WorldWideScience

Sample records for exposure dependent x-ray

  1. Energy and rate dependence of diagnostic x-ray exposure meters

    International Nuclear Information System (INIS)

    Wagner, L.K.; Cerra, F.; Conway, B.; Fewell, T.R.; Ohlhaber, T.R.

    1988-01-01

    Variations in x-ray exposure measurements among a variety of contemporary diagnostic exposure meters are investigated. Variations may result from systematic errors due to calibration, beam-quality dependence and exposure-rate dependence. It is concluded that the majority of general purpose diagnostic meters will agree to within 10% of each other if exposure rates are below 1.3 mC kg-1S-1 of air (5 R s-1) and beam qualities are typical for general purpose radiology, excluding mammography. For exposure rates comparable to those in barium enema radiography the variations can range up to 25% or more. Variations up to 40% were observed among general purpose exposure meters at mammographic beam qualities. In the mammographic range, mammographic (thin window) exposure meters varied by no more than 2%

  2. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  3. X-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients and a skeleton encased in plastic were instrumented with LiF thermoluminescent dosimeters to determine radiation exposures delivered from full-face diagnostic dental X-rays. Measurements were made using various panoramic radiographical and periapical machines. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices. (author)

  4. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  5. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  6. Exposure of nitrous oxide to X-rays

    International Nuclear Information System (INIS)

    Yanagida, H.

    1980-01-01

    A study was performed to determine how much NO and NO 2 is produced when nitrous oxide is exposed to X-radiation. Polyethylene bottles filled with either nitrous oxide alone or with nitrous oxide and 30% oxygen were placed 30 cm from the X-ray tube at a standard X-ray beam setting for chest fluoroscopy for 0 to 5 minutes. In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray exposure, this study suggests another potentially hazardous interaction that may occur secondary to the administration of an anaesthetic in the presence of X-irradiation as in pulmonary angiography, cardiac catheterisation, and fluoroscopic bronchoscopy or biopsy. (author)

  7. Nitrous oxide pollution during x-ray exposure

    International Nuclear Information System (INIS)

    Yanagida, Hisashi; Nakajima, Michiaki.

    1980-01-01

    X-radiation has been shown to produce NO and NO 2 in the presence of nitrous oxide. The purpose of the present study was to confirm how much NO and NO 2 was produced when constant amount of nitrous oxide was exposed by constant X-radiation. Twenty polyethylene bottles (capacity 10 litres) were filled with nitrous oxide alone. Another 20 bottles were filled with nitrous oxide and 30% oxygen. Each bottle was placed at a distance of 30 cm from X-ray tube and they were directly in the line of the X-ray beam at a setting of 90 KV at 0.5 mA, a standard setting for chest fluoroscopy. The range of duration of X-ray exposure was from 0 (control), to 2, 3, and 5 minutes in 5 bottles each, respectively. A colorimetric recording method (Saltzman) and a chemiluminescent monitor were used for measurement of NO and NO 2 . In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray, this study suggests another potentially hazardous interaction that may occur secondary to the administration of anesthetic in the presence of X-irradiation such as pulmonary angiography, cardiac catheterization, and fluoroscopic bronchoscopy or biopsy under general anesthesia. (author)

  8. Preparation of exposures charts for X-ray tubes

    International Nuclear Information System (INIS)

    Zoofan, B.

    1988-01-01

    An exposure chart is a fundamental graph which provides guidance of the exposure conditions in relation to the thickness for a given specimen. It must be prepared specially for the X-ray unit and the type of the film to be used. Although exposure charts are available for each particular X-ray tube from its manufacturer, individual radiographic laboratory should be able to prepare its own exposure charts in a precise manner. Here a typical procedure to prepare such a chart is provided in a practical way with some necessary recommendations

  9. X-ray exposure from colour TV sets

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Viswanathan, P.S.

    1988-01-01

    A survey has been made of the X-ray exposures from colour television sets of eight different brands manufactured in India and one of foreign make. The high sensitivity of natural CaF 2 TL phosphor to low energy photons has been taken advantage of, in measuring the extremely low levels of the X-ray emis sion from the TV sets. The measured exposures range from 8 to 27 μRh -1 and are well below the radiation safety limit internationally adopted. (author). 4 tabs

  10. Excessive exposures of diagnostic X-ray workers in India

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Shenoy, K.S.; Patel, P.H.

    1980-01-01

    The excessive exposures (i.e. exceeding 400 mrems per fortnight) of diagnostic X-ray workers revealed under the countrywide personnel monitoring programme in India have been analysed. The analysis covers the data collected over a period of ten years during 1965-1974. The radiation workers in medical X-ray diagnostic group receiving an excess dose are found to be less than 1%. Each case of the excess dose is throughly investigated and nongenuine cases are separated and causes for genuine excessive exposures are traced. The causes and the corrective measures are enumerated. (M.G.B.)

  11. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  12. X-ray survey of the Pleiades: dependence of X-ray luminosity on stellar age

    International Nuclear Information System (INIS)

    Micela, G.; Sciortino, S.; Serio, S.; Vaiana, G.S.; Golub, L.; Harnden, F.R.; Rosner, R.

    1984-01-01

    The study of X-ray emission of stellar clusters, allows to decouple the influence of some individual stellar parameters, as initial conditions, composition and age, on the stellar X-ray function. The authors report preliminary results from an Einstein X-ray survey of the Pleiades. (Auth.)

  13. Prenatal x-ray exposure and childhood cancer in twins

    International Nuclear Information System (INIS)

    Harvey, E.B.; Boice, J.D. Jr.; Honeyman, M.; Flannery, J.T.

    1985-01-01

    A case-control study was conducted to investigate the relation between prenatal exposure to x-rays and childhood cancer, including leukemia, in over 32,000 twins born in Connecticut from 1930 to 1969. Twins as opposed to single births were chosen for study to reduce the likelihood of medical selection bias, since twins were often exposed to x-rays to diagnose the twin pregnancy or to determine fetal positioning before delivery and not because of medical conditions that may conceivably pre-dispose to cancer. Each of 31 incident cases of cancer, identified by linking the Connecticut twin and tumor registries, was matched with four twin controls according to sex, year of birth, and race. Records of hospitals, radiologists, and private physicians were searched for histories of x-ray exposure and other potentially important risk factors. Documented prenatal x-ray exposures were found for 39 per cent of the cases (12 of 31) and for 26 per cent of the controls (28 of 109). No other pregnancy, delivery, or maternal conditions were associated with cancer risk except low birth weight: 38 per cent of the cases as compared with 25 per cent of the controls weighed under 2.27 kg at birth. When birth weight was adjusted for, twins in whom leukemia or other childhood cancer developed were twice as likely to have been exposed to x-rays in utero as twins who were free of disease (relative risk, 2.4; 95 per cent confidence interval, 1.0 to 5.9). The results, though based on small numbers, provide further evidence that low-dose prenatal irradiation may increase the risk of childhood cancer

  14. Accidental over-exposure from dental X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, B G [National Radiological Protection Board, Harwell (UK)

    1976-07-01

    A description is given of an unusual dental X-ray procedure which resulted in accidental over-exposure both to the dentist and to several of his patients when a short-circuit was present in newly-installed equipment. The short-circuit by-passed the exposure control and energized the tube for certain orientations of the X-ray tube. The dentist left the patients, who wore protective aprons, to initiate the exposure themselves, using the control button. Although the warning lights were on, the dentist was not present in the room during the exposure, and the over-exposures were only detected when the developed X-ray films were found to be completely blackened. A reconstruction of the procedure enabled estimates to be made of the dose equivalents to the dentist's body and to the skin of the head, the eyes and the gonads of the patients. The dentist had overlooked several of basic principles recommended in the Code of Practice for the Protection of Persons against Ionizing Radiations from Medical and Dental Use (1972). It is pointed out that incidents involving failure of dental equipment (usually the timer mechanism) are not infrequent.

  15. Constancy of radiation output during diagnostic X-ray exposures

    International Nuclear Information System (INIS)

    Ardran, G.M.; Crooks, H.E.; Birch, R.

    1978-01-01

    Variation in X-ray output and quality during a diagnostic exposure can be undesirable and may result in unnecessary dose to the patient. When significant build-up or decay periods are present errors will arise if factors obtained under steady-state conditions are employed to estimate the exposure. These parameters must be taken into account when calibrating X-ray generators. A variable speed spinning film device and a spectrometry system have been used to measure the variations under fluoroscopic and radiographic conditions for a number of generators. Variations in output due to filament heating, voltage supply and rectification, cable capacity and target pitting have been demonstrated. At low fluoroscopic currents, large surges and long decays have been observed; the significance of these effects is considered. (author)

  16. Radiation exposure in X-ray studies of the hips

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F [Krankenhaus der Barmherzigen Brueder, Salzburg (Austria). Roentgeninstitut

    1979-12-01

    The genetic exposure of the small child is above all a consequence of the rapid increase in X-ray studies, a problem which has not yet been settled. Through phantom measurements it can be shown, that dose reduction is of considerable practical significance if appropriate lead shielding is employed. The radiation dose can be significantly reduced, provided that the shielding material is of an appropriate lead equivalent. The form of the pelvic shield which is used is also of crucial importance.

  17. [Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation].

    Science.gov (United States)

    Olszewski, Jerzy; Wrzesień, Małgorzata

    2017-06-27

    The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491-496. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  18. Accidental exposure with X-ray diffraction equipment

    International Nuclear Information System (INIS)

    Montanez, O.; Blanco, D.

    1991-01-01

    The shutter on one of the windows of an X-ray diffraction apparatus was accidentally left open, exposing the worker to the radiation. The worker was wearing a dosimeter film, which was processed immediately to evaluate the potential risk. It was determined that the exposure rate was 350 Roentgen/minute on the skin surface, with corrections being made for the worker's thin clothing. It was concluded that in spite of the worker receiving a relative high dose, it did not reach the threshold value for producing deterministic effects such as cataracts, erythema, and skin damage

  19. Implementation of a primary standard for x-ray exposure

    International Nuclear Information System (INIS)

    Peixoto, Jose Guilherme Pereira

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-ray s of 10OKV to 250kV of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Since the collecting rod is small, and positioned far away from the X-ray beam, only a negligible fraction of ionization (0,01 %) is lost due to interactions with it. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation , beam homogeneity, influence Of beam size and influences of temperature, humidity and atmospheric pressure.Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  20. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  1. Radiation exposure in X-ray examinations of the pelvis

    International Nuclear Information System (INIS)

    Kainberger, F.

    1977-01-01

    The article reports on radiation exposure during X-ray treatment of the pelvis of children. Special attention is paid to genetical radiation exposure. Generally a dose of 100 mR is assumed to be taken up if no adequate shielding is provided. In order to be able to judge the value of a shielding with suitable lead-equivalent values, measurements were carried out on a phantom. These measurements showed that the dosage can be reduced by at least a factor 100 by using a lead shielding. When doing this, the lead equivalent value must be 1 mm. The form of gonad protection also has great importance for the shielding efficiency. (orig.) [de

  2. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  3. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  4. Einstein X-ray survey of the Pleiades - The dependence of X-ray emission on stellar age

    Science.gov (United States)

    Micela, G.; Sciortino, S.; Serio, S.; Vaiana, G. S.; Bookbinder, J.; Golub, L.; Harnden, F. R., Jr.; Rosner, R.

    1985-01-01

    The data obtained with two pointed observations of 1 deg by 1 deg fields of the Pleiades region have been analyzed, and the results are presented. The maximum-likelihood X-ray luminosity functions for the Pleiades G and K stars in the cluster are derived, and it is shown that, for the G stars, the Pleiades X-ray luminosity function is significantly brighter than the corresponding function for Hyades G dwarf stars. This finding indicates a dependence of X-ray luminosity on stellar age, which is confirmed by comparison of the same data with median X-ray luminosities of pre-main sequence and local disk population dwarf G stars. It is suggested that the significantly larger number of bright X-ray sources associated with G stars than with K stars, the lack of detection of M stars, and the relatively rapid rotation of the Pleiades K stars can be explained in terms of the onset of internal differential rotation near the convective envelope-radidative core interface after the spin-up phase during evolution to the main sequence.

  5. Cytogenetic studies with laser or X-ray exposures

    International Nuclear Information System (INIS)

    Bozduganov, A.; Genkov, P.

    1975-01-01

    Account is given of studies involving a total of 21 peripheral blood cultures given the following treatments: exposure to 20 0.13-joule pulses from an optic quantum generator (ruby), 9; exposure to 1000 R X-rays, 9; and unexposed controls, 3. Exposures were carried out on three cultures from each experimental series at each of three time intervals, namely 24 h, 48 h, and 72 h after initiation of cultures. On any day, 40 well-spread metaphases were examined. High quality metaphases were photographed and karyotyped in conformity to the Chicago Conference criteria. In the laser experiment, chromosome aberrations were observed in 65% of methaphases analyzed vs. 5.3% in controls. Anomalies encountered included aneuploidy, with hypoploid metaphases predominating, polyploidy (triploidy, tetraploidy, and partial endoreduplication), and structural alterations. The following structural chromosome rearrangements are found: acentric fragments, mostly pairs, occasionally single, including minute chromosomes; dicentric and tricentric chromosomes; interstitial deletions; and chromosome translocations. Most varied and abundant chromosome aberrations were seen in 72-h irradiated cultures. The data presented offer a new opportunity for assessing genetic lesions after laser exposure and may help to determine threshold doses. (author)

  6. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  7. Exposure reduction in general dental practice using digital x-ray imaging system for intraoral radiography with additional x-ray beam filter

    International Nuclear Information System (INIS)

    Shibuya, Hitoshi; Mori, Toshimichi; Hayakawa, Yoshihiko; Kuroyanagi, Kinya; Ota, Yoshiko

    1997-01-01

    To measure exposure reduction in general dental practice using digital x-ray imaging systems for intraoral radiography with additional x-ray beam filter. Two digital x-ray imaging systems, Pana Digital (Pana-Heraus Dental) and CDR (Schick Technologies), were applied for intraoral radiography in general dental practice. Due to the high sensitivity to x-rays, additional x-ray beam filters for output reduction were used for examination. An Orex W II (Osada Electric Industry) x-ray generator was operated at 60 kVp, 7 mA. X-ray output (air-kerma; Gy) necessary for obtaining clinically acceptable images was measured at 0 to 20 cm in 5 cm steps from the cone tip using an ionizing chamber type 660 (Nuclear Associates) and compared with those for Ektaspeed Plus film (Eastman Kodak). The Pana Digital system was used with the optional filter supplied by Pana-Heraus Dental which reduced the output to 38%. The exposure necessary to obtain clinically acceptable images was only 40% of that for the film. The CDR system was used with the Dental X-ray Beam Filter Kit (Eastman Kodak) which reduced the x-ray output to 30%. The exposure necessary to obtain clinically acceptable images was only 20% of that for the film. The two digital x-ray imaging systems, Pana Digital and CDR, provided large dose savings (60-80%) compared with Ektaspeed Plus film when applied for intraoral radiography in general dental practice. (author)

  8. Prepulse dependence in hard x-ray generation from microdroplets

    International Nuclear Information System (INIS)

    Anand, M.; Kahaly, S.; Kumar, G. Ravindra; Sandhu, A. S.; Gibbon, P.; Krishnamurthy, M.

    2006-01-01

    We report on experiments which show that liquid microdroplets are very efficient in hard x-ray generation. We make a comparative study of hard x-ray emission from 15 μm methanol microdroplets and a plain slab target of similar atomic composition at similar laser intensities. The hard X-ray yield from droplet plasmas is about 35 times more than that obtained from solid plasmas. A prepulse that is about 10ns and at least 2% in intensity of the main pulse is essential for hard x-ray generation from the droplets at about 1015 W cm-2. A hot electron temperature of 36 keV is measured from the droplets at 8 x 1014 W cm-2; three times higher intensity is needed to obtain similar hot electron temperature from solid plasmas that have similar atomic composition. We use 1D-PIC simulation to obtain qualitative correlation to the experimental observations

  9. Time dependence of X-ray polarizability of a crystal induced by an intense femtosecond X-ray pulse

    Directory of Open Access Journals (Sweden)

    A. Leonov

    2014-11-01

    Full Text Available The time evolution of the electron density and the resulting time dependence of Fourier components of the X-ray polarizability of a crystal irradiated by highly intense femtosecond pulses of an X-ray free-electron laser (XFEL is investigated theoretically on the basis of rate equations for bound electrons and the Boltzmann equation for the kinetics of the unbound electron gas. The photoionization, Auger process, electron-impact ionization, electron–electron scattering and three-body recombination have been implemented in the system of rate equations. An algorithm for the numerical solution of the rate equations was simplified by incorporating analytical expressions for the cross sections of all the electron configurations in ions within the framework of the effective charge model. Using this approach, the time dependence of the inner shell populations during the time of XFEL pulse propagation through the crystal was evaluated for photon energies between 4 and 12 keV and a pulse width of 40 fs considering a flux of 1012 photons pulse−1 (focusing on a spot size of ∼1 µm. This flux corresponds to a fluence ranging between 0.8 and 2.4 mJ µm−2. The time evolution of the X-ray polarizability caused by the change of the atomic scattering factor during the pulse propagation is numerically analyzed for the case of a silicon crystal. The time-integrated polarizability drops dramatically if the fluence of the X-ray pulse exceeds 1.6 mJ µm−2.

  10. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  11. Combined exposure of ELF magnetic fields and X-rays increased mutant yields compared with X-rays alone in pTN89 plasmids

    International Nuclear Information System (INIS)

    Koyama, Shin; Nakahara, Takehisa; Sakurai, Tomonori; Komatsubara, Yoshiki; Miyakoshi, Junji; Isozumi, Yasuhito

    2005-01-01

    We have examined mutations in the supF gene carried by pTN89 plasmids in Escherichia coli (E. coli) to examine the effects of extremely low frequency magnetic fields (ELFMFs) and/or X-rays to the plasmids. The plasmids were subjected to sham exposure or exposed to an ELFMF (5 mT), with or without X-ray irradiation (10 Gy). For the combined treatments, exposure to the ELFMF was immediately before or after X-ray irradiation. The mutant fractions were 0.94 x 10 -5 for X-rays alone, 1.58 x 10 -5 for an ELFMF followed by X-rays, and 3.64 x 10 -5 for X-rays followed by an ELFMF. Increased mutant fraction was not detected following exposure to a magnetic field alone, or after sham exposure. The mutant fraction for X-rays followed by an ELFMF was significantly higher than those of other treatments. Sequence analysis of the supF mutant plasmids revealed that base substitutions were dominant on exposure to X-rays alone and X-rays plus an ELFMF. Several types of deletions were detected in only the combined treatments, but not with X-rays alone. We could not find any mutant colonies in sham irradiated and an ELFMF alone treatment, but exposure to ELFMFs immediately before or after X-ray irradiation may enhance the mutations. Our results indicate that an ELFMF increases mutation and alters the spectrum of mutations. (author)

  12. Differences in responses to X-ray exposure between osteoclast and osteoblast cells

    International Nuclear Information System (INIS)

    Zhang, Jian; Wang, Ziyang; Wu, Anqing; Nie, Jing; Pei, Hailong; Hu, Wentao; Wang, Bing; Shang, Peng; Li, Bingyan; Zhou, Guangming

    2017-01-01

    Radiation-induced bone loss is a potential health concern for cancer patients undergoing radiotherapy. Enhanced bone resorption by osteoclasts and decreased bone formation by osteoblasts were thought to be the main reasons. In this study, we showed that both pre-differentiating and differentiating osteoclasts were relatively sensitive to X-rays compared with osteoblasts. X-rays decreased cell viability to a greater degree in RAW264.7 cells and in differentiating cells than than in osteoblastic MC3T3-E1 cells. X-rays at up to 8 Gy had little effects on osteoblast mineralization. In contrast, X-rays at 1 Gy induced enhanced osteoclastogenesis by enhanced cell fusion, but had no effects on bone resorption. A higher dose of X-rays at 8 Gy, however, had an inhibitory effect on bone resorption. In addition, actin ring formation was disrupted by 8 Gy of X-rays and reorganized into clusters. An increased activity of Caspase 3 was found after X-ray exposure. Actin disorganization and increased apoptosis may be the potential effects of X-rays at high doses, by inhibiting osteoclast differentiation. Taken together, our data indicate high radiosensitivity of osteoclasts. X-ray irradiation at relatively low doses can activate osteoclastogenesis, but not osteogenic differentiation. The radiosensitive osteoclasts are the potentially responsive cells for X-ray-induced bone loss.

  13. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  14. X-ray exposure in utero and school performance: a population-based study of X-ray pelvimetry

    International Nuclear Information System (INIS)

    Nordenskjöld, A.C.; Palme, M.; Kaijser, M.

    2015-01-01

    Aim: To investigate the association between exposure to ionising radiation from pelvimetric examinations in utero and school performance. Material and methods: This was a population-based cohort study comprising 46,066 children born in the county of Östergötland, Sweden, from 1980 through 1990. Through record linkage between Swedish registers, children exposed in utero to X-ray pelvimetry examination were compared to other children born in the same county during the study period, as well as to their unexposed siblings. Outcome variable was primary school grades, expressed in centiles and calculated through linear regression. Results: In the univariate analysis, children exposed to X-ray pelvimetry in utero had higher school grades compared to unexposed children (point estimate 3 centiles, 95% confidence interval [CI]: 1.5 to 4.6). When sex, mother's education and income, birth order, and birth position were included in the analysis; however, the difference was reduced and the association was no longer statistically significant (PE 1.4, 95% CI: –0.1 to 2.8). Comparing exposed children with their siblings showed no statistical difference in univariate analysis or in multivariate analysis. Conclusion: No suggestion was found of a negative effect on school performance from in utero exposure of diagnostic X-ray pelvimetry. -- Highlights: •Pelvimetric examinations expose fetus to low levels of radiation. •No detectable effect on childrens final primary school grades from pelvimetric examinations. •Pelvimetric examinations is a safe procedure for the fetus regarding shool performance

  15. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  16. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  17. Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters

    International Nuclear Information System (INIS)

    Agba, E.H.; Uloko, P. I.; Tyovenda, A. A.

    2011-01-01

    Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters of the x-ray machines has been carried out. Three phase diagnostic x-ray machines situated at Federal Medical Centre, Makurdi, General Hospital, Otukpo and Christian Hospital, Mkar were used for the calibration work. The radiation meter was used to measure x-ray radiation exposure. The result of this work demonstrates mR/mAs=C(KV p ) that there exist a power law relation of the form between the radiation exposure and the radiographic parameters of diagnostic x-ray machines, which can be used to estimate patient exposure during routine x-ray diagnostic examinations for wide range of operating parameters. The values of the power exponent n, constant c and total filtrations of the diagnostic x-ray machines have been estimated. These values for the diagnostic x-ray machines at the Federal Medical Centre, Makurdi are: 2.14, 0.88 and 2.77 respectively, for the one at the General Hospital, Otukpo are: 2.07, 0.76 and 2.68 respectively and that of the Christian Hospital, Mkar are: 2.01,0.69 and 2.61 respectively.

  18. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  19. Deformation and stress in PMMA during hard X-ray exposure for deep lithography

    International Nuclear Information System (INIS)

    Moldovan, N.

    1999-01-01

    The availability of high-energy, high-flux, collimated synchrotrons radiation has extended the application of deep X-ray lithography (DXRL) to thickness values of the PMMA resist of several millimeters. Some of the most severe limitations come from plastic deformation, stress, and cracks induced in PMMA during exposure and development. We have observed and characterized these phenomena quantitatively. Profilometry measurements revealed that the PMMA is subjected either to local shrinkage or to expansion, while compression and expansion evolve over time. Due to material loss and crosslinking, the material undergoes a shrinkage, while the radiation-induced decomposition generates gases expanding the polymer matrix. The overall dynamics of the material microrelief and stress during and after the exposure depend on the balance between compaction and outgassing. These depend in turn on the exposure conditions (spectrum; dose, dose rate, seaming, temperature), post-exposure storage conditions, PMMA material properties and thickness, and also on the size and geometry of the exposed patterns

  20. Luminosity dependence in the ratio of X-ray to infrared emission of QSOs

    International Nuclear Information System (INIS)

    Worrall, D.M.

    1987-01-01

    The correlation of X-ray and near-infrared luminosity is studied for a sample of radio-quiet QSOs. The X-ray to infrared ratio is found to decrease as the infrared luminosity increases. No preference is found between the correlations of X-ray luminosity with optical or infrared luminosity. This implies that optical and infrared emission are equally good predictors of X-ray emission. Source models which directly link infrared and X-ray emission are discussed, and a preference is found for a specific synchrotron self-Compton model. This model predicts the correct luminosity dependence of the X-ray to infrared ratio if certain conditions apply. 55 references

  1. Phase-dependent absorption features in X-ray spectra of X-ray Dim Isolated Neutron Stars

    Science.gov (United States)

    Borghese, A.; Rea, N.; Coti Zelati, F.; Turolla, R.; Tiengo, A.; Zane, S.

    2017-12-01

    A detailed phase-resolved spectroscopy of archival XMM-Newton observations of X-ray Dim Isolated Neutron Stars (XDINSs) led to the discovery of narrow and strongly phase-dependent absorption features in two of these sources. The first was discovered in the X-ray spectrum of RX J0720.4-3125, followed by a new possible candidate in RX J1308.6+2127. Both spectral lines have similar properties: they are detected for only ˜ 20% of the rotational cycle and appear to be stable over the timespan covered by the observations. We performed Monte Carlo simulations to test the significance of these phase-variable features and in both cases the outcome has confirmed the detection with a confidence level > 4.6σ. Because of the narrow width and the strong dependence on the pulsar rotational phase, the most likely interpretation for these spectral features is in terms of resonant proton cyclotron absorption scattering in a confined high-B structure close to the stellar surface. Within the framework of this interpretation, our results provide evidence for deviations from a pure dipole magnetic field on small scales for highly magnetized neutron stars and support the proposed scenario of XDINSs being aged magnetars, with a strong non-dipolar crustal B-field component.

  2. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  3. The parameters of X-ray equipment that influence in patient exposure

    International Nuclear Information System (INIS)

    Peixoto, J.E.

    1988-01-01

    The main components of the X-rays equipment and the secondary device for radiodiagnosis examination are showed. The influence of all radiographs parameters in human exposure as tension and current are also analysed. (C.G.C.) [pt

  4. Influence of X-ray exposure on morphologic composition of blood of sheep

    International Nuclear Information System (INIS)

    Tukhtaev, T.M.; Badalov, S.

    1983-01-01

    Present article is devoted influence of X-ray exposure on morphologic composition of blood of sheep. Thus, pathogenetic mechanisms of formation of acute radiation sickness of laboratory animals are studied. The experiments are described.

  5. Design And Measurement Of Radiation Exposure Rates At An X-Ray Diagnostic Radiological Unit

    International Nuclear Information System (INIS)

    Tito-Sutjipto

    2003-01-01

    Every radiation employees suffers radiation exposure risk while doing his job. It is important therefore to investigate the occupational health and safety of radiation employees on its relationship with the design and measurement of radiation exposure rates at an X-ray diagnostic radiological unit in this work, a case study was held on the radiological unit at BP-4 Yogyakarta for patient diagnostics, This research armed to investigate the relationship between the design of radiological unit for X-ray diagnostics and the location of the X-ray machine, based on the distance variable and radiation exposure rate during patient diagnostics. This was performed using radiological unit design data for X-ray diagnostics and the measurement of radiation exposure rates throughout patient diagnostics. The design data can then be used for determining the requirement of primary and secondary shielding materials for radiological unit as well as a calculation basis of radiation exposure rates during patient diagnostics. From the result of the research, it can be concluded that from the occupational health and safety point of view, radiation exposure around the X-ray machines are fairly good, both for the shielding materials in each X-ray room and the radiation exposures received by the workers, because they are far beyond the maximum permittable average limit (16.67 m R/days). (author)

  6. Time-dependent nonequilibrium soft x-ray response during a spin crossover

    Energy Technology Data Exchange (ETDEWEB)

    van Veenendaal, Michel

    2018-03-01

    The rapid development of high-brilliance pulsed X-ray sources with femtosecond time resolution has created a need for a better theoretical understanding of the time-dependent soft-X-ray response of dissipative many-body quantum systems. It is demonstrated how soft-X-ray spectroscopies, such as X-ray absorption and resonant inelastic X-ray scattering at transition-metal L-edges, can provide insight into intersystem crossings, such as a spin crossover. The photoinduced doublet-to-quartet spin crossover on cobalt in Fe-Co Prussian blue analogues is used as an example to demonstrate how the X-ray response is affected by the dissipative nonequilibrium dynamics. The time-dependent soft-X-ray spectra provide a wealth of information that reflect the changes in the nonequilibrium initial state via continuously changing spectral lineshapes that cannot be decomposed into initial photoexcited and final metastable spectra, strong broadenings, a collapse of clear selection rules during the intersystem crossing, strong fluctuations in the isotropic branching ratio in X-ray absorption, and crystal-field collapse/oscillations and strongly time-dependent anti-Stokes processes in RIXS.

  7. Time-dependent nonequilibrium soft x-ray response during a spin crossover

    Science.gov (United States)

    van Veenendaal, Michel

    2018-03-01

    A theoretical framework is developed for better understanding the time-dependent soft-x-ray response of dissipative quantum many-body systems. It is shown how x-ray absorption and resonant inelastic x-ray scattering (RIXS) at transition-metal L edges can provide insight into ultrafast intersystem crossings of importance for energy conversion, ultrafast magnetism, and catalysis. The photoinduced doublet-to-quartet spin crossover on cobalt in Fe-Co Prussian blue analogs is used as a model system to demonstrate how the x-ray response is affected by the nonequilibrium dynamics on a femtosecond time scale. Changes in local spin and symmetry and the underlying mechanism are reflected in strong broadenings, a collapse of clear selection rules during the intersystem crossing, fluctuations in the isotropic branching ratio in x-ray absorption, crystal-field collapse and/or oscillations, and time-dependent anti-Stokes processes in RIXS.

  8. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  9. Pregnancy x-rays and childhood cancers: effects of exposure age and radiation dose

    International Nuclear Information System (INIS)

    Gilman, E.A.; Kneale, G.W.; Knox, E.G.; Stewart, A.M.

    1988-01-01

    Using data from the Oxford Survey of Childhood Cancers this paper examines the effect of foetal age and number of films used on the subsequent risk of childhood cancer associated with prenatal x-rays. X-rays early in pregnancy were taken for different reasons and required more films when compared with those taken in late pregnancy. Therefore, Mantel-Haenszel techniques were used to estimate the independent effects of (a) exposure age and (b) number of films. Age at exposure had a clearly significant effect; x-rays taken in the first trimester of pregnancy were 2.69 times as effective as x-rays taken in the third trimester. First trimester exposures were often the result of maternal illnesses, so these maternal illnesses were then included among the controlling factors. When this was done the first trimester x-rays were 2.73 times as effective as later exposures. First trimester x-rays were most strongly associated with the cancers which were diagnosed between 4 and 5 years of age. Although the number of films had no detectable effect upon relative risk calculated over all ages, multiple exposures were demonstrably associated with early age at diagnosis. (author)

  10. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  11. Exposure doses of the patient and the medical staff during urological X-ray examens

    International Nuclear Information System (INIS)

    Vogel, H.; Loehr, H.; Haug, P.; Schuett, B.

    1977-01-01

    During 32 intravenous urografies and 48 angiografies of the kidney and the suprarenal glands the X-ray doses at the patient's skin and gonades were determined. During the angiografies the doses were mesured at the hands. the gonades and the front (eyes) of the medical staff. The results are discussed. Because the X-ray doses are relatively high, the number of the pictures and the exposure time is to be reduced to the minimum. Clinical experience and special knowledge is the best X-ray protection. (orig.) [de

  12. Phototimer for automatic control of x-ray exposure, PT-20A

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, H; Itoh, K; Ogura, I; Yasuhara, H; Sugimoto, H [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-02-01

    The phototimer as an exposure control device is now required to have higher accuracy and wider range of control to comply with the recent trends of x-ray diagnosis, such as toward short-time exposure due to increased output power of x-ray apparatus and toward one-man operation. In order to meet the requirement, the x-ray characteristics of the components of the phototimer have been examined, and computer simulation of x-ray spectra and dynamic characteristics of every component have been investigated, in pursuit of the essential characters of phototimers. On the basis of these analytical investigations, the phototimer PT-20A is so designed as to compensate for density deviation under various kVp and object thickness: uniform density has been obtained under practical radiographic conditions.

  13. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  14. Effects of pre-natal X-ray exposure on learning behaviour of mice

    International Nuclear Information System (INIS)

    Frank, P.; Faber, U.; Budny, T.

    1983-01-01

    The authors investigated whether prenatal X-raying affects the learning behaviour of mice. For this purpose they irradiated mice of strain C57BL/6Ffm with 130 r at different points of the fetal phase. Unirradiated mice served as controls. The animals underwent two learning test series of 14 days each teaching them optical signs. The results of the test series show a distinctly inferior learning ability in the animals exposed to pre-natal irradiation as compared to unirradiated controls. The extent of the reduction of the learning ability depends on the stage of the pregnancy at the time of X-ray exposure. The greatest difference as compared to non-irradiated mice occurred in the animals irradiated at the earliest stage (13th/14th day of pregnancy). The results of the other test groups (15th/16th and 17th/18th day of pregnancy) exhibited less distinct, but still significant differences to the controls. Exposure at the latest period (17th/18th day) coincided with the smallest difference. (orig./MG) [de

  15. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  16. Intensity-dependent resonant transmission of x-rays in solid-density aluminum plasma

    Science.gov (United States)

    Cho, M. S.; Chung, H.-K.; Cho, B. I.

    2018-05-01

    X-ray free-electron lasers (XFELs) provide unique opportunities to generate and investigate dense plasmas. The absorption and transmission properties of x-ray photons in dense plasmas are important in characterizing the state of the plasmas. Experimental evidence shows that the transmission of x-ray photons through dense plasmas depends greatly on the incident XFEL intensity. Here, we present a detailed analysis of intensity-dependent x-ray transmission in solid-density aluminum using collisional-radiative population kinetics calculations. Reverse saturable absorption (RSA), i.e., an increase in x-ray absorption with intensity has been observed for photon energies below the K-absorption edge and in the intensity range of 1016-1017 W/cm2 for XFEL photons with 1487 eV. At higher intensities, a transition from RSA to saturable absorption (SA) is predicted; thus, the x-ray absorption decreases with intensity above a threshold value. For XFEL photon energies of 1501 eV and 1515 eV, the transition from RSA to SA occurs at XFEL intensities between 1017-1018 W/cm2. Electron temperatures are predicted to be in the range of 30-50 eV for the given experimental conditions. Detailed population kinetics of the charge states explains the intensity-dependent absorption of x-ray photons and the fast modulation of XFEL pulses for both RSA and SA.

  17. Dependence of X-Ray Burst Models on Nuclear Masses

    Energy Technology Data Exchange (ETDEWEB)

    Schatz, H.; Ong, W.-J. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States)

    2017-08-01

    X-ray burst model predictions of light curves and the final composition of the nuclear ashes are affected by uncertain nuclear masses. However, not all of these masses are determined experimentally with sufficient accuracy. Here we identify the remaining nuclear mass uncertainties in X-ray burst models using a one-zone model that takes into account the changes in temperature and density evolution caused by changes in the nuclear physics. Two types of bursts are investigated—a typical mixed H/He burst with a limited rapid proton capture process (rp-process) and an extreme mixed H/He burst with an extended rp-process. When allowing for a 3 σ variation, only three remaining nuclear mass uncertainties affect the light-curve predictions of a typical H/He burst ({sup 27}P, {sup 61}Ga, and {sup 65}As), and only three additional masses affect the composition strongly ({sup 80}Zr, {sup 81}Zr, and {sup 82}Nb). A larger number of mass uncertainties remain to be addressed for the extreme H/He burst, with the most important being {sup 58}Zn, {sup 61}Ga, {sup 62}Ge, {sup 65}As, {sup 66}Se, {sup 78}Y, {sup 79}Y, {sup 79}Zr, {sup 80}Zr, {sup 81}Zr, {sup 82}Zr, {sup 82}Nb, {sup 83}Nb, {sup 86}Tc, {sup 91}Rh, {sup 95}Ag, {sup 98}Cd, {sup 99}In, {sup 100}In, and {sup 101}In. The smallest mass uncertainty that still impacts composition significantly when varied by 3 σ is {sup 85}Mo with 16 keV uncertainty. For one of the identified masses, {sup 27}P, we use the isobaric mass multiplet equation to improve the mass uncertainty, obtaining an atomic mass excess of −716(7) keV. The results provide a roadmap for future experiments at advanced rare isotope beam facilities, where all the identified nuclides are expected to be within reach for precision mass measurements.

  18. Angle dependent focal spot size of a conical X-ray target

    International Nuclear Information System (INIS)

    Saeed Raza, Hamid; Jin Kim, Hyun; Nam Kim, Hyun; Oh Cho, Sung

    2015-01-01

    Misaligned phantoms may severely affect the focal spot calculations. A method is proposed to determine the geometry of the X-ray target and the position of the image radiograph around the X-ray target to get a relatively smaller focal spot size. Results reveal that the focal spot size is not always isotropic around the target but it decreases as the point of observation shifts radially away from the center line of the conical X-ray target. This research will help in producing high quality X-ray images in multi-directions by properly aligning the phantoms and the radiograph tallies. - Highlights: • Misaligned phantoms may severely affect the focal spot calculations. • The aim of this research is to analyze systematically the angle dependent behavior of the focal spot size around a conical shaped X-ray target. • A general purpose Monte Carlo (MCNP5) computer code is used to achieve a relatively small focal spot size. • Angular distribution of the X-ray focal spot size mainly depends on the angular orientation of the phantom and its aligned FIR tally. • This research will help in producing high quality X-ray images in multi-directions

  19. Dental X-ray diagnostic facility with means to choose the time of exposure

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Grassme, U

    1978-02-16

    Equipment for dental X-ray diagnostics with automatic exposure control. In the patient's mouth there is arranged a film carrier containing in a pocket a dental X-ray film. A detector-transmitter assembly touches the pocket. It reacts to the density of the film and wireless transmits a signal to an antenna. This antenna is connected to a receiver shutting off the high voltage of the X-ray tube by means of a circuit if a desired dose value is reached. The detector-transmitter unit is an integrated component. It has got a luminescent layer with a light-sensitive detector or a detector directly sensitive to X-rays.

  20. Risk assessment of medical exposure in X-ray examinations of children

    Directory of Open Access Journals (Sweden)

    I. G. Shatsky

    2017-01-01

    Full Text Available The use of the effective dose (the concept of which was developed for radiation protection of workers and public and the nominal risk coefficients, averaged by sex and age, to assess the radiation risks of medical exposure has some significant limitations. Age and sex distribution of the staff and the entire population may be quite different from the sex and age distribution of patients undergoing medical exposure. Moreover, the structure of the age and sex of patients may be different for various medical examinations. There are simplified methods for evaluating individual risk for patients undergoing medical exposure. The methods are based on the effective dose evaluation and those take in to account age and gender. A more accurate assessment of lifetime risk of delayed stochastic effects for health of the patient is achieved by using the organ doses and the age and gender risk factors. The aim of this work was evaluation of the lifetime risk of long-term stochastic health effects for different gender and age groups of children undergoing various radiographic investigations by using organ doses and the age and gender risk factors, and subsequent classification in accordance with generally accepted international risk scale. Data from surveys of33 X-ray units in 29 specialized pediatric health care organizations in Russia were used in the work. Organ doses and patient’s effective doses were calculated on the basis of the defined for each x-ray machine typical modes for the 12 radiographic procedures (X-ray exam of the skull, chest, cervical spine, thoracic spine, lumbar spine–all in two projections – of the abdomen and pelvis – both in one projectionusing a computer program PCXMC., Radiation risks for selected studies were estimated using the obtained organ doses and the age and gender risk factors calculated for the Russian population. The radiation risks were classified according to the international scale of the risks. It was found

  1. Determination of personnel exposures in the lower energy ranges of X-ray by photographic dosimeter

    International Nuclear Information System (INIS)

    Ha, C.W.; Kim, J.R.; Suk, K.W.

    1986-01-01

    This paper described an improved technical method required for proper evaluation of personnel exposures by means of the photographic dosimeter developed by KAERI in lower gamma or X-ray energy regions, with which response of the dosimeter varies significantly. With calibration of the dosimeter in the energy range from 30 to 300 keV, the beam spectrum was carefully selected and specified it adequately. The absorber combinations and absorber thickness used to obtain the specified X-ray spectra from a constant potential X-ray machine were determined theoretically and also experimentally. A correlation between the density and exposure for the four separate energies, such as 49 keV eff , 154 keV eff 250 keV eff and 662 keV, is experimentally determined. As a result, it can be directly evaluated the exposure from the measured response of dosimeter. (Author)

  2. Patient dose evaluations from medical X-ray exposure in Italy: an analysis of next data

    International Nuclear Information System (INIS)

    Marchetti, A.; Paganini, F.M.; Susanna, A.

    1980-01-01

    NEXT (Nationwide Evaluation of X-ray Trends) is a program for the evaluation of patient exposure in X-ray diagnostic tests. The program is aimed at reducing patient exposure by pin-pointing poor radiological techniques and improving them. CNEN (Comitato Nazionale per l'Energia Nucleare) and ISS (Istituto Superiore di Sanita) have been developing such a program in Italy since 1976. Up to now two regional administrations applied the method and regional operators collected the needed data in all the medical institutions in their areas. The results show a wide spread of values for all the parameters studied in the 12 X-ray projections selected. Gonad dose and skin entrance exposure were found to be spread over a range up to about two orders of magnitude. (H.K.)

  3. Cost Benefit Optimization of the Israeli Medical Diagnostic X-Ray Exposure

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Shlesinger, T.; Shani, G.; Kushilevsky, A.

    1999-01-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. A preliminary survey was carried out during 1997 on 3 major Israeli hospitals in order to assess the extent of exposure of the population to medical x-rays (1). The survey has found that the annual collective dose of the Israeli population to x-ray medical imaging procedures (excluding radio-therapy) is about 7,500 Man-Sv. The results of the survey were analyzed in order to. 1. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of the Israeli patients under x-ray procedures. 2. Establish a set of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. . Establish a number of basic rules to be utilized by health policy makers in Israel. Based on the ICRP-60 linear model risk assessments (2), the extent of the annual risk arising A.om the 7,500 Man-Sv medical x-ray collective dose in Israel has been found to be the potential addition of 567 cancer cases per year, 244 of which to be fatal, and a potential additional birth of 3-4 children with severe genetic damage per year. This assessment take into account the differential risk and the collective dose according to the age distribution in the Israeli exposed population, and excludes patients with chronic diseases

  4. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  5. Influence of chronic x-ray exposure on adrenal glucocorticoid function and adrenocorticocyte membrane potential

    International Nuclear Information System (INIS)

    Gorban', Je.M.; Topol'nikova, N.V.

    1998-01-01

    The peculiarities of adrenal glucocorticoid function and membrane potential (MP) of zona fasciculata adrenocorticocyte (ACC) in rats after chronic x-ray exposure was studied. The changes of adrenal glucocorticoid function caused by chronic x-ray exposure within a relatively small period of irradiation (1.5 months) are obscure and manifest themselves only at physiological load. With the prolongation of the period (8 and 15 months), more considerable inhibition of the adrenal glucocorticoid function and disturbances in the membrane mechanisms of ACC MP level regulation are revealed

  6. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  7. Micronucleus induction by repeated exposure of diagnostic X-ray on oral buccal mucosa

    International Nuclear Information System (INIS)

    Lohith Tejashvi, K.; Suchetha Kumari, N.; Shetty, Shishir Ram

    2012-01-01

    Radiography is the important diagnostic tools essential for diagnosis and planning of orthodontic treatment. X-ray is ionizing radiation which showed various effects include breaking the bond of biological molecules, inducing loss of ability of cell death, increases nuclear alterations. Micronuclei - x000D - (MN) are small chromatin bodies that appear in the cytoplasm by the - x000D - condensation of acrocentric chromosomal fragments or by whole chromosomes. This - x000D - is a sensitive indicator of genetic damage. - x000D - x000D - . To evaluate micronucleus induction by repeated exposure of diagnostic X-ray on human buccal cell. Methods: 25 patients who visiting to ABSMIDS, Department of Oral medicine and Radiology for dental checkup exposed to diagnostic X-ray more than 4 times have been selected for this study. The buccal cell for analysis was collected from the cheek mucosa by means of gentle scraping of epithelial using ice-cream sticks and placed in Buffer saline. This sample was smeared on glass slide and then fixed in methanol:glacial acetic acid (3:1). Air dried and stained with Giemsa for 15-25 minutes. Then 250 cells in each slides were analyzed under microscope and frequency of micronucleus was scored (n=4). Repeated X-ray exposed cells showed micronucleus (1.25%) and nuclear alteration (2.3%) compare to the control. Repeated X-ray exposure leads to induces detectable number of micronucleus and nuclear alterations. (author)

  8. Energy Dependence of Synchrotron X-Ray Rims in Tycho's Supernova Remnant

    Science.gov (United States)

    Tran, Aaron; Williams, Brian J.; Petre, Robert; Ressler, Sean M.; Reynolds, Stephen P.

    2015-01-01

    Several young supernova remnants exhibit thin X-ray bright rims of synchrotron radiation at their forward shocks. Thin rims require strong magnetic field amplification beyond simple shock compression if rim widths are only limited by electron energy losses. But, magnetic field damping behind the shock could produce similarly thin rims with less extreme field amplification. Variation of rim width with energy may thus discriminate between competing influences on rim widths. We measured rim widths around Tycho's supernova remnant in 5 energy bands using an archival 750 ks Chandra observation. Rims narrow with increasing energy and are well described by either loss-limited or damped scenarios, so X-ray rim width-energy dependence does not uniquely specify a model. But, radio counterparts to thin rims are not loss-limited and better reflect magnetic field structure. Joint radio and X-ray modeling favors magnetic damping in Tycho's SNR with damping lengths approximately 1-5% of remnant radius and magnetic field strengths approximately 50-400 micron G assuming Bohm diffusion. X-ray rim widths are approximately 1% of remnant radius, somewhat smaller than inferred damping lengths. Electron energy losses are important in all models of X-ray rims, suggesting that the distinction between loss-limited and damped models is blurred in soft X-rays. All loss-limited and damping models require magnetic fields approximately greater than 20 micron G, arming the necessity of magnetic field amplification beyond simple compression.

  9. Time-dependent Takagi-Taupin eikonal theory and applications in the subpicosecond manipulation of X-rays

    International Nuclear Information System (INIS)

    Adams, Bernhard W.

    2004-01-01

    A time-dependent version of the Takagi-Taupin theory of X-ray diffraction is derived in a unified space-time approach, which is particularly applicable to X-ray diffraction in a crystal that is undergoing rapid change on the subpicosecond, and even few-femtosecond, time scale. The theory is applied to the proposal of a class of X-ray optical elements for the subpicosecond manipulation of X-rays

  10. A hard x-ray prototype production exposure station at NSLS

    International Nuclear Information System (INIS)

    Johnson, E.D.; Milne, J.C.

    1997-07-01

    Exposures conducted at the NSLS R and D beamline (X-27B) for High Aspect Ratio Precision Manufacture have proven sufficiently successful that the authors are constructing a dedicated hard x-ray exposure beamline. The new beamline (X-14B) provides an exposure field ∼ 120 mm wide, three times larger than that of X-27B. The scanner is based on the hydraulic system from the X-27B program. It is optimized for planar exposures and takes advantage of the full 525 mm stroke available. Exposures of multiple substrates and masks will be possible, with the fixturing supporting mounting of substrate holders from other groups (ALS, APS, CAMD, and UW). The function of this beamline is to establish a hard x-ray exposure station where manufacturing scale protocols can be developed and ultimately exploited for production runs

  11. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

    Science.gov (United States)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael

    2017-09-01

    Purpose  Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods  Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results  The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion  In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe

  12. Energy dependence evaluation of a ZnO detector for diagnostic X-ray beam

    International Nuclear Information System (INIS)

    Valença, C.P.V.; Silveira, M.A.L.; Macedo, M.A.; Santos, M.A.

    2015-01-01

    In the last decades the international organizations of human health and radiation protection have recommended certain care for using X-ray as a diagnosis tool. The current concern is to avoid any type of radiological accident or overdose to the patient. This can be done assessing the parameters of the X-ray equipment and there are various types of detectors available for that: ionizing chamber, semiconductor devices, etc. These detectors must be calibrated so that they can be used for any energy range and such a procedure is correlated with what is called the energy dependence of the detector. In accordance with the stated requirements of IEC 61267, the standard radiation quality beams and irradiation conditions (RQRs) are the tools and techniques for calibrating diagnostic X-Ray instruments and detectors. The purpose of this work is to evaluate the behavior of the energy dependence of a detector fabricated from a zinc oxide (ZnO) nanofilm. A Pantak industrial X-ray equipment was used to generate the RQR radiation quality beams and test three ZnO detector samples. A 6430 sub-femto-ammeter, Keithley, was used to bias the ZnO detector and simultaneously perform the output readings. The results showed that the ZnO device has some increase in its sensitivity to the ionizing radiation as the X-ray effective energy decreases unlike other types of semiconductor electronic devices typically used as an X-ray detector. We can be concluded that, after calibration, the ZnO device can be used as a diagnostic X-ray detector. (author)

  13. Evaluation of the energy dependence of a zinc oxide nanofilm X-ray detector

    International Nuclear Information System (INIS)

    Valenca, C.P.V.; Silveira, M.A.L.; Macedo, M.A.; Santos, L.A.P

    2015-01-01

    International organizations of human health and radiation protection have recommended certain care for using of the X-ray as a diagnosis tool to avoid any type of radiological accident or overdose to the patient. This can be done assessing the parameters of the X-ray equipment and there are various types of detectors available for that: ionizing chamber, electronic semiconductor devices, etc. These detectors must be calibrated so that they can be used for any energy range and such a procedure is correlated with what is called the energy dependence of the detector. In accordance with the stated requirements of IEC 61267, the standard radiation quality beams and irradiation conditions (RQRs) are the tools and techniques for calibrating diagnostic X-Ray instruments and detectors. The purpose of this work is to evaluate the behavior of the energy dependence of a detector fabricated from a zinc oxide (ZnO) nanofilm. A Pantak industrial X-ray equipment was used to generate the RQR radiation quality beams and test three ZnO detector samples. A 6430 sub-femto-ammeter, Keithley, was used to bias the ZnO detector and simultaneously perform the output readings. The results showed that the ZnO device has some increase in its sensitivity to the ionizing radiation as the X-ray effective energy decreases unlike other types of semiconductor electronic devices typically used as an X-ray detector. We can conclude that the ZnO device can be used as a diagnostic X-ray detector with an appropriate calibration. (author)

  14. Digital image acquisition in the X-ray diagnostics. Its influence on the patients' exposure

    International Nuclear Information System (INIS)

    Hoberg, Bernd; Voigt, Stefan

    2012-01-01

    Radiation exposure in the classical X-ray diagnostics was continuously reduced during the past years. The annual report 2009 of the Bundesamt fuer Strahlenschutz (BfS) shows that 46% of the radiological examinations in Germany concern the skeleton, the lungs and the digestive and urogenital tract. The respective radiation dose is only 20% of the total dose of the public from X-ray diagnostic measures. Considering computerized tomography, angiography and interventional radiology, that amount to about 10% of the radiological examinations, their dose percentage reaches about 80%. Therefore, the emphasis of modern radiation protection has to be targeted to digital techniques in the future X-ray diagnostics. The authors describe digital detectors, direct and indirect digitalized image receivers, flat-panel detectors and dynamic detectors.

  15. Exposure measurement in the neighboring hospital beds during an x-ray procedure in hospitalization unit

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rafael E.; Capeleti, Felipe F.; Cabete, Henrique V., E-mail: rafael.goto@fcmsantacasasp.edu.br, E-mail: felipe.capeleti@fcmsantacasasp.edu.br, E-mail: henrique@gmpbrasil.com.br [Faculdade de Ciencias Medicas da Santa Casa Sao Paulo, SP (Brazil); GMP Consultoria em Radioprotecao e Fisica Medica e Assessoria LTDA, Sao Paulo, SP (Brazil)

    2017-11-01

    There are lots of discussion about the exposure in hospitalization units in Brazil, especially around labor legislation and economic advantages of unhealthiness. With the attention focused on hospitalized patients, there were measured the exposure in neighboring beds of the patient submitted to an X-ray procedure with a mobile X-ray system that could be used to illustrate the discussion with consistent values. The most common X-ray procedure made in hospitalization units are chests images with techniques between 70 to 120 kV and 5 to 20 mAs. The measurement was made during routine exposure and simulations using a scattering phantom with Radcal AccuPro electrometer and 1800cc ionization chamber in a private hospital and a philanthropic hospital, both in Sao Paulo, Brazil. The ionization chambers are placed at 2 meters distance of the patient exposed of both sides during the routine procedure. During the simulation, a nylon phantom of 20 centimeters thick and 30 x 30 cm² size was placed on the bed, a typical exposure technique was used and the exposure was measured surrounding the phantom at 0.6, 1.0 and 2.0 meters distance for scattered radiation characterization. Initial results showed that the neighboring exposure at about 2 meters distance from the exposed patient bed have low values, even when exposure is integrated during the length of hospital stay. Therefore, the exposure in hospitalization units are very low compared to the exams doses. (author). (author)

  16. Spectral dependence of point defect production by x rays in RbBr

    International Nuclear Information System (INIS)

    Brown, F.C.; Heald, S.M.; Jiang, D.; Brewe, D.L.; Kim, K.H.; Stern, E.A.

    1999-01-01

    F-center formation by monochromatic x rays has been studied above and below the bromine and rubidium K-absorption edges in crystals of RbBr. The x-ray beam from a double silicon crystal monochromator on an undulator at the Advanced Photon Source was used to produce these point defects, which were detected by a sensitive laser-induced luminescence method. Experiments were carried out over a wide range of monochromatic x-ray intensity, with emphasis on the nearly linear initial slope of defect formation with exposure. No significant increase in F-center formation efficiency was found upon crossing the bromine K edge, which indicates that additional Auger-cascade mechanisms do not appreciably add to the usual multiple ionization electron-hole recombination processes known to generate point defects. copyright 1999 The American Physical Society

  17. Observation of X-ray occupational exposure on psychological function of medical workers

    International Nuclear Information System (INIS)

    Gong Zhaolong; Li Xiuqin

    1988-01-01

    The present research is an attempt to study the psychological effects of long-term exposure to low-level X-ray on man. The subjects included 50 exposed people and 50 control. The battery of psychological tests consists of 10 subtests mainly involving memory and coordination ability. The results indicate that there are no statistical differences in all subtests between exposure and control group, but exposure group appears to be a little lower on most subtests about memory. With age, decline of psychological function is observed in all subtests in both groups. The subjects are further divided into three subgroups according to the number of X-ray exposed years. No statistical differences are found in all subgroups between exposure and control. Factor analysis has been made and two factors are obtained. factor 1 is mainly about speed of coordination, factor 2 is mainly about memory and attention. No statistical differences in factor scores are observed in all subgroups between exposure and control. Yet decline is found in factor 1 and factor 2 in both exposure and control groups with age. The results show that there is no significant effect of current dose level of X-ray exposure on human psychological function

  18. Measurement of the energy dependence of X-ray-induced decomposition of potassium chlorate.

    Science.gov (United States)

    Pravica, Michael; Bai, Ligang; Sneed, Daniel; Park, Changyong

    2013-03-21

    We report the first measurements of the X-ray induced decomposition of KClO3 as a function of energy in two experiments. KClO3 was pressurized to 3.5 GPa and irradiated with monochromatic synchrotron X-rays ranging in energy from 15 to 35 keV in 5 keV increments. A systematic increase in the decomposition rate as the energy was decreased was observed, which agrees with the 1/E(3) trend for the photoelectric process, except at the lowest energy studied. A second experiment was performed to access lower energies (10 and 12 keV) using a beryllium gasket; suggesting an apparent resonance near 15 keV or 0.83 Ǻ maximizing the chemical decomposition rate. A third experiment was performed using KIO3 to ascertain the anionic dependence of the decomposition rate, which was observed to be far slower than in KClO3, suggesting that the O-O distance is the critical factor in chemical reactions. These results will be important for more efficiently initiating chemical decomposition in materials using selected X-ray wavelengths that maximize decomposition to aid useful hard X-ray-induced chemistry and contribute understanding of the mechanism of X-ray-induced decomposition of the chlorates.

  19. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  20. Update of diagnostic medical and dental x-ray exposures in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Sorop, Ioana; Mossang, Daniela; Dadulescu, Elena [Radiation Hygiene Laboratory of Public Health Authority Dolj, 2, Constantin Lecca Street, Craiova (Romania); Iacob, Mihai Radu [University ' Alexandru Ioan Cuza' , 11, Carol I Street, 700506, Iasi (Romania); Iacob, Olga [Institute of Public Health, 14, Victor Babes Street, 700465 Iasi (Romania)], E-mail: danamossang@sanpubdj.ro

    2008-12-15

    This national study, the third in the last 15 years, updates the magnitude of medical radiation exposure from conventional x-ray examinations, in order to optimise the radiological protection to the population in a cost-effective manner. Effective doses from diagnostic radiology were estimated for adult and paediatric patients undergoing the 20 most important types of x-ray examination. Data were collected from 179 x-ray departments, selected by their annual workload, throughout the country. Estimates were made using two dosimetric quantities: entrance surface dose, derived from the absorbed dose in air measured by simulation of radiographic examinations, and dose-area product, measured during fluoroscopic examinations performed on adult and paediatric patients. Conversion coefficients to effective dose of the UK National Radiological Protection Board (NRPB) have been used in all calculations. The effective dose per patient from all medical x-ray examinations was 0.74 mSv and the resulting annual collective effective dose was 6930 man Sv, with annual effective dose per caput of 0.33 mSv. The current size of population exposure from diagnostic radiology is lower than the previous one by 40%, but could be about 30% higher by taking into account the estimated contribution from computed tomography (CT) procedures.

  1. Radiation exposure to chest X-rays in the neonatal nursery

    International Nuclear Information System (INIS)

    Takeuchi, Toshio; Itabashi, Kazuo; Kawaguchi, Shigeru; Suzuka, Takahisa; Okuyama, Kazuo

    1989-01-01

    To measure how much very low birth-weight infants are exposed to chest X-rays during nursery, skin doses were calculated using phantoms under the same condition as that used in chest X-rays. Skin doses obtained were multiplied by the number of X-rays performed in 86 very low birth-weight infants (mean birth weight+-SD, 1163.0+-232.8 g; mean gestational age+-SD, 29.3+-3.0 week). Exposure doses per film ranged from 4.9 to 14.4 mR, with a mean dose of 6.1+-2.0 mR. Exposure doses per neonate ranged from 6.3 to 794.3 mR, with a mean dose of 170.4+-151.5 mR. The number of films per neonate ranged from one to 107, with a mean of 28.0+-24.9. Eighty-seven percent of X-rays were performed when the body weight was 1,500 g or less. Fourteen patients received 300 mR or more that may be the potential dose of radiation effects. (Namekawa, K)

  2. Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

    Science.gov (United States)

    Benyo, Theresa L.; Steinetz, Bruce M.; Hendricks, Robert C.; Martin, Richard E.; Forsley, Lawrence P.; Daniels, Christopher C.; Chait, Arnon; Pines, Vladimir; Pines, Marianna; Penney, Nicholas; hide

    2017-01-01

    Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 µA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4s confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

  3. Note: Theoretical study on the gas pressure dependence of x-ray yield in TE111 cavity based electron cyclotron resonance x-ray source

    International Nuclear Information System (INIS)

    Selvakumaran, T. S.; Sen, Soubhadra; Baskaran, R.

    2014-01-01

    Adopting Langevin methodology, a pressure dependent frictional force term which represents the collisional effect is added to the Lorentz equation. The electrons are assumed to be starting from the uniformly distributed co-ordinates on the central plane. The trajectory of each electron is numerically simulated by solving the modified Lorentz equation for a given pressure. The Bremsstrahlung x-ray energy spectrum for each electron crossing the cavity wall boundary is obtained using the Duane-Hunt law. The total x-ray yield is estimated by adding the spectral contribution of each electron. The calculated yields are compared with the experimental results and a good agreement is found

  4. Shorter exposures to harder X-rays trigger early apoptotic events in Xenopus laevis embryos.

    Directory of Open Access Journals (Sweden)

    JiaJia Dong

    Full Text Available BACKGROUND: A long-standing conventional view of radiation-induced apoptosis is that increased exposure results in augmented apoptosis in a biological system, with a threshold below which radiation doses do not cause any significant increase in cell death. The consequences of this belief impact the extent to which malignant diseases and non-malignant conditions are therapeutically treated and how radiation is used in combination with other therapies. Our research challenges the current dogma of dose-dependent induction of apoptosis and establishes a new parallel paradigm to the photoelectric effect in biological systems. METHODOLOGY/PRINCIPAL FINDINGS: We explored how the energy of individual X-ray photons and exposure time, both factors that determine the total dose, influence the occurrence of cell death in early Xenopus embryo. Three different experimental scenarios were analyzed and morphological and biochemical hallmarks of apoptosis were evaluated. Initially, we examined cell death events in embryos exposed to increasing incident energies when the exposure time was preset. Then, we evaluated the embryo's response when the exposure time was augmented while the energy value remained constant. Lastly, we studied the incidence of apoptosis in embryos exposed to an equal total dose of radiation that resulted from increasing the incoming energy while lowering the exposure time. CONCLUSIONS/SIGNIFICANCE: Overall, our data establish that the energy of the incident photon is a major contributor to the outcome of the biological system. In particular, for embryos exposed under identical conditions and delivered the same absorbed dose of radiation, the response is significantly increased when shorter bursts of more energetic photons are used. These results suggest that biological organisms display properties similar to the photoelectric effect in physical systems and provide new insights into how radiation-mediated apoptosis should be understood and

  5. Childhood cancer after prenatal exposure to diagnostic X-ray examinations in Britain

    International Nuclear Information System (INIS)

    Mole, R.H.

    1990-01-01

    Detailed data were provided by the Oxford Survey of Childhood Cancer OSCC on deaths from childhood cancer in Britain after irradiation of the fetus during diagnostic radiology of the mother. In each age group at death, 0-5, 6-9 and 10-15 years, excess cancer deaths decreased suddenly for births in and after 1958. A major factor was concerted action initiated in 1956 to reduce radiation exposure of fetal gonads for fear of genetic hazards. Dose reduction was achieved during 1957 and early 1958 by reducing the rising rate of obstetric radiography and by virtually abandoning pelvimetry as that had been understood. In the 1970s the rate of X-raying increased again and so did cancer risk but not significantly. Direct evidence that diagnostic X-rays can cause childhood cancer is the similar excess rate per X-ray in twins and singleton births when X-raying rate is 5-6 times higher in twins. (author)

  6. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  7. The X-Ray Luminosity Functions of Field Low-Mass X-Ray Binaries in Early-Type Galaxies: Evidence for a Stellar Age Dependence

    Science.gov (United States)

    Lehmer, B. D.; Berkeley, M.; Zezas, A.; Alexander, D. M.; Basu-Zych, A.; Bauer, F. E.; Brandt, W. N.; Fragos, T.; Hornschemeier, A. E.; Kalogera, V.; hide

    2014-01-01

    We present direct constraints on how the formation of low-mass X-ray binary (LMXB) populations in galactic fields depends on stellar age. In this pilot study, we utilize Chandra and Hubble Space Telescope (HST) data to detect and characterize the X-ray point source populations of three nearby early-type galaxies: NGC 3115, 3379, and 3384. The luminosity-weighted stellar ages of our sample span approximately equal to 3-10 Gyr. X-ray binary population synthesis models predict that the field LMXBs associated with younger stellar populations should be more numerous and luminous per unit stellar mass than older populations due to the evolution of LMXB donor star masses. Crucially, the combination of deep Chandra and HST observations allows us to test directly this prediction by identifying and removing counterparts to X-ray point sources that are unrelated to the field LMXB populations, including LMXBs that are formed dynamically in globular clusters, Galactic stars, and background AGN/galaxies. We find that the "young" early-type galaxy NGC 3384 (approximately equals 2-5 Gyr) has an excess of luminous field LMXBs (L(sub x) approximately greater than (5-10) × 10(exp 37) erg s(exp -1)) per unit K-band luminosity (L(sub K); a proxy for stellar mass) than the "old" early-type galaxies NGC 3115 and 3379 (approximately equals 8-10 Gyr), which results in a factor of 2-3 excess of L(sub X)/L(sub K) for NGC 3384. This result is consistent with the X-ray binary population synthesis model predictions; however, our small galaxy sample size does not allow us to draw definitive conclusions on the evolution field LMXBs in general. We discuss how future surveys of larger galaxy samples that combine deep Chandra and HST data could provide a powerful new benchmark for calibrating X-ray binary population synthesis models.

  8. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, G. (Orvostudomanyi Egyetem, Szeged (Hungary). Orvosbiologiai Intezet)

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners.

  9. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    International Nuclear Information System (INIS)

    Szemere, G.

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners. (author)

  10. Hospital and clinic survey estimates of medical x-ray exposures in Hiroshima and Nagasaki, (1)

    International Nuclear Information System (INIS)

    Sawada, Shozo; Land, C.E.; Otake, Masanori; Russell, W.J.; Takeshita, Kenji.

    1980-11-01

    All large hospitals and 40% of the small hospitals and clinics in Hiroshima and Nagasaki cities were surveyed for the X-ray examinations they performed during a 2-week period in 1974. The frequency and type of X-ray examinations received by members of the RERF Adult Health Study (AHS) and the RERF Life Span Study (LSS) extended, excluding AHS (Non-AHS), were compared with the general population in each city. Radiologic exposures of patients at hospitals and clinics were most frequent among the general populations. The number of patients, examinations, and exposures per caput per year in each population were estimated. Since the age distribution differed among the three populations, comparisons were made only after correcting for age. On a per caput per year basis exposure frequency was relatively high in the AHS and low in the general populations, a reflection of the greater number of patients in the AHS than in the general populations. Non-AHS males in Nagasaki had a higher X-ray examination rate than did the AHS subjects. The others in the Non-AHS did not differ appreciably from the general populations. There was no difference among these groups according to body sites examined. (author)

  11. Hygiene implications associated with x-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients, then a skeleton encased in plastic, was instrumented with LiF thermoluminescent dosimeters to quantify radiation exposures delivered from full-face diagnostic dental x-rays. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices

  12. DEPENDENCE OF X-RAY BURST MODELS ON NUCLEAR REACTION RATES

    Energy Technology Data Exchange (ETDEWEB)

    Cyburt, R. H.; Keek, L.; Schatz, H. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Amthor, A. M. [Department of Physics and Astronomy, Bucknell University, Lewisburg, PA 17837 (United States); Heger, A.; Meisel, Z.; Smith, K. [Joint Institute for Nuclear Astrophysics (JINA), Michigan State University, East Lansing, MI 48824 (United States); Johnson, E. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States)

    2016-10-20

    X-ray bursts are thermonuclear flashes on the surface of accreting neutron stars, and reliable burst models are needed to interpret observations in terms of properties of the neutron star and the binary system. We investigate the dependence of X-ray burst models on uncertainties in (p, γ ), ( α , γ ), and ( α , p) nuclear reaction rates using fully self-consistent burst models that account for the feedbacks between changes in nuclear energy generation and changes in astrophysical conditions. A two-step approach first identified sensitive nuclear reaction rates in a single-zone model with ignition conditions chosen to match calculations with a state-of-the-art 1D multi-zone model based on the Kepler stellar evolution code. All relevant reaction rates on neutron-deficient isotopes up to mass 106 were individually varied by a factor of 100 up and down. Calculations of the 84 changes in reaction rate with the highest impact were then repeated in the 1D multi-zone model. We find a number of uncertain reaction rates that affect predictions of light curves and burst ashes significantly. The results provide insights into the nuclear processes that shape observables from X-ray bursts, and guidance for future nuclear physics work to reduce nuclear uncertainties in X-ray burst models.

  13. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    International Nuclear Information System (INIS)

    Mergel, E.; Feige, S.; Haeusler, U.

    2007-01-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  14. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  16. Radiation exposure of holding personnel involved in veterinary X-ray diagnosis

    International Nuclear Information System (INIS)

    Rothe, W.

    1977-01-01

    An account is given of radiation protection in the context of X-ray examination of small and big animals on the premises of seven reviewed veterinary centres. Also reported are the dosimetric results obtained from holding personnel involved in X-ray diagnosis of 319 big and 4,047 small animals. Infringement of valid regulations was quite often observed, in that animals are held in position in an inadequate way and by unauthorised persons. The measured results, however, have shown that the radiation exposure of vocationally exposed persons can be kept far below the maximum permissible equivalent doses, provided that all applicable rules of radiation protection are observed by those on duty. (author)

  17. Exposure assessment of neonates in israel to x-ray radiation during hospitalization at neonatal intensive care unit

    International Nuclear Information System (INIS)

    Datz, H.

    2005-03-01

    Nowadays nearly 10% of all births in western countries are premature. In the last decade, there has been an increase of 45% in the number of neonates that were born in Israel. At the same time, the survival of neonates, especially those with very low birth weight, VLBW, (less than 1,500 gr), has increased dramatically. Diagnostic radiology plays an important role in the assessment and treatment of neonates requiring intensive care. During their prolonged and complex hospitalization, these infants are exposed to multiple radiographic examinations involving X-ray radiation. The extent of the examinations that the infant undergoes depends on its birth weight, gestational age and its medical problems, where most of the treatment effort is focused especially on VLBW neonates. Most of the diagnostic X-ray examinations taken during the hospitalization of neonates in the neonatal intensive care unit (NICU) consist of imaging of the respiratory and gastrointestinal systems, namely, the chest and abdomen. The imaging process is done using mobile X-ray units located at the NICUs. Due to their long hospitalization periods and complex medical condition, all neonates, and neonates with VLBW in particular, are exposed to a much higher level of diagnostic radiation, compared to normal newborns. The goal of this research was to assess the extent of the exposure of neonates in Israel to X-ray radiation during their hospitalization at the neonatal intensive care unit. Five NICUs, located at different geographical zones in Israel and treating 20% of all newborns in Israel every year, participated in this research. The research was conducted in three phases: Phase I: Collection of information on radiographic techniques and exposure parameters (e.g. kV, mAs, focus to skin distance (FSD), examination borders). 499 X-ray examinations (from 157 neonates) were evaluated for necessary and unnecessary exposure of the neonate's organs to X-ray radiation during these examinations. Phase II

  18. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  19. Change of energy dependence for X-rays of photodiode detector

    International Nuclear Information System (INIS)

    Silva, M.F. da; Freitas, L.C. de

    1992-01-01

    The energy dependence of photodiode Siemens SFH-206 for X-rays beams of 24 kV to 50 kV was studied and compared with the ionization chamber of parallel plates. The photodiode presented 450% of maxim change response for the energy band studied. A study was made, using aluminium, acrylic, mylar aluminized and mylar graphitized filters and showed that the two last reduce this maxim change response to 101% and 108%, respectively. (C.G.C.)

  20. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    International Nuclear Information System (INIS)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S

    2006-01-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process

  1. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-dong, Daejeon (Korea, Republic of)

    2006-04-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process.

  2. A synchrotron-based X-ray exposure station for radiation biology experiments

    International Nuclear Information System (INIS)

    Thompson, A.C.; Blakely, E.A.; Bjornstad, K.A.; Chang, P.Y.; Rosen, C.J.; Schwarz, R.I.

    2007-01-01

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 μm). A series of experiments have been done with a four-well slide where a stripe (100 μm widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments

  3. A synchrotron-based X-ray exposure station for radiation biology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, A.C. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)], E-mail: acthompson@lbl.gov; Blakely, E.A.; Bjornstad, K.A. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); Chang, P.Y. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); SRI International, Menlo Park, CA (United States); Rosen, C.J.; Schwarz, R.I. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)

    2007-11-11

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 {mu}m). A series of experiments have been done with a four-well slide where a stripe (100 {mu}m widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments.

  4. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    Science.gov (United States)

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  5. X-ray diagnostic study on the optimization of digital radiography in dentistry. Optimal exposure conditions for X-ray CCD sensor

    International Nuclear Information System (INIS)

    Hakata, Toshifumi

    2002-01-01

    The purpose of this research is to reduce the patient dose by optimization of irradiation conditions of an X-ray CCD sensor in intra-oral digital radiography. The X-ray diagnosis was divided into two, high quality-of-image diagnosis and low quality-of-image diagnosis, and it optimized by using the exposure of necessary minimum for each. The image quality of CCD was evaluated using the signal-to-noise ratio (SNR) in order to estimate the influence of irradiation conditions. The dose based on CCD maker setting value was set up so that the highest quality of image might be obtained mostly. In low quality-of-image diagnosis, even if it reduced the dose to 13.2% of standard irradiation, SNR was 40% and interpretation was possible. In high quality-of-image diagnosis, even if it reduces the dose to 49% of standard irradiation, SNR remained 80% and there were few differences of the image with a standard. A study of the digital X-ray examination taken at the dental clinic showed high quality-of-image diagnosis was 69% and low quality-of-image one was 31%. When this optimization was performed, it was presumed that reduction of about 62% of the dose is possible. (author)

  6. ABCC-JNIH adult health study Hiroshima and Nagasaki 1961 exposure to medical x-ray. Preliminary survey

    Energy Technology Data Exchange (ETDEWEB)

    Ishimaru, Toranosuke; Russell, W J

    1962-05-16

    A survey was conducted for three months among subjects seen in the medical clinics of ABCC, Hiroshima and Nagasaki, to determine the extent of medical x-ray received in ABCC and other hospitals and clinics. Emphasis was chiefly methodological to prepare for later studies designed to evaluate the contribution of medical x-ray to total radiation dose received by survivors of the atomic bombings and controls. The frequency, the institution in which the subject received x-ray, as well as the types of exposure were the prime considerations in the survey. The data were analyzed for each city by sex, age, and exposure status. 2 references, 5 figures, 11 tables.

  7. Optimization of exposure factors for X-ray radiography non-destructive testing of pearl oyster

    Science.gov (United States)

    Susilo; Yulianti, I.; Addawiyah, A.; Setiawan, R.

    2018-03-01

    One of the processes in pearl oyster cultivation is detecting the pearl nucleus to gain information whether the pearl nucleus is still attached in the shell or vomited. The common tool used to detect pearl nucleus is an X-ray machine. However, an X-ray machine has a drawback that is the energy used is higher than that used by digital radiography. The high energy make the resulted image is difficult to be analysed. One of the advantages of digital radiography is the energy used can be adjusted so that the resulted image can be analysed easily. To obtain a high quality of pearl image using digital radiography, the exposure factors should be optimized. In this work, optimization was done by varying the voltage, current, and exposure time. Then, the radiography images were analysed using Contrast to Noise Ratio (CNR). From the analysis, it can be determined that the optimum exposure factors are 60 kV of voltage, 16 mA of current, and 0.125 s of exposure time which result in CNR of 5.71.

  8. Radiation exposure of the Yazd Population from medical conventional X-ray examinations

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Zare, M. H.; Dashti, M. H.

    2007-01-01

    Radiation dose knowledge through X-ray examinations and their distribution in Iran provides useful guidance on patient dose reduction. The results of the entrance skin dose (ESD s ) of five common radiographs in all radiology centers in Yazd province were reported in our previous study (2003). In the present study we have evaluated the collective effective dose of conventional X-ray examinations, as well as the annual per caput of Yazd population.Materials and Methods: The annual frequencies of 18 different types of conventional radiology examinations during April 2005 to March 2006 were recorded from all 35 radiology centers in Yazd province. The exposure conditions consisted of kVp, mAs, and Focus surface distance (FSD) of the examinations for the mode of exposure in each X-ray unit. 620 ESD were measured by diode dosimeter in 35 hospitals and clinics. The real exposure kVp for each radiology unit was measured by a Molt-0-Meter. The conversion coefficient (effective dose - ESD ratio) for each radiology examination was determined by using SR262 tables. Finally, the patients' effective dose was calculated by multiplying the conversion factor to the ESD. Results: The patients' annual collective effective dose due to the conventional radiology examinations was 31.159 man-Sv (0.03 mSv per inhabitant). The frequency of examinations was 311813 i.e. 0.36 examinations per head of the population for one year. Conclusion: According to our findings, the effective per caput dose seems to be optimally relative to HCL-II countries, which may be due to low mean effective dose that could obscure high examination frequency. The number of radiology conventional examinations and frequency of radiologist per1000 population of Yazd was more and lower than HCL-II countries respectively. Thus the justification of radiography requests in this province must be revised

  9. ANATOMICAL DISPOSITION OF CARPAL BONES OF GOLDEN RETRIEVER DOG BY X-RAY EXPOSURE

    Directory of Open Access Journals (Sweden)

    R. Mandal

    2012-07-01

    Full Text Available The present study was conducted to know the general disposition of bones in carpal region of experimental dogs by X-ray study with an objective that the findings will facilitate to have an in-depth knowledge about the proper positioning of the carpal bones for surgical management of fractures and different types of bone deformities in dogs. In the present study, the anatomical disposition and arrangement pattern of carpal bones playing a pivotal role in providing the structural conformity in the limbs of Golden Retriever dog has been thoroughly confirmed by Xray exposure.

  10. Radiation exposure of the UK population from medical and dental x-ray examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.

    2002-03-01

    Knowledge of recent trends in the radiation doses from x-ray examinations and their distribution for the UK population provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimise the protection of the population in a cost-effective manner. In this report, the results of a recent survey of the frequency of medical and dental x-ray examinations in the UK and contemporary data on the radiation doses typically received by patients, are used to assess trends in the extent and the pattern of the population exposure. Individual patient doses, expressed in terms of the effective dose, range from a few microsieverts for simple radiographic examinations of the teeth, limbs or chest to tens of millisieverts for prolonged fluoroscopic procedures or some computed tomography (CT) examinations. A total of about 41.5 million medical and dental x-ray examinations are now conducted each year in the UK (0.70 examination per head of population) resulting in an annual per caput effective dose of 330 μSv. This is not significantly different from the previous rough estimate of 350 μSv for 1991. However, over the last ten years CT has more than doubled its contribution and is now responsible for 40% of the total dose to the population from medical x-rays. In contrast, the contribution from conventional radiographic and fluoroscopic examinations has nearly halved to about 44%. Interventional and angiographic procedures together contribute the remaining 16%. The annual per caput dose of 330 μSv is low in comparison with other countries having similarly developed systems of health care. This is due to both a lower frequency of x-ray examinations per head of population and generally lower doses in the UK than in other developed countries. However, the much increased contributions of CT, angiography and interventional procedures to the UK population dose indicate an urgent need to develop radiation protection and optimisation activities for

  11. Exposure to Low-Dose X-Ray Radiation Alters Bone Progenitor Cells and Bone Microarchitecture.

    Science.gov (United States)

    Lima, Florence; Swift, Joshua M; Greene, Elisabeth S; Allen, Matthew R; Cunningham, David A; Braby, Leslie A; Bloomfield, Susan A

    2017-10-01

    Exposure to high-dose ionizing radiation during medical treatment exerts well-documented deleterious effects on bone health, reducing bone density and contributing to bone growth retardation in young patients and spontaneous fracture in postmenopausal women. However, the majority of human radiation exposures occur in a much lower dose range than that used in the radiation oncology clinic. Furthermore, very few studies have examined the effects of low-dose ionizing radiation on bone integrity and results have been inconsistent. In this study, mice were irradiated with a total-body dose of 0.17, 0.5 or 1 Gy to quantify the early (day 3 postirradiation) and delayed (day 21 postirradiation) effects of radiation on bone microarchitecture and bone marrow stromal cells (BMSCs). Female BALBc mice (4 months old) were divided into four groups: irradiated (0.17, 0.5 and 1 Gy) and sham-irradiated controls (0 Gy). Micro-computed tomography analysis of distal femur trabecular bone from animals at day 21 after exposure to 1 Gy of X-ray radiation revealed a 21% smaller bone volume (BV/TV), 22% decrease in trabecular numbers (Tb.N) and 9% greater trabecular separation (Tb.Sp) compared to sham-irradiated controls (P X-rays, whereas osteoclastogenesis was enhanced. A better understanding of the effects of radiation on osteoprogenitor cell populations could lead to more effective therapeutic interventions that protect bone integrity for individuals exposed to low-dose ionizing radiation.

  12. Effect of medical x-ray exposure on subsequent reproductive outcomes in scoliosis patients

    International Nuclear Information System (INIS)

    Visscher, W.A.

    1987-01-01

    A retrospective cohort study was done which was designed to assess the effects of medical x-ray exposure on cancer incidence among scoliosis patients. Although the primary purpose of the study was to assess cancer incidence, a secondary goal was to investigate whether diagnostic x-ray exposure is related to adverse reproductive events in the female subjects. A series of case-control analyses were done which were designed to assess these effects. Radiation exposure was measured both by total films received and by an estimate of the number of films received and by an estimate of the number of films which involved ovarian irradiation. Radiation appeared to increase a woman's risk of any adverse event in the overall analysis and her risk of a premature or low birth weight infant in the separate analyses. Radiation did not appear to be related to spontaneous abortion, complications of pregnancy or delivery or birth defects, although the results of the pregnancy complications analysis was suggestive

  13. A survey of medical exposure during X-ray diagnosis in Aomori

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    The purpose of this project was to survey medical exposure doses in Aomori Prefecture and compare them with guidance levels for X-ray diagnosis. A questionnaire survey on X-ray diagnosis was conducted at the main medical institutions in the prefecture. The questionnaire asked about technical conditions, and replies were obtained from 72.2% of the 79 institutions. The medical exposure doses (entrance surface doses) were calculated from the results of the questionnaires by the modified numerical dose determination (NDD) method. The distribution of the entrance surface doses at each site was calculated as the 1st quartile, median, 3rd quartile, average, standard deviation, maximum value and minimum value, by the quartile method. The distribution of exposed doses at each site showed a similar pattern with that of the national distribution. Some institutions used higher doses than the Japanese proposed guidance levels and International Atomic Energy Agency (IAEA) guidance levels. Re-assessment of radiographic conditions and photosensitive materials is needed to reduce exposure doses. (K.H.)

  14. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  15. SU-E-I-52: Effect of Various X-Ray Beam Qualities On the Exposure Index

    International Nuclear Information System (INIS)

    Yasumatsu, S; Iwase, K; Shimizu, Y; Tanaka, N; Morishita, J

    2015-01-01

    Purpose: The exposure index (EI) proposed by the International Electrotechnical Commission (IEC) 62494-1 is expected to be utilized as a standard dose index by every manufacturer. The IEC recommended the usage of RQA5 for the EI. However, X-ray beam qualities, particularly in clinical practices, vary depending on the examination objects and exposure conditions, including usage of anti-scatter grids. We investigated the effects of the X-ray beam qualities other than RQA5 on the EI. Methods: The Xray beam qualities of RQA3, 5, 7, and 9 in IEC 61267 Ed. 1.0 were adopted in a computed radiography system. A uniform exposure without objects was performed to measure the exposure indicators (S values) and air kerma (K). The relational equations between the S values and K were derived for the determination of the EI values. The EI values for RQA3, 7, and 9 were compared to those for RQA5 at the fixed S values of 100, 200, 400, and 600. Finally, the half-value layers (HVLs) using four grids (ratio 6:1, 8:1, 10:1, and 12:1) for the RQA5 X-ray were compared to those with RQA3–9. Results: The EI values for RQA3, 7, and 9 were up to 35.3%, 11.8%, and 38.7% higher, respectively, than that for RQA5 at the S value of 600. The HVLs without grids and with various grids for RQA5 were 6.85 mm Al. and in the range of 6.94–7.29 mm Al. (ΔHVL: up to 0.44 mm Al.), respectively. This variation in the HVLs with grids was smaller than that observed for RQA3–9 (ΔHVL: 2.0–7.5 mm Al.). Conclusion: Although the usage of grids may not greatly affect the EI, the X-ray beam quality for the determination of the EI cannot be ignored in the clinical evaluation of the dose index

  16. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    Energy Technology Data Exchange (ETDEWEB)

    Mergel, E.; Feige, S. [Gesellschaft fuer Anlagen- und Reaktorsicherheit mbH (GRS) (Germany); Haeusler, U. [Bundesamt fuer Strahlenschutz (BfS), Salzgitter (Germany)

    2007-07-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  17. Determining misorientation of graphite grains from the angular dependence of X-ray emission spectra

    International Nuclear Information System (INIS)

    Belavin, V. V.; Okotrub, A. V.; Bulusheva, L. G.; Kotosonov, A. S.; Vyalykh, D. V.; Molodtsov, S. L.

    2006-01-01

    Angular-resolved X-ray absorption spectra were measured for pyrolytic graphite samples of various quality. A new approach to determining the misorientation of graphite grains in polycrystalline samples is proposed, which is based on calculations of the angular dependence of the relative intensity of a peak corresponding to the π* state for a normal distribution of grains. The experimental values are used to construct theoretical angular dependences using partial densities of the π* and σ* states determined from the nonempirical calculations for graphite

  18. Radiological protection in X-ray diagnosis: How to minimize the patient exposure in X-ray diagnosis

    International Nuclear Information System (INIS)

    Araujo, A.M.C. de.

    1986-01-01

    The principles involved in the radiation protection and the radiographic process are discussed. An adequate systematic work is presented, to achieve the main goal of the Radiation Protection that is, to irradiate the patient and the staff with lowest possible exposure. (M.A.C.) [pt

  19. Modeling the focusing efficiency of lobster-eye optics for image shifting depending on the soft x-ray wavelength.

    Science.gov (United States)

    Su, Luning; Li, Wei; Wu, Mingxuan; Su, Yun; Guo, Chongling; Ruan, Ningjuan; Yang, Bingxin; Yan, Feng

    2017-08-01

    Lobster-eye optics is widely applied to space x-ray detection missions and x-ray security checks for its wide field of view and low weight. This paper presents a theoretical model to obtain spatial distribution of focusing efficiency based on lobster-eye optics in a soft x-ray wavelength. The calculations reveal the competition mechanism of contributions to the focusing efficiency between the geometrical parameters of lobster-eye optics and the reflectivity of the iridium film. In addition, the focusing efficiency image depending on x-ray wavelengths further explains the influence of different geometrical parameters of lobster-eye optics and different soft x-ray wavelengths on focusing efficiency. These results could be beneficial to optimize parameters of lobster-eye optics in order to realize maximum focusing efficiency.

  20. Determination of existing exposure level of population during X ray investigations

    International Nuclear Information System (INIS)

    Tselinov, N.V.; Kudritskij, Yu.K.

    1978-01-01

    The distribution of X ray procedures among 500 inhabitants of the city of Vorkuta in 1975 is studied. Data on the distribution of the subjects by age group and type of X ray procedure are presented. The results obtained broaden the existing concepts on hygienic importance of radiation received by the population of the country during X ray studies. It is proposed that these results be used in developing methods for standardizing X ray procedures

  1. Temperature- and density-dependent x-ray scattering in a low-Z plasma

    International Nuclear Information System (INIS)

    Brown, R.T.

    1976-06-01

    A computer program is described which calculates temperature- and density-dependent differential and total coherent and incoherent x-ray scattering cross sections for a low-Z scattering medium. Temperature and density are arbitrary within the limitations of the validity of local thermodynamic equilbrium, since ionic populations are calculated under this assumption. Scattering cross sections are calculated in the form factor approximation. The scattering medium may consist of any mixure of elements with Z less than or equal to 8, with this limitation imposed by the availability of atomic data

  2. DNA Topoisomerase-I Inhibition due to Exposure to X-Rays

    International Nuclear Information System (INIS)

    Daudee, R.; Gonen, R.; German, U.; Orion, I.; Priel, E.

    2014-01-01

    In events such as radiological terrorism, accidents involving radioactive materials and occupational exposures, there is a great need to identify exposures to relatively low radiation levels. In many situations, the evaluation of radiation doses is not possible using physical dosimeters as they are not worn, and it is desirable to achieve this based on sensitive biomarkers (1, 2, 3). DNA Topoisomerase-I (Topo-I) is an essential nuclear enzyme that is responsible for the topological state of the DNA. The enzyme is involved in a variety of DNA transactions, including replication, transcription, recombination and DNA repair (4,5). The aim of the present work was to investigate the influence of X-ray radiation on the catalytic activity of this enzyme, and to evaluate its applicability as a biological dosimeter

  3. Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure

    Science.gov (United States)

    Stanton, Ian N.; Belley, Matthew D.; Nguyen, Giao; Rodrigues, Anna; Li, Yifan; Kirsch, David G.; Yoshizumi, Terry T.; Therien, Michael J.

    2014-04-01

    Eu- and Li-doped yttrium oxide nanocrystals [Y2-xO3 Eux, Liy], in which Eu and Li dopant ion concentrations were systematically varied, were developed and characterized (TEM, XRD, Raman spectroscopic, UV-excited lifetime, and ICP-AES data) in order to define the most emissive compositions under specific X-ray excitation conditions. These optimized [Y2-xO3 Eux, Liy] compositions display scintillation responses that: (i) correlate linearly with incident radiation exposure at X-ray energies spanning from 40-220 kVp, and (ii) manifest no evidence of scintillation intensity saturation at the highest evaluated radiation exposures [up to 4 Roentgen per second]. For the most emissive nanoscale scintillator composition, [Y1.9O3; Eu0.1, Li0.16], excitation energies of 40, 120, and 220 kVp were chosen to probe the dependence of the integrated emission intensity upon X-ray exposure-rate in energy regimes having different mass-attenuation coefficients and where either the photoelectric or the Compton effect governs the scintillation mechanism. These experiments demonstrate for the first time for that for comparable radiation exposures, when the scintillation mechanism is governed by the photoelectric effect and a comparably larger mass-attenuation coefficient (120 kVp excitation), greater integrated emission intensities are recorded relative to excitation energies where the Compton effect regulates scintillation (220 kVp) in nanoscale [Y2-xO3 Eux] crystals. Nanoscale [Y1.9O3; Eu0.1, Li0.16] (70 +/- 20 nm) was further exploited as a detector material in a prototype fiber-optic radiation sensor. The scintillation intensity from the [Y1.9O3; Eu0.1, Li0.16]-modified, 400 μm sized optical fiber tip, recorded using a CCD-photodetector and integrated over the 605-617 nm wavelength domain, was correlated with radiation exposure using a Precision XRAD 225Cx small-animal image guided radiation therapy (IGRT) system. For both 80 and 225 kVp energies, this radiotransparent device recorded

  4. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.

    Science.gov (United States)

    Rampado, O; Garelli, E; Deagostini, S; Ropolo, R

    2006-06-07

    There is a growing interest in Gafchromic films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.

  5. Dose and energy dependence of response of Gafchromic (registered) XR-QA film for kilovoltage x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Rampado, O; Garelli, E; Deagostini, S; Ropolo, R [Struttura Complessa fisica Sanitaria, Azienda Ospedaliera San Giovanni Battista, Corso Bramante 88, 10126 Turin (Italy)

    2006-06-07

    There is a growing interest in Gafchromic (registered) films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.

  6. Dependence of the K x-ray energy on the mode of excitation

    International Nuclear Information System (INIS)

    Wang, K.C.; Boehm, F.; Hahn, A.A.; Vogel, P.

    1977-01-01

    The energy shifts in the Ta K x rays resulting from the K-capture of 181 W, fluorescence of Ta, and β - decay of 181 Hf followed by internal conversion in 181 Ta are reported. Both W metal and WO 3 on one hand, and Ta metal and Ta 2 O 5 on the other hand, were used. Comparison of the K x-ray energies of the K-capture sources 153 Gd (Eu x rays) and 175 Hf (Lu x rays) and the corresponding fluorescence sources was also made. Various effects which may influence the K x-ray energies are discussed. 9 references

  7. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  8. Medical management of severe local radiation injury after acute X-ray exposure

    International Nuclear Information System (INIS)

    Bushmanov, A.; Nadezhina, N.; Kretov, A.

    2008-01-01

    Medical management during acute period in a case of severe local radiation injury after acute X-ray exposure includes 3 stages. During the fist stage patient got conservative treatment according to the common pathogenetic mechanisms of LRI (dis aggregating therapy, stimulation of regeneration, dis intoxication therapy, antibiotic therapy, pain relief therapy, Local anti-burn therapy-specific non-adhesive bandage with antiseptic and anti-burn medicaments); estimation of severity, deepness and area of injury by clinical picture and dates of instrumental methods of examining; defining necessity and volume of surgical treatment; preparing arrangements for surgical treatment. This stage ends with forming of demarcation line of a very hard severity of a Local Radiation Injure. The second stage includes necrectomy of the area of a very hard severity with microsurgical plastic by re vascularized flap and auto dermoplastic. The third stage - adaptation of re vascularized flap and total epithelization of injured area. (author)

  9. H and D curves of screen--film systems: factors affecting their dependence on x-ray energy

    International Nuclear Information System (INIS)

    Vyborny, C.J.

    1979-01-01

    The sensitometric properties of radiographic screen--film systems are investigated with regard to their dependence on x-ray energy. Sensitometric measurements and a heuristic model for density formation are used to show that variation in the relative amount of light emitted by front and back screens may be the most important factor influencing the change in system H and D curves with x-ray energy

  10. Energy dependence of photon-induced L-shell x-ray intensity ratios in some high-Z elements

    Energy Technology Data Exchange (ETDEWEB)

    Shatendra, K; Allawadhi, K L; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1983-12-14

    The L-shell x-ray intensity ratios in Au, Pb, Th and U at various photon energies have been measured and their energy dependence is studied. A comparison of the experimental values is made with those calculated using the x-ray emission rates and subshell photoelectric cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities and fairly good agreement is observed.

  11. Exposure to power frequency magnetic fields suppresses X-ray-induced apoptosis transiently in Ku80-deficient xrs5 cells

    International Nuclear Information System (INIS)

    Tian, Furong; Nakahara, Takehisa; Yoshida, Masami; Honda, Naoko; Hirose, Hideki; Miyakoshi, Junji

    2002-01-01

    In an attempt to determine whether exposure to extremely low frequency (ELF) electromagnetic fields can affect cells, Ku80-deficient cells (xrs5) and Ku80-proficient cells (CHO-K1) were exposed to ELF electromagnetic fields. Cell survival, and the levels of the apoptosis-related genes p21, p53, phospho-p53 (Ser 15 ), caspase-3 and the anti-apoptosis gene bcl-2 were determined in xrs5 and CHO-K1 cells following exposure to ELF electromagnetic fields and X-rays. It was found that exposure of xrs5 and CHO-K1 cells to 60 Hz ELF electromagnetic fields had no effect on cell survival, cell cycle distribution and protein expression. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields for 5 h after irradiation significantly inhibited G 1 cell cycle arrest induced by X-rays (1 Gy) and resulted in elevated bcl-2 expression. A significant decrease in the induction of p53, phospho-p53, caspase-3 and p21 proteins was observed in xrs5 cells when irradiation by X-rays (8 Gy) was followed by exposure to 5 mT ELF magnetic fields. Exposure of xrs5 cells to the ELF electromagnetic fields for 10 h following irradiation significantly decreased X-ray-induced apoptosis from about 1.7% to 0.7%. However, this effect was not found in CHO-K1 cells within 24 h of irradiation by X-rays alone and by X-rays combined with ELF electromagnetic fields. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields following irradiation can affect cell cycle distribution and transiently suppress apoptosis by decreasing the levels of caspase-3, p21, p53 and phospho-p53 and by increasing bcl-2 expression

  12. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    International Nuclear Information System (INIS)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de; Centro Regional de Ciências Nucleares; Universidade Federal de Pernambuco

    2017-01-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  13. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de, E-mail: aidamgandrade@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Centro Regional de Ciências Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE),Recife (Brazil). Centro de Biociências. Departamento de Genética

    2017-11-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  14. X-ray yields from high-energy heavy ions channeled through a crystal: their crystal thickness and projectile dependences

    International Nuclear Information System (INIS)

    Kondo, C.; Takabayashi, Y.; Muranaka, T.; Masugi, S.; Azuma, T.; Komaki, K.; Hatakeyama, A.; Yamazaki, Y.; Takada, E.; Murakami, T.

    2005-01-01

    X-rays emitted from Ar 17+ , Fe 24+ and Kr 35+ ions of about 400 MeV/u transmitting through a thin Si crystal of about 20 μm thickness have been measured in a planar channeling condition and compared with those in a random incident condition. We have found that the X-ray yield from Ar 17+ ions is larger for the channeling condition than for the random incidence, while those from Fe 24+ and Kr 35+ ions are rather smaller. Such tendencies are explained by considering the projectile dependences of excitation and ionization probabilities together with X-ray emission rates. A crude simulation has qualitatively reproduced these experimental results. When the crystal thickness is small, the X-ray yield is smaller in the channeling condition than in the random incident condition, because excitation is depressed. However, for thicker crystals, the X-ray yield is larger, since the survived population of projectile-bound electrons is larger due to small ionization probabilities under the channeling condition. This inversion occurs at a specific crystal thickness depending on projectile species. Whether the thickness of the used crystal is smaller or larger than the inversion thickness determines enhancement or depression of the X-ray yield in the channeling condition

  15. Effects of embryonic and fetal exposure to x-ray, microwaves, and ultrasound

    International Nuclear Information System (INIS)

    Brent, R.L.

    1986-01-01

    Many professionals are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue, but at present ultrasound not only improves obstetric care but also reduces the necessity of diagnostic x-ray procedures. In the field of ionizing radiation, we have as good a comprehension of the biologic effects and the quantitative maximum risks as of any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, intrauterine growth retardation, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation. Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. In establishing maximum permissible levels for the embryo at low exposures, refer to Tables 4, 5, 6, 8, and 9. It is obvious that the risks of 1-rad or 5-rad acute exposure are far below the spontaneous risks of the developing embryo because 15 per cent of human embryos abort, 2.7 to 3.0 per cent of human embryos have major malformations, 4 per cent have intrauterine growth retardation, and 8 to 10 per cent have early- or late-onset genetic disease. 98 references

  16. Molecular mechanism of X-ray-induced p53-dependent apoptosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Hisako [Tokyo Metropolitan Inst. of Medical Center (Japan)

    1999-03-01

    Radiation-induced cell death has been classified into the interphase- and mitotic-ones, both of which apoptosis involving. This review described the molecular mechanism of the apoptosis, focusing on its p53-dependent process. It is known that there are genes regulating cell death either negatively or positively and the latter is involved in apoptosis. As an important factor in the apoptosis, p53 has become remarkable since it was shown that X-ray-induced apoptosis required RNA and protein syntheses in thymocytes and those cells of p53 gene-depleted mouse were shown to be resistant to gamma-ray-induced apoptosis. Radiation sensitivity of MOLT-4 cells derived from human T cell leukemia, exhibiting the typical X-ray-induced p53-dependent apoptosis, depends on the levels of p53 mRNA and protein. p53 is a gene suppressing tumor and also a transcription factor. Consequently, mutation of p53 conceivably leads to the failure of cell cycle regulation, which allows damaged cells to divide without both repair and exclusion due to loss of the apoptotic mechanism, and finally results in carcinogenesis. The radiation effect occurs in the order of the cell damage, inhibition of p53-Mdm2 binding, accumulation of p53, activation of mdm2 transcription, Mdm2 accumulation, p53-protein degradation and recovery to the steady state level. Here, the cystein protease (caspases) plays an important role as a disposing mechanism for cells scheduled to die. However, many are unknown to be solved in future. (K.H.) 119 refs.

  17. Study on exposures in incidents situations involving X-ray generators of industrial use

    International Nuclear Information System (INIS)

    Rios, Paulo B.; Rios, Denise A. da S.

    2014-01-01

    Case studies of accidents involving radiation sources provides valuable information for the improvement of equipment and procedures to be adopted to prevent their recurrence. Therefore, they are recommended as part of the licensing process of radiative facilities. However, when the equipment has no radiological protection requirements or have no record of accidents, an effective method to appropriate this knowledge necessary to improvements of process and project is the investigation of reported incidents and the proposition limit situations where exposures unlikely and even low intensity can occur. This work reviews incidents in X-ray equipment and thickness meters. Emergency situations are also studied in this type of equipment and in an accelerator of electrons self-shielded for curing of paints and varnishes. The exposure estimates are calculated from data collected in workplaces on the distance and time for each proposed case. Although there is no severe consequences to occupational health, the results can be used to improve the quality of training for operators and maintenance technicians, for proposing of new alarm systems and emergency teams procedures and may serve as a warning in inadvertent and avoidable situations of unnecessary exposures

  18. Implementation of a primary standard for a x-ray exposure

    International Nuclear Information System (INIS)

    peixoto, J.G.P.

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-rays of 100 K V to 250 K V of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation, beam homogeneity, influence of beam size and influences of temperature, humidity and atmospheric pressure. Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  19. The problem of channel dependence in foil-absorption X-ray spectroscopy

    International Nuclear Information System (INIS)

    Rodriguez-Trelles, F.; Caputo, M.C.

    1986-01-01

    We analyze the interdependence among measurements of X-ray spectra in the energy range 4-60 keV by a multi-channel instrument. Two methods of estimating it are described. One gives the error magnification expected in spectrum deconvolution resulting from the covariance matrix of the products of filter transmission times detector sensitivity, evaluated over the whole accessible range of photon energies. The other is an extension of the former evaluating the covariance matrices over consecutive energy bands. This extension allows one to analyze channel dependence for each band, thus improving the prospects of filter and detector selection in the design of an experiment. We present tables showing the expected behaviors of several combinations of filters (homogeneous, heterogeneous, doublets, Ross) and detectors (flat, film, diodes). The advantages of heterogeneous filters are emphasized. (orig.)

  20. Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors.

    Science.gov (United States)

    Stierstorfer, Karl

    2018-01-01

    To find a simple model for the frequency-dependent detective quantum efficiency (DQE) of photon-counting detectors in the low flux limit. Formula for the spatial cross-talk, the noise power spectrum and the DQE of a photon-counting detector working at a given threshold are derived. Parameters are probabilities for types of events like single counts in the central pixel, double counts in the central pixel and a neighboring pixel or single count in a neighboring pixel only. These probabilities can be derived in a simple model by extensive use of Monte Carlo techniques: The Monte Carlo x-ray propagation program MOCASSIM is used to simulate the energy deposition from the x-rays in the detector material. A simple charge cloud model using Gaussian clouds of fixed width is used for the propagation of the electric charge generated by the primary interactions. Both stages are combined in a Monte Carlo simulation randomizing the location of impact which finally produces the required probabilities. The parameters of the charge cloud model are fitted to the spectral response to a polychromatic spectrum measured with our prototype detector. Based on the Monte Carlo model, the DQE of photon-counting detectors as a function of spatial frequency is calculated for various pixel sizes, photon energies, and thresholds. The frequency-dependent DQE of a photon-counting detector in the low flux limit can be described with an equation containing only a small set of probabilities as input. Estimates for the probabilities can be derived from a simple model of the detector physics. © 2017 American Association of Physicists in Medicine.

  1. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  2. Time-dependent Bloch-Maxwell modelling of 1 mJ, 200 fs seeded soft x-ray laser

    International Nuclear Information System (INIS)

    Zeitoun, Ph.; Oliva, E.; Fajardo, M.; Velarde, P.; Ros, D.; Sebban, S.

    2010-01-01

    Complete text of publication follows. Seeding of high harmonic generation in a soft x-ray plasma amplifier has been first proposed and tested by T. Ditmire and collaborators. The experiment demonstrated low amplification (*2), with a very strong background coming from the soft x-ray laser ASE. Later seeding experiments reached very high amplification factors (up to 600) in both gas (Ph. Zeitoun et al.) and solid amplifiers (Wang et at.). Surprisingly, solid amplifiers extracted less energy (90 nJ) than gas amplifier (∼ 1 μJ) with equivalent pump energy. We recently demonstrated that 50-100 μJ is achievable with adequate plasma tailoring. However, this energy is still low as compared to the 10 mJ per pulse demonstrated on the ASE soft x-ray laser running at PALS facility (Czech Republic). In order to model the seeding process of PALS soft x-ray laser, we developed a time-dependent Bloch-Maxwell model that solves coherently the pumping, amplification and saturation processes. We demonstrated that direct seeding, with femtosecond pulse, a soft x-ray plasma amplifier having gain duration of several 100s of picosecond cannot extract the stored energy keeping the output beam energy in the 100 μJ range. We proposed and fully modelled a new seeding scheme that allows to achieve 10 mJ, 200 fs soft x-ray laser.

  3. Low-dose CT of the paranasal sinuses. Minimizing X-ray exposure with spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, Wolfgang [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany); Radiological Institute, Erlangen (Germany); May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany)

    2016-11-15

    Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192 x 0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 x 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI{sub vol} 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. (orig.)

  4. Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study

    International Nuclear Information System (INIS)

    Haeusler, Uwe; Brix, Gunnar; Czarwinski, Renate

    2009-01-01

    The purpose of this study was to analyse the radiation exposure of medical staff from interventional x-ray procedures. Partial-body dose measurements were performed with thermoluminescent dosimeters (TLD) in 39 physicians and nine assistants conducting 73 interventional procedures of nine different types in 14 hospitals in Germany. Fluoroscopy time and the dose-area product (DAP) were recorded too. The median (maximum) equivalent body dose per procedure was 16 (2,500) μSv for an unshielded person; the partial-body dose per procedure was 2.8 (240) μSv to the eye lens, 4.1 (730) μSv to the thyroid, 44 (1,800) μSv to one of the feet and 75 (13,000) μSv to one of the hands. A weak correlation between fluoroscopy time or DAP and the mean TLD dose was observed. Generally, the doses were within an acceptable range from a radiation hygiene point of view. However, relatively high exposures were measured to the hand in some cases and could cause a partial-body dose above the annual dose limit of 500 mSv. Thus, the use of finger dosimeters is strongly recommended. (orig.)

  5. New results regarding gonadal exposure in urologic X-ray diagnostics

    International Nuclear Information System (INIS)

    Barke, R.

    1977-01-01

    In a dosimetric study the radiation exposure of the gonads of 130 patients is determined with condenser ionization chambers in applying intravenous urography according to the valid examination standard of the Society of Medical radiology of the GDR. Shielding the gonads with 2 mm lead equivalent the gonad dose of men is less than 30 mrem, but more than 850 mrem without shielding. The gonad dose of women computationally determined from measurements of the surface dose, is about 1,200 mrem. As the radiation exposure due to each individual radiograph was recorded, the influencing factors (film size, distance of the lower field margin from the gonads) can be determined. For the statistically significant correlation between body weight and gonad dose regression equations are given which, with standard X-ray examinations, make it possible to calculate the gonad dose for the individual case with a high degree of certainty. The analysis of intravenous urographic examinations shows that there is a greater share of female patients because this type of examination is often used as an additional diagnostic procedure in case of gynaecologic diseases. Problems of exact dosimetry at the ovary can hardly be solved

  6. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  7. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  8. Exposure to rays and radiation hazards in connection with diagnostic X-ray procedures in children

    International Nuclear Information System (INIS)

    Protzer, K.

    1988-01-01

    In this study, figures and data about radiation exposures for diagnostic purposes are surveyed that were collected in connection with X-ray procedures in children. The data were sorted according to body regions and techniques required for their examination so as to permit separate analyses of procedures in the urogenital tract (intravenous urogramme, micturition cystourethrography), thorax (angiocardiogramme, thoractic aortogramme, examinations using cardiac catheters), gastrointestinal system (fluoroscopy and contrast-enhanced irrigoscopy), pelvis (survey radiography), skull (computed tomography) as well as in miscellaneous group of further origins. The second part of the report discusses the uncertainties surrounding the assessment of radiation hazards and indicated radiation doses. A formula is represented for the calculation of life-time reductions that can be applied to any type of cancer and embraces a number of factors like life expectancy at age X, the patient's age at the time of radiotherapy, the five-year-survival rate for the condition under investigation and the diseased organ. At the end of the study, some methods are pointed out that may be helpful in limiting radiation exposure. (KST) [de

  9. Study of energy dependence of a extrapolation chamber in low energy X-rays beams

    International Nuclear Information System (INIS)

    Bastos, Fernanda M.; Silva, Teogenes A. da

    2014-01-01

    This work was with the main objective to study the energy dependence of extrapolation chamber in low energy X-rays to determine the value of the uncertainty associated with the variation of the incident radiation energy in the measures in which it is used. For studying the dependence of energy, were conducted comparative ionization current measurements between the extrapolation chamber and two ionization chambers: a chamber mammography, RC6M model, Radcal with energy dependence less than 5% and a 2575 model radioprotection chamber NE Technology; both chambers have very thin windows, allowing its application in low power beams. Measurements were made at four different depths of 1.0 to 4.0 mm extrapolation chamber, 1.0 mm interval, for each reference radiation. The study showed that there is a variable energy dependence on the volume of the extrapolation chamber. In other analysis, it is concluded that the energy dependence of extrapolation chamber becomes smaller when using the slope of the ionization current versus depth for the different radiation reference; this shows that the extrapolation technique, used for the absorbed dose calculation, reduces the uncertainty associated with the influence of the response variation with energy radiation

  10. Fabrication of open-top microchannel plate using deep X-ray exposure mask made with silicon on insulator substrate

    CERN Document Server

    Fujimura, T; Etoh, S I; Hattori, R; Kuroki, Y; Chang, S S

    2003-01-01

    We propose a high-aspect-ratio open-top microchannel plate structure. This type of microchannel plate has many advantages in electrophoresis. The plate was fabricated by deep X-ray lithography using synchrotron radiation (SR) light and the chemical wet etching process. A deep X-ray exposure mask was fabricated with a silicon on insulator (SOI) substrate. The patterned Si microstructure was micromachined into a thin Si membrane and a thick Au X-ray absorber was embedded in it by electroplating. A plastic material, polymethylmethacrylate (PMMA) was used for the plate substrate. For reduction of the exposure time and high-aspect-ratio fast wet development, the fabrication condition was optimized with respect to not the exposure dose but to the PMMA mean molecular weight (M.W.) changing after deep X-ray exposure as measured by gel permeation chromatography (GPC). Decrement of the PMMA M.W. and increment of the wet developer temperature accelerated the etching rate. Under optimized fabrication conditions, a microc...

  11. Disorders of oxidation homeostasis in the blood and organs of rats under the influence of external x-ray exposure

    International Nuclear Information System (INIS)

    Uzlenkova, N.Je.

    2009-01-01

    The study was performed in the blood and organs (lungs and skin) of male rats weighing 160-180 g. Single external x-ray exposure to minimal and medial lethal doses causes stable disorders in oxidation homeostasis resulting in peroxidation state and development of chronic oxidative stress in the organism of the exposed rats.

  12. Determination of energy absorbed during X-ray exposure of the forearm by means of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Hofmann, E.

    1982-01-01

    LiF dose meters were used to determine radiation doses in conventional X-ray diagnostic pictures of the forearm. The paper describes a method for determining integral doses by using these dose meters. It describes in detail how a phantom forearm apt for the purpose is to be made. In the Federal Republic of Germany, malignant growth incidence due to X-ray pictures of the forearm is enhanced by about .01 cases each year. The malignant growth incidence rate caused by X-ray diagnostic measures is low. It is therefore generally justified to neglect limbs in exemplary studies of radiation exposure. All calculations and considerations took into account that all possible radiation protection measures have been duly applied. (orig./DG) [de

  13. Solar X-rays from Axions: Rest-Mass Dependent Signatures

    CERN Document Server

    Zioutas, Konstantin; Semertzidis, Yannis; Papaevangelou, Thomas; Gardikiotis, Antonios; Dafni, Theopisti; Anastassopoulos, Vassilis

    2010-01-01

    The spectral shape of solar X-rays is a power law. The more active the Sun is, the less steep the distribution. This behaviour can be explained by axion regeneration to X-rays occurring ~400km deep into the photosphere. Their down-comptonization reproduces the measured spectral shape, pointing at axions with rest mass m_a~17 meV/c2, without contradicting astrophysical-laboratory limits. Directly measured soft X-ray spectra from the extremely quiet Sun during 2009 (SphinX mission), though hitherto overlooked, fitt the axion scenario.

  14. Exposure of patients and creation of system of quality assurance in conventional x-ray radiology in Lithuania

    International Nuclear Information System (INIS)

    Morkunas, G.; Ziliukas, J.

    1999-01-01

    One of the most important sources of exposure is medical application of ionizing radiation. X-ray examination comprise a significant part of medical exposure. Doses received by patients and quality of diagnostic images are to be optimized. Measurements of these doses were started by the Radiation Protection Centre in 1997. These measurements are performed in randomly selected x-ray departments all around Lithuania during examinations of chest and lumbar spine. Dose and parameters related to exposure and patient are registered. Quality control measurements by PMX-III are being performed on each x-ray machine used for examination. The results show that in many cases the guidance levels are of entrance surface dose for standard patient determined by the Basic Radiation Protection Standard of Lithuania are exceeded. Quality control of x-ray machines performed in 1997-1999 shows that more than 30% of these machines did not comply with the requirements though in many cases shortcomings are minor and easily removed. (au)

  15. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value

    International Nuclear Information System (INIS)

    Kueppers, C.; Sering, M.; Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.

    2012-01-01

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  16. Angular dependence of optical fibre thermoluminescent dosimeters irradiated using kilo- and megavoltage X-rays

    International Nuclear Information System (INIS)

    Moradi, F.; Ung, N.M.; Mahdiraji, G.A.; Khandaker, M.U.; Entezam, A.; See, M.H.; Taib, N.A.; Amin, Y.M.; Bradley, D.A.

    2017-01-01

    Prior investigation of the suitability of optical fibres as thermoluminescent dosimeters for diagnostic and therapeutic radiation beams has not included detailed study of the effect of beam angulation. Present study of such response has made use of optical fibre of cylindrical shape, exposed to 30 kVp photons from an X-ray tube and a 6 MV photon beam from a linear accelerator. The effect of the irradiation medium was also studied, comparing response free-in-air against on-surface and in-depth irradiations through use of solid-water™ phantom. Standard optical fibre (ø =125 µm) shows non-uniform response to beams delivered at different incident angles. Monte Carlo simulation provided support for the experimental results, also obtaining absorbed dose in the fibres. The results of free-in-air condition simulated with mono-energy beam show angle-independent response for photons within the energy range 100–500 keV, while dependency has been observed for beam energies of <100 keV and >500 keV. Experimentally, the angular dependency up to 35% is observed in 30 kVp free-in-air, while in 6 MeV beam, this is reduced to 20%, 10%, and 3% in free-in-air, on phantom surface, and in-depth conditions, respectively. The observations have been justified by considering the range of secondary electrons in the dosimeter and the effect of scattered radiation. - Highlights: • Irradiated free-in-air standard optical fibre dosimeters show significant angular dependence. • The dependency varies for photon energies obtained at kVp and MV potentials. • The irradiation medium influences the angular dependence. • With MeV beam irradiations under CPE conditions the angular dependence decreases to 3%.

  17. Evaluating X-ray absorption of nano-bismuth oxide ointment for decreasing risks associated with X-ray exposure among operating room personnel and radiology experts

    Directory of Open Access Journals (Sweden)

    M. Rashidi

    2015-12-01

      Conclusion: It seems that due to higher atomic number and lower toxicity, Bi2O3 nanoparticles have better efficiency in X-ray absorbtion, comparing to the lead. Cream and ointment of bismuth oxide nanoparticles can be used as X-ray absorbant for different professions such as physicians, dentists, radiology experts, and operating room staff and consequently increase health and safety of these employees.

  18. An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

    International Nuclear Information System (INIS)

    Lin, Yuan; Samei, Ehsan; Ramirez-Giraldo, Juan Carlos; Gauthier, Daniel J.; Stierstorfer, Karl

    2014-01-01

    Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure

  19. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].

    Science.gov (United States)

    Miyajima, Ryuichi; Fujibuchi, Toshioh; Miyachi, Yusuke; Tateishi, Satoshi; Uno, Yoshinori; Amakawa, Kazutoshi; Ohura, Hiroki; Orita, Shinichi

    2018-01-01

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm during abdominal CT. The maximum dose to the crystalline lens was approximately 600 μSv during head CT. We found that the use of volumetric CT scanning and X-ray protective goggles, and face direction toward the gantry reduced the exposure dose, particularly to the crystalline lens, for which lower equivalent dose during CT scan has been recently recommended in the International Commission on Radiological Protection Publication 118.

  20. Relationship between X-ray exposure and malignant transformation in C3H 10T1/2 cells

    International Nuclear Information System (INIS)

    Kennedy, A.R.; Fox, M.; Murphy, G.; Little, J.B.

    1980-01-01

    The appearance of transformed foci after x-irradiation of the C3H 10T1/2 line of murine cells requires extensive proliferation followed by prolonged incubation under conditions of confluence. When the progeny of irradiated cells are resuspended and plated to determine the number of potential transformed foci, the absolute yield is constant over a wide range of dilutions and is similar to that observed in cultures that have not been resuspended. In addition, for cells exposed to a given x-ray dose, the number of transformed foci per dish is independent of the number of irradiated cells. These observations suggest that few, if any, of the transformed clones occur as a direct consequence of the x-ray exposure and challenge the hypothesis that transformed foci are the clonal products of occasional cells that have experienced an x-ray-induced mutational change. Rather, it appears that at least two steps are involved. We suggest that exposure to x-rays results in a change, for example, the induction or expression of some cell function, in many or all of the cells and that this change is transmitted to the progeny of the surviving cells; a consequence of this change is an enhanced probability of the occurrence of a second step, transformation, when these cells are maintained under conditions of confluence

  1. Comparison of cytogenetic effects after occupational exposure to X-rays with those after foetal pelvimetric exposure

    International Nuclear Information System (INIS)

    Kirsch-Volders, M.; Poma, K.; Verschaeve, L.; Hens, L.; Susanne, C.; Elegem, P. van

    1978-01-01

    In utero acute low-level exposure to X-rays (300 to 350 mrads) induces a significant increase of band-loss in G-trypsin banded chromosomes of umbilical lymphocytes. Results, however, have to be confirmed by dose-effect relation studies and analysis with spectro-photometric scanning of deleted chromosomes. The same in utero exposure induces a significant dissociaton of chromosome pair 13 as revealed by centromere-centromere, angle and association tendency analysis of chromosome distribution in comparison with a control group. Occupational chronic low-level exposure to ionizing radiation does not modify significantly the amount of SCE in lymphocytes of peripheral blood. However, an analysis of centromere-centromere distances, angle values and associaton tendencies of the different chromosome combinations clearly shows an association of chromosome pair 12-16 after exposure to ionizing radiation. It is difficult to assess the exact biological importance of the observed chromosome modifications. However, referring to the already described dissociation of human acrocentric chromosomes after in vivo exposure to low levels of phenyl Hg acetate or inorganic Pb, the chromosome distribution seems not to be significantly disturbed by chronic or acute low-level exposure to ionizing radiation. (author)

  2. Measurement of position dependence of spectral distribution in primary X-ray beam of CT system using compton spectroscopy

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Maeda, Koji; Maeda, Koji

    2005-01-01

    Our purpose is to acquire the diagnostic x-ray spectra of the CT system easily under clinical conditions by Compton scatter spectroscopy using a high resolution Schottky CdTe detector recently developed and to estimate the quality and quantity of these spectra compared the relative exposure measured using an ionization chamber with curves measured by the reconstructed spectra. Although the spectral broadening and the fluctuation were slightly shown, the errors of the relative exposure were under 10%. Though the experimental arrangement of this method is so easy and reconstructed algorithm is simple, these results suggested that this method is little influenced by the variation of dose rates or property of the incident x rays. We therefore propose that the Compton scatter spectroscopy with the newly developed Schottky CdTe detector is suitable for measuring the diagnostic x-ray spectra of the CT system under the clinical conditions and useful for quality assurance and quality control of the clinical x-ray CT system. (author)

  3. Time-dependent search for neutrino emission from X-ray binaries with the ANTARES telescope

    Energy Technology Data Exchange (ETDEWEB)

    Albert, A. [GRPHE—Université de Haute Alsace—Institut universitaire de technologie de Colmar, 34 rue du Grillenbreit, BP 50568, Colmar, 68008 France (France); André, M. [Technical University of Catalonia, Laboratory of Applied Bioacoustics, Rambla Exposició, Vilanova i la Geltrú, Barcelona, 08800 Spain (Spain); Anton, G. [Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erwin-Rommel-Str. 1, Erlangen, 91058 Germany (Germany); Ardid, M. [Institut d' Investigació per a la Gestió Integrada de les Zones Costaneres (IGIC), Universitat Politècnica de València, C/ Paranimf 1, Gandia, 46730 Spain (Spain); Aubert, J.-J. [Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, Marseille, 13288 France (France); Avgitas, T.; Baret, B. [APC, Université Paris Diderot, CNRS/IN2P3, CEA/IRFU, Observatoire de Paris, Sorbonne Paris Cité, Paris, 75205 France (France); Barrios-Martí, J., E-mail: antares.spokesperson@in2p3.fr [IFIC—Instituto de Física Corpuscular (CSIC—Universitat de València), c/ Catedrático José Beltrán, 2, Paterna, Valencia, E-46980 Spain (Spain); and others

    2017-04-01

    ANTARES is currently the largest neutrino telescope operating in the Northern Hemisphere, aiming at the detection of high-energy neutrinos from astrophysical sources. Neutrino telescopes constantly monitor at least one complete hemisphere of the sky, and are thus well-suited to detect neutrinos produced in transient astrophysical sources. A time-dependent search has been applied to a list of 33 X-ray binaries undergoing high flaring activities in satellite data (RXTE/ASM, MAXI and Swift/BAT) and during hardness transition states in the 2008–2012 period. The background originating from interactions of charged cosmic rays in the Earth's atmosphere is drastically reduced by requiring a directional and temporal coincidence with astrophysical phenomena. The results of this search are presented together with comparisons between the neutrino flux upper limits and the neutrino flux predictions from astrophysical models. The neutrino flux upper limits resulting from this search limit the jet parameter space for some astrophysical models.

  4. Azimuthal and polar angle dependence of L X-ray differential cross-sections of Yb at 59.54 keV photon energy

    Energy Technology Data Exchange (ETDEWEB)

    Akkuş, T.; Şahin, Y.; Yılmaz, D., E-mail: ddemir@atauni.edu.tr

    2016-01-01

    Highlights: • The azimuthal and polar angle dependence of L X-ray for Yb is investigated. • The azimuthal angle dependence of Ll and Lα X-rays are observed. • The azimuthal anisotropy of Lβ and Lγ X-rays are not observed. • The polar anisotropy of Ll and Lα X-rays are observed. • The polar anisotropy of Lβ and Lγ X-rays are not observed. - Abstract: The azimuthal and polar angle dependence of L X-ray was investigated in the same experimental setup to remove the existing ambiguity about alignments measurements. We measured Ll, Lα, Lβ and Lγ X-ray differential cross sections of Yb for several different azimuthal angles (30°, 20°, 10°, 0°, −10° and −20°) and polar angles (90°, 100°, 110°, 120°, 130° and 140°) at 59.54 keV photon energy by using a Si(Li) detector. The azimuthal angle dependence of Ll and Lα X-rays were observed. The azimuthal anisotropy of Lβ and Lγ X-rays were not observed. On the other hand, differential cross-sections for Lβ and Lγ X-rays were found independent on the polar angle within experimental error, those for Ll and Lα X-rays depended on the polar angles. Azimuthal and polar angles dependence of L X-ray differential cross-sections contrast with the other experimental and theoretical results, which report evidence of the isotropic emission of Ll and Lα X-rays following photoionization.

  5. Dependence of the sacroiliac indices of the X-ray stage of ankylosing spondylitis (Behterev's disease)

    International Nuclear Information System (INIS)

    Mlychkov, Kh.

    1983-01-01

    A total of 241 patients (482 sacroiliac indices) in different X-ray stage of the disease were studied and the data obtained were correlated with the sacroiliac indices in a control group of 104 normal subjects (208 sacroiliac indices). Sacroiliac indices were obtained by quantitative examination of the zones of interest of the sacroiliac joints and the sacrum, 3 hours after intravenous injection of 99 sup(m)Tc-pyrophosphate in indicator activities of 1.85 MBq/kg. The sacroiliac index levels increased with advancing X-ray stage of the disease within the I-III stage span; in the IV-th X-ray stage there was obvious decrease in these values. There appeared to exist statistically significant differences in the sacroiliac index values during all X-ray stages of the disease, as compared to the data obtained in the control group of healthy individuals (P<0.001). The significance level of the differences between neighbouring stages was low. Peak percentage of negative findings was observed in the zero stage (14.3) and in stage IV (11.7). The high percentage of positive findings in zero stage patients (15.7 per cent) is an evidence of the major sensitivity of quantitative scintigraphy in comparison with X-ray method of examination. (author)

  6. TIME-DEPENDENT ELECTRON ACCELERATION IN BLAZAR TRANSIENTS: X-RAY TIME LAGS AND SPECTRAL FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Tiffany R.; Becker, Peter A. [Department of Physics and Astronomy, George Mason University, Fairfax, VA 22030-4444 (United States); Finke, Justin D., E-mail: pbecker@gmu.edu, E-mail: tlewis13@gmu.edu, E-mail: justin.finke@nrl.navy.mil [U.S. Naval Research Laboratory, Code 7653, 4555 Overlook Avenue SW, Washington, DC 20375-5352 (United States)

    2016-06-20

    Electromagnetic radiation from blazar jets often displays strong variability, extending from radio to γ -ray frequencies. In a few cases, this variability has been characterized using Fourier time lags, such as those detected in the X-rays from Mrk 421 using Beppo SAX. The lack of a theoretical framework to interpret the data has motivated us to develop a new model for the formation of the X-ray spectrum and the time lags in blazar jets based on a transport equation including terms describing stochastic Fermi acceleration, synchrotron losses, shock acceleration, adiabatic expansion, and spatial diffusion. We derive the exact solution for the Fourier transform of the electron distribution and use it to compute the Fourier transform of the synchrotron radiation spectrum and the associated X-ray time lags. The same theoretical framework is also used to compute the peak flare X-ray spectrum, assuming that a steady-state electron distribution is achieved during the peak of the flare. The model parameters are constrained by comparing the theoretical predictions with the observational data for Mrk 421. The resulting integrated model yields, for the first time, a complete first-principles physical explanation for both the formation of the observed time lags and the shape of the peak flare X-ray spectrum. It also yields direct estimates of the strength of the shock and the stochastic magnetohydrodynamical wave acceleration components in the Mrk 421 jet.

  7. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  8. Energy dependent features of X-ray signals in a GridPix detector

    Science.gov (United States)

    Krieger, C.; Kaminski, J.; Vafeiadis, T.; Desch, K.

    2018-06-01

    We report on the calibration of an argon/isobutane (97.7%/2.3%)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy resolution of the detector using both the number of pixels hit and the total measured charge as energy measures. For the latter, the energy resolution σE / E is better than 10% (20%) for energies above 2 keV (0.5 keV). Several characteristics of the recorded events are studied.

  9. MODERN PECULIARITIES OF THE MEDICAL EXPOSURE LEVELS FORMING OF THE TATARSTAN REPUBLIC POPULATION DURING X-RAY PROCEDURES IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    S. A. Ryzhkin

    2015-01-01

    Full Text Available The purpose. The purpose of the investigation is an assessment of the peculiarities of forming and registration of the collective doses of patients and the population of the Tatarsatan Republic (RT from medical exposure and the development of measures for optimization of this radiation factor.Materials and methods. The analysis is based on the forms of the Federal statistical observation № 3-DOZ «Data on the exposure doses to patients obtained during medical radiological examination» (form № 3-DOZ and radiation-hygienic passports of RT for the period from 2006 to 2013.The results. Annually in RT there is an increase of the number of performed X-ray procedures, which reached the value of 6279696 (1.64 procedures per resident per year in 2013. During the reporting period (from 2006 to 2013 the structure of the performed X-ray procedures has also changed. It is observed that the percentage of fluorography procedures in the overall structure decreased from 41.3% to 31.3% at the same time the level of absolute value of annually performed fluorography procedures is stable. There is an increase in the absolute number of radiographic procedures performed during the period from 2578754 to 4072810 X-rays per year, that is 1.58 times higher. Absolute and relative values related to X-ray fluoroscopy examinations decreased from 1.1% to 0.7%. In contrast, the absolute number of annually performed X-ray computed tomography examinations (CT has increased over the period by 3.3 times and percentage of CT in overall structure of X-ray procedure is 2.7%. The number of special investigations has increased in 2.1 times, but the relative value remained at average level of 0.4% on general background of the increasing of X-ray activity in the region. This fact influenced the change in the radiation-hygienic indexes of medical radiation exposure of the population of RT. According to №3-DOZ forms and radiation-hygienic passports of the

  10. Reducing exposure of X-ray radiodiagnosis personnel with use of apron

    International Nuclear Information System (INIS)

    Snobr, J.

    1988-01-01

    Experimental results are presented showing dose reduction in X-ray irradiation thanks to protective aprons from lead-containing rubber. The values were used to calculate a reduction in the effective dose equivalent while using the protective apron for isotropic irradiation and for frontal irradiation. A method for optimizing the lead equivalent of the protective apron is suggested. (author). 7 tabs., 6 refs

  11. X-ray exposure hazards for physicians performing ablation procedures and device implantation

    DEFF Research Database (Denmark)

    Marinskis, Germanas; Bongiorni, Maria Grazia; Dagres, Nikolaos

    2013-01-01

    The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing ...

  12. Trends in x-ray photography and patient exposure dose. Questionnaire survey results compared with those in 1973. [questionnaire survey in 1979

    Energy Technology Data Exchange (ETDEWEB)

    Orito, T; Sanada, S; Maekawa, R; Koshida, K; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine

    1980-04-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired.

  13. XMM-Newton view of X-ray overdensities from nearby galaxy clusters : the environmental dependencies

    NARCIS (Netherlands)

    Caglar,; T.; Hudaverdi,; M.,

    2017-01-01

    In this work, we studied ten nearby (z≤0.038) galaxy clusters to understand possible interactions between hot plasma and member galaxies. A multi-band source detection was applied to detect point-like structures within the intra-cluster medium. We examined spectral properties of a total of 391 X-ray

  14. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  15. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  16. Restoring efficiency of hemopoietic cell transplantation in a mouse lethally irradiated by a total exposure to X rays

    International Nuclear Information System (INIS)

    Doria, Gino

    1959-10-01

    This research thesis reports the study of possibility of treatments (or restoration) of a mouse which has been submitted to a lethal dose of X rays. More particularly, the author compared the restoring efficiency of bone marrow and fetal liver injected in a mouse which had been lethally irradiated by a total exposure to X rays. He also studied the functional status of the hemopoietic graft, and the emergence of the secondary disease in mice which had been as well lethally irradiated and then restored by injection of bone marrow and fetal liver. The author then addressed the influence of the induction of immune tolerance of the host with respect to the donor on the survival of a mouse lethally irradiated and restored by homologue bone marrow [fr

  17. Protocol for X-ray dosimetry and exposure arrangements employed in studies of late somatic effects in mammals

    International Nuclear Information System (INIS)

    Zoetelief, J.; Kogel, A.J. van der; Broerse, J.J.; Scarpa, G.; Dixon-Brown, A.

    1985-01-01

    A number of European laboratories studying the late effects of ionizing radiation in animals have established an effective cooperation within the European Late Effects Project Group (EULEP) since 1970. To facilitate the exchange of biological results several techniques, including quality control of the experimental animals, pathology and dosimetry, have to be standardized. The most important aspects of the procedures for X-irradiation and dosimetry of small animals are summarized. These include recommendations on irradiation conditions, dosimetry methods, characteristics of phantoms and factors affecting X-ray dosimetry. X-irradiation procedures employed by the participating institutes are described and the results of five X-ray dosimetry intercomparisons are reported. The introduction of a common dosimetry protocol has resulted in improvements in exposure arrangements and absolute dosimetry. (author)

  18. Development of a head simulator for exposure dose estimation on patients exposed by odontological X-rays

    International Nuclear Information System (INIS)

    Moura Neto, Francisco N.; Batista, Eutropio V.; Santos, Adriano M.

    2009-01-01

    In the obtaining a odontological radiography, the individual is exposed to te radiation and part of that radiation will be absorbed by his organism. The estimative of absorbed dose can be accomplished through calculations where are considered: the distance from the source to the individual, the energy of the emitted X-ray at the moment of the exposure and the bode region exposed; and as that option does not possess great precision, alternative forms are seek for the quantification such doses. This work proposes the construction of a head simulator to be used in the estimative of absorbed dose in patients, during the accomplishment of the odontological radiographic examinations. As a perspective of work, it is intended to use the phantom to help in the absorbed doses for obtainment of parameters in X-ray odontological devices, contributing of image obtainment with more quality and less radiation dose in the patient

  19. The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

    Directory of Open Access Journals (Sweden)

    Mehrdad Gholami

    2015-07-01

    Full Text Available Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation dose. Materials and Methods This cross-sectional study was performed on seven stationary X-ray units in sixhospitals of Lorestan province. The measurements were performed, using a factory-calibrated Barracuda dosimeter (model: SE-43137. Results According to the results, the highest output was obtained in A Hospital (M1 device, ranging from 107×10-3 to 147×10-3 mGy/mAs. The evaluation of tube voltage accuracy showed a deviation from the standard value, which ranged between 0.81% (M1 device and 17.94% (M2 device at A Hospital. The deviation ranges at other hospitals were as follows: 0.30-27.52% in B Hospital (the highest in this study, 8.11-20.34% in C Hospital, 1.68-2.58% in D Hospital, 0.90-2.42% in E Hospital and 0.10-1.63% in F Hospital. The evaluation of exposure time accuracy showed that E, C, D and A (M2 device hospitals complied with the requirements (allowing a deviation of ±5%, whereas A (M1 device, F and B hospitals exceeded the permitted limit. Conclusion The results of this study showed that old X-ray equipments with poor or no maintenance are probably the main sources of reducing radiographic image quality and increasing patient radiation dose.

  20. An oxygen dependent X-ray lesion in Escherichia coli strain B/r detected by penicillin

    International Nuclear Information System (INIS)

    Gillies, N.E.; Obioha, F.I.; Ratnajothi, N.H.

    1979-01-01

    Enhancement of lethal damage to E. coli B/r by penicillin was observed after X-irradiation under aerobic conditions, but not after exposure to X-rays under anoxia or after U.V. (260 nm) irradiation. No enhancement of damage occurred when incubation with penicillin was delayed for 2 hours after aerobic X-irradiation. This enhancing effect was only detected in this strain and not in the filamentous strain E. coli B. It was concluded that an X-ray induced lesion, sensitive to the presence of oxygen at the time of irradiation and probably located in the cell envelope, initiates filamentation in E. coli B/r, which results in lethal damage in this strain. (author)

  1. X-ray exposure dose for the gonadal gland by the examination of computerized tomography and its protection

    International Nuclear Information System (INIS)

    Moriuchi, Iwao; Kaiya, Hisanori; Hirata, Toshifumi; Asada, Shuichi

    1978-01-01

    Computerized tomography (CT) is very useful for neuroradiological examination, and so it may possibly be used for screening tests. But x-ray exposure dose by a examination of CT is considerable, especially for the male gonadal gland. This study showed that the dose from a complete CT examination of 10 - 15 scans for a male gonadal gland was about 1,800 times more than a single plain neuroradiography. But by only a 0.07 mm lead equivalent protecter, the exposure dose resulting from CT for a gonadal gland could be reduced to 0.0 mrad. (auth.)

  2. Study of the argyrophil structures of thymus connective tissue after exposure to X-rays

    International Nuclear Information System (INIS)

    Beletskij, V.K.; Beletskaya, L.V.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Ehpidemiologii i Mikrobiologii)

    1980-01-01

    Studied are argyrophil structures of thymus connective tissue - histiocytes (appendiculate macrophages) and reticuline fibers after the bulk of lymphoid cells has migrated from the organ due to irradiation of animals with X-rays. 10 intact and 16 experimental guinea pigs subjected to the whole-body irradiation with X-rays in the dose of 1000-3000 rad have been used for investigations. It is shown that argyrophil stroma elements of thymus connective tissue, histiocytes and reticular cells, are rather resistant to X-rays and preserve their argyrophily property in the irradiation with high doses, as well as the epithelial cells of the organ. Paraplastic structures in irradiated animals are expressed more completely being demasked as a result of lymphocyte migration and death. The expressed hypertrophy and proliferation of reticular cells and appendiculate macrophages are probably the response to the alternative process in the organ tissues caused by irradiation. A close structural connection of reticular and epithelial tissues on the territory of both layers of thymus sections is noted

  3. Top layer's thickness dependence on total electron-yield X-ray standing-wave

    International Nuclear Information System (INIS)

    Ejima, Takeo; Yamazaki, Atsushi; Banse, Takanori; Hatano, Tadashi

    2005-01-01

    A Mo single-layer film with a stepwise thickness distribution was fabricated on the same Mo/Si reflection multilayer film. Total electron-yield X-ray standing-wave (TEY-XSW) spectra of the aperiodic multilayer were measured with reflection spectra. The peak positions of the standing waves in the TEY-XSW spectra changed as the film thickness of the top Mo-layer increased

  4. Peculiar time dependence of unexpected lines in delayed beam-foil X-ray spectra of V, Fe and Ni

    International Nuclear Information System (INIS)

    Ahmad, Nissar; Karn, Ranjeet K.; Marketos, Pan; Nandi, T.

    2005-01-01

    Delayed beam-foil X-ray spectra of highly charged ions of V, Fe and Ni show a few lines at energies higher than the H-like Lyman α-line of the respective projectile ions. These can only be attributed to heavier ions. Further the time dependence of such unexpected lines display a peculiar behavior. This work presents the experimental observations systematically

  5. Observation of material, thickness, and bremsstrahlung x-ray intensity dependent effects in moderate and high Z targets in a gamma and x-ray LIDAR experiment

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaodong, E-mail: xzhang39@utk.edu [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Ayaz-Maierhafer, Birsen; Laubach, Mitchell A. [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Hayward, Jason P. [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Oak Ridge National Lab, Oak Ridge, TN 37831 (United States)

    2015-06-01

    A high energy gamma and x-ray LIDAR system consisting of a fast pulse (~50 ps, FWHM) LINAC and a Cherenkov detection system was used to investigate response differences among materials, their thicknesses, and bremsstrahlung x-ray intensities. The energies and pulse width of electrons used to produce bremsstrahlung x-rays were set at 20 or 40 MeV and 50 ps FWHM duration, respectively. The Cherenkov detector was built with a fused silica glass optically coupled to a 51 mm fast timing photomultiplier tube, which has an intrinsic energy threshold of 340.7 keV for Compton backscattered gammas. Such a fast detection system yields a coincidence resolving time of 93 ps FWHM, which is equivalent to a depth resolving capability of about 3 cm FWHM. The thicknesses of iron and lead targets were varied from 1 in. to 7 in. with a step of 1 in., and the thicknesses of DU were varied from 1/3 in. to 1 in. with a step of 1/3 in. The experimental results show that iron targets tend to produce a factor of five less observed x-rays and gammas, with less energetic photoelectron frequency distributions, compared with DU and lead targets for the same beam intensity and target thicknesses. Additionally, the self-shielding effect causes the lead to yield more gammas than the DU considering the experimental observation point. For the setup used in this study, a charge per pulse in the range of 1–2.5 nC yields the best resolving capability between the DU and lead targets.

  6. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Science.gov (United States)

    Xu, Ping; Luo, Hong; Huang, Guang-Lei; Yin, Xin-Hai; Luo, Si-Yang; Song, Ju-Kun

    2015-01-01

    Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma. The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR) estimates and 95% confidence intervals (95% CIs) were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed. Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34). However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34). Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed. Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  7. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Directory of Open Access Journals (Sweden)

    Ping Xu

    Full Text Available Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma.The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR estimates and 95% confidence intervals (95% CIs were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed.Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34. However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34. Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed.Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  8. Cell survival studies using ultrasoft x rays

    International Nuclear Information System (INIS)

    Schillaci, M.E.; Raju, M.R.; Carpenter, S.; Cornforth, M.; Wilder, M.

    1987-01-01

    Cell survival was studied for V79 hamster, 10T1/2 mouse, and human skin fibroblast cell lines, using carbon K (0.28 keV), copper K (8.0 keV), and 250 kVp x rays. Because of the rapid attenuation of the carbon x rays, cellular dimensions at the time of exposure were measured using optical and electron microscopy, and frequency distributions of mean dose absorbed by the cell nucleus were obtained. The results indicate that the differences in cell killing between ultra-soft and hard x rays may depend on the nuclear thickness of the cells. Studies of the effects of hypoxia on V79 and 10T1/2 cells using carbon K, aluminum K (1.5 keV), and copper K x rays show decreasing OER values with decreasing x-ray energy and no difference between the two cell lines. Age response studies with V79 cells show similar cell-cycle variation of survival for carbon K and aluminum K x rays as for hard x rays

  9. Development of an algorithm for X-ray exposures using the Panasonic UD-802A thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    McKittrick, Leo; Currivan, Lorraine; Pollard, David; Nicholls, Colyn; Romero, A.M.; Palethorpe, Jeffrey

    2008-01-01

    Full text: As part of its continuous quality improvement the Dosimetry Service of the Radiological Protection Institute of Ireland (RPII) in conjunction with Panasonic Industrial Europe (UK) has investigated further the use of the standard Panasonic algorithm for X-ray exposures using the Panasonic UD-802A TL dosemeter. Originally developed to satisfy the obsolete standard ANSI 13.11-1983, the standard Panasonic dose algorithm has undergone several revisions such as HPS N13.11-2001. This paper presents a dose algorithm that can be used to correct the dose response at low energies such as X-ray radiation using a four element TL dosemeter due to the behaviour of two different independent phosphors. A series of irradiations with a range of energies using N-20 up to Co-60 were carried out with our particular interest being in responses to X-ray irradiations. Irradiations were performed at: RRPPS, University Hospital Birmingham NHS Foundation Trust, U.K.; HPA, U.K. and CIEMAT, Madrid, Spain. Different irradiation conditions were employed which included: X-ray from narrow and wide spectra as described by ISO 4037-1 (1996), and ISO water slab phantom and PMMA slab phantom respectively. Using the UD-802A TLD and UD-854AT hanger combination, the response data from the series of irradiations was utilised to validate and if necessary, modify the photon/beta branches of the algorithm to: 1. Best estimate Hp(10) and Hp(0.07); 2. Provide information on irradiation energies; 3. Verification by performance tests. This work further advances the algorithm developed at CIEMAT whereby a best-fit, polynomial trend is used with the dose response variations between the independent phosphors. (author)

  10. ERX: a software for editing files containing X-ray spectra to be used in exposure computational models

    International Nuclear Information System (INIS)

    Cabral, Manuela O.M.; Vieira, Jose W.; Silva, Alysson G.; Leal Neto, Viriato; Oliveira, Alex C.H.; Lima, Fernando R.A.

    2011-01-01

    Exposure Computational Models (ECMs) are utilities that simulate situations in which occurs irradiation in a given environment. An ECM is composed primarily by an anthropomorphic model (phantom), and a Monte Carlo code (MC). This paper presents a tutorial of the software Espectro de Raios-X (ERX). This software performs reading and numerical and graphical analysis of text files containing diagnostic X-ray spectra for use in algorithms of radioactive sources in the ECMs of a Grupo de Dosimetria Numerica. The ERX allows the user to select one among several X-ray spectrums in the energy range Diagnostic radiology X-Ray most commonly used in radiology clinics. In the current version of the ERX there are two types of input files: the contained in mspectra.dat file and the resulting of MC simulations in Geant4. The software allows the construction of charts of the Probability Density Function (PDF) and Cumulative Distribution Function (CDF) of a selected spectrum as well as the table with the values of these functions and the spectrum. In addition, the ERX allows the user to make comparative analysis between the PDF graphics of the two catalogs of spectra available, besides being can perform dosimetric evaluations with the selected spectrum. A software of this kind is an important computational tool for researchers in numerical dosimetry because of the diversity of Diagnostic radiology X-Ray machines, which implies in a mass of input data highly diverse. And because of this, the ERX provides independence to the group related to the data origin that is contained in the catalogs created, not being necessary to resort to others. (author)

  11. Fast Time-Dependent Density Functional Theory Calculations of the X-ray Absorption Spectroscopy of Large Systems.

    Science.gov (United States)

    Besley, Nicholas A

    2016-10-11

    The computational cost of calculations of K-edge X-ray absorption spectra using time-dependent density functional (TDDFT) within the Tamm-Dancoff approximation is significantly reduced through the introduction of a severe integral screening procedure that includes only integrals that involve the core s basis function of the absorbing atom(s) coupled with a reduced quality numerical quadrature for integrals associated with the exchange and correlation functionals. The memory required for the calculations is reduced through construction of the TDDFT matrix within the absorbing core orbitals excitation space and exploiting further truncation of the virtual orbital space. The resulting method, denoted fTDDFTs, leads to much faster calculations and makes the study of large systems tractable. The capability of the method is demonstrated through calculations of the X-ray absorption spectra at the carbon K-edge of chlorophyll a, C 60 and C 70 .

  12. Inquiry on the radiation exposure of the Swiss population by X-ray diagnosis

    International Nuclear Information System (INIS)

    Poretti, G.G.; Bern Univ.; Jonesco-Farca, F.; Lanz, W.

    1976-01-01

    The genetic load on a population is usually expressed in terms of the so-called 'Genetically Significant Dose' (GSD), i.e. the dose which, averaged over the total population, produces the same results as the varying amounts of radiation received in reality by the individuals making up the population. It may be calculated taking into account the following parameters: 1) total number of male and female persons in the population per age group, including the foetuses, 2) average expectation of children per person, 3) number of persons having received a certain type of X-ray examination, and 4) experimental gonadal dose for this examination (for men, women and foetuses - not to be confused with the GSD). The GSD of the Swiss population for the year 1971 was calculated per age group on the basis of physicians' data on some 60,000 patients. The gonadal dose was determined experimentally in various hospitals by means of TLD dosimeters, sensitive high-pressure ionization chambers and normal chambers. The computer programme to calculate the GSD (PL/1 language) is very time-consuming, but its structure allows a new selective investigation to be made later on by merely changing the input. The results show that in Switzerland as in other countries there is a 3-4% increase per year in X-ray examinations for diagnostic purposes. The GSD for 1971 is 42-43 mrad per person in Switzerland as compared to 22 mrad for 1957. The GSD percentage is about 57% for men, about 35% for women and about 8% for foetuses. The number of X-ray examinations is almost equal for general practitioners (53.8%) and hospitals (46.2%). (orig.) [de

  13. The x-ray source application test cassette for radiation exposures at the OMEGA laser

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B.; Rekow, V.; Emig, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Fisher, J. H.; Newlander, C. D. [Fifth Gait Technologies, Inc., Huntsville, Alabama 35803 (United States); Horton, R. [Gray Research, Inc., Huntsville, Alabama 35806 (United States); Davis, J. [Defense Threat Reduction Agency, Fort Belvoir, Virginia 22060 (United States)

    2012-10-15

    We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

  14. Comparison of x-ray diagnosis associated radiation exposures in Puerto Rico: 1973 vs. 1968

    International Nuclear Information System (INIS)

    Gileadi, M.; Gileadi, A.E.; Musalem, A.

    1975-01-01

    In general, it can be concluded that comparison of 1973 results obtained to date with parallel values for 1968 show a significant improvement in radiation protection practices in Puerto Rico. This improvement, which concerns the whole of society, is not only a result of technical upgrading of the diagnostic equipment, but also and perhaps more significantly, a result of the utmost efforts of professionals: doctors, radiologists and those in radiation protection, to use diagnostic x-rays judiciously, and to reduce the unavoidable doses to a minimum compatible with the diagnostic objective. (U.S.)

  15. Variations in sensitivity of synchronized Chinese hamster cells to oxic and anoxic X-ray exposures

    International Nuclear Information System (INIS)

    Siracka, E.; Littbrand, B.; Clifton, K.H.; Revesz, L.

    1975-01-01

    V-79 Chinese hamster cells in monolayer cultures on glass surfaces were synchronized by treatment with hydroxyurea and then exposed at different times to X-rays in air or in oxygen-free argon. Survival determinations indicated that the oxygen enhancement ratio (OER) as expressed by the ratio of the respective D 0 values varied over a narrow range in the different phases of the cell cycle. These changes resulted from cyclic alterations in both aerobic and anaerobic D 0 values, possibly in n values. (author)

  16. On the radiation exposure dose and health management history during 50 years of x-ray working

    International Nuclear Information System (INIS)

    Yoshida, Tomihiro

    1981-01-01

    My X-ray working history has become 50 years at the end of April, 1980. At this chance, the following data were summarized; the case numbers of X-ray photographs (517,132 cases), total amounts of radiation exposure dose (66.85 roentgen) and the results of blood test, which were experienced during past 50 years. The amounts of exposure dose during 35 years till 1965 were measured using my own method, which measured the film blackening as 30 milli-roentgen per week by certain standard method. After 1966 till 1980, the exposure dose were recorded using that of the film-badge service of Nippon Hoan Yohin Kyokai. The total amounts of exposure dose during 50 years were about 1/4 of D = 5 (N - 18). The results of blood test during last 27 years were found to be normal values. Then, it is happy to say that my body has been protected completely, from radiation hazard as a result of taking radiation protection and checking blood test always at my daily radiation works. The data of my own experiences during 50 years are summarized and reported in this paper. (author)

  17. X-ray detector for a panoramic X-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Cowell, D; Ensslin, F H

    1976-01-15

    The discovery deals with an X-ray detector suitable for the controlling of panoramic X-ray systems. It consists of a fluorescent image screen and a semiconductor photo cell. The output signal of the detector is proportional to the intensity of the X-radiation and the response time is large enough to follow the change of amplitude of the contours of the modulated X radiation. The detector with band-pass filter regulates, via a control system, the moving rate of the X-ray source and of the film opposite it in dependence of the intensity, so that a uniform exposure is ensured.

  18. Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

    Science.gov (United States)

    Kelaranta, Anna; Ekholm, Marja; Toroi, Paula; Kortesniemi, Mika

    2016-01-01

    Dental radiography may involve situations where the patient is known to be pregnant or the pregnancy is noticed after the X-ray procedure. In such cases, the radiation dose to the foetus, though low, needs to be estimated. Uniform and widely used guidance on dental X-ray procedures during pregnancy are presently lacking, the usefulness of lead shields is unclear and practices vary. Upper estimates of radiation doses to the foetus and breasts of the pregnant patient were estimated with an anthropomorphic female phantom in intraoral, panoramic, cephalometric and CBCT dental modalities with and without lead shields. The upper estimates of foetal doses varied from 0.009 to 6.9 μGy, and doses at the breast level varied from 0.602 to 75.4 μGy. With lead shields, the foetal doses varied from 0.005 to 2.1 μGy, and breast doses varied from 0.002 to 10.4 μGy. The foetal dose levels without lead shielding were dental radiographic examination.

  19. Resonant inelastic X-ray spectroscopy of atoms and simple molecules: Satellite features and dependence on energy detuning and photon polarization

    Energy Technology Data Exchange (ETDEWEB)

    Žitnik, M., E-mail: matjaz.zitnik@ijs.si [Jožef Stefan Institute, P.O. Box 3000, SI-1001 Ljubljana (Slovenia); University of Ljubljana, Faculty of Mathematics and Physics, Jadranska 21, SI-1000 Ljubljana (Slovenia); Kavčič, M.; Bohinc, R.; Bučar, K.; Mihelič, A. [Jožef Stefan Institute, P.O. Box 3000, SI-1001 Ljubljana (Slovenia); Cao, W. [Research Centre for Molecular Materials, University of Oulu, P.O. Box 3000, FIN-90014 Oulu (Finland); Guillemin, R.; Journel, L.; Marchenko, T.; Carniato, S.; Kawerk, E. [Sorbonne Universités, UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France); Piancastelli, M.N. [Sorbonne Universités, UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France); Department of Physics and Astronomy, Uppsala University, P.O. Box 516, 75120 Uppsala (Sweden); Simon, M. [Sorbonne Universités, UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France); CNRS, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris (France)

    2015-10-15

    We summarize recent results dealing with high resolution (resonant) X-ray spectroscopy of atomic and molecular targets in the tender X-ray energy region. We comment on advantages, new possibilities and problems related to RIXS spectroscopy with respect to the standard photoabsorption technique, where scanning the probe energy is the only option. In particular, three research areas are covered: X-ray emission mediated by energy dependent photoabsorption to multi-electron excited states, the Cl K core-hole clock studies exemplified by systematic study of chloro(fluoro)-hydrocarbon targets and the polarization dependent X-ray emission studies. Due to its spectral selectivity and simultaneous detection capability, high resolution wavelength dispersive X-ray spectroscopy has the capability to resolve structural and dynamical properties of matter within new instrumentation frontiers.

  20. Resonant inelastic X-ray spectroscopy of atoms and simple molecules: Satellite features and dependence on energy detuning and photon polarization

    International Nuclear Information System (INIS)

    Žitnik, M.; Kavčič, M.; Bohinc, R.; Bučar, K.; Mihelič, A.; Cao, W.; Guillemin, R.; Journel, L.; Marchenko, T.; Carniato, S.; Kawerk, E.; Piancastelli, M.N.; Simon, M.

    2015-01-01

    We summarize recent results dealing with high resolution (resonant) X-ray spectroscopy of atomic and molecular targets in the tender X-ray energy region. We comment on advantages, new possibilities and problems related to RIXS spectroscopy with respect to the standard photoabsorption technique, where scanning the probe energy is the only option. In particular, three research areas are covered: X-ray emission mediated by energy dependent photoabsorption to multi-electron excited states, the Cl K core-hole clock studies exemplified by systematic study of chloro(fluoro)-hydrocarbon targets and the polarization dependent X-ray emission studies. Due to its spectral selectivity and simultaneous detection capability, high resolution wavelength dispersive X-ray spectroscopy has the capability to resolve structural and dynamical properties of matter within new instrumentation frontiers.

  1. X-ray equipment for dental diagnostics with a dose-rate controller influencing the exposure voltage

    International Nuclear Information System (INIS)

    Franke, K.

    1980-01-01

    If a synoptic picture is taken of teeth or jaw the X-ray tube and the film carrier with the film and a radiation detector are moving around the patient's head. The detector signal is connected to the input of the actual value of the dose-rate controller containing a scanning and stop circuit with a storing time roughly corresponding to the exposure of three teeth. After the shot the actual value of the dose rate is adjusted to the desired value, thus a constant quality of the following pictures being achieved. (RW) [de

  2. Application- and patient size-dependent optimization of x-ray spectra for CT

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Deak, Paul; Kellermeier, Markus; Straten, Marcel van; Vollmar, Sabrina V.

    2009-01-01

    Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) for various diagnostic tasks can be minimized. The authors used cylindrical water phantoms and quasianthropomorphic phantoms of the thorax and the abdomen with inserts of 13 mm diameter mimicking soft tissue, bone, and iodine for simulations and measurements. To provide clearly defined contrasts, these inserts were made of solid water with a 1% difference in density (DD) to represent an energy-independent soft-tissue contrast of 10 Hounsfield units (HU), calcium hydroxyapatite (Ca) representing bone, and iodine (I) representing the typical contrast medium. To evaluate CT of the thorax, an adult thorax phantom (300x200 mm 2 ) plus extension rings up to a size of 460x300 mm 2 to mimic different patient cross sections were used. For CT of the abdomen, we used a phantom of 360x200 mm 2 and an extension ring of 460x300 mm 2 . The CT scanner that the authors used was a SOMATOM Definition (Siemens Healthcare, Forchheim, Germany) at 80, 100, 120, and 140 kV. Further voltage settings of 60, 75, 90, and 105 kV were available in an experimental mode. The authors determined contrast for the density difference, calcium, and iodine, and noise and 3D dose distributions for the available voltages by measurements. Additional voltage values and monoenergetic sources were evaluated by simulations. The dose-weighted contrast-to-noise ratio (CNRD) was used as the parameter for optimization. Simulations and measurements were in good agreement with respect to absolute values and trends regarding the dependence on energy for the parameters investigated. For soft-tissue imaging, the standard settings of 120-140 k

  3. The toxicity and anesthetic effect of sodium hydroxybutyrate and ketamine at different periods of the combined radiation injuy , burn trauma and x-ray exposure

    International Nuclear Information System (INIS)

    Il'yuchenok, T.Yu.; Rasulev, B.K.; Moiseeva, L.A.

    1985-01-01

    Mongreal mice have been used to study animal sensitivity under the conditions of combined radiation injury (CRI), separate burn and X-ray effect to sodium hydroxybutyrate and ketamine. It is shown that while administering these anes thetics the differences in the organism reaction depend on the stage of injury and form of exposure. The changes in anesthesia duration in the first days (1-st - 4-th) after radiation exposure are contrary to those at combined radiation-thermal injury and separate burn trauma. The anesthetic effect of ketamine increases under the conditions of combined radiation-thermal injury and is not changed at separate exposures; its toxicity, on the contrary, on the 30-th day after burn and irradiation is increased

  4. The rate of X-ray-induced DNA double-strand break repair in the embryonic mouse brain is unaffected by exposure to 50 Hz magnetic fields.

    Science.gov (United States)

    Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2015-06-01

    Following in utero exposure to low dose radiation (10-200 mGy), we recently observed a linear induction of DNA double-strand breaks (DSB) and activation of apoptosis in the embryonic neuronal stem/progenitor cell compartment. No significant induction of DSB or apoptosis was observed following exposure to magnetic fields (MF). In the present study, we exploited this in vivo system to examine whether exposure to MF before and after exposure to 100 mGy X-rays impacts upon DSB repair rates. 53BP1 foci were quantified following combined exposure to radiation and MF in the embryonic neuronal stem/progenitor cell compartment. Embryos were exposed in utero to 50 Hz MF at 300 μT for 3 h before and up to 9 h after exposure to 100 mGy X-rays. Controls included embryos exposed to MF or X-rays alone plus sham exposures. Exposure to MF before and after 100 mGy X-rays did not impact upon the rate of DSB repair in the embryonic neuronal stem cell compartment compared to repair rates following radiation exposure alone. We conclude that in this sensitive system MF do not exert any significant level of DNA damage and do not impede the repair of X-ray induced damage.

  5. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  6. Tumours associated with medical X-ray therapy exposure in childhood

    International Nuclear Information System (INIS)

    Colman, M.; Kirsch, M.; Creditor, M.

    1978-01-01

    A total of 5166 persons who were exposed to limited field (80-100 cm 2 ) X-ray irradiation to the head, neck and upper chest region during childhood and adolescence have provided an outstanding opportunity for the study of tumour incidence following medical X-ray therapy. More than 3254 subjects have been traced, 3108 have completed questionnaires eliciting information on tumour incidence, and 1539 of these were subjected to a thorough clinical screening procedure that included a thyroid scintigram. The prevalence of thyroid tumours in the 1539 clinically screened subjects and the prevalence of all other tumours in the 3254 subjects traced can therefore be assumed to reflect the risks in the group of irradiated subjects as a whole. Median age at irradiation was 3.5 years, and median radiation dose 790 rads (7.9 Gy). Thyroid tumour was diagnosed in 413 subjects. Of those undergoing surgery (273) 30.3% were found to have thyroid cancer. A total of 366 surgical pathology specimens of the thyroid, including 93 from subjects who were diagnosed at other hospitals, were examined revealing 73 papillary carcinomas, 12 follicular carcinomas and 26 microscopic papillary carcinomas. One hundred and eighty-seven other (non-thyroid) neoplasmas identified included 27 benign and 10 malignant salivary gland tumours, 16 benign and seven malignant tumours of neural origin (brain, spinal cord, cranial and peripheral nerves), 37 skin tumours, 9 lymphomas, 8 gonadal tumours, 45 breast tumours and 28 tumours of miscellaneous sites. The incidence of thyroid tumours, salivary gland tumours and primary brain tumours was considerably in excess of the expected incidence (p values<0.0001), and a radiation dose-effect correlation was observed for thyroid and brain tumours. Gonadal tumours and lymphomas did not occur in excess of the expected incidence

  7. Temperature dependent characterization of gallium arsenide X-ray mesa p-i-n photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Lioliou, G., E-mail: G.Lioliou@sussex.ac.uk; Barnett, A. M. [Semiconductor Materials and Devices Laboratory, Department Engineering and Design, School of Engineering and Informatics, University of Sussex, Falmer, Brighton BN1 9QT (United Kingdom); Meng, X.; Ng, J. S. [Department of Electronic and Electrical Engineering, University of Sheffield, Mappin Street, Sheffield S1 3JD (United Kingdom)

    2016-03-28

    Electrical characterization of two GaAs p{sup +}-i-n{sup +} mesa X-ray photodiodes over the temperature range 0 °C to 120 °C together with characterization of one of the diodes as an X-ray detector over the temperature range 0 °C to 60 °C is reported as part of the development of photon counting X-ray spectroscopic systems for harsh environments. The randomly selected diodes were fully etched and unpassivated. The diodes were 200 μm in diameter and had 7 μm thick i layers. The leakage current density was found to increase from (3 ± 1) nA/cm{sup −2} at 0 °C to (24.36 ± 0.05) μA/cm{sup −2} at 120 °C for D1 and from a current density smaller than the uncertainty (0.2 ± 1.2) nA/cm{sup −2} at 0 °C to (9.39 ± 0.02) μA/cm{sup −2} at 120 °C for D2 at the maximum investigated reverse bias (15 V). The best energy resolution (FWHM at 5.9 keV) was achieved at 5 V reverse bias, at each temperature; 730 eV at 0 °C, 750 eV at 20 °C, 770 eV at 40 °C, and 840 eV at 60 °C. It was found that the parallel white noise was the main source of the photopeak broadening only when the detector operated at 60 °C, at 5 V, 10 V, and 15 V reverse bias and at long shaping times (>5 μs), whereas the sum of the dielectric noise and charge trapping noise was the dominant source of noise for all the other spectra.

  8. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    1998-01-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  9. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo [Fujita Health Univ., Toyoake, Aichi (Japan). School of Health Science; Kamei, Tetsuya; Koga, Sukehiko

    1998-12-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  10. Account of spectral dependence of instrumental factor in quantitative X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Pershin, N.V.; Mosichev, V.I.

    1990-01-01

    A new method for calibration of X-ray fluorescence spectrometers using scanning spectrometric channel is proposed. The method is based on a separate account of matrix and instrumental effects and needs no calibration standards for the element analysed. For calibration in the whole spectral range of XRS (0.03-1.0 nm) it is sufficient to have from 10 to 15 pure element emitters made of most wide spread elements. The method provides rapid development of quantitative analysis for the elements which are not provided with standard samples and preparation of pure element emitters for which is impossible or problematic. The practical verification of the method was made by analysing a set of 146 standard samples covering a wide group of alloys. The mean relative error of the method was 3-5 % in an analytical range of 0.1-3.0 wt %

  11. Observation on Surface Change of Fragile Glass: Temperature - Time Dependence Studied by X-Ray Reflectivity

    International Nuclear Information System (INIS)

    Kikkawa, Hiroyuki; Kitahara, Amane; Takahashi, Isao

    2004-01-01

    The structural change of a fragile glass surface close to the glass transition temperature Tg is studied by using X-ray reflectivity. Measurements were performed on surfaces of maltitol, which is a typical polyalcohol fragile glass with Tg = 320K. Upon both heating and cooling, we find the following features which are also noticed in silicate glass surfaces: (i) On heating, the surface morphology indicates a variation at temperatures below Tg; (ii) A drastic increase in surface roughness occurs at a temperature about 333K on heating, which is 13K higher than Tg; (iii) During the cooling of the sample, formation of a low-density surface layer (3nm at 293K) is observed. Prior to the crystallization, nm - μm sized domains were grown at the surface, which might not be reported for other glasses

  12. Analysis of thin films prepared by vacuum-evaporation and dropping solution by Takeoff Angle-Dependent X-Ray Fluorescence spectroscopy at glancing incidence

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Hirokawa, Kichinosuke; Mitose, Kengo.

    1995-01-01

    We have introduced Takeoff Angle-Dependent X-Ray Fluorescence (TAD-XRF) method for thin film and surface analysis. In this method, the sample on the optically flat substrate is irradiated with the glancing incidence of the primary X-ray, and the fluorescent X-rays emitted from the sample are detected at the glancing takeoff angle. We had previously calculated the relationship between the fluorescent X-ray intensity and the takeoff angle at the glancing incidence. The characterization of the thin film is achieved by investigating the dependence of the fluorescent X-ray intensity on the takeoff angle with the calculated curve. Using this analytical method, we have reported the results of the TAD-XRF measured for the evaporated thin films and the dried films from dropping solution in this paper. The effect of the thickness of the thin film, the density of the substrate and the incident angle on the TAD-XRF curve has been reported. In the case of the dried film from the dropping solution, a broad peak was observed at the takeoff angle which was close to the critical angle for the total reflection of the fluorescent X-ray in the TAD-XRF curve. This broad peak was explained by the double-excitation of the incident beam and the refracted beam of the fluorescent X-ray with the assumption that the X-ray which has a same wavelength to the observed fluorescent X-ray impinges upon the sample surface, because the reciprocity theorem is expected in the X-ray region. (author)

  13. X-ray absorption in insulators with non-Hermitian real-time time-dependent density functional theory.

    Science.gov (United States)

    Fernando, Ranelka G; Balhoff, Mary C; Lopata, Kenneth

    2015-02-10

    Non-Hermitian real-time time-dependent density functional theory was used to compute the Si L-edge X-ray absorption spectrum of α-quartz using an embedded finite cluster model and atom-centered basis sets. Using tuned range-separated functionals and molecular orbital-based imaginary absorbing potentials, the excited states spanning the pre-edge to ∼20 eV above the ionization edge were obtained in good agreement with experimental data. This approach is generalizable to TDDFT studies of core-level spectroscopy and dynamics in a wide range of materials.

  14. Staff and patient exposure to X-ray radiation during cardiac procedures

    International Nuclear Information System (INIS)

    Jankowski, J.; Papierz, D.; Domienik, J.; Kacprzyk, J.; Tybor-Czerwinska, M.; Werduch, A.

    2008-01-01

    The aim of this study was to define and compare staff and patient doses during the most common types of cardiac procedures. The influence of operators' technique and quality of X-ray unit in use on doses received by the staff and patients was investigated. The study was conduced in two independent hemodynamic rooms (I and II). The doses to hand for medical staff (operators and nurses) were monitored. For hand dose assessment, ring thermoluminescent dosimeters were used. Regarding patient dosimetry, dose-area product was collected for selected procedures. The monthly hand doses ranged from 0.4 mSv to 41.2 mSv in room I and from 0.1 to 8.95 mSv in room II. On the basis of the above measurements, the annual doses were estimated. The maximum annual hand doses for the operator and for the nurse in room I were 232.8 mSv/year and 11.5 mSv/year and in room II - 29.8 mSv/year and 14.1 mSv/year, respectively. Additionally, to compare the doses received by the particular medical operators, the doses were normalized to the total workload. Hand dose per procedure ranged from 109 to 614 μSv/procedure and were significantly larger in room I. The typical DAP values (median) recorded for the CA and CA+PTCA procedures were 55 Gy/cm 2 and 171 Gy/cm 2 in room I and 35 Gy/cm 2 and 87 Gy/cm 2 in the room II, respectively. As a result of this survey, the impact of medical operator's experience as well as technique and quality of available X-ray units on doses received by staff and patients has been proven. On the basis of the above results, the special need for monitoring hand doses for medical staff, apart from the effective dose, has been recognized. (author)

  15. Effect of in utero exposure to diagnostic doses of X-rays on the growth and behaviour of mouse

    International Nuclear Information System (INIS)

    Prakash Hande, M.; Uma Devi, P.

    1992-01-01

    Intrauterine development, particularly the period of organogenesis is an especially radiosensitive phase in mammals. Teratogenic effect of low dose irradiation has been demonstrated in laboratory animals. Several studies have indicated the vulnerability of the developing human brain to radiation injury and demonstrated changes in postnatal behaviour following intrauterine animal irradiation. However, data are lacking on the comparative response of the different stages of prenatal development to low doses at levels that could result from diagnostic radiation exposure. This study attempts to empirically evaluate the differential response of critical stages in prenatal development of mouse to single low dose exposures to diagnostic X-rays. Data on growth and behaviour are briefly presented. (author). 22 refs., 2 figs., 1 tab

  16. Measurement of the exposure rate due to low energy x-rays emitted from video display terminals

    International Nuclear Information System (INIS)

    Campos, L.L.

    1988-01-01

    Thermoluminescent dosimeters of CaSO 4 :Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 50 0 . The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h -1 (0.129 μC kg -1 h -1 ) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)

  17. Portable mini-chamber for temperature dependent studies using small angle and wide angle x-ray scattering

    Science.gov (United States)

    Dev, Arun Singh; Kumar, Dileep; Potdar, Satish; Pandit, Pallavi; Roth, Stephan V.; Gupta, Ajay

    2018-04-01

    The present work describes the design and performance of a vacuum compatible portable mini chamber for temperature dependent GISAXS and GIWAXS studies of thin films and multilayer structures. The water cooled body of the chamber allows sample annealing up to 900 K using ultra high vacuum compatible (UHV) pyrolytic boron nitride heater, thus making it possible to study the temperature dependent evolution of structure and morphology of two-dimensional nanostructured materials. Due to its light weight and small size, the chamber is portable and can be accommodated at synchrotron facilities worldwide. A systematic illustration of the versatility of the chamber has been demonstrated at beamline P03, PETRA-III, DESY, Hamburg, Germany. Temperature dependent grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) measurements were performed on oblique angle deposited Co/Ag multilayer structure, which jointly revealed that the surface diffusion in Co columns in Co/Ag multilayer enhances by increasing temperature from RT to ˜573 K. This results in a morphology change from columnar tilted structure to densely packed morphological isotropic multilayer.

  18. Dicentric yields induced in rabbit blood lymphocytes after exposure in vitro to X-rays

    International Nuclear Information System (INIS)

    Inoue, Yoshinori

    1995-06-01

    For the purpose of biological dosimetry, it is essential to establish the relationship between dicentric yields and absorbed doses. The present experiment was carried out to obtain data for rabbit lymphocytes as a reference for this relationship. As data at low dose level are scanty, rabbit lymphocytes were exposed to various doses, especially below 0.5 Gy, of 150 kVp X-rays and analysed at their first mitotic division for dicentric yields. The yields at high dose level were compared with data reported by other authors. The linear-quadratic equation, which is generally accepted, for the dose-response relationship was obtained by the iteratively reweighted least squares method. However, as the present experiment result showed that the dose-response relationship at low dose-levels was likely to be linear, a dose-response line was calculated by the linear regression analysis. As the result of the chi-square tests, it was found that the dicentric yield was better fitted to the linear model at low doses below 0.5 Gy than the linear quadratic model. (author)

  19. Degradation of Albumin on Plasma-Treated Polystyrene by Soft X-ray Exposure

    Directory of Open Access Journals (Sweden)

    Nina Recek

    2016-06-01

    Full Text Available Thin films of human serum albumin (HSA were immobilized on polystyrene (PS substrates previously functionalized either with polar or nonpolar functional groups. The functionalization was performed by treatment with cold gaseous plasma created in pure oxygen and tetrafluoromethane (CF4 plasmas, respectively. Samples were examined with soft X-rays in the photon energy range of 520 to 710 eV in the ANTARES beam line at SOLEIL Synchrotron. NEXAFS spectra of O K-edge and F K-edge were collected at different spots of the sample, and measurements at each spot were repeated many times. A strong degradation of the HSA protein was observed. The weakly irradiated samples exhibited strong absorption at 531.5 eV associated with the O 1s→π*amide transitions, and a broad non distinctive peak at 540 eV was attributed to the O 1s→σ*C–O transitions. Both peaks decreased with increasing irradiation time until they were completely replaced by a broad non-distinctive peak at around 532 eV, indicating the destruction of the original protein conformation. The shortage of the amide groups indicated breakage of the peptide bonds.

  20. Study of the contribution of X-ray and gamma photons to the measured exposure dose

    International Nuclear Information System (INIS)

    Andriampanarivo, H.L.H.

    2000-01-01

    The aim of this work was to study the contribution of X-rays and gamma radiation to the measured dose in the city of Antananarivo. The annual indoor absorbed dose was studied as well. Measurements were carried out in twelve sites, namely public schools and churches. The mean dose rate lies between (0.34±0.03)μSv/h and (0.38±0.04)μSv/h for most of the sites. Two of them showed values between (0.40±0.04)μSv/h and (0.30±0.03)μSv/h. Mean indoor dose rate is of (0.36±0.04)μSv/h and the annual absorbed dose is (3.16±0.32)mSv/person. Indoor measurements showed mean integral values ranging from (277.22±0,22)cps to (733.66±0,37)cps. The lowest mean count rate is (277.22±0,22)cps, measured in the AMARO site, whereas the highest are (733,66±0,37)cps, (697,81±0,36)cps and (689,32±0,36)cps measured in ALO0 , AKELY, and MASINA respectively. [fr

  1. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  2. Normal rejoining of DNA strand breaks in ataxia telangiectasia fibroblast lines after low x-ray exposure

    International Nuclear Information System (INIS)

    Hariharan, P.V.; Eleczko, S.; Smith, B.P.; Paterson, M.C.

    1981-01-01

    The alkaline elution method was used to measure the enzymatic repair of x-ray-induced DNA strand breaks in skin fibroblasts derived from human subjects afflicted with ataxia telangiectasia (AT). Monolayer cultures of normal control and AT cell lines were exposed acutely to moderately lethal (250-rad) and highly lethal (1250-rad) doses of 250-kV x rays under aerobic conditions. Upon receiving 250 rad, the control fibroblasts from a clinically normal donor rejoined all detectable single-strand breaks (plus alkali-labile bonds) within 30 to 60 min of incubation. When challenged with 1250 rad the kinetics of strand rejoining by the normal control cells were biphasic. For both exposures, no significant difference in either the rate or the extent of strand rejoining was detected between the normal cell line (GM38) and three mutant cell lines (AT2BE, AT3BI, AT4BI) belonging to the three known genetic complementation groups in AT. It would thus appear that the enhanced radiosensitivity of cultured AT cells does not stem from faulty rejoining of radiogenic DNA strand breaks

  3. Shield device for controlling the dose of x-rays applied in an x-ray machine

    International Nuclear Information System (INIS)

    Charrier, P.

    1983-01-01

    This invention provides an improved shield for use with an x-ray machine. The shield can control the dose of x-rays applied by the machine in different areas without affecting the power of the x-rays. This is achieved with a shield especially designed and positioned to intercept with x-rays for longer or shorter periods in different areas during the taking of the picture, but not for the whole period of time necessary for taking this picture. Each area of the subject being x-rayed is exposed to full power x-rays. However, owing to the shield, the areas that require smaller dose receive these full power x-rays for a shorter portion of the time required to take the picture while the other areas that require larger dose of x-rays, receive the full power x-rays for a longer portion of the full period of time required to take the picture. To ensure this differential exposure, the shield is placed through the path of the x-rays and rotated about an axis which is generally transverse to the direction of travel of the x-rays to cut out some of said x-rays for different portions of the period of time necessary for taking the picture. The shield is preferably shaped to intercept x-rays for a longer period in some areas than in others depending on the required doses. A plurality of differently shaped shields can be provided to suit different picture taking situations

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Bone X-ray (Radiography)? ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  6. X-ray exposures given with various combinations of film and screen

    International Nuclear Information System (INIS)

    Schlenker, R.A.; Kirsh, I.E.

    A comparison of entrance exposure doses of patients for various film and screen combinations and xeroradiographs showed that moderate speed screen and film gave exposures 4 to 7 times greater than fast film and screen and that xeroradiographs produced exposures 20 to 40 times greater than fast film and screen. Xeroradiographs produced table top incident exposures which exceeded Illinois Department of Health limits, while conventional film-screen combinations did not. (U.S.)

  7. Radiation risk to the patient: a case study involving multiple diagnostic X ray exposures given over a period of 25 years

    International Nuclear Information System (INIS)

    Rainbow, A.J.; McMaster Univ., Hamilton, ON; Roginski, P.; McGeen, W.

    1992-01-01

    The cumulative somatic dose index (SDI) for a number of diagnostic X ray examinations was made for a 60 year old male. The history of diagnostic X ray exposure for this patient from 1957 to 1983 showed 29 diagnostic X ray examinations including more than 100 films and 15 minutes of fluoroscopy. The total cumulative SDI to this patient was 214 mGy (about 21 rad). More than half this dose, 142 mGy, was contributed from upper GI and barium enema examinations which used fluoroscopy, with 88 mGy from the fluoroscopy alone. Using the recently revised risk coefficient for fatal cancer following whole-body irradiation of adult workers recommended by the International Commission on Radiological Protection in 1990, the authors estimate a 0.9% cancer morality risk to this patient resulting from the 29 diagnostic X ray examinations. (author)

  8. Crystallization and preliminary X-ray analysis of the NADPH-dependent 3-quinuclidinone reductase from Rhodotorula rubra

    International Nuclear Information System (INIS)

    Takeshita, Daijiro; Kataoka, Michihiko; Miyakawa, Takuya; Miyazono, Ken-ichi; Uzura, Atsuko; Nagata, Koji; Shimizu, Sakayu; Tanokura, Masaru

    2009-01-01

    The NADPH-dependent 3-quinuclidinone reductase from Rhodotorula rubra was expressed, purified, and crystallized and X-ray diffraction data of this crystal were collected to 2.2 Å resolution. (R)-3-Quinuclidinol is a useful compound that is applicable to the synthesis of various pharmaceuticals. The NADPH-dependent carbonyl reductase 3-quinuclidinone reductase from Rhodotorula rubra catalyzes the stereospecific reduction of 3-quinuclidinone to (R)-3-quinuclidinol and is expected to be utilized in industrial production of this alcohol. 3-Quinuclidinone reductase from R. rubra was expressed in Escherichia coli and purified using Ni-affinity and ion-exchange column chromatography. Crystals of the protein were obtained by the sitting-drop vapour-diffusion method using PEG 8000 as the precipitant. The crystals belonged to space group P4 1 2 1 2, with unit-cell parameters a = b = 91.3, c = 265.4 Å, and diffracted X-rays to 2.2 Å resolution. The asymmetric unit contained four molecules of the protein and the solvent content was 48.4%

  9. Dental X-ray exposure and Alzheimer's disease: a hypothetical etiological association.

    Science.gov (United States)

    Rodgers, Caroline C

    2011-07-01

    Despite the fact that Alzheimer's disease was identified more than 100 years ago, its cause remains elusive. Although the chance of developing Alzheimer's disease increases with age, it is not a natural consequence of aging. This article proposes that dental X-rays can damage microglia telomeres - the structures at the end of chromosomes that determine how many times cells divide before they die - causing them to age prematurely. Degenerated microglia lose their neuroprotective properties, resulting in the formation of neurofibrillary tau tangles and consequently, the neuronal death that causes Alzheimer's dementia. The hypothesis that Alzheimer's is caused specifically by microglia telomere damage would explain the delay of one decade or longer between the presence of Alzheimer's brain pathology and symptoms; telomere damage would not cause any change in microglial function, it would just reset the countdown clock so that senescence and apoptosis occurred earlier than they would have without the environmental insult. Once microglia telomere damage causes premature aging and death, the adjacent neurons are deprived of the physical support, maintenance and nourishment they require to survive. This sequence of events would explain why therapies and vaccines that eliminate amyloid plaques have been unsuccessful in stopping dementia. Regardless of whether clearing plaques is beneficial or harmful - which remains a subject of debate - it does not address the failing microglia population. If microglia telomere damage is causing Alzheimer's disease, self-donated bone marrow or dental pulp stem cell transplants could give rise to new microglia populations that would maintain neuronal health while the original resident microglia population died. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Malformation of the cerebral cortex of rats caused by embryonal exposure to x-ray

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, M [Nagoya Univ. (Japan). Research Inst. of Environmental Medicine

    1978-03-01

    200 R x-ray was irradiated to rat embryos, 17 days of age, and changes of the brain were observed histologically from one hour after the irradiation until they grew up. At start, there was not a great damage in the formation of bundles of major and minor hemisphere commissure passing through the terminal plate, although many cells died or fell off in the new brain mantle. After that, callosal fibers did not reach the midline because of the tissue destruction around the midline, and growth of the stem of the corpus callosum was pressed down. Defect of the stem of the corpus callosum was recognized in adult rats. Surviving mother cells gathered irregularly on the wall of the ventricle at the time of the repair of destructed tissues, and they remained as they stood around the midline of the brain mantle without rearrangement. In adult rats, there was abnormal formation of the cerebral cortex within medullary substances. Marked hypoplasia was recognized in the II-IV layer of the new cortex, bundle branches of dendritic processes of pyramidal cells in the V layer were small in number, and the directions of dendritic processes were abnormal. Pyramidal cell layer of the hippocampus fell into disorder and the directions of dendritic processes were irregular. It was demonstrated by the measurement of cubic volume of each part of the brain using reconstruction method that not only marked hypoplasia of the new cortex and the hippocampus but also hypoplasia of the old cortex, the basal ganglion, and the thalamus in which it was thought to be little disorder in the past were clear.

  11. Malformation of the cerebral cortex of rats caused by embryonal exposure to x-ray

    International Nuclear Information System (INIS)

    Inoue, Minoru

    1978-01-01

    200 R x-ray was irradiated to rat embryos, 17 days of age, and changes of the brain were observed histologically from one hour after the irradiation until they grew up. At start, there was not a great damage in the formation of bundles of major and minor hemisphere commissure passing through the terminal plate, although many cells died or fell off in the new brain mantle. After that, callosal fibers did not reach the midline because of the tissue destruction around the midline, and growth of the stem of the corpus callosum was pressed down. Defect of the stem of the corpus callosum was recognized in adult rats. Surviving mother cells gathered irregularly on the wall of the ventricle at the time of the repair of destructed tissues, and they remained as they stood around the midline of the brain mantle without rearrangement. In adult rats, there was abnormal formation of the cerebral cortex within medullary substances. Marked hypoplasia was recognized in the II-IV layer of the new cortex, bundle branches of dendritic processes of pyramidal cells in the V layer were small in number, and the directions of dendritic processes were abnormal. Pyramidal cell layer of the hippocampus fell into disorder and the directions of dendritic processes were irregular. It was demonstrated by the measurement of cubic volume of each part of the brain using reconstruction method that not only marked hypoplasia of the new cortex and the hippocampus but also hypoplasia of the old cortex, the basal ganglion, and the thalamus in which it was thought to be little disorder in the past were clear. (Iwagami, H.)

  12. A new possibility for production of sub-picosecond x-ray pulses using a time dependent radio frequency orbit deflection

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A.

    2015-10-21

    It is shown that two radio frequency deflecting cavities with slightly different frequencies can be used to produce time-dependent orbit deflection to a few special electron bunches circulating in a synchrotron without affecting the majority of the electron bunches. These special bunches produce an x-ray pulse in which transverse position or angle, or both, are correlated with time. The x-ray pulse is then shortened, either with an asymmetrically cut crystal that acts as a pulse compressor, or with an angular aperture such as a narrow slit positioned downstream. The implementation of this technique creates a highly flexible environment for synchrotrons in which users of most beamlines will be able to easily select between the x-rays originated by the standard electron bunches and the short x-ray pulses originated by the special electron bunches carrying a time-dependent transverse correlation.

  13. A New Possibility for Production of Sub-picosecond X-ray Pulses using a Time Dependent Radio Frequency Orbit Deflection

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A. A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-05-01

    It is shown that two radio frequency deflecting cavities with slightly different frequencies can be used to produce time-dependent orbit deflection to a few special electron bunches while keeping the majority of the electron bunches unaffected. These special bunches produce an x-ray pulse in which transverse position or angle, or both, are correlated with time. The x-ray pulses are then shortened, either with an asymmetrically cut crystal that acts as a pulse compressor, or with an angular aperture such as a narrow slit positioned downstream. The implementation of this technique creates a highly flexible environment for synchrotrons in which users of most beamlines will be able to easily select between the x-rays originated by the standard electron bunches and the short x-ray pulses originated by the special electron bunches carrying a time-dependent transverse correlation.

  14. Intercomparison of the medium energy primary standards for X-ray exposure of NPL and ENEA, Italy

    International Nuclear Information System (INIS)

    Moretti, C.J.; Heaton, J.A.; Laitano, R.F.; Toni, M.P.

    1991-04-01

    An intercomparison between the primary standards of exposure for medium energy X-rays held by the National Physical Laboratory (NPL) and ENEA in Italy is described. The intercomparison, using four different transfer chambers, took place at NPL in December 1989 and at ENEA during March 1990. Measurements were made at four therapy-level qualities, with half value layers of 0.15, 0.5, 1.0 and 2.5 mm Cu (nominal generating voltages of 100, 135, 180 and 250 kV respectively). At the 2.5 mm Cu HVL quality the primary standards were found to agree to within about 0.8%; for the other three qualities the chambers differed by no more than 0.3%. (author)

  15. Age-dependence of the x-ray-induced deficiency in DNA synthesis in HeLa S3 cells during generation 1

    International Nuclear Information System (INIS)

    Griffiths, T.D.; Tolmach, L.J.

    1975-01-01

    The radiation-induced deficiency in DNA synthesis in Generation 1 was studied as a function of the age of HeLa S3 cells at the time of exposure to 220 kV x rays in the previous generation (Generation 0). The amount of DNA synthesized is dependent on the stage in the generation cycle at which cells are irradiated. The smallest deficiency (20 to 35 percent after a dose of 500 rad) is observed in cells irradiated in early G1 or early G2, while the greatest deficiency (55 to 70 percent after 500 rad) is found in cells irradiated at mitosis or at the G1/S transition. The high sensitivity of cells at G1/S is also manifested by a steeper dose-response curve. Cells irradiated in late G2, past the point where their progression is temporarily blocked by x rays, synthesize a normal amount of DNA in Generation 1, while cells that are held up in the G2 block exhibit deficient synthesis in the next generation. The extent of the deficiency in early G1 cells can be enhanced by treatment with 1 mM hydroxyurea for several hours immediately following irradiation. The possibility that deficient DNA synthesis is related to cell killing, and the relation between the G2 block and deficient synthesis, are discussed

  16. Activity-dependent branching ratios in stocks, solar x-ray flux, and the Bak-Tang-Wiesenfeld sandpile model

    Science.gov (United States)

    Martin, Elliot; Shreim, Amer; Paczuski, Maya

    2010-01-01

    We define an activity-dependent branching ratio that allows comparison of different time series Xt . The branching ratio bx is defined as bx=E[ξx/x] . The random variable ξx is the value of the next signal given that the previous one is equal to x , so ξx={Xt+1∣Xt=x} . If bx>1 , the process is on average supercritical when the signal is equal to x , while if bxmarket hypothesis.” For stock volumes, solar x-ray flux intensities, and the Bak-Tang-Wiesenfeld (BTW) sandpile model, bx is supercritical for small values of activity and subcritical for the largest ones, indicating a tendency to return to a typical value. For stock volumes this tendency has an approximate power-law behavior. For solar x-ray flux and the BTW model, there is a broad regime of activity where bx≃1 , which we interpret as an indicator of critical behavior. This is true despite different underlying probability distributions for Xt and for ξx . For the BTW model the distribution of ξx is Gaussian, for x sufficiently larger than 1, and its variance grows linearly with x . Hence, the activity in the BTW model obeys a central limit theorem when sampling over past histories. The broad region of activity where bx is close to one disappears once bulk dissipation is introduced in the BTW model—supporting our hypothesis that it is an indicator of criticality.

  17. Technical study on reduction of patient exposure in x-ray examination

    International Nuclear Information System (INIS)

    Ohtsuka, Akiyoshi

    1983-01-01

    This paper deals with the necessity, problems and technical factors on the reduction of the patient exposure, as well as the source of disagreement between doctors and radiologic technologists with respect to their psychological evaluation of the radiological image quality. (1) The patient exposure has a close relationship to the radiological image quality and is affected by many physical and psychological factors. (2) From the patient's point of view, reduction of the patient exposure without the decrease of the image quality has the same meaning as improving the image quality without the increase of the patient exposure. (3) It is known that, in the observation of the radiological image, the radiologic technologists basically attach more importance to the physical evaluation while doctors attach more importance to the psychological evaluation. (4) If doctors and radiologic technologists have more knowledge concerning the radiological imaging technology, optimization of radiographic technique, reduction of the patient exposure and improvement of the diagnostic accuracy can be expected. (author)

  18. Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method.

    Science.gov (United States)

    Lu, Ping; Moya, Jaime M; Yuan, Renliang; Zuo, Jian Min

    2018-03-01

    The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maxima (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K + L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. With increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping. Published by Elsevier B.V.

  19. A theoretical model predicting the intensity of emitted light per unit of x-ray exposure in radiographic screens

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukos, S; Kateris, A; Kalivas, N; Spyrou, G; Panayiotakis, G [Department of Medical Physics, School of Medicine, University of Patras, 265 00 pAtras (Greece); Kandarakis, I; Gavouras, D [Department of Medical Instrumentation Technology, Technological Educational Institution of Athens (Greece)

    1999-12-31

    A theoretical model predicting the intensity of light emitted by x-ray imaging phosphor screens per unit of area and time over incident x-ray flux (absolute efficiency) was developed. The model takes into account : A) the structure of the screens which consists of luminescent grains embedded in a binding matrix. B) the direct deposition of energy by x-ray absorption effects.. C) the re-absorption of K fluorescence characteristic x-rays produced when the x-ray energy exceeds the energy of the K absorption edge of the phosphor material. To test the model a set of (Gd,La)2O2S:Tb phosphor screens was prepared by sedimentation in the laboratory. Experimental absolute efficiency data were obtained at x-ray tube voltage range from 40 to 160 kVp. The coincidence between experimental and theoretical results were satisfactory. (authors) 7 refs., 4 figs.

  20. X-ray filter for chest X-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    A description is given of an X-ray filter comprised of a sheet of radiation absorbing material with an opening corresponding to the spine and central portion of the heart. The upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter. This filter will permit an acceptable density level of x-ray exposure for the lungs while allowing a higher level of x-ray exposure for the mediastinum areas of the body. (author)

  1. X-ray filter for chest x-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    Filter for use in medical x-ray apparatus to permit higher intensity x-ray exposure in the heart and mediastinum area while maintaining a normal level of x-ray exposure in other areas of the body, particlarly in the lung area. The filter comprises a sheet of radiation absorbing material having an opening therein, said opening corresponding to the spine and central portion of the heart. Accordingly, the upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter

  2. Saffron extracts effect on processes in brain structures under exposure to x-ray irradiation of medium dose

    International Nuclear Information System (INIS)

    Rzaeva, A.

    2012-01-01

    Full text : Process of ionizing radiation on live organism is accompanied by interaction of free radicals (FR) with molecules of proteins, nucleic acids and lipids. In its turn, FR occurs subsequently by excitation and ionization of molecules. Besides all, ionizing radiation becomes the reason of accumulation in body tissues of toxic products (radio toxic) that strengthen beam effect. Endogenous antioxidatic system (EAS) of an organism plays a significant role in detoxication of redundant quantity of FR formed in cells. Ionizing radiation influences negatively to high-grade functioning of basic EAS enzymes. Besides, during radiation injuries, the level of FR increases. In case of its exhaustion and lack insertion of natural antioxidants (bioantioxidants) to organism plays a therapeutic role. Thus, in our work we used saffron extract in experiments with the purpose of studying its effect on the activity of antioxidant enzymes at radiation influence. Determination of proteins has been carried out with Lowry method. In the result of carried-out researches, it has been detected fixed dynamics of activity change of antioxidant enzymes in various brain structures of white rats within x-ray irradiation at medium dose, and joint impact of x-ray radiation of saffron extract. Under exposure to X-ray irradiation of medium dose in some brain structures decreasing of catalase activity was revealed. Tendency towards decreasing is more developed on the 3th day of irradiation. As opposed to catalase activity GPO activity was increased. Insertion of saffron extract to experimental animals (for 21 days before irradiation) conducive to prevention the decreasing of catalase activity stabilizes GPO activity and exerts an effective influence. Thereby, bioantioxidants have significant role in the regulation of processes occurred in tissues and cells under the influence of extreme factors. Antioxidant protection system of organism carries out continuous protection of organism from toxic

  3. DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2013-01-01

    Full Text Available We introduce a system of Diagnostic Reference Levels (DRLs for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different methods of determining the DRLs based on measured and/or calculated quantities of patient’s dose: dose area product (DAP, entrance surface dose (ESD and an effective dose. Distributions of different dose quantities in different Saint-Petersburg clinics are shown on the example of chest PA examinations. The results are compared with the data from other sources. Regional DRLs for Saint-Petersburg are proposed.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  5. Myeloid leukaemia frequency after protracted exposure to ionizing radiation: experimental confirmation of the flat dose-response found in ankylosing spondylitis after a single treatment course with x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Mole, R H; Major, I R [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1983-01-01

    The dose-response for leukaemia induction by exposure to ionizing radiation protracted over several weeks was largely independent of dose not only in X-rayed patients with ankylosing spondylitis but also in experimentally ..gamma..-rayed CBA/H mice. In the experiment the induced leukaemia frequency of acute myeloid leukaemia was independent of a several thousand-fold variation in physical dose rate. Any difference in leukaemia induction between brief and protracted exposures must therefore depend on specifically biological consequences of protracted exposures. Experimental analysis is required to provide the guides for inference about risks of low level exposure from observations on relatively heavily irradiated populations.

  6. Comparison of late effects of single x-ray exposure, chronic tritiated water ingestion, and chronic cesium-137 gamma exposure in mice

    International Nuclear Information System (INIS)

    Carsten, A.L.; Cronkite, E.P.

    1979-01-01

    There is concern over the possible late effects resulting from chronic exposure to tritiated water, a primary by-product of power reactors. We are comparing the genetic and somatic effects of tritiated water ingestion to acute x-ray or chronic cesium-137 gamma-ray exposures. Eight week old mice were maintaned on tritiated water in concentrations of 0.3, 1.0, and 3.0 μCi/ml. Identical animals received cesium-137 gamma exposures equivalent to that from the tritiated water. At 4 week intervals, animals were sacrificed and the hematopoietic stem cell content and cellularity of the bone marrow determined. For comparison of acute and chronic effects, one group of mice received a single whole-body x-ray exposure of 525 rads. The x-irradiated animals showed an immediate sharp decrease in marrow cellularity followed by gradual return to normal levels, with a lifelong reduction in number of marrow stem cells. Animals exposed to the two higher concentrations of tritiated water showed only slight reductions in marrow cellularity, with a lifelong reduction in hematopoietic stem cells in the bone marrow. Comparison of the external gamma exposures to chronic tritiated water ingestion indicates similar patterns. Maintenance of normal cellularity with a reduced number of stem cells in x-rayed animals was shown by tritiated thymidine cytocide to be due to the reduction in number of stem cells in the resting G/sub O/ stage. At this time it is not possible to determine whether there is a significant difference in relative biological effectiveness of tritiated water compared to cesium-137 gamma rays; however, indications are that they are similar

  7. Energy and polarization dependence of resonant inelastic X-ray scattering in Nd2CuO4

    International Nuclear Information System (INIS)

    Hill, J.P.; Kao, C.C.; Haemaelaeinen, K.

    1998-01-01

    The authors report the energy and polarization dependence of resonant inelastic x-ray scattering from Nd 2 CuO 4 . An energy loss feature at ∼6 eV is observed in the vicinity of the Cu K-edge. Numerical calculations based on the Anderson impurity model identify this as a charge transfer excitation to the anti-bonding state. The incident polarization is shown to select the intermediate states participating in the resonance process. Resonances are observed at 8,990 eV and 9,000 eV with the incident polarization perpendicular and parallel to the CuO planes, respectively. In contrast to the single-site model calculations, no resonances are observed associated with the 1s3d 10 L intermediate states, suggesting non-local effects play a role

  8. Crystallization and preliminary X-ray analysis of the NADPH-dependent 3-quinuclidinone reductase from Rhodotorula rubra

    Science.gov (United States)

    Takeshita, Daijiro; Kataoka, Michihiko; Miyakawa, Takuya; Miyazono, Ken-ichi; Uzura, Atsuko; Nagata, Koji; Shimizu, Sakayu; Tanokura, Masaru

    2009-01-01

    (R)-3-Quinuclidinol is a useful compound that is applicable to the synthesis of various pharmaceuticals. The NADPH-dependent carbonyl reductase 3-­quinuclidinone reductase from Rhodotorula rubra catalyzes the stereospecific reduction of 3-quinuclidinone to (R)-3-quinuclidinol and is expected to be utilized in industrial production of this alcohol. 3-Quinuclidinone reductase from R. rubra was expressed in Escherichia coli and purified using Ni-affinity and ion-exchange column chromatography. Crystals of the protein were obtained by the sitting-drop vapour-diffusion method using PEG 8000 as the precipitant. The crystals belonged to space group P41212, with unit-cell parameters a = b = 91.3, c = 265.4 Å, and diffracted X-rays to 2.2 Å resolution. The asymmetric unit contained four molecules of the protein and the solvent content was 48.4%. PMID:19478454

  9. Effect of surface roughness on takeoff-angle-dependent X-ray fluorescence of ultrathin films at glancing incidence

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Hirokawa, Kichinosuke; Sasaki, Atsushi.

    1994-01-01

    We had previously shown that takeoff-angle-dependent X-ray fluorescence (TAD-XRF) at glancing incidence is a useful method for the characterization of thin films. Here we report the effect of surface roughness of the substrate on TAD-XRF of an ultrathin film at a glancing incidence. An optically flat glass, scratched glasses and plano-convex lenses were used as substrates. A large-range contour such as warp and a roughness of microscopic scale affect the TAD-XRF profile. Therefore, to characterize the ultrathin film by the TAD-XRF method, the material whose roughness is being investigated should be used as the substrate in TAD-XRF measurement. (author)

  10. Experimental determination of spin-dependent electron density by joint refinement of X-ray and polarized neutron diffraction data.

    Science.gov (United States)

    Deutsch, Maxime; Claiser, Nicolas; Pillet, Sébastien; Chumakov, Yurii; Becker, Pierre; Gillet, Jean Michel; Gillon, Béatrice; Lecomte, Claude; Souhassou, Mohamed

    2012-11-01

    New crystallographic tools were developed to access a more precise description of the spin-dependent electron density of magnetic crystals. The method combines experimental information coming from high-resolution X-ray diffraction (XRD) and polarized neutron diffraction (PND) in a unified model. A new algorithm that allows for a simultaneous refinement of the charge- and spin-density parameters against XRD and PND data is described. The resulting software MOLLYNX is based on the well known Hansen-Coppens multipolar model, and makes it possible to differentiate the electron spins. This algorithm is validated and demonstrated with a molecular crystal formed by a bimetallic chain, MnCu(pba)(H(2)O)(3)·2H(2)O, for which XRD and PND data are available. The joint refinement provides a more detailed description of the spin density than the refinement from PND data alone.

  11. Teratogenic effects of x-rays

    International Nuclear Information System (INIS)

    Faisal, Arif

    1981-01-01

    The application of x-rays in the medical field has positive and negative effects. The effects of x-ray radiation to the intrauterine embryo and foetus depend on the period of gestation. In the first trimester the embryo may be resorbed and aborted and may also be born with serious defects. In the late trimester radiation may cause less serious defects and it may disturb the function of organs. Many defects involve nerve tissues and are associated with symptoms of mental retardation. To prevent radiation exposure to embryo and foetus, it is necessary to observe the ''ten-day rule'', when x-ray examination is performed. The threshold doses for embryo and foetus are still unknown. (author)

  12. Combinatorial DNA Damage Pairing Model Based on X-Ray-Induced Foci Predicts the Dose and LET Dependence of Cell Death in Human Breast Cells

    Energy Technology Data Exchange (ETDEWEB)

    Vadhavkar, Nikhil [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Pham, Christopher [University of Texas, Houston, TX (United States). MD Anderson Cancer Center; Georgescu, Walter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Deschamps, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Heuskin, Anne-Catherine [Univ. of Namur (Belgium). Namur Research inst. for Life Sciences (NARILIS), Research Center for the Physics of Matter and Radiation (PMR); Tang, Jonathan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.; Costes, Sylvain V. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Div.

    2014-09-01

    In contrast to the classic view of static DNA double-strand breaks (DSBs) being repaired at the site of damage, we hypothesize that DSBs move and merge with each other over large distances (m). As X-ray dose increases, the probability of having DSB clusters increases as does the probability of misrepair and cell death. Experimental work characterizing the X-ray dose dependence of radiation-induced foci (RIF) in nonmalignant human mammary epithelial cells (MCF10A) is used here to validate a DSB clustering model. We then use the principles of the local effect model (LEM) to predict the yield of DSBs at the submicron level. Two mechanisms for DSB clustering, namely random coalescence of DSBs versus active movement of DSBs into repair domains are compared and tested. Simulations that best predicted both RIF dose dependence and cell survival after X-ray irradiation favored the repair domain hypothesis, suggesting the nucleus is divided into an array of regularly spaced repair domains of ~;;1.55 m sides. Applying the same approach to high-linear energy transfer (LET) ion tracks, we are able to predict experimental RIF/m along tracks with an overall relative error of 12percent, for LET ranging between 30 350 keV/m and for three different ions. Finally, cell death was predicted by assuming an exponential dependence on the total number of DSBs and of all possible combinations of paired DSBs within each simulated RIF. Relative biological effectiveness (RBE) predictions for cell survival of MCF10A exposed to high-LET showed an LET dependence that matches previous experimental results for similar cell types. Overall, this work suggests that microdosimetric properties of ion tracks at the submicron level are sufficient to explain both RIF data and survival curves for any LET, similarly to the LEM assumption. Conversely, high-LET death mechanism does not have to infer linear-quadratic dose formalism as done in the LEM. In addition, the size of repair domains derived in our model

  13. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  15. Implication of occupational exposure to X-Rays diagnosed during pregnancy

    International Nuclear Information System (INIS)

    Frometa Suarez, Ileana

    1998-01-01

    At the present time the risks have been described thoroughly and goods on the inherent fetus to the exhibition give sources ionizing radiations in women that are in period gestation. Presently investigation work is carried out for survey of women exposed to occupational ionizing radiations in reproductive age. The incidence is described and behavior gives these goods and its relationship with other risk factors. In this study the exposure to ionizing radiations is not revealed as main causal factor risk

  16. Differential Bystander Signaling Between Radioresistant Chondrosarcoma Cells and Fibroblasts After X-Ray, Proton, Iron Ion and Carbon Ion Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Wakatsuki, Masaru, E-mail: wa@mbe.nifty.com [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Department of Radiation Oncology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts (United States); Magpayo, Nicole; Kawamura, Hidemasa; Held, Kathryn D. [Department of Radiation Oncology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts (United States)

    2012-09-01

    Purpose: Chondrosarcoma is well known as a radioresistant tumor, but the mechanisms underlying that resistance are still unclear. The bystander effect is well documented in the field of radiation biology. We investigated the bystander response induced by X-rays, protons, carbon ions, and iron ions in chondrosarcoma cells using a transwell insert co-culture system that precludes physical contact between targeted and bystander cells. Methods and Materials: Human chondrosarcoma cells were irradiated with 0.1-, 0.5-, 1-, and 2-Gy X-rays, protons, carbon ions or iron ions using a transwell insert co-culture system. Formation of micronuclei and p53 binding protein 1 staining in bystander and irradiated cells were analyzed and bystander signaling between mixed cultures of chondrosarcoma cells, and normal human skin fibroblasts was investigated. Results: In this study, we show that the fraction of cells with DNA damages in irradiated chondrosarcoma cells showed dose-dependent increases with all beams. However, the fraction of cells with DNA damages in all bystander chondrosarcoma cells did not show any change from the levels in control cells. In the bystander signaling between mixed cultures of chondrosarcoma cells and fibroblasts, the amount of micronucleus formation in all bystander chondrosarcoma cells co-cultured with irradiated fibroblasts were the same as the levels for control cells. However, all bystander fibroblasts co-cultured with irradiated chondrosarcoma cells showed significant increases in the fraction of micronucleated cells compared to the rate of control cells. Conclusions: We conclude that chondrosarcoma cells in the transwell insert co-culture system could release bystander stimulations but could not develop bystander responses.

  17. Differential Bystander Signaling Between Radioresistant Chondrosarcoma Cells and Fibroblasts After X-Ray, Proton, Iron Ion and Carbon Ion Exposures

    International Nuclear Information System (INIS)

    Wakatsuki, Masaru; Magpayo, Nicole; Kawamura, Hidemasa; Held, Kathryn D.

    2012-01-01

    Purpose: Chondrosarcoma is well known as a radioresistant tumor, but the mechanisms underlying that resistance are still unclear. The bystander effect is well documented in the field of radiation biology. We investigated the bystander response induced by X-rays, protons, carbon ions, and iron ions in chondrosarcoma cells using a transwell insert co-culture system that precludes physical contact between targeted and bystander cells. Methods and Materials: Human chondrosarcoma cells were irradiated with 0.1-, 0.5-, 1-, and 2-Gy X-rays, protons, carbon ions or iron ions using a transwell insert co-culture system. Formation of micronuclei and p53 binding protein 1 staining in bystander and irradiated cells were analyzed and bystander signaling between mixed cultures of chondrosarcoma cells, and normal human skin fibroblasts was investigated. Results: In this study, we show that the fraction of cells with DNA damages in irradiated chondrosarcoma cells showed dose-dependent increases with all beams. However, the fraction of cells with DNA damages in all bystander chondrosarcoma cells did not show any change from the levels in control cells. In the bystander signaling between mixed cultures of chondrosarcoma cells and fibroblasts, the amount of micronucleus formation in all bystander chondrosarcoma cells co-cultured with irradiated fibroblasts were the same as the levels for control cells. However, all bystander fibroblasts co-cultured with irradiated chondrosarcoma cells showed significant increases in the fraction of micronucleated cells compared to the rate of control cells. Conclusions: We conclude that chondrosarcoma cells in the transwell insert co-culture system could release bystander stimulations but could not develop bystander responses.

  18. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  19. Investigation of Co nanoparticle formation using time-dependent and spatially-resolved X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zinoveva, S.

    2008-04-15

    A crucial step towards controlled synthesis of nanoparticles is the detailed understanding of the various chemical processes that take place during the synthesis. X-ray Absorption Spectroscopy (XAS) is especially suitable for elucidating the type and structure of the intermediate metal species. It is applicable to materials that have no long range order and provides information on both electronic and geometric structures. Here a comparative study is reported of the formation of cobalt nanoparticles via thermolysis of two organometallic precursors dicobalt octacarbonyl (DCO) and alkyne-bridged dicobalt hexacarbonyl (ADH) in the presence of aluminum organics. Using time-dependent XAS a reaction pathway different from both the atom based La Mer model and the Watzky and Finsky autocatalytic surface growth model is observed. Where prior to the nucleation several intermediates are formed and the initial nucleus is composed of Co atoms coordinated with ligands Co{sub n}(CO){sub m} with n=2-3, m=3-5. The formation of Co nanoparticles was also investigated using a reaction different from thermolysis of cobalt carbonyls, namely reduction of Co (II) acetate by sodium borohydrate. Here the combination of microreactor system and spatially resolved XAS allowed ''in situ'' monitoring of the wet chemical synthesis. Several steps of the reaction were spatially resolved in the microreactor. The vertical size of the X-ray beam (50 {mu}m) focused with Kirkpatrick-Baez mirror system, determines the time resolution (better than 2 ms). The results provide direct insight into rapid process of nanoparticles formation and demonstrate the potential of this new technique for the fundamental studies of such type of processes where miniaturization and timeresolution are important. Like in the carbonyls thermolysis no evidence for the reduction of the starting complex to isolated Co{sup 0} atoms followed by nucleation of Co{sup 0} atoms was observed. (orig.)

  20. Investigation of Co nanoparticle formation using time-dependent and spatially-resolved X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zinoveva, S

    2008-04-15

    A crucial step towards controlled synthesis of nanoparticles is the detailed understanding of the various chemical processes that take place during the synthesis. X-ray Absorption Spectroscopy (XAS) is especially suitable for elucidating the type and structure of the intermediate metal species. It is applicable to materials that have no long range order and provides information on both electronic and geometric structures. Here a comparative study is reported of the formation of cobalt nanoparticles via thermolysis of two organometallic precursors dicobalt octacarbonyl (DCO) and alkyne-bridged dicobalt hexacarbonyl (ADH) in the presence of aluminum organics. Using time-dependent XAS a reaction pathway different from both the atom based La Mer model and the Watzky and Finsky autocatalytic surface growth model is observed. Where prior to the nucleation several intermediates are formed and the initial nucleus is composed of Co atoms coordinated with ligands Co{sub n}(CO){sub m} with n=2-3, m=3-5. The formation of Co nanoparticles was also investigated using a reaction different from thermolysis of cobalt carbonyls, namely reduction of Co (II) acetate by sodium borohydrate. Here the combination of microreactor system and spatially resolved XAS allowed ''in situ'' monitoring of the wet chemical synthesis. Several steps of the reaction were spatially resolved in the microreactor. The vertical size of the X-ray beam (50 {mu}m) focused with Kirkpatrick-Baez mirror system, determines the time resolution (better than 2 ms). The results provide direct insight into rapid process of nanoparticles formation and demonstrate the potential of this new technique for the fundamental studies of such type of processes where miniaturization and timeresolution are important. Like in the carbonyls thermolysis no evidence for the reduction of the starting complex to isolated Co{sup 0} atoms followed by nucleation of Co{sup 0} atoms was observed. (orig.)

  1. Activity-dependent branching ratios in stocks, solar x-ray flux, and the Bak-Tang-Wiesenfeld sandpile model.

    Science.gov (United States)

    Martin, Elliot; Shreim, Amer; Paczuski, Maya

    2010-01-01

    We define an activity-dependent branching ratio that allows comparison of different time series X(t). The branching ratio b(x) is defined as b(x)=E[xi(x)/x]. The random variable xi(x) is the value of the next signal given that the previous one is equal to x, so xi(x)=[X(t+1) | X(t)=x]. If b(x)>1, the process is on average supercritical when the signal is equal to x, while if b(x)efficient market hypothesis." For stock volumes, solar x-ray flux intensities, and the Bak-Tang-Wiesenfeld (BTW) sandpile model, b(x) is supercritical for small values of activity and subcritical for the largest ones, indicating a tendency to return to a typical value. For stock volumes this tendency has an approximate power-law behavior. For solar x-ray flux and the BTW model, there is a broad regime of activity where b(x) approximately equal 1, which we interpret as an indicator of critical behavior. This is true despite different underlying probability distributions for X(t) and for xi(x). For the BTW model the distribution of xi(x) is Gaussian, for x sufficiently larger than 1, and its variance grows linearly with x. Hence, the activity in the BTW model obeys a central limit theorem when sampling over past histories. The broad region of activity where b(x) is close to one disappears once bulk dissipation is introduced in the BTW model-supporting our hypothesis that it is an indicator of criticality.

  2. Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

    International Nuclear Information System (INIS)

    Yamada, M.; Komiya, N.; Kawaguchi, A.; Suzuki, M.; Suzuki, Shoichi; Asada, Yasuki

    2008-01-01

    The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE; MS90Tj) system to an FPD (Shimadzu; SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examination of the extent to which exposure could be reduced. Two TV systems were used. We used an analyzer to measure output waveform, tube voltage, and half-value layer (HVL), and an ionization chamber dosimeter to carry out dose-in-air measurements. Body thickness, number of image acquisitions, and fluoroscopy time are required for the calculation of entrance skin dose (ESD). We therefore measured body thicknesses in 1000 upper gastrointestinal tract (UGI) and barium enemas and obtained average body thicknesses for males and females by age group. Values used for number of image acquisitions and fluoroscopy times were the averages in our institution over a two-year period. When an I.I. system was used, the average ESD during UGI examination were 126.8 mGy fluoroscopy dose and 11.62 mGy imaging dose, for an average total dose of 138.42 mGy per examination. ESD during barium enema averaged 201.73 mGy fluoroscopy dose and 45.2 mGy imaging dose, for an average total dose of 246.92 mGy per examination. When an FPD system was used, the average ESD during UGI examination were 58.71 mGy fluoroscopy dose and 5.72 mGy imaging dose, for an average total dose of 64.43 mGy per examination. ESD during barium enema averaged 112.21 mGy fluoroscopy dose and 24.55 mGy imaging dose, for an average total dose of 136.76 mGy per examination. The use of an FPD system reduced both fluoroscopy dose and imaging dose by 50%. The number of TV systems equipped with FPD in Japan has increased from around 1300 in 2006 to around 1700 in 2007. The use of FPD systems can be expected to increase in future. This

  3. Contribution of renal X-ray examinations to the radiation exposure to the population

    International Nuclear Information System (INIS)

    Radtke, I.; Koenig, W.; Menzel, B.

    1978-01-01

    Measured values of the radiation exposure of patients by urography published in the literature are summarized and critically reviewed. The gonad dose to men, women and children has been determined in 6 series of measurements performed according to the recommendations of the Gesellschaft fuer Medizinische Radiologie. Altogether, the determination of the gonad dose based on 927 individual measurements, 230 of them intravaginally, on 226 patients. The surface dose has been determined from 335 measurements. With exact collimation and shielding values of 250 mR for men and 650 mR for women have been obtained as the most probable ones. For 350,000 urographs equally distributed to both sexes and performed under correct working conditions an average per capita dose of 9.2 mR would result. (author)

  4. Contribution of renal X-ray examinations to the radiation exposure to the population

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, I [Staedtisches Klinikum Berlin-Buch (German Democratic Republic). Roentgendiagnostisches Zentrum; Angerstein, W [Forschungsinstitut fuer Tuberkulose und Lungenkrankheiten, Berlin (German Democratic Republic); Koenig, W; Menzel, B [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic)

    1978-04-02

    Measured values of the radiation exposure of patients by urography published in the literature are summarized and critically reviewed. The gonad dose to men, women and children has been determined in 6 series of measurements performed according to the recommendations of the Gesellschaft fuer Medizinische Radiologie. Altogether, the determination of the gonad dose based on 927 individual measurements, 230 of them intravaginally, on 226 patients. The surface dose has been determined from 335 measurements. With exact collimation and shielding values of 250 mR for men and 650 mR for women have been obtained as the most probable ones. For 350,000 urographs equally distributed to both sexes and performed under correct working conditions an average per capita dose of 9.2 mR would result.

  5. Hospital and clinic survey estimates of medical X-ray exposure in Hiroshima and Nagasaki, 2

    International Nuclear Information System (INIS)

    Antoku, Shigetoshi; Hoshi, Masaharu; Sawada, Shozo; Russell, W.J.

    1987-07-01

    The technical factors used during radiological examinations performed in Hiroshima and Nagasaki medical institutions were analyzed. The most frequently performed examination was chest radiography, followed by upper GI series. More than half the radiographic exposures were from upper GI series due to the many spot films made during fluoroscopy. Comparison of the present survey results with those of a previous one showed that relatively high kVp, low mAs and mA, and smaller field sizes are now more widely used. Though there have been decreased in fluoroscopy times and tube currents over the past 10 years, the numbers of spot films used have increased. Based on these technical factors, tables of organ doses from fluoroscopic examinations were compiled. (author)

  6. X-ray diagnostics - benefits and risks

    International Nuclear Information System (INIS)

    Bartholomaeus, Melanie

    2016-01-01

    The brochure on benefits and risks of X-ray diagnostics discusses the following issues: X radiation - a pioneering discovery and medical sensation, fundamentals of X radiation, frequency of X-ray examinations in Germany in relation to CT imaging, radiation doses resulting from X-ray diagnostics, benefits of X-ray diagnostics - indication and examples, risks - measures for radiation exposure reductions, avoidance of unnecessary examinations.

  7. Study of the separate exposure method for bootstrap sensitometry on X-ray cine film

    International Nuclear Information System (INIS)

    Matsuda, Eiji; Sanada, Taizo; Hitomi, Go; Kakuba, Koki; Kangai, Yoshiharu; Ishii, Koushi

    1997-01-01

    We developed a new method for bootstrap sensitometry that obtained the characteristic curve from a wide range, with a smaller number of aluminum steps than the conventional bootstrap method. In this method, the density-density curve was obtained from standard and multiplied exposures to the aluminum step wedge and used for bootstrap manipulation. The curve was acquired from two regions separated and added together, e.g., lower and higher photographic density regions. In this study, we evaluated the usefulness of a new cinefluorography method in comparison with N.D. filter sensitometry. The shape of the characteristic curve and the gradient curve obtained with the new method were highly similar to that obtained with N.D. filter sensitometry. Also, the average gradient obtained with the new bootstrap sensitometry method was not significantly different from that obtained by the N.D. filter method. The study revealed that the reliability of the characteristic curve was improved by increasing the measured value used to calculate the density-density curve. This new method was useful for obtaining a characteristic curve with a sufficient density range, and the results suggested that this new method could be applied to specific systems to which the conventional bootstrap method is not applicable. (author)

  8. Epitope-dependent mechanisms of CD27 neutralization revealed by X-ray crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Obmolova, Galina; Teplyakov, Alexey; Malia, Thomas J.; Wunderler, Nicole; Kwok, Deborah; Barone, Linda; Sweet, Raymond; Ort, Tatiana; Scully, Michael; Gilliland, Gary L. (Janssen)

    2017-03-01

    CD27 is a T and B cell co-stimulatory protein of the TNF receptor superfamily dependent on the availability of the TNF-like ligand CD70. Two anti-CD27 neutralizing monoclonal antibodies were obtained from mouse hybridoma and subsequently humanized and optimized for binding the target. The two antibodies are similar in terms of their CD27-binding affinity and ability to block NF-κB signaling, however their clearance rates in monkeys are very different. The pharmacokinetics profiles could be epitope dependent. To identify the epitopes, we determined the crystal structure of the ternary complex between CD27 and the Fab fragments of these non-competing antibodies. The structure reveals the binding modes of the antibodies suggesting that their mechanisms of action are distinctly different and provides a possible explanation of the in vivo data.

  9. Developable images produced by x-rays using the nickel-hypophosphite system. 2: Exposure and development parameters for sodium hypophosphite

    Science.gov (United States)

    May, C. E.; Philipp, W. H.; Marsik, S. J.

    1972-01-01

    Crystalline sodium hypophosphite was X-irradiated and then treated with an ammoniacal nickel hypophosphite solution. Treatment resulted in the precipitation of nickel metal. The yield of nickel metal varied directly with particle size, sample weight, X-ray voltage, target current, exposure time, and development time. These findings show the process to be potentially useful in X-ray type photography. The half-life for the latent image species was found to be relatively short; but this is not critical in most X-ray photography applications. Furthermore, the work can be interpreted on the basis that a hydrogen atom is involved in the mechanism and indicates that the autocatalytic development step may be self-poisoning.

  10. Women and x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Dunkley, P A; Stewart, J H

    1976-01-01

    When a woman comes to an X-Ray Department it is usually necessary to know the present stage of her menstrual cycle. X-Rays may have an adverse effect on the embryo, especially in early pregnancy. However, exposure to X-Rays at any stage may be associated with a slightly increased incidence of malignant disease in childhood. The International Commission on Radiological Protection recommends that in women of child-bearing age (in some cases as young as 11 years), non-urgent diagnostic radiography be confined to the preovulatory phase of the menstrual cycle: that is, 14 days following the first day of the last menstrual period.

  11. Mutation induction in haploid yeast after split-dose radiation exposure. II. Combination of UV-irradiation and X-rays.

    Science.gov (United States)

    Keller, B; Zölzer, F; Kiefer, J

    2004-01-01

    Split-dose protocols can be used to investigate the kinetics of recovery from radiation damage and to elucidate the mechanisms of cell inactivation and mutation induction. In this study, a haploid strain of the yeast, Saccharomyces cerevisiae, wild-type with regard to radiation sensitivity, was irradiated with 254-nm ultraviolet (UV) light and then exposed to X-rays after incubation for 0-6 hr. The cells were incubated either on nutrient medium or salt agar between the treatments. Loss of reproductive ability and mutation to canavanine resistance were measured. When the X-ray exposure immediately followed UV-irradiation, the X-ray survival curves had the same slope irrespective of the pretreatment, while the X-ray mutation induction curves were changed from linear to linear quadratic with increasing UV fluence. Incubations up to about 3 hr on nutrient medium between the treatments led to synergism with respect to cell inactivation and antagonism with respect to mutation, but after 4-6 hr the two treatments acted independently. Incubation on salt agar did not cause any change in the survival curves, but there was a strong suppression of X-ray-induced mutation with increasing UV fluence. On the basis of these results, we suggest that mutation after combined UV and X-ray exposure is affected not only by the induction and suppression of DNA repair processes, but also by radiation-induced modifications of cell-cycle progression and changes in the expression of the mutant phenotype. Copyright 2004 Wiley-Liss, Inc.

  12. Relaxation processes in aqueous solutions upon X-ray exposure. Entanglement of electronic and nuclear dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Unger, Isaak

    2017-07-01

    About a decade ago new types of electronic non-radiative relaxation processes, involving the environment of an electronically excited or ionized monomer, have been predicted for van der Waals clusters and these were also the first systems where such processes have been detected experimentally. These new autoionization channels encompass the recombination of an electron and a hole, and the energy transfer to a neighboring atom or molecule. Two processes can be distinguished here. In the intermolecular Coulombic decay (ICD) the hole created upon ionization of a monomer is filled by a valence electron of the same species, and the energy released in this electron-hole recombination is used to ionize a neighboring species. In the electron transfer mediated decay (ETMD) the initial hole is filled by an electron from a neighboring species, and the energy released by this recombination is either used to ionize the same neighbor species, or to ionize a third monomer. In more recent experiments on liquid water it has been discovered that these non- local autoionization processes are strongly coupled with ultrafast nuclear dynamics. The core ionization initiates proton motion along a hydrogen donor-bond of the electronically excited water cation. This nuclear dynamics leads to the formation of transient cationic species where a proton is shared by two neighboring water molecules. Subsequent autoionization, either via Auger decay, ICD or ETMD, then occurs from any of such structure transients. This relaxation process is termed proton transfer mediated charge separation, PTM-CS. It has been found in a number of experiments that the probability of PTM-CS to occur depends on the hydrogen-bond strength between the core-ionized molecule and solvent molecules.

  13. Effects of x rays on histogenesis of abnormal epidermis and age dependency of radiosensitivity during metamorphosis of the flesh fly, Sarcophaga peregrina

    International Nuclear Information System (INIS)

    Sasaki, S.; Sakka, M.

    1978-01-01

    Effects of x rays on metamorphosis of the abdominal epidermis in the flesh fly, Sarcophaga peregrina, and age dependence of radiosensitivity were studied. The imaginal epidermis of abdomen is formed from the histoblast nests, which are composed of undifferentiated tiny cells lying between large larval epidermal cells. There were two types of effects of x rays: (1) the arrest of metamorphosis including degeneration of larval epidermal cells and histogenesis of imaginal epidermis; (2) partial deficit of imaginal epidermis at the final stage of development. It was suggested that the second type of effect was brought about by a decrease in the number of abdominal histoblasts caused by x rays. Age dependency of radiosensitivity on the second type of effect was examined in detail, and it was shown that the most sensitive stage occurred just before transition to a highly radiation-resistant period

  14. PRELIMINARY RESULTS IN SYNCHROTRON X-RAY DIFFRACTION MEASUREMENTS OF RUBBER COMPOSITES STRUCTURE BEFORE AND AFTER EXPOSURE TO HYDROGEN

    Directory of Open Access Journals (Sweden)

    Francesca Cosmi

    2011-05-01

    Full Text Available In future years, fuel cells are expected to represent a promising technology as a source of heat and electricity in buildings and of electrical power for vehicles, since fossil fuels are exhausting and significantly degrade air quality. It is well known that, when exposed to a hydrogen environment, hydrogen embrittlerment may affect materials such as iron and steel. But these are not the only materials that are used for hydrogen equipment. In particular, the rubber materials used for O–rings that seal high pressure hydrogen gas equipment show problems of internal fracture, called blister fracture, when the gas is rapidly decompressed. As many different kinds of fillers can be used, in this work we started to investigate the influence of the type of filler on the rubber composites structure, by means of X-ray diffraction measurements performed at the Elettra synchrotron radiation facility in Trieste. In this preliminary study, three kinds of samples were analyzed before and after exposure to hydrogen: Sulphur vulcanized EPDM, Peroxide vulcanized EPDM and Sulphur vulcanized NBR. While Peroxide vulcanized samples did not show significant differences in the diffraction pattern, changes could be detected in the cristalline form of Sulfure vulcanized rubber.

  15. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  16. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Carvalho Júnior, Albérico B.

    2016-01-01

    In this work irradiation scenarios that simulated chest and abdomen examinations involving mobile X-ray equipment in hospitals were modeled with the purpose of calculating conversion coefficient for effective dose (CC E ), normalized to entrance surface dose (ESD), applied to patients and public individuals. These coefficients can easily be used in this practice. Patients and public individuals were represented by a pair of anthropomorphic phantoms inserted in the MCNPX 2.7.0 radiation transport code. One of the phantoms (patient) was irradiated with the direct beam simulating examinations of the chest and abdomen, each with two fields of irradiation, ideal (IF) and extrapolated (EF). Using the software SPECGEN X-ray spectra from 60 to 100 kVp at 10 kVp intervals were generated and used in this work. The other phantom (public individual) was positioned 50–200 cm from the patient. In relation to the CC E calculated in the patient, the average increase obtained between the irradiation fields was 62.4% for the chest examinations, and for the same conditions the CC E was calculated for abdomen examinations and found to be 8.0%. Increasing the distance between public individual and patient, reductions of up to 81.7% in the CC E in abdomen examinations and 83.4% in chest examinations were observed. Through the assessment of CC E of these scenarios, it is possible to measure the damages relating to this practice for both patients and public individuals. - Highlights: • A computational scenario involving mobile X-ray equipment in hospitals were modeled. • Evaluation of medical exposure and exposure by the public was made by CC E (E/ESD). • A pair of the anthropomorphic simulators was inserted into the input file MCNPX. • Analyze the influence in CC E for the different types of fields used in examinations. • Monitoring the reduction of CC E 's with increasing distance between the beds.

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  18. On the Dependence of the X-Ray Burst Rate on Accretion and Spin Rate

    Science.gov (United States)

    Cavecchi, Yuri; Watts, Anna L.; Galloway, Duncan K.

    2017-12-01

    Nuclear burning and its dependence on the mass accretion rate are fundamental ingredients for describing the complicated observational phenomenology of neutron stars (NSs) in binary systems. Motivated by high-quality burst rate data emerging from large statistical studies, we report general calculations relating the bursting rate to the mass accretion rate and NS rotation frequency. In this first work, we ignore general relativistic effects and accretion topology, although we discuss where their inclusion should play a role. The relations we derive are suitable for different burning regimes and provide a direct link between parameters predicted by theory and what is to be expected in observations. We illustrate this for analytical relations of different unstable burning regimes that operate on the surface of an accreting NS. We also use the observed behavior of the burst rate to suggest new constraints on burning parameters. We are able to provide an explanation for the long-standing problem of the observed decrease of the burst rate with increasing mass accretion that follows naturally from these calculations: when the accretion rate crosses a certain threshold, ignition moves away from its initially preferred site, and this can cause a net reduction of the burst rate due to the effects of local conditions that set local differences in both the burst rate and stabilization criteria. We show under which conditions this can happen even if locally the burst rate keeps increasing with accretion.

  19. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  20. Statistical investigation on frequency, duration, number of X-ray investigations and radiation exposure to the patients of a district hospital on the outskirts of Munich

    Energy Technology Data Exchange (ETDEWEB)

    Nordmann, W

    1973-04-10

    Within the framework of a dissertation, X-ray examined patients were statistically surveyed during one month at the district hospital. The radiation exposure of the patients increased strongly particularly with men of the age of 21 to 30 and of 61 to 70. The causes are the multiply performed investigations after accidents as well as angiography at greater ages. The exposure is in the case of women particularly high between the ages of 66 and 70. In determining the gonadal exposure, the average values for the X-ray investigation at the time were referred to. The numbers give an approximate idea of to what extent single investigations with varying investigation or picture frequency can contribute to gonadal exposure.

  1. Estimation of foetus risk from x-ray pelvimetric examinations

    International Nuclear Information System (INIS)

    Iba, Shozo; Sato, Kazuichi

    1983-01-01

    X-ray pelvimetric examinations are carried out for the purpose of diagnosing the cephalo pelvic disproportion at terminal pregnancy and they are still an excellent method, being performed more often than other examinations. However the invitable fetal exposure is considered to be a significant dose and makes an estimation of stochastic fetal risk related to x-ray exposure and to investigate the methods of dose reduction. As the methods judging the exposure dose actually made in the hospitals, a questionnarie regarding the main technical factors of an x-ray examination was given to 26 hospitals, including 5 university hospitals, in Kantou district, and the answeres were analyzed. The estimated risks involving genetics, leukemia and malignant diseases were dependent on the exposure dose which could be calculated on the basis of the technical factors obtained. Total risks on the foetus ranged widely from 1.27 x 10 rad -1 to 1.19 x 10 rad -1 . So for as we have investigated, if all the hospitals used a grid ratio of 5:1, a tube voltage of 120 kV, intensitying screens with rare earth phosphors and green-sensitive orthomatic medical x-ray films for the x-ray pelvimetric examinations, it would be possible to reduce the present exposure dose by one-fourth. The ratio of the x-ray pelvimetry taken on pregnant patients ranged from 2 % to 33 %, having a mean value of 15 %. (author)

  2. Determination of lateral diffusivity in single pixel X-ray absorbers with implications for position dependent excess broadening

    International Nuclear Information System (INIS)

    Saab, T.; Figueroa-Feliciano, E.; Iyomoto, N.; Herbert, B.D.; Bandler, S.R.; Chervenak, J.; Finkbeiner, F.; Kelley, R.L.; Kilbourne, C.A.; Porter, F.S.; Sadleir, J.

    2006-01-01

    An ideal microcalorimeter is characterized by a constant energy resolution across the sensor's dynamic range. Any dependence of pulse shape on the position within the absorber where an event occurs leads to a degradation in resolution that is linear with event's energy (excess broadening). In this paper we present a numerical simulation that was developed to model the variation in pulse shape with position based on the thermal conductivity within the absorber and between the absorber, sensor, and heat bath, for arbitrarily shaped absorbers and sensors. All the parameters required for the simulation can be measured from actual devices. We describe how the thermal conductivity of the absorber material is determined by comparing the results of this model with data taken from a position sensitive detector in which any position dependent effect is purposely emphasized by constructing a long, narrow absorber that is readout by sensors on both ends. Finally, we present the implications for excess broadening given the measured parameters of our X-ray microcalorimeters

  3. Crystallization, optimization and preliminary X-ray characterization of a metal-dependent PI-PLC from Streptomyces antibioticus

    International Nuclear Information System (INIS)

    Jackson, Michael R.; Selby, Thomas L.

    2012-01-01

    Crystallization and diffraction analysis of a Ca 2+ -dependent PI-PLC from Streptomyces is reported. Optimization of crystals was completed using a drop-pinning technique and heavy-atom soaks to achieve high-quality diffraction to 1.23 Å. A recombinant metal-dependent phosphatidylinositol-specific phospholipase C (PI-PLC) from Streptomyces antibioticus has been crystallized by the hanging-drop method with and without heavy metals. The native crystals belonged to the orthorhombic space group P222, with unit-cell parameters a = 41.26, b = 51.86, c = 154.78 Å. The X-ray diffraction results showed significant differences in the crystal quality of samples soaked with heavy atoms. Additionally, drop pinning, which increases the surface area of the drops, was also used to improve crystal growth and quality. The combination of heavy-metal soaks and drop pinning was found to be critical for producing high-quality crystals that diffracted to 1.23 Å resolution

  4. A Concept for z-Dependent Microbunching Measurements with Coherent X-ray Transition Radiation in a SASE FEL

    CERN Document Server

    Lumpkin, Alex H

    2004-01-01

    Previously, measurements in the visible to VUV regimes of z-dependent microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL) have provided important information about the fundamental mechanisms. In those experiments a thin metal foil was used to block the more intense SASE radiation and to generate coherent optical transition radiation (COTR) as one source in a two-foil interferometer. However, for the proposed Linac Coherent Light Source (LCLS), the intense SASE emission is either too strongly transmitted at 1.5 angstroms or the needed foil thickness for blocking scatters the electron beam too much. Since coherent x-ray transition radiation (CXTR) is emitted in an annulus with opening angle 1/γ = 36 µrad for 14.09-GeV electrons, one could use a thin foil or foil stack to generate the XTR and CXTR and an annular crystal to wavelength sort the radiation. The combined selectivity will favor the CXTR over SASE by about eight orders of magnitude. Time-dependent GINGER si...

  5. Stress-dependent crystal structure of lanthanum strontium cobalt ferrite by in situ synchrotron X-ray diffraction

    Science.gov (United States)

    Geiger, Philipp T.; Khansur, Neamul H.; Riess, Kevin; Martin, Alexander; Hinterstein, Manuel; Webber, Kyle G.

    2018-02-01

    Lanthanum strontium cobalt ferrite La1-xSrxCo1-yFeyO3-δ (LSCF) is one of the most studied mixed ionic-electronic conductor materials due to electrical and transport properties, which are attractive for intermediate temperature solid oxide fuel cells (SOFCs), oxygen permeation membranes, and catalysis. The integration of such materials, however, depends on the thermal as well as mechanical behavior. LSCF exhibits nonlinear hysteresis during compressive stress-strain measurements, marked by a remanent strain and coercive stress, i.e., ferroelasticity. However, the origin of ferroelastic behavior has not been investigated under high compressive stress. This study, therefore, investigates the microscopic origin of stress-induced mechanical behavior in polycrystalline (La0.6Sr0.4)0.95Co0.2Fe0.8O3-δ using in situ synchrotron x-ray diffraction. The data presented here reveals that the strain response originates from the intrinsic lattice strain as well as the extrinsic domain switching strain without any apparent change in crystallographic symmetry. A comparison of the calculated microscopic strain contribution with that of a macroscopic measurement indicates a significant change in the relative contributions of intrinsic and extrinsic strain depending on the applied stress state, i.e., under maximum stress and after unloading. Direct evidence of the microscopic origin of stress-strain response outlined in this paper may assist in guiding materials design with the improved mechanical reliability of SOFCs.

  6. Aberrant cell divisions in root meristeme of maize following exposure to X-rays low doses compared to similar effects of 50 Hz electromagnetic exposure

    Directory of Open Access Journals (Sweden)

    Luchian T.

    2012-04-01

    Full Text Available The response of maize to radiation exposure was investigated by two cytogenetic methods considering the importance of the geno-toxic effect for environmental and agricultural purposes. Uniform genophond seeds, freshly germinated, were exposed to relatively low radiation doses using a radiotherapy X-ray applicator from a hospital irradiation device and to a 50 Hz electromagnetic field with about 10 mT magnetic induction (generated within laboratory assembled electromagnetic coils. Radicular meristeme tissue aliquots were prevailed for cytogenetic investigation based on microscopic observations and cell counting. Microscope slides were prepared following a specific procedure (squash technique and Feulgen method based on modified Carr reactive coloration. Mitotic index as well as chromosomal aberration percentage were calculated for more than 30,000 cells taken into account. From a qualitative viewpoint, chromosomal aberrations such as interchromatidian bridges, lagging and expelled chromosomes and multipolar divisions were evidenced - no distinct situation for either ionizing radiation or electromagnetic field being identified. The main quantitative difference consisted in the increased mitotic index for electromagnetic exposure increased times compared with the diminished mitotic index in the case of low X-ray doses.

  7. Dose-response relationship of γ-H2AX foci induction in human lymphocytes after X-rays exposure

    International Nuclear Information System (INIS)

    Mandina, Tania; Roch-Lefevre, Sandrine H.; Voisin, Pascale; Gonzalez, Jorge E.; Lamadrid, Ana I.; Romero, Ivonne; Garcia, Omar; Voisin, Philippe; Roy, Laurence

    2011-01-01

    Biological dosimeters are recommended for dose estimation in case of human overexposure to ionising radiation. Rapid measurement of γ-H2AX foci as a marker of DNA double-strand breaks (DSB) induction has been recently tested with this purpose. Here we reported a dose-response relationship after X-ray irradiation at different times post-exposure. Blood samples were obtained from several healthy donors and exposed to doses between 0 and 2 Gy. After irradiation, blood samples were incubated at 37 deg. C during 0.5 h, 5 h, and 8 h. Scoring of cells and γ-H2AX foci was performed by software. The dose-response curves for different incubation times were as follows: Y (0.5h) = 11.66D + 0.15 (R 2 = 0.99), Y (5h) = 2.44D + 0.15 (R 2 = 0.99), Y (8h) = 1.57D + 0.22 (R 2 = 0.99). At 0.5 h post-exposure, the dose-response relationship for X-irradiated lymphocytes was similar to the one obtained after gamma-irradiation using the same protocol. On the other hand, the results were not similar after 8 h due to different kinetics after gamma- and X-irradiation. Our results confirm the possibilities of using γ-H2AX foci method for dose estimation in a period from 0.5 h up to 8 h post X-irradiation and support the hypothesis of differences in γ-H2AX foci kinetics after gamma- and X-irradiation in vitro.

  8. Radiation-induced signaling results in mitochondrial impairment in mouse heart at 4 weeks after exposure to X-rays.

    Science.gov (United States)

    Barjaktarovic, Zarko; Schmaltz, Dominik; Shyla, Alena; Azimzadeh, Omid; Schulz, Sabine; Haagen, Julia; Dörr, Wolfgang; Sarioglu, Hakan; Schäfer, Alexander; Atkinson, Michael J; Zischka, Hans; Tapio, Soile

    2011-01-01

    Radiation therapy treatment of breast cancer, Hodgkin's disease or childhood cancers expose the heart to high local radiation doses, causing an increased risk of cardiovascular disease in the survivors decades after the treatment. The mechanisms that underlie the radiation damage remain poorly understood so far. Previous data show that impairment of mitochondrial oxidative metabolism is directly linked to the development of cardiovascular disease. In this study, the radiation-induced in vivo effects on cardiac mitochondrial proteome and function were investigated. C57BL/6N mice were exposed to local irradiation of the heart with doses of 0.2 Gy or 2 Gy (X-ray, 200 kV) at the age of eight weeks, the control mice were sham-irradiated. After four weeks the cardiac mitochondria were isolated and tested for proteomic and functional alterations. Two complementary proteomics approaches using both peptide and protein quantification strategies showed radiation-induced deregulation of 25 proteins in total. Three main biological categories were affected: the oxidative phophorylation, the pyruvate metabolism, and the cytoskeletal structure. The mitochondria exposed to high-dose irradiation showed functional impairment reflected as partial deactivation of Complex I (32%) and Complex III (11%), decreased succinate-driven respiratory capacity (13%), increased level of reactive oxygen species and enhanced oxidation of mitochondrial proteins. The changes in the pyruvate metabolism and structural proteins were seen with both low and high radiation doses. This is the first study showing the biological alterations in the murine heart mitochondria several weeks after the exposure to low- and high-dose of ionizing radiation. Our results show that doses, equivalent to a single dose in radiotherapy, cause long-lasting changes in mitochondrial oxidative metabolism and mitochondria-associated cytoskeleton. This prompts us to propose that these first pathological changes lead to an increased

  9. Dose-response relationship of {gamma}-H2AX foci induction in human lymphocytes after X-rays exposure

    Energy Technology Data Exchange (ETDEWEB)

    Mandina, Tania [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Roch-Lefevre, Sandrine H.; Voisin, Pascale [Institut de Radioprotection et de Surete Nucleaire (IRSN), DRPH, SRBE, LDB, BP17, 92262 Fontenay-aux-Roses (France); Gonzalez, Jorge E.; Lamadrid, Ana I.; Romero, Ivonne [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Garcia, Omar, E-mail: omar@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Voisin, Philippe; Roy, Laurence [Institut de Radioprotection et de Surete Nucleaire (IRSN), DRPH, SRBE, LDB, BP17, 92262 Fontenay-aux-Roses (France)

    2011-09-15

    Biological dosimeters are recommended for dose estimation in case of human overexposure to ionising radiation. Rapid measurement of {gamma}-H2AX foci as a marker of DNA double-strand breaks (DSB) induction has been recently tested with this purpose. Here we reported a dose-response relationship after X-ray irradiation at different times post-exposure. Blood samples were obtained from several healthy donors and exposed to doses between 0 and 2 Gy. After irradiation, blood samples were incubated at 37 deg. C during 0.5 h, 5 h, and 8 h. Scoring of cells and {gamma}-H2AX foci was performed by software. The dose-response curves for different incubation times were as follows: Y{sub (0.5h)} = 11.66D + 0.15 (R{sup 2} = 0.99), Y{sub (5h)} = 2.44D + 0.15 (R{sup 2} = 0.99), Y{sub (8h)} = 1.57D + 0.22 (R{sup 2} = 0.99). At 0.5 h post-exposure, the dose-response relationship for X-irradiated lymphocytes was similar to the one obtained after gamma-irradiation using the same protocol. On the other hand, the results were not similar after 8 h due to different kinetics after gamma- and X-irradiation. Our results confirm the possibilities of using {gamma}-H2AX foci method for dose estimation in a period from 0.5 h up to 8 h post X-irradiation and support the hypothesis of differences in {gamma}-H2AX foci kinetics after gamma- and X-irradiation in vitro.

  10. Analysis of patients' X-ray exposure in 146 percutaneous radiologic gastrostomies; Analyse der Strahlenexposition fuer Patienten bei 146 perkutanen radiologischen Gastrostomien

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael [Univ. Hospital Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-09-15

    Analysis of patient's X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. The median DFP of PRG-placements under fluoroscopy was 163 cGy{sup *}cm{sup 2} (flat panel detector systems: 155 cGy{sup *}cm{sup 2}; X-ray image intensifier: 175 cGy{sup *}cm{sup 2}). The median DLZ was 2.2min. Intraprocedural placement of a naso- or orogastric probe (n=68) resulted in a significant prolongation of the median DLZ to 2.5min versus 2min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n=7, median DFP=2635 cGy{sup *}cm{sup 2}), or using CT (n=4, median DLP=657mGy{sup *}cm). Estimates of the median DFP and DLP showed effective doses of 0.3mSv for DL-assisted placements (flat panel detector 0.3mSv, X-ray image converter 0.4mSv), 7.9mSv using a CBCT - flat detector, and 9.9mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the

  11. X-ray radiotherapy

    International Nuclear Information System (INIS)

    Tronc, D.

    1995-01-01

    Full text: The most common form of radio therapy is X-ray therapy, where a beam of photons or their parent electrons break down hydrogen bonds within the body's cells and remove certain DNA information necessary for cell multiplication. This process can eradicate malignant cells leading to complete recovery, to the remission of some cancers, or at least to a degree of pain relief. The radiotherapy instrument is usually an electron linac, and the electrons are used either directly in 'electrotherapy' for some 10% of patients, or the electrons bombard a conversion target creating a broad beam of high energy photons or 'penetration X-rays'. The simplest machine consists of several accelerating sections at around 3 GHz, accelerating electrons to 6 MeV; a cooled tungsten target is used to produce a 4 Gray/min X-ray field which can be collimated into a rectangular shape at the patient position. This tiny linac is mounted inside a rotating isocentric gantry above the patient who must remain perfectly still. Several convergent beams can also be used to increase the delivered dose. More sophisticated accelerators operate at up to 18 MeV to increase penetration depths and decrease skin exposure. Alternatively, electrotherapy can be used with different energies for lower and variable penetration depths - approximately 0.5 cm per MeV. In this way surface tissue may be treated without affecting deeper and more critical anatomical regions. This type of linac, 1 to 2 metres long, is mounted parallel to the patient with a bending magnet to direct the beam to the radiotherapy system, which includes the target, thick movable collimator jaws, a beam field equalizer, dose rate and optical field simulation and energy controls. There are over 2000 acceleratorbased X-ray treatment units worldwide. Western countries have up to two units per million population, whereas in developing countries such as Bangladesh, the density is only one per 100 million. Several

  12. Simulating Valence-to-Core X-ray Emission Spectroscopy of Transition Metal Complexes with Time-Dependent Density Functional Theory.

    Science.gov (United States)

    Zhang, Yu; Mukamel, Shaul; Khalil, Munira; Govind, Niranjan

    2015-12-08

    Valence-to-core (VtC) X-ray emission spectroscopy (XES) has emerged as a powerful technique for the structural characterization of complex organometallic compounds in realistic environments. Since the spectrum represents electronic transitions from the ligand molecular orbitals to the core holes of the metal centers, the approach is more chemically sensitive to the metal-ligand bonding character compared with conventional X-ray absorption techniques. In this paper we study how linear-response time-dependent density functional theory (LR-TDDFT) can be harnessed to simulate K-edge VtC X-ray emission spectra reliably. LR-TDDFT allows one to go beyond the single-particle picture that has been extensively used to simulate VtC-XES. We consider seven low- and high-spin model complexes involving chromium, manganese, and iron transition metal centers. Our results are in good agreement with experiment.

  13. The effect of caffeine on p53-dependent radioresponses in undifferentiated mouse embryonal carcinoma cells after X-ray and UV-irradiations

    International Nuclear Information System (INIS)

    Taga, Masataka; Shiraishi, Kazunori; Shimura, Tsutomu; Uematsu, Norio; Kato, Tomohisa; Niwa, Ohtsura; Nishimune, Yoshitake; Aizawa, Shinichi; Oshimura, Mitsuo

    2000-01-01

    The effect of caffeine was studied on the radioresponses of undifferentiated mouse embryonal carcinoma cells (EC cells) with or without the functional p53. The radioresponses studied included radiosensitivity, the activation of p53, apoptosis with characteristic DNA ladder formation and cell cycle progression. An undifferentiated mouse EC cell line, ECA2, and a newly established p53-deficient EC cell line, p53δ, were used in the present study. The status of the p53 gene did not significantly affect the colony survivals of undifferentiated EC cells to X-rays and UV. Although a post-irradiation treatment with caffeine sensitized both lines to X-rays marginally, the sensitization was prominent for UV regardless of the p53 status of the cells. The activation of a p53 responsible lacZ reporter construct was observed in stably transfected ECA2 cells after X-ray and UV irradiations. Caffeine suppressed the X-ray induced activation of the lacZ reporter, while it drastically enhanced the activation after UV irradiation. X-rays and UV readily triggered the apoptosis of ECA2 cells with the characteristic DNA ladder. Although UV-induced DNA ladder formation was enhanced by caffeine, that induced by X-rays was unaffected. Therefore, the effects of caffeine on the p53-dependent radioresponses were found to be agent specific: suppression for the X-ray induced and augmentation for the UV induced. In contrast to p53-proficient ECA2 cells, smear-like DNA degradation was observed for irradiated p53δ cells, suggesting the presence of a mode of cell death without DNA ladder formation. UV induction of the smear-like DNA degradation was enhanced in the presence of caffeine. Regardless of the state of the p53 gene, G1/S arrest was not observed in X-ray and UV irradiated EC cells. X-rays induced G2/M arrest in both lines, which was abrogated by caffeine, while G2/M arrest after UV was unaffected by a caffeine treatment. These results indicate that the radioresponses of undifferentiated

  14. The effect of caffeine on p53-dependent radioresponses in undifferentiated mouse embryonal carcinoma cells after X-ray and UV-irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Taga, Masataka; Shiraishi, Kazunori; Shimura, Tsutomu; Uematsu, Norio; Kato, Tomohisa; Niwa, Ohtsura [Kyoto Univ. (Japan). Radiation Biology Center; Nishimune, Yoshitake; Aizawa, Shinichi; Oshimura, Mitsuo

    2000-09-01

    The effect of caffeine was studied on the radioresponses of undifferentiated mouse embryonal carcinoma cells (EC cells) with or without the functional p53. The radioresponses studied included radiosensitivity, the activation of p53, apoptosis with characteristic DNA ladder formation and cell cycle progression. An undifferentiated mouse EC cell line, ECA2, and a newly established p53-deficient EC cell line, p53{delta}, were used in the present study. The status of the p53 gene did not significantly affect the colony survivals of undifferentiated EC cells to X-rays and UV. Although a post-irradiation treatment with caffeine sensitized both lines to X-rays marginally, the sensitization was prominent for UV regardless of the p53 status of the cells. The activation of a p53 responsible lacZ reporter construct was observed in stably transfected ECA2 cells after X-ray and UV irradiations. Caffeine suppressed the X-ray induced activation of the lacZ reporter, while it drastically enhanced the activation after UV irradiation. X-rays and UV readily triggered the apoptosis of ECA2 cells with the characteristic DNA ladder. Although UV-induced DNA ladder formation was enhanced by caffeine, that induced by X-rays was unaffected. Therefore, the effects of caffeine on the p53-dependent radioresponses were found to be agent specific: suppression for the X-ray induced and augmentation for the UV induced. In contrast to p53-proficient ECA2 cells, smear-like DNA degradation was observed for irradiated p53{delta} cells, suggesting the presence of a mode of cell death without DNA ladder formation. UV induction of the smear-like DNA degradation was enhanced in the presence of caffeine. Regardless of the state of the p53 gene, G1/S arrest was not observed in X-ray and UV irradiated EC cells. X-rays induced G2/M arrest in both lines, which was abrogated by caffeine, while G2/M arrest after UV was unaffected by a caffeine treatment. These results indicate that the radioresponses of

  15. The influence of plutonium exposure and lung cancer on the frequency of x-ray-induced micronuclei in dog blood lymphocytes

    International Nuclear Information System (INIS)

    Brooks, A.L.; Rithidech, K.; Muggenburg, B.A.; Lozano, D.; Lundgren, D.L.

    1988-01-01

    This study determined if lung cancer or exposure to an inhaled alpha emitter, plutonium-239, increased the frequency of micronuclei in blood lymphocytes or altered the responsiveness of lymphocytes to induction of micronuclei by subsequent doses of X rays in vitro. Beagle dogs inhaled 1.5 mm ABAD monodisperse 239 PuO 2 aerosols. The exposure resulted in initial lung burdens of 1.8 KBq to 48 KBq and produced cumulative alpha radiation lung doses of 1.4 to 10.4 Gy at the time of this study. Blood lymphocytes were sampled and irradiated with either 0.0 or 2.0 Gy of X rays. The lymphocytes were stimulated to divide by phytohemagglutinin, cytokinesis was blocked with cytochalasin B, and the frequency of micronuclei was determined in binucleated cells. Plutonium inhalation alone produced no significant increase in the frequency of micronuclei in blood lymphocytes. When 2 Gy of X rays ws given to blood lymphocytes of dogs that had inhaled 239 PuO 2 , there was a linear increase in micronuclei frequency as a function of alpha dose to the lungs; micronuclei/binucleated cell = 0.15 +0.2 D, where D is the cumulative alpha-radiation dose to the lung in Gy. Dogs with 239 PuO 2 - induced lung cancer did not have a significant increase in the frequency of X- ray-induced micronuclei relative to dogs exposed to plutonium that did not have lung cancer. These data suggest that inhaled 239 PuO 2 alters the responsiveness of blood lymphocytes to subsequent X-ray exposure. (author)

  16. A SEARCH FOR SPECTRAL HYSTERESIS AND ENERGY-DEPENDENT TIME LAGS FROM X-RAY AND TeV GAMMA-RAY OBSERVATIONS OF Mrk 421

    International Nuclear Information System (INIS)

    Abeysekara, A. U.; Flinders, A.; Archambault, S.; Feng, Q.; Archer, A.; Buckley, J. H.; Bugaev, V.; Benbow, W.; Cerruti, M.; Bird, R.; Buchovecky, M.; Cardenzana, J. V; Eisch, J. D.; Chen, X.; Ciupik, L.; Connolly, M. P.; Cui, W.; Finley, J. P.; Falcone, A.; Fleischhack, H.

    2017-01-01

    Blazars are variable emitters across all wavelengths over a wide range of timescales, from months down to minutes. It is therefore essential to observe blazars simultaneously at different wavelengths, especially in the X-ray and gamma-ray bands, where the broadband spectral energy distributions usually peak. In this work, we report on three “target-of-opportunity” observations of Mrk 421, one of the brightest TeV blazars, triggered by a strong flaring event at TeV energies in 2014. These observations feature long, continuous, and simultaneous exposures with XMM-Newton (covering the X-ray and optical/ultraviolet bands) and VERITAS (covering the TeV gamma-ray band), along with contemporaneous observations from other gamma-ray facilities (MAGIC and Fermi -Large Area Telescope) and a number of radio and optical facilities. Although neither rapid flares nor significant X-ray/TeV correlation are detected, these observations reveal subtle changes in the X-ray spectrum of the source over the course of a few days. We search the simultaneous X-ray and TeV data for spectral hysteresis patterns and time delays, which could provide insight into the emission mechanisms and the source properties (e.g., the radius of the emitting region, the strength of the magnetic field, and related timescales). The observed broadband spectra are consistent with a one-zone synchrotron self-Compton model. We find that the power spectral density distribution at ≳4 × 10 −4 Hz from the X-ray data can be described by a power-law model with an index value between 1.2 and 1.8, and do not find evidence for a steepening of the power spectral index (often associated with a characteristic length scale) compared to the previously reported values at lower frequencies.

  17. A SEARCH FOR SPECTRAL HYSTERESIS AND ENERGY-DEPENDENT TIME LAGS FROM X-RAY AND TeV GAMMA-RAY OBSERVATIONS OF Mrk 421

    Energy Technology Data Exchange (ETDEWEB)

    Abeysekara, A. U.; Flinders, A. [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States); Archambault, S.; Feng, Q. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Archer, A.; Buckley, J. H.; Bugaev, V. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W.; Cerruti, M. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Bird, R.; Buchovecky, M. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Cardenzana, J. V; Eisch, J. D. [Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Chen, X. [Institute of Physics and Astronomy, University of Potsdam, D-14476 Potsdam-Golm (Germany); Ciupik, L. [Astronomy Department, Adler Planetarium and Astronomy Museum, Chicago, IL 60605 (United States); Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Cui, W.; Finley, J. P. [Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907 (United States); Falcone, A. [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); Fleischhack, H. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Collaboration: VERITAS Collaboration; MAGIC Collaboration; and others

    2017-01-01

    Blazars are variable emitters across all wavelengths over a wide range of timescales, from months down to minutes. It is therefore essential to observe blazars simultaneously at different wavelengths, especially in the X-ray and gamma-ray bands, where the broadband spectral energy distributions usually peak. In this work, we report on three “target-of-opportunity” observations of Mrk 421, one of the brightest TeV blazars, triggered by a strong flaring event at TeV energies in 2014. These observations feature long, continuous, and simultaneous exposures with XMM-Newton (covering the X-ray and optical/ultraviolet bands) and VERITAS (covering the TeV gamma-ray band), along with contemporaneous observations from other gamma-ray facilities (MAGIC and Fermi -Large Area Telescope) and a number of radio and optical facilities. Although neither rapid flares nor significant X-ray/TeV correlation are detected, these observations reveal subtle changes in the X-ray spectrum of the source over the course of a few days. We search the simultaneous X-ray and TeV data for spectral hysteresis patterns and time delays, which could provide insight into the emission mechanisms and the source properties (e.g., the radius of the emitting region, the strength of the magnetic field, and related timescales). The observed broadband spectra are consistent with a one-zone synchrotron self-Compton model. We find that the power spectral density distribution at ≳4 × 10{sup −4} Hz from the X-ray data can be described by a power-law model with an index value between 1.2 and 1.8, and do not find evidence for a steepening of the power spectral index (often associated with a characteristic length scale) compared to the previously reported values at lower frequencies.

  18. High-resolution molybdenum K-edge X-ray absorption spectroscopy analyzed with time-dependent density functional theory.

    Science.gov (United States)

    Lima, Frederico A; Bjornsson, Ragnar; Weyhermüller, Thomas; Chandrasekaran, Perumalreddy; Glatzel, Pieter; Neese, Frank; DeBeer, Serena

    2013-12-28

    X-ray absorption spectroscopy (XAS) is a widely used experimental technique capable of selectively probing the local structure around an absorbing atomic species in molecules and materials. When applied to heavy elements, however, the quantitative interpretation can be challenging due to the intrinsic spectral broadening arising from the decrease in the core-hole lifetime. In this work we have used high-energy resolution fluorescence detected XAS (HERFD-XAS) to investigate a series of molybdenum complexes. The sharper spectral features obtained by HERFD-XAS measurements enable a clear assignment of the features present in the pre-edge region. Time-dependent density functional theory (TDDFT) has been previously shown to predict K-pre-edge XAS spectra of first row transition metal compounds with a reasonable degree of accuracy. Here we extend this approach to molybdenum K-edge HERFD-XAS and present the necessary calibration. Modern pure and hybrid functionals are utilized and relativistic effects are accounted for using either the Zeroth Order Regular Approximation (ZORA) or the second order Douglas-Kroll-Hess (DKH2) scalar relativistic approximations. We have found that both the predicted energies and intensities are in excellent agreement with experiment, independent of the functional used. The model chosen to account for relativistic effects also has little impact on the calculated spectra. This study provides an important calibration set for future applications of molybdenum HERFD-XAS to complex catalytic systems.

  19. High-speed X-ray topography

    International Nuclear Information System (INIS)

    Eckers, W.; Oppolzer, H.

    1977-01-01

    The investigation of lattice defects in semiconductor crystals by conventional X-ray diffraction topography is very time-consuming. Exposure times can be reduced by using high-intensity X-rays and X-ray image intensifiers. The described system comprises a high-power rotating-anode X-ray tube, a remote-controlled X-ray topography camera, and a television system operating with an X-ray sensing VIDICON. System performance is demonstrated with reference to exploratory examples. The exposure time for photographic plates is reduced to 1/20 and for the X-ray TV system (resolution of the order of 30 μm) to 1/100 relative to that required when using a conventional topography system. (orig.) [de

  20. Low energy (soft) x rays

    International Nuclear Information System (INIS)

    Hoshi, Masaharu; Antoku, Shigetoshi; Russell, W.J.; Miller, R.C.; Nakamura, Nori; Mizuno, Masayoshi; Nishio, Shoji.

    1987-05-01

    Dosimetry of low-energy (soft) X rays produced by the SOFTEX Model CMBW-2 was performed using Nuclear Associates Type 30 - 330 PTW, Exradin Type A2, and Shonka-Wyckoff ionization chambers with a Keithley Model 602 electrometer. Thermoluminescent (BeO chip) dosimeters were used with a Harshaw Detector 2000-A and Picoammeter-B readout system. Beam quality measurements were made using aluminum absorbers; exposure rates were assessed by the current of the X-ray tube and by exposure times. Dose distributions were established, and the average factors for non-uniformity were calculated. The means of obtaining accurate absorbed and exposed doses using these methods are discussed. Survival of V79 cells was assessed by irradiating them with soft X rays, 200 kVp X rays, and 60 Co gamma rays. The relative biological effectiveness (RBE) values for soft X rays with 0, 0.2, 0.7 mm added thicknesses of aluminum were 1.6, which were compared to 60 Co. The RBE of 200 kVp X rays relative to 60 Co was 1.3. Results of this study are available for reference in future RERF studies of cell survival. (author)

  1. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    Science.gov (United States)

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies.

  2. Radioresistant cell strain of human fibrosarcoma cells obtained after long-term exposure to X-rays

    International Nuclear Information System (INIS)

    Wei, K.; Kodym, R.

    1998-01-01

    A radioresistant cell strain from human fibrosarcoma HT1080 has been obtained after prolonged exposure to x-rays for 7 months (2 Gy per day, 5 days per week). This new strain, HT1080R, differs from HT1080 in a significantly increased ability of clonogenical survival, with coefficient α decreasing from 0.161 to 0.123 Gy -1 and coefficient β decreasing from 0.0950 to 0.0565 Gy -2 . Furthermore, the radioresistance of HT1080R proved to be stable in long-term passaged cultures as well as in frozen samples. Differences between the two cell lines are also observed in the G-banded karyotype; the new cell line shows monosomy of chromosome 17 and loss of 5p + and 11q + present in the parental cells. These data suggest that the radioresistance may have been caused by radiation-induced cell mutation and that the resistant cells may have been selected by repeated irradiations. In order to characterize this new strain, the ability of the cells to rejoin DNA double-strand breaks, the cell cycle distribution and the amount of apoptosis after irradiation have been estimated; however, no differences are observed between these two cell strains. Although the mechanism of the elevated radioresistance remains unknown, this pair of cell strains can provide a new model system for further investigations with regard to the mechanisms of cellular radioresistance. The results also show that any type of irradiation similar to the schedules used in radiotherapy can lead to the formation and selection of more radioresistant cell clones in vitro, a phenomenon with possible implications for radiotherapy. (orig.)

  3. 4D synchrotron X-ray imaging to understand porosity development in shales during exposure to hydraulic fracturing fluid

    Science.gov (United States)

    Kiss, A. M.; Bargar, J.; Kohli, A. H.; Harrison, A. L.; Jew, A. D.; Lim, J. H.; Liu, Y.; Maher, K.; Zoback, M. D.; Brown, G. E.

    2016-12-01

    Unconventional (shale) reservoirs have emerged as the most important source of petroleum resources in the United States and represent a two-fold decrease in greenhouse gas emissions compared to coal. Despite recent progress, hydraulic fracturing operations present substantial technical, economic, and environmental challenges, including inefficient recovery, wastewater production and disposal, contaminant and greenhouse gas pollution, and induced seismicity. A relatively unexplored facet of hydraulic fracturing operations is the fluid-rock interface, where hydraulic fracturing fluid (HFF) contacts shale along faults and fractures. Widely used, water-based fracturing fluids contain oxidants and acid, which react strongly with shale minerals. Consequently, fluid injection and soaking induces a host of fluid-rock interactions, most notably the dissolution of carbonates and sulfides, producing enhanced or "secondary" porosity networks, as well as mineral precipitation. The competition between these mechanisms determines how HFF affects reactive surface area and permeability of the shale matrix. The resultant microstructural and chemical changes may also create capillary barriers that can trap hydrocarbons and water. A mechanistic understanding of the microstructure and chemistry of the shale-HFF interface is needed to design new methodologies and fracturing fluids. Shales were imaged using synchrotron micro-X-ray computed tomography before, during, and after exposure to HFF to characterize changes to the initial 3D structure. CT reconstructions reveal how the secondary porosity networks advance into the shale matrix. Shale samples span a range of lithologies from siliceous to calcareous to organic-rich. By testing shales of different lithologies, we have obtained insights into the mineralogic controls on secondary pore network development and the morphologies at the shale-HFF interface and the ultimate composition of produced water from different facies. These results

  4. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams

    International Nuclear Information System (INIS)

    Zeng, G G; McEwen, M R; Rogers, D W O; Klassen, N V

    2004-01-01

    The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60 Co rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electron paramagnetic resonance (EPR) spectra of irradiated pellets were measured using a Bruker EMX 081 EPR spectrometer. The DOSRZnrc Monte Carlo code of the EGSnrc system was used to simulate the experimental conditions with BEAM code calculated input spectra of x-rays and γ-rays. Within the experimental uncertainty of 0.5%, the alanine EPR response to absorbed dose-to-water for x-rays was not dependent on beam quality from 6 MV to 25 MV, but on average, it was about 0.6% lower than its response to 60 Co gamma rays. Combining experimental data with Monte Carlo calculations, it is found that the alanine/EPR response per unit absorbed dose-to-alanine is the same for clinical x-rays and 60 Co gamma rays within the uncertainty of 0.6%. Monte Carlo simulations showed that neither the presence of PMMA holder nor varying the dosimeter thickness between 1 mm and 5 mm has significant effect on the energy dependence of alanine/EPR dosimetry within the calculation uncertainty of 0.3%

  5. Exposure of [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnets to soft X-rays: The effect of the counterions on radiation stability

    Energy Technology Data Exchange (ETDEWEB)

    Helmstedt, Andreas, E-mail: andreas.helmstedt@uni-bielefeld.de [Fakultaet fuer Physik, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Sacher, Marc D.; Gryzia, Aaron; Harder, Alexander; Brechling, Armin; Mueller, Norbert; Heinzmann, Ulrich [Fakultaet fuer Physik, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Hoeke, Veronika; Krickemeyer, Erich; Glaser, Thorsten [Fakultaet fuer Chemie, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Bouvron, Samuel; Fonin, Mikhail [Fachbereich Physik, Universitaet Konstanz, Universitaetsstrasse 10, D-78457 Konstanz (Germany)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnets adsorbed on gold are investigated. Black-Right-Pointing-Pointer The oxidation state of the Mn{sup III} constituents changes under X-ray exposure. Black-Right-Pointing-Pointer The change is monitored by Mn-L{sub 3}-edge XAS. Black-Right-Pointing-Pointer Choice of anions strongly influences radiation stability of the SMM. Black-Right-Pointing-Pointer No influence of the sample morphology on radiation stability could be observed. - Abstract: X-ray absorption spectroscopy studies of the [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnet deposited as a microcrystalline layer on gold substrates are presented. The oxidation state of the manganese centers changes from Mn{sup III} to Mn{sup II} due to irradiation with soft X-rays. The influence of the charge-neutralizing anions on the stability of [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} against soft X-ray exposure is investigated for the different anions tetraphenylborate (BPh{sub 4}{sup -}), lactate (C{sub 3}H{sub 5}O{sub 3}{sup -}) and perchlorate (ClO{sub 4}{sup -}). The exposure dependence of the radiation-induced reduction process is compared for [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} with the three different anions.

  6. [Induction of micronuclei in peripheral blood and bone marrow reticulocytes of male mice after subchronic exposure to x-rays and bisphenol A].

    Science.gov (United States)

    Radzikowska, Joanna; Gajowik, Aneta; Dobrzyńska, Małgorzata

    2012-01-01

    Ionizing radiation and xenoestrogens are widely present in the human environment. Bisphenol A (BPA) is used to manufacture polycarbonate plastics, epoxy and polyester resins. BPA is present in a great variety of products including: baby bottles, compact disks, thermal paper, safety helmets, bullet resistant laminate, plastic windows, car parts, adhesives, protective coatings, powder paints, polycarbonate bottles and containers, the sheathing of electrical and electronic parts, dental fillings. Food and beverage cans are protected from rusting and corrosion by the application of epoxy resins as inner coatings. Human activities involving the use of radiation and radioactive materials in industry, agriculture and research cause radiation exposure in addition to natural exposure coming from cosmic rays and naturally occurring radioactive substances. The aim of the study was to estimate the effects of bisphenol A, X-rays and combined exposure to X-rays and bisphenol A on the induction of micronuclei in the peripheral blood and in bone marrow reticulocytes of laboratory mice. Pzh-Sfis male mice were exposed for 8 weeks. Animals were treated with bisphenol A diluted in drinking water (5 mg/kg bw, 10 mg/kg bw, 20 mg/kg bw), irradiated 0.05 Gy of X-rays or exposed to a combination of both (0.05 Gy + 5 mg/kg bw BPA). The samples of peripheral blood were taken at 1, 4 and 8 week following the start of exposure, whereas the bone marrow after the end of experiment, only. The induction of micronuclei in reticulocytes were evaluated by using fluorescence microscope. Bisphenol A as well as ionizing radiation stimulated induction of micronuclei in peripheral blood and bone marrow reticulocytes. After the irradiation the level of micronuclei increased, whereas after exposure to BPA decreased related to time expired from beginning of experiment. Combined exposure of ionizing radiation and bisphenol A induced significantly higher frequency of micronuclei compared to the effect

  7. Lambda bacteriophage gene products and x-ray sensitivity of Escherichia coli: comparison of red-dependent and gam-dependent radioresistance

    International Nuclear Information System (INIS)

    Trgovcevic, Z.; Rupp, W.D.

    1975-01-01

    When gene products of lambda bacteriophage are introduced into a cell by transient induction of a lysogen, increased resistance of the cells to x rays results. This phenomenon has been called phage-induced radioresistance. Genetic studies show at least two classes of induced radioresistance. The first type depends on the products of the lambda red genes and is observed in bacteria that are mutated in the recB gene. It is thought that the lambda red products compensate for the missing RecBC nuclease in the repair of x-ray damage. An optimal effect is obtained even when the lambda red products are supplied 1 h after irradiation. The lesions that are affected by the red-dependent process are probably not deoxyribonucleic acid strand breaks because the extent of deoxyribonucleic acid strand rejoining is not altered by the red products. The second type of phage-induced radioresistance requires the gam product of lambda and is observed in wild-type and polA strains. The lambda gam + gene product must be present immediately after irradiation to exert its full effect. In its presence, DNA breakdown is decreased, and a greater fraction of DNA is converted back to high molecular weight. Strains carrying lex, recA, or certain other combinations of mutations do not show any detectable phage-induced radioresistance. (U.S.)

  8. A new cell for temperature-dependent X-ray absorption spectroscopy of liquid solutions: application to PbBr2 solutions in diethylene glycol.

    Science.gov (United States)

    Lützenkirchen-Hecht, D; Oldag, T; Keil, P; Keller, H L; Frahm, R

    2005-03-01

    An in situ cell has been constructed for temperature-dependent X-ray absorption experiments (EXAFS and XANES) of lead bromine (PbBr2) solutions in diethylene glycol in the temperature range from room temperature up to about 433 K. The solution is kept in a thermostated container made of carbon-reinforced teflon between two thin chemically inert quartz glass windows with a high transmission for hard X-rays. The construction of the cell ensures that these X-ray windows are thermalized so that any possible precipitation of solid products from the solution is inhibited. The cell consists mainly of two hermetically sealed teflon containers for the thermostating fluid (silicon oil) that were fitted together in such a way that a small and variable volume (approximately 2-4 cm3) for the liquid under investigation was achieved. A small thermocouple in a glass enclosure was placed in the solution to maintain temperature control and feedback to the thermostat. The cell design and its performance for temperature-dependent in situ investigations with X-rays are reported. Some preliminary results obtained for PbBr2 solutions in diethylene glycol are given.

  9. Estimation of the effective energy for the diagnostic X-ray

    International Nuclear Information System (INIS)

    Ogama, Noboru; Fujimoto, Nobuhisa; Nishitani, Motohiro; Yamada, Katsuhiko

    2001-01-01

    Because X-ray exposure doses to patients during X-ray diagnoses have been increasing with recent advances in medical technology, it is important that optimum control of the radiation dose be maintained during diagnoses. For an evaluation of an exposure dose, the effective energy of the X-ray must be determined, but this is difficult to accomplish during the diagnosis. Here we propose a new method to estimate the effective energy of an X-ray. The magnitude of energy released from an X-ray generator (2 peaks, 12 peaks, inverter, and constant potential) depends on various parameters, including tube voltage, tube current, tube voltage waveform, and total filtration of the X-ray tube. Therefore the measurement of an X-ray's effective energy was conducted by the half-value layer measurement method, which changes the values of these parameters. The data obtained by this method were analyzed to clarify the relationships between X-ray effective energy and the respective parameters. It was thus demonstrated that these relationships could be expressed by a simple linear approximation formula. For the calculation of X-ray effective energy by use of this approximation formula, errors were found to be within a range of -2.11% to 10.4%. Therefore, this method is considered usable for an accurate estimation of an X-ray's effective energy without the need for its direct determination during diagnosis. (author)

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  12. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  13. Influence of occupational exposure to pesticides on the level of DNA damage induced in human lymphocytes (Polish group) by UV-C and X-rays

    International Nuclear Information System (INIS)

    Dyga, W.; Drag, Z.; Cebulska-Wasilewska, A.

    2002-01-01

    The aim of this study was to find out whether occupational exposure to pesticides might affect the individual susceptibility of various donors to the induction of DNA damage by genotoxic agents (UV-C, X-rays) and the efficiency of cellular repair. Previously cryo preserved lymphocytes were defrosted, and DNA damage in the lymphocytes prior to any in vitro studies was investigated with the application of the Comet assay. In order to evaluate the susceptibilities of human lymphocytes to genotoxic agents and the variability of repair capacities, the DNA migrations were estimated immediately after exposure to UV-C light or X-rays and after two hours. On average, the DNA damage detected in untreated lymphocytes was significantly higher in the group exposed to pesticides than in reference group. UV-C treated lymphocytes from group exposed to pesticides shows a greater statistically significant level of DNA migration compared to the reference group, detected after 2 hours incubation in the absence of PHA. Significantly lower responses to X-rays and higher levels of residual DNA damage were detected in the lymphocytes of donors from the group exposed to pesticides compared with the reference group. In conclusion, our results suggest that occupational exposure to pesticides influences the level of induced DNA damage, and the cellular capabilities of repair. (author)

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  16. Enhanced neoplastic transformation by mammography X rays relative to 200 kVp X rays: indication for a strong dependence on photon energy of the RBE(M) for various end points.

    Science.gov (United States)

    Frankenberg, D; Kelnhofer, K; Bär, K; Frankenberg-Schwager, M

    2002-01-01

    The fundamental assumption implicit in the use of the atomic bomb survivor data to derive risk estimates is that the gamma rays of Hiroshima and Nagasaki are considered to have biological efficiencies equal to those of other low-LET radiations up to 10 keV/microm, including mammography X rays. Microdosimetric and radiobiological data contradict this assumption. It is therefore of scientific and public interest to evaluate the efficiency of mammography X rays (25-30 kVp) to induce cancer. In this study, the efficiency of mammography X rays relative to 200 kVp X rays to induce neoplastic cell transformation was evaluated using cells of a human hybrid cell line (CGL1). For both radiations, a linear-quadratic dose-effect relationship was observed for neoplastic transformation of CGL1 cells; there was a strong linear component for the 29 kVp X rays. The RBE(M) of mammography X rays relative to 200 kVp X rays was determined to be about 4 for doses energies of transformation of CGL1 cells. Both the data available in the literature and the results of the present study strongly suggest an increase of RBE(M) for carcinogenesis in animals, neoplastic cell transformation, and clastogenic effects with decreasing photon energy or increasing LET to an RBE(M) approximately 8 for mammography X rays relative to 60Co gamma rays.

  17. Time-dependent, x-ray spectral unfolds and brightness temperatures for intense Li+ ion beam-driven hohlraums

    International Nuclear Information System (INIS)

    Fehl, D.L.; Chandler, G.A.; Biggs, F.; Dukart, R.J.; Moats, A.R.; Leeper, R.J.

    1996-01-01

    X-ray-producing hohlraums are being studied as indirect drives for Inertial Confinement Fusion targets. In a 1994 target series on the PBFAII accelerator, cylindrical hohlraum targets were heated by an intense Li + ion beam and viewed by an array of 13 time-resolved, filtered x-ray detectors (XRDs). The UFO unfold code and its suite of auxiliary functions were used extensively in obtaining time- resolved x-ray spectra and radiation temperatures from this diagnostic. UFO was also used to obtain fitted response functions from calibration data, to simulate data from blackbody x-ray spectra of interest, to determine the suitability of various unfolding parameters (e.g., energy domain, energy partition, smoothing conditions, and basis functions), to interpolate the XRD signal traces, and to unfold experimental data. The simulation capabilities of the code were useful in understanding an anomalous feature in the unfolded spectra at low photon energies (≤ 100 eV). Uncertainties in the differential and energy-integrated unfolded spectra were estimated from uncertainties in the data. The time-history of the radiation temperature agreed well with independent calculations of the wall temperature in the hohlraum

  18. Time-dependent, x-ray spectral unfolds and brightness temperatures for intense Li+ ion beam-driven hohlraums

    International Nuclear Information System (INIS)

    Fehl, D.L.; Chandler, G.A.; Biggs, F.; Dukart, R.J.; Moats, A.R.; Leeper, R.J.

    1997-01-01

    X-ray-producing hohlraums are being studied as indirect drives for inertial confinement fusion targets. In a 1994 target series on the PBFAII accelerator, cylindrical hohlraum targets were heated by an intense Li + ion beam and viewed by an array of 13 time-resolved, filtered x-ray detectors (XRDs). The unfold operator (UFO) code and its suite of auxiliary functions were used extensively in obtaining time-resolved x-ray spectra and radiation temperatures from this diagnostic. The UFO was also used to obtain fitted response functions from calibration data, to simulate data from blackbody x-ray spectra of interest, to determine the suitability of various unfolding parameters (e.g., energy domain, energy partition, smoothing conditions, and basis functions), to interpolate the XRD signal traces, and to unfold experimental data. The simulation capabilities of the code were useful in understanding an anomalous feature in the unfolded spectra at low photon energies (≤100 eV). Uncertainties in the differential and energy-integrated unfolded spectra were estimated from uncertainties in the data. The time endash history of the radiation temperature agreed well with independent calculations of the wall temperature in the hohlraum. copyright 1997 American Institute of Physics

  19. Time dependent auto-correlation, autospectrum and decay ratio estimation of transient signals in JET soft X-ray records

    International Nuclear Information System (INIS)

    Por, G.

    1999-08-01

    A program package was developed to estimate the time dependent auto-correlation function (ACF) from the time signals of soft X-ray records taken along the various lines-of-sights in JET-SHOTS, and also to estimate the time dependent Decay Ratio (DR) from that. On the basis of ACF the time dependent auto-power spectral density (APSD) was also calculated. The steps and objectives of this work were: eliminating the white detection noise, trends and slow variation from the time signals, since ordinary methods can give good estimate of the time dependent ACF and DR only for 'nearly' stationary signals, developing an automatic algorithm for finding the maxima and minima of ACF, since they are the basis for DR estimation, evaluating and testing different DR estimators for JET-SHOT, with the aim of finding parts of the signals, where the oscillating character is strong, estimating time dependent ACF and APSD that can follow the relatively fast variation in the time signal. The methods that we have developed for data processing of transient signals are: White detection noise removal and preparation for trend removal - weak components, white detection noise and high frequency components are filtered from the signal using the so-called soft-threshold wavelet filter. Removal of trends and slow variation - Three-point differentiation of the pre-filtered signal is used to remove trends and slow variation. Here we made use of the DERIV function of IDL program language. This leads to a filtered signal that has zero mean value in each time step. Calculation of the time dependent ACF - The signal treated by the two previous steps is used as the input. Calculated ACF value is added in each new time step, but the previously accumulated ACF value is multiplied by a weighting factor. Thus the new sample has 100% contribution, while the contributions from the previous samples are forgotten quickly. DR calculation - DR is a measure of the decay of oscillating ACF. This parameter was shown

  20. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    International Nuclear Information System (INIS)

    Faria, Rita; McKenna, Claire; Wade, Ros; Yang, Huiqin; Woolacott, Nerys; Sculpher, Mark

    2013-01-01

    Objectives: To evaluate the cost-effectiveness of the EOS ® 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS ® to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS ® is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS ® is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS ® is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS ® . The health benefits from radiation dose reductions are very small. Unless EOS ® can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness

  1. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Rita, E-mail: rita.nevesdefaria@york.ac.uk [Centre for Health Economics, University of York, York (United Kingdom); McKenna, Claire [Centre for Health Economics, University of York, York (United Kingdom); Wade, Ros; Yang, Huiqin; Woolacott, Nerys [Centre for Reviews and Dissemination, University of York, York (United Kingdom); Sculpher, Mark [Centre for Health Economics, University of York, York (United Kingdom)

    2013-08-15

    Objectives: To evaluate the cost-effectiveness of the EOS{sup ®} 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS{sup ®} to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS{sup ®} is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS{sup ®} is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS{sup ®} is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS{sup ®}. The health benefits from radiation dose reductions are very small. Unless EOS{sup ®} can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness.

  2. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  3. Radiation-hygienic assessment of theroid exposure in children resulted from X-ray examination of chest organs

    International Nuclear Information System (INIS)

    Kostenetskij, M.I.

    1983-01-01

    Radiation doses for thyroid in children in the case of X-ray examination of chest organs with the aim of optimization of investigation regimes are studied. Dosimetric measurements are performed in aqueous plexiglass phantoms imitating children of different age. It is shown that the maximum radiation dose for thyroid is registered in breast-fed children and constitutes, about 50% of the annual radiation background; in the older age it constiturotes 8-10% of the natural annual radiation backgund. The increase of intensity at the X-ray tube with the simultaneous decrease of explosure in the case of constant filtration of radiation gives the increase of radiation dose of thyroid in breast-fed children are inconsiderable; in older children, approximately in 1.7 times

  4. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, A. [Arbeitsgruppe Aufklarung der Arbeitsplatzverhaltnisse Radar, Wehrbereichsverwaltung Nord, Bundeswehr, Munster (Germany)

    2006-07-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H{sup *}(10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  5. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    International Nuclear Information System (INIS)

    Schirmer, A.

    2006-01-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H * (10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  6. Structural and histochemical considerations of parotid gland from adult rats (Holtzmann) submitted to x-rays exposure

    International Nuclear Information System (INIS)

    Sposto, M.R.

    1988-01-01

    A histomorphological and histochemical study of the parotid gland of adult rats was carried out after subjecting the animals to a single X-ray irradiation dose of 900 R directed to the cervical region. The samples for the histological analysis were obtained at 2, 7, 15, 21, 30 and 45 days after radiation through desiccation and removal of the glands. The results showed clearly that the parotid gland is quite sensitive to X-ray irradiation with the serous acinar cells presenting heavier injuries than the mucous ones. A maximum in the deleterial action of the irradiation was detected at 15 days during the observation period. A comparative analysis of the glandular ducts showed that both of the types intercalated and striated were damaged, with the last presenting severe alterations in morphology and volume. By interpretation of the histochemical results it was concluded that a reduction in protein metabolism of the parotid gland occurred as a consequence of the X-ray irradiation. (author)

  7. arXiv Energy Dependent Features of X-ray Signals in a GridPix Detector

    CERN Document Server

    Krieger, Christoph; Vafeiadis, Theodoros; Desch, Klaus

    2018-06-11

    We report on the calibration of an argon/isobutane (97.7%/2.3%)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy resolution of the detector using both the number of pixels hit and the total measured charge as energy measures. For the latter, the energy resolution σE∕E is better than 10% (20%) for energies above 2 keV (0.5 keV). Several characteristics of the recorded events are studied.

  8. Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography on the optical forward problem.

    Science.gov (United States)

    Hyde, Damon; Schulz, Ralf; Brooks, Dana; Miller, Eric; Ntziachristos, Vasilis

    2009-04-01

    Hybrid imaging systems combining x-ray computed tomography (CT) and fluorescence tomography can improve fluorescence imaging performance by incorporating anatomical x-ray CT information into the optical inversion problem. While the use of image priors has been investigated in the past, little is known about the optimal use of forward photon propagation models in hybrid optical systems. In this paper, we explore the impact on reconstruction accuracy of the use of propagation models of varying complexity, specifically in the context of these hybrid imaging systems where significant structural information is known a priori. Our results demonstrate that the use of generically known parameters provides near optimal performance, even when parameter mismatch remains.

  9. Size-dependent structural disorder in nanocrystalline Cu probed by synchrotron-based X-ray techniques

    International Nuclear Information System (INIS)

    Johannessen, B.; Kluth, P.; Cookson, D.J.; Foran, G.J.; Ridgway, M.C.

    2006-01-01

    Elemental Cu nanocrystals were synthesized in thin film SiO 2 by ion implantation and thermal annealing. The local atomic structure and nanocrystal size distribution were investigated by means of extended X-ray absorption fine structure (EXAFS) spectroscopy and small angle X-ray scattering (SAXS), respectively. We quantify the bondlength contraction and increased structural disorder in the nanocrystals as compared to a bulk Cu reference. Both are proportional to the inverse of the nanocrystal diameter, which in turn is proportional to the surface-area-to-volume ratio. In particular we show that a simple liquid-drop model can explain the bondlength contraction and estimate the surface tension of nanocrystalline Cu to be 3.8 ± 0.4 J/m 2

  10. Sulfur K-edge X-ray absorption spectroscopy and time-dependent density functional theory of arsenic dithiocarbamates.

    Science.gov (United States)

    Donahue, Courtney M; Pacheco, Juan S Lezama; Keith, Jason M; Daly, Scott R

    2014-06-28

    S K-edge X-ray absorption spectroscopy (XAS) and time-dependent density functional theory (TDDFT) calculations were performed on a series of As[S2CNR2]3 complexes, where R2 = Et2, (CH2)5 and Ph2, to determine how dithiocarbamate substituents attached to N affect As[S2CNR2]3 electronic structure. Complimentary [PPh4][S2CNR2] salts were also studied to compare dithiocarbamate bonding in the absence of As. The XAS results indicate that changing the orientation of the alkyl substituents from trans to cis (R2 = Et2vs. (CH2)5) yields subtle variations whereas differences associated with a change from alkyl to aryl are much more pronounced. For example, despite the differences in As 4p mixing, the first features in the S K-edge XAS spectra of [PPh4][S2CNPh2] and As[S2CNPh2]3 were both shifted by 0.3 eV compared to their alkyl-substituted derivatives. DFT calculations revealed that the unique shift observed for [PPh4][S2CNPh2] is due to phenyl-induced splitting of the π* orbitals delocalized over N, C and S. A similar phenomenon accounts for the shift observed for As[S2CNPh2]3, but the presence of two unique S environments (As-S and As···S) prevented reliable analysis of As-S covalency from the XAS data. In the absence of experimental values, DFT calculations revealed a decrease in As-S orbital mixing in As[S2CNPh2]3 that stems from a redistribution of electron density to S atoms participating in weaker As···S interactions. Simulated spectra obtained from TDDFT calculations reproduce the experimental differences in the S K-edge XAS data, which suggests that the theory is accurately modeling the experimental differences in As-S orbital mixing. The results highlight how S K-edge XAS and DFT can be used cooperatively to understand the electronic structure of low symmetry coordination complexes containing S atoms in different chemical environments.

  11. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  12. Energy dependence of photon-induced L shell x-ray intensity ratios in Ta and W

    Energy Technology Data Exchange (ETDEWEB)

    Shatendra, K; Allawadhi, K L; Sood, B S

    1984-02-01

    The L shell x-ray intensity ratios have been measured for the elements Ta and W by photoionization of L shell electrons in the photon energy region 14 <= E <= 44 keV. The experimental results are compared with those calculated at the photon energies used in the present measurements. The measured values show fairly good agreement with the calculated values within the experimental uncertainties. 11 references, 7 figures.

  13. Energy dependence of Lα-to-Ll x-ray intensity ratios for Yb and Pb produced by heavy-ion bombardment

    International Nuclear Information System (INIS)

    Gray, T.J.

    1980-01-01

    Measurements of the incident-ion energy dependence of Lα-to-Ll x-ray intensity ratios are reported for protons incident at 0.40 to 2.20 MeV/amu on thin targets of Pb and for 4 He and C ions incident upon Yb. The data are compared to calculations of the Lα-to-Ll ratio which include the effects of alignment of the 2p/sub 3/2/ state of the target

  14. Variable H13CO+ Emission in the IM Lup Disk: X-Ray Driven Time-dependent Chemistry?

    Science.gov (United States)

    Cleeves, L. Ilsedore; Bergin, Edwin A.; Öberg, Karin I.; Andrews, Sean; Wilner, David; Loomis, Ryan

    2017-07-01

    We report the first detection of a substantial brightening event in an isotopologue of a key molecular ion, HCO+, within a protoplanetary disk of a T Tauri star. The H13CO+ J=3-2 rotational transition was observed three times toward IM Lup between 2014 July and 2015 May with the Atacama Large Millimeter/submillimeter Array. The first two observations show similar spectrally integrated line and continuum fluxes, while the third observation shows a doubling in the disk-integrated J=3-2 line flux compared to the continuum, which does not change between the three epochs. We explore models of an X-ray active star irradiating the disk via stellar flares, and find that the optically thin H13CO+ emission variation can potentially be explained via X-ray-driven chemistry temporarily enhancing the HCO+ abundance in the upper layers of the disk atmosphere during large or prolonged flaring events. If the HCO+ enhancement is indeed caused by an X-ray flare, future observations should be able to spatially resolve these events and potentially enable us to watch the chemical aftermath of the high-energy stellar radiation propagating across the face of protoplanetary disks, providing a new pathway to explore ionization physics and chemistry, including electron density, in disks.

  15. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  16. X-ray simulation development

    International Nuclear Information System (INIS)

    Posey, L.D.; Tollefsrud, P.B.; Woodall, H.W.; McDaniel, D.H.; Allred, R.E.

    1975-01-01

    Design modifications are discussed for an electron beam accelerator used as a Bremsstrahlung x-ray source. The primary goal of the program, to obtain a reliable 5 cal/gm exposure capability, can be accomplished with beam compression by an external magnetic guide field. Initial operating characteristics and performance improvements are presented

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  19. X-ray table

    International Nuclear Information System (INIS)

    Craig, J.R.; Otto, G.W.

    1980-01-01

    An X-ray radiographic or fluoroscopic table is described which includes a film holder with a frame attached to a cable running over end pulleys for positioning the holder longitudinally as desired under the table top. The holder has a front opening to receive a cassette-supporting tray which can be slid out on tracks to change the cassette. A reed switch on the frame is opened by a permanent magnet on the tray only when the tray is half-way out. When the switch is closed, an electromagnet locks the pulley and the holder in place. The holder is thus automatically locked in place not only during exposure (tray in) but when the tray is out for changing the cassette. To re-position the holder, the operator pulls the tray half-out and, using the tray itself, pushes the holder along the table, the holder being counterbalanced by a weight. (author)

  20. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  1. Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants

    International Nuclear Information System (INIS)

    Schneider, Karl; Seidenbusch, M.C.

    2010-01-01

    Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last 30 years by a factor of 5 to 8. They are far below the entrance dose values reported by other radiology departments in Europe. Nevertheless, a slight increase in the entrance doses that correlates with the introduction of a digital storage phosphor system could be observed in the last years. Conclusion: because nearly all radiosensitive body organs in early life are involved during a thoracoabdominal babygram and because of the high radiation sensitivity of newborns, thoracoabdominal babygrams should be performed in neonatology with caution. A dose value of 1.0 cGy cm 2 could serve as the actual reference dose value for the thoracoabdominal babygram of the newborn. (orig.)

  2. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  3. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  4. In vivo x-ray fluorescence of bone lead in the study of human lead metabolism: Serum lead, whole blood lead, bone lead, and cumulative exposure

    International Nuclear Information System (INIS)

    Cake, K.M.; Chettle, D.R.; Webber, C.E.; Gordon, C.L.

    1995-01-01

    Traditionally, clinical studies of lead's effect on health have relied on blood lead levels to indicate lead exposure. However, this is unsatisfactory because blood lead levels have a half-life of approximately 5 weeks, and thus reflect recent exposure. Over 90% of the lead body burden is in bone, and it is thought to have a long residence time, thus implying that measurements of bone lead reflect cumulative exposure. So, measurements of bone lead are useful in understanding the long-term health effects of lead. Ahlgren reported the first noninvasive measurements of bone lead in humans, where γ-rays from 57 Co were used to excite the K series x-rays of lead. The lead detection system at McMaster University uses a 109 Cd source which is positioned at the center of the detector face (HPGe) and a near backscatter (∼160 degrees) geometry. This arrangement allows great flexibility, since one can sample lead in a range of different bone sites due to a robust normalization technique which eliminates the need to correct for bone geometry, thickness of overlying tissue, and other related factors. The effective radiation dose to an adult during an x-ray fluorescence bone lead measurement is extremely low, being 35 nSv. This paper addresses the issue of how bone, whole blood, and serum lead concentrations can be related in order to understand a person's lead exposure history

  5. Image analysis in x-ray cinefluorography

    Energy Technology Data Exchange (ETDEWEB)

    Ikuse, J; Yasuhara, H; Sugimoto, H [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-02-01

    For the cinefluorographic image in the cardiovascular diagnostic system, the image quality is evaluated by means of MTF (Modulation Transfer Function), and object contrast by introducing the concept of x-ray spectrum analysis. On the basis of these results, further investigation is made of optimum X-ray exposure factors set for cinefluorography and the cardiovascular diagnostic system.

  6. Tests for radiation protection in X-Ray mammography room for professional and non-professional exposure

    International Nuclear Information System (INIS)

    Naidenov, I.; Skocheva, A.

    2006-01-01

    Full text: Control tests for radiation protection of medical diagnostic rooms in our country are based on the guidelines to the use of x-rays in medicine and on the basic safety standards for radiation protection. The mammography room tests are not supported by basic data (such as normal conditions for testing and secondary limits) which to allow the developing of methods as the case is with the conventional x-ray rooms. The material presents and discusses over the situation of the matter with the aim to find solution of the problem. In mammography units the space distribution of the dose field of the object scattering radiation is not symmetrical, the maximum being in a direction opposite to the primary beam. Control tests were made for stray radiation in major (in the plane of beam rotation) test points in five rooms with mammography units of different producers and generation, under angles of scattering from the direction of the beam of 900 (horizontal table - 0 deg projection) and 1630 (tilt table - 730 deg projection). The results on the stray radiation show up to four times higher values in the 730 projection, the remaining conditions being the same. Normalization to the week loading used in the shielding design, like the comparison with secondary limits as published in the available norms do not give unambiguous idea. It is advisable to use this projection in control tests for radiation protection and the values shall be compared with the secondary limits of the corresponding standard loading

  7. Time-dependent wave front propagation simulation of a hard x-ray split-and-delay unit: Towards a measurement of the temporal coherence properties of x-ray free electron lasers

    Directory of Open Access Journals (Sweden)

    S. Roling

    2014-11-01

    Full Text Available For the European x-ray free electron laser (XFEL a split-and-delay unit based on geometrical wavefront beam splitting and multilayer mirrors is built which covers the range of photon energies from 5 keV up to 20 keV. Maximum delays between Δτ=±2.5  ps at hν=20  keV and up to Δτ=±23  ps at hν=5  keV will be possible. Time-dependent wave-optics simulations have been performed by means of Synchrotron Radiation Workshop software for XFEL pulses at hν=5  keV. The XFEL radiation was simulated using results of time-dependent simulations applying the self-amplified spontaneous emission code FAST. Main features of the optical layout, including diffraction on the beam splitter edge and optics imperfections measured with a nanometer optic component measuring machine slope measuring profiler, were taken into account. The impact of these effects on the characterization of the temporal properties of XFEL pulses is analyzed. An approach based on fast Fourier transformation allows for the evaluation of the temporal coherence despite large wavefront distortions caused by the optics imperfections. In this way, the fringes resulting from time-dependent two-beam interference can be filtered and evaluated yielding a coherence time of τ_{c}=0.187  fs (HWHM for real, nonperfect mirrors, while for ideal mirrors a coherence time of τ_{c}=0.191  fs (HWHM is expected.

  8. Polarization-dependent force driving the Eg mode in bismuth under optical excitation: comparison of first-principles theory with ultra-fast x-ray experiments

    Science.gov (United States)

    Fahy, Stephen; Murray, Eamonn

    2015-03-01

    Using first principles electronic structure methods, we calculate the induced force on the Eg (zone centre transverse optical) phonon mode in bismuth immediately after absorption of a ultrafast pulse of polarized light. To compare the results with recent ultra-fast, time-resolved x-ray diffraction experiments, we include the decay of the force due to carrier scattering, as measured in optical Raman scattering experiments, and simulate the optical absorption process, depth-dependent atomic driving forces, and x-ray diffraction in the experimental geometry. We find excellent agreement between the theoretical predictions and the observed oscillations of the x-ray diffraction signal, indicating that first-principles theory of optical absorption is well suited to the calculation of initial atomic driving forces in photo-excited materials following ultrafast excitation. This work is supported by Science Foundation Ireland (Grant No. 12/IA/1601) and EU Commission under the Marie Curie Incoming International Fellowships (Grant No. PIIF-GA-2012-329695).

  9. Overutilization of x-rays

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1979-01-01

    In this article on the overutilization of x-rays the author defines the term overutilization as excessive irradiation per unit of diagnostic information, therapeutic impact, or health outcome. Three main factors are described which lead to overutilization of x-rays: excessive radiation per film; excessive films per examination; and excessive examinations per patient. Topics discussed which influence the excessive examinations per patient are: the physician's lack of knowledge; undue dependence; lack of screening by radiologists; the physician's need for action and certainty; patient demand; reimbursement policies; institutional requirements; preventive medicine; defensive medicine; and the practice of radiology by nonradiologists

  10. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  11. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  12. X-rays utilization

    International Nuclear Information System (INIS)

    Rebigan, F.

    1979-03-01

    The modality of X-ray utilization in different activities and economy is given. One presents firstly quantities and units used in radiation dosimetry and other fields. One gives the generation of X-rays, their properties as well as the elements of radiation protection. The utilization characteristics of these radiations in different fields are finally given. (author)

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  14. Perpendicular magnetic anisotropy at the interface between ultrathin Fe film and MgO studied by angular-dependent x-ray magnetic circular dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Okabayashi, J. [Research Center for Spectrochemistry, The University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan); Koo, J. W.; Mitani, S. [National Institute for Materials Science (NIMS), Tsukuba 305-0047 (Japan); Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba 305-8577 (Japan); Sukegawa, H. [National Institute for Materials Science (NIMS), Tsukuba 305-0047 (Japan); Takagi, Y.; Yokoyama, T. [Institute of Molecular Science, Okazaki, Aichi 444-8585 (Japan)

    2014-09-22

    Interface perpendicular magnetic anisotropy (PMA) in ultrathin Fe/MgO (001) has been investigated using angular-dependent x-ray magnetic circular dichroism (XMCD). We found that anisotropic orbital magnetic moments deduced from the analysis of XMCD contribute to the large PMA energies, whose values depend on the annealing temperature. The large PMA energies determined from magnetization measurements are related to those estimated from the XMCD and the anisotropic orbital magnetic moments through the spin-orbit interaction. The enhancement of anisotropic orbital magnetic moments can be explained mainly by the hybridization between the Fe 3d{sub z}{sup 2} and O 2p{sub z} states.

  15. TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Errico, A; Behrman, R; Li, B [Boston University Medical Center, Boston, MA (United States)

    2016-06-15

    Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

  16. TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

    International Nuclear Information System (INIS)

    Errico, A; Behrman, R; Li, B

    2016-01-01

    Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

  17. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  18. Reproductive ability of female dogs (beagles) surviving a single, midlethal, whole-body x-ray exposure

    International Nuclear Information System (INIS)

    Andersen, A.C.; Rosenblatt, L.S.

    1976-01-01

    The ability of 82 irradiated and sham-treated female beagles to whelp and wean pups was tested over a major portion of their reproductive life span. The dogs were exposed to 290 or 300 R of x rays (250 kVp) either as young pups, prior to puberty, or at puberty. Although all of the irradiated dogs were fertile and produced approximately the same number of litters as controls, litters of the pup irradiated and prepubertal irradiated dams surviving throughout the study were smaller than those of controls by 17 and 9 percent, respectively. Pup survival was also reduced relative to controls; the number of pups weaned was 38 percent lower in the pup irradiated group and 18 percent lower in the prepubertal irradiated group, as compared with controls. The overall reproductive ability of dogs irradiated at puberty was similar to that of sham-treated controls

  19. Iron distribution in cancer cells following doxorubicin exposure using proton and X-ray synchrotron radiation microprobes

    International Nuclear Information System (INIS)

    Ortega, R.; Deves, G.; Bohic, S.; Simionovici, A.; Menez, B.; Bonnin-Mosbah, M.

    2001-01-01

    Chemical studies have shown that doxorubicin, a well-established anticancer agent, is a powerful iron chelator and the resultant iron-drug complex is an efficient catalyst of the conversion of hydrogen peroxide to the highly reactive hydroxyl radical. However, the intracellular complexation of doxorubicin with iron is still debated. Using nuclear microprobe analysis (NMPA), we previously observed in human ovarian cancer cells exposed to 20 μM iodo-doxorubicin (IDX) that iodine and iron cellular distributions were spatially correlated, suggesting a mechanism of intracellular iron chelation by the anthracycline compound. Because maximal plasma drug concentrations in patients are expected to be around 5 μM, NMPA and X-ray absorption near edge spectroscopy (XANES) experiments for iron speciation analysis were performed on cultured cells exposed to pharmacological doses of 2 μM IDX or doxorubicin

  20. Behavior analysis in consumer affairs: encouraging dental professionals to provide consumers with shielding from unnecessary X-ray exposure

    International Nuclear Information System (INIS)

    Greene, B.F.; Neistat, M.D.

    1983-01-01

    An unobtrusive observation system was developed to determine the extent to which dental professionals in two communities provided lead shielding to patients during X-ray exams. A lengthy baseline revealed low and irregular provision of shielding among half of these professionals. Subsequently, a program was undertaken by a consumer's group in which these professionals were requested to provide shielding and were given confidential feedback regarding its use during the baseline period. The provision of shielding dramatically increased at all offices and was maintained throughout a follow-up period extending to more than 9 months after the program's implementation. Little or no generalized effect was observed in the occurrence of three collateral behaviors that were also assessed throughout the study

  1. X-rays from supernova 1987A

    International Nuclear Information System (INIS)

    Xu, Y.; Sutherland, P.; Mccray, R.; Ross, R.R.

    1988-01-01

    Detailed calculations of the development of the X-ray spectrum of 1987A are presented using more realistic models for the supernova composition and density structure provided by Woosley. It is shown how the emergence of the X-ray spectrum depends on the parameters of the model and the nature of its central energy source. It is shown that the soft X-ray spectrum should be dominated by a 6.4 keV Fe K(alpha) emission line that could be observed by a sensitive X-ray telescope. 28 references

  2. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  3. Dose Matters: FDA's Guidance on Children's X-rays

    Science.gov (United States)

    ... Consumer Updates Dose Matters: FDA's Guidance on Children's X-rays Share Tweet Linkedin Pin it More sharing options ... exposure during medical procedures. The level of ionizing radiation from X-ray imaging is generally very low, but can ...

  4. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  5. Stellar X-ray sources

    International Nuclear Information System (INIS)

    Katz, J.I.; Washington Univ., St. Louis, MO

    1988-01-01

    I Review some of the salient accomplishments of X-rap studies of compact objects. Progress in this field has closely followed the improvement of observational methods, particularly in angular resolution and duration of exposure. Luminous compact X-ray sources are accreting neutron stars or black holes. Accreting neutron stars may have characteristic temporal signatures, but the only way to establish that an X-ray source is a black hole is to measure its mass. A rough phenomenological theory is succesful, but the transport of angular momentum in accretion flows is not onderstood. A number of interesting complications have been observed, including precessing accretion discs, X-ray bursts, and the acceleration of jets in SS433. Many puzzles remain unsolved, including the excitation of disc precession, the nature of the enigmatic A- and gamma-ray source Cyg X-3, the mechanism by which slowly spinning accreting neutron stars lose angular momentum, and the superabundance of X-ray sources in globular clusters. 41 refs.; 5 figs

  6. Evidence for momentum-dependent heavy-fermionic electronic structures: Soft x-ray ARPES for the superconductor CeNi2Ge2 in the normal state

    Science.gov (United States)

    Nakatani, Y.; Aratani, H.; Fujiwara, H.; Mori, T.; Tsuruta, A.; Tachibana, S.; Yamaguchi, T.; Kiss, T.; Yamasaki, A.; Yasui, A.; Yamagami, H.; Miyawaki, J.; Ebihara, T.; Saitoh, Y.; Sekiyama, A.

    2018-03-01

    We present clear experimental evidence for the momentum-dependent heavy fermionic electronic structures of the 4 f -based strongly correlated system CeNi2Ge2 by soft x-ray angle-resolved photoemission spectroscopy. A comparison between the experimental three-dimensional quasiparticle dispersion of LaNi2Ge2 and CeNi2Ge2 has revealed that heavy fermionic electronic structures are seen in the region surrounding a specific momentum. Furthermore, the wave vectors between the observed "heavy spots" are consistent with a result of neutron scattering reflecting magnetic correlations, which could be a trigger for the superconductivity in CeNi2Ge2 .

  7. State-dependent electron delocalization dynamics at the solute-solvent interface: soft-x-ray absorption spectroscopy and ab initio calculations.

    Science.gov (United States)

    Bokarev, Sergey I; Dantz, Marcus; Suljoti, Edlira; Kühn, Oliver; Aziz, Emad F

    2013-08-23

    Nonradiative decay channels in the L-edge fluorescence yield spectra from transition-metal-aqueous solutions give rise to spectral distortions with respect to x-ray transmission spectra. Their origin is unraveled here using partial and inverse partial fluorescence yields on the microjet combined with multireference ab initio electronic structure calculations. Comparing Fe2+, Fe3+, and Co2+ systems we demonstrate and quantify unequivocally the state-dependent electron delocalization within the manifold of d orbitals as one origin of this observation.

  8. Temperature dependence of the electronic structure of Sr14Cu24O41 studied by resonant inelastic X-ray scattering

    International Nuclear Information System (INIS)

    Yoshida, M.; Ishii, K.; Ikeuchi, K.; Jarrige, I.; Murakami, Y.; Mizuki, J.; Tsutsui, K.; Tohyama, T.; Maekawa, S.; Kudo, K.; Koike, Y.; Endoh, Y.

    2010-01-01

    We report a resonant inelastic X-ray scattering (RIXS) study of charge excitations in the two-leg ladder Sr 14 Cu 24 O 41 . RIXS spectra at 1-5 eV are found to be dependent on temperature. An intraband excitation of the ladder, which appears as a continuum intensity below the Mott gap, decreases in intensity with temperature. Because the intraband excitation is related to the dynamics of doped holes in the ladder, its decrease of the intraband excitation is attributed to the reduction of the mobile holes in the ladder at low temperature.

  9. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  10. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  11. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  12. Lethal and teratogenic effects after exposure to X-rays at various times of early murine gestation

    International Nuclear Information System (INIS)

    Mueller, W.U.S.; Streffer, C.

    1990-01-01

    Various well-defined stages during completion of the second meiotic division and early organogenesis of mouse embryos were X-irradiated with doses of 1-4 Gy (100-400 rad). The major risk was prenatal mortality with radiation sensitivity changing markedly with dependence on the developmental stage irradiated; in the case of day 1 even within hours. The surviving fetuses did show a significantly enhanced frequency of malformations on day 19 of gestation (mostly gastroschisis and some exencephalies). This was true for all stages between days 1 and 8; only sensitivity again changed considerably. The radiation doses used in this study are markedly higher than doses that can be expected from radiation diagnostics, but exposure is in a range comparable to doses that can occur in radiation therapy (e.g., Morbus Hodgkin)

  13. The upper limits of the SNR in radiography and CT with polyenergetic x-rays

    International Nuclear Information System (INIS)

    Shikhaliev, Polad M

    2010-01-01

    The aim of the study is to determine the upper limits of the signal-to-noise ratio (SNR) in radiography and computed tomography (CT) with polyenergetic x-ray sources. In x-ray imaging, monoenergetic x-rays provide a higher SNR compared to polyenergetic x-rays. However, the SNR in polyenergetic x-ray imaging can be increased when a photon-counting detector is used and x-rays are optimally weighted according to their energies. For a particular contrast/background combination and at a fixed x-ray entrance skin exposure, the SNR in energy-weighting x-ray imaging depends on tube voltage and can be maximized by selecting the optimal tube voltage. The SNR in energy-weighted x-ray images acquired at this optimal tube voltage is the highest SNR that can be achieved with polyenergetic x-ray sources. The optimal tube voltages and the highest SNR were calculated and compared to the SNR of monoenergetic x-ray imaging. Monoenergetic, energy-weighting polyenergetic and energy-integrating polyenergetic x-ray imagings were simulated at a fixed entrance skin exposure of 20 mR. The tube voltages varied in the range of 30-140 kVp with 10 kV steps. Contrast elements of CaCO 3 , iodine, adipose and tumor with thicknesses of 280 mg cm -2 , 15 mg cm -2 , 1 g cm -2 and 1 g cm -2 , respectively, inserted in a soft tissue background with 10 cm and 20 cm thicknesses, were used. The energy weighting also improves the contrast-to-noise ratio (CNR) in CT when monoenergetic CT projections are optimally weighted prior to CT reconstruction (projection-based weighting). Alternatively, monoenergetic CT images are reconstructed, optimally weighted and composed to yield a final CT image (image-based weighting). Both projection-based and image-based weighting methods improve the CNR in CT. An analytical approach was used to determine which of these two weighting methods provides the upper limit of the CNR in CT. The energy-weighting method was generalized and expanded as a weighting method applicable in

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  16. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  18. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  20. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  1. Strain-dependent evolution of garnets in a high pressure ductile shear zone using Synchroton x-ray microtomography

    Science.gov (United States)

    Macente, Alice; Fusseis, Florian; Menegon, Luca; John, Timm

    2016-04-01

    Synkinematic reaction microfabrics carry important information on the kinetics, timing and rheology of tectonometamorphic processes. Despite being routinely interpreted in metamorphic and structural studies, reaction and deformation microfabrics are usually described in two dimensions. We applied Synchrotron-based x-ray microtomography to document the evolution of a pristine olivine gabbro into a deformed omphacite-garnet eclogite in 3D. In the investigated samples, which cover a strain gradient into a shear zone from the Western Gneiss Region (Norway) previously described by John et al., (2009), we focused on the spatial transformation of garnet coronas into elongated clusters of garnets. Our microtomographic data allowed us to quantify changes to the garnet volume, their shapes and their spatial arrangement. We combined microtomographic observations with light microscope- and backscatter electron images as well as electron microprobe- (EMPA) and electron backscatter diffraction (EBSD) analyses to correlate mineral composition and orientation data with the x-ray absorption signal of the same mineral grains. This allowed us to extrapolate our interpretation of the metamorphic microfabric evolution to the third dimension, effectively yielding a 4-dimensional dataset. We found that: - The x-ray absorption contrast between individual mineral phases in our microtomographic data is sufficient to allow the same petrographic observations than in light- and electron microscopy, but extended to 3D. - Amongst the major constituents of the synkinematic reactions, garnet is the only phase that can be segmented confidently from the microtomographic data. - With increasing deformation, the garnet volume increases from about 9% to 25%. - Garnet coronas in the gabbros never completely encapsulate olivine grains. This may indicate that the reaction progressed preferentially in some directions, but also leaves pathways for element transport to and from the olivines that are

  2. Use of lead aprons - further considerations of estimation of doses and conditions of acute exposures of TLD badge in diagnostic x-ray institutions

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.

    2003-01-01

    In the recent study the authors reported that the exposure conditions of the use of the TLD badge, whether worn under or over the lead apron could be estimated from the readout of the TLD badge used in X-ray diagnostic departments. The effectiveness of lead aprons procured from different suppliers having the same value of quoted nominal lead equivalence was found to vary severely and this indicated some limitation in the applicability of the method of evaluation of exposure conditions of the badge. The transmission factors for the lead aprons varied up to a factor of 15 for the same value of quoted nominal lead equivalence procured from three different suppliers. This is of serious consequences in radiation protection and attracts attention for quality control. An error in the estimation of the exposure conditions of the TLD badge could lead to an underestimation of doses up to 4 times using the prevalent method. The estimation of the actual doses of radiation workers in the cases of over-exposures for the situations of the use of the TLD badge over the lead apron showed that the variation in the quality of lead aprons could be wrong in the range from 1.6 to 25 times even if the kVp of the machine is exactly known. Therefore, attempt should not be made to estimate the actual doses under lead apron from the readout of the TLD badge worn over the apron, as the real values of the transmission factors of the aprons and kVp of the X-ray machine may not be available. (author)

  3. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... also be useful to help diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  6. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... June is Men's Health Month Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  14. Study of optimal X-ray exposure conditions in consideration of bone mineral density. Relation between bone mineral density and image contrast

    International Nuclear Information System (INIS)

    Kondo, Yuji

    2003-01-01

    Bone mineral density (BMD) increases through infancy and adolescence, reaching a maximum at 20-30 years of age. Thereafter, BMD gradually decreases with age in both sexes. The image contrast of radiographs of bones varies with the change in BMD owing to the changes in the X-ray absorption of bone. The image contrast of bone generally is higher in the young adult than in the older adult. To examine the relation between BMD and image visibility, we carried out the following experiments. We measured the image contrast of radiographs of a lumbar vertebra phantom in which BMD was equivalent to the average BMD for each developmental period. We examined image visibility at various levels of imaging contrast using the Howlett chart. The results indicated that differences in BMD affect the image contrast of radiographs, and, consequently, image visibility. It was also found that image visibility in the young adult was higher than that in the older adult. The findings showed that, in digital radiography of young adults with high BMD, X-ray exposure can be decreased according the ratio of improvement in image visibility. (author)

  15. Analgesia induced by repeated exposure to low dose X-rays in mice, and involvement of the accessory olfactory system in modulation of the radiation effects

    International Nuclear Information System (INIS)

    Miyachi, Yukihisa; Yamada, Takeshi

    1997-01-01

    The effects of low-dose X-rays on mouse nociceptive behavior were examined using a formalin injected test which rated the amount of time the animals spent licking the injected hind-paw. Male ICR White Swiss mice showed a marked suppression of licking behavior after repeated low-dose X-irradiation (5 cGy/day, 6 consecutive days). The most profound effect was observed on the day 30 after irradiation. The decline of licking behavior, however, was not observed at all following olfactory bulbectomy or vomeronasal tract cut. The analgesic effects could be observed in writhing animals administered acetic-acid intraperitoneally. Moreover, analgesia was totally blocked by the administration of N-nitro-L-arginine, a nitric oxide synthase inhibitor, to accessory olfactory bulbs prior to the exposure. The present results indicate that the olfactory system plays an important role in modulation of radiation-induced analgesia, and a possible involvement of nitric oxide in the formation of recognition memory subjected to repeated X-rays. Relatively higher doses (5 cGy x 9 days, 5 cGy x 12 days), however, did not induce such effects, namely, the decline of nociceptive response was limited to the animals irradiated with the smaller dose. (author)

  16. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  17. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  18. The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors

    International Nuclear Information System (INIS)

    Hunter, David M.; Belev, Gueorgi; DeCrescenzo, Giovanni; Kasap, Safa O.; Mainprize, James G.; Rowlands, J. A.; Smith, Charles; Tuemer, Tuemay; Verpakhovski, Vladimir; Yin Shi; Yaffe, Martin J.

    2007-01-01

    Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 μm and the blocking layer thicknesses varied from 1 to 51 μm. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was ∼200 μm. As expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk

  19. Age-dependent decline in rejoining of X-ray-induced DNA double-strand breaks in normal human lymphocytes

    International Nuclear Information System (INIS)

    Mayer, P.J.; Lange, C.S.; Bradley, M.O.; Nichols, W.W.

    1989-01-01

    Unstimulated human peripheral bloodlymphocytes (HPBL), separated by density centrifugation from anticoagulated whole blood, were X-irradiated on ice and incubated in medium at 37 0 C for repair times of 15, 30 and 120 min. Blood donors were 18 normotensive, non-smoking Caucasians aged 23-78, free from overt pathology and not taking any medications. Neutral filter elution was used to assay DNA double-strand break (DSB) induction and completeness of DSB rejoining. After 30 or 120 min repair incubation, the percentage of DSBs rejoined by cells from oder donors was less than half the percentage of DSBs rejoined by cells from younger donors. When data from the 3 age groups were pooled, the age-related decline in percent DSBs rejoined was significant for repair times 30 min and 120 min but not for 15 min. These age-related declines were observed even though DNA from older donors sustained fewer strand breaks as demonstrated by the negative correlation between donor age and DSB induction. These results suggest that the efficacy of X-ray-induced DSB repair diminishes with in vivo age in unstimulated HPBL. (author). 38 refs.; 2 figs.; 1 tab

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  5. In situ SERS and X-ray photoelectron spectroscopy studies on the pH-dependant adsorption of anthraquinone-2-carboxylic acid on silver electrode

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dan, E-mail: dany@sit.edu.cn [School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418 (China); Jia, Shaojie [School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418 (China); Fodjo, Essy Kouadio [Laboratory of Physical Chemistry, University Felix Houphouet Boigny, 22 BP 582, Abidjan 22, Cote d’Ivoire (Cote d' Ivoire); Xu, Hu [School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418 (China); Wang, Yuhong, E-mail: yuhong_wang502@sit.edu.cn [School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418 (China); Deng, Wei [School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418 (China)

    2016-03-30

    Graphical abstract: The orientation of anthraquinone-2-carboxylic acid (AQ-2-COOH) has been investigated by in situ surface-enhanced Raman scattering (in situ SERS) spectroelectrochemistry and angle-resolved X-ray photoelectron spectroscopy (AR-XPS) on silver surface. - Highlights: • The adsorption behavior of anthraquinone-2-carboxylic acid (AQ-2-COOH) on Ag electrode is influenced by the pH. • The pH-dependant adsorption of AQ-2-COOH has been confirmed by in situ surface-enhanced Raman scattering (in situ SERS) spectroelectrochemistry and angle-resolved X-ray photoelectron spectroscopy (AR-XPS). • The results can provide insights into electron transfer reactions of AQ-2-COOH in biological systems. - Abstract: In this study, in situ surface-enhanced Raman scattering (SERS) spectroelectrochemistry and angle-resolved X-ray photoelectron spectroscopy (AR-XPS) are used to investigate the redox reaction and adsorption behavior of anthraquinone-2-carboxylic acid (AQ-2-COOH) on an Ag electrode at different pH values. The obtained results indicate that AQ-2-COOH is adsorbed tilted on the Ag electrode through O-atom of ring carbonyl in a potential range from −0.3 to −0.5 V vs. SCE, but the orientation turns to more tilted orientation with both O-atom of the ring carbonyl and carboxylate group in positive potential region for pH 6.0 and 7.4. However, at pH 10.0, the orientation adopts tilted conformation constantly on the Ag electrode with both O-atom of the anthraquinone ring and carboxylate group in the potential range from −0.3 to −0.5 V vs. SCE or at positive potentials. Moreover, the adsorption behavior of AQ-2-COOH has been further confirmed by AR-XPS on the Ag surface. Proposed reasons for the observed changes in orientation are presented.

  6. Expression, purification, crystallization and preliminary X-ray analysis of an NADP-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, Paul R.; Evans, Daniel; Greenwood, Jacqueline A.; Moody, Peter C. E., E-mail: pcem1@leicester.ac.uk [Henry Wellcome Laboratories for Structural Biology, Department of Biochemistry, University of Leicester, Leicester LE1 9HN (United Kingdom)

    2008-08-01

    Glyceraldehyde-3-phosphate dehydrogenase A has been cloned, expressed and purified. Apoprotein crystals have been grown which diffracted to 1.75 Å resolution and belonged to space group P2{sub 1}; holo crystals were grown in the presence of NADP, diffracted to 2.6 Å resolution and belonged to space group P3{sub 2}. The classical glycolytic pathway contains an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase, with NADP-dependent forms reserved for photosynthetic organisms and archaea. Here, the cloning, expression, purification, crystallization and preliminary X-ray analysis of an NADP-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori is reported; crystals of the protein were grown both in the presence and the absence of NADP.

  7. Expression, purification, crystallization and preliminary X-ray analysis of an NADP-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori

    International Nuclear Information System (INIS)

    Elliott, Paul R.; Evans, Daniel; Greenwood, Jacqueline A.; Moody, Peter C. E.

    2008-01-01

    Glyceraldehyde-3-phosphate dehydrogenase A has been cloned, expressed and purified. Apoprotein crystals have been grown which diffracted to 1.75 Å resolution and belonged to space group P2 1 ; holo crystals were grown in the presence of NADP, diffracted to 2.6 Å resolution and belonged to space group P3 2 . The classical glycolytic pathway contains an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase, with NADP-dependent forms reserved for photosynthetic organisms and archaea. Here, the cloning, expression, purification, crystallization and preliminary X-ray analysis of an NADP-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori is reported; crystals of the protein were grown both in the presence and the absence of NADP

  8. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  9. Effect of combined treatments of pepleomycin with x-ray in cultured cells of a mouse squamous cell carcinoma

    International Nuclear Information System (INIS)

    Yokota, Masahiko; Wakamatsu, Yoshiko; Sairenji, Eiko; Ohara, Hirosi.

    1986-01-01

    Cultured SQ-1979 cells of C3H mouse squamous cell carcinomas in logarithmic growth phase were treated with either pepleomycin (PEP) or bleomycin (BLM), alone or in combination with X-rays. The lethal effect of PEP on the SQ cells was greater than that of BLM. The survival curves of the cells were biphasic at concentrations examined (5 to 60 μg/ml) of PEP. The survival depended on the concentration and treatment time up to 3 hr. The cells treated with BLM showed biphasic survival curves also. Regarding combined effects of either PEP or BLM and X-rays, there was no significant difference in the survival curves between the group with X-rays and the group with X-rays and drug. When a drug was given 4 hr after exposure to X-rays rather than before that, synergistic action of the drug and X-rays was attained. This was marked for PEP. (Namekawa, K.)

  10. Unoccupied density of states of La2–xSrxNiO4+δ studied by polarization-dependent x-ray-absorption spectroscopy and bremsstrahlung isochromat spectroscopy

    NARCIS (Netherlands)

    Kuiper, P.; Elp, J. van; Sawatzky, G.A.; Fujimori, A.; Hosoya, S.; Leeuw, D.M. de

    1991-01-01

    Oxygen 1s x-ray-absorption measurements of La2–xSrxNiO4+δ (0≤x≤1.15) are presented, together with O 1s polarization-dependent x-ray absorption on single-crystal La1.85Sr0.15NiO4. It is concluded that the charge-compensating holes have mainly oxygen 2p character. The Ni 3d9 final states reached

  11. Expression, purification, crystallization and preliminary X-ray diffraction analysis of the TonB-dependent haem outer membrane transporter ShuA from Shigella dysenteriae

    International Nuclear Information System (INIS)

    Brillet, Karl; Meksem, Ahmed; Thompson, Andrew; Cobessi, David

    2009-01-01

    ShuA from S. dysenteriae was crystallized in several crystallization conditions containing detergents. Adding heavy atoms during crystallization strongly improved the crystal quality and the resolution limits. Diffraction data were collected at an energy remote from the Pb M absorption edges. As part of efforts towards understanding the crystallization of membrane proteins and membrane transport across the outer membrane of Gram-negative bacteria, the TonB-dependent haem outer membrane transporter ShuA of Shigella dysenteriae bound to heavy atoms was crystallized in several crystallization conditions using detergents. The insertion of a His 6 tag into an extracellular loop of ShuA, instead of downstream of the Escherichia coli peptide signal, allowed efficient targeting to the outer membrane and the rapid preparation of crystallizable protein. Crystals diffracting X-rays beyond 3.5 Å resolution were obtained by co-crystallizing ShuA with useful heavy atoms for phasing (Eu, Tb, Pb) by the MAD method at the synchrotron, and the SAD or SIRAS method at the Cu wavelength. The authors collected X-ray diffraction data at 2.3 Å resolution using one crystal of ShuA-Pb, and at 3.2 Å resolution at an energy remote from the Pb M absorption edges for phasing on PROXIMA-1 at SOLEIL

  12. Simulation of Near-Edge X-ray Absorption Fine Structure with Time-Dependent Equation-of-Motion Coupled-Cluster Theory.

    Science.gov (United States)

    Nascimento, Daniel R; DePrince, A Eugene

    2017-07-06

    An explicitly time-dependent (TD) approach to equation-of-motion (EOM) coupled-cluster theory with single and double excitations (CCSD) is implemented for simulating near-edge X-ray absorption fine structure in molecular systems. The TD-EOM-CCSD absorption line shape function is given by the Fourier transform of the CCSD dipole autocorrelation function. We represent this transform by its Padé approximant, which provides converged spectra in much shorter simulation times than are required by the Fourier form. The result is a powerful framework for the blackbox simulation of broadband absorption spectra. K-edge X-ray absorption spectra for carbon, nitrogen, and oxygen in several small molecules are obtained from the real part of the absorption line shape function and are compared with experiment. The computed and experimentally obtained spectra are in good agreement; the mean unsigned error in the predicted peak positions is only 1.2 eV. We also explore the spectral signatures of protonation in these molecules.

  13. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  14. Measuring scatter radiation in diagnostic x rays for radiation protection purposes

    International Nuclear Information System (INIS)

    Panayiotakis, George; Vlachos, Ioannis; Delis, Harry; Tsantilas, Xenophon; Kalyvas, Nektarios; Kandarakis, Ioannis

    2015-01-01

    During the last decades, radiation protection and dosimetry in medical X-ray imaging practice has been extensively studied. The purpose of this study was to measure secondary radiation in a conventional radiographic room, in terms of ambient dose rate equivalent H*(10) and its dependence on the radiographic exposure parameters such as X-ray tube voltage, tube current and distance. With some exceptions, the results indicated that the scattered radiation was uniform in the space around the water cylindrical phantom. The results also showed that the tube voltage and filtration affect the dose rate due to the scatter radiation. Finally, the scattered X-ray energy distribution was experimentally calculated. (authors)

  15. Detection of Reaction Intermediates in Mg2+-Dependent DNA Synthesis and RNA Degradation by Time-Resolved X-Ray Crystallography.

    Science.gov (United States)

    Samara, Nadine L; Gao, Yang; Wu, Jinjun; Yang, Wei

    2017-01-01

    Structures of enzyme-substrate/product complexes have been studied for over four decades but have been limited to either before or after a chemical reaction. Recently using in crystallo catalysis combined with X-ray diffraction, we have discovered that many enzymatic reactions in nucleic acid metabolism require additional metal ion cofactors that are not present in the substrate or product state. By controlling metal ions essential for catalysis, the in crystallo approach has revealed unprecedented details of reaction intermediates. Here we present protocols used for successful studies of Mg 2+ -dependent DNA polymerases and ribonucleases that are applicable to analyses of a variety of metal ion-dependent reactions. © 2017 Elsevier Inc. All rights reserved.

  16. Energy and CKT dependence of proton induced L subshell X-ray intensity ratios in elements 57≤Z≤92

    International Nuclear Information System (INIS)

    Thakkar, Rohit; Sharma, Babita; Allawadhi, K.L.

    2006-01-01

    The dependence of L subshell X-ray intensity ratios on incident proton energy and the CK transitions has been investigated in elements 57≤Z≤92. The intensity ratio I(L α )/I(L l ) neither shows variation with energy nor any dependence on the CK transitions. In general, the ratios I(L α )/I(L β ) and I(L α )/I(L γ ), first increase with incident proton energy, attain a maximum value, then start decreasing and attain an almost constant value after a particular energy (ranging from about 4.6 MeV for La to 5.8 MeV for U). A comparison has been made among the intensity ratios evaluated using three different sets of parameters. A maximum difference of about 18% has been observed among the different values

  17. Destroying the photoelectret in Bi12SiO20 by X-ray irradiation

    International Nuclear Information System (INIS)

    Vavrek, A. F.; Khristova, K. K.

    1987-01-01

    The destroying of the classical photoelectret state (PES) in bismuth silicon oxide (BSO) monocrystals during X-ray irradiation is investigated and the reciprocity law (RL) is examined. The sample is irradiated by nonfiltered X-rays with continuous spectrum and maximum energy of the photons 70 keV. The polaryzing voltage used is 85 V. The dependence of the destroyed PE charge on the time of X-ray irradiation of the sample with equal X-ray exposure in each point shows that the exposure rates higher than a certain 'critical' value cause a larger destroyed charge that is RL during X-ray irradiation. The 'critical' value is about 3x10 -5 A/kg. The dependence of the destroyed photoelectric (PE) charge on the irradiation time generally shows that the destroyed PE charge increases with the increase of the X-ray exposure. After some time the distruction of the charge is terminated and the sample seems to lose its X-ray sensitivity although a considerable PE charge (30-40% of the initial one) remains in it. At higher exposure rates (above the critical one for the RL) the maxmimum destroyed charge is smaller. According to the dependencies of the linear coefficients of X-ray attenuation in the investigated energy range the photoelectric absorption is dominating. The radiation is absorbed only in the near-surface region. Part of the sample remains nonexited and the PE charge which has been initially barrier distributed is destroyed as a result of the redistribution of the charges in the excitation region only. At sufficiently long irradiation time this redistribution is terminated, notwithstanding the fact that out of the excitation region the sample still remains polarized. The maximum destroyed PE charge during nonhomogeneous excitation under nonquasi-stationary conditions is smaller at higher exposure rates because of the lower values of the diffusion and drift length

  18. Degradation of organophosphorus compounds by X-ray irradiation

    International Nuclear Information System (INIS)

    Trebse, P.; Arcon, I.

    2002-01-01

    Complete text of publication follows. Our research presented in this contribution aims to elucidate the degradation mechanisms of organophosphate pesticides as organic pollutants by X-ray irradiation. Diazinon, one of the most widely used pesticides in Slovenia, has been chosen as a model compound for the study of radiation induced degradation of organophosphorus pesticides. Recent studies have shown that the degradation of the pesticide at normal conditions (room temperature, exposure to daylight) is strongly enhanced when the pesticide is exposed to UV light (Hg lamp, λ=254 nm, XeCl excimer laser, λ=308 nm). In our study we irradiated the pesticide in aqueous media with a white x-ray beam from a conventional x-ray source. Mo X-ray tube operating at the high voltage of 55 kV and a current of 45 mA was used. The flux of the continuous X-ray beam was stabilized within 1%. Saturated water solution of the pesticide (volume: 4mL, conc. of 40 mg L -1 ) was inserted in 1 cm long lucite cell with 1 mm thick lucite windows. The whole volume of the solution in the cell was exposed to the unfiltered X-ray beam. The dose rate on the sample was about 1 mGy/s. Different irradiation times between 30 min to 120 min were chosen to study the dependence of the pesticide decomposition with the absorbed dose. Solid phase extraction was employed for sample extraction from the solution, and gas chromatography was used for the identification and quantification of the compounds. The results show that the concentration of the pesticide in the solution decreases exponentially with the exposure time, i.e. with the absorbed dose. At irradiation conditions described above, the time constant of the exponential decrease was 74 min

  19. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  20. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  1. Some complementary results to the granularity of industrial X-ray films

    International Nuclear Information System (INIS)

    Stade, J.

    1987-01-01

    The granularity of industrial x-ray films was examined by measurements of the Wiener spectra. The dependence of the Weiner spectra on film density, type of film, type of developer, energy of the exposing x-radiation, and light exposure, was also investigated. The results revealed that the Weiner spectrum or related quantities were suitable as a tool for measuring the influence of different radiographic parameters on the x-ray film, as well as to characterize its properties. (UK)

  2. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel

  3. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel.

  4. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  5. X-ray astronomy

    International Nuclear Information System (INIS)

    Narayanan, M.S.

    1976-01-01

    The deployment of detectors outside the deleterious effects of the atmosphere by sending them in space vehicles, has been explained. This has thrown open the entire spectrum of the electromagnetic and particle radiation to direct observations, thus enlarging the vistas of the field of astronomy and astrophysics. The discovery of strong emitters of X-rays such as SCO X-1, NorX-2, transient sources such as Cen X-2, Cen X-4, Cen X-1, Supernova remnants Tan X-1, etc., are reported. The background of the X-ray spectrum as measured during two rocket flights over Thumba, India is presented. (K.B.)

  6. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  7. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  8. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  9. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  10. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  11. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  12. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  13. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  14. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  15. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  16. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  17. The application of synchrotron radiation to X-ray lithography

    International Nuclear Information System (INIS)

    Spiller, E.; Eastman, D.E.; Feder, R.; Grobman, W.D.; Gudat, W.; Topalian, J.

    1976-06-01

    Synchrotron radiation from the German electron synchrotron DESY in Hamburg has been used for X-ray lithograpgy. Replications of different master patterns (for magnetic bubble devices, fresnel zone plates, etc.) were made using various wavelengths and exposures. High quality lines down to 500 A wide have been reproduced using very soft X-rays. The sensitivities of X-ray resists have been evaluated over a wide range of exposures. Various critical factors (heating, radiation damage, etc.) involved with X-ray lithography using synchrotron radiation have been studied. General considerations of storage ring sources designed as radiation sources for X-ray lithography are discussed, together with a comparison with X-ray tube sources. The general conclusion is that X-ray lithography using synchrotron radiation offers considerable promise as a process for forming high quality sub-micron images with exposure times as short as a few seconds. (orig.) [de

  18. THE MEGASECOND CHANDRA X-RAY VISIONARY PROJECT OBSERVATION OF NGC 3115. III. LUMINOSITY FUNCTIONS OF LMXBS AND DEPENDENCE ON STELLAR ENVIRONMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Dacheng; Irwin, Jimmy A. [Department of Physics and Astronomy, University of Alabama, Box 870324, Tuscaloosa, AL 35487 (United States); Wong, Ka-Wah [Eureka Scientific, Inc., 2452 Delmer Street Suite 100, Oakland, CA 94602-3017 (United States); Jennings, Zachary G.; Romanowsky, Aaron J.; Brodie, Jean P. [University of California Observatories, Santa Cruz, CA 95064 (United States); Homan, Jeroen; Remillard, Ronald A. [MIT Kavli Institute for Astrophysics and Space Research, MIT, 70 Vassar Street, Cambridge, MA 02139-4307 (United States); Strader, Jay [Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan, MI 48824 (United States); Sivakoff, Gregory R., E-mail: dacheng.lin@unh.edu [Department of Physics, University of Alberta, Edmonton, Alberta, T6G 2E1 (Canada)

    2015-07-20

    We studied the X-ray luminosity function (XLF) of low-mass X-ray binaries (LMXBs) in the nearby lenticular galaxy NGC 3115, using the Megasecond Chandra X-ray Visionary Project Observation. With a total exposure time of ∼1.1 Ms, we constructed the XLF down to a limiting luminosity of ∼10{sup 36} erg s{sup −1}, which is much deeper than that typically reached for other early-type galaxies. We found significant flattening of the overall LMXB XLF from dN/dL ∝ L{sup −2.2±0.4} above 5.5 × 10{sup 37} erg s{sup −1} to dN/dL ∝ L{sup −1.0±0.1} below it, although we could not rule out a fit with a higher break at ∼1.6 × 10{sup 38} erg s{sup −1}. We also found evidence that the XLF of LMXBs in globular clusters (GCs) is overall flatter than that of field LMXBs. Thus, our results for this galaxy do not support the idea that all LMXBs are formed in GCs. The XLF of field LMXBs seems to show spatial variation, with the XLF in the inner region of the galaxy being flatter than that in the outer region, probably due to contamination of LMXBs from undetected and/or disrupted GCs in the inner region. The XLF in the outer region is probably the XLF of primordial field LMXBs, exhibiting dN/dL ∝ L{sup −1.2±0.1} up to a break close to the Eddington limit of neutron star LMXBs (∼1.7 × 10{sup 38} erg s{sup −1}). The break of the GC LMXB XLF is lower, at ∼1.1 × 10{sup 37} erg s{sup −1}. We also confirm previous findings that the metal-rich/red GCs are more likely to host LMXBs than the metal-poor/blue GCs, which is more significant for more luminous LMXBs, and that more massive GCs are more likely to host LMXBs.

  19. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  20. Response of TLD badge for the estimation of exposure conditions in diagnostic x-ray departments - use of lead aprons

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.; Bakshi, A.K.

    2002-01-01

    The present study was undertaken to ascertain the conditions of exposure of the TLD badge and to evaluate the inaccuracy involved in the estimation of dose received by the worker using an averaged lead apron transmission factor for the use of the badge above lead apron

  1. Expression, purification, crystallization and preliminary X-ray analysis of an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, Paul R.; Mohammad, Shabaz; Melrose, Helen J.; Moody, Peter C. E., E-mail: pcem1@leicester.ac.uk [Henry Wellcome Laboratories for Structural Biology, University of Leicester, Leicester LE1 9HN (United Kingdom)

    2008-08-01

    Glyceraldehyde-3-phosphate dehydrogenase B from H. pylori has been cloned, expressed, purified and crystallized in the presence of NAD. Crystals of GAPDHB diffracted to 2.8 Å resolution and belonged to space group P6{sub 5}22, with unit-cell parameters a = b = 166.1, c = 253.1 Å. Helicobacter pylori is a dangerous human pathogen that resides in the upper gastrointestinal tract. Little is known about its metabolism and with the onset of antibiotic resistance new treatments are required. In this study, the expression, purification, crystallization and preliminary X-ray diffraction of an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase from H. pylori are reported.

  2. Concentration and temperature dependence of short-range order in Ni-Ta solid solution using X-ray diffraction method

    International Nuclear Information System (INIS)

    Khwaja, F.A.; Alam, A.

    1980-09-01

    Diffuse X-ray scattering investigations about the existence of short-range order (SRO) have been carried out in the Ni-Ta system for different concentrations and annealing temperatures. It is observed that the values of the SRO parameters for the first co-ordination shell have anomalously large negative values for all the samples studied. These values of the α 1 depend upon the annealing temperatures and the concentration of Ta atoms in the Ni-Ta system. The results of the theoretical predictions of the ordering potential obtained using the formulae of the electronic theory of SRO, confirm the existence of very strong attractive correlation between the atoms of the different species in this system. (author)

  3. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  4. Chest X-Ray

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  5. X-ray sources

    International Nuclear Information System (INIS)

    Bonse, U.

    1979-11-01

    The author describes several possibilities for the production of X-radiation. Especially he discusses the use of bremsstrahlung at electron impact on solid targets and the synchrotron radiation. He presents some equations for the calculation of X-ray intensities. Especially the X-radiation from the DORIS storage ring is discussed. (HSI)

  6. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... change into a gown. You may have some concerns about chest x-rays. However, it’s important to ... You Sponsored by About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  8. The effect of embryonic and fetal exposure to x-ray, microwaves, and ultrasound: Counseling the pregnant and nonpregnant patient about these risks

    International Nuclear Information System (INIS)

    Brent, R.L.

    1989-01-01

    The term radiation evokes emotional responses both from lay persons and from professionals. Many spokespersons are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic-imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue; however, at present ultrasound not only improves obstetric care, but also reduces the necessity of diagnostic x-ray procedures. In the field of ionizing radiation, we have a better comprehension of the biologic effects and the quantitative maximum risks than for any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, IUGR, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation, Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. It is obvious that the risks of 1-rad (.10Gy) or 5-rad (.05Gy) acute exposure are far below the spontaneous risks of the developing embryo because 15% of human embryos abort, 2.7% to 3.0% of human embryos have major malformations, 4% have intrauterine growth retardation, and 8% to 10% have early- or late-stage onset genetic disease. 92 references

  9. Topology and temperature dependence of the diffuse X-ray scattering in Na0.5Bi0.5TiO3 ferroelectric single crystals.

    Science.gov (United States)

    Gorfman, Semën; Keeble, Dean S; Bombardi, Alessandro; Thomas, Pam A

    2015-10-01

    The results of high-resolution measurements of the diffuse X-ray scattering produced by a perovskite-based Na 0.5 Bi 0.5 TiO 3 ferroelectric single crystal between 40 and 620 K are reported. The study was designed as an attempt to resolve numerous controversies regarding the average structure of Na 0.5 Bi 0.5 TiO 3 , such as the mechanism of the phase transitions between the tetragonal, P 4 bm , and rhombohedral | monoclinic, R 3 c  |  Cc , space groups and the correlation between structural changes and macroscopic physical properties. The starting point was to search for any transformations of structural disorder in the temperature range of thermal depoling (420-480 K), where the average structure is known to remain unchanged. The intensity distribution around the {032} pseudocubic reflection was collected using a PILATUS 100K detector at the I16 beamline of the Diamond Light Source (UK). The data revealed previously unknown features of the diffuse scattering, including a system of dual asymmetric L-shaped diffuse scattering streaks. The topology, temperature dependence, and relationship between Bragg and diffuse intensities suggest the presence of complex microstructure in the low-temperature R 3 c  |  Cc phase. This microstructure may be formed by the persistence of the higher-temperature P 4 bm phase, built into a lower-temperature R 3 c  |  Cc matrix, accompanied by the related long-range strain fields. Finally, it is shown that a correlation between the temperature dependence of the X-ray scattering features and the temperature regime of thermal depoling is present.

  10. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  11. Risk estimates for meningiomas and other late effects after diagnostic X-ray exposure of the skull

    International Nuclear Information System (INIS)

    Pflugbeil, S.; Pflugbeil, C.; Schmitz-Feuerhake, I.

    2011-01-01

    This study aims to investigate the contribution of diagnostic exposures to the rising rates of brain tumours and other neoplasms which are observed in several industrial nations. Included are benign tumours in the head and neck region and cataracts which are neglected in usual risk estimates by international and national radiation protection committees. Dose-effect relationships for tumours of the brain, skin, thyroid and other sites of the head region, leukaemia and cataracts are taken from the literature. Risk estimates are derived for paediatric head computed tomographies (CTs) as well as for brain tumours in adults. On the basis of estimates for Germany about the number of head scans, the annual rate of radiation-induced diseases is calculated. About 1000 annual paediatric CT investigations of the skull will lead to about three excess neoplasms in the head region, i.e. the probability of an induced late effect must be suspected in the range of some thousands. Additionally, a relevant increase of cataracts must be considered. The radiation-induced occurrence of meningiomas and other brain tumours most probably contributes to the continuously increasing incidence of these diseases which is observed in several industrial nations, as well as the exposure of the bone marrow by CT to the increase of childhood leukaemia. (authors)

  12. Assessment of genetic risk of exposure resulted from X-ray examination of women of the reproductive age

    International Nuclear Information System (INIS)

    Strel'nikova, N.K.

    1989-01-01

    On the basis of the available data an evaluation of genetic radiation risk during roentgenologic examination of women of the reproductive age is presented. It is demonstrated that the degree of genetic risk depends on woman's age at the moment of the roentgenologic examination and the amount of the gonadal dose. Identification of the high-risk exposed populations has been substantiated

  13. LCLS X-Ray FEL Output Performance in the Presence of Highly Time-Dependent Undulator Wakefields

    International Nuclear Information System (INIS)

    Bane, Karl L.F.; Emma, Paul; Huang, Heinz-Dieter Nuhn; Stupakov, Gennady; Fawley, William M.; Reiche, Sven

    2005-01-01

    Energy loss due to wakefields within a long undulator, if not compensated by an appropriate tapering of the magnetic field strength, can degrade the FEL process by detuning the resonant FEL frequency. The wakefields arise from the vacuum chamber wall resistivity, its surface roughness, and abrupt changes in its aperture. For LCLS parameters, the resistive-wall component is the most critical and depends upon the chamber material (e.g., Cu) and its radius. Of recent interest[1] is the so-called ''AC'' component of the resistive-wall wake which can lead to strong variations on very short timescales (e.g., ∼ 20 0fs). To study the expected performance of the LCLS in the presence of these wakefields, we have made an extensive series of start-to-end SASE simulations with tracking codes PARMELA and ELEGANT, and time-dependent FEL simulation codes GENESIS1.3 and GINGER. We discuss the impact of the wakefield losses upon output energy, spectral bandwidth, and temporal envelope of the output FEL pulse, as well as the benefits of a partial compensation of the time-dependent wake losses obtained with a slight z-dependent taper in the undulator field. We compare the taper results to those predicted analytically[2

  14. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  15. X-ray diagnosis of rib chondrosarcoma

    International Nuclear Information System (INIS)

    Smakova, M.S.

    1982-01-01

    A study was made on X-ray images of 24 patients, suffering from rib chondrosarcoma with relapses. X-ray symptoms of rib chondrosarcoma, depending on process localization were improved. Chondrosarcoma of rib cartilage is characterized by soft-tissue component with calcareous inclusions or without them. Chondrosarcoma of rib bone is characterized by destruction and soft-tissue component. Chondrosarcoma relapses were localized in soft tissues

  16. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  17. Diagnostic x-ray examinations in Poland in 2004 in view of the population exposure: The assessment of structure and trends

    International Nuclear Information System (INIS)

    Staniszewska, M. A.; Papierz, S.

    2006-01-01

    The paper presents the results of the Polish national survey of medical x-ray examinations performed in 2004. A questionnaire was used to collect the data on the number and types of x-ray examinations. The data covered most of x-ray laboratories in Poland, being under the dosimetric surveillance performed by the Radiation Protection Department at the Nofer Institute of Occupational Medicine in Lodz. The number of x-ray procedures in Poland in the year 2004 accounted for 32.4 million examinations, i.e. 830 procedures per 1000 inhabitants; the latter figure includes 65 specialist procedures and 61 dental examinations per 1000 of inhabitants, each. They were performed in over 3000 x-ray laboratories, including operational theatres and dental units. The majority of patients were at the age of 40-60 years and women made over 50% of all those examined. Owing to the modification of the heath care organisation, the profile of examinations performed in x-ray laboratories has changed. Nevertheless, conventional x-ray examinations are still in a majority, among which radiograph's of chest, spine and limbs are most frequently performed. It should be emphasised that the number of the hip joint radiograph's in infants and small children have decreased and practically photo fluorographic examinations have been eliminated from the diagnostic practice. The number of specialist procedures has evidently increased, and thus the frequency of these procedures in Poland and other European countries is comparable. (author)

  18. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  19. X-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Zucarias, A; Shepherd, J W

    1982-09-08

    An X-ray tube has a tubular envelope with a cathode for directing an electron beam onto a focal spot area of a spaced anode target to generate X-rays. The target is mounted for axial rotation on one end of a rotor disposed in an end portion of the envelope and encircled by a stator of an alternating current induction motor. An annular shield of high permeability magnetic material extends transversely between the electron beam and the stator of the induction motor for shunting stray or fringe electromagnetic fields established by the stator away from the electron beam to avoid consequent lateral deflections of the electron and corresponding lateral movements of the focal spot area.

  20. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  1. Correlations of DNA strand breaks and their repair with cell survival following acute exposure to mercury(II) and X-rays

    International Nuclear Information System (INIS)

    Cantoni, O.; Costa, M.

    1983-01-01

    Alkaline elution analysis demonstrates that both HgCl 2 and X-rays result in a rapid induction of DNA single-strand breaks at acutely cytotoxic doses (HgCl 2 , 25-100 microM for 60 min; X-rays, 150-600 rads) in cultured Chinese hamster ovary cells. Cytotoxicity, as measured by cell-plating efficiency, correlates linearly with the level of DNA breakage induced by both agents (HgCl 2 , r . 0.97; X-rays, r . 0.99), although a substantial difference in axis intercepts of the two linear regression lines indicates that a higher level of DNA damage was required by X-rays as compared with HgCl 2 to produce an equivalent level of cell killing. DNA damage induced by X-rays was rapidly repaired such that within 1 hr following treatment the elution rate of DNA from treated cells resembled that obtained in untreated cultures. In contrast, DNA damage after Hg 2+ insult was not repaired, and further damage was evident following a similar 1-hr recovery period. Addition of noncytotoxic, non-DNA-damaging concentrations of HgCl 2 (10 microM) to cells 15-45 min following treatment with X-rays greatly inhibited the repair of the DNA strand breaks. Thus, although both HgCl 2 and X-rays induce rapid and striking single-strand breaks in the DNA, persistence of Hg 2+ in the cell can inhibit the repair of these breaks. The inhibition of DNA repair by HgCl 2 may explain why this agent is not severely mutagenic or carcinogenic despite its ability to induce an X-ray-like DNA damage and why a lower level of mercury-induced DNA damage, compared with that induced by X-rays, was required to produce an equivalent level of cell death

  2. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  3. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  4. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  5. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  6. LCLS X-Ray FEL Output Performance in the Presence of Highly Time-Dependent Undulator Wakefields

    CERN Document Server

    Fawley, W M; Emma, P; Huang, Z; Nuhn, H D; Reiche, S; Stupakov, G

    2005-01-01

    Energy loss due to wakefields within a long undulator, if not compensated by an appropriate tapering of the magnetic field strength, can degrade the FEL process by detuning the resonant FEL frequency. The wakefields arise from the vacuum chamber wall resistivity, its surface roughness, and abrupt changes in its aperture. For LCLS parameters, the resistive component is the most critical and depends upon the chamber wall material (e.g. Cu) and its radius. Of recent interest [1] is the so-called "AC" component of the resistive wake which can lead to strong variations on very short timescales (e.g. ~20 fs). To study the expected performance of the LCLS in the presence of these wakefields, we have made an extensive series of start-to-end SASE simulations with tracking codes PARMELA and ELEGANT, and time-dependent FEL simulation codes GENESIS1.3 and GINGER. We discuss the impact of the wakefield losses upon output energy, spectral bandwidth, and temporal envelope of the output FEL pulse, as well a...

  7. New intraoral x-ray fluorographic imaging for dentistry

    International Nuclear Information System (INIS)

    Higashi, T.; Osada, T.; Aoyama, W.; Iguchi, M.; Suzuki, S.; Kanno, M.; Moriya, K.; Yoshimura, M.; Tusuda, M.

    1983-01-01

    A new dental x-ray fluorographic unit has been developed. This unit is composed of small intraoral x-ray tube, a compact x-ray image intensifier, and a high-resolution TV system. The purposes for developing this equipment were to (1) directly observe the tooth during endodontic procedures and (2) reduce x-ray exposure to the patient and the dentist. The radiation exposure can be reduced to about 1/600 the exposure used with conventional dental film. In clinical trials, a satisfactory fluorographic dental image for endodontic treatment was obtained with this new device

  8. Charge recombination process in X-ray irradiated pyrene-doped polystyrene as studied by optically detected electron spin resonance and magnetic field dependence of the recombination fluorescence

    International Nuclear Information System (INIS)

    Okazaki, Masaharu; Tai, Yutaka; Toriyama, Kazumi

    1993-01-01

    The optically-detected ESR (ODESR) spectrum and magnetic field dependence on recombination fluorescence were observed for X-ray irradiated pyrene-doped polystyrene at temperatures of 242-348 K. The ODESR intensity as a function of the pyrene concentration, 0.1-8.9 wt%, showed an unusual minimum at about 1.0%. Two phases were separated in the magnetic field dependence of the fluorescence: one was sharp and saturates at fields of over 50 mT, while the other was broad with a dip at around 60-150 mT. The cause of this dip was naturally attributed to the ST -1 level crossing. The sharp magnetic field effect also showed a minimum at around a concentration of 1.0 wt%. These novel findings have been interpreted using a recombination model modified from the previous one for pyrene-doped ethylene-propylene rubber and polyethylene. The essential points of the present model are: (1) although electron hopping within the polystyrene molecule is rapid, electron transfer at the last step of recombination between the polystyrene anion and the pyrene cation proceeds at a moderate rate; (2) the hole-transfer rate in the polymer chain is moderate; (3) electron hopping between the doped pyrene molecules is very much dependent on the concentration; (4) hole hopping between the pyrenes is inhibited. (author)

  9. Relationship medical exposure in X-ray diagnosis and loading factor and film/screen system for reduction exposure dose in Aomori. An analysis based on the results of questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A fact-finding questionnaire survey on medical exposure in Aomori Prefecture was conducted in September 1998. Of the 23 exposed sites in the body investigated, exposure at 17 sites in adults was investigated in terms of the type of high-voltage generator, imaging conditions (X-ray tube voltage, electric current, exposure time, etc.), photosensitive materials and relative photosensitivity, and entrance surface doses. At 6 of the 17 exposed sites, the relationships between these technical conditions and entrance surface doses were analyzed to consider further reduction of medical exposure. The most frequently used high-voltage generators were inverter generators (about 52%). In many institutions, additional filters were utilized for high-voltage imaging of the chest. Highly sensitive green-emission materials were the most frequently used photosensitive materials (73%). These findings indicate that many institutions are attempting to reduce exposure. Entrance surface doses varied greatly among institutions: and a 100-fold difference was observed in exposure to the chest, Martius, and the pelvis. Further efforts to lower entrance surface doses are therefore necessary to reduce medical exposure. Negative correlations were observed between electric voltage, electric current, and exposure time. Examination of the relationships between entrance surface doses, electric current, and exposure time yielded positive correlations. However, the entrance surface doses may not have been properly calculated in some institutions, and examination of the relationship between the relative sensitivity of the sensitive material and entrance surface doses showed great variability in entrance surface doses between institutions. Based on the above results, it is concluded that further reduction of medical exposure is possible, not only by improving the accuracy of X-ray units/devices, but by choosing a more appropriate of conditions to perform radiography. (K.H.)

  10. Purification, crystallization and preliminary X-ray diffraction analysis of the RNA-dependent RNA polymerase from Thosea asigna virus

    International Nuclear Information System (INIS)

    Ferrero, Diego; Buxaderas, Mònica; Rodriguez, José F.; Verdaguer, Núria

    2012-01-01

    The RNA-dependent RNA polymerase of Thosea asigna virus has been purified and crystallized in two different crystal forms. Preliminary characterization of P2 1 2 1 2 and C222 1 crystals is reported. Co-crystallization experiments in the presence of lutetium produced a heavy-atom derivative suitable for structure determination. Thosea asigna virus (TaV) is a positive-sense, single-stranded RNA (ssRNA) virus that belongs to the Permutotetravirus genera within the recently created Permutotetraviridae family. The genome of TaV consists of an RNA segment of about 5.700 nucleotides with two open reading frames, encoding for the replicase and capsid protein. The particular TaV replicase does not contain N7-methyl transferase and helicase domains but includes a structurally unique RNA-dependent RNA polymerase (RdRp) with a sequence permutation in the domain where the active site is anchored. This architecture is also found in double-stranded RNA viruses of the Birnaviridae family. Here we report the purification and preliminary crystallographic studies TaV RdRp. The enzyme was crystallized by the sitting-drop vapour diffusion method using PEG 8K and lithium sulfate as precipitants. Two different crystal forms were obtained: native RdRp crystallized in space group P2 1 2 1 2 and diffracts up to 2.1 Å and the RdRp-Lu 3+ derivative co-crystals belong to the C222 1 space group, diffracting to 3.0 Å resolution. The structure of TaV RdRp represents the first structure of a non-canonical RdRp from ssRNA viruses

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  15. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... changes seen in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... conditions. Imaging with x-rays involves exposing a part of the body to a small dose of ... body. Once it is carefully aimed at the part of the body being examined, an x-ray ...

  3. Room-temperature X-ray diffraction studies of cisplatin and carboplatin binding to His15 of HEWL after prolonged chemical exposure

    International Nuclear Information System (INIS)

    Tanley, Simon W. M.; Schreurs, Antoine M. M.; Kroon-Batenburg, Loes M. J.; Helliwell, John R.

    2012-01-01

    Binding of cisplatin to His15 in hen egg-white lysozyme in aqueous media is observed after prolonged chemical exposure for 15 months, in contrast to the lack of binding that was observed after 4 d in a previous study. Binding of carboplatin is seen in greater detail in the case of room-temperature data collection compared with cryo data collection. The anticancer complexes cisplatin and carboplatin are known to bind to both the N δ and the N ∊ atoms of His15 of hen egg-white lysozyme (HEWL) in the presence of dimethyl sulfoxide (DMSO). However, neither binds in aqueous media after 4 d of crystallization and crystal growth, suggesting that DMSO facilitates cisplatin/carboplatin binding to the N atoms of His15 by an unknown mechanism. Crystals of HEWL cocrystallized with cisplatin in both aqueous and DMSO media, of HEWL cocrystallized with carboplatin in DMSO medium and of HEWL cocrystallized with cisplatin and N-acetylglucosamine (NAG) in DMSO medium were stored for between seven and 15 months. X-ray diffraction studies of these crystals were carried out on a Bruker APEX II home-source diffractometer at room temperature. Room-temperature X-ray diffraction data collection removed the need for cryoprotectants to be used, ruling out any effect that the cryoprotectants might have had on binding to the protein. Both cisplatin and carboplatin still bind to both the N δ and N ∊ atoms of His15 in DMSO media as expected, but more detail for the cyclobutanedicarboxylate (CBDC) moiety of carboplatin was observed at the N ∊ binding site. However, two molecules of cisplatin were now observed to be bound to His15 in aqueous conditions. The platinum peak positions were identified using anomalous difference electron-density maps as a cross-check with F o − F c OMIT electron-density maps. The occupancies of each binding site were calculated using SHELXTL. These results show that over time cisplatin binds to both N atoms of His15 of HEWL in aqueous media, whereas this

  4. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value; Erarbeitung eines Konzepts zur Ermittlung der Strahlenexposition von Patienten bei zahnmedizinischen Roentgenuntersuchungen und Erhebung von statistischen Daten zur Erstellung diagnostischer Referenzwerten

    Energy Technology Data Exchange (ETDEWEB)

    Kueppers, C.; Sering, M. [Oekoinstitut Freiburg e.V., Freiburg (Germany); Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F. [Pius Hospital, Oldenburg (Germany)

    2012-02-15

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  5. Analyzing three-dimensional position of region of interest using an image of contrast media using unilateral X-ray exposure

    International Nuclear Information System (INIS)

    Harauchi, Hajime; Gotou, Hiroshi; Tanooka, Masao

    1994-01-01

    Analyzing three-dimensional internal structure of object in an X-ray study is usually performed by using two or more of the incidents of an X-ray direction. In this report, we analyzed the three-dimensional position of tubes with a phantom by using both contrast media and imaging of one direction in the X-ray study. The concentration of the iodine in contrast media can be known by using the log-subtraction image of only the one-directional incident X-ray. Also the diameter of tube filled with contrast media is calculated by the concentration of iodine. So we can show the three-dimensional position of tubes geometrically, by the diameter of tube and the measured value of the film. We verified this method by an experiment according to the theory. (author)

  6. Correlation between Co-60 and X-ray exposures on radiation-induced charge buildup in silicon-on-insulator buried oxides

    International Nuclear Information System (INIS)

    Schwank, James R.; Shaneyfelt, Marty R.; Loemker, Rhonda Ann; Draper, Bruce L.; Dodd, Paul E.; Witczak, StevenN C.; Riewe, Leonard Charles; Ferlet-Cavrois, V.; Paillet, P.; Leray, J.-L.; Fleetwood, D.M.

    2000-01-01

    Large differences in charge buildup in SOI buried oxides can result between x-ray and Co-60 irradiations. The effects of bias configuration and substrate type on charge buildup and hardness assurance issues are explored

  7. Quality control in veterinary radiology: application of X-ray sets in veterinary practices and measurements of radiation exposure at taking

    International Nuclear Information System (INIS)

    Horvat, C.

    1986-10-01

    In a first part a survey was made by questionnaires from veterinary doctors about the existence and use of X-ray sets in their practices. Special attention is given to the quality of X-ray shots. In part two stray radiation measurements under typical conditions were performed and the radiation burden of the personnel estimated. The results is that because of the small number of shots the burden is safely below the legal limits. (G.Q.)

  8. Perfect-crystal x-ray optics to treat x-ray coherence

    International Nuclear Information System (INIS)

    Yamazaki, Hiroshi; Ishikawa, Tetsuya

    2007-01-01

    X-ray diffraction of perfect crystals, which serve as x-ray monochromator and collimator, modifies coherence properties of x-ray beams. From the time-dependent Takagi-Taupin equations that x-ray wavefields obey in crystals, the reflected wavefield is formulated as an integral transform of a general incident wavefield with temporal and spatial inhomogeneity. A reformulation of rocking-curve profiles from the field solution of the Takagi-Taupin equations allows experimental evaluation of the mutual coherence function of x-ray beam. The rigorous relationship of the coherence functions between before and after reflection clarifies how the coherence is transferred by a crystal. These results will be beneficial to developers of beamline optics for the next generation synchrotron sources. (author)

  9. X-ray safety at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Gutierrez, J.A.

    1986-11-01

    An organized and structured safety program for x-ray generating devices was initiated in October, 1979. An X-ray Device Control Office was established to manage the program that currently oversees the activities of 201 x-ray generating devices and to provide SOP reviews, perform shielding calculations, and provide training for both the operators and health physics x-ray device surveyors. The new program also establishes controls for procurement of new equipment, requires the writing of Standard Operating Procedures, requires training for operators and provides routine and non-routine safety inspections of x-ray generating devices. Prior to this program going into effect, the Laboratory had recorded nine documented x-ray related exposure accidents. Since then, there have been none. Program elements and experiences of interest to other x-ray device users are discussed. 3 refs

  10. Angular dependence of Ll, L $\\alpha$ , L $\\beta$ and L $\\gamma$ X-ray differential and fluorescence cross-sections for Er, Ta, W, Au, Hg and Tl

    CERN Document Server

    Demir, L; Kurucu, Y; Karabulut, A; Sahin, Y; 10.1016/S0969-806X(02)00501-7

    2003-01-01

    Ll, L alpha , L beta and L gamma X-ray differential cross-sections, fluorescence cross-sections and L/sub i/-subshell ( sigma /sub L1/, sigma /sub L2/, and sigma /sub L3/) fluorescence cross-sections were measured for Er, Ta, W, Au, Hg, and Tl at an excitation energy of 59.6 keV using a Si(Li) detector. The differential cross-sections for these elements have been measured at different angles varying from 54 degrees to 153 degrees at intervals of 9 degrees . The Ll and L alpha groups in the L X-ray lines are found to be spatially anisotropic, while those in the L beta and L gamma peaks are isotropic. Experimental and theoretical values of L X-ray fluorescence cross- sections and L/sub i/-subshell X-ray fluorescence cross-sections were compared. (20 refs).

  11. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The x-ray tube is connected to a flexible arm that is extended over the patient while an x-ray film holder or image recording plate is placed beneath the patient. top of page How does the procedure work? X-rays are a form of radiation like ...

  15. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  16. Air ionizatio at X-ray departments

    International Nuclear Information System (INIS)

    Vesela, O.; Mosatova, A.; Kubova, Z.

    1987-01-01

    Changes in electroionic microclimate are dealt with at X-ray workplaces and their dynamics in the course of the day during normal operation. Following exposure to X-ray radiation the specific concentration of light air ions of both polarities increases due to increased input of ionization energy. Within the first minutes following the termination of exposure a sharp decline takes place in the specific concentration of light air ions with subsequent well of positive ions in the air. (author). 1 tab., 19 refs

  17. X-ray tube technology update

    International Nuclear Information System (INIS)

    Rehani, M.M.

    1997-01-01

    During the 100 years since the discovery of x-rays, the x-ray tube has undergone significant improvements to meet the demand of shorter exposure time and frequent exposures as in angiography. This has been achieved by multiple focal spots, rotating anodes, design consideration of the anode and the tube assembly. While physical improvements have resulted in improved performance, the principle has remained the same, as also has the problem of massive heat generation which consumes almost 99% of the energy. This article traces the history of tubes and current perspectives. (author). 3 refs., 3 figs., 2 tabs

  18. Polarization dependence of resonant X-ray emission spectra in 3dn transition metal compounds with n=0, 1, 2, 3

    International Nuclear Information System (INIS)

    Matsubara, Masahiko; Kotani, Akio; Shin, Shik; Uozumi, Takayuki; Harada, Yoshihisa

    2002-01-01

    The polarization dependence of 2p → 3d → 2p resonant X-ray emission spectroscopy (RXES) in 3d 1 , 3d 2 and 3d 3 systems (TiF 3 , VF 3 and Cr 2 O 3 , respectively) is measured and analyzed by means of the MX 6 (M denotes a transition metal and X denotes a ligand, respectively) cluster model. The results are compared with a previous one for the 3d 0 system (TiO 2 ). Generally, with increasing 3d electron number, the spectral structure of RXES becomes more complicated by the influence of the crystal field and the multiplet coupling effect. Moreover, we point out that the selection rules on the polarization dependence of RXES change with the 3d electron number and that a drastic resonance enhancement corresponding to the excitation to an antibonding state in the 3d 0 system is almost absent for the 3d n systems with n=1, 2 and 3. (author)

  19. Assignment of near-edge x-ray absorption fine structure spectra of metalloporphyrins by means of time-dependent density-functional calculations

    International Nuclear Information System (INIS)

    Schmidt, Norman; Fink, Rainer; Hieringer, Wolfgang

    2010-01-01

    The C 1s and N 1s near-edge x-ray absorption fine structure (NEXAFS) spectra of three prototype tetraphenyl porphyrin (TPP) molecules are discussed in the framework of a combined experimental and theoretical study. We employ time-dependent density-functional theory (TDDFT) to compute the NEXAFS spectra of the open- and closed-shell metalloporphyrins CoTPP and ZnTPP as well as the free-base 2HTPP in realistic nonplanar conformations. Using Becke's well-known half-and-half hybrid functional, the computed core excitation spectra are mostly in good agreement with the experimental data in the low-energy region below the appropriate ionization threshold. To make these calculations feasible, we apply a new, simple scheme based on TDDFT using a modified single-particle input spectrum. This scheme is very easy to implement in standard codes and allows one to compute core excitation spectra at a similar cost as ordinary UV/vis spectra even for larger molecules. We employ these calculations for a detailed assignment of the NEXAFS spectra including subtle shifts in certain peaks of the N 1s spectra, which depend on the central coordination of the TPP ligand. We furthermore assign the observed NEXAFS resonances to the individual molecular subunits of the investigated TPP molecules.

  20. Temperature dependent evolution of the local electronic structure of atmospheric plasma treated carbon nanotubes: Near edge x-ray absorption fine structure study

    International Nuclear Information System (INIS)

    Roy, S. S.; Papakonstantinou, P.; Okpalugo, T. I. T.; Murphy, H.

    2006-01-01

    Near edge x-ray absorption fine structure (NEXAFS) spectroscopy has been employed to obtain the temperature dependent evolution of the electronic structure of acid treated carbon nanotubes, which were further modified by dielectric barrier discharge plasma processing in an ammonia atmosphere. The NEXAFS studies were performed from room temperature up to 900 deg. C. The presence of oxygen and nitrogen containing functional groups was observed in C K edge, N K edge, and O K edge NEXAFS spectra of the multiwalled carbon nanotubes. The N K edge spectra revealed three types of π* features, the source of which was decisively identified by their temperature dependent evolution. It was established that these features are attributed to pyridinelike, NO, and graphitelike structures, respectively. The O K edge indicated that both carbonyl (C=O), π*(CO), and ether C-O-C, σ*(CO), functionalities were present. Upon heating in a vacuum to 900 deg. C the π*(CO) resonances disappeared while the σ*(CO) resonances were still present confirming their higher thermal stability. Heating did not produce a significant change in the π* feature of the C K edge spectrum indicating that the tabular structure of the nanotubes is essentially preserved following the thermal decomposition of the functional groups on the nanotube surface