were retrospectively reviewed. Patient, tumor, and treatment variables, including the following Hb variables, were subjected to univariate and multivariable analyses to identify factors that predict biochemical control (bNED) and overall survival (OS): pre-EBRT Hb, Hb nadir during EBRT, and change in Hb from pre-EBRT to nadir during EBRT. Results: Median PSA follow-up was 4.25 years. Forty-nine percent of men were anemic during EBRT, with a median Hb of 13.4 g/dL, and 68% experienced a decline in Hb from pre-EBRT to during EBRT of median 0.6 g/dL. Five-year Nadir + 2 bNED and OS rates were similar for anemic and nonanemic patients during EBRT. High percent-positive biopsies, PSA and Gleason score, and use of AA monotherapy predicted worse bNED. High stage and age predicted worse OS. Hb variables were not predictive of bNED or OS. Conclusions: Anemia is a common side effect of NAST and is usually mild. Hb levels, however, do not predict biochemical control or survival

  16. Additional androgen deprivation makes the difference. Biochemical recurrence-free survival in prostate cancer patients after HDR brachytherapy and external beam radiotherapy

    International Nuclear Information System (INIS)

    Schiffmann, Jonas; Tennstedt, Pierre; Beyer, Burkhard; Boehm, Katharina; Tilki, Derya; Salomon, Georg; Graefen, Markus; Lesmana, Hans; Platz, Volker; Petersen, Cordula; Kruell, Andreas; Schwarz, Rudolf

    2015-01-01

    The role of additional androgen deprivation therapy (ADT) in prostate cancer (PCa) patients treated with combined HDR brachytherapy (HDR-BT) and external beam radiotherapy (EBRT) is still unknown. Consecutive PCa patients classified as D'Amico intermediate and high-risk who underwent HDR-BT and EBRT treatment ± ADT at our institution between January 1999 and February 2009 were assessed. Multivariable Cox regression models predicting biochemical recurrence (BCR) were performed. BCR-free survival was assessed with Kaplan-Meier analyses. Overall, 392 patients were assessable. Of these, 221 (56.4 %) underwent trimodality (HDR-BT and EBRT and ADT) and 171 (43.6 %) bimodality (HDR-BT and EBRT) treatment. Additional ADT administration reduced the risk of BCR (HR: 0.4, 95 % CI: 0.3-0.7, p < 0.001). D'Amico high-risk patients had superior BCR-free survival when additional ADT was administered (log-rank p < 0.001). No significant difference for BCR-free survival was recorded when additional ADT was administered to D'Amico intermediate-risk patients (log-rank p = 0.2). Additional ADT administration improves biochemical control in D'Amico high-risk patients when HDR-BT and EBRT are combined. Physicians should consider the oncological benefit of ADT administration for these patients during the decision-making process. (orig.) [de

  17. Five year biochemical recurrence free survival for intermediate risk prostate cancer after radical prostatectomy, external beam radiation therapy or permanent seed implantation.

    Science.gov (United States)

    Vassil, Andrew D; Murphy, Erin S; Reddy, Chandana A; Angermeier, Kenneth W; Altman, Andrew; Chehade, Nabil; Ulchaker, James; Klein, Eric A; Ciezki, Jay P

    2010-11-01

    To compare biochemical recurrence-free survival (bRFS) for patients with intermediate-risk prostate cancer treated by retropubic radical prostatectomy (RRP), laparoscopic radical prostatectomy (LRP), external beam radiation therapy (RT), or permanent seed implantation (PI). Patients treated for intermediate-risk prostate cancer per National Comprehensive Cancer Network guidelines from 1996 to 2005 were studied. Variables potentially affecting bRFS were examined using univariate and multivariate Cox regression analysis. Five-year bRFS rates were calculated by actuarial methods; bRFS was calculated using Kaplan-Meier analysis. Nadir +2 definition of biochemical failure was used for RT and PI patients; a PSA ≥ 0.4 ng/mL was used for radical prostatectomy (RP) patients. Time to initiation of salvage therapy was compared for each treatment group using the Kruskal-Wallis test. Nine-hundred seventy-nine patients were analyzed with a median follow-up of 65 months. Five years bRFS rate was 82.8% for all patients (89.5% PI, 85.7% RT, 79.9% RRP, and 60.2% LRP). Patients treated by LRP had significantly worse bRFS than RT (P PI (P PSA tests per year (P PI, 47.8 RT; P PI, RT, or RRP appear to have improved 5-year bRFS and delayed salvage therapy compared with LRP. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Location-allocation model for external beam radiotherapy as an example of an evidence-based management tool implemented in healthcare sector in Poland.

    Science.gov (United States)

    Czerwiński, Adam Michał; Więckowska, Barbara

    2018-02-21

    External beam radiotherapy (EBRT) is one of three key treatment modalities of cancer patients. Its utilisation and outcomes depend on a plethora of variables, one of which is the distance a patient must travel to undergo the treatment. The relation between distance and utilisation is clearly visible in Poland. At the same time no strategic investment plan is observed. This work proposes a method of resolving these two issues. We propose a mixed-integer linear programming model that aims to optimise the distribution of linear accelerators among selected locations in such a way that a patient's journey to the nearest EBRT is as short as possible. The optimisation is done with observance of international guidelines concerning EBRT capacity. With the use of proposed theoretical framework, we develop a national, strategic plan for linear accelerator investments. According to model assumptions decentralisation of EBRT, together with new equipment purchases, is required to ensure optimal access to EBRT. The results were incorporated into Healthcare Needs Maps for Poland. The plan based on the results of this study, implemented by 2025, should deal with the most pressing concerns of Polish EBRT. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A 4D ultrasound real-time tracking system for external beam radiotherapy of upper abdominal lesions under breath-hold

    Energy Technology Data Exchange (ETDEWEB)

    Sihono, Dwi Seno Kuncoro; Vogel, Lena; Thoelking, Johannes; Wenz, Frederik; Boda-Heggemann, Judit; Wertz, Hansjoerg [University of Heidelberg, Department of Radiation Oncology, University Medical Center Mannheim, Mannheim (Germany); Weiss, Christel [University of Heidelberg, Department of Biomathematics and Medical Statistics, University Medical Center Mannheim, Mannheim (Germany); Lohr, Frank [University of Heidelberg, Department of Radiation Oncology, University Medical Center Mannheim, Mannheim (Germany); Az. Ospedaliero-Universitaria di Modena, Struttura Complessa di Radioterapia, Dipartimento di Oncologia, Modena (Italy)

    2017-03-15

    To evaluate a novel four-dimensional (4D) ultrasound (US) tracking system for external beam radiotherapy of upper abdominal lesions under computer-controlled deep-inspiration breath-hold (DIBH). The tracking accuracy of the research 4D US system was evaluated using two motion phantoms programmed with sinusoidal and breathing patterns to simulate free breathing and DIBH. Clinical performance was evaluated with five healthy volunteers. US datasets were acquired in computer-controlled DIBH with varying angular scanning angles. Tracked structures were renal pelvis (spherical structure) and portal/liver vein branches (non-spherical structure). An external marker was attached to the surface of both phantoms and volunteers as a secondary object to be tracked by an infrared camera for comparison. Phantom measurements showed increased accuracy of US tracking with decreasing scanning range/increasing scanning frequency. The probability of lost tracking was higher for small scanning ranges (43.09% for 10 and 13.54% for 20 ).The tracking success rates in healthy volunteers during DIBH were 93.24 and 89.86% for renal pelvis and portal vein branches, respectively. There was a strong correlation between marker motion and US tracking for the majority of analyzed breath-holds: 84.06 and 88.41% of renal pelvis target results and 82.26 and 91.94% of liver vein target results in anteroposterior and superoinferior directions, respectively; Pearson's correlation coefficient was between 0.71 and 0.99. The US system showed a good tracking performance in 4D motion phantoms. The tracking capability of surrogate structures for upper abdominal lesions in DIBH fulfills clinical requirements. Further investigation in a larger cohort of patients is underway. (orig.) [German] Evaluation eines neuen vierdimensionalen (4D) Ultraschall(US)-Tracking-Systems fuer die externe Strahlentherapie von Oberbauchlaesionen unter computergesteuertem tiefem Atemanhalt (DIBH). Die Tracking-Genauigkeit des 4D

  20. Relationship between XRCC1 polymorphism and acute complication of chemoradiation therapy in the patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Chul; Choi, Sun Keun [Inha University College of Medicine, Incheon (Korea, Republic of); Hong, Yun Chul [Seoul National University College of Medicine, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    It is well known from clinical experience that acute complications of chemoradiation therapy vary from patients to patients. However, there are no known factors to predict these acute complications before treatment starts. The human XRCC1 gene is known as a DNA base excision repair gene. We investigated the possibilities of XRCC1 gene polymorphisms as a predictor for the acute complications of chemoradiation therapy in colorectal cancer patients. From July 1997 to June 2003, 86 colorectal cancer patients (71 rectal cancer, 13 sigmoid colon cancer and 2 colon cancer patients) were treated with chemoradiation therapy at the Department of Radiation Oncology, Inha University Hospital. Twenty-two patients were in stage B, 50 were in stage C, 8 were in stage D and 6 patients were unresectable cases. External radiation therapy was delivered with 10MV X-ray at a 1.8 Gy fraction per day for a total dose of radiation of 30.6 {approx} 59.4 Gy (median: 54 Gy). All the patients received 5-FU based chemotherapy regimen. We analyzed the acute complications of upper and lower gastrointestinal tract based on the RTOG complication scale. The initial and lowest WBC and platelet count were recorded during both the RT period and the whole treatment period. Allelic variants of the XRCC1 gene at codons 194, 280 and 399 were analyzed in the lymphocyte DNA by performing PCR-RFLP. Statistical analyses were carried out with the SAS (version 6.12) statistical package. When all the variables were assessed on the multivariate analysis, recurrent disease revealed the factors that significantly correlated with upper gastrointestinal acute complications. Arg399Gln polymorphisms of the XRCC1 gene, the radiation dose and the frequencies of chemotherapy during radiation therapy were significantly correlated with lower gastrointestinal complications. Arg399Gln polymorphisms also affected the decrease of the WBC and platelet count during radiation therapy. Although the present sample size was too small

  1. Relationship between XRCC1 polymorphism and acute complication of chemoradiation therapy in the patients with colorectal cancer

    International Nuclear Information System (INIS)

    Kim, Woo Chul; Choi, Sun Keun; Hong, Yun Chul

    2006-01-01

    It is well known from clinical experience that acute complications of chemoradiation therapy vary from patients to patients. However, there are no known factors to predict these acute complications before treatment starts. The human XRCC1 gene is known as a DNA base excision repair gene. We investigated the possibilities of XRCC1 gene polymorphisms as a predictor for the acute complications of chemoradiation therapy in colorectal cancer patients. From July 1997 to June 2003, 86 colorectal cancer patients (71 rectal cancer, 13 sigmoid colon cancer and 2 colon cancer patients) were treated with chemoradiation therapy at the Department of Radiation Oncology, Inha University Hospital. Twenty-two patients were in stage B, 50 were in stage C, 8 were in stage D and 6 patients were unresectable cases. External radiation therapy was delivered with 10MV X-ray at a 1.8 Gy fraction per day for a total dose of radiation of 30.6 ∼ 59.4 Gy (median: 54 Gy). All the patients received 5-FU based chemotherapy regimen. We analyzed the acute complications of upper and lower gastrointestinal tract based on the RTOG complication scale. The initial and lowest WBC and platelet count were recorded during both the RT period and the whole treatment period. Allelic variants of the XRCC1 gene at codons 194, 280 and 399 were analyzed in the lymphocyte DNA by performing PCR-RFLP. Statistical analyses were carried out with the SAS (version 6.12) statistical package. When all the variables were assessed on the multivariate analysis, recurrent disease revealed the factors that significantly correlated with upper gastrointestinal acute complications. Arg399Gln polymorphisms of the XRCC1 gene, the radiation dose and the frequencies of chemotherapy during radiation therapy were significantly correlated with lower gastrointestinal complications. Arg399Gln polymorphisms also affected the decrease of the WBC and platelet count during radiation therapy. Although the present sample size was too small for

  2. Short and long term behaviour of externally bonded fibre reinforced polymer laminates with bio-based resins for flexural strengthening of concrete beams

    Science.gov (United States)

    McSwiggan, Ciaran

    The use of bio-based resins in composites for construction is emerging as a way to reduce of embodied energy produced by a structural system. In this study, two types of bio-based resins were explored: an epoxidized pine oil resin blend (EP) and a furfuryl alcohol resin (FA) derived from corn cobs and sugar cane. Nine large-scale reinforced concrete beams strengthened using externally bonded carbon and glass fibre reinforced bio-based polymer (CFRP and GFRP) sheets were tested. The EP resin resulted in a comparable bond strength to conventional epoxy (E) when used in wet layup, with a 7% higher strength for CFRP. The FA resin, on the other hand, resulted in a very weak bond, likely due to concrete alkalinity affecting curing. However, when FA resin was used to produce prefabricated cured CFRP plates which were then bonded to concrete using conventional epoxy paste, it showed an excellent bond strength. The beams achieved an increase in peak load ranging from 18-54% and a 9-46% increase in yielding load, depending on the number of FRP layers and type of fibres and resin. Additionally, 137 concrete prisms with a mid-span half-depth saw cut were used to test CFRP bond durability, and 195 CFRP coupons were used to examine tensile strength durability. Specimens were conditioned in a 3.5% saline solution at 23, 40 or 50°C, for up to 240 days. Reductions in bond strength did not exceed 15%. Bond failure of EP was adhesive with traces of cement paste on CFRP, whereas that of FA was cohesive with a thicker layer of concrete on CFRP, suggesting that the bond between FA and epoxy paste is excellent. EP tension coupons had similar strength and modulus to E resin, whereas FA coupons had a 9% lower strength and 14% higher modulus. After 240 days of exposure, maximum reductions in tensile strength were 8, 19 and 10% for EP, FA and E resins, respectively. Analysis of Variance (ANOVA) was also performed to assess the significance of the reductions observed. High degrees of

  3. Cardiovascular morbidity after radiotherapy or chemoradiation in patients with cervical cancer

    NARCIS (Netherlands)

    Maduro, John; den Dekker, Heleen; Pras, Elisabeth; de Vries, E.G.; van der Zee, A.G.; Klokman, W.J.; Reyners, A.K.; van Leeuwen, F.E.; Langendijk, J.A.; de Bock, G.H.; Gietema, J.A.

    2010-01-01

    PURPOSE: To evaluate the risk of cardiovascular events (CVE) in patients with cervical cancer treated with radiotherapy or chemoradiation. METHODS AND MATERIALS: The incidence of CVE in patients treated between 1989 and 2002 by radiotherapy or chemoradiation was compared with a Dutch reference

  4. A rare late complication after concomitant chemoradiation of an oropharyngeal tumor: cervical necrotizing fasciitis

    NARCIS (Netherlands)

    Karakullukçu, Barış; van der Vlies, Dalith; Hoebers, Frank J. P.

    2012-01-01

    Chemoradiation is increasingly being used to treat locally advanced head and neck carcinomas. Possible rare complications of this treatment modality have begun to appear, as the number of treated patients increase. In this report, we present a case who underwent chemoradiation due to T3N3M0 tonsil

  5. Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Ramsey, Chester; Meeks, Sanford L.; Willoughby, Twyla R.; Forbes, Alan; Wagner, Thomas H.; Langen, Katja M.

    2005-01-01

    Purpose: The ability to obtain soft-tissue imaging in the treatment room, such as with megavoltage CT imaging, enables the observation of tumor regression during a course of external beam radiation therapy. In this current study, we report on the most extensive study looking at the rate of regression of non-small-cell lung cancers during a course of external beam radiotherapy by analyzing serial megavoltage CT images obtained on 10 patients. Methods and Materials: The analysis is performed on 10 patients treated with the Helical Tomotherapy Hi*Art device. All 10 patients had non-small-cell lung cancer. A total of 274 megavoltage CT sets were obtained on the 10 patients (average, 27 scans per patient; range, 9-35). All patients had at least a scan at beginning and at the end of treatment. The frequency of scanning was determined by the treating physician. The treatment was subsequently delivered with the Tomotherapy Hi*Art system. The gross tumor volumes (GTVs) were later contoured on each megavoltage CT scan, and tumor volumes were calculated. Although some patients were treated to draining nodal areas in addition to the primary tumor, only the primary GTVs were tracked. Response to treatment was quantified by the relative decrease in tumor volume over time, i.e., elapsed days from the first day of therapy. The individual GTVs ranged from 5.9 to 737.2 cc in volume at the start of treatment. In 6 of the 10 patients, dose recalculations were also performed to document potential variations in delivered doses within the tumors. The megavoltage CT scans were used, and the planned treatment was recalculated on the daily images. The hypothesis was that dose deposited in the target would increase throughout the course of radiotherapy because of tumor shrinkage and subsequent decreasing attenuation. Specifically, the dose received by 95% of the GTV (D 95 ) was monitored over time for each of the 6 patients treated at M.D. Anderson Cancer Center Orlando. Results: Regression

  6. The correlation of PSA nadir and biochemical freedom from cancer after external beam treatment: effects of stage, grade and pretreatment PSA groupings

    International Nuclear Information System (INIS)

    Pinover, W.H.; Hanlon, A.L.; Lee, W.R.; Hanks, G.E.

    1996-01-01

    Purpose: This study demonstrates the correlation of various post-irradiation PSA nadirs with long term biochemical freedom from disease (bNED) survival in patients treated mainly with conformal external beam radiation therapy. It also shows the effects of various groupings of pretreatment (prerx) PSA level, stage, and Gleason score on the rate of achieving a favorable PSA nadir. Materials and Methods: Three hundred forty patients with known pretreatment PSA, >2 years followup treated with radiation alone (278 conformal, 62 conventional) are reported. The median followup is 41 months (range 24 to 96 mos.). Patient grouping by pretreatment PSA levels are <10 ng/ml (143 patients), 10-19.9 ng/ml (108 patients), ≥20 ng/ml (89 patients); by palpation stage are T1C,2AB (240 patients) and T2C,3,4 (100 patients); and by differentiation are Gleason 2-4 (108 patients), Gleason 5-7 (221 patients), Gleason 8-10 (11 patients). The PSA nadir response is given for all patients, and for each of the above prerx groupings. The 5 year actuarial bNED survival is determined for all patients by PSA nadir. Biochemical failure is a PSA ≥1.5 ng/ml and rising on two consecutive measures. Multivariate analysis (MVA) is performed to determine factors predictive of favorable PSA nadir response and predictive of bNED survival. Results: The PSA nadir responses and 5 year bNED survival rates are shown in the table for all patients according to PSA nadir. 66% of patients achieved a favorable nadir (<1.0 ng/ml) which was associated with a 75%-87% 5 year bNED rate, while 34% achieved an unfavorable nadir associated with an 18-32% bNED survival rate at 5 years. The figure illustrates the dramatic separation in outcome associated with the nadir response. The table also illustrates the fraction of patients that achieve various nadir levels subdivided by prerx PSA level, palpation stage and Gleason score. A favorable PSA nadir is obtained in 90%, 63%, and 31% of patients with a prerx PSA <10, 10

  7. Accelerated partial breast irradiation with external beam three-dimensional conformal radiotherapy. Five-year results of a prospective phase II clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Mozsa, Emoeke [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Landesklinikum Wiener Neustadt, Department of Radiooncology and Radiotherapy, Wiener Neustadt (Austria); Meszaros, Norbert; Major, Tibor; Froehlich, Georgina; Stelczer, Gabor; Fodor, Janos; Polgar, Csaba [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Sulyok, Zoltan [National Institute of Oncology, Centre of Surgery, Budapest (Hungary)

    2014-05-15

    The aim of this study was to report the 5-year results of accelerated partial breast irradiation (APBI) using external beam three-dimensional conformal radiotherapy (3D-CRT). Between 2006 and 2011, 44 patients with low-risk, stage I-II breast cancer underwent breast-conserving surgery. Postoperative APBI was given by means of 3D-CRT using three to five non-coplanar fields. The total dose of APBI was 36.9 Gy (nine fractions of 4.1 Gy b.i.d.). The mean follow-up time was 58.2 months for surviving patients. Survival results, side effects, and cosmetic results were assessed. One (2.3 %) local recurrence was observed, for a 5-year actuarial rate of 3.7 %. Neither regional nor distant failure was observed. Two patients died of internal disease. The 5-year disease-free, cancer-specific, and overall survival rates were 96.3, 100, and 95.1 %, respectively. Acute side effects included grade 1 (G1) erythema in 75 %, G1 parenchymal induration in 46 %, and G1 pain in 46 % of patients. No G2 or higher acute side effect occurred. Late side effects included G1, G2, and G3 fibrosis in 44, 7, and 2 % of patients, respectively, G1 skin pigmentation in 12 %, and G1 pain in 2 %. Asymptomatic fat necrosis occurred in 14 %. Cosmetic results were rated excellent or good in 86 % of cases by the patients themselves and 84 % by the physicians. The 5-year local tumor control, toxicity profile, and cosmetic results of APBI delivered with external beam 3D-CRT are encouraging and comparable to other APBI series. (orig.) [German] Evaluation der 5-Jahres-Ergebnisse bezueglich Ueberleben, Tumorkontrolle, Nebenwirkungen und Kosmetik nach Teilbrustbestrahlung (APBI) mittels 3-D-konformaler, akzelerierter Radiotherapie (3D-CRT). Zwischen 2006 und 2011 wurden 44 Patienten mit Brustkrebs im Stadium I-II und niedrigem Risikoprofil brusterhaltend operiert. Die adjuvante, 3-D-konformale APBI wurde mittels 3-5 nonkoplanarer Feldern durchgefuehrt. Die Gesamtdosis betrug 36,9 Gy bei 9 -mal 4,1 Gy b.i.d.. Nach

  8. Failure-free survival following brachytherapy alone or external beam irradiation alone for T1-2 prostate tumors in 2222 patients: results from a single practice

    International Nuclear Information System (INIS)

    Brachman, David G.; Thomas, Theresa; Hilbe, Joseph; Beyer, David C.

    2000-01-01

    Purpose: To evaluate failure-free survival (FFS) for brachytherapy (BT) alone compared to external beam radiotherapy (EBRT) alone for Stage T1-2 Nx-No Mo patients over the same time period by a single community-based practice in the prostate-specific antigen (PSA) era. Materials and Methods: The database of Arizona Oncology Services (a multiphysician radiation oncology practice in the Phoenix metropolitan area) was reviewed for patients meeting the following criteria: (1) T1 or T2 Nx-No Mo prostate cancer; (2) no prior or concurrent therapy including hormones; (3) treatment period 12/88-12/95; and (4) treatment with either EBRT alone or BT alone ( 125 I or 103 Pd). This yielded 1527 EBRT and 695 BT patients; no patients meeting the above criteria were excluded from analysis. Median follow-up for EBRT patients was 41.3 months and, for BT patients, 51.3 months. Patients were not randomized to either therapy but rather received EBRT or BT based upon patient, treating, and/or referring physician preference. PSA failure was defined according to the ASTRO consensus guidelines. The median patient age was 74 years for both groups. Results: Failure-free survival at 5 years for EBRT and BT are 69% and 71%, respectively (p = 0.91). For T stage, no significant difference in FFS at 5 years is observed between EBRT and BT for either T1 (78% vs. 83%, p = 0.47) or T2 (67% vs. 67%, p = 0.89) tumors. Analysis by Gleason score shows superior outcomes for Gleason 8-10 lesions treated with EBRT vs. BT (5-year FFS 52% vs. 28%, p = 0.04); outcomes for lower grade lesions (Gleason 4-6) when analyzed by Gleason score alone do not significantly differ according to treatment received. Patients with initial PSA values of 10-20 ng/dL have an improved FFS with EBRT vs. BT at 5 years (70% vs. 53%, p = 0.001); outcomes for patients with initial PSA ranges of 0-4 ng/dL, of > 4-10 ng/dL, and > 20 ng/dL did not differ significantly by treatment received. FFS was also determined for presenting

  9. Stage-adjusted chemoradiation in cervical cancer after transperitoneal laparoscopic staging

    Energy Technology Data Exchange (ETDEWEB)

    Marnitz, S.; Bischoff, A.; Budach, V. [Charite Berlin (Germany). Dept. of Radiooncology; Koehler, C.; Roth, C.; Schneider, A. [Charite Berlin (Germany). Dept. of Gynecology; Fueller, J.; Wendt, T. [Jena Univ. (Germany). Dept. of Radiooncology

    2007-09-15

    Purpose: To evaluate the impact of transperitoneal laparoscopic staging on choice of subsequent therapy including oncologic outcome and toxicity of chemoradiation after surgical staging. Patients and Methods: 101 patients with cervical cancer FIGO IB1-IVB underwent chemoradiation after transperitoneal laparoscopic staging. Results: 101 women (FIGO IB1-IVB) were laparoscopically staged. In 68/101 patients, pelvic and/or paraaortic lymph node metastases were confirmed histologically. Only 17/101 patients (17%) retained their original FIGO stage after laparoscopy. Laparoscopic staging and chemoradiation were well tolerated. Laparoscopic debulking of tumor-involved lymph nodes resulted in significantly improved overall survival. Conclusion: In patients with cervical cancer, laparoscopic staging led to an upstaging of 83% of cases with significant impact on therapeutic strategies. Nodal debulking prior to chemoradiation improves the prognosis of node positive women. Pretherapeutic laparoscopic staging should be the basis of the primary chemoradiation in patients with cervical cancer. (orig.)

  10. Challenges in optimizing chemoradiation in locally advanced non small-cell lung cancers in India

    Directory of Open Access Journals (Sweden)

    Sushma Agrawal

    2013-01-01

    Full Text Available Data supporting use of concurrent chemoradiation in locally advanced lung cancers comes from clinical trials from developed countries. Applicability and outcomes of such schedules in developing countries is not widely reported. There are various challenges in delivering chemoradiation in locally advanced non small cell lung cancer in developing countries which is highlighted by an audit of patients treated with chemoradiation in our center. This article deals with the challenges in the context of a developing country. We conclude that sequential chemoradiotherapy is better tolerated than concurrent chemoradiation in Indian patients with locally advanced non-small cell lung cancers. Patients with stage IIIa, normal weight or overweight, and adequate baseline pulmonary function should be offered concurrent chemoradiation.

  11. Dose volume histogram analysis of normal structures associated with accelerated partial breast irradiation delivered by high dose rate brachytherapy and comparison with whole breast external beam radiotherapy fields

    Directory of Open Access Journals (Sweden)

    Mutyala Subhakar

    2008-11-01

    Full Text Available Abstract Purpose To assess the radiation dose delivered to the heart and ipsilateral lung during accelerated partial breast brachytherapy using a MammoSite™ applicator and compare to those produced by whole breast external beam radiotherapy (WBRT. Materials and methods Dosimetric analysis was conducted on patients receiving MammoSite breast brachytherapy following conservative surgery for invasive ductal carcinoma. Cardiac dose was evaluated for patients with left breast tumors with a CT scan encompassing the entire heart. Lung dose was evaluated for patients in whom the entire lung was scanned. The prescription dose of 3400 cGy was 1 cm from the balloon surface. MammoSite dosimetry was compared to simulated WBRT fields with and without radiobiological correction for the effects of dose and fractionation. Dose parameters such as the volume of the structure receiving 10 Gy or more (V10 and the dose received by 20 cc of the structure (D20, were calculated as well as the maximum and mean doses received. Results Fifteen patients were studied, five had complete lung data and six had left-sided tumors with complete cardiac data. Ipsilateral lung volumes ranged from 925–1380 cc. Cardiac volumes ranged from 337–551 cc. MammoSite resulted in a significantly lower percentage lung V30 and lung and cardiac V20 than the WBRT fields, with and without radiobiological correction. Conclusion This study gives low values for incidental radiation received by the heart and ipsilateral lung using the MammoSite applicator. The volume of heart and lung irradiated to clinically significant levels was significantly lower with the MammoSite applicator than using simulated WBRT fields of the same CT data sets. Trial registration Dana Farber Trial Registry number 03-179

  12. Improved outcome of131I-mIBG treatment through combination with external beam radiotherapy in the SK-N-SH mouse model of neuroblastoma.

    Science.gov (United States)

    Corroyer-Dulmont, Aurélien; Falzone, Nadia; Kersemans, Veerle; Thompson, James; Allen, Danny P; Able, Sarah; Kartsonaki, Christiana; Malcolm, Javian; Kinchesh, Paul; Hill, Mark A; Vojnovic, Boris; Smart, Sean C; Gaze, Mark N; Vallis, Katherine A

    2017-09-01

    To assess the efficacy of different schedules for combining external beam radiotherapy (EBRT) with molecular radiotherapy (MRT) using 131 I-mIBG in the management of neuroblastoma. BALB/c nu/nu mice bearing SK-N-SH neuroblastoma xenografts were assigned to five treatment groups: 131 I-mIBG 24h after EBRT, EBRT 6days after 131 I-mIBG, EBRT alone, 131 I-mIBG alone and control (untreated). A total of 56 mice were assigned to 3 studies. Study 1: Vessel permeability was evaluated using dynamic contrast-enhanced (DCE)-MRI (n=3). Study 2: Tumour uptake of 131 I-mIBG in excised lesions was evaluated by γ-counting and autoradiography (n=28). Study 3: Tumour volume was assessed by longitudinal MR imaging and survival was analysed (n=25). Tumour dosimetry was performed using Monte Carlo simulations of absorbed fractions with the radiation transport code PENELOPE. Given alone, both 131 I-mIBG and EBRT resulted in a seven-day delay in tumour regrowth. Following EBRT, vessel permeability was evaluated by DCE-MRI and showed an increase at 24h post irradiation that correlated with an increase in 131 I-mIBG tumour uptake, absorbed dose and overall survival in the case of combined treatment. Similarly, EBRT administered seven days after MRT to coincide with tumour regrowth, significantly decreased the tumour volume and increased overall survival. This study demonstrates that combining EBRT and MRT has an enhanced therapeutic effect and emphasizes the importance of treatment scheduling according to pathophysiological criteria such as tumour vessel permeability and tumour growth kinetics. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Dose-modeling study to compare external beam techniques from protocol NSABP B-39/RTOG 0413 for patients with highly unfavorable cardiac anatomy

    International Nuclear Information System (INIS)

    Hiatt, Jessica R.; Evans, Suzanne B.; Price, Lori Lyn; Cardarelli, Gene A.; Di Petrillo, Thomas A.; Wazer, David E.

    2006-01-01

    Purpose: The aim of this study was to select patients with heart anatomy that is specifically unfavorable for tangential irradiation in whole-breast radiotherapy (WBRT), to be used as an experimental cohort to compare cardiac dosimetric and radiobiological parameters of three-dimensional conformal external beam accelerated partial breast irradiation (3D-CRT APBI) to WBRT with techniques as defined by the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 clinical trial. Methods and Materials: A dosimetric modeling study that compared WBRT and 3D-CRT APBI was performed on CT planning data from 8 patients with left-sided breast cancer. Highly unfavorable cardiac anatomy was defined by the measured contact of the myocardium with the anterior chest wall in the axial and para-sagittal planes. Treatment plans of WBRT and 3D-CRT APBI were generated for each patient in accordance with NSABP B-39/RTOG 0413 protocol. Dose-volume relationships of the heart, including the V 5 min (minimum dose delivered to 5% of the cardiac volume), biological effective dose (BED) of the V 5 min, and normal tissue complication probability (NTCP) were analyzed and compared. Results: Despite expected anatomic variation, significantly large differences were found favoring 3D-CRT APBI in cumulative dose-volume histograms (p 5 min (mean difference, 24.53 Gy; p 5 min (85%, p < 0.01). Conclusions: Use of 3D-CRT APBI can demonstrate improved sparing of the heart in select patients with highly unfavorable cardiac anatomy for WBRT, and may result in reduced risk of cardiac morbidity and mortality

  14. A Study on Stereoscopic X-ray Imaging Data Set on the Accuracy of Real-Time Tumor Tracking in External Beam Radiotherapy

    Science.gov (United States)

    Ghorbanzadeh, Leila

    2016-01-01

    At external beam radiotherapy, stereoscopic X-ray imaging system is responsible as tumor motion information provider. This system takes X-ray images intermittently from tumor position (1) at pretreatment step to provide training data set for model construction and (2) during treatment to control the accuracy of correlation model performance. In this work, we investigated the effect of imaging data points provided by this system on treatment quality. Because some information is still lacking about (1) the number of imaging data points, (2) shooting time for capturing each data point, and also (3) additional imaging dose delivered by this system. These 3 issues were comprehensively assessed at (1) pretreatment step while training data set is gathered for prediction model construction and (2) during treatment while model is tested and reconstructed using new arrival data points. A group of real patients treated with CyberKnife Synchrony module was chosen in this work, and an adaptive neuro-fuzzy inference system was considered as consistent correlation model. Results show that a proper model can be constructed while the number of imaging data points is highly enough to represent a good pattern of breathing cycles. Moreover, a trade-off between the number of imaging data points and additional imaging dose is considered in this study. Since breathing phenomena are highly variable at different patients, the time for taking some of imaging data points is very important, while their absence at that critical time may yield wrong tumor tracking. In contrast, the sensitivity of another category of imaging data points is not high, while breathing is normal and in the control range. Therefore, an adaptive supervision on the implementation of stereoscopic X-ray imaging is proposed to intelligently accomplish shooting process, based on breathing motion variations. PMID:27037300

  15. Dose painting to treat single-lobe prostate cancer with hypofractionated high-dose radiation using targeted external beam radiation: Is it feasible?

    International Nuclear Information System (INIS)

    Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.; Ryan, Nicole; Raben, David

    2015-01-01

    Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involved lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V 70 (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V 70 was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB

  16. Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated E