WorldWideScience

Sample records for extended hepatic grafts

  1. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  2. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  3. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  4. Impact of Short Hepatic Vein Reconstruction in Living Donor Adult Liver Transplantation Using a Left Liver Plus Caudate Lobe Graft

    Directory of Open Access Journals (Sweden)

    Koji Mikami

    2010-01-01

    Conclusion: Although no definite advantage from the V1 reconstruction was demonstrated, hepatic vein reconstruction with a significantly-sized short hepatic vein might provide an additional margin of safety for marginally-sized liver grafts during the early phase of graft regeneration.

  5. Hepatic blood flow distribution and performance in conventional and novel Y-graft Fontan geometries: a case series computational fluid dynamics study.

    Science.gov (United States)

    Yang, Weiguang; Vignon-Clementel, Irene E; Troianowski, Guillaume; Reddy, V Mohan; Feinstein, Jeffrey A; Marsden, Alison L

    2012-05-01

    A novel Y-shaped baffle has been proposed for the Fontan operation with promising initial results. However, previous studies have relied either on idealized models or a single patient-specific model. The objective of this study is to comprehensively compare the hemodynamic performance and hepatic blood flow distribution of the Y-graft Fontan baffle with 2 current designs using multiple patient-specific models. Y-shaped and tube-shaped grafts were virtually implanted into 5 patient-specific Glenn models forming 3 types of Fontan geometries: Y-graft, T-junction, and offset. Unsteady flow simulations were performed at rest and at varying exercise conditions. The hepatic flow distribution between the right and left lungs was carefully quantified using a particle tracking method. Other physiologically relevant parameters such as energy dissipation, superior vena cava pressure, and wall shear stress were evaluated. The Fontan geometry significantly influences the hepatic flow distribution. The Y-graft design improves the hepatic flow distribution effectively in 4 of 5 patients, whereas the T-junction and offset designs may skew as much as 97% of hepatic flow to 1 lung in 2 cases. Sensitivity studies show that changes in pulmonary flow split can affect the hepatic flow distribution dramatically but that some Y-graft and T-junction designs are relatively less sensitive than offset designs. The Y-graft design offers moderate improvements over the traditional designs in power loss and superior vena cava pressure in all patients. The Y-graft Fontan design achieves overall superior hemodynamic performance compared with traditional designs. However, the results emphasize that no one-size-fits-all solution is available that will universally benefit all patients and that designs should be customized for individual patients before clinical application. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. One-step reconstruction of the right inferior hepatic veins using auto-venous grafts in living-donor liver transplantation.

    Science.gov (United States)

    Ikegami, Toru; Shirabe, Ken; Yoshiya, Shohei; Soejima, Yuji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Toshima, Takeo; Motomura, Takashi; Maehara, Yoshihiko

    2013-07-01

    Reconstruction of the right inferior hepatic vein (RIHV) presents a major technical challenge in living donor liver transplantation (LDLT) using right lobe grafts. We studied 47 right lobe LDLT grafts with RIHV revascularization, comparing one-step reconstruction, performed post-May 2007 (n = 16), with direct anastomosis, performed pre-May 2007 (n = 31). In the one-step reconstruction technique, the internal jugular vein (n = 6), explanted portal vein (n = 5), inferior vena cava (n = 3), and shunt vessels (n = 2) were used as venous patch grafts for unifying the right hepatic vein, RIHVs, and middle hepatic vein tributaries. By 6 months after LDLT, there was no case of occlusion of the reconstructed RIHVs in the one-step reconstruction group, but a cumulative occlusion rate of 18.2 % in the direct anastomosis group. One-step reconstruction required a longer cold ischemic time (182 ± 40 vs. 115 ± 63, p one-step reconstruction and 83.9 % with direct anastomosis, respectively. One-step reconstruction of the RIHVs using auto-venous grafts is an easy and feasible technique promoting successful right lobe LDLT.

  7. Calculation of portal contribution to hepatic blood flow with 99mTc-microcolloids. A noninvasive method to diagnose liver graft rejection

    International Nuclear Information System (INIS)

    Martin-Comin, J.; Mora, J.; Figueras, J.; Puchal, R.; Jaurrieta, E.; Badosa, F.; Ramos, M.

    1988-01-01

    The portal contribution (PC) to hepatic blood flow was calculated in 13 liver graft patients and 13 normal volunteers. The method is based on the quantification and normalization of the liver and spleen activity after the administration of 7 mCi (259 MBq) of 99mTc microcolloid. Forty examinations were performed in liver grafts and 13 in normal subjects. The PC was significantly higher in normal native liver (64.0 +/- 3.0%) than in functioning grafts (58.8 +/- 3.1%). In acutely rejecting patients, PC was significantly lower (52.4 +/- 2.0%) than in functioning grafts and similar to that observed in cholangitis (53.5 +/- 0.7%). The PC increases again once rejection has resolved (57.3 +/- 2.6%). During hepatitis post-transplant PC values (59.7 +/- 3.4%) were similar to those observed in functioning grafts. Overall, PC values over 55% are very unlikely to be due to rejection

  8. Simultaneous nephrectomy and coronary artery bypass grafting through extended sternotomy

    Directory of Open Access Journals (Sweden)

    Budrikis Algimantas

    2012-08-01

    Full Text Available Abstract Background The advances in surgical techniques, resuscitation and anesthesiology support over the last years have allowed simultaneous thoracic and abdominal operations to be made for cancer and concomitant severe heart vessel disease relieving the patient from several diseases simultaneously and achieving long lasting remission or cure. Clinical case A simultaneous nephrectomy and coronary artery bypass grafting procedure through extended sternotomy is reported. A 63-year-old man with severe coronary artery disease was found to have renal carcinoma. Diagnosis Postoperative pathological investigation of the tumor revealed the presence of renal cell carcinoma pT3a N0 M0, G2. Coronarography revealed advanced three-vessel coronary artery disease. Treatment We successfully performed a simultaneous curative surgery for renal carcinoma and coronary artery bypass graft surgery under cardiopulmonary bypass using a novel technique of extended sternotomy. Simultaneous surgery thus appears to be a beneficial and safe approach for the treatment of coronary artery disease and resectable renal cancer in carefully selected patients.

  9. Accuracy of the CT-estimated weight of the right hepatic lobe prior to living related liver donation (LRLD) for predicting the intraoperatively measured weight of the graft

    International Nuclear Information System (INIS)

    Lemke, A.-J.; Brinkmann, M.; Felix, R.; Pascher, A.; Steinmueller, T.; Settmacher, U.; Neuhaus, P.

    2003-01-01

    Purpose: Due to the shortage of cadaver donors, living related liver donation (LRLD) has emerged as an alternative to cadaver donation. The expected graft weight is one of the main determinants for donor selection. This study investigates the accuracy of preoperatively performed CT-volumetry to predict the actual weight of the right liver lobe graft. Materials and methods: In a prospective study the weight of the right hepatic lobe was calculated by volumetric analysis based on CT in 33 patients (21 females, 12 males, mean age 42.1 years, median age 41 years) prior to living related liver donation. Graft weight was calculated as the product of CT-based graft volume and 1.00 g/ml (the approximated density of healthy liver parenchyma). The calculated weight was compared with the intraoperatively measured weight of the harvested right hepatic lobe. The difference was used to determine a correction factor for estimating the actual graft weight. Results: Based on the assumption of a parenchymal density of 1.00 g/ml, the preoperatively estimated graft weight (mean 980 g ± 168 g) deviated + 33% from the intraoperatively measured right hepatic lobe weight (mean 749 g ± 170 g). By reducing the preoperatively predicted weight of the right hepatic lobe with a correction factor of 0.75, the actual graft weight can be calculated [de

  10. [Hepatitis B infection transmission by anti-HBc-positive grafts].

    Science.gov (United States)

    Bárcena, Rafael

    2014-07-01

    In Spain, the rate of anti-HBc positive, HBsAg-negative carriers is approximately 10% of adults between the ages of 26 and 65 years. It is therefore impossible to exclude these donors without increasing the mortality of recipients on waiting lists. The incidence of de novo hepatitis B infection in HBsAg-negative recipients of anti-HBc-positive donors is high without prophylaxis and is related to the serological state of the recipient against HBV. Anti-HBc and anti-HBs-positive recipients have low risk, with or without prophylaxis. This patient group therefore does not require prophylaxis but rather periodic posttransplantation checkups. For the other recipient groups (naïve, anti-Hbc and anti-HBs isolates), prophylaxis with IgG HB, lamivudine or combined therapy decreases the incidence of infection. These patients should be treated with prophylaxis immediately after transplantation. Depending on the risk, cost and benefit, patients should currently be treated with lamivudine 100mg/d indefinitely or for longer periods (>10 years). Periodic checkups of HBsAg should be conducted, and if there is graft dysfunction then HBV DNA should be checked. IF HBV DNA is discovered in the donor and found to be positive in serum or in the biopsy, the prophylaxis should be an analogue with a high barrier to resistance from the start. Grafts from anti-HBc-positive donors are not considered at-risk grafts and are used according to donor severity, without being determined by the recipient's serological profile. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  11. [Ischemic cholangiopathy induced by extended burns].

    Science.gov (United States)

    Cohen, Laurence; Angot, Emilie; Goria, Odile; Koning, Edith; François, Arnaud; Sabourin, Jean-Christophe

    2013-04-01

    Ischemic cholangiopathy is a recently described entity occurring mainly after hepatic grafts. Very few cases after intensive care unit (ICU) for extended burn injury were reported. We report the case of a 73-year-old woman consulting in an hepatology unit, for a jaundice appearing during a hospitalisation in an intensive care unit and increasing from her leaving from ICU, where she was treated for an extended burn injury. She had no pre-existing biological features of biliary disease. Biological tests were normal. Magnetic resonance imaging acquisitions of biliary tracts pointed out severe stenosing lesions of diffuse cholangiopathy concerning intrahepatic biliary tract, mainly peri-hilar. Biopsie from the liver confirmed the diagnosis, showing a biliary cirrhosis with bile infarcts. This case is the fourth case of ischemic cholangiopathy after extended burn injury, concerning a patient without a prior history of hepatic or biliary illness and appearing after hospitalisation in intensive care unit. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  12. A retrospective 15-year review: survival advantage after switching to sirolimus in hepatitis C virus infected liver graft recipients.

    Science.gov (United States)

    Shah, M; Shankar, A; Gee, I; Nash, K; Hoare, M; Gibbs, P; Davies, S; Alexander, G J M

    2015-02-01

    The use of sirolimus-based immune suppression in liver transplantation, particularly in hepatitis C virus (HCV)-infected recipients, remains contentious. There is some evidence that sirolimus retards hepatic fibrosis, is renal sparing and may be of benefit in preventing hepatocellular carcinoma (HCC) recurrence. Sirolimus has not been adopted by many transplant centres because of persistent concerns regarding an increased risk of hepatic artery thrombosis, graft loss and death with de novo sirolimus. To review the impact of switching to sirolimus monotherapy in HCV-infected liver recipients with respect to survival, graft loss and hepatic fibrosis. A retrospective review of 190 patients from a single centre undergoing first liver transplantation for HCV over 15 years. 113 patients were switched from calcineurin inhibitor (CNI)-based therapy to low-dose sirolimus monotherapy at a median of 15 months after transplantation for HCV-related fibrosis (72%), renal impairment (14%) or high-risk HCC (5%). Patients switched to sirolimus had improved survival (P diabetes (P = 0.03). These data suggest selective switching to low-dose sirolimus monotherapy in HCV-positive liver recipients improves clinical outcome. © 2014 John Wiley & Sons Ltd.

  13. Simplified one-orifice venoplasty for middle hepatic vein reconstruction in adult living donor liver transplantation using right lobe grafts.

    Science.gov (United States)

    Kim, Joo Dong; Choi, Dong Lak; Han, Young Seok

    2014-05-01

    Middle hepatic vein (MHV) reconstruction is often essential to avoid hepatic congestion and serious graft dysfunction in living donor liver transplantation (LDLT). The aim of this report was to introduce evolution of our MHV reconstruction technique and excellent outcomes of simplified one-orifice venoplasty. We compared clinical outcomes with two reconstruction techniques through retrospective review of 95 recipients who underwent LDLT using right lobe grafts at our institution from January 2008 to April 2012; group 1 received separate outflow reconstruction and group 2 received new one-orifice technique. The early patency rates of MHV in group 2 were higher than those in group 1; 98.4% vs. 88.2% on postoperative day 7 (p = 0.054) and 96.7% vs. 82.4% on postoperative day 14, respectively (p = 0.023). Right hepatic vein (RHV) stenosis developed in three cases in group 1, but no RHV stenosis developed because we adopted one-orifice technique (p = 0.043). The levels of aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in group 2 were significantly lower than those in group 1 during the early post-transplant period. In conclusion, our simplified one-orifice venoplasty technique could secure venous outflow and improve graft function during right lobe LDLT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Bone graft extenders and substitutes in the thoracolumbar spine.

    Science.gov (United States)

    Arner, Justin W; Daffner, Scott D

    2012-05-01

    Autologous iliac crest bone graft remains the gold standard for lumbar fusion. The potential for complications has led to the development of alternative bone graft materials and enhancers, including autologous growth factors, demineralized bone matrix products, osteoinductive agents, and ceramic products. The current literature centers mainly on preclinical studies, which, further complicating the situation, evaluate these products in different clinical scenarios or surgical techniques. Autologous growth factors and demineralized bone matrix products have had promising results in preclinical studies, but few strong clinical studies have been conducted. Ceramic extenders were evaluated with other substances and had good but often inconsistent results. Bone morphogenetic proteins have been extensively studied and may have benefits as osteoinductive agents. Category comparisons are difficult to make, and there are differences even between products within the same category. The surgeon must be knowledgeable about products and their advantages, disadvantages, indications, contraindications, and possible applications so that they can make the best choice for each patient.

  15. Successful treatment of an iatrogenic hepatic arteriobiliary fistula with an endobiliary covered stent graft: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyun; Lee, Su Lim; Ku, Young Mi; Chun, Chang Woo [The Catholic Univ. of Korea, Uijeongbu (Korea, Republic of)

    2012-07-15

    Hepatic arteriobiliary fistula is a rare cause of hemobilia following percutaneous transhepatic biliary drainage for treatment of hilar cholangiocarcinoma. Hemobilia related to arterial injury is resistant to conservative treatment. Therefore, transarterial embolization after confirmation of bleeding vessels on an angiogram is generally considered as the first line of treatment to stop arterial bleeding. However, in high risk situations such as a hepatic infarction by arterial embolization, the endobiliary approach with a covered stent can be considered as an alternative treatment method. The authors report a case of iatrogenic arteriobiliary fistula in a patient with hilar cholangiocarcinoma which was successfully controlled by an endobiliary covered stent graft.

  16. [Effect of nutritional status of the donor on the quality of hepatic graft. Value of restoration of glycogenic reserves of the donor].

    Science.gov (United States)

    Pattou, F; Boudjema, K; Kerr-Conte, J; Wolf, P; Jaeck, D; Cinqualbre, J

    1992-01-01

    Initial function of the graft is an essential factor for successful liver transplantation. The aim of this study was to evaluate the influence of the nutritional status of the donor on hepatic graft quality at reperfusion. Livers (n = 41) were taken from pigs normally fed or fasted for 24 h or fasted for 24 h and conditioned for 2 hours with a solution containing glucose, fructose and glutamine. The quality of liver grafts was evaluated using an original, blood-free isolated perfusion model, after 8 h cold storage, or after 15 min warm ischemia performed prior to harvesting. The hepatic concentration of glycogen and ATP, measured from in vivo biopsies, was decreased in fasted animals (P less than 0.05 vs fed) and restored by nutritional conditioning (P less than 0.05 vs fasted). At the time of reperfusion following 8 h cold ischemia, the liberation of aminotransferases and lactate dehydrogenase was elevated in livers coming from fasted animals (P less than 0.05 vs fed) and restored to fed levels after nutritional conditioning (P less than 0.01 vs fasted). After 15 min of warm ischemia, the bile secretion during the reperfusion period was decreased in the 24 h fasted livers (P less than 0.01 vs fed) and reestablished after nutritional conditioning (P less than 0.01 vs fasted). Perfusion of the donor liver, in the 2 h preceding harvest, with a solution of glucose plus neoglucogenic precursors enhances the quality of the liver graft at the time of reperfusion.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. PTFE Graft as a "Bridge" to Communicating Veins Maturation in the Treatment of an Intrahepatic Cholangiocarcinoma Involving the 3 Hepatic Veins. The Minor-but-Complex Liver Resection.

    Science.gov (United States)

    Urbani, Lucio; Balestri, Riccardo; Sidoti, Francesco; Bernardini, Juri Riccardo; Arces, Francesco; Licitra, Gabriella; Leoni, Chiara; Forfori, Francesco; Colombatto, Piero; Boraschi, Piero; Castagna, Maura; Buccianti, Piero

    2016-12-01

    Parenchyma-sparing liver surgery allows resecting hepatic veins (HV) at the hepatocaval confluence with minor (PTFE graft can be used as a bridge to communicating-veins maturation to ensure the correct outflow of the spared liver. We present a video of an intrahepatic cholangiocarcinoma (IC) involving the three HV at the hepatocaval confluence treated with this approach. In a 50-year old obese (BMI 44.8) male a 6-cm IC involving the hepatocaval confluence was identified during the follow-up for a kidney malignancy. At the preoperative CT scan the left HV was not detectable, the middle HV was incorporated within the tumor, and right HV had a 3-cm contact with the tumor. No communicating veins were evident at preoperative imaging. After a J-shape thoracophrenolaparotomy, the resection of segments II-III-IVa was partially extended to segment VIII-VII and I. The right HV was detached from the tumor, and the middle HV was reconstructed with a 7-mm ringed-armed PTFE graft anastomosed to V8. Surgery lasted 20 h and 55 min with an estimated blood loss of 3500 ml, but the postoperative course was uneventful and the patient was discharged on the 14th postoperative day. One month later the CT scan showed a patent PTFE graft with the maturation of communicating-veins. One year later a complete thrombosis of the PTFE graft was observed with normal liver perfusion and function, and the patient was disease-free. PTFE-based parenchyma-sparing liver resection is a new tool to treat tumors located at the hepatocaval confluence exploiting the maturation of intrahepatic communicating-veins between main HV.

  18. Early Introduction of Everolimus Immunosuppressive Regimen in Liver Transplantation with Extra-Anatomic Aortoiliac-Hepatic Arterial Graft Anastomosis

    Directory of Open Access Journals (Sweden)

    Emanuele Felli

    2014-01-01

    Full Text Available Liver transplantation is the treatment of choice for patients with acute and chronic end-stage liver disease, when no other medical treatment is possible. Despite high rates of 1- to 5-year survival, long-term adverse effects of immunosuppressant agents remain of major concern. Current research and clinical efforts are made to develop immunosuppressant agents that minimize adverse effects along with a low rate of graft rejection. Tailoring immunosuppressive therapy to individual patients by the use of proliferation signal inhibitors seems to be the best way to minimize toxicity and increase efficacy. Recently everolimus has been introduced in clinical practice; among its adverse effects an increased incidence of arterial graft thrombosis in renal transplants, vascular anastomosis leakage, impaired wound healing, and thrombotic microangiopathy have been reported. We present the case of a 54-year-old patient submitted to liver transplantation for end-stage liver disease treated by an extra-anatomic aortoiliac-hepatic arterial graft anastomosis and early postoperative introduction of everolimus for acute renal failure. Postoperative period was characterized by two abdominal collections and reactivation of cytomegalovirus infection that were treated by percutaneous drainage and antiviral therapy, respectively; the patient is well after 8-month followup with patency of the arterial conduit and no leakage.

  19. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  20. The Impact of Liver Graft Injury on Cancer Recurrence Posttransplantation.

    Science.gov (United States)

    Li, Chang-Xian; Man, Kwan; Lo, Chung-Mau

    2017-11-01

    Liver transplantation is the most effective treatment for selected patients with hepatocellular carcinoma. However, cancer recurrence, posttransplantation, remains to be the critical issue that affects the long-term outcome of hepatocellular carcinoma recipients. In addition to tumor biology itself, increasing evidence demonstrates that acute-phase liver graft injury is a result of hepatic ischemia reperfusion injury (which is an inevitable consequence during liver transplantation) and may promote cancer recurrence at late phase posttransplantation. The liver grafts from living donors, donors after cardiac death, and steatotic donors have been considered as promising sources of organs for liver transplantation and are associated with high incidence of liver graft injury. The acute-phase liver graft injury will trigger a series of inflammatory cascades, which may not only activate the cell signaling pathways regulating the tumor cell invasion and migration but also mobilize the circulating progenitor and immune cells to facilitate tumor recurrence and metastasis. The injured liver graft may also provide the favorable microenvironment for tumor cell growth, migration, and invasion through the disturbance of microcirculatory barrier function, induction of hypoxia and angiogenesis. This review aims to summarize the latest findings about the role and mechanisms of liver graft injury resulted from hepatic ischemia reperfusion injury on tumor recurrence posttransplantation, both in clinical and animal cohorts.

  1. Within patient radiological comparative analysis of the performance of two bone graft extenders utilized in posterolateral lumbar fusion: a retrospective case series

    Directory of Open Access Journals (Sweden)

    Geoffrey eStewart

    2016-01-01

    Full Text Available Two bone graft extenders differing in chemical composition were implanted contralaterally in 27 consecutive patients undergoing instrumented posterolateral lumbar fusion as standard of care. Bone marrow aspirate and autogenous bone graft were equally combined either with β-tricalcium phosphate (β-TCP or a hybrid biomaterial (containing hyaluronic acid but lacking a calcium salt and implanted between the transverse processes. Fusion status on each side of the vertebrae was retrospectively graded (1-5 scale on AP planar X-ray at multiple visits as available, through approximately month 12. Additionally, consolidation or resorption since prior visit for each treatment was recorded. Sides receiving β-TCP extender showed marked resorption prior to bone consolidation during the first 6 months. By contrast, sides receiving the hybrid biomaterial containing integrated hyaluronic acid showed rapid bone consolidation by week 6-8, with maintenance of initial bone volume through month 12. Fusion grade was superior for the hybrid biomaterial, differing significantly from β-TCP at day 109 and beyond. Fusion success at >month 12 was 92.9% vs 67.9% for the hybrid biomaterial and β-TCP-treated sides, respectively. The hybrid biomaterial extender demonstrated a shortened time to fusion compared to the calcium-based graft. Mode of action has been demonstrated in the literature to differ between these compositions. Therefore, choice of synthetic biomaterial composition may significantly influence mode of action of cellular events regulating appositional bone growth.

  2. Brucellosis With Multi-Organ Involvement in a Patient With History of Composite Aortic Graft and Hepatitis B.

    Science.gov (United States)

    Dehghan Manshadi, Seyed Ali; Rezahosseini, Omid; Abdi Liaei, Zahra

    2016-11-01

    The brucellosis with multi-organ involvement in a patient with a history of the composite aortic graft (Bentall procedure) and Hepatitis B infection is rare. A 35-year-old man presented to us with fever and loss of consciousness. Four years ago, he was IDU and underwent cardiac surgery because of endocarditis. Recently lumbar spondylodiscitis was diagnosed. The Wright (1/320) and Coombs Wright tests (1/640) were positive. After CNS imaging, lumbar puncture was done. The CSF pleocytosis was lymphocyte dominant. In cardiac echocardiography, large vegetation on prosthetic aortic valve leaflets was seen. The brain MRI was reported abnormal. Treatment of brucellosis started with Ceftriaxone, Doxycycline, Rifampin and Gentamycin. After 4 days, he became oriented, and fever was disappeared then we continued the treatment for 16 days. The patient discharged and followed by daily phone calls. As symptoms of abdominal pain and jaundice were presented on the fifth day, he re-admitted. The patient expired because of hepatorenal and cardiac insufficiency. Drug side effects, activation of Hepatitis B and embolism of cardiac vegetation to other organs were suspected causes of death. We do not suggest medical therapy without cardiac surgery in such cases. When combination therapy is necessary for brucellosis in an HBsAg-positive patient, hepatitis virus activity should be assess by HBV-DNA PCR and the dose of drugs with known hepatotoxic effects such as rifampin and co-trimoxazole should be adjust. Combination therapy with quinolones instead of hepatoxic drugs is one of our suggustions.

  3. Fluorescence spectroscopy for assessment of liver transplantation grafts concerning graft viability and patient survival

    Science.gov (United States)

    Vollet Filho, José D.; da Silveira, Marina R.; Castro-e-Silva, Orlando; Bagnato, Vanderlei S.; Kurachi, Cristina

    2015-06-01

    Evaluating transplantation grafts at harvest is essential for its success. Laser-induced fluorescence spectroscopy (LIFS) can help monitoring changes in metabolic/structural conditions of tissue during transplantation. The aim of the present study is to correlate LIFSobtained spectra of human hepatic grafts during liver transplantation with post-operative patients' mortality rate and biochemical parameters, establishing a method to exclude nonviable grafts before implantation. Orthotopic liver transplantation, piggyback technique was performed in 15 patients. LIFS was performed under 408nm excitation. Collection was performed immediately after opening donor's abdominal cavity, after cold perfusion, end of back-table period, and 5 min and 1 h after warm perfusion at recipient. Fluorescence information was compared to lactate, creatinine, bilirubin and INR levels and to survival status. LIFS was sensitive to liver changes during transplantation stages. Study-in-progress; initial results indicate correlation between fluorescence and life/death status of patients.

  4. Prospective evaluation of intraoperative hemodynamics in liver transplantation with whole, partial and DCD grafts

    NARCIS (Netherlands)

    Sainz-Barriga, M; Reyntjens, K; Costa, M G; Scudeller, L; Rogiers, X; Wouters, P; de Hemptinne, B; Troisi, R I

    The interaction of systemic hemodynamics with hepatic flows at the time of liver transplantation (LT) has not been studied in a prospective uniform way for different types of grafts. We prospectively evaluated intraoperative hemodynamics of 103 whole and partial LT. Liver graft hemodynamics were

  5. Retransplantation in Late Hepatic Artery Thrombosis: Graft Access and Transplant Outcome

    Directory of Open Access Journals (Sweden)

    Bettina M. Buchholz, MD, FEBS

    2017-08-01

    Conclusions. Inequity in graft access and peritransplant sepsis are fundamental obstacles for successful re-LT in L-HAT. Offering a graft for those in need at the best window of opportunity could facilitate earlier engrafting with improved outcomes.

  6. Chloroanthraquinone as a grafted probe molecule to investigate grafting yield on carbon powder

    International Nuclear Information System (INIS)

    Le Comte, Annaïg; Brousse, Thierry; Bélanger, Daniel

    2016-01-01

    Spontaneous grafting of chloroanthraquinone (ClAQ) groups on Black Pearls carbon by reduction of the corresponding in-situ generated diazonium cations was successfully achieved. The presence of an halogen atom on the quinone molecule allowed the use of different spectroscopic characterization techniques to determine the accurate quinone content of the modified carbon. Electrochemical characterization highlighted that the presence of chlorine atom on the grafted molecule did not affect the electrochemical response or the grafting reaction efficiency. The amount of ClAQ molecules at the carbon surface after grafting was determined by cyclic voltammetry, together with thermogravimetric analysis coupled mass spectroscopy, X-ray photoelectron spectroscopy and elemental analysis. The ClAQ mass loadings estimated from the four techniques are in very good agreement and confirm that the grafted moieties are all electrochemically active and accessible. Finally, the grafting of quinone-type molecule using the reduction of diazonium cations does not affect the electroactivity of the grafted groups and cyclic voltammetry can be considered as a reliable technique to evaluate the mass loading of grafted quinone groups on porous carbon. Thus ClAQ can be used as a grafted probe molecule to investigate grafting yield on carbon powder, and this approach can be extended to functionalized electrodes used in an increasing number of electrochemical energy storage devices.

  7. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  8. Hepatic encephalopathy in a liver transplant recipient with stable liver function.

    Science.gov (United States)

    Arab, Juan Pablo; Meneses, Luis; Pérez, Rosa M; Arrese, Marco; Benítez, Carlos

    2013-04-01

    Postshunt hepatic encephalopathy after liver transplantation (LT) is an infrequent condition and is commonly associated with portal occlusion or stenosis and the presence of a patent portosystemic shunt. Portal vein stenosis (PVS) or thrombosis (PVT) are uncommon complications after LT. The overall frequency of both complications is reported to be less than 3%. When PVS or PVT develop early after LT, the occlusion of the portal vein can have catastrophic consequences to the graft including acute liver failure and graft loss. Late PVT/PVS are asymptomatic in approximately 50% of the cases and mainly diagnosed by a routine ultrasound. Symptomatic postshunt hepatic encephalopathy (HE) is a very infrequent condition after LT that has been scarcely reported in the literature. We present here the case of a liver recipient with normal graft function who presented with hepatic encephalopathy 3 months after LT with stable liver function but a severe portal stenosis and the presence of a spontaneous portosystemic shunt whose successful endovascular treatment was followed by the complete resolution of the HE.

  9. Inducing Hepatitis C Virus Resistance After Pig Liver Transplantation-A Proof of Concept of Liver Graft Modification Using Warm Ex Vivo Perfusion.

    Science.gov (United States)

    Goldaracena, N; Spetzler, V N; Echeverri, J; Kaths, J M; Cherepanov, V; Persson, R; Hodges, M R; Janssen, H L A; Selzner, N; Grant, D R; Feld, J J; Selzner, M

    2017-04-01

    Normothermic ex vivo liver perfusion (NEVLP) offers the potential to optimize graft function prior to liver transplantation (LT). Hepatitis C virus (HCV) is dependent on the presence of miRNA(microRNA)-122. Miravirsen, a locked-nucleic acid oligonucleotide, sequesters miR-122 and inhibits HCV replication. The aim of this study was to assess the efficacy of delivering miravirsen during NEVLP to inhibit miR-122 function in a pig LT model. Pig livers were treated with miravirsen during NEVLP or cold storage (CS). Miravirsen absorption, miR-122 sequestration, and miR-122 target gene derepression were determined before and after LT. The effect of miravirsen treatment on HCV infection of hepatoma cells was also assessed. NEVLP improved miravirsen uptake versus CS. Significant miR-122 sequestration and miR-122 target gene derepression were seen with NEVLP but not with CS. In vitro data confirmed miravirsen suppression of HCV replication after established infection and prevented HCV infection with pretreatment of cells, analogous to the pretreatment of grafts in the transplant setting. In conclusion, miravirsen delivery during NEVLP is a potential strategy to prevent HCV reinfection after LT. This is the first large-animal study to provide "proof of concept" for using NEVLP to modify and optimize liver grafts for transplantation. © 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  10. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  11. Quantification of hepatic flow distribution using particle tracking for patient specific virtual Fontan surgery

    Science.gov (United States)

    Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.

  12. Graft Fibrosis After Pediatric Liver Transplantation : Ten Years of Follow-up

    NARCIS (Netherlands)

    Scheenstra, Rene; Peeters, Paul M. G. J.; Verkade, Henkjan J.; Gouw, Annette S. H.

    Previously we reported the presence of portal fibrosis in 31% (n = 84) of the grafts in protocol biopsies I year after pediatric liver transplantation (LTx). To assess the natural history of graft fibrosis after pediatric liver transplantation, we extended the analysis of graft histology in

  13. Mesh-graft urethroplasty: a case report

    OpenAIRE

    田中, 敏博; 滝川, 浩; 香川, 征; 長江, 浩朗

    1987-01-01

    We used a meshed free-foreskin transplant in a two-stage procedure for reconstruction of the extended stricture of urethra after direct vision urethrotomy. The results were excellent. Mesh-graft urethroplasty is a useful method for patients with extended strictures of the urethra or recurrent strictures after several operations.

  14. Extended normothermic extracorporeal perfusion of isolated human liver after warm ischaemia: a preliminary report.

    Science.gov (United States)

    Bellomo, Rinaldo; Marino, Bruno; Starkey, Graeme; Fink, Michael; Wang, Bao Zhong; Eastwood, Glenn M; Peck, Leah; Young, Helen; Houston, Shane; Skene, Alison; Opdam, Helen; Jones, Robert

    2014-09-01

    Donation after circulatory death (DCD) livers are at markedly increased risk of primary graft dysfunction and biliary tract ischaemia. Normothermic extracorporeal liver perfusion (NELP) may increase the ability to transplant DCD livers and may allow their use for artificial extracorporeal liver support of patients with fulminant liver failure. We conducted two proof-of-concept experiments using human livers after DCD to assess the feasibility and functional efficacy of NELP over an extended period. We applied extracorporeal membrane oxygenation, parenteral nutrition, separate hepatic artery and portal vein perfusion and physiological perfusion pressures to two livers obtained after DCD. We achieved NELP and evidence of liver function (bile production, paracetamol removal and maintenance of normal lactate levels) in both livers; one for 24 hours and the other for 43 hours. Histological examination showed areas of patchy ischaemia but preserved biliary ducts and canaliculi. Our experiments justify further investigations of the feasibility and efficacy of extended DCD liver preservation by ex-vivo perfusion.

  15. Hepatitis C Eradication and Improvement of Cryoglobulinemia-Associated Rash and Membranoproliferative Glomerulonephritis with Interferon and Ribavirin after Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Marilyn Zeman

    2006-01-01

    Full Text Available Postrenal transplant hepatitis C is increasing in frequency due to the high prevalence of hepatitis C among patients with renal failure. Despite this, there is still no standard hepatitis C treatment available for renal transplanted recipients. Combination antiviral hepatitis C therapy, the standard of care in the nontransplant population, is generally avoided because of documented renal graft rejection secondary to interferon treatment. A case of a male patient with postrenal transplant hepatitis C, which was associated with cryoglobulinemia and glomerulonephritis of the graft, is presented. He was treated with standard interferon with ribavirin. Sustained viral clearance was achieved despite ongoing evidence of cryoglobulinemia. Renal function, which had been deteriorating before treatment, improved as evidenced by the stabilization of serum creatinine and marked improvement of proteinuria. In conclusion, in selected patients, combination antiviral therapy may still be a viable option postrenal transplant.

  16. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections.

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2016-12-01

    There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012-2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3 ± 8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. © The Author(s) 2016.

  17. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  18. Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: impact on surgical procedure

    International Nuclear Information System (INIS)

    Frericks, Bernd B.J.; Kirchhoff, Timm D.; Shin, Hoen-Oh; Stamm, Georg; Merkesdal, Sonja; Abe, Takehiko; Galanski, Michael; Schenk, Andrea; Peitgen, Heinz-Otto; Klempnauer, Juergen; Nashan, Bjoern

    2006-01-01

    The purpose was to assess the volumes of the different hepatic territories and especially the drainage of the right paramedian sector in adult living donor liver transplantation (ALDLT). CT was performed in 40 potential donors of whom 28 underwent partial living donation. Data sets of all potential donors were postprocessed using dedicated software for segmentation, volumetric analysis and visualization of liver territories. During an initial period, volumes and shapes of liver parts were calculated based on the individual portal venous perfusion areas. After partial hepatic congestion occurring in three grafts, drainage territories with special regard to MHV tributaries from the right paramedian sector, and the IRHV were calculated additionally. Results were visualized three-dimensionally and compared to the intraoperative findings. Calculated graft volumes based on hepatic venous drainage and graft weights correlated significantly (r=0.86,P<0.001). Mean virtual graft volume was 930 ml and drained as follows: RHV: 680 ml, IRHV: 170 ml (n=11); segment 5 MHV tributaries: 100 ml (n=16); segment 8 MHV tributaries: 110 ml (n=20). When present, the mean aberrant venous drainage fraction of the right liver lobe was 28%. The evaluated protocol allowed a reliable calculation of the hepatic venous draining areas and led to a change in the hepatic venous reconstruction strategy at our institution. (orig.)

  19. Interventional treatment of emergent hepatic artery thrombosis after liver transplantation

    International Nuclear Information System (INIS)

    Liu Fengyong; Wang Maoqiang; Wang Zhijun; Wang Zhongpu; Shi Xianjie; Zhou Ningxin

    2006-01-01

    Objective: To evaluate the safety and efficacy of the endovascular interventional techniques for the management of emergent hepatic artery thrombosis (HAT) after orthotopic liver transplantation (OLT). Methods: Ten patients (8 men and 2 women with mean age of 47 years) diagnosed with HAT after OLT were treated with interventional procedures. All patients presented with elevation of liver enzymes and bilirubin levels. The diagnosis of the HAT was suggested by doppler ultrasonography and confirmed by angiography at 16 hours to 10 days (mean, 4.5 days) after OLT. Interventional techniques consisted of indwelling transcatheter hepatic arterial thrombolysis with a low dose of urokinase monitored under ultrasonography every 6-12 hours and stent placement in the stenotic segment of the hepatic artery was undertaken. Systemic intravenous low dose of heparin was given contemporaneously. Results: Complete occlusion of the proper HA was achieved in 10 patients. Hepatic arterial flow was re-established in 8 of the 10 patients (80%) at 12 hours to 9 days (mean, 4.8 days) after the intra-arterial thrombolysis, with significant improvement of liver function. Hepatic artery stenosis at the anastomosis was found in the 8 patients, and a stent placement in the stenotic segment was performed successfully in 7 patients with degree of stenosis over 90%.Intra-arterial thrombolysis was failed in 2 cases. Intraperitoneal hemorrhage from the anastomosis occurred in 1 patient at 12 hours after the treatment, and was emergently taken for the graft revision with reanastomosis. One patient with complete occlusion of the hepatic artery at 7 days after the treatment, but having collateral flow of the liver for maintaining liver function and thus sparing further intervention. 8 patients with successful hepatic arterial recanalization carried along a good clinical course with normal graft function at a median 12 months (range, 4 to 20 months), and patent hepatic arterial flow was identified by

  20. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  1. Hepatitis C virus infection in Saudi Arabian recipients of renal ...

    African Journals Online (AJOL)

    Background: Studies of recipients most of whom had been infected prior to transplantation, had yielded conflicting conclusions in regard to the clinical impact of hepatitis C virus [HCV] infection. We determined the frequency of new. HCV infection and assessed its effect on patient and graft survival and occurrence of chronic ...

  2. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  3. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  4. Pros and Cons: Usage of organs from donors infected with hepatitis C virus - Revision in the direct-acting antiviral era.

    Science.gov (United States)

    Coilly, Audrey; Samuel, Didier

    2016-01-01

    Should organs from hepatitis C antibody positive donors (HCVD+) be used for transplantation? Organ shortage forces transplant teams to use donors with extended criteria. The decision to transplant a HCVD+ graft is a balance between the risk of transmission of a virus that could lead to end-stage liver diseases and the benefit of access to transplantation, specifically in patients with life-threatening disease. The other issue is the impact of HCV-related liver fibrosis in the donor graft on the long-term outcome in the recipient. Thus, the use of HCVD+ demonstrated a shorter meantime on the waiting list in kidney transplantation. When a HCVD+ graft is transplanted, the risk of HCV transmission depends on; 1) the quality of screening of the donor; 2) the presence of viral replication in the donor at the time of transplantation and the ability to detect it; and 3) the HCV status of the recipient but also the type of transplanted organ. In liver transplantation, the use of HCVD+ graft is usually restricted to recipients with a chronic HCV infection. Several reports showed some competition between HCV donor and recipient strain without deleterious impact on graft and patient survival. Controversies are still pending regarding the quality of the graft and the progression of fibrosis. The recent approval of direct-acting antiviral agents (DAA) dramatically changes the landscape of HCV infection treatment. After transplantation, combinations of DAA show high efficacy and good safety profile. In the near future, extensive use of DAA should reduce the number of HCVD+ with a positive HCV RNA, limiting the risk of transmission but also the number of patients on waiting lists for a disease related to HCV. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  5. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  6. Single-Center Experience Using Marginal Liver Grafts in Korea.

    Science.gov (United States)

    Park, P-J; Yu, Y-D; Yoon, Y-I; Kim, S-R; Kim, D-S

    2018-05-01

    Liver transplantation (LT) is an established therapeutic modality for patients with end-stage liver disease. The use of marginal donors has become more common worldwide due to the sharp increase in recipients, with a consequent shortage of suitable organs. We analyzed our single-center experience over the last 8 years in LT to evaluate the outcomes of using so-called "marginal donors." We retrospectively analyzed the database of all LTs performed at our institution from 2009 to 2017. Only patients undergoing deceased-donor LTs were analyzed. Marginal grafts were defined as livers from donors >60 years of age, livers from donors with serum sodium levels >155 mEq, graft steatosis >30%, livers with cold ischemia time ≥12 hours, livers from donors who were hepatitis B or C virus positive, livers recovered from donation after cardiac death, and livers split between 2 recipients. Patients receiving marginal grafts (marginal group) were compared with patients receiving standard grafts (standard group). A total of 106 patients underwent deceased-donor LT. There were 55 patients in the standard group and 51 patients in the marginal group. There were no significant differences in terms of age, sex, Model for End-Stage Liver Disease score, underlying liver disease, presence of hepatocellular carcinoma, and hospital stay between the 2 groups. Although the incidence of acute cellular rejection, cytomegalovirus infection, and postoperative complications was similar between the 2 groups, the incidence of early allograft dysfunction was higher in the marginal group. With a median follow-up of 26 months, the 1-, 3-, and 5-year overall and graft (death-censored) survivals in the marginal group were 85.5%, 75%, and 69.2% and 85.9%, 83.6%, and 77.2%, respectively. Patient overall survival and graft survival (death-censored) were significantly lower in the marginal group (P = .023 and P = .048, respectively). On multivariate analysis, receiving a marginal graft (hazard ratio [HR

  7. Septal graft in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Bahannan, Abdulrahman; Slavicek, A.; Taudy, M.; Chovanec, M.

    2006-01-01

    A 62-year-old woman presented with symptoms of dyspnea. Ultrasonography and computed tomography examinations revealed mass extending from the cricoid cartilage to the left lobe of thyroid gland and thyroid cartilage. Cytology revealed possibility of cartilaginous origin, which was proven to be chondrosarcoma (Grade 1) from the biopsy specimen obtained during panendosopy. She underwent one stage radical resection and immediate reconstruction of laryngeal skeleton defect by mucocartilaginous graft from the nasal septum. Her postoperative course was optimal with preservation of the laryngeal functions. Twenty-eight months postoperatively, she had to undergo total laryngectomy as a salvage procedure for the advanced local recurrence. We report on the relatively easy technique for functional reconstruction of the large laryngeal defect with the employment cartilage graft from the nasal septum. (author)

  8. Grafting, pruning, and the antipodal map on measured laminations

    OpenAIRE

    Dumas, David

    2006-01-01

    Grafting a measured lamination on a hyperbolic surface defines a self-map of Teichmuller space, which is a homeomorphism by a result of Scannell and Wolf. In this paper we study the large-scale behavior of pruning, which is the inverse of grafting. Specifically, for each conformal structure $X \\in \\T(S)$, pruning $X$ gives a map $\\ML(S) \\to \\T(S)$. We show that this map extends to the Thurston compactification of $\\T(S)$, and that its boundary values are the natural antipodal involution relat...

  9. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  10. The prognosis and prognostic risk factors of patients with hepatic artery complications after liver transplantation treated with the interventional techniques

    International Nuclear Information System (INIS)

    Shan Hong; Huang Mingsheng; Jiang Zaipo; Zhu Kangshun; Yang Yang; Chen Guihua

    2008-01-01

    Objective: To investigate the prognosis and prognostic risk factors of hepatic artery complications after orthotopic liver transplantation (OLT) treated with the interventional techniques. Methods: The clinical data of 21 patients with hepatic artery complication after liver transplantation receiving thrombolysis, PTA, and stent placement in our institute from November 2003 to April 2007 were retrospectively analyzed. Based on the prognosis of grafts, 21 patients were divided into poor-prognosis group and non-poor-prognosis group. Fifteen variables (including biliary complication, hepatic artery restenosis, early or late artery complication, and so on) were analyzed in both groups with binary logistic regression analysis to screen out the risk factors related to prognosis of pereutaneous interventional treatment for hepatic artery complications after OLT. Results: Twenty-one patients were followed for mean 436 days, median 464 days (3-1037 days). The poor-prognosis group included 11 patients (5 cases received retransplantation, and 6 died). The mean survival time of grafts in poor-prognosis group was 191 days, and median survival time was 73 days (3-616 days). The mean survival time of grafts in non-poor-prognosis group which included 10 patients was 706 days, and median survival time was 692 days (245-1037 days). Univariate analysis showed there were significant difference in biliary complication, total bilimbin and indirect bilirubin between the two groups. The binary, logistic regression analysis showed the risk factor related to prognosis was with biliary complication before the interventional management (P=0.027, OR=22.818). Conclusion: Biliary complication before interventional management is the risk factor related to poor prognosis of patients with hepatic artery stenosis or thrombosis receiving interventional treatment. (authors)

  11. Prophylactic Treatment with Cerium Oxide Nanoparticles Attenuate Hepatic Ischemia Reperfusion Injury in Sprague Dawley Rats

    Directory of Open Access Journals (Sweden)

    Nandini D.P.K. Manne

    2017-07-01

    Full Text Available Background: Hepatic ischemia reperfusion is one the main causes for graft failure following transplantation. Although, the molecular events that lead to hepatic failure following ischemia reperfusion (IR are diverse and complex, previous studies have shown that excessive formation of reactive oxygen species (ROS are responsible for hepatic IR injury. Cerium oxide (CeO2 nanoparticles have been previously shown to act as an anti-oxidant and anti-inflammatory agent. Here, we evaluated the protective effects of CeO2 nanoparticles on hepatic ischemia reperfusion injury. Methods: Male Sprague Dawley rats were randomly assigned to one of the four groups: Control, CeO2 nanoparticle only, hepatic ischemia reperfusion (IR group and hepatic ischemia reperfusion (IR plus CeO2 nanoparticle group (IR+ CeO2. Partial warm hepatic ischemia was induced in left lateral and median lobes for 1h, followed by 6h of reperfusion. Animals were sacrificed after 6h of reperfusion and blood and tissue samples were collected and processed for various biochemical experiments. Results: Prophylactic treatment with CeO2 nanoparticles (0.5mg/kg i.v (IR+CeO2 group 1 hour prior to hepatic ischemia and subsequent reperfusion injury lead to a decrease in serum levels of alanine aminotransaminase and lactate dehydrogenase at 6 hours after reperfusion. These changes were accompanied by significant decrease in hepatocyte necrosis along with reduction in several serum inflammatory markers such as macrophage derived chemokine, macrophage inflammatory protein-2, KC/GRO, myoglobin and plasminogen activator inhibitor-1. However, immunoblotting demonstrated no significant changes in the levels of apoptosis related protein markers such as bax, bcl2 and caspase 3 in IR and IR+ CeO2 groups at 6 hours suggesting necrosis as the main pathway for hepatocyte death. Conclusion: Taken together, these data suggest that CeO2 nanoparticles attenuate IR induced cell death and can be used as a prophylactic

  12. Radiologic management of hepatic arterial stenosis or thrombosis following liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Suck; Sung, Kyu Bo; Lim, Soo Mee; Yoon, Hyun Ki; Song, Ho Young [Asan Medical Center, Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-06-01

    To assess the results and usefulness of interventional procedures for hepatic arterial stenosis or thrombosis following liver transplantation. During the past five years, eight patients aged 1-59 (mean, 39) years among 187 liver transplant recipients showed elevated of liver enzyme levels (AST/ALT) and decreased arterial flow at Doppler ultrasound. Hepatic arteriography revealed luminal stenosis or occlusion at the proper hepatic artery, and six patients, one of whom required thrombolysis before the procedure, underwent percutaneous transluminal angioplasty (PTA) using a balloon. In two with thrombosis, thrombolysis without PTA was performed. In order to increase hepatic arterial flow, four patients underwent additional coil embolization of the gastroduodenal or splenic artery. Hepatic arterial flow recovered in all six patients after PTA. Three required repeat PTA for restenosis and one of these needed stent placement after repeated PTA. At follow-up, 6-17 months later, the three had good hepatic function. Within four days, the other three expired due to graft failure, hepatorenal syndrome and sepsis. One of the patients who underwent thrombolysis without PTA expired and the other required retransplantation. In this case there were no procedure - related complications. Radiologic interventions are useful for treatment of hepatic arterial stensis or thrombosis in patients with liver transplantations.

  13. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  14. Evolution of skin grafting for treatment of burns: Reverdin pinch grafting to Tanner mesh grafting and beyond.

    Science.gov (United States)

    Singh, Mansher; Nuutila, Kristo; Collins, K C; Huang, Anne

    2017-09-01

    Skin grafting is the current standard care in the treatment of full thickness burns. It was first described around 1500 BC but the vast majority of advancements have been achieved over the past 200 years. An extensive literature review was conducted on Pubmed, Medline and Google Scholar researching the evolution of skin grafting techniques. The authors concentrated on the major landmarks of skin grafting and also provide an overview of ongoing research efforts in this field. The major innovations of skin grafting include Reverdin pinch grafting, Ollier grafting, Thiersch grafting, Wolfe grafting, Padgett dermatome and modifications, Meek-wall microdermatome and Tanner mesh grafting. A brief description of the usage, advantages and limitations of each technique is included in the manuscript. Skin grafting technique have evolved significantly over past 200 years from Reverdin pinch grafting to modern day meshed skin grafts using powered dermatome. Increasing the expansion ratio and improving the cosmetic and functional outcome are the main focus of ongoing skin grafting research and emerging techniques (such as Integra ® , Recell ® , Xpansion ® ) are showing promise. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  15. Revascularization of femoral head ischemic necrosis with vascularized bone graft: A CT scan experimental study

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Knapp, K.; Gomez Castresana, F.; Benito, M.

    1990-01-01

    An ischemic necrosis of the femoral head was induced in 15 mongrel adult dogs using the technique described by Gartsman et al. Five weeks later, a free vascularized rib graft was transferred into the previously induced ischemic femoral head. High resolution computed tomographic scanning was used to evaluate revascularization 4, 8 and 12 weeks after grafting. The femoral head exhibited new vessel formation throughout the study. Arterial terminal branches arising from the rib graft medullary and periosteal circulations extended beyond the rib graft, entered the head, and reached the subchondral plate. Even where the rib graft did not replenish the central core of the head, there was vascular supply from the grafted bone's vascular tree. These results suggest that a free vascularized bone graft is able to revascularize an experimentally induced ischemic femoral head necrosis. (orig.)

  16. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  17. [Oral mucosa graft urethroplasty for complicated urethral strictures].

    Science.gov (United States)

    Horiguchi, Akio; Sumitomo, Makoto; Kanbara, Taiki; Tsujita, Yujiro; Yoshii, Takahiko; Yoshii, Hidehiko; Satoh, Akinori; Asakuma, Junichi; Ito, Keiichi; Hayakawa, Masamichi; Asano, Tomohiko

    2010-03-01

    We evaluated the efficacy and outcome of one-stage oral mucosa graft urethroplasty, which is currently the procedure of choice for treating lengthy and complicated urethral strictures not amenable to excision and primary end-to-end anastomosis. Seven patients 33 to 74 years old (mean age = 53.7) underwent one-stage oral mucosa graft urethroplasty for a stricture in either the bulbar urethra (four patients), penile urethra (two patients), or pan-anterior urethra (one patient). Three of the strictures were due to trauma, one was due to inflammation, and one was due to a failed hypospadia repair. The other two were iatrogenic. All patients had previously undergone either internal urethrotomy or repeated urethral dilation. Three patients received a tube graft, three received a ventral onlay, and one received a dorsal onlay. A free graft of oral mucosa was harvested from the inside of each patient's left cheek, and if necessary to obtain a sufficient length, the harvest was extended to include mucosa from the lower lip and the right cheek. The graft lengths ranged from 2.5 to 12 cm (mean = 4.6 cm). A urethral catheter was left in place for 3 weeks postoperatively. While no severe complications at the donor site were observed during follow-up periods ranging from 3 to 55 months (mean = 14 months), two patients who had received a tube graft developed distal anastomotic ring strictures that were managed by internal urethrotomy. The other five required no postoperative urological procedure even though one who had received a ventral onlay developed a penoscrotal fistula. Oral mucosa is an ideal urethral graft, and oral mucosa graft urethroplasty is an effective procedure for repairing complicated urethral strictures involving long portions of the urethra.

  18. Modeling conduction in host-graft interactions between stem cell grafts and cardiomyocytes.

    Science.gov (United States)

    Chen, Michael Q; Yu, Jin; Whittington, R Hollis; Wu, Joseph C; Kovacs, Gregory T A; Giovangrandi, Laurent

    2009-01-01

    Cell therapy has recently made great strides towards aiding heart failure. However, while transplanted cells may electromechanically integrate into host tissue, there may not be a uniform propagation of a depolarization wave between the heterogeneous tissue boundaries. A model using microelectrode array technology that maps the electrical interactions between host and graft tissues in co-culture is presented and sheds light on the effects of having a mismatch of conduction properties at the boundary. Skeletal myoblasts co-cultured with cardiomyocytes demonstrated that conduction velocity significantly decreases at the boundary despite electromechanical coupling. In an attempt to improve the uniformity of conduction with host cells, differentiating human embryonic stem cells (hESC) were used in co-culture. Over the course of four to seven days, synchronous electrical activity was observed at the hESC boundary, implying differentiation and integration. Activity did not extend far past the boundary, and conduction velocity was significantly greater than that of the host tissue, implying the need for other external measures to properly match the conduction properties between host and graft tissue.

  19. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  20. MRI of normal anterior cruciate ligament (ACL) and reconstructed ACL: comparison of when the knee is extended with when the knee is flexed

    International Nuclear Information System (INIS)

    Nakanishi, K.; Horibe, S.; Shiozaki, Y.; Ishida, T.; Narumi, Y.; Ikezoe, J.; Nakamura, H.

    1997-01-01

    The purpose of this study was to evaluate, using MRI, the morphology of normal anterior cruciate ligament (ACL) and ACL grafts when the knee was extended compared with when the knee was flexed. Eighteen normal controls and 22 ACL graft patients were studied. Spin-echo (SE) T1-weighted images (TR 330 ms/TE 15 ms, NEX 1) were obtained with a slice thickness of 3 mm. Oblique sagittal images parallel to the ACL were obtained at various flexed angles of the knee joint. In 12 of the 18 normal controls the ACL appeared convex toward the posterior side when the knee was extended and gradually became straight when the knee was flexed. In 15 of the 22 ACL graft patients the grafts appeared straight when the knee was extended and became convex toward the anterior side when the knee was flexed. It is concluded that the morphological changes seen on MR images of ACL grafts from when the knee is extended to when the knee is flexed are different from those in the normal ACL. (orig.). With 7 figs., 1 tab

  1. Islet grafting and imaging in a bioengineered intramuscular space†

    Science.gov (United States)

    Witkowski, Piotr; Sondermeijer, Hugo; Hardy, Mark A.; Woodland, David C.; Lee, Keagan; Bhagat, Govind; Witkowski, Kajetan; See, Fiona; Rana, Abbas; Maffei, Antonella; Itescu, Silviu; Harris, Paul E.

    2011-01-01

    Background Since the hepatic portal system may not be the optimal site for islet transplantation, several extrahepatic sites have been studied. Here we examine an intramuscular transplantation site, bioengineered to better support islet neovascularization, engraftment, and survival, and demonstrate that at this novel site, grafted beta cell mass may be quantitated in a real time non-invasive manner by PET imaging. Methods Streptozotocin induced rats were pretreated intramuscularly with a biocompatible angiogenic scaffold received syngeneic islet transplants 2 weeks later. The recipients were monitored serially by blood glucose and glucose tolerance measurements and by PET imaging of the transplant site with [11C] dihydrotetrabenazine. Parallel histopathologic evaluation of the grafts was done using insulin staining and evaluation of microvasularity. Results Reversal of hyperglycemia by islet transplantation was most successful in recipients pretreated with bioscaffolds containing angiogenic factors as compared to those who received no bioscaffolds or bioscaffolds not treated with angiogenic factors. PET imaging with [11C] dihydrotetrabenazine, insulin staining and microvascular density patterns were consistent with islet survival, increased levels of angiogenesis, and with reversal of hyperglycemia. Conclusions Induction of increased neovascularization at an intramuscular site significantly improves islet transplant engraftment and survival compared to controls. The use of a non hepatic transplant site may avoid intrahepatic complications and permit the use of PET imaging to measure and follow transplanted beta-cell mass in real time. These findings have important implications for effective islet implantation outside of the liver, and offer promising possibilities for improving islet survival, monitoring, and even prevention of islet loss. PMID:19898201

  2. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  3. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  4. Injerto columelar extendido angulado. Método para prevenir la rotación cefálica y lateral de los injertos de cartílago en la punta nasal Angulated extended collumelar graft. A method to prevent the cephalic and lateral rotation of the cartilage graft in the nasal tip

    Directory of Open Access Journals (Sweden)

    Y. Castro Govea

    2011-06-01

    Full Text Available El paciente mestizo generalmente posee una nariz pequeña, de base ancha, con fosas nasales redondas y dorso convexo. Los cartílagos alares son débiles, delgados y cortos, proporcionando un soporte estructural deficiente y pobre definición de la punta nasal. Los injertos de cartílago de la punta nasal se usan frecuentemente para corregir esta condición; sin embargo un problema común es la rotación cefálica, caudal y lateral de estos cartílagos. Empleamos un injerto columelar extendido angulado (ICEA para proporcionar elongación y soporte columelar; la extensión angulada nos brinda a su vez un mejor control y predicción de la posición de los injertos de la punta nasal al prevenir su desplazamiento cefálico y lateral. El protocolo quirúrgico empleado incluyó historia clínica completa, desarrollo de un plan quirúrgico mediante análisis de la deformidad y fotografías pre y postoperatorias para el control de los pacientes a medio y largo plazo. Tratamos 95 pacientes usando este procedimiento; 75 con rinoplastia abierta y 20 con técnica cerrada. El rango del periodo de seguimiento fue de 6 meses a 4 años. Los resultados obtenidos fueron satisfactorios, mostrando mejor control y predicción de la forma de la punta nasal. En conclusión, creemos que el injerto columelar extendido angulado proporciona un mejor control de la proyección y angularidad de los injertos colocados en la punta nasal.The mestizo patient usually has a small nose, with wide base, round nostrils and convex dorsum. The alar cartilages are weak, thin and short, providing a deficient structural support and poor definition of the nasal tip. Cartilage graft in the nasal tip are very often used to correct this condition, but a commun problem of this procedure is the cephalic or lateral rotation of these grafts. We used an angulated extended collumalar graft to give collumelar support and elongation. The angulated extension of the graft provides a better control and

  5. Incremental Value of Increasing Number of Arterial Grafts: The Effect of Diabetes Mellitus.

    Science.gov (United States)

    Schwann, Thomas A; El Hage Sleiman, Abdul Karim M; Yammine, Maroun B; Tranbaugh, Robert F; Engoren, Milo; Bonnell, Mark R; Habib, Robert H

    2018-06-01

    Multiarterial coronary grafting with two arterial grafts leads to improved survival compared with conventional single artery based on left internal thoracic artery to left anterior descending artery and saphenous vein grafts. We investigated whether extending arterial grafting to three or more arterial grafts further improves survival, and whether such a benefit is modified by diabetes mellitus. We analyzed 15-year coronary artery bypass graft surgery mortality data in 11,931 patients (age 64.3 ± 10.5 years; 3,484 women [29.2%]; 4,377 [36.7%] with diabetes mellitus) derived from three US institutions (1994 to 2011). All underwent primary isolated left internal thoracic artery to left anterior descending artery grafting with at least two grafts: one artery (n = 6,782; 56.9%); two arteries (n = 3,678; 30.8%); or three or more arteries (n = 1,471; 12.3%). Long-term survival was estimated by Kaplan-Meier methods. Propensity score matching and comprehensive covariate adjustment (Cox regression) were used to derive long-term risk-adjusted hazard ratio (HR) with 95% confidence interval (CI) for increasing number of arterial grafts in the overall cohort and for diabetes and no-diabetes cohorts. Radial artery (94%) and right internal thoracic artery (6%) were used as additional arterial grafts. Multivariate analysis in all patients showed that diabetes was associated with decreased survival (HR 1.43, 95% CI: 1.34 to 53), whereas increasing number of arterial grafts was associated with decreased mortality (one artery HR 1.0 [reference]; two arteries HR 0.87, 95% CI: 0.80 to 0.95; and three arteries HR 0.83, 95% CI: 0.72 to 0.95). Pairwise comparisons also showed an incremental benefit of additional arterial grafts: two arteries versus one artery, HR 0.89 (95% CI: 0.80 to 0.98); and three arteries versus one artery, HR 0.80 (95% CI: 0.68 to 0.94). A three-artery versus two-artery survival advantage trend was also noted, but was not significant in either the overall study

  6. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  7. Development of a New Technique for Reconstruction of Hepatic Artery during Liver Transplantation in Sprague-Dawley Rat.

    Directory of Open Access Journals (Sweden)

    Xingmu Liu

    Full Text Available Sleeve anastomosis is the most common technique used to rearterialize orthotopic liver transplants (OLT. However, this technique has a number of disadvantages, including difficulty of performance of the technique visually unaided. We herein describe a novel rearterialized OLT model in the rat.Forty-six male Sprague Dawley rats (300-400 g were used as donors and recipients. Based on Kamada's cuff technique, the new model involved performing a modified "sleeve" anastomosis between the celiac trunk of the donor and common hepatic artery of the recipient to reconstruct blood flow to the hepatic artery. An additional ten male Sprague Dawley rats underwent liver transplantation without artery reconstruction. Liver grafts were retrieved from the two groups and histological examination was performed following surgery.Total mean operating times were ~42 minutes for the donor liver extraction and 57 minutes for the recipient transplantation. Graft preparation took an additional 15 minutes and the time to fix the arterial bracket was ~3 minutes. During transplantation, the anhepatic phase lasted 18 ± 2.5 min and the artery reconstruction only required ~3 minutes. The patency rate was 94.44% and the 4-week survival rate was 90%. Histology indicated obvious fibrosis in the liver grafts without artery reconstruction, while normal histology was observed in the arterialized graft.This new method allows for the surgical procedure to be performed visually unaided with good survival and patency rates and represents an alternative model investigating OLT in rats.

  8. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy; Nevens, Frederik; Verslype, Chris; Wilmer, Alexander

    2004-01-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  9. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    Energy Technology Data Exchange (ETDEWEB)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy [University Hospitals Gasthuisberg, Department of Radiology, Leuven (Belgium); Nevens, Frederik; Verslype, Chris [University Hospitals Gasthuisberg, Department of Hepatology, Leuven (Belgium); Wilmer, Alexander [University Hospitals Gasthuisberg, Department of Medical Intensive Care Unit, Leuven (Belgium)

    2004-10-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  10. Grafting the alar rim: application as anatomical graft.

    Science.gov (United States)

    Gruber, Ronald P; Fox, Paige; Peled, Anne; Belek, Kyle A

    2014-12-01

    Alar rim contour and alar rim grafts have become essential components of rhinoplasty. Ideally, grafts of the nose should be anatomical in shape. So doing might make grafts of the alar rim more robust. The authors considered doing that by applying the graft as a continuous extension of the lateral crus. Twelve patients (two men and 10 women) constituted the study group (seven primary and five secondary cases). Of those, there were five concave rims, two concave rims with rim retraction, two boxy tips, and three cephalically oriented lateral crura. Surgical technique included the following: (1) an open approach was used; (2) a marginal incision that ignored the caudal margin of the lateral crus (the incision went straight posteriorly to a point 5 to 6 mm from the rim margin) was used; (3) a triangular graft was made to cover the exposed vestibular skin; (4) it was secured end to end to the caudal border of the lateral crus; and (5) the poster end was allowed to sit in a small subcutaneous pocket. Follow-up was 11 to 19 months. All 12 patients exhibited good rims as judged by a blinded panel. Rim retraction was not fully corrected in one patient, but no further treatment was required. One patient did require a secondary small rim graft for residual rim concavity. The concept of grafting the alar rim is strongly supported by the authors' results. The modifications the authors applied by designing the graft to be anatomical in shape has been a technical help.

  11. Reconstruction of mandibular defects using nonvascularized autogenous bone graft in Nigerians

    Directory of Open Access Journals (Sweden)

    Kizito Chioma Ndukwe

    2014-01-01

    Full Text Available Objectives: The aim of this study is to evaluate the success rate and complications of mandibular reconstruction with nonvascularized bone graft in Ile-Ife, Nigeria. Patients and Methods: A total of 25 patients who underwent reconstruction of mandibular discontinuity defects between January 2003 and February 2012, at the Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife constituted the study sample. Relevant information was retrieved from the patients′ records. This information include patients′ demographics (age and sex as well as the type of mandibular defect, cause of the defect, type of mandibular resection done, source of the bone graft used, and the method of graft immobilization. Morbidity associated with the graft procedures were assessed by retrieving information on graft failures, length of hospital stay following surgery, rehabilitation device used and associated graft donor and recipient site complications. Result: There were 12 males and 13 females with a male:female ratio was 1:1.1. The age of the patients ranged from 13 to 73 years with a mean age for males 32.7 ± standard deviation (SD 12.9 and for females 35.0 ± SD 17.1. Jaw defect was caused by resection for tumours and other jaw pathologies in 92% of cases. Complete symphyseal involvement defect was the most common defect recorded 11 (44%. Reconstruction with nonvascularized rib graft accounted for 68% of cases while iliac crest graft was used in 32% of the patients. Successful take of the grafts was recorded in 22 patients while three cases failed. Wound dehiscence (two patients and postoperative wound infection (eight patients were the most common complications recorded. Conclusion: The use of nonvascularized graft is still relevant in the reconstruction of large mandibular defects caused by surgical ablation of benign conditions in Nigerians. Precise surgical planning and execution, extended antibiotic therapy, and meticulous postoperative care

  12. Cryo-chemical decellularization of the whole liver for mesenchymal stem cells-based functional hepatic tissue engineering.

    Science.gov (United States)

    Jiang, Wei-Cheng; Cheng, Yu-Hao; Yen, Meng-Hua; Chang, Yin; Yang, Vincent W; Lee, Oscar K

    2014-04-01

    Liver transplantation is the ultimate treatment for severe hepatic failure to date. However, the limited supply of donor organs has severely hampered this treatment. So far, great potentials of using mesenchymal stem cells (MSCs) to replenish the hepatic cell population have been shown; nevertheless, there still is a lack of an optimal three-dimensional scaffold for generation of well-transplantable hepatic tissues. In this study, we utilized a cryo-chemical decellularization method which combines physical and chemical approach to generate acellular liver scaffolds (ALS) from the whole liver. The produced ALS provides a biomimetic three-dimensional environment to support hepatic differentiation of MSCs, evidenced by expression of hepatic-associated genes and marker protein, glycogen storage, albumin secretion, and urea production. It is also found that hepatic differentiation of MSCs within the ALS is much more efficient than two-dimensional culture in vitro. Importantly, the hepatic-like tissues (HLT) generated by repopulating ALS with MSCs are able to act as functional grafts and rescue lethal hepatic failure after transplantation in vivo. In summary, the cryo-chemical method used in this study is suitable for decellularization of liver and create acellular scaffolds that can support hepatic differentiation of MSCs and be used to fabricate functional tissue-engineered liver constructs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  14. Outcomes of Renal Allograft Recipients With Hepatitis C.

    Science.gov (United States)

    Carpio, R; Pamugas, G E; Danguilan, R; Que, E

    2016-04-01

    Studies on the effect of hepatitis C virus (HCV) infection showed decreased graft survival compared to HCV-negative matched patients. It was also identified as an independent risk factor for graft loss and mortality in kidney transplantation patients. This study was designed to evaluate the 10-year graft and patient outcomes of renal allograft recipients with HCV infection at the National Kidney and Transplant Institute. This is a retrospective study of patients who underwent renal transplantation with HCV infection and a group who were HCV-negative in the same post-transplantation period. Data were gathered from the in-patient and out-patient clinic records. Patient survival was significantly lower in the HCV-positive than in the HCV-negative group. The mean duration of patient survival was 154.95 (+4.95) months (12 years and 10 months) in HCV-negative patients compared to 141 (+6.52) months (11 years and 9 months) in the HCV-positive group (P = .05). Graft survival did not differ significantly between HCV-positive and HCV-negative recipients (P = .734). The mean duration of graft survival was 137 (+7.68) months (11 years and 5 months) in HCV-negative patients compared to 130 (+6.84) months (10 years and 10 months) in HCV-positive patients. Short- and long-term outcomes including biopsy-proven acute rejection, transplant glomerulopathy, chronic allograft nephropathy, renal function, and proteinuria were similar in both groups. Rejection, glomerulopathy, and renal function were similar in both groups. HCV progression was also observed in patients with detectable HCV-RNA 6 months before transplantation. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  16. Effect of bidispersity in grafted chain length on grafted chain conformations and potential of mean force between polymer grafted nanoparticles in a homopolymer matrix.

    Science.gov (United States)

    Nair, Nitish; Wentzel, Nathaniel; Jayaraman, Arthi

    2011-05-21

    In efforts to produce polymeric materials with tailored physical properties, significant interest has grown around the ability to control the spatial organization of nanoparticles in polymer nanocomposites. One way to achieve controlled particle arrangement is by grafting the nanoparticle surface with polymers that are compatible with the matrix, thus manipulating the interfacial interactions between the nanoparticles and the polymer matrix. Previous work has shown that the molecular weight of the grafted polymer, both at high grafting density and low grafting density, plays a key role in dictating the effective inter-particle interactions in a polymer matrix. At high grafting density nanoparticles disperse (aggregate) if the graft molecular weight is higher (lower) than the matrix molecular weight. At low grafting density the longer grafts can better shield the nanoparticle surface from direct particle-particle contacts than the shorter grafts and lead to the dispersion of the grafted particles in the matrix. Despite the importance of graft molecular weight, and evidence of non-trivial effects of polydispersity of chains grafted on flat surfaces, most theoretical work on polymer grafted nanoparticles has only focused on monodisperse grafted chains. In this paper, we focus on how bidispersity in grafted chain lengths affects the grafted chain conformations and inter-particle interactions in an implicit solvent and in a dense homopolymer polymer matrix. We first present the effects of bidispersity on grafted chain conformations in a single polymer grafted particle using purely Monte Carlo (MC) simulations. This is followed by calculations of the potential of mean force (PMF) between two grafted particles in a polymer matrix using a self-consistent Polymer Reference Interaction Site Model theory-Monte Carlo simulation approach. Monte Carlo simulations of a single polymer grafted particle in an implicit solvent show that in the bidisperse polymer grafted particles

  17. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  18. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  19. Hepatitis C and liver transplantation.

    Science.gov (United States)

    Martini, Silvia

    2018-06-01

    Hepatitis C virus (HCV)-related liver disease represents the leading indication for liver transplantation (LT) in the USA and Europe and HCV recurrence is universal in recipients who are viremic at LT. Until a few years ago, pegylated-interferon in association with ribavirin was the only therapeutic strategy, usable only in compensated cirrhotic patients, in order to prevent post-LT viral recurrence. The recent advent of direct-acting antiviral agents (DAAs) has dramatically increased the chances of curative treatment for the transplant population and the debate about which should be the best time for treating the infection is still open: whether to pursue HCV eradication 1) before LT, in order to improve liver function, delist some patients and prevent graft infection; or 2) as early as possible after LT, rather than 3) waiting for hepatitis C recurrence before starting treatment. In addition, in the DAA era, the use of HCV-positive donors may represent a potential approach to safely expanding the donor pool. As more HCV patients achieve cure with DAA regimens, the LT trend for HCV in the future would be expected to mimic the trend observed for hepatitis B virus in the past decade and in the United States, during the DAA-period 2014-2015, the rate of LT wait-listing for HCV complicated by decompensated cirrhosis has already decreased by 32%. This review summarizes the published data and emphasizes DAA treatment applicability to patients with decompensated cirrhosis and to liver transplant recipients.

  20. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  1. Trimetazidine: IS it a promising drug for use in steatotic grafts?

    Institute of Scientific and Technical Information of China (English)

    Ismail Ben Mosbah; Araní Casillas-Ramírez; Carme Xaus; Anna Serafín; Joan Roselló-Catafau; Carmen Peralta

    2006-01-01

    AIM: Chronic organ-donor shortage has led to the acceptance of steatotic livers for transplantation, despite the higher risk of graft dysfunction or nonfunction associated with the ischemic preservation period of these organs. The present study evaluates the effects of trimetazidine (TMZ) on an isolated perfused liver model.METHODS: Steatotic and non-steatotic livers were preserved for 24 h in the University of Wisconsin (UW)solution with or without TMZ. Hepatic injury and function (transaminases, bile production and sulfobromophthalein (BSP) clearance) and factors potentially involved in the susceptibility of steatotic livers to ischemia-reperfusion (I/R) injury, including oxidative stress, mitochondrial damage, microcirculatory diseases, and ATP depletion were evaluated.RESULTS: Steatotic livers preserved in UW solution showed higher transaminase levels, lower bile production and BSP clearance compared with non-steatotic livers.Alterations in perfusion flow rate and vascular resistance,mitochondrial damage, and reduced ATP content were more evident in steatotic livers. TMZ addition to UW solution reduced hepatic injury and ameliorated hepatic functionality in both types of the liver and protected against the mechanisms potentially responsible for the poor tolerance of steatotic livers to I/R.CONCLUSION: TMZ may constitute a useful approach in fatty liver surgery, limiting the inherent risk of steatotic liver failure following transplantation.

  2. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  3. [Comparative analysis of one- and two-stage augmentation urethroplasty with dorsal INLAY buccal graft for extended stricturesof spongious urethra].

    Science.gov (United States)

    Kogan, M I; Glukhov, V P; Mitusov, V V; Krasulin, V V; Ilyash, A V

    2018-03-01

    Urethral reconstructive surgery is in constant development. At present, reconstructive urethroplasty with buccal mucosa is increasingly being used. The study aimed to compare the results of a one- and two-stage augmentation urethroplasty with dorsal inlay buccal graft for strictures of the spongious urethra. The study comprised 72 patients aged 19-64 with urethral strictures 3-18 cm long. In 34 (47.2%) patients, the stricture was localized in the penile urethra, in 30 patients (41.6%) in the penile-bulbous urethra and in 8 patients (11%) in the bulbous urethra. All patients underwent augmentation urethroplasty with dorsal inlay buccal graft. The results were evaluated separately in 55 (76.4%, group 1) and 17 (23.6%, group 2) patients who underwent one-stage and two-stage surgery, respectively. The incidence rate of early postoperative complications was higher after one-stage (23.6%) compared two-stage surgery (11.8%) (purethroplasty with dorsal inlay buccal graft was achieved in 88.9% of patients; treatment effectiveness in the group 1 was 89.1%, in the group 2 - 88.2% (p>0.05). The final effectiveness of the operation, achieved with the use of additional surgical interventions, is estimated at 98.6%. The results of augmentation urethroplasty with dorsal inlay buccal graft do not depend on the number of stages, but fewer complications accompany two-stage surgery.

  4. Construction of a humanized antibody to hepatitis B surface antigen by specificity-determining residues (SDR)-grafting and de-immunization.

    Science.gov (United States)

    Kim, Keun-Soo; Kim, Hyun-Jung; Han, Byung Woo; Myung, Pyung-Keun; Hong, Hyo Jeong

    2010-05-28

    We previously constructed a humanized antibody, HuS10, by grafting the complementarity-determining regions (CDRs) of a parental murine monoclonal antibody into the homologous human antibody sequences. This process is termed CDR grafting. Some residues that were thought to affect the CDR loops and stabilize the structure of the variable regions were retained in the framework region. HuS10 exhibited in vivo virus-neutralizing activity, but its murine content had the potential to elicit immune responses in patients. In this study, to minimize the immunogenic potential of HuS10, we replaced 17 mouse residues in HuS10 with the comparable human residues using specificity-determining residue (SDR)-grafting and de-immunization methods. The resultant humanized antibody, HzS-III, had the same affinity and epitope specificity as HuS10 and had reduced immunogenic potential, as assessed by T-cell epitope analysis. Thus, SDR grafting in combination with de-immunization may be a useful strategy for minimizing the immunogenicity of humanized antibodies. In addition, HzS-III may be a good candidate for immunoprophylaxis of HBV infection. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  5. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  6. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  7. Graft irradiation abrogates graft-versus-host disease in combined pancreas-spleen transplantation

    International Nuclear Information System (INIS)

    Schulak, J.A.; Sharp, W.J.

    1986-01-01

    A model of combined pancreas-spleen transplantation (PST) was studied in LBN F1 recipients of Lewis grafts in order to evaluate the efficacy of pretransplant graft irradiation in preventing lethal graft-versus-host disease (GVHD). Recipients of unmodified PST uniformly developed severe GVHD and died (MST = 16.7 +/- 3.8 days). Whole body donor irradiation with either 500 or 250 rad prevented lethal GVHD. Similarly, ex vivo graft irradiation with either 1000 or 500 rad also resulted in normal weight gain, graft function, and host survival for the 6-week study period. Conversely, delay of graft irradiation until 3 days after transplantation failed to prevent this complication (MST = 15.8 +/- 3.7 days). Recipients of irradiated grafts displayed glucose tolerance tests that were identical to those in the control group indicating that the doses of radiation employed in these experiments were not deleterious to islet function. Irradiated spleen grafts appeared histologically normal at 6 weeks after transplantation. Cells derived from these grafts failed to stimulate lymph node enlargement in a popliteal lymph node assay for GVHD, suggesting that these spleens may have become repopulated with host cells. These experiments confirm that PST has the potential to cause lethal GVHD and suggest that pretransplant graft irradiation may be used to prevent its occurrence

  8. Effect of Grafting Method, Graft Cover and Foliar Spray of some Mineral Elements on Persian Walnut Graft-take and Winter Survival Rate

    Directory of Open Access Journals (Sweden)

    Reza Rezaee

    2017-09-01

    Full Text Available Introduction: Persian walnut (Juglans regia L. is an important nut crop in Iran and many parts of the world. One of the major challenges of growing walnut is planting of non-grafted walnut trees in orchards, which leads to the reduction of yield, quality and productivity of walnut orchards. Compared to the other fruit trees, walnut grafting is difficult and even newly grafted walnut seedlings are vulnerable to fall or winter frost chilling, so that most of the seedlings are lost after subjecting to the cold winter. There are a few studies reporting successful grafting in outdoor conditions, however, final grafting take after winter has been usually ignored. Hence, increased walnut grafting success and improved tree growth after grafting through foliar nutrient application may lead to increased tolerance of chilling. Therefore, main goals of this research were to investigate the effect of some graft covers and role of foliar spray of calcium, boron and zinc on the reduction of frost damage in newly grafted seedlings under outdoor conditions. Materials and methods: This research was conducted at agricultural research station, Khoy city, west Azerbaijan province, during 2012-2014. In the first experiment, three methods of grafting including cleft, bark and V-shaped, and two kinds of graft covers including moist sawdust and superabsorbent plus cotton wool were investigated in terms of grafting success and quality of seedlings. In the second experiment, effect of the three above-mentioned grafting methods and two levels of foliar spray including sequential spray of Ca (4 ppm, B and Zn (2% (3 times during growth season and control (no spray were studied in terms of frost damage. The experiments conducted in factorial based on randomized complete block design with 10 trees in each plot. Data were collected 45 days after grafting take, final grafting take after one winter, subsequent scion growth length and diameter and concentration of Ca, B and Zn in

  9. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  10. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Science.gov (United States)

    Chan, Alex H P; Tan, Richard P; Michael, Praveesuda L; Lee, Bob S L; Vanags, Laura Z; Ng, Martin K C; Bursill, Christina A; Wise, Steven G

    2017-01-01

    Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL) we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM) analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP). This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days). We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  11. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Directory of Open Access Journals (Sweden)

    Alex H P Chan

    Full Text Available Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP. This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days. We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  12. Delayed grafting for banked skin graft in lymph node flap transfer.

    Science.gov (United States)

    Ciudad, Pedro; Date, Shivprasad; Orfaniotis, Georgios; Dower, Rory; Nicoli, Fabio; Maruccia, Michele; Lin, Shu-Ping; Chuang, Chu-Yi; Chuang, Tsan-Yu; Wang, Gou-Jen; Chen, Hung-Chi

    2017-02-01

    Over the last decade, lymph node flap (LNF) transfer has turned out to be an effective method in the management of lymphoedema of extremities. Most of the time, the pockets created for LNF cannot be closed primarily and need to be resurfaced with split thickness skin grafts. Partial graft loss was frequently noted in these cases. The need to prevent graft loss on these iatrogenic wounds made us explore the possibility of attempting delayed skin grafting. We have herein reported our experience with delayed grafting with autologous banked split skin grafts in cases of LNF transfer for lymphoedema of the extremities. Ten patients with International Society of Lymphology stage II-III lymphoedema of upper or lower extremity were included in this study over an 8-month period. All patients were thoroughly evaluated and subjected to lymph node flap transfer. The split skin graft was harvested and banked at the donor site, avoiding immediate resurfacing over the flap. The same was carried out in an aseptic manner as a bedside procedure after confirming flap viability and allowing flap swelling to subside. Patients were followed up to evaluate long-term outcomes. Flap survival was 100%. Successful delayed skin grafting was done between the 4th and 6th post-operative day as a bedside procedure under local anaesthesia. The split thickness skin grafts (STSG) takes more than 97%. One patient needed additional medications during the bedside procedure. All patients had minimal post-operative pain and skin graft requirement. The patients were also reported to be satisfied with the final aesthetic results. There were no complications related to either the skin grafts or donor sites during the entire period of follow-up. Delayed split skin grafting is a reliable method of resurfacing lymph node flaps and has been shown to reduce the possibility of flap complications as well as the operative time and costs. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  13. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  14. Baseline MELD score predicts hepatic decompensation during antiviral therapy in patients with chronic hepatitis C and advanced cirrhosis.

    Directory of Open Access Journals (Sweden)

    Georg Dultz

    Full Text Available In patients with advanced liver cirrhosis due to chronic hepatitis C virus (HCV infection antiviral therapy with peginterferon and ribavirin is feasible in selected cases only due to potentially life-threatening side effects. However, predictive factors associated with hepatic decompensation during antiviral therapy are poorly defined.In a retrospective cohort study, 68 patients with HCV-associated liver cirrhosis (mean MELD score 9.18 ± 2.72 were treated with peginterferon and ribavirin. Clinical events indicating hepatic decompensation (onset of ascites, hepatic encephalopathy, upper gastrointestinal bleeding, hospitalization as well as laboratory data were recorded at baseline and during a follow up period of 72 weeks after initiation of antiviral therapy. To monitor long term sequelae of end stage liver disease an extended follow up for HCC development, transplantation and death was applied (240 weeks, ± SD 136 weeks.Eighteen patients (26.5% achieved a sustained virologic response. During the observational period a hepatic decompensation was observed in 36.8%. Patients with hepatic decompensation had higher MELD scores (10.84 vs. 8.23, p14, respectively. Baseline MELD score was significantly associated with the risk for transplantation/death (p<0.001.Our data suggest that the baseline MELD score predicts the risk of hepatic decompensation during antiviral therapy and thus contributes to decision making when antiviral therapy is discussed in HCV patients with advanced liver cirrhosis.

  15. Evaluation of Replacement Grafts and Punch Grafts in the Treatment of Vitiligo

    Directory of Open Access Journals (Sweden)

    Singh Ajit Kumar

    1980-01-01

    Full Text Available Thirtycasesof vitiligo eachwithminimum of two lesions undent replacement graft and multiple punch grafts in one lesion each. Complications observed at the recipient site like infection and raised nigosed surface were significantly more in replacement grafts. Hypopigmentation of the graft was significantly more when the disease was progressive.

  16. [Long term effect of hepatitis B and C virus infection on the survival of kidney transplant patients].

    Science.gov (United States)

    Corrêa, José Roberto Missel; Rocha, Fabrício Domingos; Peres, Alessandro Afonso; Gonçalves, Luiz Felipe; Manfro, Roberto Ceratti

    2003-01-01

    To evaluate the impact of HCV (hepatitis C virus) and HBV (hepatitis B virus) infection on long-term graft and patient survival in renal transplantation. One hundred and nine kidney allograft recipients were evaluated regarding the presence of antibodies against HCV and hepatitis B surface antigen. Patients were divided into four groups according to their serologic status and followed for ten years for survival analysis. Age, gender, renal failure etiology, length of previous dialysis and post transplantation periods were evaluated. Length on dialysis time was significantly longer in the anti-HCV positive group. There was also a higher number of patients with re-transplants in the HBV and HCV groups. There were no significant differences in 10-year patient survival in the anti-HCV positive group (71.0%; relative risk: 1.13; CI: 0.86-1.47) and in the HBV infected group (77.8%; relative risk: 1.03; CI: 0.7-1.5) compared to the not infected group (80%). However, the group of patients infected with both viruses presented a significantly lower 10-year patient survival (37.5%; relative risk: 2.13; CI: 0.86-5.28) compared to the index group. There were no significant differences on graft survival among the groups. In the present study renal transplant patients infected concomitantly with HBV and HCV present a significantly lower long-term patient survival.

  17. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  18. Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

    Directory of Open Access Journals (Sweden)

    Jung Dug Yang

    2016-09-01

    Full Text Available BackgroundSkin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute.MethodsThis prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A, and RapiGraft and split-thickness skin grafting were used on the other side (group B. All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS, a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months.ResultsThe skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082. Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all. However, the groups did not differ significantly in pliability (P=0.155.ConclusionsThe present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

  19. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  20. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  1. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  2. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  3. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  4. Graft union formation in artichoke grafting onto wild and cultivated cardoon: an anatomical study.

    Science.gov (United States)

    Trinchera, Alessandra; Pandozy, Gianmarco; Rinaldi, Simona; Crinò, Paola; Temperini, Olindo; Rea, Elvira

    2013-12-15

    In order to develop a non-chemical method such as grafting effective against well-known artichoke soil borne diseases, an anatomical study of union formation in artichoke grafted onto selected wild and cultivated cardoon rootstocks, both resistant to Verticillium wilt, was performed. The cardoon accessions Belgio (cultivated cardoon) and Sardo (wild cardoon) were selected as rootstocks for grafting combinations with the artichoke cv. Romolo. Grafting experiments were carried out in the autumn and spring. The anatomical investigation of grafting union formation was conducted by scanning electron microscopy (SEM) on the grafting portions at the 3rd, 6th, 10th, 12th day after grafting. For the autumn experiment only, SEM analysis was also performed at 30 d after grafting. A high affinity between artichoke scion and cardoon rootstocks was observed, with some genotype differences in healing time between the two bionts. SEM images of scion/rootstock longitudinal sections revealed the appearance of many interconnecting structures between the two grafting components just 3d after grafting, followed by a vascular rearrangement and a callus development during graft union formation. De novo formation of many plasmodesmata between scion and rootstock confirmed their high compatibility, particularly in the globe artichoke/wild cardoon combination. Moreover, the duration of the early-stage grafting process could be influenced not only by the scion/rootstock compatibility, but also by the seasonal conditions, being favored by lower temperatures and a reduced light/dark photoperiod. Copyright © 2013 Elsevier GmbH. All rights reserved.

  5. The use of short spreader grafts in rhinoplasty for patients with thick nasal skin.

    Science.gov (United States)

    Grigoryants, Vladimir; Baroni, Arpa

    2013-06-01

    Thick nasal skin presents a challenge in rhinoplasty. Conventional spreader grafts in patients with thick nasal skin may result in an undesirable widening of the lower half of the nose where the nasal skin is thick. The use of short spreader grafts was evaluated in patients with thick nasal skin. For this study, 32 patients underwent closed rhinoplasty in which short spreader grafts were used. The spreader graft was 1 to 2 cm long and extended only to the transition of thin and thick nasal skin. The patients were followed for more than 1 year postoperatively. Aesthetic improvement was observed in all the patients. Nasal airway patency was improved or maintained in 94 % of the patients. Short spreader grafts effectively restore or maintain the internal nasal valve area after dorsal hump reduction while allowing for more aggressive narrowing of the lower part of the nose where nasal skin is thick. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  6. Antibiotic prophylaxis and risk of Clostridium difficile infection after coronary artery bypass graft surgery.

    Science.gov (United States)

    Poeran, Jashvant; Mazumdar, Madhu; Rasul, Rehana; Meyer, Joanne; Sacks, Henry S; Koll, Brian S; Wallach, Frances R; Moskowitz, Alan; Gelijns, Annetine C

    2016-02-01

    Antibiotic use, particularly type and duration, is a crucial modifiable risk factor for Clostridium difficile. Cardiac surgery is of particular interest because prophylactic antibiotics are recommended for 48 hours or less (vs ≤24 hours for noncardiac surgery), with increasing vancomycin use. We aimed to study associations between antibiotic prophylaxis (duration/vancomycin use) and C difficile among patients undergoing coronary artery bypass grafting. We extracted data on coronary artery bypass grafting procedures from the national Premier Perspective claims database (2006-2013, n = 154,200, 233 hospitals). Multilevel multivariable logistic regressions measured associations between (1) duration (difficile as outcome. Overall C difficile prevalence was 0.21% (n = 329). Most patients (59.7%) received a cephalosporin only; in 33.1% vancomycin was added, whereas 7.2% received vancomycin only. Extended prophylaxis was used in 20.9%. In adjusted analyses, extended prophylaxis (vs standard) was associated with significantly increased C difficile risk (odds ratio, 1.43; confidence interval, 1.07-1.92), whereas no significant associations existed for vancomycin use as adjuvant or primary prophylactic compared with the use of cephalosporins (odds ratio, 1.21; confidence interval, 0.92-1.60, and odds ratio, 1.39; confidence interval, 0.94-2.05, respectively). Substantial inter-hospital variation exists in the percentage of extended antibiotic prophylaxis (interquartile range, 2.5-35.7), use of adjuvant vancomycin (interquartile range, 4.2-61.1), and vancomycin alone (interquartile range, 2.3-10.4). Although extended use of antibiotic prophylaxis was associated with increased C difficile risk after coronary artery bypass grafting, vancomycin use was not. The observed hospital variation in antibiotic prophylaxis practices suggests great potential for efforts aimed at standardizing practices that subsequently could reduce C difficile risk. Copyright © 2016 The

  7. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  8. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  9. Counter-attack on viral hepatitis. [Hepatitis A; Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Prozesky, O W [Pretoria Univ. (South Africa). Dept. of Medical Virology; Jupp, P G; Joubert, J J; Taylor, M B; Grabow, W O.K.

    1985-07-01

    The most highly developed radioimmunoassay test system in medical virology is proving of exceptional value in research aimed at controlling and eventually eradicating the scourge of human hepatitis. The use of radioimmunoassay in detecting hepatitis A (HAV) and hepatitis B (HBV) viruses is discussed. The hepatitis A virus is an enterovirus which infects the gastrointestinal tract and is usually transmitted by contaminated food, milk or water. Hepatitis B spreads mainly by the parenteral rate. Bedbugs and ticks are considered as possible transmitters of HBV. Another important contribution of radioimmunoassay is the ability to monitor the immune response of persons at risk who are vaccinated against hepatitis B.

  10. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  11. The use of sofosbuvir for the treatment of recurrent hepatitis C after liver transplantation

    Directory of Open Access Journals (Sweden)

    M. Sh. Khubutiya

    2017-01-01

    Full Text Available The article presents the experience of direct-acting antiviral (DAA drug treatment for hepatitis C in the patients after liver transplantation. The end-stage liver disease caused by hepatitis C is the main indication for orthotopic liver transplantation (OLT. In 2013, the first agent in the class of antiviral drugs directly acting on hepatitis C virus (HCV was introduced into clinical practice. That was sofosbuvir, a HCV polymerase inhibitor, that could be used without interferon alfa.Materials and methods. The study enrolled 33 liver transplant recipients with recurrent hepatitis C. Thirty-five courses of antiviral therapy (AT were conducted with sofosbuvir being one of AT components.Results. By the time of analysis, 21 patients had completed the antiviral therapy. All the patients showed an initial response to the antiviral therapy, HCV aviremia was achieved. In 3 patients, with the evaluable sustained virologic response (SVR, a renewed HCV replication was observed in the first weeks after the AT completion.Conclusion. The new direct-acting antiviral drugs offer an effective antiviral therapy to all liver graft recipients with recurrent HCV.

  12. Study on grafting of monomer onto natural rubber latex by radiation technique

    International Nuclear Information System (INIS)

    Nguyen Tan Man; Le Hai; Tran Thi Tam; Le Huu Tu, Pham Thi Sam; Dao Minh Phuong; Ha Thuc Huy

    2004-01-01

    Radiation vulcanization of natural rubber latex has been extensively developed through programmers assisted by the IAEA and UNDP under RCA in Asia and Pacific Region. R-D has been done in most of the Member States with technical assistance from Japan's Takasaki Radiation Chemistry Establishment. Radiation vulcanized natural rubber latex (RVNRL) has many advantages over the conventional sulfur vulcanized latex, such as absence of nitrosamine and low cytotoxicity. Radiation crosslinking is a room temperature process, itself an important cost advantage, it is easily controlled and desired extend of crosslinking is easily achieved by controlling the dose (irradiation time). Disadvantages of RVNRL to be improved are poor physical properties of film such as low tensile strength and tear strength. The research groups of Japan, Thailand and Indonesia concentrated on the improvement of physical properties of RVNRL using radiation grafted PMMA as additive [2]. F. Sundardi and W. Sofiarti have reported that tensile strength and hardness increased by radiation grafting of styrene onto NR [5]. Ono et al have reported the grafting of MMA onto NR by gamma irradiation at a dose of 5 kGy for producing thermoplastic elastomers [4]. The objective of this project is to report the results of studies of radiation graft-copolymerization of methyl methacrylate (MMA) or styrene (St) onto natural rubber latex in order to improve their physico-mechanical properties and evaluation of grafted material using Small-Angle Neutron Scattering through FNCA Project. The grafting degree of MMA and St onto NR increased with the increase of irradiation dose and monomer concentration. The alteration of grafted products structure was determined by IR method. Tensile strength, Shore A hardness, 100% modulus of grafted products increased with the increase of monomer concentration and irradiation dose while elongation at break decreased. The grafted products were characterized by Transmission Electron

  13. Concurrent Hepatic Artery and Portal Vein Thrombosis after Orthotopic Liver Transplantation with Preserved Allografts

    Directory of Open Access Journals (Sweden)

    Arshad Khan

    2014-01-01

    Full Text Available In contrast to early HAT, late HAT has an insidious clinical presentation. Nevertheless, biliary and vascular reconstructions in this late setting are unlikely to improve outcome. Patent portal flow makes an important contribution to the viability of liver in case of late HAT while the allograft reconstitutes intrahepatic arterial flow through neovascularization. Concurrent HAT with PVT without immediate graft necrosis is extremely rare, and allograft and patient survival are seemingly impossible without retransplantation. In fact, hepatopetal arterial and portal venous neovascularization are known albeit obscure phenomena that can preserve posttransplant hepatic function under the extenuating circumstances of complete interruption of blood flow to the graft. We describe two such cases that developed combined HAT and PVT more than six months after OLT with perfect preservation of graft function. The survival of allografts in our cases was due to extensive hepatopetal arterial and portal venous collateralization. Simultaneous HAT and PVT after OLT are rare events and almost uniformly fatal, if they occur early. Due to paucity of such cases, however, underlying mechanisms and etiology remain elusive, and despite radiological diagnosis of these complications, there is no way to predict these events in the wake of stable graft function.

  14. Modification of polyetherurethane for biomedical application by radiation-induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1985-01-01

    Radiation grafting of monomers onto suitable trunk polymers is a useful tool for tailoring new polymers for special purposes. This technique has been used in the past for the development of biocompatible materials, e.g., by grafting hydrogels onto mechanically stable polymers. In this first part of our work, the radiation grafting of hydrophilic or reactive monomers onto a polyetherurethane film using the pre-swelling technique is described. Following this technique the trunk polymer was swollen in the monomer before irradiation. As monomers 2-hydroxyethyl methacrylate (HEMA), 2,3-epoxypropyl methacrylate (GMA), 2,3-dihydroxypropyl methacrylate (GOMA), and acrylamide (AAm) were used. The kinetics of the grafting reactions were examined, and the distribution of the graft component inside the trunk polymer was investigated by means of infrared (IR) spectroscopy. Surface-grafted as well as bulk- and surface-grafted products could be obtained. The mechanical behavior of the grafted films--especially in the water-swollen state--was examined and compared with that of the pure trunk polymer. In nearly all cases it was found that the tensile strength sigma B and the elongation at break epsilon R decreases as the grafting yield increases. Modification of GMA- and AAm-grafted films via chemical reactions was performed to create new functional groups of biomedical interest. In this manner a diol structure, a carboxylic acid structure, and a sulfonic acid group could be introduced in the grafted polymer. The water uptake of such modified films is increased markedly when compared with that of the unmodified samples

  15. A Comparative Outcome Study of Hamstring Versus Tibialis Anterior and Synthetic Grafts for Deltoid to Triceps Transfers.

    Science.gov (United States)

    Dunn, Jennifer A; Mohammed, Khalid D; Beadel, Gordon P; Rothwell, Alastair G; Simcock, Jeremy W

    2017-10-01

    To assess elbow extension strength and complications after deltoid-triceps transfers using hamstring tendon graft compared with tibialis anterior and synthetic tendon grafts. A retrospective review of deltoid-triceps transfers in patients with tetraplegia performed between 1983 and 2014. Seventy-five people (136 arms) had surgery performed, with the majority undergoing simultaneous bilateral surgery (n = 61; 81%). Tibialis anterior tendon grafts were used in 68 arms, synthetic grafts in 23 arms, and hamstring tendon grafts in 45 arms. The average age at surgery was 31 years. Sixty-three arms (46%) were assessed between 12 and 24 months after surgery. Seventy percent of the group (n = 54) were able to extend their elbow against gravity (grade 3 of 5 or greater) following surgery. Seventy-nine percent of those with hamstring grafts achieved grade 3 of 5 or more compared with 77% with tibialis anterior and 33% with synthetic grafts. There was a statistically significant difference in postsurgery elbow extension between the tibialis anterior group and the synthetic graft group and the hamstring and the synthetic graft group but not between the tibialis anterior and the hamstring group. Complications occurred in 19 arms (14%), the majority occurring immediately after surgery and associated with the wounds. The remaining complications were with the synthetic graft group in which dehiscence of the proximal attachment occurred in 30% of the arms. Autologous tendon grafting is associated with achievement of antigravity elbow extension in a greater proportion of individuals than with prosthetic grafting. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Neutralizing Antibodies and Pathogenesis of Hepatitis C Virus Infection

    Directory of Open Access Journals (Sweden)

    Françoise Stoll-Keller

    2012-10-01

    Full Text Available Hepatitis C virus (HCV infection is a major cause of chronic liver disease worldwide. The interplay between the virus and host innate and adaptive immune responses determines the outcome of infection. There is increasing evidence that host neutralizing responses play a relevant role in the resulting pathogenesis. Furthermore, viral evasion from host neutralizing antibodies has been revealed to be an important contributor in leading both to viral persistence in acute liver graft infection following liver transplantation, and to chronic viral infection. The development of novel model systems to study HCV entry and neutralization has allowed a detailed understanding of the molecular mechanisms of virus-host interactions during antibody-mediated neutralization. The understanding of these mechanisms will ultimately contribute to the development of novel antiviral preventive strategies for liver graft infection and an urgently needed vaccine. This review summarizes recent concepts of the role of neutralizing antibodies in viral clearance and protection, and highlights consequences of viral escape from neutralizing antibodies in the pathogenesis of HCV infection.

  17. Determining the degree of grafting for poly (vinylidene fluoride) graft-copolymers using fluorine elemental analysis

    International Nuclear Information System (INIS)

    Yu Yang; Zhang Bowu; Yang Xuanxuan; Deng Bo; Li Linfan; Yu Ming; Li Jingye

    2011-01-01

    Acrylic acid (AAc) and styrene (St) were grafted onto poly (vinylidene fluoride) (PVDF) powder or membrane samples by pre-irradiation graft copolymerization. The grafted chains were proved by FT-IR spectroscopy analysis. The degree of grafting (DG) of the grafted PVDF was determined by fluorine elemental analysis (FEA) method, and was compared with the DGs determined by weighing method, acid-base back titration method and quantitative FT-IR method. The results show that the FEA method is accurate, convenient and universal, especially for the grafted polymer powders. (authors)

  18. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  19. Graft failure following bone marrow transplantation for severe aplastic anemia risk factors and treatment results

    NARCIS (Netherlands)

    Champlin, R.E.; Horowitz, M.M.; Bekkum, D.W. van; Camitta, B.M. Elfenbein, G.E.; Gale, R.P.; Gluckman, E.; Good, R.A.; Rimm, A.A. Rozman, C.; Speck, B. Bortin, M.M

    1989-01-01

    Graft failure was analyzed in 625 patients receiving allogeneic bone marrow transplants from HLA-identical sibling donors as treatment for severe aplastic anemia. Sixty-eight (11%) had no or only transient engraftment. Second bone marrow transplants were successful in achieving extended survival in

  20. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    Science.gov (United States)

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  1. Feature Hepatitis: Hepatitis Can Strike Anyone

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Feature Hepatitis Hepatitis Can Strike Anyone Past Issues / Spring 2009 Table ... from all walks of life are affected by hepatitis, especially hepatitis C, the most common form of ...

  2. A grafting from approach to graft polystyrene chains at the surface of graphene nanolayers by RAFT polymerization: Various graft densities from hydroxyl groups

    Energy Technology Data Exchange (ETDEWEB)

    Roghani-Mamaqani, Hossein, E-mail: r.mamaghani@sut.ac.ir [Department of Polymer Engineering, Sahand University of Technology, PO Box 51335-1996, Tabriz (Iran, Islamic Republic of); Khezri, Khezrollah [School of Chemistry, University College of Science, University of Tehran, PO Box 14155-6455, Tehran (Iran, Islamic Republic of)

    2016-01-01

    Graphical abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. - Highlights: • A RAFT agent grafted GO was used in grafting from RAFT polymerization of styrene. • The efficiency of RAFT agent attachment at the surface of GO is 41.12% for high density sample. • Polystyrene molecular weight is decreased by the addition of graphene content and also graft density of RAFT agent. - Abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. Grafting of APTES and RA was approved by Fourier transform infrared spectroscopy, X-ray photo electron spectroscopy, and Raman spectroscopy. Expansion of graphene interlayer by oxidation and functionalization processes was evaluated by X-ray diffraction. Conversion values of styrene were calculated using gas chromatography. Molecular weight and PDI values of attached polystyrene (PS) chains were studied by size exclusion chromatography. Thermogravimetric analysis was also used to investigate the degradation temperatures, char contents, and graft contents of modifiers and PS chains. GOHRH and GOHRL reach to char content of 55.3 and 45.2% at 600 °C, which shows that weight ratio of modifier (APTES and RA moieties) is 15.3 and 5.2%, respectively. Scanning and transmission electron microscopies show that

  3. Prevention of organ rejection in renal and liver transplantation with extended release tacrolimus

    Directory of Open Access Journals (Sweden)

    Reschen ME

    2014-09-01

    Full Text Available Michael E Reschen, Christopher A O’Callaghan Henry Wellcome Building, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom Abstract: Tacrolimus is the key immunosuppressant used to prevent allograft rejection in kidney and liver transplant recipients. Despite the efficacy of tacrolimus and adjunctive immunosuppressants, a substantial number of patients experience episodes of acute rejection and late graft loss. Nonadherence is an etiological factor in both acute rejection and graft loss. In 2007, a prolonged release version of tacrolimus became available that allows once daily administration, thus halving the pill burden compared to the standard twice-daily tacrolimus. An increasing number of studies in de novo transplantation and in treatment conversion have evaluated the pharmacokinetic profile, efficacy, and safety of prolonged-release tacrolimus. We have reviewed the literature on the use of prolonged-release tacrolimus and hope that this will be of value in the design of protocols for transplant immunosuppression.Keywords: immunosuppression, kidney, hepatic, allograft, adherence

  4. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  5. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  6. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Disease Type 1 (von Gierke) Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy ( ... Disease Type 1 (von Gierke) Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy ( ...

  7. Liver transplantation for severe hepatic trauma: Experience from a single center

    Institute of Scientific and Technical Information of China (English)

    Spiros G Delis; Andreas Bakoyiannis; Gennaro Selvaggi; Debbie Weppler; David Levi; Andreas G Tzakis

    2009-01-01

    Liver transplantation has been reported in the literature as an extreme intervention in cases of severe and complicated hepatic trauma. The main indications for liver transplant in such cases were uncontrollable bleeding and postoperative hepatic insufficiency. We here describe four cases of orthotopic liver transplantation after penetrating or blunt liver trauma. The indications were liver failure, extended liver necrosis, liver gangrene and multiple episodes of gastrointestinal bleeding related to portal hypertension, respectively. One patient died due to postoperative cerebral edema. The other three patients recovered well and remain on immunosuppression. Liver transplantation should be considered as a saving procedure in severe hepatic trauma, when all other treatment modalities fail.

  8. Determination of the distribution of graft yields following a radiation-induced graft copolymerization

    International Nuclear Information System (INIS)

    Schipschack, K.; Wagner, H.; Sawtschenko, L.

    1976-01-01

    In the radiation-induced graft copolymerization on solid initial polymers a distribution of graft yields takes place along the cross-sections of samples. Methods for determining this distribution, which are described in the literature, are reviewed. In our own investigations boards made of ethylene-vinyl acetate copolymers and grafted with vinyl chloride were used. Distributions of the grafted component obtained by infrared analysis of microtome cuts parallel to the surface are partly rather inhomogeneous, and are interpreted as dependent on the experimental parameters. (author)

  9. Study on grafting glycidyl methacrylate onto HDPE membranes by pre-irradiation graft copolymerization

    International Nuclear Information System (INIS)

    Tong Long; Zu Jianhua; Liu Xinwen; Sun Guisheng; Yu Chunhui

    2006-01-01

    Glycidyl methacrylate (GMA) was grafted onto HDPE membranes by pre-irradiation method with 1.8 MeV E-beam and a kind of membranes having reactive epoxy groups was successfully synthesized. Effects of monomer concentration, reaction temperature and time and irradiation dose on the grafting yield were studied. Composition, thermo-property and surface morphology of the grafted membranes were studied by FTIR, DSC and Tapping-mode AFM, respectively. The FTIR measurements proved the synthesized copolymer is HDPE-g-GMA. The DSC results indicated the grafted HDPE's melting temperature (T m ) and heat of fusion (ΔH f ( HDPE) ) which was reduced with increasing grafting yield. The AFM images indicated that surface of the HDPE-g-GMA membranes was rougher than the virgin HDPE. (authors)

  10. Prevention of primary vascular graft infection with silver-coated polyester graft in a porcine model

    DEFF Research Database (Denmark)

    Gao, H; Sandermann, J; Prag, J

    2010-01-01

    To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model.......To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model....

  11. Inhibition of Listeria monocytogenes in Fresh Cheese Using Chitosan-Grafted Lactic Acid Packaging

    Directory of Open Access Journals (Sweden)

    Laura N. Sandoval

    2016-04-01

    Full Text Available A chitosan from biologically obtained chitin was successfully grafted with d,l-lactic acid (LA in aqueous media using p-toluenesulfonic acid as catalyst to obtain a non-toxic, biodegradable packaging material that was characterized using scanning electron microscopy, water vapor permeability, and relative humidity (RH losses. Additionally, the grafting in chitosan with LA produced films with improved mechanical properties. This material successfully extended the shelf life of fresh cheese and inhibited the growth of Listeria monocytogenes during 14 days at 4 °C and 22% RH, whereby inoculated samples with chitosan-g-LA packaging presented full bacterial inhibition. The results were compared to control samples and commercial low-density polyethylene packaging.

  12. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  13. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    OpenAIRE

    Fekete D.; Stéger-Máté M.; Bőhm V.; Balázs G.; Kappel N.

    2015-01-01

    The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós) in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.). The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol.) Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne). The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermel...

  14. A new grafting technique for tympanoplasty: tympanoplasty with a boomerang-shaped chondroperichondrial graft (TwBSCPG).

    Science.gov (United States)

    Dündar, Rıza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal

    2014-10-01

    The aim of this study was to introduce a new grafting technique in tympanoplasty that involves use of a boomerang-shaped chondroperichondrial graft (BSCPG). The anatomical and functional results were evaluated. A new tympanoplasty with boomerang-shaped chondroperichondrial graft (TwBSCPG) technique was used in 99 chronic otitis media patients with central or marginal perforation of the tympanic membrane and a normal middle ear mucosa. All 99 patients received chondroperichondrial cartilage grafts with a boomerang-shaped cartilage island left at the anterior and inferior parts. Postoperative follow-ups were conducted at months 1, 6, and 12. Preoperative and postoperative audiological examinations were performed and air-bone gaps were calculated according to the pure-tone averages (PTAs) of the patients. In the preoperative period, most (83.8%) air-bone gaps were ≥ 16 dB; after operating using the TwBSCPG technique, the air-bone gaps decreased to 0-10 dB in most patients (77.8%). In the TwBSCPG patients, the mean preoperative air-bone gap was 22.02 ± 6.74 dB SPL. Postoperatively, the mean postoperative air-bone gap was 8.70 ± 5.74 dB SPL. The TwBSCPG technique therefore decreased the postoperative air-bone gap compared to that preoperatively (p = 0.000, z = -8.645). At the 1-month follow-up, there were six graft perforations and one graft retraction. At the 6-month follow-up, there were nine graft perforations and three graft retractions. At 12 months, there were seven graft perforations and four graft retractions. During the first year after the boomerang tympanoplasty surgery, graft lateralization was not detected in any patient. Retractions were grade 1 according to the Sade classification and were localized to the postero-superior quadrant of the tympanic membrane. The TwBSCPG technique has benefits with respect to postoperative anatomical and audiological results. It prevents perforation of the tympanic membrane at the anterior quadrant and avoids graft

  15. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  16. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  17. Impact of bone graft harvesting techniques on bone formation and graft resorption

    DEFF Research Database (Denmark)

    Saulacic, Nikola; Bosshardt, Dieter D; Jensen, Simon S

    2015-01-01

    BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone fo......: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption.......BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone...... formation and graft resorption in vivo. MATERIAL AND METHODS: Four harvesting techniques were used: (i) corticocancellous blocks particulated by a bone mill; (ii) bone scraper; (iii) piezosurgery; and (iv) bone slurry collected from a filter device upon drilling. The grafts were placed into bone defects...

  18. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  19. Hepatic Arterial Configuration in Relation to the Segmental Anatomy of the Liver; Observations on MDCT and DSA Relevant to Radioembolization Treatment

    International Nuclear Information System (INIS)

    Hoven, Andor F. van den; Leeuwen, Maarten S. van; Lam, Marnix G. E. H.; Bosch, Maurice A. A. J. van den

    2015-01-01

    PurposeCurrent anatomical classifications do not include all variants relevant for radioembolization (RE). The purpose of this study was to assess the individual hepatic arterial configuration and segmental vascularization pattern and to develop an individualized RE treatment strategy based on an extended classification.MethodsThe hepatic vascular anatomy was assessed on MDCT and DSA in patients who received a workup for RE between February 2009 and November 2012. Reconstructed MDCT studies were assessed to determine the hepatic arterial configuration (origin of every hepatic arterial branch, branching pattern and anatomical course) and the hepatic segmental vascularization territory of all branches. Aberrant hepatic arteries were defined as hepatic arterial branches that did not originate from the celiac axis/CHA/PHA. Early branching patterns were defined as hepatic arterial branches originating from the celiac axis/CHA.ResultsThe hepatic arterial configuration and segmental vascularization pattern could be assessed in 110 of 133 patients. In 59 patients (54 %), no aberrant hepatic arteries or early branching was observed. Fourteen patients without aberrant hepatic arteries (13 %) had an early branching pattern. In the 37 patients (34 %) with aberrant hepatic arteries, five also had an early branching pattern. Sixteen different hepatic arterial segmental vascularization patterns were identified and described, differing by the presence of aberrant hepatic arteries, their respective vascular territory, and origin of the artery vascularizing segment four.ConclusionsThe hepatic arterial configuration and segmental vascularization pattern show marked individual variability beyond well-known classifications of anatomical variants. We developed an individualized RE treatment strategy based on an extended anatomical classification

  20. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  1. Depth of the graft bed influences split-skin graft contraction.

    NARCIS (Netherlands)

    Mensik, I.; Lamme, E.N.; Brychta, P.

    2003-01-01

    Contraction of a split-thickness skin graft used for coverage of large defects remains a great problem in plastic, burn and reconstructive surgery. In this study we evaluated healing of split-thickness skin grafts transplanted in wounds on the subcutaneous fat and muscle fascia in pigs. Four young

  2. Hepatitis C

    Science.gov (United States)

    ... Workshops Follow Us Home Health Information Liver Disease Hepatitis (Viral) Hepatitis C Related Topics English English Español Section Navigation Hepatitis (Viral) What Is Viral Hepatitis? Hepatitis A Hepatitis B ...

  3. Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts

    International Nuclear Information System (INIS)

    Berggren, A.; Weiland, A.J.; Ostrup, L.T.

    1982-01-01

    Researchers studied the value of bone scintigraphy in the assessment of anastomotic patency and bone-cell viability in free bone grafts revascularized by microvascular anastomoses in twenty-seven dogs. The dogs were divided into three different groups, and scintigraphy was carried out using technetium-labeled methylene diphosphonate in composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and periosteal grafts placed in different recipient beds. The viability of the grafts were evaluated by histological examination and fluorescence microscopy after triple labeling with oxytetracycline on the first postoperative day, alizarin complexone on the fourth postoperative day, and DCAF on the eleventh postoperative day. A positive scintiscan within the first week following surgery indicated patent microvascular anastomoses, and histological study and fluorescence microscopy confirmed that bone throughout the graft was viable. A positive scintiscan one week after surgery or later does not necessarily indicate microvascular patency or bone-cell survival, because new bone formed by creeping substitution on the surface of a dead bone graft can result in this finding

  4. De novo hepatic steatosis drives atherogenic risk in liver transplantation recipients.

    Science.gov (United States)

    Idowu, Michael O; Chhatrala, Ravi; Siddiqui, M Bilal; Driscoll, Carolyn; Stravitz, R Todd; Sanyal, Arun J; Bhati, Chandra; Sargeant, Carol; Luketic, Velimir A; Sterling, Richard K; Contos, Melissa; Matherly, Scott; Puri, Puneet; Siddiqui, M Shadab

    2015-11-01

    Nonalcoholic fatty liver disease is associated with cardiovascular disease (CVD) in the general population. Despite a high prevalence of de novo hepatic steatosis after liver transplantation (LT), there are no data exploring the association between hepatic steatosis after LT and atherogenic risk. The aim of the study was to explore the impact of hepatic steatosis on serum atherogenic markers in liver transplantation recipients (LTRs). Biomarkers of CVD risk were compared in 89 LTRs with no known history of dyslipidemia, ischemic heart disease, or graft cirrhosis. To avoid potential confounders, LTRs on oral hypoglycemic agents, exogenous insulin, corticosteroids, or lipid-lowering therapy were excluded. Only patients for whom histological assessment was available after LT were included in the study. Thirty-five LTRs had de novo hepatic steatosis after LT, whereas 54 did not. Both cohorts were similar with regards to age, sex, ethnicity, and follow-up from LT. Additionally, the traditional lipid profile was similar between the 2 cohorts. LTRs with hepatic steatosis had higher serum concentrations of small-dense low-density lipoprotein cholesterol (sdLDL-C; 34.8 ± 16.9 versus 22.7 ± 11.2 mg/dL; P hepatic steatosis had higher serum insulin concentrations (27.8 ± 41.8 versus 11.7 ± 7.8 uU/mL; P Steatosis grade was directly related to sdLDL-C, sdLDL-P, insulin, VLDL-P, and VLDL-size. In multivariate analysis, the association between steatosis grade and sdLDL-C (β = 0.03; P = 0.029), VLDL-size (β = 0.316; P = 0.04), and low-density lipoprotein particle size (β = -0.27; P = 0.05) was independent of sex, body mass index, age, diabetes mellitus, time from transplant, and indication for LT. In conclusion, de novo hepatic steatosis after LT is associated with atherogenic lipoproteins and independent of traditional CVD risk factors. © 2015 American Association for the Study of Liver Diseases.

  5. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  6. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  7. Hydrophilic/hydrophobic character of grafted cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E., E-mail: takacs@iki.kfki.h [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Wojnarovits, L. [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Borsa, J. [Budapest University of Technology and Economics (Hungary); Racz, I. [Bay Zoltan Institute for Materials Science and Technology, Budapest (Hungary)

    2010-04-15

    Vinyl monomers with long paraffin chains were grafted onto two kinds of cellulose (cotton and cotton linter) by direct irradiation grafting technique. The effect of dose, monomer structure and concentration, as well as homopolymer suppressor (styrene) concentration on the grafting yield was studied and the optimal grafting conditions were established. Grafting decreased the swelling of the samples in water and increased their polymer compatibility in polypropylene matrix.

  8. Hepatitis A through E (Viral Hepatitis)

    Science.gov (United States)

    ... Treatment Eating, Diet, & Nutrition Clinical Trials Wilson Disease Hepatitis (Viral) View or Print All Sections What is Viral Hepatitis? Viral hepatitis is an infection that causes liver inflammation ...

  9. Control of lipid oxidation by nonmigratory active packaging films prepared by photoinitiated graft polymerization.

    Science.gov (United States)

    Tian, Fang; Decker, Eric A; Goddard, Julie M

    2012-08-08

    Transition metal-promoted oxidation impacts the quality, shelf life, and nutrition of many packaged foods. Metal-chelating active packaging therefore offers a means to protect foods against oxidation. Herein, we report the development and characterization of nonmigratory metal-chelating active packaging. To prepare the films, carboxylic acids were grafted onto the surfaces of polypropylene films by photoinitiated graft polymerization of acrylic acid. Attenuated total reflectance/Fourier transform infrared spectroscopy, contact angle, scanning electron microscopy, and iron-chelating assay were used to characterize film properties. Graft polymerization yielded a carboxylic acid density of 68.67 ± 9.99 nmol per cm(2) film, with ferrous iron-chelating activity of 71.07 ± 12.95 nmol per cm(2). The functionalized films extended the lag phase of lipid oxidation in a soybean oil-in-water emulsion system from 2 to 9 days. The application of such nonmigratory active packaging films represents a promising approach to reduce additive use while maintaining food quality.

  10. Recipient But Not Donor Adiponectin Polymorphisms Are Associated With Early Posttransplant Hepatic Steatosis in Patients Transplanted for Non-Nonalcoholic Fatty Liver Disease Indications.

    Science.gov (United States)

    John, Binu V; Aiken, Taylor; Garber, Ari; Thomas, Dawn; Lopez, Rocio; Patil, Deepa; Konjeti, Venkata Rajesh; Fung, John J; McCollough, Arthur J; Askar, Medhat

    2018-06-01

    De novo steatosis after liver transplant is common and can occur in up to one-third of patients who are transplanted for liver disease other than for nonalcoholic fatty liver disease. Genetic factors may influence posttransplant steatosis; in a posttransplant setting, donor or recipient genetic factors could also play roles. Genetic polymorphisms in the adiponectin gene have been associated with metabolic syndrome in the pretransplant setting. We aimed to assess the association between donor and recipient adiponectin polymorphisms and early posttransplant hepatic steatosis identified on liver biopsies. Clinical data were collected for 302 liver transplant patients who underwent protocol biopsies for hepatitis C. Of these, 111 patients had available biopsies and donor/recipient DNA. Patients with grade 1 steatosis or greater (35% of patients) were compared with patients without posttransplant steatosis with respect to clinical features and donor/recipient adiponectin polymorphism genotypes. Patients who developed posttransplant steatosis and those without steatosis were similar with respect to individual components of metabolic syndrome. The adiponectin polymorphisms rs1501299 G/G and rs17300539 G/G genotypes in recipients were associated with early posttransplant graft steatosis. We found no associations between graft steatosis and donor adiponectin polymorphisms. Genetic polymorphisms in the adiponectin gene of recipients (but not donors) are associated with early de novo posttransplant hepatic steatosis, independent of components of metabolic syndrome.

  11. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  12. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    Science.gov (United States)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-06-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time.

  13. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    International Nuclear Information System (INIS)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-01-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time

  14. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  15. Hepatitis isquémica Ischemic hepatitis

    Directory of Open Access Journals (Sweden)

    Marcos Amuchástegui (h

    2006-10-01

    Full Text Available La hepatitis isquémica es una complicación sumamente infrecuente de cirugía cardiovascular. Las biopsias muestran necrosis centrolobulillar. El término de "hepatitis" fue propuesto debido al aumento de transaminasas similar a aquellas de origen infeccioso, e "isquémica" por falla en la perfusión hepática. Posteriormente se definió el término de hepatitis isquémica como cuadro de elevación aguda y reversible (dentro de las 72 horas de transaminasas de hasta 20 veces el valor normal, asociado a trastornos en la perfusión hepática, luego de haber excluido otras causas de hepatitis aguda o daño hepatocelular. Se describe el caso de un paciente de 53 años que consulta por dolor epigástrico de 12 h de evolución sin fiebre, náuseas ni vómitos, resistente a la medicación. Tenía antecedentes inmediatos de reemplazo de válvula aórtica, y estaba anticoagulado. Evolucionó con shock y fallo multiorgánico. El examen evidenció marcada ictericia y signos de taponamiento pericárdico, asociado a un aumento considerable de enzimas hepáticas. Un ecocardiograma informó signos de taponamiento cardíaco y ausencia de disección aórtica. Se decidió pericardiocentesis, extrayéndose 970 cc. de líquido sanguinolento, y hemodiálisis, con notable mejoría de su estado hemodinámico. Los valores enzimáticos disminuyeron. Los marcadores virales fueron negativos.Ischemic hepatitis is an uncommon cardiovascular surgery complication. Hepatic biopsies show centrolobulillar necrosis. The term "hepatitis" was proposed because of a raise in hepatic enzymes similar with infectious disease, and "ischemic" because of failure in hepatic perfusion. Ischemic hepatitis was then defined as an acute and reversible elevation of hepatic enzymes (within 72 h, associated with disturbance in hepatic perfusion after excluding other causes of acute hepatitis. A 53 year-old male presented complaining of a 12 h epigastric pain, without nausea or vomiting, resistant

  16. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  17. Living-related liver transplantation for patients with fulminant and subfulminant hepatic failure.

    Science.gov (United States)

    Miwa, S; Hashikura, Y; Mita, A; Kubota, T; Chisuwa, H; Nakazawa, Y; Ikegami, T; Terada, M; Miyagawa, S; Kawasaki, S

    1999-12-01

    The prognosis for patients with fulminant (FHF) or subfulminant hepatic failure (SFHF) has improved since the introduction of liver transplantation. However, the death rate of patients awaiting liver transplantation is high, possibly because of the difficulty in obtaining grafts in a timely manner, given the relative shortage of cadaveric donors. Between June 1990 and June 1999, 106 patients underwent living-related liver transplantation (LRLT) at Shinshu University Hospital. Among them, 8 patients had FHF and 6 had SFHF; these 14 patients are the subjects of this report. The graft volumes (GV) ranged from 231 mL to 625 mL, corresponding to 35% to 105% of the recipients' standard liver volume (SLV). The postoperative courses of all donors were uneventful. Following liver transplantation, all grafts functioned favorably, with normalization of serum total bilirubin within 3 to 5 days and normalization of coagulation profiles within 4 to 7 days. Thirteen of the 14 recipients are still alive. The actuarial 6-month, 1-year, and 5-year survival rates were 100%, 90%, and 90%, respectively. In the present study, when the ratio of the GV to the recipient's SLV was more than 35%, the graft was able to support the patient's metabolic demand after liver transplantation for FHF or SFHF. Because of the urgent nature of liver transplantation in this clinical condition, concerns over informed consent may be even greater than for elective LRLT. Nevertheless, the high success rate and low donor risk may justify this option for pediatric patients, as well as for a limited population of adult patients suffering from FHF or SFHF.

  18. Environmental application of radiation grafting

    International Nuclear Information System (INIS)

    Tamada, Masao

    2007-01-01

    Adsorbent having high selectivity against a certain metal ion was synthesized by means of radiation-induced graft polymerization for the purpose of environmental application. The resulting adsorbents were utilized for the removal of toxic metal from scallop waste and the collection of uranium from seawater. As a novel application of grafting, the biodegradability of poly-hydroxybutylate was controlled by grafting. The biodegradability could be depressed by the graft chain and then recovered by external stimuli such as thermal and chemical treatments. (author)

  19. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  20. Graft-copolymerization onto carbon black

    International Nuclear Information System (INIS)

    Nakase, Yoshiaki; Nishii, Masanobu; Kijima, Toshiyuki; Kato, Hiroshi.

    1988-07-01

    Radiation-induced graft copolymerization of vinyl monomer onto carbon black was performed. During the γ-ray- and electron beam-induced polymerization (In-source), or the electron beam post-polymerization, the graft-copolymerization behavior was affected by the kinds of both carbon blacks and monomers, i.e. the smaller the size of carbon black particles, the higher the apparent grafted fraction. Homopolymer in the grafted carbon black samples was washed out by the solvent of the polymer, and the extracted polymer seemed to be dimer or trimer of the used monomer. In the case of the post-polymerization with the pre-irradiation doses of 50 Mrad, homopolymer was hardly observed. The polymer sheets of plastics or rubbers with grafted carbon black had an electrical conductivity unalterable considerably by the heating cycles. The particles of grafted carbon black in the sheet might be kept much more at the surface layer within 100 nm depth than at the inner layer. (author)

  1. FAS grafted superhydrophobic ceramic membrane

    Science.gov (United States)

    Lu, Jun; Yu, Yun; Zhou, Jianer; Song, Lixin; Hu, Xingfang; Larbot, Andre

    2009-08-01

    The hydrophobic properties of γ-Al 2O 3 membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 °C) of the fluoroalkylsilane grafted on Al 2O 3 powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and γ-Al 2O 3 membrane surface as well as the formed surface morphology.

  2. Radiation-induced grafting of TMPM onto polypropylene

    International Nuclear Information System (INIS)

    Wang Huiliang; Li Hong; Chen Wenxiu

    1995-01-01

    The gamma radiation-induced graft copolymerization of 2,2,6,6-tetramethyl-4-piperidinyl-methacrylate (TMPM), a very effective hindered amine light stabilizer (HALS), onto polypropylene was investigated by simultaneous- irradiation technique. The various synthesis conditions on the graft content was studied. It was found that benzene, CCl 4 and petroleum ether are more effective than other solvents, the percent grafting reached 7.1% for benzene. The percent grafting is higher when graft copolymerization is carried out in argon atmosphere than those in air. For all the grafting copolymerization carried out in benzene and CCl 4 , percent grafting increase linearly from 1 to 5 Mrad and beyond 5 Mrad, a tendency to level off appeared. At a constant dose, the percent grafting was found to be higher at high dose rate until 228 rad/s. Percent grafting also increased continuously with increasing monomer concentration up to 2.85 mol/L, but significant increase in grafting was observed only up to 1.14 mol/L

  3. Salt-Induced Control of the Grafting Density in Poly(ethylene glycol) Brush Layers by a Grafting-to Approach

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Olsen, Stefan; Thormann, Esben

    2018-01-01

    In this work, a method to obtain control of the grafting density during the formation of polymer brush layers by the grafting-to method of thiolated poly(ethylene glycol) onto gold is presented. The grafting density of the polymer chains was adjusted by adding Na2SO4 in concentrations between 0.......2 and 0.9 M to the aqueous polymer solution during the grafting process. The obtained grafting densities ranged from 0.26 to 1.60 chains nm-2, as determined by surface plasmon resonance. The kinetics of the grafting process were studied in situ by a quartz crystal microbalance with dissipation......, and a mushroom to brush conformational transition was observed when the polymer was grafted in the presence of Na2SO4. The transition from mushroom to brush was only observed for long periods of grafting, highlighting the importance of time to obtain high grafting densities. Finally, the prepared brush layer...

  4. Studies on radiation-induced graft polymerization

    International Nuclear Information System (INIS)

    Omichi, Hideki

    1978-09-01

    Radiation-induced graft polymerization is used extensively to improve physical properties of polymers, but few processes are now commercialized. The reason for this is partly inadequate basic research on the reaction and partly the difficulty in developing the grafting process with large radiation source. Firstly, new techniques are proposed of studying kinetics of the graft polymerization in heterogeneous system. Based on the grafting yield, the molecular weight of graft chains, and the amount of radicals given by ESR and activation analysis, kinetic parameters are obtained and the reaction mechanism of grafting process is discussed. Secondly, the development of grafting process of poly (vinyl chloride)-butadiene is described. By study of the reaction, process design, construction and operation of the pilot plant, and economic analysis of the process, this process with 60 Co gamma ray sources is shown to be industrially promising. (author)

  5. An Investigation of Proton Conductivity of Vinyltriazole-Grafted PVDF Proton Exchange Membranes Prepared via Photoinduced Grafting

    Directory of Open Access Journals (Sweden)

    Sinan Sezgin

    2014-01-01

    Full Text Available Proton exchange membrane fuel cells (PEMFCs are considered to be a promising technology for clean and efficient power generation in the twenty-first century. In this study, high performance of poly(vinylidene fluoride (PVDF and proton conductivity of poly(1-vinyl-1,2,4-triazole (PVTri were combined in a graft copolymer, PVDF-g-PVTri, by the polymerization of 1-vinyl-1,2,4-triazole on a PVDF based matrix under UV light in one step. The polymers were doped with triflic acid (TA at different stoichiometric ratios with respect to triazole units and the anhydrous polymer electrolyte membranes were prepared. All samples were characterized by FTIR and 1H-NMR spectroscopies. Their thermal properties were examined by thermogravimetric analysis (TGA and differential scanning calorimetry (DSC. TGA demonstrated that the PVDF-g-PVTri and PVDF-g-PVTri-(TAx membranes were thermally stable up to 390°C and 330°C, respectively. NMR and energy dispersive X-ray spectroscopy (EDS results demonstrated that PVDF-g-PVTri was successfully synthesized with a degree of grafting of 21%. PVDF-g-PVTri-(TA3 showed a maximum proton conductivity of 6×10-3 Scm−1 at 150°C and anhydrous conditions. CV study illustrated that electrochemical stability domain for PVDF-g-PVTri-(TA3 extended over 4.0 V.

  6. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Related Liver Disease Alpha-1 Antitrypsin Deficiency Autoimmune Hepatitis Benign Liver Tumors Biliary Atresia Cirrhosis of the ... Disease Type 1 (von Gierke) Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Intrahepatic Cholestasis of ...

  7. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy (ICP) Jaundice In Newborns ... are the common causes of cirrhosis? Hepatitis B & C Alcohol-related Liver Disease Non-alcoholic Fatty Liver ...

  8. Development of Highly Efficient Grafting Technique and Synthesis of Natural Polymer-Based Graft Adsorbent

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Y; Seko, N; Tamada, M [Japan Atomic Energy Agency, Quantum Beam Science Directorate, Takasaki (Japan)

    2012-09-15

    In the framework of the CRP, Japan has focused on the development of fibrous adsorbents for removal of toxic metal ions and recovery of significant metal ions from industrial wastewater and streaming water. Graft polymerization was carried out by using gamma irradiation facility and electron beam accelerator. Emulsion grafting is a novel topic for synthesis of metal ion adsorbents which are prepared from fibrous trunk polymers such as polyethylene fibre and biodegradable nonwoven fabrics. The emulsion grafting, where monomer micelles are dispersed in water in the presence of surfactant, is a highly efficient and economic grafting technique as compared to general organic solvent system. The resultant cotton-based adsorbent has high adsorption efficiency and high adsorption capacity for Hg, besides, it is biodegradable. Polylactic acid can also be used as a trunk material for the grafting. (author)

  9. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... 1 (von Gierke) Hemochromatosis Hepatic Encephalopathy Hepatitis A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy (ICP) Jaundice ... diseases. What are the common causes of cirrhosis? Hepatitis B & C Alcohol-related Liver Disease Non-alcoholic Fatty ...

  10. An outbreak of hepatitis A among primary and secondary contacts of an international adoptee.

    Science.gov (United States)

    Pelletier, Andrew R; Mehta, Puja J; Burgess, Donald R; Bondeson, Lisa M; Carson, Patty J; Rea, Vicki E; Sharapov, Umid M; Hu, Dale J

    2010-01-01

    The Advisory Committee on Immunization Practices recommends that susceptible people traveling to developing countries receive hepatitis A vaccine or immune globulin prior to departure. Until 2009, the recommendations did not address non-traveling family members or other close contacts of international adoptees. We report an outbreak of hepatitis A in 2008 that occurred in Maine. Eight members of an extended family developed hepatitis A following the arrival of an asymptomatic infant from Ethiopia who was brought to the United States by an adoption agency. Two children in the family attended an elementary school where five additional cases of hepatitis A were subsequently identified. Only three (1%) of 208 students at the school had previously been immunized against hepatitis A. This outbreak highlights the need to immunize household members and other close contacts of families adopting children from countries where hepatitis A is endemic, as well as all children at one year of age.

  11. Design of a Sapling Branch Grafting Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available The automatic sapling grafting methods and grafting robot technologies are not comprehensively studied despite the fact that they are urgently required in practice. For this reason, a sapling grafting robot is developed to implement automatic grafting for saplings. The developed grafting robot includes clipping mechanism, moving mechanism, cutting mechanism, binding mechanism, and Arduino MCU based control system, which is capable of clipping, moving, positioning, cutting, grafting, and binding saplings. Experiments show that the stock cutting efficiency is 98.4%, the scion cutting efficiency is 98.9%, the grafting efficiency is 87.3%, and the binding efficiency is 68.9%.

  12. Fat Grafting for Facial Filling and Regeneration.

    Science.gov (United States)

    Coleman, Sydney R; Katzel, Evan B

    2015-07-01

    Plastic surgeons have come to realize that fat grafting can rejuvenate an aging face by restoring or creating fullness. However, fat grafting does much more than simply add volume. Grafted fat can transform or repair the tissues into which it is placed. Historically, surgeons have hesitated to embrace the rejuvenating potential of fat grafting because of poor graft take, fat necrosis, and inconsistent outcomes. This article describes fat grafting techniques and practices to assist readers in successful harvesting, processing, and placement of fat for optimal graft retention and facial esthetic outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Determination of grafting conversion degree in PS/PS-graft-POSS/POSS hybrid nanocomposites obtained through reactive processing

    International Nuclear Information System (INIS)

    Bianchi, Otavio; Repenning, Gustavo B.; Mauler, Raquel S.; Oliveira, Ricardo V.B.; Canto, Leonardo B.

    2011-01-01

    Hybrid nanocomposites of polystyrene (PS) and polyhedral oligomeric silsesquioxanes (POSS) - PS/PS-graft-POSS/POSS - with different grafting degrees were prepared by reactive melt processing using dicumyl peroxide (DCP) as initiator in the presence or absence of styrene monomer as radical transfer agent. Gel permeation chromatography (GPC) using triple-detector and proton nuclear magnetic resonance (NMR 1 H) analyses were used together to determine the conversion degree of PS-graft-POSS as a function of the reactive processing conditions adopted. GPC was employed to evaluate the effects of grafting (PS-graft-POSS) and PS chains degradation (β scission) that occur simultaneously during processing on the variation of average molecular masses and distributions for each PS/POSS sample. PS/POSS systems processed with styrene showed higher weight average molecular weights (M w ) and lower polydispersity indexes (M w /M n ), as a result of higher grafting (PS-graft-POSS) conversion (28-40%) and lower PS chain degradation level, as compared to PS/POSS systems processed without styrene in which the degree of grafting conversion was around 25-28%. (author)

  14. Prevalence of hepatitis A virus, hepatitis B virus, hepatitis C virus, hepatitis D virus and hepatitis E virus as causes of acute viral hepatitis in North India: a hospital based study.

    Science.gov (United States)

    Jain, P; Prakash, S; Gupta, S; Singh, K P; Shrivastava, S; Singh, D D; Singh, J; Jain, A

    2013-01-01

    Acute viral hepatitis (AVH) is a major public health problem and is an important cause of morbidity and mortality. The aim of the present study is to determine the prevalence of hepatitis A virus (HAV), hepatitis B virus (HBV), hepatitis C virus (HCV), hepatitis D virus (HDV) and hepatitis E virus (HEV) as causes of AVH in a tertiary care hospital of North India. Blood samples and clinical information was collected from cases of AVH referred to the Grade I viral diagnostic laboratory over a 1-year period. Samples were tested for hepatitis B surface antigen, anti-HCV total antibodies, anti-HAV immunoglobulin M (IgM) and anti-HEV IgM by the enzyme-linked immunosorbent assay. PCR for nucleic acid detection of HBV and HCV was also carried out. Those positive for HBV infection were tested for anti-HDV antibodies. Fisher's exact test was used and a P hepatitis cases, 62 (23.22%) patients presented as acute hepatic failure. HAV (26.96%) was identified as the most common cause of acute hepatitis followed by HEV (17.97%), HBV (16.10%) and HCV (11.98%). Co-infections with more than one virus were present in 34 cases; HAV-HEV co-infection being the most common. HEV was the most important cause of acute hepatic failure followed by co-infection with HAV and HEV. An indication towards epidemiological shift of HAV infection from children to adults with a rise in HAV prevalence was seen. To the best of our knowledge, this is the first report indicating epidemiological shift of HAV in Uttar Pradesh.

  15. Hepatic transplantation outcomes for carefully selected cirrhotic patients with hepatocellular carcinoma: experience at a small- to medium-volume centre.

    LENUS (Irish Health Repository)

    Qasim, A

    2012-02-01

    BACKGROUND: Hepatic transplantation outcomes for cirrhotic patients with hepatocellular carcinoma (HCC) at a small- to medium-volume centre are not fully known due to relative novelty of patient selection criteria. AIM: To determine hepatic transplantation outcomes for HCC at a small- to medium-volume centre. Patients and methods Hepatocellular carcinoma patients were listed for transplantation according to the International Guideline and further categorized as those fulfilling or exceeding Milan or University of San Francisco (UCSF) criteria on explanted liver morphology. Outcomes including mortality, retransplantation, and tumour recurrence rate were analysed. RESULTS: Twenty-six patients had HCC and on explanted liver morphology, Milan and UCSF criteria met 15 and 18 patients, respectively. Patients and graft survival at 3 months, 1 and 5 years were 100, 96, 84, and 88, 84, 77%, respectively. Outcomes favoured Milan criteria but did not reach statistical significance. CONCLUSIONS: Hepatic transplantation for HCC at a small-to medium-volume transplant centre had comparable survival outcomes to high-volume centres.

  16. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  17. A study on the morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method

    International Nuclear Information System (INIS)

    Song, Ju-Myung; Ko, Beom-Seok; Sohn, Joon-Yong; Nho, Young Chang; Shin, Junhwa

    2014-01-01

    The morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method was investigated using DMA, DSC, XRD, and SAXS instruments. The DMA study indicates that the ETFE amorphous phase and PS amorphous phase are mixed well in the PS-grafted ETFE films while the ETFE crystalline phase and the PS amorphous phase are separated, suggesting that the PS chains are grafted mainly on the ETFE amorphous regions. The DSC and XRD data showed that the natural crystalline structures of ETFE in the grafted ETFE films are not affected by the degree of grafting. The SAXS profiles displayed that the inter-crystalline distance of the ETFE films increases with an increasing degree of grafting, which further implies that the PS graft chains formed by the simultaneous irradiation has a significant impact on the amorphous morphology of the resulting grafted ETFE film. Thus, these results indicate that the styrene monomers are mainly grafted on the ETFE amorphous regions during the simultaneous radiation grafting process. - Highlights: • PS-grafted ETFE films were prepared by a simultaneous radiation grafting method was investigated. • The natural crystalline structures of grafted ETFE films are not affect by the degree of grafting. • The inter-crystalline distance of the ETFE films increase with increasing degree of grafting. • The styrene monomers are mainly grafted on the ETFE amorphous regions during a simultaneous radiation grafting using gamma-ray

  18. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: early results.

    Science.gov (United States)

    Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong

    2012-11-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft

  19. FAS grafted superhydrophobic ceramic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Yu Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Zhou Jianer [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Song Lixin; Hu Xingfang [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Larbot, Andre [Institut Europeen des Membranes, UMR 5635-CNRS, ENSCM, UMII, 1919 Route de Mende 34293, Montpellier Cedex 5 (France)

    2009-08-30

    The hydrophobic properties of {gamma}-Al{sub 2}O{sub 3} membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 deg. C) of the fluoroalkylsilane grafted on Al{sub 2}O{sub 3} powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and {gamma}-Al{sub 2}O{sub 3} membrane surface as well as the formed surface morphology.

  20. Postoperative radiographic evaluation of vascularized fibular grafts

    International Nuclear Information System (INIS)

    Manaster, B.J.; Coleman, D.A.; Bell, D.A.

    1989-01-01

    This paper reports on thirty-five patients with free vascularized fibular grafts examined postoperatively with plain radiography. Early graft incorporation is seen as a fuzziness of the cortex at the site of its insertion into the host bone. Causes of failure in grafting for bone defects include graft fracture, hardware failure, and infection. A high percentage of complications or at least delayed unions occurred when vascularized fibular grafts were used to fill defects in the lower extremity. Conversely, upper extremity defects bridged by vascularized grafts heal quickly and hypertrophy. Vascularized grafts placed in the femoral head and neck for a vascular necrosis incorporate early on their superior aspect. The osseous tunnel in which they are placed is normally wider than the graft and often becomes sclerotic; this appearance does not represent nonunion

  1. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  2. Two-Stage Liver Transplantation with Temporary Porto-Middle Hepatic Vein Shunt

    Directory of Open Access Journals (Sweden)

    Giovanni Varotti

    2010-01-01

    Full Text Available Two-stage liver transplantation (LT has been reported for cases of fulminant liver failure that can lead to toxic hepatic syndrome, or massive hemorrhages resulting in uncontrollable bleeding. Technically, the first stage of the procedure consists of a total hepatectomy with preservation of the recipient's inferior vena cava (IVC, followed by the creation of a temporary end-to-side porto-caval shunt (TPCS. The second stage consists of removing the TPCS and implanting a liver graft when one becomes available. We report a case of a two-stage total hepatectomy and LT in which a temporary end-to-end anastomosis between the portal vein and the middle hepatic vein (TPMHV was performed as an alternative to the classic end-to-end TPCS. The creation of a TPMHV proved technically feasible and showed some advantages compared to the standard TPCS. In cases in which a two-stage LT with side-to-side caval reconstruction is utilized, TPMHV can be considered as a safe and effective alternative to standard TPCS.

  3. Emerging concepts in liver graft preservation

    Science.gov (United States)

    Bejaoui, Mohamed; Pantazi, Eirini; Folch-Puy, Emma; Baptista, Pedro M; García-Gil, Agustín; Adam, René; Roselló-Catafau, Joan

    2015-01-01

    The urgent need to expand the donor pool in order to attend to the growing demand for liver transplantation has obliged physicians to consider the use of suboptimal liver grafts and also to redefine the preservation strategies. This review examines the different methods of liver graft preservation, focusing on the latest advances in both static cold storage and machine perfusion (MP). The new strategies for static cold storage are mainly designed to increase the fatty liver graft preservation via the supplementation of commercial organ preservation solutions with additives. In this paper we stress the importance of carrying out effective graft washout after static cold preservation, and present a detailed discussion of the future perspectives for dynamic graft preservation using MP at different temperatures (hypothermia at 4 °C, normothermia at 37 °C and subnormothermia at 20 °C-25 °C). Finally, we highlight some emerging applications of regenerative medicine in liver graft preservation. In conclusion, this review discusses the “state of the art” and future perspectives in static and dynamic liver graft preservation in order to improve graft viability. PMID:25593455

  4. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  5. Failure to incriminate hepatitis B, hepatitis C, and hepatitis E viruses in the aetiology of fulminant non-A non-B hepatitis.

    OpenAIRE

    Mutimer, D; Shaw, J; Neuberger, J; Skidmore, S; Martin, B; Hubscher, S; McMaster, P; Elias, E

    1995-01-01

    Sporadic non-A, non-B hepatitis is the most common indication for liver transplantation in patients presenting with fulminant and subacute liver failure. This study used serological, histological, and molecular biological techniques to examine specimens from 23 consecutive patients transplanted for sporadic non-A, non-B hepatitis. No evidence was found of hepatitis C virus, hepatitis E virus, or 'cryptic' hepatitis B virus infection.

  6. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  7. Sequence diversity of hepatitis C virus 6a within the extended interferon sensitivity-determining region correlates with interferon-alpha/ribavirin treatment outcomes.

    Science.gov (United States)

    Zhou, Daniel X M; Chan, Paul K S; Zhang, Tiejun; Tully, Damien C; Tam, John S

    2010-10-01

    Studies on the association between sequence variability of the interferon sensitivity-determining region (ISDR) of hepatitis C virus and the outcome of treatment have reached conflicting results. In this study, 25 patients infected with HCV 6a who had received interferon-alpha/ribavirin combination treatment were analyzed for the sequence variations. 14 of them had the full genome sequences obtained from a previous study, whereas the other 11 samples were sequenced for the extended ISDR (eISDR). This eISDR fragment covers 192 bp (64 amino acids) upstream and 201 bp (67 amino acids) downstream from the ISDR previously defined for HCV 1b. The comparison between interferon-alpha resistance and response groups for the amino acid mutations located in the full genome (6 and 8 patients respectively) as well as the mutations located in the eISDR (10 and 15 patients respectively) showed that the mutations I2160V, I2256V, V2292I (Pc) 2010 Elsevier B.V. All rights reserved.

  8. Hepatitis

    Science.gov (United States)

    ... most common types of viral hepatitis. What Is Hepatitis A? For kids, hep A is the most common ... they recover, it does not come back. Can Hepatitis A Be Prevented? The following will help keep people ...

  9. Clinical and virological improvement of hepatitis B virus-related or hepatitis C virus-related chronic hepatitis with concomitant hepatitis A virus infection.

    Science.gov (United States)

    Sagnelli, Evangelista; Coppola, Nicola; Pisaturo, Mariantonietta; Pisapia, Raffaella; Onofrio, Mirella; Sagnelli, Caterina; Catuogno, Antonio; Scolastico, Carlo; Piccinino, Felice; Filippini, Pietro

    2006-06-01

    We evaluated the clinical and virological characteristics of hepatitis A virus infection in persons concomitantly infected with hepatitis B virus (HBV) or hepatitis C virus (HCV). We enrolled 21 patients with acute hepatitis A and chronic hepatitis with no sign of liver cirrhosis, 13 patients who were positive for hepatitis B surface antigen (case B group), 8 patients who were anti-HCV positive (case C group), and 21 patients with acute hepatitis A without a preexisting liver disease (control A group). Two control groups of patients with chronic hepatitis B (control B group) or C (control C group) were also chosen. All control groups were pair-matched by age and sex with the corresponding case group. Fulminant hepatitis A was never observed, and hepatitis A had a severe course in 1 patient in the case B group and in 1 patient in the control A group. Both patients recovered. On admission, HBV DNA was detected in 1 patient in the case B group (7.7%) and in 13 patients (50%) in the control B group; HCV RNA was found in no patient in the case C group and in 16 patients (81.2%) in the control C group. Of 9 patients in the case B group who were followed up for 6 months, 3 became negative for hepatitis B surface antigen and positive for hepatitis B surface antibody, 2 remained positive for hepatitis B surface antigen and negative for HBV DNA, and 4 became positive for HBV DNA with a low viral load [corrected] Of 6 patients in the case C group who were followed up for 6 months, 3 remained negative for HCV RNA, and 3 had persistently low viral loads. Concomitant hepatitis A was always self-limited, associated with a marked inhibition of HBV and HCV genomes, and possibly had a good prognosis for the underlying chronic hepatitis.

  10. Application of platelet-rich plasma and platelet-rich fibrin in fat grafting: basic science and literature review.

    Science.gov (United States)

    Liao, Han-Tsung; Marra, Kacey G; Rubin, J Peter

    2014-08-01

    Due to the natural properties of fat, fat grafting remains a popular procedure for soft tissue volume augmentation and reconstruction. However, clinical outcome varies and is technique dependent. Platelet-rich plasma (PRP) contains α-granules, from which multiple growth factors such as platelet-derived growth factor, transforming growth factor-β, vascular endothelial growth factor, and epidermal growth factor can be released after activation. In recent years, the scope of PRP therapies has extended from bone regeneration, wound healing, and healing of musculoskeletal injuries, to enhancement of fat graft survival. In this review, we focus on the definition of PRP, the different PRP preparation and activation methods, and growth factor concentrations. In addition, we discuss possible mechanisms for the role of PRP in fat grafting by reviewing in vitro studies with adipose-derived stem cells, preadipocytes, and adipocytes, and preclinical and clinical research. We also review platelet-rich fibrin, a so-called second generation PRP, and its slow-releasing biology and effects on fat grafts compared to PRP in both animal and clinical research. Finally, we provide a general foundation on which to critically evaluate earlier studies, discuss the limitations of previous research, and direct plans for future experiments to improve the optimal effects of PRP in fat grafting.

  11. Hepatitis Vaccines

    OpenAIRE

    Ogholikhan, Sina; Schwarz, Kathleen B.

    2016-01-01

    Viral hepatitis is a serious health problem all over the world. However, the reduction of the morbidity and mortality due to vaccinations against hepatitis A and hepatitis B has been a major component in the overall reduction in vaccine preventable diseases. We will discuss the epidemiology, vaccine development, and post-vaccination effects of the hepatitis A and B virus. In addition, we discuss attempts to provide hepatitis D vaccine for the 350 million individuals infected with hepatitis B ...

  12. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  13. The Feasibility of Hepatic Resections Using a Bipolar Radiofrequency Device (Habib®).

    Science.gov (United States)

    Civil, Osman; Kement, Metin; Okkabaz, Nuri; Haksal, Mustafa; Gezen, Cem; Oncel, Mustafa

    2015-08-01

    The bipolar radiofrequency device (Habib®) has been recently introduced in order to reduce intraoperative bleeding for a safe hepatic resection as an alternative to the conventional tools. However, indications, perioperative findings, and outcome of the device for hepatic resections remain and deserve to be analyzed. The current study aims to analyze the feasibility of the bipolar radiofrequency device (Habib®) for hepatic resections. Information of the patients that underwent hepatic resection using with the Habib® device between 2007 and 2011 was abstracted. Patient, disease, and operation-related findings and perioperative data were investigated. A total of 71 cases (38 [53.5 %] males, mean age was 56.8 ± 11.9) were analyzed. Metastatic disease (n = 55; 77.5 %) was the leading indication followed by primary liver and biliary malignancies (n = 7; 9.9 %), hemangioma (n = 5; 7 %), hydatid disease (n = 3; 2.8 %), and hepatic gunshot trauma (n = 1; 1.4 %). Metastasectomy was the most commonly performed procedure (n = 31; 56.3 %), but in 24 (77.4 %) cases, it was performed in addition to extended resections. Other procedures in the study patients include segmentectomy in 17, bisegmentectomy in 19, trisegmentectomy in 17, right or left hepatectomy in 8, and extended right/left hepatectomy in 3. The mean (±SD) operation time was 241.7 ± 78.2 min. The median amount of bleeding was 300 cc (range 25-2500), and 23 (32.4 %) cases required perioperative transfusion. The median hospitalization period was 5 days (range 1-47). Lengthened drainage (n = 9, 12.7 %) and intraabdominal abscess (n = 8, 11.23 %) were the most common problems. Hepatic resections using the Habib® device seem to be feasible in cases with primary and metastatic hepatic lesions and benign liver masses and even those with hepatic trauma. It may lessen the amount of intraoperative hemorrhage, although lengthened drainage and intraabdominal abscess

  14. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  15. Hepatitis Vaccines

    Directory of Open Access Journals (Sweden)

    Sina Ogholikhan

    2016-03-01

    Full Text Available Viral hepatitis is a serious health problem all over the world. However, the reduction of the morbidity and mortality due to vaccinations against hepatitis A and hepatitis B has been a major component in the overall reduction in vaccine preventable diseases. We will discuss the epidemiology, vaccine development, and post-vaccination effects of the hepatitis A and B virus. In addition, we discuss attempts to provide hepatitis D vaccine for the 350 million individuals infected with hepatitis B globally. Given the lack of a hepatitis C vaccine, the many challenges facing the production of a hepatitis C vaccine will be shown, along with current and former vaccination trials. As there is no current FDA-approved hepatitis E vaccine, we will present vaccination data that is available in the rest of the world. Finally, we will discuss the existing challenges and questions facing future endeavors for each of the hepatitis viruses, with efforts continuing to focus on dramatically reducing the morbidity and mortality associated with these serious infections of the liver.

  16. Hepatitis Vaccines

    Science.gov (United States)

    Ogholikhan, Sina; Schwarz, Kathleen B.

    2016-01-01

    Viral hepatitis is a serious health problem all over the world. However, the reduction of the morbidity and mortality due to vaccinations against hepatitis A and hepatitis B has been a major component in the overall reduction in vaccine preventable diseases. We will discuss the epidemiology, vaccine development, and post-vaccination effects of the hepatitis A and B virus. In addition, we discuss attempts to provide hepatitis D vaccine for the 350 million individuals infected with hepatitis B globally. Given the lack of a hepatitis C vaccine, the many challenges facing the production of a hepatitis C vaccine will be shown, along with current and former vaccination trials. As there is no current FDA-approved hepatitis E vaccine, we will present vaccination data that is available in the rest of the world. Finally, we will discuss the existing challenges and questions facing future endeavors for each of the hepatitis viruses, with efforts continuing to focus on dramatically reducing the morbidity and mortality associated with these serious infections of the liver. PMID:26978406

  17. Primary hepatic artery embolization in pediatric blunt hepatic trauma.

    Science.gov (United States)

    Ong, Caroline C P; Toh, Luke; Lo, Richard H G; Yap, Te-Lu; Narasimhan, Kannan

    2012-12-01

    Non-operative management of isolated blunt hepatic trauma is recommended except when hemodynamic instability requires immediate laparotomy. Hepatic artery angioembolization is increasingly used for hepatic injuries with ongoing bleeding as demonstrated by contrast extravasation on the CT scan. It is used primarily or after laparotomy to control ongoing hemorrhage. Hepatic angioembolization as part of multimodality management of hepatic trauma is reported mainly in adults, with few pediatric case reports. We describe our institution experience with primary pediatric hepatic angioembolization and review the literature with regard to indications and complications. Two cases (3 and 8 years old), with high-grade blunt hepatic injuries with contrast extravasation on the CT scan were successfully managed by emergency primary hepatic angioembolization with minimal morbidity and avoided laparotomy. To date, the only reports of pediatric hepatic angioembolization for trauma are 5 cases for acute bleeding and 15 delayed cases for pseudoaneurysm. The role of hepatic angioembolization in the presence of an arterial blush on CT in adults is accepted, but contested in a pediatric series, despite higher transfusion rate and mortality rate. We propose that hepatic angioembolization should be considered adjunct treatment, in lieu of, or in addition to emergency laparotomy for hemostasis in pediatric blunt hepatic injury. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Feature Hepatitis: Hepatitis Symptoms, Diagnosis, Treatment & Prevention

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Feature Hepatitis Hepatitis: Symptoms, Diagnosis, Treatment & Prevention Past Issues / Spring 2009 ... No appetite Fever Headaches Diagnosis To check for hepatitis viruses, your doctor will test your blood. You ...

  19. Multiple arterial grafts in coronary artery bypass grafting, Sohag University Hospital's initial experience

    Directory of Open Access Journals (Sweden)

    A.A.A. Elsayed

    2017-12-01

    Conclusions: Using multiple arterial grafts did not add a significant risk or time to the classic CABG. With accumulating evidence about better patency rate in arterial grafts, MAR is recommended especially in younger patients undergoing CABG.

  20. PREVALENCE OF ''TTV'' IN PATIENTS WITH CHRONIC VIRAL HEPATITIS ''B'' AND ''C''

    International Nuclear Information System (INIS)

    NOSSEIR, N.M.; MANSOUR, H.H.; FAHMY, N.M.

    2007-01-01

    Transfusion transmitted virus (TTV) is an enveloped single strand virus discovered in serum of patients with post-transfusion hepatitis of unknown etiology in Japan and designated as TT virus (TTV). To investigate the frequency of TTV infection in patients with viral hepatitis B or C, 25 Egyptian patients with hepatitis C virus (HCV) aged 8-40 years and 25 patients with B virus (HBV) aged 8-57 years were tested. Detection of TTV-DNA was performed by semi-nested polymerase chain reaction (PCR) using TTV-specific primers. Serum levels of transaminases were tested. The prevalence of TTV in patients with chronic viral hepatitis B or C was frequent and the co-infection of TTV with HCV or HBV was accompanied by a high level of transaminases as compared to that of HBV or HCV alone. The present study confirms and extends that infection alone doesn't cause significant liver damage

  1. Radiation-induced grafting from binary mixture of monomers onto cellulose acetate film and the characterization of the graft copolymer

    International Nuclear Information System (INIS)

    Bhattacharyya, S.N.; Maldas, D.

    1984-01-01

    Binary mixtures of styrene and acrylamide in methanol-water were grafted onto cellulose acetate films by taking recourse to preirradiation grafting technique. The extent of total grafting was determined from the measured weight increase. The percent acrylamide residue in the graft copolymer was calculated from the observed nitrogen content but the polystyrene residue in the grafted sample was determined by IR spectral studies. When the specific permeability of water vapour through the grafted films is measured, it is observed that the specific permeability increases with the increase of grafting of acrylamide in all humidities, but in case of styrene which is a nonpolar molecule the permeability is found to show a reversed order. In the case of mixed graft the permeability pattern pertains to that when both styrene and acrylamide have their effective roles to play. (author)

  2. Viral Hepatitis

    Science.gov (United States)

    ... Home A-Z Health Topics Viral hepatitis Viral hepatitis > A-Z Health Topics Viral hepatitis (PDF, 90 ... liver. Source: National Cancer Institute Learn more about hepatitis Watch a video. Learn who is at risk ...

  3. Comparison of mesencephalic free-floating tissue culture grafts and cell suspension grafts in the 6-hydroxydopamine-lesioned rat

    DEFF Research Database (Denmark)

    Meyer, Morten; Widmer, H R; Wagner, B

    1998-01-01

    of grafted dopaminergic neurons and to correlate that with the behavioral effects. Additional cultures and acutely prepared explants were also fixed and stored for histological investigation in order to estimate the loss of dopaminergic neurons in culture and after transplantation. Similar behavioral...... numbers of TH-immunoreactive (TH-ir) neurons in grafts of cultured tissue (775 +/- 98, mean +/- SEM) and grafts of fresh, dissociated cell suspension (806 +/- 105, mean +/- SEM). Cell counts in fresh explants, 7-day-old cultures, and grafted cultures revealed a 68.2% loss of TH-ir cells 7 days after......Ventral mesencephalon (VM) of fetal rat and human origin grown as free-floating roller-tube (FFRT) cultures can survive subsequent grafting to the adult rat striatum. To further explore the functional efficacy of such grafts, embryonic day 13 ventral mesencephalic tissue was grafted either after 7...

  4. Iodine-131-labelled CDR grafted monoclonal antibody huA33 metastatic colorectal carcinoma: A case study

    International Nuclear Information System (INIS)

    Thomas, D.L.; Lee, F.T.; Scott, A.M.

    1997-01-01

    Full text: A 58-year-old woman was diagnosed with metastatic colorectal carcinoma two years after initial surgery for sigmoid carcinoma. As part of the staging work-up she was initially referred for a 18 F-FDG PET scan at the PET Centre. FDG PET scans of the abdomen and pelvis demonstrated multiple hepatic lesions, but there was no evidence of disease outside the liver. On the basis of extensive hepatic disease, the patient was scheduled for a laparotomy for insertion of an hepatic artery catheter for chemotherapy. In view of her clinical presentation, the patient was eligible for a Phase 1 trial with 131 l-labelled huA33, and agreed to participate. HuA33 is a humanised CDR-grafted recombinant monoclonal antibody directed against an antigen found on >95 per cent of all colorectal carcinomas, and on small bowel and colonic mucosa. The phase 1 trial is a protein dose escalation study designed to examine the biodistribution, pharmacokinetics, dosimetry and safety profile of huA33, and sequential gamma camera images of the whole body were obtained daily until seven days post infusion. SPECT images were obtained on day 6. Excellent localisation of 131 l-huA33 was seen in hepatic lesions. Calculation of whole body retention and tumour uptake was performed, and pharmacokinetic analysis also undertaken. Biopsies of tumour obtained at surgery were used to quantitate tumour uptake and cellular trafficking of 131 l-huA33. On the basis of this phase 1 study, future therapeutic trials of 131 I-huA33 are planned

  5. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  6. Preparation of poly(vinylbenzyl chloride)-grafted PFA film by a simultaneous irradiation grafting method

    International Nuclear Information System (INIS)

    Fei, Geng; Shin, Jun Hwa; Nho, Young Chang; Lee, Youn Sik

    2009-01-01

    In this study, PFA-g-PVBC films were prepared by a radiation grafting of vinylbenzyl chloride (VBC) monomer onto poly(tetrafluoroethylene-co-perfluoro propyl vinyl ether) (PFA) films by simultaneous irradiation method. IR, TGA, and SEM-EDX instruments were utilized to confirm the successful preparation of the grafted film. The effects of several irradiation conditions, including the dose, VBC concentration, and film thickness on the degree of grafting of PFA-g-PVBC film were investigated

  7. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  8. Rib Bone Graft Adjusted to Fit the Facial Asymmetry: A Frame Structure Graft.

    Science.gov (United States)

    Lee, Yoon Ho; Choi, Jong Hwan; Hwang, Kun; Choi, Jun Ho

    2015-10-01

    The authors introduce the concept of a "frame structure graft" in which a harvested rib bone was adjusted to fit facial asymmetry. On the costochondral junction of the sixth or seventh rib, a 5 cm incision was made. Through a subperiosteal dissection, the rib bone was harvested. Using a reciprocating saw, the harvested rib was scored on its anterior surface as well as its posterior surface with a partial depth at different intervals. The harvested rib bone was placed on the skin surface of the unaffected side of the face and a curvature was created exactly matching that of the unaffected side by bending the bone using a greenstick fracture. Thereafter, the graft was adjusted to conceal the asymmetry of the deficient side. The adjusted "frame structure" was transferred to the defect through the incisions on the affected side, and the "frame structure" graft was placed on the mandible or zygoma. The graft fixation was done externally with at least 2 Kirschner wires (K-wires). From January 2005 to August 2013, a total of 30 patients (13 men, 17 women, mean age 25.6 years) received a frame structure graft. All 30 patients achieved good healing at the operation site without complications. Donor-site morbidity as pneumothorax from the rib bone harvest was not found. Merits of this frame structure graft, the authors think, are that this method could allow a similar curvature to the normal side. In addition, the procedure itself is easy.

  9. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    International Nuclear Information System (INIS)

    El-Salmawi, K.M.; El-Naggar, A.M.; Said, H.M.; Zahran, A.H.

    1996-01-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr's salt), solvent composition (MeOH and H 2 O), radiation dose and dose rate were considered. It was found that the role of Mohr's salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr's salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H 2 O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs

  10. Hepatitis B

    Science.gov (United States)

    ... B Entire Lesson Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For Veterans and the Public Veterans ... in their blood (sometimes referred to as the hepatitis B viral load) and an unusually high level of a ...

  11. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy (ICP) Jaundice In Newborns Diseases of the Liver ... A Hepatitis B Hepatitis C Intrahepatic Cholestasis of Pregnancy (ICP) Jaundice In Newborns Diseases of the Liver ...

  12. Alcohol and Hepatitis

    Science.gov (United States)

    ... Home » Living with Hepatitis » Daily Living: Alcohol Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... heavy drinking, most heavy drinkers have developed cirrhosis. Hepatitis C and cirrhosis In general, someone with hepatitis ...

  13. Hepatitis C: Treatment

    Science.gov (United States)

    ... Public Home » Hepatitis C » Hepatitis C Treatment Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... Enter ZIP code here Enter ZIP code here Hepatitis C Treatment for Veterans and the Public Treatment ...

  14. Imaging features of anterior cruciate ligament reconstruction graft insufficiency

    International Nuclear Information System (INIS)

    Shang Yao; Zhang Yue; Tian Chunyan; Zheng Zhuozhao

    2011-01-01

    Objective: To investigate the imaging features of anterior cruciate ligament (ACL) graft insufficiency. Methods: X-Ray and MR imaging examinations in 24 consecutive patients who had ACL reconstructive graft insufficiency were retrospectively evaluated for tunnel position, osteoarthrosis and its related complications. Follow-up arthroscopy showed 16 graft tears and 8 graft laxities. Fisher exact test was used to compare tunnel malpositions, the proportion of graft tear on MRI and osteoarthrosis between graft tear group and graft laxity group. Results: Two malpositions of tibial tunnel and 3 malpositions of femoral tunnel were seen in graft tear group. Three-malpositions of tibial tunnel and 4 malpositions of femoral tunnel were seen in graft laxity group. The proportion of tibial or femoral malposition showed no significant difference between the two groups (P=0.289, P=0.167). In graft tear group, 15 complete graft tears were diagnosed correctly, 1 partial tear was misdiagnosed as normal on MRI. In graft laxity group, 4 grafts were diagnosed as normal and 4 were considered as graft tear on MRI. A significant difference was seen between the two groups (P=0.028) in the proportion of graft tear diagnosed on MRI. Fourteen osteoarthrosis were seen in graft tear group and 5 in graft laxity group. No significant difference was seen between the two groups (P= 0.289) in the proportion of osteoarthrosis. Conclusion: The proportions of tunnel malposition and osteoarthrosis showed no significant difference between the graft tear group and graft Laxity group. Most graft tears can be diagnosed accurately on MRI, but some cases of graft laxity may be misdiagnosed for graft tear. (authors)

  15. Improved human endometrial stem cells differentiation into functional hepatocyte-like cells on a glycosaminoglycan/collagen-grafted polyethersulfone nanofibrous scaffold.

    Science.gov (United States)

    Khademi, Farzaneh; Ai, Jafar; Soleimani, Masoud; Verdi, Javad; Mohammad Tavangar, Seyed; Sadroddiny, Esmaeil; Massumi, Mohammad; Mahmoud Hashemi, Seyed

    2017-11-01

    Liver tissue engineering (TE) is rapidly emerging as an effective technique which combines engineering and biological processes to compensate for the shortage of damaged or destroyed liver tissues. We examined the viability, differentiation, and integration of hepatocyte-like cells on an electrospun polyethersulfone (PES) scaffold, derived from human endometrial stem cells (hEnSCs). Natural polymers were separately grafted on plasma-treated PES nanofibers, that is, collagen, heparan sulfate (HS) and collagen-HS. Galactosilated PES (PES-Gal) nanofibrous were created. The engineering and cell growth parameters were considered and compared with each sample. The cellular studies revealed increased cell survival, attachment, and normal morphology on the bioactive natural polymer-grafted scaffolds after 30 days of hepatic differentiation. The chemical and molecular assays displayed hepatocyte differentiation. These cells were also functional, showing glycogen storage, α-fetoprotein, and albumin secretion. The HS nanoparticle-grafted PES nanofibers demonstrated a high rate of cell proliferation, differentiation, and integration. Based on the observations mentioned above, engineered tissue is a good option in the future, for the commercial production of three-dimensional liver tissues for clinical purposes. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2516-2529, 2017. © 2016 Wiley Periodicals, Inc.

  16. Inheritance of graft compatibility in Douglas fir.

    Science.gov (United States)

    D.L. Copes

    1973-01-01

    Graft compatibility of genetically related and unrelated rootstock-scion combinations was compared. Scion clones were 75% compatible when grafted on half-related rootstocks but only 56% compatible when grafted on unrelated rootstocks. Most variance associated with graft incompatibility in Douglas-fir appears to be caused by multiple genes.

  17. Occult hepatitis B among Iranian hepatitis C patients

    Directory of Open Access Journals (Sweden)

    Ahmad shavakhi

    2009-02-01

    Full Text Available

    • BACKGROUND: Occult hepatitis B is defined as presence of HBV DNA in tissue or serum without hepatitis B surface antigen. The aim of this study is to determine frequency of occult hepatitis B among hepatitis C patients in Tehran and compare the route of transmission and liver enzymes between positive and negative HBV DNA patients.
    • METHODS: In a cross sectional study, serum of 103 hepatitis C cases (79.6% men and 20.4% women were analyzed for s, x and core genes via a nested polymerase chain reaction technique.
    • RESULTS: HBV DNA was detectable in serum of 20 patients (19.4%. No significant difference in age, sex and route of transmission were seen in HBV DNA positive and negative patients. In HBV DNA positive and negative groups, mean of AST was 73, 47 (p < 0.05 and mean of ALT was 76 and 36 respectively (p < 0.05.
    • CONCLUSION: Occult hepatitis B was observed in a considerable number of hepatitis C patients in Tehran. It was associated with elevation in liver enzyme but was not related to route of transmission.
    • KEY WORD: Occult hepatitis B, hepatitis C, cirrhosis.

  18. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  19. Radiation-induced grafting of acrylamide onto guar gum in aqueous medium: Synthesis and characterization of grafted polymer guar-g-acrylamide

    Energy Technology Data Exchange (ETDEWEB)

    Biswal, Jayashree [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Kumar, Virendra [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Bhardwaj, Y.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)]. E-mail: ykbhard@magnum.barc.ernet.in; Goel, N.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Dubey, K.A. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Chaudhari, C.V. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Sabharwal, S. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2007-10-15

    Mutual radiation grafting technique has been applied to carry out grafting of acrylamide (AAm) onto guar gum (GG) using high-energy Co{sup 60} {gamma} radiation to enhance its flocculating properties for industrial effluents. The grafted product was characterized using analytical probes like elemental analysis, thermal analysis, Fourier transformed infrared (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). The grafting extent was observed to decrease with the dose rate and increase with the concentration of AAm. Thermo gravimetric analysis (TGA) of grafted and ungrafted samples indicated better stability of grafted product. {gamma} and microwave radiation effect on grafted and virgin GG has also been reported.

  20. Hepatic artery infusion (HAI) for hepatic metastases in combination with hepatic resection and hepatic radiation

    International Nuclear Information System (INIS)

    Merrick, H.W.; Dobelbower, R.R.; Ringleint, J.F.; Skeel, R.T.

    1986-01-01

    Renewed interest in hepatic artery infusion has been stimulated by the development of a totally implantable pump which eliminates many of the problems encountered by the external pumps and catheters. As the potential benefit of hepatic artery infusion would be greater if either all gross disease were removed by prior resection, or alternatively, if non-resectable disease were irradiated in conjunction with hepatic artery infusion, the authors initiated a phase I-II trial to evaluate combined modality therapy

  1. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  2. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  3. Islet grafting and imaging in a bioengineered intramuscular space.

    Science.gov (United States)

    Witkowski, Piotr; Sondermeijer, Hugo; Hardy, Mark A; Woodland, David C; Lee, Keagan; Bhagat, Govind; Witkowski, Kajetan; See, Fiona; Rana, Abbas; Maffei, Antonella; Itescu, Silviu; Harris, Paul E

    2009-11-15

    Because the hepatic portal system may not be the optimal site for islet transplantation, several extrahepatic sites have been studied. Here, we examine an intramuscular transplantation site, bioengineered to better support islet neovascularization, engraftment, and survival, and we demonstrate that at this novel site, grafted beta cell mass may be quantitated in a real-time noninvasive manner by positron emission tomography (PET) imaging. Streptozotocin-induced rats were pretreated intramuscularly with a biocompatible angiogenic scaffold received syngeneic islet transplants 2 weeks later. The recipients were monitored serially by blood glucose and glucose tolerance measurements and by PET imaging of the transplant site with [11C] dihydrotetrabenazine. Parallel histopathologic evaluation of the grafts was performed using insulin staining and evaluation of microvasularity. Reversal of hyperglycemia by islet transplantation was most successful in recipients pretreated with bioscaffolds containing angiogenic factors when compared with those who received no bioscaffolds or bioscaffolds not treated with angiogenic factors. PET imaging with [11C] dihydrotetrabenazine, insulin staining, and microvascular density patterns were consistent with islet survival, increased levels of angiogenesis, and with reversal of hyperglycemia. Induction of increased neovascularization at an intramuscular site significantly improves islet transplant engraftment and survival compared with controls. The use of a nonhepatic transplant site may avoid intrahepatic complications and permit the use of PET imaging to measure and follow transplanted beta cell mass in real time. These findings have important implications for effective islet implantation outside of the liver and offer promising possibilities for improving islet survival, monitoring, and even prevention of islet loss.

  4. Pure 3D laparoscopic living donor right hemihepatectomy in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

    Science.gov (United States)

    Hong, Suk Kyun; Suh, Kyung-Suk; Kim, Hyo-Sin; Yoon, Kyung Chul; Ahn, Sung-Woo; Oh, Dongkyu; Kim, Hyeyoung; Yi, Nam-Joon; Lee, Kwang-Woong

    2017-11-01

    Despite increases in the performance of pure laparoscopic living donor hepatectomy, variations in the bile duct or portal vein have been regarded as relative contraindications to this technique [1-3]. This report describes a donor with separate right posterior and right anterior hepatic ducts and portal veins who underwent pure laparoscopic living donor right hemihepatectomy, integrated with 3D laparoscopy and indocyanine green (ICG) near-infrared fluorescence cholangiography [1, 4, 5]. A 50-year-old man offered to donate part of his liver to his older brother, who required a transplant for hepatitis B-associated liver cirrhosis and hepatocellular carcinoma. Donor height was 178.0 cm, body weight was 82.7 kg, and body mass index was 26.1 kg/m 2 . Preoperative computed tomography and magnetic resonance cholangiopancreatography showed that the donor had separate right posterior and right anterior hepatic ducts and portal veins. The entire procedure was performed under 3D laparoscopic view. Following intravenous injections of 0.05 mg/kg ICG, ICG near-infrared fluorescence camera was used to demarcate the exact transection line and determine the optimal bile duct division point. The total operation time was 443 min; the donor required no transfusions and experienced no intraoperative complications. The graft weighed 1146 g with a graft-to-recipient weight ratio of 1.88%. The optimal bile duct division point was identified using ICG fluorescence cholangiography, and the bile duct was divided with good patency without any stricture. The right anterior and posterior portal veins were transected with endostaplers without any torsion. The patient was discharged on postoperative day 8, with no complications. Using a 3D view and ICG fluorescence cholangiography, pure 3D laparoscopic living donor right hemihepatectomy is feasible in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

  5. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Salmawi, K M; El-Naggar, A M; Said, H M; Zahran, A H [Radiation Chemistry Department, National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr`s salt), solvent composition (MeOH and H{sub 2} O), radiation dose and dose rate were considered. It was found that the role of Mohr`s salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr`s salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H{sub 2} O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs.

  6. Early postoperative erythromycin breath test correlates with hepatic cytochrome P4503A activity in liver transplant recipients

    DEFF Research Database (Denmark)

    Schmidt, L E; Olsen, A K; Stentoft, K

    2001-01-01

    BACKGROUND: Interindividual variation in the pharmacokinetics of the immunosuppressive agents cyclosporine (INN, ciclosporin) and tacrolimus may result from differences in the activity of cytochrome P4503A (CYP3A). The erythromycin breath test is an in vivo assay of hepatic CYP3A activity......, but the method has never been directly validated. The aim of the study was to investigate whether an early postoperative erythromycin breath test correlated with the hepatic CYP3A protein level and catalytic activity in liver transplant recipients. METHODS: In 18 liver transplant recipients, the erythromycin...... breath test was performed within 2 hours after transplantation. A graft biopsy was obtained during surgery and analyzed for the CYP3A protein level by Western blotting and for CYP3A activity with erythromycin demethylation and testosterone 6beta- hydroxylation assays. RESULTS: The erythromycin breath...

  7. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  8. 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation

    International Nuclear Information System (INIS)

    Frericks, Bernd B.; Caldarone, Franco C.; Savellano, Dagmar Hoegemann; Stamm, Georg; Kirchhoff, Timm D.; Shin, Hoen-Oh; Galanski, Michael; Nashan, Bjoern; Klempnauer, Juergen; Schenk, Andrea; Selle, Dirk; Spindler, Wolf; Peitgen, Heinz-Otto

    2004-01-01

    The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110±180 ml for right lobes, 820 ml for the left lobe and 270±30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments. (orig.)

  9. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  10. Tuning the Mechanical Properties of Polymer Nanocomposites Filled with Grafted Nanoparticles by Varying the Grafted Chain Length and Flexibility

    Directory of Open Access Journals (Sweden)

    Zixuan Wang

    2016-08-01

    Full Text Available By employing coarse-grained molecular dynamics simulation, we simulate the spatial organization of the polymer-grafted nanoparticles (NPs in homopolymer matrix and the resulting mechanical performance, by particularly regulating the grafted chain length and flexibility. The morphologies ranging from the agglomerate, cylinder, sheet, and string to full dispersion are observed, by gradually increasing the grafted chain length. The radial distribution function and the total interaction energy between NPs are calculated. Meanwhile, the stress–strain behavior of each morphology and the morphological evolution during the uniaxial tension are simulated. In particular, the sheet structure exhibits the best mechanical reinforcement compared to other morphologies. In addition, the change of the grafted chain flexibility to semi-flexibility leads to the variation of the morphology. We also find that at long grafted chain length, the stress–strain behavior of the system with the semi-flexible grafted chain begins to exceed that of the system with the flexible grafted chain, attributed to the physical inter-locking interaction between the matrix and grafted polymer chains. A similar transition trend is as well found in the presence of the interfacial chemical couplings between grafted and matrix polymer chains. In general, this work is expected to help to design and fabricate high performance polymer nanocomposites filled with grafted NPs with excellent and controllable mechanical properties.

  11. A comparison of patency and interventions in thigh versus Hemodialysis Reliable Outflow grafts for chronic hemodialysis vascular access.

    Science.gov (United States)

    Brownie, Evan R; Kensinger, Clark D; Feurer, Irene D; Moore, Derek E; Shaffer, David

    2016-11-01

    months, 1 year, and 3 years were 88%, 88%, and 70% for the thigh grafts and 53%, 43%, and 12% for the HeRO grafts. There were no differences in ischemic (P = .63) or infectious (P = .79) complications between the groups. Multivariable logistic regression demonstrated that after adjusting for follow-up time, HeRO grafts were associated with an increased number of interventions (P = .03). Thigh grafts have significantly better primary, assisted primary, and secondary patency compared with HeRO grafts. There is no significant difference between thigh grafts and HeRO grafts in ischemic or infectious complications. Our logistic regression model demonstrated an association between HeRO grafts and an increased number of interventions to maintain or restore patency. Although HeRO grafts may extend the use of the upper extremity, thigh grafts provide a more durable option for chronic hemodialysis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. HIV, hepatitis B, and hepatitis C in Zambia

    Directory of Open Access Journals (Sweden)

    Kenneth C Kapembwa

    2011-01-01

    Full Text Available Objectives : Epidemiologic data of HIV and viral hepatitis coinfection are needed in sub-Saharan Africa to guide health policy for hepatitis screening and optimized antiretroviral therapy (ART. Materials and Methods: We screened 323 HIV-infected, ART-eligible adults for hepatitis B surface antigen (HBsAg and hepatitis C antibody (HCV Ab at a tertiary hospital in Lusaka, Zambia. We collected basic demographic, medical, and laboratory data to determine predictors for coinfection. Results: Of 323 enrolled patients, 32 (9.9%; 95% CI=6.7-13.2% were HBsAg positive, while 4 (1.2%; 95% CI=0.03-2.4% were HCV Ab positive. Patients with hepatitis B coinfection were more likely to be 200 IU/L was uncommon and did not differ between the two groups (3.4% vs. 2.3%; P=0.5. We were unable to determine predictors of hepatitis C infection due to the low prevalence of disease. Conclusions: HIV and hepatitis B coinfection was common among patients initiating ART at this tertiary care facility. Routine screening for hepatitis B should be considered for HIV-infected persons in southern Africa.

  13. Hepatitis (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Hepatitis KidsHealth / For Parents / Hepatitis Print en español Hepatitis What Is Hepatitis? Hepatitis is an inflammation of the liver. The ...

  14. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  15. Physical properties of agave cellulose graft polymethyl methacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan [Polymer Research Centre (PORCE), School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi Selangor (Malaysia)

    2013-11-27

    The grafting polymerization of methyl methacrylate and Agave cellulose was prepared and their structural analysis and morphology were investigated. The grafting reaction was carried out in an aqueous medium using ceric ammonium nitrate as an initiator. The structural analysis of the graft copolymers was carried out by Fourier transform infrared and X-ray diffraction. The graft copolymers were also characterized by field emission scanning electron microscopy (FESEM). An additional peak at 1732 cm{sup −1} which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted Agave cellulose, respectively. Another evidence of grafting showed in the FESEM observation, where the surface of the grafted cellulose was found to be roughed than the raw one.

  16. PRFM enhance wound healing process in skin graft.

    Science.gov (United States)

    Reksodiputro, Mirta; Widodo, Dini; Bashiruddin, Jenny; Siregar, Nurjati; Malik, Safarina

    2014-12-01

    Facial plastic and reconstructive surgery often used skin graft on defects that cannot be covered primarily by a local flap. However, wound healing using skin graft is slow, most of the time the graft is contractured and the take of graft is not optimal. Platelet rich fibrin matrix (PRFM) is a new generation of concentrated platelets that produce natural fibrin and reported to speed up the healing process. Application of PRFM in the skin graft implants is expected to increase the survival of the graft. We used porcine as animal models to elucidate the effect of autologous PRFM on wound healing in full-thickness (FTSG) and split-thickness (STSG) skin grafts. Survival level of the skin graft was determined by using ImageJ software based on the formation of collagen type 1 and graft take. We observed that the use of PRFM in FTSG and STSG increased type 1 collagen formation. We also found that PRFM addition in STSG gave the best skin graft take. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Improvement of polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    1999-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect ultimate performance of polymer product. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method, photoprotector 2-hydroxy-4-(3-methacryloxy-2- hydroxy-propoxy) benzophenone (HMB) has been readily grafted to low density polyethylene (LDPE) in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. The grafted LDPE film in methanol and tetrahydrofuran (containing 1 w/w % of grafted HMB), 1 w/w % blended HMB with LDPE and nongrafted LDPE film, were all exposed to accelerated aging and natural weathering and their spectral changes, expressed by the carbonyl index, were then compared. The change of elongation at break and tensile strength were measured in the course of aging. UV stability tests on aged films and change in mechanical properties indicate a pronounced protective effect achieved by grafted stabilizer. Grafting in methanol solution appears to be an efficient photostabilization treatment and the most economical with respect to the consumption of monomer, the grafting yield being less than 0.5%. Surface grafting is an efficient photostabilization method since grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated. (author)

  18. Modification of polyetherurethane for biomedical application by radiation induced grafting. II. Water sorption, surface properties, and protein adsorption of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1984-01-01

    A series of polyetherurethane films grafted by means of gamma radiation with hydrophilic or reactive monomers (2-hydroxyethyl methacrylate, 2,3-epoxypropyl methacrylate, 2,3-dihydroxypropyl methacrylate, and acrylamide) and partially chemically modified were subjected to various physico-chemical investigation methods involving water sorption, contact angle, and protein adsorption measurements. From contact angle data the interfacial free energy gamma sw between grafted films and water was calculated. It was found that the water uptake of grafted films increases with grafting yield or, in the case of grafted and afterwards chemically modified films, with reaction yield; the diffusion coefficient of water in the modified films also increases with grafting yield. Contact angle studies revealed all grafted films to have surfaces more hydrophilic than the ungrafted trunk polymer. The degree of hydrophilicity--especially of HEMA-grafted films--strongly depends on grafting conditions. For some grafted samples with high surface hydrophilicity very low interfacial free energies approaching zero were measured. The study of the competitive adsorption of bovine serum albumin, gamma-globulin, and fibrinogen from a synthetic protein solution onto modified films showed that the adsorption of albumin increases markedly with increasing grafting yields, whereas the fibrinogen and gamma-globulin adsorption only slightly increases. A correlation between interfacial free energy and protein adsorption in the sense of the minimum interfacial free energy hypothesis was found only for samples with grafting yields below 5%. At higher grafting yields the increased surface area complicates the analysis

  19. Homogeneous cation exchange membrane by radiation grafting

    International Nuclear Information System (INIS)

    Kolhe, Shailesh M.; G, Agathian; Ashok Kumar

    2001-01-01

    Preparation of a strong cation exchange membrane by radiation grafting of styrene on to polyethylene (LDPE) film by mutual irradiation technique in the presence of air followed by sulfonation is described. The grafting has been carried out in the presence of air and without any additive. Low dose rate has been seen to facilitate the grafting. Further higher the grafting percentage more is the exchange capacity. The addition of a swelling agent during the sulfonation helped in achieving the high exchange capacity. The TGA-MASS analysis confirmed the grafting and the sulfonation. (author)

  20. Nuclear accidents and bone marrow graft

    International Nuclear Information System (INIS)

    Bernard, J.

    1988-01-01

    In case of serious contamination, the only efficacious treatment is the bone marrow grafts. The graft types and conditions have been explained. To restrict the nuclear accidents consequences, it is recommended to: - take osseous medulla of the personnel exposed to radiations and preserve it , that permits to carry out rapidly the auto-graft in case of accidents; - determine, beforehand, the HLA group of the personnel; - to register the voluntary donors names and addresses, and their HLA group, that permits to find easily a compatible donar in case of allo-graft. (author)

  1. Enhancement of the grafting performance and of the water absorption of cassava starch graft copolymer by gamma radiation

    International Nuclear Information System (INIS)

    Kiatkamjornwong, Suda; Meechai, Nispa

    1997-01-01

    Enhancement of the gamma radiation grafting of acrylonitrile onto gelatinized cassava starch was investigated. Infrared spectrometry was used to follow the chemical changes in the grafting reaction and from saponification. The saponified starch-g-PAN (HSPAN) was then characterized in terms of grafting parameters to provide a guide for the optimum total dose (kGy) and the appropriate ratio of starch/acrylonitrile for a fixed dose rate of 2.5 x 10 -1 kGy/min. Other dose rates were also carried out to obtain the appropriate result of grafting copolymerization and of water absorption. A thin aluminium foil, covering the inner wall of the reaction vessel, was found to be far more effective than any other metal films in the enhancement of the grafting reaction and the water absorption as well. Nitric acid in the medium increases the grafting yield and the water absorption. Methyl ether hydroquinone inhibitor was evaluated for its ability to increase homopolymerization and decrease graft reaction. When styrene was used as a comonomer, it hampered the grafting of acrylonitrile onto starch backbone. The water absorption capacity was improved by freeze-drying the HSPAN. The treatment of the HSPAN with aluminium trichloride hexahydrate was found to enhance the degree of wicking, but to decrease the water absorbency. (author)

  2. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  3. Hydrogen, a potential safeguard for graft-versus-host disease and graft ischemia-reperfusion injury?

    Science.gov (United States)

    Yuan, Lijuan; Shen, Jianliang

    2016-01-01

    Post-transplant complications such as graft-versus-host disease and graft ischemia-reperfusion injury are crucial challenges in transplantation. Hydrogen can act as a potential antioxidant, playing a preventive role against post-transplant complications in animal models of multiple organ transplantation. Herein, the authors review the current literature regarding the effects of hydrogen on graft ischemia-reperfusion injury and graft-versus-host disease. Existing data on the effects of hydrogen on ischemia-reperfusion injury related to organ transplantation are specifically reviewed and coupled with further suggestions for future work. The reviewed studies showed that hydrogen (inhaled or dissolved in saline) improved the outcomes of organ transplantation by decreasing oxidative stress and inflammation at both the transplanted organ and the systemic levels. In conclusion, a substantial body of experimental evidence suggests that hydrogen can significantly alleviate transplantation-related ischemia-reperfusion injury and have a therapeutic effect on graft-versus-host disease, mainly via inhibition of inflammatory cytokine secretion and reduction of oxidative stress through several underlying mechanisms. Further animal experiments and preliminary human clinical trials will lay the foundation for hydrogen use as a drug in the clinic. PMID:27652837

  4. Hepatitis B (HBV)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Hepatitis B KidsHealth / For Teens / Hepatitis B What's in ... Prevented? Print en español Hepatitis B What Is Hepatitis B? Hepatitis B is an infection of the ...

  5. Hepatitis A Vaccine

    Science.gov (United States)

    Twinrix® (as a combination product containing Hepatitis A Vaccine, Hepatitis B Vaccine) ... Why get vaccinated against hepatitis A?Hepatitis A is a serious liver disease. It is caused by the hepatitis A virus (HAV). HAV is spread from ...

  6. Surgical Control of a Primary Hepatic Carcinoid Tumor: A Case Report

    Directory of Open Access Journals (Sweden)

    Norio Yokoigawa

    2009-04-01

    Full Text Available We report a primary hepatic carcinoid tumor occurring in a 47-year-old man. The patient consulted our hospital complaining of epigastralgia. Abdominal ultrasonography, computed tomography scanning, and magnetic resonance imaging showed a large mass in the right lobe of the liver. FDG-PET revealed 18F-FDG uptake by the right hepatic lobe. The tumor was a solid mass with cystic components, approximately 15 cm in diameter. We conducted an extended right lobectomy of the liver. The resected specimen was a solid tumor with cystic components and hemorrhagic lesion. Microscopic findings showed that the tumor cells had round nuclei and formed trabecular patterns. Immunohistologically, tumor cells were stained positive for chromogranin A, neuron specific enolase, CD56, and S-100. Careful examinations before and after the operation revealed no other possible origin of the tumor. Based on these findings, the tumor was diagnosed as a primary hepatic carcinoid. This is a report of a rare case of a primary hepatic carcinoid tumor with a discussion of several other relevant reports.

  7. Adaptive significance of root grafting in trees

    Energy Technology Data Exchange (ETDEWEB)

    Loehle, C.; Jones, R.

    1988-12-31

    Root grafting has long been observed in forest trees but the adaptive significance of this trait has not been fully explained. Various authors have proposed that root grafting between trees contributes to mechanical support by linking adjacent root systems. Keeley proposes that this trait would be of greatest advantage in swamps where soils provide poor mechanical support. He provides as evidence a greenhouse study of Nyssa sylvatica Marsh in which seedlings of swamp provenance formed between-individual root grafts more frequently than upland provenance seedlings. In agreement with this within-species study, Keeley observed that arid zone species rarely exhibit grafts. Keeley also demonstrated that vines graft less commonly than trees, and herbs never do. Since the need for mechanical support coincides with this trend, these data seem to support his model. In this paper, the authors explore the mechanisms and ecological significance of root grafting, leading to predictions of root grafting incidence. Some observations support and some contradict the mechanical support hypothesis.

  8. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  9. Radiation-induced grafting of styrene on to LDPE films for preparation of cation exchange membranes, i. effect of grafting conditions

    International Nuclear Information System (INIS)

    Mohamed Mahmoud Nasef; Hamdani Saidi; Hussin Mohd Nor; Khairul Zaman Mohd Dahlan; Kamaruddin Hashim

    1999-01-01

    PE-g-polystyrene copolymers were prepared by simultaneous radiation-induced graft copolymerization of styrene onto low density polyethylene (LDPE) films. The effects of irradiation conditions such as monomer concentration, Mohr's salt and sulfuric acid addition, irradiation dose and dose rate were investigated. It was found that the degree of grafting increases with the monomer concentration and reaches its maximum value at styrene concentration of 80 vol %. The addition of Mohr's salt as well as sulfuric acid caused a considerable increase in the degree of grafting with various styrene concentrations. The degree of grafting also increased with the increased in irradiation dose, however it remarkably decreased with the increase in dose rate. The formation of graft copolymers was confirmed by FTIR analysis. The structural investigation of the graft copolymer was carried out by x-ray diffraction (XRD). The degree of crystallinity content was found to be decreased with the increase in the degree of grafting and influenced the mechanical properties of the graft copolymer to some extent. (Author)

  10. Complications in skin grafts when continuing antithrombotic therapy prior to cutaneous surgery requiring skin grafting

    DEFF Research Database (Denmark)

    Jarjis, Reem Dina; Jørgensen, Lone; Finnerup, Kenneth

    2015-01-01

    Abstract The risk of postoperative bleeding and wound healing complications in skin grafts among anticoagulated patients undergoing cutaneous surgery has not been firmly established. The objective was to examine the literature and assess the risk of postoperative bleeding or wound healing...... complications in skin grafts among anticoagulated patients, compared with patients who discontinue or patients who are not receiving antithrombotic therapy prior to cutaneous surgery requiring skin grafting. A systematic review examining the effect of antithrombotic therapy on cutaneous surgery was performed...... studies were of prospective and retrospective design. Most of the reviewed studies suggest that the use of antithrombotic therapy can increase the risk of bleeding complications in skin grafts. These complications are only wound threatening and not life threatening. Therefore, this is of concern mostly...

  11. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. Hepatitis C: Managing Pain

    Science.gov (United States)

    ... Pain: Entire Lesson Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For Veterans and the Public Veterans and the Public Home Hepatitis A Hepatitis B Hepatitis C Hepatitis C Home Getting ...

  13. Corneal graft reversal: Histopathologic report of two cases.

    Science.gov (United States)

    Qahtani, Abdullah A; Alkatan, Hind M

    2014-10-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal.

  14. Characterization and Some Properties of Functionalized Graft Copolymer

    International Nuclear Information System (INIS)

    Hegazy El-Sayed, A.; Kamal, H.; Mahmoud, Gh.A.; Khalifa, N.A.

    2000-01-01

    The study involved the investigation and characterization of membranes prepared by graft copolymerization of acrylonitrile (AN) and vinyl acetate (VAc) binary monomers onto low density polyethylene (LDPE) and isotactic polypropylene (IPP). The mutual gamma-irradiation method was used as a grafting technique. The effects of grafting and chemical treatments on the thermal properties and crystallinity of prepared graft copolymer have been investigated using DSC, TGA and XRD. IR spectra recorded before and after grafting and also for the chemically treated membranes to elucidate the structural changes occurred due to grafting and chemical treatments

  15. Hypoksisk hepatitis

    DEFF Research Database (Denmark)

    Amadid, Hanan; Schiødt, Frank Vinholt

    2014-01-01

    Hypoxic hepatitis (HH), also known as ischaemic hepatitis or shock liver, is an acute liver injury caused by hepatic hypoxia. Cardiac failure, respiratory failure and septic shock are the main underlying conditions. In each of these conditions, several haemodynamic mechanisms lead to hepatic...... hypoxia. A shock state is observed in only 50% of cases. Thus, shock liver and ischaemic hepatitis are misnomers. HH can be a diagnostic pitfall but the diagnosis can be established when three criteria are met. Prognosis is poor and prompt identification and treatment of the underlying conditions...

  16. Radiation-induced grafting onto wool

    International Nuclear Information System (INIS)

    Muller-Schulte, D.

    1979-10-01

    Radiation-induced grafting tests were done on single wool fibres. Different vinyl monomers were used for this purpose and they were grafted in twenty different solvents which were selected for their swelling effiency and solvent parameters. The tests were done once with and once without the addition of water. The presence of water causes the polymer uptake to increase considerably. Formic acid/methanol and methanol were found to be the most suitable solvent systems, as they have the highest hydrogen-bond interaction effiency. The moisture uptake of wool depends on the hydrophily and hydrophoby of the grafted polymers. The single-fibre tests serve as a basis for analogous grafting tests on wool fabrics. The permanent- press was improved by graftng with hydrophoric polymers and polymers with a high glass-transition temperature [af

  17. Polyether-polyester graft copolymer

    Science.gov (United States)

    Bell, Vernon L. (Inventor)

    1987-01-01

    Described is a polyether graft polymer having improved solvent resistance and crystalline thermally reversible crosslinks. The copolymer is prepared by a novel process of anionic copolymerization. These polymers exhibit good solvent resistance and are well suited for aircraft parts. Previous aromatic polyethers, also known as polyphenylene oxides, have certain deficiencies which detract from their usefulness. These commercial polymers are often soluble in common solvents including the halocarbon and aromatic hydrocarbon types of paint thinners and removers. This limitation prevents the use of these polyethers in structural articles requiring frequent painting. In addition, the most popular commercially available polyether is a very high melting plastic. This makes it considerably more difficult to fabricate finished parts from this material. These problems are solved by providing an aromatic polyether graft copolymer with improved solvent resistance and crystalline thermally reversible crosslinks. The graft copolymer is formed by converting the carboxyl groups of a carboxylated polyphenylene oxide polymer to ionic carbonyl groups in a suitable solvent, reacting pivalolactone with the dissolved polymer, and adding acid to the solution to produce the graft copolymer.

  18. Host-Targeting Agents to Prevent and Cure Hepatitis C Virus Infection.

    Science.gov (United States)

    Zeisel, Mirjam B; Crouchet, Emilie; Baumert, Thomas F; Schuster, Catherine

    2015-11-02

    Chronic hepatitis C virus (HCV) infection is a major cause of liver cirrhosis and hepatocellular carcinoma (HCC) which are leading indications of liver transplantation (LT). To date, there is no vaccine to prevent HCV infection and LT is invariably followed by infection of the liver graft. Within the past years, direct-acting antivirals (DAAs) have had a major impact on the management of chronic hepatitis C, which has become a curable disease in the majority of DAA-treated patients. In contrast to DAAs that target viral proteins, host-targeting agents (HTAs) interfere with cellular factors involved in the viral life cycle. By acting through a complementary mechanism of action and by exhibiting a generally higher barrier to resistance, HTAs offer a prospective option to prevent and treat viral resistance. Indeed, given their complementary mechanism of action, HTAs and DAAs can act in a synergistic manner to reduce viral loads. This review summarizes the different classes of HTAs against HCV infection that are in preclinical or clinical development and highlights their potential to prevent HCV infection, e.g., following LT, and to tailor combination treatments to cure chronic HCV infection.

  19. Improved patency and reduced intimal hyperplasia in PTFE grafts with luminal immobilized heparin compared with standard PTFE grafts at six months in a sheep model.

    Science.gov (United States)

    Pedersen, G; Laxdal, E; Ellensen, V; Jonung, T; Mattsson, E

    2010-06-01

    The aim of this study was to compare the performance of polytetrafluoroethylene (PTFE) grafts with luminal coating of immobilized heparin to that of standard PTFE grafts at six months. Twenty-eight common carotid arteries in fourteen sheep were bypassed with heparin-coated PTFE grafts (6 mm diameter, 6 cm length) on one side and standard PTFE grafts on the other. The grafts were explanted after six months. The thickness of intimal hyperplasia (IH) in open grafts was measured with histomorphometrical methods. Two of 14 heparinized PTFE grafts and nine of 14 grafts in the control PTFE-group were occluded at explantation (P=0.006). Six-month patency rates for heparinized PTFE grafts and for standard PTFE grafts were 86% and 36%, respectively. Mean graft anastomotic IH thickness in open grafts were 0.074 mm for heparinized PTFE grafts and 0.259 mm for PTFE-grafts (P=0.006). PTFE grafts with luminal coating containing immobilized heparin had significantly better patency and recruited less intimal hyperplasia than standard PTFE grafts at six months.

  20. Polyether/Polyester Graft Copolymers

    Science.gov (United States)

    Bell, Vernon L., Jr.; Wakelyn, N.; Stoakley, D. M.; Proctor, K. M.

    1986-01-01

    Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

  1. Preparation of Dimethylaminoethylmethacrylate Grafted Polymeric Adsorbent by Using Radiation-Induced Grafting Technique for Removal of Anions

    International Nuclear Information System (INIS)

    Kavakli, P. A.

    2006-01-01

    The development of efficient separation and purification techniques is very important from industrial, environmental and economic points of view. Polymeric materials having polyfunctional groups such as carboxylic, amide, nitrile, iminodiacetic acid, amidoxime, and ammonium groups, etc., not only possess good hydrophilic properties, but also have good ion exchange properties which make them suitable for metal recovery from aqueous solutions. Radiation induced grafting is a powerful technique capable of controlling the introduction of various functional groups to the polymeric materials, keeping the original properties and especially the mechanical strength of the base material, and thus, allowing the synthesis of more stable polymeric adsorbents. The main objective of this study was to develop special polymeric adsorbents to remove NOx and PO 4 anions from aqueous systems. For this purpose, a novel nonwoven fabric was prepared by radiation-induced graft polymerization of imethylaminoethylmethacrylate (DMAEMA) onto polypropylene coated polyethylene nonwoven fabric. The trunk polymer was irradiated by electron beam at a voltage of 2 MeV and a current of 3 mA in a nitrogen atmosphere at dry-ice temperature at different doses. The degree of grafting was determined as a function of the total dose, monomer concentration, temperature, and reaction time. It was found that the degree of grafting of grafted polymer was greatly affected by reaction conditions. Grafting conditions were optimized, and about 150 % degree of grafting samples was used for further experiments. DMAEMA grafted polymer was later protonated by using acid solution to prepare adsorbent for the removal of anions. Adsorption experiments were performed in column mode for removal of phosphate. Approximately 2000 bed volumes of phosphate-free water can be produced from 10 ppb phosphate solution at high space velocity

  2. Aorto-hepatic bypass graft for repair of an inferior pancreatico-duodenal artery aneurysm associated with coeliac axis occlusion: A case report

    Directory of Open Access Journals (Sweden)

    Tom Hughes

    2016-01-01

    Conclusion: Surgical excision with bypass grafting from the supra-coeliac aorta, as reported by our team, represents a satisfactory management option in patients where interventional approaches have failed or are not appropriate.

  3. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Pedersoli, F., E-mail: fpedersoli@ukaachen.de; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Schmeding, M. [RWTH Aachen University Hospital, Clinic for General, Visceral and Transplant Surgery (Germany); Kuhl, C. K.; Bruners, P. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  4. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Pedersoli, F.; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M.; Schmeding, M.; Kuhl, C. K.; Bruners, P.

    2016-01-01

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  5. Radiation induced graft copolymerization of jute fibre

    International Nuclear Information System (INIS)

    Al-Siddique, F.R.; Khan, A.U.; Sheikh, R.A.

    1983-01-01

    Graft copolymerized jute fibres (GCJF) were prepared by γ-ray induced graft copolymerization of various monomers onto bleached and de-waxed jute samples. The effect of γ-ray dose on the tendency of various monomers to form graft co-polymer was studied. It was found that the tendency decreases as follows: methylmethacrylate (MMA)>acrylonitrile (AN)>styrene (STY)>vinylacetate (VA). When the effect of monomer concentration on the formation of graft co-polymer was studied, it was found that a mixture of AN and STY gave a higher amount of grafting than what was observed for STY or AN alone, when used at a comparable concentration. A study on the effect of concentration of methyl alcohol (a swelling agent for jute) on the tendency of the monomers to form graft co-polymer showed that although there is no effect when only AN is used, an appreciable effect is observed if AN is mixed with STY. In the later case the tendency of graft co-polymerization increases with the increase of CH 3 OH concentration. It was further observed that the increase of CH 3 OH also has a positive influence on MMA to form graft co-polymer in the range of 40-90% CH 3 OH. The affinity of GCJF towards moisture has been found to decrease with the increase of polymer loading onto jute. The presence of swelling agents during graft copolymer formation was also found to decrease the affinity of GCJF towards moisture. (author)

  6. Retrosternal friction-induced late disruption of the anastomotic site between Bentall's valved conduit and an aortic arch graft: report of a case.

    Science.gov (United States)

    Fukada, Johji; Morishita, Kiyofumi; Kawaharada, Nobuyoshi; Kurimoto, Yoshihiko; Muraki, Satoshi; Satsu, Takuma; Abe, Tomio

    2003-01-01

    We report a case of late mediastinal false aneurysm originating from disruption of the suture line between synthetic vascular grafts for aortic root and total aortic arch replacements. This aneurysm developed without any infection in a patient with Marfan's syndrome. To our knowledge, this event has never been reported before. The only possible cause of this disruption was that the monofilament suture was broken by continuous friction between the pointed anastomotic line and the sternum since the operation. The treatment options for this unusual event after extended synthetic graft replacement are discussed.

  7. The effect of monomer molecular weight on grafting reaction

    International Nuclear Information System (INIS)

    Wu Minghong; Ding Zhongli; Ma Zueteh

    1995-01-01

    In this paper, some condensed ethylene glycol acrylate monomers with different molecular weight being grafted to the PE film by means of pre-irradiation is reported. The effect of molecular weight of monomer on grafting reaction and the hydrophilicity of grafting sample have been discussed. The experimental results show: molar degrees of grafting decreased non-linearly with the increasement of molecular weight of monomer, the grafting reaction of polymer is greater effected by the swelling degree of PE film, the greater the swelling degree of grafting material, the higher the grating degree grafting is, the initial rate of grafting reaction decreased with the increasement of molecular weight of monomer. (author)

  8. Hepatic encephalopathy associated with hepatic lipidosis in llamas (Lama glama).

    Science.gov (United States)

    Pillitteri, C A; Craig, L E

    2013-01-01

    Hepatic encephalopathy has been listed as a differential for llamas displaying neurologic signs, but it has not been histopathologically described. This report details the neurologic histopathologic findings associated with 3 cases of hepatic lipidosis with concurrent neurologic signs and compares them to 3 cases of hepatic lipidosis in the absence of neurologic signs and 3 cases without hepatic lipidosis. Brain from all 3 llamas displaying neurologic signs contained Alzheimer type II cells, which were not detected in either subset of llamas without neurologic signs. Astrocytic immunohistochemical staining intensity for glial fibrillary acid protein was decreased in llamas with neurologic signs as compared to 2 of 3 llamas with hepatic lipidosis and without neurologic signs and to 2 of 3 llamas without hepatic lipidosis. Immunohistochemical staining for S100 did not vary between groups. These findings suggest that hepatic encephalopathy may be associated with hepatic lipidosis in llamas.

  9. Usefulness of screening ultrasonography for hepatocellular carcinoma detection: chronic hepatitis versus hepatic cirrhosis caused by hepatitis B virus

    International Nuclear Information System (INIS)

    Chang, Sam Uel; Choi, Don Gil; Lim, Jae Hoon

    2004-01-01

    To evaluate the usefulness of screening liver ultrasonography (US) for hepatocellular carcinoma (HCC) detection in patients with chronic hepatitis or hepatic cirrhosis caused by hepatitis B virus (HBV). A retrospective study was performed with 1,189 patients with clinical hepatopathy caused by HBV who underwent screening liver US for HCC detection at least twice. All patients were followed up with liver US examinations (mean, 8.3 times), CT, or MR for at least 3 months (range, 3-102 months; mean, 47 months) for the detection of HCC. The study population was divided into two groups: chronic hepatitis (n=492) and hepatic cirrhosis (n=697), which was further divided into two groups with (n=156) or without (n=541) evident shrinkage. The radiologic examinations that had detected HCC for the first time were analyzed and compared between the groups. Among 20 (4.1%) patients with chronic hepatitis and 132 (18.9%) patients with hepatic cirrhosis diagnosed as HCC, screening US was the modality of detection in 17 (85.0%) of 20 patients with chronic hepatitis and 76 (57.6%) of 132 patients with hepatic cirrhosis (p=0.038, Chi-square test). The detection rate of HCC on screening US between the chronic hepatitis and hepatic cirrhosis with evident shrinkage (51.4%, 19/37) showed a significant difference (p=0.027, Chi-square test). For chronic liver disease caused by HBV, screening US for HCC detection is more useful in patients with chronic hepatitis than with hepatic cirrhosis with evident shrinkage

  10. A multilayered polyurethane foam technique for skin graft immobilization.

    Science.gov (United States)

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (skin graft. This multilayered polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  11. [An experimental study of the healing of velour grafts].

    Science.gov (United States)

    Kobayashi, O

    1986-02-01

    An experimental study of implantation of velour grafts in the abdominal aorta or the external iliac artery of dogs was conducted with the object of evaluating the type of velour surface best fit for small-caliber artery implantation. Velour grafts measuring 4mm in diameter with differing velour surfaces were used as materials. Velour grafts now available on the market differ not only in velour surface but also in structure, notably in porosity and wall thickness. Hence each of the grafts used was reversed (i.e. inside out) and thus new grafts were prepared. These grafts were considered most suitable for making a comparative study of the effects of velour surface on healing. Macroscopic and histological findings revealed that each graft was good healing with the rate of patency as high as 84 percent. However, like Vasculour-D grafts, crimped grafts which preserve the crimp after implantation was significantly thicker at the internal valley than other grafts. Based on the findings of this experimental study non-crimped velour grafts were considered to be best fit for small-caliber artery implantation.

  12. Graft Copolymerization Of Methyl Methacrylate Onto Agave Cellulose

    International Nuclear Information System (INIS)

    Noor Afizah Rosli; Ishak Ahmad; Ibrahim Abdullah; Farah Hannan Anuar

    2014-01-01

    The grafting polymerization of methyl methacrylate (MMA) and Agave cellulose was prepared and the grafting reaction conditions were optimized by varying the reaction time and temperature, and ratio of monomer to cellulose. The resulting graft copolymers were characterized by Fourier transform infrared, X-ray diffraction analysis, thermogravimetric analysis, and scanning electron microscopy (SEM). The experimental results showed that the optimal conditions were at a temperature of 45 degree Celsius for 90 min with ratio monomer to cellulose at 1:1 (g/ g). An additional peak at 1738 cm -1 which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted cellulose, respectively. Grafting of MMA onto cellulose enhanced its thermal stability and SEM observation further furnished evidence of grafting MMA onto Agave cellulose with increasing cellulose diameter and surface roughness. (author)

  13. Grafted Cellulose Based Adsorbents for Selective Separation Purposes

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E; Wojnarovits, L [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary)

    2012-09-15

    The effect of high energy ionizing radiation on cotton-cellulose was studied. It was found that degradation of cellulose started at low doses, below 5 kGy, resulting in decrease in the degree of polymerization. However, the mechanical properties of cotton-cellulose samples only slightly changed with the dose up to 40 kGy. Acrylate type monomers were successfully grafted to cellulose by mutual and by pre-irradiation grafting technique. With both techniques the grafting yield increased with increasing dose and monomer concentration. In the case of pre-irradiation grafting the increase in grafting time also resulted in an increase in grafting percentage. Cotton-cellulose was functionalized using pre-irradiation grafting (PIG) and simultaneous grafting (SG) of glycidyl methacrylate (GMA). The adsorption properties of this material were further enhanced by {beta}-cyclodextrin (CD) immobilization. This molecule is known for its unique ability to form inclusion complexes among others with aromatic compounds like phenols, pesticide, dyes, etc. (author)

  14. Perinatal hepatitis B virus detection by hepatitis B virus-DNA analysis.

    OpenAIRE

    De Virgiliis, S; Frau, F; Sanna, G; Turco, M P; Figus, A L; Cornacchia, G; Cao, A

    1985-01-01

    Maternal transmission of hepatitis B virus infection in relation to the hepatitis B e antigen/antibody system and serum hepatitis B virus-DNA were evaluated. Results indicate that hepatitis B virus-DNA analysis can identify hepatitis B serum antigen positive mothers who may transmit infection to their offspring.

  15. An extended study of the phase separation between phospholipids and grafted polymers on a bilayer biomembrane

    Energy Technology Data Exchange (ETDEWEB)

    Benhamou, M; Joudar, I; Kaidi, H; Elhasnaoui, K; Ridouane, H; Qamar, H, E-mail: benhamou.mabrouk@gmail.com [Laboratoire de Physique des Polymeres et Phenomenes Critiques, Faculte des Sciences, Ben M' sik, PO Box 7955, Casablanca (Morocco)

    2011-06-01

    We re-examine here the phase separation between phospholipids and adsorbed polymer chains on a fluid membrane with a change in some suitable parameter (temperature). Our purpose is to quantify the significant effects of the solvent quality and of the polydispersity of adsorbed loops formed by grafted polymer chains on the segregation phenomenon. To this end, we elaborate on a theoretical model that allows us to derive the expression for the mixing free energy. From this, we extract the phase diagram shape in the composition-temperature plane. Our main conclusion is that the polymer chain condensation is very sensitive to the solvent quality and to the polydispersity of loops of adsorbed chains.

  16. MRI of double-bundle ACL reconstruction: evaluation of graft findings

    Energy Technology Data Exchange (ETDEWEB)

    Kiekara, Tommi; Paakkala, Antti [Tampere University Hospital, Medical Imaging Centre, Tampere (Finland); Jaervelae, Timo [Sports Clinic and Hospital Mehilaeinen, Tampere (Finland); Huhtala, Heini [University of Tampere, School of Health Sciences, Tampere (Finland)

    2012-07-15

    To demonstrate the magnetic resonance imaging (MRI) findings of double-bundle (DB) anterior cruciate ligament (ACL) reconstruction grafts. Sixty-six patients with DB ACL reconstruction were evaluated with MRI 2 years postoperatively. Graft thickness was measured separately by two musculoskeletal radiologists. The MRI findings of graft disruption, signal intensity (SI) changes, cystic degeneration, arthrofibrosis, and impingement were analyzed. The statistical significance of the association between MRI findings was calculated. The mean anteromedial (AM) graft thickness was reduced 9% and the mean posterolateral (PL) graft thickness was reduced 18% from the original graft thickness. Disruption was seen in 3% of AM grafts and 6% of PL grafts and a partial tear in 8 and 23%, respectively. Both grafts were disrupted in 3% of patients. Increased SI was seen in 14% of intact AM grafts and in 60% of partially torn AM grafts (p = 0.032). In PL grafts the increased SI was seen in 51% of the intact grafts and in 93% of the partially torn grafts (p = 0.005). Cystic degeneration was seen in 8% of AM grafts and in 5% of PL grafts. Diffuse arthrofibrosis was seen in 5% of patients and a localized cyclops lesion in 3% of patients. Impingement of the AM graft was seen in 8% of patients. Both grafts were disrupted in 3% of patients. Also, the frequencies of other complications were low. The use of orthogonal sequences in the evaluation of the PL graft SI seems to cause volume-averaging artefacts. (orig.)

  17. Noninvasive diagnosis of hepatic fibrosis in chronic hepatitis C

    OpenAIRE

    Stauber, Rudolf E; Lackner, Carolin

    2007-01-01

    Assessment of hepatic fibrosis is important for determining prognosis, guiding management decisions, and monitoring disease. Histological evaluation of liver biopsy specimens is currently considered the reference test for staging hepatic fibrosis. Since liver biopsy carries a small but significant risk, noninvasive tests to assess hepatic fibrosis are desirable. This editorial gives an overview on noninvasive methods currently available to determine hepatic fibrosis and their diagnostic accur...

  18. Hepatitis B Foundation

    Science.gov (United States)

    ... worldwide 2 Billion People have been infected with Hepatitis B Worldwide The Hepatitis B Foundation is working ... of people living with hepatitis B. Learn About Hepatitis B in 11 Other Languages . Resource Video See ...

  19. What Is Hepatitis?

    Science.gov (United States)

    ... Navigation Alt+1 Content Alt+2 What is hepatitis? Online Q&A Reviewed July 2016 Q: What ... Question and answer archives Submit a question World Hepatitis Day Posters: Eliminate hepatitis World Hepatitis Day 2017 ...

  20. Double-layered collagen graft to the radial forearm free flap donor sites without skin graft.

    Science.gov (United States)

    Park, Tae-Jun; Kim, Hong-Joon; Ahn, Kang-Min

    2015-12-01

    Radial forearm free flap is the most reliable flap for intraoral soft tissue reconstruction after cancer ablation surgery. However, unesthetic scar of the donor site and the need for a second donor site for skin graft are major disadvantages of the forearm flap. The purpose of this study was to report the clinical results of double-layered collagen graft to the donor site of the forearm free flap without skin graft. Twenty-two consecutive patients who underwent oral cancer ablation and forearm reconstruction between April 2010 and November 2013 were included in this study. Male to female ratio was 12:10, and average age was 61.0 years old (27-84). Double-layered collagen was grafted to the donor site of the forearm free flap and healed for secondary intention. Upper silicone had been trimmed at the periphery during secondary intention, and dry dressing was used. Postoperative scar healing and esthetic results and function were evaluated. An average follow-up period was 34.9 months. The scar area was decreased to 63.9 % in average. The complete healing was obtained between 1.5 and 3 months according to the defect size. There was no functional defect or impairment 3 months after operation. All patients were satisfied with the esthetic results. Three patients died of recurred cancer. Double-layered collagen graft was successfully performed in this study. Without the thigh skin graft, patients had experienced less painful postoperative healing periods and discomfort.

  1. GRAFT TAKES OF TOMATO ON OTHER SOLANACEOUS PLANTS

    Directory of Open Access Journals (Sweden)

    ANDRÉ RICARDO ZEIST

    2017-01-01

    Full Text Available This paper aimed to assess tomato grafting on different solanaceous species through two grafting methods. Scions were cut from cultivar Santa Cruz Kada seedlings. A fully randomized experimental design was carried out with treatments in a 9 x 2 factorial scheme. As rootstocks, four accessions of mini - tomatoes (0224 - 53, RVTC 57, RVTC 20 and 6889 - 50 - Solanum lycopersicum L; two species of wild tomato ( Solanum habrochaites var hirsutum ‘PI - 127826’ and Solanum pennellii ‘LA716’; other two tomato species [ Solanum, cocona ( Solanum sessiliflorum and physalis ( Physalis peruviana ] and a control with cultivar Santa Cruz Kada (auto - graft rootstocks were used. In addition, two grafting methods were evaluated full cleft and approach graft. Fifteen days after grafting, plants were assessed for graft - take percentage; root length; plant height; leaf number; foliar area; root, stem and leaf dry matter; and ratio between shoot and root dry matter. Based on the results, we may state rootstock and grafting interaction had effect on both graft - take rate and plant development. Overall, the studied plants should be recommended as rootstock, except for 6889 - 50 mini - tomato ( S. lycopersicum L. and S. pennellii . Full cleft grafting was most suitable for cocona and physalis, while the approach method showed better results for the mini - tomato accessions 0224 - 53, RVTC 57 and RVTC 20, as well as for S. habrochaites .

  2. Simultaneous splenectomy during liver transplantation augments anti-viral therapy in patients infected with hepatitis C virus.

    Science.gov (United States)

    Chu, Heng-Cheng; Hsieh, Chung-Bao; Hsu, Kuo-Feng; Fan, Hsiu-Lung; Hsieh, Tsai-Yuan; Chen, Teng-Wei

    2015-01-01

    Simultaneous splenectomy in liver transplantation (LT) is selectively indicated because of splenoportal venous thromboses and increased sepsis. Therefore, its impact should be further investigated. Of the 160 liver transplant patients, only 40 underwent simultaneous splenectomy. Clinicopathologic characteristics and outcomes were compared between the splenectomy and non-splenectomy group using retrospective analysis. Although the groups were similar and had no significant difference in the intra- and postoperative data, non-splenectomy group had more male patients. However, splenectomy group showed significantly higher platelet and leukocyte counts at 1 month and 6 months after the transplantation and higher hepatitis C virus anti-viral therapy completion. Furthermore, 3 patients developed portal or splenic vein thrombosis during the postoperative follow-up, but the overall survival rate did not significantly differ between these groups. Simultaneous splenectomy in LT can be safely performed, particularly in patients with hepatitis C virus cirrhosis, small-for-size grafts, hypersplenism, and ABO blood group incompatible (ABO - incompatible) LT. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. A short review of radiation-induced raft-mediated graft copolymerization: A powerful combination for modifying the surface properties of polymers in a controlled manner

    Science.gov (United States)

    Barsbay, Murat; Güven, Olgun

    2009-12-01

    Surface grafting of polymeric materials is attracting increasing attention as it enables the preparation of new materials from known and commercially available polymers having desirable bulk properties such as thermal stability, elasticity, permeability, etc., in conjunction with advantageous newly tailored surface properties such as biocompatibility, biomimicry, adhesion, etc. Ionizing radiation, particularly γ radiation is one of the most powerful tools for preparing graft copolymers as it generates radicals on most substrates. With the advent of living free-radical polymerization techniques, application of γ radiation has been extended to a new era of grafting; grafting in a controlled manner to achieve surfaces with tailored and well-defined properties. This report presents the current use of γ radiation in living free-radical polymerization and highlights the use of both techniques together as a combination to present an advance in the ability to prepare surfaces with desired, tunable and well-defined properties.

  4. A short review of radiation-induced raft-mediated graft copolymerization: A powerful combination for modifying the surface properties of polymers in a controlled manner

    International Nuclear Information System (INIS)

    Barsbay, Murat; Gueven, Olgun

    2009-01-01

    Surface grafting of polymeric materials is attracting increasing attention as it enables the preparation of new materials from known and commercially available polymers having desirable bulk properties such as thermal stability, elasticity, permeability, etc., in conjunction with advantageous newly tailored surface properties such as biocompatibility, biomimicry, adhesion, etc. Ionizing radiation, particularly γ radiation is one of the most powerful tools for preparing graft copolymers as it generates radicals on most substrates. With the advent of living free-radical polymerization techniques, application of γ radiation has been extended to a new era of grafting; grafting in a controlled manner to achieve surfaces with tailored and well-defined properties. This report presents the current use of γ radiation in living free-radical polymerization and highlights the use of both techniques together as a combination to present an advance in the ability to prepare surfaces with desired, tunable and well-defined properties.

  5. A short review of radiation-induced raft-mediated graft copolymerization: A powerful combination for modifying the surface properties of polymers in a controlled manner

    Energy Technology Data Exchange (ETDEWEB)

    Barsbay, Murat [Department of Chemistry, Hacettepe University, 06800 Beytepe, Ankara (Turkey)], E-mail: mbarsbay@hacettepe.edu.tr; Gueven, Olgun [Department of Chemistry, Hacettepe University, 06800 Beytepe, Ankara (Turkey)], E-mail: guven@hacettepe.edu.tr

    2009-12-15

    Surface grafting of polymeric materials is attracting increasing attention as it enables the preparation of new materials from known and commercially available polymers having desirable bulk properties such as thermal stability, elasticity, permeability, etc., in conjunction with advantageous newly tailored surface properties such as biocompatibility, biomimicry, adhesion, etc. Ionizing radiation, particularly {gamma} radiation is one of the most powerful tools for preparing graft copolymers as it generates radicals on most substrates. With the advent of living free-radical polymerization techniques, application of {gamma} radiation has been extended to a new era of grafting; grafting in a controlled manner to achieve surfaces with tailored and well-defined properties. This report presents the current use of {gamma} radiation in living free-radical polymerization and highlights the use of both techniques together as a combination to present an advance in the ability to prepare surfaces with desired, tunable and well-defined properties.

  6. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    Directory of Open Access Journals (Sweden)

    Fekete D.

    2015-01-01

    Full Text Available The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.. The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol. Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne. The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermelon. Some differences can be attributed to different environments, technological methods and to the type of rootstockscion combination. Lycopene is a strong antioxidant; therefore, we considered to examine the content change. Regardless of growing location, the lycopene concentration and the chroma (C* showed the best result in the case of interspecific rootstock. The result also showed that in two regions (Jászszentandrás, Cece we can find negative correlation between the lycopene concentration and the L* value of the flesh colour.

  7. Diagnostic value of liver scintigraphy in fulminant hepatitis and severe acute hepatitis

    International Nuclear Information System (INIS)

    Shiomi, Susumu; Ikeoka, Naoko; Minowa, Takami; Kuroki, Tetsuo; Harihara, Shigeyoshi; Yamamoto, Sukeo; Ochi, Hironobu; Monna, Takeyuki

    1985-01-01

    Liver scintigraphy was performed in 12 cases with fulminant hepatitis, in 8 cases with severe acute hepatitis and in 44 cases with acute hepatitis. Scintiphotoes of severe hepatitis showed reduction of liver size, marked visualization of the bone marrow and the spleen, so this pattern was useful to differentiate from acute hepatitis. Relative size of the liver calculated by A.L.I. (anterior liver index) showed significant reduction in severe hepatitis compared with that of acute hepatitis. Three of five patients with died of severe hepatitis showed high uptake in the lung and ribs, but none of fifteen patients with severe hepatitis who recovered showed the abnormal accumulation in the lung and in the ribs. (author)

  8. Hepatitis C

    Science.gov (United States)

    ... an inflammation of the liver. One type, hepatitis C, is caused by the hepatitis C virus (HCV). It usually spreads through contact with ... childbirth. Most people who are infected with hepatitis C don't have any symptoms for years. If ...

  9. Serum Hepatitis C virus and hepatitis B surface antigenaemia in ...

    African Journals Online (AJOL)

    Acute hepatitis is common in Nigeria and hepatitis B virus (HBV) infection has been a major aetiological factor. However, the role of Hepatitis C virus (HCV) infection is yet undetermined. Forty-five consecutive Nigerian patients with acute Icteric hepatitis (AIH) attending the Medical Clinic of the University College Hospital, ...

  10. Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    LENUS (Irish Health Repository)

    Ong, J C Y

    2012-06-01

    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

  11. Promising Technique for Facial Nerve Reconstruction in Extended Parotidectomy

    Directory of Open Access Journals (Sweden)

    Ithzel Maria Villarreal

    2015-11-01

    Full Text Available Introduction: Malignant tumors of the parotid gland account scarcely for 5% of all head and neck tumors. Most of these neoplasms have a high tendency for recurrence, local infiltration, perineural extension, and metastasis. Although uncommon, these malignant tumors require complex surgical treatment sometimes involving a total parotidectomy including a complete facial nerve resection. Severe functional and aesthetic facial defects are the result of a complete sacrifice or injury to isolated branches becoming an uncomfortable distress for patients and a major challenge for reconstructive surgeons.   Case Report: A case of a 54-year-old, systemically healthy male patient with a 4 month complaint of pain and swelling on the right side of the face is presented. The patient reported a rapid increase in the size of the lesion over the past 2 months. Imaging tests and histopathological analysis reported an adenoid cystic carcinoma. A complete parotidectomy was carried out with an intraoperative notice of facial nerve infiltration requiring a second intervention for nerve and defect reconstruction. A free ALT flap with vascularized nerve grafts was the surgical choice. A 6 month follow-up showed partial facial movement recovery and the facial defect mended.   Conclusion:  It is of critical importance to restore function to patients with facial nerve injury.  Vascularized nerve grafts, in many clinical and experimental studies, have shown to result in better nerve regeneration than conventional non-vascularized nerve grafts. Nevertheless, there are factors that may affect the degree, speed and regeneration rate regarding the free fasciocutaneous flap. In complex head and neck defects following a total parotidectomy, the extended free fasciocutaneous ALT (anterior-lateral thigh flap with a vascularized nerve graft is ideally suited for the reconstruction of the injured site.  Donor–site morbidity is low and additional surgical time is minimal

  12. Promising Technique for Facial Nerve Reconstruction in Extended Parotidectomy.

    Science.gov (United States)

    Villarreal, Ithzel Maria; Rodríguez-Valiente, Antonio; Castelló, Jose Ramon; Górriz, Carmen; Montero, Oscar Alvarez; García-Berrocal, Jose Ramon

    2015-11-01

    Malignant tumors of the parotid gland account scarcely for 5% of all head and neck tumors. Most of these neoplasms have a high tendency for recurrence, local infiltration, perineural extension, and metastasis. Although uncommon, these malignant tumors require complex surgical treatment sometimes involving a total parotidectomy including a complete facial nerve resection. Severe functional and aesthetic facial defects are the result of a complete sacrifice or injury to isolated branches becoming an uncomfortable distress for patients and a major challenge for reconstructive surgeons. A case of a 54-year-old, systemically healthy male patient with a 4 month complaint of pain and swelling on the right side of the face is presented. The patient reported a rapid increase in the size of the lesion over the past 2 months. Imaging tests and histopathological analysis reported an adenoid cystic carcinoma. A complete parotidectomy was carried out with an intraoperative notice of facial nerve infiltration requiring a second intervention for nerve and defect reconstruction. A free ALT flap with vascularized nerve grafts was the surgical choice. A 6 month follow-up showed partial facial movement recovery and the facial defect mended. It is of critical importance to restore function to patients with facial nerve injury. Vascularized nerve grafts, in many clinical and experimental studies, have shown to result in better nerve regeneration than conventional non-vascularized nerve grafts. Nevertheless, there are factors that may affect the degree, speed and regeneration rate regarding the free fasciocutaneous flap. In complex head and neck defects following a total parotidectomy, the extended free fasciocutaneous ALT (anterior-lateral thigh) flap with a vascularized nerve graft is ideally suited for the reconstruction of the injured site. Donor-site morbidity is low and additional surgical time is minimal compared with the time of a single ALT flap transfer.

  13. Novel anterior cruciate ligament graft fixation device reduces slippage

    Directory of Open Access Journals (Sweden)

    Lopez MJ

    2013-05-01

    Full Text Available Mandi J Lopez,1 Allen Borne,2 W Todd Monroe,3 Prakash Bommala,1 Laura Kelly,1 Nan Zhang11Laboratory for Equine and Comparative Orthopedic Research, Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, 2Louisiana State University, New Orleans Health Sciences Center, School of Medicine, New Orleans, 3Department of Biological and Agricultural Engineering, Agricultural Center, Louisiana State University, Baton Rouge, LA, USAAbstract: Clinically significant laxity occurs in 10%–30% of knees after anterior cruciate ligament reconstruction. Graft slippage and tension loss at the hamstring graft tibial fixation site during and after reconstruction surgery contribute to postoperative joint laxity and are detrimental to long-term knee stability and graft properties. Limiting graft slippage will reduce associated complications. We sought to compare the in vitro mechanical properties and in vivo joint stabilization, postoperative limb use, and graft incorporation of the novel GraftGrab™ (GG device designed to reduce hamstring graft tibial fixation slippage with the commercially available bioabsorbable Bio-Post™ and spiked washer (BP. Mechanical testing was performed on canine tibia-hamstring graft constructs to quantify initial fixation properties. In vivo joint stabilization, postoperative limb use and graft incorporation of hamstring graft reconstructions were determined in a canine model. Outcomes included tibial translation and ground reaction forces preoperatively and 4 and 8 weeks postoperatively, three-dimensional graft and bone tunnel dimensions at the latter two time points, and graft-bone microstructure, as well as mechanical properties 8 weeks after implantation. Immediately after fixation, all grafts slipped from the BP constructs versus about 30% of GG constructs. In vivo limb use remained low, and tibial translation increased with time in the BP cohort. These results together

  14. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  15. Hepatitis A

    Science.gov (United States)

    ... is an inflammation of the liver. One type, hepatitis A, is caused by the hepatitis A virus (HAV). The disease spreads through contact with ... suggest medicines to help relieve your symptoms. The hepatitis A vaccine can prevent HAV. Good hygiene can also ...

  16. Corneal graft reversal: Histopathologic report of two cases

    OpenAIRE

    Qahtani, Abdullah A.; Alkatan, Hind M.

    2014-01-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for faile...

  17. The functional hepatic volume assessed by 99mTc-GSA hepatic scintigraphy

    International Nuclear Information System (INIS)

    Wu, Jin; Ishikawa, Nobuyoshi; Takeda, Tohoru; Pan, Xiao-Qing; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji; Tanaka, Yumiko; Hatakeyama, Rokurou.

    1995-01-01

    The accuracy of measurement of the functional hepatic volume by single photon emission computed tomography (SPECT) with 99m Tc-galactosyl serum albumin ( 99m Tc-GSA) was evaluated. 99m Tc-GSA planar scintigraphic images were obtained dynamically and the hepatic SPECT imaging was then performed in 25 patients with hepatobiliary tumors. The patients were divided into 4 groups with normal hepatic function, mild, moderate and severe hepatic dysfunction. The functional hepatic volume determined by SPECT was compared with the morphological hepatic volume determined by computed tomography. The ratio of the hepatic volumes obtained by the two methods was calculated. The mean hepatic volume ratio was 96.6±2.3% in the normal hepatic function group and 95.9±2.2% in the mild dysfunction group (n.s.). In both the moderate and severe hepatic dysfunction groups, the hepatic volume ratio was smaller than that in the normal group (87.9±5.2%, p 15 (r=0.83, p 15 (r=0.74, p 15 (r=0.75, p 99m Tc-GSA faithfully reflects the functioning hepatocyte mass. 99m Tc-GSA scintigraphy and hepatic SPECT therefore provide information regarding global and regional reserve hepatic function. (author)

  18. Electrochemical signature of the grafting of diazonium salts: A probing parameter for monitoring the electro-addressed functionalization of devices

    Energy Technology Data Exchange (ETDEWEB)

    Le Floch, Fabien [LETI/DIHS/LCMS, CEA-Grenoble 17 rue des martyrs, 38054 Grenoble cedex 9 (France); Simonato, Jean-Pierre [LITEN/DTNM/LCH, CEA-Grenoble 17 rue des martyrs, 38054 Grenoble cedex 9 (France); Bidan, Gerard [INAC/DIR, CEA-Grenoble 17 rue des martyrs, 38054 Grenoble cedex 9 (France)], E-mail: gerard.bidan@cea.fr

    2009-04-15

    The reciprocal influence of the phenylsubstituents and diazonium groups allows to monitor the diazonium reactivity and to electrochemically detect the grafting reaction. Extended understanding concerning the grafting of para substituted tetrafluoroborate aryl diazonium salts p-(R-Ph-N{sub 2}{sup +}, BF{sub 4}{sup -}) was obtained by studying comparatively four compounds (R = NO{sub 2}, NEt{sub 2}, NHPh, NPh{sub 2}) by electrochemistry. For R = NEt{sub 2}, the grafted molecules showed no reversible electroactivity whereas for the aminophenyl substituents, the first oxidation process induced chemical modification of the deposited layers before being totally reversible. The compound with electron withdrawing group (NO{sub 2}) was the only one able to create spontaneous covalent bounding with the glassy carbon electrode (GCE). We observed that the substituent directly acts upon the diazonium reactivity. This effect can be directly monitored through the potential onset value of the diazonium reduction. In addition, the elimination of the diazonium group during electrografting induces a cathodic shift of the electroactivity of the aminodiphenyl and aminotriphenyl groups covalently attached onto the carbon electrode surface. The shift between these electrochemical values may be considered as a signature of the grafting reaction.

  19. Alteration of hepatic structure and oxidative stress induced by intravenous nanoceria

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, Michael T., E-mail: mttsen01@louisville.edu [Dept of Anatomical Sciences and Neurobiology, University of Louisville, Louisville, Kentucky (United States); Lu, Xiaoqin, E-mail: x0lu0003@louisville.edu [Dept of Anatomical Sciences and Neurobiology, University of Louisville, Louisville, Kentucky (United States); Duan, Xiaoxian, E-mail: x0duan02@louisville.edu [Dept of Anatomical Sciences and Neurobiology, University of Louisville, Louisville, Kentucky (United States); Hardas, Sarita S., E-mail: sarita.hardas@uky.edu [Dept. of Chemistry, University of Kentucky, Lexington, Kentucky (United States); Sultana, Rukhsana, E-mail: rsult2@uky.edu [Dept. of Chemistry, University of Kentucky, Lexington, Kentucky (United States); Wu, Peng, E-mail: peng.wu@uky.edu [Dept of Chemical and Materials Engineering, University of Kentucky, Lexington, Kentucky (United States); Unrine, Jason M., E-mail: jason.unrine@uky.edu [Dept of Plant and Soil Sciences, University of Kentucky, Lexington, Kentucky (United States); Graham, Uschi, E-mail: graham@caer.uky.edu [Center for Applied Energy Research, University of Kentucky, Lexington, Kentucky (United States); Butterfield, D. Allan, E-mail: dabcns@uky.edu [Dept. of Chemistry, University of Kentucky, Lexington, Kentucky (United States); Grulke, Eric A., E-mail: eric.grulke@uky.edu [Dept of Chemical and Materials Engineering, University of Kentucky, Lexington, Kentucky (United States); Yokel, Robert A., E-mail: ryokel@email.uky.edu [Department of Pharmaceutical Sciences, University of Kentucky, Lexington, Kentucky (United States)

    2012-04-15

    Beyond the traditional use of ceria as an abrasive, the scope of nanoceria applications now extends into fuel cell manufacturing, diesel fuel additives, and for therapeutic intervention as a putative antioxidant. However, the biological effects of nanoceria exposure have yet to be fully defined, which gave us the impetus to examine its systemic biodistribution and biological responses. An extensively characterized nanoceria (5 nm) dispersion was vascularly infused into rats, which were terminated 1 h, 20 h or 30 days later. Light and electron microscopic tissue characterization was conducted and hepatic oxidative stress parameters determined. We observed acute ceria nanoparticle sequestration by Kupffer cells with subsequent bioretention in parenchymal cells as well. The internalized ceria nanoparticles appeared as spherical agglomerates of varying dimension without specific organelle penetration. In hepatocytes, the agglomerated nanoceria frequently localized to the plasma membrane facing bile canaliculi. Hepatic stellate cells also sequestered nanoceria. Within the sinusoids, sustained nanoceria bioretention was associated with granuloma formations comprised of Kupffer cells and intermingling CD3{sup +} T cells. A statistically significant elevation of serum aspartate aminotransferase (AST) level was seen at 1 and 20 h, but subsided by 30 days after ceria administration. Further, elevated apoptosis was observed on day 30. These findings, together with increased hepatic protein carbonyl levels on day 30, indicate ceria-induced hepatic injury and oxidative stress, respectively. Such observations suggest a single vascular infusion of nanoceria can lead to persistent hepatic retention of particles with possible implications for occupational and therapeutic exposures. -- Highlights: ► Time course study on nanoceria induced hepatic alterations in rats. ► Serum AST elevation indicated acute hepatotoxicity. ► Ceria is retained for up to 30 days in Kupffer cells

  20. Cost-effectiveness of hepatitis A vaccination for individuals with chronic hepatitis C.

    Science.gov (United States)

    Chapko, Michael K; Yee, Helen S; Monto, Alexander; Dominitz, Jason A

    2010-02-17

    The incidence of hepatitis A infection in the United States has decreased dramatically in recent years because of childhood immunization programs. A decision analysis of the cost-effectiveness of hepatitis A vaccination for adults with hepatitis C was conducted. No vaccination strategy is cost-effective for adults with hepatitis C using the recent lower anticipated hepatitis A incidence, private sector costs, and a cost-effectiveness criterion of $100,000/QALY. Vaccination is cost-effective only for individuals who have cleared the hepatitis C virus when Department of Veterans Affairs costs are used. The recommendation to vaccinate adults with hepatitis C against hepatitis A should be reconsidered. Published by Elsevier Ltd.

  1. Hepatitis E virus and fulminant hepatitis--a virus or host-specific pathology?

    Science.gov (United States)

    Smith, Donald B; Simmonds, Peter

    2015-04-01

    Fulminant hepatitis is a rare outcome of infection with hepatitis E virus. Several recent reports suggest that virus variation is an important determinant of disease progression. To critically examine the evidence that virus-specific factors underlie the development of fulminant hepatitis following hepatitis E virus infection. Published sequence information of hepatitis E virus isolates from patients with and without fulminant hepatitis was collected and analysed using statistical tests to identify associations between virus polymorphisms and disease outcome. Fulminant hepatitis has been reported following infection with all four hepatitis E virus genotypes that infect humans comprising multiple phylogenetic lineages within genotypes 1, 3 and 4. Analysis of virus sequences from individuals infected by a common source did not detect any common substitutions associated with progression to fulminant hepatitis. Re-analysis of previously reported associations between virus substitutions and fulminant hepatitis suggests that these were probably the result of sampling biases. Host-specific factors rather than virus genotype, variants or specific substitutions appear to be responsible for the development of fulminant hepatitis. © 2014 The Authors. Liver International Published by John Wiley & Sons Ltd.

  2. Vascularized fibular graft in infected tibial bone loss

    Directory of Open Access Journals (Sweden)

    C Cheriyan Kovoor

    2011-01-01

    Full Text Available Background : The treatment options of bone loss with infections include bone transport with external fixators, vascularized bone grafts, non-vascularized autogenous grafts and vascularized allografts. The research hypothesis was that the graft length and intact ipsilateral fibula influenced hypertrophy and stress fracture. We retrospectively studied the graft hypertrophy in 15 patients, in whom vascularized fibular graft was done for post-traumatic tibial defects with infection. Materials and Methods : 15 male patients with mean age 33.7 years (range 18 - 56 years of post traumatic tibial bone loss were analysed. The mean bony defect was 14.5 cm (range 6.5 - 20 cm. The mean length of the graft was 16.7 cm (range 11.5 - 21 cm. The osteoseptocutaneous flap (bone flap with attached overlying skin flap from the contralateral side was used in all patients except one. The graft was fixed to the recipient bone at both ends by one or two AO cortical screws, supplemented by a monolateral external fixator. A standard postoperative protocol was followed in all patients. The hypertrophy percentage of the vascularized fibular graft was calculated by a modification of the formula described by El-Gammal. The followup period averaged 46.5 months (range 24 - 164 months. The Pearson correlation coefficient (r was worked out, to find the relationship between graft length and hypertrophy. The t-test was performed to find out if there was any significant difference in the graft length of those who had a stress fracture and those who did not and to find out whether there was any significant difference in hypertrophy with and without ipsilateral fibula union. The Chi square test was performed to identify whether there was any association between the stress fracture and the fibula union. Given the small sample size we have not used any statistical analysis to determine the relation between the percentage of the graft hypertrophy and stress fracture. Results : Graft

  3. Hyaluronic Acid Graft Copolymers with Cleavable Arms as Potential Intravitreal Drug Delivery Vehicles.

    Science.gov (United States)

    Borke, Tina; Najberg, Mathie; Ilina, Polina; Bhattacharya, Madhushree; Urtti, Arto; Tenhu, Heikki; Hietala, Sami

    2018-01-01

    Treatment of retinal diseases currently demands frequent intravitreal injections due to rapid clearance of the therapeutics. The use of high molecular weight polymers can extend the residence time in the vitreous and prolong the injection intervals. This study reports a water soluble graft copolymer as a potential vehicle for sustained intravitreal drug delivery. The copolymer features a high molecular weight hyaluronic acid (HA) backbone and poly(glyceryl glycerol) (PGG) side chains attached via hydrolysable ester linkers. PGG, a polyether with 1,2-diol groups in every repeating unit available for conjugation, serves as a detachable carrier. The influence of synthesis conditions and incubation in physiological media on the molecular weight of HA is studied. The cleavage of the PGG grafts from the HA backbone is quantified and polymer-from-polymer release kinetics are determined. The biocompatibility of the materials is tested in different cell cultures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Blood lipids analysis in patients with hepatitis and hepatic fibrosis

    International Nuclear Information System (INIS)

    Si Jianhong

    2007-01-01

    Objective: To investigate the correlationship between blood hepatic fibrosis markers and blood lipids levels. Methods: Serum hepatic fibrosis markers (HA, PC III, IV-C, LN) levels were determined with RIA and serum lipids (TG, TCh HDL; LDL, apoA1, apoB) were measured with biochemical methods in 98 patients with hepatitis in various stages and 50 controls. Liver biopsy was done in all the hepatitis patients. Results: Hepatic fibrosis was classified into 5 grades (S0-S4) according to the pathology shown in the biopsy specimen. The serum lipid levels decreased along with the increase of severity of fibrosis from S0 to S4. Levels in S4 patients were significantly lower than those in controls (P 0.05). Conclusion: The serum hepatic fibrosis markers levels increased and lipids levels decreased along with the progress of hepatitis from acute to cirrhosis. (authors)

  5. Hepatic Encephalopathy

    Science.gov (United States)

    ... Caregiver Support Caregiver Stories Home › What is Hepatic Encephalopathy? Why Your Liver is Important The Connection Between HE and Liver ... Why it’s Important to Treat HE Symptoms of Liver Failure Glossary of terms ... is Hepatic Encephalopathy? Hepatic Encephalopathy, sometimes referred to as portosystemic encephalopathy ...

  6. Hepatitis B immunisation for newborn infants of hepatitis B surface antigen-positive mothers

    DEFF Research Database (Denmark)

    Lee, C; Gong, Yanzhang; Brok, J

    2006-01-01

    Hepatitis B vaccine and hepatitis B immunoglobulin are considered for newborn infants of HBsAg-positive mothers to prevent hepatitis B infection.......Hepatitis B vaccine and hepatitis B immunoglobulin are considered for newborn infants of HBsAg-positive mothers to prevent hepatitis B infection....

  7. How hepatitis D virus can hinder the control of hepatitis B virus.

    Directory of Open Access Journals (Sweden)

    Maria Xiridou

    Full Text Available BACKGROUND: Hepatitis D (or hepatitis delta virus is a defective virus that relies on hepatitis B virus (HBV for transmission; infection with hepatitis D can occur only as coinfection with HBV or superinfection of an existing HBV infection. Because of the bond between the two viruses, control measures for HBV may have also affected the spread of hepatitis D, as evidenced by the decline of hepatitis D in recent years. Since the presence of hepatitis D is associated with suppressed HBV replication and possibly infectivity, it is reasonable to speculate that hepatitis D may facilitate the control of HBV. METHODOLOGY AND PRINCIPAL FINDINGS: We introduced a mathematical model for the transmission of HBV and hepatitis D, where individuals with dual HBV and hepatitis D infection transmit both viruses. We calculated the reproduction numbers of single HBV infections and dual HBV and hepatitis D infections and examined the endemic prevalences of the two viruses. The results show that hepatitis D virus modulates not only the severity of the HBV epidemic, but also the impact of interventions for HBV. Surprisingly we find that the presence of hepatitis D virus may hamper the eradication of HBV. Interventions that aim to reduce the basic reproduction number of HBV below one may not be sufficient to eradicate the virus, as control of HBV depends also on the reproduction numbers of dual infections. CONCLUSIONS AND SIGNIFICANCE: For populations where hepatitis D is endemic, plans for control programs ignoring the presence of hepatitis D may underestimate the HBV epidemic and produce overoptimistic results. The current HBV surveillance should be augmented with monitoring of hepatitis D, in order to improve accuracy of the monitoring and the efficacy of control measures.

  8. Autologous fat graft and bone marrow-derived mesenchymal stem cells assisted fat graft for treatment of Parry-Romberg syndrome.

    Science.gov (United States)

    Jianhui, Zhao; Chenggang, Yi; Binglun, Lu; Yan, Han; Li, Yang; Xianjie, Ma; Yingjun, Su; Shuzhong, Guo

    2014-09-01

    Progressive facial hemiatrophy, also called Parry-Romberg syndrome (PRS), is characterized by slowly progressive atrophy of one side of the face and primarily involves the subcutaneous tissue and fat. The restoration of facial contour and symmetry in patients affected by PRS still remains a challenge clinically. Fat graft is a promising treatment but has some shortcomings, such as unpredictability and low rate of graft survival due to partial necrosis. To obviate these disadvantages, fat graft assisted by bone marrow-derived mesenchymal stem cells (BMSCs) was used to treat PRS patients and the outcome was evaluated in comparison with the conventional treatment by autologous fat graft. Autologous fat graft was harvested by tumescent liposuction. Bone marrow-derived mesenchymal stem cells were then isolated by human Lymphocytes Separation Medium through density gradient centrifugation. Twenty-six patients were treated with autologous fat graft only (group A), whereas 10 other patients were treated with BMSC-assisted fat graft (group B). The Coleman technique was applied in all fat graft injections. The follow-up period was 6 to 12 months in this study, In group A, satisfactory outcome judged by symmetrical appearances was obtained with 1 injection in 12 patients, 2 injections in 8 patients, and 3 injections in 4 patients. However, the result of 1 patient was not satisfactory and 1 patient was overcorrected. In group B, 10 patients obtained satisfactory outcomes and almost reached symmetry by 1 injection. No complications (infection, hematoma, or subcutaneous mass) were observed. The results suggest that BMSC-assisted fat graft is effective and safe for soft tissue augmentation and may be superior to conventional lipoinjection. Additional study is necessary to further evaluate the efficacy of this technique.

  9. Primary contraction of skin grafts: a porcine preliminary study

    Directory of Open Access Journals (Sweden)

    Alexander Bogdanov Berezovsky

    2015-03-01

    Full Text Available Aim: Skin grafting is a common clinical practice for plastic surgeons, yet primary contraction of these grafts is a neglected topic. This study was designed to investigate primary contraction and introduce the shape of skin graft as a possible factor that modifies primary contraction behavior, using porcine models. Methods: In the first series, full-thickness skin grafts (FTSGs and split-thickness skin grafts (STSGs were compared. In a second series, how the shape of the skin graft affected the degree of contraction was examined. Results: The mean percentage of FTSG shrinkage was 12.04%, and the median was 12.18%. The mean percentage of STSG shrinkage was 6.87%, and the median was 5%. Circle-shaped and square-shaped FTSGs showed mean/median graft shrinkage of 5.83%/6.93% and 4.15%/3.75%, respectively. In STSGs, the circle-shaped and square-shaped grafts had mean/median graft shrinkage of 1.07%/0% and 0.31%/0%, respectively. Conclusion: Our preliminary report revealed an expected greater shrinkage of FTSGs compared with STSGs. Furthermore, in a limited number of specimens, the shape of the skin graft seemed to affect the primary contraction of the STSGs.

  10. Calcification of a Synthetic Renovascular Graft in a Child

    Directory of Open Access Journals (Sweden)

    D.S.T. Chong

    Full Text Available : Introduction: Vascular grafts, especially in paediatric cases, need to be durable. Common failures such as thrombosis are well documented with research efforts directed towards them. However, there are lesser known causes of graft failure, such as graft calcification, and these also require further research focus. Report: A paediatric case is described in which a synthetic renovascular graft, implanted for mid-aortic syndrome, became calcified, necessitating surgical intervention to resolve graft malfunction. Significant calcification in the limb of a bifurcated polyethylene terephthalate graft was found to be the cause of resistant stenosis and refractory hypertension. Histology conducted on the explanted limb showed the presence of multinuclear giant cells, indicating a chronic foreign body response. Discussion: Calcification of vascular grafts is probably more common than previously recognised. Stenosis typically resistant to angioplasty may result in the long term and thus leading to surgical intervention. In young children, this is suboptimal as these grafts need to last throughout adulthood. Explanted prosthetic grafts should be sent to specialist registries such as that in Strasbourg to be optimally assessed so that contributory factors can be identified. Keywords: Renovascular graft, Paediatric, Calcification

  11. Travelers' Health: Hepatitis C

    Science.gov (United States)

    ... Chapter 3 - Hepatitis B Chapter 3 - Hepatitis E Hepatitis C Deborah Holtzman INFECTIOUS AGENT Hepatitis C virus ( ... mother to child. Map 3-05. Prevalence of hepatitis C virus infection 1 PDF Version (printable) 1 ...

  12. Travelers' Health: Hepatitis A

    Science.gov (United States)

    ... 3 - Helminths, Soil-Transmitted Chapter 3 - Hepatitis B Hepatitis A Noele P. Nelson INFECTIOUS AGENT Hepatitis A ... hepatitis/HAV Table 3-02. Vaccines to prevent hepatitis A VACCINE TRADE NAME (MANUFACTURER) AGE (Y) DOSE ...

  13. Travelers' Health: Hepatitis B

    Science.gov (United States)

    ... Chapter 3 - Hepatitis A Chapter 3 - Hepatitis C Hepatitis B Francisco Averhoff INFECTIOUS AGENT Hepatitis B virus ( ... progression of disease. Map 3-04. Prevalence of hepatitis B virus infection 1 PDF Version (printable) 1 ...

  14. Permeability of solutes through cellophanes grafted with vinyl monomers. II. Diffusion of potassium chloride through cellophanes grafted with acrylic acid

    International Nuclear Information System (INIS)

    Takigami, S.; Maeda, Y.; Nakamura, Y.

    1979-01-01

    The permeability behavior of potassium chloride through cellophane grafted with acrylic acid by a γ-irradiation method was studied by the theoretical equation derived from the phenomenological equation and compared with the results of Donnan membrane equilibrium. It was shown that the permeation of potassium chloride through the grafted cellophanes exhibited behavior typical of a polyionic membrane for grafts of more than 55% but depended on the permeability of both cellophane and graft regions for lower percents of grafting. It was found that the dominant factor affecting the permeation of potassium chloride was an effective concentration of fixed charge in the membrane. 5 figures, 2 tables

  15. Changing Epidemiology of Hepatitis A and Hepatitis E Viruses in China, 1990-2014.

    Science.gov (United States)

    Ren, Xiang; Wu, Peng; Wang, Liping; Geng, Mengjie; Zeng, Lingjia; Zhang, Jun; Xia, Ningshao; Lai, Shengjie; Dalton, Harry R; Cowling, Benjamin J; Yu, Hongjie

    2017-02-01

    We compared the epidemiology of hepatitis A and hepatitis E cases in China from 1990-2014 to better inform policy and prevention efforts. The incidence of hepatitis A cases declined dramatically, while hepatitis E incidence increased. During 2004-2014, hepatitis E mortality rates surpassed those of hepatitis A.

  16. Hepatitis C: Clinical Trials

    Science.gov (United States)

    ... and Public Home » Hepatitis C » Treatment Decisions Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... can I find out about participating in a hepatitis C clinical trial? Many trials are being conducted ...

  17. Hepatitis C: Mental Health

    Science.gov (United States)

    ... the Public Home Hepatitis A Hepatitis B Hepatitis C Hepatitis C Home Getting Tested Just Diagnosed Treatment Choice Program ... Pain Mental Health Sex and Sexuality (for Hepatitis C) Success Stories FAQs For Health Care Providers Provider ...

  18. Frequency of hepatitis B in asymptomatic patients of district Headquarter hospital Kotli, Azad Kashmir

    International Nuclear Information System (INIS)

    Sarwar, J.; Ahmad, W.; Saleem, M.; Jamshed, F.; Gul, N.; Idrees, M.

    2010-01-01

    Background: Hepatitis B is prevalent throughout the world including Pakistan. A large proportion of patients suffering from Hepatitis B may be asymptomatic and can transmit the disease to healthy population. Objectives of this study were to estimate the frequency of Hepatitis B in asymptomatic adult population coming to District Headquarter Hospital Kotli, Azad Kashmir and to determine the risk factors associated with its transmission. Methods: This was a cross-sectional study extending from January to December 2008. Subjects were randomly selected from those who attended the medial OPD of DHQ Hospital Kotli, Azad Kashmir for non-Hepatitis related problems. Both males and females between the ages of 15-80 years were included in the study. Blood samples taken from selected subjects were analysed for Hepatitis B surface antigen (HBsAg) by Immuno chromatographic kit methods (ICT). Hepatitis B positive samples were further confirmed by third generation ELIZA. The patients thus confirmed were interrogated for different risk factors associated with transmission of Hepatitis B. Results: A total of 9,564 patients were analysed. Out of them 4230 (44.22%) were males and 5334 (55.77%) were females. Overall 141 (1.47%) patients were positive for HBSAg, 71 (1.68%) males and 70 (1.31%) females. Patients between 21-30 years of age were most commonly effected (35.46%, n=50). Blood transfusion was the most common risk factor (24.82%, n=35) associated with Hepatitis B transmission followed by dental procedures (14.18%, n=20). Conclusion: Frequency of Hepatitis B in asymptomatic people in this study was quite high. Blood transfusions and dental procedures were the most common risk factors associated with the transmission of Hepatitis B. (author)

  19. Dynamic, nondestructive imaging of a bioengineered vascular graft endothelium.

    Directory of Open Access Journals (Sweden)

    Bryce M Whited

    Full Text Available Bioengineering of vascular grafts holds great potential to address the shortcomings associated with autologous and conventional synthetic vascular grafts used for small diameter grafting procedures. Lumen endothelialization of bioengineered vascular grafts is essential to provide an antithrombogenic graft surface to ensure long-term patency after implantation. Conventional methods used to assess endothelialization in vitro typically involve periodic harvesting of the graft for histological sectioning and staining of the lumen. Endpoint testing methods such as these are effective but do not provide real-time information of endothelial cells in their intact microenvironment, rather only a single time point measurement of endothelium development. Therefore, nondestructive methods are needed to provide dynamic information of graft endothelialization and endothelium maturation in vitro. To address this need, we have developed a nondestructive fiber optic based (FOB imaging method that is capable of dynamic assessment of graft endothelialization without disturbing the graft housed in a bioreactor. In this study we demonstrate the capability of the FOB imaging method to quantify electrospun vascular graft endothelialization, EC detachment, and apoptosis in a nondestructive manner. The electrospun scaffold fiber diameter of the graft lumen was systematically varied and the FOB imaging system was used to noninvasively quantify the affect of topography on graft endothelialization over a 7-day period. Additionally, results demonstrated that the FOB imaging method had a greater imaging penetration depth than that of two-photon microscopy. This imaging method is a powerful tool to optimize vascular grafts and bioreactor conditions in vitro, and can be further adapted to monitor endothelium maturation and response to fluid flow bioreactor preconditioning.

  20. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Caregiver Support Caregiver Stories Home › What is Hepatic Encephalopathy? Why Your Liver is Important The Connection Between HE and Liver ... Why it’s Important to Treat HE Symptoms of Liver Failure Glossary of terms ... is Hepatic Encephalopathy? Hepatic Encephalopathy, sometimes referred to as portosystemic encephalopathy ...

  1. Effect of surface texture of grafted films on antithrombogenicity

    International Nuclear Information System (INIS)

    Otsuhata, K.; Razzak, M.T.; Castanares, R.L.; Tabata, Y.; Ohashi, F.; Takkeuchi, A.

    1985-01-01

    The relation between grafting conditions and antithrombogenicity has been examined from the purpose of clearing the necessity of controlling grafting conditions to enhance blood compatibility. The grafting systems employed here were N,N-dimethylacrylamide (DMAA) - poly(tetrafluoroethylene) (PTFE) and DMAA - poly(ethylene-co-tetrafluoroethylene) (AFLON) and grafting parameters were dose rate, monomer concentration and total dose (irradiation time). Grafting DMAA on to the substrates was carried out by using simultaneous irradiation method of gamma rays from a 60 Co source. After evaluation of blood compatibility of the grafted films by using in vitro tests, it has been clear that control of grafting conditions is important. Especially, in both grafting systems, dose rate control has found to be very important for blood compatibility. When higher dose rate of 1.0 x 10 5 to 3.0 x 10 5 rad/hr was used for grafting DMAA on to PTFE or AFLON, blood compatibility of the substrates was not enhanced, whereas it was improved when the grafting was carried out at lower dose rate of 0.97 x 10 4 rad/hr. The correlation between dose rate and antithrombogenicity has been interpreted in terms of surface-roughness of the grafted films. By scanning electron microscope (SEM) - observation, it has been observed that higher dose rate makes the surface rough, whereas lower dose rate makes it smooth. (author)

  2. Radiation-induced grafting of acrylic acid onto polyethylene filaments

    International Nuclear Information System (INIS)

    Kaji, K.; Sakurada, I.; Okada, T.

    1981-01-01

    Radiation-induced grafting of acrylic acid onto high density polyethylene (PE) filaments was carried out in order to raise softening temperature and impart flame retardance and hydrophilic properties. Mutual γ-irradiation method was employed for the grafting in a mixture of acrylic acid (AA), ethylene dichloride and water containing a small amount of ferrous ammonium sulfate. The rate of grafting was very low at room temperature. On the other hand, large percent grafts were obtained when the grafting was performed at an elevated temperature. Activation energy for the initial rate of grafting was found to be 17 kcal/mol between 20 and 60 0 C and 10 kcal/ mol between 60 and 80 0 C. Original PE filament begins to shrink at 70 0 C, shows maximum shrinkage of 50% at 130 0 C and then breaks off at 136 0 C. When a 34% AA graft is converted to metallic salt the graft filament retains its filament form even above 300 0 C and gives maximum shrinkage of 15%. Burning tests by a wire-netting basket method indicate that graft filaments and their metallic salts do not form melting drops upon burning and are self-extinguishing. Original PE filament shows no moisture absorption; however, that of AA-grafted PE increases with increasing graft percent. (author)

  3. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  4. Frenuloplasty with a splitthicknes skin graft

    International Nuclear Information System (INIS)

    Mohammadi, G.; Nnaderpour, M.

    2006-01-01

    The purpose of this study was to investigate the severity of presenting symptomatology in patients with ankyloglossia and to assess the surgical results of patients undergoing frenuloplasty with split thickness skin graft. During a 4 year period from September 1998 through September 2002, 19 patients of ankyloglosia underwent frenuloplasty with a split thickness skin graft. All skin grafts were taken from arm. There were 11 males and 8 females. The average length of the lingual frenulum was 3.5 mm. Twelve children were over 4 years old and were primarily operated with this technique. In the 7 patients, Z plasty had been performed previously but failed and cicatrisation caused ankyloglosia. There were two minor postoperative complications, one hematoma, and other graft dehiscence with cicatrisation. The mobility of the tongue after one year was excellent. There were no complications in donor site. Frenuloplasty with split thickness skin graft is the best and easy procedure with good results for children over 4 years and those who fail primary closure. (author)

  5. A comparison of the extended-release and standard-release formulations of tacrolimus in de novo kidney transplant recipients: a 12-month outcome study.

    Science.gov (United States)

    Fanous, Helen; Zheng, Rebecca; Campbell, Carolyn; Huang, Michael; Nash, Michelle M; Rapi, Lindita; Zaltzman, Jeffrey S; Prasad, G V Ramesh

    2013-02-01

    BACKGROUND: Limited comparative data are available on the outcomes between extended-release and standard-release tacrolimus when used de novo in kidney transplant recipients (KTRs). METHODS: We identified KTRs transplanted at our institution during 2009-10 routinely prescribed extended-release tacrolimus and compared them with those transplanted during 2008-09 prescribed standard-release tacrolimus. Graft function (eGFR by MDRD-7 equation) at 12 months post-transplant (primary outcome); new-onset diabetes and other cardiovascular risk factors, BK viremia incidence, acute rejection, and graft survival to 12 months (secondary outcomes) were compared by intent-to-treat analysis. Time-to-steady-state concentration and number of dose adjustments required to attain steady state were recorded. RESULTS: There were no important demographic differences between the extended-release (N = 106) and standard-release (N = 95) cohorts. The estimated glomerular filtration rate (eGFR) at 12 months was similar (58.8 ± 17 versus 59.2 ± 18 mL/min/1.73 m(2), P = 0.307). There was no difference in new-onset diabetes (17 versus 20%, P = 0.581), BK viremia (10 versus 7%, P = 0.450), acute rejection (7 versus 16%, P = 0.067) or graft survival (97 versus 95%, P = 0.301). Time-to-steady state was similar (9.2 ± 1.1 versus 8.1 ± 4.7 days, P = 0.490) although extended-release patients required fewer adjustments to attain steady state (1.2 ± 1.7 [0-8] versus 1.7 ± 1.5 [0-7], P = 0.030) but a similar dose (7.2 ± 2.4 [2-17] versus 7 ± 2.7 [2-16] mg/day, P = 0.697). CONCLUSION: De novo KTRs prescribed extended-release or standard-release tacrolimus demonstrate similar 12-month outcomes.

  6. More than a quarter of a century of liver transplantation in Kaohsiung Chang Gung Memorial Hospital.

    Science.gov (United States)

    Chen, Chao-Long; Concejero, Allan M; Cheng, Yu-Fan

    2011-01-01

    Liver transplantation has been an accepted treatment for end-stage liver disease since the 1980s. The development of living donor liver transplantation (LDLT) was driven by limited deceased donor organ donation and a response to the growing demand for the option of liver replacement. LDLT is now performed with high rates of success due to judicious donor and recipient selection, careful preoperative planning, excellent anesthesia management, and prompt detection and treatment of complications. The first successful liver transplantation in Asia was performed in 1984, in Chang Gung Memorial Hospital in a Taiwanese adolescent with Wilson's disease, complicated by end-stage liver cirrhosis. The longest Asian liver transplant survivor has now been living for 26 years and that patient's transplant was also performed in Chang Gung Memorial Hospital. Through December 31, 2011, a total of 924 (783 living donor, 141 deceased donor) liver transplants have been performed at the Kaohsiung Chang Gung Memorial Hospital, where both graft and patient survivals are excellent. For biliary atresia, hepatitis B virus cirrhosis, and hepatocellular carcinoma recipients, our 5-year LDLT survival rates are 98%, 94%, and 90%, respectively. Our overall (deceased and living donor) actuarial 3-year survival rate is 91%. Innovative techniques in LDLT represent technical refinements in hepatic vein, portal vein, hepatic artery, and biliary reconstruction approaches. Hepatic vein reconstruction is highlighted by venoplasty reconstructions in both graft hepatic vein orifices and recipient hepatic veins, to ensure adequate outflow and decrease ischemia times during implantation. Vascular interposition to reconstruct middle hepatic vein tributaries with either fresh or cryopreserved vessels is used when the middle hepatic vein is not routinely harvested with the graft. We have extended the routine use of microsurgical techniques, initially for hepatic artery reconstruction, to biliary reconstruction

  7. Local graft irradiation in renal transplant rejection

    International Nuclear Information System (INIS)

    Kawamura, Masashi; Kataoka, Masaaki; Itoh, Hisao

    1990-01-01

    From 1977 to 1988, of 142 renal transplantations, seven recipients (4.9%) received local graft irradiation following rejective reaction refractory to antirejection medical managements. Concurrent with the administration of pulsed high dose methylprednisolone and other antirejection medical managements, the graft was irradiated with a total dose of 6.0 Gy-150 cGy per fraction every other day at the midplane of the graft using two opposing portals of 4MX Linac. The fields were defined by palpation and echography. All patients had improvements in serum creatinine on the 10th day after beginning the irradiation. Four patients with peripheral lymphocytosis during the irradiation combined with pulsed high dose methylprednisolone improved in renal functions. On the other hand, out of 3 patients with lymphcytopenic changes, in two the transplanted graft was removed due to deteriorations, and the other patient is currently suffering from chronic rejection. Local graft irradiation can be useful in maintaining a rejective graft and reversing its functions in some patients whose rejective reaction failed to respond to the antirejection medical managements. (author)

  8. Cartilage grafting in nasal reconstruction.

    Science.gov (United States)

    Immerman, Sara; White, W Matthew; Constantinides, Minas

    2011-02-01

    Nasal reconstruction after resection for cutaneous malignancies poses a unique challenge to facial plastic surgeons. The nose, a unique 3-D structure, not only must remain functional but also be aesthetically pleasing to patients. A complete understanding of all the layers of the nose and knowledge of available cartilage grafting material is necessary. Autogenous material, namely septal, auricular, and costal cartilage, is the most favored material in a free cartilage graft or a composite cartilage graft. All types of material have advantages and disadvantages that should guide the most appropriate selection to maximize the functional and cosmetic outcomes for patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Graft copolimerization of hydrophilic monomers onto irradiated polypropylene fibers

    International Nuclear Information System (INIS)

    Sundardi, F.

    1978-01-01

    A method of graft copolymerization of hydrophilic monomers, such as 1-vinyl-2-pyrrolidone, acrylonitrile, acrylic acid, and acrylamide, onto irradiated polypropylene fibers has been studied. γ ray as well as electron beam were employed for the irradiation processes. Graft-copolymerization kinetics and the properties of grafted fibers have been investigated. Moisture regain, dyes absorption, and melting point of the grafted fibers were found to increase with the increasing of the degree of grafting. Polypropylene for 1-vinyl-2-pyrrolidone grafted fibers showed excellent dye absorption for almost all kinds of dyes such as direct, basic, acid, reactive, disper, and naphthol dyes. However, for polypropylene acrylic acid grafted fibers, the colorfastness to washing was found to be unsatisfactory. The colorfastness to washing for polypropylene 1-vinyl-2-pyrrolidone grafted fibers was found to be fairly good for certain types of dyes such as vat and naphthol dyes. (author)

  10. Fulminant Hepatic Failure Secondary to Primary Hepatic Angiosarcoma

    Directory of Open Access Journals (Sweden)

    Ayokunle T. Abegunde

    2015-01-01

    Full Text Available Background. Hepatic angiosarcoma is a rare and aggressive tumor that often presents at an advanced stage with nonspecific symptoms. Objective. To report a case of primary hepatic angiosarcoma in an otherwise healthy man with normal liver function tests two months prior to presenting with a short period of jaundice that progressed to fulminant hepatic failure. Methods. Case report and review of literature. Conclusion. This case illustrates the rapidity of progression to death after the onset of symptoms in a patient with hepatic angiosarcoma. Research on early diagnostic strategies and newer therapies are needed to improve prognosis in this rare and poorly understood malignancy with limited treatment options.

  11. Development of sodium alginate and konkoli gum- grafted ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-05-02

    May 2, 2008 ... grafted-polyacrylamide blend membrane: optimization of grafting conditions .... medium and reduce rate of termination by the coupling of the growing ... Effect of time. The time conversion curve of the graft copolymerization ...

  12. Absence of Middle Hepatic Vein Combined with Retro-Aortic Left Renal Vein: a Very Rare Case Report

    Directory of Open Access Journals (Sweden)

    Sezer Akçer

    2012-06-01

    Full Text Available The hepatic and renal veins drain into the inferior vena cava. The upper group of hepatic veins consists of three veins which extend to the posterior face of the liver to join the inferior cava. The left renal vein passes anterior to the aorta just below the origin of the superior mesenteric artery. We detected a variation in the hepatic and renal veins in a multislice CT angiogram of a nine-year-old male patient in the Radiology Department of Afyon Kocatepe University Medical School. The upper group hepatic veins normally drains into the inferior vena cava as three separate trunks, namely the right, left and middle. In our case, we found that only the right and left hepatic veins existed and the middle hepatic vein was absent. Furthermore, the left renal vein, which normally passes anterior to the abdominal aorta, was retro-aortic. Left renal vein variations are of great importance in planning retroperitoneal surgery and vascular interventions. Knowledge of a patient’s hepatic vein and renovascular anatomy and determining their variations and anomalies are of critical importance to abdominal operations, transplantations and preoperative evaluation of endovascular interventions.

  13. Transfusion-associated hepatitis before the screening of blood for hepatitis risk factors

    DEFF Research Database (Denmark)

    Engle, Ronald E; Bukh, Jens; Alter, Harvey J

    2014-01-01

    %) with HBV alone, and one (3%) with both viruses. Overall, 100% of patients with hepatitis and 39% of those without hepatitis were infected with HBV and/or HCV; one patient was also infected with hepatitis E virus. The donor carrier rate for HBV and/or HCV was estimated to be more than 6%; contemporaneously......%) developed biochemical evidence of hepatitis; of these, 20 (67%) were infected with hepatitis C virus (HCV) alone, four (13%) with hepatitis B virus (HBV) alone, and six (20%) with both viruses. Among the 36 patients who did not develop hepatitis, four (11%) were newly infected with HCV alone, nine (25...... prepared pooled normal human plasma was also contaminated with multiple hepatitis viruses. CONCLUSION: TAH virus infections were a larger problem than perceived 50 years ago and HCV was the predominant agent transmitted. All hepatitis cases could be attributed to HCV and/or HBV and hence...

  14. Antecedent thermal injury worsens split-thickness skin graft quality: A clinically relevant porcine model of full-thickness burn, excision and grafting.

    Science.gov (United States)

    Carlsson, Anders H; Rose, Lloyd F; Fletcher, John L; Wu, Jesse C; Leung, Kai P; Chan, Rodney K

    2017-02-01

    Current standard of care for full-thickness burn is excision followed by autologous split-thickness skin graft placement. Skin grafts are also frequently used to cover surgical wounds not amenable to linear closure. While all grafts have potential to contract, clinical observation suggests that antecedent thermal injury worsens contraction and impairs functional and aesthetic outcomes. This study evaluates the impact of antecedent full-thickness burn on split-thickness skin graft scar outcomes and the potential mediating factors. Full-thickness contact burns (100°C, 30s) were created on the backs of anesthetized female Yorkshire Pigs. After seven days, burn eschar was tangentially excised and covered with 12/1000th inch (300μm) split-thickness skin graft. For comparison, unburned wounds were created by sharp excision to fat before graft application. From 7 to 120days post-grafting, planimetric measurements, digital imaging and biopsies for histology, immunohistochemistry and gene expression were obtained. At 120days post-grafting, the Observer Scar Assessment Scale, colorimetry, contour analysis and optical graft height assessments were performed. Twenty-nine porcine wounds were analyzed. All measured metrics of clinical skin quality were significantly worse (pskin graft quality, likely by multiple mechanisms including burn-related inflammation, microscopically inadequate excision, and dysregulation of tissue remodeling. A valid, reliable, clinically relevant model of full-thickness burn, excision and skin replacement therapy has been demonstrated. Future research to enhance quality of skin replacement therapies should be directed toward modulation of inflammation and assessments for complete excision. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  15. [Viral hepatitis in travellers].

    Science.gov (United States)

    Abreu, Cândida

    2007-01-01

    Considering the geographical asymmetric distribution of viral hepatitis A, B and E, having a much higher prevalence in the less developed world, travellers from developed countries are exposed to a considerable and often underestimated risk of hepatitis infection. In fact a significant percentage of viral hepatitis occurring in developed countries is travel related. This results from globalization and increased mobility from tourism, international work, humanitarian and religious missions or other travel related activities. Several studies published in Europe and North America shown that more than 50% of reported cases of hepatitis A are travel related. On the other hand frequent outbreaks of hepatitis A and E in specific geographic areas raise the risk of infection in these restricted zones and that should be clearly identified. Selected aspects related with the distribution of hepatitis A, B and E are reviewed, particularly the situation in Portugal according to the published studies, as well as relevant clinical manifestations and differential diagnosis of viral hepatitis. Basic prevention rules considering enteric transmitted hepatitis (hepatitis A and hepatitis E) and parenteral transmitted (hepatitis B) are reviewed as well as hepatitis A and B immunoprophylaxis. Common clinical situations and daily practice "pre travel" advice issues are discussed according to WHO/CDC recommendations and the Portuguese National Vaccination Program. Implications from near future availability of a hepatitis E vaccine, a currently in phase 2 trial, are highlighted. Potential indications for travellers to endemic countries like India, Nepal and some regions of China, where up to 30% of sporadic cases of acute viral hepatitis are caused by hepatitis E virus, are considered. Continued epidemiological surveillance for viral hepatitis is essential to recognize and control possible outbreaks, but also to identify new viral hepatitis agents that may emerge as important global health

  16. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  17. Sodium and chloride exclusion and retention by non-grafted and grafted melon and Cucurbita plants

    Science.gov (United States)

    Edelstein, M.; Plaut, Z.; Ben-Hur, M.

    2011-01-01

    The effects of grafting on Na and Cl– uptake and distribution in plant tissues were quantified in a greenhouse experiment using six combinations of melon (Cucumis melo L. cv. Arava) and pumpkin (Cucurbita maxima Duchesne×Cucurbita moschata Duchesne cv. TZ-148): non-grafted, self-grafted, melons grafted on pumpkins, and pumpkins grafted on melons. Total Na concentration in shoots of plants with pumpkin or melon rootstocks was 400 mmol kg−1, respectively, regardless of the scion. In contrast, shoot Cl– concentrations were quite similar among the different scion–rootstock combinations. Na concentrations in exudates from cut stems of plants with a pumpkin rootstock were very low (<0.18 mM), whereas those in the exudates of plants with melon rootstocks ranged from 4.7 mM to 6.2 mM, and were quite similar to the Na concentration in the irrigation water. Root Na concentrations averaged 11.7 times those in the shoots of plants with pumpkin rootstocks, while in plants with melon rootstocks, values were similar. Two mechanisms could explain the decrease in shoot Na concentrations in plants with pumpkin rootstocks: (i) Na exclusion by the pumpkin roots; and (ii) Na retention and accumulation within the pumpkin rootstock. Quantitative analysis indicated that the pumpkin roots excluded ∼74% of available Na, while there was nearly no Na exclusion by melon roots. Na retention by the pumpkin rootstocks decreased its amount in the shoot by an average 46.9% compared with uniform Na distribution throughout the plant. In contrast, no retention of Na could be found in plants grafted on melons. PMID:20729482

  18. Sodium and chloride exclusion and retention by non-grafted and grafted melon and Cucurbita plants.

    Science.gov (United States)

    Edelstein, M; Plaut, Z; Ben-Hur, M

    2011-01-01

    The effects of grafting on Na and Cl(-) uptake and distribution in plant tissues were quantified in a greenhouse experiment using six combinations of melon (Cucumis melo L. cv. Arava) and pumpkin (Cucurbita maxima Duchesne×Cucurbita moschata Duchesne cv. TZ-148): non-grafted, self-grafted, melons grafted on pumpkins, and pumpkins grafted on melons. Total Na concentration in shoots of plants with pumpkin or melon rootstocks was 400 mmol kg(-1), respectively, regardless of the scion. In contrast, shoot Cl(-) concentrations were quite similar among the different scion-rootstock combinations. Na concentrations in exudates from cut stems of plants with a pumpkin rootstock were very low (<0.18 mM), whereas those in the exudates of plants with melon rootstocks ranged from 4.7 mM to 6.2 mM, and were quite similar to the Na concentration in the irrigation water. Root Na concentrations averaged 11.7 times those in the shoots of plants with pumpkin rootstocks, while in plants with melon rootstocks, values were similar. Two mechanisms could explain the decrease in shoot Na concentrations in plants with pumpkin rootstocks: (i) Na exclusion by the pumpkin roots; and (ii) Na retention and accumulation within the pumpkin rootstock. Quantitative analysis indicated that the pumpkin roots excluded ∼74% of available Na, while there was nearly no Na exclusion by melon roots. Na retention by the pumpkin rootstocks decreased its amount in the shoot by an average 46.9% compared with uniform Na distribution throughout the plant. In contrast, no retention of Na could be found in plants grafted on melons.

  19. Bone Graft Substitutes : Developed for Trauma and Orthopaedic Surgery

    NARCIS (Netherlands)

    J. van der Stok (Johan)

    2015-01-01

    markdownabstract__Abstract__ Bone grafting was established in the 19th century and has become a common procedure in which bone defects are filled with bone grafts or bone graft substitutes. Bone defects that require bone grafting are encountered in approximately 10% of trauma and orthopaedic

  20. Attitudes and Awareness Regarding Hepatitis B and Hepatitis C ...

    African Journals Online (AJOL)

    in many cases hepatitis B and C can lead to permanent liver ... Department of Public Health Dentistry, Gian Sagar Dental College and Hospital, 1Department of Oral Surgery, Gian ... training among HCWs to prevent the spread of hepatitis B virus and hepatitis C virus. ..... primary care physicians following the Department of.

  1. Pulmonary and intestinal permeabilities in alcoholic hepatic cirrhosis

    International Nuclear Information System (INIS)

    De Botton, S.; Huglo, B.; Canva-Delacambre, V.; Colombel, J.F.; Beauchat, V.; Ziegels, P.; Prangere, T.; Steinling, M.; Machandise, X.; Wallaert, B.

    1997-01-01

    The aim of this prospective study was to evaluate simultaneously the intestinal permeability (IP), usually normal, and the pulmonary permeability, (PP) rather rarely studied, in patients afflicted with hepatic cirrhosis of alcoholic (HCA) origin. Thirty five non-smoker patients, afflicted with HCA, proved by biopsy, without pulmonary pathology and with normal pulmonary scanography were subject to our investigation. The pre-graft hepatic examination contained also respiratory functional explorations as well as bronchi-alveolar clearance (BAC) explorations. After inhalation of the DTPA- 99m Tc aerosols, a 20 min dynamical study in posterior-front condition was achieved. After exponential matching on the activity/time curve of the right lung, the half life (T 1/2 in min) and the Residual Activity at 10 min (RA in %) were calculated. The PI were than estimated and on the basis of urinary activity of EDTA- 51 Cr obtained on 24 h and expressed in % of the uptake activity, according to the Bjarnasson's technique. The results were compared (significant non-parametric tests if p 1/2 and 87.1% ± 6.7 vs 92.8% ± 2.6 (p < 0.002) for RA. It is significantly correlated with the total number of cells (r = -0.379) and with the number of lymphocytes (r = 0.351) in the BAC. For the first time an enhanced PP was observed in HCA, correlated with the increase in the number of cells at BAC

  2. Application of Serum Hepatic Fibrosis Indices in the Diagnosis of Hepatic Disease

    International Nuclear Information System (INIS)

    Lu Yanting; Wang Taisong; Gu Xin

    2010-01-01

    To investigate the significance of combined detection of laminin (LN), collagen type IV (CIV), hyaluronic acid (HA) and precollagen type III (PCIII) in the diagnosis of hepatic fibrosis. The serum levels of LN, CIV, HA and PCIII in 143 patients with hepatic disease and 41 healthy controls were measured by radioimmunoassay (RIA). The results showed that the serum levels of LN, CIV, HA and PCIII in patients with hepatic disease were significantly higher than those of the control group (P<0.01), and the serum levels of those markers were related to the severity of the chronic hepatic disease. The highest serum levels were found in serious chronic hepatitis group and hepatic fibrosis group,and the increase of serum HA and PCIII was most remarkable. Combined detection of LN, CIV, HA and PCIII is a sensitive and reliable method in the diagnosis of hepatic fibrosis, but the four serum indices can not be used in differentiating serious chronic hepatitis and hepatic fibrosis. (authors)

  3. [Features of skin graft in pediatric plastic surgery].

    Science.gov (United States)

    Depoortère, C; François, C; Belkhou, A; Duquennoy-Martinot, V; Guerreschi, P

    2016-10-01

    Skin graft is a skin tissue fragment transferred from a donor site to a receiving site with a spontaneous revascularization. Basic process of plastic surgery, skin graft known in children, specific, warnings and refinements. It finds its indication in many pediatric cases: integumental diseases (neavus, hamartoma), acute burns and scars, traumatic loss of substance or surgically induced, congenital malformations of the hands and feet, etc. Specific skin graft techniques in children are developed: donor sites, sampling technique and procedure, early postoperative care. Especially in children, the scalp is a perfect site for split skin graft and technique is actively developed. Refinements and special cases are discussed: use of dermal matrices, allografts, xenografts, negative pressure therapy, prior skin expansion of the donor site. Results of skin graft in children are exposed: taking of graft, growth and shrinkage, pigmentation. Skin graft sometimes allows to stay the complex movement and get the best final benefit, permanent or at least temporary, in a growing being. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Improvement of the polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    2004-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect the ultimate performance of polymer products. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method photoprotector 2-hydroxy-4-(3-methacryloxy-2-hydroxy-propoxy) benzophenone has been readily grafted to low-density polyethylene in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of the stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. UV stability tests and changes in the mechanical properties of artificially and naturally aged films indicate pronounced protective effect achieved by the grafted stabilizer. Surface grafting is an efficient photostabilization method since the grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated

  5. Grafting of activated carbon cloths for selective adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Gineys, M.; Benoit, R.; Cohaut, N.; Béguin, F.; Delpeux-Ouldriane, S., E-mail: delpeux@cnrs-orleans.fr

    2016-05-01

    Graphical abstract: - Highlights: • A controlled grafting of carboxylic functions on activated carbon fibers. • The carbon material nanotextural properties preservation after grafting. • An identification of the grafting mechanism through ToF SIMS analysis. • A chemical mapping of the grafted surface using ToF SIMS technique and imaging. - Abstract: Chemical functionalization of an activated carbon cloth with 3-aminophthalic acid and 4-aminobenzoic acid groups by the in situ formation of the corresponding diazonium salt in aqueous acidic solution is reported. The nature and amount of selected functions on an activated carbon surface, in particular the grafted density, were determined by potentiometric titration, elemental analysis and X-ray photoelectron spectroscopy (XPS). The nanotextural properties of the modified carbon were explored by gas adsorption. Functionalized activated carbon cloth was obtained at a discrete grafting level while preserving interesting textural properties and a large porous volume. Finally, the grafting homogeneity of the carbon surface and the nature of the chemical bonding were investigated using Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) technique.

  6. Radiation-induced grafting of styrene on polypropylene pellets

    International Nuclear Information System (INIS)

    Souza, Camila P.; Ferreira, Henrique P.; Parra, Duclerc F.; Lugao, Ademar B.

    2009-01-01

    The changes of radiation-induced in polypropylene (PP) pellets exposed to gamma irradiation in inert atmosphere were investigated in correlation with the applied doses (10 and 50 kGy). Also, results from the grafting of styrene onto PP pellets using simultaneous irradiation at the same doses are presented. The grafting reaction was carried out using toluene as solvent, under nitrogen atmosphere and at room temperature. The properties of the irradiated and grafted PP pellets were studied using Melt Flow Index, thermal analysis (TG and DSC), and ATR-IR. The degree of grafting (DOG) for the grafted pellets was gravimetrically determined. The results showed that radiation-induced graft polymerization on pellets were successfully obtained and the influence of dose irradiated did not change the thermal properties in spite of the increase in the MFI and consequently this increase in the viscosity results an decrease the molecular mass. The MFI for grafted pellets was not achievable because the high degree of viscosity of polymer, even arising the test temperature, the polymer was not flow enough. (author)

  7. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  8. Pediatric liver transplantation using left hepatic segments from living related donors: surgical experience in 100 recipients at Saint-Luc University Clinics.

    Science.gov (United States)

    Darwish, Ahmed A; Bourdeaux, Christophe; Kader, Hesham A; Janssen, Magda; Sokal, Etienne; Lerut, Jan; Ciccarelli, Olga; Veyckemans, Francis; Otte, Jean-Bernard; de Goyet, Jean de Ville; Reding, Raymond

    2006-05-01

    Living-related liver transplantation was developed in the context of deceased donor organ shortage, which is particularly acute for pediatric recipients. This retrospective study analyzes the surgical technique and complications in the first 100 pediatric liver transplantation using left segmental liver grafts from living donors, performed at Saint-Luc University Clinics between July 1993 and April 2002. Pre-operative evaluation in donors and recipients, analysis of the surgical technique, and postoperative complications were reviewed. After a median follow-up period of 2526 days, no donor mortality was encountered, with a minimal morbidity and no long-term sequelae. At one and five yr post-transplantation, the actuarial patient survival rates were 94% and 92%, the corresponding figures being 92% and 89% for graft survival. The incidences of portal vein and hepatic artery thromboses, and of biliary complications were 14%, 1%, and 27%, respectively. Living-related liver transplantation in children constitutes an efficient therapy for liver failure to face the increased demand for liver grafts. Donor morbidity was kept to acceptable incidence, and surgical technique in the recipient needs to be tailored to minimize postoperative complications.

  9. Albumin grafting on polymer surfaces by gamma-irradiation

    International Nuclear Information System (INIS)

    Kamath, K.R.; Park, K.; DeMeo, D.

    1993-01-01

    Polymeric biomaterial surfaces were modified by albumin grafting to improve their blood compatibility. Albumin molecules were functionalized by introduction of double bonds. The functionalized albumin was covalently attached to polypropylene fibers, polycarbonate, and poly(vinyl chloride) by gamma-irradiation. ESCA and ATR/FTIR analysis of the control and grafted surfaces was conducted. Albumin grafting efficiency was found to be dependent on the gamma-irradiation time and the concentration of albumin as indicated by platelet adhesion studies. The grafted albumin molecules were not displaced when exposed to blood for prolonged time period. Finally, PLEXUS oxygenators grafted with albumin using this approach showed a significant reduction in platelet adhesion when compared to control

  10. ESR spectroscopic investigations of the radiation-grafting of fluoropolymers

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, G; Roduner, E [University of Stuttgart (Germany); Brack, H P; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    ESR spectroscopic investigations have clarified the influence of several preparative parameters on the reaction rates and yields obtained in the radiation-grafting method used at PSI to prepare proton-conducting polymer membranes. At a given irradiation dose, a higher concentration of reactive radical sites was detected in ETFE films than in FEP films. This higher concentration explains the higher grafting levels and rates of the ETFE films found in our previous grafting experiments. Taken together, the in-situ ESR experiments and grafting experiments show that the rates of disappearance of radical species and grafting rates and final grafting levels depend strongly on the reaction temperature and the oxygen content of the system. Average grafted chain lengths were calculated to contain about 1,000 monomer units. (author) 2 figs., 4 refs.

  11. Vascularised Fibular Graft for a Radial Defect following Tumour ...

    African Journals Online (AJOL)

    HP

    The mass was located on the radial aspect of the distal right ... modification, internal or external fixation with bone grafting, structural grafts of ... Our index case report demonstrates that free vascularized fibular graft transfer is a feasible option ... structural support, the potential for graft hypertrophy, relative resistance to ...

  12. Efficient visible light photocatalytic NO{sub x} removal with cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Xin [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Wendong [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Deng, Hua [State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Ni, Zilin [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Dong, Fan, E-mail: dfctbu@126.com [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Yuxin, E-mail: zhangyuxin@cqu.edu.cn [College of Materials Science and Engineering, National Key Laboratory of Fundamental Science of Micro/Nano-Devices and System Technology, Chongqing University, Chongqing 400044 (China)

    2017-01-15

    Graphical abstract: The cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures exhibits highly enhanced visible light photocatalytic air purification through an interfacial charge transfer process induced by Ag clusters. - Highlights: • Microstructural optimization and surface cluster-grafting were firstly combined. • Cationic Ag clusters were grafted on the surface of (BiO){sub 2}CO{sub 3} superstructures. • The Ag clusters-grafted BHS displayed enhanced visible light photocatalysis. • Direct interfacial charge transfer (IFCT) from BHS to Ag clusters was proposed. • The charge transfer process and the dominant reactive species were revealed. - Abstract: A facile method was developed to graft cationic Ag clusters on (BiO){sub 2}CO{sub 3} hierarchical superstructures (BHS) surface to improve their visible light activity. Significantly, the resultant Ag clusters-grafted BHS displayed a highly enhanced visible light photocatalytic performance for NOx removal due to the direct interfacial charge transfer (IFCT) from BHS to Ag clusters. The chemical and coordination state of the cationic Ag clusters was determined with the extended X-ray absorption fine structure (EXAFS) and a theoretical structure model was proposed for this unique Ag clusters. The charge transfer process and the dominant reactive species (·OH) were revealed on the basis of electron spin resonance (ESR) trapping. A new photocatalysis mechanism of Ag clusters-grafted BHS under visible light involving IFCT process was uncovered. In addition, the cationic Ag clusters-grafted BHS also demonstrated high photochemical and structural stability under repeated photocatalysis runs. The perspective of enhancing photocatalysis through combination of microstructural optimization and IFCT could provide a new avenue for the developing efficient visible light photocatalysts.

  13. The study on grafting comonomer of n-butyl acrylate and styrene onto poly(ethylene terephthalate) film by gamma-ray induced graft copolymerization

    Energy Technology Data Exchange (ETDEWEB)

    Ping Xiang; Wang Mozhen [CAS Key Laboratory of Soft Matter Chemistry, Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei, Anhui 230026 (China); Ge Xuewu, E-mail: xwge@ustc.edu.c [CAS Key Laboratory of Soft Matter Chemistry, Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2010-09-15

    Poly(ethylene terephthalate) (PET) film was successfully grafted with n-butyl acrylate and styrene comonomer through gamma-ray induced graft copolymerization. The degree of grafting (DG) and the composition of grafted side chain were characterized by {sup 1}H NMR. It was found that St can inhibit the homopolymerization of BA effectively and increase the DG when the concentration of comonomer mixture is kept constant. The proportion of St to BA in grafted side chain has a positive dependence on the feed ratio of St, which ultimately approaches the feed ratio. The thermal properties of poly(ethylene terephthalate)-graft-poly(n-butyl acrylate-co-styrene) (PET-g-P(BA-co-St)) films were investigated by differential scanning calorimetry (DSC) and dynamic mechanical thermal analysis (DMTA). The T{sub g} of PET decreases with the DG, indicating that the grafted P(BA-co-St) copolymer has good compatibility with PET backbone.

  14. Biofabrication and testing of a fully cellular nerve graft

    International Nuclear Information System (INIS)

    Owens, Christopher M; Marga, Francoise; Forgacs, Gabor; Heesch, Cheryl M

    2013-01-01

    Rupture of a nerve is a debilitating injury with devastating consequences for the individual's quality of life. The gold standard of repair is the use of an autologous graft to bridge the severed nerve ends. Such repair however involves risks due to secondary surgery at the donor site and may result in morbidity and infection. Thus the clinical approach to repair often involves non-cellular solutions, grafts composed of synthetic or natural materials. Here we report on a novel approach to biofabricate fully biological grafts composed exclusively of cells and cell secreted material. To reproducibly and reliably build such grafts of composite geometry we use bioprinting. We test our grafts in a rat sciatic nerve injury model for both motor and sensory function. In particular we compare the regenerative capacity of the biofabricated grafts with that of autologous grafts and grafts made of hollow collagen tubes by measuring the compound action potential (for motor function) and the change in mean arterial blood pressure as consequence of electrically eliciting the somatic pressor reflex. Our results provide evidence that bioprinting is a promising approach to nerve graft fabrication and as a consequence to nerve regeneration. (paper)

  15. Hepatitis A seroprevalence in patients with chronic viral hepatitis in Konya, Turkey.

    Science.gov (United States)

    Özden, Hale T

    2016-03-01

    Hepatitis A is among the diseases that can be prevented with vaccination in our time. Acute hepatitis A progresses more severely in individuals with a liver disease. Therefore, patients with a chronic liver disease (because of hepatitis B or hepatitis C) are advised vaccination with the hepatitis A vaccine. This study is aimed to determine the seroprevalence of hepatitis A virus (HAV) antibodies in patients infected with hepatitis C virus or hepatitis B virus in Konya province of Turkey. A total of 537 patients who had chronic viral hepatitis between January 2011 and December 2014 were included in the study. Serum samples were collected from each patient and tested for anti-HAV using the chemiluminescent microparticle immunoassay. The overall seroprevalence of total anti-HAV IgG was 94.2%. The overall prevalence of anti-HAV IgG in patients with chronic hepatitis B virus and hepatitis C virus infection was 97.5 and 93.6%, respectively. Anti-HAV IgG positivity was 97.4% in cirrhotic patients and 93.9% in noncirrhotic individuals. At the end of the study, being older than 40 years and living in a rural area were found to be independent risk factors for anti-HAV IgG seropositivity. In conclusion, we recommend that patients younger than 40 years and/or those living in cities and having a chronic liver disease should be vaccinated with the hepatitis A vaccine.

  16. Hepatitis A seroprevalence in patients with chronic viral hepatitis in Konya, Turkey

    Science.gov (United States)

    2016-01-01

    Aim Hepatitis A is among the diseases that can be prevented with vaccination in our time. Acute hepatitis A progresses more severely in individuals with a liver disease. Therefore, patients with a chronic liver disease (because of hepatitis B or hepatitis C) are advised vaccination with the hepatitis A vaccine. This study is aimed to determine the seroprevalence of hepatitis A virus (HAV) antibodies in patients infected with hepatitis C virus or hepatitis B virus in Konya province of Turkey. Methods A total of 537 patients who had chronic viral hepatitis between January 2011 and December 2014 were included in the study. Serum samples were collected from each patient and tested for anti-HAV using the chemiluminescent microparticle immunoassay. Results The overall seroprevalence of total anti-HAV IgG was 94.2%. The overall prevalence of anti-HAV IgG in patients with chronic hepatitis B virus and hepatitis C virus infection was 97.5 and 93.6%, respectively. Anti-HAV IgG positivity was 97.4% in cirrhotic patients and 93.9% in noncirrhotic individuals. Conclusion At the end of the study, being older than 40 years and living in a rural area were found to be independent risk factors for anti-HAV IgG seropositivity. In conclusion, we recommend that patients younger than 40 years and/or those living in cities and having a chronic liver disease should be vaccinated with the hepatitis A vaccine. PMID:26703930

  17. INFEKSI VIRUS HEPATITIS B DAN HEPATITIS C PADA PENDERITA HEPATITIS KRONIS DAN HEMODIALISIS DI JAKARTA

    Directory of Open Access Journals (Sweden)

    Djoko Yuwono

    2012-10-01

    Full Text Available Virus Hepatitis C dan Hepatitis B merupakan penyebab hepatitis kronik aktif yang dapat berkembang menjadi hepatoselular karsinoma. Untuk mengetahui peranan kedua jenis virus tersebut sebagai penyebab hepatoselular karsinoma, telah dilakukan pemeriksaan HbsAg, anti-VHC dan RNA-VHC pada 17 penderita hepatitis kronis. 19 Pasien hemodialisis dan 198 donor darah PMI. Pemeriksaan HbsAg dilakukan dengan RPHA Cell: pemeriksaan anti-VHC dengan dipstik anti-VHC kit diagnotik produksi NTB Mataram, Lombok. Deteksi RNA-VHC dilakukan dengan teknik RT-PCR, menggunakan primer spesifik untuk daerah 5'NCR. Hasil pemeriksaan menunjukkan bahwa pada penderita hepatitis kronis ditemukan 5 orang (23,5% positif HbsAg dan 1 orang (5,8% anti-VHC. Pada penderita hemodialisis ditemukan 14 orang (73,6% positif anti-VHC, persentase anti-VHC meningkat sesuai dengan meningkatnya frekuensi hemodialisis. Pada donor darah PMI ditemukan 5 orang (2,2% positif HbsAg dan tidak satupun ditemukan anti-VHC positif.

  18. Experimental study of CT perfusion in hepatitis, hepatic fibrosis and early stage of cirrhosis

    International Nuclear Information System (INIS)

    Guan Sheng; Zhao Weidong; Zhou Kangrong; Peng Weijun; Mao Jian; Tang Feng; Wang Yong; Cao Guang; Sun Fei

    2005-01-01

    Objective: To investigate the value of CT perfusion in the early diagnosis of hepatic diffuse disease. Methods: Fourteen male Wistar rats of control group and 14 of test group at stages of hepatitis, hepatic fibrosis, hepatic cirrhosis which were induced with diethylnitrosamine (DEN), were studied with CT perfusion respectively. CT perfusion data of different stages were compared and pathologic analysis were performed. Results: Density-time curves of CT perfusion were satisfactory and all perfusion data could be obtained. During the period of hepatitis developing into early stage of hepatic cirrhosis, hepatic artery flow (HAF) trended to increase in test group, mean transmit time (MTT) prolonged obviously, blood flow (BF) and volume (BV) declined. While in control group, HAF declined slightly, MTT, BV and BF increased. Statistic analysis showed the differences of HAF and MTT at different stages between control and test groups were significant (P<0.05 ); the differences of BV and BF between hepatitis and hepatic cirrhosis, hepatic fibrosis and early stage of hepatic cirrhosis in test group were significant (P<0.05), but no significant difference between hepatitis and hepatic fibrosis. The corresponding pathologic changes at stage of hepatitis was swelling of hepatic cells; sinusoids cap illarization and deposition of collagen in the extravascular Disse's spaces were the main changes relating to hepatic blood perfusion at stage of fibrosis and early stage of cirrhosis. Conclusion: The method of CT scan can reflect some changes of hepatic blood perfusion in rats with hepatitis, hepatic fibrosis and early stage of cirrhosis. The data of CT perfusion, especially the changes should be valuable for clinical early diagnosis, treatment and follow-up. (authors)

  19. Defibrotide for the Treatment of Hepatic Veno-Occlusive Disease: Final Results From the International Compassionate-Use Program.

    Science.gov (United States)

    Corbacioglu, Selim; Carreras, Enric; Mohty, Mohamad; Pagliuca, Antonio; Boelens, Jaap Jan; Damaj, Gandhi; Iacobelli, Massimo; Niederwieser, Dietger; Olavarría, Eduardo; Suarez, Felipe; Ruutu, Tapani; Verdonck, Leo; Hume, Robin; Nejadnik, Bijan; Lai, Chinglin; Finetto, Giorgia; Richardson, Paul

    2016-10-01

    Hepatic veno-occlusive disease, also called sinusoidal obstruction syndrome (VOD/SOS), is an unpredictable and potentially fatal complication of hematopoietic cell transplantation (HCT) or nontransplantation-associated chemotherapy/radiotherapy. In cases of severe hepatic VOD/SOS, typically defined by associated multiorgan failure (MOF, also known as multiorgan dysfunction), mortality exceeds 80%. Preclinical and early clinical data have provided a rationale for defibrotide treatment in hepatic VOD/SOS. Based on this evidence and in recognition of the dismal prognosis for these patients, defibrotide was made available through an international multicenter compassionate-use program conducted from December 1998 to March 2009. Physicians participating in the program voluntarily provided demographic and outcome data for patients given defibrotide. Efficacy and safety analyses were performed using the data received for 710 treated patients. Defibrotide was given at 10, 25, 40, 60, or 80 mg/kg/day for a median of 15 days (range, 1 to 119 days). By Kaplan-Meier analysis, the estimated overall day +100 survival was 54% (58% in the 25 mg/kg/day dose group). Adverse events (AEs) were reported in 53% of patients. The most common AEs were MOF, progression of hepatic VOD/SOS, sepsis, and graft-versus-host disease, which were consistent with the AEs expected for this patient population. No clinically meaningful trends in AEs were identified by gender, age, or dose group. Safety and efficacy resultswere consistent with prior studies of defibrotide in hepatic VOD/SOS, and subgroup analyses lend support to the use of the 25 mg/kg/day dose. Copyright © 2016 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Hepatitis Risk Assessment

    Science.gov (United States)

    ... please visit this page: About CDC.gov . Hepatitis Risk Assessment Recommend on Facebook Tweet Share Compartir Viral Hepatitis. Are you at risk? Take this 5 minute Hepatitis Risk Assessment developed ...

  1. Yeast-recombinant hepatitis B vaccine: efficacy with hepatitis B immune globulin in prevention of perinatal hepatitis B virus transmission

    International Nuclear Information System (INIS)

    Stevens, C.E.; Taylor, P.E.; Tong, M.J.; Toy, P.T.; Vyas, G.N.; Nair, P.V.; Weissman, J.Y.; Krugman, S.

    1987-01-01

    A yeast-recombinant hepatitis B vaccine was licensed recently by the Food and Drug administration and is now available. To assess the efficacy of the yeast-recombinant vaccine, the authors administered the vaccine in combination with hepatitis B immune globulin to high-risk newborns. If infants whose mothers were positive for both hepatitis B surface antigen and the e antigen receive no immunoprophylaxis, 70% to 90% become infected with the virus, and almost all become chronic carriers. Among infants in this study who received hepatitis B immune globulin at birth and three 5- + g doses of yeast-recombinant hepatitis B vaccine, only 4.8% became chronic carriers, a better than 90% level of protection and a rate that is comparable with that seen with immune globulin and plasma-derived hepatitis B vaccine. Hepatitis surface antigen and antibodies were detected by radioimmunoassay. These data suggest that, in this high-risk setting, the yeast-recombinant vaccine is as effective as the plasma-derived vaccine in preventing hepatitis B virus infection and the chronic carrier state

  2. Hepatitis C Virus E2 Envelope Glycoprotein Core Structure

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Leopold; Giang, Erick; Nieusma, Travis; Kadam, Rameshwar U.; Cogburn, Kristin E.; Hua, Yuanzi; Dai, Xiaoping; Stanfield, Robyn L.; Burton, Dennis R.; Ward, Andrew B.; Wilson, Ian A.; Law, Mansun

    2014-08-26

    Hepatitis C virus (HCV), a Hepacivirus, is a major cause of viral hepatitis, liver cirrhosis, and hepatocellular carcinoma. HCV envelope glycoproteins E1 and E2 mediate fusion and entry into host cells and are the primary targets of the humoral immune response. The crystal structure of the E2 core bound to broadly neutralizing antibody AR3C at 2.65 angstroms reveals a compact architecture composed of a central immunoglobulin-fold β sandwich flanked by two additional protein layers. The CD81 receptor binding site was identified by electron microscopy and site-directed mutagenesis and overlaps with the AR3C epitope. The x-ray and electron microscopy E2 structures differ markedly from predictions of an extended, three-domain, class II fusion protein fold and therefore provide valuable information for HCV drug and vaccine design.

  3. Photoacoustic detection of neovascularities in skin graft

    Science.gov (United States)

    Yamazaki, Mutsuo; Sato, Shunichi; Saitoh, Daizo; Ishihara, Miya; Okada, Yoshiaki; Ashida, Hiroshi; Obara, Minoru

    2005-04-01

    We previously proposed a new method for monitoring adhesion of skin graft by measuring photoacoustic (PA) signal originated from the neovascularities. In this study, immunohistochemical staining (IHC) with CD31 antibody was performed for grafted skin tissue to observe neovascularity, and the results were compared with PA signals. We also used a laser Doppler imaging (LDI) to observe blood flow in the grafted skin, and sensitivity of PA measurement and that of LDI were compared. In rat autograft models, PA signals were measured for the grafted skin at postgrafting times of 0-48 h. At 6 h postgrafting, PA signal was observed in the skin depth region of 500-600 mm, while the results of IHC showed that angiogenesis occurred at the depth of about 600 mm. Depths at which PA signal and angiogenesis were observed decreased with postgrafting time. These indicate that the PA signal observed at 6 h postgrafting originated from the neovascularities in the skin graft. Results of LDI showed no blood-originated signal before 48 h postgrafting. These findings suggest that PA measurement is effective in monitoring the adhesion of skin graft in early stage after transplantation.

  4. Nonalcoholic fatty liver disease and hepatic cirrhosis: Comparison with viral hepatitis-associated steatosis.

    Science.gov (United States)

    Haga, Yuki; Kanda, Tatsuo; Sasaki, Reina; Nakamura, Masato; Nakamoto, Shingo; Yokosuka, Osamu

    2015-12-14

    Nonalcoholic fatty liver disease (NAFLD) including nonalcoholic steatohepatitis (NASH) is globally increasing and has become a world-wide health problem. Chronic infection with hepatitis B virus or hepatitis C virus (HCV) is associated with hepatic steatosis. Viral hepatitis-associated hepatic steatosis is often caused by metabolic syndrome including obesity, type 2 diabetes mellitus and/or dyslipidemia. It has been reported that HCV genotype 3 exerts direct metabolic effects that lead to hepatic steatosis. In this review, the differences between NAFLD/NASH and viral hepatitis-associated steatosis are discussed.

  5. Quantifying Long-term Retention of Excised Fat Grafts

    DEFF Research Database (Denmark)

    Herly, Mikkel; Ørholt, Mathias; Glovinski, Peter V.

    2017-01-01

    Background: Predicting the degree of fat graft retention is essential whenplanning reconstruction or augmentation with free fat grafting. Most surgeonsobserve volume loss over time after fat grafting; however, the portion lost toresorption after surgery is still poorly defined, and the time to re...

  6. Radiation grafting of dimethylaminopropylacrylamide and dimethylaminopropylmethacrylamide onto polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Burillo, Guillermina; Oseguera, M.A. [UNAM, Inst. de Ciencias Nucleares, Mexico City (Mexico); Vazquez, Carmen; Castillo, L.P. del [UNAM, Inst. de Investigaciones en Materiales, Mexico City (Mexico)

    1997-11-01

    Radiation-induced grafting of dimethylaminopropylacrylamide and dimethylamino-propylmethacrylamide onto polyethylene films, by direct grafting of the vinyl monomers to a polymer by mutual irradiation, has been investigated. The kinetics of the reaction were studied at different irradiation temperatures, monomer concentration and dose rates of gamma rays, and the appropriate reaction conditions for graft polymerization were determined. The thermal and mechanical behavior of the grafted films by means of DMA, TMA, DSC and TGA were also investigated. (author).

  7. Oral mucosa grafts for urethral reconstruction

    African Journals Online (AJOL)

    reports reveal that split and full thickness skin grafts from the scrotum, penis, extragenital sites (ureter, saphenous .... Table 1: Summary of the history of oral mucosa grafts for urethroplasty .... advised that care should be taken when suturing the.

  8. Liver Cancer and Hepatitis B

    Science.gov (United States)

    ... Clinical Trials Physician Directory HBV Meeting What Is Hepatitis B? What Is Hepatitis B? The ABCs of Viral Hepatitis Liver Cancer and Hepatitis B Hepatitis Delta Coinfection Hepatitis C Coinfection HIV/AIDS ...

  9. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  10. Long-term results of PTFE grafts.

    Science.gov (United States)

    Hedin, Ulf

    2015-01-01

    Vascular surgeons are essential in "lifeline" creation for hemodialysis patients and should be the central player in any multidisciplinary access service together with nephrologists, dialysis staff and interventional radiology. In this position, access surgeons are involved in complicated clinical decision making regarding primary and secondary access selection, which throughout the last decade has been largely aided, and influenced, by national and international guidelines as well as other initiatives. These recommendations, unanimously and appropriately, advocate the placement of native fistulas over synthetic grafts (the majority grafts from expanded polytetrafluoroethylene, ePTFE, herein referred to as PTFE) based on the superiority of fistulas with respect to complications such as infections and thrombosis. Nevertheless, the use of PTFE grafts for hemodialysis access is an accepted and firmly established alternative to native fistulas where data today reveal unwanted consequences to overinterpretation of established guidelines such as increased catheter use. This information highlights a need for an adjustment of access selection strategies based on patient-centered algorithms. Here, available results on PTFE graft performance in hemodialysis access is recapitulated, with respect to both conventional grafts and technical modifications, and conclude with a modified approach to primary access selection.

  11. The autologus graft of epithelial tissue culture

    Directory of Open Access Journals (Sweden)

    Minaee B

    1999-08-01

    Full Text Available With the intention of research about culture and autologus graft of epithelial tissue we used 4 french Albino Rabbits with an average age of 2 months. After reproduction on the support in EMEM (Eagle's Minimum Essential Medium we used this for graft after 4 weeks. This region which grafted total replaced. After fixation of this sample and passing them through various process, histological sections were prepared. These sections were stained with H & E and masson's trichrome and studied by light microscope. We succeeded in graft. We hope in the near future by using the method of epithelium tissue culture improving to treat burned patients.

  12. Extended Distal Pancreatectomy with En Bloc Resection of the Celiac Axis for Locally Advanced Pancreatic Cancer: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Patrick H. Alizai

    2012-01-01

    Full Text Available Due to a lack of early symptoms, pancreatic cancers of the body and tail are discovered mostly at advanced stages. These locally advanced cancers often involve the celiac axis or the common hepatic artery and are therefore declared unresectable. The extended distal pancreatectomy with en bloc resection of the celiac artery may offer a chance of complete resection. We present the case of a 48-year-old female with pancreatic body cancer invading the celiac axis. The patient underwent laparoscopy to exclude hepatic and peritoneal metastasis. Subsequently, a selective embolization of the common hepatic artery was performed to enlarge arterial flow to the hepatobiliary system and the stomach via the pancreatoduodenal arcades from the superior mesenteric artery. Fifteen days after embolization, the extended distal pancreatectomy with splenectomy and en bloc resection of the celiac axis was carried out. The postoperative course was uneventful, and complete tumor resection was achieved. This case report and a review of the literature show the feasibility and safety of the extended distal pancreatectomy with en bloc resection of the celiac axis. A preoperative embolization of the celiac axis may avoid ischemia-related complications of the stomach or the liver.

  13. Hepatitis B & C and HIV

    Science.gov (United States)

    ... Find Services HIV SERVICES LOCATOR Locator Search Search Hepatitis B & C Topics Hepatitis B Hepatitis C Hepatitis ... Infections Sexually Transmitted Diseases Smoking Women's Health Issues Hepatitis B Virus and Hepatitis C Virus Infection People ...

  14. Acrylique acid grafted polyolefines. Thermoadhesive applications

    International Nuclear Information System (INIS)

    Guimon, Claude

    1979-01-01

    Radiochemical grafting of polyolefines by peroxidation has been industrialized in France for about 10 years by irradiation of these polymers with an electron accelerator and then treated by acrylic acid. Products obtained show a high adhesivity on metallic surfaces above their melting point. The main application of acrylic acid grafted high density polyethylene is composite film with aluminum foil for thermosealing of plastic bottle caps of sterilized milk. Acrylic acid grafted polypropylene is used in suspension in a volatile liquid for aluminum foil coating satisfying food packaging regulations [fr

  15. Study on radiation grafting of acrylic acid onto fluorine-containing polymers. II. Properties of membrane obtained by preirradiation grafting onto poly(tetrafluoroethylene)

    International Nuclear Information System (INIS)

    Hegazy, E.S.A.; Ishigaki, I.; Rabie, A.; Dessouki, A.M.; Okamoto, J.

    1981-01-01

    Some properties of the membranes obtained by the preirradiation grafting of acrylic acid onto poly(tetrafluoroethylene) (PTFE) film have been studied. The dimensional change by grafting and swelling, water uptake, electric conductivity, and mechanical properties of the grafted PTFE films were measured and were found to increase as the grafting proceeds. These properties were found to be dependent mainly on the degree of grafting regardless of grafting conditions except higher monomer concentration (80 wt %). The electric conductivity and mechanical properties of the membranes at 80 wt % monomer concentration is lower than those at a lower monomer concentration. The results suggest that the membranes obtained at 80-wt % acrylic acid solution have a somewhat heterogeneous distribution of electrolyte groups as compared with those prepared at a monomer concentration less than 60 wt %. X-ray microscopy of the grafted films revealed that the grafting begins at the part close to the film surface and proceeds into the center with progressive diffusion of monomer to give finally the homogeneous distribution of electrolyte groups. The membranes show good electrochemical and mechanical properties which make them acceptable for the practical uses as cation exchange membrane

  16. Hepatitis C: Sex and Sexuality

    Science.gov (United States)

    ... with Hepatitis » Sex and Sexuality: Entire Lesson Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... hepatitis C virus through sex. Can you pass hepatitis C to a sex partner? Yes, but it ...

  17. Hepatitis C: Diet and Nutrition

    Science.gov (United States)

    ... with Hepatitis » Daily Living: Diet and Nutrition Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... have high cholesterol and have fatty liver. How hepatitis C affects diet If you have hepatitis, you ...

  18. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    Science.gov (United States)

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  19. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  20. Experiences with surgically treated primary or secondary hepatic sarcoma.

    Science.gov (United States)

    Fahrner, René; Dennler, Sandra G C; Dondorf, Felix; Ardelt, Michael; Rauchfuss, Falk; Settmacher, Utz

    2017-06-01

    Liver resection in hepatic sarcoma is rare, but other alternative treatment options are scarce. Surgery offers the only aggressive approach to achieve a tumour-free state. The aim of this investigation was to evaluate the outcome and survival of these patients at a single hepato-biliary university hospital. Between January 2004 and July 2013, 896 anatomical liver resections were performed. Eleven liver resections (1.2%) were performed due to primary hepatic sarcoma or hepatic sarcoma metastases. The demographic and clinical parameters were collected from the institutional patients' records. In eight patients (83%), liver resection was performed due to hepatic sarcoma metastases. The surgical procedures were as follows: two patients (18%) had segmentectomy, six patients (55%) had hemihepatectomy or extended hemihepatectomy and three patients (27%) had multivisceral resections. In nine patients (82%), the resection margins were tumour free. In 55% (n = 6) of the patients, the maximal tumour diameter was greater than 10 cm. The postoperative morbidity was low with a Clavien-Dindo score of 2 (range 0-5). One patient died on postoperative day 2 after multivisceral resection. During the follow-up of 932 days (range 2-2.220 days) the 1-, 2- and 3-year survival rates were 91, 63 and 45%, respectively. Tumour recurrence was detected in seven patients (63%). Liver resections in patients with primary or secondary hepatic sarcoma are rare. The main goal in these patients is to achieve complete tumour resection because chemotherapy offers no suitable alternative, but the long-term survival rates are limited because of high a recurrence rate even after aggressive surgical approaches.

  1. Genome-wide identification and comparative analysis of grafting-responsive mRNA in watermelon grafted onto bottle gourd and squash rootstocks by high-throughput sequencing.

    Science.gov (United States)

    Liu, Na; Yang, Jinghua; Fu, Xinxing; Zhang, Li; Tang, Kai; Guy, Kateta Malangisha; Hu, Zhongyuan; Guo, Shaogui; Xu, Yong; Zhang, Mingfang

    2016-04-01

    Grafting is an important agricultural technique widely used to improve plant growth, yield, and adaptation to either biotic or abiotic stresses. However, the molecular mechanisms underlying grafting-induced physiological processes remain unclear. Watermelon (Citrullus lanatus L.) is an important horticultural crop worldwide. Grafting technique is commonly used in watermelon production for improving its tolerance to stresses, especially to the soil-borne fusarium wilt disease. In the present study, we used high-throughput sequencing to perform a genome-wide transcript analysis of scions from watermelon grafted onto bottle gourd and squash rootstocks. Our transcriptome and digital gene expression (DGE) profiling data provided insights into the molecular aspects of gene regulation in grafted watermelon. Compared with self-grafted watermelon, there were 787 and 3485 genes differentially expressed in watermelon grafted onto bottle gourd and squash rootstocks, respectively. These genes were associated with primary and secondary metabolism, hormone signaling, transcription factors, transporters, and response to stimuli. Grafting led to changes in expression of these genes, suggesting that they may play important roles in mediating the physiological processes of grafted seedlings. The potential roles of the grafting-responsive mRNAs in diverse biological and metabolic processes were discussed. Obviously, the data obtained in this study provide an excellent resource for unraveling the mechanisms of candidate genes function in diverse biological processes and in environmental adaptation in a graft system.

  2. Intraarterial 9-beta-methyl carbacyclin improves canine polytetrafluoroethylene graft patency

    International Nuclear Information System (INIS)

    Dacey, L.J.; Hees, P.S.; Cronenwett, J.L.

    1988-01-01

    This study examined the effect of 9-beta-methyl carbacyclin, a synthetic, stable prostacyclin analog, on canine polytetrafluoroethylene (PTFE) graft patency. Twenty-five dogs had 4 mm x 7 cm PTFE grafts implanted bilaterally into the femoral arteries. A subcutaneous infusion pump was used to deliver either saline solution (control) or 9-beta-methyl carbacyclin (Ciprostine) at 100 (CARB-100) or 200 ng/kg/min (CARB-200) through a femoral artery branch just proximal to one of the femoral grafts, with the contralateral graft serving as a noninfused control. Graft-platelet deposition (with 111 In-labeled platelets) was measured between the fifth and seventh days, with patency determined on the seventh day. Dogs were classified as aggregators (AGG [+]) if the preoperative epinephrine-enhanced sodium arachidonate platelet aggregation was greater than 20%. CARB-200 infusion significantly improved ipsilateral graft patency (80%) compared with noninfused grafts (50%, p less than 0.05), or grafts in control and CARB-100 dogs (43%, p less than 0.05). Anastomotic platelet deposition was decreased bilaterally in CARB-200 dogs by 45% to 59% compared with CARB-100 and control dogs (p less than 0.05). With the exception of grafts infused with CARB-200, AGG (+) dogs had significantly lower graft patency (26%) than nonaggregator AGG (-) dogs (71%, p less than 0.01). CARB-200 infusion significantly improved graft patency in AGG (+) dogs (71%), compared with control and CARB-100-infused grafts (19%, p less than 0.025). Intra-arterial 9-beta-methyl carbacyclin improved early PTFE graft patency and inhibited platelet deposition in a severe canine model, independent of baseline platelet aggregation status, which also had an important effect on graft patency

  3. Does chronic hepatitis B infection affect the clinical course of acute hepatitis A?

    Science.gov (United States)

    Shin, Su Rin; Moh, In Ho; Jung, Sung Won; Kim, Jin Bae; Park, Sang Hoon; Kim, Hyoung Su; Jang, Myung Kuk; Lee, Myung Seok

    2013-01-01

    The impact of chronic hepatitis B on the clinical outcome of acute hepatitis A remains controversial. The aim of present study was to evaluate the clinical characteristics of acute hepatitis A in cases with underlying chronic hepatitis B compared to cases of acute hepatitis A alone. Data on 758 patients with acute hepatitis A admitted at two university-affiliated hospitals were reviewed. Patients were classified into three groups: group A, patients with both acute hepatitis A and underlying chronic hepatitis B (n = 27); group B, patients infected by acute hepatitis A alone whose sexes and ages were matched with patients in group A (n  = 54); and group C, patients with acute hepatitis A alone (n = 731). None of the demographic features of group A were significantly different from those of group B or C, except for the proportion of males and body weight, which differed from group C. When comparing to group B, clinical symptoms were more frequent, and higher total bilirubin and lower albumin levels were observed in group A. When comparing to group C, the albumin levels were lower in group A. There were no differences in the duration of hospital stay, occurrence of acute kidney injury, acute liver failure, prolonged cholestasis, or relapsing hepatitis. This study revealed that clinical symptoms and laboratory findings were less favorable for patients with acute hepatitis A and chronic hepatitis B compared to those with acute hepatitis A alone. However, there were no differences in fatal outcomes or serious complications. Copyright © 2012 Wiley Periodicals, Inc.

  4. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  5. A Review on Grafting of Biofibers for Biocomposites.

    Science.gov (United States)

    Wei, Liqing; McDonald, Armando G

    2016-04-22

    A recent increase in the use of biofibers as low-cost and renewable reinforcement for the polymer biocomposites has been seen globally. Biofibers are classified into: lignocellulosic fibers ( i.e. , cellulose, wood and natural fibers), nanocellulose ( i.e. , cellulose nanocrystals and cellulose nanofibrils), and bacterial cellulose, while polymer matrix materials can be petroleum based or bio-based. Green biocomposites can be produced using both biobased fibers and polymers. Incompatibility between the hydrophilic biofibers and hydrophobic polymer matrix can cause performance failure of resulting biocomposites. Diverse efforts have focused on the modification of biofibers in order to improve the performances of biocomposites. "Grafting" copolymerization strategy can render the advantages of biofiber and impart polymer properties onto it and the performance of biocomposites can be tuned through changing grafting parameters. This review presents a short overview of various "grafting" methods which can be directly or potentially employed to enhance the interaction between biofibers and a polymer matrix for biocomposites. Major grafting techniques, including ring opening polymerization, grafting via coupling agent and free radical induced grafting, have been discussed. Improved properties such as mechanical, thermal, and water resistance have provided grafted biocomposites with new opportunities for applications in specific industries.

  6. Morphological observation, RNA-Seq quantification, and expression profiling: novel insight into grafting-responsive carotenoid biosynthesis in watermelon grafted onto pumpkin rootstock.

    Science.gov (United States)

    Liu, Guang; Yang, Xingping; Xu, Jinhua; Zhang, Man; Hou, Qian; Zhu, Lingli; Huang, Ying; Xiong, Aisheng

    2017-03-01

    Watermelon is an important and economical horticultural crop in China, where ~20% of the plants are grafted. The development of grafted watermelon fruit involves a diverse range of gene interactions that results in dynamic changes in fruit. However, the molecular mechanisms underlying grafting-induced fruit quality change are unclear. In the present study, we measured the lycopene content by high-performance liquid chromatography and used RNA-Seq (quantification) to perform a genome-wide transcript analysis of fruits from watermelon grafted onto pumpkin rootstock (pumpkin-grafted watermelon, PGW), self-grafted watermelon (SGW), and non-grafted watermelon (NGW). The results showed variation in the lycopene content in the flesh of PGW fruits, first increasing and then decreasing in the four stages, which was different from the trend in the flesh of NGW and SGW fruits. The transcriptome profiling data provided new information on the grafting-induced gene regulation of lycopene biosynthesis during fruit growth and development. The expression levels of 33 genes from 8 gene families (GGPS, PSY, PDS, ZDS, CRTISO, LCYb, LCYe, and CHY) related to lycopene biosynthesis, which play critical roles in fruit coloration and contribute significantly to fruit phytonutrient values, were monitored during the four periods of fruit development in watermelon. Compared with those of NGW and SGW, 14 genes were differentially expressed in PGW during fruit development, suggesting that these genes possibly help to mediate lycopene biosynthesis in grafted watermelon fruit. Our work provides some novel insights into grafting-responsive carotenoid metabolism and its potential roles during PGW fruit development and ripening. © The Author 2016. Published by Oxford University Press on behalf of the Institute of Biochemistry and Cell Biology, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Sulfonated hydrocarbon graft architectures for cation exchange membranes

    DEFF Research Database (Denmark)

    Nielsen, Mads Møller; Jankova Atanasova, Katja; Hvilsted, Søren

    2013-01-01

    A synthetic strategy to hydrocarbon graft architectures prepared from a commercial polysulfone and aimed as ion exchange membrane material is proposed. Polystyrene is grafted from a polysulfone macroinitiator by atom transfer radical polymerization, and subsequently sulfonated with acetyl sulfate...... to various degrees. Series of grafting densities and graft lengths are prepared, and membranes are solvent cast from DMSO. The membrane properties in aqueous environments are evaluated from their water swelling behavior, and their thermal properties and stability are investigated by thermogravimetric...

  8. History of free skin grafting. Knowledge of empiricism?

    OpenAIRE

    Klasen, Hendrik Jan

    1981-01-01

    In the course of more than a hundred years, skin grafting has become a standard procedure in surgery. The indications for the several types of grafting have become rather uniform.The technical aids at the operations only differ in details. Especially the vast experience gained in World War II provided the opportunity to develop the technique of skin grafting and so the evolution of present day plastics surgery. However, virtually every step in the field of indications, selection of grafts, te...

  9. Hot callusing for propagation of American beech by grafting

    Science.gov (United States)

    David W. Carey; Mary E. Mason; Paul Bloese; Jennifer L. Koch

    2013-01-01

    To increase grafting success rate, a hot callus grafting system was designed and implemented as part of a multiagency collaborative project to manage beech bark disease (BBD) through the establishment of regional BBD-resistant grafted seed orchards. Five years of data from over 2000 hot callus graft attempts were analyzed using a logistic regression model to determine...

  10. How Hepatitis D Virus Can Hinder the Control of Hepatitis B Virus

    NARCIS (Netherlands)

    Xiridiou, M.; Borkent-Raven, B.; Hulshof, J.; Wallinga, J.

    2009-01-01

    Background: Hepatitis D (or hepatitis delta) virus is a defective virus that relies on hepatitis B virus (HBV) for transmission; infection with hepatitis D can occur only as coinfection with HBV or superinfection of an existing HBV infection. Because of the bond between the two viruses, control

  11. Microbiological diagnostics of viral hepatitis

    OpenAIRE

    HASDEMİR, Ufuk

    2016-01-01

    Viral hepatitis is an infection that primarily affects the liverbut may also have systemic clinical manifestations. The vastmajority of viral hepatitis are caused by one of five hepatotropicviruses: hepatitis A virus (HAV), hepatitis B virus (HBV),hepatitis C virus (HCV), hepatitis D (delta) virus (HDV), andhepatitis E virus (HEV) (Table I) [1]. HBV, HCV, and HDValso cause chronic hepatitis, whereas HAV does not. HEVcauses acute hepatitis in normal hosts but can cause protractedand chronic he...

  12. SOME TECHNIQUES IN CORNEAL GRAFTING

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... current herpes corneae. The visual acuity was less than. 6/60. The left eye had had a central nebula since child- hood and was deemed amblyopic. Six weeks after a 7 x 0·3 mm lamellar graft in the right eye was placed, ulceration occurred in the graft junction. A total thin conjunctival flap was sutured over.

  13. Postoperative Insulin-Like Growth Factor 1 Levels Reflect the Graft's Function and Predict Survival after Liver Transplantation.

    Directory of Open Access Journals (Sweden)

    Daniele Nicolini

    Full Text Available The reduction of insulin-like growth factor 1 (IGF-1 plasma levels is associated with the degree of liver dysfunction and mortality in cirrhotic patients. However, little research is available on the recovery of the IGF-1 level and its prognostic role after liver transplantation (LT.From April 2010 to May 2011, 31 patients were prospectively enrolled (25/6 M/F; mean age±SEM: 55.2±1.4 years, and IGF-1 serum levels were assessed preoperatively and at 15, 30, 90, 180 and 365 days after transplantation. The influence of the donor and recipient characteristics (age, use of extended criteria donor grafts, D-MELD and incidence of early allograft dysfunction on hormonal concentration was analyzed. The prognostic role of IGF-1 level on patient survival and its correlation with routine liver function tests were also investigated.All patients showed low preoperative IGF-1 levels (mean±SEM: 29.5±2.1, and on postoperative day 15, a significant increase in the IGF-1 plasma level was observed (102.7±11.7 ng/ml; p65 years or extended criteria donor grafts. An inverse correlation between IGF-1 and bilirubin serum levels at day 15 (r = -0.3924, p = 0.0320 and 30 (r = -0.3894, p = 0.0368 was found. After multivariate analysis, early (within 15 days IGF-1 normalization [Exp(b = 3.913; p = 0.0484] was the only prognostic factor associated with an increased 3-year survival rate.IGF-1 postoperative levels are correlated with the graft's quality and reflect liver function. Early IGF-1 recovery is associated with a higher 3-year survival rate after LT.

  14. Comparative Proteomic Analysis of the Graft Unions in Hickory (Carya cathayensis Provides Insights into Response Mechanisms to Grafting Process

    Directory of Open Access Journals (Sweden)

    Daoliang Yan

    2017-04-01

    Full Text Available Hickory (Carya cathayensis, a tree with high nutritional and economic value, is widely cultivated in China. Grafting greatly reduces the juvenile phase length and makes the large scale cultivation of hickory possible. To reveal the response mechanisms of this species to grafting, we employed a proteomics-based approach to identify differentially expressed proteins in the graft unions during the grafting process. Our study identified 3723 proteins, of which 2518 were quantified. A total of 710 differentially expressed proteins (DEPs were quantified and these were involved in various molecular functional and biological processes. Among these DEPs, 341 were up-regulated and 369 were down-regulated at 7 days after grafting compared with the control. Four auxin-related proteins were down-regulated, which was in agreement with the transcription levels of their encoding genes. The Kyoto Encyclopedia of Genes and Genomes (KEGG analysis showed that the ‘Flavonoid biosynthesis’ pathway and ‘starch and sucrose metabolism’ were both significantly up-regulated. Interestingly, five flavonoid biosynthesis-related proteins, a flavanone 3-hyfroxylase, a cinnamate 4-hydroxylase, a dihydroflavonol-4-reductase, a chalcone synthase, and a chalcone isomerase, were significantly up-regulated. Further experiments verified a significant increase in the total flavonoid contents in scions, which suggests that graft union formation may activate flavonoid biosynthesis to increase the content of a series of downstream secondary metabolites. This comprehensive analysis provides fundamental information on the candidate proteins and secondary metabolism pathways involved in the grafting process for hickory.

  15. Dynamics of solvent-free grafted nanoparticles

    KAUST Repository

    Chremos, Alexandros; Panagiotopoulos, Athanassios Z.; Koch, Donald L.

    2012-01-01

    as well as grafted nanoparticles in a melt were compared to a reference system of bare (ungrafted) particles in a melt. Whereas longer chains lead to a larger hydrodynamic radius and lower relative diffusivity for grafted particles in a melt, bulk solvent

  16. The influence of Australian eye banking practices on corneal graft survival.

    Science.gov (United States)

    Keane, Miriam C; Lowe, Marie T; Coster, Douglas J; Pollock, Graeme A; Williams, Keryn A

    2013-08-19

    To identify eye banking practices that influence corneal graft survival. Prospective cohort study of records of 19,254 followed corneal grafts in 15160 patients, submitted to the Australian Corneal Graft Registry between May 1985 and July 2012. Influence of corneal preservation method (organ culture, moist pot, Optisol, other); death-to-enucleation, death-to-preservation and enucleation-to-graft times; transportation by air; graft era; and indication for graft on probability of graft survival at most recent follow-up. In multivariate analysis, 919 penetrating grafts performed using corneas transported interstate by air exhibited worse survival than 14,684 grafts performed using corneas retrieved and used locally (hazard ratio [HR], 1.44; 95% CI, 1.21-1.73; P = 0.001). This was also the case for traditional lamellar grafts (64 corneas transported by air and 813 used locally; HR, 1.69; 95% CI, 1.03-2.78; P = 0.038). Indication for graft influenced survival of penetrating grafts (4611 keratoconus, 727 emergency or high-risk, 10,265 other indication; global P < 0.001) and traditional lamellar grafts (65 keratoconus, 212 emergency or high-risk, 600 other indication; global P < 0.001). The preservation medium in which corneas used for traditional lamellar grafts were stored exerted a marginal influence on graft survival (global P = 0.047). Donor corneas transported interstate exhibited poorer survival after transplantation than those retrieved and grafted locally. Higher proportions of emergency procedures involving transported corneas did not account for this difference. Where possible, efforts to avoid transportation of corneal tissue by air freight within Australia may be warranted.

  17. Comprehensive Mineral Nutrition Analysis of Watermelon Grafted onto Two Different Rootstocks

    Directory of Open Access Journals (Sweden)

    Yuan Huang

    2016-03-01

    Full Text Available Grafting is a widely used practice in fruit-bearing vegetables. However, why grafting affects plant growth, fruit yield, and quality, especially from the aspect of mineral nutrition, remains unclear. In this study, watermelon cultivar ‘Zaojia 8424’ was grafted onto bottle gourd ‘Jingxinzhen 1’ (Lagenaria siceraria and pumpkin ‘Qingyanzhen 1’ (Cucurbita maxima × C. moschata. Non-grafted plants were used as the control. Results show that rootstock grafting significantly increases plant growth and single fruit weight of watermelon. Watermelon grafted onto rootstocks, especially pumpkin, exhibits significantly higher root volume, root surface area, and number of root tips and forks in comparison with non-grafted plants. Fruit flesh, rind firmness, and rind thickness were enhanced by grafting. However, fruit soluble solids and taste significantly decreased in plants grafted onto pumpkin. The total uptake (mg ⋅ plant−1 and concentration (mg ⋅ g−1 DW of N, K, Ca, Fe, Mg, and Mn in root, stem, leaf, fruit rind, and flesh were generally higher in grafted plants compared to non-grafted ones, especially for N of pumpkin rootstock-grafted plants. The total uptake of nutrients of plants grafted onto bottle gourd and pumpkin was increased by 30.41% and 49.14% at fruit development stage and by 21.33% and 47.46% at fruit maturation stage, respectively, compared with non-grafted plants. We concluded that watermelon grafting onto suitable rootstocks can increase the uptake of mineral nutrition, especially for N in the pumpkin rootstock grafted plants, thereby affecting plant growth, fruit yield, and quality.

  18. Feature Hepatitis: The Dangers of Hepatitis: What you should know from A to E

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Feature Hepatitis The Dangers of Hepatitis: What you should know from A to E ... drugs. In some cases, hepatitis lasts a lifetime. Hepatitis: Acute or Chronic? Acute hepatitis is the initial ...

  19. Hepatitis C virus core protein induces hepatic steatosis via Sirt1-dependent pathway.

    Science.gov (United States)

    Zhang, Chuanhai; Wang, Jingjing; Zhang, Hanlin; Liu, Shunai; Lee, Hyuek Jong; Jin, Wanzhu; Cheng, Jun

    2018-05-01

    Hepatic steatosis is a common feature of patients with chronic hepatitis C. Previous reports have shown that the overexpression of hepatitis C virus core-encoding sequences (hepatitis C virus genotypes 3a and 1b) significantly induces intracellular triglyceride accumulation. However, the underlying mechanism has not yet been revealed. To investigate whether Sirt1 is involved in hepatitis C virus-mediated hepatic steatosis, the overexpression of hepatitis C virus core 1b protein and Sirt1 and the knockdown of Sirt1 in HepG2 cells were performed. To confirm the results of the cellular experiment liver-specific Sirt1 KO mice with lentivirus-mediated hepatitis C virus core 1b overexpression were studied. Our results show that hepatitis C virus core 1b protein overexpression led to the accumulation of triglycerides in HepG2 cells. Notably the expression of PPARγ2 was dramatically increased at both the mRNA and protein levels by hepatitis C virus core 1b overexpression. The protein expression of Sirt1 is an upstream regulator of PPARγ2 and was also significantly increased after core 1b overexpression. In addition, the overexpression or knockdown of Sirt1 expression alone was sufficient to modulate p300-mediated PPARγ2 deacetylation. In vivo studies showed that hepatitis C virus core protein 1b-induced hepatic steatosis was attenuated in liver-specific Sirt1 KO mice by downregulation of PPARγ2 expression. Sirt1 mediates hepatitis C virus core protein 1b-induced hepatic steatosis by regulation of PPARγ2 expression. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Composite vascular grafts with high cell infiltration by co-electrospinning

    International Nuclear Information System (INIS)

    Tan, Zhikai; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-01-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  1. Composite vascular grafts with high cell infiltration by co-electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Zhikai, E-mail: tanzk@hnu.edu.cn; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-10-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  2. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  3. Hepatitis B Test

    Science.gov (United States)

    ... Links Patient Resources For Health Professionals Subscribe Search Hepatitis B Testing Send Us Your Feedback Choose Topic At ... Known As HBV Tests Hep B anti-HBs Hepatitis B Surface Antibody HBsAg Hepatitis B Surface Antigen HBeAg ...

  4. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    Science.gov (United States)

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  5. The effect of carbon dioxide therapy on composite graft survival.

    Science.gov (United States)

    Durães, Eliana Ferreira Ribeiro; Durães, Leonardo de Castro; Carneiro, Fabiana Pirani; Lino, Ruy de Souza; Sousa, João Batista de

    2013-08-01

    To investigate the effect of carboxytherapy in auricular composite grafts in rabbits. An experimental study was conducted using 20 rabbits randomly assigned to a treatment group of carboxytherapy or a control group of saline solution. In each ear, a circular graft with 1.5 cm or 2 cm of diameter was amputated and reattached. Animals underwent carbon dioxide or saline injection four times during the experiment. We analyzed clinical evolution of the animals, grafts survival, histopathology features and histomorphometry of collagen. The treated group had a significantly lower weight gain (p=0.038). Histopathology was not significantly different between groups. There was an increase in amount of collagen in 2 cm grafts submitted to carbon dioxide therapy (p=0.003). Carboxytherapy didn't influence graft survival rate for 1.5 cm grafts or 2 cm grafts (p=0.567 and p=0.777, respectively). Carbon dioxide therapy increased the amount of collagen in 2 cm grafts. CO2 was not significantly different from saline infusion on composite grafts survival, but this study suggests that there is a mechanical effect caused by distension which favored graft survival.

  6. Synthesis of Radiation Grafted Polymer Matrices for Separation and Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhardwaj, Y K; Virendra, K; Goel, N K; Sarma, K S.S.; Sabharwal, S [Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2012-09-15

    Grafting of acrylonitrile onto non-woven porous polypropylene fibre sheet using electron beam was carried out by post-irradiation grafting. Grafting extent of {approx}125% was achieved. The grafted nitrile groups were amidoximated and studied for uranium uptake from sea water and heavy metal ions (Co{sup 2+}, Ni{sup 2+}, Mn{sup 2+}, and Cd{sup 2+}) from aqueous solutions. Adsorption and elution of adsorbed ions in suitable eluents was studied. The grafting process was upgraded to pilot scale to obtain 1x1 m{sup 2} sheets. Mutual radiation grafting technique was used for grafting of vinylbenzyltrimethyl ammonium chloride, [2- (methacryloyloxy)ethyl] trimethylammonium chloride and [2-(acryloyloxyethyl)]trimethylammonium chloride onto cotton cellulose substrate. The grafted matrices showed significantly higher water uptake and good water retention properties. The antibacterial efficacy of the grafted products was found to be a function of extent of grafting and the type of bacteria (Escherichia coli, Pseudomonas flourescens, Staphylococcus aureus and Bacillus cereus). PVBT-g-cotton was studied for its protein adsorption behaviour in continuous column process using Bovine serum albumin (BSA) as a model protein. Mutual radiation grafting technique was used to graft acrylic acid on micrometer thick micro-porous polypropylene membrane. Contact angle measurement studies showed that initial grafting as well as radiation treatment of poly(propylene) in aqueous medium and in presence of Mohr's salt enhances its affinity towards the grafting solution. The enhancement in the polar component of surface energy of treated polypropylene membrane is the primary cause of grafting enhancement. The membranes grafted to an extent of {approx}20% were found to perform comparably with the battery separator presently being used by battery industry. Acrylic acid was grafted to Teflon scrap by mutual radiation grafting technique. The grafting extent decreased with increasing dose rate and

  7. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  8. Pinch grafting for chronic venous leg ulcers in general practice

    OpenAIRE

    Steele, Keith

    1985-01-01

    Twenty-five patients with chronic venous leg ulcers were treated in general practice by pinch grafting. Fifteen of the ulcers (60%) were completely healed one year after grafting. Prior to grafting 19 patients (76%) complained of daily pain in the ulcer. These patients experienced complete relief from pain after grafting. Pinch grafting is a simple, safe and effective therapy when applied in a domiciliary environment.

  9. The caudal septum replacement graft.

    Science.gov (United States)

    Foda, Hossam M T

    2008-01-01

    To describe a technique for reconstructing the lost tip support in cases involving caudal septal and premaxillary deficiencies. The study included 120 patients with aesthetic and functional nasal problems resulting from the loss of caudal septal and premaxillary support. An external rhinoplasty approach was performed to reconstruct the lost support using a cartilaginous caudal septum replacement graft and premaxillary augmentation with Mersilene mesh. The majority of cases (75%) involved revisions in patients who had previously undergone 1 or more nasal surgical procedures. A caudal septum replacement graft was combined with premaxillary augmentation in 93 patients (77.5%). The mean follow-up period was 3 years (range, 1-12 years). The technique succeeded in correcting the external nasal deformities in all patients and resulted in a significant improvement in breathing in 74 patients (86%) with preoperative nasal obstruction. There were no cases of infection, displacement, or extrusion. The caudal septum replacement graft proved to be very effective in restoring the lost tip support in patients with caudal septal deficiency. Combining the graft with premaxillary augmentation using Mersilene mesh helped increase support and stability over long-term follow-up.

  10. Seroprevalence and risk factors of Hepatitis B and Hepatitis C ...

    African Journals Online (AJOL)

    Undertaking blood transfusion, tattooing and sharing of needles were associated with hepatitis C infection (P=0.001). HBV was not associated with any of the risk factors (P>0.05). Conclusion: Our findings suggest a high prevalence of hepatitis B and hepatitis C among pregnant women; blood transfusion, tattooing and ...

  11. Grafting heterogeneous catalyst with gamma radiation

    International Nuclear Information System (INIS)

    Garnett, J.L.; Long, M.A.; Levot, R.G.

    1984-01-01

    A process for the production of a heterogeneous catalyst comprises the steps of: irradiating an organic macromolecular substrate or a metal substrate with ionising or ultra violet radiation in the presence of a monomer selected from the group consisting of o-, m-, or p- styryl diphenyl phosphine and o-, m- or p- phenyl acrylyl diphenyl phosphine, to graft the monomer to the substrate; and reacting the graft copolymer with a homogeneous catalyst selected from the group consisting of catalytic metal salts and catalytic organometallic complexes such that the graft copolymer conjugate becomes a ligand of the catalyst

  12. Lower doses venlafaxine-associated toxic hepatitis in a patient with chronic hepatitis

    International Nuclear Information System (INIS)

    Sencan, I.; Sahin, I.; Ozcetin, A.

    2003-01-01

    Toxic hepatitis is observed with high doses of Venlafaxine. But toxic hepatitis has not been yet reported at lower doses of Venlafaxine such as 37.5 mg per day. In this case report, a case of Venlafaxine associated toxic hepatitis with lower doses in patient with history of chronic hepatitis is presented. We suggest that liver function should be regularly monitored in patients with history of chronic hepatitis receiving Venlafaxine even at lower doses and even when their liver enzymes are normal. (author)

  13. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    Science.gov (United States)

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  14. In vivo evaluation of wound bed reaction and graft performance after cold skin graft storage: new targets for skin tissue engineering.

    Science.gov (United States)

    Knapik, Alicia; Kornmann, Kai; Kerl, Katrin; Calcagni, Maurizio; Schmidt, Christian A; Vollmar, Brigitte; Giovanoli, Pietro; Lindenblatt, Nicole

    2014-01-01

    Surplus harvested skin grafts are routinely stored at 4 to 6°C in saline for several days in plastic surgery. The purpose of this study was to evaluate the influence of storage on human skin graft performance in an in vivo intravital microscopic setting after transplantation. Freshly harvested human full-thickness skin grafts and split-thickness skin grafts (STSGs) after storage of 0, 3, or 7 days in moist saline at 4 to 6°C were transplanted into the modified dorsal skinfold chamber, and intravital microscopy was performed to evaluate vessel morphology and angiogenic change of the wound bed. The chamber tissue was harvested 10 days after transplantation for evaluation of tissue integrity and inflammation (hematoxylin and eosin) as well as for immunohistochemistry (human CD31, murine CD31, Ki67, Tdt-mediated dUTP-biotin nick-end labelling). Intravital microscopy results showed no differences in the host angiogenic response between fresh and preserved grafts. However, STSGs and full-thickness skin grafts exhibited a trend toward different timing and strength in capillary widening and capillary bud formation. Preservation had no influence on graft quality before transplantation, but fresh STSGs showed better quality 10 days after transplantation than 7-day preserved grafts. Proliferation and apoptosis as well as host capillary in-growth and graft capillary degeneration were equal in all groups. These results indicate that cells may activate protective mechanisms under cold conditions, allowing them to maintain function and morphology. However, rewarming may disclose underlying tissue damage. These findings could be translated to a new approach for the design of full-thickness skin substitutes.

  15. The communication of endogenous biomolecules (RNA, DNA, protein, hormone) via graft union might play key roles in the new traits formation of graft hybrids

    International Nuclear Information System (INIS)

    Khan, I.A.; Ghazal, L.; Arsalan, M.H.; Siddiqui, M.F.

    2018-01-01

    Plant graft hybridization is a fact of a sexual hybridization in which heritable changes trigger by grafting, it can produce hereditable variation types desired by breeders and can be used as a new method for germplasm innovation. This paper aimed to discuss new phenotypic variations such as phenotypic diversity and polyploidy formation discovered in recent years, new evidence supporting genetic material exchange between the rootstock and scion, and the timeliness, direction, and genetic stability of trait formation induced by graft hybridization. The unresolved mechanisms of trait variation were also discussed, and the relationship with exchange of chloroplast DNA (cpDNA) genetic information, horizontal gene transfer events of chloroplast and mitochondria, miRNA-mediated post-transcriptional regulation, and pressure-driven trait variations from graft hybridization were performed to clarify the relevant questions. Finally, the future research trend and key questions of graft hybridization were identified. Three clear conclusions for graft hybridization are presented: the new traits of graft hybrids have stable genetic characteristics and can be controlled via selection different genetic plant by grafting, and the products of graft hybrids were safer than those of transgenic plants. (author)

  16. Radiation Grafted Polymer Membranes for Fuel Cell Applications

    International Nuclear Information System (INIS)

    Scherer, G.G.; Wallasch, F.; Ben Youcef, H.; Gubler, L.

    2012-01-01

    Partially fluorinated proton exchange membranes prepared via radiation induced graft copolymerization ('radiation grafting') offer the prospect of cost-effective and tailor made membrane electrolytes for the polymer electrolyte fuel cell (PEFC). The composition and structure of radiation grafted membranes can be adjusted in a broad range to balance the different requirements of proton transport and mechanical robustness. Based on the earlier work on Styrene grafting, the novel monomer combination α-methyl-styrene/methacrylonitrile (AMS/MAN) is introduced for improved stability in the prevailing fuel cell environment. Successful fuel cell experiments proved the concept. (author)

  17. Radiation Grafted Polymer Membranes for Fuel Cell Applications

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, G G; Wallasch, F; Ben Youcef, H; Gubler, L [Electrochemistry Laboratory, Paul Scherrer Institut, CH-5232 Villigen (Switzerland)

    2012-09-15

    Partially fluorinated proton exchange membranes prepared via radiation induced graft copolymerization ('radiation grafting') offer the prospect of cost-effective and tailor made membrane electrolytes for the polymer electrolyte fuel cell (PEFC). The composition and structure of radiation grafted membranes can be adjusted in a broad range to balance the different requirements of proton transport and mechanical robustness. Based on the earlier work on Styrene grafting, the novel monomer combination {alpha}-methyl-styrene/methacrylonitrile (AMS/MAN) is introduced for improved stability in the prevailing fuel cell environment. Successful fuel cell experiments proved the concept. (author)

  18. Atypical leiomyoma arising in a hepatic vein with extension into the inferior vena cava and right atrium

    International Nuclear Information System (INIS)

    Dunlap, H.J.; Udjus, K.

    1990-01-01

    We report an atypical leiomyoma arising in a hepatic vein and extending into the inferior vena cava and right atrium in a fourteen year old boy. US, CT and MRI facilitated diagnosis and removal of this tumor. (orig.)

  19. Excellent Aesthetic and Functional Outcome After Fractionated Carbon Dioxide Laser Skin Graft Revision Surgery: Case Report and Review of Laser Skin Graft Revision Techniques.

    Science.gov (United States)

    Ho, Derek; Jagdeo, Jared

    2015-11-01

    Skin grafts are utilized in dermatology to reconstruct a defect secondary to surgery or trauma of the skin. Common indications for skin grafts include surgical removal of cutaneous malignancies, replacement of tissue after burns or lacerations, and hair transplantation in alopecia. Skin grafts may be cosmetically displeasing, functionally limiting, and significantly impact patient's quality-of-life. There is limited published data regarding skin graft revision to enhance aesthetics and function. Here, we present a case demonstrating excellent aesthetic and functional outcome after fractionated carbon dioxide (CO2) laser skin graft revision surgery and review of the medical literature on laser skin graft revision techniques.

  20. Revascularisation of fresh compared with demineralised bone grafts in rats

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    2001-01-01

    Revascularisation of bone grafts is influenced by both the anatomical origin and the pre-implantation processing of the graft. We investigated the revascularisation by entrapment of 141Ce (cerium)-labelled microspheres in large, fresh and demineralised syngeneic grafts of predominantly cancellous...... (iliac bone) or cortical (tibial diaphysis) bone three weeks after heterotopic implantation in rats. The mean (SD) 141Ce deposition index (counts per minute (cpm) of mg recovered implant/cpm of mg host iliac bone) was higher in fresh iliac bone grafts, 0.98 (0.46) compared to that of demineralised iliac...... bone, 0.32 (0.20), p bone grafts, 0.51 (0.27), p = 0.007. We found no significant difference in the mean 141Ce deposition index between fresh tibial bone grafts and demineralised tibial bone grafts, 0.35 (0.42), p = 0.4, or between demineralised tibial grafts and demineralised...

  1. Fusion Rates of Different Anterior Grafts in Thoracolumbar Fractures.

    Science.gov (United States)

    Antoni, Maxime; Charles, Yann Philippe; Walter, Axel; Schuller, Sébastien; Steib, Jean-Paul

    2015-11-01

    Retrospective CT analysis of anterior fusion in thoracolumbar trauma. The aim of this study was to compare fusion rates of different bone grafts and to analyze risk factors for pseudarthrosis. Interbody fusion is indicated in anterior column defects. Different grafts are used: autologous iliac crest, titanium mesh cages filled with cancellous bone, and autologous ribs. It is not clear which graft offers the most reliable fusion. Radiologic data of 116 patients (71 men, 45 women) operated for type A2, A3, B, or C fractures were analyzed. The average age was 44.6 years (range, 16-75 y) and follow-up was 2.7 years (range, 1-9 y). All patients were treated by posterior instrumentation followed by an anterior graft: 53 cases with iliac crest, 43 cases with mesh cages, and 20 with rib grafts. Fusion was evaluated on CT and classified into complete fusion, partial fusion, unipolar pseudarthrosis, and bipolar pseudarthrosis. Iliac crest fused in 66%, cages in 98%, and rib grafts in 90%. The fusion rate of cages filled with bone was significantly higher as the iliac graft fusion rate (P=0.002). The same was applied to rib grafts compared with iliac crest (P=0.041). Additional bone formation around the main graft, bridging both vertebral bodies, was observed in 31 of the 53 iliac crests grafts. Pseudarthrosis occurred more often in smokers (P=0.042). A relationship between fracture or instrumentation types, sex, age, BMI, and fusion could not be determined. Tricortical iliac crest grafts showed an unexpected high pseudarthrosis rate in thoracolumbar injuries. Their cortical bone is dense and their fusion surface is small. Rib grafts led to a better fusion when used in combination with the cancellous bone from the fractured vertebral body. Titanium mesh cages filled with cancellous bone led to the highest fusion rate and built a complete bony bridge between vertebral bodies. Smoking seemed to influence fusion. Case control study, Level III.

  2. Fetal hypothalamic transplants into brain irradiated rats: Graft morphometry and host behavioral responses

    International Nuclear Information System (INIS)

    Pearlman, S.H.; Rubin, P.; White, H.C.; Wiegand, S.J.; Gash, D.M.

    1990-01-01

    This study was designed to test the hypothesis that neural implants can ameliorate or prevent some of the long-term changes associated with CNS irradiation. Using a rat model, the initial study focused on establishing motor, regulatory, and morphological changes associated with brain radiation treatments. Secondly, fetal hypothalamic tissue grafts were placed into the third ventricle of rats which had been previously irradiated. Adult male Long Evans rats received one of three radiation doses (15, 22.5, ampersand 30 Gy) or no radiation. Three days after irradiation, 7 animals in each dose group received an embryonic day 17 hypothalamic graft into the third ventricle while the remaining 8-9 animals in each group received injections of vehicle solution (sham). Few changes were observed in the 15 and 22.5 Gy animals, however rats in the 30 Gy treatment group showed stereotypic and ambulatory behavioral hyperactivity 32 weeks after irradiation. Regulatory changes in the high dose group included decreased growth rate and decreased urine osmolalities, but these measures were extremely variable among animals. Morphological results demonstrated that 30 Gy irradiated animals showed extensive necrosis primarily in the fimbria, which extended into the internal capsule, optic nerve, hippocampus, and thalamus. Hemorrhages were found in the hippocampus, thalamus, and fimbria. Defects in the blood-brain barrier also were evident by entry of intravascularly injected horseradish peroxidase into the parenchyma of the brain. Animals in the 30 Gy grafted group showed fewer behavioral changes and less brain damage than their sham grafted counterparts. Specifically, activity measures were comparable to normal levels, and a dilute urine was not found in the 30 Gy implanted rats. Morphological changes support these behavioral results since only two 30 Gy implanted rats showed necrosis

  3. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Donate Today Enroll in 123 What is Hepatic Encephalopathy? Hepatic Encephalopathy, sometimes referred to as portosystemic encephalopathy or PSE, is a condition that causes temporary ...

  4. The Effect of Platelet-Rich Plasma on Survival of the Composite Graft and the Proper Time of Injection in a Rabbit Ear Composite Graft Model

    Directory of Open Access Journals (Sweden)

    Hyun Nam Choi

    2014-11-01

    Full Text Available BackgroundAdministration of growth factors has been associated with increased viability of composite grafts greater than 1-cm in diameter. Platelet-rich plasma (PRP contains many of the growth factors studied. In this study, we evaluate the effect of PRP injection on composite graft viability and the proper time for injection.MethodsA total of 24 New Zealand White rabbits were divided into four groups. Autologous PRP was injected into the recipient sites three days before grafting in group 1, on the day of grafting in group 2, and three days after grafting in group 3. Group 4 served as control without PRP administration. Auricular composite grafts of 3-cm diameter were harvested and grafted back into place after being rotated 180 degrees. Median graft viability and microvessel density were evaluated at day 21 of graft via macroscopic photographs and immunofluorescent staining, respectively.ResultsThe median graft survival rate was 97.8% in group 1, 69.2% in group 2, 55.7% in group 3, and 40.8% in the control group. The median vessel counts were 34 (per ×200 HPF in group 1, 24.5 in group 2, 19.5 in group 3, and 10.5 in the control group.ConclusionsThis study demonstrates that PRP administration is associated with increased composite graft viability. All experimental groups showed a significantly higher survival rate and microvessel density, compared with the control group. Pre-administration of PRP was followed by the highest graft survival rate and revascularization. PRP treatments are minimally invasive, fast, easily applicable, and inexpensive, and offer a potential clinical pathway to larger composite grafts.

  5. Hepatitis A Virus and Hepatitis E Virus: Emerging and Re-Emerging Enterically Transmitted Hepatitis Viruses.

    Science.gov (United States)

    Lemon, Stanley M; Walker, Christopher M

    2018-05-07

    Over the past two decades, progress in understanding human infections with hepatitis A virus (HAV) and hepatitis E virus (HEV) has been eclipsed by the priority of combating persistent hepatitis B virus (HBV) and hepatitis C virus (HCV) infections. During that time, the global burden of liver disease caused by enteric hepatitis viruses has not abated. Because of vaccines, hepatitis A has become increasingly a disease of adults instead of early childhood in many regions of the world, resulting in an age-related shift toward more severe disease. HEV has remained endemic in many developing countries, and in well-developed, economically advanced countries it is now recognized as a cause of chronic, progressive liver disease in individuals with compromised immunity. The goal of this collection of articles is to review recent progress and to shine a bright light on gaps in our understanding of how these viruses replicate, cause disease, interact with the liver and host immune system, and are transmitted, along with prospects for improved control in human populations. Renewed efforts to study and compare HAV and HEV biology in humans and animal models have high potential to enhance our understanding of host-pathogen balance in the liver, and may contribute ultimately to the control of other infectious diseases of the liver. Copyright © 2018 Cold Spring Harbor Laboratory Press; all rights reserved.

  6. Grafting of acrylamide onto synthetic co polyamide by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamoud, M R; Qamhieyh, E A [Chemistry Dept., College of Ibn Al-Haitham Baghdad university-Adhamiyah-Baghdad- (Iraq)

    1995-10-01

    Grafted copolymer was prepared by using gamma irradiation to graft acrylamide onto polymeric molecule prepared by interfacial condensation between two diamine molecules like 1,2 diamino propane and 1,6 diamino-hexane in aqueous layer with sebacoyl chloride in organic layer. The resulted co polyamide was grafted with acrylamide using gamma irradiation. The optimum conditions of grafting reaction were found, also various factors such as the effect of solvents, redox systems and the role water on the radiochemical grafting were studied. Many techniques were used in the characterization of the copolymer before and after grafting. 8 figs.,.

  7. An Introduction to the Septal Extension Graft

    Directory of Open Access Journals (Sweden)

    Myung-Hoon Kim

    2014-01-01

    Full Text Available The septal extension graft is a very useful method of controlling nasal lengthening and tip projection, rotation, and shape by fixing a graft to the septum, which leads to a strong supporting structure. Enhancing graft stability is important for better long-term outcomes and minimizing complications or relapse, and even more efficient application of these methods is needed for East Asians who lack enough cartilage to be harvested in addition to possessing a weak cartilage framework. In this paper, the methods for overcoming the drawbacks of the septal extension graft, such as instability, a fixed tip, and insufficiency of cartilage, are presented, and the applications of each method for greater satisfaction with surgical outcomes are also discussed.

  8. Corneal Graft Rejection: Incidence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafii

    2008-12-01

    Full Text Available

    PURPOSE: To determine the incidence and risk factors of late corneal graft rejection after penetrating keratoplasty (PKP. METHODS: Records of all patients who had undergone PKP from 2002 to 2004 without immunosuppressive therapy other than systemic steroids and with at least one year of follow up were reviewed. The role of possible risk factors such as demographic factors, other host factors, donor factors, indications for PKP as well as type of rejection were evaluated. RESULTS: During the study period, 295 PKPs were performed on 286 patients (176 male, 110 female. Mean age at the time of keratoplasty was 38±20 (range, 40 days to 90 years and mean follow up period was 20±10 (range 12-43 months. Graft rejection occurred in 94 eyes (31.8% at an average of 7.3±6 months (range, 20 days to 39 months after PKP. The most common type of rejection was endothelial (20.7%. Corneal vascularization, regrafting, anterior synechiae, irritating sutures, active inflammation, additional anterior segment procedures, history of trauma, uncontrolled glaucoma, prior graft rejection, recurrence of herpetic infection and eccentric grafting increased the rate of rejection. Patient age, donor size and bilateral transplantation had no significant influence on graft rejection. CONCLUSION: Significant risk factors for corneal graft rejection include

  9. [Hepatic cell transplantation. Technical and methodological aspects].

    Science.gov (United States)

    Pareja, Eugenia; Martínez, Amparo; Cortés, Miriam; Bonora, Ana; Moya, Angel; Sanjuán, Fernando; Gómez-Lechón, M José; Mir, José

    2010-03-01

    Hepatic cell transplantation consists of grafting already differentiated cells such as hepatocytes. Human hepatocytes are viable and functionally active. Liver cell transplantation is carried out by means of a 3-step method: isolation of hepatocytes from donor liver rejected for orthotopic transplantation, preparing a cell suspension for infusion and, finally, hepatocytes are implanted into the recipient. There are established protocols for the isolation of human hepatocytes from unused segments of donor livers, based on collagenase digestion of cannulated liver tissue at 37 degrees C. The hepatocytes can be used fresh or cryopreserved. Cryopreservation of isolated human hepatocytes would then be available for planned use. In cell transplant, the important aspects are: infusion route, number of cells, number of infusions and viability of the cells. The cells are infused into the patient through a catheter inserted via portal vein or splenic artery. Liver cell transplantation allows liver tissue to be used that would, otherwise, be discarded, enabling multiple patients to be treated with hepatocytes from a single tissue donor. Copyright 2009 AEC. Published by Elsevier Espana. All rights reserved.

  10. The hepatic bridge.

    Science.gov (United States)

    Sugarbaker, Paul H

    2018-07-01

    The hepatic bridge forms a tunnel of liver parenchyma that may obscure peritoneal metastases associated with the round ligament. Visualization and then resection of nodules associated with this structure is necessary. The incidence of a hepatic bridge and the extent that it covered the round ligament was determined in consecutive patients. Extent of coverage of the round ligament by the hepatic bridge was determined: Class 1 indicates up to one-third of the round ligament obscured, Class 2 up to two-thirds and Class 3 more than two-thirds. In 102 patients in whom the round ligament of the liver could be completely visualized, 50 had a hepatic bridge. Class 1 was 22 (44%) of the bridges, Class 2 was 16 (32%) and Class 3 was 12 (24%). A hepatic bridge was more frequently present in 28 of 45 male patients (62%) vs. 22 of 57 female patients (38%). Approximately one-half of our patients having cytoreductive surgery for peritoneal metastases were observed to have a hepatic bridge. Up to 56% of these patients have Class 2 or 3 hepatic bridge and may require division of the hepatic bridge to completely visualize the contents of the tunnel created by this structure. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  11. Grafted SiC nanocrystals

    DEFF Research Database (Denmark)

    Saini, Isha; Sharma, Annu; Dhiman, Rajnish

    2017-01-01

    ), raman spectroscopy and X-ray diffraction (XRD) measurements. UV–Visible absorption spectroscopy was used to study optical properties such as optical energy gap (Eg), Urbach's energy (Eu), refractive index (n), real (ε1) and imaginary (ε2) parts of dielectric constant of PVA as well as PVA......Polyvinyl alcohol (PVA) grafted SiC (PVA-g-SiC)/PVA nanocomposite was synthesized by incorporating PVA grafted silicon carbide (SiC) nanocrystals inside PVA matrix. In-depth structural characterization of resulting nanocomposite was carried out using fourier transform infrared spectroscopy (FTIR...

  12. Hepatic volumetry with PhotoShop in personal computer.

    Science.gov (United States)

    Lu, Yi; Wu, Zheng; Liu, Chang; Wang, Hao-Hua

    2004-02-01

    Convenient way to clarify liver volume or tumor volume in the liver is eagerly demanded by hepatobiliary surgeons, for so many aspects of clinical work need to know the liver volumetry. At present, some methods have been used to measure the liver volumetry, such as computed tomography (CT) scans, three-dimensional ultrasound volumetric system([1]) and 3-dimensional sonography([2,3]) et al. But enough volumetric information was failed to obtain by surgeons and a new way of measuring the liver volumetry that can be operated by themselves is exigent. Whereas we devise a new method of using PhotoShop in personal computer to measure the liver volumetry. A piece of whole CT film was transformed to a high quality digitized image by digital camera or scanner and then the digitized image was conducted as JPEG file into personal computer. The JPEG image file of CT film was opened by PhotoShop. Determining the edge of interested areas, and the data of pixel values of the interested areas divided by 1 cm2 pixel value will produce the actual area with the unit of square centimeter. If section thickness of CT scan is 1 cm, the sum of the areas of the liver or tumor in all sections naturally is the volume of the liver or tumor. Comparison of 10 hepatic volumes gained by this method and those gained by the GE Prospeed CT set showed a good relativity between the two groups. The volumes of three right lobes were calculated by this method before lobectomy and their real volumes were obtained postoperatively by a volumenometer. Their variation was limited to 5%. Hepatic volume obtained by PhotoShop is reliable. This method can be used to measure hepatic volume perfectly to meet clinical demand, and many parameters such as liver resection rate, graft volume can be achieved. The disadvantage of this method is the step of copying the pixel value from PhotoShop to Microsoft Excel.

  13. Accessory hepatic vein: MR imaging

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Rho, Tack Soo; Cha, Sang Hoon; Park, Cheol Min; Cha, In Ho

    1995-01-01

    To evaluate the MR appearance of the accessory hepatic veins. The study included 87 consecutive patients for whom abdominal MR images were obtained. The subjects who had liver lesion or hepatic vascular abnormalities were excluded. Couinaud classified accessory hepatic veins into inferior and middle right hepatic veins. Our major interests were evaluation of the incidence, morphology, and location of the accessory hepatic vein. Inferior right hepatic vein was demonstrated in 43 out of 87 patients (49%). The morphology was linear in 35 patients (80.5%), and V-shaped in 8 patients (19.5%). In 40 patients (93%), the inferior right hepatic vein was located in the posteroinferior aspect of the right lobe. Middle right hepatic vein was demonstrated in 7 out of 87 patients (8%). All were single linear in morphology, combined with the inferior right hepatic vein, and located between the right hepatic vein and inferior right hepatic vein. The accessory hepatic vein was demonstrated in 49% among the Korean adult population, and was located in posteroinferior portion of the liver, in 93%

  14. Features of Hepatitis in Hepatitis-associated Aplastic Anemia: Clinical and Histopathologic Study.

    Science.gov (United States)

    Patel, Kalyani R; Bertuch, Alison; Sasa, Ghadir S; Himes, Ryan W; Wu, Hao

    2017-01-01

    Hepatitis-associated aplastic anemia (HAA) is a rare variant of aplastic anemia in which patients present with severe pancytopenia after an episode of acute hepatitis. The marrow failure is often rapid, severe, and usually fatal if untreated. The preceding hepatitis is largely under-studied. Retrospective study of the clinical and histopathologic features of hepatitis in pediatric patients who subsequently developed aplastic anemia and comparison with consecutive cases of acute liver failure and random cases of autoimmune hepatitis during the same time frame. All 7 patients of HAA had significant elevations in aminotransferases and conjugated hyperbilirubinemia at initial presentation. Echoing liver function indices, cholestatic hepatitis with sinusoidal obstruction-type endothelial injury was seen histomorphologically. Autoimmune hepatitis serology such as anti-F-actin, anti-liver/kidney microsome, and hypergammaglobulinemia was negative in all patients. Five of 7 patients (71.4%) had, however, elevated antinuclear antibody, all with a speckled pattern. Hepatitis virus serology was negative in all patients. By immunohistochemical staining, the lobular CD8/CD4 lymphocyte ratio was markedly elevated in all of the initial samples with significant reduction in this ratio (P = 0.03) in 3 patients post treatment (ursodiol, antibiotics, and/or immunosuppressive therapy). Hepatitis preceding HAA is characterized by marked elevation of aminotransferases, conjugated hyperbilirubinemia, elevated antinuclear antibody with a speckled pattern, cholestatic hepatitis with sinusoidal obstruction morphology, and CD8 dominant lobular infiltrates. The present study suggests HAA may result from cytotoxic T-cell-mediated sinusoidal endothelial and hepatocytic injury.

  15. [Mesenteric-cava shunt's results with autologous jugular vein graft in children with pre-sinusoidal portal hypertension].

    Science.gov (United States)

    Leal, N; López Santamaría, M; Gámez, M; Murcia, J; Andolfi, G; Berrocal, T; Frauca, E; Jara, P; Tovar, J

    2002-07-01

    Presinusoidal portal hypertension (PPH) in children evaluates without functional hepatic damage, and with the time, trends to compensate through the creation of spontaneous portosystemic shunts. Nevertheless, some patients suffer episodes of gastrointestinal bleeding (GIB) that because of its frequency or severity, force to propose the change of surgical treatment. To evaluate the results of the mesocaval shunt (MCS) with autologous jugular vein in children with PPH. Among the 32 children with PPH treated in our Hospital in the last 7 years, 10 had episodes of GIB that forced to perform a surgical shunt. The types of shunt were distal splenorenal in 3 patients and mesocaval in 7. These 7 cases are the material of this study. The origin of the PPH was a cavernomatosis transformation of the portal vein in 6 cases and a congenital hepatic fibrosis in 1. Before the surgery the average number of episodes of GIB was 9 (range 2-15); all the patients needed transfusion of blood products and variceal sclerosis. In 2 cases a tamponade with the Sengtaken balloon was required and 5 patients were treated with somatostatin and propranolol. The Doppler ultrasounds revealed and intense hepatofugal collateral circulation in all the cases. The initial flow through the shunt was adequate in all the patients except one who required a percutaneous balloon dilatation. Only this patient has suffered an episode of GIB. The hyperesplenism signs disappeared or improved in all the seven cases and the collateral circulation was significantly reduced. The pressure in the splenic territory decreased around 50% in the 4 patients that was measured. There were no cases of encephalopasty and only one child with congenital hepatic fibrosis shows signs of mild hepatic disfunction. The medium follow up post-shunt is 32 months (range 8 m-6 years). The MCS prevents the GIB in the PPH not responsive to the conservative treatment; its effectiveness is related with an adequate permeability though the graft

  16. Evaluation of coronary artery bypass grafts with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okamura, Yoshitaka; Yamada, Yasuyuki; Mochizuki, Yoshihiko; Iida, Hiroshi; Mori, Hideaki; Sugita, You-ichi; Shimada, Kou-ichirou

    1997-01-01

    Currently, the efficacy of magnetic resonance imaging (MRI) for evaluating coronary artery disease has been reported. In this study, we have evaluated the usefulness and the problems of MRI for evaluating the patency of coronary artery bypass grafts. Thirty-five patients who received coronary artery bypass grafting (CABG) were evaluated by using MRI for determining the graft patency compared with conventional coronary angiography. There were 30 men and 5 women. The mean age was 61.2 years (range 45 to 75). The 35 patients had a total of 92 grafts (28 internal thoracic artery, 7 gastroepiploic artery and 57 saphenous vein grafts). Magnetic resonance coronary angiogram (MRCA) was performed with SIGNA HORIZON 1.5 T (GE Inc.) by using 2D-FASTCARD sequence. All patients underwent imaging in the transverse and coronal planes, most had imaging in the sagittal plane, and a few had in the oblique plane. By using MRCA, 82 of 90 grafts were diagnosed correctly as patent, and 1 of 2 grafts were diagnosed correctly as occluded. Thirty-four of 40 LAD grafts (85%), 20 of 22 RCA grafts (91%) and 29 of 30 Cx grafts (97%) were correctly evaluated. The efficacy of MRCA for evaluating the patency of coronary artery bypass grafts was recognized. But the sternal wire (stainless steel) and hemoclip interfere with the interpretation and reduce the sensitivity. Higher sensitivity may be obtained by changing the material of the sternal wires and hemoclips at coronary surgery. (author)

  17. Industrial application of electron beams for grafting and vulcanization

    Energy Technology Data Exchange (ETDEWEB)

    Makuuchi, Keizo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1994-12-31

    The topics discussed are radiation graft polymerization; industrial application of radiation grafting - ion exchange membrane for a battery separator, ammonia adsorbent, non-flammable PE (polyethylene) foam; R and D on radiation grafting, radiation vulcanization of natural rubber.

  18. Industrial application of electron beams for grafting and vulcanization

    International Nuclear Information System (INIS)

    Keizo Makuuchi

    1994-01-01

    The topics discussed are radiation graft polymerization; industrial application of radiation grafting - ion exchange membrane for a battery separator, ammonia adsorbent, non-flammable PE (polyethylene) foam; R and D on radiation grafting, radiation vulcanization of natural rubber

  19. [Skin graft, smoking and diabetes mellitus type 2].

    Science.gov (United States)

    Pérez-Guisado, Joaquín; Fidalgo-Rodríguez, Félix T; Gaston, Kate L; Rioja, Luis F; Thomas, Steven J

    2012-01-01

    Smoking and hyperglycemia decrease the success of skin graft survival in specific circumstances. It is well known that smoking and diabetes mellitus (DM) type 2 increase the oxidative and impair the endothelial function. The objective of this retrospective study was to determine if smoking and DM type 2 are factors associated with lower skin graft survival, in different etiologies of the injury associated to the skin loss. It was a bicentric, retrospective, cross sectional case control study, carried out on 2457 medical patients who met the inclusion criteria. It was carried out over a 10 years period between January 2000-December 2009, at Reina Sofía University Hospital (Córdoba, Spain) and UAB Hospital at Birmingham (Alabama, USA). The percentage of successful graft for each group and its control were analyzed by Chi-square test. The confidence interval chosen for statistical differences was 95%. Smoking and DM type 2 decreased the percentage of skin graft survival when compared with their control groups. DM type 2 was associated with greater negative success on skin graft survival than smoking when compared with their control groups. There was a statistically significant drop in skin graft of 18% in smoking group (range: 68-86%) and 25% in DM type 2 group (53-78%). The OR showed a clear association between the risk factors studied and the lower skin graft success, being stronger for DM type 2. In conclusion, DM type 2 and smoking are factors associated to lower skin graft take.

  20. Direct-acting Antivirals in Kidney Transplant Patients: Successful Hepatitis C Treatment and Short Term Reduction in Urinary Protein/Creatinine Ratios

    Directory of Open Access Journals (Sweden)

    Michael R. Goetsch

    2017-09-01

    Full Text Available Introduction: The role of Hepatitis C Virus (HCV clearance in long-term kidney graft survival is unknown. In this study, we examined short-term trends of urinary protein/creatinine (P/C ratios in a cohort of HCV-infected kidney transplant recipients with stable graft function and treated with direct-acting antivirals (DAAs. Methods: We conducted a retrospective study of 19 kidney transplant patients with chronic HCV infection treated with DAAs at the University of Alabama at Birmingham 1917 Viral Hepatitis Clinic between January 2013 and June 2016. Markers of glomerular damage were assessed using average protein/creatinine (P/C ratios measured pre- and post-treatment. We also described treatment efficacy using sustained virologic response at 12 weeks post-HCV treatment (SVR12. Results: The median age of the 19 patients included was 59 years (Q1=58, Q3=64 at completion of treatment. Of these patients, 68% were African American, 32% were White and 63% were male. The median time between kidney transplant and initiation of DAA therapy was 2.25 years (Q1=0.79, Q3=3.79. Post-treatment P/C ratios (median=0.127, Q1=0.090, Q3=0.220 were significantly lower (p=0.01 than pre-treatment ratios (median=0.168, Q1=0.118, Q3=0.385. P/C ratios decreased in 14 of 19 patients (74% with median change of -0.072 (median percent change= -40%. Post-treatment eGFRs (median=58.9, Q1=48.9, Q3=72.3 were not significantly different (p=0.82 than the pre-treatment values (median=57.0, Q1=48.8, Q3=67.8. Conclusions: In this preliminary study, there was a statistically significant decrease in P/C ratios associated with HCV clearance, suggesting a potential role for DAAs in improving kidney graft survival. Larger cohort studies will be needed to assess the clinical and long-term benefits of DAAs in this special population of HCV infected patients.

  1. A Study to Determine Susceptibility to Hepatitis A of Travelers from South Africa.

    Science.gov (United States)

    Waner; Schoub; Baxter; French

    1997-12-01

    Hepatitis A is an important cause of acute hepatitis in travelers to developing countries. In 1991, 33 million persons living in industrialized countries traveled to developing countries where hepatitis A is highly endemic (World Tourism Organization, unpublished data, 1993). Reports indicate that 40-50% of cases of hepatitis A infection in the United Kingdom,1 Switzerland2 and Sweden3 are associated with recent international travel. The disease is usually benign, but the severity increases with age.4 Because the disease is enterically transmitted, occurrence is related to water quality and level of sanitation. In developing countries, with poor water quality and sanitation, especially in the tropics where hepatitis A is endemic, exposure is virtually universal before the age of 10 years.4 In developed countries with good food and water hygiene, the rate of exposure to hepatitis A in children is low. The rate of seropositivity increases slowly during early adulthood and reaches moderate levels during late adulthood.5 Studies have demonstrated the higher prevalence among people who live in poor, overcrowded conditions.6 Travelers going from low incidence countries to endemic areas are particularly at risk for acquiring hepatitis A, especially if they stay for extended periods.7 The risk that Danish travelers to North Africa would acquire hepatitis A was estimated to be 3.5 per 10,000, and this population accounted for at least 20% of all cases of hepatitis in Denmark. Similarly, Germans traveling or living in tropical countries have a 40 times higher risk of acquiring hepatitis than do groups living at home.8 The pattern in South Africans ranges from minimal exposure to hepatitis A in childhood in populations with good water quality and sanitation (mainly white), to high exposure in those exposed to poor water quality and sanitation in childhood (mainly black). Hepatitis A vaccine has been found to be effective in reducing the incidence of infection in travelers

  2. Hepatitis C and the correctional population.

    Science.gov (United States)

    Reindollar, R W

    1999-12-27

    The hepatitis C epidemic has extended well into the correctional population where individuals predominantly originate from high-risk environments and have high-risk behaviors. Epidemiologic data estimate that 30% to 40% of the 1.8 million inmates in the United States are infected with the hepatitis C virus (HCV), the majority of whom were infected before incarceration. As in the general population, injection drug use accounts for the majority of HCV infections in this group--one to two thirds of inmates have a history of injection drug use before incarceration and continue to do so while in prison. Although correctional facilities also represent a high-risk environment for HCV infection because of a continued high incidence of drug use and high-risk sexual activities, available data indicate a low HCV seroconversion rate of 1.1 per 100 person-years in prison. Moreover, a high annual turnover rate means that many inmates return to their previous high-risk environments and behaviors that are conducive either to acquiring or spreading HCV. Despite a very high prevalence of HCV infection within the US correctional system, identification and treatment of at-risk individuals is inconsistent, at best. Variable access to correctional health-care resources, limited funding, high inmate turnover rates, and deficient follow-up care after release represent a few of the factors that confound HCV control and prevention in this group. Future efforts must focus on establishing an accurate knowledge base and implementing education, policies, and procedures for the prevention and treatment of hepatitis C in correctional populations.

  3. Grafting improves cucumber water stress tolerance in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulaziz R. Al-Harbi

    2018-02-01

    Full Text Available Water scarcity is a major limiting factor for crop productivity in arid and semi-arid areas. Grafting elite commercial cultivars onto selected vigorous rootstocks is considered as a useful strategy to alleviate the impact of environmental stresses. This study aims to investigate the feasibility of using grafting to improve fruit yield and quality of cucumber under water stress conditions. Alosama F1 cucumber cultivar (Cucumis sativus L. was grafted onto Affyne (Cucumis sativus L. and Shintoza A90 (Cucurbitamaxima × C. moschata rootstocks. Non-grafted plants were used as control. All genotypes were grown under three surface drip irrigation regimes: 50%, 75% and 100% of the crop evapotranspiration (ETc, which represent high-water stress, moderate-water stress and non-water stress conditions, respectively. Yield and fruit quality traits were analyzed and assessed. In comparison to the non-grafted plants, the best grafting treatment under water stress was Alosama F1 grafted onto Shintoza A90 rootstock. It had an overall improved yield and fruit quality under water stress owing to an increase in the total fruit yield by 27%, from 4.815 kg plant−1 in non-grafted treatment to 6.149 kg plant−1 in grafted treatment under moderate -water stress, total soluble solid contents (13%, titratable acidity (39% and vitamin C (33%. The soil water contents were low in soil surface and increase gradually with soil depth, while salt distribution showed an adverse trend. The positive effects of grafting on plant growth, productivity, and water use efficiency support this strategy as an useful tool for improving water stress tolerance in greenhouse grown cucumber in Saudi Arabia.

  4. Bacterial adherence to vascular grafts after in vitro bacteremia

    International Nuclear Information System (INIS)

    Rosenman, J.E.; Pearce, W.H.; Kempczinski, R.F.

    1985-01-01

    All currently used arterial prosthetics have a greater susceptibility to infection following bacteremia than does autogenous tissue. This experiment compares quantitative bacterial adherence to various prosthetic materials after bacteremia carried out in a tightly controlled and quantitative fashion. Ten centimeters long, 4 mm i.d. Dacron, umbilical vein (HUV), and polytetrafluoroethylene (PTFE) grafts, as well as PTFE grafts with a running suture line at the midportion were tested. Each graft was interposed into a pulsatile perfusion system modified from a Waters MOX 100 TM renal transplant pump. Indium-111-labeled Staphylococcus aureus were added to heparinized canine blood to give a mean concentration of 4.7 X 10(6) bacteria/cc. This infected blood was recirculated through each graft for 30 min at a rate of 125 cc/m, 100 Torr (sys), 60 beats/min. The gamma counts/graft were used to calculate the number of bacteria/cm2 of graft surface. After nine experiments, a mean of 9.63 X 10(5) bacteria/cm2 were adherent to the Dacron, 1.04 X 10(5) bacteria/cm2 to the HUV, and 2.15 X 10(4) bacteria/cm2 to the PTFE. These differences were all significant at the 0.05 level. The addition of a suture line increased bacterial adherence to the PTFE graft by 50%. These results suggest that PTFE is the vascular graft material of choice when a prosthetic graft must be implanted despite a high risk of subsequent clinical bacteremia. An in vitro, pulsatile perfusion model gave accurate and reproducible results, and appears well suited for further studies of bacterial, or platelet adherence to grafts, as well as the biomechanics of vascular conduits

  5. Grafting improves cucumber water stress tolerance in Saudi Arabia.

    Science.gov (United States)

    Al-Harbi, Abdulaziz R; Al-Omran, Abdulrasoul M; Alharbi, Khadiga

    2018-02-01

    Water scarcity is a major limiting factor for crop productivity in arid and semi-arid areas. Grafting elite commercial cultivars onto selected vigorous rootstocks is considered as a useful strategy to alleviate the impact of environmental stresses. This study aims to investigate the feasibility of using grafting to improve fruit yield and quality of cucumber under water stress conditions. Alosama F 1 cucumber cultivar ( Cucumis sativus L.) was grafted onto Affyne ( Cucumis sativus L.) and Shintoza A90 ( Cucurbitamaxima × C. moschata ) rootstocks. Non-grafted plants were used as control. All genotypes were grown under three surface drip irrigation regimes: 50%, 75% and 100% of the crop evapotranspiration (ETc), which represent high-water stress, moderate-water stress and non-water stress conditions, respectively. Yield and fruit quality traits were analyzed and assessed. In comparison to the non-grafted plants, the best grafting treatment under water stress was Alosama F 1 grafted onto Shintoza A90 rootstock. It had an overall improved yield and fruit quality under water stress owing to an increase in the total fruit yield by 27%, from 4.815 kg plant -1 in non-grafted treatment to 6.149 kg plant -1 in grafted treatment under moderate -water stress, total soluble solid contents (13%), titratable acidity (39%) and vitamin C (33%). The soil water contents were low in soil surface and increase gradually with soil depth, while salt distribution showed an adverse trend. The positive effects of grafting on plant growth, productivity, and water use efficiency support this strategy as an useful tool for improving water stress tolerance in greenhouse grown cucumber in Saudi Arabia.

  6. Identification of acute self-limited hepatitis B among patients presenting with hepatitis B virus-related acute hepatitis: a hospital-based epidemiological and clinical study.

    Science.gov (United States)

    Han, Y-N

    2009-01-01

    This study aimed to identify acute self-limited hepatitis B (ASL-HB) among patients presenting with hepatitis B virus (HBV)-related acute hepatitis. Data were available for 220 patients diagnosed with HBV-related acute hepatitis, of whom 164 had acute hepatitis B (AHB). Of these, 160 were confirmed as ASL-HB: three (1.9%) evolved to chronic hepatitis B and one (0.6%) developed fulminant hepatitis and died. Comparisons were also made between AHB and acute infections with hepatitis A (HA) and hepatitis E (HE) viruses. During the study period, the number of patients with AHB exceeded the sum of those with acute HA and acute HE infections. There was no distinct seasonal peak for AHB infection, whereas both acute HA and acute HE infections occurred more frequently in the spring. Clinical symptoms and physical signs were similar for all three types of hepatitis, but significant differences were seen in some biochemical parameters. In conclusion, this study suggests that symptomatic AHB is not rare in China but it seldom evolves to chronic hepatitis B.

  7. Crystallization of calcium carbonate on radiation-grafted polyethylene films

    International Nuclear Information System (INIS)

    Hou Zhengchi; Zhang Fengying; Deng Bo; Yang Haijun; Chen Shuang; Sheng Kanglong

    2006-01-01

    In biomineralization processes, nucleation and growth of inorganic crystals can be regulated by organic template molecules. This has inspired great interest in studying mimic biomineralization. In our study, growing CaCO 3 crystals on PE films functionalized through radiation-induced grafting was attempted. PE films grafted with different functional groups of different distributions and densities were used as substrates for CaCO 3 nucleation and crystal growth from Ca(HCO 3 ) 2 supersaturated solution under different environmental conditions (e.g. additives and temperature) to study the effects and mechanisms. The grafted PE films were analyzed by ATR-FTIR and AFM, and the evolution of CaCO 3 crystal formation on the grafted PE film was characterized by SEM, FTIR, and XRD. The results indicated that heterogeneous nucleation of CaCO 3 crystals was significantly facilitated by the functional groups grafted on the surface of PE films, that the morphology of CaCO 3 crystals could be controlled by distribution and density of the grafted functional groups, and that polymorphism of CaCO 3 crystal could be regulated by selection of grafting functional groups. We believe that studying the effects of chemical structures on inorganic crystallization is of great importance since radiation-induced grafting is an effective method to graft desirable functional groups onto different polymers by selected monomers, in the endeavor of developing advanced organic/inorganic composites with high performance, with a wide availability of polymers, monomers and inorganic solutions. (authors)

  8. Rapid synthesis of graft copolymers from natural cellulose fibers.

    Science.gov (United States)

    Thakur, Vijay Kumar; Thakur, Manju Kumari; Gupta, Raju Kumar

    2013-10-15

    Cellulose is the most abundant natural polysaccharide polymer, which is used as such or its derivatives in a number of advanced applications, such as in paper, packaging, biosorption, and biomedical. In present communication, in an effort to develop a proficient way to rapidly synthesize poly(methyl acrylate)-graft-cellulose (PMA-g-cellulose) copolymers, rapid graft copolymerization synthesis was carried out under microwave conditions using ferrous ammonium sulfate-potassium per sulfate (FAS-KPS) as redox initiator. Different reaction parameters such as microwave radiation power, ratio of monomer, solvent and initiator concentrations were optimized to get the highest percentage of grafting. Grafting percentage was found to increase with increase in microwave power up to 70%, and maximum 36.73% grafting was obtained after optimization of all parameters. Fourier transforms infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and thermogravimetric analysis (TGA/DTA/DTG) analysis were used to confirm the graft copolymerization of poly(methyl acrylate) (PMA) onto the mercerized cellulose. The grafted cellulosic polymers were subsequently subjected to the evaluation of different physico-chemical properties in order to access their application in everyday life, in a direction toward green environment. The grafted copolymers demonstrated increased chemical resistance, and higher thermal stability. Published by Elsevier Ltd.

  9. The impact of slow graft function on graft outcome is comparable to delayed graft function in deceased donor kidney transplantation.

    Science.gov (United States)

    Shin, Jung-Ho; Koo, Eun Hee; Ha, Sung Hae; Park, Ji Hyeon; Jang, Hye Ryoun; Lee, Jung Eun; Park, Jae-Berm; Kim, Sung Joo; Jung, Sin-Ho; Kim, Yoon-Goo; Kim, Dae Joong; Oh, Ha Young; Huh, Wooseong

    2016-03-01

    Slow graft function (SGF) can influence overall prognosis in patients receiving deceased donor kidney transplantation (DKT). However, the impact of SGF on renal function remains uncertain. We investigated retrospectively renal function in cases with SGF compared with early graft function (EGF) and delayed graft function (DGF). Renal function after transplantation was analyzed in 199 patients who underwent DKT. Patients were classified into 130 (65.3 %) cases with EGF, 27 (13.6 %) cases with SGF, 6 (3.0 %) cases with DGF and one dialysis (DGF1), and 36 (18.1 %) cases with DGF and two or more dialyses (DGF2). The 1-year estimated glomerular filtration rate (eGFR) in the SGF group was lower than that in the EGF group (P = 0.027), but the rate of eGFR decline did not differ between the groups. The risk factors for renal function were evaluated using the area under the eGFR curve over 3 years (AUCeGFR). Donor age was negatively, and recipient age and the number of HLA matches were positively correlated with the AUCeGFR (all P DKT. Moreover, it was comparable to DGF. Efforts should be dedicated to minimizing the development of SGF and DGF.

  10. Mirizzi syndrome associated with hepatic artery pseudoaneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Anderson Oliver

    2008-11-01

    Full Text Available Abstract Introduction This is the first case report of Mirizzi syndrome associated with hepatic artery pseudoaneurysm. Case presentation A 54-year-old man presented with painful obstructive jaundice and weight loss. Computed tomography showed a hilar mass in the liver. Following an episode of haemobilia, angiography demonstrated a pseudoaneurysm of a branch of the right hepatic artery that was embolised. At surgery, a gallstone causing Mirizzi type II syndrome was found to be responsible for the biliary obstruction and a necrotic inflammatory mass and haematoma were found to be extending into the liver. The mass was debrided and drained, the obstructing stones removed and the bile duct drained with a t-tube. The patient made a full recovery. Conclusion This case highlights another situation where there may be difficulty in differentiating Mirizzi syndrome from biliary tract cancer.

  11. Chrysanthemum cutting productivity and rooting ability are improved by grafting.

    Science.gov (United States)

    Zhang, Jing; Chen, Sumei; Liu, Ruixia; Jiang, Jiafu; Chen, Fadi; Fang, Weimin

    2013-01-01

    Chrysanthemum has been commercially propagated by rooting of cuttings, whereas the quality will decline over multiple collections from a single plant. Therefore, we compared the vigour, rooting ability, and some physiological parameters between cuttings harvested from nongrafted "Jinba" (non-grafted cuttings) with those collected from grafted "Jinba" plants onto Artemisia scoparia as a rootstock (grafted cuttings). The yield, length, node number, stem diameter, fresh weight, and dry weight of the grafted cuttings were superior to the non-grafted cuttings. Also grafted cuttings "Jinba" rooted 1 day earlier, but showing enhanced rooting quality including number, length, diameter, and dry weight of roots, where compared to the non-grafted. The physiological parameters that indicated contents of soluble protein, peroxidase activity, soluble sugar, and starch, ratios of soluble sugar/nitrogen ratio, and carbohydrate/nitrogen (C/N), as well as contents of indole-3-acetic acid (IAA) and abscisic acid (ABA), and IAA/ABA ratio were significantly increased in the grafted cuttings. This suggested their important parts in mediating rooting ability. Results from this study showed that grafting improved productivity and rooting ability related to an altered physiology, which provide a means to meet the increasing demand.

  12. Study on radiation grafting reaction of MMA onto hydroxyapatite

    International Nuclear Information System (INIS)

    Jiang Bo

    1996-01-01

    The grafting reaction of MMA onto hydroxyapatite has been studied with the pre-irradiation method in air. The effects of radiation dose, monomer concentration, reaction temperature and inorganic acid on the system are observed. The grafting copolymerization is found to be controlled by the kinetics. If proper kinetic conditions are selected, a better grafting yield can be obtained. Employing weight method, burning method as well as SeM and IR analysis, it has been proved that MMA is definitely grafted onto hydroxyapatite by chemical bonds, which shows that it is possible to improve the interface of inorganic-organic composite materials and to make bioactive ceramics by using radiation induced-grafting copolymerization

  13. HIV and Viral Hepatitis

    Science.gov (United States)

    ... common causes of viral hepatitis are hepatitis A virus (HAV), hepatitis B virus (HBV), and hepatitis C virus (HCV). HBV and HCV are common ... gov/ mmwr/ preview/ mmwrhtml/ rr5516a1. htm? s_ cid= rr5516a1_ e. The Numbers • • Of people with HIV in the ...

  14. Recurrent paratyphoid fever A co-infected with hepatitis A reactivated chronic hepatitis B.

    Science.gov (United States)

    Liu, Yanling; Xiong, Yujiao; Huang, Wenxiang; Jia, Bei

    2014-05-12

    We report here a case of recurrent paratyphoid fever A with hepatitis A co-infection in a patient with chronic hepatitis B. A 26-year-old male patient, who was a hepatitis B virus carrier, was co-infected with Salmonella enterica serovar Paratyphi A and hepatitis A virus. The recurrence of the paratyphoid fever may be ascribed to the coexistence of hepatitis B, a course of ceftriaxone plus levofloxacin that was too short and the insensitivity of paratyphoid fever A to levofloxacin. We find that an adequate course and dose of ceftriaxone is a better strategy for treating paratyphoid fever. Furthermore, the co-infection of paratyphoid fever with hepatitis A may stimulate cellular immunity and break immunotolerance. Thus, the administration of the anti-viral agent entecavir may greatly improve the prognosis of this patient with chronic hepatitis B, and the episodes of paratyphoid fever and hepatitis A infection prompt the use of timely antiviral therapy.

  15. Albumin grafting on biomaterial surfaces using gamma-irradiation

    International Nuclear Information System (INIS)

    Kamath, K.R.

    1993-01-01

    Surface modification has been used extensively in various fields to introduce desirable surface properties without affecting the bulk properties of the material. In the area of biomaterials, the approach of surface modification offers an effective alternative to the synthesis of new biomaterials. The specific objective of this study was to modify different biomaterial surfaces by albumin grafting to improve their blood compatibility. The modified surfaces were characterized for surface-induced platelet activation and thrombus formation. This behavior was correlated with the conditions used for grafting. In particular, albumin was functionalized to introduce pendant double bonds into the molecule. The functionalized albumin was covalently attached to various surfaces, such as dimethyldichlorosilane-coated glass, polypropylene, polycarbonate, poly(vinyl chloride), and polyethylene by gamma-irradiation. Platelet adhesion and activation on these surfaces was examined using video microscopy and scanning electron microscopy. The extent of grafting was found to be dependent on the albumin concentration used for adsorption and the gamma-irradiation time. Release of the grafted albumin during exposure to blood was minimal. The albumin-grafted fibers maintained their thromboresistant properties even after storage at elevated temperatures for prolonged time periods. Finally, the approach was used to graft albumin on the PLEXUS Adult Hollow Fiber Oxygenators (Shiley). The blood compatibility of the grafted oxygenators improved significantly when compared to controls

  16. Insolubilisation of biologically active materials with novel radiation graft copolymers

    International Nuclear Information System (INIS)

    Garnett, J.L.; Jankiewicz, S.V.; Levot, R.; Sangster, D.F.

    1984-01-01

    The use of radiation grafting to immobilise a typical enzyme, trypsin, is reported. The technique involves radiation grafting to a backbone polymer a monomer containing an appropriate functional group to which the enzyme is bonded. In the present work, p-nitrostyrene has been grafted to representative trunk polymers, polypropylene and PVC, the nitro group in the resulting copolymer converted to the isothiocyanato derivative to which trypsin is attached. Of importance to this insolubilisation process, especially for radiation sensitive backbone polymers, is the inclusion of additives which enhance grafting. A new class of additives which increase the grafting yields is reported using as representative backbone polymers, naturally occurring cellulose and synthetic low density polyethylene. The new additives are specific metal salts such as LiClO 4 . The reactivity of these salts in grafting enhancement has been compared with that of mineral acid which has previously been used as an additive to increase grafting yields in both preirradiation and simultaneous techniques. A new model for grafting enhancement in the presence of the metal salts as well as acids is proposed whereby increased grafting yields are attributed to increased partitioning of monomer into the graft region in the presence of ionic solutes. The value of these additives in preparing copolymers suitable for general reagent insolubilisation reactions is discussed

  17. Five-year outcomes following a randomized trial of femorofemoral and femoropopliteal bypass grafting with heparin-bonded or standard polytetrafluoroethylene grafts

    DEFF Research Database (Denmark)

    Lindholt, Jes S.; Houlind, K.; Gottschalksen, B

    2016-01-01

    BACKGROUND: Cohort studies suggest superior long-term patency of luminal heparin-bonded polytetrafluoroethylene (Hb-PTFE) bypass grafts compared with standard PTFE grafts. The aim of this study was to compare the outcomes of Hb-PTFE grafts with those of standard PTFE grafts 5 years after...... a randomized trial. METHODS: Patients with intermittent claudication or critical limb ischaemia requiring femorofemoral or femoropopliteal bypass grafting were randomized in a clinical trial of Hb-PTFE versus standard PTFE in 11 Scandinavian centres between 2005 and 2009. Patients were followed up for 5 years...... of the primary outcome. Use of Hb-PTFE significantly improved patency by 37 per cent at 2 years, but 5 years after randomization there was no difference in primary patency (adjusted hazard ratio (HR) 0·95, 95 per cent c.i. 0·71 to 1·28; P = 0·748). In patients with critical limb ischaemia the use of Hb-PTFE...

  18. Enhanced binding by dextran-grafting to Protein A affinity chromatographic media.

    Science.gov (United States)

    Zhao, Lan; Zhu, Kai; Huang, Yongdong; Li, Qiang; Li, Xiunan; Zhang, Rongyue; Su, Zhiguo; Wang, Qibao; Ma, Guanghui

    2017-04-01

    Dextran-grafted Protein A affinity chromatographic medium was prepared by grafting dextran to agarose-based matrix, followed by epoxy-activation and Protein A coupling site-directed to sulfhydryl groups of cysteine molecules. An enhancement of both the binding performance and the stability was achieved for this dextran-grafted Protein A chromatographic medium. Its dynamic binding capacity was 61 mg immunoglobulin G/mL suction-dried gel, increased by 24% compared with that of the non-grafted medium. The binding capacity of dextran-grafted medium decreased about 7% after 40 cleaning-in-place cycles, much lower than that of the non-grafted medium as decreased about 15%. Confocal laser scanning microscopy results showed that immunoglobulin G was bound to both the outside and the inside of dextran-grafted medium faster than that of non-grafted one. Atomic force microscopy showed that this dextran-grafted Protein A medium had much rougher surface with a vertical coordinate range of ±80 nm, while that of non-grafted one was ±10 nm. Grafted dextran provided a more stereo surface morphology and immunoglobulin G molecules were more easily to be bound. This high-performance dextran-grafted Protein A affinity chromatographic medium has promising applications in large-scale antibody purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Late-Onset Hepatic Veno-Occlusive Disease after Allografting: Report of Two Cases with Atypical Clinical Features Successfully Treated with Defibrotide.

    Science.gov (United States)

    Castellino, Alessia; Guidi, Stefano; Dellacasa, Chiara Maria; Gozzini, Antonella; Donnini, Irene; Nozzoli, Chiara; Manetta, Sara; Aydin, Semra; Giaccone, Luisa; Festuccia, Moreno; Brunello, Lucia; Maffini, Enrico; Bruno, Benedetto; David, Ezio; Busca, Alessandro

    2018-01-01

    Hepatic Veno-Occlusive Disease (VOD) is a potentially severe complication of hematopoietic stem cell transplantation (HSCT). Here we report two patients receiving an allogeneic HSCT who developed late onset VOD with atypical clinical features. The two patients presented with only few risk factors, namely, advanced acute leukemia, a myeloablative busulphan-containing regimen and received grafts from an unrelated donor. The first patient did not experience painful hepatomegaly and weight gain and both patients showed only a mild elevation in total serum bilirubin level. Most importantly, the two patients developed clinical signs beyond day 21 post-HSCT. Hepatic transjugular biopsy confirmed the diagnosis of VOD. Intravenous defibrotide was promptly started leading to a marked clinical improvement. Based on our experience, liver biopsy may represent a useful diagnostic tool when the clinical features of VOD are ambiguous. Early therapeutic intervention with defibrotide represents a crucial issue for the successful outcome of patients with VOD.

  20. Late-onset hepatic veno-occlusive disease after allografting: report of two cases with atypical clinical features successfully treated with defibrotide.

    Directory of Open Access Journals (Sweden)

    Alessia Castellino

    2018-01-01

    Full Text Available Hepatic Veno-occlusive disease (VOD is a potentially severe complication of hematopoietic stem cell transplantation (HSCT. Here we report two patients receiving an allogeneic HSCT  who developed late onset VOD with atypical clinical features. The two  patients presented with only few risk factors, namely, advanced acute leukemia, a myeloablative busulphan-containing regimen and received grafts from an unrelated donor. The first patient did not experience painful hepatomegaly and weight gain and both  patients showed only a mild elevation in total serum bilirubin level. Most importantly, the two patients developed clinical signs beyond day 21 post-HSCT. Hepatic transjugular biopsy confirmed the diagnosis of VOD. Intravenous defibrotide was promptly started leading to a marked clinical improvement. Based on our experience, liver biopsy may represent a useful diagnostic tool when the clinical features of VOD are ambiguous. Early therapeutic intervention with defibrotide  represents a crucial issue for the successful outcome of patients with VOD.

  1. Radiation-induced grafting of acrylic acid onto polypropylene film and its biodegradability

    Science.gov (United States)

    Mandal, Dev K.; Bhunia, Haripada; Bajpai, Pramod K.; Chaudhari, C. V.; Dubey, K. A.; Varshney, L.

    2016-06-01

    Polypropylene based commodity polyolefins are widely used in packaging, manufacturing, electrical, pharmaceutical and other applications. The aim of the present work is to study the effect of grafting of acrylic acid on the biodegradability of acrylic acid grafted polypropylene. The effect of different conditions showed that grafting percentage increased with increase in monomer concentration, radiation dose and inhibitor concentration but decreased with increase in radiation dose rate. The maximum grafting of 159.4% could be achieved at optimum conditions. The structure of grafted polypropylene films at different degree of grafting was characterized by EDS, FTIR, TGA, DSC, SEM and XRD. EDS studies showed that the increase in acrylic acid grafting percentage increased the hydrophilicity of the grafted films. FTIR studies indicated the presence of acrylic acid on the surface of polypropylene film. TGA studies revealed that thermal stability decreased with increase in grafting percentage. DSC studies showed that melting temperature and crystallinity of the grafted polypropylene films lower than polypropylene film. SEM studies indicated that increase in acrylic acid grafting percentage increased the wrinkles in the grafted films. The maximum biodegradability could be achieved to 6.85% for 90.5% grafting. This suggested that microorganisms present in the compost could biodegrade acrylic acid grafted polypropylene.

  2. Detection of occult hepatitis B virus among chronic hepatitis C patients

    African Journals Online (AJOL)

    Background: Concurrent infections with hepatitis B virus (HBV) and hepatitis C virus (HCV) are increasingly recognized in patients with chronic hepatitis. In Egypt, the last decade showed a remarkable decline in HBV infection associated with remarkable rise in HCV infection. The probable impact of occult HBV in patients ...

  3. Evaluation of aortocoronary bypass graft patency by reconstructed CT image

    International Nuclear Information System (INIS)

    Kawakita, Seizaburo; Koide, Takashi; Saito, Yoshio; Yamamoto, Tadao; Iwasaki, Tadaaki

    1982-01-01

    Ten patients were examined in the period of three months from January to March 1981. The patients were operated from 1 month to 7 years before CT. A bypass to the left anterior descending artery (LAD) was grafted in 10 cases, 2 to the right coronary artery (RCA), 4 to an obtuse marginal artery (OM), and 1 to a diagonal artery. Image reconstruction was performed in 10 cases by using an image analytical computer Evaluskop. Appropriate planes for reconstruction were selected by trial and error methods upon observation of CT images. When gained picture of a graft course coincided with surgical records or angiography, the work of building images was concluded. On cross section, grafts to LAD were visualized in all 10 cases: 9 in the entire course and 1 in a proximal part of the graft. Two to RCA, 4 to OM and 1 to a diagonal were also successfully visualized. Reconstruction of graft images succeeded in 9 grafts of 6 cases. The course of a graft could be pursued from the proximal to the distal end adjacent to the cardiac chamber. The picture of a bypass to LAD was visualized in 6 of 10 grafts. Two bypass to RCA could be depicted, and 1 to OM was also found. However 3 to OM and 1 to a diagonal failed to be visualized throughout their courses in reconstructed images. I think that the causes of faillure mainly depended upon the course of the graft. When a graft was running arc-like surrounding the heart chamber, it was very difficult to depict its entire length in reconstructed images, though the graft could be detected in cross sections. These preliminary studies indicated that reconstruction of CT images had some benefits for the pursuit of graft courses. (J.P.N.)

  4. Inverse cutting of posterior lamellar corneal grafts by a femtosecond laser.

    Science.gov (United States)

    Hjortdal, Jesper; Nielsen, Esben; Vestergaard, Anders; Søndergaard, Anders

    2012-01-01

    Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft thickness towards the periphery in every graft. The purpose of this study was to evaluate if posterior lamellar grafts can be prepared from the endothelial side by a femto-second laser, resulting in reproducible, thin grafts of even thickness. A CZM 500 kHz Visumax femto-second laser was used. Organ cultured donor grafts were mounted in an artifical anterior chamber with the endothelial side up and out. Posterior grafts of 7.8 mm diameter and 130 micron thickness were prepared by femto-second laser cutting. A standard DSAEK procedure was performed in 10 patients with Fuchs endothelial dystrophy. Patients were followed-up regularly and evaluated by measurement of complications, visual acuity, corneal thickness (Pentacam HR), and endothelial cell density. Femto-laser cutting of grafts and surgery was uncomplicated. Rebubbling was necessary in 5 of 10 cases (normally only in 1 of 20 cases). All grafts were attached and cleared up during the first few weeks. After six months, the average visual acuity was 0.30 (range: 0.16 to 0.50), corneal thickness was 0.58 mm (range 0.51 to 0.63), and endothelial cell density was 1.570 per sq. mm (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months with satisfying endothelial cell counts. Poor visual acuity caused by interface scatter was observed in most patients. Femto-second laser cutting parameters needs to be optimised to

  5. Hepatitis viruses overview

    African Journals Online (AJOL)

    Hepatitis is major cause of morbidity or mortality worldwide, particularly in the developing world. The major causes of infective hepatitis are hepatitis viruses. A, B, C, D or E. In the acute phase, there are no clinical features that can reliably differentiate between these viruses. Infection may be asymptomatic or can present as.

  6. Breeding graft-compatible Douglas-fir rootstocks (Pseudotsuga menziesii (Mirb.) Franco).

    Science.gov (United States)

    D.L. Copes

    1999-01-01

    A study encompassing 24 years was conducted to determine if a breeding program could produce highly graft-compatible rootstocks. Twenty-seven trees of apparent high graft compatibility were selected and crossed to produce 226 control-pollinated families. Seedlings were grown, field planted, and grafted with test scions. Graft unions from field tests were evaluated...

  7. Fingertip Replantation Using Y-Shaped Vein Graft to Pulp Artery.

    Science.gov (United States)

    Kim, Jun Hyuk; Lee, Young Man

    2015-10-01

    Re-establishing adequate venous outflow is the most important factor for success of fingertip replantation. However, in zone I level, replantation is very difficult, especially in repairing venous circulation. The authors have made an attempt to replantation using Y-shaped vein (YSV) graft to identify and repair veins easily in fingertip replantation. From January 2007 to December 2012, a total of 46 fingertip replantations in 44 consecutive patients with amputations in the Tamai zone I level were performed by using YSV graft. In all patients, arterial anastomosis was performed using YSV graft, and interpositional vein grafts were used for venous repair. The overall success rate of the YSV-grafted replantations was 91.3% (42/46). Postoperative vascular complications occurred in 6 YSV-grafted replantations (13%), and pulp atrophy in the YSV-grafted digits was 9.5% (4/42). Fingertip replantation in zone I level is a difficult territory to a microsurgeon, especially anastomosing veins. However, our YSV grafting technique has shown value in this setting, enabling better esthetic and functional results.

  8. Characterization of Functionalized Acrylic acid /4- Vinyl Pyridine Graft Copolymers

    International Nuclear Information System (INIS)

    Kamal, H.; Mahmoud, Gh.A.; Hegazy, D.E.

    2009-01-01

    Properties and characterization of the membranes prepared by radiation grafting of acrylic acid (AAc) or/ and 4-vinyl pyridine (4VP) onto low density polyethylene (LDPE) and polypropylene (PP) films were carried out. The FTIR spectra for the grafted membranes were studied to evaluate the structure change as a result of grafting. The swelling behaviour of the graft copolymer in methanol was studied. It was found that the grafting of AAc and/ or 4- VP onto LDPE and PP resulted in introducing good hydrophilic properties to such polymer substrates. The hydrophilic properties were directly proportional to the amount of functional groups. The mechanical properties (Young's modulus, elongation percent and tensile strength) of the grafted membranes also, have been investigated. As the grafting degree increases, the modulus also increases. Increasing the hydrophilicity of the membranes by chemical treatment enhances its mechanical properties. The thermal parameters of the grafted membranes such as δH m1 . δH m2 , and T rc have been also studied by using DSC

  9. Cytocompatibility of amine functionalized carbon nanoparticles grafted on polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Žáková, Pavlína, E-mail: pavlina.zakova@vscht.cz [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague 6 (Czech Republic); Slepičková Kasálková, Nikola [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague 6 (Czech Republic); Kolská, Zdeňka [Faculty of Science, J. E. Purkyně University, Ústí nad Labem (Czech Republic); Leitner, Jindřich [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague 6 (Czech Republic); Karpíšková, Jana; Stibor, Ivan [Institute for Nanomaterials, Advanced Technologies and Innovation, Technical University of Liberec (Czech Republic); Slepička, Petr; Švorčík, Václav [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague 6 (Czech Republic)

    2016-03-01

    Five types of amide–amine Carbon Nano-Particles (CNPs) were prepared by functionalization of CNPs and characterized by several analytical methods. The successful grafting of amines on CNPs was verified by X-ray photoelectron spectroscopy (XPS), organic elemental analysis and electrokinetic analysis. The size and morphology of CNPs were determined from transmission electron microscopy. The surface area and porosity of CNPs were examined by adsorption and desorption isotherms. Differential scanning calorimetry was used to investigate thermal stability of CNPs. The amount of bonded amine depends on its dimensionality arrangement. Surface area and pore volumes of CNPs decrease several times after individual amino-compound grafting. Selected types of functionalized CNPs were grafted onto a plasma activated surface of HDPE. The successful grafting of CNPs on the polymer surface was verified by XPS. Wettability was determined by contact angle measurements. Surface morphology and roughness were studied by atomic force microscopy. A dramatic decrease of contact angle and surface morphology was observed on CNP grafted polymer surface. Cytocompatibility of modified surfaces was studied in vitro, by determination of adhesion, proliferation and viability of vascular smooth muscle cells (VSMCs). Grafting of CNPs onto the polymer surface has a positive effect on the adhesion, proliferation and viability of VSMCs. - Highlights: • Amine functionalized CNPs were successfully grafted on HDPE surface. • Significant change to the positive zeta potential for grafted CNPs was induced. • Grafting of CNPs significantly enhanced cell cytocompatibility and viability. • Homogeneous distribution of cells with correct size was achieved.

  10. Composite vascular repair grafts via micro-imprinting and electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yuanyuan, E-mail: yuanyuan-liu@shu.edu.cn; Hu, Qingxi, E-mail: huqingxi@shu.edu.cn [Rapid Manufacturing Engineering Center, Shanghai University, Shanghai 200444 (China); Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai 200072 (China); Xiang, Ke, E-mail: xiangke@shu.edu.cn; Chen, Haiping, E-mail: 519673062@qq.com; Li, Yu, E-mail: liyu@hpu.edu.cn [Rapid Manufacturing Engineering Center, Shanghai University, Shanghai 200444 (China)

    2015-04-15

    Composite vascular grafts formed by micro-imprinting and electrospinning exhibited improved mechanical properties relative to those formed by electrospinning alone. The three-layered composite grafts mimic the three-layered structure of natural blood vessels. The middle layer is made by micro-imprinting poly-p-dioxanone (PPDO), while the inner and outer layers are electrospun mixtures of chitosan and polyvinyl alcohol. The graft morphology is characterized with scanning electron microscopy. For constant graft thicknesses, the PPDO increases the mechanical strength. Cells cultivated on the vascular grafts adhere and proliferate better because of the natural, biological chitosan in the inner and outer layers. Overall, the composite scaffolds could be good candidates for blood vessel repair.

  11. Amniotic-fluid-derived mesenchymal stem cells overexpressing interleukin-1 receptor antagonist improve fulminant hepatic failure.

    Directory of Open Access Journals (Sweden)

    Yu-Bao Zheng

    Full Text Available Uncontrolled hepatic immunoactivation is regarded as the primary pathological mechanism of fulminant hepatic failure (FHF. The major acute-phase mediators associated with FHF, including IL-1β, IL-6, and TNF-α, impair the regeneration of liver cells and stem cell grafts. Amniotic-fluid-derived mesenchymal stem cells (AF-MSCs have the capacity, under specific conditions, to differentiate into hepatocytes. Interleukin-1-receptor antagonist (IL-1Ra plays an anti-inflammatory and anti-apoptotic role in acute and chronic inflammation, and has been used in many experimental and clinical applications. In the present study, we implanted IL-1Ra-expressing AF-MSCs into injured liver via the portal vein, using D-galactosamine-induced FHF in a rat model. IL-1Ra expression, hepatic injury, liver regeneration, cytokines (IL-1β, IL-6, and animal survival were assessed after cell transplantation. Our results showed that AF-MSCs over-expressing IL-1Ra prevented liver failure and reduced mortality in rats with FHF. These animals also exhibited improved liver function and increased survival rates after injection with these cells. Using green fluorescent protein as a marker, we demonstrated that the engrafted cells and their progeny were incorporated into injured livers and produced albumin. This study suggests that AF-MSCs genetically modified to over-express IL-1Ra can be implanted into the injured liver to provide a novel therapeutic approach to the treatment of FHF.

  12. Transcriptomic Analysis Provides Insights into Grafting Union Development in Pecan (Carya illinoinensis).

    Science.gov (United States)

    Mo, Zhenghai; Feng, Gang; Su, Wenchuan; Liu, Zhuangzhuang; Peng, Fangren

    2018-02-05

    Pecan ( Carya illinoinensis ), as a popular nut tree, has been widely planted in China in recent years. Grafting is an important technique for its cultivation. For a successful grafting, graft union development generally involves the formation of callus and vascular bundles at the graft union. To explore the molecular mechanism of graft union development, we applied high throughput RNA sequencing to investigate the transcriptomic profiles of graft union at four timepoints (0 days, 8 days, 15 days, and 30 days) during the pecan grafting process. After de novo assembly, 83,693 unigenes were obtained, and 40,069 of them were annotated. A total of 12,180 differentially expressed genes were identified between by grafting. Genes involved in hormone signaling, cell proliferation, xylem differentiation, cell elongation, secondary cell wall deposition, programmed cell death, and reactive oxygen species (ROS) scavenging showed significant differential expression during the graft union developmental process. In addition, we found that the content of auxin, cytokinin, and gibberellin were accumulated at the graft unions during the grafting process. These results will aid in our understanding of successful grafting in the future.

  13. VO x /SiO 2 Catalyst Prepared by Grafting VOCl 3 on Silica for Oxidative Dehydrogenation of Propane

    KAUST Repository

    Zhu, Haibo; Ould-Chikh, Samy; Dong, Hailin; Llorens, Isabelle; Saih, Youssef; Anjum, Dalaver H.; Hazemann, Jean Louis; Basset, Jean-Marie

    2015-01-01

    The VOx/SiO2 catalysts for oxidative dehydrogenation of propane were synthesized by a simple grafting method. The VOCl3 was first grafted at the surface of SiO2, which was dehydrated at different temperature (from 200 to 1000°C). The formed grafted complexes were then calcined in air, leading to the formation of VOx/SiO2 catalysts. The synthesized catalysts were characterized by nitrogen adsorption, SEM, Raman spectroscopy, temperature-programmed reduction, and extended X-ray absorption fine structure analysis. The SiO2 pretreatment temperature has an evident effect on the loading and dispersion of VOx on SiO2, which finally affects their catalytic performance. High SiO2 treatment temperature is beneficial to dispersing the vanadium oxide species at the SiO2 surface. These materials are efficient catalysts for the catalytic oxidative dehydrogenation of propane to propylene. The best selectivity to propylene is achieved on the VOx/SiO2-(1000) catalyst. The high selectivity and activity are well maintained for three days catalytic reaction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. VO x /SiO 2 Catalyst Prepared by Grafting VOCl 3 on Silica for Oxidative Dehydrogenation of Propane

    KAUST Repository

    Zhu, Haibo

    2015-09-07

    The VOx/SiO2 catalysts for oxidative dehydrogenation of propane were synthesized by a simple grafting method. The VOCl3 was first grafted at the surface of SiO2, which was dehydrated at different temperature (from 200 to 1000°C). The formed grafted complexes were then calcined in air, leading to the formation of VOx/SiO2 catalysts. The synthesized catalysts were characterized by nitrogen adsorption, SEM, Raman spectroscopy, temperature-programmed reduction, and extended X-ray absorption fine structure analysis. The SiO2 pretreatment temperature has an evident effect on the loading and dispersion of VOx on SiO2, which finally affects their catalytic performance. High SiO2 treatment temperature is beneficial to dispersing the vanadium oxide species at the SiO2 surface. These materials are efficient catalysts for the catalytic oxidative dehydrogenation of propane to propylene. The best selectivity to propylene is achieved on the VOx/SiO2-(1000) catalyst. The high selectivity and activity are well maintained for three days catalytic reaction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Bone allograft banking in South Australia.

    Science.gov (United States)

    Campbell, D G; Oakeshott, R D

    1995-12-01

    The South Australian Bone Bank had expanded to meet an increased demand for allograft bone. During a 5 year period from 1988 to 1992, 2361 allografts were harvested from 2146 living donors and 30 cadaveric donors. The allografts were screened by contemporary banking techniques which include a social history, donor serum tests for HIV-1, HIV-2, hepatitis B and C, syphilis serology, graft microbiology and histology. Grafts were irradiated with 25 kGy. The majority of grafts were used for arthroplasty or spinal surgery and 99 were used for tumour reconstruction. Of the donated grafts 336 were rejected by the bank. One donor was HIV-positive and two had false positive screens. There were seven donors with positive serology for hepatitis B, eight for hepatitis C and nine for syphilis. Twenty-seven grafts had positive cultures. Bone transplantation is the most frequent non-haematogenous allograft in South Australia and probably nationally. The low incidence of infectious viral disease in the donor population combined with an aggressive discard policy has ensured relative safety of the grafts. The frequency of graft rejection was similar to other bone banks but the incidence of HIV was lower.

  16. Hepatitis B Foundation Newsletter: B Informed

    Science.gov (United States)

    ... Clinical Trials Physician Directory HBV Meeting What Is Hepatitis B? What Is Hepatitis B? The ABCs of Viral Hepatitis Liver Cancer and Hepatitis B Hepatitis Delta Coinfection Hepatitis C Coinfection HIV/AIDS ...

  17. Dynamics of solvent-free grafted nanoparticles

    KAUST Repository

    Chremos, Alexandros

    2012-01-01

    The diffusivity and structural relaxation characteristics of oligomer-grafted nanoparticles have been investigated with simulations of a previously proposed coarse-grained model at atmospheric pressure. Solvent-free, polymer-grafted nanoparticles as well as grafted nanoparticles in a melt were compared to a reference system of bare (ungrafted) particles in a melt. Whereas longer chains lead to a larger hydrodynamic radius and lower relative diffusivity for grafted particles in a melt, bulk solvent-free nanoparticles with longer chains have higher relative diffusivities than their short chain counterparts. Solvent-free nanoparticles with short chains undergo a glass transition as indicated by a vanishing diffusivity, diverging structural relaxation time and the formation of body-centered-cubic-like order. Nanoparticles with longer chains exhibit a more gradual increase in the structural relaxation time with decreasing temperature and concomitantly increasing particle volume fraction. The diffusivity of the long chain nanoparticles exhibits a minimum at an intermediate temperature and volume fraction where the polymer brushes of neighboring particles overlap, but must stretch to fill the interparticle space. © 2012 American Institute of Physics.

  18. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Your Story Spread the Word Give While You Shop Contact Us Donate Now Hepatic Encephalopathy Back Hepatic ... Your Story Spread the Word Give While You Shop Contact Us Donate Now Help ALF Improve This ...

  19. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... Now Hepatic Encephalopathy Back Hepatic Encephalopathy is a brain disorder that develops in some individuals with liver ... is a condition that causes temporary worsening of brain function in people with advanced liver disease. When ...

  20. Radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate)

    International Nuclear Information System (INIS)

    Gonzalez Torres, Maykel; Rapado Paneque, Manuel; Paredes Zaldivar, Mayte; Altanes Valentin, Sonia; Barrera Gonzalez, Gisela

    2008-01-01

    The graft copolymer poly (3-hydroxybutyrate)-g- polyacrylamide [P (HB-g-AAm)] was synthesized by radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate). The study was conducted by the simultaneous irradiation method. The structure of [P (HB-g-AAm)] was identified by Fourier Transform Infrared (FTIR) spectroscopy. Thermal behavior of the graft copolymer was also studied by Thermal Gravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). From the results it was found that FTIR studies showed new signals (stretching -N-H) as strong evidence of grafting. The grafting degree was found to be 10 % and the thermodynamic parameter obtained from the DSC thermogram of plain PHB and the graft copolymer varied showing decrease in the material crystallinity and increase in the glass transition temperature. These results demonstrate that the radiation induced graft copolymerization reaction of acrylamide onto PHB was successively achieved. (Author)

  1. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  2. Additive effects in radiation grafting and curing

    International Nuclear Information System (INIS)

    Viengkhou, V.; Ng, L.

    1996-01-01

    Full text: Detailed studies on the accelerative effect of novel additives in radiation grafting and curing using acrylated monomer/oligomer systems have been performed in the presence of ionising radiation and UV as sources. Methyl methacrylate (MMA) is used as typical monomer for these grafting studies in the presence of the additives with model backbone polymers, cellulose and propropylene. Additives which have been found to accelerate these grafting processes are: mineral acid, occlusion compounds like urea, thermal initiators and photoinitiators as well as multifunctional monomers such as multifunctional acrylates. The results from irradiation with gamma rays have also been compared with irradiation from a 90W UV lamp. The role of the above additives in accelerating the analogous process of radiation curing has been investigated. Acrylated urethanes, epoxies and polyesters are used as oligomers together with acrylated monomers in this work with uv lamps of 300 watts/inch as radiation source. In the UV curing process bonding between film and substrate is usually due to physical forces. In the present work the presence of additives are shown to influence the occurrence of concurrent grafting during cure thus affecting the nature of the bonding of the cured film. The conditions under which concurrent grafting with UV can occur will be examined. A mechanism for accelerative effect of these additives in both grafting and curing processes has been proposed involving radiation effects and partitioning phenomena

  3. Striatal grafts in a rat model of Huntington's disease

    DEFF Research Database (Denmark)

    Guzman, R; Meyer, M; Lövblad, K O

    1999-01-01

    Survival and integration into the host brain of grafted tissue are crucial factors in neurotransplantation approaches. The present study explored the feasibility of using a clinical MR scanner to study striatal graft development in a rat model of Huntington's disease. Rat fetal lateral ganglionic...... time-points graft location could not be further verified. Measures for graft size and ventricle size obtained from MR images highly correlated with measures obtained from histologically processed sections (R = 0.8, P fetal rat lateral ganglionic...

  4. Target-like pigmentation after minipunch grafting in stable vitiligo

    Directory of Open Access Journals (Sweden)

    Nelee Bisen

    2014-01-01

    Full Text Available Surgical treatment for vitiligo has been ever evolving. Each surgical modality has its own benefits and limitations. Miniature punch grafting is the most extensively performed surgery, which gives good results in stable vitiligo. Herein we report an unusual type of repigmentation observed after minipunch grafting in a patient of stable vitiligo, which resembled target-like lesions with a "perigraft halo" surrounding individual grafts. Such pigment spread occurred despite the use of 0.5 mm larger graft from the donor site.

  5. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  6. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  7. Primary hepatic lymphoma presenting as fulminant hepatic failure with hyperferritinemia: A case report

    Directory of Open Access Journals (Sweden)

    Haider Fyeza S

    2008-08-01

    Full Text Available Abstract Introduction Primary hepatic lymphoma is an unusual form of non-Hodgkin's lymphoma that usually presents with constitutional symptoms, hepatomegaly and signs of cholestatic jaundice. Diffuse hepatic infiltration is uncommon and presentation with acute hepatic failure even more rare. The presence of markedly elevated ferritin levels can complicate the evaluation process and suggest alternative diagnoses. We present the case of a middle-aged woman exhibiting pancytopenia, hyperferritinemia and rapidly deteriorating to develop acute hepatic failure. Her initial clinical picture led to a working diagnosis of adult onset Still's disease with probable hemophagocytic syndrome before her worsening liver function necessitated a percutaneous liver biopsy and establishment of the final diagnosis of primary hepatic lymphoma. Conclusion Primary hepatic lymphoma is an uncommon malignancy and its manifestation as progressive hepatitis or acute fulminant hepatic failure can be difficult to diagnose. The presence of constitutional symptoms, pancytopenia and high ferritin levels can complicate the evaluation process. A liver biopsy early in the course of liver dysfunction may establish the diagnosis without a higher risk of bleeding complications seen once liver failure sets in.

  8. Bone formation in cranial, mandibular, tibial and iliac bone grafts in rats

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    1995-01-01

    Several studies have suggested that grafts from membranous derived bone (e.g., calvarial grafts) retain their volume better than those from endochondral derived bone (e.g., iliac bone grafts). Increased osteogenesis in grafts of the former type has been offered as the explanation. However, simple...... volume measurements of the recovered grafts do not differentiate between viable and dead bone. We studied fresh syngeneic full-thickness bone grafts from calvaria, mandibula, tibia diaphysis, and iliac bone implanted in the back muscles of young Lewis rats. Bone formation in grafts recovered 3 weeks...... that the anatomical area of harvest is important regarding new bone formation in syngeneic bone grafts. However, the results do not support the contention that better maintenance of volume of calvarial grafts compared with iliac bone grafts is due to enhanced osteogenesis in the former....

  9. Kidney graft recipients with pretransplantation HLA CLASS I antibodies and high soluble CD30 are at high risk for graft loss.

    Science.gov (United States)

    Rodríguez, Libia M; París, Sara C; Arbeláez, Mario; Cotes, José M; Süsal, Caner; Torres, Yolanda; García, Luís F

    2007-08-01

    In the present study, we investigated whether pretransplantation HLA class I and class II antibodies and pretransplantation levels of soluble CD30 (sCD30) and IgA anti-Fab autoantibodies are predictive of kidney allograft survival. Pretransplantation sera of 504 deceased-donor kidney recipients were tested for IgG HLA class I and class II antibodies, sCD30, and IgA anti-Fab levels using the CTS 4 ELISA kit. Kidney graft survival was estimated by Kaplan-Meier method and multivariate Cox regression. Regardless of the presence of HLA class II antibodies, recipients with high HLA class I reactivity had lower 1-year graft survival than recipients with low reactivity (p sCD30 had lower 5-year graft survival rate than those with low sCD30 (p sCD30 effect was observed in presensitized and nonsensitized recipients, demonstrated a synergistic effect with HLA class I antibodies (p kidney graft survival. Our results indicate that high pretransplantation sCD30 levels and HLA class I positivity increase the risk of kidney graft loss regardless of other factors. Consequently, such determinations should be routinely performed to estimate recipients' risks of graft rejection before transplantation.

  10. Treatment of Chronic Hepatitis C in a Canadian Aboriginal Population: Results from the Prairie Study

    Directory of Open Access Journals (Sweden)

    Gerald Yosel Minuk

    2013-01-01

    Full Text Available BACKGROUND: The Aboriginal population of Canada is at increased risk of exposure to the hepatitis C virus (HCV. Previous data indicate that spontaneous clearance of HCV occurs more often in Aboriginals than Caucasians. Whether this enhanced response extends to antiviral therapy for chronic HCV remains to be determined.

  11. Skin Graft Fixation Using Hydrofiber (Aquacel® Extra).

    Science.gov (United States)

    Yen, Ya-Hui; Lin, Chih-Ming; Hsu, Honda; Chen, Ying-Chen; Chen, Yi-Wen; Li, Wan-Yu; Hsieh, Chia-Nan; Huang, Chieh-Chi

    2018-06-01

    The traditional method of skin graft fixation is with tie-over bollus dressing. The use of splints in the extremities for skin graft fixation is a common practice. However, these splints are heavy and uncomfortable and contribute considerably to our overall medical waste. Hydrofiber (Aquacel Extra) has a strong fluid absorption property and fixates well to the underlying wound once applied. In this study, we used hydrofiber for fixation, avoiding the use of splints after skin grafting. A total of 56 patients reconstructed with split-thickness skin graft that was fixated only with hydrofiber between March 2015 and March 2016 were included in this retrospective study. There were 44 men and 12 women with a mean age of 61 ± 18 years. The defect size ranged from 1 × 1 cm for fingertips to 30 × 12 cm for lower limb defects. The average defect size was 61 ± 78 cm. The mean skin graft take was 96% ± 6%. Because splints were not required, we saved around 48 kg of medical waste over the space of 1 year. The use of hydrofiber for skin graft fixation was effective and technically very simple. Splints were not required with this method, decreasing the medical waste created and increasing patient comfort. We suggest that this is an excellent alternative for skin graft fixation while at the same time decreasing our carbon footprint as surgeons.

  12. Risk factors for and management of graft pancreatitis.

    Science.gov (United States)

    Nadalin, Silvio; Girotti, Paolo; Königsrainer, Alfred

    2013-02-01

    Systematic and detailed analysis of risk factors, pathophysiology, clinical manifestation, diagnosis and management of graft pancreatitis in its different forms, that is acute and chronic graft pancreatitis (A-GP and C-GP), and A-GP being further distinguished into: physiological (P-AGP), early (E-AGP) and late AP (L-AGP). Graft pancreatitis is the second most-frequent complication following pancreas transplantation. P-AGP is an unavoidable entity related to ischemic reperfusion injury. It is usually clinically silent. It is a timely and prognostically self-limited process. E-AGP occurs within 3 months after pancreas transplantation (PTx) in 35% of cases and is associated with high rates of graft loss (78-91%). Clinical signs are pain, systemic inflammatory response (SIRS) and haematuria. Therapy can be medical, interventional and surgical. L-AGP occurs 3 months following PTx in 14-25% of cases and represents an uncommon cause of graft loss. Typical clinical signs are pain, abdominal tenderness and fever. Typical laboratory signs are hyperamylasaemia, hyperglycaemia and hypercreatininaemia. Therapy is usually conservative. C-GP is difficult to be distinguished from chronic rejection and is associated to graft loss in 4-10% of cases. Recurrent A-GPs and infections are the main risk factors. Specific symptoms are chronic abdominal malaise, constipation and recurrence of DM. Isolated hyperglycaemia is typical of C-GP. The therapy is usually conservative. This systematic analysis of different manifestations of graft pancreatitis provides the basis for a clinical approach to tackling this complex entity.

  13. Synthesis and properties of silane-fluoroacrylate grafted starch.

    Science.gov (United States)

    Qu, Jia; He, Ling

    2013-10-15

    The latex of silane-fluoroacrylate grafted starch for coating materials, VTMS-starch/P(MMA/BA/3FMA), is obtained by two step grafting reactions. Vinyltrimethoxysilane (VTMS) is primarily grafted onto starch by condensation between Si-OH and C-OH at 120 °C, and then the copolymer of methyl methacrylate (MMA), butyl acrylate (BA) and 2,2,2-trifluoroethyl methacrylate (3FMA) is grafted onto the VTMS-starch by emulsion polymerization. Fourier transform infrared spectrometry (FTIR) and X-ray photoelectron spectroscopy (XPS) have been used to confirm the chemically grafting reactions in every step. The conversion percent, grafting percent and grafting efficiency for VTMS-starch/p(MMA/BA/3FMA) latex indicate that the optimum conditions should be controlled at 75 °C for 1h as VTMS-starch/P(MMA/BA/3FMA) in 1/3 weight ratio. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis have revealed that the latexes exhibit the uniform spherical particles of 40-60 nm in a narrow size distribution. The latex films perform the obvious hydrophobic (107°) property, lower surface free energy (25-35 mN/m) and the higher thermostability (330-440 °C) than starch (51°, 51.32 mN/m, 100-330 °C). Dynamic thermomechanical analysis (DMA) shows that the latex film could gain considerable toughness and strength with an elongation at break of 39.45% and a tensile strength of 11.97 MPa. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Hepatic Encephalopathy

    Medline Plus

    Full Text Available ... friend, spouse, life partner, parent, sibling or other family member. What is HE? Hepatic Encephalopathy, sometimes referred ... disease is. It’s important for you and your family to become familiar with the signs of Hepatic ...

  15. Honey: A Skin Graft Fixator Convenient for Both Patient and Surgeon.

    Science.gov (United States)

    Maghsoudi, Hemmat; Moradi, Sohrab

    2015-12-01

    Skin grafts can be used effectively to cover burn injuries. A critical element of this treatment is the adherence of the graft to the wound bed. Honey has been shown to increase the adherence of skin grafts to wound beds and have antibacterial and anti-inflammatory effects and increase healing rate of wounds. We therefore devised a clinical trial to determine the effect of honey on skin graft fixation in burn injuries. Sixty patients were included in this study (in 30 patients, graft was fixed with medical honey, and in 30 patients, it was fixed with dressing or suturing). All patients in two groups were evaluated for infection, graft loss, graft contraction, severity of pain, and need for re-operation. The most common cause of burn was kerosene. Honey significantly decreased infection rate on fifth day and reduced the patient pain. The mean hospital stay was shorter in honey group. Contraction of graft was significantly less in honey group. Honey has strong adhesive properties for skin graft fixation. Medical honey is a natural material, not synthetic. For this reason, we can advise the application of medical honey for the fixation of split thickness skin graft.

  16. Management of Industrial Dye Wastes Through Adsorption By Functionalized Graft Copolymers

    International Nuclear Information System (INIS)

    El-Nagger Abdel-Wahab, M.; Hegazy El-Sayed, A.; Aly Hussein, A.; Zahran Abdel-Hamid, H.

    1999-01-01

    The sorption of Methyl Green (basic dye) by different grafted polymers with individual acrylonitrile (AN) and its binary comonomer mixture with N-vinylpyrrolidone (NVP) has been investigated. It was found that at approximately equal levels of graft yield of AN, poly(tetrafluoroethylene-hexafluoropropylene)(FEP) showed the highest dye sorption of the basic dye while the grafted low density polyethylene (LDPE) displayed the lowest dye sorption. On the other hand, the different grafted polymers with AN/NVP binary monomers which having an approximately equal total graft yield (TGY) showed a dye sorption for the same basic dye according to the order: HDPE>FEP> LDPE>PP. Nevertheless, it was found that the dye sorption values by the grafted polymers with AN/NVP mixtures are much higher than those by the grafted polymers with individual AN monomer. The dye ability of HDPE grafted with individual AN and the comonomer mixture AN/NVP towards basic and disperse dyes was utilized to investigate the synergism during radiation grafting of the comonomer mixture. Results showed that such graft materials are promising in practical use for the treatment of industrial dye wastes from textile factories

  17. Pasteurized intercalary autogenous bone graft: radiographic and scintigraphic features

    International Nuclear Information System (INIS)

    Ehara, Shigeru; Tamakawa, Yoshiharu; Nishida, Jun; Shiraishi, Hideo

    2000-01-01

    Objective. Pasteurized autogenous bone graft sterilized at a low temperature (60 C) is one option for reconstruction after resection of bone and soft tissue tumors. The purpose of this investigation was to assess the normal and abnormal radiographic and scintigraphic findings of pasteurized intercalary autogenous bone graft after resection of bone and soft tissue sarcomas.Design. This was a retrospective evaluation of the radiography and bone scintigraphy findings in patients after treatment of bone and soft tissue sarcomas using an intercalary pasteurized autogenous bone graft.Patients. Among 10 consecutive patients, eight had intercalary grafts, and they constitute the subjects of this study. All available radiography and bone scintigraphy findings were reviewed for the healing process and the possibility of complications.Results and conclusions. Healing and incorporation of the graft were observed in five patients during the follow-up, but the other three did not heal satisfactorily. Rapid incorporation of pasteurized autogenous bone graft can be demonstrated by means of radiography and bone scintigraphy. (orig.)

  18. Revascularization of calvarial, mandibular, tibial, and iliac bone grafts in rats

    DEFF Research Database (Denmark)

    Pinholt, E M; Solheim, E; Talsnes, O

    1994-01-01

    Some studies have suggested that membranous bone grafts undergo less resorption than endochondral grafts, and faster revascularization of the former has been proposed as the explanation. We studied fresh syngeneic full-thickness bone grafts from calvaria, mandibula, tibia diaphysis, and iliac bone...... implanted in the back muscles of young Lewis rats. As a measure of the quantity of cancellous bone in grafts before implantation, the ratio of the total area of soft-tissue spaces to the total area of the graft was measured histomorphometrically. Revascularization in grafts 3 weeks postoperatively...... was evaluated by deposit of 141Ce-labeled microspheres. Both the quantity of cancellous bone (before implantation) and the revascularization (3 weeks postoperatively) were greater in the mandibular and iliac bone grafts than in the calvarial and tibia diaphyseal grafts. The results suggest that the anatomical...

  19. ILDR2: an endoplasmic reticulum resident molecule mediating hepatic lipid homeostasis.

    Directory of Open Access Journals (Sweden)

    Kazuhisa Watanabe

    Full Text Available Ildr2, a modifier of diabetes susceptibility in obese mice, is expressed in most organs, including islets and hypothalamus, with reduced levels in livers of diabetes-susceptible B6.DBA mice congenic for a 1.8 Mb interval of Chromosome 1. In hepatoma and neuronal cells, ILDR2 is primarily located in the endoplasmic reticulum membrane. We used adenovirus vectors that express shRNA or are driven by the CMV promoter, respectively, to knockdown or overexpress Ildr2 in livers of wild type and ob/ob mice. Livers in knockdown mice were steatotic, with increased hepatic and circulating triglycerides and total cholesterol. Increased circulating VLDL, without reduction in triglyceride clearance suggests an effect of reduced hepatic ILDR2 on hepatic cholesterol clearance. In animals that overexpress Ildr2, hepatic triglyceride and total cholesterol levels were reduced, and strikingly so in ob/ob mice. There were no significant changes in body weight, energy expenditure or glucose/insulin homeostasis in knockdown or overexpressing mice. Knockdown mice showed reduced expression of genes mediating synthesis and oxidation of hepatic lipids, suggesting secondary suppression in response to increased hepatic lipid content. In Ildr2-overexpressing ob/ob mice, in association with reduced liver fat content, levels of transcripts related to neutral lipid synthesis and cholesterol were increased, suggesting "relief" of the secondary suppression imposed by lipid accumulation. Considering the fixed location of ILDR2 in the endoplasmic reticulum, we investigated the possible participation of ILDR2 in ER stress responses. In general, Ildr2 overexpression was associated with increases, and knockdown with decreases in levels of expression of molecular components of canonical ER stress pathways. We conclude that manipulation of Ildr2 expression in liver affects both lipid homeostasis and ER stress pathways. Given these reciprocal interactions, and the relatively extended time

  20. Grafting of acrylic acid onto polypropylene films irradiated with argon ions

    International Nuclear Information System (INIS)

    Massa, G.; Mazzei, R.; Garcia Bermudez, G.; Filevich, A.; Smolko, E.

    2005-01-01

    Polypropylene (PP) foils were irradiated with 100 keV energy Argon ions at different fluences ranging from 10 12 up to 2 x 10 15 cm -2 and then grafted with acrylic acid (AA). The grafting yield was measured by weight difference and the structural changes on the films were analysed using Fourier transform infrared spectroscopy (FTIR). Different parameters that determined the grafting process such us fluence, grafting time and monomer concentration were analysed. The grafting reached an optimum value at 79% in aqueous solution at 30 min grafting time. The grafting yield as a function of the ion fluence plot, presented a maximum value, as previously found in a study of heavy beam on polymers