WorldWideScience

Sample records for explains magnetic-sensitive reaction

  1. Magnetic field and magnetic isotope effects on photochemical reactions

    International Nuclear Information System (INIS)

    Wakasa, Masanobu

    1999-01-01

    By at present exact experiments and the theoretical analysis, it was clear that the magnetic field less than 2 T affected a radical pair reaction and biradical reaction. The radical pair life and the dissipative radical yield showed the magnetic field effects on chemical reactions. The radical pair mechanism and the triplet mechanism were known as the mechanism of magnetic field effects. The radical pair mechanism consists of four mechanisms such as the homogeneous hyperfine interaction (HFC), the delta-g mechanism, the relaxation mechanism and the level cross mechanism. In order to observe the magnetic effects of the radical pair mechanism, two conditions need, namely, the recombination rate of singlet radical pair > the dissipation rate and the spin exchange rate > the dissipation rate. A nanosecond laser photo-decomposition equipment can observe the magnetic field effects. The inversion phenomena of magnetic field effect, isolation of the relaxation mechanism and the delta-g mechanism, the magnetic field effect of heavy metal radical reaction, the magnetic field effect in homogeneous solvent, saturation of delta-g mechanism are explained. The succeeded examples of isotope concentration by the magnetic isotope effect are 17 O, 19 Si, 33 S, 73 Ge and 235 U. (S.Y.)

  2. Magnetic actuator for the control and mixing of magnetic bead-based reactions on-chip.

    Science.gov (United States)

    Berenguel-Alonso, Miguel; Granados, Xavier; Faraudo, Jordi; Alonso-Chamarro, Julián; Puyol, Mar

    2014-10-01

    While magnetic bead (MB)-based bioassays have been implemented in integrated devices, their handling on-chip is normally either not optimal--i.e. only trapping is achieved, with aggregation of the beads--or requires complex actuator systems. Herein, we describe a simple and low-cost magnetic actuator to trap and move MBs within a microfluidic chamber in order to enhance the mixing of a MB-based reaction. The magnetic actuator consists of a CD-shaped plastic unit with an arrangement of embedded magnets which, when rotating, generate the mixing. The magnetic actuator has been used to enhance the amplification reaction of an enzyme-linked fluorescence immunoassay to detect Escherichia coli O157:H7 whole cells, an enterohemorrhagic strain, which have caused several outbreaks in food and water samples. A 2.7-fold sensitivity enhancement was attained with a detection limit of 603 colony-forming units (CFU) /mL, when employing the magnetic actuator.

  3. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation

    NARCIS (Netherlands)

    Dittmer, W.U.; Kievit, de P.; Prins, M.W.J.; Vissers, J.L.M.; Mersch, M.E.C.; Martens, M.F.W.C.

    2008-01-01

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions

  4. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  5. An investigation of nuclear critical opalescence with photopion reactions

    International Nuclear Information System (INIS)

    Delorme, J.

    1981-01-01

    It is shown that photopion reactions on nuclei provide a direct probe of the enhancement of the virtual pion field (critical opalescence) which has been invoked to explain anomalies in 1p-shell magnetic form factors. The experimental conditions for maximum sensitivity are discussed. (author)

  6. Magnetic isotope effect and theory of atomic orbital hybridization to predict a mechanism of chemical exchange reactions.

    Science.gov (United States)

    Epov, Vladimir N

    2011-08-07

    A novel approach is suggested to investigate the mechanisms of chemical complexation reactions based on the results of Fujii with co-workers; they have experimentally observed that several metals and metalloids demonstrate mass-independent isotope fractionation during the reactions with the DC18C6 crown ether using solvent-solvent extraction. In this manuscript, the isotope fractionation caused by the magnetic isotope effect is used to understand the mechanisms of chemical exchange reactions. Due to the rule that reactions are allowed for certain electron spin states, and forbidden for others, magnetic isotopes show chemical anomalies during these reactions. Mass-independent fractionation is suggested to take place due to the hyperfine interaction of the nuclear spin with the electron spin of the intermediate product. Moreover, the sign of the mass-independent fractionation is found to be dependent on the element and its species, which is also explained by the magnetic isotope effect. For example, highly negative mass-independent isotope fractionation of magnetic isotopes was observed for reactions of DC18C6 with SnCl(2) species and with several Ru(III) chloro-species, and highly positive for reactions of this ether with TeCl(6)(2-), and with several Cd(II) and Pd(II) species. The atomic radius of an element is also a critical parameter for the reaction with crown ether, particularly the element ions with [Kr]4d(n)5s(m) electron shell fits the best with the DC18C6 crown ring. It is demonstrated that the magnetic isotope effect in combination with the theory of orbital hybridization can help to understand the mechanism of complexation reactions. The suggested approach is also applied to explain previously published mass-independent fractionation of Hg isotopes in other types of chemical exchange reactions. This journal is © the Owner Societies 2011

  7. A basal magma ocean dynamo to explain the early lunar magnetic field

    Science.gov (United States)

    Scheinberg, Aaron L.; Soderlund, Krista M.; Elkins-Tanton, Linda T.

    2018-06-01

    The source of the ancient lunar magnetic field is an unsolved problem in the Moon's evolution. Theoretical work invoking a core dynamo has been unable to explain the magnitude of the observed field, falling instead one to two orders of magnitude below it. Since surface magnetic field strength is highly sensitive to the depth and size of the dynamo region, we instead hypothesize that the early lunar dynamo was driven by convection in a basal magma ocean formed from the final stages of an early lunar magma ocean; this material is expected to be dense, radioactive, and metalliferous. Here we use numerical convection models to predict the longevity and heat flow of such a basal magma ocean and use scaling laws to estimate the resulting magnetic field strength. We show that, if sufficiently electrically conducting, a magma ocean could have produced an early dynamo with surface fields consistent with the paleomagnetic observations.

  8. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  9. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  10. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation.

    Science.gov (United States)

    Dittmer, W U; de Kievit, P; Prins, M W J; Vissers, J L M; Mersch, M E C; Martens, M F W C

    2008-09-30

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions as well as the bound/free separation are entirely controlled by magnetic forces induced by electromagnets above and below the sensor chip. During the assay, particles conjugated with tracer antibodies are actuated through the sample for target capture, and rapidly brought to the sensor surface where they bind to immobilized capture antibodies. Weakly or unbound labels are removed with a magnetic force oriented away from the GMR sensor surface. For the measurement of parathyroid hormone (PTH), a detection limit in the 10 pM range is obtained with a total assay time of 15 min when 300 nm particles are used. The same sensitivity can be achieved in 5 min when 500 nm particles are used. If 500 nm particles are employed in a 15-minute assay, then 0.8 pM of PTH is detectable. The low sample volume, high analytical performance and high speed of the test coupled with the compact GMR biosensor make the system especially suitable for sensitive testing outside of laboratory environments.

  11. Rapid and sensitive electrochemiluminescence detection of rotavirus by magnetic primer based reverse transcription-polymerase chain reaction

    International Nuclear Information System (INIS)

    Zhan Fangfang; Zhou Xiaoming; Xing Da

    2013-01-01

    Graphical abstract: In this work, we have developed and demonstrated a magnetic primer based RT-PCR assay for ECL detection of rotavirus. In the presence of two functional primers (magnetic primer and TBR-primer) and PCR reagents, cDNA from RT was amplified directly onto MPs during PCR cycles of denaturation, annealing and extension. The resulting MPs–TBR complexes were easily loaded on the electrode surface and produced a concentrated ECL signal. The figure shows the schematic illustration of magnetic primer RT-PCR based ECL assay for rotavirus detection. Highlights: ► A novel method for detection of rotavirus has been developed. ► In the presence of magnetic primer, TBR-primer and PCR reagents, cDNA form RT was amplified directly onto MPs. ► To obtain the best sensing and efficient performance, important parameters associated with the efficiency were investigated carefully. ► The proposed method will find numerous applications in food safety field and clinical diagnosis. - Abstract: A novel method for detection of rotavirus has been developed by integrating magnetic primer based reverse transcription-polymerase chain reaction (RT-PCR) with electrochemiluminescence (ECL) detection. This is realized by accomplishing RT of rotavirus RNA in traditional way and performing PCR of the resulting cDNA fragment on the surface of magnetic particles (MPs). In order to implement PCR on MPs and achieve rapid ECL detection, forward and reverse primers are bounded to MPs and tris-(2,2′-bipyridyl) ruthenium (TBR), respectively. After RT-PCR amplification, the TBR labels are directly enriched onto the surface of MPs. Then the MPs–TBR complexes can be loaded on the electrode surface and analyzed by magnetic ECL platform without any post-modification or post-incubation process. So some laborious manual operations can be avoided to achieve rapid yet sensitive detection. In this study, rotavirus in fecal specimens was successfully detected within 1.5 h. Experimental

  12. Sensitive magnetic biodetection using magnetic multi-core nanoparticles and RCA coils

    Energy Technology Data Exchange (ETDEWEB)

    Ahrentorp, Fredrik; Blomgren, Jakob; Jonasson, Christian; Sarwe, Anna [Acreo Swedish ICT AB, Arvid Hedvalls Backe 4, Göteborg (Sweden); Sepehri, Sobhan; Eriksson, Emil; Kalaboukhov, Alexei; Jesorka, Aldo; Winkler, Dag [Department of Microtechnology and Nanoscience – MC2, Chalmers University of Technology, Göteborg (Sweden); Schneiderman, Justin F. [Institute of Neuroscience and Physiology, University of Gothenburg and MedTech West, Göteborg (Sweden); Nilsson, Mats [Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Stockholm (Sweden); Albert, Jan [Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, Stockholm (Sweden); Department of Clinical Microbiology, Karolinska University Hospital, Stockholm (Sweden); Zardán Gómez de la Torre, Teresa; Strømme, Maria [Uppsala University, Uppsala (Sweden); Johansson, Christer, E-mail: christer.johansson@acreo.se [Acreo Swedish ICT AB, Arvid Hedvalls Backe 4, Göteborg (Sweden)

    2017-04-01

    We use functionalized iron oxide magnetic multi-core particles of 100 nm in size (hydrodynamic particle diameter) and AC susceptometry (ACS) methods to measure the binding reactions between the magnetic nanoparticles (MNPs) and bio-analyte products produced from DNA segments using the rolling circle amplification (RCA) method. We use sensitive induction detection techniques in order to measure the ACS response. The DNA is amplified via RCA to generate RCA coils with a specific size that is dependent on the amplification time. After about 75 min of amplification we obtain an average RCA coil diameter of about 1 µm. We determine a theoretical limit of detection (LOD) in the range of 11 attomole (corresponding to an analyte concentration of 55 fM for a sample volume of 200 µL) from the ACS dynamic response after the MNPs have bound to the RCA coils and the measured ACS readout noise. We also discuss further possible improvements of the LOD. - Highlights: • Biosensing using Brownian relaxation of functionalized magnetic nanoparticles. • Rolling circle amplification and magnetic nanoparticles enables biosensing. • Theoretical limit of detection estimated from the signal noise gives about 55 fM.

  13. Rapid and sensitive electrochemiluminescence detection of rotavirus by magnetic primer based reverse transcription-polymerase chain reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zhan Fangfang; Zhou Xiaoming [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China); Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2013-01-25

    Graphical abstract: In this work, we have developed and demonstrated a magnetic primer based RT-PCR assay for ECL detection of rotavirus. In the presence of two functional primers (magnetic primer and TBR-primer) and PCR reagents, cDNA from RT was amplified directly onto MPs during PCR cycles of denaturation, annealing and extension. The resulting MPs-TBR complexes were easily loaded on the electrode surface and produced a concentrated ECL signal. The figure shows the schematic illustration of magnetic primer RT-PCR based ECL assay for rotavirus detection. Highlights: Black-Right-Pointing-Pointer A novel method for detection of rotavirus has been developed. Black-Right-Pointing-Pointer In the presence of magnetic primer, TBR-primer and PCR reagents, cDNA form RT was amplified directly onto MPs. Black-Right-Pointing-Pointer To obtain the best sensing and efficient performance, important parameters associated with the efficiency were investigated carefully. Black-Right-Pointing-Pointer The proposed method will find numerous applications in food safety field and clinical diagnosis. - Abstract: A novel method for detection of rotavirus has been developed by integrating magnetic primer based reverse transcription-polymerase chain reaction (RT-PCR) with electrochemiluminescence (ECL) detection. This is realized by accomplishing RT of rotavirus RNA in traditional way and performing PCR of the resulting cDNA fragment on the surface of magnetic particles (MPs). In order to implement PCR on MPs and achieve rapid ECL detection, forward and reverse primers are bounded to MPs and tris-(2,2 Prime -bipyridyl) ruthenium (TBR), respectively. After RT-PCR amplification, the TBR labels are directly enriched onto the surface of MPs. Then the MPs-TBR complexes can be loaded on the electrode surface and analyzed by magnetic ECL platform without any post-modification or post-incubation process. So some laborious manual operations can be avoided to achieve rapid yet sensitive detection

  14. Nuclear reactions in ultra-magnetized supernovae

    International Nuclear Information System (INIS)

    Kondratyev, V.N.

    2002-06-01

    The statistical model is employed to investigate nuclear reactions in ultrastrong magnetic fields relevant for supernovae and neutron stars. For radiative capture processes the predominant mechanisms are argued to correspond to modifications of nuclear level densities, and γ-transition energies due to interactions of the field with magnetic moments of nuclei. The density of states reflects the nuclear structure and results in oscillations of reaction cross sections as a function of field strength, while magnetic interaction energy enhances radiative neutron capture process. Implications in the synthesis of r-process nuclei in supernova site are discussed. (author)

  15. Probabilistic sensitivity analysis of biochemical reaction systems.

    Science.gov (United States)

    Zhang, Hong-Xuan; Dempsey, William P; Goutsias, John

    2009-09-07

    Sensitivity analysis is an indispensable tool for studying the robustness and fragility properties of biochemical reaction systems as well as for designing optimal approaches for selective perturbation and intervention. Deterministic sensitivity analysis techniques, using derivatives of the system response, have been extensively used in the literature. However, these techniques suffer from several drawbacks, which must be carefully considered before using them in problems of systems biology. We develop here a probabilistic approach to sensitivity analysis of biochemical reaction systems. The proposed technique employs a biophysically derived model for parameter fluctuations and, by using a recently suggested variance-based approach to sensitivity analysis [Saltelli et al., Chem. Rev. (Washington, D.C.) 105, 2811 (2005)], it leads to a powerful sensitivity analysis methodology for biochemical reaction systems. The approach presented in this paper addresses many problems associated with derivative-based sensitivity analysis techniques. Most importantly, it produces thermodynamically consistent sensitivity analysis results, can easily accommodate appreciable parameter variations, and allows for systematic investigation of high-order interaction effects. By employing a computational model of the mitogen-activated protein kinase signaling cascade, we demonstrate that our approach is well suited for sensitivity analysis of biochemical reaction systems and can produce a wealth of information about the sensitivity properties of such systems. The price to be paid, however, is a substantial increase in computational complexity over derivative-based techniques, which must be effectively addressed in order to make the proposed approach to sensitivity analysis more practical.

  16. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    Science.gov (United States)

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Method and device for thermal control of biological and chemical reactions using magnetic particles or magnetic beads and variable magnetic fields

    OpenAIRE

    Zilch, C.; Gerdes, W.; Bauer, J.; Holschuh, K.

    2009-01-01

    The invention relates to a method for the thermal control of at least one temperature-dependent enzymatic reaction in the presence of magnetic particles, particularly nanoparticles, or magnetic beads, in vitro by heating the magnetic beads or magnetic particles to at least one defined target temperature using alternating magnetic fields. The thermally controllable enzymatic reaction carried out with the method according to the invention is preferably a PCR reaction or another reaction for elo...

  18. Magnetic resonance imaging in the evaluation of periosteal reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino, E-mail: marcello@fmrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Sa, Jose Luiz de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Oliveira, Rodrigo Cecilio Vieira de [Clinica de Diagnostico por Imagem Tomoson, Aracatuba, SP (Brazil); Engel, Edgard Eduard [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Biomecanica, Medicina e Reabilitacao do Aparelho Locomotor

    2010-07-15

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  19. Magnetic resonance imaging in the evaluation of periosteal reactions

    International Nuclear Information System (INIS)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino; Engel, Edgard Eduard

    2010-01-01

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  20. Highly sensitive magnetic field sensor based on microfiber coupler with magnetic fluid

    International Nuclear Information System (INIS)

    Luo, Longfeng; Pu, Shengli; Tang, Jiali; Zeng, Xianglong; Lahoubi, Mahieddine

    2015-01-01

    A kind of magnetic field sensor using a microfiber coupler (MFC) surrounded with magnetic fluid (MF) is proposed and experimentally demonstrated. As the MFC is strongly sensitive to the surrounding refractive index (RI) and MF's RI is sensitive to magnetic field, the magnetic field sensing function of the proposed structure is realized. Interrogation of magnetic field strength is achieved by measuring the dip wavelength shift and transmission loss change of the transmission spectrum. The experimental results show that the sensitivity of the sensor is wavelength-dependent. The maximum sensitivity of 191.8 pm/Oe is achieved at wavelength of around 1537 nm in this work. In addition, a sensitivity of −0.037 dB/Oe is achieved by monitoring variation of the fringe visibility. These suggest the potential applications of the proposed structure in tunable all-in-fiber photonic devices such as magneto-optical modulator, filter, and sensing

  1. Highly sensitive magnetic field sensor based on microfiber coupler with magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Longfeng; Pu, Shengli, E-mail: shlpu@usst.edu.cn; Tang, Jiali [College of Science, University of Shanghai for Science and Technology, Shanghai 200093 (China); Zeng, Xianglong [2Key Laboratory of Specialty Fiber Optics and Optical Access Network, Shanghai University, Shanghai 200072 (China); Lahoubi, Mahieddine [Department of Physics, Faculty of Sciences, Laboratory L.P.S., Badji Mokhtar-Annaba University, P. O. Box 12, 23000 Annaba (Algeria)

    2015-05-11

    A kind of magnetic field sensor using a microfiber coupler (MFC) surrounded with magnetic fluid (MF) is proposed and experimentally demonstrated. As the MFC is strongly sensitive to the surrounding refractive index (RI) and MF's RI is sensitive to magnetic field, the magnetic field sensing function of the proposed structure is realized. Interrogation of magnetic field strength is achieved by measuring the dip wavelength shift and transmission loss change of the transmission spectrum. The experimental results show that the sensitivity of the sensor is wavelength-dependent. The maximum sensitivity of 191.8 pm/Oe is achieved at wavelength of around 1537 nm in this work. In addition, a sensitivity of −0.037 dB/Oe is achieved by monitoring variation of the fringe visibility. These suggest the potential applications of the proposed structure in tunable all-in-fiber photonic devices such as magneto-optical modulator, filter, and sensing.

  2. Magnetically sensitive nanodiamond-doped tellurite glass fibers.

    Science.gov (United States)

    Ruan, Yinlan; Simpson, David A; Jeske, Jan; Ebendorff-Heidepriem, Heike; Lau, Desmond W M; Ji, Hong; Johnson, Brett C; Ohshima, Takeshi; Afshar V, Shahraam; Hollenberg, Lloyd; Greentree, Andrew D; Monro, Tanya M; Gibson, Brant C

    2018-01-19

    Traditional optical fibers are insensitive to magnetic fields, however many applications would benefit from fiber-based magnetometry devices. In this work, we demonstrate a magnetically sensitive optical fiber by doping nanodiamonds containing nitrogen vacancy centers into tellurite glass fibers. The fabrication process provides a robust and isolated sensing platform as the magnetic sensors are fixed in the tellurite glass matrix. Using optically detected magnetic resonance from the doped nanodiamonds, we demonstrate detection of local magnetic fields via side excitation and longitudinal collection. This is a first step towards intrinsically magneto-sensitive fiber devices with future applications in medical magneto-endoscopy and remote mineral exploration sensing.

  3. 125I-Fibrin deposition in contact sensitivity reactions in the mouse. Sensitivity of the assay for quantitating reactions after active or passive sensitization

    International Nuclear Information System (INIS)

    Mekori, Y.A.; Dvorak, H.F.; Galli, S.J.

    1986-01-01

    The clotting associated with delayed hypersensitivity (DH) responses in the mouse by sensitizing the animals to the contactant oxazolone (Ox), and then administering 125 I-guinea pig fibrinogen i.v. 10 to 30 min before antigen challenge 5 days later. Early (4 to 8 hr) contact sensitivity (CS) responses in immunized mice were barely detectable by three conventional measures of CS, but the total 125 I-cpm in ears challenged with hapten was 3.6 to 4.5 x that in control ears challenged with vehicle alone; moreover, the amount of urea-insoluble cpm (cross-linked 125 I-fibrin-associated cpm) in the reactions to Ox was 6.5-fold to 8.2-fold that present in the control reactions. In 24 hr reactions that were near peak intensity by measurements of ear swelling, ear weight ratios, and ratios of 125 I-5-iodo-2-deoxyuridine-labeled leukocyte infiltration, the cpm in antigen-challenged ears exceeded that in control ears by 13-fold to 53-fold. In addition, antigen-challenged ears contained 27 to 300 x the urea-insoluble cpm present in control ears. 125 I-Fibrin deposition was not a specific characteristic of CS reactions, because a small amount of urea-insoluble reactivity was also detected in some reactions to Ox in native mice. Nevertheless, the assay was exquisitely sensitive and readily detected quantitative differences between the immunologically specific and nonspecific reactions at very early intervals after challenge or with suboptimal doses of antigen

  4. Magnetic Field Effects on Photoelectrochemical Reactions of Porphyrin-Viologen Linked Compounds in an Ionic Liquid

    Science.gov (United States)

    Tahara, Hironobu; Yonemura, Hiroaki; Harada, Satoko; Yamada, Sunao

    2011-08-01

    Magnetic field effects (MFEs) on photoelectrochemical reactions of three porphyrin-viologen linked compounds with various methylene groups [ZnP(n)V (n=4,6,8)] were examined in 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF4]) as an ionic liquid using a two-electrode cell. Stable anodic photocurrents are produced by irradiating ZnP(n)V (n=4,6,8) in [BMIM][BF4] with visible light, and the MFEs on photocurrents were clearly observed in ZnP(n)V (n=4,6,8). The MFEs on photocurrents increase with magnetic field for lower magnetic fields (B ≤200 mT) and are constant for higher magnetic fields (B > 200 mT). The magnitude of the MFEs in ZnP(n)V (n=6,8) are larger than that in ZnP(4)V. The MFEs can be explained by radical pair mechanism. The magnitude of the MFEs is larger than those in electrodes modified with ZnP(n)V (n=4,6,8) as Langmuir-Blodgett films. The results are most likely attributable to the properties of [BMIM][BF4] and the mechanism of photoelectrochemical reaction.

  5. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  6. Polymerase chain reaction system using magnetic beads for analyzing a sample that includes nucleic acid

    Science.gov (United States)

    Nasarabadi, Shanavaz [Livermore, CA

    2011-01-11

    A polymerase chain reaction system for analyzing a sample containing nucleic acid includes providing magnetic beads; providing a flow channel having a polymerase chain reaction chamber, a pre polymerase chain reaction magnet position adjacent the polymerase chain reaction chamber, and a post pre polymerase magnet position adjacent the polymerase chain reaction chamber. The nucleic acid is bound to the magnetic beads. The magnetic beads with the nucleic acid flow to the pre polymerase chain reaction magnet position in the flow channel. The magnetic beads and the nucleic acid are washed with ethanol. The nucleic acid in the polymerase chain reaction chamber is amplified. The magnetic beads and the nucleic acid are separated into a waste stream containing the magnetic beads and a post polymerase chain reaction mix containing the nucleic acid. The reaction mix containing the nucleic acid flows to an analysis unit in the channel for analysis.

  7. Sensitized charge carrier injection into organic crystals studied by isotope effects in weak magnetic fields

    International Nuclear Information System (INIS)

    Bube, W.; Michel-Beyerle, M.E.; Haberkorn, R.; Steffens, E.

    1977-01-01

    The magnetic field (H approximately 50 Oe) dependence of the rhodamine sensitized triplet exciton density in anthracene crystals is influenced by isotopic substitution. This confirms the hyperfine interaction as mechanism explaining the change of the spin multiplicity in the initially formed singlet state of the radical pair. The isotope effect occurs in the sensitizing dye ( 14 N/ 15 N) rather than at the molecular site of the injected charge within the crystal. This can be understood in terms of the high hopping frequency of the charge carriers as compared to the time constant of the hyperfine induced singlet-triplet transition. Since the dye molecules adsorb in an oriented fashion, the angular dependence of the magnetic field modulation of the triplet exciton density can be interpreted without assuming any additional interactions. (Auth.)

  8. Spin polarization and magnetic effects in radical reactions

    International Nuclear Information System (INIS)

    Salikhov, K.M.; Molin, Yu.N.; Sagdeev, R.Z.; Buchachenko, A.L.

    1984-01-01

    Studies on the effects of chemically induced dynamic nuclear and electron polarizations (CIDNP and CIDEP), and magnetic effects in radical reactions, have given rise to a new rapidly-progressing field of chemical physics. It came into being about ten years ago and has been attracting the ever-growing attention of researchers in related areas. The present book is a fairly all-embracing review of the state of affairs in this field. The book presents the physical background (both theoretical and experimental) of CIDNP and CIDEP, of the effects of an external magnetic field and magnetic nuclear moment (magnetic isotope effects) on radical reactions in solutions. Great attention has been paid to the application of chemical spin polarization and magnetic effects to solving various problems of chemical kinetics, structural chemistry, molecular physics, magnetobiology, and radiospectroscopy. The book will be useful for physicists, chemists and biologists employing CIDNP, CIDEP and magnetic effects in their investigations, as well as for researchers in related fields of chemical physics. The book can be also recommended for postgraduates and senior undergraduate students. (Auth.)

  9. Estimation of parameter sensitivities for stochastic reaction networks

    KAUST Repository

    Gupta, Ankit

    2016-01-07

    Quantification of the effects of parameter uncertainty is an important and challenging problem in Systems Biology. We consider this problem in the context of stochastic models of biochemical reaction networks where the dynamics is described as a continuous-time Markov chain whose states represent the molecular counts of various species. For such models, effects of parameter uncertainty are often quantified by estimating the infinitesimal sensitivities of some observables with respect to model parameters. The aim of this talk is to present a holistic approach towards this problem of estimating parameter sensitivities for stochastic reaction networks. Our approach is based on a generic formula which allows us to construct efficient estimators for parameter sensitivity using simulations of the underlying model. We will discuss how novel simulation techniques, such as tau-leaping approximations, multi-level methods etc. can be easily integrated with our approach and how one can deal with stiff reaction networks where reactions span multiple time-scales. We will demonstrate the efficiency and applicability of our approach using many examples from the biological literature.

  10. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    Magnetic resonance is a very powerful methodology that has been employed successfully in many applications for about 70 years now, resulting in a wealth of scientific, technological, and diagnostic data. Despite its many advantages, one major drawback of magnetic resonance is its relatively poor sensitivity and, as a consequence, its bad spatial resolution when examining heterogeneous samples. Contemporary science and technology often make use of very small amounts of material and examine heterogeneity on a very small length scale, both of which are well beyond the current capabilities of conventional magnetic resonance. It is therefore very important to significantly improve both the sensitivity and the spatial resolution of magnetic resonance techniques. The quest for higher sensitivity led in recent years to the development of many alternative detection techniques that seem to rival and challenge the conventional ;old-fashioned; induction-detection approach. The aim of this manuscript is to briefly review recent advances in the field, and to provide a quantitative as well as qualitative comparison between various detection methods with an eye to future potential advances and developments. We first offer a common definition of sensitivity in magnetic resonance to enable proper quantitative comparisons between various detection methods. Following that, up-to-date information about the sensitivity capabilities of the leading recently-developed detection approaches in magnetic resonance is provided, accompanied by a critical comparison between them and induction detection. Our conclusion from this comparison is that induction detection is still indispensable, and as such, it is very important to look for ways to significantly improve it. To do so, we provide expressions for the sensitivity of induction-detection, derived from both classical and quantum mechanics, that identify its main limiting factors. Examples from current literature, as well as a description of

  11. A comparison of the sensitivities of detection of Plasmodium falciparum gametocytes by magnetic fractionation, thick blood film microscopy, and RT-PCR

    Directory of Open Access Journals (Sweden)

    St-Pierre Tim G

    2009-05-01

    Full Text Available Abstract Background The magnetic properties of Plasmodium-infected erythrocytes have been exploited for different clinical and research purposes. A recent study in a rural clinical setting in Papua New Guinea has demonstrated that Plasmodium falciparum gametocyte detection is facilitated by magnetic deposition microscopy but no study has yet determined the relative sensitivity and limit of detection of a magnetic fractionation technique. The present study compares the detection limit and sensitivity of a technique based on the use of commercially available magnetic fractionation columns with those for thick blood film microscopy and reverse transcriptase polymerase chain reaction (RT-PCR methods. Methods Gametocyte detection in six series of dilutions of cultured P. falciparum parasites with known gametocytaemia was conducted using magnetic fractionation, thick blood film, and RT-PCR techniques. Results The preparations obtained by the magnetic fractionation method were of thin film quality allowing easy gametocyte identification by light microscopy. Magnetic fractionation had a higher sensitivity and approximately two orders of magnitude better limit of detection than thick blood film microscopy. Gametocytes were also more readily detectable on the magnetically fractionated preparations. Magnetic fractionation had a similar limit of detection to that of RT-PCR. Conclusion Magnetic fractionation is a highly sensitive and convenient method for gametocyte detection in comparison with the standard thick blood film and RT-PCR methods, and could readily be adapted to field application.

  12. Magnetic field assisted Fenton reactions for the enhanced degradation of methyl blue

    Institute of Scientific and Technical Information of China (English)

    Xiao Long Hao; Lu Yi Zou; Guang Sheng Zhang; Yi Bo Zhang

    2009-01-01

    Magnetic field was tentatively introduced into Fenton reactions system for the degradation and discoloration of methyl blue as the represent of organic chemical dye, which was a bio-refractory organic pollutant in industry wastewater. It was found that under optimal Fenton reaction conditions, with the assistant of magnetic field in Fenton reactions, the degradation rate of methyl blue, the decomposition rate of H2O2 and the conversion rate of Fe2+ were accelerated, the extent of them would be improved by the increase of magnetic field intensity. Meanwhile, the mineralization of methyl blue (CODcr) was improved by over 10% with magnetic fiold.

  13. Mechanisms explaining Coulomb's electric force & Lorentz's magnetic force from a classical perspective

    Science.gov (United States)

    Correnti, Dan S.

    2018-06-01

    The underlying mechanisms of the fundamental electric and magnetic forces are not clear in current models; they are mainly mathematical constructs. This study examines the underlying physics from a classical viewpoint to explain Coulomb's electric force and Lorentz's magnetic force. This is accomplished by building upon already established physics. Although no new physics is introduced, extension of existing models is made by close examination. We all know that an electron carries a bound cylindrical B-field (CBF) as it translates. Here, we show how the electron CBF plays an intrinsic role in the generation of the electric and magnetic forces.

  14. Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

    International Nuclear Information System (INIS)

    Hwang, S. M.; Yu, K. K.; Lee, Y. H.; Kang, C. S.; Kim, K.; Lee, S. J.

    2013-01-01

    For sensitive measurements of micro-Tesla nuclear magnetic resonance (μT-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 fT√ Hz, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise μT-NMR experiments.

  15. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  16. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study.

    Science.gov (United States)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan; Dirksen, Asger; Elberling, Jesper

    2011-06-01

    Multiple chemical sensitivity (MCS) is characterised by adverse effects due to exposure to low levels of chemical substances. The aetiology is unknown, but chemical related respiratory symptoms have been found associated with positive patch test. The purpose of this study was to investigate the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical sensitivity. Associations were controlled for the possible confounding effects of sex, age, asthma, eczema, atopic dermatitis, psychological and social factors, and smoking habits. In unadjusted analyses we found associations between allergic and non-allergic cutaneous reactions on patch testing and the two most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0.006). Our results suggest that individuals with self-reported chemical sensitivity show increased non-allergic cutaneous reactions based on day 2 readings of patch tests. Copyright © 2011 Elsevier GmbH. All rights reserved.

  17. Effect of magnetic field on the zero valent iron induced oxidation reaction

    International Nuclear Information System (INIS)

    Kim, Dong-hyo; Kim, Jungwon; Choi, Wonyong

    2011-01-01

    Highlights: → We investigate the zero valent iron induced oxidation in the presence of magnetic field. → The oxidative degradation of 4-chlorophenol is enhanced by the magnetic field. → ESR measurement confirms that more OH radicals are generated in the presence of magnetic field. → The magnetic field affects the mass transfer of O 2 and the recombination of radicals. - Abstract: The magnetic field (MF) effect on the zero valent iron (ZVI) induced oxidative reaction was investigated for the first time. The degradation of 4-chlorophenol (4-CP) in the ZVI system was employed as the test oxidative reaction. MF markedly enhanced the degradation of 4-CP with the concurrent production of chlorides. The consumption of dissolved O 2 by ZVI reaction was also enhanced in the presence of MF whereas the competing reaction of H 2 production from proton reduction was retarded. Since the ZVI-induced oxidation is mainly driven by the in situ generated hydroxyl radicals, the production of OH radicals was monitored by the spin trap method using electron spin resonance (ESR) spectroscopy. It was confirmed that the concentration of trapped OH radicals was enhanced in the presence of MF. Since both O 2 and Fe 0 are paramagnetic, the diffusion of O 2 onto the iron surface might be accelerated under MF. The magnetized iron can attract oxygen on itself, which makes the mass transfer process faster. As a result, the surface electrochemical reaction between Fe 0 and O 2 can be accelerated with the enhanced production of OH radicals. MF might retard the recombination of OH radicals as well.

  18. Improving sensitivity to magnetic fields and electric dipole moments by using measurements of individual magnetic sublevels

    Science.gov (United States)

    Tang, Cheng; Zhang, Teng; Weiss, David S.

    2018-03-01

    We explore ways to use the ability to measure the populations of individual magnetic sublevels to improve the sensitivity of magnetic field measurements and measurements of atomic electric dipole moments (EDMs). When atoms are initialized in the m =0 magnetic sublevel, the shot-noise-limited uncertainty of these measurements is 1 /√{2 F (F +1 ) } smaller than that of a Larmor precession measurement. When the populations in the even (or odd) magnetic sublevels are combined, we show that these measurements are independent of the tensor Stark shift and the second order Zeeman shift. We discuss the complicating effect of a transverse magnetic field and show that when the ratio of the tensor Stark shift to the transverse magnetic field is sufficiently large, an EDM measurement with atoms initialized in the superposition of the stretched states can reach the optimal sensitivity.

  19. Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

    Energy Technology Data Exchange (ETDEWEB)

    Ranjbaran, M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Tehranchi, M.M., E-mail: teranchi@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Physics Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Hamidi, S.M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Khalkhali, S.M.H. [Physics Department, Kharazmi University, Tehran (Iran, Islamic Republic of)

    2017-02-15

    Highly sensitive atomic magnetometers use optically detected magnetic resonance of atomic spins to measure extremely weak magnetic field changes. The magnetometer sensitivity is directly proportional to the ratio of intensity to line-shape of the resonance signal. To obtain narrower resonance signal, we implemented harmonic detection of magnetic resonance method in M{sub x} configuration. The nonlinear spin polarization dynamics in detection of the higher harmonics were employed in phenomenological Bloch equations. The measured and simulated harmonic components of the resonance signals in frequency domain yielded significantly narrower line-width accompanying much improved sensitivity. Our results confirm the sensitivity improvement by a factor of two in optical atomic magnetometer via second harmonic signal which can open a new insight in the weak magnetic field measurement system design. - Highlights: • Highly sensitive atomic magnetometers have been used to measure weak magentic filed. • To obtain narrower resonance signal, we impalnted harmonic detection of magnetic resonance. • The nonlinear spin polarization dynamics in detetion of the higher harmonics were imployed.

  20. Ultra-high sensitivity moment magnetometry of geological samples using magnetic microscopy

    Science.gov (United States)

    Lima, Eduardo A.; Weiss, Benjamin P.

    2016-09-01

    Useful paleomagnetic information is expected to be recorded by samples with moments up to three orders of magnitude below the detection limit of standard superconducting rock magnetometers. Such samples are now detectable using recently developed magnetic microscopes, which map the magnetic fields above room-temperature samples with unprecedented spatial resolutions and field sensitivities. However, realizing this potential requires the development of techniques for retrieving sample moments from magnetic microscopy data. With this goal, we developed a technique for uniquely obtaining the net magnetic moment of geological samples from magnetic microscopy maps of unresolved or nearly unresolved magnetization. This technique is particularly powerful for analyzing small, weakly magnetized samples such as meteoritic chondrules and terrestrial silicate crystals like zircons. We validated this technique by applying it to field maps generated from synthetic sources and also to field maps measured using a superconducting quantum interference device (SQUID) microscope above geological samples with moments down to 10-15 Am2. For the most magnetic rock samples, the net moments estimated from the SQUID microscope data are within error of independent moment measurements acquired using lower sensitivity standard rock magnetometers. In addition to its superior moment sensitivity, SQUID microscope net moment magnetometry also enables the identification and isolation of magnetic contamination and background sources, which is critical for improving accuracy in paleomagnetic studies of weakly magnetic samples.

  1. Iron oxide nanoparticle-micelles (ION-micelles for sensitive (molecular magnetic particle imaging and magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Lucas W E Starmans

    Full Text Available BACKGROUND: Iron oxide nanoparticles (IONs are a promising nanoplatform for contrast-enhanced MRI. Recently, magnetic particle imaging (MPI was introduced as a new imaging modality, which is able to directly visualize magnetic particles and could serve as a more sensitive and quantitative alternative to MRI. However, MPI requires magnetic particles with specific magnetic properties for optimal use. Current commercially available iron oxide formulations perform suboptimal in MPI, which is triggering research into optimized synthesis strategies. Most synthesis procedures aim at size control of iron oxide nanoparticles rather than control over the magnetic properties. In this study, we report on the synthesis, characterization and application of a novel ION platform for sensitive MPI and MRI. METHODS AND RESULTS: IONs were synthesized using a thermal-decomposition method and subsequently phase-transferred by encapsulation into lipidic micelles (ION-Micelles. Next, the material and magnetic properties of the ION-Micelles were analyzed. Most notably, vibrating sample magnetometry measurements showed that the effective magnetic core size of the IONs is 16 nm. In addition, magnetic particle spectrometry (MPS measurements were performed. MPS is essentially zero-dimensional MPI and therefore allows to probe the potential of iron oxide formulations for MPI. ION-Micelles induced up to 200 times higher signal in MPS measurements than commercially available iron oxide formulations (Endorem, Resovist and Sinerem and thus likely allow for significantly more sensitive MPI. In addition, the potential of the ION-Micelle platform for molecular MPI and MRI was showcased by MPS and MRI measurements of fibrin-binding peptide functionalized ION-Micelles (FibPep-ION-Micelles bound to blood clots. CONCLUSIONS: The presented data underlines the potential of the ION-Micelle nanoplatform for sensitive (molecular MPI and warrants further investigation of the Fib

  2. Explaining competitive reaction effects

    NARCIS (Netherlands)

    Leeflang, P.S.H.; Wittink, D.R.

    Changes in promotional expenditure decisions for a brand, as in other marketing decisions, should be based on the expected impact on purchase and consumption behavior as well as on the likely reactions by competitors. Purchase behavior may be predicted from estimated demand functions. Competitive

  3. Spin-torque diode with tunable sensitivity and bandwidth by out-of-plane magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Li, X.; Zheng, C.; Pong, Philip W. T. [Department of Electrical and Electronic Engineering, The University of Hong Kong (Hong Kong); Zhou, Y., E-mail: yanzhou@hku.hk [School of Electronics Science and Engineering, Nanjing University, Nanjing 210093 (China); Department of Physics, The University of Hong Kong (Hong Kong); Kubota, H.; Yuasa, S. [Spintronics Research Center, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8568 (Japan)

    2016-06-06

    Spin-torque diodes based on nanosized magnetic tunnel junctions are novel microwave detectors with high sensitivity and wide frequency bandwidth. While previous reports mainly focus on improving the sensitivity, the approaches to extend the bandwidth are limited. This work experimentally demonstrates that through optimizing the orientation of the external magnetic field, wide bandwidth can be achieved while maintaining high sensitivity. The mechanism of the frequency- and sensitivity-tuning is investigated through analyzing the dependence of resonant frequency and DC voltage on the magnitude and the tilt angle of hard-plane magnetic field. The frequency dependence is qualitatively explicated by Kittel's ferromagnetic resonance model. The asymmetric resonant frequency at positive and negative magnetic field is verified by the numerical simulation considering the in-plane anisotropy. The DC voltage dependence is interpreted through evaluating the misalignment angle between the magnetization of the free layer and the reference layer. The tunability of the detector performance by the magnetic field angle is evaluated through characterizing the sensitivity and bandwidth under 3D magnetic field. The frequency bandwidth up to 9.8 GHz or maximum sensitivity up to 154 mV/mW (after impedance mismatch correction) can be achieved by tuning the angle of the applied magnetic field. The results show that the bandwidth and sensitivity can be controlled and adjusted through optimizing the orientation of the magnetic field for various applications and requirements.

  4. Teaching Using Immersion - Explaining Magnetism and Eclipses in a Planetarium Dome

    Science.gov (United States)

    Reiff, P. H.; Sumners, C.

    2017-12-01

    Previously we have shown that three-dimensional concepts are more readily learned in a three-dimensional context. Although VR headsets are growing in popularity, they only provide a quite limited field of view, and each person in a group may be viewing a different direction or a different time in the visualization. By using instead a fullsphere movie (VR360) in a planetarium dome instead of a headset, you can share the VR and specify which half of the sphere your audience is looking at. You can pause the movie, ask questions using a clicker system, display the results, and move on if the subject is mastered or explain if items are not understood. In this paper we have used a planetarium dome in its more traditional "hemisphere" mode to teach about magnetism (using our new show "Magnetism - Defending Our Planet, Defining the Cosmos" ) and pre/post testing to show how many concepts can be understood in a relatively short experience. We have identified 35 concepts that most high school students do NOT know about magnetism, and have done pre/post testing on students and teachers. Most students more than doubled the number of concepts that they were able to explain after watching the show just one time. We have also created a series of eclipse animations to teach about solar and lunar eclipses. These animations have been used in more than 500 planetarium theaters and used as part of several TV specials on the August 2017 eclipse. By teaching eclipses in a dome, the students correctly understand the three-dimensional geometry of the Earth and Moon orbits and the causes of eclipses.

  5. Neutrino magnetic moment contribution to the neutrino-deuteron reaction

    International Nuclear Information System (INIS)

    Tsuji, K.; Nakamura, S.; Sato, T.; Kubodera, K.; Myhrer, F.

    2004-01-01

    We study the effect of the neutrino magnetic moment on the neutrino-deuteron breakup reaction, using a method called the standard nuclear physics approach, which has already been well tested for several electroweak processes involving the deuteron

  6. Self-Biased 215MHz Magnetoelectric NEMS Resonator for Ultra-Sensitive DC Magnetic Field Detection

    Science.gov (United States)

    Nan, Tianxiang; Hui, Yu; Rinaldi, Matteo; Sun, Nian X.

    2013-06-01

    High sensitivity magnetoelectric sensors with their electromechanical resonance frequencies electromechanical systems (NEMS) resonator with an electromechanical resonance frequency of 215 MHz based on an AlN/(FeGaB/Al2O3) × 10 magnetoelectric heterostructure for detecting DC magnetic fields. This magnetoelectric NEMS resonator showed a high quality factor of 735, and strong magnetoelectric coupling with a large voltage tunable sensitivity. The admittance of the magnetoelectric NEMS resonator was very sensitive to DC magnetic fields at its electromechanical resonance, which led to a new detection mechanism for ultra-sensitive self-biased RF NEMS magnetoelectric sensor with a low limit of detection of DC magnetic fields of ~300 picoTelsa. The magnetic/piezoelectric heterostructure based RF NEMS magnetoelectric sensor is compact, power efficient and readily integrated with CMOS technology, which represents a new class of ultra-sensitive magnetometers for DC and low frequency AC magnetic fields.

  7. Sensitive element of multifunctional sensor for measuring temperature, strain and magnetic field induction

    Directory of Open Access Journals (Sweden)

    Druzhinin A. A.

    2017-12-01

    Full Text Available Sensitive element of multifunctional sensor for measuring temperature, strain and magnetic field induction has been developed based on the studies of electrical conductivity and magnetoresistance of silicon and germanium microcrystals in the temperature range 4.2—70 K, strain ±1.5*10–3 rel.un. and magnetic fields of 0—14 T. The feature of the sensitive element is the using of the p- and n-type conductivity germanium microcrystals as mechanical and magnetic field sensors, respectively, and the p-type silicon microcrystal — as temperature sensor. That allows providing the compensation of temperature influence on piezoresistance and on sensitivity to the magnetic field.

  8. Differential Search Coils Based Magnetometers: Conditioning, Magnetic Sensitivity, Spatial Resolution

    Directory of Open Access Journals (Sweden)

    Timofeeva Maria

    2012-03-01

    Full Text Available A theoretical and experimental comparison of optimized search coils based magnetometers, operating either in the Flux mode or in the classical Lenz-Faraday mode, is presented. The improvements provided by the Flux mode in terms of bandwidth and measuring range of the sensor are detailed. Theory, SPICE model and measurements are in good agreement. The spatial resolution of the sensor is studied which is an important parameter for applications in non destructive evaluation. A general expression of the magnetic sensitivity of search coils sensors is derived. Solutions are proposed to design magnetometers with reduced weight and volume without degrading the magnetic sensitivity. An original differential search coil based magnetometer, made of coupled coils, operating in flux mode and connected to a differential transimpedance amplifier is proposed. It is shown that this structure is better in terms of volume occupancy than magnetometers using two separated coils without any degradation in magnetic sensitivity. Experimental results are in good agreement with calculations.

  9. Reaction pathway towards formation of cobalt single chain magnets and nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, G.; Desilva, Rohini M.; Palshin, V. [Center for Advanced Microstructures and Devices, Louisiana State University, 6980 Jefferson Highway, Baton Rouge, LA 70806 (United States); Desilva, N. [Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803 (United States); Palmer, G. [Department of Biochemistry and Cell Biology, Rice University, MS 140, 6100 Main street, Houston, TX 77251 (United States); Kumar, Challa S.S.R., E-mail: ckumar1@lsu.ed [Center for Advanced Microstructures and Devices, Louisiana State University, 6980 Jefferson Highway, Baton Rouge, LA 70806 (United States)

    2010-03-15

    With the advent of molecular magnets the quest for suitable high density magnetic storage materials has fuelled further research in this area. Here in this report, we present a detailed mechanistic investigation of thermal decomposition of cyclopentadienyl cobalt [CoCp(CO){sub 2}] precursor where Cp is the cyclopentadienyl moiety. The reaction revealed the formation of cobalt nanoparticles (Co-NPs) through an isolable reaction intermediate characterized as a Single Chain Magnet (SCM), [Co(Cp){sub 2}]{sub 2}CoCl{sub 4} (1). The SQUID magnetic measurements showed the presence of very strong antiferromagnetic interactions between Co{sup 2+} ions. The zero-field cooled (ZFC) and field cooled (FC) magnetization curves branch out below 5 K and there is evidence for frequency dependent complex susceptibility along with a maximum observed around 2.5 K. The optical studies indicated that the Co{sup 2+} d-d transition is influenced by the polarity of the solvents. The cobalt nanoparticles (Co-NPs) were obtained, either directly from 1 or from its precursor. They are spherical in shape with a mean size 15 nm, have fcc crystal structure and were found to be ferromagnetic at room temperature.

  10. Anomalous magneto-structural behavior of MnBi explained: A path towards an improved permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Zarkevich, N. A., E-mail: zarkev@ameslab.gov; Wang, L.-L. [The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011 (United States); Johnson, D. D. [The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011 (United States); Materials Science and Engineering, Iowa State University, Ames, Iowa 50011 (United States)

    2014-03-01

    Low-temperature MnBi (hexagonal NiAs phase) exhibits anomalies in the lattice constants (a, c) and bulk elastic modulus (B) below 100 K, spin reorientation and magnetic susceptibility maximum near 90 K, and, importantly for high-temperature magnetic applications, an increasing coercivity (unique to MnBi) above 180  K. We calculate the total energy and magneto-anisotropy energy (MAE) versus (a, c) using DFT+U methods. We reproduce and explain all the above anomalies. We predict that coercivity and MAE increase due to increasing a, suggesting means to improve MnBi permanent magnets.

  11. Anomalous magneto-structural behavior of MnBi explained: A path towards an improved permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Zarkevich, NA; Wang, LL; Johnson, DD

    2014-03-01

    Low-temperature MnBi (hexagonal NiAs phase) exhibits anomalies in the lattice constants (a, c) and bulk elastic modulus (B) below 100 K, spin reorientation and magnetic susceptibility maximum near 90 K, and, importantly for high-temperature magnetic applications, an increasing coercivity (unique to MnBi) above 180 K. We calculate the total energy and magneto-anisotropy energy (MAE) versus (a, c) using DFT+U methods. We reproduce and explain all the above anomalies. We predict that coercivity and MAE increase due to increasing a, suggesting means to improve MnBi permanent magnets. (C) 2014 Author(s).

  12. New magnetic materials obtained by ion-exchange reactions from non-magnetic layered perovskites

    International Nuclear Information System (INIS)

    Kageyama, H; Viciu, L; Caruntu, G; Ueda, Y; Wiley, J B

    2004-01-01

    New layered magnetic materials (MCl)Ca 2 Ta 3 O 10 (M = Cu, Fe), have been prepared by ion-exchange reactions of non-magnetic perovskite derivatives, ACa 2 Ta 3 O 10 (A = Rb, Li), in corresponding anhydrous molten salts. Powder x-ray diffraction patterns of the products are successfully indexed assuming tetragonal symmetry with cell dimensions a = 3.829 A and c = 15.533 A for Cu, and a = 3.822 A and c = 15.672 A for Fe. Being separated by the Ca 2 Ta 3 O 10 triple-layer perovskite slabs, the transition-metal chloride (MCl) network provides a two-dimensional magnetic lattice. Magnetic susceptibility measurements show that (CuCl)Ca 2 Ta 3 O 10 is in an antiferromagnetic state below 8 K, while (FeCl)Ca 2 Ta 3 O 10 has two anomalies at 91 and 125 K, suggesting successive phase transitions due to geometrical spin frustration

  13. B1 -sensitivity analysis of quantitative magnetization transfer imaging.

    Science.gov (United States)

    Boudreau, Mathieu; Stikov, Nikola; Pike, G Bruce

    2018-01-01

    To evaluate the sensitivity of quantitative magnetization transfer (qMT) fitted parameters to B 1 inaccuracies, focusing on the difference between two categories of T 1 mapping techniques: B 1 -independent and B 1 -dependent. The B 1 -sensitivity of qMT was investigated and compared using two T 1 measurement methods: inversion recovery (IR) (B 1 -independent) and variable flip angle (VFA), B 1 -dependent). The study was separated into four stages: 1) numerical simulations, 2) sensitivity analysis of the Z-spectra, 3) healthy subjects at 3T, and 4) comparison using three different B 1 imaging techniques. For typical B 1 variations in the brain at 3T (±30%), the simulations resulted in errors of the pool-size ratio (F) ranging from -3% to 7% for VFA, and -40% to > 100% for IR, agreeing with the Z-spectra sensitivity analysis. In healthy subjects, pooled whole-brain Pearson correlation coefficients for F (comparing measured double angle and nominal flip angle B 1 maps) were ρ = 0.97/0.81 for VFA/IR. This work describes the B 1 -sensitivity characteristics of qMT, demonstrating that it varies substantially on the B 1 -dependency of the T 1 mapping method. Particularly, the pool-size ratio is more robust against B 1 inaccuracies if VFA T 1 mapping is used, so much so that B 1 mapping could be omitted without substantially biasing F. Magn Reson Med 79:276-285, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Facilitating High School Students' Use of Multiple Representations to Describe and Explain Simple Chemical Reactions

    Science.gov (United States)

    Chandrasegaran, A. L.; Treagust, David F.; Mocerino, Mauro

    2011-01-01

    This study involved the evaluation of the efficacy of a planned instructional program to facilitate understanding of the macroscopic, submicroscopic and symbolic representational systems when describing and explaining chemical reactions by sixty-five Grade 9 students in a Singapore secondary school. A two-tier multiple-choice diagnostic instrument…

  15. An offset-trimmable array of magnetic-field-sensitive MOS transistors (MAGFETs)

    DEFF Research Database (Denmark)

    Ning, Feng; Bruun, Erik

    1997-01-01

    Magnetic-field sensors can be implemented by the use of a magnetic-field-sensitive MOSFET structure, commonly referred to as a MAGFET. The MAGFET is a split-drain MOSFET where the difference between the drain currents is dependent on the magnetic field applied to the MAGFET. Unfortunately, the se...

  16. Parametric sensitivity analysis for biochemical reaction networks based on pathwise information theory.

    Science.gov (United States)

    Pantazis, Yannis; Katsoulakis, Markos A; Vlachos, Dionisios G

    2013-10-22

    Stochastic modeling and simulation provide powerful predictive methods for the intrinsic understanding of fundamental mechanisms in complex biochemical networks. Typically, such mathematical models involve networks of coupled jump stochastic processes with a large number of parameters that need to be suitably calibrated against experimental data. In this direction, the parameter sensitivity analysis of reaction networks is an essential mathematical and computational tool, yielding information regarding the robustness and the identifiability of model parameters. However, existing sensitivity analysis approaches such as variants of the finite difference method can have an overwhelming computational cost in models with a high-dimensional parameter space. We develop a sensitivity analysis methodology suitable for complex stochastic reaction networks with a large number of parameters. The proposed approach is based on Information Theory methods and relies on the quantification of information loss due to parameter perturbations between time-series distributions. For this reason, we need to work on path-space, i.e., the set consisting of all stochastic trajectories, hence the proposed approach is referred to as "pathwise". The pathwise sensitivity analysis method is realized by employing the rigorously-derived Relative Entropy Rate, which is directly computable from the propensity functions. A key aspect of the method is that an associated pathwise Fisher Information Matrix (FIM) is defined, which in turn constitutes a gradient-free approach to quantifying parameter sensitivities. The structure of the FIM turns out to be block-diagonal, revealing hidden parameter dependencies and sensitivities in reaction networks. As a gradient-free method, the proposed sensitivity analysis provides a significant advantage when dealing with complex stochastic systems with a large number of parameters. In addition, the knowledge of the structure of the FIM can allow to efficiently address

  17. Two-dimensional magnetic sensitivity to asymmetric and symmetric deviations for SSC quadrupole magnets

    International Nuclear Information System (INIS)

    Xu, M.; Waynert, J.A.

    1994-01-01

    The magnetic multipole sensitivity to asymmetric and symmetric deviations is analyzed in the two-dimensional cross-section of SSC quadrupole magnets. Deviations in the 2D cross-section caused by variations in the superconducting cable locations due to changes in the thickness of the pole sheet, mid plane insulation, inter-layer spacer, backing sheet, and copper wedges have direct impact on the magnetic field gradient and multipoles in the straight section of the magnets. Asymmetric deviations due to different coil sizes in a cross-section are also analyzed. The analyses are performed mainly with the software package AHARM. SSCMAG and finite element software PE2D were also used to obtain baselines and to verify the results. The results provide information essential to an understanding of the deviations of the multipoles resulting from manufacturing processes, and suggest possibilities for tuning the multipoles to meet the magnetic requirements

  18. Understanding fuel magnetization and mix using secondary nuclear reactions in magneto-inertial fusion.

    Science.gov (United States)

    Schmit, P F; Knapp, P F; Hansen, S B; Gomez, M R; Hahn, K D; Sinars, D B; Peterson, K J; Slutz, S A; Sefkow, A B; Awe, T J; Harding, E; Jennings, C A; Chandler, G A; Cooper, G W; Cuneo, M E; Geissel, M; Harvey-Thompson, A J; Herrmann, M C; Hess, M H; Johns, O; Lamppa, D C; Martin, M R; McBride, R D; Porter, J L; Robertson, G K; Rochau, G A; Rovang, D C; Ruiz, C L; Savage, M E; Smith, I C; Stygar, W A; Vesey, R A

    2014-10-10

    Magnetizing the fuel in inertial confinement fusion relaxes ignition requirements by reducing thermal conductivity and changing the physics of burn product confinement. Diagnosing the level of fuel magnetization during burn is critical to understanding target performance in magneto-inertial fusion (MIF) implosions. In pure deuterium fusion plasma, 1.01 MeV tritons are emitted during deuterium-deuterium fusion and can undergo secondary deuterium-tritium reactions before exiting the fuel. Increasing the fuel magnetization elongates the path lengths through the fuel of some of the tritons, enhancing their probability of reaction. Based on this feature, a method to diagnose fuel magnetization using the ratio of overall deuterium-tritium to deuterium-deuterium neutron yields is developed. Analysis of anisotropies in the secondary neutron energy spectra further constrain the measurement. Secondary reactions also are shown to provide an upper bound for the volumetric fuel-pusher mix in MIF. The analysis is applied to recent MIF experiments [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z Pulsed Power Facility, indicating that significant magnetic confinement of charged burn products was achieved and suggesting a relatively low-mix environment. Both of these are essential features of future ignition-scale MIF designs.

  19. Evaluation of parameter sensitivities for flux-switching permanent magnet machines based on simplified equivalent magnetic circuit

    Directory of Open Access Journals (Sweden)

    Gan Zhang

    2017-05-01

    Full Text Available Most of the published papers regarding the design of flux-switching permanent magnet machines are focused on the analysis and optimization of electromagnetic or mechanical behaviors, however, the evaluate of the parameter sensitivities have not been covered, which contrarily, is the main contribution of this paper. Based on the finite element analysis (FEA and simplified equivalent magnetic circuit, the method proposed in this paper enables the influences of parameters on the electromagnetic performances, i.e. the parameter sensitivities, to be given by equations. The FEA results are also validated by experimental measurements.

  20. How sensitizing is chlorocresol?

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Hamann, K

    1984-01-01

    Chlorocresol is a biocide with widespread use in industry and pharmaceutical products. It is an occasional human contact sensitizer. The sensitizing potential of chlorocresol was judged strong using the guinea pig maximization test (GPMT) and doubtful in the less sensitive open epicutaneous test......% in pet. showed 11 reactions among 1462 patients tested, but none were explainable and reproducible during re-tests and provocative use tests, indicating that the GPMT overestimated the sensitization potential. The results from guinea pig allergy tests cannot stand alone but have to be validated by other...

  1. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  2. Alignment of Carbon Nanotubes Comprising Magnetically Sensitive Metal Oxides in Nanofluids

    Science.gov (United States)

    Hong, Haiping (Inventor); Peterson, G. P. " Bud" (Inventor)

    2016-01-01

    The present invention is a nanoparticle mixture or suspension or nanofluid comprising nonmagnetically sensitive nanoparticles, magnetically sensitive nanoparticles, and surfactant(s). The present invention also relates to methods of preparing and using the same.

  3. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Magnetic field effects on geminate reactions. Study of anthraquinone - hydrogen donors systems

    International Nuclear Information System (INIS)

    Vidal, Marie-Helene

    1987-01-01

    This study is devoted to magnetic field effects on chemical reactions which involve a radical pair with correlated spins (radical in a 'cage'). In the first part, the radical pair theory is described: mechanisms of singlet-triplet mixing, the different interactions inside the pair and a quantum mechanical treatment of the radical pair. The details of the experimental method (nanosecond laser flash photolysis) are reported in the second part. In the third part are shown experimental results obtained on Anthraquinone (AQ) - Hydrogen donors systems: - There is no magnetic field effect in homogeneous solution even at a high viscosity. The absorption spectra of the different reaction intermediates are obtained. - However a magnetic field effect is put forward when AQ is introduced in SDS micelles which are hydrogen donors. The absorption spectrum of the AQH · . semi-quinone radical in 'cage' is shown and a mechanism is proposed for its disappearance to generate the AQH-S and AQH 2 species. - The addition of 9, 10 Dihydroanthracene (DH2) inside the micelle near AQ induces an increase of the magnetic field effect by creation of (AQH · . - DH · . ) pairs which diffuse slowly. - Fixed radical pairs in a protein matrix were studied in reaction centers of photosynthetic bacteria: in that case, the half effect field is shifted to low fields when compared to the previously described systems. (author) [fr

  5. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  6. Palladium Loaded on Magnetic Nanoparticles as Efficient and Recyclable Catalyst for the Suzuki- Miyaura Reaction

    Directory of Open Access Journals (Sweden)

    H. Khojasteh

    2015-07-01

    Full Text Available Palladium is the best metal catalyst for Suzuki cross coupling reaction for synthesize of unsymmetrical biaryl compounds. But its high cost limits its application in wide scale. Using of nanoscale particles as active catalytic cites is a good approach for reducing needed noble metal. By loading precious nanoparticles on magnetic nanocores as a support, recycling and reusing of catalyst will be possible. Magnetic nanoparticles have super paramagnetic feature and applying an external magnetic field can collect the supported catalyst from reaction milieu simply. In this work new palladium catalyst immobilized on modified magnetic nanoparticles containing NNO donor atoms were synthesized. Then the catalyst characterized by FT-IR spectroscopy, thermogravimetric analysis, X-ray diffraction and ICP. Prepared catalyst showed high activity in the Suzuki– Miyaura cross-coupling reaction of phenylboronic acid with aryl halides. Activity, Pd loading, reusability and Pd leaching of catalyst were studied. Results showed that the supported catalyst has the advantage to be completely recoverable with the simple application of an external magnetic field.

  7. A comparison of approximation techniques for variance-based sensitivity analysis of biochemical reaction systems

    Directory of Open Access Journals (Sweden)

    Goutsias John

    2010-05-01

    Full Text Available Abstract Background Sensitivity analysis is an indispensable tool for the analysis of complex systems. In a recent paper, we have introduced a thermodynamically consistent variance-based sensitivity analysis approach for studying the robustness and fragility properties of biochemical reaction systems under uncertainty in the standard chemical potentials of the activated complexes of the reactions and the standard chemical potentials of the molecular species. In that approach, key sensitivity indices were estimated by Monte Carlo sampling, which is computationally very demanding and impractical for large biochemical reaction systems. Computationally efficient algorithms are needed to make variance-based sensitivity analysis applicable to realistic cellular networks, modeled by biochemical reaction systems that consist of a large number of reactions and molecular species. Results We present four techniques, derivative approximation (DA, polynomial approximation (PA, Gauss-Hermite integration (GHI, and orthonormal Hermite approximation (OHA, for analytically approximating the variance-based sensitivity indices associated with a biochemical reaction system. By using a well-known model of the mitogen-activated protein kinase signaling cascade as a case study, we numerically compare the approximation quality of these techniques against traditional Monte Carlo sampling. Our results indicate that, although DA is computationally the most attractive technique, special care should be exercised when using it for sensitivity analysis, since it may only be accurate at low levels of uncertainty. On the other hand, PA, GHI, and OHA are computationally more demanding than DA but can work well at high levels of uncertainty. GHI results in a slightly better accuracy than PA, but it is more difficult to implement. OHA produces the most accurate approximation results and can be implemented in a straightforward manner. It turns out that the computational cost of the

  8. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Scheffler, Klaus; Ehses, Philipp

    2017-01-01

    Purpose: Clinical use of magnetic resonance electrical impedance tomography (MREIT) still requires significant sensitivity improvements. Here, the measurement of the current-induced magnetic field (DBz,c) is improved using systematic efficiency analyses and optimization of multi-echo spin echo...... (MESE) and steady-state free precession free induction decay (SSFP-FID) sequences. Theory and Methods: Considering T1, T2, and T 2 relaxation in the signal-to-noise ratios (SNRs) of the MR magnitude images, the efficiency of MESE and SSFP-FID MREIT experiments, and its dependence on the sequence...

  9. Neurons are sensitive to the magnetic fields applied within the range of MR intensity used for diagnostic purposes

    International Nuclear Information System (INIS)

    Azanza, M.J.

    1997-01-01

    A very high number of data, obtained from molecular and cell biology experimental work, show that living beings are sensitive to either the static magnetic fields (SMF) or the electromagnetic fields in the extremely low frequency (ELF) range (1). Considering the question of the intensity range of the SMF applied for clinical diagnosis, we have made experiments by applying SMF (0,3-0,7 T) directly to neurons. We have shown that there exist a neuron magneto sensitivity explained as a result of the diamagnetism of the phospholipid and protein molecules of the lipid bilayer plasma membrane. This diamagnetism is working together with electric dipolar interactions (a mixed up interaction coined as super diamagnetism) and binded membrane Ca''2+ cooperative coulomb explosion, which in turn operate Ca''2+ -dependent-K''+ membrane channels (2,3). The specific intrinsic metabolic characteristics of the neurons populations explain two types of responses: either a variation in the firing frequency (increases or decreases) or a decrease in the spikes amplitude. This second effect is explained by the inhibition of the Na''+ -K''+-ATP-ase ionic pumps, inactivated by the same superdiamagnetims mechanism. We show in this paper the dependence of the frequency and amplitude changes, of the electrophysiological activity of the neurons, with the intensity of the applied SMF. (Author) 30 refs

  10. Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Tujin; Su, Dian; Liu, Tao; Tang, Keqi; Camp, David G.; Qian, Weijun; Smith, Richard D.

    2012-04-01

    Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

  11. Magnetic isotope and external magnetic field effects upon the photo-Fries rearrangement of 1-naphthyl acetate

    International Nuclear Information System (INIS)

    Nakagaki, R.; Hiramatsu, M.; Watanabe, T.; Tanimoto, Y.; Nagakura, S.

    1985-01-01

    The reaction mechanisms of the photo-Fries rearrangement of 1-naphthyl acetate has been studied by means of steady-state photolysis and laser flash photolysis. A radical pair consisting of the 1-naphthoxyl and acetyl radicals is concluded to be a reaction intermediate. The yield of an in-cage product (2-acetyl-1-naphthol) exhibits a positive external magnetic field effect for the ester labeled by magnetically active 13 C, but no effect for the normal 12 C ester. The magnetic field effect observed for the labeled ester is quantitatively or semiquantitatively explained in terms of the radical-pair mechanism by considering hyperfine coupling between magnetically active nuclei ( 1 H and 13 C) and an unpaired electron in the acetyl radical. The in-cage product is formed through the singlet radical pair. 26 references, 5 figures, 3 tables

  12. Astrophysical Nuclear Reaction Rates in the Dense Metallic Environments

    Science.gov (United States)

    Kilic, Ali Ihsan

    2017-09-01

    Nuclear reaction rates can be enhanced by many orders of magnitude in dense and relatively cold astrophysical plasmas such as in white dwarfs, brown dwarfs, and giant planets. Similar conditions are also present in supernova explosions where the ignition conditions are vital for cosmological models. White dwarfs are compact objects that have both extremely high interior densities and very strong local magnetic fields. For the first time, a new formula has been developed to explain cross section and reaction rate quantities for light elements that includes not only the nuclear component but also the material dependence, magnetic field, and crystal structure dependency in dense metallic environments. I will present the impact of the developed formula on the cross section and reaction rates for light elements. This could have possible technological applications in energy production using nuclear fusion reactions.

  13. A highly sensitive CMOS digital Hall sensor for low magnetic field applications.

    Science.gov (United States)

    Xu, Yue; Pan, Hong-Bin; He, Shu-Zhuan; Li, Li

    2012-01-01

    Integrated CMOS Hall sensors have been widely used to measure magnetic fields. However, they are difficult to work with in a low magnetic field environment due to their low sensitivity and large offset. This paper describes a highly sensitive digital Hall sensor fabricated in 0.18 μm high voltage CMOS technology for low field applications. The sensor consists of a switched cross-shaped Hall plate and a novel signal conditioner. It effectively eliminates offset and low frequency 1/f noise by applying a dynamic quadrature offset cancellation technique. The measured results show the optimal Hall plate achieves a high current related sensitivity of about 310 V/AT. The whole sensor has a remarkable ability to measure a minimum ± 2 mT magnetic field and output a digital Hall signal in a wide temperature range from -40 °C to 120 °C.

  14. Motion behaviour of magneto-sensitive elastomers controlled by an external magnetic field for sensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Volkova, T.I., E-mail: tatiana.volkova@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Böhm, V., E-mail: valter.boehm@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Kaufhold, T., E-mail: tobias.kaufhold@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Popp, J., E-mail: jana.popp@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Becker, F., E-mail: felix.becker@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany); Borin, D.Yu., E-mail: dmitry.borin@tu-dresden.de [Technische Universität Dresden, Magnetofluiddynamics, Measuring and Automation Technology, D-01062 Dresden (Germany); Stepanov, G.V., E-mail: gstepanov@mail.ru [State Institute of Chemistry and Technology of Organoelement Compounds, 105118 Moscow (Russian Federation); Zimmermann, K., E-mail: klaus.zimmermann@tu-ilmenau.de [Technische Universität Ilmenau, Faculty of Mechanical Engineering, Technical Mechanics Group, D-98693 Ilmenau (Germany)

    2017-06-01

    The development of sensor systems with a complex adaptive regulation of the operating sensitivity and behaviour is an actual scientific and technical challenge. Smart materials like magneto-sensitive elastomers (MSE) are seen as one potential solution for this problem, since their mechanical properties may be controlled by external magnetic fields. The present paper deals with the investigation of elastic and damping properties of MSE containing magnetically soft particles under the influence of a uniform magnetic field. Based on the measurement of the first eigenfrequency of free bending vibrations of a fixed beam, the effective Young's modulus is evaluated theoretically and also numerically using Finite Element Method. It is shown that this parameter, as well as the first eigenfrequency of the beam, increases monotonically with the magnitude of the applied magnetic field. The results are aimed to develop an acceleration sensor with adaptive magnetically controllable sensitivity range for the detection of external mechanical stimuli of the environment. - Highlights: • The motion behaviour of magneto-sensitive elastomers (MSE) with magnetically soft particles is investigated. • The first eigenfrequency of free bending vibrations of an MSE beam can be controlled by a uniform magnetic field. • Based on the experimental results, the effective Young's modulus of the system is evaluated theoretically and numerically. • The Young's modulus increases monotonically with the magnitude of the applied magnetic field. • The controlled mechanical compliance of MSE may be used for development of sensor systems with adaptive sensitivity range.

  15. Cationic polyelectrolyte functionalized magnetic particles assisted highly sensitive pathogens detection in combination with polymerase chain reaction and capillary electrophoresis.

    Science.gov (United States)

    Chen, Jia; Lin, Yuexin; Wang, Yu; Jia, Li

    2015-06-01

    Pathogenic bacteria cause significant morbidity and mortality to humans. There is a pressing need to establish a simple and reliable method to detect them. Herein, we show that magnetic particles (MPs) can be functionalized by poly(diallyl dimethylammonium chloride) (PDDA), and the particles (PDDA-MPs) can be utilized as adsorbents for capture of pathogenic bacteria from aqueous solution based on electrostatic interaction. The as-prepared PDDA-MPs were characterized by Fourier-transform infrared spectroscopy, zeta potential, vibrating sample magnetometry, X-ray diffraction spectrometry, scanning electron microscopy, and transmission electron microscopy. The adsorption equilibrium time can be achieved in 3min. According to the Langmuir adsorption isotherm, the maximum adsorption capacities for E. coli O157:H7 (Gram-negative bacteria) and L. monocytogenes (Gram-positive bacteria) were calculated to be 1.8×10(9) and 3.1×10(9)cfumg(-1), respectively. The bacteria in spiked mineral water (1000mL) can be completely captured when applying 50mg of PDDA-MPs and an adsorption time of 5min. In addition, PDDA-MPs-based magnetic separation method in combination with polymerase chain reaction and capillary electrophoresis allows for rapid detection of 10(1)cfumL(-1) bacteria. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Sub-millitesla magnetic field effects on the recombination reaction of flavin and ascorbic acid radicals

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Emrys W.; Henbest, Kevin B.; Timmel, Christiane R., E-mail: christiane.timmel@chem.ox.ac.uk, E-mail: stuart.mackenzie@chem.ox.ac.uk [Department of Chemistry, Centre for Advanced Electron Spin Resonance, University of Oxford, Oxford (United Kingdom); Kattnig, Daniel R.; Hore, P. J.; Mackenzie, Stuart R., E-mail: christiane.timmel@chem.ox.ac.uk, E-mail: stuart.mackenzie@chem.ox.ac.uk [Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, Oxford (United Kingdom)

    2016-08-28

    Even though the interaction of a <1 mT magnetic field with an electron spin is less than a millionth of the thermal energy at room temperature (k{sub B}T), it still can have a profound effect on the quantum yields of radical pair reactions. We present a study of the effects of sub-millitesla magnetic fields on the photoreaction of flavin mononucleotide with ascorbic acid. Direct control of the reaction pathway is achieved by varying the rate of electron transfer from ascorbic acid to the photo-excited flavin. At pH 7.0, we verify the theoretical prediction that, apart from a sign change, the form of the magnetic field effect is independent of the initial spin configuration of the radical pair. The data agree well with model calculations based on a Green’s function approach that allows multinuclear spin systems to be treated including the diffusive motion of the radicals, their spin-selective recombination reactions, and the effects of the inter-radical exchange interaction. The protonation states of the radicals are uniquely determined from the form of the magnetic field-dependence. At pH 3.0, the effects of two chemically distinct radical pair complexes combine to produce a pronounced response to ∼500 μT magnetic fields. These findings are relevant to the magnetic responses of cryptochromes (flavin-containing proteins proposed as magnetoreceptors in birds) and may aid the evaluation of effects of weak magnetic fields on other biologically relevant electron transfer processes.

  17. Sensitivity Enhancement in Magnetic Sensors Based on Ferroelectric-Bimorphs and Multiferroic Composites

    Directory of Open Access Journals (Sweden)

    Gollapudi Sreenivasulu

    2016-02-01

    Full Text Available Multiferroic composites with ferromagnetic and ferroelectric phases have been studied in recent years for use as sensors of AC and DC magnetic fields. Their operation is based on magneto-electric (ME coupling between the electric and magnetic subsystems and is mediated by mechanical strain. Such sensors for AC magnetic fields require a bias magnetic field to achieve pT-sensitivity. Novel magnetic sensors with a permanent magnet proof mass, either on a ferroelectric bimorph or a ferromagnetic-ferroelectric composite, are discussed. In both types, the interaction between the applied AC magnetic field and remnant magnetization of the magnet results in a mechanical strain and a voltage response in the ferroelectric. Our studies have been performed on sensors with a Nd-Fe-B permanent magnet proof mass on (i a bimorph of oppositely-poled lead zirconate titanate (PZT platelets and (ii a layered multiferroic composite of PZT-Metglas-Ni. The sensors have been characterized in terms of sensitivity and equivalent magnetic noise N. Noise N in both type of sensors is on the order of 200 pT/√Hz at 1 Hz, a factor of 10 improvement compared to multiferroic sensors without a proof mass. When the AC magnetic field is applied at the bending resonance for the bimorph, the measured N ≈ 700 pT/√Hz. We discuss models based on magneto-electro-mechanical coupling at low frequency and bending resonance in the sensors and theoretical estimates of ME voltage coefficients are in very good agreement with the data.

  18. Sensitivity Enhancement in Magnetic Sensors Based on Ferroelectric-Bimorphs and Multiferroic Composites.

    Science.gov (United States)

    Sreenivasulu, Gollapudi; Qu, Peng; Petrov, Vladimir; Qu, Hongwei; Srinivasan, Gopalan

    2016-02-20

    Multiferroic composites with ferromagnetic and ferroelectric phases have been studied in recent years for use as sensors of AC and DC magnetic fields. Their operation is based on magneto-electric (ME) coupling between the electric and magnetic subsystems and is mediated by mechanical strain. Such sensors for AC magnetic fields require a bias magnetic field to achieve pT-sensitivity. Novel magnetic sensors with a permanent magnet proof mass, either on a ferroelectric bimorph or a ferromagnetic-ferroelectric composite, are discussed. In both types, the interaction between the applied AC magnetic field and remnant magnetization of the magnet results in a mechanical strain and a voltage response in the ferroelectric. Our studies have been performed on sensors with a Nd-Fe-B permanent magnet proof mass on (i) a bimorph of oppositely-poled lead zirconate titanate (PZT) platelets and (ii) a layered multiferroic composite of PZT-Metglas-Ni. The sensors have been characterized in terms of sensitivity and equivalent magnetic noise N. Noise N in both type of sensors is on the order of 200 pT/√Hz at 1 Hz, a factor of 10 improvement compared to multiferroic sensors without a proof mass. When the AC magnetic field is applied at the bending resonance for the bimorph, the measured N ≈ 700 pT/√Hz. We discuss models based on magneto-electro-mechanical coupling at low frequency and bending resonance in the sensors and theoretical estimates of ME voltage coefficients are in very good agreement with the data.

  19. Shielding of Sensitive Electronic Devices in Magnetic Nanoparticle Hyperthermia Using Arrays of Coils

    International Nuclear Information System (INIS)

    Spirou, S V; Tsialios, P; Loudos, G

    2015-01-01

    In Magnetic Nanoparticle Hyperthermia (MNH) an externally applied electromagnetic field transfers energy to the magnetic nanoparticles in the body, which in turn convert this energy into heat, thus locally heating the tissue they are located in. This external electromagnetic field is sufficiently strong so as to cause interference and affect sensitive electronic equipment. Standard shielding of magnetic fields involves Faraday cages or coating with high-permeability shielding alloys; however, these techniques cannot be used with optically sensitive devices, such as those employed in Optical Coherence Tomography or radionuclide imaging. In this work we present a method to achieve magnetic shielding using an array of coils. The magnetic field generated by a single coil was calculated using the COMSOL physics simulation toolkit. Software was written in C/C++ to import the single-coil data, and then calculate the positions, number of turns and currents in the shielding coils in order to minimize the magnetic field strength at the desired location. Simulations and calculations have shown that just two shielding coils can reduce the magnetic field by 2-3 orders of magnitude. (paper)

  20. Shielding of Sensitive Electronic Devices in Magnetic Nanoparticle Hyperthermia Using Arrays of Coils

    Science.gov (United States)

    Spirou, S. V.; Tsialios, P.; Loudos, G.

    2015-09-01

    In Magnetic Nanoparticle Hyperthermia (MNH) an externally applied electromagnetic field transfers energy to the magnetic nanoparticles in the body, which in turn convert this energy into heat, thus locally heating the tissue they are located in. This external electromagnetic field is sufficiently strong so as to cause interference and affect sensitive electronic equipment. Standard shielding of magnetic fields involves Faraday cages or coating with high-permeability shielding alloys; however, these techniques cannot be used with optically sensitive devices, such as those employed in Optical Coherence Tomography or radionuclide imaging. In this work we present a method to achieve magnetic shielding using an array of coils. The magnetic field generated by a single coil was calculated using the COMSOL physics simulation toolkit. Software was written in C/C++ to import the single-coil data, and then calculate the positions, number of turns and currents in the shielding coils in order to minimize the magnetic field strength at the desired location. Simulations and calculations have shown that just two shielding coils can reduce the magnetic field by 2-3 orders of magnitude.

  1. Sensitivity of proposed search for axion-induced magnetic field using optically pumped magnetometers

    Science.gov (United States)

    Chu, P.-H.; Duffy, L. D.; Kim, Y. J.; Savukov, I. M.

    2018-04-01

    We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014), 10.1103/PhysRevLett.112.131301]. The modification of Maxwell's equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. We discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10-7 GeV-1 for an axion mass near 3 ×10-10 eV , which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10-11 and 10-7 eV .

  2. Resonance reactions and enhancement of weak interactions in collisions of cold molecules

    International Nuclear Information System (INIS)

    Flambaum, V. V.; Ginges, J. S. M.

    2006-01-01

    With the creation of ultracold atoms and molecules, a new type of chemistry - 'resonance' chemistry - emerges: chemical reactions can occur when the energy of colliding atoms and molecules matches a bound state of the combined molecule (Feshbach resonance). This chemistry is rather similar to reactions that take place in nuclei at low energies. In this paper we suggest some problems for future experimental and theoretical work related to the resonance chemistry of ultracold molecules. Molecular Bose-Einstein condensates are particularly interesting because in this system collisions and chemical reactions are extremely sensitive to weak fields; also, a preferred reaction channel may be enhanced due to a finite number of final states. The sensitivity to weak fields arises due to the high density of narrow compound resonances and the macroscopic number of molecules with kinetic energy E=0 (in the ground state of a mean-field potential). The high sensitivity to the magnetic field may be used to measure the distribution of energy intervals, widths, and magnetic moments of compound resonances and study the onset of quantum chaos. A difference in the production rate of right-handed and left-handed chiral molecules may be produced by external electric E and magnetic B fields and the finite width Γ of the resonance (correlation ΓE·B). The same effect may be produced by the parity-violating energy difference in chiral molecules

  3. Armature reaction of permanent magnet-excited small dc motors with shell type magnets and possibilities of power increase

    Energy Technology Data Exchange (ETDEWEB)

    Gutt, H J; Tran, Q N

    1983-07-01

    Permanent magnet-excited small dc motors allow an increase of power up to 30% compared with present permanent excited motors. The calculation of immediate irreversible demagnetization of the air-gap situated shell type magnets is necessary for a good motor design. Numerical calculated field line plots show the critical zones of the irreversible demagnetization at high armature reaction and refer how to avoid the flux loss and to increase the motor power.

  4. The Maillard Reaction Reduced the Sensitization of Tropomyosin and Arginine Kinase from Scylla paramamosain, Simultaneously.

    Science.gov (United States)

    Han, Xin-Yu; Yang, Huang; Rao, Shi-Tao; Liu, Guang-Yu; Hu, Meng-Jun; Zeng, Bin-Chang; Cao, Min-Jie; Liu, Guang-Ming

    2018-03-21

    The Maillard reaction was established to reduce the sensitization of tropomyosin (TM) and arginine kinase (AK) from Scylla paramamosain, and the mechanism of the attenuated sensitization was investigated. In the present study, the Maillard reaction conditions were optimized for heating at 100 °C for 60 min (pH 8.5) with arabinose. A low level of allergenicity in mice was shown by the levels of allergen-specific antibodies, and more Th1 and less Th2 cells cytokines produced and associated transcription factors with the Maillard reacted allergen (mAllergen). The tolerance potency in mice was demonstrated by the increased ratio of Th1/Th2 cytokines. Moreover, mass spectrometry analysis showed that some key amino acids of IgE-binding epitopes (K 112 , R 125 , R 133 of TM; K 33 , K 118 , R 202 of AK) were modified by the Maillard reaction. The Maillard reaction with arabinose reduced the sensitization of TM and AK, which may be due to the masked epitopes.

  5. Exploring on the Sensitivity Changes of the LC Resonance Magnetic Sensors Affected by Superposed Ringing Signals.

    Science.gov (United States)

    Lin, Tingting; Zhou, Kun; Yu, Sijia; Wang, Pengfei; Wan, Ling; Zhao, Jing

    2018-04-25

    LC resonance magnetic sensors are widely used in low-field nuclear magnetic resonance (LF-NMR) and surface nuclear magnetic resonance (SNMR) due to their high sensitivity, low cost and simple design. In magnetically shielded rooms, LC resonance magnetic sensors can exhibit sensitivities at the fT/√Hz level in the kHz range. However, since the equivalent magnetic field noise of this type of sensor is greatly affected by the environment, weak signals are often submerged in practical applications, resulting in relatively low signal-to-noise ratios (SNRs). To determine why noise increases in unshielded environments, we analysed the noise levels of an LC resonance magnetic sensor ( L ≠ 0) and a Hall sensor ( L ≈ 0) in different environments. The experiments and simulations indicated that the superposed ringing of the LC resonance magnetic sensors led to the observed increase in white noise level caused by environmental interference. Nevertheless, ringing is an inherent characteristic of LC resonance magnetic sensors. It cannot be eliminated when environmental interference exists. In response to this problem, we proposed a method that uses matching resistors with various values to adjust the quality factor Q of the LC resonance magnetic sensor in different measurement environments to obtain the best sensitivity. The LF-NMR experiment in the laboratory showed that the SNR is improved significantly when the LC resonance magnetic sensor with the best sensitivity is selected for signal acquisition in the light of the test environment. (When the matching resistance is 10 kΩ, the SNR is 3.46 times that of 510 Ω). This study improves LC resonance magnetic sensors for nuclear magnetic resonance (NMR) detection in a variety of environments.

  6. Highly sensitive spectrophotometric kinetic determination of vanadium by catalysis of the gallic acid-bromate reaction

    International Nuclear Information System (INIS)

    Fukasawa, Tsutomu; Kawakubo, Susumu; Yamanouchi, Tatsuo

    1985-01-01

    Conditions are described for improving the speed and sensitivity of this catalytic determination of vanadium. The reaction of 0.018 M gallic acid with 0.96 M sodium bromate at pH 3.8 and double-beam spectrophotometric measurement at 380 nm are recommended. The highest practical sensitivity at 22-30 0 C was ca. 40 pg for an absorbance change of 0.0005, 50 times better than previously. The detection limit was ca. 0.5 ng of vanadium. Reaction at 50 0 C gave even better sensitivity. (Auth.)

  7. The magnetic form factor of the neutron, GMn, from the d(e,e'n)p reaction

    International Nuclear Information System (INIS)

    Markowitz, P.E.C.

    1992-01-01

    The author measured the d(e,e'n)p cross-section at three values of Q 2 : 0.255, 0.176 and 0.109 (GeV/c) 2 . The electrons were detected with the OHIPS magnetic spectrometer, and the neutrons were detected in a liquid mineral oil scintillator array. The measurement were made at a fixed neutron angle of θ n = 57 degrees; the Q 2 values were obtained by varying the incident electron energy and the scattering angle. These cross sections are sensitive primarily to the neutron magnetic form factor at these quasifree kinematics. The efficiency of the neutron detector was determined by the associated particle technique with the d(γ, pn) reaction for each of three neutron kinetic energies. The value of G n M extracted from the cross sections are consistent with the dipole parametrization at the two high momentum transfers; at the lowest momentum transfer the value of G n M is 10% higher than the dipole model. This enhancement at low momentum transfer is consistent with previous measurements

  8. Unsteady Bioconvection Squeezing Flow in a Horizontal Channel with Chemical Reaction and Magnetic Field Effects

    Directory of Open Access Journals (Sweden)

    Qingkai Zhao

    2017-01-01

    Full Text Available The time-dependent mixed bioconvection flow of an electrically conducting fluid between two infinite parallel plates in the presence of a magnetic field and a first-order chemical reaction is investigated. The fully coupled nonlinear systems describing the total mass, momentum, thermal energy, mass diffusion, and microorganisms equations are reduced to a set of ordinary differential equations via a set of new similarity transformations. The detailed analysis illustrating the influences of various physical parameters such as the magnetic, squeezing, and chemical reaction parameters and the Schmidt and Prandtl numbers on the distributions of temperature and microorganisms as well as the skin friction and the Nusselt number is presented. The conclusion is drawn that the flow field, temperature, and chemical reaction profiles are significantly influenced by magnetic parameter, heat generation/absorption parameter, and chemical parameter. Some examples of potential applications of such bioconvection could be found in pharmaceutical industry, microfluidic devices, microbial enhanced oil recovery, modeling oil, and gas-bearing sedimentary basins.

  9. Single-core magnetic markers in rotating magnetic field based homogeneous bioassays and the law of mass action

    Energy Technology Data Exchange (ETDEWEB)

    Dieckhoff, Jan, E-mail: j.dieckhoff@tu-bs.de [Institut fuer Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig (Germany); Schrittwieser, Stefan; Schotter, Joerg [Molecular Diagnostics, AIT Austrian Institute of Technology, Vienna (Austria); Remmer, Hilke; Schilling, Meinhard; Ludwig, Frank [Institut fuer Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig (Germany)

    2015-04-15

    In this work, we report on the effect of the magnetic nanoparticle (MNP) concentration on the quantitative detection of proteins in solution with a rotating magnetic field (RMF) based homogeneous bioassay. Here, the phase lag between 30 nm iron oxide single-core particles and the RMF is analyzed with a fluxgate-based measurement system. As a test analyte anti-human IgG is applied which binds to the protein G functionalized MNP shell and causes a change of the phase lag. The measured phase lag changes for a fixed MNP and a varying analyte concentration are modeled with logistic functions. A change of the MNP concentration results in a nonlinear shift of the logistic function with the analyte concentration. This effect results from the law of mass action. Furthermore, the bioassay results are used to determine the association constant of the binding reaction. - Highlights: • A rotating magnetic field based homogeneous bioassay concept was presented. • Here, single-core iron oxide nanoparticles are applied as markers. • The impact of the particle concentration on the bioassay results is investigated. • The relation between particle concentration and bioassay sensitivity is nonlinear. • This finding can be reasonably explained by the law of mass action.

  10. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  11. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Directory of Open Access Journals (Sweden)

    Georgios Arampatzis

    Full Text Available Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of

  12. Magnetically Separable Iron Oxide Nanoparticles: An Efficient and Reusable Catalyst for Imino Diels-Alder Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Basavegowda, Nagaraj; Mishra, Kanchan; Lee, Yong Rok; Joh, Young-Gull [Yeungnam University, Gyeongsan (Korea, Republic of)

    2016-02-15

    Iron oxide nanoparticles were synthesized using Saururus chinensis (S. chinensis) leaf extract as a reducing and stabilizing agent via ultrasonication. The size, morphology, crystallinity, elemental composition, weight loss, surface chemical state, and magnetic properties of the synthesized nanoparticles were investigated. The synthe-sized nanoparticles were used as an efficient and recyclable catalyst for the synthesis of a variety of 2-methyl-4-substituted-1,2,3,4-tetrahydroquinoline derivatives by the imino Diels-Alder reaction. After the reaction, the catalyst was recovered by an external magnetic field. The recovered catalyst was then reused in a subsequent reaction under identical conditions. The recycled iron oxide nanoparticles (IONPs) were reused five times with-out any significant loss of catalytic activity.

  13. Magnetically Separable Iron Oxide Nanoparticles: An Efficient and Reusable Catalyst for Imino Diels-Alder Reaction

    International Nuclear Information System (INIS)

    Basavegowda, Nagaraj; Mishra, Kanchan; Lee, Yong Rok; Joh, Young-Gull

    2016-01-01

    Iron oxide nanoparticles were synthesized using Saururus chinensis (S. chinensis) leaf extract as a reducing and stabilizing agent via ultrasonication. The size, morphology, crystallinity, elemental composition, weight loss, surface chemical state, and magnetic properties of the synthesized nanoparticles were investigated. The synthe-sized nanoparticles were used as an efficient and recyclable catalyst for the synthesis of a variety of 2-methyl-4-substituted-1,2,3,4-tetrahydroquinoline derivatives by the imino Diels-Alder reaction. After the reaction, the catalyst was recovered by an external magnetic field. The recovered catalyst was then reused in a subsequent reaction under identical conditions. The recycled iron oxide nanoparticles (IONPs) were reused five times with-out any significant loss of catalytic activity.

  14. Velocity-space observation regions of high-resolution two-step reaction gamma-ray spectroscopy

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nocente, M.; Gorini, G.

    2015-01-01

    High-resolution γ-ray spectroscopy (GRS) measurements resolve spectral shapes of Dopplerbroadened γ-rays. We calculate weight functions describing velocity-space sensitivities of any two-step reaction GRS measurements in magnetized plasmas using the resonant nuclear reaction 9Be(α, nγ)12C...

  15. Sensitivity enhancement by chromatographic peak concentration with ultra-high performance liquid chromatography-nuclear magnetic resonance spectroscopy for minor impurity analysis.

    Science.gov (United States)

    Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko

    2017-07-28

    High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Transformation-Dissolution Reactions Partially Explain Adverse Effects of Metallic Silver Nanoparticles to Soil Nitrification in Different Soils.

    Science.gov (United States)

    Bollyn, Jessica; Willaert, Bernd; Kerré, Bart; Moens, Claudia; Arijs, Katrien; Mertens, Jelle; Leverett, Dean; Oorts, Koen; Smolders, Erik

    2018-04-25

    Risk assessment of metallic nanoparticles (NP) is critically affected by the concern that toxicity goes beyond that of the metallic ion. This study addressed this concern for soils with silver (Ag)-NP using the Ag-sensitive nitrification assay. Three agricultural soils (A,B,C) were spiked with equivalent Ag doses of either Ag-NP (d = 13 nm) or AgNO 3 . Soil solution was isolated and monitored over 97 days with due attention to accurate Ag fractionation at low (∼10 µg L -1 ) Ag concentrations. Truly dissolved (soils decreased with reaction half-lives of 4 to 22 days depending on the soil, denoting important Ag-ageing reactions. In contrast, truly dissolved Ag in Ag-NP-amended soils first increased by dissolution and subsequently decreased by ageing; the concentration never exceeding that in the AgNO 3 -amended soils. The half-lives of Ag-NP transformation-dissolution were about 4 days (soils A&B) and 36 days (soil C). The Ag toxic thresholds (EC10, mg Ag kg -1 soil) of nitrification, either evaluated at 21 or 35 days after spiking, were similar between the two Ag forms (soils A&B) but were factors 3 to 8 lower for AgNO 3 than for Ag-NP (soil C), largely corroborating with dissolution differences. This fate and bio-assay showed that Ag-NPs are not more toxic than AgNO 3 at equivalent total soil Ag concentrations and that differences in Ag-dissolution at least partially explain toxicity differences between the forms and among soils. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Sunflower oil ozonation. Following of the reaction by proton Nuclear Magnetic Resonance

    International Nuclear Information System (INIS)

    Diaz Gomez, Maritza F.

    2005-01-01

    Previous studies have demonstrated that the technique of Proton Nuclear Magnetic Resonance can be used for the pursuit of the reaction between the ozone and the unsaturated fatty acids. It's carried out the sunflower oil ozonization to different applied dose of ozone and the index of peroxides and the concentration of aldehydes are determined. The main reaction products were identified by Proton Nuclear Magnetic Resonance Spectroscopy (NMR 1 H). The intensities of the signs were used to follow the advance of the reaction between the ozone and the sunflower oil. It is was carried out until obtaining an index of peroxides of 1 202 mmol-equiv/kg. The intensities of the signs of the olefinic protons diminish with a gradual increment in the dose of applied ozone, but without ending up disappearing completely. The ozonides of Criegee obtained to applied dose of ozone of 107,1 mg/g were approximately bigger 7,4 times that those obtained at the beginning from the reaction to applied dose of ozone of 15,3 mg/g. The aldehydes protons were observed as a sign of weak intensity in all the spectra. The signs belonging to the olenifics protons of the hydroperoxides in d = 5,55 ppm increases with the increment of the applied dose of ozone. You concludes that to higher applied dose of ozone, haggler is the advance of the ozonization reaction, what belongs together with a bigger formation of oxygenated compounds

  18. Magnetic domains and magnetic stability of cohenite from the Morasko iron meteorite

    Energy Technology Data Exchange (ETDEWEB)

    Reznik, B. [Institute of Applied Geosciences, Karlsruhe Institute of Technology, Karlsruhe (Germany); Kontny, A., E-mail: agnes.kontny@kit.edu [Institute of Applied Geosciences, Karlsruhe Institute of Technology, Karlsruhe (Germany); Uehara, M.; Gattacceca, J. [CNRS, Aix Marseille Univ, IRD, Coll France, CEREGE, Aix-en-Provence (France); Solheid, P.; Jackson, M. [Institute for Rock Magnetism, University of Minnesota, Minneapolis, MN (United States)

    2017-03-15

    Magnetic properties, texture and microstructure of cohenite grains from Morasko iron meteorite have been investigated using electron backscattered diffraction, Bitter pattern technique, magneto-optical imaging method and magnetic force microscopy. Cohenite shows much stronger magnetic contrast compared to kamacite because it is magnetically harder than the Fe-Ni alloy, and thus causes higher stray fields. A surprising result is the high stability and reversibility of the global stripe-like magnetic domain structure in cohenite when applying high magnetic fields up to 1.5 T, and exposing it to high temperatures above the Curie temperature of about 220 °C. Heating up to 700 °C under atmosphere conditions has shown that cohenite remains stable and that the global magnetic domain structures mainly recover to its preheating state. This observation suggests that magnetic domains are strongly controlled by the crystal anisotropy of cohenite. Branching magnetic domain structures at the grain boundary to kamacite can be annealed, which indicates that they are very sensitive to record deformation. EBSD observations clearly demonstrate that increasing deviation from the easy [010] crystallographic axis and stress localization are the main factors controlling the distortion of Bitter patterns, and suggest a high sensitivity of the cohenite magnetic domain structure to local microstructural heterogeneities. The results of this study substantiate the theory that cohenite can be a good recorder of magnetic fields in planetary core material. - Highlights: • Magnetic domain structure of cohenite from the Morasko iron meteorite was investigated by Bitter pattern method, magneto-optical imaging and magnetic force microscopy. • Strong magnetocrystalline anisotropy explains high magnetic stability. • Magnetic domain structure shows high sensitivity to local microstructural heterogeneities. • Cohenite is probably a good recorder of magnetic fields in planetary core material.

  19. Magnetic domains and magnetic stability of cohenite from the Morasko iron meteorite

    International Nuclear Information System (INIS)

    Reznik, B.; Kontny, A.; Uehara, M.; Gattacceca, J.; Solheid, P.; Jackson, M.

    2017-01-01

    Magnetic properties, texture and microstructure of cohenite grains from Morasko iron meteorite have been investigated using electron backscattered diffraction, Bitter pattern technique, magneto-optical imaging method and magnetic force microscopy. Cohenite shows much stronger magnetic contrast compared to kamacite because it is magnetically harder than the Fe-Ni alloy, and thus causes higher stray fields. A surprising result is the high stability and reversibility of the global stripe-like magnetic domain structure in cohenite when applying high magnetic fields up to 1.5 T, and exposing it to high temperatures above the Curie temperature of about 220 °C. Heating up to 700 °C under atmosphere conditions has shown that cohenite remains stable and that the global magnetic domain structures mainly recover to its preheating state. This observation suggests that magnetic domains are strongly controlled by the crystal anisotropy of cohenite. Branching magnetic domain structures at the grain boundary to kamacite can be annealed, which indicates that they are very sensitive to record deformation. EBSD observations clearly demonstrate that increasing deviation from the easy [010] crystallographic axis and stress localization are the main factors controlling the distortion of Bitter patterns, and suggest a high sensitivity of the cohenite magnetic domain structure to local microstructural heterogeneities. The results of this study substantiate the theory that cohenite can be a good recorder of magnetic fields in planetary core material. - Highlights: • Magnetic domain structure of cohenite from the Morasko iron meteorite was investigated by Bitter pattern method, magneto-optical imaging and magnetic force microscopy. • Strong magnetocrystalline anisotropy explains high magnetic stability. • Magnetic domain structure shows high sensitivity to local microstructural heterogeneities. • Cohenite is probably a good recorder of magnetic fields in planetary core material.

  20. Fabrication of a pen-shaped portable biochemical reaction system based on magnetic bead manipulation

    International Nuclear Information System (INIS)

    Shikida, Mitsuhiro; Inagaki, Noriyuki; Okochi, Mina; Honda, Hiroyuki; Sato, Kazuo

    2011-01-01

    A pen-shaped platform that is similar to a mechanical pencil is proposed for producing a portable reaction system. A reaction unit, as the key component in the system, was produced by using a heat shrinkable tube. A mechanical pencil supplied by Mitsubishi Pencil Co. Ltd was used as the pen-shaped platform for driving the reaction cylinder. It was actuated using an inchworm motion. We confirmed that the magnetic beads were successfully manipulated in the droplet in the cylinder-shaped reaction units. (technical note)

  1. High resolution studies of the effects of magnetic fields on chemical reactions

    OpenAIRE

    Hamilton, C. A.; Hewitt, J. P.; McLauchlan, Keith A.; Steiner, Ulrich

    1988-01-01

    A simple and inexpensive experiment is described which detects magnetic field effects on chemical reactions with high signal-to-noise ratio and high resolution. It consists in applying a small modulation field to the sample, whilst the main field it experiences is varied, with optical detection at the modulation frequency. It consequently measures the derivative of the normal MARY spectrum. It is shown by theoretical analysis that when using this method it is better to monitor reaction interm...

  2. Light-Activated Magnetic Compass in Birds

    DEFF Research Database (Denmark)

    Solov'yov, Ilia; Greiner, Walter

    2013-01-01

    Migrating birds fly thousand miles without having a map, or a GPS unit. But they may carry their own sensitive navigational tool, which allows them "see" the Earth’s magnetic field. Here we review the important physical and chemical constraints on a possible compass sensor and discuss the suggest......Migrating birds fly thousand miles without having a map, or a GPS unit. But they may carry their own sensitive navigational tool, which allows them "see" the Earth’s magnetic field. Here we review the important physical and chemical constraints on a possible compass sensor and discuss...... the suggestion that radical pairs in a photoreceptor cryptochrome might provide a biological realization for a magnetic compass. Finally, we review the current evidence supporting a role for radical pair reactions in the magnetic compass of birds....

  3. MRI of chemical reactions and processes.

    Science.gov (United States)

    Britton, Melanie M

    2017-08-01

    As magnetic resonance imaging (MRI) can spatially resolve a wealth of molecular information available from nuclear magnetic resonance (NMR), it is able to non-invasively visualise the composition, properties and reactions of a broad range of spatially-heterogeneous molecular systems. Hence, MRI is increasingly finding applications in the study of chemical reactions and processes in a diverse range of environments and technologies. This article will explain the basic principles of MRI and how it can be used to visualise chemical composition and molecular properties, providing an overview of the variety of information available. Examples are drawn from the disciplines of chemistry, chemical engineering, environmental science, physics, electrochemistry and materials science. The review introduces a range of techniques used to produce image contrast, along with the chemical and molecular insight accessible through them. Methods for mapping the distribution of chemical species, using chemical shift imaging or spatially-resolved spectroscopy, are reviewed, as well as methods for visualising physical state, temperature, current density, flow velocities and molecular diffusion. Strategies for imaging materials with low signal intensity, such as those containing gases or low sensitivity nuclei, using compressed sensing, para-hydrogen or polarisation transfer, are discussed. Systems are presented which encapsulate the diversity of chemical and physical parameters observable by MRI, including one- and two-phase flow in porous media, chemical pattern formation, phase transformations and hydrodynamic (fingering) instabilities. Lastly, the emerging area of electrochemical MRI is discussed, with studies presented on the visualisation of electrochemical deposition and dissolution processes during corrosion and the operation of batteries, supercapacitors and fuel cells. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  4. SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, keff, and α Using PARTISN

    Energy Technology Data Exchange (ETDEWEB)

    Favorite, Jeffrey A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-11-21

    SENSMG is a tool for computing first-order sensitivities of neutron reaction rates, reaction-rate ratios, leakage, keff, and α using the PARTISN multigroup discrete-ordinates code. SENSMG computes sensitivities to all of the transport cross sections and data (total, fission, nu, chi, and all scattering moments), two edit cross sections (absorption and capture), and the density for every isotope and energy group. It also computes sensitivities to the mass density for every material and derivatives with respect to all interface locations. The tool can be used for one-dimensional spherical (r) and two-dimensional cylindrical (r-z) geometries. The tool can be used for fixed-source and eigenvalue problems. The tool implements Generalized Perturbation Theory (GPT) as discussed by Williams and Stacey. Section II of this report describes the theory behind adjoint-based sensitivities, gives the equations that SENSMG solves, and defines the sensitivities that are output. Section III describes the user interface, including the input file and command line options. Section IV describes the output. Section V gives some notes about the coding that may be of interest. Section VI discusses verification, which is ongoing. Section VII lists needs and ideas for future work. Appendix A lists all of the input files whose results are presented in Sec. VI.

  5. Magnetic and sensitive magnetoelastic properties of Finemet nanostructured ribbon

    International Nuclear Information System (INIS)

    Pham Duc Thang; Hoang Hai Duong; Nguyen Hoang Nghi

    2009-01-01

    Soft-magnetic Fe 73.5 Cu 1 Nb 3 Si 13.5 B 9 (Finemet) ribbon has been fabricated by using melt-spinning techniques. After annealing at suitable temperature the ribbon changes from an amorphous to crystalline state which related to the formation of Fe nanocrystallites. Study on the magnetic and magnetoelastic properties of the ribbon is presented. Furthermore, based on the fabricated ribbon stress sensors are simply constructed. The sensors showed high sensitivity of 3.8 mV/MPa as well as a wide working range up to 17 MPa. These sensors are potential for practical applications such as detecting small stress and movement in civil structures.

  6. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Science.gov (United States)

    de Sá Neto, José Luiz; Simão, Marcelo Novelino; Crema, Michel Daoud; Engel, Edgard Eduard; Nogueira-Barbosa, Marcello Henrique

    2017-01-01

    Objective: To evaluate the performance of magnetic resonance imaging (MRI) in detecting periosteal reactions and to compare MRI and conventional radiography (CR) in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men) with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05). Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction. PMID:28670029

  7. Time-resolved optical absorption microspectroscopy of magnetic field sensitive flavin photochemistry

    Science.gov (United States)

    Antill, Lewis M.; Beardmore, Joshua P.; Woodward, Jonathan R.

    2018-02-01

    The photochemical reactions of blue-light receptor proteins have received much attention due to their very important biological functions. In addition, there is also growing evidence that the one particular class of such proteins, the cryptochromes, may be associated with not only a biological photo-response but also a magneto-response, which may be responsible for the mechanism by which many animals can respond to the weak geomagnetic field. Therefore, there is an important scientific question over whether it is possible to directly observe such photochemical processes, and indeed the effects of weak magnetic fields thereon, taking place both in purified protein samples in vitro and in actual biochemical cells and tissues. For the former samples, the key lies in being able to make sensitive spectroscopic measurements on very small volumes of samples at potentially low protein concentrations, while the latter requires, in addition, spatially resolved measurements on length scales smaller than typical cellular components, i.e., sub-micron resolution. In this work, we discuss a two- and three-color confocal pump-probe microscopic approach to this question which satisfies these requirements and is thus useful for experimental measurements in both cases.

  8. Global sensitivity analysis in stochastic simulators of uncertain reaction networks.

    Science.gov (United States)

    Navarro Jimenez, M; Le Maître, O P; Knio, O M

    2016-12-28

    Stochastic models of chemical systems are often subjected to uncertainties in kinetic parameters in addition to the inherent random nature of their dynamics. Uncertainty quantification in such systems is generally achieved by means of sensitivity analyses in which one characterizes the variability with the uncertain kinetic parameters of the first statistical moments of model predictions. In this work, we propose an original global sensitivity analysis method where the parametric and inherent variability sources are both treated through Sobol's decomposition of the variance into contributions from arbitrary subset of uncertain parameters and stochastic reaction channels. The conceptual development only assumes that the inherent and parametric sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. A sampling algorithm is proposed to perform the global sensitivity analysis, and to estimate the partial variances and sensitivity indices characterizing the importance of the various sources of variability and their interactions. The birth-death and Schlögl models are used to illustrate both the implementation of the algorithm and the richness of the proposed analysis method. The output of the proposed sensitivity analysis is also contrasted with a local derivative-based sensitivity analysis method classically used for this type of systems.

  9. Global sensitivity analysis in stochastic simulators of uncertain reaction networks

    KAUST Repository

    Navarro, María

    2016-12-26

    Stochastic models of chemical systems are often subjected to uncertainties in kinetic parameters in addition to the inherent random nature of their dynamics. Uncertainty quantification in such systems is generally achieved by means of sensitivity analyses in which one characterizes the variability with the uncertain kinetic parameters of the first statistical moments of model predictions. In this work, we propose an original global sensitivity analysis method where the parametric and inherent variability sources are both treated through Sobol’s decomposition of the variance into contributions from arbitrary subset of uncertain parameters and stochastic reaction channels. The conceptual development only assumes that the inherent and parametric sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. A sampling algorithm is proposed to perform the global sensitivity analysis, and to estimate the partial variances and sensitivity indices characterizing the importance of the various sources of variability and their interactions. The birth-death and Schlögl models are used to illustrate both the implementation of the algorithm and the richness of the proposed analysis method. The output of the proposed sensitivity analysis is also contrasted with a local derivative-based sensitivity analysis method classically used for this type of systems.

  10. Fusion, magnetic confinement

    International Nuclear Information System (INIS)

    Berk, H.L.

    1992-01-01

    An overview is presented of the principles of magnetic confinement of plasmas for the purpose of achieving controlled fusion conditions. Sec. 1 discusses the different nuclear fusion reactions which can be exploited in prospective fusion reactors and explains why special technologies need to be developed for the supply of tritium or 3 He, the probable fuels. In Sec. 2 the Lawson condition, a criterion that is a measure of the quality of confinement relative to achieving fusion conditions, is explained. In Sec. 3 fluid equations are used to describe plasma confinement. Specific confinement configurations are considered. In Sec. 4 the orbits of particle sin magneti and electric fields are discussed. In Sec. 5 stability considerations are discussed. It is noted that confinement systems usually need to satisfy stability constraints imposed by ideal magnetohydrodynamic (MHD) theory. The paper culminates with a summary of experimental progress in magnetic confinement. Present experiments in tokamaks have reached the point that the conditions necessary to achieve fusion are being satisfied

  11. Carbon-coated magnetic palladium: applications in partial oxidation of alcohols and coupling reactions.

    Science.gov (United States)

    Magnetic carbon supported Pd catalyst has been synthesized via in situ generation of nanoferrites and incorporation of carbon from renewable cellulose via calcination; catalyst can be used for oxidation of alcohols, amination reaction and arylation of aryl halides (cross coupli...

  12. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Directory of Open Access Journals (Sweden)

    José Luiz de Sá Neto

    Full Text Available Abstract Objective: To evaluate the performance of magnetic resonance imaging (MRI in detecting periosteal reactions and to compare MRI and conventional radiography (CR in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05. Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction.

  13. Lattice Boltzmann simulation for temperature-sensitive magnetic fluids in a porous square cavity

    International Nuclear Information System (INIS)

    Jin Licong; Zhang Xinrong; Niu Xiaodong

    2012-01-01

    A lattice Boltzmann method is developed to simulate temperature-sensitive magnetic fluids in a porous cavity. In the simulation, the magnetic force, efficient gravity, viscous loss term and geometric loss term in porous medium are imported to the momentum equation. To test the reliability of the method, a validation with water in porous cavity is carried out. Good agreements with the previous results verify that the present lattice Boltzmann method is promising for simulation of magnetic fluids in porous medium. In this study, we investigate the change of magnetization with external magnetic field, and we present numerical results for the streamlines, isotherms, and magnetization at vertical or horizontal mid-profiles for different values of Ram. In addition, Nusselt numbers changing with magnetic Rayleigh numbers are also investigated. - Highlights: → Developed a lattice Boltzmann method for magnetic nano-fluids in porous cavity. → Clarified flow and heat transfer for different values of (magnetic) Rayleigh numbers. → Heat transfer enhancement for magnetic fluid in porous cavity.

  14. Magnetic properties of ZnFe2O4 nanoparticles produced by a low-temperature solid-state reaction method

    International Nuclear Information System (INIS)

    Li Fashen; Wang Haibo; Wang Li; Wang Jianbo

    2007-01-01

    ZnFe 2 O 4 nanoparticles with average grain size ranging from 40 to 60 nm behaving superparamagnetic at room temperature have been produced using a low-temperature solid-state reaction (LTSSR) method without ball-milling process. Abnormal magnetic properties such as S-shape hysteresis loops and non-zero magnetic moments were observed. ZnFe 2 O 4 nanoparticles were also synthesized using a NaOH coprecipitation method and a PVA sol-gel method to study the relationship between the preparation processes and the magnetic properties. Spin-glass behavior was observed in the low temperature solid-state reaction produced Zn ferrite in the zero-field cooled (ZFC) measurement. Our work proves that the various preparation methods will to some extent determine the properties of magnetic nanoparticles

  15. Applications of the absolute reaction rate theory to biological responses in electric and magnetic fields

    International Nuclear Information System (INIS)

    Brannen, J.P.; Wayland, J.R.

    1976-01-01

    This paper develops a theoretical foundation for the study of biological responses of electric and magnetic fields. The basis of the development is the absolute reaction rate theory and the effects of fields on reaction rates. A simple application to the response of Bacillus subtilis var niger in a microwave field is made. Potential areas of application are discussed

  16. Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

    Science.gov (United States)

    Bandler, SImon; Stevenson, Thomas; Hsieh, Wen-Ting

    2011-01-01

    Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or

  17. Magnetic Resonance Determinations of Structure and Reaction Kinetics of Epoxy/Amine Systems.

    Science.gov (United States)

    1981-12-31

    AD- AISA 542 MCDONNELL DOUGLAS RESEARCH LABS ST LOUIS MO FIG 7/4 MAGNETIC RESONANCE DETERMINATIONS OF STRUCTURE AND REACTION KIN--ETC (U) DEC Al I M...solvent content (methylene chloride). DD I JAN73 1473 EDITION OF I NOV 65 IS OBSOLETE UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (When Doe Fntered

  18. Synthesis of ferrofluids based on cobalt ferrite nanoparticles: Influence of reaction time on structural, morphological and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Amirabadizadeh, Ahmad; Salighe, Zohre; Sarhaddi, Reza, E-mail: reza.sarhaddi@birjand.ac.ir; Lotfollahi, Zahra

    2017-07-15

    Highlights: • Ferrofluids based on cobalt ferrite nanoparticles were synthesized by co-precipitation method. • The crystallite and particle size of cobalt ferrite can be controlled effectively by reaction time. • The ferrofluids have lower values of saturation magnetization and coercivity as compared to nanoparticles. • By increasing the size of nanoparticles, the narrower and sharper spikes of ferrofluids are formed. - Abstract: In this work, for first time the ferrofluids based on the cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles were prepared by the co-precipitation method at different reaction times (0.5–6.5 h). Crystal structure, morphology and magnetic properties of the cobalt ferrite nanoparticles and the ferrofluids based on the nanoparticles were studied by X-ray diffraction (XRD), field emission scanning electron microscope (FESEM) and vibrating sample magnetometer (VSM). The XRD patterns of CoFe{sub 2}O{sub 4} nanoparticles synthesized at different reaction times indicated that all samples are single phase in accordance with inverse cubic spinel structure with space group Fd-3m, and no impurity phase was observed. By increasing the reaction time to 3.5 h, the lattice parameter and the average crystallites size increased and then afterwards decreased by increasing the reaction time. The microscopic studies indicated the formation of nanosized particles with nearly spherical in shape, whereas the average particle size for all samples is found to be less than 50 nm. The results of VSM also showed that the saturation magnetization and coercivity field of the cobalt ferrite nanoparticles and the ferrofluids were influenced by reaction time, whereas the ferrofluids have lower values of magnetic parameters than that of nanoparticles.

  19. Reactions to merit pay increases: a longitudinal test of a signal sensitivity perspective.

    Science.gov (United States)

    Shaw, Jason D; Duffy, Michelle K; Mitra, Atul; Lockhart, Daniel E; Bowler, Matthew

    2003-06-01

    The relationships among merit pay raises, trait positive affectivity (PA), and reactions to merit pay increases (pay attitudes and behavioral intentions) were explored in a longitudinal study of hospital employees. Drawing on signal sensitivity theory, the authors expected that PA would moderate the relationship between merit pay raise size and reactions to the increase such that pay raise size would be more strongly related to pay attitudes and behavioral intentions among those low in PA. Results strongly supported the predictions in the case of reactions to the raise amount (happiness and effort intentions) but not for pay level satisfaction. Implications of the results and directions for future research are identified.

  20. Origin of Nanobubbles Electrochemically Formed in a Magnetic Field: Ionic Vacancy Production in Electrode Reaction

    Science.gov (United States)

    Aogaki, Ryoichi; Sugiyama, Atsushi; Miura, Makoto; Oshikiri, Yoshinobu; Miura, Miki; Morimoto, Ryoichi; Takagi, Satoshi; Mogi, Iwao; Yamauchi, Yusuke

    2016-07-01

    As a process complementing conventional electrode reactions, ionic vacancy production in electrode reaction was theoretically examined; whether reaction is anodic or cathodic, based on the momentum conservation by Newton’s second law of motion, electron transfer necessarily leads to the emission of original embryo vacancies, and dielectric polarization endows to them the same electric charge as trans- ferred in the reaction. Then, the emitted embryo vacancies immediately receive the thermal relaxation of solution particles to develop steady-state vacancies. After the vacancy production, nanobubbles are created by the collision of the vacancies in a vertical magnetic field.

  1. Solar monochromatic images in magneto-sensitive spectral lines and maps of vector magnetic fields

    Science.gov (United States)

    Shihui, Y.; Jiehai, J.; Minhan, J.

    1985-01-01

    A new method which allows by use of the monochromatic images in some magneto-sensitive spectra line to derive both the magnetic field strength as well as the angle between magnetic field lines and line of sight for various places in solar active regions is described. In this way two dimensional maps of vector magnetic fields may be constructed. This method was applied to some observational material and reasonable results were obtained. In addition, a project for constructing the three dimensional maps of vector magnetic fields was worked out.

  2. A model explaining synchronization of neuron bioelectric frequency under weak alternating low frequency magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Moral, A. del, E-mail: delmoral@unizar.es [Laboratorio de Magnetismo, Departamento de Física de Materia Condensada and Instituto de Ciencia de Materiales, Universidad de Zaragoza and Consejo Superior de Investigaciones Científicas, 50009 Zaragoza (Spain); Laboratorio de Magnetobiología, Departamento de Anatomía e Histología, Facultad de Medicina, Universidad de Zaragoza, 50009 Zaragoza (Spain); Centro de Tecnología Biomédica, Universidad Politécnica de Madrid, 28223 Madrid (Spain); Azanza, María J., E-mail: mjazanza@unizar.es [Laboratorio de Magnetobiología, Departamento de Anatomía e Histología, Facultad de Medicina, Universidad de Zaragoza, 50009 Zaragoza (Spain); Centro de Tecnología Biomédica, Universidad Politécnica de Madrid, 28223 Madrid (Spain)

    2015-03-01

    A biomagnetic-electrical model is presented that explains rather well the experimentally observed synchronization of the bioelectric potential firing rate (“frequency”), f, of single unit neurons of Helix aspersa mollusc under the application of extremely low frequency (ELF) weak alternating (AC) magnetic fields (MF). The proposed model incorporates to our widely experimentally tested model of superdiamagnetism (SD) and Ca{sup 2+} Coulomb explosion (CE) from lipid (LP) bilayer membrane (SD–CE model), the electrical quadrupolar long range interaction between the bilayer LP membranes of synchronized neuron pairs, not considered before. The quadrupolar interaction is capable of explaining well the observed synchronization. Actual extension of our SD–CE-model shows that the neuron firing frequency field, B, dependence becomes not modified, but the bioelectric frequency is decreased and its spontaneous temperature, T, dependence is modified. A comparison of the model with synchronization experimental results of pair of neurons under weak (B{sub 0}≅0.2–15 mT) AC-MF of frequency f{sub M}=50 Hz is reported. From the deduced size of synchronized LP clusters under B, is suggested the formation of small neuron networks via the membrane lipid correlation. - Highlights: • Neuron pair synchronization under low frequency alternating (AC) magnetic field (MF). • Superdiamagnetism and Ca{sup 2+} Coulomb explosion for AC MF effect in synchronized frequency. • Membrane lipid electrical quadrupolar pair interaction as synchronization mechamism. • Good agreement of model with electrophysiological experiments on mollusc Helix neurons.

  3. A model explaining synchronization of neuron bioelectric frequency under weak alternating low frequency magnetic field

    International Nuclear Information System (INIS)

    Moral, A. del; Azanza, María J.

    2015-01-01

    A biomagnetic-electrical model is presented that explains rather well the experimentally observed synchronization of the bioelectric potential firing rate (“frequency”), f, of single unit neurons of Helix aspersa mollusc under the application of extremely low frequency (ELF) weak alternating (AC) magnetic fields (MF). The proposed model incorporates to our widely experimentally tested model of superdiamagnetism (SD) and Ca 2+ Coulomb explosion (CE) from lipid (LP) bilayer membrane (SD–CE model), the electrical quadrupolar long range interaction between the bilayer LP membranes of synchronized neuron pairs, not considered before. The quadrupolar interaction is capable of explaining well the observed synchronization. Actual extension of our SD–CE-model shows that the neuron firing frequency field, B, dependence becomes not modified, but the bioelectric frequency is decreased and its spontaneous temperature, T, dependence is modified. A comparison of the model with synchronization experimental results of pair of neurons under weak (B 0 ≅0.2–15 mT) AC-MF of frequency f M =50 Hz is reported. From the deduced size of synchronized LP clusters under B, is suggested the formation of small neuron networks via the membrane lipid correlation. - Highlights: • Neuron pair synchronization under low frequency alternating (AC) magnetic field (MF). • Superdiamagnetism and Ca 2+ Coulomb explosion for AC MF effect in synchronized frequency. • Membrane lipid electrical quadrupolar pair interaction as synchronization mechamism. • Good agreement of model with electrophysiological experiments on mollusc Helix neurons

  4. Synthesis of magnetically recyclable ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts and their catalytic performance for Knoevenagel reaction

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qingyuan; Jiang, Sai; Ji, Shengfu, E-mail: jisf@mail.buct.edu.cn; Ammar, Muhammad; Zhang, Qingmin; Yan, Junlei

    2015-03-15

    Novel magnetic ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts were synthesized by encapsulating magnetic SiO{sub 2}@Fe{sub 3}O{sub 4} nanoparticles into ZIF-8 through in situ method. The structures of the catalysts were characterized by TEM, SEM, XRD, FT-IR, VSM, N{sub 2} adsorption/desorption and CO{sub 2}-TPD technology. The catalytic activity and recovery properties of the catalysts for the Knoevenagel reaction of p-chlorobenzaldehyde with malononitrile were evaluated. The results showed that the magnetic ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts had the larger surface areas, the suitable superparamagnetism, and good catalytic activity for Knoevenagel reaction. The conversion of p-chlorobenzaldehyde can reach ~98% and the selectivity of the production can reach ~99% over35.8%ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} (MZC-5) catalyst under the reaction condition of 25 °C and 4 h. The magnetic ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts also had good substrates adaptation. After reaction, the catalyst can be easily separated from the reaction mixture by an external magnet. The recovery catalyst can be reused five times and the conversion of p-chlorobenzaldehyde can be kept over 90%. - Graphical abstract: Novel magnetically recyclable ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts were synthesized by encapsulating magnetic SiO{sub 2}@Fe{sub 3}O{sub 4} nanoparticles into ZIF-8 and the as-synthesized catalysts exhibited a good catalytic activity for the Knoevenagel reaction. - Highlights: • A series of novel magnetic ZIF-8@SiO{sub 2}@Fe{sub 3}O{sub 4} catalysts were synthesized. • The catalysts had the larger surface areas and the suitable superparamagnetism. • The catalysts exhibited good catalytic activity for the Knoevenagel reaction. • After reaction the catalyst can be easily separated by an external magnet. • The recovery catalyst can be reused five times and can keep its catalytic activity.

  5. Achievement of high diode sensitivity via spin torque-induced resonant expulsion in vortex magnetic tunnel junction

    Science.gov (United States)

    Tsunegi, Sumito; Taniguchi, Tomohiro; Yakushiji, Kay; Fukushima, Akio; Yuasa, Shinji; Kubota, Hitoshi

    2018-05-01

    We investigated the spin-torque diode effect in a magnetic tunnel junction with FeB free layer. Vortex-core expulsion was observed near the boundary between vortex and uniform states. A high diode voltage of 24 mV was obtained with alternative input power of 0.3 µW, corresponding to huge diode sensitivity of 80,000 mV/mW. In the expulsion region, a broad peak in the high frequency region was observed, which is attributed to the weak excitation of uniform magnetization by thermal noise. The high diode sensitivity is of great importance for device applications such as telecommunications, radar detectors, and high-speed magnetic-field sensors.

  6. The magnetic moment of NiO nanoparticles determined by Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Bahl, C R H; Hansen, M F; Pedersen, T; Saadi, S; Nielsen, K H; Lebech, B; Moerup, S

    2006-01-01

    We have studied the magnetic properties of 57 Fe-doped NiO nanoparticles using Moessbauer spectroscopy and magnetization measurements. Two samples with different degrees of interparticle interaction were studied. In both samples the particles were characterized by high-resolution transmission electron microscopy and x-ray diffraction and found to be plate-shaped. Computer simulations showed that high-field Moessbauer data are very sensitive to the size of the uncompensated magnetic moment. From analyses of the Moessbauer spectra we have estimated that the size of the uncompensated magnetic moment is in accordance with a model based on random occupation of surface sites. The analyses of the magnetization data gave larger magnetic moments, but the difference can be explained by the different sensitivity of the two methods to a particle size distribution and by interactions between the particles, which may have a strong influence on the moments estimated from magnetization data

  7. Impact of nitrogen doping of niobium superconducting cavities on the sensitivity of surface resistance to trapped magnetic flux

    Science.gov (United States)

    Gonnella, Dan; Kaufman, John; Liepe, Matthias

    2016-02-01

    Future particle accelerators such as the SLAC "Linac Coherent Light Source-II" (LCLS-II) and the proposed Cornell Energy Recovery Linac require hundreds of superconducting radio-frequency (SRF) niobium cavities operating in continuous wave mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor (Q0) to keep cryogenic losses within feasible limits. To reach these high Q0's in the case of LCLS-II, nitrogen-doping of niobium cavities has been selected as the cavity preparation technique. When dealing with Q0's greater than 1 × 1010, the effects of ambient magnetic field on Q0 become significant. Here, we show that the sensitivity to RF losses from trapped magnetic field in a cavity's walls is strongly dependent on the cavity preparation. Specifically, standard electropolished and 120 °C baked cavities show a sensitivity of residual resistance from trapped magnetic flux of ˜0.6 and ˜0.8 nΩ/mG trapped, respectively, while nitrogen-doped cavities show a higher sensitivity of residual resistance from trapped magnetic flux of ˜1 to 5 nΩ/mG trapped. We show that this difference in sensitivities is directly related to the mean free path of the RF surface layer of the niobium: shorter mean free paths lead to less sensitivity of residual resistance to trapped magnetic flux in the dirty limit (ℓ ≪ ξ0), while longer mean free paths lead to lower sensitivity of residual resistance to trapped magnetic flux in the clean limit (ℓ ≫ ξ0). These experimental results are also shown to have good agreement with recent theoretical predictions for pinned vortex lines oscillating in RF fields.

  8. High-temperature sensitivity and its acclimation for photosynthetic electron reactions of desert succulents

    Energy Technology Data Exchange (ETDEWEB)

    Chetti, M.B.; Nobel, P.S. (Univ. of California, Los Angeles (USA))

    1987-08-01

    Photosynthetic electron reactions of succulent plants from hot deserts are able to tolerate extremely high temperatures and to acclimate to seasonal increase in temperature. In this study, we report the influence of relatively long, in vivo, high-temperature treatments on electron transport reactions for two desert succulents, Agave deserti and Opuntia ficus-indica, species which can tolerate 60{degree}C. Whole chain electron transport averaged 3{degree}C more sensitive to a 1-hour high-temperature treatment than did PSII (Photosystem II) which in turn averaged 3{degree}C more sensitive than did PSI. For plants maintained at day/night air temperatures of 30{degree}C/20{degree}C, treatment at 50{degree}C cause these reactions to be inhibited an average of 39% during the first hour, an additional 31% during the next 4 hours, and 100% by 12 hours. Upon shifting the plants from 30{degree}C/20{degree}C to 45{degree}C/35{degree}C, the high temperatures where activity was inhibited 50% increased 3{degree}C to 8{degree}C for the three electron transport reactions, the half-times for acclimation averaging 5 days for A. deserti and 4 days for O. ficus-indica. For the 45{degree}C/35{degree}C plants treated at 60{degree}C for 1 hour, PSI activity was reduced by 54% for A. deserti and 36% for O. ficus-indica. Acclimation leads to a toleration of very high temperatures without substantial disruption of electron transport for these desert succulents, facilitating their survival in hot deserts. Indeed, the electron transport reactions of these species tolerate longer periods at higher temperatures than any other vascular plants so far reported.

  9. Modelling and simulation of a transketolase mediated reaction: Sensitivity analysis of kinetic parameters

    DEFF Research Database (Denmark)

    Sayar, N.A.; Chen, B.H.; Lye, G.J.

    2009-01-01

    In this paper we have used a proposed mathematical model, describing the carbon-carbon bond format ion reaction between beta-hydroxypyruvate and glycolaldehyde to synthesise L-erythrulose, catalysed by the enzyme transketolase, for the analysis of the sensitivity of the process to its kinetic...

  10. Plane-wise sensitivity based inhomogeneous excitation fields for magnetorelaxometry imaging of magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Baumgarten, Daniel, E-mail: daniel.baumgarten@tu-ilmenau.de [Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau (Germany); IJN-UTM Cardiovascular Engineering Centre, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor Bahru (Malaysia); Braune, Friedemann [Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau (Germany); Supriyanto, Eko [IJN-UTM Cardiovascular Engineering Centre, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor Bahru (Malaysia); Haueisen, Jens [Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau (Germany)

    2015-04-15

    Promising biomedical applications of magnetic nanoparticles share the need for a quantitative knowledge of their in vivo distribution. From multichannel magnetorelaxometry measurements with sequential activation of inhomogeneous excitation fields, the distribution can be quantitatively determined. In first studies, single excitation coils were consecutively activated. We aim at further advancing this imaging technology by suitable activation patterns involving multiple excitation coils. In this work, we propose the estimation of these patterns based on the spatial sensitivity in order to reduce the number of required measurements. The sensitivity of a voxel carrying magnetic nanoparticles is determined by its position relative to the sensors and the excitation field. Whereas the position is fixed within a given setup, the excitation is controlled by the currents in the coils. The currents required for a defined target sensitivity are estimated by solving an inverse problem. In our work, two target sensitivity paradigms are presented: (a) plane-wise activation, where only one plane with high sensitivities is sought and moved through the source space and (b) plane-wise non-activation, where all voxels except for one plane should receive high sensitivity. Our approach is investigated in simulation studies using a setup with a cubic region of interest and a planar sensor array. The imaging quality of both activation paradigms is evaluated. Our results demonstrate the principal applicability of this spatial sensitivity based approach for defining inhomogeneous activation patterns. The obtained patterns allow for a similar imaging quality using a lower number of activation sequences compared to the conventional single coil activation.

  11. Plane-wise sensitivity based inhomogeneous excitation fields for magnetorelaxometry imaging of magnetic nanoparticles

    International Nuclear Information System (INIS)

    Baumgarten, Daniel; Braune, Friedemann; Supriyanto, Eko; Haueisen, Jens

    2015-01-01

    Promising biomedical applications of magnetic nanoparticles share the need for a quantitative knowledge of their in vivo distribution. From multichannel magnetorelaxometry measurements with sequential activation of inhomogeneous excitation fields, the distribution can be quantitatively determined. In first studies, single excitation coils were consecutively activated. We aim at further advancing this imaging technology by suitable activation patterns involving multiple excitation coils. In this work, we propose the estimation of these patterns based on the spatial sensitivity in order to reduce the number of required measurements. The sensitivity of a voxel carrying magnetic nanoparticles is determined by its position relative to the sensors and the excitation field. Whereas the position is fixed within a given setup, the excitation is controlled by the currents in the coils. The currents required for a defined target sensitivity are estimated by solving an inverse problem. In our work, two target sensitivity paradigms are presented: (a) plane-wise activation, where only one plane with high sensitivities is sought and moved through the source space and (b) plane-wise non-activation, where all voxels except for one plane should receive high sensitivity. Our approach is investigated in simulation studies using a setup with a cubic region of interest and a planar sensor array. The imaging quality of both activation paradigms is evaluated. Our results demonstrate the principal applicability of this spatial sensitivity based approach for defining inhomogeneous activation patterns. The obtained patterns allow for a similar imaging quality using a lower number of activation sequences compared to the conventional single coil activation

  12. Can the magnetic moment contribution explain the Ay puzzle?

    International Nuclear Information System (INIS)

    Stoks, V.G.

    1998-01-01

    We evaluate the full one-photon-exchange Born amplitude for Nd scattering. We include the contributions due to the magnetic moment of the proton or neutron, and the magnetic moment and quadrupole moment of the deuteron. It is found that the inclusion of the magnetic-moment interaction in the theoretical description of the Nd scattering observables cannot resolve the long-standing A y puzzle. copyright 1998 The American Physical Society

  13. Detecting the sensitivity of magnetic response on different pollution sources--A case study from typical mining cities in northwestern China.

    Science.gov (United States)

    Wang, Bo; Xia, Dunsheng; Yu, Ye; Jia, Jia; Nie, Yan; Wang, Xin

    2015-12-01

    Rapid monitoring and discriminating different anthropogenic pollution is a key scientific issue. To detect the applicability and sensitivity of magnetic measurements for evaluating different industrial pollution in urban environment, characteristics of topsoil from three typical fast developing industrial cities (Jinchang, Baiyin and Jiayuguan in Gansu province, northwestern China) were studied by magnetic and geochemical analyses. The results showed that magnetic susceptibility was enhanced near industrial areas, and PSD-MD magnetite dominated the magnetic properties. Magnetic concentration parameters (χlf, SIRM, and χARM) showed different correlations with heavy metals and PLI in the three cities, indicating significantly different magnetic response to different pollution sources. Principal component analysis showed that ferrimagnetic minerals coexist with heavy metals of Fe, As, Cu, Pb, and Zn in Baiyin and Fe, V, Cu, Mn, Pb, and Cr in Jiayuguan. Fuzzy cluster analysis and regression analysis further indicated that the sensitivity of magnetic monitoring to fuel dust is higher than that to mineral dust near non-ferrous metal smelters, and fossil fuel consumption is an important factor for increasing magnetite content. In all the three cities, the sensitivity of magnetic monitoring to pollutants from steel plants is much higher than that from non-ferrous metal plants. Therefore, magnetic proxies provide a rapid means for detecting heavy metal contamination caused by multi-anthropogenic pollution sources in a large scale area, however, the sensitivity was controlled by pollution sources. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Time-resolved luminescence measurements of the magnetic field effect on paramagnetic photosensitizers in photodynamic reactions

    Science.gov (United States)

    Mermut, O.; Bouchard, J.-P.; Cormier, J.-F.; Desroches, P.; Diamond, K. R.; Fortin, M.; Gallant, P.; Leclair, S.; Marois, J.-S.; Noiseux, I.; Morin, J.-F.; Patterson, M. S.; Vernon, M.

    2008-02-01

    The development of multimodal molecular probes and photosensitizing agents for use in photodynamic therapy (PDT) is vital for optimizing and monitoring cytotoxic responses. We propose a combinatorial approach utilizing photosensitizing molecules that are both paramagnetic and luminescent with multimodal functionality to perturb, control, and monitor molecular-scale reaction pathways in PDT. To this end, a time-domain single photon counting lifetime apparatus with a 400 nm excitation source has been developed and integrated with a variable low field magnet (0- 350mT). The luminescence lifetime decay function was measured in the presence of a sweeping magnetic field for a custom designed photosensitizing molecule in which photoinduced electron transfer was studied The photosensitizer studied was a donor-acceptor complex synthesized using a porphyrin linked to a fullerene molecule. The magneto-optic properties were investigated for the free-base photosensitizer complex as well as those containing either diamagnetic (paired electron) or paramagnetic (unpaired electron) metal centers, Zn(II) and Cu(II). The magnetic field was employed to affect and modify the spin states of radical pairs of the photosensitizing agents via magnetically induced hyperfine and Zeeman effects. Since the Type 1 reaction pathway of an excited triplet state photosensitizer involves the production of radical species, lifetime measurements were conducted at low dissolved oxygen concentration (0.01ppm) to elucidate the dependence of the magnetic perturbation on the photosensitization mechanistic pathway. To optimize the magnetic response, a solvent study was performed examining the dependence of the emission properties on the magnetic field in solutions of varying dielectric constants. Lastly, the cytotoxicity in murine tumor cell suspensions was investigated for the novel porphyrin-fullerene complex by inducing photodynamic treatments and determining the associated cell survival.

  15. Primary physical mechanism of different magnetic fields action on roots of some plants

    Directory of Open Access Journals (Sweden)

    N. V. Sheykina

    2017-12-01

    Full Text Available Background: Though the magnetic field action on biological object is proved now by many experiments it cannot be explained. The counterarguments are the small value of magnetic induction, that is effective for static magnetic field and the small value of ions free path length for ion cyclotron resonance presence.   Objectives of the article were to generalize all the results that had been obtained before in static, alternative and combined magnetic fields and to explain all results by one and the same primary physical mechanism. Materials and methods that were used to obtain experimental results were based on the using of well reproducible magnetic conditions. For this purpose 3 lays µ-metal shield and superconductive shield with warm volume were used. The artificial magnetic field was created in the shield. The objects of the investigation were roots of cress, maize and pea. Their gravitropic reaction was studied. Results and discussion: All experimental results were compared with the theories and calculations maid before and following from the three mechanisms proposed below.  It was shown that there were three physical primary mechanisms that could lead to effect of low frequency alternative and combined magnetic fields and permanent magnetic field on gravitropic reaction in plants. All of them depended on the relative location of roots, gravity and components of permanent and alternative magnetic fields between themselves. The first mechanism is based on the classic model of the rotation of ions in the plane that is perpendicular to the magnetic field direction or precession of magnetic moments round the direction of magnetic field vector. The second mechanism is connected with the piezoelectric properties of starch grain (porous piezoelectricity. This property of starch may create the change in the moving of starch grains in alternative and combined magnetic fields, and even in static one. The third mechanism is caused by the phase

  16. Polymeric reaction of polymer-monomer system for pressure sensitive adhesives by low energy electron beam

    International Nuclear Information System (INIS)

    Takiguchi, R.; Uryu, T.

    1985-01-01

    Application of low-energy electron beam to non-solvent type pressure sensitive adhesives is investigated. The adhesive properties such as peel strength and holding time (dead-load strength) were closely related to the reaction of acrylate polymer-monomer systems. The reaction behavior is elucidated by combining the measurement of gel fraction, infrared spectrum of gel, and the molecular weight distribution detected by gel permeation chromatography. It was important for the production of pressure sensitive adhesives by electron beam that the adhesive with high peel strength and long holding time is composed of a proper combination of three factors, that is, about 35% gel fraction, 25% monomer units in gel, and 15% graft efficiency by irradiating the polymer-monomer system containing low molecular weight poly (butyl acrylate). (author)

  17. TOTAL NUCLEAR-REACTION PROBABILITY OF 270 TO 390 N-14 IONS IN SI AND CSI

    NARCIS (Netherlands)

    WARNER, RE; CARPENTER, CL; FETTER, JM; WAITE, WF; WILSCHUT, HW; HOOGDUIN, JM

    A magnetic spectrograph and position-sensitive detectors were used to measure the total nuclear reaction probability eta(R) for alpha + CsI at 116 MeV, N-14 + CsI at 265 and 385 MeV, and N-14 + Si at 271 and 390 MeV. From these eta(R)'s, average reaction cross sections sigma(R) were deduced for

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... comfortable clothing and leave any jewelry at home. Tell the radiologic technologist if you have medical devices implanted in your body as these can interfere with the magnetic field ...

  19. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    Science.gov (United States)

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  20. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics

    Directory of Open Access Journals (Sweden)

    Haiyun Huang

    2015-10-01

    Full Text Available This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  1. Nano-organocatalyst: magnetically retrievable ferrite-anchored glutathione for microwave-assisted Paal–Knorr reaction, aza-Michael addition, and pyrazole synthesis

    KAUST Repository

    Polshettiwar, Vivek; Varma, Rajender S.

    2010-01-01

    Postsynthetic Surface modification of magnetic nanoparticles by glutathione imparts desirable chemical functionality and enables the generation of catalytic sites on the surfaces of ensuing organocatalysts. In this article, we discuss the developments, unique activity, and high selectivity of nano-organocatalysts for microwave-assisted Paal-Knorr reaction, aza-Michael addition, and pyrazole synthesis. Their insoluble character Coupled with paramagnetic nature enables easy separation of these nano-catalysts from the reaction mixture using external magnet, which eliminates the requirement of catalyst filtration. Published by Elsevier Ltd.

  2. A Magnetic Tracking System based on Highly Sensitive Integrated Hall Sensors

    Science.gov (United States)

    Schlageter, Vincent; Drljaca, Predrag; Popovic, Radivoje S.; KuČERA, Pavel

    A tracking system with five degrees of freedom based on a 2D-array of 16 Hall sensors and a permanent magnet is presented in this paper. The sensitivity of the Hall sensors is increased by integrated micro- and external macro-flux-concentrators. Detection distance larger than 20cm (during one hour without calibration) is achieved using a magnet of 0.2cm3. This corresponds to a resolution of the sensors of 0.05µTrms. The position and orientation of the marker is displayed in real time at least 20 times per second. The sensing system is small enough to be hand-held and can be used in a normal environment. This presented tracking system has been successfully applied to follow a small swallowed magnet through the entire human digestive tube. This approach is extremely promising as a new non-invasive diagnostic technique in gastro-enterology.

  3. Sensitive parameters' optimization of the permanent magnet supporting mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yongguang; Gao, Xiaohui; Wang, Yixuan; Yang, Xiaowei [Beihang University, Beijing (China)

    2014-07-15

    The fast development of the ultra-high speed vertical rotor promotes the study and exploration for the supporting mechanism. It has become the focus of research that how to improve the speed and overcome the vibration when the rotors pass through the low-order critical frequencies. This paper introduces a kind of permanent magnet (PM) supporting mechanism and describes an optimization method of its sensitive parameters, which can make the vertical rotor system reach 80000 r/min smoothly. Firstly we find the sensitive parameters through analyzing the rotor's features in the process of achieving high-speed, then, study these sensitive parameters and summarize the regularities with the method of combining the experiment and the finite element method (FEM), at last, achieve the optimization method of these parameters. That will not only get a stable effect of raising speed and shorten the debugging time greatly, but also promote the extensive application of the PM supporting mechanism in the ultra-high speed vertical rotors.

  4. Sensitivity of sediment magnetic records to climate change during Holocene for the northern South China Sea

    Science.gov (United States)

    Ouyang, Tingping; Li, Mingkun; Zhao, Xiang; Zhu, Zhaoyu; Tian, Chengjing; Qiu, Yan; Peng, Xuechao; Hu, Qiao

    2016-05-01

    Magnetic property has been proved to be a sensitive proxy to climate change for both terrestrial and marine sediments. Based on the schedule frame established by AMS 14C dating of foraminifera, detail magnetic analyses were performed for core PC24 sediments at sampling intervals of 2 cm to discuss magnetic sensitivity of marine sediment to climate during Holocene for the northern South China Sea. The results indicated that: 1) Concentration dependent magnetic parameters are positive corresponding to variation of temperature. The frequency dependent susceptibility coefficient basically reflected the variation in humidity; 2) XARM/SIRM was more sensitive to detrital magnetite particles and SIRM/X was more effective to biogenic magnetite particles. Variations of XARM/SIRM and SIRM/X are corresponding to precipitation and temperature, respectively; 3) the Holocene Megathermal in the study area was identified as 7.5-3.4 cal. ka BP. The warmest stage of Holocene for the study area should be during 6.1 to 3.9 cal. ka BP; 4) The 8 ka cold event was characterized as cold and dry during 8.55 to 8.25 cal. ka BP; 5) During early and middle Holocene, the climate combinations were warm dry and cold wet. It turned to warm and wet after 2.7 cal. ka BP.

  5. Sensitivity of sediment magnetic records to climate change during Holocene for the northern South China Sea

    Directory of Open Access Journals (Sweden)

    Tingping eOuyang

    2016-05-01

    Full Text Available Magnetic property has been proved to be a sensitive proxy to climate change for both terrestrial and marine sediments. Based on the schedule frame established by AMS 14C dating of foraminifera, detail magnetic analyses were performed for core PC24 sediments at sampling intervals of 2 cm to discuss magnetic sensitivity of marine sediment to climate during Holocene for the northern South China Sea. The results indicated that: 1 Concentration dependent magnetic parameters are positive corresponding to variation of temperature. The frequency dependent susceptibility coefficient basically reflected the variation in humidity; 2 XARM/SIRM was more sensitive to detrital magnetite particles and SIRM/X was more effective to biogenic magnetite particles. Variations of XARM/SIRM and SIRM/X are corresponding to precipitation and temperature, respectively; 3 the Holocene Megathermal in the study area was identified as 7.5-3.4 cal. ka BP. The warmest stage of Holocene for the study area should be during 6.1 to 3.9 cal. ka BP; 4 The 8 ka cold event was characterized as cold and dry during 8.55 to 8.25 cal. ka BP; 5 During early and middle Holocene, the climate combinations were warm dry and cold wet. It turned to warm and wet after 2.7 cal. ka BP.

  6. Solvent dependence of organic exciplex fluorescence studied by magnetic effect on reaction yield (M.A.R.Y) spectroscopy

    International Nuclear Information System (INIS)

    Pal, K.

    2011-01-01

    This work aims at understanding the various facets of one of the elementary reactions in nature, the electron transfer reaction using MARY (Magnetic effect on Reaction Yield) spectroscopy as a tool. The prime focus of study by the use this technique was the solvent dependence of organic exciplex fluorescence. Apart from that temperature dependent measurements using MARY spectroscopy have been performed to extract the activation energy parameters of electron transfer reaction. The discovery of magnetic field effect on new system was also a part of our study. The study of solvent dependence of organic exciplex fluorescence using MARY spectroscopy was carried out on the system of 9,10-dimethylanthracene (as the fluorophore) and N,N'-dimethylaniline and 4,4'-Bis(dimethylamino) diphenylmethane (as quenchers) in binary solvent mixtures of toluene/dimethylsulfoxide, benzylacetate/dimethylsulfoxide, toluene/propylenecarbonate and propylacetate/butyronitrile. The work focuses on the use of solvent mixtures rather than pure solvents. The solvent mixtures, tailored to simulate different microenvironemets, were employed to find out the effect of preferential solvation on electron transfer reaction. The contrast in the absolute field effect and linewidth values of the MARY spectra obtained in the four system as a function of dielectric constant scan suggest the imperative effect of concentration fluctuation on the electron transfer reaction. Temperature dependent measurements were performed on the system of N,N,N',N'- tetramethylparaphenylendiamin, photo-ionizing in a mixture of toluene/dimethylsulfoxide. However the sluggish response of the system to temperature changes does not really permit us to extract fruitful results. The magnetic field effect on the much studied system of Perylene/ N.N'-dimethylaniline was discovered for the first time. (author) [de

  7. Sensitivity Enhancement of a Vertical-Type CMOS Hall Device for a Magnetic Sensor

    Directory of Open Access Journals (Sweden)

    Sein Oh

    2018-01-01

    Full Text Available This study presents a vertical-type CMOS Hall device with improved sensitivity to detect a 3D magnetic field in various types of sensors or communication devices. To improve sensitivity, trenches are implanted next to the current input terminal, so that the Hall current becomes maximum. The effect of the dimension and location of trenches on sensitivity is simulated in the COMSOL simulator. A vertical-type Hall device with a width of 16 μm and a height of 2 μm is optimized for maximum sensitivity. The simulation result shows that it has a 23% better result than a conventional vertical-type CMOS Hall device without a trench.

  8. Sensitivity of the magnetization curves of different austenitic stainless tube and pipe steels to mechanical fatigue

    International Nuclear Information System (INIS)

    Niffenegger, M.; Leber, H.J.

    2008-01-01

    In meta-stable austenitic stainless steels, fatigue is accompanied by a partial strain-induced transformation of paramagnetic austenite to ferromagnetic martensite [G.B. Olsen, M. Cohen, Kinetics of strain induced martensite nucleation, Metall. Trans. 6 (1975) 791-795]. The associated changes of magnetic properties as the eddy current impedance, magnetic permeability or the remanence field may serve as an indication for the degree of fatigue and therefore the remaining lifetime of a component, even though the exact causal relationship between martensite formation and fatigue is not fully understood. However, measuring these properties by magnetic methods may be limited by the low affinity for strain-induced martensite formation. Thus other methods have to be found which are able to detect very small changes of ferromagnetic contents. With this aim the influence of cyclic strain loading on the magnetization curves of the austenitic stainless tube and pipe steels TP 321, 347, 304L and 316L is analysed in the present paper. The measured characteristic magnetic properties, which are the saturation magnetization, residual magnetization, coercive field and the field dependent permeability (AC-magnetization), are sensitive to fatigue and the corresponding material changes (martensitic transformation). In particular, the AC-magnetization was found to be very sensitive to small changes of the amount of strain induced martensite and therefore also to the degree of fatigue. Hence we conclude that applying magnetic minor loops are promising for the non-destructive evaluation of fatigue in austenitic stainless steel, even if a very small amount of strain induced martensite is formed

  9. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  10. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... that uses a powerful magnetic field and a computer to produce detailed pictures of the major blood ... Your Medical Images Movement Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by ...

  11. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... an MRA scan, there are several things you can do to prepare for the examination. First of ... medical devices implanted in your body as these can interfere with the magnetic field of the MRI ...

  12. Noise sensitivity and diminished health: Testing moderators and mediators of the relationship

    Directory of Open Access Journals (Sweden)

    Erin M Hill

    2014-01-01

    Full Text Available The concept of noise sensitivity emerged in public health and psychoacoustic research to help explain individual differences in reactions to noise. Noise sensitivity has been associated with health problems, but the mechanisms underlying this relationship have yet to be fully examined. Participants (n = 1102 were residents of Auckland, New Zealand, who completed questionnaires and returned them through the post. Models of noise sensitivity and health were tested in the analyses using bootstrapping methods to examine indirect effects. Results indicated that gender and noise exposure were not significant moderators in the model. Perceived stress and sleep problems were significant mediators of the relationship between noise sensitivity and subjective health complaints, even after controlling for the influence of neuroticism. However, the relationship between noise sensitivity and mental health complaints (anxiety and depression was accounted for by the variance explained by neuroticism. Overall, this study provides considerable understanding of the relationship between noise sensitivity and health problems and identifies areas for further research in the field.

  13. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... it’s commonly known, MRA. MRA is a noninvasive test that uses a powerful magnetic field and a computer to produce detailed pictures of the major blood vessels throughout your body. It may be performed ...

  15. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  16. DC magnetic field sensing based on the nonlinear magnetoelectric effect in magnetic heterostructures

    International Nuclear Information System (INIS)

    Burdin, Dmitrii; Chashin, Dmitrii; Ekonomov, Nikolai; Fetisov, Leonid; Fetisov, Yuri; Shamonin, Mikhail

    2016-01-01

    Recently, highly sensitive magnetic field sensors using the magnetoelectric effect in composite ferromagnetic-piezoelectric layered structures have been demonstrated. However, most of the proposed concepts are not useful for measuring dc magnetic fields, because the conductivity of piezoelectric layers results in a strong decline of the sensor’s sensitivity at low frequencies. In this paper, a novel functional principle of magnetoelectric sensors for dc magnetic field measurements is described. The sensor employs the nonlinear effect of voltage harmonic generation in a composite magnetoelectric structure under the simultaneous influence of a strong imposed ac magnetic field and a weak dc magnetic field to be measured. This physical effect arises due to the nonlinear dependence of the magnetostriction in the ferromagnetic layer on the magnetic field. A sensor prototype comprising of a piezoelectric fibre transducer sandwiched between two layers of the amorphous ferromagnetic Metglas ® alloy was fabricated. The specifications regarding the magnetic field range, frequency characteristics, and noise level were studied experimentally. The prototype showed the responsivity of 2.5 V mT −1 and permitted the measurement of dc magnetic fields in the range of ∼10 nT to about 0.4 mT. Although sensor operation is based on the nonlinear effect, the sensor response can be made linear with respect to the measured magnetic field in a broad dynamic range extending over 5 orders of magnitude. The underlying physics is explained through a simplified theory for the proposed sensor. The functionality, differences and advantages of the magnetoelectric sensor compare well with fluxgate magnetometers. The ways to enhance the sensor performance are considered. (paper)

  17. Victimization Experiences and the Stabilization of Victim Sensitivity

    Directory of Open Access Journals (Sweden)

    Mario eGollwitzer

    2015-04-01

    Full Text Available People reliably differ in the extent to which they are sensitive to being victimized by others. Importantly, victim sensitivity predicts how people behave in social dilemma situations: Victim-sensitive individuals are less likely to trust others and more likely to behave uncooperatively - especially in socially uncertain situations. This pattern can be explained with the Sensitivity to Mean Intentions (SeMI model, according to which victim sensitivity entails a specific and asymmetric sensitivity to contextual cues that are associated with untrustworthiness. Recent research is largely in line with the model’s prediction, but some issues have remained conceptually unresolved so far. For instance, it is unclear why and how victim sensitivity becomes a stable trait and which developmental and cognitive processes are involved in such stabilization. In the present article, we will discuss the psychological processes that contribute to a stabilization of victim sensitivity within persons, both across the life span (ontogenetic stabilization and across social situations (actual-genetic stabilization. Our theoretical framework starts from the assumption that experiences of being exploited threaten a basic need, the need to trust. This need is so fundamental that experiences that threaten it receive a considerable amount of attention and trigger strong affective reactions. Associative learning processes can then explain (a how certain contextual cues (e.g., facial expressions become conditioned stimuli that elicit equally strong responses, (b why these contextual untrustworthiness cues receive much more attention than, for instance, trustworthiness cues, and (c how these cues shape spontaneous social expectations (regarding other people’s intentions. Finally, avoidance learning can explain why these cognitive processes gradually stabilize and become a trait: the trait which is referred to as victim sensitivity.

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... it’s commonly known, MRA. MRA is a noninvasive test that uses a powerful magnetic field and a ...

  19. Magnetophoretic potential at the movement of cluster products of electrochemical reactions in an inhomogeneous magnetic field

    International Nuclear Information System (INIS)

    Gorobets, O. Yu.; Gorobets, Yu. I.; Rospotniuk, V. P.

    2015-01-01

    An electric field arises from the influence of a nonuniform static magnetic field on charged colloid particles with magnetic susceptibility different from that of the surrounding liquid. It arises, for example, under the influence of a nonuniform static magnetic field in clusters of electrochemical reaction products created during metal etching, deposition, and corrosion processes without an external electric current passing through an electrolyte near a magnetized electrode surface. The corresponding potential consists of a Nernst potential of inhomogeneous distribution of concentration of colloid particles and a magnetophoretic potential (MPP). This potential has been calculated using a thermodynamic approach based on the equations of thermodynamics of nonequilibrium systems and the Onsager relations for a mass flow of correlated magnetic clusters under a gradient magnetic force in the electrolyte. The conditions under which the MPP contribution to the total electric potential may be significant are discussed with a reference to the example of a corroding spherical ferromagnetic steel electrode

  20. Magnetophoretic potential at the movement of cluster products of electrochemical reactions in an inhomogeneous magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Gorobets, O. Yu., E-mail: pitbm@ukr.net; Gorobets, Yu. I., E-mail: Gorobets@imag.kiev.ua [National Technical University of Ukraine “KPI”, Peremogy Avenue 37, Kyiv 03056 (Ukraine); Institute of Magnetism NAS of Ukraine and National Academy of Sciences of Ukraine, Vernadsky Avenue, 36-b, Kyiv 03142 (Ukraine); Rospotniuk, V. P. [National Technical University of Ukraine “KPI”, Peremogy Avenue 37, Kyiv 03056 (Ukraine)

    2015-08-21

    An electric field arises from the influence of a nonuniform static magnetic field on charged colloid particles with magnetic susceptibility different from that of the surrounding liquid. It arises, for example, under the influence of a nonuniform static magnetic field in clusters of electrochemical reaction products created during metal etching, deposition, and corrosion processes without an external electric current passing through an electrolyte near a magnetized electrode surface. The corresponding potential consists of a Nernst potential of inhomogeneous distribution of concentration of colloid particles and a magnetophoretic potential (MPP). This potential has been calculated using a thermodynamic approach based on the equations of thermodynamics of nonequilibrium systems and the Onsager relations for a mass flow of correlated magnetic clusters under a gradient magnetic force in the electrolyte. The conditions under which the MPP contribution to the total electric potential may be significant are discussed with a reference to the example of a corroding spherical ferromagnetic steel electrode.

  1. Jitter reduction of a reaction wheel by management of angular momentum using magnetic torquers in nano- and micro-satellites

    Science.gov (United States)

    Inamori, Takaya; Wang, Jihe; Saisutjarit, Phongsatorn; Nakasuka, Shinichi

    2013-07-01

    Nowadays, nano- and micro-satellites, which are smaller than conventional large satellites, provide access to space to many satellite developers, and they are attracting interest as an application of space development because development is possible over shorter time period at a lower cost. In most of these nano- and micro-satellite missions, the satellites generally must meet strict attitude requirements for obtaining scientific data under strict constraints of power consumption, space, and weight. In many satellite missions, the jitter of a reaction wheel degrades the performance of the mission detectors and attitude sensors; therefore, jitter should be controlled or isolated to reduce its effect on sensor devices. In conventional standard-sized satellites, tip-tilt mirrors (TTMs) and isolators are used for controlling or isolating the vibrations from reaction wheels; however, it is difficult to use these devices for nano- and micro-satellite missions under the strict power, space, and mass constraints. In this research, the jitter of reaction wheels is reduced by using accurate sensors, small reaction wheels, and slow rotation frequency reaction wheel instead of TTMs and isolators. The objective of a reaction wheel in many satellite missions is the management of the satellite's angular momentum, which increases because of attitude disturbances. If the magnitude of the disturbance is reduced in orbit or on the ground, the magnitude of the angular momentum that the reaction wheels gain from attitude disturbances in orbit becomes smaller; therefore, satellites can stabilize their attitude using only smaller reaction wheels or slow rotation speed, which cause relatively smaller vibration. In nano- and micro-satellite missions, the dominant attitude disturbance is a magnetic torque, which can be cancelled by using magnetic actuators. With the magnetic compensation, the satellite reduces the angular momentum that the reaction wheels gain, and therefore, satellites do

  2. Structure sensitive reactions over Co, Fe and mixed metal clusters in zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Suib, S.L.

    1992-08-01

    Transient and steady state kinetic studies of structure sensitive reactions of cyclopropane (c-C{sub 3}H{sub 6}) and hydrogen over zeolites is the first area of this studied. Low level impurity Fe{sup 3+} ions in zeolites complicate interpretation of spectroscopic and catalytic studies of these systems. We focused our efforts on selectively substituting Fe{sup 3+} ions in the frameworks of various zeolites to understand their role in catalytic reactions such as with c-C{sub 3}H{sub 6} and H{sub 2}. These studies led to isomorphous substitution of other ions like B{sup 3+} and their use in isomerization of n-butenes to isobutylene. The third area of research involves the synthesis, characterization and catalysis of a new class of molecular sieve manganese oxide tunnel structure materials.

  3. High sensitivity zero-biased magnetic field sensor based on multiphase laminate heterostructures with FeCuNbSiB nanocrystalline soft magnetic alloy

    Science.gov (United States)

    Qiu, Jing; Wen, Yumei; Li, Ping; Chen, Hengjia

    2016-05-01

    In this paper, a high sensitivity zero-biased magnetic field sensor based on multiphase laminate heterostructures consisting of FeCuNbSiB/Terfenol-D (Tb1-xDyxFe2)/PZT (Pb(Zr1-x,Tix)O3)/Terfenol-D/PZT/Ternol-D/FeCuNbSiB (FMPMPMF) is presented, whose ME coupling characteristics and sensing performances have been investigated. Compared to traditional Terfenol-D/PZT/Terfenol-D (MPM) and Terfenol-D/PZT/Terfenol-D/PZT/Terfenol-D (MPMPM) sensors, the zero-biased ME coupling characteristics of FMPMPMF sensor were significantly improved, owing to a build-in magnetic field in FeCuNbSiB/Terfenol-D layers. The optimum zero-biased resonant ME voltage coefficient of 3.02 V/Oe is achieved, which is 1.65 times as great as that of MPMPM and 2.51 times of MPM sensors. The mean value of low-frequency ME field coefficient of FMPMPMF reaches 122.53 mV/cm Oe, which is 2.39 times as great as that of MPMPM and 1.79 times of MPM sensors. Meanwhile, the induced zero-biased ME voltage of FMPMPMF sensor shows an excellent linear relationship to ac magnetic field both at the low frequency (1 kHz) and the resonant frequency (106.6 kHz). Remarkably, it indicates that the proposed zero-biased magnetic field sensor give the prospect of being able to applied to the field of highly sensitive ac magnetic field sensing.

  4. Driving higher magnetic field sensitivity of the martensitic transformation in MnCoGe ferromagnet

    Science.gov (United States)

    Ma, S. C.; Ge, Q.; Hu, Y. F.; Wang, L.; Liu, K.; Jiang, Q. Z.; Wang, D. H.; Hu, C. C.; Huang, H. B.; Cao, G. P.; Zhong, Z. C.; Du, Y. W.

    2017-11-01

    The sharp metamagnetic martensitic transformation (MMT) triggered by a low critical field plays a pivotal role in magnetoresponsive effects for ferromagnetic shape memory alloys (FSMAs). Here, a sharper magnetic-field-induced metamagnetic martensitic transformation (MFIMMT) is realized in Mn1-xCo1+xGe systems with a giant magnetocaloric effect around room temperature, which represents the lowest magnetic driving and completion fields as well as the largest magnetization difference around MFIMMT reported heretofore in MnCoGe-based FSMAs. More interestingly, a reversible MFIMMT with field cycling is observed in the Mn0.965Co0.035Ge compound. These results indicate that the consensus would be broken that the magnetic field is difficult to trigger the MMT for MnCoGe-based systems. The origin of a higher degree of sensitivity of martensitic transformation to the magnetic field is discussed based on the X-ray absorption spectroscopic results.

  5. Two dimensional magnetic field calculations for the SSC dipole magnets

    International Nuclear Information System (INIS)

    Krefta, M.P.; Pavlik, D.

    1991-01-01

    In this work two-dimensional methods are used to calculate the magnetic fields throughout the cross section of a SSC dipole magnet. Analytic techniques, which are based on closed form solutions to the defining field equations, are used to calculate the multipole content for any specified conductor positioning. The method is extended to investigate the effects of radial slots or keyways in the iron yoke. The multipole components of field, directly attributable to the slots or keyways, are examined as a function of size and location. It is shown that locating the slots or keyways at the magnet pole centers has a large effect on the multipole components; whereas, locating the keyways between the magnet poles has little effect on any of the multipoles. The investigation of nonlinear effects such as ferromagnetic saturation or superconductor magnetization relies on the use of numerical methods such as the finite element method. The errors associated with these codes are explained in terms of numerical round-off, spatial discretization error and the representation of distant boundaries. A method for increasing the accuracy of the multipole calculation from finite element solutions is set forth. It is shown that calculated multipole coefficients are sensitive to boundary conditions external to the cold mass during conditions of magnetic saturation

  6. Combining magnetic nanoparticle with biotinylated nanobodies for rapid and sensitive detection of influenza H3N2

    Science.gov (United States)

    Zhu, Min; Hu, Yonghong; Li, Guirong; Ou, Weijun; Mao, Panyong; Xin, Shaojie; Wan, Yakun

    2014-09-01

    Our objective is to develop a rapid and sensitive assay based on magnetic beads to detect the concentration of influenza H3N2. The possibility of using variable domain heavy-chain antibodies (nanobody) as diagnostic tools for influenza H3N2 was investigated. A healthy camel was immunized with inactivated influenza H3N2. A nanobody library of 8 × 108 clones was constructed and phage displayed. After three successive biopanning steps, H3N2-specific nanobodies were successfully isolated, expressed in Escherichia coli, and purified. Sequence analysis of the nanobodies revealed that we possessed four classes of nanobodies against H3N2. Two nanobodies were further used to prepare our rapid diagnostic kit. Biotinylated nanobody was effectively immobilized onto the surface of streptavidin magnetic beads. The modified magnetic beads with nanobody capture specifically influenza H3N2 and can still be recognized by nanobodies conjugated to horseradish peroxidase (HRP) conjugates. Under optimized conditions, the present immunoassay exhibited a relatively high sensitive detection with a limit of 50 ng/mL. In conclusion, by combining magnetic beads with specific nanobodies, this assay provides a promising influenza detection assay to develop a potential rapid, sensitive, and low-cost diagnostic tool to screen for influenza infections.

  7. Unequal diffusivities case of homogeneous–heterogeneous reactions within viscoelastic fluid flow in the presence of induced magnetic-field and nonlinear thermal radiation

    Directory of Open Access Journals (Sweden)

    I.L. Animasaun

    2016-06-01

    Full Text Available This article presents the effects of nonlinear thermal radiation and induced magnetic field on viscoelastic fluid flow toward a stagnation point. It is assumed that there exists a kind of chemical reaction between chemical species A and B. The diffusion coefficients of the two chemical species in the viscoelastic fluid flow are unequal. Since chemical species B is a catalyst at the horizontal surface, hence homogeneous and heterogeneous schemes are of the isothermal cubic autocatalytic reaction and first order reaction respectively. The transformed governing equations are solved numerically using Runge–Kutta integration scheme along with Newton’s method. Good agreement is obtained between present and published numerical results for a limiting case. The influence of some pertinent parameters on skin friction coefficient, local heat transfer rate, together with velocity, induced magnetic field, temperature, and concentration profiles is illustrated graphically and discussed. Based on all of these assumptions, results indicate that the effects of induced magnetic and viscoelastic parameters on velocity, transverse velocity and velocity of induced magnetic field are almost the same but opposite in nature. The strength of heterogeneous reaction parameter is very helpful to reduce the concentration of bulk fluid and increase the concentration of catalyst at the surface.

  8. Is non-response to fluconazole maintenance therapy for recurrent Candida vaginitis related to sensitization to atopic reactions?

    Science.gov (United States)

    Donders, Gilbert G G; Grinceviciene, Svitrigaile; Bellen, Gert; Jaeger, Martin; Ten Oever, Jaap; Netea, Mihai G

    2018-04-01

    Is sensitization to atopic reaction related to treatment response of recurrent Candida vulvovaginal (RVVC)? Analysis of ReCiDiF trial data of optimal (OR) and non-responders (NR) to fluconazole maintenance treatment, to explore medical history, physical status, family history, and vaginal immune response for potential sensitization to atopic reaction. Sociodemographic characteristics of 33 NR women were not different from 38 OR. NR had received higher number of different treatments (mean difference 1.6 different treatments (95% CI: 0.20-2.97), P = .03) and had more episodes of disease (P predictive factor for non-response in multivariate analysis with specificity 77.8% and sensitivity 51.6%. Women with RVVC with vulvar excoriation, longer duration of disease, and family history of atopic disease are at increased risk not to respond to maintenance fluconazole treatment. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Permanent-Magnet Free Biasing of MR Sensors with Tunable Sensitivity

    Science.gov (United States)

    Halloran, Sean; Dasilva, Fabio; Pappas, David

    2007-03-01

    Exchange coupling^1 has been previously observed in a trilayer structure of ferromagnet (FM)/non-magnetic/antiferromagnet (AFM) and the exchange bias was found to be a function of the thickness of the buffer layer.^2,3,4 This unique coupling is used as a stabilizing bias for the sense layer with the additional ability to tailor the magnetic gain of the sensor for various applications. The elimination of permanent magnet bias results in the elimination of one patterning and one deposition step. Ruthenium (Ru) is used as the buffer layer and is self aligned with the FM and AFM layers and the thickness is varied to change the slope of the transfer curve in the linear region. Sensor devices are fabricated with a bipolar output, a medium sensitivity, and a wide field range. The results show that this biasing scheme is well suited for barber pole and soft adjacent layer (SAL) anisotropic magnetoresistance (AMR) stripes used in magnetic field sensors with a FM layer of Permalloy (NiFe) and an AFM layer of Iridium-Manganese (IrMn). Applications include a 256 channel read head used for magnetic forensics. 1N.J. Gokemeijer, T. Ambrose, C.L. Chien, N. Wang and K.K. Fung, J. Appl. Phys. 81 (8), 4999, 15 April 1997. 2W.H. Meiklejohn and C.P. Bean, Phys. Rev. 102, 1413 1956; 105, 904, 1957. 3L. Thomas, A.J. Kellock and S.S.P. Parkin, J. Appl. Phys. 87 (9), 5061, 1 May 2000. 4D. Wang, J. Daughton, C. Nordman, P. Eames and J. Fink, J. Appl. Phys. 99, 2006.

  10. Fast and sensitive medical diagnostic protocol based on integrating circular current lines for magnetic washing and optical detection of fluorescent magnetic nanobeads

    Directory of Open Access Journals (Sweden)

    Jaiyam Sharma

    2016-07-01

    Full Text Available Magnetic nanoparticles (MNPs are increasingly being used as ‘magnetic labels’ in medical diagnostics. Practical applications of MNPs necessitate reducing their non-specific interactions with sensor surfaces that result in noise in measurements. Here we describe the design and implementation of a sensing platform that incorporates circular shaped current lines that reduce non-specific binding by enabling the “magnetic washing” of loosely attached MNPs attached to the senor surface. Generating magnetic fields by passing electrical currents through the circular shaped current lines enabled the capture and collection of fluorescent MNPs that was more efficient and effective than straight current lines reported to-date. The use of fluorescent MNPs allows their optical detection rather than with widely used magnetoresistive sensors. As a result our approach is not affected by magnetic noise due to the flow of currents. Our design is expected to improve the speed, accuracy, and sensitivity of MNPs based medical diagnostics. Keywords: Biosensors, Magnetic beads, Fluorescent magnetic nanoparticles, Lab on chip, Point of care testing

  11. Magnetic substate populations of product nuclei in the /sup 11/B(d,p)/sup 12/B reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, M; Ochi, S; Minamisono, T; Mizobuchi, A; Sugimoto, K [Osaka Univ., Toyonaka (Japan). Lab. of Nuclear Studies

    1976-05-31

    Magnetic substate populations of product nuclei in the /sup 11/B(d,p)/sup 12/B reaction have been measured in an energy range Esub(d) = 1.3-3.0 MeV at recoil angles of thetasub(R) = 55/sup 0/, 45/sup 0/ and 27/sup 0/-37/sup 0/. A static magnetic field (3 kG) was applied normal to the reaction plane to keep the nuclear orientation. Quadrupole effects on the implanted /sup 12/B in Ta were utilized to perturb the Zeeman splitting. NMR transitions were induced, and detected by the asymmetry change in the ..beta..-decay of /sup 12/B. From this information, the magnetic substate populations were determined, for the unique assignment of which the sign of the quadrupole interaction had to be known. For this purpose, a p-..gamma.. angular correlation was measured, which determined the alignment of the first excited state of /sup 12/B. A comparison of the present result with theoretical predictions is given, together with the resultant information about j-mixings in the /sup 12/B states.

  12. Synthesis and characterization of NiFe2O4–Pd magnetically recyclable catalyst for hydrogenation reaction

    International Nuclear Information System (INIS)

    Karaoğlu, E.; Özel, U.; Caner, C.; Baykal, A.; Summak, M.M.; Sözeri, H.

    2012-01-01

    Graphical abstract: Display Omitted Highlights: ► Novel superparamagnetic NiFe 2 O 4 –Pd magnetically recyclable catalyst was fabricated through co-precipitation. ► It could be reused several times without significant loss in catalytic activity for hydrogenation reaction. ► No further modification of the NiFe 2 O 4 –Pd magnetically recyclable catalyst is necessary for utilization as catalyst. -- Abstract: Herein we report the fabrication and characterization magnetically recyclable catalysts of NiFe 2 O 4 –Pd nanocomposite as highly effective catalysts for reduction reactions in liquid phase. The reduction Pd 2+ was accomplished with polyethylene glycol 400 (PEG-400) instead of sodium borohydride (NaBH 4 ) and NiFe 2 O 4 nanoparticles was prepared by sonochemically using FeCI 3 ·6H 2 O and NiCl 2 . The chemical characterization of the product was done with X-ray diffractometry, Infrared spectroscopy, transmission electron microscopy, UV–Vis spectroscopy, thermal gravimetry and inductively coupled plasma. Thus formed NiFe 2 O 4 –Pd MRCs showed a very high activity in reduction reactions of 4-nitro aniline and 1,3-dinitrobenzene in liquid phase. It was found out that the catalytic activity of NiFe 2 O 4 –Pd MRCs on the reduction of 4-nitro aniline and 1,3-dinitrobenzene in liquid phase are between 99–93% and 98–93%, respectively. Magnetic character of this system allowed recovery and multiple use without significant loss of its catalytic activity. It is found that NiFe 2 O 4 –Pd MRCs showed very efficient catalytic activity and multiple usability.

  13. The loss rates of O+ in the inner magnetosphere caused by both magnetic field line curvature scattering and charge exchange reactions

    Science.gov (United States)

    Ji, Y.; Shen, C.

    2014-03-01

    With consideration of magnetic field line curvature (FLC) pitch angle scattering and charge exchange reactions, the O+ (>300 keV) in the inner magnetosphere loss rates are investigated by using an eigenfunction analysis. The FLC scattering provides a mechanism for the ring current O+ to enter the loss cone and influence the loss rates caused by charge exchange reactions. Assuming that the pitch angle change is small for each scattering event, the diffusion equation including a charge exchange term is constructed and solved; the eigenvalues of the equation are identified. The resultant loss rates of O+ are approximately equal to the linear superposition of the loss rate without considering the charge exchange reactions and the loss rate associated with charge exchange reactions alone. The loss time is consistent with the observations from the early recovery phases of magnetic storms.

  14. Radiation sensitivity of mammalian cells

    International Nuclear Information System (INIS)

    Koch, C.J.

    1985-01-01

    The authors tested various aspects of the so-called ''competition'' model for radiation sensitization/protection. In this model, sensitizers and/or protectors react in first order chemical reactions with radiation-induced target radicals in the cell, producing damage fixation or repair respectively. It is only because of these parallel, first-order competing reactions that they may assign net amounts of damage on the basis of the chemical reactivity of the sentiziers/protectors with the radicals. It might be expected that such a simple model could not explain all aspects of cellular radiosensitivity and this has indeed been found to be true. However, one is able, with the simple model, to pose quite specific questions, and obtain quantitative information with respect to the relative agreement between experiment and theory. Many experiments by several investigators have found areas of disagreement with the competition theory, particularly with respect to the follow items: 1) role of cellular glutathione as the most important endogeneous radiation protector 2) characteristics of various sensitizers which cause them to behave differently from each other 3) methods relating to the quantitative kinetic analysis of experimenal results. This paper addresses these specific areas of disagreement from both an experimental and theoretical basis

  15. ¹⁹F magnetic resonance probes for live-cell detection of peroxynitrite using an oxidative decarbonylation reaction.

    Science.gov (United States)

    Bruemmer, Kevin J; Merrikhihaghi, Sara; Lollar, Christina T; Morris, Siti Nur Sarah; Bauer, Johannes H; Lippert, Alexander R

    2014-10-21

    We report a newly discovered oxidative decarbonylation reaction of isatins that is selectively mediated by peroxynitrite (ONOO(-)) to provide anthranilic acid derivatives. We have harnessed this rapid and selective transformation to develop two reaction-based probes, 5-fluoroisatin and 6-fluoroisatin, for the low-background readout of ONOO(-) using (19)F magnetic resonance spectroscopy. 5-fluoroisatin was used to non-invasively detect ONOO(-) formation in living lung epithelial cells stimulated with interferon-γ (IFN-γ).

  16. High temperature magnetic properties of Co(FeY){sub 2}O{sub 4} synthesized by combustion reaction

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Thiago Eduardo Pereira, E-mail: thiago.ifgo@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias (IFGO), Goiania (Brazil); Franco Junior, Adolfo [Universidade Federal de Goias (UFG), Goiania (Brazil)

    2016-07-01

    Full text: Cobalt ferrite is widely studied due to its interesting magnetic behavior at room temperature. However, many technical applications require temperatures that are above that. Thus, it is necessary to understand how some magnetic properties, such as saturation magnetization (Ms), remanent magnetization (Mr), and coercivity (Hc), may behave at high temperatures [1]. Among several methods to synthesize cobalt ferrites, combustion reaction method is intensively used because it is inexpensive, fast and has good control on the stoichiometry. This method is based on the chemistry of propellants and explosives [2]. Therefore, we have prepared a series of nanoparticles of CoFe{sub (2-x)}Y{sub x}O{sub 4}, with x ranging from 0.00 to 0.04, by combustion reaction method. The crystal structure and morphology were characterized by X-ray diffraction (XRD) using Rietveld refinement and transmission electron microscopy (TEM), respectively. Nanocrystalline particles structures in the typical phase of spinel were observed on diffractograms. Micrographies showed high crystalline powders for the particles and particles size within nanoscale range. The magnetic properties were measured by vibrating sample magnetometry (VSM) in broad range of temperature (300-850K). Saturation magnetization (Ms) decreases with Y doping increase, while Hc increases, being about 1.8 higher than the undoped sample. Furthermore, Curie temperature increases with Y doping increase. These magnetic properties were discussed in terms of the particle interactions induced by the thermal fluctuations, cation distribution, and ions exchange between yttrium and cobalt atoms in A-B sites in the cubic structure [3]. References: [1] A. Franco, Jr. and F. C. e Silva, Applied Physics Letters 96, 172505, (2010). 525 [2] S.R. Jain, et al, Combustion and flame 40, 71-79, (1981). [3] A. Franco Jr. et al. Journal of Alloys and Compounds 680, 198-205, (2016). (author)

  17. Ultra-High Field NMR and MRI—The Role of Magnet Technology to Increase Sensitivity and Specificity

    Directory of Open Access Journals (Sweden)

    Ewald Moser

    2017-08-01

    Full Text Available “History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors.” – P. J. Keating (former Australian Prime MinisterStarting with post-war developments in nuclear magnetic resonance (NMR a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (Nb-Ti based superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600–800 MHz (14.1–18.8 T up to 900 MHz (21 T at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development toward higher and higher field strength is a consequence of the inherently low

  18. Specialty magnets

    International Nuclear Information System (INIS)

    Halbach, K.

    1986-07-01

    A number of basic conceptual designs are explained for magnet systems that use permanent magnet materials. Included are iron free multipoles and hybrid magnets. Also appended is a discussion of the manufacturing process and magnetic properties of some permanent magnet materials

  19. Sensitivity of a search for cosmic ray sources including magnetic field effects

    Energy Technology Data Exchange (ETDEWEB)

    Urban, Martin; Erdmann, Martin; Mueller, Gero [III. Physikalisches Institut A, RWTH Aachen University (Germany)

    2016-07-01

    We analyze the sensitivity of a new method investigating correlations between ultra-high energy cosmic rays and extragalactic sources taking into account deflections in the galactic magnetic field. In comparisons of expected and simulated arrival directions of cosmic rays we evaluate the directional characteristics and magnitude of the field. We show that our method is capable of detecting anisotropy in data sets with a low signal fraction.

  20. Materials with low DC magnetic susceptibility for sensitive magnetic measurements

    International Nuclear Information System (INIS)

    Khatiwada, R; Kendrick, R; Khosravi, M; Peters, M; Smith, E; Snow, W M; Dennis, L

    2016-01-01

    Materials with very low DC magnetic susceptibility have many scientific applications. To our knowledge however, relatively little research has been conducted with the goal to produce a totally nonmagnetic material. This phrase in our case means after spatially averaging over macroscopic volumes, it possesses an average zero DC magnetic susceptibility. We report measurements of the DC magnetic susceptibility of three different types of nonmagnetic materials at room temperature: (I) solutions of paramagnetic salts and diamagnetic liquids, (II) liquid gallium–indium alloys and (III) pressed powder mixtures of tungsten and bismuth. The lowest measured magnetic susceptibility among these candidate materials is in the order of 10 −9 cgs volume susceptibility units, about two orders of magnitude smaller than distilled water. In all cases, the measured concentration dependence of the magnetic susceptibility is consistent with that expected for the weighted sum of the susceptibilities of the separate components within experimental error. These results verify the well-known Wiedemann additivity law for the magnetic susceptibility of inert mixtures of materials and thereby realize the ability to produce materials with small but tunable magnetic susceptibility. For our particular scientific application, we are also looking for materials with the largest possible number of neutrons and protons per unit volume. The gallium–indium alloys fabricated and measured in this work possess to our knowledge the smallest ratio of volume magnetic susceptibility to nucleon number density per unit volume for a room temperature liquid, and the tungsten-bismuth pressed powder mixtures possess to our knowledge the smallest ratio of volume magnetic susceptibility to nucleon number density per unit volume for a room temperature solid. This ratio is a figure of merit for a certain class of precision experiments that search for possible exotic spin-dependent forces of Nature. (paper)

  1. Derivation of the reduced reaction mechanisms of ozone depletion events in the Arctic spring by using concentration sensitivity analysis and principal component analysis

    Directory of Open Access Journals (Sweden)

    L. Cao

    2016-12-01

    Full Text Available The ozone depletion events (ODEs in the springtime Arctic have been investigated since the 1980s. It is found that the depletion of ozone is highly associated with an auto-catalytic reaction cycle, which involves mostly the bromine-containing compounds. Moreover, bromide stored in various substrates in the Arctic such as the underlying surface covered by ice and snow can be also activated by the absorbed HOBr. Subsequently, this leads to an explosive increase of the bromine amount in the troposphere, which is called the “bromine explosion mechanism”. In the present study, a reaction scheme representing the chemistry of ozone depletion and halogen release is processed with two different mechanism reduction approaches, namely, the concentration sensitivity analysis and the principal component analysis. In the concentration sensitivity analysis, the interdependence of the mixing ratios of ozone and principal bromine species on the rate of each reaction in the ODE mechanism is identified. Furthermore, the most influential reactions in different time periods of ODEs are also revealed. By removing 11 reactions with the maximum absolute values of sensitivities lower than 10 %, a reduced reaction mechanism of ODEs is derived. The onsets of each time period of ODEs in simulations using the original reaction mechanism and the reduced reaction mechanism are identical while the maximum deviation of the mixing ratio of principal bromine species between different mechanisms is found to be less than 1 %. By performing the principal component analysis on an array of the sensitivity matrices, the dependence of a particular species concentration on a combination of the reaction rates in the mechanism is revealed. Redundant reactions are indicated by principal components corresponding to small eigenvalues and insignificant elements in principal components with large eigenvalues. Through this investigation, aside from the 11 reactions identified as

  2. NUCLEAR MAGNETIC RESONANCE THE GELLED PRODUCT OF CANNIZZARO REACTION

    Directory of Open Access Journals (Sweden)

    Lilia Fernández-Sánchez

    2015-03-01

    Full Text Available The paper presents the nuclear magnetic resonance (NMR of proton 1H, carbon 13C and two dimensional spectrums, product of a green organic synthesis of redox on the Cannizzaro reaction. The product was reported as a tribochemical gel (heterogeneous mixture and confirmed by Infrared Spectroscopy IR, X-ray and scanning electron microscope (SEM. The results in this paper confirm its structure through various techniques of NMR and evaluate the content of sodium benzoate and benzyl alcohol in the spectroscopy sample, examining the values of the integrals on 1H NMR signals. The result of analysis indicates that benzyl alcohol (dispersed phase is in 33.44% mol in comparison with sodium benzoate content (continuous phase. These results confirm that the gel structure over time loses the dispersed phase of the benzyl alcohol producing a xerogel.

  3. Multiple-decker phthalocyaninato dinuclear lanthanoid(III) single-molecule magnets with dual-magnetic relaxation processes.

    Science.gov (United States)

    Katoh, Keiichi; Horii, Yoji; Yasuda, Nobuhiro; Wernsdorfer, Wolfgang; Toriumi, Koshiro; Breedlove, Brian K; Yamashita, Masahiro

    2012-11-28

    The SMM behaviour of dinuclear Ln(III)-Pc multiple-decker complexes (Ln = Tb(3+) and Dy(3+)) with energy barriers and slow-relaxation behaviour were explained by using X-ray crystallography and static and dynamic susceptibility measurements. In particular, interactions among the 4f electrons of several dinuclear Ln(III)-Pc type SMMs have never been discussed on the basis of the crystal structure. For dinuclear Tb(III)-Pc complexes, a dual magnetic relaxation process was observed. The relaxation processes are due to the anisotropic centres. Our results clearly show that the two Tb(3+) ion sites are equivalent and are consistent with the crystal structure. On the other hand, the mononuclear Tb(III)-Pc complex exhibited only a single magnetic relaxation process. This is clear evidence that the magnetic relaxation mechanism depends heavily on the dipole-dipole (f-f) interactions between the Tb(3+) ions in the dinuclear systems. Furthermore, the SMM behaviour of dinuclear Dy(III)-Pc type SMMs with smaller energy barriers compared with that of Tb(III)-Pc and slow-relaxation behaviour was explained. Dinuclear Dy(III)-Pc SMMs exhibited single-component magnetic relaxation behaviour. The results indicate that the magnetic relaxation properties of dinuclear Ln(III)-Pc multiple-decker complexes are affected by the local molecular symmetry and are extremely sensitive to tiny distortions in the coordination geometry. In other words, the spatial arrangement of the Ln(3+) ions (f-f interactions) in the crystal is important. Our work shows that the SMM properties can be fine-tuned by introducing weak intermolecular magnetic interactions in a controlled SMM spatial arrangement.

  4. Ultra-high field NMR and MRI - the role of magnet technology to increase sensitivity and specificity

    Science.gov (United States)

    Moser, Ewald; Laistler, Elmar; Schmitt, Franz; Kontaxis, Georg

    2017-08-01

    "History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors." - P. J. Keating (former Australian Prime Minister) Starting with post-war developments in nuclear magnetic resonance (NMR) a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency) were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (NbTi based) superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T) based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T) at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600 - 800 MHz (14.1 - 18.8 T) up to 900 MHz (21 T) at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development towards higher and higher field strength is a consequence of the inherently low and, thus

  5. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Alexander J Taylor

    Full Text Available Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  6. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Science.gov (United States)

    Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M

    2016-01-01

    Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  7. Sensitivity to electronvolt-scale sterile neutrinos at a 3.8-GeV/c muon decay ring

    Energy Technology Data Exchange (ETDEWEB)

    Tunnell, Christopher D. [Univ. of Oxford (United Kingdom)

    2013-03-01

    The liquid-scintillator neutrino-detector (LSND) and mini booster neutrino experiment (MiniBooNE) experiments claim to observe the oscillation $\\bar{v}$μ → $\\bar{v}$e, which can only be explained by additional neutrinos and is a claim that must be further tested. This thesis proposes a new accelerator and experiment called neutrinos from stored muons ( STORM) to refute or confirm the oscillation these claims by studying the CPT-equivalent channel ve → vμ . A 3.8-GeV/c muon decay ring is proposed with neutrino detectors placed 20 m and 2000 m from the decay ring. The detector technology would be a magnetized iron sampling calorimeter, where the magnetic field is induced by a superconducting transmission line. In a frequentist study, the sensitivity of this experiment after 5 years would be >10σ . The range of the thesis discussion starts with the proton front-end design and ends with neutrino parameter estimation. After describing the phenomenology of sterile neutrinos, the facility and detector performance work is presented. Finally, the systematics are explained before the sensitivity and parameter-estimation works are explained

  8. Ultrahigh Sensitive and Flexible Magnetoelectronics with Magnetic Nanocomposites: Toward an Additional Perception of Artificial Intelligence.

    Science.gov (United States)

    Cai, Shu-Yi; Chang, Cheng-Han; Lin, Hung-I; Huang, Yuan-Fu; Lin, Wei-Ju; Lin, Shih-Yao; Liou, Yi-Rou; Shen, Tien-Lin; Huang, Yen-Hsiang; Tsao, Po-Wei; Tzou, Chen-Yang; Liao, Yu-Ming; Chen, Yang-Fang

    2018-05-23

    In recent years, flexible magnetoelectronics has attracted a great attention for its intriguing functionalities and potential applications, such as healthcare, memory, soft robots, navigation, and touchless human-machine interaction systems. Here, we provide the first attempt to demonstrate a new type of magneto-piezoresistance device, which possesses an ultrahigh sensitivity with several orders of resistance change under an external magnetic field (100 mT). In our device, Fe-Ni alloy powders are embedded in the silver nanowire-coated micropyramid polydimethylsiloxane films. Our devices can not only serve as an on/off switch but also act as a sensor that can detect different magnetic fields because of its ultrahigh sensitivity, which is very useful for the application in analog signal communication. Moreover, our devices contain several key features, including large-area and easy fabrication processes, fast response time, low working voltage, low power consumption, excellent flexibility, and admirable compatibility onto a freeform surface, which are the critical criteria for the future development of touchless human-machine interaction systems. On the basis of all of these unique characteristics, we have demonstrated a nontouch piano keyboard, instantaneous magnetic field visualization, and autonomous power system, making our new devices be integrable with magnetic field and enable to be implemented into our daily life applications with unfamiliar human senses. Our approach therefore paves a useful route for the development of wearable electronics and intelligent systems.

  9. Current distribution evaluation of dye-sensitized solar cell using HTS-SQUID-based magnetic measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Kenji, E-mail: Sakai-k@okayama-u.ac.jp; Tanaka, Kohei; Kiwa, Toshihiko; Tsukada, Keiji

    2016-11-15

    Highlights: • Current distribution and direction of dye-sensitized solar cell (DSSC) was measured. • Electrical current flowing in the indium tin oxide (ITO) glass substrate was uniform. • The distribution of electrical current depended on I–V characteristic. • Current direction changed when the performance of DSSC is low. - Abstract: The current flowing inside a dye-sensitized solar cell (DSSC) was measured using a high-temperature superconductor superconducting quantum interference device (HTS-SQUID)-based magnetic measurement system. Further, a new evaluation method of the DSSC, which is difficult to measure using the conventional method, was investigated to improve the characteristics of the DSSC. The tangential components of the magnetic field generated from the DSSC were measured using two HTS-SQUIDs, and the intensity and direction related to the electrical current were obtained by the measured magnetic field. The DSSCs prepared with different dyes and catalytic substances showed different current-intensity mapping. The current direction was different for the DSSC with low performance. In addition, the current flowing in the ITO layer of the ITO glass substrate was also measured and the results confirmed that it had uniform distribution. These results show that the current mapping and the direction of the electrical current depend on the internal factors of the DSSC, and the detection of the magnetic field distribution generated from it is expected to lead to its new evaluation method.

  10. A Novel High Sensitivity Sensor for Remote Field Eddy Current Non-Destructive Testing Based on Orthogonal Magnetic Field

    Directory of Open Access Journals (Sweden)

    Xiaojie Xu

    2014-12-01

    Full Text Available Remote field eddy current is an effective non-destructive testing method for ferromagnetic tubular structures. In view of conventional sensors’ disadvantages such as low signal-to-noise ratio and poor sensitivity to axial cracks, a novel high sensitivity sensor based on orthogonal magnetic field excitation is proposed. Firstly, through a three-dimensional finite element simulation, the remote field effect under orthogonal magnetic field excitation is determined, and an appropriate configuration which can generate an orthogonal magnetic field for a tubular structure is developed. Secondly, optimized selection of key parameters such as frequency, exciting currents and shielding modes is analyzed in detail, and different types of pick-up coils, including a new self-differential mode pick-up coil, are designed and analyzed. Lastly, the proposed sensor is verified experimentally by various types of defects manufactured on a section of a ferromagnetic tube. Experimental results show that the proposed novel sensor can largely improve the sensitivity of defect detection, especially for axial crack whose depth is less than 40% wall thickness, which are very difficult to detect and identify by conventional sensors. Another noteworthy advantage of the proposed sensor is that it has almost equal sensitivity to various types of defects, when a self-differential mode pick-up coil is adopted.

  11. The loss rates of O{sup +} in the inner magnetosphere caused by both magnetic field line curvature scattering and charge exchange reactions

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Y., E-mail: yji@spaceweather.ac.cn [State Key Laboratory of Space Weather, Center for Space Science and Applied Research, Chinese Academy of Sciences, Beijing 100190 (China); College of Earth Science, University of Chinese Academy of Sciences, Beijing 100049 (China); Shen, C. [State Key Laboratory of Space Weather, Center for Space Science and Applied Research, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-03-15

    With consideration of magnetic field line curvature (FLC) pitch angle scattering and charge exchange reactions, the O{sup +} (>300 keV) in the inner magnetosphere loss rates are investigated by using an eigenfunction analysis. The FLC scattering provides a mechanism for the ring current O{sup +} to enter the loss cone and influence the loss rates caused by charge exchange reactions. Assuming that the pitch angle change is small for each scattering event, the diffusion equation including a charge exchange term is constructed and solved; the eigenvalues of the equation are identified. The resultant loss rates of O{sup +} are approximately equal to the linear superposition of the loss rate without considering the charge exchange reactions and the loss rate associated with charge exchange reactions alone. The loss time is consistent with the observations from the early recovery phases of magnetic storms.

  12. Correlation between morphology and magnetic properties of electrochemically produced cobalt powder particles

    Directory of Open Access Journals (Sweden)

    Maksimović Vesna M.

    2015-01-01

    Full Text Available Cobalt 3D powder particles were successfully prepared by the galvanostatic electrodeposition. Electrodeposited cobalt powder were characterized by X-ray diffraction (XRD, scanning electron microscope (SEM, Energy Dispersive Spectroscopy (EDS analysis and SQUID magnetometry. It has been shown that morphology, structure and magnetic properties of cobalt particles are closely associated and can be easily controlled by adjusting process parameters of electrodeposition. Morphology of cobalt powder particles is strongly affected by hydrogen evolution reaction as a parallel reaction to cobalt electrodeposition. Depending on the applied current density, the two types of powder particles were formed: dendrites at lower and spongy-like particles at higher current densities. Morphologies and structures of powder particles are correlated with their magnetic properties, and compared with those of the bulk cobalt. In comparison with the properties of bulk cobalt, the obtained 3D structures exhibited a decreased saturation magnetization (MS, but an enhanced coercivity (HC which is explained by their peculiar morphology. [Projekat Ministarstva nauke Republike Srbije, br. III 45012

  13. The OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) is reliable and sensitive to change: results from an OMERACT workshop

    DEFF Research Database (Denmark)

    Bøyesen, Pernille; McQueen, Fiona M; Gandjbakhch, Frédérique

    2011-01-01

    The aim of this multireader exercise was to assess the reliability and sensitivity to change of the psoriatic arthritis magnetic resonance imaging score (PsAMRIS) in PsA patients followed for 1 year.......The aim of this multireader exercise was to assess the reliability and sensitivity to change of the psoriatic arthritis magnetic resonance imaging score (PsAMRIS) in PsA patients followed for 1 year....

  14. Thermo-sensitively and magnetically ordered mesoporous carbon nanospheres for targeted controlled drug release and hyperthermia application.

    Science.gov (United States)

    Chen, Lin; Zhang, Huan; Zheng, Jing; Yu, Shiping; Du, Jinglei; Yang, Yongzhen; Liu, Xuguang

    2018-03-01

    A multifunctional nanoplatform based on thermo-sensitively and magnetically ordered mesoporous carbon nanospheres (TMOMCNs) is developed for effective targeted controlled release of doxorubicin hydrochloride (DOX) and hyperthermia in this work. The morphology, specific surface area, porosity, thermo-stability, thermo-sensitivity, as well as magnetism properties of TMOMCNs were verified by high resolution transmission electron microscopy, field emission scanning electron microscopy, thermo-gravimetric analysis, X-ray diffraction, Brunauer-Emmeltt-Teller surface area analysis, dynamic light scattering and vibrating sample magnetometry measurement. The results indicate that TMOMCNs have an average diameter of ~146nm with a lower critical solution temperature at around 39.5°C. They are superparamagnetic with a magnetization of 10.15emu/g at 20kOe. They generate heat when inductive magnetic field is applied to them and have a normalized specific absorption rate of 30.23W/g at 230kHz and 290Oe, showing good potential for hyperthermia. The DOX loading and release results illustrate that the loading capacity is 135.10mg/g and release performance could be regulated by changing pH and temperature. The good targeting, DOX loading and release and hyperthermia properties of TMOMCNs offer new probabilities for high effectiveness and low toxicity of cancer chemotherapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Application of magnetic nanoparticle MnFe_2O_4 type as a catalyst in esterification reaction

    International Nuclear Information System (INIS)

    Pereira, K.R. de O.; Barros, A.B. de S.; Moura, T.F.B. de; Vilar, E.; Dantas, J.; Costa, A. C. F. de M.

    2016-01-01

    The interest in obtaining renewable energy arouses the interest of researchers in the development of biofuels to replace conventional fuels. This work aimed to obtain magnetic nanoparticle MnFe_2O_4 and evaluate their performance as a catalyst in esterification reaction to obtain biodiesel. The sample was synthesized through the combustion reaction and characterized by XRD, SEM and BET. The esterification reaction, the methyl ethyl route was conducted in a high pressure reactor at 180 ° C for 1 hour with oil molar ratio 1:12 alcohol with 2% catalyst. The results indicate the formation of the phase MnFe_2O_4 and agglomerate in the form of irregular plate, with particles bound strongly to the surface of the agglomerates. The catalytic tests showed that sample was active for the reaction of esterification methyl ethyl route, with conversions of 52% and 48%, respectively. (author)

  16. Charged-particle magnetic-quadrupole spectrometer for neutron induced reactions

    International Nuclear Information System (INIS)

    Haight, R.C.; Grimes, S.M.; Tuckey, B.J.; Anderson, J.D.

    1975-01-01

    A spectrometer has been developed for measuring the charged particle production cross sections and spectra in neutron-induced reactions. The spectrometer consists of a magnetic quadrupole doublet which focuses the charged particles onto a silicon surface barrier detector telescope which is 2 meters or more from the irradiated sample. Collimators, shielding, and the large source-to-detector distance reduce the background enough to use the spectrometer with a 14-MeV neutron source producing 4 . 10 12 n/s. The spectrometer has been used in investigations of proton, deuteron, and alpha particle production by 14-MeV neutrons incident on various materials. Protons with energies as low as 1.1 MeV have been measured. The good resolution of the detectors has also made possible an improved measurement of the neutron- neutron scattering length from the 0 0 proton spectrum from deuteron breakup by 14-MeV neutrons

  17. A new approach for crystallization of copper(ii) oxide hollow nanostructures with superior catalytic and magnetic response

    Science.gov (United States)

    Singh, Inderjeet; Landfester, Katharina; Chandra, Amreesh; Muñoz-Espí, Rafael

    2015-11-01

    We report the synthesis of copper(ii) oxide hollow nanostructures at ambient pressure and close to room temperature by applying the soft templating effect provided by the confinement of droplets in miniemulsion systems. Particle growth can be explained by considering a mechanism that involves both diffusion and reaction control. The catalytic reduction of p-nitrophenol in aqueous media is used as a model reaction to prove the catalytic activity of the materials: the synthesized hollow structures show nearly 100 times higher rate constants than solid CuO microspheres. The kinetic behavior and the order of the reduction reaction change due to the increase of the surface area of the hollow structures. The synthesis also leads to modification of physical properties such as magnetism.We report the synthesis of copper(ii) oxide hollow nanostructures at ambient pressure and close to room temperature by applying the soft templating effect provided by the confinement of droplets in miniemulsion systems. Particle growth can be explained by considering a mechanism that involves both diffusion and reaction control. The catalytic reduction of p-nitrophenol in aqueous media is used as a model reaction to prove the catalytic activity of the materials: the synthesized hollow structures show nearly 100 times higher rate constants than solid CuO microspheres. The kinetic behavior and the order of the reduction reaction change due to the increase of the surface area of the hollow structures. The synthesis also leads to modification of physical properties such as magnetism. Electronic supplementary information (ESI) available: Associated structural and morphological analysis, XPS characterization, BET surface area, catalytic measurements, recycle tests of the catalyst, and magnetic characterizations. See DOI: 10.1039/c5nr05579b

  18. Design of a sensitive aptasensor based on magnetic microbeads-assisted strand displacement amplification and target recycling.

    Science.gov (United States)

    Li, Ying; Ji, Xiaoting; Song, Weiling; Guo, Yingshu

    2013-04-03

    A cross-circular amplification system for sensitive detection of adenosine triphosphate (ATP) in cancer cells was developed based on aptamer-target interaction, magnetic microbeads (MBs)-assisted strand displacement amplification and target recycling. Here we described a new recognition probe possessing two parts, the ATP aptamer and the extension part. The recognition probe was firstly immobilized on the surface of MBs and hybridized with its complementary sequence to form a duplex. When combined with ATP, the probe changed its conformation, revealing the extension part in single-strand form, which further served as a toehold for subsequent target recycling. The released complementary sequence of the probe acted as the catalyst of the MB-assisted strand displacement reaction. Incorporated with target recycling, a large amount of biotin-tagged MB complexes were formed to stimulate the generation of chemiluminescence (CL) signal in the presence of luminol and H2O2 by incorporating with streptavidin-HRP, reaching a detection limit of ATP as low as 6.1×10(-10)M. Moreover, sample assays of ATP in Ramos Burkitt's lymphoma B cells were performed, which confirmed the reliability and practicality of the protocol. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Magnetic particles as powerful purification tool for high sensitive mass spectrometric screening procedures.

    Science.gov (United States)

    Peter, Jochen F; Otto, Angela M

    2010-02-01

    The effective isolation and purification of proteins from biological fluids is the most crucial step for a successful protein analysis when only minute amounts are available. While conventional purification methods such as dialysis, ultrafiltration or protein precipitation often lead to a marked loss of protein, SPE with small-sized particles is a powerful alternative. The implementation of particles with superparamagnetic cores facilitates the handling of those particles and allows the application of particles in the nanometer to low micrometer range. Due to the small diameters, magnetic particles are advantageous for increasing sensitivity when using subsequent MS analysis or gel electrophoresis. In the last years, different types of magnetic particles were developed for specific protein purification purposes followed by analysis or screening procedures using MS or SDS gel electrophoresis. In this review, the use of magnetic particles for different applications, such as, the extraction and analysis of DNA/RNA, peptides and proteins, is described.

  20. Electron spin resonance as a high sensitivity technique for environmental magnetism: determination of contamination in carbonate sediments

    Science.gov (United States)

    Crook, Nigel P.; Hoon, Stephen R.; Taylor, Kevin G.; Perry, Chris T.

    2002-05-01

    This study investigates the application of high sensitivity electron spin resonance (ESR) to environmental magnetism in conjunction with the more conventional techniques of magnetic susceptibility, vibrating sample magnetometry (VSM) and chemical compositional analysis. Using these techniques we have studied carbonate sediment samples from Discovery Bay, Jamaica, which has been impacted to varying degrees by a bauxite loading facility. The carbonate sediment samples contain magnetic minerals ranging from moderate to low concentrations. The ESR spectra for all sites essentially contain three components. First, a six-line spectra centred around g = 2 resulting from Mn2+ ions within a carbonate matrix; second a g = 4.3 signal from isolated Fe3+ ions incorporated as impurities within minerals such as gibbsite, kaolinite or quartz; third a ferrimagnetic resonance with a maxima at 230 mT resulting from the ferrimagnetic minerals present within the bauxite contamination. Depending upon the location of the sites within the embayment these signals vary in their relative amplitude in a systematic manner related to the degree of bauxite input. Analysis of the ESR spectral components reveals linear relationships between the amplitude of the Mn2+ and ferrimagnetic signals and total Mn and Fe concentrations. To assist in determining the origin of the ESR signals coral and bauxite reference samples were employed. Coral representative of the matrix of the sediment was taken remote from the bauxite loading facility whilst pure bauxite was collected from nearby mining facilities. We find ESR to be a very sensitive technique particularly appropriate to magnetic analysis of ferri- and para-magnetic components within environmental samples otherwise dominated by diamagnetic (carbonate) minerals. When employing typical sample masses of 200 mg the practical detection limit of ESR to ferri- and para-magnetic minerals within a diamagnetic carbonate matrix is of the order of 1 ppm and 1 ppb

  1. Design and synthesis study of the thermo-sensitive poly (N-vinylpyrrolidone-b- N, N-diethylacrylamide).

    Science.gov (United States)

    Zhang, Xiayun; Yang, Zhongduo; Xie, Dengmin; Liu, Donglei; Chen, Zhenbin; Li, Ke; Li, Zhizhong; Tichnell, Brandon; Liu, Zhen

    2018-01-01

    The reversible addition fragmentation chain transfer (RAFT) polymerization method was adopted here to prepare a series of thermo-sensitive copolymers, poly (N,N-diethyl- acrylamide-b-N-vinylpyrrolidone). Their structures, molecular weight distribution and temperature sensitivity performances were characterized by the nuclear magnetic resonance ( 1 HNMR), the gel permeation chromatography (GPC) and the fluorescence spectrophotometer, respectively. It has been identified that the synthesis reaction of the block copolymer was living polymerization. The thermo-sensitivity study suggested that N-vinylpyrrolidone (NVP), played a key role on the lower critical solution temperature (LCST) performance.

  2. The wireless internet explained

    CERN Document Server

    Rhoton, John

    2001-01-01

    The Wireless Internet Explained covers the full spectrum of wireless technologies from a wide range of vendors, including initiatives by Microsoft and Compaq. The Wireless Internet Explained takes a practical look at wireless technology. Rhoton explains the concepts behind the physics, and provides an overview that clarifies the convoluted set of standards heaped together under the umbrella of wireless. It then expands on these technical foundations to give a panorama of the increasingly crowded landscape of wireless product offerings. When it comes to actual implementation the book gives abundant down-to-earth advice on topics ranging from the selection and deployment of mobile devices to the extremely sensitive subject of security.Written by an expert on Internet messaging, the author of Digital Press''s successful Programmer''s Guide to Internet Mail and X.400 and SMTP: Battle of the E-mail Protocols, The Wireless Internet Explained describes and evaluates the current state of the fast-growing and crucial...

  3. A disposable electrochemical immunosensor for prolactin involving affinity reaction on streptavidin-functionalized magnetic particles

    International Nuclear Information System (INIS)

    Moreno-Guzman, Maria; Gonzalez-Cortes, Araceli; Yanez-Sedeno, Paloma; Pingarron, Jose M.

    2011-01-01

    A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL -1 with a slope value of 7.0 nA mL ng -1 . The limit of detection was 3.74 ng mL -1 . Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.

  4. A disposable electrochemical immunosensor for prolactin involving affinity reaction on streptavidin-functionalized magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Guzman, Maria; Gonzalez-Cortes, Araceli [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain); Yanez-Sedeno, Paloma, E-mail: yseo@quim.ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain); Pingarron, Jose M. [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain)

    2011-04-29

    A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL{sup -1} with a slope value of 7.0 nA mL ng{sup -1}. The limit of detection was 3.74 ng mL{sup -1}. Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.

  5. A hyperpolarized equilibrium for magnetic resonance.

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B; Mewis, Ryan E; Highton, Louise A R; Kenny, Stephen M; Green, Gary G R; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  6. Toehold-mediated strand displacement reaction-dependent fluorescent strategy for sensitive detection of uracil-DNA glycosylase activity.

    Science.gov (United States)

    Wu, Yushu; Wang, Lei; Jiang, Wei

    2017-03-15

    Sensitive detection of uracil-DNA glycosylase (UDG) activity is beneficial for evaluating the repairing process of DNA lesions. Here, toehold-mediated strand displacement reaction (TSDR)-dependent fluorescent strategy was constructed for sensitive detection of UDG activity. A single-stranded DNA (ssDNA) probe with two uracil bases and a trigger sequence were designed. A hairpin probe with toehold domain was designed, and a reporter probe was also designed. Under the action of UDG, two uracil bases were removed from ssDNA probe, generating apurinic/apyrimidinic (AP) sites. Then, the AP sites could inhibit the TSDR between ssDNA probe and hairpin probe, leaving the trigger sequence in ssDNA probe still free. Subsequently, the trigger sequence was annealed with the reporter probe, initiating the polymerization and nicking amplification reaction. As a result, numerous G-quadruplex (G4) structures were formed, which could bind with N-methyl-mesoporphyrin IX (NMM) to generate enhanced fluorescent signal. In the absence of UDG, the ssDNA probe could hybridize with the toehold domain of the hairpin probe to initiate TSDR, blocking the trigger sequence, and then the subsequent amplification reaction would not occur. The proposed strategy was successfully implemented for detecting UDG activity with a detection limit of 2.7×10 -5 U/mL. Moreover, the strategy could distinguish UDG well from other interference enzymes. Furthermore, the strategy was also applied for detecting UDG activity in HeLa cells lysate with low effect of cellular components. These results indicated that the proposed strategy offered a promising tool for sensitive quantification of UDG activity in UDG-related function study and disease prognosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Phosphorus-31 NMR magnetization transfer measurements of metabolic reaction rates in the rat heart and kidney in vivo

    International Nuclear Information System (INIS)

    Koretsky, A.P.

    1984-01-01

    31 P NMR is a unique tool to study bioenergetics in living cells. The application of magnetization transfer techniques to the measurement of steady-state enzyme reaction rates provides a new approach to understanding the regulation of high energy phosphate metabolism. This dissertation is concerned with the measurement of the rates of ATP synthesis in the rat kidney and of the creatine kinase catalyzed reaction in the rat heart in situ. The theoretical considerations of applying magnetization transfer techniques to intact organs are discussed with emphasis on the problems associated with multiple exchange reactions and compartmentation of reactants. Experimental measurements of the ATP synthesis rate were compared to whole kidney oxygen consumption and Na + reabsorption rates to derive ATP/O values. The problems associated with ATP synthesis rate measurements in kidney, e.g. the heterogeneity of the inorganic phosphate resonance, are discussed and experiments to overcome these problems proposed. In heart, the forward rate through creatine kinase was measured to be larger than the reverse rate. To account for the difference in forward and reverse rates a model is proposed based on the compartmentation of a small pool of ATP

  8. Two-dimensional sensitivity calculation code: SENSETWO

    International Nuclear Information System (INIS)

    Yamauchi, Michinori; Nakayama, Mitsuo; Minami, Kazuyoshi; Seki, Yasushi; Iida, Hiromasa.

    1979-05-01

    A SENSETWO code for the calculation of cross section sensitivities with a two-dimensional model has been developed, on the basis of first order perturbation theory. It uses forward neutron and/or gamma-ray fluxes and adjoint fluxes obtained by two-dimensional discrete ordinates code TWOTRAN-II. The data and informations of cross sections, geometry, nuclide density, response functions, etc. are transmitted to SENSETWO by the dump magnetic tape made in TWOTRAN calculations. The required input for SENSETWO calculations is thus very simple. The SENSETWO yields as printed output the cross section sensitivities for each coarse mesh zone and for each energy group, as well as the plotted output of sensitivity profiles specified by the input. A special feature of the code is that it also calculates the reaction rate with the response function used as the adjoint source in TWOTRAN adjoint calculation and the calculated forward flux from the TWOTRAN forward calculation. (author)

  9. Laser flash photolysis and magnetic-field-effect studies on interaction of thymine and thymidine with menadione: role of sugar in controlling reaction pattern

    Directory of Open Access Journals (Sweden)

    Adity Bose, Debarati Dey and Samita Basu

    2008-01-01

    Full Text Available The magnetic field effect (MFE in conjunction with laser flash photolysis has been used for the study of the interaction of one of the small drug like quinone molecules, 2-methyl, 1,4-naphthoquinone, commonly known as menadione (MQ, with one of the DNA bases, thymine (THN, and its corresponding nucleoside, thymidine (THDN, in acetonitrile (ACN and sodium dodecylsulfate (SDS micelles. It has been observed that THN undergoes electron transfer (ET and hydrogen (H abstraction with MQ, while THDN undergoes only H abstraction in both the media. However, our earlier studies showed that a purine base, adenine (ADN, and its nucleoside, 2'-deoxyadenosine (ADS, undergo ET in ACN and H abstraction in SDS. Here we have attempted to explain the differences in the reactions of these DNA bases with MQ. We also reveal the crucial role of a sugar unit in altering the behavior of purine and pyrimidine bases with respect to ET and H abstraction.

  10. Laser flash photolysis and magnetic-field-effect studies on interaction of thymine and thymidine with menadione: role of sugar in controlling reaction pattern

    Science.gov (United States)

    Bose, Adity; Dey, Debarati; Basu, Samita

    2008-04-01

    The magnetic field effect (MFE) in conjunction with laser flash photolysis has been used for the study of the interaction of one of the small drug like quinone molecules, 2-methyl, 1,4-naphthoquinone, commonly known as menadione (MQ), with one of the DNA bases, thymine (THN), and its corresponding nucleoside, thymidine (THDN), in acetonitrile (ACN) and sodium dodecylsulfate (SDS) micelles. It has been observed that THN undergoes electron transfer (ET) and hydrogen (H) abstraction with MQ, while THDN undergoes only H abstraction in both the media. However, our earlier studies showed that a purine base, adenine (ADN), and its nucleoside, 2'-deoxyadenosine (ADS), undergo ET in ACN and H abstraction in SDS. Here we have attempted to explain the differences in the reactions of these DNA bases with MQ. We also reveal the crucial role of a sugar unit in altering the behavior of purine and pyrimidine bases with respect to ET and H abstraction.

  11. Laser flash photolysis and magnetic-field-effect studies on interaction of thymine and thymidine with menadione: role of sugar in controlling reaction pattern

    International Nuclear Information System (INIS)

    Bose, Adity; Dey, Debarati; Basu, Samita

    2008-01-01

    The magnetic field effect (MFE) in conjunction with laser flash photolysis has been used for the study of the interaction of one of the small drug like quinone molecules, 2-methyl, 1,4-naphthoquinone, commonly known as menadione (MQ), with one of the DNA bases, thymine (THN), and its corresponding nucleoside, thymidine (THDN), in acetonitrile (ACN) and sodium dodecylsulfate (SDS) micelles. It has been observed that THN undergoes electron transfer (ET) and hydrogen (H) abstraction with MQ, while THDN undergoes only H abstraction in both the media. However, our earlier studies showed that a purine base, adenine (ADN), and its nucleoside, 2'-deoxyadenosine (ADS), undergo ET in ACN and H abstraction in SDS. Here we have attempted to explain the differences in the reactions of these DNA bases with MQ. We also reveal the crucial role of a sugar unit in altering the behavior of purine and pyrimidine bases with respect to ET and H abstraction

  12. Laser flash photolysis and magnetic-field-effect studies on interaction of thymine and thymidine with menadione: role of sugar in controlling reaction pattern

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Adity; Dey, Debarati; Basu, Samita [Chemical Sciences Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata-700 064 (India)], E-mail: samita.basu@saha.ac.in

    2008-04-01

    The magnetic field effect (MFE) in conjunction with laser flash photolysis has been used for the study of the interaction of one of the small drug like quinone molecules, 2-methyl, 1,4-naphthoquinone, commonly known as menadione (MQ), with one of the DNA bases, thymine (THN), and its corresponding nucleoside, thymidine (THDN), in acetonitrile (ACN) and sodium dodecylsulfate (SDS) micelles. It has been observed that THN undergoes electron transfer (ET) and hydrogen (H) abstraction with MQ, while THDN undergoes only H abstraction in both the media. However, our earlier studies showed that a purine base, adenine (ADN), and its nucleoside, 2'-deoxyadenosine (ADS), undergo ET in ACN and H abstraction in SDS. Here we have attempted to explain the differences in the reactions of these DNA bases with MQ. We also reveal the crucial role of a sugar unit in altering the behavior of purine and pyrimidine bases with respect to ET and H abstraction.

  13. A biodegradable shape-memory nanocomposite with excellent magnetism sensitivity

    International Nuclear Information System (INIS)

    Yu Xiongjun; Zhou Shaobing; Zheng Xiaotong; Guo Tao; Xiao Yu; Song Botao

    2009-01-01

    This paper reports a kind of biodegradable nanocomposite which can show an excellent shape-memory property in hot water or in an alternating magnetic field with f = 20 kH and H = 6.8 kA m -1 . The nanocomposite is composed of crosslinked poly(ε-caprolactone) (c-PCL) and Fe 3 O 4 nanoparticles. The crosslinking reaction in PCL with linear molecular structure was realized using benzoyl peroxide (BPO) as an initiator. The biocompatible Fe 3 O 4 magnetite nanoparticles with an average size of 10 nm were synthesized according to a chemical coprecipitation method. The initial results from c-PCL showed crosslinking modification had brought about a large enhancement in shape-memory effect for PCL. Then a series of composites made of Fe 3 O 4 nanoparticles and c-PCL were prepared and their morphological properties, mechanical properties, thermodynamic properties and shape-memory effect were investigated in succession. Significantly, the photos of the shape-memory process confirmed the anticipatory magnetically responsive shape-recovery effect of the nanocomposites because inductive heat from Fe 3 O 4 can be utilized to actuate the c-PCL vivification from their frozen temporary shape. All the results imply a very feasible method to fabricate shape-memory PCL-based nanocomposites since just a simple modification is required. Additionally, this modification would endow an excellent shape-memory effect to all other kinds of polymers so that they could broadly serve in various fields, especially in medicine.

  14. Transcranial magnetic stimulation (TMS): compared sensitivity of different motor response parameters in ALS.

    Science.gov (United States)

    Pouget, J; Trefouret, S; Attarian, S

    2000-06-01

    Owing to the low sensitivity of clinical signs in assessing upper motor neuron (UMN) involvement in ALS, there is a need for investigative tools capable of detecting abnormal function of the pyramidal tract. Transcranial magnetic stimulation (TMS) may contribute to the diagnosis by reflecting a UMN dysfunction that is not clinically detectable. Several parameters for the motor responses to TMS can be evaluated with different levels of significance in healthy subjects compared with ALS patients. The central motor conduction time, however, is not sensitive in detecting subclinical UMN defects in individual ALS patients. The amplitude of the motor evoked potential (MEP), expressed as the percentage of the maximum wave, also has a low sensitivity. In some cases, the corticomotor threshold is decreased early in the disease course as a result of corticomotor neuron hyperexcitability induced by glutamate. Later, the threshold increases, indicating a loss of UMN. In our experience, a decreased silent period duration appears to be the most sensitive parameter when using motor TMS in ALS. TMS is also a sensitive technique for investigating the corticobulbar tract, which is difficult to study by other methods. TMS is a widely available, painless and safe technique with a good sensitivity that can visualize both corticospinal and corticobulbar tract abnormalities. The sensitivity can be improved further by taking into account the several MEP parameters, including latency and cortical silent period decreased duration.

  15. Simultaneous detection of Acidovorax avenae subsp. citrulli and Didymella bryoniae in cucurbit seedlots using magnetic capture hybridization and real-time polymerase chain reaction.

    Science.gov (United States)

    Ha, Y; Fessehaie, A; Ling, K S; Wechter, W P; Keinath, A P; Walcott, R R

    2009-06-01

    To improve the simultaneous detection of two pathogens in cucurbit seed, a combination of magnetic capture hybridization (MCH) and multiplex real-time polymerase chain reaction (PCR) was developed. Single-stranded DNA hybridization capture probes targeting DNA of Acidovorax avenae subsp. citrulli, causal agent of bacterial fruit blotch, and Didymella bryoniae, causal agent of gummy stem blight, were covalently attached to magnetic particles and used to selectively concentrate template DNA from cucurbit seed samples. Sequestered template DNAs were subsequently amplified by multiplex real-time PCR using pathogen-specific TaqMan PCR assays. The MCH multiplex real-time PCR assay displayed a detection threshold of A. avenae subsp. citrulli at 10 CFU/ml and D. bryoniae at 10(5) conidia/ml in mixtures of pure cultures of the two pathogens, which was 10-fold more sensitive than the direct real-time PCR assays for the two pathogens separately. Although the direct real-time PCR assay displayed a detection threshold for A. avenae subsp. citrulli DNA of 100 fg/microl in 25% (1/4 samples) of the samples assayed, MCH real-time PCR demonstrated 100% detection frequency (4/4 samples) at the same DNA concentration. MCH did not improve detection sensitivity for D. bryoniae relative to direct real-time PCR using conidial suspensions or seed washes from D. bryoniae-infested cucurbit seed. However, MCH real-time PCR facilitated detection of both target pathogens in watermelon and melon seed samples (n = 5,000 seeds/sample) in which 0.02% of the seed were infested with A. avenae subsp. citrulli and 0.02% were infested with D. bryoniae.

  16. Probing stochastic inter-galactic magnetic fields using blazar-induced gamma ray halo morphology

    Energy Technology Data Exchange (ETDEWEB)

    Duplessis, Francis [Physics Department, Arizona State University, Tempe, AZ 85287 (United States); Vachaspati, Tanmay, E-mail: fdupless@asu.edu, E-mail: tvachasp@asu.edu [Maryland Center for Fundamental Physics, University of Maryland, College Park, MD 20742 (United States)

    2017-05-01

    Inter-galactic magnetic fields can imprint their structure on the morphology of blazar-induced gamma ray halos. We show that the halo morphology arises through the interplay of the source's jet and a two-dimensional surface dictated by the magnetic field. Through extensive numerical simulations, we generate mock halos created by stochastic magnetic fields with and without helicity, and study the dependence of the halo features on the properties of the magnetic field. We propose a sharper version of the Q-statistics and demonstrate its sensitivity to the magnetic field strength, the coherence scale, and the handedness of the helicity. We also identify and explain a new feature of the Q-statistics that can further enhance its power.

  17. Increasing the sensitivity for stem cell monitoring in system-function based magnetic particle imaging

    International Nuclear Information System (INIS)

    Them, Kolja; Szwargulski, P; Knopp, Tobias; Salamon, J; Kaul, M G; Ittrich, H; Sequeira, S; Lange, C

    2016-01-01

    The use of superparamagnetic iron oxide nanoparticles (SPIONs) has provided new possibilities in biophysics and biomedical imaging technologies. The magnetization dynamics of SPIONs, which can be influenced by the environment, are of central interest. In this work, different biological SPION environments are used to investigate three different calibration methods for stem cell monitoring in magnetic particle imaging. It is shown that calibrating using SPIONs immobilized via agarose gel or intracellular uptake results in superior stem cell image quality compared to mobile SPIONs in saline. This superior image quality enables more sensitive localization and identification of a significantly smaller number of magnetically labeled stem cells. The results are important for cell tracking and monitoring of future SPION based therapies such as hyperthermia based cancer therapies, targeted drug delivery, or tissue regeneration approaches where it is crucial to image a sufficiently small number of SPIONs interacting with biological matter. (paper)

  18. A sensitive colorimetric aptasensor based on trivalent peroxidase-mimic DNAzyme and magnetic nanoparticles.

    Science.gov (United States)

    Liu, Shuwen; Xu, Naihan; Tan, Chunyan; Fang, Wei; Tan, Ying; Jiang, Yuyang

    2018-08-14

    In this study, a novel colorimetric aptasensor was prepared by coupling trivalent peroxidase-mimic DNAzyme and magnetic nanoparticles for highly sensitive and selective detection of target proteins. A three G-quadruplex (G4) DNA-hemin complex was employed as the trivalent peroxidase-mimic DNAzyme, in which hemin assisted the G4-DNA to fold into a catalytic conformation and act as an enzyme. The design of the aptasensor includes magnetic nanoparticles (MNPs), complementary DNA (cDNA) modified with biotin, and a label-free single strand DNA (ssDNA) including the aptamer and trivalent peroxidase-mimic DNAzyme. The trivalent DNAzyme, which has the highest catalytic activity among multivalent DNAzymes, catalyzed the H 2 O 2 -mediated oxidation of ABTS. The colorless ABTS was oxidized to produce a blue-green product that can be clearly distinguished by the naked eye. The aptamer and trivalent peroxidase-mimic DNAzyme promote the specificity and sensitivity of this detection method, which can be generalized for other targets by simply replacing the corresponding aptamers. To demonstrate the feasible use of the aptasensor for target detection, a well-known tumor biomarker MUC1 was evaluated as the model target. The limits of detection were determined to be 5.08 and 5.60 nM in a linear range of 50-1000 nM in a buffer solution and 10% serum system, respectively. This colorimetric and label-free aptasensor with excellent sensitivity and strong anti-interference ability has potential application in disease diagnoses, prognosis tracking, and therapeutic evaluation. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Iron-platinum multilayer thin film reactions to form L1(0) iron-platinum and exchange spring magnets

    Science.gov (United States)

    Yao, Bo

    FePt films with the L10 phase have potential applications for magnetic recording and permanent magnets due to its high magnetocrystalline anisotropy energy density. Heat treatment of [Fe/Pt] n multilayer films is one approach to form the L10 FePt phase through a solid state reaction. This thesis has studied the diffusion and reaction of [Fe/Pt]n multilayer films to form the L10 FePt phase and has used this understanding to construct exchange spring magnets. The process-structure-property relations of [Fe/Pt] n multilayer films were systematically examined. The transmission electron microscopy (TEM) study of the annealed multilayers indicates that the Pt layer grows at the expense of Fe during annealing, forming a disordered fcc FePt phase by the interdiffusion of Fe into Pt. This thickening of the fcc Pt layer can be attributed to the higher solubilities of Fe into fcc Pt, as compared to the converse. For the range of film thickness studied, a continuous L10 FePt product layer that then thickens with further annealing is not found. Instead, the initial L10 FePt grains are distributed mainly on the grain boundaries within the fcc FePt layer and at the Fe/Pt interfaces and further transformation of the sample to the ordered L10 FePt phase proceeds coupled with the growth of the initial L10 FePt grains. A comprehensive study of annealed [Fe/Pt]n films is provided concerning the phase fraction, grain size, nucleation/grain density, interdiffusivity, long-range order parameter, and texture, as well as magnetic properties. A method based on hollow cone dark field TEM is introduced to measure the volume fraction, grain size, and density of ordered L10 FePt phase grains in the annealed films, and low-angle X-ray diffraction is used to measure the effective Fe-Pt interdiffusivity. The process-structure-properties relations of two groups of samples with varying substrate temperature and periodicity are reported. The results demonstrate that the processing parameters

  20. Dynamic rheological properties of viscoelastic magnetic fluids in uniform magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Niu Xiaodong; Ye Xiaojiang; Li Mingjun; Iwamoto, Yuhiro

    2012-01-01

    The dynamic rheological properties of viscoelastic magnetic fluids in externally applied uniform magnetic fields are investigated by a laboratory-made cone-plate rheometer in this study. In particular, the effects of the magnetic field on the viscoelastic properties (the complex dynamic modulus) of the viscoelastic magnetic fluids are studied. In the investigation, three viscoelastic magnetic fluids are made by mixing a magnetic fluid and a viscoelastic fluid with different mass ratios. As a supplementation to the experimental investigation, a theoretical analysis is also presented. The present study shows that the viscosity and elasticity of the viscoelastic magnetic fluids are significantly influenced by the magnetic field and the concentrations of the magnetic particles in the test fluids. Theoretical analysis qualitatively explains the present findings. - Highlights: ► The dynamic rheological properties of the viscoelastic magnetic fluids in uniform magnetic fields are investigated. ► Both the magnetic field strength and the concentration of the magnetic particles in the fluids have significant effects on the viscosity and elasticity of the viscoelastic magnetic fluids. ► Theoretical prediction and analysis qualitatively explains the present findings.

  1. Synthesis and characterization of NiFe{sub 2}O{sub 4}–Pd magnetically recyclable catalyst for hydrogenation reaction

    Energy Technology Data Exchange (ETDEWEB)

    Karaoğlu, E., E-mail: ekaraoglu@fatih.edu.tr [Department of Chemistry, Faculty of Arts and Sciences, Fatih University, 34500 B. Cekmece, Istanbul (Turkey); Özel, U.; Caner, C.; Baykal, A.; Summak, M.M. [Department of Chemistry, Faculty of Arts and Sciences, Fatih University, 34500 B. Cekmece, Istanbul (Turkey); Sözeri, H. [TUBITAK-UME, National Metrology Institute, PO Box 54, 41470 Gebze-Kocaeli (Turkey)

    2012-12-15

    Graphical abstract: Display Omitted Highlights: ► Novel superparamagnetic NiFe{sub 2}O{sub 4}–Pd magnetically recyclable catalyst was fabricated through co-precipitation. ► It could be reused several times without significant loss in catalytic activity for hydrogenation reaction. ► No further modification of the NiFe{sub 2}O{sub 4}–Pd magnetically recyclable catalyst is necessary for utilization as catalyst. -- Abstract: Herein we report the fabrication and characterization magnetically recyclable catalysts of NiFe{sub 2}O{sub 4}–Pd nanocomposite as highly effective catalysts for reduction reactions in liquid phase. The reduction Pd{sup 2+} was accomplished with polyethylene glycol 400 (PEG-400) instead of sodium borohydride (NaBH{sub 4}) and NiFe{sub 2}O{sub 4} nanoparticles was prepared by sonochemically using FeCI{sub 3}·6H{sub 2}O and NiCl{sub 2}. The chemical characterization of the product was done with X-ray diffractometry, Infrared spectroscopy, transmission electron microscopy, UV–Vis spectroscopy, thermal gravimetry and inductively coupled plasma. Thus formed NiFe{sub 2}O{sub 4}–Pd MRCs showed a very high activity in reduction reactions of 4-nitro aniline and 1,3-dinitrobenzene in liquid phase. It was found out that the catalytic activity of NiFe{sub 2}O{sub 4}–Pd MRCs on the reduction of 4-nitro aniline and 1,3-dinitrobenzene in liquid phase are between 99–93% and 98–93%, respectively. Magnetic character of this system allowed recovery and multiple use without significant loss of its catalytic activity. It is found that NiFe{sub 2}O{sub 4}–Pd MRCs showed very efficient catalytic activity and multiple usability.

  2. Prototype of haptic device for sole of foot using magnetic field sensitive elastomer

    Science.gov (United States)

    Kikuchi, T.; Masuda, Y.; Sugiyama, M.; Mitsumata, T.; Ohori, S.

    2013-02-01

    Walking is one of the most popular activities and a healthy aerobic exercise for the elderly. However, if they have physical and / or cognitive disabilities, sometimes it is challenging to go somewhere they don't know well. The final goal of this study is to develop a virtual reality walking system that allows users to walk in virtual worlds fabricated with computer graphics. We focus on a haptic device that can perform various plantar pressures on users' soles of feet as an additional sense in the virtual reality walking. In this study, we discuss a use of a magnetic field sensitive elastomer (MSE) as a working material for the haptic interface on the sole. The first prototype with MSE was developed and evaluated in this work. According to the measurement of planter pressures, it was found that this device can perform different pressures on the sole of a light-weight user by applying magnetic field on the MSE. The result also implied necessities of the improvement of the magnetic circuit and the basic structure of the mechanism of the device.

  3. Magnetic and optical effects in TiO2 based dye sensitized solar cells

    Science.gov (United States)

    Kannan U., M.; Jammalamadaka, S. Narayana

    2018-04-01

    We report on the magnetic effects on the solar cell efficiency of TiO2 based dye sensitized solar cells (DSSC). The strong spin orbit coupling of rare earth Ho3+ ions introduced by the addition of Ho2O3 into the photoanode resulted in a 28% enhancement in the power conversion efficiency of DSSC. Such an enhancement in the efficiency may be attributed to the improved lifetime of photo generated excitons as a result of the accelerated intersystem crossing phenomenon. This observation is supported by our photoluminescence (PL) measurements where we could observe a decrease in the photo emission intensity with the addition of Ho2O3. In addition, we have used a low magnetic field of 100 Oe to further enhance the overall efficiency to 5.6%, which in turn proves that the Lorentz force plays a significant role in magnetic field controlled charge transport in DSSC. Finally, we have carried out a transfer matrix model based theoretical simulation for studying the optical properties of the multilayer device stack.

  4. Intramolecular didehydro-Diels-Alder reaction and its impact on the structure-function properties of environmentally sensitive fluorophores.

    Science.gov (United States)

    Brummond, Kay M; Kocsis, Laura S

    2015-08-18

    Reaction discovery plays a vital role in accessing new chemical entities and materials possessing important function.1 In this Account, we delineate our reaction discovery program regarding the [4 + 2] cycloaddition reaction of styrene-ynes. In particular, we highlight our studies that lead to the realization of the diverging reaction mechanisms of the intramolecular didehydro-Diels-Alder (IMDDA) reaction to afford dihydronaphthalene and naphthalene products. Formation of the former involves an intermolecular hydrogen atom abstraction and isomerization, whereas the latter is formed via an unexpected elimination of H2. Forming aromatic compounds by a unimolecular elimination of H2 offers an environmentally benign alternative to typical oxidation protocols. We also include in this Account ongoing work focused on expanding the scope of this reaction, mainly its application to the preparation of cyclopenta[b]naphthalenes. Finally, we showcase the synthetic utility of the IMDDA reaction by preparing novel environmentally sensitive fluorophores. The choice to follow this path was largely influenced by the impact this reaction could have on our understanding of the structure-function relationships of these molecular sensors by taking advantage of a de novo construction and functionalization of the aromatic portion of these compounds. We were also inspired by the fact that, despite the advances that have been made in the construction of small molecule fluorophores, access to rationally designed fluorescent probes or sensors possessing varied and tuned photophysical, spectral, and chemical properties are still needed. To this end, we report our studies to correlate fluorophore structure with photophysical property relationships for a series of solvatochromic PRODAN analogs and viscosity-sensitive cyanoacrylate analogs. The versatility of this de novo strategy for fluorophore synthesis was demonstrated by showing that a number of functional groups could be installed at

  5. The Role of Chronic Psychosocial Stress in Explaining Racial Differences in Stress Reactivity and Pain Sensitivity.

    Science.gov (United States)

    Gordon, Jennifer L; Johnson, Jacqueline; Nau, Samantha; Mechlin, Beth; Girdler, Susan S

    To examine the role of psychosocial factors in mediating the relationship between African American (AA) race and both increased pain sensitivity and blunted stress reactivity. Participants included 133 AA and non-Hispanic white (nHW) individuals (mean [SD] age, 37 [9]) matched for age, sex, and socioeconomic status. Participants underwent mental stress testing (Trier Social Stress Test) while cardiovascular, hemodynamic, and neuroendocrine reactivity were measured. Participants completed questionnaires assessing potential sources of psychosocial stress and were tested for pain responses to cold pain and the temporal summation of heat pulses. Mediation analyses were used to determine the extent to which exposure to psychosocial stress accounted for the observed racial differences in stress reactivity and pain. Chronic stress exposure and reactivity to mental stress was largely similar among AAs and nHWs; however, AAs exhibited heightened pain to both cold (p = .012) and heat (p = .004). Racial differences in the relationship between stress reactivity and pain were also observed: while greater stress reactivity was associated with decreased pain among nHWs, reactivity was either unrelated to or even positively associated with pain among AAs (e.g., r = -.21 among nHWs and r = .41 among AAs for stroke volume reactivity and cold pressor intensity). Adjusting for minor racial differences in chronic psychosocial stress did not change these findings. Accounting for psychosocial factors eliminated racial differences in stress reactivity but not racial differences in sensitivity to experimental pain tasks. Increased exposure to chronic stress may not explain AAs' increased pain sensitivity in laboratory settings.

  6. A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

    CERN Document Server

    Pant, L M; Dinesh, B V; Thomas, R G; Saxena, A; Sawant, Y S; Choudhury, R K

    2002-01-01

    A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from sup 2 sup 4 sup 1 Am- sup 2 sup 3 sup 9 Pu source, fission fragments from sup 2 sup 5 sup 2 Cf and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed.

  7. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis

    Science.gov (United States)

    Wang, Ting; Plecháč, Petr

    2017-12-01

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  8. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis.

    Science.gov (United States)

    Wang, Ting; Plecháč, Petr

    2017-12-21

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  9. Explaining the Stock Market's Reaction to Unemployment News Over the Business Cycle

    NARCIS (Netherlands)

    Driessen, Joost; Kuiper, Ivo

    This paper analyzes the impact of unemployment news on stock markets throughout the business cycle. We show dependence of the reaction to the economic environment by studying the reaction in multiple economic environments that are defined based on both the level and momentum of economic activity.

  10. Magnetic field effects in dye-sensitized solar cells controlled by different cell architecture.

    Science.gov (United States)

    Klein, M; Pankiewicz, R; Zalas, M; Stampor, W

    2016-07-21

    The charge recombination and exciton dissociation are generally recognized as the basic electronic processes limiting the efficiency of photovoltaic devices. In this work, we propose a detailed mechanism of photocurrent generation in dye-sensitized solar cells (DSSCs) examined by magnetic field effect (MFE) technique. Here we demonstrate that the magnitude of the MFE on photocurrent in DSSCs can be controlled by the radius and spin coherence time of electron-hole (e-h) pairs which are experimentally modified by the photoanode morphology (TiO2 nanoparticles or nanotubes) and the electronic orbital structure of various dye molecules (ruthenium N719, dinuclear ruthenium B1 and fully organic squaraine SQ2 dyes). The observed MFE is attributed to magnetic-field-induced spin-mixing of (e-h) pairs according to the Δg mechanism.

  11. Novel heterometallic metal–azido complex synthesized by “one-step” reaction: synthetic strategy and magnetic properties

    International Nuclear Information System (INIS)

    Jiao, Yong-Kun; Li, Xiu-Ping; Zhao, Cui; Wang, Hai-Chao; Xue, Min; Zhao, Jiong-Peng; Liu, Fu-Chen

    2013-01-01

    A novel heterometallic complex, [Ni 2 Mn(N 3 ) 2 (nic) 4 ·(H 2 O) 2 ] n (1) (nic=nicotinate), was obtained by assembling MnCl 2 ·4H 2 O, Ni(NO 3 ) 2 ·6H 2 O, NaN 3 and nicotinic acid with a “one step” synthetic strategy—hydrothermal reaction. The 3D structure of the complex can be described as end-on (EO) azido and syn,syn carboxylates mixed bridged by alternate Ni–Mn–Ni trimers linked by the nicotinate. Dominant ferromagnetic interactions were observed between the Ni II and Mn II ions in the trimer. - Graphical abstract: A novel heterometallic 3D complex [Ni 2 Mn(N 3 ) 2 (nic) 4 ·(H 2 O) 2 ] n (1) (nic=nicotinate) was synthesized by hydrothermal reaction. This complex exhibits interesting structural and magnetic properties. - Highlights: • It is difficult to construct simple coordination complexes with azide as “ligands” to obtain heterometallic metal–azido compounds. • A “one-step” method—hydrothermal reaction— was introduced to avoid the disadvantages of azide mentioned above. • The magnetic property is different with the isostructural homometal–azido complex due to the changed metal center

  12. Group Analysis of Free Convection Flow of a Magnetic Nanofluid with Chemical Reaction

    Directory of Open Access Journals (Sweden)

    Md. Jashim Uddin

    2015-01-01

    Full Text Available A theoretical study of two-dimensional magnetohydrodynamics viscous incompressible free convective boundary layer flow of an electrically conducting, chemically reacting nanofluid from a convectively heated permeable vertical surface is presented. Scaling group of transformations is used in the governing equations and the boundary conditions to determine absolute invariants. A third-order ordinary differential equation which corresponds to momentum conservation and two second-order ordinary differential equations which correspond to energy and nanoparticle volume fraction (species conservation are derived. Our (group analysis indicates that, for the similarity solution, the convective heat transfer coefficient and mass transfer velocity are proportional to x-1/4 whilst the reaction rate is proportional to x-1/2, where x is the axial distance from the leading edge of the plate. The effects of the relevant controlling parameters on the dimensionless velocity, temperature, and nanoparticle volume fraction are examined. The accuracy of the technique we have used was tested by performing comparisons with the results of published work and the results were found to be in good agreement. The present computations indicate that the flow is accelerated and temperature enhanced whereas nanoparticle volume fractions are decreased with increasing order of chemical reaction. Furthermore the flow is strongly decelerated, whereas the nanoparticle volume fraction and temperature are enhanced with increasing magnetic field parameter. Increasing convection-conduction parameter increases velocity and temperatures but has a weak influence on nanoparticle volume fraction distribution. The present study demonstrates the thermal enhancement achieved with nanofluids and also magnetic fields and is of relevance to nanomaterials processing.

  13. Magnetically responsive enzyme powders

    Energy Technology Data Exchange (ETDEWEB)

    Pospiskova, Kristyna, E-mail: kristyna.pospiskova@upol.cz [Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Safarik, Ivo, E-mail: ivosaf@yahoo.com [Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Nanobiotechnology, Institute of Nanobiology and Structural Biology of GCRC, Na Sadkach 7, 370 05 Ceske Budejovice (Czech Republic)

    2015-04-15

    Powdered enzymes were transformed into their insoluble magnetic derivatives retaining their catalytic activity. Enzyme powders (e.g., trypsin and lipase) were suspended in various liquid media not allowing their solubilization (e.g., saturated ammonium sulfate and highly concentrated polyethylene glycol solutions, ethanol, methanol, 2-propanol) and subsequently cross-linked with glutaraldehyde. Magnetic modification was successfully performed at low temperature in a freezer (−20 °C) using magnetic iron oxides nano- and microparticles prepared by microwave-assisted synthesis from ferrous sulfate. Magnetized cross-linked enzyme powders were stable at least for two months in water suspension without leakage of fixed magnetic particles. Operational stability of magnetically responsive enzymes during eight repeated reaction cycles was generally without loss of enzyme activity. Separation of magnetically modified cross-linked powdered enzymes from reaction mixtures was significantly simplified due to their magnetic properties. - Highlights: • Cross-linked enzyme powders were prepared in various liquid media. • Insoluble enzymes were magnetized using iron oxides particles. • Magnetic iron oxides particles were prepared by microwave-assisted synthesis. • Magnetic modification was performed under low (freezing) temperature. • Cross-linked powdered trypsin and lipase can be used repeatedly for reaction.

  14. Magnetism a very short introduction

    CERN Document Server

    Blundell, Stephen J

    2012-01-01

    Magnetism: A Very Short Introduction explains the mysteries and importance of magnetism. For centuries magnetism has been used for various exploits: as a great healer, a navigation aid through compasses, and through motors, generators, and turbines it has given us power. Our understanding of electricity and magnetism, from the work of Galvani, Ampère, Faraday, and Tesla is explored, and how Maxwell and Faraday's work led to the unification of electricity and magnetism is explained. With a discussion of the relationship between magnetism and relativity, quantum magnetism, and its impact on computers and information storage, how magnetism has changed our fundamental understanding of the Universe is shown.

  15. The impact of secondary-task type on the sensitivity of reaction-time based measurement of cognitive load for novices learning surgical skills using simulation.

    Science.gov (United States)

    Rojas, David; Haji, Faizal; Shewaga, Rob; Kapralos, Bill; Dubrowski, Adam

    2014-01-01

    Interest in the measurement of cognitive load (CL) in simulation-based education has grown in recent years. In this paper we present two pilot experiments comparing the sensitivity of two reaction time based secondary task measures of CL. The results suggest that simple reaction time measures are sensitive enough to detect changes in CL experienced by novice learners in the initial stages of simulation-based surgical skills training.

  16. Guided flows in coronal magnetic flux tubes

    Science.gov (United States)

    Petralia, A.; Reale, F.; Testa, P.

    2018-01-01

    Context. There is evidence that coronal plasma flows break down into fragments and become laminar. Aims: We investigate this effect by modelling flows confined along magnetic channels. Methods: We consider a full magnetohydrodynamic (MHD) model of a solar atmosphere box with a dipole magnetic field. We compare the propagation of a cylindrical flow perfectly aligned with the field to that of another flow with a slight misalignment. We assume a flow speed of 200 km s-1 and an ambient magnetic field of 30 G. Results: We find that although the aligned flow maintains its cylindrical symmetry while it travels along the magnetic tube, the misaligned one is rapidly squashed on one side, becoming laminar and eventually fragmented because of the interaction and back-reaction of the magnetic field. This model could explain an observation made by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory of erupted fragments that fall back onto the solar surface as thin and elongated strands and end up in a hedge-like configuration. Conclusions: The initial alignment of plasma flow plays an important role in determining the possible laminar structure and fragmentation of flows while they travel along magnetic channels. Movies are available in electronic form at http://www.aanda.org

  17. Recent results on fusion and direct reactions with weakly bound stable nuclei

    International Nuclear Information System (INIS)

    Shrivastava, A.

    2011-01-01

    Recent measurements of fusion and direct reactions in case of weakly bound stable nuclei at extreme sub-barrier energies using a sensitive off beam technique are presented. First section deals with deep sub-barrier fusion cross-section measurement for 67 Li + 198 Pt followed by the study of fragment capture reaction of 7 Li + 198 Pt. Deviation in the slope of the fusion excitation function, as observed in case of medium heavy systems, is absent in the present asymmetric systems at these low energies. This study shows the absence of fusion hindrance, suggesting modifications in models that explain deep sub-barrier fusion data to incorporate weakly bound asymmetric systems

  18. Monitoring mass transport in heterogeneously catalyzed reactions by field-gradient NMR for assessing reaction efficiency in a single pellet

    Science.gov (United States)

    Buljubasich, L.; Blümich, B.; Stapf, S.

    2011-09-01

    An important aspect in assessing the performance of a catalytically active reactor is the accessibility of the reactive sites inside the individual pellets, and the mass transfer of reactants and products to and from these sites. Optimal design often requires a suitable combination of micro- and macropores in order to facilitate mass transport inside the pellet. In an exothermic reaction, fluid exchange between the pellet and the surrounding medium is enhanced by convection, and often by the occurrence of gas bubbles. Determining mass flow in the vicinity of a pellet thus represents a parameter for quantifying the reaction efficiency and its dependence on time or external reaction conditions. Field gradient Nuclear Magnetic Resonance (NMR) methods are suggested as a tool for providing parameters sensitive to this mass flow in a contact-free and non-invasive way. For the example of bubble-forming hydrogen peroxide decomposition in an alumina pellet, the dependence of the mean-squared displacement of fluid molecules on spatial direction, observation time and reaction time is presented, and multi-pulse techniques are employed in order to separate molecular displacements from coherent and incoherent motion on the timescale of the experiment. The reaction progress is followed until the complete decomposition of H 2O 2.

  19. Radiation dosimetry using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Olsson, L.E.

    1991-01-01

    A new dosimetry system for 3D dose distribution measurements based on the Fricke dosimeter and magnetic resonance imaging (MRI) has been developed. The dosimeter consists of a ferrous sulphate solution incorporated in an agarose gel, which together constitute the dosimeter gel. The absorbed dose to the gel is measured by means of the proton spin-lattice relaxation rate, 1/T1 in an MR scanner. The dose distribution to an arbitrary slice within a dosimeter gel phantom can thus be determined. The chemical yield of the dosimeter gel is significantly higher than that of the for Fricke solution, and is strongly dependent of the initial ferrous sulphate concentration, assuming that the gel is bubbled with oxygen during preparation. A gel of 1.5 mM [Fe 2+ ] and 50 mM [H 2 SO 4 ] has a sensitivity of 0.108 s -1 Gy -1 and is linear up to 50 Gy. The dosimeter gel has uniform dose response over large volumes. Above 50 mM[H 2 SO 4 ] the yield increases only slightly, but the gel strength decreases and results in gel phantoms with non-uniform dose response. Below 50 mM[H 2 SO 4 ] the sensitivity of the dosimeter falls rapidly due to the decreased relaxivity of the ferric ions. The high chemical yield can be explained by a chain reaction and a reaction scheme is accordingly proposed. The dosimeter gel shows no dependence on dose rate or radiation quality and can be regarded as water-equivalent with respect to the interaction of the radiation. The diffusion coefficient of the ferric ions in the agarose gel is 1.19x10 -2 cm 2 /h. The diffusion blurs the dosimeteric image, but poses only a minor problem if the MR measurements are completed within the first two hours after irradiation. Dose distribution data from external radiation therapy units have been determined using the dosimeter gel and MRI with good accuracy, but the precision is poor, about 5-10%. (au) (84 refs.)

  20. Evaluation of multiplex polymerase chain reaction as an alternative to conventional antibiotic sensitivity test

    Directory of Open Access Journals (Sweden)

    K. Rathore

    2018-04-01

    Full Text Available Aim: This study was designed to evaluate the potential of the use of multiplex polymerase chain reaction (PCR as an alternative to conventional antibiotic sensitivity test. Materials and Methods: Isolates of Staphylococcus aureus (total = 36 from clinical cases presented to Teaching Veterinary Clinical Complex of College of Veterinary and Animal Sciences (CVAS, Navania, Udaipur, were characterized by morphological, cultural, and biochemical methods. Then, the isolates were further subjected to molecular characterization by PCR targeting S. aureus-specific sequence (107 bp. Phenotypic antibiotic sensitivity pattern was analyzed by Kirby Bauer disc diffusion method against 11 commonly used antibiotics in veterinary medicine in and around Udaipur region. The genotypic antibiotic sensitivity pattern was studied against methicillin, aminoglycosides, and tetracycline targeting the gene mecA, aacA-aphD, and tetK by multiplex PCR. Results: There was 100% correlation between the phenotype and genotype of aminoglycoside resistance, more than 90% correlation for methicillin resistance, and 58.3% in the case tetracycline resistance. Conclusion: As there is a good correlation between phenotype and genotype of antibiotic resistance, multiplex PCR can be used as an alternative to the conventional antibiotic susceptibility testing, as it can give a rapid and true prediction of antibiotic sensitivity pattern.

  1. The Capacitive Magnetic Field Sensor

    Science.gov (United States)

    Zyatkov, D. O.; Yurchenko, A. V.; Balashov, V. B.; Yurchenko, V. I.

    2016-01-01

    The results of a study of sensitive element magnetic field sensor are represented in this paper. The sensor is based on the change of the capacitance with an active dielectric (ferrofluid) due to the magnitude of magnetic field. To prepare the ferrofluid magnetic particles are used, which have a followingdispersion equal to 50 brand 5BDSR. The dependence of the sensitivity of the capacitive element from the ferrofluid with different dispersion of magnetic particles is considered. The threshold of sensitivity and sensitivity of a measuring cell with ferrofluid by a magnetic field was determined. The experimental graphs of capacitance change of the magnitude of magnetic field are presented.

  2. Magnetic field sensor based on cascaded microfiber coupler with magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Lianmin; Su, Delong; Wang, Zhaofang [College of Science, University of Shanghai for Science and Technology, Shanghai 200093 (China); Pu, Shengli, E-mail: shlpu@usst.edu.cn [College of Science, University of Shanghai for Science and Technology, Shanghai 200093 (China); Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093 (China); Zeng, Xianglong [The Key Lab of Specialty Fiber Optics and Optical Access Network, Shanghai University, Shanghai 200072 (China); Lahoubi, Mahieddine [Laboratory L.P.S., Department of Physics, Faculty of Sciences, Badji-Mokhtar Annaba University, Annaba 23000 (Algeria)

    2016-09-07

    A kind of magnetic field sensor based on cascaded microfiber coupler with magnetic fluid is proposed and experimentally demonstrated. The magnetic fluid is utilized as the cladding of the fused regions of the cascaded microfiber coupler. As the interference valley wavelength of the sensing structure is sensitive to the ambient variation, considering the magnetic-field-dependent refractive index of magnetic fluid, the proposed structure is employed for magnetic field sensing. The effective coupling length for each coupling region of the as-fabricated cascaded microfiber coupler is 6031 μm. The achieved sensitivity is 125 pm/Oe, which is about three times larger than that of the previously similar structure based on the single microfiber coupler. Experimental results indicate that the sensing sensitivity can be easily improved by increasing the effective coupling length or cascading more microfiber couplers. The proposed magnetic field sensor is attractive due to its low cost, immunity to electromagnetic interference, as well as high sensitivity, which also has the potentials in other tunable all-fiber photonic devices, such as filter.

  3. Development of a highly sensitive current and position monitor with HTS squids and an HTS magnetic shield

    International Nuclear Information System (INIS)

    Watanabe, T.; Ikeda, T.; Kase, M.; Yano, Y.; Watanabe, S.; Sasaki, Y.; Kawaguchi, T.

    2005-01-01

    A highly sensitive current and position monitor with HTS (High-Temperature Superconducting) SQUIDs (Superconducting QUantum Interference Device) and an HTS magnetic shield for the measurement of the intensity of faint beams, such as a radioisotope beam, has been developed for the RIKEN RI beam factory project. The HTS magnetic shield and the HTS current sensor including the HTS SQUID are cooled by a low-vibration pulse-tube refrigerator. Both the HTS magnetic shield and the HTS current sensor were fabricated by dip-coating a thin Bi 2 -Sr 2 -Ca 2 -Cu 3 -O x (Bi-2223) layer on 99.9% MgO ceramic substrates. The HTS technology enables us to develop a system equipped with a downsized and highly sensitive current monitor. Recently, a prototype system was completed and installed in the beam transport line of the RIKEN Ring Cyclotron to measure the DC-current of high-energy heavy-ion beams. As a result, we succeeded in measuring the intensity of the 600 nA 40 Ar 17+ beam (95 MeV/u). We describe the present status of the monitor system and the results of the beam measurements. (author)

  4. Neutron measurements in the FRX-C/LSM magnetic compression experiment

    International Nuclear Information System (INIS)

    Chrien, R.E.; Baron, M.H.

    1989-01-01

    Neutron measurements are being pursued as an ion temperature diagnostic in the FRX-C/LSM Magnetic Compression Experiment. One can easily see that the d-d neutron emission is a sensitive measure of ion heating during adiabatic magnetic compression of FRCs. The reaction rate may be written as R = (1/2) n N left-angle σv right-angle, where n and N are the deuterium density and inventory. The fusion reactivity varies as left-angle σv right-angle ∝ T 5.6 for T ≅ 1 keV. For adiabatic compression, n ∝ B 1.2 and T ∝ B 0.8 so R ∝ B 5.7 in the absence of losses. The neutron yield is also sensitive to the time duration that the plasma remains near its peak temperature. 4 refs., 4 figs

  5. Photochemical primary process of photo-Fries rearrangement reaction of 1-naphthyl acetate as studied by MFE probe.

    Science.gov (United States)

    Gohdo, Masao; Takamasu, Tadashi; Wakasa, Masanobu

    2011-01-14

    Photo-Fries rearrangement reactions of 1-naphthyl acetate (NA) in n-hexane and in cyclohexane were studied by the magnetic field effect probe (MFE probe) under magnetic fields (B) of 0 to 7 T. Transient absorptions of the 1-naphthoxyl radical, T-T absorption of NA, and a short-lifetime intermediate (τ = 24 ns) were observed by a nanosecond laser flash photolysis technique. In n-hexane, the yield of escaped 1-naphthoxyl radicals dropped dramatically upon application of a 3 mT field, but then the yield increased with increasing B for 3 mT < B≤ 7 T. These observed MFEs can be explained by the hyperfine coupling and the Δg mechanisms through the singlet radical pair. The fact that MFEs were observed for the present photo-Fries rearrangement reaction indicates the presence of a singlet radical pair intermediate with a lifetime as long as several tens of nanoseconds.

  6. Flow injection determination of diclofenac sodium based on its sensitizing effect on the chemiluminescent reaction of acidic potassium permanganate-formaldehyde.

    Science.gov (United States)

    Song, Jingjing; Sun, Pulv; Ji, Zhongling; Li, Jianguo

    2015-02-01

    A sensitive and simple chemiluminescent (CL) method for the determination of diclofenac sodium has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between formaldehyde and acidic potassium permanganate. A calibration curve is constructed for diclofenac sodium under optimized experimental parameters over the range 0.040-5.0 µg/mL and the limit of detection is 0.020 µg/mL (3σ). The inter-assay relative standard deviation for 0.040 µg/mL diclofenac sodium (n = 11) is 2.0%. This method is rapid, sensitive, simple, and shows good selectivity and reproducibility. The proposed method has been successfully applied to the determination of the studied diclofenac sodium in pharmaceutical preparations with satisfactory results. Furthermore, the possible mechanism for the CL reaction has been discussed in detail on the basis of UV and CL spectra. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  8. Early Magnetic Resonance Detection of Natalizumab-Related Progressive Multifocal Leukoencephalopathy in a Patient with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Guglielmo Manenti

    2013-01-01

    Full Text Available Diagnosis of progressive multifocal leukoencephalopathy is usually based on the clinical presentation, on the demonstration of the brain lesions at the magnetic resonance imaging examination, and on the detection of the JC virus DNA in the cerebrospinal fluid with high sensitive polymerase chain reaction. The role of magnetic resonance imaging specifically in natalizumab-associated progressive multifocal leukoencephalopathy is strengthening, and it is gaining importance not only as an irreplaceable diagnostic tool but also as a surveillance and risk stratifying tool in treated patients. While other imaging techniques such as computed tomography lack sensitivity and specificity, magnetic resonance performed with morphological and functional sequences offers clinicians the possibility to early identify the stage of the disease and the emergence of an immune reconstitution inflammatory syndrome after natalizumab blood removal plasmapheresis.

  9. A sensitivity analysis method for the body segment inertial parameters based on ground reaction and joint moment regressor matrices.

    Science.gov (United States)

    Futamure, Sumire; Bonnet, Vincent; Dumas, Raphael; Venture, Gentiane

    2017-11-07

    This paper presents a method allowing a simple and efficient sensitivity analysis of dynamics parameters of complex whole-body human model. The proposed method is based on the ground reaction and joint moment regressor matrices, developed initially in robotics system identification theory, and involved in the equations of motion of the human body. The regressor matrices are linear relatively to the segment inertial parameters allowing us to use simple sensitivity analysis methods. The sensitivity analysis method was applied over gait dynamics and kinematics data of nine subjects and with a 15 segments 3D model of the locomotor apparatus. According to the proposed sensitivity indices, 76 segments inertial parameters out the 150 of the mechanical model were considered as not influent for gait. The main findings were that the segment masses were influent and that, at the exception of the trunk, moment of inertia were not influent for the computation of the ground reaction forces and moments and the joint moments. The same method also shows numerically that at least 90% of the lower-limb joint moments during the stance phase can be estimated only from a force-plate and kinematics data without knowing any of the segment inertial parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Electrochemical biotin detection based on magnetic beads and a new magnetic flow cell for screen printed electrode.

    Science.gov (United States)

    Biscay, Julien; González García, María Begoña; Costa García, Agustín

    2015-01-01

    The use of the first flow-cell for magnetic assays with an integrated magnet is reported here. The flow injection analysis system (FIA) is used for biotin determination. The reaction scheme is based on a one step competitive assay between free biotin and biotin labeled with horseradish peroxidase (B-HRP). The mixture of magnetic beads modified with streptavidin (Strep-MB), biotin and B-HRP is left 15 min under stirring and then a washing step is performed. After that, 100 μL of the mixture is injected and after 30s 100 μL of 3,3',5,5'-Tetramethylbenzidine (TMB) is injected and the FIAgram is recorded applying a potential of -0.2V. The linear range obtained is from 0.01 to 1 nM of biotin and the sensitivity is 758 nA/nM. The modification and cleaning of the electrode are performed in an easy way due to the internal magnet of the flow cell. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A comparison of the sensitivities of detection of Plasmodium falciparum gametocytes by magnetic fractionation, thick blood film microscopy, and RT-PCR

    OpenAIRE

    Karl, Stephan; Davis, Timothy ME; St-Pierre, Tim G

    2009-01-01

    Abstract Background The magnetic properties of Plasmodium-infected erythrocytes have been exploited for different clinical and research purposes. A recent study in a rural clinical setting in Papua New Guinea has demonstrated that Plasmodium falciparum gametocyte detection is facilitated by magnetic deposition microscopy but no study has yet determined the relative sensitivity and limit of detection of a magnetic fractionation technique. The present study compares the detection limit and sens...

  12. Molecular packing and magnetic properties of lithium naphthalocyanine crystals: hollow channels enabling permeability and paramagnetic sensitivity to molecular oxygen

    Science.gov (United States)

    Pandian, Ramasamy P.; Dolgos, Michelle; Marginean, Camelia; Woodward, Patrick M.; Hammel, P. Chris; Manoharan, Periakaruppan T.; Kuppusamy, Periannan

    2009-01-01

    The synthesis, structural framework, magnetic and oxygen-sensing properties of a lithium naphthalocyanine (LiNc) radical probe are presented. LiNc was synthesized in the form of a microcrystalline powder using a chemical method and characterized by electron paramagnetic resonance (EPR) spectroscopy, magnetic susceptibility, powder X-ray diffraction analysis, and mass spectrometry. X-Ray powder diffraction studies revealed a structural framework that possesses long, hollow channels running parallel to the packing direction. The channels measured approximately 5.0 × 5.4 Å2 in the two-dimensional plane perpendicular to the length of the channel, enabling diffusion of oxygen molecules (2.9 × 3.9 Å2) through the channel. The powdered LiNc exhibited a single, sharp EPR line under anoxic conditions, with a peak-to-peak linewidth of 630 mG at room temperature. The linewidth was sensitive to surrounding molecular oxygen, showing a linear increase in pO2 with an oxygen sensitivity of 31.2 mG per mmHg. The LiNc microcrystals can be further prepared as nano-sized crystals without the loss of its high oxygen-sensing properties. The thermal variation of the magnetic properties of LiNc, such as the EPR linewidth, EPR intensity and magnetic susceptibility revealed the existence of two different temperature regimes of magnetic coupling and hence differing columnar packing, both being one-dimensional antiferromagnetic chains but with differing magnitudes of exchange coupling constants. At a temperature of ∼50 K, LiNc crystals undergo a reversible phase transition. The high degree of oxygen-sensitivity of micro- and nano-sized crystals of LiNc, combined with excellent stability, should enable precise and accurate measurements of oxygen concentration in biological systems using EPR spectroscopy. PMID:19809598

  13. Application of Monte Carlo Methods to Perform Uncertainty and Sensitivity Analysis on Inverse Water-Rock Reactions with NETPATH

    Energy Technology Data Exchange (ETDEWEB)

    McGraw, David [Desert Research Inst. (DRI), Reno, NV (United States); Hershey, Ronald L. [Desert Research Inst. (DRI), Reno, NV (United States)

    2016-06-01

    Methods were developed to quantify uncertainty and sensitivity for NETPATH inverse water-rock reaction models and to calculate dissolved inorganic carbon, carbon-14 groundwater travel times. The NETPATH models calculate upgradient groundwater mixing fractions that produce the downgradient target water chemistry along with amounts of mineral phases that are either precipitated or dissolved. Carbon-14 groundwater travel times are calculated based on the upgradient source-water fractions, carbonate mineral phase changes, and isotopic fractionation. Custom scripts and statistical code were developed for this study to facilitate modifying input parameters, running the NETPATH simulations, extracting relevant output, postprocessing the results, and producing graphs and summaries. The scripts read userspecified values for each constituent’s coefficient of variation, distribution, sensitivity parameter, maximum dissolution or precipitation amounts, and number of Monte Carlo simulations. Monte Carlo methods for analysis of parametric uncertainty assign a distribution to each uncertain variable, sample from those distributions, and evaluate the ensemble output. The uncertainty in input affected the variability of outputs, namely source-water mixing, phase dissolution and precipitation amounts, and carbon-14 travel time. Although NETPATH may provide models that satisfy the constraints, it is up to the geochemist to determine whether the results are geochemically reasonable. Two example water-rock reaction models from previous geochemical reports were considered in this study. Sensitivity analysis was also conducted to evaluate the change in output caused by a small change in input, one constituent at a time. Results were standardized to allow for sensitivity comparisons across all inputs, which results in a representative value for each scenario. The approach yielded insight into the uncertainty in water-rock reactions and travel times. For example, there was little

  14. Magnetically levitated railway with common reaction rail for a linear motor drive and an electro dynamic side guidance arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, R

    1977-04-07

    The invention concerns a magnetically levitated railway with common reaction rail for the linear motor drive and the electrical side guidance arrangement. While the electro-dynamic hovering process requires a high electrical conductivity of the reaction rails in order to reduce eddy current losses, these should show a relatively high resistance for the asynchronous linear motor to reduce losses of propelling force. These contradictory requirements can be fulfilled for a common reaction rail made of homogeneous material of high electrical conductivity according to the invention, by providing slits at right angles to the driving axis in the part of the reaction rail allocated to the linear motor. Thus the guidance system retains a low ohmic resistance, while the part of the reaction rail allocated to the windings of the linear motor has a relatively low ohmic secondary resistance, by which the border and end effects which reduce the propelling force can be appreciably reduced.

  15. The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type

    International Nuclear Information System (INIS)

    Kawaguchi, Toshiro; Yoshimura, Atsushi

    1999-01-01

    There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation was done on the relationship between ionization current by 137 Cs and the applied voltage. For actual measurement, ionizations by low dose γ ray derived from KCl which containing 40 K in a small amount and by Rn at the fine and rainy days were measured. The exposure rate by KCl (500 g bottle) was found to be 12.7 x 10 -10 C/kg·h with the background value of 9.8 x 10 -10 . Rn concentrations in the air were 112.3 and 18.34 Bq/m 3 for 1 hr in the rainy and fine day, respectively, in Fukuoka City. (K.H.)

  16. Unifying Exchange Sensitivity in Transition-Metal Spin-State Ordering and Catalysis through Bond Valence Metrics.

    Science.gov (United States)

    Gani, Terry Z H; Kulik, Heather J

    2017-11-14

    Accurate predictions of spin-state ordering, reaction energetics, and barrier heights are critical for the computational discovery of open-shell transition-metal (TM) catalysts. Semilocal approximations in density functional theory, such as the generalized gradient approximation (GGA), suffer from delocalization error that causes them to overstabilize strongly bonded states. Descriptions of energetics and bonding are often improved by introducing a fraction of exact exchange (e.g., erroneous low-spin GGA ground states are instead correctly predicted as high-spin with a hybrid functional). The degree of spin-splitting sensitivity to exchange can be understood based on the chemical composition of the complex, but the effect of exchange on reaction energetics within a single spin state is less well-established. Across a number of model iron complexes, we observe strong exchange sensitivities of reaction barriers and energies that are of the same magnitude as those for spin splitting energies. We rationalize trends in both reaction and spin energetics by introducing a measure of delocalization, the bond valence of the metal-ligand bonds in each complex. The bond valence thus represents a simple-to-compute property that unifies understanding of exchange sensitivity for catalytic properties and spin-state ordering in TM complexes. Close agreement of the resulting per-metal-organic-bond sensitivity estimates, together with failure of alternative descriptors demonstrates the utility of the bond valence as a robust descriptor of how differences in metal-ligand delocalization produce differing relative energetics with exchange tuning. Our unified description explains the overall effect of exact exchange tuning on the paradigmatic two-state FeO + /CH 4 reaction that combines challenges of spin-state and reactivity predictions. This new descriptor-sensitivity relationship provides a path to quantifying how predictions in transition-metal complex screening are sensitive to the

  17. Physics of magnetic nanostructures

    CERN Document Server

    Owens, Frank J

    2015-01-01

    This book discusses how the important properties of materials such as the cohesive energy, and the electronic and vibrational structures are affected when materials have at least one length in the nanometer range. The author uses relatively simple models of the solid state to explain why these changes in the size and dimension in the nanometer regime occur. The text also reviews the physics of magnetism and experimental methods of measuring magnetic properties necessary to understanding how nanosizing affects magnetism. Various kinds of magnetic structures are presented by the author in order to explain how nanosizing influences their magnetic properties. The book also presents potential and actual applications of nanomaterials in the fields of medicine and computer data storage.

  18. Detection sensitivity of fluorine in dental enamel through the 19F(p,psup(')γ)19F reaction

    International Nuclear Information System (INIS)

    Papper, C.S.; Chittleborough, G.; Kennett, S.R.; Chaudhri, M.A.

    1978-01-01

    The total cross sections for production of 109 and 197 keV gamma rays in the reaction 19 F(p,psup(')γ) 19 F have been measured, over a range of energies up to 4.3 MeV. From these cross sections, the thick detection sensitivities for a uniform distribution of fluorine in dental enamel have been calculated

  19. LSENS: A General Chemical Kinetics and Sensitivity Analysis Code for homogeneous gas-phase reactions. Part 1: Theory and numerical solution procedures

    Science.gov (United States)

    Radhakrishnan, Krishnan

    1994-01-01

    LSENS, the Lewis General Chemical Kinetics and Sensitivity Analysis Code, has been developed for solving complex, homogeneous, gas-phase chemical kinetics problems and contains sensitivity analysis for a variety of problems, including nonisothermal situations. This report is part 1 of a series of three reference publications that describe LENS, provide a detailed guide to its usage, and present many example problems. Part 1 derives the governing equations and describes the numerical solution procedures for the types of problems that can be solved. The accuracy and efficiency of LSENS are examined by means of various test problems, and comparisons with other methods and codes are presented. LSENS is a flexible, convenient, accurate, and efficient solver for chemical reaction problems such as static system; steady, one-dimensional, inviscid flow; reaction behind incident shock wave, including boundary layer correction; and perfectly stirred (highly backmixed) reactor. In addition, the chemical equilibrium state can be computed for the following assigned states: temperature and pressure, enthalpy and pressure, temperature and volume, and internal energy and volume. For static problems the code computes the sensitivity coefficients of the dependent variables and their temporal derivatives with respect to the initial values of the dependent variables and/or the three rate coefficient parameters of the chemical reactions.

  20. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, M.; Sakamoto, S.; Ishii, K. [Division of Neuroimaging Research, Hyogo Institute for Aging Brain and Cognitive Disorders (Japan); Imamura, T.; Kazui, H.; Mori, E. [Division of Clinical Neurosciences, Hyogo Institute for Aging Brain and Cognitive Disorders, Hyogo (Japan)

    2002-03-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  1. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsui, M.; Sakamoto, S.; Ishii, K.; Imamura, T.; Kazui, H.; Mori, E.

    2002-01-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  2. Electron spin interactions in chemistry and biology fundamentals, methods, reactions mechanisms, magnetic phenomena, structure investigation

    CERN Document Server

    Likhtenshtein, Gertz

    2016-01-01

    This book presents the versatile and pivotal role of electron spin interactions in nature. It provides the background, methodologies and tools for basic areas related to spin interactions, such as spin chemistry and biology, electron transfer, light energy conversion, photochemistry, radical reactions, magneto-chemistry and magneto-biology. The book also includes an overview of designing advanced magnetic materials, optical and spintronic devices and photo catalysts. This monograph appeals to scientists and graduate students working in the areas related to spin interactions physics, biophysics, chemistry and chemical engineering.

  3. Effect of a weak magnetic field on the Mizoroki–Heck coupling reaction in the presence of wicker-like palladium-poly(N-vinylpyrrolidone)-iron nanocatalyst

    Energy Technology Data Exchange (ETDEWEB)

    Rafiee, Ezzat, E-mail: ezzat_rafiee@yahoo.com [Department of Inorganic Chemistry, Faculty of Chemistry, Razi University, Kermanshah 67149 (Iran, Islamic Republic of); Institute of Nano Science and Nano Technology, Razi University, Kermanshah 67149 (Iran, Islamic Republic of); Joshaghani, Mohammad [Department of Inorganic Chemistry, Faculty of Chemistry, Razi University, Kermanshah 67149 (Iran, Islamic Republic of); Institute of Nano Science and Nano Technology, Razi University, Kermanshah 67149 (Iran, Islamic Republic of); Abadi, Parvaneh Ghaderi-Shekhi [Institute of Nano Science and Nano Technology, Razi University, Kermanshah 67149 (Iran, Islamic Republic of)

    2016-06-15

    The wicker-like Pd-PVP-Fe (palladium-poly(N-vinylpyrrolidone)-iron) was synthesized by the external magnetic field (EMF). The Pd-based catalyst with nano and the face-centered cubic (fcc) structure was obtained at room temperature without using any additive. The resulting composite was characterized. The results show that EMF has a great influence on morphology, particle size, and crystalline structure of the Pd-PVP-Fe composite. The resulting composite (Pd-PVP-Fe), was found to be an effective catalyst for the Mizoroki–Heck reaction while is exposed to EMF with the intensity at 486 µT. The reused catalyst for at least five repeating cycles, shows excellent activity. - Highlights: • The wicker-like Pd-PVP-Fe nanocatalyst was synthesized via external magnetic field. • The resulting catalyst composite was characterized. • The C–C coupling reaction was carried out at magnetic field and room temperature. • Magnetic field affects on the morphology and size of the catalyst. • The catalyst could be reused without significant degradation in activity.

  4. Correlation between radiation damage and magnetic properties in reactor vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Kempf, R.A., E-mail: kempf@cnea.gov.ar [División Caracterización, GCCN, CAC-CNEA (Argentina); Sacanell, J. [Departamento Física de la Materia Condensada, GIyA, CAC-CNEA, CONICET (Argentina); Milano, J. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Guerra Méndez, N. [Departamento Física de la Materia Condensada, GIyA, CAC-CNEA, CONICET (Argentina); Winkler, E.; Butera, A. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Troiani, H. [División Física de Metales, CAB-CNEA and Instituto Balseiro (UNCU), CONICET (Argentina); Saleta, M.E. [División Resonancias Magnéticas, CAB-CNEA, CONICET (Argentina); Fortis, A.M. [Departamento Estructura y Comportamiento. Gerencia Materiales-GAEN, CAC-CNEA (Argentina)

    2014-02-01

    Since reactor pressure vessel steels are ferromagnetic, provide a convenient means to monitor changes in the mechanical properties of the material upon irradiation with high energy particles, by measuring their magnetic properties. Here, we discuss the correlation between mechanical and magnetic properties and microstructure, by studying the flux effect on the nuclear pressure vessel steel used in reactors currently under construction in Argentina. Charpy-V notched specimens of this steel were irradiated in the RA1 experimental reactor at 275 °C with two lead factors (LFs), 93 and 183. The magnetic properties were studied by means of DC magnetometry and ferromagnetic resonance. The results show that the coercive field and magnetic anisotropy spatial distribution are sensitive to the LF and can be explained by taking into account the evolution of the microstructure with this parameter. The saturation magnetization shows a dominant dependence on the accumulated damage. Consequently, the mentioned techniques are suitable to estimate the degradation of the reactor vessel steel.

  5. Bats respond to very weak magnetic fields.

    Directory of Open Access Journals (Sweden)

    Lan-Xiang Tian

    Full Text Available How animals, including mammals, can respond to and utilize the direction and intensity of the Earth's magnetic field for orientation and navigation is contentious. In this study, we experimentally tested whether the Chinese Noctule, Nyctalus plancyi (Vespertilionidae can sense magnetic field strengths that were even lower than those of the present-day geomagnetic field. Such field strengths occurred during geomagnetic excursions or polarity reversals and thus may have played an important role in the evolution of a magnetic sense. We found that in a present-day local geomagnetic field, the bats showed a clear preference for positioning themselves at the magnetic north. As the field intensity decreased to only 1/5th of the natural intensity (i.e., 10 μT; the lowest field strength tested here, the bats still responded by positioning themselves at the magnetic north. When the field polarity was artificially reversed, the bats still preferred the new magnetic north, even at the lowest field strength tested (10 μT, despite the fact that the artificial field orientation was opposite to the natural geomagnetic field (P<0.05. Hence, N. plancyi is able to detect the direction of a magnetic field even at 1/5th of the present-day field strength. This high sensitivity to magnetic fields may explain how magnetic orientation could have evolved in bats even as the Earth's magnetic field strength varied and the polarity reversed tens of times over the past fifty million years.

  6. Mechanical Enhancement of Sensitivity in Natural Rubber Using Electrolytic Polymerization Aided by a Magnetic Field and MCF for Application in Haptic Sensors.

    Science.gov (United States)

    Shimada, Kunio; Saga, Norihiko

    2016-09-18

    Sensors are essential to the fulfillment of every condition of haptic technology, and they need simultaneously to sense shear stress as well as normal force, and temperature. They also must have a strong and simple structure, softness, and large extension. To achieve these conditions simultaneously, we enhanced the sensitivity of sensors utilizing natural rubber (NR)-latex through the application of electrolytic polymerization focused on the isoprene C=C bonds in natural rubbers such as NR-latex, and then applied a magnetic field and magnetic compound fluid (MCF) as magnetically responsive fluid. When an electric field alone was used in the rubber, the effect of electrolytic polymerization was very small compared to the effect in well-known conductive polymer solution such as plastic. The MCF developed by Shimada in 2001 involved magnetite and metal particles, and acts as a filler in NR-latex. By utilizing the magnetic, electric fields and the MCF, we aligned the electrolytically polymerized C=C along the magnetic field line with the magnetic clusters formed by the aggregation of magnetite and metal particles so as to enhance the effect of electrolytic polymerization. We then demonstrated the effectiveness of the new method of rubber vulcanization on the sensitivity of the rubber by experimentally investigating its electric and dynamic characteristics.

  7. Mechanical Enhancement of Sensitivity in Natural Rubber Using Electrolytic Polymerization Aided by a Magnetic Field and MCF for Application in Haptic Sensors

    Directory of Open Access Journals (Sweden)

    Kunio Shimada

    2016-09-01

    Full Text Available Sensors are essential to the fulfillment of every condition of haptic technology, and they need simultaneously to sense shear stress as well as normal force, and temperature. They also must have a strong and simple structure, softness, and large extension. To achieve these conditions simultaneously, we enhanced the sensitivity of sensors utilizing natural rubber (NR-latex through the application of electrolytic polymerization focused on the isoprene C=C bonds in natural rubbers such as NR-latex, and then applied a magnetic field and magnetic compound fluid (MCF as magnetically responsive fluid. When an electric field alone was used in the rubber, the effect of electrolytic polymerization was very small compared to the effect in well-known conductive polymer solution such as plastic. The MCF developed by Shimada in 2001 involved magnetite and metal particles, and acts as a filler in NR-latex. By utilizing the magnetic, electric fields and the MCF, we aligned the electrolytically polymerized C=C along the magnetic field line with the magnetic clusters formed by the aggregation of magnetite and metal particles so as to enhance the effect of electrolytic polymerization. We then demonstrated the effectiveness of the new method of rubber vulcanization on the sensitivity of the rubber by experimentally investigating its electric and dynamic characteristics.

  8. Characteristics of a Bulk High-Critical Temperature Superconductor Fabricated by the Shock Compaction Method: Possible Use as a Highly Sensitive Magnetic Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, H [Interdisci. Grad. School of Sci. and Engi., Grad. School of Kinki University, Higashi-Osaka, Osaka 577-8502 (Japan); Maeji, Y [Interdisci. Grad. School of Sci. and Engi., Grad. School of Kinki University, Higashi-Osaka, Osaka 577-8502 (Japan); Yamagata, K [Relia. Eval. Technol. Center, Nitto Denko Corp., Onomichi, Hiroshima 722-0212 (Japan); Itoh, M [Interdisci. Grad. School of Sci. and Engi., Grad. School of Kinki University, Higashi-Osaka, Osaka 577-8502 (Japan); Kezuka, H [Faculty of Bionics, Tokyo University of Technol., Hachioji, Tokyo 192-0982 (Japan); Kikuchi, M [Kansen Fukushi Research Center, Tohoku Fukushi University Sendai, Miyagi 989-3201 (Japan); Atou, T [Insti. for Mate. Research, Tohoku University Sendai, Miyagi 980-8577 (Japan); Kawasaki, M [Insti. for Mate. Research, Tohoku University Sendai, Miyagi 980-8577 (Japan); Fukuoka, K [Insti. for Mate. Research, Tohoku University Sendai, Miyagi 980-8577 (Japan)

    2006-06-01

    A magnetic sensor, constructed of bulk Bi-Pb-Sr-Ca-Cu-O (BPSCCO), was fabricated by use of the shock compaction method, employing a propellant gun-system, and then sintered under through use of an electronic furnace. The specimen as a magnetic sensor was maintained in the superconducting state at 77.4 K, under a current density J of approximately 40 A/cm{sup 2} in the absence of an excitation magnetic field B{sub ex}. The superconducting state was then broken and the specimen exposed to a B{sub ex} value of 40x10{sup -4} T. That is, the resistance R{sub meas} of the specimen occurred when exposed to 40x10{sup -4} T under a constant J of 40 A/cm{sup 2}. The magnetic sensitivity S of the specimen was approximately 13 %/(10{sup -4} T) over the range of measurement of the magnetic field B{sub meas} from 0 to {+-}5x10{sup -4} T, under a constant 40x10{sup -4} T for the value of B{sub ex}, being approximately 13 times greater than that of a giant magnetoresistance (GMR) sensor. It was, consequently, determined that it was possible to apply the bulk BPSCCO specimen as a highly sensitive magnetic sensor.

  9. Characteristics of a Bulk High-Critical Temperature Superconductor Fabricated by the Shock Compaction Method: Possible Use as a Highly Sensitive Magnetic Sensor

    International Nuclear Information System (INIS)

    Fujita, H; Maeji, Y; Yamagata, K; Itoh, M; Kezuka, H; Kikuchi, M; Atou, T; Kawasaki, M; Fukuoka, K

    2006-01-01

    A magnetic sensor, constructed of bulk Bi-Pb-Sr-Ca-Cu-O (BPSCCO), was fabricated by use of the shock compaction method, employing a propellant gun-system, and then sintered under through use of an electronic furnace. The specimen as a magnetic sensor was maintained in the superconducting state at 77.4 K, under a current density J of approximately 40 A/cm 2 in the absence of an excitation magnetic field B ex . The superconducting state was then broken and the specimen exposed to a B ex value of 40x10 -4 T. That is, the resistance R meas of the specimen occurred when exposed to 40x10 -4 T under a constant J of 40 A/cm 2 . The magnetic sensitivity S of the specimen was approximately 13 %/(10 -4 T) over the range of measurement of the magnetic field B meas from 0 to ±5x10 -4 T, under a constant 40x10 -4 T for the value of B ex , being approximately 13 times greater than that of a giant magnetoresistance (GMR) sensor. It was, consequently, determined that it was possible to apply the bulk BPSCCO specimen as a highly sensitive magnetic sensor

  10. Numerical simulations to model laser-driven coil-capacitor targets for generation of kilo-Tesla magnetic fields

    Directory of Open Access Journals (Sweden)

    F. Schillaci

    2018-02-01

    Full Text Available A coil-capacitor target is modeled using FEM simulations and analytical calculations, which allow to explain the time evolution of such complex target during magnetic field production driven by the flow of an extremely high current generated through the interaction with a high power laser. The numerical model includes a detailed study of the magnetic field produced by the coil-capacitor target, both in the static and transient cases, as well as magnetic force and Joule heating. The model is validated by experimental data reported in literature and can be of interest for several applications. As an example, the combination of two synchronized nanosecond lasers with the purpose of producing a plasma responsible of the proton-boron (p+ + 11B → 8.5 MeV + 3α fusion reaction, and energizing two multi-turn coils with the main purpose of confining such a plasma could enhance the reaction rate. The preliminary conceptual design of a magnetic mirror configuration to be used for confining protons and boron ions up to a few MeV/u in a region of less than 1 mm2 is briefly reported.

  11. Numerical simulations to model laser-driven coil-capacitor targets for generation of kilo-Tesla magnetic fields

    Science.gov (United States)

    Schillaci, F.; De Marco, M.; Giuffrida, L.; Fujioka, S.; Zhang, Z.; Korn, G.; Margarone, D.

    2018-02-01

    A coil-capacitor target is modeled using FEM simulations and analytical calculations, which allow to explain the time evolution of such complex target during magnetic field production driven by the flow of an extremely high current generated through the interaction with a high power laser. The numerical model includes a detailed study of the magnetic field produced by the coil-capacitor target, both in the static and transient cases, as well as magnetic force and Joule heating. The model is validated by experimental data reported in literature and can be of interest for several applications. As an example, the combination of two synchronized nanosecond lasers with the purpose of producing a plasma responsible of the proton-boron (p+ + 11B → 8.5 MeV + 3α) fusion reaction, and energizing two multi-turn coils with the main purpose of confining such a plasma could enhance the reaction rate. The preliminary conceptual design of a magnetic mirror configuration to be used for confining protons and boron ions up to a few MeV/u in a region of less than 1 mm2 is briefly reported.

  12. Rapid and sensitive detection of canine distemper virus by one-tube reverse transcription-insulated isothermal polymerase chain reaction.

    Science.gov (United States)

    Wilkes, Rebecca P; Tsai, Yun-Long; Lee, Pei-Yu; Lee, Fu-Chun; Chang, Hsiao-Fen Grace; Wang, Hwa-Tang Thomas

    2014-09-09

    Canine distemper virus (CDV) has been associated with outbreaks of canine infectious respiratory disease in shelters and boarding kennel environments. POCKITTM Nucleic Acid Analyzer is a field-deployable device capable of generating automatically interpreted insulated isothermal polymerase chain reaction (iiPCR) results from extracted nucleic acid within one hour. In this study, reverse transcription iiPCR (RT-iiPCR) was developed to facilitate point-of-need diagnosis of CDV infection. Analytical sensitivity (limit of detection 95%) of the established CDV RT-iiPCR was about 11 copies of in vitro transcribed RNA per reaction. CDV RT-iiPCR generated positive signals from CDV, but not Bordetella bronchiseptica, canine parvovirus, canine herpesvirus, canine adenovirus 2, canine influenza virus (subtype H3N8), canine parainfluenza virus, and canine respiratory coronavirus. To evaluate accuracy of the established reaction in canine distemper clinical diagnosis, 110 specimens from dogs, raccoons, and foxes suspected with CDV infection were tested simultaneously by CDV RT-iiPCR and real-time RT-PCR. CDV RT-iiPCR demonstrated excellent sensitivity (100%) and specificity (100%), compared to real-time RT-PCR. The results indicated an excellent correlation between RT-iiPCR and a reference real time RT-PCR method. Working in a lyophilized format, the established method has great potential to be used for point-of-care diagnosis of canine distemper in animals, especially in resource-limited facilities.

  13. Novel heterometallic metal–azido complex synthesized by “one-step” reaction: synthetic strategy and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Yong-Kun [School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Li, Xiu-Ping [Technical center for safety of industrial products of Tianjin entry-exit inspection and quarantine bureau, Tianjin 300201 (China); Zhao, Cui; Wang, Hai-Chao; Xue, Min [School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Zhao, Jiong-Peng, E-mail: horryzhao@yahoo.com [School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Liu, Fu-Chen, E-mail: fuchenliutj@yahoo.com [School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Lanzhou Petrochemical College of Vocational Technology, Lanzhou 730060 (China)

    2013-06-15

    A novel heterometallic complex, [Ni{sub 2}Mn(N{sub 3}){sub 2}(nic){sub 4}·(H{sub 2}O){sub 2}]{sub n} (1) (nic=nicotinate), was obtained by assembling MnCl{sub 2}·4H{sub 2}O, Ni(NO{sub 3}){sub 2}·6H{sub 2}O, NaN{sub 3} and nicotinic acid with a “one step” synthetic strategy—hydrothermal reaction. The 3D structure of the complex can be described as end-on (EO) azido and syn,syn carboxylates mixed bridged by alternate Ni–Mn–Ni trimers linked by the nicotinate. Dominant ferromagnetic interactions were observed between the Ni{sup II} and Mn{sup II} ions in the trimer. - Graphical abstract: A novel heterometallic 3D complex [Ni{sub 2}Mn(N{sub 3}){sub 2}(nic){sub 4}·(H{sub 2}O){sub 2}]{sub n} (1) (nic=nicotinate) was synthesized by hydrothermal reaction. This complex exhibits interesting structural and magnetic properties. - Highlights: • It is difficult to construct simple coordination complexes with azide as “ligands” to obtain heterometallic metal–azido compounds. • A “one-step” method—hydrothermal reaction— was introduced to avoid the disadvantages of azide mentioned above. • The magnetic property is different with the isostructural homometal–azido complex due to the changed metal center.

  14. Are depressive persons capable of describing changes in their reactions without being able to explain them? A proof of a cybernetic hypothesis of depression.

    Science.gov (United States)

    Leibetseder, Max; Kamolz, Thomas

    2004-01-01

    Many studies on the autobiographical memory and the explanation of reasons for success and failure proved that persons suffering from major depression tend to overgeneralize. This study examines the hypothesis that changes of reactions caused by a depressive disorder can be described by the affected persons but not explained. Persons suffering from major depression and persons with posttraumatic stress disorder or disturbance of accommodation with depressive mood (= reactive form of a depressive disorder) were presented with a list of modalities (behaviour, emotional and physical reactions) characteristic for depression. They were asked to identify modalities applicable to them and to describe and explain them. Their responses were analysed using a content analysis and assigned to the categories description and explanation. Persons with a major depression tended to use explanations or evaluations rather than descriptions for their depression-related modalities. Those persons suffering from a reactive form of depressive disorder tended to prefer evaluations. These results support the assumption that states of depression cause general descriptions of depression-relevant behaviour. The specific characteristics that have been perceived confirm the general concepts, which however make the patient prone to the respective selective perceptions. Persons suffering from a reactive form of depressive mood cannot be assumed to have this tendency of self-affirmation. Their depressive state may be maintained by perseverating general pessimistic schemes. It must however be conceded that it was not possible to control the physical comorbidity methodically and to take its effects into consideration, even though only persons without serious illnesses were included in the samples. This study did not verify whether other clinical groups, like patients suffering from anxiety, show the same patterns of explaining and describing their problems. It should furthermore be reviewed how other

  15. Structure sensitive reactions over Co, Fe and mixed metal clusters in zeolites. Annual technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Suib, S.L.

    1992-08-01

    Transient and steady state kinetic studies of structure sensitive reactions of cyclopropane (c-C{sub 3}H{sub 6}) and hydrogen over zeolites is the first area of this studied. Low level impurity Fe{sup 3+} ions in zeolites complicate interpretation of spectroscopic and catalytic studies of these systems. We focused our efforts on selectively substituting Fe{sup 3+} ions in the frameworks of various zeolites to understand their role in catalytic reactions such as with c-C{sub 3}H{sub 6} and H{sub 2}. These studies led to isomorphous substitution of other ions like B{sup 3+} and their use in isomerization of n-butenes to isobutylene. The third area of research involves the synthesis, characterization and catalysis of a new class of molecular sieve manganese oxide tunnel structure materials.

  16. Infrared laser-induced chemical reactions

    International Nuclear Information System (INIS)

    Katayama, Mikio

    1978-01-01

    The experimental means which clearly distinguishes between infrared ray-induced reactions and thermal reactions has been furnished for the first time when an intense monochromatic light source has been obtained by the development of infrared laser. Consequently, infrared laser-induced chemical reactions have started to develop as one field of chemical reaction researches. Researches of laser-induced chemical reactions have become new means for the researches of chemical reactions since they were highlighted as a new promising technique for isotope separation. Specifically, since the success has been reported in 235 U separation using laser in 1974, comparison of this method with conventional separation techniques from the economic point of view has been conducted, and it was estimated by some people that the laser isotope separation is cheaper. This report briefly describes on the excitation of oscillation and reaction rate, and introduces the chemical reactions induced by CW laser and TEA CO 2 laser. Dependence of reaction yield on laser power, measurement of the absorbed quantity of infrared ray and excitation mechanism are explained. Next, isomerizing reactions are reported, and finally, isotope separation is explained. It was found that infrared laser-induced chemical reactions have the selectivity for isotopes. Since it is evident that there are many examples different from thermal and photo-chemical reactions, future collection of the data is expected. (Wakatsuki, Y.)

  17. Magnetic and Engineering Analysis of an Adjustable Strength Permanent Magnet Quadrupole

    CERN Document Server

    Gottschalk, Stephen C

    2005-01-01

    Magnetic and engineering analyses used in the design of an adjustable strength permanent magnet quadrupole will be reported. The quadrupole designed has a pole length of 42cm, aperture diameter 13mm, peak pole tip strength 1.03Tesla and peak integrated gradient * length (GL) of 68.7Tesla. Analyses of magnetic strength, field quality, magnetic centerline, temperature compensation and dynamic eddy currents induced during field adjustments will be presented. Magnet sorting strategies, pole positioning sensitivity, component forces, and other sensitivity analyses will be presented. Engineering analyses of stress, deflection and thermal effects as well as compensation strategies will also be shown.

  18. SENSIT: a cross-section and design sensitivity and uncertainty analysis code

    International Nuclear Information System (INIS)

    Gerstl, S.A.W.

    1980-01-01

    SENSIT computes the sensitivity and uncertainty of a calculated integral response (such as a dose rate) due to input cross sections and their uncertainties. Sensitivity profiles are computed for neutron and gamma-ray reaction cross sections of standard multigroup cross section sets and for secondary energy distributions (SEDs) of multigroup scattering matrices. In the design sensitivity mode, SENSIT computes changes in an integral response due to design changes and gives the appropriate sensitivity coefficients. Cross section uncertainty analyses are performed for three types of input data uncertainties: cross-section covariance matrices for pairs of multigroup reaction cross sections, spectral shape uncertainty parameters for secondary energy distributions (integral SED uncertainties), and covariance matrices for energy-dependent response functions. For all three types of data uncertainties SENSIT computes the resulting variance and estimated standard deviation in an integral response of interest, on the basis of generalized perturbation theory. SENSIT attempts to be more comprehensive than earlier sensitivity analysis codes, such as SWANLAKE

  19. Magnetic design consideration of a Magnetic Lead Screw with Halbach Array

    DEFF Research Database (Denmark)

    Holm, Rasmus Koldborg; Berg, Nick Ilsø; Rasmussen, Peter Omand

    This paper presents the novel design of a Magnetic Lead Screw (MLS) with magnetic thread of Halbach Arrays. The MLS where designed and build, tests indicated a stall force which where 12 % lower than calculated in 3D FE. This is explained by demagnetization of the magnet during stall, the behavio...

  20. Muscle magnetic resonance imaging sensitivity does not decrease in chronic, mild, or proximal lower limb neuropathies.

    Science.gov (United States)

    Deroide, Nicolas; Bousson, Valérie; Daguet, Edouard; Dumurgier, Julien; Tin, Sophie Ng Wing; Hannouche, Didier; Richette, Pascal; Beaudreuil, Johann; Lioté, Frédéric; Lévy, Bernard; Vicaut, Eric; Laredo, Jean Denis; Kubis, Nathalie

    2012-05-01

    Muscle magnetic resonance imaging (MRI) is an innovative tool for exploring focal neuropathies. However, its usefulness in mild, proximal, or chronic lesions, when electromyography (EMG), the current "gold standard" sensitivity is inadequate, has yet to be studied. Clinical, MRI, and EMG examinations were performed in 113 muscles of 17 consecutive patients with clinically diagnosed lower limb focal neuropathies. The sensitivity and specificity of MRI and EMG were evaluated in relation to disease duration, severity, and anatomical location. Muscle MRI was highly sensitive for the detection of denervated muscle, and, unlike EMG, its sensitivity did not decrease regardless of the anatomical location, duration, or severity of the neuropathy. Five MRI false positives were noted, including three in the thigh muscles. Muscle MRI is an alternative tool to EMG in proximal, mild, or chronic clinical diagnoses of lower limb focal neuropathies. However, it also seems prone to false-positive results, particularly in proximal muscles. Copyright © 2012 Wiley Periodicals, Inc.

  1. Hyperfine interactions in ferromagnetic materials and magnetic properties of 1fsub(7/2) nuclei

    International Nuclear Information System (INIS)

    Bozek, E.

    1976-01-01

    Hyperfine interactions of light nuclei recoil-implanted into iron, nickel and cobalt were studied using the perturbed integral angular distribution IMPAD. Isomeric states of lifetimes within the nanosecond range were excited in the following reactions: 28 Si 14 N, xn, yp 37 Ar, 39 K, 40 K; 27 Al 16 O, xn, yp 41 K, 41 Ca. In all cases except implantation of potassium isotopes into nickel observed shifts of angular distribution were found much smaller than the ones calculated using the known values of g factors, livetimes and strengths of the hyperfine fields. This effect can be explained under the assumption that only a fraction of nuclei feel the full magnetic field. Different fractions obtained for 40 K and 41 K suggest a migration process on a ns time scale. The magnetic moments of isomeric nuclear states excited in reaction 27 Al 14 N, p 36 Cl, 24 Mg 19 F, 2pn 40 K and 48 Ca, 2n 50 Ti were measured using the perturbed integral angular distribution technique - IPAD in an external magnetic field. The g factors for the investigated states were interpreted on the base of the shell model, assuming the effective magnetic moments associated with shell model orbitals dsub(3/2) and fsub(7/2). (author)

  2. Nuclear Reaction Data File for Astrophysics (NRDF/A) in Hokkaido University Nuclear Reaction Data Center

    International Nuclear Information System (INIS)

    Kato, Kiyoshi; Kimura, Masaaki; Furutachi, Naoya; Makinaga, Ayano; Togashi, Tomoaki; Otuka, Naohiko

    2010-01-01

    The activities of the Japan Nuclear Reaction Data Centre is explained. The main task of the centre is data compilation of Japanese nuclear reaction data in collaboration of the International Network of Nuclear Reaction Data Centres. As one of recent activities, preparation of a new database (NRDF/A) and evaluation of astronuclear reaction data are reported. Collaboration in the nuclear data activities among Asian countries is proposed.

  3. Highly sensitive "signal-on" electrochemiluminescent biosensor for the detection of DNA based on dual quenching and strand displacement reaction.

    Science.gov (United States)

    Lou, Jing; Wang, Zhaoyin; Wang, Xiao; Bao, Jianchun; Tu, Wenwen; Dai, Zhihui

    2015-10-07

    A "signal-on" electrochemiluminescent DNA biosensing platform was proposed based on the dual quenching and strand displacement reaction. This novel "signal-on" detection strategy revealed its sensitivity in achieving a detection limit of 2.4 aM and its selectivity in distinguishing single nucleotide polymorphism of target DNA.

  4. Magnetization of Paraffin-Based Magnetic Nanocolloids

    Science.gov (United States)

    Dikanskii, Yu. I.; Ispiryan, A. G.; Kunikin, S. A.; Radionov, A. V.

    2018-01-01

    Using paraffin-based magnetic nanocolloids as an example, the reasons for maxima in the temperature dependence of the magnetic susceptibility of magnetic colloids have been discussed. The behavior of these dependences in a wide temperature interval has been analyzed for colloids in solid and liquid states. It has been concluded that the maximum observed at the melting point of paraffin can be attributed to freezing Brownian degrees of freedom in magnetite coarse particles, the magnetic moment of which is intimately related to the solid matrix. The second main maximum, which arises in the solid state, is explained by the superparamagnetic-magnetically hard transition of most fine particles at lower temperatures. It has been noted that the flatness of this maximum results from the polydispersity of the magnetic nanoparticle ensemble.

  5. Department of Nuclear Reaction - Overview

    International Nuclear Information System (INIS)

    Budzanowski, A.

    2000-01-01

    Full text: This year 1999 can be considered as very successful. Not only that we have published 33 papers in journals listed by the Philadelphia Institute of Science but because our hard work allowed us to obtain new and exciting results. A group of theoretical papers concerned with application of correlation among random matrices elements developed for statistical aspects of nuclear coupling into continuum to study of the collective effects in brain activity and stock market dynamics. These papers arose quite an interest and got several citations. Studies of the nonpartonic components in the nucleon structure function led to better understanding of the higher-twist effects. It was shown that inclusion of the terms of the order of 1/Q 4 improves fits to the experimental data. A review paper summarizing results on the role of the leading baryon in high energy reactions appeared in Progress on Nuclear and Particle Physics. Studies on multistep transfer reactions of light heavy ions in collaboration with the Institute of Nuclear Physics of the Ukrainian Academy of Sciences in Kiev have explained angular distributions of many reactions using the coupled channel theory. We have shown that it is possible to determine energy dependence of the optical model potential for such unstable nuclei like 8 Be. Further studies of mechanism of near threshold light meson production in collaboration with Juelich and Jagiellonian University were performed. Within COSY 10 and COSY 11 collaborations new data on the isospin symmetry breaking in pionic reactions and strange meson accompanied by hyperons emission were obtained. Together with colleagues from the Flerov Nuclear Reaction Laboratory we have started experiments with radioactive beams. Using magnetic separator COMBAS velocity distributions of isotopes with 2 ≤Z≤11 in reactions induced by 16 O on 9 Be were obtained. At the high resolution radioactive beam channel ACCULINA reactions induced by 6 He and 8 He nuclei were studied

  6. Magnetic nanocomposite sensor

    KAUST Repository

    Alfadhel, Ahmed

    2016-05-06

    A magnetic nanocomposite device is described herein for a wide range of sensing applications. The device utilizes the permanent magnetic behavior of the nanowires to allow operation without the application of an additional magnetic field to magnetize the nanowires, which simplifies miniaturization and integration into microsystems. In5 addition, the nanocomposite benefits from the high elasticity and easy patterning of the polymer-based material, leading to a corrosion-resistant, flexible material that can be used to realize extreme sensitivity. In combination with magnetic sensor elements patterned underneath the nanocomposite, the nanocomposite device realizes highly sensitive and power efficient flexible artificial cilia sensors for flow measurement or tactile sensing.

  7. Impedance spectroscopy on pH-sensors with lithium lanthanum titanate sensitive material

    International Nuclear Information System (INIS)

    Bohnke, Cl.; Fourquet, J.-L.

    2003-01-01

    The ceramic Li 3x La 2/3-x , 1/3-2x TiO 3 is used, in an all-solid-state configuration, as pH-sensor in aqueous buffer solution. This ceramic displays a pH sensitivity comparable to the one obtained with a commercial glass electrode and does not show any sensitivity to the redox potential of the solution. This is one of the remarkable properties of this ceramic pH-sensor. It is shown in this paper that the reproducibility and the behaviour of the pH-response depend on the morphology of the grain boundaries particularly on the size of the grains. A so-called 'good' pH-response is obtained with a ceramic showing big and homogeneous grains. Complex impedance spectroscopy reveals that such ceramic has a high grain boundary resistance. Furthermore, this electrochemical technique allows us to determine that the interface reaction involved in the pH detection has a time constant of the order of the second. Several assumptions such as ion exchange or acid-base reaction are proposed to explain the sensitivity of the ceramic material to the pH of the solution

  8. Structural, magnetic and dielectric properties of Y doped BiFeO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Min [School of Materials Science and Engineering, Shanghai University, Shanghai, 200072 (China); Kumar, N. Pavan [Departmant of Physics, Osmania University, Hyderabad, 500 007 (India); Department of Physics, National Institute of Technology, Warangal, 506002 (India); Sagar, E. [Departmant of Physics, Osmania University, Hyderabad, 500 007 (India); Jian, Zhu; Yemin, Hu [School of Materials Science and Engineering, Shanghai University, Shanghai, 200072 (China); Reddy, P. Venugopal, E-mail: paduruvenugopalreddy@gmail.com [Departmant of Physics, Osmania University, Hyderabad, 500 007 (India); Vidya Jyothi Institute of Technology, Aziz Nagar Gate, C.B. Post, Hyderabad, 500075 (India)

    2016-04-15

    With a view to understand the influence of doping Bismuth ferrite with Yttrium on structural, magnetic and dielectric behavior, a series of samples were prepared by the solid state reaction technique. After characterizing the samples with XRD and SEM studies, magnetic and dielectric measurements were carried out. The impurity phase of Bismuth ferrite is found to disappear with increasing Y doping concentration and finally the sample with x = 0.2 is found to be free from secondary phases. The dielectric constant is also found to exhibit two transitions and efforts were made to explain the observed behavior. - Highlights: • The doping of Y helped in reducing the impurity phase of BiFeO{sub 3}. • All the Y doped samples are found to exhibit peaks in magnetization. • Y doped BFO might be considered for future device applications.

  9. Microstructural evaluation and magnetic Ni-Zn ferrite sintered by microwave energy

    International Nuclear Information System (INIS)

    Diniz, Veronica Cristhina S.; Vieira, Debora A.; Costa, Ana Cristina F.M.; Kiminami, R.H.G.A.; Cornejo, Daniel Reinaldo

    2011-01-01

    The present Ni-Zn ferrite magnetic properties sensitive to microstructure and obtain a ferrite with a uniform microstructure is the biggest challenge in the advancement of new technologies. This study proposes to evaluate the microstructure and magnetic properties of Ni-Zn ferrite sintered by microwave energy. The samples were previously synthesized by combustion reaction using urea and glycine, with 1200 deg C/2h sintered at a heating rate of 5 deg C/min, and characterized by density, XRD, SEM and magnetic measurements. The results show that the sample synthesized with glycine showed the formation of ferrite phase and traces of secondary phase hematite, grains with undefined format, and a high porosity and inter intragranular. The sample synthesized with urea gave only the ferrite phase, with hexagonal grains, and low intergranular porosity. The sample synthesized with urea showed better magnetic characteristics when compared with the samples synthesized with glycine. (author)

  10. A sensitive kinetic spectrophotometric determination of traces of tungsten in solution based on its inhibitory effect on the decolorization reaction of potassium permanganate

    Directory of Open Access Journals (Sweden)

    Petković Branka

    2016-01-01

    Full Text Available The present work describes a rapid and sensitive method for the determination of ultra micro amounts of tungsten (VI based on its inhibitory effect on the oxidation of 4-hidroxycoumarine by potassium permanganate in the presence of hydrochloric acid. The sensitivity of the method is 20 ng/cm3. The probable relative error is -4.8-13 % for the W(VI concentration range 250 to 20 ng/cm3, respectively. Kinetic equations for the investigated process which determine the order of the reactions regarding to each reaction parameter under certain experimental conditions were proposed, and they allowed quantification of the unknown concentrations W(VI in solution. The detection and quantification limit of the method are 4.5 and 15.1 ng/cm3. The effects of certain foreign ions upon the reaction rate were determined for the assessing the selectivity of the method.

  11. Nuclear reactions

    International Nuclear Information System (INIS)

    Corner, J.; Richardson, K.; Fenton, N.

    1990-01-01

    Nuclear reactions' marks a new development in the study of television as an agency of public policy debate. During the Eighties, nuclear energy became a major international issue. The disasters at Three-mile Island and Chernobyl created a global anxiety about its risks and a new sensitivity to it among politicians and journalists. This book is a case-study into documentary depictions of nuclear energy in television and video programmes and into the interpretations and responses of viewers drawn from many different occupational groupings. How are the complex and specialist arguments about benefit, risk and proof conveyed through the different conventions of commentary, interview and film sequence? What symbolic associations does the visual language of television bring to portrayals of the issue? And how do viewers make sense of various and conflicting accounts, connecting what they see and hear on the screen with their pre-existing knowledge, experience and 'civic' expectations. The authors examine some of the contrasting forms and themes which have been used by programme makers to explain and persuade, and then give a sustained analysis of the nature and sources of viewers' own accounts. 'Nuclear Reactions' inquires into the public meanings surrounding energy and the environment, spelling out in its conclusion some of the implications for future media treatments of this issue. It is also a key contribution to the international literature on 'television knowledge' and the processes of active viewing. (author)

  12. Comparison of sensitivity of magnetic resonance imaging and evoked potentials in the detection of brainstem involvement in multiple sclerosis

    International Nuclear Information System (INIS)

    Comi, G.; Martinelli, V.; Medaglini, S.; Locatelli, T.; Magnani, G.; Poggi, A.; Triulzi, F.

    1988-01-01

    A comparison was made of the sensitivity of magnetic resonance imaging and the combined use of Brainstem Auditory Evoked Potential and Median Somatosensory Evoked Potential in the detection of brainstem dysfunction in 54 multiple sclerosis patients. 10 refs.; 2 tabs

  13. Sensitivity analysis explains quasi-one-dimensional current transport in two-dimensional materials

    DEFF Research Database (Denmark)

    Boll, Mads; Lotz, Mikkel Rønne; Hansen, Ole

    2014-01-01

    We demonstrate that the quasi-one-dimensional (1D) current transport, experimentally observed in graphene as measured by a collinear four-point probe in two electrode configurations A and B, can be interpreted using the sensitivity functions of the two electrode configurations (configurations...... A and B represents different pairs of electrodes chosen for current sources and potential measurements). The measured sheet resistance in a four-point probe measurement is averaged over an area determined by the sensitivity function. For a two-dimensional conductor, the sensitivity functions for electrode...... configurations A and B are different. But when the current is forced to flow through a percolation network, e.g., graphene with high density of extended defects, the two sensitivity functions become identical. This is equivalent to a four-point measurement on a line resistor, hence quasi-1D transport...

  14. Broad-band linear polarization and magnetic intensification in rotating magnetic stars

    International Nuclear Information System (INIS)

    Degl'Innocenti, M.L.; Calamai, G.; Degl'Innocenti, E.L.; Patriarchi, P.

    1981-01-01

    Magnetic intensification is proposed as a mechanism to explain the general features of the variable broad-band linear polarization emerging from rotating magnetic stars. This mechanism is studied in detail, and some efforts are made to investigate the wide variety of polarization diagrams that can result from it. Theoretical results are compared with direct observations of the variable magnetic star 53 Cam to determine its geometric and magnetic configuration

  15. Magnetic field effects on exciplex-forming systems: the effect on the locally excited fluorophore and its dependence on free energy.

    Science.gov (United States)

    Kattnig, Daniel R; Rosspeintner, Arnulf; Grampp, Günter

    2011-02-28

    This study addresses magnetic field effects in exciplex forming donor-acceptor systems. For moderately exergonic systems, the exciplex and the locally excited fluorophore emission are found to be magneto-sensitive. A previously introduced model attributing this finding to excited state reversibility is confirmed. Systems characterised by a free energy of charge separation up to approximately -0.35 eV are found to exhibit a magnetic field effect on the fluorophore. A simple three-state model of the exciplex is introduced, which uses the reaction distance and the asymmetric electron transfer reaction coordinate as pertinent variables. Comparing the experimental emission band shapes with those predicted by the model, a semi-quantitative picture of the formation of the magnetic field effect is developed based on energy hypersurfaces. The model can also be applied to estimate the indirect contribution of the exchange interaction, even if the perturbative approach fails. The energetic parameters that are essential for the formation of large magnetic field effects on the exciplex are discussed.

  16. Magnetic Thermometer: Thermal effect on the Agglomeration of Magnetic Nanoparticles by Magnetic field

    Science.gov (United States)

    Jin, Daeseong; Kim, Hackjin

    2018-03-01

    We have investigated the agglomeration of magnetite nanoparticles in the aqueous solution under magnetic field by measuring temporal change of magnetic weight. The magnetic weight corresponds to the force due to the magnetization of magnetic materials. Superparamagnetic magnetite nanoparticles are synthesized and used in this work. When the aqueous solution of magnetite nanoparticle is placed under magnetic field, the magnetic weight of the sample jumps instantaneously by Neel and Brown mechanisms and thereafter increases steadily following a stretched exponential function as the nanoparticles agglomerate, which results from the distribution of energy barriers involved in the dynamics. Thermal motions of nanoparticles in the agglomerate perturb the ordered structure of the agglomerate to reduce the magnetic weight. Fluctuation of the structural order of the agglomerate by temperature change is much faster than the formation of agglomerate and explained well with the Boltzmann distribution, which suggests that the magnetic weight of the agglomerate works as a magnetic thermometer.

  17. Design and experimental validation of Unilateral Linear Halbach magnet arrays for single-sided magnetic resonance.

    Science.gov (United States)

    Bashyam, Ashvin; Li, Matthew; Cima, Michael J

    2018-07-01

    Single-sided NMR has the potential for broad utility and has found applications in healthcare, materials analysis, food quality assurance, and the oil and gas industry. These sensors require a remote, strong, uniform magnetic field to perform high sensitivity measurements. We demonstrate a new permanent magnet geometry, the Unilateral Linear Halbach, that combines design principles from "sweet-spot" and linear Halbach magnets to achieve this goal through more efficient use of magnetic flux. We perform sensitivity analysis using numerical simulations to produce a framework for Unilateral Linear Halbach design and assess tradeoffs between design parameters. Additionally, the use of hundreds of small, discrete magnets within the assembly allows for a tunable design, improved robustness to variability in magnetization strength, and increased safety during construction. Experimental validation using a prototype magnet shows close agreement with the simulated magnetic field. The Unilateral Linear Halbach magnet increases the sensitivity, portability, and versatility of single-sided NMR. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Dual Recognition Strategy for Specific and Sensitive Detection of Bacteria Using Aptamer-Coated Magnetic Beads and Antibiotic-Capped Gold Nanoclusters.

    Science.gov (United States)

    Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun

    2016-01-05

    Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.

  19. Reliability and sensitivity to change of the OMERACT rheumatoid arthritis magnetic resonance imaging score in a multireader, longitudinal setting

    DEFF Research Database (Denmark)

    Haavardsholm, ea; Østergaard, Mikkel; Kvan, NP

    2005-01-01

    OBJECTIVE: To assess the intra- and interreader reliability and the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) system on digital images of the wrist joints of patients with early or establi...

  20. Anomalous magnetic viscosity in α-Fe(Co)/(Nd,Pr)2Fe14B exchange-spring magnet

    International Nuclear Information System (INIS)

    Hai, Nguyen Hoang; Chau, Nguyen; Ngo, Duc-The; Gam, Duong Thi Hong

    2011-01-01

    This article presents an anomalous magnetic viscosity in α-Fe(Co)/(Nd,Pr) 2 Fe 14 B exchange-spring magnet. A similar effect has been observed in non-interacting or weakly interacting systems but not in a strong interacting magnetic systems. We reported a new procedure to measure magnetic relaxation under various magnetic fields. Changing the applied magnetic field by different field protocols during the reversal process, we found that a memory effect of the magnetization appeared if the field change is large enough. The mechanism of the phenomenon can be explained in the model of conventional magnetic reversal in strong ferromagnetic systems with an energy barrier distribution. The study of such magnetic relaxations can provide some information related to the energy barrier distribution function. - Highlights: → The memory effect was observed in a strong magnetically interacting system. → The memory effect on hard magnets can be explained by conventional reversal mechanism. → And it provides some information of the energy barrier for the reversal of magnetic moments.

  1. Dual responsive PNIPAM–chitosan targeted magnetic nanopolymers for targeted drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Yadavalli, Tejabhiram, E-mail: tejabhiram@gmail.com [Nanotechnology Research Centre, SRM University, Chennai 603203 (India); Ramasamy, Shivaraman [Nanotechnology Research Centre, SRM University, Chennai 603203 (India); School of Physics, The University of Western Australia, 35 Stirling Hwy, Crawley, WA 6009 (Australia); Chandrasekaran, Gopalakrishnan; Michael, Isaac; Therese, Helen Annal [Nanotechnology Research Centre, SRM University, Chennai 603203 (India); Chennakesavulu, Ramasamy [Department of Pharmacy practice, SRM College of Pharmacy, Chennai 603203 (India)

    2015-04-15

    A dual stimuli sensitive magnetic hyperthermia based drug delivery system has been developed for targeted cancer treatment. Thermosensitive amine terminated poly-N-isopropylacrylamide complexed with pH sensitive chitosan nanoparticles was prepared as the drug carrier. Folic acid and fluorescein were tagged to the nanopolymer complex via N-hydroxysuccinimide and ethyl-3-(3-dimethylaminopropyl)carbodiimide reaction to form a fluorescent and cancer targeting magnetic carrier system. The formation of the polymer complex was confirmed using infrared spectroscopy. Gadolinium doped nickel ferrite nanoparticles prepared by a hydrothermal method were encapsulated in the polymer complex to form a magnetic drug carrier system. The proton relaxation studies on the magnetic carrier system revealed a 200% increase in the T1 proton relaxation rate. These magnetic carriers were loaded with curcumin using solvent evaporation method with a drug loading efficiency of 86%. Drug loaded nanoparticles were tested for their targeting and anticancer properties on four cancer cell lines with the help of MTT assay. The results indicated apoptosis of cancer cell lines within 3 h of incubation. - Highlights: • The use of gadolinium doped nickel ferrite with the suggested doping level. • The use of PNIPMA–chitosan polymer with folic acid and fluorescein as a drug carrier complex. • Magnetic hyperthermia studies of gadolinium doped nickel ferrites are being reported for the first time. • Proton relaxivity studies which indicate the MRI contrasting properties on the reported system are new. • Use of curcumin, a hydrophobic Indian spice as a cancer killing agent inside the reported magnetic polymer complex.

  2. Near-infrared responsive PbS-sensitized photovoltaic photodetectors fabricated by the spin-assisted successive ionic layer adsorption and reaction method

    International Nuclear Information System (INIS)

    Im, Sang Hyuk; Kim, Hi-jung; Seok, Sang Il

    2011-01-01

    A PbS-sensitized photovoltaic photodetector responsive to near-infrared (NIR) light was fabricated by depositing monolayered PbS nanoparticles on a mesoporous TiO 2 (mp-TiO 2 ) film via the spin-assisted successive ionic layer adsorption and reaction (SILAR) method. By adjusting the size and morphology of the PbS nanoparticles through repeated spin-assisted SILAR cycles, the PbS-sensitized photovoltaic photodetector achieved an external quantum efficiency of 9.3% at 1140 nm wavelength and could process signals up to 1 kHz.

  3. Applications of Reaction Rate

    Science.gov (United States)

    Cunningham, Kevin

    2007-01-01

    This article presents an assignment in which students are to research and report on a chemical reaction whose increased or decreased rate is of practical importance. Specifically, students are asked to represent the reaction they have chosen with an acceptable chemical equation, identify a factor that influences its rate and explain how and why it…

  4. Sensitive and selective determination of fluvoxamine maleate using a sensitive chemiluminescence system based on the alkaline permanganate-Rhodamine B-gold nanoparticles reaction.

    Science.gov (United States)

    Hassanzadeh, Javad; Amjadi, Mohammad

    2015-06-01

    A high-yield chemiluminescence (CL) system based on the alkaline permanganate-Rhodamine B reaction was developed for the sensitive determination of fluvoxamine maleate (Flu). Rhodamine B is oxidized by alkaline KMnO4 and a weak CL emission is produced. It was demonstrated that gold nanoparticles greatly enhance this CL emission due to their interaction with Rhodamine B molecules. It is also observed that sodium dodecyl sulfate, an anionic surfactant, can strongly increase this enhancement. In addition, it was demonstrated that a notable decrease in the CL intensity is observed in the presence of Flu. This may be related to Flu oxidation with KMnO4 . There is a linear relationship between the decrease in CL intensity and the Flu concentration over a range of 2-300 µg/L. A new simple, rapid and sensitive CL method was developed for the determination of Flu with a detection limit (3s) of 1.35 µg/L. The proposed method was used for the determination of Flu in pharmaceutical and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Magnetization of the oceanic crust: TRM or CRM?

    Science.gov (United States)

    Raymond, C. A.; Labrecque, J. L.

    1987-01-01

    A model was proposed in which chemical remanent magnetization (CRM) acquired within the first 20 Ma of crustal evolution may account for 80% of the bulk natural remanent magnetization (NRM) of older basalts. The CRM of the crust is acquired as the original thermoremanent magnetization (TRM) is lost through low temperature alteration. The CRM intensity and direction are controlled by the post-emplacement polarity history. This model explains several independent observations concerning the magnetization of the oceanic crust. The model accounts for amplitude and skewness discrepancies observed in both the intermediate wavelength satellite field and the short wavelength sea surface magnetic anomaly pattern. It also explains the decay of magnetization away from the spreading axis, and the enhanced magnetization of the Cretaceous Quiet Zones while predicting other systematic variations with age in the bulk magnetization of the oceanic crust. The model also explains discrepancies in the anomaly skewness parameter observed for anomalies of Cretaceous age. Further studies indicate varying rates of TRM decay in very young crust which depicts the advance of low temperature alteration through the magnetized layer.

  6. Force detection of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rugar, D.; Zueger, O.; Hoen, S.; Yannoni, C.S.; Vieth, H.M.; Kendrick, R.D.

    1994-01-01

    Micromechanical sensing of magnetic force was used to detect nuclear magnetic resonance with exceptional sensitivity and spatial resolution. With a 900 angstrom thick silicon nitride cantilever capable of detecting subfemtonewton forces, a single shot sensitivity of 1.6 x 10 13 protons was achieved for an ammonium nitrate sample mounted on the cantilever. A nearby millimeter-size iron particle produced a 600 tesla per meter magnetic field gradient, resulting in a spatial resolution of 2.6 micrometers in one dimension. These results suggest that magnetic force sensing is a viable approach for enhancing the sensitivity and spatial resolution of nuclear magnetic resonance microimaging

  7. Combination of in situ metathesis reaction with a novel "magnetic effervescent tablet-assisted ionic liquid dispersive microextraction" for the determination of endogenous steroids in human fluids.

    Science.gov (United States)

    Wu, Jia; Xu, Zilin; Pan, Yixuan; Shi, Yi; Bao, Xiujie; Li, Jun; Tong, Yu; Tang, Han; Ma, Shuyan; Wang, Xuedong; Lyu, Jianxin

    2018-05-01

    Herein, a novel magnetic effervescence tablet-assisted microextraction coupled to in situ metathesis reaction of ionic liquid (IS-META-ILDM) is presented for the determination of four endogenous steroids in human urine, pregnant women's blood, and fetal umbilical cord blood. The magnetic effervescent tablets, which were composed of Fe 3 O 4 nanoparticles, sodium carbonate (alkaline source), and tartaric acid (acidic source), were used to disperse the extractant and for convenient magnetic separation. After the effervescent reaction, in situ reaction between NH 4 PF 6 and [C 6 MIM]BF 4 was adopted to change hydrophilic ionic liquid to hydrophobic liquid, which could be separated from the aqueous phase. The newly developed method has three obvious advantages: (1) combination of effervescent dispersion and magnetic nanoparticles' retrieval is cost-effective and the dispersion and collection of the extractant can be completed almost simultaneously; (2) as compared to temperature-controlled ionic liquid dispersive microextraction and cold-induced solidified microextraction, this method avoids a heating and cooling process which significantly reduces the extraction time and energy cost; and (3) the combination of adsorption by magnetic nanoparticles with extraction by in situ metathesis reaction easily produces high recoveries for target analytes. The optimized composition of effervescent tablet and experimental parameters are as follows: 0.64 g mixture of sodium carbonate and tartaric acid, 7 mg of Fe 3 O 4 (20 nm) as magnetic sorbents, 40 μL of [C 6 MIM]BF 4 as the extraction solvent, 0.15 g NH 4 PF 6 , and 300 μL of elution solvent. Under the optimized conditions, the newly developed method provided high extraction recoveries (90.0-118.5%) and low LODs (0.14-0.17 μg L -1 ) in urine and blood samples. In total, this IS-META-ILDM method provided high extraction efficiency, fast and convenient separation, and underutilization of any organic solvent, and thus

  8. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  9. Possibility to explain the temperature distribution in sunspots by an anisotropic heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Eschrich, K O; Krause, F [Akademie der Wissenschaften der DDR, Potsdam. Zentralinstitut fuer Astrophysik

    1977-01-01

    Numerical solutions of a heat conduction problem in an anisotropic medium are used for a discussion of the possibility to explain the temperature distribution in sunspots and their environment. The anisotropy is assumed being due to the strong magnetic field in sunspots and the region below. This magnetic field forces the convection to take an anisotropic structure (two-dimensional turbulence) and thus the region gets anisotropic conduction properties, on the average. The discussion shows that the observed temperature profiles can be explained in the case the depth of the region of anisotropy is about as large as the diameter of the spot or larger.

  10. Near-infrared responsive PbS-sensitized photovoltaic photodetectors fabricated by the spin-assisted successive ionic layer adsorption and reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Im, Sang Hyuk; Kim, Hi-jung; Seok, Sang Il, E-mail: seoksi@krict.re.kr [KRICT-EPFL Global Research Laboratory, Advanced Materials Division, Korea Research Institute of Chemical Technology, 19 Sinseongno, Yuseong, Daejeon 305-600 (Korea, Republic of)

    2011-09-30

    A PbS-sensitized photovoltaic photodetector responsive to near-infrared (NIR) light was fabricated by depositing monolayered PbS nanoparticles on a mesoporous TiO{sub 2} (mp-TiO{sub 2}) film via the spin-assisted successive ionic layer adsorption and reaction (SILAR) method. By adjusting the size and morphology of the PbS nanoparticles through repeated spin-assisted SILAR cycles, the PbS-sensitized photovoltaic photodetector achieved an external quantum efficiency of 9.3% at 1140 nm wavelength and could process signals up to 1 kHz.

  11. Angular dependence of magnetization reversal in epitaxial chromium telluride thin films with perpendicular magnetic anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Pramanik, Tanmoy, E-mail: pramanik.tanmoy@utexas.edu; Roy, Anupam, E-mail: anupam@austin.utexas.edu; Dey, Rik, E-mail: rikdey@utexas.edu; Rai, Amritesh; Guchhait, Samaresh; Movva, Hema C.P.; Hsieh, Cheng-Chih; Banerjee, Sanjay K.

    2017-09-01

    Highlights: • Perpendicular magnetic anisotropy in epitaxial Cr{sub 2}Te{sub 3} has been investigated. • Presence of a relatively strong second order anisotropy contribution is observed. • Magnetization reversal is explained quantitatively using a 1D defect model. • Relative roles of nucleation and pinning in magnetization reversal are discussed. • Domain structures and switching process are visualized by micromagnetic simulation. - Abstract: We investigate magnetic anisotropy and magnetization reversal mechanism in chromium telluride thin films grown by molecular beam epitaxy. We report existence of strong perpendicular magnetic anisotropy in these thin films, along with a relatively strong second order anisotropy contribution. The angular variation of the switching field observed from the magnetoresistance measurement is explained quantitatively using a one-dimensional defect model. The model reveals the relative roles of nucleation and pinning in the magnetization reversal, depending on the applied field orientation. Micromagnetic simulations are performed to visualize the domain structure and switching process.

  12. Hybridization chain reaction amplification for highly sensitive fluorescence detection of DNA with dextran coated microarrays.

    Science.gov (United States)

    Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua

    2016-07-15

    Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Reaction path simulations in multicomponent materials

    International Nuclear Information System (INIS)

    Seifert, H.J.

    1999-01-01

    The CALPHAD (calculation of phase diagrams) method is used in combination with selected experimental investigations to derive reaction paths in multicomponent systems. The method is illustrated by applying computerized thermodynamic databases and suitable software to explain quantitatively the thermal degradation of precursor-derived Si-C-N ceramics and the nitridation of titanium carbide. Reaction sequences in the Si 3 N 4 -SiC-TiC x N l-x -C-N system are illustrated by graphical representation of compatibility regions and indicated reaction paths. From these results the experimentally known microstructure development of TiC reinforced Si 3 N 4 ceramics is explained and quantitative information is provided to optimize the microstructure of such materials. The concept of reaction paths for the understanding of rapid solidification processes is shown by the example of AZ type Mg casting alloys. (orig.)

  14. Low-temperature magnetic modification of sensitive biological materials

    Czech Academy of Sciences Publication Activity Database

    Pospišková, K.; Šafařík, Ivo

    2015-01-01

    Roč. 142, mar (2015), s. 184-188 ISSN 0167-577X R&D Projects: GA MŠk(CZ) LD13021 Institutional support: RVO:67179843 Keywords : magnetic iron oxides particles * microwave-assisted synthesis * low-temperature magnetic modification * immobilized enzymes Subject RIV: BO - Biophysics Impact factor: 2.437, year: 2015

  15. Magnetic monopole searches with the MoEDAL experiment at the LHC

    CERN Document Server

    Pinfold, J; Lacarrère, D; Mermod, P; Katre, A

    2014-01-01

    The magnetic monopole appears in theories of spontaneous ga uge symmetry breaking and its existence would explain the quantisation of electric charg e. MoEDAL is the latest approved LHC experiment, designed to search directly for monopoles. It h as now taken data for the first time. The MoEDAL detectors are based on two complementary techniq ues: nuclear-track detectors are sensitive to the high-ionisation signature expected fr om a monopole, and the new magnetic monopole trapper (MMT) relies on the stopping and trapping o f monopoles inside an aluminium array which is then analysed with a superconducting magneto meter. Preliminary results obtained with a subset of the MoEDAL MMT test array deployed in 2012 are presented, where monopoles with charge above the fundamental unit magnetic charge or ma ss above 1.5 TeV are probed for the first time at the LHC

  16. Deterministic 3D transport, sensitivity and uncertainty analysis of TPR and reaction rate measurements in HCPB Breeder Blanket mock-up benchmark

    International Nuclear Information System (INIS)

    Kodeli, I.

    2006-01-01

    The Helium-Cooled Pebble Bed (HCPB) Breeder Blanket mock-up benchmark experiment was analysed using the deterministic transport, sensitivity and uncertainty code system in order to determine the Tritium Production Rate (TPR) in the ceramic breeder and the neutron reaction rates in beryllium, both nominal values and the corresponding uncertainties. The experiment, performed in 2005 to validate the HCPB concept, consists of a metallic beryllium set-up with two double layers of breeder material (Li 2 CO 3 powder). The reaction rate measurements include the Li 2 CO 3 pellets for the tritium breeding monitoring and activation foils, inserted at several axial and lateral locations in the block. In addition to the well established and validated procedure based on the 2-dimensional (2D) code DORT, a new approach for the 3D modelling was validated based on the TORT/GRTUNCL3D transport codes. The SUSD3D code, also in 3D geometry, was used for the cross-section sensitivity and uncertainty calculations. These studies are useful for the interpretation of the experimental measurements, in particular to assess the uncertainties linked to the basic nuclear data. The TPR, the neutron activation rates and the associated uncertainties were determined using the EFF-3.0 9 Be nuclear cross section and covariance data, and compared with those from other evaluations, like FENDL-2.1. Sensitivity profiles and nuclear data uncertainties of the TPR and detector reaction rates with respect to the cross-sections of 9 Be, 6 Li, 7 Li, O and C were determined at different positions in the experimental block. (author)

  17. NOX4-dependent neuronal autotoxicity and BBB breakdown explain the superior sensitivity of the brain to ischemic damage.

    Science.gov (United States)

    Casas, Ana I; Geuss, Eva; Kleikers, Pamela W M; Mencl, Stine; Herrmann, Alexander M; Buendia, Izaskun; Egea, Javier; Meuth, Sven G; Lopez, Manuela G; Kleinschnitz, Christoph; Schmidt, Harald H H W

    2017-11-14

    Ischemic injury represents the most frequent cause of death and disability, and it remains unclear why, of all body organs, the brain is most sensitive to hypoxia. In many tissues, type 4 NADPH oxidase is induced upon ischemia or hypoxia, converting oxygen to reactive oxygen species. Here, we show in mouse models of ischemia in the heart, brain, and hindlimb that only in the brain does NADPH oxidase 4 (NOX4) lead to ischemic damage. We explain this distinct cellular distribution pattern through cell-specific knockouts. Endothelial NOX4 breaks down the BBB, while neuronal NOX4 leads to neuronal autotoxicity. Vascular smooth muscle NOX4, the common denominator of ischemia within all ischemic organs, played no apparent role. The direct neuroprotective potential of pharmacological NOX4 inhibition was confirmed in an ex vivo model, free of vascular and BBB components. Our results demonstrate that the heightened sensitivity of the brain to ischemic damage is due to an organ-specific role of NOX4 in blood-brain-barrier endothelial cells and neurons. This mechanism is conserved in at least two rodents and humans, making NOX4 a prime target for a first-in-class mechanism-based, cytoprotective therapy in the unmet high medical need indication of ischemic stroke. Copyright © 2017 the Author(s). Published by PNAS.

  18. LHC II system sensitivity to magnetic fluids

    CERN Document Server

    Cotae, Vlad

    2005-01-01

    Experiments have been designed to reveal the influences of ferrofluid treatment and static magnetic field exposure on the photosynthetic system II, where the light harvesting complex (LHC II) controls the ratio chlorophyll a/ chlorophyll b (revealing, indirectly, the photosynthesis rate). Spectrophotometric measurement of chlorophyll content revealed different influences for relatively low ferrofluid concentrations (10-30 mul/l) in comparison to higher concentrations (70-100 mul/l). The overlapped effect of the static magnetic field shaped better the stimulatory ferrofluid action on LHC II system in young poppy plantlets.

  19. Highly Sensitive Magnetic-SERS Dual-Function Silica Nanoprobes for Effective On-Site Organic Chemical Detection

    Science.gov (United States)

    Jeong, Cheolhwan; Kim, Hyung-Mo; Park, So Yeon; Cha, Myeong Geun; Park, Sung-Jun; Kyeong, San; Pham, Xuan-Hung; Hahm, Eunil; Ha, Yuna; Jeong, Dae Hong; Jun, Bong-Hyun; Lee, Yoon-Sik

    2017-01-01

    We report magnetic silver nanoshells (M-AgNSs) that have both magnetic and SERS properties for SERS-based detection. The M-AgNSs are composed of hundreds of Fe3O4 nanoparticles for rapid accumulation and bumpy silver shell for sensitive SERS detection by near-infrared laser excitation. The intensity of the SERS signal from the M-AgNSs was strong enough to provide single particle-level detection. We obtained much stronger SERS signal intensity from the aggregated M-AgNSs than from the non-aggregated AgNSs. 4-Fluorothiophenol was detected at concentrations as low as 1 nM, which corresponds to 0.16 ppb. The limit of detection for tetramethylthiuram disulfide was 10 μM, which corresponds to 3 ppm. The M-AgNSs can be used to detect trace amounts of organic molecules using a portable Raman system. PMID:28608835

  20. Highly Sensitive Magnetic-SERS Dual-Function Silica Nanoprobes for Effective On-Site Organic Chemical Detection

    Directory of Open Access Journals (Sweden)

    Cheolhwan Jeong

    2017-06-01

    Full Text Available We report magnetic silver nanoshells (M-AgNSs that have both magnetic and SERS properties for SERS-based detection. The M-AgNSs are composed of hundreds of Fe3O4 nanoparticles for rapid accumulation and bumpy silver shell for sensitive SERS detection by near-infrared laser excitation. The intensity of the SERS signal from the M-AgNSs was strong enough to provide single particle-level detection. We obtained much stronger SERS signal intensity from the aggregated M-AgNSs than from the non-aggregated AgNSs. 4-Fluorothiophenol was detected at concentrations as low as 1 nM, which corresponds to 0.16 ppb. The limit of detection for tetramethylthiuram disulfide was 10 μM, which corresponds to 3 ppm. The M-AgNSs can be used to detect trace amounts of organic molecules using a portable Raman system.

  1. Expression of CD73 slows down migration of skin dendritic cells, affecting the sensitization phase of contact hypersensitivity reactions in mice.

    Science.gov (United States)

    Neuberger, A; Ring, S; Silva-Vilches, C; Schrader, J; Enk, A; Mahnke, K

    2017-09-01

    Application of haptens to the skin induces release of immune stimulatory ATP into the extracellular space. This "danger" signal can be converted to immunosuppressive adenosine (ADO) by the action of the ectonucleotidases CD39 and CD73, expressed by skin and immune cells. Thus, the expression and regulation of CD73 by skin derived cells may have crucial influence on the outcome of contact hypersensitivity (CHS) reactions. To investigate the role of CD73 expression during 2,4,6-trinitrochlorobenzene (TNCB) induced CHS reactions. Wild type (wt) and CD73 deficient mice were subjected to TNCB induced CHS. In the different mouse strains the resulting ear swelling reaction was recorded along with a detailed phenotypic analysis of the skin migrating subsets of dendritic cells (DC). In CD73 deficient animals the motility of DC was higher as compared to wt animals and in particular after sensitization we found increased migration of Langerin + DC from skin to draining lymph nodes (LN). In the TNCB model this led to a stronger sensitization as indicated by increased frequency of interferon-γ producing T cells in the LN and an increased ear thickness after challenge. CD73 derived ADO production slows down migration of Langerin + DC from skin to LN. This may be a crucial mechanism to avoid over boarding immune reactions against haptens. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  2. Method for the detection of a magnetic field utilizing a magnetic vortex

    Science.gov (United States)

    Novosad, Valentyn [Chicago, IL; Buchanan, Kristen [Batavia, IL

    2010-04-13

    The determination of the strength of an in-plane magnetic field utilizing one or more magnetically-soft, ferromagnetic member, having a shape, size and material whereas a single magnetic vortex is formed at remanence in each ferromagnetic member. The preferred shape is a thin circle, or dot. Multiple ferromagnetic members can also be stacked on-top of each other and separated by a non-magnetic spacer. The resulting sensor is hysteresis free. The sensor's sensitivity, and magnetic saturation characteristics may be easily tuned by simply altering the material, size, shape, or a combination thereof to match the desired sensitivity and saturation characteristics. The sensor is self-resetting at remanence and therefore does not require any pinning techniques.

  3. Mechanistic insight provided by glutaredoxin within a fusion to redox-sensitive yellow fluorescent protein

    DEFF Research Database (Denmark)

    Björnberg, Olof; Østergaard, Henrik; Winther, Jakob R

    2006-01-01

    Redox-sensitive yellow fluorescent protein (rxYFP) contains a dithiol disulfide pair that is thermodynamically suitable for monitoring intracellular glutathione redox potential. Glutaredoxin 1 (Grx1p) from yeast is known to catalyze the redox equilibrium between rxYFP and glutathione, and here, we...... have generated a fusion of the two proteins, rxYFP-Grx1p. In comparison to isolated subunits, intramolecular transfer of reducing equivalents made the fusion protein kinetically superior in reactions with glutathione. The rate of GSSG oxidation was thus improved by a factor of 3300. The reaction...... separately and in the fusion. This could not be ascribed to the lack of an unproductive side reaction to glutaredoxin disulfide. Instead, slower alkylation kinetics with iodoacetamide indicates a better leaving-group capability of the remaining cysteine residue, which can explain the increased activity....

  4. The Possibility of Quantum Deflagration in the Fe8 Nano-Magnet

    Science.gov (United States)

    Leviant, Tom; Zeldov, Eli; Myasoedov, Yuri; Keren, Amit

    2014-03-01

    We report spatially resolved, time-dependent, magnetization reversal measurements of Fe8 single crystals using a microscopic Hall bar array. We found that in some samples the molecules reverse their spin direction at the resonance field in the form of deflagration. The deflagration front velocity is on the order of 1 m/sec and sensitive to field gradients and sweep rates. We discuss the possibility that this slow deflagration can be explained by flipping rates determined by the tunnel splitting only, with no over-the-barrier motion.

  5. Sensitive electrochemical monitoring of nucleic acids coupling DNA nanostructures with hybridization chain reaction

    International Nuclear Information System (INIS)

    Zhuang, Junyang; Fu, Libing; Xu, Mingdi; Yang, Huanghao; Chen, Guonan; Tang, Dianping

    2013-01-01

    Graphical abstract: -- Highlights: •A new signal-on metallobioassay was developed for detection of nucleic acids. •Target-triggered long-range self-assembled DNA nanostructures are used for amplification of electronic signal. •Hybridization chain reaction is utilized for construction of long-range DNA nanostructures. -- Abstract: Methods based on metal nanotags have been developed for metallobioassay of nucleic acids, but most involve complicated labeling or stripping procedures and are unsuitable for routine use. Herein, we report the proof-of-concept of a novel and label-free metallobioassay for ultrasensitive electronic determination of human immunodeficiency virus (HIV)-related gene fragments at an ultralow concentration based on target-triggered long-range self-assembled DNA nanostructures and DNA-based hybridization chain reaction (HCR). The signal is amplified by silver nanotags on the DNA duplex. The assay mainly consists of capture probe, detection probe, and two different DNA hairpins. In the presence of target DNA, the capture probe immobilized on the sensor sandwiches target DNA with the 3′ end of detection probe. Another exposed part of detection probe at the 5′ end opens two alternating DNA hairpins in turn, and propagates a chain reaction of hybridization events to form a nicked double-helix. Finally, numerous silver nanotags are immobilized onto the long-range DNA nanostructures, each of which produces a strong electronic signal within the applied potentials. Under optimal conditions, the target-triggered long-range DNA nanostructures present good electrochemical behaviors for the detection of HIV DNA at a concentration as low as 0.5 fM. Importantly, the outstanding sensitivity can make this approach a promising scheme for development of next-generation DNA sensors without the need of enzyme labeling or fluorophore labeling

  6. Inhibition of heat-shock protein 90 sensitizes liver cancer stem-like cells to magnetic hyperthermia and enhances anti-tumor effect on hepatocellular carcinoma-burdened nude mice

    Science.gov (United States)

    Yang, Rui; Tang, Qiusha; Miao, Fengqin; An, Yanli; Li, Mengfei; Han, Yong; Wang, Xihui; Wang, Juan; Liu, Peidang; Chen, Rong

    2015-01-01

    Purpose To explore the thermoresistance and expression of heat-shock protein 90 (HSP90) in magnetic hyperthermia-treated human liver cancer stem-like cells (LCSCs) and the effects of a heat-shock protein HSP90 inhibitor 17-allylamino-17-demethoxgeldanamycin (17-AAG) on hepatocellular carcinoma-burdened nude mice. Methods CD90+ LCSCs were isolated by magnetic-activated cell sorting from BEL-7404. Spheroid formation, proliferation, differentiation, drug resistance, and tumor formation assays were performed to identify stem cell characteristics. CD90-targeted thermosensitive magnetoliposomes (TMs)-encapsulated 17-AAG (CD90@17-AAG/TMs) was prepared by reverse-phase evaporation and its characteristics were studied. Heat tolerance in CD90+ LCSCs and the effect of CD90@17-AAG/TMs-mediated heat sensitivity were examined in vitro and in vivo. Results CD90+ LCSCs showed significant stem cell-like properties. The 17-AAG/TMs were successfully prepared and were spherical in shape with an average size of 128.9±7.7 nm. When exposed to magnetic hyperthermia, HSP90 was up-regulated in CD90+ LCSCs. CD90@17-AAG/TMs inhibited the activity of HSP90 and increased the sensitivity of CD90+ LCSCs to magnetic hyperthermia. Conclusion The inhibition of HSP90 could sensitize CD90+ LCSCs to magnetic hyperthermia and enhance its anti-tumor effects in vitro and in vivo. PMID:26677324

  7. Explaining the atypical reaction profiles of heme enzymes with a novel mechanistic hypothesis and kinetic treatment.

    Directory of Open Access Journals (Sweden)

    Kelath Murali Manoj

    Full Text Available Many heme enzymes show remarkable versatility and atypical kinetics. The fungal extracellular enzyme chloroperoxidase (CPO characterizes a variety of one and two electron redox reactions in the presence of hydroperoxides. A structural counterpart, found in mammalian microsomal cytochrome P450 (CYP, uses molecular oxygen plus NADPH for the oxidative metabolism (predominantly hydroxylation of substrate in conjunction with a redox partner enzyme, cytochrome P450 reductase. In this study, we employ the two above-mentioned heme-thiolate proteins to probe the reaction kinetics and mechanism of heme enzymes. Hitherto, a substrate inhibition model based upon non-productive binding of substrate (two-site model was used to account for the inhibition of reaction at higher substrate concentrations for the CYP reaction systems. Herein, the observation of substrate inhibition is shown for both peroxide and final substrate in CPO catalyzed peroxidations. Further, analogy is drawn in the "steady state kinetics" of CPO and CYP reaction systems. New experimental observations and analyses indicate that a scheme of competing reactions (involving primary product with enzyme or other reaction components/intermediates is relevant in such complex reaction mixtures. The presence of non-selective reactive intermediate(s affords alternate reaction routes at various substrate/product concentrations, thereby leading to a lowered detectable concentration of "the product of interest" in the reaction milieu. Occam's razor favors the new hypothesis. With the new hypothesis as foundation, a new biphasic treatment to analyze the kinetics is put forth. We also introduce a key concept of "substrate concentration at maximum observed rate". The new treatment affords a more acceptable fit for observable experimental kinetic data of heme redox enzymes.

  8. Levitation of a magnet by an alternating magnetic field

    International Nuclear Information System (INIS)

    Gough, W; Hunt, M O; Summerskill, W S H

    2013-01-01

    An experiment is described in which a small strong cylindrical magnet is levitated by a vertical non-uniform alternating magnetic field. Surprisingly, no superimposed constant field is necessary, but the levitation can be explained when the vertical motion of the magnet is taken into account. The theoretical mean levitation force is (0.26 ± 0.06) N, which is in good agreement with the levitated weight of (0.239 ± 0.001) N. This experiment is suitable for an undergraduate laboratory, particularly as a final year project. Students have found it interesting, and it sharpens up knowledge of basic magnetism. (paper)

  9. Sodium-concrete reaction model development

    International Nuclear Information System (INIS)

    Nguyen, D.H.; Muhlestein, L.D.; Postma, A.K.

    1982-07-01

    Major observations have been formulated after reviewing test results for over 100 sodium-concrete reaction tests. The observations form the basis for developing a mechanistic model to predict the transient behavior of sodium-concrete reactions. The major observations are listed. Mechanisms associated with sodium and water transport to the reaction zone are identified, and represented by appropriate mathematical expressions. The model attempts to explain large-scale, long-term (100 h) test results were sodium-concrete reactions terminated even in the presence of unreacted sodium and concrete

  10. Spontaneous magnetic alignment behaviour in free-living lizards

    Science.gov (United States)

    Diego-Rasilla, Francisco J.; Pérez-Mellado, Valentín; Pérez-Cembranos, Ana

    2017-04-01

    Several species of vertebrates exhibit spontaneous longitudinal body axis alignment relative to the Earth's magnetic field (i.e., magnetic alignment) while they are performing different behavioural tasks. Since magnetoreception is still not fully understood, studying magnetic alignment provides evidence for magnetoreception and broadens current knowledge of magnetic sense in animals. Furthermore, magnetic alignment widens the roles of magnetic sensitivity in animals and may contribute to shed new light on magnetoreception. In this context, spontaneous alignment in two species of lacertid lizards ( Podarcis muralis and Podarcis lilfordi) during basking periods was monitored. Alignments in 255 P. muralis and 456 P. lilfordi were measured over a 5-year period. The possible influence of the sun's position (i.e., altitude and azimuth) and geomagnetic field values corresponding to the moment in which a particular lizard was observed on lizards' body axis orientation was evaluated. Both species exhibited a highly significant bimodal orientation along the north-northeast and south-southwest magnetic axis. The evidence from this study suggests that free-living lacertid lizards exhibit magnetic alignment behaviour, since their body alignments cannot be explained by an effect of the sun's position. On the contrary, lizard orientations were significantly correlated with geomagnetic field values at the time of each observation. We suggest that this behaviour might provide lizards with a constant directional reference while they are sun basking. This directional reference might improve their mental map of space to accomplish efficient escape behaviour. This study is the first to provide spontaneous magnetic alignment behaviour in free-living reptiles.

  11. A cell for extended x-ray absorption fine structure studies of oxygen sensitive products of redox reactions

    International Nuclear Information System (INIS)

    Furenlid, L.R.; Renner, M.W.; Fajer, J.

    1990-01-01

    We describe a cell suitable for extended x-ray absorption fine structure (EXAFS) studies of oxygen and/or water sensitive products of redox reactions. The cell utilizes aluminized Mylar windows that are transparent to x rays, provide low gas permeability, and allow vacuum to be maintained in the cell. The windows are attached to the glassware with an epoxy that resists attack by common organic solvents. Additional side arms allow multiple spectroscopic probes of the same sample under anaerobic and anhydrous conditions

  12. Copper-Based Metal-Organic Framework Nanoparticles with Peroxidase-Like Activity for Sensitive Colorimetric Detection of Staphylococcus aureus.

    Science.gov (United States)

    Wang, Shuqin; Deng, Wenfang; Yang, Lu; Tan, Yueming; Xie, Qingji; Yao, Shouzhuo

    2017-07-26

    Cu-MOF nanoparticles with an average diameter of 550 nm were synthesized from 2-aminoterephthalic acid and Cu(NO 3 ) 2 by a mixed solvothermal method. The Cu-MOF nanoparticles can show peroxidase-like activity that can catalyze 3,3',5,5'-tetramethylbenzidine to produce a yellow chromogenic reaction in the presence of H 2 O 2 . The presence of abundant amine groups on the surfaces of Cu-MOF nanoparticles enables facile modification of Staphylococcus aureus (S. aureus) aptamer on Cu-MOF nanoparticles. By combining Cu-MOF-catalyzed chromogenic reaction with aptamer recognition and magnetic separation, a simple, sensitive, and selective colorimetric method for the detection of S. aureus was developed.

  13. Magnetic anisotropy considerations in magnetic force microscopy studies of single superparamagnetic nanoparticles

    International Nuclear Information System (INIS)

    Nocera, Tanya M; Agarwal, Gunjan; Chen Jun; Murray, Christopher B

    2012-01-01

    In recent years, superparamagnetic nanoparticles (SPNs) have become increasingly important in applications ranging from solid state memory devices to biomedical diagnostic and therapeutic tools. However, detection and characterization of the small and unstable magnetic moment of an SPN at the single particle level remains a challenge. Further, depending on their physical shape, crystalline structure or orientation, SPNs may also possess magnetic anisotropy, which can govern the extent to which their magnetic moments can align with an externally applied magnetic field. Here, we demonstrate how we can exploit the magnetic anisotropy of SPNs to enable uniform, highly-sensitive detection of single SPNs using magnetic force microscopy (MFM) in ambient air. Superconducting quantum interference device magnetometry and analytical transmission electron microscopy techniques are utilized to characterize the collective magnetic behavior, morphology and composition of the SPNs. Our results show how the consideration of magnetic anisotropy can enhance the ability of MFM to detect single SPNs at ambient room temperature with high force sensitivity and spatial resolution. (paper)

  14. /sup 56/Fe (. gamma. ,. cap alpha. /sub 0/) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tamae, T; Sugawara, M [Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science; Tsubota, H

    1974-12-01

    The reaction cross section of /sup 56/Fe (..gamma.., ..cap alpha../sub 0/) was measured from the electron energy of 15 to 25 MeV. The measured data were compared with the calculated ones based on statistic theory. Both agreed with each other. Therefore, the affirmative result was obtained for the presumption that the reaction of (..gamma.., ..cap alpha../sub 0/) of the nuclei around these energy levels can be explained by the statistical theory. The angular distribution of /sup 56/Fe (..gamma.., ..cap alpha../sub 0/) with 17 MeV electron energy was also measured, and the E2/E1 ratio was obtained. In the measurement of the /sup 56/Fe ( Gamma , ..cap alpha../sub 0/) reaction cross section, a natural target of 2.69 mg/cm/sup 2/ was irradiated with an electron beam with energy from 15 MeV to 25 MeV at intervals of 0.5 MeV, and the emitted ..cap alpha.. particles were detected by a broad band magnetic distribution meter. The measured cross section of the (..gamma.., ..cap alpha../sub 0/) reaction agreed with the calculated one based on statistical theory. If this fact is recognized in many nuclei, the cross section of the (..gamma.., ..cap alpha../sub 0/) reaction on those nuclei has the following characteristics. When the increasing rate of the product of a complex nucleus formation cross section and ..cap alpha../sub 0/ penetration factor is larger than that of the sum of all penetration factors of possible channels, the cross section of the (..gamma.., ..cap alpha../sub 0/) reaction increases, and takes a peak value when the above two increasing rates agree with each other.

  15. Anxiety sensitivity explains associations between anxious arousal symptoms and smoking abstinence expectancies, perceived barriers to cessation, and problems experienced during past quit attempts among low-income smokers.

    Science.gov (United States)

    Zvolensky, Michael J; Paulus, Daniel J; Langdon, Kirsten J; Robles, Zuzuky; Garey, Lorra; Norton, Peter J; Businelle, Michael S

    2017-05-01

    Disproportionately more smokers report low-income and mental health problems relative to non-smokers. Low-income smokers may use smoking to alleviate negative emotional states resulting from exposure to multiple stressors. Yet, little work has been devoted to elucidating mechanisms that may explain the association between negative emotional states and smoking-related processes among low-income smokers. The present study sought to address this gap by examining anxiety sensitivity, a transdiagnostic factor related to both anxiety and smoking, as a potential mediator for the influence of anxiety symptoms on smoking-related processes, including threat-related smoking abstinence expectancies (somatic symptoms and harmful consequences), perceived barriers for cessation, and problems experienced during past quit attempts. Participants included treatment-seeking daily cigarette smokers (n=101; 68.3% male; M age =47.1; SD=10.2). Results indicated that anxiety symptoms exerted a significant indirect effect through anxiety sensitivity for threat-related smoking abstinence expectancies (somatic symptoms and harmful consequences), perceived barriers for cessation, and problems experienced during past quit attempts. The present results provide empirical support that anxiety sensitivity may be an underlying mechanism that partially explains the relation between anxiety symptoms and smoking processes among low-income treatment-seeking smokers. Findings broaden current theoretical understanding of pathways through which anxiety symptoms contribute to maladaptive smoking processes and cognitions among socioeconomically disadvantaged smokers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Reaction kinetics and mechanism of magnetic field effects in cryptochrome

    DEFF Research Database (Denmark)

    Solov'yov, Ilia; Schulten, Klaus

    2012-01-01

    Creatures as varied as mammals, fish, insects, reptiles, and birds have an intriguing sixth sense that allows them to orient themselves in the Earth's magnetic field. Despite decades of study, the physical basis of this magnetic sense remains elusive. A likely mechanism is furnished by magnetically...

  17. Negative magnetic relaxation in superconductors

    Directory of Open Access Journals (Sweden)

    Krasnoperov E.P.

    2013-01-01

    Full Text Available It was observed that the trapped magnetic moment of HTS tablets or annuli increases in time (negative relaxation if they are not completely magnetized by a pulsed magnetic field. It is shown, in the framework of the Bean critical-state model, that the radial temperature gradient appearing in tablets or annuli during a pulsed field magnetization can explain the negative magnetic relaxation in the superconductor.

  18. Calibration of an analyzing magnet using the 12C(d, p0)13C nuclear reaction with a thick carbon target

    Science.gov (United States)

    Andrade, E.; Canto, C. E.; Rocha, M. F.

    2017-09-01

    The absolute energy of an ion beam produced by an accelerator is usually determined by an electrostatic or magnetic analyzer, which in turn must be calibrated. Various methods for accelerator energy calibration are extensively reported in the literature, like nuclear reaction resonances, neutron threshold, and time of flight, among others. This work reports on a simple method to calibrate the magnet associated to a vertical 5.5 MV Van de Graaff accelerator. The method is based on bombarding with deuteron beams a thick carbon target and measuring with a surface barrier detector the particle energy spectra produced. The analyzer magnetic field is measured for each spectrum and the beam energy is deduced by the best fit of the simulation of the spectrum with the SIMNRA code that includes 12C(d,p0)13C nuclear cross sections.

  19. Spontaneous magnetic alignment by yearling snapping turtles: rapid association of radio frequency dependent pattern of magnetic input with novel surroundings.

    Science.gov (United States)

    Landler, Lukas; Painter, Michael S; Youmans, Paul W; Hopkins, William A; Phillips, John B

    2015-01-01

    We investigated spontaneous magnetic alignment (SMA) by juvenile snapping turtles using exposure to low-level radio frequency (RF) fields at the Larmor frequency to help characterize the underlying sensory mechanism. Turtles, first introduced to the testing environment without the presence of RF aligned consistently towards magnetic north when subsequent magnetic testing conditions were also free of RF ('RF off → RF off'), but were disoriented when subsequently exposed to RF ('RF off → RF on'). In contrast, animals initially introduced to the testing environment with RF present were disoriented when tested without RF ('RF on → RF off'), but aligned towards magnetic south when tested with RF ('RF on → RF on'). Sensitivity of the SMA response of yearling turtles to RF is consistent with the involvement of a radical pair mechanism. Furthermore, the effect of RF appears to result from a change in the pattern of magnetic input, rather than elimination of magnetic input altogether, as proposed to explain similar effects in other systems/organisms. The findings show that turtles first exposed to a novel environment form a lasting association between the pattern of magnetic input and their surroundings. However, under natural conditions turtles would never experience a change in the pattern of magnetic input. Therefore, if turtles form a similar association of magnetic cues with the surroundings each time they encounter unfamiliar habitat, as seems likely, the same pattern of magnetic input would be associated with multiple sites/localities. This would be expected from a sensory input that functions as a global reference frame, helping to place multiple locales (i.e., multiple local landmark arrays) into register to form a global map of familiar space.

  20. Allergic reactions to vespids: comparison of sensitivities to two species in a Mediterranean area.

    Science.gov (United States)

    Blanca, M; Miranda, A; Fernandez, J; Terrados, S; Vela, J M; Vega, J M; Gonzalez, J J; Juarez, C

    1988-01-01

    We have studied a group of twenty-seven patients who suffer allergic reactions to vespids stings. Specific IgE antibodies to venom extracts from Polistes gallicus and Vespula germanica were measured by RAST, and the crossreactivity between the two venoms was compared using the RAST inhibition technique. We concluded that, in southern Spain, sensitization to P. gallicus was more prevalent than that to V. germanica, with 44% of the subjects in this study reacting to P. gallicus compared with 33% to V. germanica. However, there was a considerable degree of crossreactivity between the two species. It is evident that Polistes is an important species in this area; however, both in Spain and other Mediterranean countries, V. germanica venom is used almost exclusively for diagnosis and immunotherapy.

  1. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    Science.gov (United States)

    Lima, E. A.; Bruno, A. C.; Carvalho, H. R.; Weiss, B. P.

    2014-10-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x-y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10-14 A m2, a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays.

  2. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    International Nuclear Information System (INIS)

    Lima, E A; Weiss, B P; Bruno, A C; Carvalho, H R

    2014-01-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x–y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz 1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10 –14  A m 2 , a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays. (paper)

  3. Sensitive electrochemical assaying of DNA methyltransferase activity based on mimic-hybridization chain reaction amplified strategy.

    Science.gov (United States)

    Zhang, Linqun; Liu, Yuanjian; Li, Ying; Zhao, Yuewu; Wei, Wei; Liu, Songqin

    2016-08-24

    A mimic-hybridization chain reaction (mimic-HCR) amplified strategy was proposed for sensitive electrochemically detection of DNA methylation and methyltransferase (MTase) activity In the presence of methylated DNA, DNA-gold nanoparticles (DNA-AuNPs) were captured on the electrode by sandwich-type assembly. It then triggered mimic-HCR of two hairpin probes to produce many long double-helix chains for numerous hexaammineruthenium (III) chloride ([Ru(NH3)6](3+), RuHex) inserting. As a result, the signal for electrochemically detection of DNA MTase activity could be amplified. If DNA was non-methylated, however, the sandwich-type assembly would not form because the short double-stranded DNAs (dsDNA) on the Au electrode could be cleaved and digested by restriction endonuclease HpaII (HapII) and exonuclease III (Exo III), resulting in the signal decrement. Based on this, an electrochemical approach for detection of M.SssI MTase activity with high sensitivity was developed. The linear range for M.SssI MTase activity was from 0.05 U mL(-1) to 10 U mL(-1), with a detection limit down to 0.03 U mL(-1). Moreover, this detecting strategy held great promise as an easy-to-use and highly sensitive method for other MTase activity and inhibition detection by exchanging the corresponding DNA sequence. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Chelating capture and magnetic removal of non-magnetic heavy metal substances from soil

    OpenAIRE

    Liren Fan; Jiqing Song; Wenbo Bai; Shengping Wang; Ming Zeng; Xiaoming Li; Yang Zhou; Haifeng Li; Haiwei Lu

    2016-01-01

    A soil remediation method based on magnetic beneficiation is reported. A new magnetic solid chelator powder, FS@IDA (core-shell Fe3O4@SiO2 nanoparticles coated with iminodiacetic acid chelators), was used as a reactive magnetic carrier to selectively capture non-magnetic heavy metals in soil by chelation and removal by magnetic separation. FS@IDA was prepared via inorganic-organic and organic synthesis reactions that generated chelating groups on the surface of magnetic, multi-core, core-shel...

  5. Continuous monitoring of the zinc-phosphate acid-base cement setting reaction by proton nuclear magnetic relaxation

    International Nuclear Information System (INIS)

    Apih, T.; Lebar, A.; Pawlig, O.; Trettin, R.

    2001-01-01

    Proton nuclear magnetic relaxation is a well-established technique for continuous and non destructive monitoring of hydration of conventional Portland building cements. Here, we demonstrate the feasibility of nuclear magnetic resonance (NMR) monitoring of the setting reaction of zinc-phosphate acid-base dental cements, which harden in minutes as compared to days, as in the case of Portland cements. We compare the setting of cement powder (mainly, zinc oxide) prepared with clinically used aluminum-modified orthophosphoric acid solution with the setting of a model system where cement powder is mixed with pure orthophosphoric acid solution. In contrast to previously published NMR studies of setting Portland cements, where a decrease of spin-lattice relaxation time is attributed to enhanced relaxation at the growing internal surface, spin-lattice relaxation time T 1 increases during the set of clinically used zinc-phosphate cement. Comparison of these results with a detailed study of diffusion, viscosity, and magnetic-field dispersion of T 1 in pure and aluminum-modified orthophosphoric acid demonstrates that the increase of T 1 in the setting cement is connected with the increase of molecular mobility in the residual phosphoric acid solution. Although not taken into account so far, such effects may also significantly influence the relaxation times in setting Portland cements, particularly when admixtures with an effect on water viscosity are used. [copyright] 2001 American Institute of Physics

  6. Extremely high magnetic-field sensitivity of charge transport in the Mn/SiO2/p-Si hybrid structure

    Directory of Open Access Journals (Sweden)

    N. V. Volkov

    2017-01-01

    Full Text Available We report on abrupt changes in dc resistance and impedance of a diode with the Schottky barrier based on the Mn/SiO2/p-Si structure in a magnetic field. It was observed that at low temperatures the dc and ac resistances of the device change by a factor of more than 106 with an increase in a magnetic field to 200 mT. The strong effect of the magnetic field is observed only above the threshold forward bias across the diode. The ratios between ac and dc magnetoresistances can be tuned from almost zero to 108% by varying the bias. To explain the diversity of magnetotransport phenomena observed in the Mn/SiO2/p-Si structure, it is necessary to attract several mechanisms, which possibly work in different regions of the structure. The anomalously strong magnetotransport effects are attributed to the magnetic-field-dependent impact ionization in the bulk of a Si substrate. At the same time, the conditions for this process are specified by structure composition, which, in turn, affects the current through each structure region. The effect of magnetic field attributed to suppression of impact ionization via two mechanisms leads to an increase in the carrier energy required for initiation of impact ionization. The first mechanism is related to displacement of acceptor levels toward higher energies relative to the top of the valence band and the other mechanism is associated with the Lorentz forces affecting carrier trajectories between scatterings events. The estimated contributions of these two mechanisms are similar. The proposed structure is a good candidate for application in CMOS technology-compatible magnetic- and electric-field sensors and switching devices.

  7. The Sensitization Model to Explain How Chronic Pain Exists Without Tissue Damage

    NARCIS (Netherlands)

    van Wilgen, C. Paul; Keizer, Doeke

    The interaction of nurses with chronic pain patients is often difficult. One of the reasons is that chronic pain is difficult to explain, because no obvious anatomic defect or tissue damage is present. There is now enough evidence available indicating that chronic pain syndromes such as low back

  8. Biomarker detection of global infectious diseases based on magnetic particles.

    Science.gov (United States)

    Carinelli, Soledad; Martí, Mercè; Alegret, Salvador; Pividori, María Isabel

    2015-09-25

    Infectious diseases affect the daily lives of millions of people all around the world, and are responsible for hundreds of thousands of deaths, mostly in the developing world. Although most of these major infectious diseases are treatable, the early identification of individuals requiring treatment remains a major issue. The incidence of these diseases would be reduced if rapid diagnostic tests were widely available at the community and primary care level in low-resource settings. Strong research efforts are thus being focused on replacing standard clinical diagnostic methods, such as the invasive detection techniques (biopsy or endoscopy) or expensive diagnostic and monitoring methods, by affordable and sensitive tests based on novel biomarkers. The development of new methods that are needed includes solid-phase separation techniques. In this context, the integration of magnetic particles within bioassays and biosensing devices is very promising since they greatly improve the performance of a biological reaction. The diagnosis of clinical samples with magnetic particles can be easily achieved without pre-enrichment, purification or pretreatment steps often required for standard methods, simplifying the analytical procedures. The biomarkers can be specifically isolated and preconcentrated from complex biological matrixes by magnetic actuation, increasing specificity and the sensitivity of the assay. This review addresses these promising features of the magnetic particles for the detection of biomarkers in emerging technologies related with infectious diseases affecting global health, such as malaria, influenza, dengue, tuberculosis or HIV. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Interstellar Matters: Neutral Hydrogen and the Galactic Magnetic Field

    Science.gov (United States)

    Verschuur, Gerrit; Schmelz, Joan T.; Asgari-Targhi asgari-Targhi, M.

    2018-01-01

    The physics of the interstellar medium was revolutionized by the observations of the Galactic Arecibo L-Band Feed Array (GALFA) HI survey done at the Arecibo Observatory. The high-resolution, high-sensitivity, high-dynamic- range images show complex, tangled, extended filaments, and reveal that the fabric of the neutral interstellar medium is deeply tied to the structure of the ambient magnetic field. This discovery prompts an obvious question – how exactly is the interstellar {\\it neutral} hydrogen being affected by the galactic magnetic field? We look into this question by examining a set of GALFA-HI data in great detail. We have chosen a long, straight filament in the southern galactic sky. This structure is both close by and isolated in velocity space. Gaussian analysis of profiles both along and across the filament reveal internal structure – braided strands that can be traced through the simplest part, but become tangled in more complex segments. These braids do not resemble in any way the old spherical HI clouds and rudimentary pressure balance models that were used to explain the pre-GALFA- HI interstellar medium. It is clear that these structures are created, constrained, and dominated by magnetic fields. Like many subfields of astronomy before it, e.g., physics of the solar coronal, extragalactic radio jets, and pulsar environment, scientists are confronted with observations that simply cannot be explained by simple hydrodynamics and are forced to consider magneto-hydrodynamics.

  10. Further important sensitizers in patients sensitive to fragrances

    DEFF Research Database (Denmark)

    Frosch, Peter J; Johansen, J D; Menné, T

    2002-01-01

    (series I). Each patient was classified regarding a history of adverse reactions to fragrances: certain, probable, questionable, none. Reactions to FM occurred in 11.3% of the subjects. The 6 substances with the highest reactivity following FM were Lyral (2.7%), citral (1.1%), farnesol P (0...... further sensitizers relevant for patch testing of patients with contact dermatitis, of which Lyral is the most important single chemical....

  11. Features of magnetic susceptibility and inhomogeneous magnetic state in La-Sr manganites

    International Nuclear Information System (INIS)

    Dovgij, V.T.; Linnik, A.I.; Kamenev, V.I.; Prokopenko, V.K.; Mikhajlov, V.I.; Khokhlov, V.A.; Kadontseva, A.M.; Linnik, T.A.; Davydejko, N.V.; Turchenko, V.A.

    2007-01-01

    Anomalous magnetic susceptibility has been observed in mono- and polycrystalline (ceramic) samples of La-Sr manganites. The oscillations of the magnetic susceptibility observed for monocrystal samples in the vicinity of the Curie temperature (and in the paramagnetic region) are explained by the existence of magnetic clusters. The appearance of susceptibility oscillations in ceramic samples is attributed to the formation of magnetic clusters, which may occur both in grains (at the interface between ferro- and antiferromagnetic phases) and at the grain boundaries [ru

  12. Magnetic field line Hamiltonian

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1984-03-01

    The magnetic field line Hamiltonian and the associated canonical form for the magnetic field are important concepts both for understanding toroidal plasma physics and for practical calculations. A number of important properties of the canonical or Hamiltonian representation are derived and their importance is explained

  13. Thermally activated magnetization reversal in magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Guang-Hong, Zhou; Yin-Gang, Wang; Xian-Jin, Qi; Zi-Quan, Li; Jian-Kang, Chen

    2009-01-01

    In this paper, the magnetization reversal of the ferromagnetic layers in the IrMn/CoFe/AlO x /CoFe magnetic tunnel junction has been investigated using bulk magnetometry. The films exhibit very complex magnetization processes and reversal mechanism. Thermal activation phenomena such as the training effect, the asymmetry of reversal, the loop broadening and the decrease of exchange field while holding the film at negative saturation have been observed on the hysteresis loops of the pinned ferromagnetic layer while not on those of the free ferromagnetic layer. The thermal activation phenomena observed can be explained by the model of two energy barrier distributions with different time constants. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  14. Sensitivitas dan Spesifisitas Nested Polymerase Chain Reaction untuk Mendeteksi DNA Coxiella burnetii (SENSITIVITY AND SPECIFICITY OF NESTED POLYMERASE CHAIN REACTION FOR DETECTION OF COXIELLA BURNETII DNA

    Directory of Open Access Journals (Sweden)

    Trioso Purnawarman

    2014-04-01

    Full Text Available Sensitivity and specificity of nested polymerase chain reaction (nested PCR to detect Coxiella burnetii(C. burnetii DNA were studied. The primer system which consists of external primers (OMP1 and OMP2and internal primers (OMP3 and OMP4, was designed from the nucleotide sequence of the com I geneencoding for 27 kDa outer membrane protein and used to specifically amplify a 501 bp and 438 bp fragment.This nested PCR assay was 50 fold more sensitive than that of using PCR external primer only. TheNested PCR has a detection limit as low as 300 pg/?l. Specificity studies showed that nested PCR onlydetected C. burnetii DNA and did not happened Brucella abortus, Escherichia coli, Pseudomonas aeruginosaand Campylobacter Jejuni DNA. Nested PCR has high senstively and specificaly diagnostic method of C.burnetii as agent of Q fever disease.

  15. Quantifying explainable discrimination and removing illegal discrimination in automated decision making

    KAUST Repository

    Kamiran, Faisal

    2012-11-18

    Recently, the following discrimination-aware classification problem was introduced. Historical data used for supervised learning may contain discrimination, for instance, with respect to gender. The question addressed by discrimination-aware techniques is, given sensitive attribute, how to train discrimination-free classifiers on such historical data that are discriminative, with respect to the given sensitive attribute. Existing techniques that deal with this problem aim at removing all discrimination and do not take into account that part of the discrimination may be explainable by other attributes. For example, in a job application, the education level of a job candidate could be such an explainable attribute. If the data contain many highly educated male candidates and only few highly educated women, a difference in acceptance rates between woman and man does not necessarily reflect gender discrimination, as it could be explained by the different levels of education. Even though selecting on education level would result in more males being accepted, a difference with respect to such a criterion would not be considered to be undesirable, nor illegal. Current state-of-the-art techniques, however, do not take such gender-neutral explanations into account and tend to overreact and actually start reverse discriminating, as we will show in this paper. Therefore, we introduce and analyze the refined notion of conditional non-discrimination in classifier design. We show that some of the differences in decisions across the sensitive groups can be explainable and are hence tolerable. Therefore, we develop methodology for quantifying the explainable discrimination and algorithmic techniques for removing the illegal discrimination when one or more attributes are considered as explanatory. Experimental evaluation on synthetic and real-world classification datasets demonstrates that the new techniques are superior to the old ones in this new context, as they succeed in

  16. Non-Covalent Fluorescent Labeling of Hairpin DNA Probe Coupled with Hybridization Chain Reaction for Sensitive DNA Detection.

    Science.gov (United States)

    Song, Luna; Zhang, Yonghua; Li, Junling; Gao, Qiang; Qi, Honglan; Zhang, Chengxiao

    2016-04-01

    An enzyme-free signal amplification-based assay for DNA detection was developed using fluorescent hairpin DNA probes coupled with hybridization chain reaction (HCR). The hairpin DNAs were designed to contain abasic sites in the stem moiety. Non-covalent labeling of the hairpin DNAs was achieved when a fluorescent ligand was bound to the abasic sites through hydrogen bonding with the orphan cytosine present on the complementary strand, accompanied by quench of ligand fluorescence. As a result, the resultant probes, the complex formed between the hairpin DNA and ligand, showed almost no fluorescence. Upon hybridization with target DNA, the probe underwent a dehybridization of the stem moiety containing an abasic site. The release of ligand from the abasic site to the solution resulted in an effective fluorescent enhancement, which can be used as a signal. Compared with a sensing system without HCR, a 20-fold increase in the sensitivity was achieved using the sensing system with HCR. The fluorescent intensity of the sensing system increased with the increase in target DNA concentration from 0.5 nM to 100 nM. A single mismatched target ss-DNA could be effectively discriminated from complementary target DNA. Genotyping of a G/C single-nucleotide polymorphism of polymerase chain reaction (PCR) products was successfully demonstrated with the sensing system. Therefore, integrating HCR strategy with non-covalent labeling of fluorescent hairpin DNA probes provides a sensitive and cost-effective DNA assay. © The Author(s) 2016.

  17. Selective separation of lambdacyhalothrin by porous/magnetic molecularly imprinted polymers prepared by Pickering emulsion polymerization.

    Science.gov (United States)

    Hang, Hui; Li, Chunxiang; Pan, Jianming; Li, Linzi; Dai, Jiangdong; Dai, Xiaohui; Yu, Ping; Feng, Yonghai

    2013-10-01

    Porous/magnetic molecularly imprinted polymers (PM-MIPs) were prepared by Pickering emulsion polymerization. The reaction was carried out in an oil/water emulsion using magnetic halloysite nanotubes as the stabilizer instead of a toxic surfactant. In the oil phase, the imprinting process was conducted by radical polymerization of functional and cross-linked monomers, and porogen chloroform generated steam under the high reaction temperature, which resulted in some pores decorated with easily accessible molecular binding sites within the as-made PM-MIPs. The characterization demonstrated that the PM-MIPs were porous and magnetic inorganic-polymer composite microparticles with magnetic sensitivity (M(s) = 0.7448 emu/g), thermal stability (below 473 K) and magnetic stability (over the pH range of 2.0-8.0). The PM-MIPs were used as a sorbent for the selective binding of lambdacyhalothrin (LC) and rapidly separated under an external magnetic field. The Freundlich isotherm model gave a good fit to the experimental data. The adsorption kinetics of the PM-MIPs was well described by pseudo-second-order kinetics, indicating that the chemical process could be the rate-limiting step in the adsorption of LC. The selective recognition experiments exhibited the outstanding selective adsorption effect of the PM-MIPs for target LC. Moreover, the PM-MIPs regeneration without significant loss in adsorption capacity was demonstrated by at least four repeated cycles. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Resonant nuclear reaction 23Mg (p,γ) 24Al in strongly screening magnetized neutron star crust

    Science.gov (United States)

    Liu, Jing-Jing; Liu, Dong-Mei

    2017-12-01

    Based on the relativistic theory of superstrong magnetic fields (SMF), by using three models those of Lai (LD), Fushiki (FGP), and our own (LJ), we investigate the influence of SMFs due to strong electron screening (SES) on the nuclear reaction 23Mg (p,γ) 24Al in magnetars. In a relatively low density environment (e.g., ρ 7102), our reaction rates can be 1.58 times and about three orders of magnitude larger than those of FGP and LD, respectively (B 12, ρ 7 are in units of 1012G, 107g cm-3). The significant increase of strong screening rate can imply that more 23Mg will escape from the Ne-Na cycle due to SES in a SMF. As a consequence, the next reaction, 24Al (β+, ν) 24Mg, will produce more 24Mg to participate in the Mg-Al cycle. Thus, it may lead to synthesis of a large amount of A>20 nuclides in magnetars. Supported by National Natural Science Foundation of China (11565020), the Counterpart Foundation of Sanya (2016PT43), the Special Foundation of Science and Technology Cooperation for Advanced Academy and Regional of Sanya (2016YD28), the Scientific Research Starting Foundation for 515 Talented Project of Hainan Tropical Ocean University (RHDRC201701) and the Natural Science Foundation of Hainan Province (114012)

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. Your child will lie on a moveable examination ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  1. Enhanced bimolecular exchange reaction through programmed coordination of a five-coordinate oxovanadium complex for efficient redox mediation in dye-sensitized solar cells.

    Science.gov (United States)

    Oyaizu, Kenichi; Hayo, Noriko; Sasada, Yoshito; Kato, Fumiaki; Nishide, Hiroyuki

    2013-12-07

    Electrochemical reversibility and fast bimolecular exchange reaction found for VO(salen) gave rise to a highly efficient redox mediation to enhance the photocurrent of a dye-sensitized solar cell, leading to an excellent photovoltaic performance with a conversion efficiency of 5.4%. A heterogeneous electron-transfer rate constant at an electrode (k0) and a second-order rate constant for an electron self-exchange reaction (k(ex)) were proposed as key parameters that dominate the charge transport property, which afforded a novel design concept for the mediators based on their kinetic aspects.

  2. Asymmetric H-D exchange reactions of fluorinated aromatic ketones

    KAUST Repository

    Zhao, Yujun

    2012-01-01

    Chiral bicyclic guanidine catalyzes the asymmetric H-D exchange reactions. Up to 30% ee was achieved. DFT calculations were employed to elucidate and explain the origin of the reaction\\'s stereoselectivity. © 2012 The Royal Society of Chemistry.

  3. Magnetic starspots

    International Nuclear Information System (INIS)

    Jahn, K.; Stepien, K.

    1984-01-01

    Models of large magnetic starspots with an axisymmetric untwisted magnetic field on late type stars are discussed. It is assumed that the magnetic field reduces the efficiency of convection inside the spot. A unique relation between the stellar mass and the difference of effective temperatures of the spot and the surrounding photosphere is adopted from observations. It is equivalent to the reduction of a s (the mixing length theory parameter) inside the spot to the value 0.15 independently of the stellar mass. The surface magnetic field of large spots covering a considerable part of the stellar surface is a decreasing function of the magnetic flux. Hence a coverage of a star by magnetic regions rapidly increases as a function of the magnetic flux in a narrow range of fluxes. This behaviour can explain the Vaughan-Preston gap. Recent observations of magnetic fields on G and K type stars are in a good agreement with our predictions. 35 refs., 3 figs., 4 tabs. (author)

  4. Minimizing Environmental Magnetic Field Sources for nEDM

    Science.gov (United States)

    Brinson, Alex; Filippone, Bradley; Slutsky, Simon; Osthelder, Charles

    2017-09-01

    Measurement of the neutron's Electric Dipole Moment (nEDM) could potentially explain the Baryon Asymmetry Problem, and would suggest plausible extensions to the Standard Model. We will attempt to detect the nEDM by measuring the electric-field-dependent neutron precession frequency, which is highly sensitive to magnetic field gradients. In order to produce fields with sufficiently low gradients for our experiment, we eliminate environmental effects by offsetting the ambient field with a Field Compensation System (FCS), then magnetically shielding the reduced field with a Mu-Metal cylinder. We discovered that the strongest environmental effect in our lab came from iron rebar embedded in the floor beneath the proposed experiment location. The large extent and strength of the floor's magnetization made the effect too large to offset with the FCS, forcing us to relocate our apparatus. The floor's magnetic field was mapped with a Hall probe in order to determine the most viable experiment locations. A 3-axis Fluxgate magnetometer was then used to determine the floor field's drop-off and shape at these locations, and a final apparatus position was determined which minimized the floor's effect such that it could be effectively offset and shielded by our experiment. Caltech SFP Office.

  5. The selectively bred high alcohol sensitivity (HAS) and low alcohol sensitivity (LAS) rats differ in sensitivity to nicotine.

    Science.gov (United States)

    de Fiebre, NancyEllen C; Dawson, Ralph; de Fiebre, Christopher M

    2002-06-01

    Studies in rodents selectively bred to differ in alcohol sensitivity have suggested that nicotine and ethanol sensitivities may cosegregate during selective breeding. This suggests that ethanol and nicotine sensitivities may in part be genetically correlated. Male and female high alcohol sensitivity (HAS), control alcohol sensitivity, and low alcohol sensitivity (LAS) rats were tested for nicotine-induced alterations in locomotor activity, body temperature, and seizure activity. Plasma and brain levels of nicotine and its primary metabolite, cotinine, were measured in these animals, as was the binding of [3H]cytisine, [3H]epibatidine, and [125I]alpha-bungarotoxin in eight brain regions. Both replicate HAS lines were more sensitive to nicotine-induced locomotor activity depression than the replicate LAS lines. No consistent HAS/LAS differences were seen on other measures of nicotine sensitivity; however, females were more susceptible to nicotine-induced seizures than males. No HAS/LAS differences in nicotine or cotinine levels were seen, nor were differences seen in the binding of nicotinic ligands. Females had higher levels of plasma cotinine and brain nicotine than males but had lower brain cotinine levels than males. Sensitivity to a specific action of nicotine cosegregates during selective breeding for differential sensitivity to a specific action of ethanol. The differential sensitivity of the HAS/LAS rats is due to differences in central nervous system sensitivity and not to pharmacokinetic differences. The differential central nervous system sensitivity cannot be explained by differences in the numbers of nicotinic receptors labeled in ligand-binding experiments. The apparent genetic correlation between ethanol and nicotine sensitivities suggests that common genes modulate, in part, the actions of both ethanol and nicotine and may explain the frequent coabuse of these agents.

  6. Magnetic and structural properties of Sr0.75La0.25FexCu0.20O19 (10.40≤x≤11.80) hexagonal ferrites prepared by the solid-state reaction

    International Nuclear Information System (INIS)

    Yang, Yujie; Shao, Juxiang; Wang, Fanhou; Liu, Xiansong; Feng, Shuangjiu; Huang, Duohui; Yang, Junsheng; Jin, Chengguo

    2016-01-01

    In this study, the hexaferrite magnetic powders and magnets according to the formula Sr 0.75 La 0.25 Fe x Cu 0.20 O 19 , where x ranging from 10.40 to 11.80 with a step of 0.2 were prepared by the solid-state reaction. X-ray diffraction was performed to investigate the microstructures of the magnetic powders. The results show that a single magnetoplumbite phase is obtained for the magnetic powders with Fe content (10.60≤x≤11.60). For the magnetic powders with Fe content (x) of 10.40 or 11.80, magnetic impurities appear in the structure. A field emission scanning electron microscopy was hired to explore the micrographs of the magnets. The hexaferrite magnets are formed of hexagonal-shaped crystals. A magnetic properties test instrument was used in order to study the magnetic properties of the magnets. The remanence and maximum energy product first increase with Fe content (x) from 10.40 to 11.00 and then begin to decrease when Fe content (x) continues to increase. While the intrinsic coercivity and magnetic induction coercivity first increase with Fe content (x) from 10.40 to 11.20 and then decrease when Fe content (x)>11.20. - Highlights: • The hexaferrite Sr 0.75 La 0.25 Fe x Cu 0.20 O 19 (10.40≤x≤11.80) magnetic powders and magnets were synthesized by the solid-state reaction. • The hexaferrite magnets are formed of hexagonal-shaped crystals. • At Fe content (x)=11.00, B r and (BH) max for the magnets reach the maximum values. At Fe content (x)=11.20, H cj and H cb for the magnets reach the maximum values.

  7. Magnetic effects of interstitial hydrogen in nickel

    Energy Technology Data Exchange (ETDEWEB)

    León, Andrea [Departamento de Física, Universidad Técnica Federico Santa María, Valparaíso (Chile); Velásquez, E.A. [Facultad de Física y Centro de Investigación en Nanotecnología y Materiales Avanzados CIEN-UC, Pontificia Universidad Católica de Chile, Santiago (Chile); Centro para el Desarrollo de la Nanociencia y la Nanotecnología CEDENNA, Santiago (Chile); Grupo de Investigación en Modelamiento y Simulación Computacional, Universidad de San Buenaventura Sec. Medellín, Medellín (Colombia); Mazo-Zuluaga, J. [Grupo de Instrumentación Científica y Microelectrónica, Grupo de Estado Sólido, IF-FCEN, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mejía-López, J. [Facultad de Física y Centro de Investigación en Nanotecnología y Materiales Avanzados CIEN-UC, Pontificia Universidad Católica de Chile, Santiago (Chile); Centro para el Desarrollo de la Nanociencia y la Nanotecnología CEDENNA, Santiago (Chile); Florez, J.M. [Departamento de Física, Universidad Técnica Federico Santa María, Valparaíso (Chile); and others

    2017-01-01

    Hydrogen storage in materials is among the most relevant fields when thinking about energy conversion and storage. In this work we present a study that responds to a couple of questions concerning induced electronic changes that H produces in ferromagnetic nickel (Ni) host. We calculate and explain the change of magnetic properties of Ni with different concentrations of H. Density functional theory calculations (DFT) were performed for super-cells of fcc Ni with interstitial H in octahedral sites at different concentrations. In order to physically explain the effect of magnetization diminishing as the hydrogen concentration increases, we propose a simple Stoner type of model to describe the influence of the H impurity on the magnetic properties of Ni. The exchange splitting reduction, as shown in first principles calculations, is clearly explained within this physical model. Using a paramagnetic Ni fcc band with variable number of electrons and a Stoner model allow us to obtain the correct trend for the magnetic moment of the system as a function of the H concentration. - Highlights: • We calculate and explain the change of magnetic properties of Ni with different concentrations of H. • We propose a simple Stoner type of model to describe the influence of the H impurity on the magnetic properties of Ni. • The band exchange splitting reduction as the H concentration increases, is a consequence of the competition between the band energy term (kinetic energy) and the ferromagnetic energy term (Weiss field).

  8. Magnetic susceptibility measurement using 2D magnetic resonance imaging

    Czech Academy of Sciences Publication Activity Database

    Marcon, P.; Bartušek, Karel; Burdkova, M.; Dokoupil, Zdeněk

    2011-01-01

    Roč. 22, č. 10 (2011), 105702:1-8 ISSN 0957-0233 R&D Projects: GA ČR GAP102/11/0318; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : magnetic flux density * magnetic susceptibility * MRI * MR signal * reaction field Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.494, year: 2011

  9. Temporal viscosity modulations driven by a pH sensitive polymer coupled to a pH-changing chemical reaction.

    Science.gov (United States)

    Escala, D M; Muñuzuri, A P; De Wit, A; Carballido-Landeira, J

    2017-05-17

    The Formaldehyde-Sulfite (FS) and the Formaldehyde-Sulfite-Gluconolactone (FSG) systems are examples of complex chemical reactions accompanied by well-controlled variations in pH. While the FS system exhibits a clock behavior, in the FSG reaction, this mechanism is coupled with the hydrolysis of the gluconolactone which gives the possibility to show large temporal oscillations of pH in an open reactor. In this work, we show how these reactive systems, due to their organic nature, can be coupled with pH sensitive polymers, particularly with polyacrylic acid (PAA) to trigger temporal changes of viscosity. We characterize this coupled reactive system showing the effects of changes in the initial concentrations of the polymer and in the chemical reagents on the induction time, the magnitude of the pH variations and the temporal modifications of the viscosity.

  10. Stretchable Spin Valve with Stable Magnetic Field Sensitivity by Ribbon-Patterned Periodic Wrinkles.

    Science.gov (United States)

    Li, Huihui; Zhan, Qingfeng; Liu, Yiwei; Liu, Luping; Yang, Huali; Zuo, Zhenghu; Shang, Tian; Wang, Baomin; Li, Run-Wei

    2016-04-26

    A strain-relief structure by combining the strain-engineered periodic wrinkles and the parallel ribbons was employed to fabricate flexible dual spin valves onto PDMS substrates in a direct sputtering method. The strain-relief structure can accommodate the biaxial strain accompanying with stretching operation (the uniaxial applied tensile strain and the induced transverse compressive strain due to the Poisson effect), thus significantly reducing the influence of the residual strain on the giant magnetoresistance (GMR) performance. The fabricated GMR dual spin-valve sensor exhibits the nearly unchanged MR ratio of 9.9%, magnetic field sensitivity up to 0.69%/Oe, and zero-field resistance in a wide range of stretching strain, making it promising for applications on a conformal shape or a movement part.

  11. The history of permanent magnet materials

    International Nuclear Information System (INIS)

    Livingston, J.D.

    1990-01-01

    Permanent-magnet materials play a large and growing, but largely unseen, role in today's technology. Many common devices in the home and elsewhere, including appliances, computers and printers, contain permanent-magnet motors and actuators. The growth of applications for permanent magnets results in large part from the improvements in magnetic properties, which allow the engineer to design smaller, lighter and more efficient devices. The properties of the greatest technological interest are remanence, coercivity and maximum energy product. All are non-equilibrium and high structure-sensitive. Coercivity is particularly sensitive to microstructure, while remanence is sensitive to texture (crystallographic alignment). The energy product depends on both coercivity and remanence. The more than one hundredfold increase in the available energy product in this century, and the corresponding amount of magnet required for a specific application, are shown

  12. Lectures on magnetism and neutron scattering

    International Nuclear Information System (INIS)

    Gunn, J.M.F.

    1983-12-01

    The paper contains six lectures given to the Neutron Division of the Rutherford Appleton laboratory in 1983. The aim was to explain fundamental physics of neutron scattering and basic magnetism to the non-specialist scientist. The text includes: origin of neutron's magnetic moment and spin-dependent interactions with electrons and nuclei, why are solids magnetic, magnetic anistropy and domain structure, phenomenological spin waves, magnetic phase transitions and electronic excitations in magnets. (U.K.)

  13. Quadrupole-octupole coupled states in 112Cd populated in the 111Cd(d ⃗,p ) reaction

    Science.gov (United States)

    Jamieson, D. S.; Garrett, P. E.; Bildstein, V.; Demand, G. A.; Finlay, P.; Green, K. L.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Ball, G. C.; Faestermann, T.; Hertenberger, R.; Wirth, H.-F.

    2014-11-01

    States in 112Cd have been studied with the 111Cd(d ⃗,p ) 12Cd reaction using 22 MeV polarized deuterons. The protons from the reaction were momentum analyzed with a Q3D magnetic spectrograph, and spectra have been recorded with a position-sensitive detector located on the focal plane. Angular distributions of cross sections and analyzing powers have been constructed for the low-lying negative-parity states observed, including the 3-,4-, and 5- members of the previously assigned quadrupole-octupole quintuplet. The 5- member at 2373-keV possess the second largest spectroscopic strength observed, and is reassigned as having the s1/2⊗h11/2 two-quasineutron configuration as the dominate component of its wave function.

  14. A kinetic model to explain the grain size and organic matter content dependence of magnetic susceptibility in transitional marine environments: A case study in Ria de Muros (NW Iberia)

    Science.gov (United States)

    Mohamed, Kais J.; Andrade, Alba; Rey, Daniel; Rubio, Belén.; Bernabeu, Ana María.

    2017-06-01

    Magnetic minerals in marine sediments are sensitive indicators of processes such as provenance changes, climatic controls, pollution, and postdepositional geochemical changes. Magnetic susceptibility is the bulk property of the sediments most commonly used to understand the magnetic characteristics of sediments. Before conclusions can be drawn from changes in this parameter, it is important to understand what factors and to what extent control changes in magnetic susceptibility. The magnetic susceptibility of surficial sediments in the Galician Rias Baixas, in NW Spain, has been shown to covary with sediment texture and organic matter content. Downcore, the magnetic properties of these sediments experience drastic changes as a result of strong dissolution caused by early diagenesis. In this paper, we further explore the relationship between these factors and formalize the observed covariations as the result of a simple second-order kinetic model dependent on the content of organic matter in surficial sediments in the Ria de Muros. The reanalysis of previously reported data from the Rias de Vigo and Pontevedra confirmed the validity of this model and suggested further controls such as wave climate and water depth in the rates at which magnetic susceptibility changes are controlled by organic matter content.

  15. Chelating capture and magnetic removal of non-magnetic heavy metal substances from soil

    Science.gov (United States)

    Fan, Liren; Song, Jiqing; Bai, Wenbo; Wang, Shengping; Zeng, Ming; Li, Xiaoming; Zhou, Yang; Li, Haifeng; Lu, Haiwei

    2016-02-01

    A soil remediation method based on magnetic beneficiation is reported. A new magnetic solid chelator powder, FS@IDA (core-shell Fe3O4@SiO2 nanoparticles coated with iminodiacetic acid chelators), was used as a reactive magnetic carrier to selectively capture non-magnetic heavy metals in soil by chelation and removal by magnetic separation. FS@IDA was prepared via inorganic-organic and organic synthesis reactions that generated chelating groups on the surface of magnetic, multi-core, core-shell Fe3O4@SiO2 (FS) nanoparticles. These reactions used a silane coupling agent and sodium chloroacetate. The results show that FS@IDA could chelate the heavy metal component of Cd, Zn, Pb, Cu and Ni carbonates, lead sulfate and lead chloride in water-insoluble salt systems. The resulting FS@IDA-Cd and FS@IDA-Pb chelates could be magnetically separated, resulting in removal rates of approximately 84.9% and 72.2% for Cd and Pb, respectively. FS@IDA could not remove the residual heavy metals and those bound to organic matter in the soil. FS@IDA did not significantly alter the chemical composition of the soil, and it allowed for fast chelating capture, simple magnetic separation and facilitated heavy metal elution. FS@IDA could also be easily prepared and reprocessed.

  16. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    Science.gov (United States)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using random forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers were 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the ScoreCard database of possible skin or sense organ toxicants as primary candidates for experimental validation. PMID:25560674

  17. Neuro-genetic system for optimization of GMI samples sensitivity.

    Science.gov (United States)

    Pitta Botelho, A C O; Vellasco, M M B R; Hall Barbosa, C R; Costa Silva, E

    2016-03-01

    Magnetic sensors are largely used in several engineering areas. Among them, magnetic sensors based on the Giant Magnetoimpedance (GMI) effect are a new family of magnetic sensing devices that have a huge potential for applications involving measurements of ultra-weak magnetic fields. The sensitivity of magnetometers is directly associated with the sensitivity of their sensing elements. The GMI effect is characterized by a large variation of the impedance (magnitude and phase) of a ferromagnetic sample, when subjected to a magnetic field. Recent studies have shown that phase-based GMI magnetometers have the potential to increase the sensitivity by about 100 times. The sensitivity of GMI samples depends on several parameters, such as sample length, external magnetic field, DC level and frequency of the excitation current. However, this dependency is yet to be sufficiently well-modeled in quantitative terms. So, the search for the set of parameters that optimizes the samples sensitivity is usually empirical and very time consuming. This paper deals with this problem by proposing a new neuro-genetic system aimed at maximizing the impedance phase sensitivity of GMI samples. A Multi-Layer Perceptron (MLP) Neural Network is used to model the impedance phase and a Genetic Algorithm uses the information provided by the neural network to determine which set of parameters maximizes the impedance phase sensitivity. The results obtained with a data set composed of four different GMI sample lengths demonstrate that the neuro-genetic system is able to correctly and automatically determine the set of conditioning parameters responsible for maximizing their phase sensitivities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The influence of bias magnetization of nanoparticles on GMR sensor signal and sensitivity for the ultra-low concentration detection

    Science.gov (United States)

    Zhang, Yang; Xu, Jie; Cao, Derang; Li, Qiang; Zhao, Guoxia; Sun, Nian X.; Li, Shandong

    2018-05-01

    In the broad research of the GMR bio-sensing technology, it is vital to explore appropriate magnetic labels and its influences on the detection signal. In this work, four kinds of ferrite particles of γ-Fe2O3, CoFe2O4, NiFe2O4 and NiZnFe2O4 were prepared through calcining the Dimethyl Formamide (DMF) solution of the transition metal nitrates [Fe(NO3)3 and X(NO3)2, X = Co, Ni, Zn] to study the effect of magnetic properties on detection signals using a DC in-plane measuring method. It was revealed that for four particles, the output voltage differences |ΔV| between with and without magnetic particles exhibit log-linear functions of the particles concentrations x in the range from 0.1 to 10 ng/mL. A very low limitation of detection (LOD) of 0.1 ng/mL for all the samples was obtained, which is two orders smaller than that in the previous work. Moreover, the change of output voltage difference at the LOD (|ΔVlim|) is proportional to the magnetization at bias field (bias magnetization, Mbias), which indicates that larger Mbias leads to a lower LOD. This work provides a useful guidance in selecting or preparing magnetic labels to enhance the sensitivity of GMR biosensors.

  19. Magnetic Field Effect: An Efficient Tool To Investigate The Mechanism Of Reactions Using Laser Flash Photolysis Technique

    International Nuclear Information System (INIS)

    Basu, Samita; Bose, Adity; Dey, Debarati

    2008-01-01

    Magnetic field effect combined with laser flash photolysis technique have been used to study the mechanism of interactions between two drug-like quinone molecules, Menadione (1,4-naphthoquinone, MQ) and 9, 10 Anthraquinone (AQ) with one of the DNA bases, Adenine in homogeneous acetonitrile/water and heterogeneous micellar media. A switchover in reaction mode from electron transfer to hydrogen abstraction is observed with MQ on changing the solvent from acetonitrile/water to micelle; whereas, AQ retains its mode of interaction towards Adenine as electron transfer in both the media due to its bulky structure compared to MQ

  20. Spectrometer sensitivity calibration in the extreme uv by means of branching ratios of magnetic dipole lines

    International Nuclear Information System (INIS)

    Denne, B.; Hinnov, E.

    1984-04-01

    Relative intensity measurements of various line pairs resulting from magnetic dipole transitions within the configurations s 2 p 2 and s 2 p 4 , in conjunction with calculated transition probabilities, have been used to determine the wavelength dependence of the sensitivity of a grazing incidence spectrometer, in the range 400 to 1000 A. Emissions from Cr XIX, Fe XXI, Ni XXI and XXIII, Cu XXIV, and Zr XXVII ions in PLT tokamak discharges were used for this purpose. Absolute sensitivity of the spectrometer at selected wavelengths had been determined by the traditional hydrogen, helium, carbon, and oxygen electric-dipole line pairs from the same discharges. Similar attempts to use transitions in the s 2 p 3 configurations in Cr XVIII, Zr XXVI, and Mo XXVIII ions resulted in significant discrepancies that are ascribed to uncertainties in the corresponding calculated transition probabilities

  1. Magnetic monopoles

    International Nuclear Information System (INIS)

    Preskill, J

    1984-01-01

    This article offers a review of the physics of the magnetic monopole, which, although as yet unseen, offers sound theoretical reasons to believe that it must exist. Several theories are presented and equations are given. The idea that magnetic monopoles, stable particles carrying magnetic charges, ought to exist has, according to the authors, proved to be very durable. One theory presented demonstrates the consistency of magnetic monopoles with quantum electrodynamics. Another theory demonstrates the necessity of monopoles in grand unified gauge theories. The authors believe it is reasonable to expect the monopole to be an extremely heavy stable elementary particle. The stability of the classical monopole solution given is ensured by a topological principle explained

  2. Development of a polymerase chain reaction applicable to rapid and sensitive detection of Clonorchis sinensis eggs in human stool samples

    Science.gov (United States)

    Cho, Pyo Yun; Na, Byoung-Kuk; Mi Choi, Kyung; Kim, Jin Su; Cho, Shin-Hyeong; Lee, Won-Ja; Lim, Sung-Bin; Cha, Seok Ho; Park, Yun-Kyu; Pak, Jhang Ho; Lee, Hyeong-Woo; Hong, Sung-Jong; Kim, Tong-Soo

    2013-01-01

    Microscopic examination of eggs of parasitic helminths in stool samples has been the most widely used classical diagnostic method for infections, but tiny and low numbers of eggs in stool samples often hamper diagnosis of helminthic infections with classical microscopic examination. Moreover, it is also difficult to differentiate parasite eggs by the classical method, if they have similar morphological characteristics. In this study, we developed a rapid and sensitive polymerase chain reaction (PCR)-based molecular diagnostic method for detection of Clonorchis sinensis eggs in stool samples. Nine primers were designed based on the long-terminal repeat (LTR) of C. sinensis retrotransposon1 (CsRn1) gene, and seven PCR primer sets were paired. Polymerase chain reaction with each primer pair produced specific amplicons for C. sinensis, but not for other trematodes including Metagonimus yokogawai and Paragonimus westermani. Particularly, three primer sets were able to detect 10 C. sinensis eggs and were applicable to amplify specific amplicons from DNA samples purified from stool of C. sinensis-infected patients. This PCR method could be useful for diagnosis of C. sinensis infections in human stool samples with a high level of specificity and sensitivity. PMID:23916334

  3. Electron spin relaxation can enhance the performance of a cryptochrome-based magnetic compass sensor

    DEFF Research Database (Denmark)

    Kattnig, Daniel R; Sowa, Jakub K; Solov'yov, Ilia A

    2016-01-01

    thaliana cryptochrome 1 were obtained from molecular dynamics (MD) simulations and used to calculate the spin relaxation caused by modulation of the exchange and dipolar interactions. We find that intermediate spin relaxation rates afford substantial enhancements in the sensitivity of the reaction yields....... Here we argue that certain spin relaxation mechanisms can enhance its performance. We focus on the flavin-tryptophan radical pair in cryptochrome, currently the only candidate magnetoreceptor molecule. Correlation functions for fluctuations in the distance between the two radicals in Arabidopsis...... to an Earth-strength magnetic field. Supported by calculations using toy radical pair models, we argue that these enhancements could be consistent with the molecular dynamics and magnetic interactions in avian cryptochromes....

  4. Estimation of parameter sensitivities for stochastic reaction networks

    KAUST Repository

    Gupta, Ankit

    2016-01-01

    Quantification of the effects of parameter uncertainty is an important and challenging problem in Systems Biology. We consider this problem in the context of stochastic models of biochemical reaction networks where the dynamics is described as a

  5. Manipulating Neutral Atoms in Chip-Based Magnetic Traps

    Science.gov (United States)

    Aveline, David; Thompson, Robert; Lundblad, Nathan; Maleki, Lute; Yu, Nan; Kohel, James

    2009-01-01

    Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.

  6. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  7. Magnetically Coupled Calorimeters

    Science.gov (United States)

    Bandler, Simon

    2011-01-01

    Calorimeters that utilize the temperature sensitivity of magnetism have been under development for over 20 years. They have targeted a variety of different applications that require very high resolution spectroscopy. I will describe the properties of this sensor technology that distinguish it from other low temperature detectors and emphasize the types of application to which they appear best suited. I will review what has been learned so far about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. I will introduce some of the applications where magnetic calorimeters are being used and also where they are in development for future experiments. So far, most magnetic calorimeter research has concentrated on the use of paramagnets to provide temperature sensitivity; recent studies have also focused on magnetically coupled calorimeters that utilize the diamagnetic response of superconductors. I will present some of the highlights of this research, and contrast the properties of the two magnetically coupled calorimeter types.

  8. Biological cell as a soft magnetoelectric material: Elucidating the physical mechanisms underpinning the detection of magnetic fields by animals

    Science.gov (United States)

    Krichen, S.; Liu, L.; Sharma, P.

    2017-10-01

    Sharks, birds, bats, turtles, and many other animals can detect magnetic fields. Aside from using this remarkable ability to exploit the terrestrial magnetic field map to sense direction, a subset is also able to implement a version of the so-called geophysical positioning system. How do these animals detect magnetic fields? The answer to this rather deceptively simple question has proven to be quite elusive. The currently prevalent theories, while providing interesting insights, fall short of explaining several aspects of magnetoreception. For example, minute magnetic particles have been detected in magnetically sensitive animals. However, how is the detected magnetic field converted into electrical signals given any lack of experimental evidence for relevant electroreceptors? In principle, a magnetoelectric material is capable of converting magnetic signals into electricity (and vice versa). This property, however, is rare and restricted to a rather small set of exotic hard crystalline materials. Indeed, such elements have never been detected in the animals studied so far. In this work we quantitatively outline the conditions under which a biological cell may detect a magnetic field and convert it into electrical signals detectable by biological cells. Specifically, we prove the existence of an overlooked strain-mediated mechanism and show that most biological cells can act as nontrivial magnetoelectric materials provided that the magnetic permeability constant is only slightly more than that of a vacuum. The enhanced magnetic permeability is easily achieved by small amounts of magnetic particles that have been experimentally detected in magnetosensitive animals. Our proposed mechanism appears to explain most of the experimental observations related to the physical basis of magnetoreception.

  9. Multitarget global sensitivity analysis of n-butanol combustion.

    Science.gov (United States)

    Zhou, Dingyu D Y; Davis, Michael J; Skodje, Rex T

    2013-05-02

    A model for the combustion of butanol is studied using a recently developed theoretical method for the systematic improvement of the kinetic mechanism. The butanol mechanism includes 1446 reactions, and we demonstrate that it is straightforward and computationally feasible to implement a full global sensitivity analysis incorporating all the reactions. In addition, we extend our previous analysis of ignition-delay targets to include species targets. The combination of species and ignition targets leads to multitarget global sensitivity analysis, which allows for a more complete mechanism validation procedure than we previously implemented. The inclusion of species sensitivity analysis allows for a direct comparison between reaction pathway analysis and global sensitivity analysis.

  10. Ultrafast magnetization dynamics in diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Morandi, O [INRIA Nancy Grand-Est and Institut de Recherche en Mathematiques Avancees, 7 rue Rene Descartes, F-67084 Strasbourg (France); Hervieux, P-A; Manfredi, G [Institut de Physique et Chimie des Materiaux de Strasbourg, 23 rue du Loess, F-67037 Strasbourg (France)], E-mail: morandi@dipmat.univpm.it

    2009-07-15

    We present a dynamical model that successfully explains the observed time evolution of the magnetization in diluted magnetic semiconductor quantum wells after weak laser excitation. Based on the pseudo-fermion formalism and a second-order many-particle expansion of the exact p-d exchange interaction, our approach goes beyond the usual mean-field approximation. It includes both the sub-picosecond demagnetization dynamics and the slower relaxation processes that restore the initial ferromagnetic order in a nanosecond timescale. In agreement with experimental results, our numerical simulations show that, depending on the value of the initial lattice temperature, a subsequent enhancement of the total magnetization may be observed within the timescale of a few hundred picoseconds.

  11. The 'Big Karl' magnetic spectrometer - studies of the 103Ru transition nucleus with (d,p) and (p,d) reactions

    International Nuclear Information System (INIS)

    Huerlimann, W.

    1981-04-01

    The paper describes the structure and characteristics of the spectrometer and its application in a study of the 102 Ru(d,p) 103 Ru and 104 Ru(p,d) 103 Ru reactions. The study is structured as follows: To begin with the theoretical fundamentals, ion-optical characteristics and layout of BIG KARL are described. Field measurements and analyses carried out on the magnets of the spectrometer are described as well as the functioning of the 'Ht correction coils' used here for the first time to prevent faulty imaging. Chapter IV then describes methods employed so far to optimize resolution for large aperture angles of the spectrometer. Finally, chapter V investigates the 103 Ru transition nucleons on the basis of the 102 Ru(d,p) 103 RU and 104 Ru(p,d) 103 Ru transfer reactions measured in BIG KARL. (orig./HSI) [de

  12. Iron Oxide-Supported Copper Oxide Nanoparticles (Nanocat-Fe-CuO): Magnetically Recyclable Catalysts for the Synthesis of Pyrazole Derivatives, 4-Methoxyaniline, and Ullmann-type Condensation Reactions

    Science.gov (United States)

    An efficient and benign protocol is reported for the synthesis of 4-methoxyaniline, medicinally important pyrazole derivatives, and Ullmann-type condensation reaction using magnetically separable and reusable magnetite-supported copper (nanocat-Fe-CuO) nanoparticles under mild co...

  13. Life on magnets: stem cell networking on micro-magnet arrays.

    Science.gov (United States)

    Zablotskii, Vitalii; Dejneka, Alexandr; Kubinová, Šárka; Le-Roy, Damien; Dumas-Bouchiat, Frédéric; Givord, Dominique; Dempsey, Nora M; Syková, Eva

    2013-01-01

    Interactions between a micro-magnet array and living cells may guide the establishment of cell networks due to the cellular response to a magnetic field. To manipulate mesenchymal stem cells free of magnetic nanoparticles by a high magnetic field gradient, we used high quality micro-patterned NdFeB films around which the stray field's value and direction drastically change across the cell body. Such micro-magnet arrays coated with parylene produce high magnetic field gradients that affect the cells in two main ways: i) causing cell migration and adherence to a covered magnetic surface and ii) elongating the cells in the directions parallel to the edges of the micro-magnet. To explain these effects, three putative mechanisms that incorporate both physical and biological factors influencing the cells are suggested. It is shown that the static high magnetic field gradient generated by the micro-magnet arrays are capable of assisting cell migration to those areas with the strongest magnetic field gradient, thereby allowing the build up of tunable interconnected stem cell networks, which is an elegant route for tissue engineering and regenerative medicine.

  14. Zero-magnetic field effect in pathogen bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, D.E. E-mail: Dorina.Creanga@email.romdor@uaic.ro; Poiata, A.; Morariu, V.V. E-mail: vvm@140.itim-cj.ro; Tupu, P

    2004-05-01

    Two lots of Gram-negative bacterial strains were tested for antibiotic drug resistance after exposure to zero-magnetic field. We found that the magneto-sensitive strains represent half of the analyzed samples (three Pseudomonas and five Enterobacter strains), some of them presenting two-three times modified resistance to antibiotic, while others revealed eight or 16 times changed resistance. Pseudomonas strain magnetic sensitivity is revealed better by ampicillin and tetracycline, while Enterobacter strain magnetic sensitivity is revealed better by ampicillin, kanamycin and ofloxacin.

  15. Zero-magnetic field effect in pathogen bacteria

    International Nuclear Information System (INIS)

    Creanga, D.E.; Poiata, A.; Morariu, V.V.; Tupu, P.

    2004-01-01

    Two lots of Gram-negative bacterial strains were tested for antibiotic drug resistance after exposure to zero-magnetic field. We found that the magneto-sensitive strains represent half of the analyzed samples (three Pseudomonas and five Enterobacter strains), some of them presenting two-three times modified resistance to antibiotic, while others revealed eight or 16 times changed resistance. Pseudomonas strain magnetic sensitivity is revealed better by ampicillin and tetracycline, while Enterobacter strain magnetic sensitivity is revealed better by ampicillin, kanamycin and ofloxacin

  16. High sensitivity tracer imaging of iron oxides using magnetic particle imaging

    International Nuclear Information System (INIS)

    Goodwill, Patrick; Konkle, Justin; Lu, Kuan; Zheng, Bo; Conolly, Steven

    2014-01-01

    Full text: Magnetic Particle Imaging (MPI) is a new tracer imaging modality that is gaining significant interest from NMR and MRI researchers. While the physics of MPI differ substantially from MRI, it employs hardware and imaging concepts that are familiar to MRI researchers, such as magnetic excitation and detection, pulse sequences, and relaxation effects. Furthermore, MPI employs the same superparamagnetic iron oxide (SPIO) contrast agents that are sometimes used for MR angiography and are often used for MRI cell tracking studies. These SPIOs are much safer for humans than iodine or gadolinium, especially for Chronic Kidney Disease (CKD) patients. The weak kidneys of CKD patients cannot safely excrete iodine or gadolinium, leading to increased morbidity and mortality after iodinated X-ray or CT angiograms, or after gadolinium-MRA studies. Iron oxides, on the other hand, are processed in the liver, and have been shown to be safe even for CKD patients. Unlike the 'black blood' contrast generated by SPIOs in MRI due to increased T2 dephasing, SPIOs in MPI generate positive, 'bright blood' contrast. With this ideal contrast, even prototype MPI scanners can already achieve fast, high-sensitivity, and high-contrast angiograms with millimeter-scale resolutions in phantoms and in animals. Moreover, MPI shows great potential for an exciting array of applications, including stem cell tracking in vivo, first-pass contrast studies to diagnose or stage cancer, and inflammation imaging in vivo. So far, only a handful of prototype small-animal MPI scanners have been constructed worldwide. Hence, MPI is open to great advances, especially in hardware, pulse sequence, and nanoparticle improvements, with the potential to revolutionize the biomedical imaging field. (author)

  17. High sensitivity tracer imaging of iron oxides using magnetic particle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goodwill, Patrick [University of California, Dept. of Bioengineering, Berkeley, CA (United States); Konkle, Justin; Lu, Kuan; Zheng, Bo [UC Berkeley (UCSF), Joint Graduate Group in Bioengineering, CA (United States); Conolly, Steven [University of California, Berkeley Bioengineering, Electrical Engineering, and Computer Science, CA (United States)

    2014-07-01

    Full text: Magnetic Particle Imaging (MPI) is a new tracer imaging modality that is gaining significant interest from NMR and MRI researchers. While the physics of MPI differ substantially from MRI, it employs hardware and imaging concepts that are familiar to MRI researchers, such as magnetic excitation and detection, pulse sequences, and relaxation effects. Furthermore, MPI employs the same superparamagnetic iron oxide (SPIO) contrast agents that are sometimes used for MR angiography and are often used for MRI cell tracking studies. These SPIOs are much safer for humans than iodine or gadolinium, especially for Chronic Kidney Disease (CKD) patients. The weak kidneys of CKD patients cannot safely excrete iodine or gadolinium, leading to increased morbidity and mortality after iodinated X-ray or CT angiograms, or after gadolinium-MRA studies. Iron oxides, on the other hand, are processed in the liver, and have been shown to be safe even for CKD patients. Unlike the 'black blood' contrast generated by SPIOs in MRI due to increased T2 dephasing, SPIOs in MPI generate positive, 'bright blood' contrast. With this ideal contrast, even prototype MPI scanners can already achieve fast, high-sensitivity, and high-contrast angiograms with millimeter-scale resolutions in phantoms and in animals. Moreover, MPI shows great potential for an exciting array of applications, including stem cell tracking in vivo, first-pass contrast studies to diagnose or stage cancer, and inflammation imaging in vivo. So far, only a handful of prototype small-animal MPI scanners have been constructed worldwide. Hence, MPI is open to great advances, especially in hardware, pulse sequence, and nanoparticle improvements, with the potential to revolutionize the biomedical imaging field. (author)

  18. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Vinicius M. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Muratov, Eugene [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Laboratory of Theoretical Chemistry, A.V. Bogatsky Physical-Chemical Institute NAS of Ukraine, Odessa 65080 (Ukraine); Fourches, Denis [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Strickland, Judy; Kleinstreuer, Nicole [ILS/Contractor Supporting the NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM), P.O. Box 13501, Research Triangle Park, NC 27709 (United States); Andrade, Carolina H. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Tropsha, Alexander, E-mail: alex_tropsha@unc.edu [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States)

    2015-04-15

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative

  19. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    International Nuclear Information System (INIS)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative

  20. Experimental and numerical reaction analysis on sodium-water chemical reaction field

    International Nuclear Information System (INIS)

    Deguchi, Yoshihiro; Takata, Takashi; Yamaguchi, Akira; Kikuchi, Shin; Ohshima, Hiroyuki

    2015-01-01

    In a sodium-cooled fast reactor (SFR), liquid sodium is used as a heat transfer fluid because of its excellent heat transport capability. On the other hand, it has strong chemical reactivity with water vapor. One of the design basis accidents of the SFR is the water leakage into the liquid sodium flow by a breach of heat transfer tubes. This process ends up damages on the heat transport equipment in the SFR. Therefore, the study on sodium-water chemical reactions is of paramount importance for security reasons. This study aims to clarify the sodium-water reaction mechanisms using an elementary reaction analysis. A quasi one-dimensional flame model is applied to a sodium-water counter-flow reaction field. The analysis contains 25 elementary reactions, which consist of 17 H_2-O_2 and 8 Na-H_2O reactions. Temperature and species concentrations in the counter-flow reaction field were measured using laser diagnostics such as LIF and CARS. The main reaction in the experimental conditions is Na+H_2O → NaOH+H and OH is produced by H_2O+H → H_2+OH. It is demonstrated that the reaction model in this study well explains the structure of the sodium-water counter-flow diffusion flame. (author)

  1. ERO modeling and sensitivity analysis of locally enhanced beryllium erosion by magnetically connected antennas

    Science.gov (United States)

    Lasa, A.; Borodin, D.; Canik, J. M.; Klepper, C. C.; Groth, M.; Kirschner, A.; Airila, M. I.; Borodkina, I.; Ding, R.; Contributors, JET

    2018-01-01

    Experiments at JET showed locally enhanced, asymmetric beryllium (Be) erosion at outer wall limiters when magnetically connected ICRH antennas were in operation. A first modeling effort using the 3D erosion and scrape-off layer impurity transport modeling code ERO reproduced qualitatively the experimental outcome. However, local plasma parameters—in particular when 3D distributions are of interest—can be difficult to determine from available diagnostics and so erosion / impurity transport modeling input relies on output from other codes and simplified models, increasing uncertainties in the outcome. In the present contribution, we introduce and evaluate the impact of improved models and parameters with largest uncertainties of processes that impact impurity production and transport across the scrape-off layer, when simulated in ERO: (i) the magnetic geometry has been revised, for affecting the separatrix position (located 50-60 mm away from limiter surface) and thus the background plasma profiles; (ii) connection lengths between components, which lead to shadowing of ion fluxes, are also affected by the magnetic configuration; (iii) anomalous transport of ionized impurities, defined by the perpendicular diffusion coefficient, has been revisited; (iv) erosion yields that account for energy and angular distributions of background plasma ions under the present enhanced sheath potential and oblique magnetic field, have been introduced; (v) the effect of additional erosion sources, such as charge-exchange neutral fluxes, which are dominant in recessed areas like antennas, has been evaluated; (vi) chemically assisted release of Be in molecular form has been included. Sensitivity analysis highlights a qualitative effect (i.e. change in emission patterns) of magnetic shadowing, anomalous diffusion, and inclusion of neutral fluxes and molecular release of Be. The separatrix location, and energy and angular distribution of background plasma fluxes impact erosion

  2. Magnetic studies in evaporated Ni/Pd multilayers

    International Nuclear Information System (INIS)

    Chafai, K.; Salhi, H.; Lassri, H.; Yamkane, Z.; Lassri, M.; Abid, M.; Hlil, E.K.; Krishnan, R.

    2011-01-01

    The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. The Ni thickness dependence of the magnetization and magnetic anisotropy is discussed. The temperature dependence of the spontaneous magnetization is well described by a T 3/2 law in all multilayers. A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization, and the approximate values for the exchange interactions for various Ni layer thicknesses have been obtained. - Research highlights: → The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. → The temperature dependence of the spontaneous magnetization is well described by a T 3/2 law in Ni/Pd multilayers. → The spin-wave constant B was observed to depend on t Ni nonmonotonically. → A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization. → The approximate values for the exchange interactions for various Ni layer thicknesses have been obtained.

  3. Magnetic Structure of Erbium

    DEFF Research Database (Denmark)

    Gibbs, D.; Bohr, Jakob; Axe, J. D.

    1986-01-01

    We present a synchrotron x-ray scattering study of the magnetic phases of erbium. In addition to the magnetic scattering located at the fundamental wave vector τm we also observe scattering from magnetoelastically induced charge modulations at the fundamental wave vector, at twice the fundamental......, and at positions split symmetrically about the fundamental. As the temperature is lowered below 52 K the charge and magnetic scattering display a sequence of lock-in transitions to rational wave vectors. A spin-slip description of the magnetic structure is presented which explains the wave vectors...

  4. A magnetically coupled quench detector for superconducting magnets

    International Nuclear Information System (INIS)

    Jaskierny, W.; Kristalinski, A.; Visser, A.T.

    1993-12-01

    This note describes a low voltage signal detector that is useful for detecting quenches or excessive lead voltages at superconducting magnets. It can also be used for other applications where it is needed to detect low level signals present on high voltage installations. The application of isolated operational amplifiers is often not practical for high voltage applications because of their limited input voltage rating, common mode rejection and sensitivity. The described detector can withstand 7.5 kV input to ground voltage. It has a typical common mode rejection of -150 dB at 60 Hz and an input sensitivity better than 1 mV. The magnetically coupled quench detector assembly is very sensitive to extremely small (order of 1 μAmp) current changes in the sense windings. The detector assembly can therefore also be referred to as a micro current detector

  5. Invariance of the magnetic behavior and AMI in ferromagnetic biphase films with distinct non-magnetic metallic spacers

    Energy Technology Data Exchange (ETDEWEB)

    Silva, E.F. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Gamino, M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Andrade, A.M.H. de [Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Vázquez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Correa, M.A. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Bohn, F., E-mail: felipebohn@fisica.ufrn.br [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)

    2017-02-01

    We investigate the quasi-static magnetic, magnetotransport, and dynamic magnetic properties in ferromagnetic biphase films with distinct non-magnetic metallic spacer layers. We observe that the nature of the non-magnetic metallic spacer material does not have significant influence on the overall biphase magnetic behavior, and, consequently, on the magnetotransport and dynamic magnetic responses. We focus on the magnetoimpedance effect and verify that the films present asymmetric magnetoimpedance effect. Moreover, we explore the possibility of tuning the linear region of the magnetoimpedance curves around zero magnetic field by varying the probe current frequency in order to achieve higher sensitivity values. The invariance of the magnetic behavior and the asymmetric magnetoimpedance effect in ferromagnetic biphase films with distinct non-magnetic metallic spacers place them as promising candidates for probe element and open possibilities to the development of lower-cost high sensitivity linear magnetic field sensor devices.

  6. Evidence for delta-hole components from pion reactions

    International Nuclear Information System (INIS)

    Morris, C.L.

    1982-01-01

    Some anomalies observed in pion-induced reactions have been qualitatively explained with a model which includes Δ 3 3 admixtures in low lying nuclear states. Semi-quantitative analysis of these effects indicates the amplitudes for the Δ 3 3 admixtures necessary to explain these effects are on the order of a few percent. Although a more rigorous theoretical treatment of this problem is necessary, it appears that pion-induced reactions may provide a tool with which the spectroscopy of these Δ 3 3 -admixtures can be studied

  7. Microstructure, magnetic properties and magnetic hardening in 2:17 Sm-Co magnets

    International Nuclear Information System (INIS)

    Tang, W.; Zhang, Y.; Hadjipanayis, G.C.

    2002-01-01

    A comprehensive and systematic study has been made on Sm(Co,Fe,M,L) z magnets (M=Cu or Ni, and L=Zr or Ti) to completely understand the effects of composition and processing on the microstructure and magnetic properties of magnets. Ti-containing magnets do not have a lamellar phase but exhibit only a cellular microstructure, resulting in a much lower coercivity (below 10 kOe). Ni-containing magnets exhibit a perfect cellular/lamellar microstructure, but without a large domain wall energy gradient at the interface of the 2:17 and 1:5 phases, leading to a low coercivity. Only in the magnets containing both Cu and Zr, a uniform and stable cellular/lamellar microstructure with a high domain wall energy gradient across the 1:5 phase is formed, resulting in high coercivity. These results indicate that the conditions for effective magnetic hardening are: (1) Formation of a cellular/lamellar microstructure, and (2) establishment of a domain wall energy gradient at the cell boundaries. Based on all of these experimental results, the magnetization reversal mechanism of 2:17 Sm-Co magnets can be explained by both the domain wall pinning and nucleation models. The nucleation mechanism holds at any temperature in the Cu-rich magnets, and only above the Curie temperature of the 1:5 phase in the alloys with the lower Cu content. In these cases, the 2:17 cells become magnetically decoupled. (orig.)

  8. Magnetic resonance imaging of the brain in congenital cytomegalovirus infection

    International Nuclear Information System (INIS)

    Boesch, C.; Issakainen, J.; Kewitz, G.; Kikinis, R.; Martin, E.; Boltshauser, E.

    1989-01-01

    The children (age 2 months to 8 years) with a congenital cytomegalovirus (CMV) infection were studied by magnetic resonance imaging (MRI) using a 2.35 Tesla magnet. CMV infection was confirmed by serological investigations and virus culture in the neonatal period. Nine children had severe mental retardation and cerebral palsy, 1 patient suffered from microcephaly, ataxia and deafness. The cranial MRI examination showed the following abnormalities (N): Dilated lateral ventricles (10) and subarachnoid space (8), oligo/pacgyria (8), delayed/pathological myelination (7), paraventricular cysts (6), intra-cerebral calcification (1). This lack of sensitivity for calcification is explainable by the basic principles of MRI. The paraventricular cystic lesions were adjacent ot the occipital horns of the lateral ventricles and separated only by a thin membrane. This finding might represent a 'new sign' for congenital CMV infection in MRI examinations, being characteristic but nevertheless nonspecific, like calcification in CT. (orig.)

  9. Highly sensitive polymerase chain reaction-free quantum dot-based quantification of forensic genomic DNA

    International Nuclear Information System (INIS)

    Tak, Yu Kyung; Kim, Won Young; Kim, Min Jung; Han, Eunyoung; Han, Myun Soo; Kim, Jong Jin; Kim, Wook; Lee, Jong Eun; Song, Joon Myong

    2012-01-01

    Highlights: ► Genomic DNA quantification were performed using a quantum dot-labeled Alu sequence. ► This probe provided PCR-free determination of human genomic DNA. ► Qdot-labeled Alu probe-hybridized genomic DNAs had a 2.5-femtogram detection limit. ► Qdot-labeled Alu sequence was used to assess DNA samples for human identification. - Abstract: Forensic DNA samples can degrade easily due to exposure to light and moisture at the crime scene. In addition, the amount of DNA acquired at a criminal site is inherently limited. This limited amount of human DNA has to be quantified accurately after the process of DNA extraction. The accurately quantified extracted genomic DNA is then used as a DNA template in polymerase chain reaction (PCR) amplification for short tandem repeat (STR) human identification. Accordingly, highly sensitive and human-specific quantification of forensic DNA samples is an essential issue in forensic study. In this work, a quantum dot (Qdot)-labeled Alu sequence was developed as a probe to simultaneously satisfy both the high sensitivity and human genome selectivity for quantification of forensic DNA samples. This probe provided PCR-free determination of human genomic DNA and had a 2.5-femtogram detection limit due to the strong emission and photostability of the Qdot. The Qdot-labeled Alu sequence has been used successfully to assess 18 different forensic DNA samples for STR human identification.

  10. Lower Mortality in Magnet Hospitals

    Science.gov (United States)

    McHugh, Matthew D.; Kelly, Lesly A.; Smith, Herbert L.; Wu, Evan S.; Vanak, Jill M.; Aiken, Linda H.

    2014-01-01

    Background Although there is evidence that hospitals recognized for nursing excellence—Magnet hospitals—are successful in attracting and retaining nurses, it is uncertain whether Magnet recognition is associated with better patient outcomes than non-Magnets, and if so why. Objectives To determine whether Magnet hospitals have lower risk-adjusted mortality and failure-to-rescue compared with non-Magnet hospitals, and to determine the most likely explanations. Method and Study Design Analysis of linked patient, nurse, and hospital data on 56 Magnet and 508 non-Magnet hospitals. Logistic regression models were used to estimate differences in the odds of mortality and failure-to-rescue for surgical patients treated in Magnet versus non-Magnet hospitals, and to determine the extent to which differences in outcomes can be explained by nursing after accounting for patient and hospital differences. Results Magnet hospitals had significantly better work environments and higher proportions of nurses with bachelor's degrees and specialty certification. These nursing factors explained much of the Magnet hospital effect on patient outcomes. However, patients treated in Magnet hospitals had 14% lower odds of mortality (odds ratio 0.86; 95% confidence interval, 0.76–0.98; P = 0.02) and 12% lower odds of failure-to-rescue (odds ratio 0.88; 95% confidence interval, 0.77–1.01; P = 0.07) while controlling for nursing factors as well as hospital and patient differences. Conclusions The lower mortality we find in Magnet hospitals is largely attributable to measured nursing characteristics but there is a mortality advantage above and beyond what we could measure. Magnet recognition identifies existing quality and stimulates further positive organizational behavior that improves patient outcomes. PMID:24022082

  11. Magnetic properties of HoVOΛ4 in high magnetic fields

    International Nuclear Information System (INIS)

    Andronenko, S.I.; Bazhan, A.N.; Ioffe, V.A.; Udalov, Yu.P.

    1985-01-01

    Values magnetization and susceptibility of HoVO 4 , Van Vleck paramagnetic are specified in the 4.2-40 K temperature range and magnetic fields up to 50 kOe. Magnetic properties of HoVO 4 are analyzed using a theoretical model in which the interaction of rare earth ions with the crystal- and magnetic fields is considered. A possibility of rare earth ion interaction with the Bsub(1g), Bsub(2g), Asub(1g) symmetry deformations is also considered. It is stated that magnetic properties of HoVO 4 are completely explained within the frames of the crystal field model; the rare earth ion interactions with deformations are insignificant. Anisotropy of magnetization in the (001) plane is determined by the crystal field B 4 4 , B 6 4 constants; the constants being shown to be positive

  12. Mechanism of orientation of stimulating currents in magnetic brain stimulation (abstract)

    Science.gov (United States)

    Ueno, S.; Matsuda, T.

    1991-04-01

    We made a functional map of the human motor cortex related to the hand and foot areas by stimulating the human brain with a focused magnetic pulse. We observed that each functional area in the cortex has an optimum direction for which stimulating currents can produce neural excitation. The present report focuses on the mechanism which is responsible for producing this anisotropic response to brain stimulation. We first obtained a functional map of the brain related to the left ADM (abductor digiti minimi muscles). When the stimulating currents were aligned in the direction from the left to the right hemisphere, clear EMG (electromyographic) responses were obtained only from the left ADM to magnetic stimulation of both hemisphere. When the stimulating currents were aligned in the direction from the right to the left hemisphere, clear EMG signals were obtained only from the right ADM to magnetic stimulation of both hemisphere. The functional maps of the brain were sensitive to changes in the direction of the stimulating currents. To explain the phenomena obtained in the experiments, we developed a model of neural excitation elicited by magnetic stimulation. When eddy currents which are induced by pulsed magnetic fields flow in the direction from soma to the distal part of neural fiber, depolarized area in the distal part are excited, and the membrane excitation propagates along the nerve fiber. In contrast, when the induced currents flow in the direction from the distal part to soma, hyperpolarized parts block or inhibit neural excitation even if the depolarized parts near the soma can be excited. The model explains our observation that the orientation of the induced current vectors reflect both the functional and anatomical organization of the neural fibers in the brain.

  13. Biomedical applications of magnetic particles

    CERN Document Server

    Mefford, Thompson

    2018-01-01

    Magnetic particles are increasingly being used in a wide variety of biomedical applications. Written by a team of internationally respected experts, this book provides an up-to-date authoritative reference for scientists and engineers. The first section presents the fundamentals of the field by explaining the theory of magnetism, describing techniques to synthesize magnetic particles, and detailing methods to characterize magnetic particles. The second section describes biomedical applications, including chemical sensors and cellular actuators, and diagnostic applications such as drug delivery, hyperthermia cancer treatment, and magnetic resonance imaging contrast.

  14. Sensitization and cross-reactions patterns in Danish Compositae-allergic patients

    DEFF Research Database (Denmark)

    Paulsen, E; Andersen, Klaus Ejner; Hausen, B M

    2001-01-01

    ), elecampane (Inula helenium), large yellow ox-eye (Telekia speciosa) and cosmea (Cosmos) were additional important allergenic plants. The 3 last mentioned were picked up by SL mix. Most of the lettuce-sensitized persons were CM-positive. 19% of the occupationally sensitized group were negative to both SL...... and CM, making very aimed patch testing necessary, notably when suspecting rare sensitizers such as Gerbera and star of the veldt (Osteospermum). The significance of the weeds dandelion, dog fennel and ox-eye daisy as sensitizers is not clarified, but they are probably less important than cultivated...

  15. Kiss-induced severe anaphylactic reactions

    Directory of Open Access Journals (Sweden)

    Atanasković-Marković Marina

    2010-01-01

    Full Text Available Introduction. Ingestion is the principal route for food allergens to trigger allergic reaction in atopic persons. However, in some highly sensitive patients severe symptoms may develop upon skin contact and by inhalation. The clinical spectrum ranges from mild facial urticaria and angioedema to life-threatening anaphylactic reactions. Outline of Cases. We describe cases of severe anaphylactic reactions by skin contact, induced by kissing in five children with prior history of severe anaphylaxis caused by food ingestion. These cases were found to have the medical history of IgE mediated food allergy, a very high total and specific serum IgE level and very strong family history of allergy. Conclusion. The presence of tiny particles of food on the kisser's lips was sufficient to trigger an anaphylactic reaction in sensitized children with prior history of severe allergic reaction caused by ingestion of food. Allergic reaction provoked with food allergens by skin contact can be a risk factor for generalized reactions. Therefore, extreme care has to be taken in avoiding kissing allergic children after eating foods to which they are highly allergic. Considering that kissing can be a cause of severe danger for the food allergic patient, such persons should inform their partners about the risk factor for causing their food hypersensitivity.

  16. Reward and Punishment Sensitivity in Children with ADHD: validating the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for Children (SPSRQ-C).

    NARCIS (Netherlands)

    Luman, M.; Van Meel, C.S.; Oosterlaan, J.; Geurts, H.M.

    2012-01-01

    This study validates the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for children (SPSRQ-C), using a Dutch sample of 1234 children between 6-13 years old. Factor analysis determined that a 4-factor and a 5-factor solution were best fitting, explaining 41% and 50% of the

  17. Reward and punishment sensitivity in children with ADHD: validating the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for Children (SPSR-C)

    NARCIS (Netherlands)

    Luman, M.; van Meel, C.S.; Oosterlaan, J.; Geurts, H.M.

    2012-01-01

    This study validates the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for children (SPSRQ-C), using a Dutch sample of 1234 children between 6-13 years old. Factor analysis determined that a 4-factor and a 5-factor solution were best fitting, explaining 41% and 50% of the

  18. Lower neighborhood quality in adolescence predicts higher mesolimbic sensitivity to reward anticipation in adulthood

    Science.gov (United States)

    Gonzalez, Marlen Z.; Allen, Joseph P.; Coan, James A.

    2016-01-01

    Life history theory suggests that adult reward sensitivity should be best explained by childhood, but not current, socioeconomic conditions. In this functional magnetic resonance imaging (fMRI) study, 83 participants from a larger longitudinal sample completed the monetary incentive delay (MID) task in adulthood (~25 years old). Parent-reports of neighborhood quality and parental SES were collected when participants were 13 years of age. Current income level was collected concurrently with scanning. Lower adolescent neighborhood quality, but neither lower current income nor parental SES, was associated with heightened sensitivity to the anticipation of monetary gain in putative mesolimbic reward areas. Lower adolescent neighborhood quality was also associated with heightened sensitivity to the anticipation of monetary loss activation in visuo-motor areas. Lower current income was associated with heightened sensitivity to anticipated loss in occipital areas and the operculum. We tested whether externalizing behaviors in childhood or adulthood could better account for neighborhood quality findings, but they did not. Findings suggest that neighborhood ecology in adolescence is associated with greater neural reward sensitivity in adulthood above the influence of parental SES or current income and not mediated through impulsivity and externalizing behaviors. PMID:27838595

  19. Lower neighborhood quality in adolescence predicts higher mesolimbic sensitivity to reward anticipation in adulthood

    Directory of Open Access Journals (Sweden)

    Marlen Z. Gonzalez

    2016-12-01

    Full Text Available Life history theory suggests that adult reward sensitivity should be best explained by childhood, but not current, socioeconomic conditions. In this functional magnetic resonance imaging (fMRI study, 83 participants from a larger longitudinal sample completed the monetary incentive delay (MID task in adulthood (∼25 years old. Parent-reports of neighborhood quality and parental SES were collected when participants were 13 years of age. Current income level was collected concurrently with scanning. Lower adolescent neighborhood quality, but neither lower current income nor parental SES, was associated with heightened sensitivity to the anticipation of monetary gain in putative mesolimbic reward areas. Lower adolescent neighborhood quality was also associated with heightened sensitivity to the anticipation of monetary loss activation in visuo-motor areas. Lower current income was associated with heightened sensitivity to anticipated loss in occipital areas and the operculum. We tested whether externalizing behaviors in childhood or adulthood could better account for neighborhood quality findings, but they did not. Findings suggest that neighborhood ecology in adolescence is associated with greater neural reward sensitivity in adulthood above the influence of parental SES or current income and not mediated through impulsivity and externalizing behaviors.

  20. Search for Magnetic Monopoles

    CERN Multimedia

    2002-01-01

    This experiment is proposed to investigate the possible production of magnetic monopoles at the ISR. Very different values are in principle possible for the magnetic charge of such objects, and the present experiment intends to cover a range of magnetic charges from g, to 12 g, where g is the classical minimum charge of the Dirac theory, .ce g = 1/2e The detector consists of three double layers of solid track detector, which are only sensitive to highly ionizing particles, such as monopoles should be. The detector is placed directly in the vacuum chamber, to avoid the large energy losses that a monopole would suffer in a solid wall. A solenoidal magnet is placed between the intersection region and the detector and around the detector itself, in order to accelerate monopoles to an energy such that they are able to traverse the successive sensitive layers of the detector. The thickness of the sensitive layers is chosen to avoid confusion with possible background arising from highly ionizing ions. The experiment...

  1. Scaling of the susceptibility vs. magnetic-field sweep rate in Fe8 molecular magnet

    Science.gov (United States)

    Jordi, M.; Hernandez-Mínguez, A.; Hernandez, J. M.; Tejada, J.; Stroobants, S.; Vanacken, J.; Moshchalkov, V. V.

    2004-12-01

    The dependence of the magnetization reversal on the sweep rate of the applied magnetic field has been studied for single crystals of Fe8 magnetic molecules. Our experiments have been conducted at temperatures below 1 K and sweep rates of the magnetic field between 103 T/s to 104 T/s. The systematic shift of the values of the magnetic field at which the magnetization reversal occurs, indicates that this reversal process is not governed by the Landau-Zener transition model. Our data can be explained in terms of the superradiance emission model proposed by Chudnovsky and Garanin (Phys. Rev. Lett. 89 (2002) 157201).

  2. Hard magnetic property and δM(H) plot for sintered NdFeB magnet

    International Nuclear Information System (INIS)

    Gao, R.W.; Zhang, D.H.; Li, W.; Li, X.M.; Zhang, J.C.

    2000-01-01

    The hard magnetic properties and the interactions between the grains for sintered Nd 16 Fe 73 Co 5 B 6 magnets are investigated by using δM(H) plot technique. The results show that the δM(H) plot of NdFeB sintered magnet can explain the effects of the microstructure (size, shape and orientation of the grains) and the intergrain interactions on the hard magnetic properties of the magnet. However, the value of δM(H) is positive when the applied field is not strong enough, which means that the common δM(H) plot theory is not completely consistent with the sintered NdFeB magnet

  3. Calculation and Analysis of Permanent Magnet Eddy Current Loss Fault with Magnet Segmentation

    Directory of Open Access Journals (Sweden)

    Bing Li

    2016-01-01

    Full Text Available This paper investigates the problem of calculating and analyzing the effect of the permanent magnet eddy current loss fault due to magnet segmentation. Taking an interior permanent magnet synchronous motor with inverter supplied as an example, the rated power of motor was 2.2 kW. Three-dimensional finite-element model was firstly established based on finite-element software. Then, the model mesh and boundary conditions were handled specially; permanent magnet eddy current loss fault was calculated and analyzed theoretically with magnet segmentation from space harmonic and time harmonic, respectively. Finally, calculation results were compared and explained. A useful conclusion for permanent magnet synchronous motor design has been obtained.

  4. Magnetic resonance of field-frozen and zero-field-frozen magnetic fluids

    International Nuclear Information System (INIS)

    Pereira, A.R.; Pelegrini, F.; Neto, K. Skeff; Buske, N.; Morais, P.C.

    2004-01-01

    In this study magnetic resonance was used to investigate magnetic fluid samples frozen under zero and non-zero (15 kG) external fields. The magnetite-based sample containing 2x10 17 particle/cm 3 was investigated from 100 to 400 K. Analysis of the temperature dependence of the resonance field revealed bigger magnetic structures in the frozen state than in the liquid phase. Also, differences in the mesoscopic organization in the frozen state may explain the data obtained from samples frozen under zero and non-zero fields

  5. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  6. Biomimetic magnetic nanoparticles

    OpenAIRE

    Klem, Michael T.; Young, Mark; Douglas, Trevor

    2005-01-01

    Magnetic nanoparticles are of considerable interest because of their potential use in high-density memory devices, spintronics, and applications in diagnostic medicine. The conditions for synthesis of these materials are often complicated by their high reaction temperatures, costly reagents, and post-processing requirements. Practical applications of magnetic nanoparticles will require the development of alternate synthetic strategies that can overcome these impediments. Biomimetic approaches...

  7. Magnetic polymer nanocomposites for sensing applications

    KAUST Repository

    Alfadhel, Ahmed

    2014-11-01

    We report the fabrication and characterization of magnetic polymer nanocomposites for a wide range of sensing applications. The composites are made of magnetic nanowires (NWs) incorporated into polymers such as polydimethylsiloxane (PDMS) or UV sensitive SU-S. The developed composites utilize the permanent magnetic behavior of the NWs, allowing remote operation without an additional magnetic field to magnetize the NWs, which simplifies miniaturization and integration in microsystems. In addition, the nanocomposite benefits from the easy patterning of the polymer leading to a corrosion resistant, highly elastic, and permanent magnetic material that can be used to develop highly sensitive systems. Nanocomposite pillars are realized and integrated on magnetic sensor elements to achieve highly sensitive and power efficient flow and tactile sensors. The developed flow sensor can detect air and water flow at a power consumption as little as SO nW and a resolution up to 15 μm/s with easily modifiable performance. A tactile sensor element prototype is realized using the same concept, where a pressure range of 0-169 kPa is detected with a resolution of up to 1.3 kPa. © 2014 IEEE.

  8. Magnetic effects in heavy-ion collisions at intermediate energies

    International Nuclear Information System (INIS)

    Ou Li; Li Baoan

    2011-01-01

    The time evolution and space distribution of internal electromagnetic fields in heavy-ion reactions at beam energies between 200 and 2000 MeV/nucleon are studied within an isospin-dependent Boltzmann-Uhling-Uhlenbeck transport model (ibuu11). While the magnetic field can reach about 7x10 16 G, which is significantly higher than the estimated surface magnetic field (∼1x10 15 G) of magnetars, it has almost no effect on nucleon observables because the Lorentz force is normally much weaker than the nuclear force. Very interestingly, however, the magnetic field generated by the projectilelike (targetlike) spectator has a strong focusing and defocusing effect on positive and negative pions at forward (backward) rapidities. Consequently, the differential π - /π + ratio as a function of rapidity is significantly altered by the magnetic field, whereas the total multiplicities of both positive and negative pions remain about the same. At beam energies above about 1 GeV/nucleon, while the integrated ratio of total π - to π + multiplicities is not, the differential π - /π + ratio is sensitive to the density dependence of nuclear symmetry energy E sym (ρ). Our findings suggest that magnetic effects should be carefully considered in future studies of using the differential π - /π + ratio as a probe of the E sym (ρ) at suprasaturation densities.

  9. Sensitivity is not an intrinsic property of a diagnostic test: empirical evidence from histological diagnosis of Helicobacter pylori infection

    Directory of Open Access Journals (Sweden)

    Carrilho Carla

    2009-12-01

    Full Text Available Abstract Background We aimed to provide empirical evidence of how spectrum effects can affect the sensitivity of histological assessment of Helicobacter pylori infection, which may contribute to explain the heterogeneity in prevalence estimates across populations with expectedly similar prevalence. Methods Cross-sectional evaluation of dyspeptic subjects undergoing upper digestive endoscopy, including collection of biopsy specimens from the greater curvature of the antrum for assessment of H. pylori infection by histopathological study and polymerase chain reaction (PCR, from Portugal (n = 106 and Mozambique (n = 102 following the same standardized protocol. Results In the Portuguese sample the prevalence of infection was 95.3% by histological assessment and 98.1% by PCR. In the Mozambican sample the prevalence was 63.7% and 93.1%, respectively. Among those classified as infected by PCR, the sensitivity of histological assessment was 96.2% among the Portuguese and 66.3% among the Mozambican. Among those testing positive by both methods, 5.0% of the Portuguese and 20.6% of the Mozambican had mild density of colonization. Conclusions This study shows a lower sensitivity of histological assessment of H. pylori infection in Mozambican dyspeptic patients compared to the Portuguese, which may be explained by differences in the density of colonization, and may contribute to explain the heterogeneity in prevalence estimates across African settings.

  10. Multifunctional pH-sensitive magnetic nanoparticles for simultaneous imaging, sensing and targeted intracellular anticancer drug delivery

    International Nuclear Information System (INIS)

    Banerjee, Shashwat S; Chen, D-H

    2008-01-01

    A novel multifunctional magnetic nanocarrier was fabricated for synchronous cancer therapy and sensing. The nanocarrier, programed to display a response to environmental stimuli (pH value), was synthesized by coupling doxorubicin (DOX) to adipic dihydrazide-grafted gum arabic modified magnetic nanoparticles (ADH-GAMNP) via the hydrolytically degradable pH-sensitive hydrazone bond. The resultant nanocarrier, DOX-ADH-GAMNP, had a mean diameter of 13.8 nm and the amount of DOX coupled was about 6.52 mg g -1 . Also, it exhibited pH triggered release of DOX in an acidic environment (pH 5.0) but was relatively stable at physiological pH (pH 7.4). Furthermore, both GAMNP and DOX were found to possess fluorescence properties when excited in the near-infrared region due to the two-photon absorption mechanism. The coupling of DOX to GAMNP resulted in a reversible self-quenching of fluorescence through the fluorescence resonant energy transfer (FRET) between the donor GAMNP and acceptor DOX. The release of DOX from DOX-ADH-GAMNP when exposed to acidic media indicated the recovery of fluorescence from both GAMNP and DOX. The change in the fluorescence intensity of DOX-ADH-GAMNP on the release of DOX can act as a potential sensor to sense the delivery of the drug. The analysis of zeta potential and plasmon absorbance in different pH conditions also confirmed the pH sensitivity of the product. This multifunctional nanocarrier is a significant breakthrough in developing a drug delivery vehicle that combines drug targeting as well as sensing and therapy at the same time.

  11. Synthesis and characterization of foldable and magnetic field-sensitive, freestanding poly(vinyl acetate)/poly(vinyl chloride)/polyfuran composite and nanocomposite films

    Energy Technology Data Exchange (ETDEWEB)

    Sarıtaş, Sevilay; Eşsiz, Serpil; Sarı, Bekir, E-mail: bsari@gazi.edu.tr

    2017-07-01

    Highlights: • In this study, ternary composite/nanocomposite films were synthesized. • Magnetic field-sensitive folding films were prepared without any elastomer. • Morphological studies show that all composite films have a smooth surface. • The ternary composites/nanocomposite show improved thermal stability compared to the pure PF. - Abstract: In this study, polyfuran and poly(vinyl acetate)/poly(vinyl chloride)/polyfuran ternary composites were synthesized via the chemical polymerization method. The temperature and magnetic field–sensitive novel composites and the nanocomposite were obtained in the form of powders and films. It was observed that the prepared novel conductive films have superior properties at a certain temperature range (25–50 °C) such as bending and folding. The structural properties, thermal behavior, surface morphology, internal structure, and surface roughness of the prepared samples were investigated by various characterization techniques. The conductivities of the samples were measured at room temperature and different temperatures by the four-point technique. X-ray Diffraction analysis results demonstrated that the PF and composites have an amorphous structure, whereas the nanocomposite is in crystalline form. The saturation magnetization (Ms) values of the magnetite and nanocomposite were found to be 58.9 and 5.3 emu g{sup −1}, respectively. It was found that magnetite-doped nanocomposite has superparamagnetic properties at room temperature.

  12. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water.

    Science.gov (United States)

    Yu, Hye-Weon; Jang, Am; Kim, Lan Hee; Kim, Sung-Jo; Kim, In S

    2011-09-15

    Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.

  13. Analytical Calculation of the Magnetic Field distribution in a Flux-Modulated Permanent-Magnet Brushless Motor

    DEFF Research Database (Denmark)

    Zhang, Xiaoxu; Liu, Xiao; Chen, Zhe

    2015-01-01

    This paper presents a rapid approach to compute the magnetic field distribution in a flux-modulated permanent-magnet brushless motor. Partial differential equations are used to describe the magnet field behavior in terms of magnetic vector potentials. The whole computational domain is divided...... into several regions, i.e., magnet, air-gaps, slot-openings, and slots. The numerical solution could be obtained by applying the boundary constraints on the interfaces between these regions. The accuracy of the proposed analytical model is verified by comparing the no-load magnetic field and armature reaction...... magnetic field with those calculated by finite element method....

  14. Theory of nuclear magnetic moments - LT-35

    Energy Technology Data Exchange (ETDEWEB)

    Kerman, A. K.

    1952-09-15

    The purpose of these notes is to give an account of some attempts at interpreting the observed values of nuclear magnetic moments. There is no attempt at a complete summary of the field as that would take much more space than is used here. In many cases the arguments are only outlined and references are given for those interested in further details. A discussion of the theory of nuclear magnetic moments necessitates many excursions into the details of the nuclear models because the magnetic moments have a direct bearing on the validity of these models. However the main emphasis here is on those features which tend to explain the magnetic moments and other evidence is not discussed unless it has a direct bearing on the problem. In the first part of the discussion the Shell Model of the nucleus is used, as this model seems to correlate a large body of data relating to the heavier nuclei. Included here are the modifications proposed to explain the fact that the experimental magnetic moments do not fit quantitatively with the exact predictions of the Shell Model. The next sections deal with some of the more drastic modifications introduced to explain the large nuclear quadrupole moments and the effect of these modifications on the magnetic moments. Finally we turn to more detailed investigations of the light nuclei, in particular the - Conjugate nuclei. (author)

  15. Acquisition and processing method for human sensorial, sensitive, motory and phonatory circuits reaction times

    International Nuclear Information System (INIS)

    Doche, Claude

    1972-01-01

    This work describes a storage and acquisition device and a method for human sensorial and sensitive motory and phonatory reaction times. The considered circuits are those made with the visual, auditory and sensory receptor organs and the motory or phonatory effector organs. The anatomo-physiological localization of these circuits allows us to appreciate the possibilities of the central nervous system for different angles. The experimental population is made of normal and pathological individuals (individuals having tumoral or vascular, localized or diffused cerebral lesions or parkinsonian individuals). The parameter processing method is based on the multivariate analysis results and allows us to position each individual compared to a normal individual and to appreciate the weight of each circuit in this positioning. Clinical exploitation results give to this method a prognosis and therapeutic interest. It seems though untimely to talk about its diagnosis value. (author) [fr

  16. Highly sensitive hydrogen detection of catalyst-free ZnO nanorod networks suspended by lithography-assisted growth

    International Nuclear Information System (INIS)

    Huh, Junghwan; Kim, Gyu Tae; Park, Jonghyurk; Park, Jeong Young

    2011-01-01

    We have successfully demonstrated a ZnO nanorod-based 3D nanostructure to show a high sensitivity and very fast response/recovery to hydrogen gas. ZnO nanorods have been synthesized selectively over the pre-defined area at relatively low temperature using a simple self-catalytic solution process assisted by a lithographic method. The conductance of the ZnO nanorod device varies significantly as the concentration of the hydrogen is changed without any additive metal catalyst, revealing a high sensitivity to hydrogen gas. Its superior performance can be explained by the porous structure of its three-dimensional network and the enhanced surface reaction of the hydrogen molecules with the oxygen defects resulting from a high surface-to-volume ratio. It was found that the change of conductance follows a power law depending on the hydrogen concentration. A Langmuir isotherm following an ideal power law and a cross-over behavior of the activation energy with respect to hydrogen concentration were observed. This is a very novel and intriguing phenomenon on nanostructured materials, which suggests competitive surface reactions in ZnO nanorod gas sensors.

  17. Highly sensitive hydrogen detection of catalyst-free ZnO nanorod networks suspended by lithography-assisted growth.

    Science.gov (United States)

    Huh, Junghwan; Park, Jonghyurk; Kim, Gyu Tae; Park, Jeong Young

    2011-02-25

    We have successfully demonstrated a ZnO nanorod-based 3D nanostructure to show a high sensitivity and very fast response/recovery to hydrogen gas. ZnO nanorods have been synthesized selectively over the pre-defined area at relatively low temperature using a simple self-catalytic solution process assisted by a lithographic method. The conductance of the ZnO nanorod device varies significantly as the concentration of the hydrogen is changed without any additive metal catalyst, revealing a high sensitivity to hydrogen gas. Its superior performance can be explained by the porous structure of its three-dimensional network and the enhanced surface reaction of the hydrogen molecules with the oxygen defects resulting from a high surface-to-volume ratio. It was found that the change of conductance follows a power law depending on the hydrogen concentration. A Langmuir isotherm following an ideal power law and a cross-over behavior of the activation energy with respect to hydrogen concentration were observed. This is a very novel and intriguing phenomenon on nanostructured materials, which suggests competitive surface reactions in ZnO nanorod gas sensors.

  18. A sensitive magnetic field sensor using BPSCCO thick film

    Indian Academy of Sciences (India)

    Unknown

    Figure 4. a. Hysteretic characteristics of the sensor #1 at liquid nitrogen temperature for magnetic field between – 40 and. + 40 mT and b. hysteretic characteristics of the sensor #1 at liquid nitrogen temperature for magnetic field between – 12 and. + 12 mT. 1. 2. 3. 4. 5. 6. 7. 0. 30. 60. 90. 120. R. 77. (ohm). 1st cycle. 2nd cycle.

  19. Magnetic Pd-Fe{sub 3}O{sub 4} heterodimer nanocrystals as recoverable catalysts for ligand-free hiyama cross-coupling reactions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Sup; Byun, Sang Moon; Kwon, Jung Min; Kim, B. Moon [Dept. of Chemistry, College of Natural Sciences, Seoul National University, Seoul (Korea, Republic of)

    2016-12-15

    Ligand-free Hiyama cross-coupling reaction was achieved through the use of Pd-Fe{sub 3}O{sub 4} heterodimeric nanocrystals (1 mol% in Pd) as recyclable catalysts. The nanocrystal catalysts exhibited good activities accommodating a variety of substrates including aryl bromides and iodides with substituents of varying electronic and steric properties. Furthermore, the nanocrystal catalyst could be conveniently recovered with the aid of an external magnet and recycled five times without the loss of catalytic activity to a considerable degree.

  20. Reactions the private life of atoms

    CERN Document Server

    Atkins, Peter

    2011-01-01

    Through an innovative, closely integrated design of images and text, and his characteristically clear, precise, and economical exposition, Peter Atkins explains the processes involved in chemical reactions. He begins by introducing a 'tool kit' of basic reactions, such as precipitation, corrosion, and catalysis, and concludes by showing how these building blocks are brought together in more complex processes such as photosynthesis.

  1. Life on magnets: stem cell networking on micro-magnet arrays.

    Directory of Open Access Journals (Sweden)

    Vitalii Zablotskii

    Full Text Available Interactions between a micro-magnet array and living cells may guide the establishment of cell networks due to the cellular response to a magnetic field. To manipulate mesenchymal stem cells free of magnetic nanoparticles by a high magnetic field gradient, we used high quality micro-patterned NdFeB films around which the stray field's value and direction drastically change across the cell body. Such micro-magnet arrays coated with parylene produce high magnetic field gradients that affect the cells in two main ways: i causing cell migration and adherence to a covered magnetic surface and ii elongating the cells in the directions parallel to the edges of the micro-magnet. To explain these effects, three putative mechanisms that incorporate both physical and biological factors influencing the cells are suggested. It is shown that the static high magnetic field gradient generated by the micro-magnet arrays are capable of assisting cell migration to those areas with the strongest magnetic field gradient, thereby allowing the build up of tunable interconnected stem cell networks, which is an elegant route for tissue engineering and regenerative medicine.

  2. Site-specific growth of Au-Pd alloy horns on Au nanorods: A platform for highly sensitive monitoring of catalytic reactions by surface enhancement raman spectroscopy

    KAUST Repository

    Huang, Jianfeng; Zhu, Yihan; Lin, Ming; Wang, Qingxiao; Zhao, Lan; Yang, Yang; Yao, Kexin; Han, Yu

    2013-01-01

    Surface-enhanced Raman scattering (SERS) is a highly sensitive probe for molecular detection. The aim of this study was to develop an efficient platform for investigating the kinetics of catalytic reactions with SERS. To achieve this, we synthesized

  3. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  4. On the existence of hot positronium reactions

    International Nuclear Information System (INIS)

    Lazzarini, E.

    1984-01-01

    The existence of hot Ps reactions is nowadays questioned; the controversy arises from the two models (the Ore gap and the spur theories) advanced in order to explain the mechanism of the positronium formation and of its inhibition in liquids by dissolution of certain compounds. The hypothesis of the hot Ps reactions was initially advanced as an additional statement for explaining the inhibition phenomenon within the framework of the Ore gap theory, but it is not considered necessary for the spur theory. The present paper is chiefly intended as a presentation of this particular aspect of Ps chemistry to hot atom chemists unspecialized in the field. The reader is assumed to be familiar with the basic physics and experimental methods used in positronium chemistry. Contents: positrons and positronium formation; inhibition and enhancement of Ps formation in solutions; positronium reactions in gases. (Auth.)

  5. SENSIT: a cross-section and design sensitivity and uncertainty analysis code. [In FORTRAN for CDC-7600, IBM 360

    Energy Technology Data Exchange (ETDEWEB)

    Gerstl, S.A.W.

    1980-01-01

    SENSIT computes the sensitivity and uncertainty of a calculated integral response (such as a dose rate) due to input cross sections and their uncertainties. Sensitivity profiles are computed for neutron and gamma-ray reaction cross sections of standard multigroup cross section sets and for secondary energy distributions (SEDs) of multigroup scattering matrices. In the design sensitivity mode, SENSIT computes changes in an integral response due to design changes and gives the appropriate sensitivity coefficients. Cross section uncertainty analyses are performed for three types of input data uncertainties: cross-section covariance matrices for pairs of multigroup reaction cross sections, spectral shape uncertainty parameters for secondary energy distributions (integral SED uncertainties), and covariance matrices for energy-dependent response functions. For all three types of data uncertainties SENSIT computes the resulting variance and estimated standard deviation in an integral response of interest, on the basis of generalized perturbation theory. SENSIT attempts to be more comprehensive than earlier sensitivity analysis codes, such as SWANLAKE.

  6. Magnetic moment oscillation in ammonium perchlorate in a DC SQUID-based magnetic resonance experiment

    International Nuclear Information System (INIS)

    Montero, V.; Cernicchiaro, G.

    2008-01-01

    In this work we describe experimental results in which a DC SQUID (superconducting quantum interference device) is used as free induction decay detector. Measurements of a solid ammonium perchlorate (NH 4 ClO 4 ) sample were performed, in zero field, at 4.2 K. Unexpected magnetic moment oscillations were detected at 1.5 kHz. The computation of the magnetic fields suggests that the proton nuclear magnetic resonance may explain the measured resonance, considering reorientation of the ammonium group by quantum tunneling of protons and a magnetic proton dipole-dipole intermolecular interaction model

  7. Theory of triplet-triplet annihilation in optically detected magnetic resonance

    Science.gov (United States)

    Keevers, T. L.; McCamey, D. R.

    2016-01-01

    Triplet-triplet annihilation allows two low-energy photons to be upconverted into a single high-energy photon. By essentially engineering the solar spectrum, this allows solar cells to be made more efficient and even exceed the Shockley-Quiesser limit. Unfortunately, optimizing the reaction pathway is difficult, especially with limited access to the microscopic time scales and states involved in the process. Optical measurements can provide detailed information: triplet-triplet annihilation is intrinsically spin dependent and exhibits substantial magnetoluminescence in the presence of a static magnetic field. Pulsed optically detected magnetic resonance is especially suitable, since it combines high spin sensitivity with coherent manipulation. In this paper, we develop a time-domain theory of triplet-triplet annihilation for complexes with arbitrary spin-spin coupling. We identify unique "Rabi fingerprints" for each coupling regime and show that this can be used to characterize the microscopic Hamiltonian.

  8. Structure sensitivity in adsorption

    DEFF Research Database (Denmark)

    Hammer, Bjørk; Nielsen, Ole Holm; Nørskov, Jens Kehlet

    1997-01-01

    The structure sensitivity of CO adsorption on different flat, stepped, kinked and reconstructed Pt surfaces is studied using large-scale density-functional calculations. We find an extremely strong structure sensitivity in the adsorption energy with variations up to 1 eV (or 100%) from one...... structure to the next. We propose a model to explain this behavior, and use it to discuss more generally the origin of structure sensitivity in heterogeneous catalysis....

  9. Use of magnetic resonance imaging in the evaluation of spondylolysis.

    Science.gov (United States)

    Rush, Jeremy K; Astur, Nelson; Scott, Stephanie; Kelly, Derek M; Sawyer, Jeffrey R; Warner, William C

    2015-01-01

    In early studies, magnetic resonance imaging (MRI) had low sensitivity and positive predictive value in the evaluation of the pars interarticularis pathology; however, more recent reports have suggested an expanded role for MRI. The purpose of the present study was to evaluate the effectiveness of MRI in the diagnosis of pars injuries and compare it to computed tomography (CT), which was used as the reference "gold standard" for the detection of fractures. The radiographic and clinic data of 93 adolescents and young adults with a presumptive diagnosis of spondylolysis based upon history and clinic examination were reviewed. Only 26 patients who had MRI and CT images obtained within 30 days of each other were included. All images were reviewed by a fellowship-trained musculoskeletal radiologist and fellowship-trained pediatric orthopaedist. Overall, 39 individual pars lesions (stress reaction or fracture) were identified. MRI was effective in identifying 36 pars lesions. MRI identified 11 lesions in 9 patients with negative CT. Seven of these lesions were stress reactions (grade 1), whereas 4 were frank fractures. Three pars injuries were noted on CT while the MRI was negative. MRI is an effective method (92% sensitivity) for detecting pars injuries. It can detect stress reactions when a fracture is not visible on CT scan, allowing early treatment of these prelysis lesions. The 92% sensitivity of MRI is comparable with that of other diagnostic modalities such as bone scan, with the advantage of no radiation exposure. MRI should be strongly considered as the advanced imaging modality of choice in the evaluation of patients with suspected spondylolysis. Level III-diagnostic study.

  10. Fatal anaphylactic reaction to intravenous gadobutrol, a gadolinium-based MRI contrast agent

    Directory of Open Access Journals (Sweden)

    Sabine Franckenberg, MD

    2018-02-01

    Full Text Available We present the rare case of a fatal anaphylactic reaction to gadobutrol, a magnetic resonance imaging contrast agent, in a 42-year-old man. The patient underwent elective magnetic resonance imaging for diagnostic clarification of a suspicious finding in the abdomen. The patient had undergone contrast-enhanced computed tomography previously without the occurrence of any adverse effects. Adverse drug reactions in gadobutrol have a very low prevalence of 0.32%-3.5%, with serious adverse drug reactions in <0.1%. There are only a few cases of fatal anaphylactoid reactions to gadolinium-based contrast agents in general. However, if an anaphylactoid reaction occurs, it can present itself with a fulminant course within minutes.

  11. Effect of Low-Frequency AC Magnetic Susceptibility and Magnetic Properties of CoFeB/MgO/CoFeB Magnetic Tunnel Junctions

    Directory of Open Access Journals (Sweden)

    Yuan-Tsung Chen

    2014-01-01

    Full Text Available In this investigation, the low-frequency alternate-current (AC magnetic susceptibility (χac and hysteresis loop of various MgO thickness in CoFeB/MgO/CoFeB magnetic tunneling junction (MTJ determined coercivity (Hc and magnetization (Ms and correlated that with χac maxima. The multilayer films were sputtered onto glass substrates and the thickness of intermediate barrier MgO layer was varied from 6 to 15 Å. An experiment was also performed to examine the variation of the highest χac and maximum phase angle (θmax at the optimal resonance frequency (fres, at which the spin sensitivity is maximal. The results reveal that χac falls as the frequency increases due to the relationship between magnetization and thickness of the barrier layer. The maximum χac is at 10 Hz that is related to the maximal spin sensitivity and that this corresponds to a MgO layer of 11 Å. This result also suggests that the spin sensitivity is related to both highest χac and maximum phase angle. The corresponding maximum of χac is related to high exchange coupling. High coercivity and saturation magnetization contribute to high exchange-coupling χac strength.

  12. Asymmetric H-D exchange reactions of fluorinated aromatic ketones

    KAUST Repository

    Zhao, Yujun; Lim, XiaoZhi; Pan, Yuanhang; Zong, Lili; Feng, Wei; Tan, Choonhong; Huang, Kuo-Wei

    2012-01-01

    Chiral bicyclic guanidine catalyzes the asymmetric H-D exchange reactions. Up to 30% ee was achieved. DFT calculations were employed to elucidate and explain the origin of the reaction's stereoselectivity. © 2012 The Royal Society of Chemistry.

  13. Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design

    International Nuclear Information System (INIS)

    Paulsen, Jeffrey L; Franck, John; Demas, Vasiliki; Bouchard, Louis-S.

    2008-01-01

    Single-sided and mobile nuclear magnetic resonance (NMR) sensors have the advantages of portability, low cost, and low power consumption compared to conventional high-field NMR and magnetic resonance imaging (MRI) systems. We present fast, flexible, and easy-to-implement target field algorithms for mobile NMR and MRI magnet design. The optimization finds a global optimum in a cost function that minimizes the error in the target magnetic field in the sense of least squares. When the technique is tested on a ring array of permanent-magnet elements, the solution matches the classical dipole Halbach solution. For a single-sided handheld NMR sensor, the algorithm yields a 640 G field homogeneous to 16,100 ppm across a 1.9 cc volume located 1.5 cm above the top of the magnets and homogeneous to 32,200 ppm over a 7.6 cc volume. This regime is adequate for MRI applications. We demonstrate that the homogeneous region can be continuously moved away from the sensor by rotating magnet rod elements, opening the way for NMR sensors with adjustable 'sensitive volumes'

  14. Sensitive inexpensive spectrophotometric and spectrofluorimetric analysis of ezogabine, levetiracetam and topiramate in tablet formulations using Hantzsch condensation reaction

    Science.gov (United States)

    Ibrahim, F. A.; El-Yazbi, A. F.; Wagih, M. M.; Barary, M. A.

    2017-09-01

    Two highly sensitive, simple and selective spectrophotometric and spectrofluorimetric assays have been investigated for the analysis of ezogabine, levetiracetam and topiramate in their pure and in pharmaceutical dosage forms. The suggested methods depend on the condensation of the primary amino-groups in the three drugs with acetylacetone and formaldehyde according to Hantzsch reaction yielding highly fluorescent yellow colored dihydropyridine derivatives. The reaction products of ezogabine, levetiracetam and topiramate were measured spectrophotometrically at 418, 390 and 380 nm or spectrofluorimetrically at λem/ex of 495/425 nm, 490/415 nm and 488/410 nm, respectively. Various experimental conditions have been carefully studied to maximize the reaction yield. At the optimum reaction conditions, the calibration curves were rectilinear over the concentration ranges of 8-25, 60-180 and 80-200 μg/mL spectrophotometrically and 0.02-0.2, 0.2-1.2 and 0.2-1.5 μg/mL spectrofluorimetrically for ezogabine, levetiracetam and topiramate, respectively with good correlation coefficients. The suggested methods were applied successfully for the analysis of ezogabine, levetiracetam and topiramate in their commercial tablets with high percentage recoveries and negligible interference from various excipients in pharmaceutical dosage forms. The results were statistically analyzed and showed the absence of any significant difference between both developed and published methods. The procedures were validated and evaluated by the ICH guidelines revealing good reproducibility and accuracy. Therefore, the two proposed methods may be considered of high interest for practical and reliable analysis of ezogabine, levetiracetam and topiramate in pharmaceutical dosage forms.

  15. Flat magnetic exchange springs as mechanism for additional magnetoresistance in magnetic nanoisland arrays

    Energy Technology Data Exchange (ETDEWEB)

    Boltaev, A.P.; Pudonin, F.A. [P. N. Lebedev Physical Institute of the Russian Academy of Sciences, Leninskiy Prospekt 53, 119991 Moscow (Russian Federation); Sherstnev, I.A., E-mail: sherstnev@lebedev.ru [P. N. Lebedev Physical Institute of the Russian Academy of Sciences, Leninskiy Prospekt 53, 119991 Moscow (Russian Federation); Egorov, D.A. [National Research Nuclear University MEPhI, Kashirskoe shosse 31, 115409 Moscow (Russian Federation); Kozmin, A.M. [National Research University of Electronic Technology, Shokin Square, 1, Zelenograd, 124482 Moscow (Russian Federation)

    2017-04-15

    Process of magnetization and magnetoresistance have been studied in nanoisland bilayer systems of FeNi-Co. Hysteresis loops show characteristic features (steps) most clearly observed in certain orientations of the sample in a magnetic field. To explain these features the concept of flat magnetic exchange spring has been introduced for nanoisland bilayers. It has been proposed that additional magnetoresistance can be the result of spin-dependent scattering of electrons in the area of flat magnetic exchange spring. Magnetoresistance studies of bilayer systems has shown that additional magnetoresistance occurs at the same magnetic fields as steps on hysteresis loops. - Highlights: • Metallic FeNi-Co bilayers are studied. • FeNi and Co layers magnetize independently. • Concept of flat spin spring is proposed. • Additional magnetoresistance occurs in intermediate magnetic fields.

  16. Flat magnetic exchange springs as mechanism for additional magnetoresistance in magnetic nanoisland arrays

    International Nuclear Information System (INIS)

    Boltaev, A.P.; Pudonin, F.A.; Sherstnev, I.A.; Egorov, D.A.; Kozmin, A.M.

    2017-01-01

    Process of magnetization and magnetoresistance have been studied in nanoisland bilayer systems of FeNi-Co. Hysteresis loops show characteristic features (steps) most clearly observed in certain orientations of the sample in a magnetic field. To explain these features the concept of flat magnetic exchange spring has been introduced for nanoisland bilayers. It has been proposed that additional magnetoresistance can be the result of spin-dependent scattering of electrons in the area of flat magnetic exchange spring. Magnetoresistance studies of bilayer systems has shown that additional magnetoresistance occurs at the same magnetic fields as steps on hysteresis loops. - Highlights: • Metallic FeNi-Co bilayers are studied. • FeNi and Co layers magnetize independently. • Concept of flat spin spring is proposed. • Additional magnetoresistance occurs in intermediate magnetic fields.

  17. Enhanced emission of high-energy photons perpendicular to the reaction plane in α+Th reactions

    International Nuclear Information System (INIS)

    Tegner, P.; Marianski, B.; Morsch, H.P.; Rogge, M.; Bargholtz, C.; Decowski, P.; Zemlo, L.

    1991-01-01

    High-energy photon and neutron emission has been measured in coincidence with fission fragments in α+ 232 Th reactions at 170 MeV. From measurements parallel and perpendicular to the fission plane, anisotropies relative to the reaction plane were determined. The in-plane/out-of-plane intensity ratio is 0.72(7) for photons with energies above 20 MeV and 11(3) for neutrons at 35 MeV. The result for high-energy photons can be explained by nucleon-nucleon bremsstrahlung if the initial flow of nucleons has a correlation to the reaction plane similar to the one observed for fast neutrons

  18. L10-MnGa based magnetic tunnel junction for high magnetic field sensor

    Science.gov (United States)

    Zhao, X. P.; Lu, J.; Mao, S. W.; Yu, Z. F.; Wang, H. L.; Wang, X. L.; Wei, D. H.; Zhao, J. H.

    2017-07-01

    We report on the investigation of the magnetic tunnel junction structure designed for high magnetic field sensors with a perpendicularly magnetized L10-MnGa reference layer and an in-plane magnetized Fe sensing layer. A large linear tunneling magnetoresistance ratio up to 27.4% and huge dynamic range up to 5600 Oe have been observed at 300 K, with a low nonlinearity of 0.23% in the optimized magnetic tunnel junction (MTJ). The field response of tunneling magnetoresistance is discussed to explain the field sensing properties in the dynamic range. These results indicate that L10-MnGa based orthogonal MTJ is a promising candidate for a high performance magnetic field sensor with a large dynamic range, high endurance and low power consumption.

  19. Magnetization process in antiferromagnetic EuPdIn

    International Nuclear Information System (INIS)

    Ito, T.; Nishigori, S.; Hiromitsu, I.

    1998-01-01

    Magnetization and magnetic susceptibility measurements have been m[e on EuPdIn single crystals. Isothermal magnetization curves measured along the a-, b- and c-axis exhibit three anomalies at the maximum. The phase diagrams determined by the critical fields are explained by the molecular field theory in weak magnetocrystalline anisotropy. (orig.)

  20. The effects of magnetic perturbations on plasma transport or is magnetic turbulence important in tokamaks?

    International Nuclear Information System (INIS)

    Wootton, A.J.

    1993-01-01

    A test particle model is verified and then used to interpret estimates of fast electron diffusivities in terms of magnetic fluctuation levels. The implied fluctuation levels are themselves interpreted with another verified model to predict electron thermal diffusivities. If the fast electron diffusivities represent local values, then the implied associated thermal transport is too small to explain experimental values. That is, magnetic fluctuations are not important. However, if the fast electron diffusivities represent effective values across mixed good (i.e. with no magnetic fluctuations) and bad (with magnetic fluctuations) surfaces then the implied magnetic fluctuation levels can influence electron thermal transport. (author)

  1. Solar magnetism: a new look

    International Nuclear Information System (INIS)

    Golub, L.

    1981-01-01

    With the growing evidence for the ubiquity of magnetic fields, researchers feel a growing need for an adequate theory for the generation of such fields in nature. This article looks at the sun and its magnetic fields. The fundamental property that must be explained aside from the existence of magnetic fields is the solar cycle. The traditional picture of the solar cycle has three primary components: (1) solar activity; (2) latitude migration; and (3) Hale's law and reversal of polarity. The aspects of internal motion which can generate magnetic fields and cycles of activity like those observed are discussed. There are two major elements to the flow patterns of the sun. More important than the visible differential rotation of solar surface is the belief that the sun's interior rotates faster than the surface. It is this mechanism which probably produces the magnetic fields which bubble up from interior. It's also possible to show that this mechanism can produce the migration of solar activity. The reversal of polarity is explained by convection zones and sun's rotation. Due to x-ray imaging and improved magnetic field measurements, it has been observed that enormous quantities of magnetic flux emerge from solar interior in form of very small regions. This data along with rocket data show that the rate of generation of magnetic flux does not change during a solar cycle - instead, the observed cycle represents a shift from large emerging regions to numerous small regions and back again

  2. Magnetophoresis behaviour at low gradient magnetic field and size control of nickel single core nanobeads

    Energy Technology Data Exchange (ETDEWEB)

    Benelmekki, M., E-mail: benelmekki@fisica.uminho.p [Centro de Fisica, Universidade do Minho, Braga (Portugal); Montras, A. [Sepmag Tecnologies, Parc Tecnologic del Valles, Barcelona (Spain); Martins, A.J.; Coutinho, P.J.G. [Centro de Fisica, Universidade do Minho, Braga (Portugal); Martinez, Ll.M. [Sepmag Technologies, Atlanta, GA (United States)

    2011-08-15

    Magnetic separation of organic compounds, proteins, nucleic acids and other biomolecules, and cells from complex reaction mixtures is becoming the most suitable solution for large production in bioindustrial purification and extraction processes. Optimal magnetic properties can be achieved by the use of metals. However, they are extremely sensitive to oxidation and degradation under atmospheric conditions. In this work Ni nanoparticles are synthesised by conventional solution reduction process with the addition of a non-ionic surfactant as a surface agent. The nanoparticles were surfacted in citric acid and then coated with silica to form single core Ni nanobeads. A magnetophoresis study at different magnetic field gradients and at the different steps of synthesis route was performed using Horizontal Low Gradient Magnetic Field (HLGMF) systems. The reversible aggregation times are reduced to a few seconds, allowing a very fast separation process. - Research highlights: Monodispersed single core Ni-silica core-shell structures were prepared. Control of Ni nanoparticles size was achieved using a non-ionic surfactant. Magnetophoresis at different magnetic field gradients was monitored. Magnetophoresis at different steps of synthesis route was performed. Attractive magnetic interactions overcome electrostatic repulsions.

  3. A facile one-pot solvothermal method for synthesis of magnetically recoverable Pd-Fe3O4 hybrid nanocatalysts for the Mizoroki-Heck reaction

    Science.gov (United States)

    Zhen, Fangchen; Ran, Maofei; Chu, Wei; Jiang, Chengfa; Sun, Wenjing

    2018-03-01

    Pd-Fe3O4 hybrid nanostructures were prepared using a simple one-pot hydrothermal method. The prepared materials were characterized by Fourier transform-infrared spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy, inductively coupled plasma, N2 adsorption-desorption, and vibrating sample magnetometry. This self-assembled nanosystem acted as an efficient magnetically recyclable noble metal-based multi-functional nanocatalyst. It showed excellent catalytic activity and stability for the Heck reaction of iodobenzene and styrene under mild conditions. The methods used to prepare the Pd-Fe3O4 catalysts were simple and low-cost, which will be useful for the large-scale development and application of a magnetically recoverable Pd catalyst.

  4. On-chip measurement of the Brownian relaxation frequency of magnetic beads using magnetic tunneling junctions

    DEFF Research Database (Denmark)

    Donolato, M.; Sogne, E.; Dalslet, Bjarke Thomas

    2011-01-01

    We demonstrate the detection of the Brownian relaxation frequency of 250 nm diameter magnetic beads using a lab-on-chip platform based on current lines for exciting the beads with alternating magnetic fields and highly sensitive magnetic tunnel junction (MTJ) sensors with a superparamagnetic free...

  5. A hybrid charged-particle guide for studying (n, charged particle) reactions

    International Nuclear Information System (INIS)

    Haight, R.C.; White, R.M.; Zinkle, S.J.

    1983-01-01

    Charged-particle transport systems consisting of magnetic quadrupole lenses have been employed in recent years in the study of (n, charged particle) reactions. A new transport system was completed at the laboratory that is based both on magnetic lenses as well as electrostatic fields. The magnetic focusing of the charged-particle guide is provided by six magnetic quadrupole lenses arranged in a CDCCDC sequence (in the vertical plane). The electrostatic field is produced by a wire at high voltage which stretches the length of the guide and is physically at the centre of the magnetic axis. The magnetic lenses are used for charged particles above 5 MeV; the electrostatic guide is used for lower energies. This hybrid system possesses the excellent focusing and background rejection properties of other magnetic systems. For low energy charged-particles, the electrostatic transport avoids the narrow band-passes in charged-particle energy which are a problem with purely magnetic transport systems. This system is installed at the LLNL Cyclograaff facility for the study of (n, charged particle) reactions at neutron energies up to 35 MeV. (Auth.)

  6. Sensitization and allergy to Cannabis sativa leaves in a population of tomato (Lycopersicon esculentum)-sensitized patients.

    Science.gov (United States)

    de Larramendi, Carlos Hernando; Carnés, Jerónimo; García-Abujeta, José Luís; García-Endrino, Ana; Muñoz-Palomino, Elena; Huertas, Angel Julio; Fernández-Caldas, Enrique; Ferrer, Angel

    2008-01-01

    Cases of allergy to Cannabis sativa have occasionally been reported, but both the allergenic profile and eventual cross-reactivity pattern remain unknown. To analyze the allergenic profile of a population of patients from Spain sensitized to C. sativa and to characterize the C. sativa leaf extract. A total of 32 subjects were enrolled in the study: group A, 10 individuals sensitized to tomato, reporting reactions by contact or inhalation to Cannabis; group B, 14 individuals sensitized to tomato, without reactions to Cannabis; group C, 8 individuals not sensitized to tomato and without reactions to Cannabis. Sensitivity to Cannabis, tomato and peach peel, Platanus hybrida and Artemisia vulgaris pollen extracts was measured by skin tests and specific IgE. Individual immunoblots and inhibition experiments with a pool of sera were conducted. All tomato-sensitized subjects (and 1 negative) had positive skin tests to C. sativa leaves and hashish. Specific IgE to C. sativa and peach peel was more common than to tomato. Immunoblot experiments showed 2 prominent bands of 10 and 14 kDa and 2 weakly recognized bands of 30 and 45 kDa. Tomato, peach and A. vulgaris extracts inhibited most of the bands present in C. sativa. P. hybrida inhibited only the high-molecular-weight bands. Sensitization to C. sativa with or without symptoms is frequent among patients in Spain sensitized to tomato. C. sativa leaves are a potential allergenic source and their allergens may cross-react with other allergenic sources from plants (fruit peels and pollen). (c) 2008 S. Karger AG, Basel

  7. Magnetically recoverable nanocatalysts

    KAUST Repository

    Polshettiwar, Vivek

    2011-05-11

    A broad overview on magnetically recoverable nanocatalysts is presented and the use of magnetic nanomaterials as catalysts is discussed. Magnetic materials are used as organocatalysts and their applications range to challenging reactions, such as hydroformylation and olefin metathesis. Magnetic nanomaterials are also being used in environmental applications, such as for photo- and biocatalysis and for the adsorption and removal of pollutants from air and water. These materials show great promise as enantioselective catalysts, which are used extensively for the synthesis of medicines, drugs, and other bioactive molecules. By functionalizing these materials using chiral ligands, a series of chiral nanocatalysts can be designed, offering great potential to reuse these otherwise expensive catalyst systems. Characterization of magnetic catalysts is often a challenging task, and NMR characterization of these catalysts is difficult because the magnetic nature of the materials interferes with the magnetic field of the spectrometer.

  8. Magnetically recoverable nanocatalysts

    KAUST Repository

    Polshettiwar, Vivek; Luque, Rafael L.; Fihri, Aziz; Zhu, Haibo; Bouhrara, Mohamed; Basset, Jean-Marie

    2011-01-01

    A broad overview on magnetically recoverable nanocatalysts is presented and the use of magnetic nanomaterials as catalysts is discussed. Magnetic materials are used as organocatalysts and their applications range to challenging reactions, such as hydroformylation and olefin metathesis. Magnetic nanomaterials are also being used in environmental applications, such as for photo- and biocatalysis and for the adsorption and removal of pollutants from air and water. These materials show great promise as enantioselective catalysts, which are used extensively for the synthesis of medicines, drugs, and other bioactive molecules. By functionalizing these materials using chiral ligands, a series of chiral nanocatalysts can be designed, offering great potential to reuse these otherwise expensive catalyst systems. Characterization of magnetic catalysts is often a challenging task, and NMR characterization of these catalysts is difficult because the magnetic nature of the materials interferes with the magnetic field of the spectrometer.

  9. Ionizing radiation induced attachment reactions of nucleic acids and their components

    International Nuclear Information System (INIS)

    Myers, L.S. Jr.

    1975-01-01

    An extensive bibliographic review is given of experimental and theoretical data on radiation-induced attachment reactions of nucleic acids and their components. Mechanisms of these reactions are reviewed. The reactions with water, formate, and alcohols, with amines and other small molecules, and with radiation sensitizers and nucleic acid-nucleic acid reactions are discussed. Studies of the reaction mechanisms show that many of the reactions occur by radical-molecule reactions, but radical-radical reactions also occur. Radiation modifiers become attached to nucleic acids in vitro and in vivo and there are indications that attachment may be necessary for the action of some sensitizers. (U.S.)

  10. Control of magnetism by electrical charge doping or redox reactions in a surface-oxidized Co thin film with a solid-state capacitor structure

    Science.gov (United States)

    Hirai, T.; Koyama, T.; Chiba, D.

    2018-03-01

    We have investigated the electric field (EF) effect on magnetism in a Co thin film with a naturally oxidized surface. The EF was applied to the oxidized Co surface through a gate insulator layer made of HfO2, which was formed using atomic layer deposition (ALD). The efficiency of the EF effect on the magnetic anisotropy in the sample with the HfO2 layer deposited at the appropriate temperature for the ALD process was relatively large compared to the previously reported values with an unoxidized Co film. The coercivity promptly and reversibly followed the variation in gate voltage. The modulation of the channel resistance was at most ˜0.02%. In contrast, a dramatic change in the magnetic properties including the large change in the saturation magnetic moment and a much larger EF-induced modulation of the channel resistance (˜10%) were observed in the sample with a HfO2 layer deposited at a temperature far below the appropriate temperature range. The response of these properties to the gate voltage was very slow, suggesting that a redox reaction dominated the EF effect on the magnetism in this sample. The frequency response for the capacitive properties was examined to discuss the difference in the mechanism of the EF effect observed here.

  11. Magnetoresistance and magnetic breakdown phenomenon in amorphous magnetic alloys

    International Nuclear Information System (INIS)

    Chen Hui-yu; Gong Xiao-yu

    1988-01-01

    Transverse magnetoresistance in amorphous magnetic alloys (Fe/sub 1-//sub x/CO/sub x/) 82 Cu/sub 0.4/Si/sub 4.4/B/sub 13.2/ were measured at room temperature and in the magnetic field range 0--15 kOe. For large magnetic field, three different functional dependences of magnetoresistance on magnetic field strength have been found as follows: (1) Δrho/rho approaches saturation. (2) Δrho/rho increases proportionally to H 2 . (3) For x = 0.15, a sharp Δrho/rho peak appears at a certain magnetic field strength in spatial angular orientation of both magnetic field and electric currents. Case (3) is a magnetic breakdown phenomenon. Magnetic breakdown occurs at the gap between the spin-up and spin-down sheets of the Fermi surface. This gap is the spin-orbit gap and its magnitude is a sensitive function of magnetization. Hence the magnitude and width of the magnetoresistance peak and the magnetic field strength at the peak point are functions of angular orientation of both magnetic field and electric current

  12. Handbook of Advanced Magnetic Materials

    CERN Document Server

    Liu, Yi; Shindo, Daisuke

    2006-01-01

    From high-capacity, inexpensive hard drives to mag-lev trains, recent achievements in magnetic materials research have made the dreams of a few decades ago reality. The objective of Handbook of Advanced Magnetic Materials is to provide a timely, comprehensive review of recent progress in magnetic materials research. This broad yet detailed reference consists of four volumes: 1.) Nanostructured advanced magnetic materials, 2.) Characterization and simulation of advanced magnetic materials, 3.) Processing of advanced magnetic materials, and 4.) Properties and applications of advanced magnetic materials The first volume documents and explains recent development of nanostructured magnetic materials, emphasizing size effects. The second volume provides a comprehensive review of both experimental methods and simulation techniques for the characterization of magnetic materials. The third volume comprehensively reviews recent developments in the processing and manufacturing of advanced magnetic materials. With the co...

  13. Effect of single vacancy on the structural, electronic structure and magnetic properties of monolayer graphyne by first-principles

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jiangni, E-mail: niniyun@nwu.edu.cn; Zhang, Yanni; Xu, Manzhang; Wang, Keyun; Zhang, Zhiyong

    2016-10-01

    The effect of single vacancy on the structural, electronic and magnetic properties of monolayer graphyne is investigated by the first-principles calculations. The calculated results reveal that single vacancy can result in the spin polarization in monolayer graphyne and the spin polarization is sensitive to local geometric structure of the vacancy. In the case of monolayer graphyne with one single vacancy at the sp{sup 2} hybridized C site, the vacancy introduces rather weakly spin-polarized, flat bands in the band gap. Due to the localization nature of the defect-induced bands, the magnetic moment is mainly localized at the vacancy site. As for the monolayer graphyne with one single vacancy at the sp hybridized C site, one defect-induced state which is highly split appears in the band gap. The spin-up band of the defect-induced state is highly dispersive and shows considerable delocalization, suggesting that the magnetic moment is dispersed around the vacancy site. The above magnetization in monolayer graphyne with one single vacancy is possibly explained in terms of the valence-bond theory. - Graphical abstract: Calculated band structure of the monolayer graphyne without (a) and with one single vacancy at Vb site (b) and at Vr site(c), respectively. Blue and red lines represent the spin-up and spin-down bands, respectively. For the sake of clarity, the band structure near the Fermi energy is also presented on the right panel. The Fermi level is set to zero on the energy scale. - Highlights: • A Jahn-Teller distortion occurs in monolayer graphyne with single vacancy. • The spin polarization is sensitive to local geometric structure of the vacancy. • Vacancy lying at sp{sup 2} hybridized C site introduces weakly spin-polarized defect bands. • A strong spin splitting occurs when the vacancy lies at sp hybridized C site. • The magnetization is explained in terms of the valence-bond theory.

  14. Minimization of nonspecific binding to improve the sensitivity of a magnetic immunoradiometric assay (IRMA) for human thyrotropin (hTSH)

    International Nuclear Information System (INIS)

    Peroni, C.N.; Ribela, M.T.C.P.; Bartolini, P.

    1996-01-01

    An IRMA of hTSH, based on magnetic solid phase separation, was studied especially in terms of its nonspecific bindings (B 0 ). These were identified as a product of the interaction between radioiodinated anti-hTSH monoclonal antibody ( 125 I-mAB) and the uncoupled magnetizable cellulose particle (matrix). The negative effects of B 0 on the assay performance were minimized and practically eliminated, in the optimized system, with tracer storage at 4 deg. C, repurification and pre-incubation with the same matrix, serum addition during incubation and solid phase saturation with milk proteins. These findings were used in order to reproducibly decrease non specific binding to values 60 /B 0 ) into values of 300-500. This way, hTSH IRMAs were obtained with functional sensitivities of about 0.05 mlU/L and analytical sensitivities of the order of 0.02 mlU/L, which represent an approximate 10-fold increase in sensitivity when compared with non-optimized system. A more optimistic sensitivity calculation, based on Rodbard's definition, provided values down to 0.008 mlU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 10 refs, 1 fig., 8 tabs

  15. Understanding The Behavior Of The Sun'S Large Scale Magnetic Field And Its Relation With The Meridional Flow

    Science.gov (United States)

    Hazra, Gopal

    2018-02-01

    In this thesis, various studies leading to better understanding of the 11-year solar cycle and its theoretical modeling with the flux transport dynamo model are performed. Although this is primarily a theoretical thesis, there is a part dealing with the analysis of observational data. The various proxies of solar activity (e.g., sunspot number, sunspot area and 10.7 cm radio flux) from various observatory including the sunspot area records of Kodaikanal Observatory have been analyzed to study the irregular aspects of solar cycles and an analysis has been carried out on the correlation between the decay rate and the next cycle amplitude. The theoretical analysis starts with explaining how the magnetic buoyancy has been treated in the flux transport dynamo models, and advantages and disadvantages of different treatments. It is found that some of the irregular properties of the solar cycle in the decaying phase can only be well explained using a particular treatment of the magnetic buoyancy. Next, the behavior of the dynamo with the different spatial structures of the meridional flow based on recent helioseismology results has been studied. A theoretical model is constructed considering the back reaction due to the Lorentz force on the meridional flows which explains the observed variation of the meridional flow with the solar cycle. Finally, some results with 3D FTD models are presented. This 3D model is developed to handle the Babcock-Leighton mechanism and magnetic buoyancy more realistically than previous 2D models and can capture some important effects connected with the subduction of the magnetic field in polar regions, which are missed in 2D surface flux transport models. This 3D model is further used to study the evolution of the magnetic fields due to a turbulent non-axisymmetric velocity field and to compare the results with the results obtained by using a simple turbulent diffusivity coefficient.

  16. Development of magnetic jxB sensor

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Ishitsuka, Etsuo

    2001-12-01

    The improved mechanical sensor, i.e. magnetic jxB sensor (a mechanical sensor and a part of the steady state hybrid-type magnetic sensor) has been designed. The basic structure of the sensor is similar to the previously developed sensor (old sensor) in EDA phase. In this design, the neutron resistant materials are selected for the load cell (strain gauge and sensor beam) and sensing coil/frame. In order to reduce temperature drift of the sensor signal, four strain gauges with the same electrical property and geometrical size are bonded on the sensor beam by using Al 2 O 3 plasma spraying process, i.e., a couple of strain gauges is bonded on one side of the beam and another couple of gauges is bonded on the other side. These four strain gauges form an electrical bridge circuit. The zero-level drift of the output of the load cell used in the magnetic jxB sensor was reduced to about 1/20 compared with the old sensor. The temperature dependence of the output of the load cell is small. The linearity of the output of the load cell against weight was obtained. A non-linearity was observed in the sensitivity of the magnetic jxB sensor. The deviation of sensitivity from the fitting line was less than 7% in the high magnetic field region. The neutron irradiation effect on sensitivity of the sensor was investigated. The sensitivity of the sensor was gradually decreased by ∼30% at neutron fluence of (1.8-2.8)x10 23 n/m 2 in the high magnetic field. During irradiation, the non-linearity was observed in the sensitivity. (author)

  17. SENSITIVITY OF ENDOSCOPIC ULTRASOUND, MULTIDETECTOR COMPUTER TOMOGRAPHY AND MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY IN THE DIAGNOSIS OF PANCREAS DIVISUM: A TERTIARY CENTER EXPERIENCE

    Science.gov (United States)

    Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.

    2014-01-01

    OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [ppancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370

  18. Competing reaction channels in IR-laser-induced unimolecular reactions

    International Nuclear Information System (INIS)

    Berman, M.R.

    1981-01-01

    The competing reaction channels in the unimolecular decomposition of two molecules, formaldehyde and tetralin were studied. A TEA CO 2 laser was used as the excitation source in all experiments. The dissociation of D 2 CO was studied by infrared multiphoton dissociation (MPD) and the small-molecule nature of formaldehyde with regard to MPD was explored. The effect of collisions in MPD were probed by the pressure dependence of the MPD yield and ir fluorescence from multiphoton excited D 2 CO. MPD yield shows a near cubic dependence in pure D 2 CO which is reduced to a 1.7 power dependence when 15 torr of NO is added. The peak amplitude of 5 μm ir fluorescence from D 2 CO is proportional to the square of the D 2 CO pressure in pure D 2 CO or in the presence of 50 torr of Ar. Results are explained in terms of bottlenecks to excitation at the v = 1 level which are overcome by a combination of vibrational energy transfer and rotational relaxation. The radical/molecule branching ratio in D 2 CO MPD was 0.10 +- 0.02 at a fluence of 125 J/cm 2 at 946.0 cm -1 . The barrier height to molecular dissociation was calculated to be 3.6 +- 2.0 kcal/mole below the radical threshold or 85.0 +- 3.0 kcal/mole above the ground state of D 2 CO. In H 2 CO, this corresponds to 2.5 +- 2.0 kcal/mole below the radical threshold or 83.8 +- 3.0 kcal/mole above the ground state. Comparison with uv data indicate that RRKM theory is an acceptable description of formaldehyde dissociation in the 5 to 10 torr pressure range. The unimolecular decomposition of tetralin was studied by MPD and SiF 4 - sensitized pyrolysis. Both techniques induce decomposition without the interference of catalytic surfaces. Ethylene loss is identified as the lowest energy reaction channel. Dehydrogenation is found to result from step-wise H atom loss. Isomerization via disproportionation is also identified as a primary reaction channel

  19. Reward and Punishment Sensitivity in Children with ADHD: Validating the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for Children (SPSRQ-C)

    OpenAIRE

    Luman, Marjolein; van Meel, Catharina S.; Oosterlaan, Jaap; Geurts, Hilde M.

    2011-01-01

    This study validates the Sensitivity to Punishment and Sensitivity to Reward Questionnaire for children (SPSRQ-C), using a Dutch sample of 1234 children between 6-13 years old. Factor analysis determined that a 4-factor and a 5-factor solution were best fitting, explaining 41% and 50% of the variance respectively. The 4-factor model was highly similar to the original SPSRQ factors found in adults (Punishment Sensitivity, Reward Responsivity, Impulsivity/ Fun-Seeking, and Drive). The 5-factor ...

  20. Stellarator Coil Design and Plasma Sensitivity

    International Nuclear Information System (INIS)

    Ku, Long-Poe; Boozer, Allen H.

    2010-01-01

    The rich information contained in the plasma response to external magnetic perturbations can be used to help design stellarator coils more effectively. We demonstrate the feasibility by first devel oping a simple, direct method to study perturbations in stellarators that do not break stellarator symmetry and periodicity. The method applies a small perturbation to the plasma boundary and evaluates the resulting perturbed free-boundary equilibrium to build up a sensitivity matrix for the important physics attributes of the underlying configuration. Using this sensitivity information, design methods for better stellarator coils are then developed. The procedure and a proof-of-principle application are given that (1) determine the spatial distributions of external normal magnetic field at the location of the unperturbed plasma boundary to which the plasma properties are most sen- sitive, (2) determine the distributions of external normal magnetic field that can be produced most efficiently by distant coils, (3) choose the ratios of the magnitudes of the the efficiently produced magnetic distributions so the sensitive plasma properties can be controlled. Using these methods, sets of modular coils are found for the National Compact Stellarator Experiment (NCSX) that are either smoother or can be located much farther from the plasma boundary than those of the present design.

  1. Simply synthesized TiO2 nanorods as an effective scattering layer for quantum dot sensitized solar cells

    International Nuclear Information System (INIS)

    Samadpour, Mahmoud; Zad, Azam Iraji; Molaei, Mehdi

    2014-01-01

    TiO 2 nanorod layers are synthesized by simple chemical oxidation of Ti substrates. Diffuse reflectance spectroscopy measurements show effective light scattering properties originating from nanorods with length scales on the order of one micron. The films are sensitized with CdSe quantum dots (QDs) by successive ionic layer adsorption and reaction (SILAR) and integrated as a photoanode in quantum dot sensitized solar cells (QDSCs). Incorporating nanorods in photoanode structures provided 4- to 8-fold enhancement in light scattering, which leads to a high power conversion efficiency, 3.03% (V oc = 497 mV, J sc = 11.32 mA/cm 2 , FF = 0.54), in optimized structures. High efficiency can be obtained just by tuning the photoanode structure without further treatments, which will make this system a promising nanostructure for efficient quantum dot sensitized solar cells. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  2. Development of a Tandem Repeat-Based Polymerase Chain Displacement Reaction Method for Highly Sensitive Detection of 'Candidatus Liberibacter asiaticus'.

    Science.gov (United States)

    Lou, Binghai; Song, Yaqin; RoyChowdhury, Moytri; Deng, Chongling; Niu, Ying; Fan, Qijun; Tang, Yan; Zhou, Changyong

    2018-02-01

    Huanglongbing (HLB) is one of the most destructive diseases in citrus production worldwide. Early detection of HLB pathogens can facilitate timely removal of infected citrus trees in the field. However, low titer and uneven distribution of HLB pathogens in host plants make reliable detection challenging. Therefore, the development of effective detection methods with high sensitivity is imperative. This study reports the development of a novel method, tandem repeat-based polymerase chain displacement reaction (TR-PCDR), for the detection of 'Candidatus Liberibacter asiaticus', a widely distributed HLB-associated bacterium. A uniquely designed primer set (TR2-PCDR-F/TR2-PCDR-1R) and a thermostable Taq DNA polymerase mutant with strand displacement activity were used for TR-PCDR amplification. Performed in a regular thermal cycler, TR-PCDR could produce more than two amplicons after each amplification cycle. Sensitivity of the developed TR-PCDR was 10 copies of target DNA fragment. The sensitive level was proven to be 100× higher than conventional PCR and similar to real-time PCR. Data from the detection of 'Ca. L. asiaticus' with filed samples using the above three methods also showed similar results. No false-positive TR-PCDR amplification was observed from healthy citrus samples and water controls. These results thereby illustrated that the developed TR-PCDR method can be applied to the reliable, highly sensitive, and cost-effective detection of 'Ca. L. asiaticus'.

  3. Magnetic Properties of NdAl2

    DEFF Research Database (Denmark)

    Bak, P.

    1974-01-01

    The magnetic properties of NdAl2 are calculated using a Hamiltonian including crystal-field and isotropic exchange interaction terms. A two-dimensional mean-field theory is evaluated to calculate single-crystal magnetization curves. It is shown that the magnetic properties can be understood using...... the crystal-field parameters derived from the magnetic exciton spectrum measured by Houmann et al. by means of inelastic neutron scattering. The combined lambda -Schottky anomaly in the heat capacity is explained. No additional parameters are introduced....

  4. Sensitivity of fusion and quasi-elastic barrier distributions of {sub 16}O+{sub 144}Sm reaction on the coupling radius parameter

    Energy Technology Data Exchange (ETDEWEB)

    Zamrun, Muhammad; Usman, Ida; Variani, Viska Inda [Department of Physics, Haluoleo University, Kendari, Sulawesi Tengagra, 93232 (Indonesia); Kassim, Hasan Abu [Department of Physics, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-03-05

    We study the heavy-ion collision at sub-barrier energies of {sub 16}O+{sub 144}Sm system using full order coupled-channels formalism. We especially investigate the sensitivity of fusion and quasi-elastic barrier distributions for this system on the coupling radius parameter. We found that the coupled-channels calculations of the fusion and the quasi-elastic barrier distributions are sensitive to the coupling radius for this reaction in contrast to the fusion and quasi-elastic cross section. Our study indicates that the larger coupling radius, i.e., r{sub coup}=1.20, is required by the experimental quasi-elastic barrier distribution. However, the experimental fusion barrier distribution compulsory the small value, i.e., r{sub coup}=1.06.

  5. Numerical simulation of bubble deformation in magnetic fluids by finite volume method

    International Nuclear Information System (INIS)

    Yamasaki, Haruhiko; Yamaguchi, Hiroshi

    2017-01-01

    Bubble deformation in magnetic fluids under magnetic field is investigated numerically by an interface capturing method. The numerical method consists of a coupled level-set and VOF (Volume of Fluid) method, combined with conservation CIP (Constrained Interpolation Profile) method with the self-correcting procedure. In the present study considering actual physical properties of magnetic fluid, bubble deformation under given uniform magnetic field is analyzed for internal magnetic field passing through a magnetic gaseous and liquid phase interface. The numerical results explain the mechanism of bubble deformation under presence of given magnetic field. - Highlights: • A magnetic field analysis is developed to simulate the bubble dynamics in magnetic fluid with two-phase interface. • The elongation of bubble increased with increasing magnetic flux intensities due to strong magnetic normal force. • Proposed technique explains the bubble dynamics, taking into account of the continuity of the magnetic flux density.

  6. Sustainable Utility of Magnetically Recyclable Nano-Catalysts in Water: Applications in Organic Synthesis

    Directory of Open Access Journals (Sweden)

    Manoj B. Gawande

    2013-10-01

    Full Text Available Magnetically recyclable nano-catalysts and their use in aqueous media is a perfect combination for the development of greener sustainable methodologies in organic synthesis. It is well established that magnetically separable nano-catalysts avoid waste of catalysts or reagents and it is possible to recover >95% of catalysts, which is again recyclable for subsequent use. Water is the ideal medium to perform the chemical reactions with magnetically recyclable nano-catalysts, as this combination adds tremendous value to the overall benign reaction process development. In this review, we highlight recent developments inthe use of water and magnetically recyclable nano-catalysts (W-MRNs for a variety of organic reactions namely hydrogenation, condensation, oxidation, and Suzuki–Miyaura cross-coupling reactions, among others.

  7. Study of some continuous spectra produced by nuclear reactions with light nuclei

    International Nuclear Information System (INIS)

    Marquez, L.

    1966-01-01

    The continuous spectra coming from several nuclear reactions with light nuclei were measured. The spectra can be explained by a two-step reaction mechanism; however, the reactions produced by 6 Li are different. A mechanism was proposed to explain their spectra based on the following assumptions: 6 Li makes a nuclear molecule with the target which subsequently breaks up in such a way that an α particle comes out with the kinetic energy that it has in the molecule. The calculated spectra and those measured are in good agreement. (author) [fr

  8. Plasma fluctuations and confinement of fusion reaction products

    International Nuclear Information System (INIS)

    Coppi, B.; Pegoraro, F.

    1981-01-01

    The interaction between the fluctuations that can be excited in a magnetically confined plasma and the high-energy-particle population produced by fusion reactions is analyzed in view of its relevance to the process of thermonuclear ignition. The spectrum of the perturbations that, in the absence of fusion reaction products, would be described by the incompressible ideal magnetohydrodynamic approximation is studied considering finite value of the plasma pressure relative ot the magnetic pressure. The combined effects of the magnetic field curvature and shear are taken into account and the relevant spectrum is shown to consist of a continuous portion, that could be identified as a mixture of shear-Alfven and interchange oscillations, and a discrete unstable part corresponding to the so-called ballooning modes. The rate of diffusion of the fusion reaction products induced by oscillations in the continuous part of the spectrum, as estimated from the appropriate quasi-linear theory, is found to be significantly smaller than could be expected if normal modes (i.e., nonconvective solutions) were excited. However, a relatively wide intermediate region is identified where opalescent fluctuations, capable of achieving significant amplitudes and corresponding to a quasi-discrete spectrum, can be excited

  9. Theme of the Workshop on Itinerant-Electron Magnetism, and Spin Fluctuations

    Science.gov (United States)

    Yoshimura, Kazuyoshi

    2017-06-01

    The international workshop on itinerant-electron magnetism was held during September 25-27, 2015 in the seminar house of Graduate School of Science, Kyoto University, Kyoto, Japan. Here, I explain the theme of this workshop, and stress the development of itinerant-electron magnetism in several decades. The workshop was also organized in commemoration of Professor Yoshinori Takahashi’s retirement from University of Hyogo, Japan. Here, I also explain some of his works contributing to the development of itinerant magnetism.

  10. Investigation of magnetic fluids exhibiting field-induced increasing loss peaks

    International Nuclear Information System (INIS)

    Fannin, P.C.; Marin, C.N.; Couper, C.

    2010-01-01

    A theoretical analysis to explain an increase of the Brownian loss peak with increasing polarizing field, H, in a magnetic fluid, is presented. The model is based on the competition between the Brownian and Neel relaxation processes. It is demonstrated that in magnetic fluids with particles having small anisotropy constant, small average magnetic diameter and narrow particle size distribution an increase of the Brownian loss peak with the polarizing field can be observed. The theoretical results are compared with the experimental results of an Isopar M-based magnetic fluid with magnetite particles stabilized with oleic acid and the model explains qualitatively the main characteristics of the experimental results.

  11. Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs

    Directory of Open Access Journals (Sweden)

    Eva Vargas

    2017-11-01

    Full Text Available This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs. The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21 with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs, and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA conjugated with an horseradish peroxidase (HRP homopolymer (Poly-HRP40 as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs using the H2O2/hydroquinone (HQ system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD of 10 attomoles (in a 25 μL sample without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared. This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt extracted from human mammary epithelial normal (MCF-10A and cancer (MCF-7 cells and tumor tissues.

  12. Magnetic performance of orthorhombic Mn{sub 35}Ge{sub 35}Te{sub 30} nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Mahdy, Iman A.

    2017-01-15

    Nanocrystalline antiferromagnetic Mn{sub 35}Ge{sub 35}Te{sub 30} diluted magnetic semiconductors powder syntheses by the conventional direct reaction of pure metals. Nanocrystalline nature of the prepared sample confirmed using various techniques, where x-Ray diffraction (XRD) and atomic force microscope (AFM) measurements shows ~96 nm particle size, while transmission electron microscope (TEM) shows 92 nm particle size. XRD analysis show orthorhombic symmetry with lattice parameters a=7.386611±(0.0066) Å, b=8.962502±(0.0090) Å and c=7.027349±(0.0040) Å. Electron Spin resonance (ESR) show a broad asymmetric line whereas the remnant Mn{sup 2+} six-hyperfine lines are broadened within |+1/2>→|−1/2> line according to high anisotropy; calculated Landé g-factor is 2.047. Vibrating sample magnetometer (VSM) analysis, field-moment characteristics revealed a hysteresis loop with small coercive field indicating that Mn{sub 35}Ge{sub 35}Te{sub 30} is a soft magnetic material. Moreover, hysteresis measurements at different temperatures show increasing magnetization with increasing temperature up to 150 K followed by decreased with increasing temperature up to 300 K. This behavior indicated to the antiferromagnetic nature of the prepared nanocrystalline materials. Magnetic moment – temperature measurements show Néel temperature T{sub N}=172.6 K. Magnetic force microscope revealed magnetic domains as a result of interaction between magnetic dipole moments of magnetic cantilever and pressed powder. - Highlights: • Nanocrystalline diluted magnetic semiconductors of new Mn-Ge-Te orthorhombic phase. • Soft magnetic materials for a magnetic core of many devices. • Mixture of ferromagnetic and antiferromagnetic. • Asymmetry in hysteresis loop explained by the exchange bias of domain spins.

  13. Measurement of the pp → dπ+ reaction at 793, 800 and 1920 MeV/c and fixing the transport matrix of the magnetic spectrometer Big Karl

    International Nuclear Information System (INIS)

    Razen, B.

    1997-12-01

    This work presents measurements of the pp → dπ + reaction at a beam momentum of 793 MeV/c and 801 MeV/c. Differential and total cross sections at these energies were measured with the magnetic spectrometer Big Karl, which grants a nearly 4π-acceptance in the center of mass system. A major emphasis is given to the deduction of the transfer-matrix of the magnetic system, which allows full momentum reconstruction of the deuterons at the target point. Anisotropies and partial wave contributions are deduced from these measurements. They suggest not negligible P-wave contribution already close to threshold. Comparing our data to the measurements of the isospin related reaction np → dπ 0 yields some difference, which might be a hint to some isospin-breaking. Finally a measurement at 1920 MeV/c beam momentum was done to calibrate the momentum of the external beam of COSY. (orig.)

  14. Application of the magnetic fluid as a detector for changing the magnetic field

    Science.gov (United States)

    Zyatkov, D.; Yurchenko, A.; Yurchenko, V.; Balashov, V.

    2018-05-01

    In article the possibility of use of magnetic fluid as a sensitive element for fixing of change of induction of magnetic field in space is considered. Importance of solvable tasks is connected with search of the perspective magnetic substances susceptible to weak magnetic field. The results of a study of the capacitive method for fixing the change in the magnetic field on the basis of a ferromagnetic liquid are presented. The formation of chain structures in the ferrofluid from magnetic particles under the influence of the applied magnetic field leads to a change in the capacitance of the plate condenser. This task has important practical value for development of a magnetosensitive sensor of change of magnetic field.

  15. Study on the Attitude Control of Spacecraft Using Reaction Wheels

    Directory of Open Access Journals (Sweden)

    Ju-Young Du

    1998-06-01

    Full Text Available Attitude determination and control of satellite is important component which determines the accomplish satellite missions. In this study, attitude control using reaction wheels and momentum dumping of wheels are considered. Attitude control law is designed by Sliding control and LQR. Attitude maneuver control law is obtained by Shooting method. Wheels momentum dumping control law is designed by Bang-Bang control. Four reaction wheels are configurated for minimized the electric power consumption. Wheels control torque and magnetic moment of magnetic torquer are limited.

  16. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  17. Noise sensitivity and reactions to noise and other environmental conditions

    NARCIS (Netherlands)

    Miedema, H.M.E.; Vos, H.

    2003-01-01

    This article integrates findings from the literature and new results regarding noise sensitivity. The new results are based on analyses of 28 combined datasets (N=23 038), and separate analyses of a large aircraft noise study (N=10939). Three topics regarding noise sensitivity are discussed, namely,

  18. Measurement of the torque on diluted ferrofluid samples in rotating magnetic fields

    International Nuclear Information System (INIS)

    Storozhenko, A.M.; Stannarius, R.; Tantsyura, A.O.; Shabanova, I.A.

    2017-01-01

    We study magnetic suspensions with different concentrations of ferromagnetic nanoparticles in a spherical container under the action of a rotating magnetic field. Experimental data on the concentration dependence of the rotational effect, viz. the torque exerted by the magnetic field, are presented. We explain the observed torque characteristics using a model that takes into account field-driven aggregation of the magnetic nanoparticles in stationary or slowly rotating fields. At sufficiently high rotation rates, the rotating magnetic field obviously destroys these aggregates, which results in a decreasing torque with increasing rotation frequency of the field. - Highlights: • The experimental study of the rotational effect in the magnetic fluids is presented. • The torque density non-monotonously depends on the magnetic field frequency. • Experimental data can be explained assuming aggregation of magnetic nanoparticles.

  19. Measurement of the torque on diluted ferrofluid samples in rotating magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Storozhenko, A.M. [Southwest State University, Kursk, 305040 (Russian Federation); Stannarius, R. [Otto von Guericke University Magdeburg, Magdeburg, 39016 Germany (Germany); Tantsyura, A.O.; Shabanova, I.A. [Southwest State University, Kursk, 305040 (Russian Federation)

    2017-06-01

    We study magnetic suspensions with different concentrations of ferromagnetic nanoparticles in a spherical container under the action of a rotating magnetic field. Experimental data on the concentration dependence of the rotational effect, viz. the torque exerted by the magnetic field, are presented. We explain the observed torque characteristics using a model that takes into account field-driven aggregation of the magnetic nanoparticles in stationary or slowly rotating fields. At sufficiently high rotation rates, the rotating magnetic field obviously destroys these aggregates, which results in a decreasing torque with increasing rotation frequency of the field. - Highlights: • The experimental study of the rotational effect in the magnetic fluids is presented. • The torque density non-monotonously depends on the magnetic field frequency. • Experimental data can be explained assuming aggregation of magnetic nanoparticles.

  20. Orientation Sensitivity of Oxygen Evolution Reaction on Hematite

    NARCIS (Netherlands)

    Zhang, X. Q.; Cao, C.; Bieberle, A.

    2016-01-01

    The sensitivity of the surface orientation on photoelectrochemical water oxidation has recently been reported by experimental studies. However, a detailed theoretical understanding is still missing. Density functional theory + Hubbard U (DFT + U) calculations are therefore carried out in order to