  1. BPA and BSH accumulation in experimental tumors

    International Nuclear Information System (INIS)

    Patel, H.; Sedgwick, E.M.

    2000-01-01

    The accumulation of boronated compounds into tumors is a critical component to the success of BNCT. To date, great variability has been demonstrated in the tumor:blood ratio achieved in samples both from different patients and within samples taken from the same patient. The factors that probably influence the level of uptake include the vascular perfusion within the tumor, the permeability of these vessels and the viability of the tumor cells themselves. These experiments were designed to measure these various factors in different experimental tumor models and to relate these measurements to the uptake of both BPA (Boronophenylalanine) and BSH (Sodiumborocaptate). They demonstrate that within different tumors there can be wide variations in the vascular parameters. In addition, the viability of the tumor cells may also be an important determinant of tumor uptake. (author)

  2. Experimental tumor therapy

    International Nuclear Information System (INIS)

    1982-06-01

    This is a report on the work of the joint research group of the Institute of Radiation Biology (Strahlenbiologisches Institut) of the university of Munich and the Department of Radiation Biology of the Society for Radiation and Environmental Research (Gesellschaft fuer Strahlen- u. Umweltforschung - GSF -) at Neuherberg. The presented results are not in all cases definitely confirmed or have, in part, merely provisional character. It is the target of the joint research to investigate problems of cancer therapy of practical impact in model form and to develop recommendations in discussions with therapists. Thus, the aim is not so much to examine mechanisms of action of certain radiations in detail but to look for the general rules they are governed by and to analyze the quantitative aspects of cancer therapy. To achieve this, a great variety of test models must be at hand. Numerous cell cultivies and tumors of mice resp. rats are therefore used. The acute reactions to irradiation are examined on the skin, the small intestine crypts, the bone marrow and spleen colonies of mice and the chronic reactions are tested on the colon and heart of rats and on the vascular connective tissue and kidneys of mice. (orig./MG) [de

  3. Experimental tumor therapy

    International Nuclear Information System (INIS)

    1980-01-01

    This study was concentrated on the investigation of practically oriented problems of tumour therapy, under the application of possibly differing experimental test subjects, ranging from cell cultures to the living animal. The development of the test systems was advanced and some systems were replaced by new ones. An enrichment of great significance is also the fibrosarcoma SSK-2 of the C3H mouse, whose cells form colonies with an exploitation of about 50% when the explant is transferred directly to the cell culture. The subject matter of the experiments ranged from the effect of irradiation on cells in vitro to the proliferation kinetics of human tumours under treatment. As in the last year the main significance and attention was attributed to the analysis of time dependency in radiotherapy. The second main point were investigations on the interaction of chemotherapy and radiotherapy, supplemented by experiments to the time dependency in chemotherapy. (orig./MG) [de

  4. Hypoxyradiotherapy: lack of experimental evidence for a preferential radioprotective effect on normal versus tumor tissue as shown by direct oxygenation measurements in experimental sarcomas

    International Nuclear Information System (INIS)

    Kelleher, Debra K.; Thews, Oliver; Vaupel, Peter

    1997-01-01

    Aim: In order to investigate possible pathophysiological mechanisms underlying the postulated preferential protective effect of hypoxia on normal tissue during radiotherapy, the impact of acute respiratory hypoxia (8.2% O 2 + 91.8% N 2 ) on tissue oxygenation was assessed. Methods: Tumor and normal tissue oxygenation was directly determined using O 2 -sensitive electrodes in two experimental rat tumors (DS and Yoshida sarcomas) and in the normal subcutis of the hind foot dorsum. Results: During respiratory hypoxia, arterial blood O 2 tension (pO 2 ), oxyhemoglobin saturation and mean arterial blood pressure decreased. Changes in the arterial blood gas status were accompanied by a reflex hyperventilation leading to hypocapnia and respiratory alkalosis. In the subcutis, tissue oxygenation worsened during acute hypoxia, with decreases in the mean and median pO 2 . Significant increases in the hypoxic fractions were, however, not seen. In tumor tissues, oxygenation also worsened upon hypoxic hypoxia with significant decreases in the mean and median pO 2 and increases in the size of the hypoxic fractions for both sarcomas. Conclusion: These results suggest that during respiratory hypoxia, radiobiologically relevant reductions in the oxygenation (and a subsequent selective radioprotection) of normal tissue may not be achieved. In addition, in the tumor models studied, a worsening of tumor oxygenation was seen which could result in an increased radioresistance

  5. Experimental tumor therapy - annual report 1982

    International Nuclear Information System (INIS)

    1983-08-01

    The present annual report is the fifth in a regular series and documents the continuity of the investigations in the field of experimental tumor therapy. The main points of emphasis of the activities relate above all to problems of dose fractionation and combination treatment. But if the present volume is compared with the previous ones the reader may be struck by the wider range of model systems used, especially of the tumors and normal tissues in which chronic radiation effects are investigated, and also by a concentration on those investigations that are important for solving clinical problems and that make use of many small fractions. Moreover, experiments were carried through in 1982 on the neutron beam set up at the Garching research reactor in order to characterise its biologic effect, which was a preparative measure in view of the planned clinical use. (orig./MG) [de

  6. Experimental rat lung tumor model with intrabronchial tumor cell implantation.

    Science.gov (United States)

    Gomes Neto, Antero; Simão, Antônio Felipe Leite; Miranda, Samuel de Paula; Mourão, Lívia Talita Cajaseiras; Bezerra, Nilfácio Prado; Almeida, Paulo Roberto Carvalho de; Ribeiro, Ronaldo de Albuquerque

    2008-01-01

    The objective of this study was to develop a rat lung tumor model for anticancer drug testing. Sixty-two female Wistar rats weighing 208 +/- 20 g were anesthetized intraperitoneally with 2.5% tribromoethanol (1 ml/100 g live weight), tracheotomized and intubated with an ultrafine catheter for inoculation with Walker's tumor cells. In the first step of the experiment, a technique was established for intrabronchial implantation of 10(5) to 5 x 10(5) tumor cells, and the tumor take rate was determined. The second stage consisted of determining tumor volume, correlating findings from high-resolution computed tomography (HRCT) with findings from necropsia and determining time of survival. The tumor take rate was 94.7% for implants with 4 x 10(5) tumor cells, HRCT and necropsia findings matched closely (r=0.953; p<0.0001), the median time of survival was 11 days, and surgical mortality was 4.8%. The present rat lung tumor model was shown to be feasible: the take rate was high, surgical mortality was negligible and the procedure was simple to perform and easily reproduced. HRCT was found to be a highly accurate tool for tumor diagnosis, localization and measurement and may be recommended for monitoring tumor growth in this model.

  7. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  8. Experimental research for tumor VIP receptor imaging

    International Nuclear Information System (INIS)

    Li Qianwei; Tan Tianzhi

    1998-01-01

    To study the possibility of radioactive labelled vasoactive intestinal peptide (VIP) for tumor VIP receptor imaging. 125 I-VIP was prepared by chloramine-T method, and purified by Sephadex G-50 column chromatography. The bioactivity and stability of 125 I-VIP were measured by silica 60 F 254 TLC and competition test to SGC7901 cell in vitro. The biodistribution of 125 I-VIP was studied in the nude mice bearing tumor. The results showed that labelled rate of 125 I was 73.8%, the specific activity was 18.2 PBq/mol, the radiochemical purity (RCP) was over 98% and remained 96.3% after 48 days stored at -80 degree C. The specific binding of 125 I-VIP to the SGC7901 cell was inhibited by VIP in dose dependence in the competition experiment. The radioactivity of tumor was higher than that of muscles in all phases (P<0.05-0.01), the peak activity of tumor occurred at 30 min (3.58 +- 0.48ID%/g) and the peak ratio of T/N occurred at 60 min after the injection. The activity of lungs was obviously higher than that of blood, the intestine was always in low level. Most of the activity in the body was mainly eliminated from kidney. The present study demonstrated that the radioactive labelled VIP is a promising agent for tumor VIP receptor scintigraphy

  9. The Impact of Environmental Light Intensity on Experimental Tumor Growth.

    Science.gov (United States)

    Suckow, Mark A; Wolter, William R; Duffield, Giles E

    2017-09-01

    Cancer research requires for consistent models that minimize environmental variables. Within the typical laboratory animal housing facility, animals may be exposed to varying intensities of light as a result of cage type, cage position, light source, and other factors; however, studies evaluating the differential effect of light intensity during the light phase on tumor growth are lacking. The effect of cage face light intensity, as determined by cage rack position was evaluated with two tumor models using the C57Bl/6NHsd mouse and transplantable B16F10 melanoma cells or Lewis lung carcinoma (LLC) cells. Animals were housed in individually-ventilated cages placed at the top, middle, or bottom of the rack in a diagonal pattern so that the top cage was closest to the ceiling light source, and cage face light intensity was measured. Following a two-week acclimation period at the assigned cage position, animals were subcutaneously administered either 1.3×10 6 B16F10 melanoma cells or 2.5×10 5 Lewis lung carcinoma cells. Weights of excised tumors were measured following euthanasia 18 days (melanoma) or 21 days (LCC) after tumor cell administration. Cage face light intensity was significantly different depending on the location of the cage, with cages closest to the light source have the greatest intensity. Mean tumor weights were significantly less (plight intensity mice compared to high and low light intensity mice. The environmental light intensity to which experimental animals are exposed may vary markedly with cage location and can significantly influence experimental tumor growth, thus supporting the idea that light intensity should be controlled as an experimental variable for animals used in cancer research. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. A fundamental study of dynamic CT for hemodynamics in experimental hepatic tumors

    International Nuclear Information System (INIS)

    Yamakawa, Fumiko

    1991-01-01

    Dynamic CT was performed using iodamide meglumine (2 ml/kg) to investigate hemodynamics in experimental hepatic tumors, tumor margins and in normal hepatic tissue as well in rabbits with VX 2 -induced hepatic tumors. Peak time (PT) and first moment (M1) were calculated from a time density curve prepared by eight consecutive 3-second scans over a period of 55 seconds. PT and M1 in tumors were significantly shorter than those in tumor margins and normal tissue, but were not influenced by tumor size. PT and M1 in tumor margins and normal tissue became longer with enlargement of the tumor. Ligation of the hepatic artery caused (1) no change in PT or M1 in normal tissue and tumor margins and (2) difficulty in measuring PT and M1 in tumors. Ligation of the portal vein caused (1) difficulty in measuring PT and M1 in normal tissue and tumor margins and (2) no change in PT or M1 in tumors. Pathological studies of specimens taken from each region of interest (ROI) showed that hemodynamics in the tumors reflected tumor-specific vascular structures. (author)

  11. MEASUREMENT AND PRECISION, EXPERIMENTAL VERSION.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    THIS DOCUMENT IS AN EXPERIMENTAL VERSION OF A PROGRAMED TEXT ON MEASUREMENT AND PRECISION. PART I CONTAINS 24 FRAMES DEALING WITH PRECISION AND SIGNIFICANT FIGURES ENCOUNTERED IN VARIOUS MATHEMATICAL COMPUTATIONS AND MEASUREMENTS. PART II BEGINS WITH A BRIEF SECTION ON EXPERIMENTAL DATA, COVERING SUCH POINTS AS (1) ESTABLISHING THE ZERO POINT, (2)…

  12. Oxygen tension measurements of tumors growing in mice

    International Nuclear Information System (INIS)

    Adam, Markus F.; Dorie, Mary Jo; Brown, J. Martin

    1999-01-01

    Purpose: Clinical studies using the Eppendorf histograph have shown that patients whose tumors have a low pO 2 have worse local control after radiotherapy, and have higher metastatic rates. Because preclinical studies of methods of overcoming, or exploiting, hypoxia generally use transplanted tumors in mice, we have compared the oxygenation of mouse tumors with human tumors to determine the appropriateness of the transplanted mouse model for such preclinical studies. Methods and Materials: We evaluated the oxygenation status of subcutaneous (s.c.) tissue and of 12 intradermally (i.d.)- and 7 s.c.-growing mouse or human transplanted tumors in mice using the Eppendorf histograph, and compared the values obtained with measurements of human head and neck nodes. Results: The normal tissue pO 2 profile of air-breathing mice showed a nearly Gaussian distribution (38.2 ± 14.9 mmHg). Breathing 10% O 2 or carbogen resulted in dramatic changes in normal tissue oxygenation. Tumors growing intradermally in the back of air-breathing mice were extremely hypoxic and resistant to expected changes in oxygenation (carbogen breathing, size, and use of anesthetics). Tumors growing s.c. in the foot showed higher oxygen profiles with marked changes in oxygenation when exposing the animals to different levels of oxygen. However, the oxygenation of the mouse tumors transplanted in either site was only a fraction of that of the majority of human tumors. Conclusion: Experimental mouse tumors are markedly hypoxic, with median values of 10-20% of those of human tumors. Hence, mouse tumors are probably good models for the most hypoxic human tumors that respond poorly to radiotherapy; however, caution has to be exercised in extrapolating data from mouse to man

  13. Localization of the experimental tumor regrowth after irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yamaura, H; Matsuzawa, T [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis and Cancer

    1978-08-01

    The process of the structural changes in the irradiated AH109A tumor and its regrowth was studied, using histologic and transparent-chamber techniques. The tumor tissue was divided into four successive layers, according to vascular morphology and measures. The vascularity was the greatest in the outermost region and decreased towards the inner part of the tumor until necrosis. The tumor was irradiated with various doses of x and gamma-rays. The inside hypoxic region was destroyed completely after 3,000 rad and regrowths started from the outermost area of the tumor where oxygen enhancing effect to irradiation was supposed to be the greatest.

  14. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  15. Effects of low dose mitomycin C on experimental tumor radiotherapy

    International Nuclear Information System (INIS)

    Yang Jianzheng; Liang Shuo; Qu Yaqin; Pu Chunji; Zhang Haiying; Wu Zhenfeng; Wang Xianli

    2001-01-01

    Objective: To evaluate the possibility of low dose mitomycin C(MMC) as an adjunct therapy for radiotherapy. Methods: Change in tumor size tumor-bearing mice was measured. Radioimmunoassay was used to determine immune function of mice. Results: Low dose Mac's pretreatment reduced tumor size more markedly than did radiotherapy only. The immune function in mice given with low dose MMC 12h before radiotherapy was obviously higher than that in mice subjected to radiotherapy only (P<0.05), and was close to that in the tumor-bearing mice before radiotherapy. Conclusion: Low dose MMC could improve the radiotherapy effect. Pretreatment with low dose MMC could obviously improve the immune suppression state in mice caused by radiotherapy. The mechanism of its improvement of radiotherapeutic effect by low dose of MMC might be due to its enhancement of immune function and induction of adaptive response in tumor-bearing mice

  16. Modelo experimental de tumor de Walker Walker’s tumoral experimental model

    Directory of Open Access Journals (Sweden)

    Sandra Pedroso de Moraes

    2000-12-01

    Full Text Available Com o objetivo de padronizar normas técnicas para obtenção de modelo animal com tumor de Walker 256 e de estabelecer o número de células tumorais necessárias para que esse tumor tenha grande porcentagem de pega e longevidade, possibilitando o desenvolvimento de pesquisas em várias áreas da saúde, foi realizado trabalho em duas etapas. Na primeira foram utilizados 120 ratos para treinamento e definição da técnica. Na segunda etapa foram utilizados 84 ratos, sendo estes separados em 7 grupos (G de 12 animais cada. O tumor, na forma ascítica, foi inoculado no tecido celular subcutâneo do dorso dos ratos com os seguintes números de células: GI, 1 x 10(7; GII, 5 x 10(6; GIII, 2,5 x 10(6; GIV, 1 x 10(6; GV, 5 x 10(5; GVI, 3 x 10(5 e GVII, 2 x 10(5. Foram avaliadas a porcentagem de pega e a longevidade nos grupos. Os animais dos GI, GII, GIII e GIV obtiveram 100% de desenvolvimento tumoral, porém baixa longevidade. Os dos GV e GVI obtiveram desenvolvimento tumoral em frequência maior que 90% e longevidade satisfatória. Os do GVII não apresentaram desenvolvimento tumoral. Concluiu-se que todos os procedimentos devem ser exaustivamente treinados e que o número de células tumorais viáveis para inoculação, em tecido celular subcutâneo de ratos, deve estar na faixa entre 5 x 10(5 e 3 x 10(5.The aim of this work was standardize technical norms to obtain a model of Walker 256 tumor in animals and get the tumorous cells number needed to increase the tumorous join percentage and longevity, it makes possible the research development in several health areas. The work was realized in two stages. In first were used 120 rats to crew’s training and technicals definitions. In second stage were used 84 rats, these separated in 7 groups (G with 12 animals each one. The tumor, in ascitic form was inoculated on subcutaneous cellular tissue on dorsal of rats with the follow number of cells : GI, 1 x 10(7; GII, 5 x 10(6; GIII, 2,5 x 10(6; GIV, 1

  17. Experimental model of ultrasound thermotherapy in rats inoculated with Walker-236 tumor Modelo experimental de termoterapia ultrassônica em ratos inoculados com tumor de Walker-236

    Directory of Open Access Journals (Sweden)

    José Antonio Carlos Otaviano David Morano

    2011-01-01

    Full Text Available PURPOSE: To develop a model to evaluate the effects of focal pulsed ultrasound (US waves as a source of heat for treatment of murine subcutaneous implanted Walker tumor. METHODS: An experimental, controlled, comparative study was conducted. Twenty male Wistar rats (160-300 g randomized in 2 equal groups (G-1: Control and G-2: Hyperthermia were inoculated with Walker-256 carcinosarcoma tumor. After 5 days G-2 rats were submitted to 45ºC hyperthermia. Heat was delivered directly to the tumor by an ultrasound (US equipment (3 MHz frequency, 1,5W/cm³. Tumor temperature reached 45º C in 3 minutes and was maintained at this level for 5 minutes. Tumor volume was measured on days 5, 8, 11, 14 e 17 post inoculation in both groups. Unpaired t-test was used for comparison. POBJETIVO: Desenvolver um modelo para avaliar os efeitos do ultra-som focal pulsado como fonte de calor para o tratamento de tumores de Walker subcutâneos implantados em ratos. MÉTODOS: Um estudo experimental, controlado, comparativo foi realizado. Vinte ratos Wistar machos (160-300 g divididos em dois grupos (G-1: Controle e G-2: hipertermia foram inoculados com tumor de Walker carcinossarcoma-256. Após cinco dias os ratos do grupo G-2 ratos foram submetidos a hipertermia (45ºC. O calor foi aplicado diretamente no tumor por um equipamento de ultrassonografia (3 MHz, 1,5 W/cm³. A temperatura no tumor atingiu 45ºC em 3 minutos e foi mantida nesse nível por 5 minutos. O volume do tumor foi medido nos dias 5, 8, 11, 14 e 17 após a inoculação, em ambos os grupos. Teste t não pareado foi utilizado para comparação. P <0,05 foi considerado significante. RESULTADOS: O volume do tumor foi significativamente maior no 5º dia e diminuiu nos dias 11, 14 e 17 nos ratos tratados. Animais submetidos à hipertermia sobreviveram mais tempo que os animais do grupo controle. No 29º dia após a inoculação do tumor, 40% dos ratos do grupo controle e 77,78% dos ratos tratados com

  18. Photoacoustic imaging to assess pixel-based sO2 distributions in experimental prostate tumors.

    Science.gov (United States)

    Bendinger, Alina L; Glowa, Christin; Peter, Jörg; Karger, Christian P

    2018-03-01

    A protocol for photoacoustic imaging (PAI) has been developed to assess pixel-based oxygen saturation (sO2) distributions of experimental tumor models. The protocol was applied to evaluate the dependence of PAI results on measurement settings, reproducibility of PAI, and for the characterization of the oxygenation status of experimental prostate tumor sublines (Dunning R3327-H, -HI, -AT1) implanted subcutaneously in male Copenhagen rats. The three-dimensional (3-D) PA data employing two wavelengths were used to estimate sO2 distributions. If the PA signal was sufficiently strong, the distributions were independent from signal gain, threshold, and positioning of animals. Reproducibility of sO2 distributions with respect to shape and median values was demonstrated over several days. The three tumor sublines were characterized by the shapes of their sO2 distributions and their temporal response after external changes of the oxygen supply (100% O2 or air breathing and clamping of tumor-supplying artery). The established protocol showed to be suitable for detecting temporal changes in tumor oxygenation as well as differences in oxygenation between tumor sublines. PA results were in accordance with histology for hypoxia, perfusion, and vasculature. The presented protocol for the assessment of pixel-based sO2 distributions provides more detailed information as compared to conventional region-of-interest-based analysis of PAI, especially with respect to the detection of temporal changes and tumor heterogeneity. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  19. Photoacoustic imaging to assess pixel-based sO2 distributions in experimental prostate tumors

    Science.gov (United States)

    Bendinger, Alina L.; Glowa, Christin; Peter, Jörg; Karger, Christian P.

    2018-03-01

    A protocol for photoacoustic imaging (PAI) has been developed to assess pixel-based oxygen saturation (sO2) distributions of experimental tumor models. The protocol was applied to evaluate the dependence of PAI results on measurement settings, reproducibility of PAI, and for the characterization of the oxygenation status of experimental prostate tumor sublines (Dunning R3327-H, -HI, -AT1) implanted subcutaneously in male Copenhagen rats. The three-dimensional (3-D) PA data employing two wavelengths were used to estimate sO2 distributions. If the PA signal was sufficiently strong, the distributions were independent from signal gain, threshold, and positioning of animals. Reproducibility of sO2 distributions with respect to shape and median values was demonstrated over several days. The three tumor sublines were characterized by the shapes of their sO2 distributions and their temporal response after external changes of the oxygen supply (100% O2 or air breathing and clamping of tumor-supplying artery). The established protocol showed to be suitable for detecting temporal changes in tumor oxygenation as well as differences in oxygenation between tumor sublines. PA results were in accordance with histology for hypoxia, perfusion, and vasculature. The presented protocol for the assessment of pixel-based sO2 distributions provides more detailed information as compared to conventional region-of-interest-based analysis of PAI, especially with respect to the detection of temporal changes and tumor heterogeneity.

  20. Should direct measurements of tumor oxygenation relate to the radiobiological hypoxic fraction of a tumor?

    International Nuclear Information System (INIS)

    Fenton, Bruce M.; Kiani, Mohammad F.; Siemann, Dietmar W.

    1995-01-01

    Purpose: Numerous previous studies have attempted to relate the radiobiological hypoxic fraction (HF) to direct measures of tumor oxygenation such as HbO 2 saturations, tumor pO 2 levels, or hypoxic cell labeling. Although correlations have been found within tumor lines, no overall relationships were seen across tumor lines. The current objective was to examine the effect on HF of changes in the fractions of the oxygenated and anoxic tumor cells that remain clonogenic. Methods and Materials: A mathematical model was developed that relates the HF to direct measures of tumor oxygenation. The primary assumptions were that: (a) the tumor is divided into distinct compartments of either fully oxygenated or fully anoxic cells, and (b) the survival of the oxygenated cells is negligible compared to that of the anoxic cells. Based on these assumptions, the HF is plotted as a function of the fractions of clonogenic or nonclonogenic, and oxygenated or anoxic cells. Results: If all cells are clonogenic, then the HF equals the fraction of anoxic cells. If a higher fraction of anoxic than oxygenated cells are nonclonogenic, then the HF will be overestimated by the fraction of the tumor measured to be anoxic using direct measuring techniques. If a higher fraction of the oxygenated than anoxic cells are nonclonogenic, the HF will be underestimated by the fraction of anoxic cells. Conclusion: Correlations between the HF and direct measures of tumor oxygenation have been described within tumor lines evaluated under different physiological condition. However, such relationships can be totally unpredictable between different tumors if the fraction of the anoxic cells that is clonogenic varies substantially. Clearly, if tumor anoxia cannot be detected using direct measures, this is an accurate indication that the tumor is well oxygenated. When tumor anoxia is present, however, the conclusions are ambiguous. Even when a small fraction of the tumor is measured as anoxic, direct measures

  1. Regional cerebral blood flow measurement in brain tumors

    International Nuclear Information System (INIS)

    Izunaga, Hiroshi; Hirota, Yoshihisa; Takahashi, Mutsumasa; Fuwa, Isao; Kodama, Takafumi; Matsukado, Yasuhiko

    1986-01-01

    The regional cerebral blood flow (CBF) was determined on seventeen patients with brain tumors. Ring type single photon emission CT (SPECT) was used following intravenous injection of 133 Xe. Case materials included eleven meningiomas and six malignant gliomas. Evaluation was performed with emphasis on the following points; 1. Correlation of the flow data within tumors to the angiographic tumor stains, 2. Influence of tumors on the cerebral blood flow of the normal brain tissue, 3. Correlation between degree of peripheral edema and the flow data of the affected hemispheres. There was significant correlation between flow data within tumors and angiographic tumor stains in meningiomas. Influence of tumors on cerebral blood flow of the normal tissue was greater in meningiomas than in gliomas. There was negative correlation between the degree of peripheral edema and the flow data of the affected hemisphere. It has been concluded that the measurement of CBF in brain tumors is a valuable method in evaluation of brain tumors. (author)

  2. Regional cerebral blood flow measurement in brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Izunaga, Hiroshi; Hirota, Yoshihisa; Takahashi, Mutsumasa; Fuwa, Isao; Kodama, Takafumi; Matsukado, Yasuhiko

    1986-10-01

    The regional cerebral blood flow (CBF) was determined on seventeen patients with brain tumors. Ring type single photon emission CT (SPECT) was used following intravenous injection of /sup 133/Xe. Case materials included eleven meningiomas and six malignant gliomas. Evaluation was performed with emphasis on the following points; 1. Correlation of the flow data within tumors to the angiographic tumor stains, 2. Influence of tumors on the cerebral blood flow of the normal brain tissue, 3. Correlation between degree of peripheral edema and the flow data of the affected hemispheres. There was significant correlation between flow data within tumors and angiographic tumor stains in meningiomas. Influence of tumors on cerebral blood flow of the normal tissue was greater in meningiomas than in gliomas. There was negative correlation between the degree of peripheral edema and the flow data of the affected hemisphere. It has been concluded that the measurement of CBF in brain tumors is a valuable method in evaluation of brain tumors.

  3. EXPERIMENTAL MEASUREMENT, ANALYSIS AND MODELLING ...

    African Journals Online (AJOL)

    30 juin 2010 ... We obtain a good agreement between the resolution of the nonlinear equation of heat and the results obtained by the experimentation. . Keywords: Emissivity, Température, optimal Linearisation, finite elements. 1. ..... basse température, Rapport de Stage de D.E.A, Université Paris 12 – Val de Marne.

  4. Treatment of Experimental Brain Tumors with Trombospondin-1 Derived Peptides: an In Vivo Imaging Study

    Directory of Open Access Journals (Sweden)

    A. Bogdanov, Jr.

    1999-11-01

    Full Text Available Antiangiogenic and antiproliferative effects of synthetic D-reverse peptides derived from the type 1 repeats of thrombospondin (TSP1 [1,2] were studied in rodent C6 glioma and 9L gliosarcomas. To directly measure tumor size and vascular parameters, we employed in vivo magnetic resonance (MR imaging and corroborated results by traditional morphometric tissue analysis. Rats bearing either C6 or 9L tumors were treated with TSP1-derived peptide (D-reverse amKRFKQDGGWSHWSPWSSac, n=13 or a control peptide (D-reverse am KRAKQAGGASHASPASSac, n=12 at 10 mg/kg, administered either intravenously or through subcutaneous miniosmotic pumps starting 10 days after tumor implantation. Eleven days later, the effect of peptide treatment was evaluated. TSP1 peptide-treated 9L tumors (50.7±44.2 mm3, n=7 and C6 tumors (41.3±34.2 mm3, n=6 were significantly smaller than tumors treated with control peptide (9L: 215.7±67.8 mm3, n=6; C6:184.2±105.2 mm3, n=6. In contrast, the in vivo vascular volume fraction, the mean vascular area (determined by microscopy, and the microvascular density of tumors were not significantly different in any of the experimental groups. In cell culture, TSP1, and the amKRFKQDGGWSHWSPWSSac peptide showed antiproliferative effects against C6 with an IC of 45 nM for TSP1. These results indicate that TSP1derived peptides retard brain tumor growth presumably as a result of slower de novo blood vessel formation and synergistic direct antiproliferative effects on tumor cells. We also show that in vivo MR imaging can be used to assess treatment efficacy of novel antiangiogenic drugs non-invasively, which has obvious implications for clinical trials.

  5. MRI monitoring of tumor response following angiogenesis inhibition in an experimental human breast cancer model

    International Nuclear Information System (INIS)

    Turetschek, Karl; Preda, Anda; Shames, David M.; Novikov, Viktor; Roberts, Timothy P.L.; Fu, Yanjun; Brasch, Robert C.; Floyd, Eugenia; Carter, Wayne O.; Wood, Jeanette M.

    2003-01-01

    The aim of this study was to evaluate the potential of dynamic magnetic resonance imaging (MRI) enhanced by macromolecular contrast agents to monitor noninvasively the therapeutic effect of an anti-angiogenesis VEGF receptor kinase inhibitor in an experimental cancer model. MDA-MB-435, a poorly differentiated human breast cancer cell line, was implanted into the mammary fat pad in 20 female homozygous athymic rats. Animals were assigned randomly to a control (n=10) or drug treatment group (n=10). Baseline dynamic MRI was performed on sequential days using albumin-(GdDTPA) 30 (6.0 nm diameter) and ultrasmall superparamagnetic iron oxide (USPIO) particles (30 nm diameter). Subjects were treated either with PTK787/ZK 222584, a VEGF receptor tyrosine kinase inhibitor, or saline given orally twice daily for 1 week followed by repeat MRI examinations serially using each contrast agent. Employing a unidirectional kinetic model comprising the plasma and interstitial water compartments, tumor microvessel characteristics including fractional plasma volume and transendothelial permeability (K PS ) were estimated for each contrast medium. Tumor growth and the microvascular density, a histologic surrogate of angiogenesis, were also measured. Control tumors significantly increased (P PS ) based on MRI assays using both macromolecular contrast media. In contrast, tumor growth was significantly reduced (P PS values declined slightly. Estimated values for the fractional plasma volume did not differ significantly between treatment groups or contrast agents. Microvascular density counts correlated fairly with the tumor growth rate (r=0.64) and were statistically significant higher (P PS ), using either of two macromolecular contrast media, were able to detect effects of treatment with a VEGF receptor tyrosine kinase inhibitor on tumor vascular permeability. In a clinical setting such quantitative MRI measurements could be used to monitor tumor anti-angiogenesis therapy. (orig.)

  6. Circulating Tumor Cells Measurements in Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Franck Chiappini

    2012-01-01

    Full Text Available Liver cancer is the fifth most common cancer in men and the seventh in women. During the past 20 years, the incidence of HCC has tripled while the 5-year survival rate has remained below 12%. The presence of circulating tumor cells (CTC reflects the aggressiveness nature of a tumor. Many attempts have been made to develop assays that reliably detect and enumerate the CTC during the development of the HCC. In this case, the challenges are (1 there are few markers specific to the HCC (tumor cells versus nontumor cells and (2 they can be used to quantify the number of CTC in the bloodstream. Another technical challenge consists of finding few CTC mixed with million leukocytes and billion erythrocytes. CTC detection and identification can be used to estimate prognosis and may serve as an early marker to assess antitumor activity of treatment. CTC can also be used to predict progression-free survival and overall survival. CTC are an interesting source of biological information in order to understand dissemination, drug resistance, and treatment-induced cell death. Our aim is to review and analyze the different new methods existing to detect, enumerate, and characterize the CTC in the peripheral circulation of patients with HCC.

  7. Measurement of some tumor markers by IRMA in vietnam

    International Nuclear Information System (INIS)

    Tran Xuan Truong

    2004-01-01

    As we known that a perfect tumor markers could be used in five different ways : for population screening, for diagnose, for monitoring therapy and for follow-up early evidence of cancer recurrence. In order to achieve perfect status a tumor markers would require total negativity in healthy subject, total positivity for single tumor type and close correlation between plasma tumor marker concentration and tumor size . The advance of monoclonal antibodies has had dramatic impact in oncology, where new tumor markers have been discovered and assay methods for all tumor markers have been improved commercially . Analytical performance of these new methods are potentially as good as that of the best Immunoradiometric assay for others analytes. In Vietnam, the first time we use immunoradiometric assay (IRMA) for the measurement of some tumor markers in normal subject and cancer diseases. These are Thyroglobulin (TG) of thyroid cancer, cancer-antigen 15-3 (CA15-3) of breast cancer and cancer-antigen 72-4 (CA72-4) of stomach cancer. We would like applying the CA72-4 in the indication of stomach cancer, CA15-3 in the differential diagnosis of breast cancer, and TG in the differential diagnosis of thyroid cancer. And all of these tumor markers were also used in the clinical follow-up and early detection of recurrence and metastatic Cancer of them. We could try researching on them much more. (authors)

  8. Oxygenation level and hemoglobin concentration in experimental tumor estimated by diffuse optical spectroscopy

    Science.gov (United States)

    Orlova, A. G.; Kirillin, M. Yu.; Volovetsky, A. B.; Shilyagina, N. Yu.; Sergeeva, E. A.; Golubiatnikov, G. Yu.; Turchin, I. V.

    2017-07-01

    Using diffuse optical spectroscopy the level of oxygenation and hemoglobin concentration in experimental tumor in comparison with normal muscle tissue of mice have been studied. Subcutaneously growing SKBR-3 was used as a tumor model. Continuous wave fiber probe diffuse optical spectroscopy system was employed. Optical properties extraction approach was based on diffusion approximation. Decreased blood oxygen saturation level and increased total hemoglobin content were demonstrated in the neoplasm. The main reason of such differences between tumor and norm was significant elevation of deoxyhemoglobin concentration in SKBR-3. The method can be useful for diagnosis of tumors as well as for study of blood flow parameters of tumor models with different angiogenic properties.

  9. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  10. Experimental study of anti-tumor activity of direct current

    International Nuclear Information System (INIS)

    Ito, Hisao; Hashimoto, Shozo

    1989-01-01

    The anti-tumor activity of direct current combined with radiation was studied. The experiments were performed with fibrosarcomas (FSA, NFSA) syngenetic to C3H mice. Direct current (0.6mA, 120min) alone was effective to reduce the tumor sizes, but could not cure the tumors. When the direct current therapy (DC therapy) was combined with radiation the DC therapy following radiation was more effective than that before radiation. Using TCD 50 assay, the DC therapy enhanced the effect of a single dose of radiation with the dose-modifying factor of 1.2. However, tumor control rates by the combination therapy were more improved at the smaller doses of radiation than at the larger ones. When the single DC therapy (0.6mA, 120min) was applied immediately after the first radiation of fractionated one the combination therapy still showed the enhanced effect. However, both DC therapy and the radiation therapy were divided in three fractions, and the DC therapy (0.6mA, 40min) was applied after each radiation. Tumor growth retardation by the combination therapy was no different from that by radiation alone. This result suggests that there might be a minimum required dose of coulombs to show the effect of the combination therapy. (author)

  11. Experimental studies on the effect of perfluorochemicals in tumor irradiation

    International Nuclear Information System (INIS)

    Shinoda, Jun; Iwai, Tomohiko; Hattori, Tatsuaki; Kondo, Hiroaki; Sakai, Noboru; Yamada, Hiroshi

    1984-01-01

    The effects of radiation therapy with Fluosol-DA on rat mammary tumors were studied. The tissue oxygen tension values of tumors in breathing mixed gas (5% carbon dioxide and 95% oxygen) with Fluosol-DA (25 ml/kg, i.v.) were significantly higher than those in room air without Fluosol-DA. The rats were divided into three groups: Group I received Fluosol-DA but no irradiation, Group II was treated with 1000 rads of irradiation using 60 Co without Fluosol-DA in room air and Group III received the same irradiation and Fluosol-DA in breathig mixed gas. In the latter group we observed a prolongation of the survival time and suppression of the tumor growth. (author)

  12. Experimental Measurement-Device-Independent Entanglement Detection

    Science.gov (United States)

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-02-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols.

  13. Tumors in dogs exposed to experimental intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Johnstone, Peter A.S.; Laskin, William B.; De Luca, Anne Marie; Barnes, Margaret; Kinsella, Timothy J.; Sindelar, William F.

    1996-01-01

    Purpose: The frequency of radiation-induced neoplasms was determined in dogs enrolled in the National Cancer Institute canine trials of intraoperative radiotherapy (IORT). Methods and Materials: Twelve protocols assessing normal tissue response to IORT involved 238 dogs in a 15-year trial. Eighty-one dogs were followed for > 24 months postoperatively and were assessed for tumor development; 59 of these animals received IORT. Results: Twelve tumors occurred in the 59 dogs receiving IORT. Nine were in the IORT portals and were considered to be radiation induced. No tumors occurred in 13 sham animals or in 9 animals treated with external beam radiotherapy alone. The frequency of radiation-induced malignancies in dogs receiving IORT was 15%, and was 25% in animals receiving ≥ 25 Gy IORT. Frequency of all tumors, including spontaneous lesions, was 20%. Conclusions: Intraoperative radiotherapy contributed to a high frequency of sarcoma induction in these dogs. Unknown to date in humans involved in clinical trials of IORT, this potential complication should be looked for as long-term survivors are followed

  14. Molecular analysis of radiation-induced experimental tumors in mice

    International Nuclear Information System (INIS)

    Niwa, O.; Muto, M.; Suzuki, F.

    1992-01-01

    Molecular analysis was made on mouse tumors induced by radiation and chemicals. Expression of oncogenes was studied in 12 types of 178 mouse tumors. Southern blotting was done on tumors in which overexpression of oncogenes was noted. Amplification of the myc oncogene was found in chemically induced sarcomas, but not those induced by radiations. Radiogenic thymomas were studied in detail. These thymomas were induced in two different ways. The first was thymomas induced by direct irradiation of F1 mice between C57BL/6NxC3H/He. Southern analysis of DNA revealed deletion of specific minisatellite bands in these tumors. DNA from directly induced thymomas induced focus formation when transfected into normal Golden hamster cells. The mouse K-ras oncogene was detected in these transformants. The second type of thymomas was induced by X-irradiation of thymectomized B10.thy1.2 mice in which normal thymus from congenic B10,thy1.1. mice was grafted. Thymomas of the donor origin was analysed by transfection and the transformants by DNA from those indirectly induced thymomas did not contain activated ras oncogenes. (author)

  15. Relations between radiobiological hypoxia and nuclear magnetic resonance-imaged blood microcirculation in experimental tumors

    International Nuclear Information System (INIS)

    Koike, Sachiko; Ando, Koichi; Ikehira, Hiroo.

    1993-01-01

    Characteristics of hypoxic cells subjected to radiation were investigated and compared with those of microcirculation for two murine fibrosarcomas growing in C3H mice. Small NFSa tumors, growing in air-breathing mice, developed a radioresistant tail on the survival curve. The tail was indistinguishably parallel to a survival curve for an artificially hypoxic tumor. As the NFSa tumors increased in size, the hypoxic tail moved upward with no change of Do, resulting in increase of hypoxic fraction from 3.9% to 40%. The R1137 tumors had no radioresistant tail nor hypoxic fraction regardless of tumor size. However, large-sized R1137 tumors developed a significant number of radioresistant, hypoxic cells with an intermediate Do, and were effectively sensitized by administrating misonidazole before irradiation. Thus, the NFSa tumors were fractionally hypoxic, and the large R1137 tumors had intermediate hypoxia. Measurement of tumor microcirculation by gadolinium-enhanced nuclear magnetic resonance indicated that both blood flow and blood volume decreased significantly when the NFSa tumor grew large. Similar reduction in these microcirculation parameters was also observed for the R1137 tumor. The small-sized NFSa tumor had relatively larger blood volume and faster blood flow than the small-sized R1137 tumor. When large-sized tumors were compared to each other, the NFSa again had better blood flow than the R1137. However, the blood volume in the large-sized tumors was significantly (p<0.05) smaller for the NFSa tumor than for the R1137 tumor. It was concluded that blood flow could not be a single determinant for tumor hypoxia, and the difference between fractional hypoxia and intermediate hypoxia would be reflected in the ratio of blood flow to blood volume. (author)

  16. Experimental measurements at the MASURCA facility

    International Nuclear Information System (INIS)

    Assal, W.; Bosq, J.C.; Mellier, F.

    2012-01-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, MASURCA (meaning 'mock-up facility for fast breeder reactor studies at Cadarache') is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems). For this purpose are implemented electronics modules to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electric and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at MASURCA will be presented. (authors)

  17. Experimental Measurements at the MASURCA Facility

    Science.gov (United States)

    Assal, W.; Bosq, J. C.; Mellier, F.

    2012-12-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, MASURCA (meaning “mock-up facility for fast breeder reactor studies at CADARACHE”) is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems ...). For this purpose are implemented electronics modules to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electric and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at MASURCA will be presented.

  18. Experimental measurements at the Masurca facility

    International Nuclear Information System (INIS)

    AssaI, W.; Bosq, J. C.; Mellier, F.

    2009-01-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, Masurca (meaning 'mock-up facility for fast breeder reactor studies at Cadarache') is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems...). For this purpose electronics modules are implemented to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electrical and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at Masurca will be presented. (authors)

  19. A comparison of scintigraphy with tumor-seeking radiopharmaceuticals to detect an experimental bone tumors in the rabbits

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Sone, Teruki; Fukunaga, Masao

    2003-01-01

    A comparative study on the accumulation of 99m Tc-phosphorous compound, 99m Tc-hexakis-2-methoxy isobutyl-isonitrile (MIBI), and 99m Tc-tetrofosmin (TF) in the experimental bone tumors using the VX-2 cell was performed. In the group of the femoral metastatic bone tumor, 99m Tc-MIBI showed no accumulation in the femur at 12 days after the transplantation despite the presence of a bone marrow tumor. In the group of the iliac metastatic bone tumor, a bone scintigraphy showed decreased accumulation in the ileum at 16 days, but hot lesions were observed in same sites at 18 days after the transplantation on 99m Tc-MIBI and 99m Tc-TF scintigrams. The tumor to soft tissue accumulation ratio was higher for 99m Tc-MIBI (3.03±1.03) than for 99m Tc-TF (2.55±0.80) (P 99m Tc-MIBI is less satisfactory for the early diagnosis of tumors than bone scintigraphy, and a combined study with both 99m Tc-phosphorous compounds and 99m Tc-MIBI is useful for the evaluation and diagnosis of lesions. (author)

  20. Polyradiomodification. Evaluation of the efficacy of the utilization of hyperglycemia in experimental hypoxiradiotherapy of tumors

    International Nuclear Information System (INIS)

    Kozin, S.V.; Dyuskaliev, Zh.D.; Yarmonenko, S.P.

    1984-01-01

    An experimental evaluation of the appropriateness of the use of short-term hyperglycemia combined with hypoxiradiotherapy of solid tumors is given. In comparing the response of tumors and overlying skin a conclusion has been made that gaseous hypoxia and the use of hyperglycemia separately yield in a considerable therapeutic benefit, and the use of the combination of these agents in some cases produces a greater therapeutic interval between tumor destruction and normal tissues. The mechanisms of the modification of radiation injuries of tumors and skin under the influence of the above two factors are discussed

  1. Radiosensitizing effect of nitric oxide in tumor cells and experimental tumors irradiated with gamma rays and proton beams

    International Nuclear Information System (INIS)

    Policastro, Lucia L.; Duran, Hebe; Molinari, Beatriz L.; Somacal, Hector R.; Valda, Alejandro A.

    2003-01-01

    Nitric oxide (NO) has been reported to be a radiosensitizer of mammalian cells under hypoxic conditions. In a previous study, we demonstrated an enhancement in radiation response induced by NO in mouse tumor cells under aerobic conditions, with an increasing effect as a function of malignancy. The aim of the present study was to evaluate the effect of NO in tumor cells and in experimental tumors irradiated with γ rays and proton beams. Irradiations were performed with a 137 Cs γ source and with proton beams generated by the TANDAR accelerator. Tumor cells were treated with the NO donor DETA-NO and the sensitizer enhancement ratio (SER) was calculated using the α parameter of the survival curve fitted to the linear-quadratic model. Tumor cells irradiated with protons were radio sensitized by DETA-NO only in the more malignant cells irradiated with low LET protons (2.69±0.08 keV/μm). For higher LET protons there were no radiosensitizing effect. For human tumor cells pre-treated with DETA-NO and irradiated with γ rays, a significantly greater effect was demonstrated in the malignant cells (MCF-7) as compared with the near normal cells (HBL-100). Moreover, a significant decrease in tumor growth was demonstrated in mice pre-treated with the NO donor spermine and irradiated with γ rays and low LET protons as compared with mice irradiated without pre-treatment with the NO donor. In conclusion, we demonstrated a differential effect of NO as a radiosensitizer of malignant cells, both with γ rays and low LET protons. This selectivity, coupled to the in vivo inhibition of tumor growth, is of great interest for the potential use of NO releasing agents in radiotherapy. (author)

  2. EXPERIMENTAL MEASUREMENT OF NANOFLUIDS THERMAL PROPERTIES

    Directory of Open Access Journals (Sweden)

    Adnan M. Hussein

    2013-07-01

    Full Text Available Solid particles dispersed in a liquid with sizes no larger than 100nm, known as nanofluids, are used to enhance Thermophysical properties compared to the base fluid. Preparations of alumina (Al2O3, titania (TiO2 and silica (SiO2 in water have been experimentally conducted in volume concentrations ranging between 1 and 2.5%. Thermal conductivity is measured by the hot wire method and viscosity with viscometer equipment. The results of thermal conductivity and viscosity showed an enhancement (0.5–20% and 0.5–60% respectively compared with the base fluid. The data measured agreed with experimental data of other researchers with deviation of less than 5%. The study showed that alumina has the highest thermal conductivity, followed silica and titania, on the other hand silica has the highest viscosity followed alumina and titania.

  3. Microvessel organization and structure in experimental brain tumors: microvessel populations with distinctive structural and functional properties.

    Science.gov (United States)

    Schlageter, K E; Molnar, P; Lapin, G D; Groothuis, D R

    1999-11-01

    We studied microvessel organization in five brain tumor models (ENU, MSV, RG-2, S635cl15, and D-54MG) and normal brain, including microvessel diameter (LMVD), intermicrovessel distance (IMVD), microvessel density (MVD), surface area (S(v)), and orientation. LMVD and IMVD were larger and MVD was lower in tumors than normal brain. S(v) in tumors overlapped normal brain values and orientation was random in both tumors and brain. ENU and RG-2 tumors and brain were studied by electron microscopy. Tumor microvessel wall was thicker than that of brain. ENU and normal brain microvessels were continuous and nonfenestrated. RG-2 microvessels contained fenestrations and endothelial gaps; the latter had a maximum major axis of 3.0 microm. Based on anatomic measurements, the pore area of RG-2 tumors was estimated at 7.4 x 10(-6) cm(2) g(-1) from fenestrations and 3.5 x 10(-5) cm(2) g(-1) from endothelial gaps. Increased permeability of RG-2 microvessels to macromolecules is most likely attributable to endothelial gaps. Three microvessel populations may occur in brain tumors: (1) continuous nonfenestrated, (2) continuous fenestrated, and (3) discontinuous (with or without fenestrations). The first group may be unique to brain tumors; the latter two are similar to microvessels found in systemic tumors. Since structure-function properties of brain tumor microvessels will affect drug delivery, studies of microvessel function should be incorporated into clinical trials of brain tumor therapy, especially those using macromolecules. Copyright 1999 Academic Press.

  4. Experimental measurement of energy harvesting with backpack

    Science.gov (United States)

    Pavelkova, Radka; Vala, David; Suranek, Pavel; Mahdal, Miroslav

    2017-08-01

    This article deals with the energy harvesting systems, especially the energy harvesting backpack, which appears as a convenient means for energy harvesting for mobile sensors power. Before starting the experiment, it was necessary to verify whether this energy will be sufficient to get acquainted with the human kinematics and analyze problematics itself. For this purpose there was used motion capture technology from Xsens. Measured data on the position of a particle moving man and back when walking, these data were then used for experimental realization of energy harvesting backpack and as input data to the simulation in Simulink, which brought us a comparison between theoretical assumptions and practical implementation. When measuring characteristics of energy harvesting system we have a problem with measurements on backpack solved when redoing of the hydraulic cylinder as a source of a suitable movement corresponding to the amplitude and frequency of human walk.

  5. Effect of fractionated radiotherapy using a hypoxic cell radiosensitizer, RK-28, on experimental murine tumor

    International Nuclear Information System (INIS)

    Tanaka, Shukaku

    1990-01-01

    The effect of a hypoxic cell radiosensitizer RK-28, on fractionated radiotherapy was studied using mice with implanted tumors. Experimental animal tumors were third generation isoplants of a mammary carcinoma which arose spontaneously in a C 3 H/He mouse. RK-28 was given to the mice at two dosages: 0.4 mg/g,b.wt. and 0.2 mg/g.b.wt. Total dose of irradiation was 20 Gy which was divided into the first 10 Gy irradiation and the second 10 Gy performed after a proper time interval such as 1, 24, 48 and 72 hours after the first 10 Gy irradiation. Tumor growth was evaluated by TGT 50 /3 times, which was defined as the time required for 50% of the tumors to regrow to the 3 times value of its initial volume. Tumor volume was measured every day and TGT 50 /3 times was calculated by logit analysis method. No significant differences were found in the TGT 50 /3 times among the groups treated by radiation alone, those treated by RK-administration alone and those without any treatment. TGT 50 value of control group without any treatment was 3.40 (days). TGT 50 value of another group treated by RK-28 alone was 3.46. and TGT 50 value of 20 Gy X-ray irradiation alone was 10.23. Under the fractionated X-ray irradiation alone, TGT 50 values of the various time interval such as 9, 14, 48 and 72 hours were 11.26, 10.42, 12.14 and 1.10. Under the combined treatment of the fractionated X-ray irradiation and RK-28 administration, TGT 50 values were 17.84, 16.42, 16.59 and 17.49. These TGT 50 /3 times values showed that RK-28 had a radiosensitizing effect when given with fractionated radiotherapy even at lower doses of RK-28 administration and radiation. Therefore, it was suggested that fractionated radiotherapy using RK-28 was useful in the cancer treatment. (author) 52 refs

  6. Experimental research of digital holographic microscopic measuring

    Science.gov (United States)

    Zhu, Xueliang; Chen, Feifei; Li, Jicheng

    2013-06-01

    Digital holography is a new imaging technique, which is developed on the base of optical holography, Digital processing, and Computer techniques. It is using CCD instead of the conventional silver to record hologram, and then reproducing the 3D contour of the object by the way of computer simulation. Compared with the traditional optical holographic, the whole process is of simple measuring, lower production cost, faster the imaging speed, and with the advantages of non-contact real-time measurement. At present, it can be used in the fields of the morphology detection of tiny objects, micro deformation analysis, and biological cells shape measurement. It is one of the research hot spot at home and abroad. This paper introduced the basic principles and relevant theories about the optical holography and Digital holography, and researched the basic questions which influence the reproduce images in the process of recording and reconstructing of the digital holographic microcopy. In order to get a clear digital hologram, by analyzing the optical system structure, we discussed the recording distance and of the hologram. On the base of the theoretical studies, we established a measurement and analyzed the experimental conditions, then adjusted them to the system. To achieve a precise measurement of tiny object in three-dimension, we measured MEMS micro device for example, and obtained the reproduction three-dimensional contour, realized the three dimensional profile measurement of tiny object. According to the experiment results consider: analysis the reference factors between the zero-order term and a pair of twin-images by the choice of the object light and the reference light and the distance of the recording and reconstructing and the characteristics of reconstruction light on the measurement, the measurement errors were analyzed. The research result shows that the device owns certain reliability.

  7. Experimental measurement of proton penetration in silicon

    International Nuclear Information System (INIS)

    Castaing, C.; Baruch, P.; Picard, C.

    1974-01-01

    After proton implantation in silicon at high fluence, hydrogen precipitation in bubbles is induced by annealing. The stresses are so high that blister formation and peeling occur, leaving flat bottomed pits, with a depth equal to the projected proton range R(p). In this way R(p) was measured between 200 and 600keV, and compared with already published values, and with values computed through LSS (Lindhard, Scharff, and Schiott) theory, using a correct electronic stopping power. A table of ranges and standard deviations, computed in this way is given. The agreement with experimental results is excellent [fr

  8. Effects of experimental radiotherapy and hyperthermia on tumors and normal tissues in small animals

    International Nuclear Information System (INIS)

    Wondergem, J.

    1985-01-01

    Experiments on responses of tumors, implanted subcutaneously in the leg, to irradiation alone or combined with heat are reported. The influence of factors modifying the fraction of hypoxic cells (e.g. anesthesia of the animal and tumor volume) is also discussed. The radiosensitivity of developing lung tumors was examined for spontaneous as well as for artificial lung metastases. Both experimental tumor models were compared with regard to their value in experimental radiotherapy. Data obtained on the response of artificial metastases and lung tissue to combined treatment with irradiation and several drugs are presented. Data on damage of the mouse foot, as a result of heat and/or irradiation treatments are presented. In particular the influence of thermotolerance on thermal enhancement of the radiation induced skin reaction was studied. Tolerance of the skin of previously irradiated mice to retreatment with irradiation, to hyperthermia alone and combined with X-rays was assessed. (Auth.)

  9. Hyperbaric pressure effects measured by growth of a transplantable tumor in the C3H/HeN mouse.

    Science.gov (United States)

    Herndon, B L; Lally, J J

    1984-09-01

    Both hypobaric exposure at 0.5 atmospheres absolute (ATA) and hyperbaric pressure exposure at 3.5-8 ATA slowed transplantable tumor growth. These experiments detailed the hyperbaric pressure exposure. C3H/HeN-MTV+ mice, bearing the 16/C transplantable murine mammary adenocarcinoma and exposed to 18 days' treatment by a hyperbaric chamber at 3.5-8 ATA, had tumor weights that averaged 50-75% less than the tumor weights in mice caged at ambient ("sea level") pressure. A series of experiments was run to investigate this response to hyperbaric pressure exposure. After mice underwent continuous exposure to 3.5-8 ATA normoxic (normal oxygen) hyperbaric pressure with use of either argon or nitrogen inert gas, which began 3 days after tumor inoculation, tumors were removed at about 3 weeks' growth from these pressure-exposed mice and measured for growth by weighing. Final tumor weight in pressure-exposed experimental mice was significantly less than tumor weight in paired groups of tumor-bearing controls that received no hyperbaric pressure. Tumor weight was inversely related to pressure "dose," although the small pressure range produced an effect at all pressures used. The number of compression-decompression cycles to which the animals were subjected, however, was related positively to tumor weight at necropsy. Continued tumor growth in mice subjected to frequent pressure change (in conjunction with pressure exposure that otherwise limited tumor size) was unexplained by these experiments. The greatest difference between tumor weights in controls and pressure-exposed animals was seen with 2 weeks' continuous pressure exposure. A limited profile of blood tests was performed, and these reflected only minor, expected change in the pressure-exposed experimental animals. The data at hand did not suggest a mechanism by which chronic normoxic hyperbaric pressure limited tumor size.

  10. Hyperglycemia and ultrasound in radiotherapy of experimental tumors (a preliminary paper)

    International Nuclear Information System (INIS)

    Muratkhodzhaev, N.K.; Prus, E.S.; Zakirkhodzhaev, U.D.; Kutlimuratov, A.B.

    1984-01-01

    Experimental studies have shown that all the types of effects, as compared with the control, result in inhibition of the tumor growth; X-ray therapy decelerates the tumor growth, but its combination with hyperglycemia produced a more vivid effect. Inhibition of the tumor growth, as compared with that in the control group, was observed under a combined effect of hyperglycemia with ultrasound, though it was noticeably weaker than under other effects. Application of a complex effect including hyperglycemia, ultrasound, X-ray therapy turned to be most effective, the succession of their application playing an important role for the antitumoral effect of the used factors

  11. Effects of a Tumor Necrosis Factor-α Antagonist on Experimentally Induced Rhinosinusitis

    Directory of Open Access Journals (Sweden)

    Dong-Hyun Kim

    2011-01-01

    Full Text Available This prospective, randomized, and controlled study examined the effects of tumor necrosis factor soluble receptor type I (sTNFRI, a TNF-α antagonist on experimentally induced rhinosinusitis in rats. The experimental groups received an instillation of lipopolysaccharide (LPS plus an intramuscular injection of amoxicillin/clavulanate (antibiotic group, an instillation of sTNFRI (sTNFRI group, an instillation of sTNFRI and an injection of amoxicillin/clavulanate (sTNFRI/antibiotic group, or no additional treatment (LPS group. Histopathological changes were determined using hematoxylin-eosin and periodic acid-Schiff (PAS staining. Leakage of exudate was determined using fluorescence microscopy. Vascular permeability was measured using the Evans blue dye technique. Expression of MUC5AC was measured using reverse transcriptase PCR. The sTNFRI, antibiotic, and sTNFRI/antibiotic groups had significantly less capillary permeability, mucosal edema, PAS staining, and expression of MUC5AC than the LPS group. There were no differences in capillary permeability, mucosal edema, PAS staining, and MUC5AC expression between the sTNFRI and sTNFRI/antibiotic groups. The antibiotic group had PAS staining similar to that of the sTNFRI and sTNFRI/antibiotic groups but had a greater increase in capillary permeability, mucosal edema, and MUC5AC expression. This study shows that sTNFRI reduces inflammatory activity and mucus hypersecretion in LPS-induced rhinosinusitis in rats.

  12. Effect of aged garlic extract on immune responses to experimental fibrosarcoma tumor in BALB/c mice.

    Science.gov (United States)

    Tabari, M Abouhosseini; Ebrahimpour, S

    2014-01-01

    Aged garlic extract (AGE) has many biological activities including radical scavenging, antioxidative and immunomodulative effects. In this research work, the antitumor and immunomodulatory effects of AGE against fibrosarcoma implanted tumor were studied. WEHI-164 fibrosarcoma cells were implanted subcutaneously on day 0 into the right flank of 40 BALB/c mice at age of 8 weeks. Mice were randomly categorized in two separate groups: First received AGE (100 mg/kg, IP), second group as the control group received phosphate buffered saline. Treatments were carried out 3 times/week. Tumor growth was measured and morbidity was recorded. Subpopulations of CD4+/CD8+ T cells were determined using flow cytometry. WEHI-164 cell specific cytotoxicity of splenocytes and in vitro production of interferon gamma (IFN-γ) and interleukin-4 cytokines were measured. The mice received AGE had significantly longer survival time compared with the control mice. The inhibitory effect on tumor growth was seen in AGE treated mice. The CD4+/CD8+ ratio and in vitro IFN-γ production of splenocytes were significantly increased in AGE group. WEHI-164 specific cytotoxicity of splenocytes from AGE mice was also significantly increased at 25:1 E: T ratio. Administration of AGE resulted in improved immune responses against experimentally implanted fibrosarcoma tumors in BALB/c mice. AGE showed significant effects on inhibition of tumor growth and longevity of survival times.

  13. How to measure breast cancer tumoral size at MR imaging?

    International Nuclear Information System (INIS)

    Thomassin-Naggara, I.; Siles, Pascale; Trop, I.; Chopier, J.; Darai, E.; Bazot, M.

    2013-01-01

    Objective: To compare the accuracy of different MR sequences to measure tumor size. Methods: Eighty-six women (mean age: 53 years (30–78)) who underwent preoperative MRI for breast cancer were included. Maximal diameters of the index tumor (IT) and of the whole extent of the tumor (WET) were measured on T2-weighted (T2W) sequences, on dynamic contrast-enhanced (DCE) T1-weighted (T1W) sequences and on Maximal Intensity Projection (MIP) reconstructions. Agreements with pathological size were evaluated using concordance correlation coefficient (k). Results: Median pathological size of IT was 20 mm (13–25 mm, interquartile range). Median pathological size of the WET was 29 mm (16–50 mm, interquartile range). Measurement of IT showed a good concordance with pathological size, with best results using T2W (k = 0.690) compared to MIP (k = 0.667), early-subtracted DCE frame (k = 0.630) and early-native DCE frame (k = 0.588). IT was visible on T2W in 83.7% and accurately measured within 5 mm in 69.9%. Measurement of WET was superior using early-subtracted DCE frame (k = 0.642) compared to late-native frame (k = 0.635), early-native frame (k = 0.631), late-subtracted frame (k = 0.620) and MIP (k = 0.565). However, even using early-subtracted frame, WET was accurately measured within 5 mm only 39.3%. Conclusion: If visible, IT size is best measured on T2W with a good accuracy (69%) whereas WET is best estimated on early-subtracted DCE frame. However, when adjacent additional sites exist around IT, suspected surrounding disease components need to be proved by pathological analysis

  14. In vivo measurement of tumor estradiol and Vascular Endothelial Growth Factor in breast cancer patients

    International Nuclear Information System (INIS)

    Garvin, Stina; Dabrosin, Charlotta

    2008-01-01

    Angiogenesis, crucial for tumor progression, is a process regulated in the tissue micro-environment. Vascular endothelial growth factor (VEGF) is a potent stimulatory factor of angiogenesis and a negative prognostic indicator of breast cancer. VEGF is biologically active in the extracellular space and hitherto, there has been a lack of techniques enabling sampling of angiogenic molecules such as VEGF in situ. The majority of breast cancers are estrogen-dependent, and estrogen has been shown to regulate VEGF in normal breast tissue and experimental breast cancer. We investigated if microdialysis may be applicable in human breast cancer for sampling of extracellular VEGF in situ and to explore if there is an association with local estradiol and VEGF levels in normal and cancerous breast tissue. Microdialysis was used to sample VEGF and estradiol in tumors and adjacent normal breast tissue in postmenopausal breast cancer patients. VEGF and estradiol were also measured in plasma, and immunohistochemical staining for VEGF was performed on tumor sections. We show that in vivo levels of extracellular VEGF were significantly higher in breast cancer tumors than in normal adjacent breast tissue. There was a significant positive correlation between estradiol and extracellular VEGF in normal breast tissue. However, no correlation was detected between estradiol and VEGF in tumors or between tumor VEGF and plasma VEGF. We conclude that VEGF and estradiol correlates significantly in normal breast tissue. Microdialysis may be used to provide novel insight in breast tumor biology and the regulation of molecules in the extracellular space of human breast tumors in vivo

  15. Measurement of lung tumor motion using respiration-correlated CT

    International Nuclear Information System (INIS)

    Mageras, Gig S.; Pevsner, Alex; Yorke, Ellen D.; Rosenzweig, Kenneth E.; Ford, Eric C.; Hertanto, Agung; Larson, Steven M.; Lovelock, D. Michael; Erdi, Yusuf E.; Nehmeh, Sadek A.; Humm, John L.; Ling, C. Clifton

    2004-01-01

    Purpose: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. Methods and materials: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. Results: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3

  16. A system for tumor heterogeneity evaluation and diagnosis based on tumor markers measured routinely in the laboratory.

    Science.gov (United States)

    Hui, Liu; Rixv, Liu; Xiuying, Zhou

    2015-12-01

    To develop an efficient and reliable approach to estimate tumor heterogeneity and improve tumor diagnosis using multiple tumor markers measured routinely in the clinical laboratory. A total of 161 patients with different cancers were recruited as the cancer group, and 91 patients with non-oncological conditions were required as the non-oncological disease group. The control group comprised 90 randomly selected healthy subjects. AFP, CEA, CYFRA, CA125, CA153, CA199, CA724, and NSE levels were measured in all these subjects with a chemiluminescent microparticle immunoassay. The tumor marker with the maximum S/CO value (sample test value:cutoff value for discriminating individuals with and without tumors) was considered as a specific tumor marker (STM) for an individual. Tumor heterogeneity index (THI)=N/P (N: number of STMs; P: percentage of individuals with STMs in a certain tumor population) was used to quantify tumor heterogeneity: high THI indicated high tumor heterogeneity. The tumor marker index (TMI), TMI = STM×(number of positive tumor markers+1), was used for diagnosis. The THIs of lung, gastric, and liver cancers were 8.33, 9.63, and 5.2, respectively, while the ROC-areas under the curve for TMI were 0.862, 0.809, and 0.966. In this study, we developed a novel index for tumor heterogeneity based on the expression of various routinely evaluated serum tumor markers. Development of an evaluation system for tumor heterogeneity on the basis of this index could provide an effective diagnostic tool for some cancers. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Experimental Measurement of In Situ Stress

    Science.gov (United States)

    Tibbo, Maria; Milkereit, Bernd; Nasseri, Farzine; Schmitt, Douglas; Young, Paul

    2016-04-01

    The World Stress Map data is determined by stress indicators including earthquake focal mechanisms, in situ measurement in mining, oil and gas boreholes as well as the borehole cores, and geologic data. Unfortunately, these measurements are not only infrequent but sometimes infeasible, and do not provide nearly enough data points with high accuracy to correctly infer stress fields in deep mines around the world. Improvements in stress measurements of Earth's crust is fundamental to several industries such as oil and gas, mining, nuclear waste management, and enhanced geothermal systems. Quantifying the state of stress and the geophysical properties of different rock types is a major complication in geophysical monitoring of deep mines. Most stress measurement techniques involve either the boreholes or their cores, however these measurements usually only give stress along one axis, not the complete stress tensor. The goal of this project is to investigate a new method of acquiring a complete stress tensor of the in situ stress in the Earth's crust. This project is part of a comprehensive, exploration geophysical study in a deep, highly stressed mine located in Sudbury, Ontario, Canada, and focuses on two boreholes located in this mine. These boreholes are approximately 400 m long with NQ diameters and are located at depths of about 1300 - 1600 m and 1700 - 2000 m. Two borehole logging surveys were performed on both boreholes, October 2013 and July 2015, in order to perform a time-lapse analysis of the geophysical changes in the mine. These multi-parameter surveys include caliper, full waveform sonic, televiewer, chargeability (IP), and resistivity. Laboratory experiments have been performed on borehole core samples of varying geologies from each borehole. These experiments have measured the geophysical properties including elastic modulus, bulk modulus, P- and S-wave velocities, and density. The apparatus' used for this project are geophysical imaging cells capable

  18. Changes in tumor oxygenation during a combined treatment with fractionated irradiation and hyperthermia: an experimental study.

    Science.gov (United States)

    Zywietz, F; Reeker, W; Kochs, E

    1997-01-01

    To determine the influence of adjuvant hyperthermia on the oxygenation status of fractionated irradiated tumors. Oxygen partial pressure (pO2) in rat rhabdomyosarcomas (R1H) was measured sequentially at weekly intervals during a fractionated irradiation with 60Co-gamma-rays (60 Gy/20f/4 weeks) in combination with local hyperthermia (8 f(HT) at 43 degrees C, 1 h/4 weeks). Tumors were heated twice weekly with a 2450 MHz microwave device at 43 degrees C, 1 h starting 10 min after irradiation. The pO2 measurements (pO2-histograph, Eppendorf, Germany) were performed in anesthetized animals during mechanical ventilation and in hemodynamic steady state. All tumor pO2 measurements were correlated to measurements of the arterial oxygen partial pressure (paO2) determined by a blood gas analyzer. The oxygenation status of R1H tumors decreased continuously from the start of the combined treatment, with increasing radiation dose and number of heat fractions. In untreated controls a median tumor pO2 of 23 +/- 2 mmHg (mean +/- SEM) was measured. Tumor pO2 decreased to 11 +/- 2 mmHg after 30 Gy + 4 HT (2 weeks), and to 6 +/- 2 mmHg after 60 Gy + 8HT (4 weeks). The increase in the frequency of pO2-values below 5 mmHg and the decrease in the range of the pO2 histograms [delta p(10/90)] further indicated that tumor hypoxia increased relatively rapidly from the start of combined treatment. After 60 Gy + 8HT 48 +/- 5% (mean +/- SEM) of the pO2-values recorded were below 5 mmHg. These findings suggest that adjuvant hyperthermia to radiotherapy induces greater changes in tumor oxygenation than radiation alone [cf. (39)]. This might be of importance for the temporary application of hyperthermia in the course of a conventional radiation treatment.

  19. Experimental Pressure Measurements on Hydropower Turbine Runners

    Energy Technology Data Exchange (ETDEWEB)

    Harding, Samuel F.; Richmond, Marshall C.

    2017-04-28

    The range of hydrodynamic operating conditions to which the turbine is exposed results in significant pressure fluctuations on both the pressure and suction sides of the blades. Understanding these dynamic pressures has a range of applications. Structurally, the resulting dynamic loads are significant in understanding the design life and maintenance schedule of the bearing, shafts and runner components. The pulsing pressures have also been seen to have a detrimental effect on the surface condition of the blades. Biologically, the pressure gradients and pressure extremes are the primary driver of barotrauma for fish passing through hydroturbines. Improvements in computational fluid dynamics (CFD) can be used to simulate such unsteady pressures in the regions of concern. High frequency model scale and prototype measurements of pressures at the blade are important in the validation of these models. Experimental characterization of pressure fields over hydroturbine blades has been demonstrated by a number of studies which using multiple pressure transducers to map the pressure contours on the runner blades. These have been performed at both model and prototype scales, often to validate computational models of the pressure and flow fields over the blades. This report provides a review of existing studies in which the blade pressure was measured in situ. The report assesses the technology for both model and prototype scale testing. The details of the primary studies in this field are reported and used to inform the types of hardware required for similar experiments based on the Ice Harbor Dam owned by the US Corps of Engineers on the Snake River, WA, USA. Such a study would be used to validate the CFD performed for the BioPA.

  20. In vivo BNCT in experimental and spontaneous tumors at RA-1 reactor

    International Nuclear Information System (INIS)

    Trivillin, Veronica A.; Heber, Elisa M.; Itoiz, Maria E.; Schwint, Amanda E.; Nigg, David W.

    2003-01-01

    Within the search for new applications of Boron Neutron Capture Therapy (BNCT) and the basic research oriented towards the study of BNCT radiobiology to optimize its therapeutic gain, we previously proposed and validated the hamster cheek pouch oral cancer model and showed, for the first time, the success of BNCT to treat oral cancer in an experimental model. The staff of the Ra-1 Reactor (Constituyentes Atomic Center) adapted the thermal beam and physical set-up to perform in vivo BNCT of superficial tumors in small animals. We preformed a preliminary characterization of the thermal beam, performed beam only irradiation of normal and tumor bearing hamsters and in vivo BNCT of experimental oral squamous cell carcinomas in hamsters mediated by boron phenylalanine (BPA) and GB-10 (Na 2 10 B 10 H 10 ). Having demonstrated the absence of radio toxic effects in healthy tissue and a therapeutic effect of in vivo BNCT in hamster cheek pouch tumors employing the Ra-1 thermal beam, we performed a feasibility study of the treatment by BNCT of 3 terminal cases of spontaneous head and neck squamous cell carcinoma in cats following the corresponding biodistribution studies. This was the first treatment of spontaneous tumors by BNCT in our country and the first treatment by BNCT in cats worldwide. This preclinical study in terminal cases showed significant tumor control by BNCT with no damage to normal tissue. (author)

  1. Glioma Surgical Aspirate: A Viable Source of Tumor Tissue for Experimental Research

    International Nuclear Information System (INIS)

    Day, Bryan W.; Stringer, Brett W.; Wilson, John; Jeffree, Rosalind L.; Jamieson, Paul R.

    2013-01-01

    Brain cancer research has been hampered by a paucity of viable clinical tissue of sufficient quality and quantity for experimental research. This has driven researchers to rely heavily on long term cultured cells which no longer represent the cancers from which they were derived. Resection of brain tumors, particularly at the interface between normal and tumorigenic tissue, can be carried out using an ultrasonic surgical aspirator (CUSA) that deposits liquid (blood and irrigation fluid) and resected tissue into a sterile bottle for disposal. To determine the utility of CUSA-derived glioma tissue for experimental research, we collected 48 CUSA specimen bottles from glioma patients and analyzed both the solid tissue fragments and dissociated tumor cells suspended in the liquid waste fraction. We investigated if these fractions would be useful for analyzing tumor heterogeneity, using IHC and multi-parameter flow cytometry; we also assessed culture generation and orthotopic xenograft potential. Both cell sources proved to be an abundant, highly viable source of live tumor cells for cytometric analysis, animal studies and in-vitro studies. Our findings demonstrate that CUSA tissue represents an abundant viable source to conduct experimental research and to carry out diagnostic analyses by flow cytometry or other molecular diagnostic procedures

  2. Recent highlights of experimental research for inhibiting tumor growth by using Chinese medicine.

    Science.gov (United States)

    He, Xi-ran; Han, Shu-yan; Li, Ping-ping

    2015-10-01

    To give an overview of contemporary experimental research using Chinese medicine (CM) for the treatment of cancer. As an integral part of mainstream medicine in the People's Republic of China, CM emphasizes improvements in holistic physical condition instead of merely killing tumor cells, which is consistent with the current medical model that advocates patient-oriented treatment. Great progress has been made in experimental research, and the principle aspects include anti-tumor angiogenesis, inducing apoptosis and differentiation, reversing multidrug resistance, and improving immune function. As a current hot topic in cancer research, tumor microenvironment (TME) highlights the mutual and interdependent interaction between tumor cells and their surrounding tissues, and the CM treatment concept bears a striking resemblance to it. To date, primary points of TME include extracellular matrix remodeling, inflammation, hypoxia, and angiogenesis, but trials using CM with a focus on TME are rare. Despite considerable recent development, experimental research on CM for solving cancer issues appears insufficient. Greater efforts in this field are urgently needed.

  3. Determining tumor blood flow parameters from dynamic image measurements

    Science.gov (United States)

    Libertini, Jessica M.

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth[l]. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community[2], this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake[3]. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  4. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  5. Examination of tumor diameter measurement precision by RECIST

    International Nuclear Information System (INIS)

    Goto, Masami; Ino, Kenji; Akahane, Masaaki

    2007-01-01

    Image evaluation with Response Evaluation Criteria in Solid Tumors (RECIST) evaluates the change in a measurable lesion as determined by ruler or micrometer caliper. However, there is no definition of the conditions thought to influence the precision of measurement. We therefore examined the effects on measurement precision by changing image amplification, window width (WW), window level (WL), and time phase. Moreover, to determine response rate, one-dimensional evaluation with RECIST was compared with the two-dimensional evaluation of World Health Organization (WHO) for a hepatocellular carcinoma. The results of measuring the object lesion for measured value variation were as follows. Under image conditions of 1 time expansion/WW 150/WL 100 was (4.92±1.94)%. Under image conditions of 1 time expansion/WW 350/WL 75 was (4.42±1.70)%. Under image conditions of 4 times expansion/WW 150/WL 100 was (2.52±0.82)%. Under image conditions of 4 times expansion/WW 350/WL 75 was (2.83±1.10)%. When an image was enlarged to 4 times, precision doubled. There was no a difference in comparing RECIST to WHO in terms of response rate. Thus the best method was considered to be RECIST because of its convenience. (author)

  6. Enhanced experimental tumor metastasis with age in senescence-accelerated mouse

    International Nuclear Information System (INIS)

    Shimizu, Kosuke; Kinouchi Shimizu, Naomi; Asai, Tomohiro; Oku, Naoto; Tsukada, Hideo

    2008-01-01

    Tumor metastasis is affected by the host immune surveillance system. Since aging may attenuate the host immune potential, the experimental tumor metastasis may be enhanced with age. In the present study, we investigated this alteration of experimental tumor metastasis with age. We used senescence-accelerated mice prone 10 (SAMP10) as a model of aged animals. Natural killer cell (NK) activity, as an indicator of immune surveillance potential, in 8-month-old (aged) SAMP10 mice was observed to be much lower than that in 2-month-old (young) mice. When we examined the in vivo trafficking of lung-metastatic K1735M2 melanoma cells in SAMP10 with positron emission tomography (PET), K1735M2 cells labeled with [2- 18 F]2-deoxy-2-fluoro-D-glucose ([ 18 F]FDG) were observed in both young and aged SAMP10 just after injection of the cells, whereas the clearance of 18 F from the lungs was retarded in aged animals. The accumulation of 5-[ 125 I]iodo-2'-deoxyuridine ([ 125 I]IUdR)-labeled K1735M2 cells in the lungs of SAMP10 at 24 h after injection was significantly higher in aged mice. Corresponding to these results, the number of metastatic colonies in the lung was larger in the aged SAMP10 of the experimental tumor metastasis model. The present study demonstrated that the aging process produced a susceptible environment allowing the tumor cells to metastasize due to decrease in the host immune surveillance potential with age. (author)

  7. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  8. PET measurements of hyperthermia-induced suppression of protein synthesis in tumors in relation to effects on tumor growth

    International Nuclear Information System (INIS)

    Daemen, B.J.; Elsinga, P.H.; Mooibroek, J.; Paans, A.M.; Wieringa, A.R.; Konings, A.W.; Vaalburg, W.

    1991-01-01

    Hyperthermia-induced metabolic changes in tumor tissue have been monitored by PET. Uptake of L-[1-11C]tyrosine in rhabdomyosarcoma tissue of Wag/Rij rats was dose-dependently reduced after local hyperthermia treatment at 42, 45, or 47 degrees C. Tumor blood flow, as measured by PET with 13NH3, appeared to be unchanged. The L-[1-11C]tyrosine uptake data were compared to uptake data of L-[1-14C]tyrosine and with data on the incorporation of L-[1-14C]tyrosine into tumor proteins. After intravenous injection, the 14C data were obtained from dissected tumor tissue. Heat-induced inhibition of the incorporation of L-[1-14C]tyrosine into tumor proteins tallied with the L-[1-11C]tyrosine uptake data. Heat-induced inhibition of amino acid uptake in the tumor correlated well with regression of tumor growth. It is concluded that PET using L-[1-11C]tyrosine is eligible for monitoring the effect of hyperthermia on tumor growth

  9. Tumor hepático experimental (VX-2 em coelho: implantação do modelo no Brasil Experimental liver tumor (VX-2 in rabbits: implantation of the model in Brazil

    Directory of Open Access Journals (Sweden)

    Rogério Saad Hossne

    2002-08-01

    Full Text Available Os estudos para a investigação de novas modalidades terapêuticas em biologia tumoral, deveriam passar por estudos experimentais prévios. Neste sentido dispõem-se hoje de uma grande variedade de modelos tumorais experimentais; em determinadas investigações faz-se necessária a adequação do modelo tumoral às necessidades biológicas, patológicas e experimentais dos estudos. Desta forma, em nosso serviço, buscávamos um modelo tumoral hepático para estudos experimentais que se adequasse às seguintes características: fácil manipulação, crescimento controlável, evolução e agressividade semelhantes aos seres humanos. Os dados da literatura nos levaram a busca do tumor hepático VX-2, em coelhos. Neste artigo discutimos as vantagens da utilização deste modelo experimental e a sua introdução em nosso país.Studies for investigation of new therapeutic modalities in tumoral biology should be based on previous experimental studies. Then, there are a great variety of tumoral experimental models today. Some investigations have been done necessary an adaptation of the tumoral model to the needing of the studies biological and pathological. So, in our laboratory, we looked for a tumoral hepatic model for experimental studies with the following characteristics: easy manipulation, control of growing, evolution and aggressiveness like to humans. Data of the literature took us the search of the hepatic tumor VX-2, in rabbits. In this article we discussed the advantages of use this experimental model and its introduction in our country. Experimental hepatic tumor (VX-2 in rabbit. Implantation of the model in Brazil.

  10. Weak measurement and its experimental realisation

    International Nuclear Information System (INIS)

    Flack, R; Hiley, B J

    2014-01-01

    The relationship between the real part of the weak value of the momentum operator at a post selected position is discussed and the meaning of the experimentally determined stream-lines in the Toronto experiment of Kocsis et al is re-examined. We argue against interpreting the energy flow lines as photon trajectories. The possibility of performing an analogous experiment using atoms is proposed in order that a direct comparison can be made with the trajectories calculated by Philippidis, Dewdney and Hiley using the Bohm approach.

  11. Experimental study of chemical embolus therapy combined with radiotherapy for VX2 bone tumors

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Mochizuki, Kazuo; Ishii, Yoshiaki

    2000-01-01

    We conducted an experimental study, using a combination of coarse crystal cisplatin and radiotherapy for bone tumors, to evaluate the possibility of the clinical application of chemical embolus therapy in the field of orthopedic surgery. Experimental femoral bone tumors were produced, in rabbits, using VX2 carcinoma. The rabbits were allocated to five groups: untreated control, embolus, chemical embolus, irradiation alone, and chemical embolus and irradiation combination. These therapies were evaluated comparatively, in terms of local antitumor effects (including body weight, X-ray findings, angiography, and histopathology) and in terms of inhibition of pulmonary metastasis. Local antitumor effects, as evaluated by all parameters, except for body weight, were significantly greater for the chemical and irradiation combination group than for the chemical embolus, irradiation alone, untreated control, and embolus groups. There was no significant difference in the inhibition of pulmonary metastasis among the chemical embolus and irradiation combination, chemical embolus, and irradiation alone groups. These findings demonstrated the synergistic effect of the combination of chemical embolus therapy and radiotherapy. In this study, however, no significant difference was found between the chemical embolus therapy alone and the combination therapy groups in the inhibitory effect on pulmonary tumor metastasis, suggesting the need to conduct combination therapy repeatedly in the clinical setting. (author)

  12. Z0 decay modes - experimental measurements

    International Nuclear Information System (INIS)

    Dorfan, J.M.

    1984-08-01

    This report summarizes three lectures given at the Theoretical Advanced Study Institute at the University of Michigan at Ann Arbor. The lectures begin with an introduction to storage rings and linear colliders with special reference to the parameters of the SLC and LEP. The rigors of the Z 0 environment are presented along with the requirements for SLC and LEP detectors. The pedagogy needed for testing the Standard Model is developed, and some experimental tests of the Standard Model are discussed. Tests which involve extensions of the Standard Model (charged Higgs particles, more generations) as well as a few examples of how supersymmetry may show up at the Z 0 are discussed. 25 references, 34 figures

  13. Experimental tumor growth of canine osteosarcoma cell line on chick embryo chorioallantoic membrane (in vivo studies).

    Science.gov (United States)

    Walewska, Magdalena; Dolka, Izabella; Małek, Anna; Wojtalewicz, Anna; Wojtkowska, Agata; Żbikowski, Artur; Lechowski, Roman; Zabielska-Koczywąs, Katarzyna

    2017-05-12

    The chick embryo chorioallantoic membrane (CAM) model is extensively used in human medicine in preclinical oncological studies. The CAM model has several advantages: low cost, simple experimental approach, time saving and following "3R principles". Research has shown that the human osteosarcoma cell lines U2OS, MMNG-HOS, and SAOS can form tumors on the CAM. In veterinary medicine, this has been described only for feline fibrosarcomas, feline mammary carcinomas and canine osteosarcomas. However, in case of canine osteosarcomas, it has been shown that only non-adherent osteosarcoma stem cells isolated from KTOSA5 and CSKOS cell lines have the ability to form microtumors on the CAM after an incubation period of 5 days, in contrast to adherent KTOSA5 and CSKOS cells. In the presented study, we have proven that the commercial adherent canine osteosarcoma cell line (D-17) can form vascularized tumors on the CAM after the incubation period of 10 days.

  14. Measurements of operator performance - an experimental setup

    International Nuclear Information System (INIS)

    Netland, K.

    1980-01-01

    The human has to be considered as an important element in a process control system, even if the degree of automation is extremely high. Other elements, e.g. computer, displays, etc., can to a large extent be described and quantified. The human (operator), is difficult to describe in a precise way, and it is just as difficult to predict his thinking and acting in a control room environment. Many factors influence his performance, such as: experience, motivation, level of knowledge, training, control environment, job organization, etc. These factors have to a certain degree to be described before guidelines for design of the man-process interfaces and the control room layout can be developed. For decades, the psychological science has obtained knowledge of the human mind and behaviour. This knowledge should have the potential of a positive input on our effort to describe the factors influencing the operator performance. Even if the human is complex, a better understanding of his thinking and acting, and a more precise description of the factors influencing his performance can be obtained. At OECD Halden Reactor Project an experimental set-up for such studies has been developed and implemented in the computer laboratory. The present set-up includes elements as a computer- and display-based control room, a simulator representing a nuclear power plant, training programme for the subjects, and methods for the experiments. Set-up modules allow reconfiguration of experiments. (orig./HP)

  15. Measures of Situation Awareness: An Experimental Evaluation

    Science.gov (United States)

    1991-10-01

    occurrence from non- occurrence of the target event, referred to as sensitivity (Macmillan and Creelman , 1990). Because sensitivity declines if pilots are...Pollack and Norman, 1964; see also Craig, 1979; Macmillan and Creelman , 1990). Finally, avoidance failures were measured simply as the number of times...Wesley. Macmillan, N. A., & Creelman , C. D. (1990). Response bias: Characteristics of detection theory, threshold theory, and "non- parametric" indexes

  16. Mechanisms of tumor necrosis in photodynamic therapy with a chlorine photosensitizer: experimental studies

    Science.gov (United States)

    Privalov, Valeriy A.; Lappa, Alexander V.; Bigbov, Elmir N.

    2011-02-01

    A photodynamic therapy experiment on 118 inbred white mice with transplanted Ehrlich's tumor (mouse mammary gland adenocarcinoma) is performed to reveal mechanisms of necrosis formation. In 7-10 days the tumor of 1-1.5 cm diameter is formed under skin at the injection point, and PDT procedure is applied. There were used a chlorine type photosensitizer RadachlorineTM and 662 nm wavelength diode laser. The drug is injected by intravenously at the dose of 40 mg/kg; the irradiation is executed in 2-2.5 hours at the surface dose of about 200 J/cm2. Each of the mice had a photochemical reaction in form of destructive changes at the irradiation region with subsequent development of dry coagulation necrosis. After rejection of the necrosis there occurred epithelization of defect tissues in a tumor place. Histological investigations were conducted in different follow-up periods, in 5 and 30 min, 1, 3, 6, and 12 hours, 1, 3, 7 and 28 days after irradiation. They included optical microscopy, immune marker analysis, morphometry with measurements of volume density of epithelium, tumor stroma and necroses, vascular bed. The investigations showed that an important role in damaging mechanisms of photodynamic action belongs to hypoxic injuries of tumor mediated by micro vascular disorders and blood circulatory disturbances. The injuries are formed in a few stages: microcirculation angiospasm causing vessel paresis, irreversible stases in capillaries, diapedetic hemorrhages, thromboses, and thrombovasculitis. It is marked mucoid swelling and fibrinoid necrosis of vascular tissue. Progressive vasculitises result in total vessel obliteration and tumor necrosis.

  17. Experimental measurements of negative hydrogen ion production from surfaces

    International Nuclear Information System (INIS)

    Graham, W.G.

    1977-09-01

    Experimental measurements of the production of H - from surfaces bombarded with hydrogen are reviewed. Some measurements of H + and H 0 production from surfaces are also discussed with particular emphasis on work which might be relevant to ion source applications

  18. Dendritic cell-based vaccines for the therapy of experimental tumors

    Czech Academy of Sciences Publication Activity Database

    Piasecka, E.P.; Indrová, Marie

    2010-01-01

    Roč. 2, č. 2 (2010), s. 257-268 ISSN 1750-743X R&D Projects: GA AV ČR IAA500520807; GA ČR GA301/09/1024; GA MZd NS10660 Grant - others:Polish Ministry of Science and Higher Education(PL) NN401235334 Institutional research plan: CEZ:AV0Z50520514 Keywords : dendritic cells * preparation of vaccines * experimental tumors Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.542, year: 2010

  19. Metabolic 19F MRI an dynamic 18F PET for chemotherapy monitoring in experimental tumors

    International Nuclear Information System (INIS)

    Brix, G.; Haberkorn, U.; Bellemann, M.E.

    1999-01-01

    The efficient clinical use of chemotherapeutic agents requires the assessment of the uptake and metabolism of the drugs in the tumor as well as in the various organs of the body by using noninvasive imaging techniques such as magnetic resonance imaging (MRI) and positron emission tomography (PET). In this overview, we present different metabolic 19 F MRI and dynamic 18 F PET techniques for noninvasive monitoring of fluorine-containing anticancer drugs and evaluate their potentials and limitations within the framework of experimental animal studies. (orig.) [de

  20. A simple experimental setup for magneto-dielectric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C., E-mail: cvunom@hotmail.com

    2014-09-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities.

  1. A simple experimental setup for magneto-dielectric measurements

    International Nuclear Information System (INIS)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C.

    2014-01-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities

  2. Comparison of planar, PET and well-counter measurements of total tumor radioactivity in a mouse xenograft model.

    Science.gov (United States)

    Green, Michael V; Seidel, Jurgen; Williams, Mark R; Wong, Karen J; Ton, Anita; Basuli, Falguni; Choyke, Peter L; Jagoda, Elaine M

    2017-10-01

    Quantitative small animal radionuclide imaging studies are often carried out with the intention of estimating the total radioactivity content of various tissues such as the radioactivity content of mouse xenograft tumors exposed to putative diagnostic or therapeutic agents. We show that for at least one specific application, positron projection imaging (PPI) and PET yield comparable estimates of absolute total tumor activity and that both of these estimates are highly correlated with direct well-counting of these same tumors. These findings further suggest that in this particular application, PPI is a far more efficient data acquisition and processing methodology than PET. Forty-one athymic mice were implanted with PC3 human prostate cancer cells transfected with prostate-specific membrane antigen (PSMA (+)) and one additional animal (for a total of 42) with a control blank vector (PSMA (-)). All animals were injected with [ 18 F] DCFPyl, a ligand for PSMA, and imaged for total tumor radioactivity with PET and PPI. The tumors were then removed, assayed by well counting for total radioactivity and the values between these methods intercompared. PET, PPI and well-counter estimates of total tumor radioactivity were highly correlated (R 2 >0.98) with regression line slopes near unity (0.95radioactivity can be measured with PET or PPI with an accuracy comparable to well counting if certain experimental and pharmacokinetic conditions are met. In this particular application, PPI is significantly more efficient than PET in making these measurements. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  4. Experimental study of radiopharmaceuticals based on technetium-99m labeled derivative of glucose for tumor diagnosis

    Science.gov (United States)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.; Dergilev, A.

    2016-06-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 minutes at room temperature. After centrifugation of the vials with cells, the supernatant was removed. Radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B 1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 minutes. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D- glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3±0.15MBq and 1.07±0.6MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio- D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  5. Cerebral scintigraphy in dogs using gallium 67. Value in the investigation of experimental brain tumors

    International Nuclear Information System (INIS)

    Joffre, J.-F.

    1975-01-01

    The possibility of inducing experimental brain tumors in dogs by intracerebral inoculation of Rous sarcoma virus led to the development of an early diagnosis procedure without any danger for the carrier animal. Already widely used in humans, cerebral gammagraphy, used in dogs in the conditions developed, perfectly satisfy the requirements of harmlessness, precision and reliability. Scintiscans are taken 48 hours after injection of two mCi of carrier-free Ga 67 citrate. Profile and front patterns are obtained by means of a gamma camera connected to an on-line data processing system. Thirteen examinations were carried out under general anesthesia. Three dogs exhibiting positive scintiscan patterns revealed at the autopsy tumors ranging in size from a hazelnut to a walnut. The remaining animals gave negative or dubious patterns, and none of them revealed a tumor larger in size than a pea. The results obtained in this study are encouraging, and it is felt that this method can enable valid diagnosis of the presence of cerebral neoplasias in dogs, provided they are sufficiently large [fr

  6. Experimental measurements of shock properties of stishovite

    International Nuclear Information System (INIS)

    Furnish, M.D.; Ito, E.

    1996-01-01

    We have synthesized, characterized and performed Hugoniot measurements on monolithic samples of stishovite. Synthesis was accomplished in a multianvil press with pyrophyllite gaskets and carbon heaters. The samples had densities ranging from 3.80 to 4.07Mg/m 3 , corresponding to stishovite volume fractions of 0.7 to 0.87, a range confirmed by NMR analysis. They had no significant impurities except less than 1% carbon. Samples ∼1 mm thick and 3 mm diameter were tested in reverse- and forward-ballistics modes on a two-stage light gas gun, using velocity interferometry diagnostics. Impact velocities ranged from 4.0 to 6.5 km/sec. Hugoniot stresses for the four successful tests ranged from 65 to 225GPa. At higher stresses significant uncertainties arise due to impact tilt/nonplanarity issues. Results are consistent with earlier predictions of the stishovite Hugoniot based on quartz-centered Hugoniot data, static-compression (diamond-anvil cell) data and hydrostatic multianvil cell data. Release behavior appears to be frozen. These results are remarkable in view of the small size of the samples used. copyright 1996 American Institute of Physics

  7. Tumor hypoxia - A confounding or exploitable factor in interstitial brachytherapy? Effects of tissue trauma in an experimental rat tumor model

    NARCIS (Netherlands)

    van den Berg, AP; van Geel, CAJF; van Hooije, CMC; van der Kleij, AJ; Visser, AG

    2000-01-01

    Purpose: To evaluate the potential effects of tumor hypoxia induced by afterloading catheter implantation on the effectiveness of brachytherapy in a rat tumor model. Methods and Materials: Afterloading catheters (4) Here implanted in subcutaneously growing R1M rhabdomyosarcoma in female Wag/Rij

  8. EXPERIMENTAL RATIONALE FOR HEMOSTATIC SUTURES DURING RESECTION OF THE KIDNEY FOR ITS TUMOR

    Directory of Open Access Journals (Sweden)

    V. M. Popkov

    2014-08-01

    Full Text Available The investigation deals with the study of the biomechanical properties of renal tissues and the comparison of different hemostatic suture procedures used during resection of the kidney for its tumor. The performed experimental study allows one to recommend that a renal capsule as the organ’s most stable and plastic part must be necessarily inserted into the hemostatic suture on both sides. The elastic modulus (Young’s modulus serves as an integral indicator of the deformation-strength properties of renal tissues, which enables it to be recommended for the wider use in experimental and clinical studies. The proposed modified suture can minimize the number of postoperative bleedings from the renal parenchyma and reduce the time of surgery, thereby improving the results of organ-saving treatment in patients with kidney cancer.

  9. Pulmonary tumor measurements from x-ray computed tomography in one, two, and three dimensions.

    Science.gov (United States)

    Villemaire, Lauren; Owrangi, Amir M; Etemad-Rezai, Roya; Wilson, Laura; O'Riordan, Elaine; Keller, Harry; Driscoll, Brandon; Bauman, Glenn; Fenster, Aaron; Parraga, Grace

    2011-11-01

    We evaluated the accuracy and reproducibility of three-dimensional (3D) measurements of lung phantoms and patient tumors from x-ray computed tomography (CT) and compared these to one-dimensional (1D) and two-dimensional (2D) measurements. CT images of three spherical and three irregularly shaped tumor phantoms were evaluated by three observers who performed five repeated measurements. Additionally, three observers manually segmented 29 patient lung tumors five times each. Follow-up imaging was performed for 23 tumors and response criteria were compared. For a single subject, imaging was performed on nine occasions over 2 years to evaluate multidimensional tumor response. To evaluate measurement accuracy, we compared imaging measurements to ground truth using analysis of variance. For estimates of precision, intraobserver and interobserver coefficients of variation and intraclass correlations (ICC) were used. Linear regression and Pearson correlations were used to evaluate agreement and tumor response was descriptively compared. For spherical shaped phantoms, all measurements were highly accurate, but for irregularly shaped phantoms, only 3D measurements were in high agreement with ground truth measurements. All phantom and patient measurements showed high intra- and interobserver reproducibility (ICC >0.900). Over a 2-year period for a single patient, there was disagreement between tumor response classifications based on 3D measurements and those generated using 1D and 2D measurements. Tumor volume measurements were highly reproducible and accurate for irregular, spherical phantoms and patient tumors with nonuniform dimensions. Response classifications obtained from multidimensional measurements suggest that 3D measurements provide higher sensitivity to tumor response. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  10. Mechanoregulatory tumor-stroma crosstalk in pancreatic cancer: Measurements of the effects of extracellular matrix mechanics on tumor growth behavior, and vice-versa, to inform therapeutics

    Science.gov (United States)

    Celli, Jonathan; Jones, Dustin; El-Hamidi, Hamid; Cramer, Gwendolyn; Hanna, William; Caide, Andrew; Jafari, Seyedehrojin

    The rheological properties of the extracellular matrix (ECM) have been shown to play key roles in regulating tumor growth behavior through mechanotranduction pathways. The role of the mechanical microenvironment may be particularly important tumors of the pancreas, noted for an abundance of rigid fibrotic stroma, implicated in therapeutic resistance. At the same time, cancer cells and their stromal partners (e.g. tumor associated fibroblasts) continually alter the mechanical microenvironment in response to extracellular physical and biochemical cues as part of a two-way mechanoregulatory dialog. Here, we describe experimental studies using 3D pancreatic cell cultures with customized mechanical properties, combined with optical microrheology to provide insight into tumor-driven matrix remodeling. Quantitative microscopy provides measurements of phenotypic changes accompanying systematic variation of ECM composition in collagen and laminin-rich basement membrane admixtures, while analysis of the trajectories of passive tracer particles embedded in ECM report dynamic changes in heterogeneity, microstructure and local shear modulus accompanying both ECM stiffening (fibrosis) processes, and ECM degradation near invading cells. We gratefully acknowledge funding from the National Cancer Institute, R00CA155045 (PI: Celli).

  11. Tumor Volume Reduction Rate Measured by Magnetic Resonance Volumetry Correlated With Pathologic Tumor Response of Preoperative Chemoradiotherapy for Rectal Cancer

    International Nuclear Information System (INIS)

    Yeo, Seung-Gu; Kim, Dae Yong; Kim, Tae Hyun; Jung, Kyung Hae; Hong, Yong Sang; Chang, Hee Jin; Park, Ji Won; Lim, Seok-Byung; Choi, Hyo Seong; Jeong, Seung-Yong

    2010-01-01

    Purpose: To determine whether the tumor volume reduction rate (TVRR) measured using three-dimensional region-of-interest magnetic resonance volumetry correlates with the pathologic tumor response after preoperative chemoradiotherapy (CRT) for locally advanced rectal cancer. Methods and Materials: The study included 405 patients with locally advanced rectal cancer (cT3-T4) who had undergone preoperative CRT and radical proctectomy. The tumor volume was measured using three-dimensional region-of-interest magnetic resonance volumetry before and after CRT but before surgery. We analyzed the correlation between the TVRR and the pathologic tumor response in terms of downstaging and tumor regression grade (TRG). Downstaging was defined as ypStage 0-I (ypT0-T2N0M0), and the TRG proposed by Dworak et al. was used. Results: The mean TVRR was 65.0% ± 22.3%. Downstaging and complete regression occurred in 167 (41.2%) and 58 (14.3%) patients, respectively. The TVRRs according to ypT classification (ypT0-T2 vs. ypT3-T4), ypN classification (ypN0 vs. ypN1-N2), downstaging (ypStage 0-I vs. ypStage II-III), good regression (TRG 3-4 vs. TRG 1-2), and complete regression (TRG 4 vs. TRG 1-3) were all significantly different (p 80%), the rates of ypT0-T2, ypN0, downstaging, and good regression were all significantly greater for patients with a TVRR of ≥60%, as was the complete regression rate for patients with a TVRR >80% (p <.05). Conclusion: The TVRR measured using three-dimensional region-of-interest magnetic resonance volumetry correlated significantly with the pathologic tumor response in terms of downstaging and TRG after preoperative CRT for locally advanced rectal cancer.

  12. Method of hyperthermia and tumor size influence effectiveness of doxorubicin release from thermosensitive liposomes in experimental tumors.

    Science.gov (United States)

    Willerding, Linus; Limmer, Simone; Hossann, Martin; Zengerle, Anja; Wachholz, Kirsten; Ten Hagen, Timo L M; Koning, Gerben A; Sroka, Ronald; Lindner, Lars H; Peller, Michael

    2016-01-28

    Systemic chemotherapy of solid tumors could be enhanced by local hyperthermia (HT) in combination with thermosensitive liposomes (TSL) as drug carriers. In such an approach, effective HT of the tumor is considered essential for successful triggering local drug release and targeting of the drug to the tumor. To investigate the effect of HT method on the effectiveness of drug delivery, a novel laser-based HT device designed for the use in magnetic resonance imaging (MRI) was compared systematically with the frequently used cold light lamp and water bath HT. Long circulating phosphatidyldiglycerol-based TSL (DPPG2-TSL) with encapsulated doxorubicin (DOX) were used as drug carrier enabling intravascular drug release. Experiments were performed in male Brown Norway rats with a syngeneic soft tissue sarcoma (BN 175) located on both hind legs. One tumor was heated while the second tumor remained unheated as a reference. Six animals were investigated per HT method. DPPG2-TSL were injected i.v. at a stable tumor temperature above 40°C. Thereafter, temperature was maintained for 60min. Total DOX concentration in plasma, tumor tissue and muscle was determined post therapy by HPLC. Finally, the new laser-based device was tested in a MRI environment at 3T using DPPG2-TSL with encapsulated Gd-based contrast agent. All methods showed effective DOX delivery by TSL with 4.5-23.1ng/mg found in the heated tumors. In contrast, DOX concentration in the non-heated tumors was 0.5±0.1ng/mg. Independent of used HT methods, higher DOX levels were found in the smaller tumors. In comparison water bath induced lowest DOX delivery but still showing fourfold higher DOX concentrations compared to the non-heated tumors. With the laser-based applicator, a 13 fold higher DOX deposition was possible for large tumors and a 15 fold higher for the small tumors, respectively. Temperature gradients in the tumor tissue were higher with the laser and cold light lamp (-0.3°C/mm to -0.5°C/mm) compared to

  13. Action of hexachlorobenzene on tumor growth and metastasis in different experimental models

    International Nuclear Information System (INIS)

    Pontillo, Carolina Andrea; Rojas, Paola; Chiappini, Florencia; Sequeira, Gonzalo; Cocca, Claudia; Crocci, Máximo; Colombo, Lucas; Lanari, Claudia

    2013-01-01

    Hexachlorobenzene (HCB) is a widespread organochlorine pesticide, considered a possible human carcinogen. It is a dioxin-like compound and a weak ligand of the aryl hydrocarbon receptor (AhR). We have found that HCB activates c-Src/HER1/STAT5b and HER1/ERK1/2 signaling pathways and cell migration, in an AhR-dependent manner in MDA-MB-231 breast cancer cells. The aim of this study was to investigate in vitro the effect of HCB (0.005, 0.05, 0.5, 5 μM) on cell invasion and metalloproteases (MMPs) 2 and 9 activation in MDA-MB-231 cells. Furthermore, we examined in vivo the effect of HCB (0.3, 3, 30 mg/kg b.w.) on tumor growth, MMP2 and MMP9 expression, and metastasis using MDA-MB-231 xenografts and two syngeneic mouse breast cancer models (spontaneous metastasis using C4-HI and lung experimental metastasis using LM3). Our results show that HCB (5 μM) enhances MMP2 expression, as well as cell invasion, through AhR, c-Src/HER1 pathway and MMPs. Moreover, HCB increases MMP9 expression, secretion and activity through a HER1 and AhR-dependent mechanism, in MDA-MB-231 cells. HCB (0.3 and 3 mg/kg b.w.) enhances subcutaneous tumor growth in MDA-MB-231 and C4-HI in vivo models. In vivo, using MDA-MB-231 model, the pesticide (0.3, 3 and 30 mg/kg b.w.) activated c-Src, HER1, STAT5b, and ERK1/2 signaling pathways and increased MMP2 and MMP9 protein levels. Furthermore, we observed that HCB stimulated lung metastasis regardless the tumor hormone-receptor status. Our findings suggest that HCB may be a risk factor for human breast cancer progression. - Highlights: ► HCB enhances MMP2 and MMP9 expression and cell invasion in MDA-MB-231, in vitro. ► HCB-effects are mediated through AhR, HER1 and/or c-Src. ► HCB increases subcutaneous tumor growth in MDA-MB-231 and C4-HI in vivo models. ► HCB activates c-Src/HER1 pathway and increases MMPs levels in MDA-MB-231 tumors. ► HCB stimulates lung metastasis in C4-HI and LM3 in vivo models

  14. Action of hexachlorobenzene on tumor growth and metastasis in different experimental models

    Energy Technology Data Exchange (ETDEWEB)

    Pontillo, Carolina Andrea, E-mail: caroponti@hotmail.com [Laboratorio de Efectos Biológicos de Contaminantes Ambientales, Departamento de Bioquímica Humana, Facultad de Medicina, Universidad de Buenos Aires, Buenos Aires (Argentina); Rojas, Paola, E-mail: parojas2010@gmail.com [Laboratorio de Carcinogénesis Hormonal, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Buenos Aires (Argentina); Chiappini, Florencia, E-mail: florenciachiappini@hotmail.com [Laboratorio de Efectos Biológicos de Contaminantes Ambientales, Departamento de Bioquímica Humana, Facultad de Medicina, Universidad de Buenos Aires, Buenos Aires (Argentina); Sequeira, Gonzalo, E-mail: chicon27_7@hotmail.com [Laboratorio de Carcinogénesis Hormonal, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Buenos Aires (Argentina); Cocca, Claudia, E-mail: cm_cocca@hotmail.com [Laboratorio de Radioisótopos, Facultad de Farmacia y Bioquímica, Universidad de Buenos Aires, Buenos Aires (Argentina); Crocci, Máximo, E-mail: info@crescenti.com.ar [Instituto de Inmunooncología Crescenti, Buenos Aires (Argentina); Colombo, Lucas, E-mail: lucascol2003@yahoo.com.ar [Instituto de Oncología Angel Roffo, Universidad de Buenos Aires, Buenos Aires,Argentina (Argentina); Lanari, Claudia, E-mail: lanari.claudia@gmail.com [Laboratorio de Carcinogénesis Hormonal, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Buenos Aires (Argentina); and others

    2013-05-01

    Hexachlorobenzene (HCB) is a widespread organochlorine pesticide, considered a possible human carcinogen. It is a dioxin-like compound and a weak ligand of the aryl hydrocarbon receptor (AhR). We have found that HCB activates c-Src/HER1/STAT5b and HER1/ERK1/2 signaling pathways and cell migration, in an AhR-dependent manner in MDA-MB-231 breast cancer cells. The aim of this study was to investigate in vitro the effect of HCB (0.005, 0.05, 0.5, 5 μM) on cell invasion and metalloproteases (MMPs) 2 and 9 activation in MDA-MB-231 cells. Furthermore, we examined in vivo the effect of HCB (0.3, 3, 30 mg/kg b.w.) on tumor growth, MMP2 and MMP9 expression, and metastasis using MDA-MB-231 xenografts and two syngeneic mouse breast cancer models (spontaneous metastasis using C4-HI and lung experimental metastasis using LM3). Our results show that HCB (5 μM) enhances MMP2 expression, as well as cell invasion, through AhR, c-Src/HER1 pathway and MMPs. Moreover, HCB increases MMP9 expression, secretion and activity through a HER1 and AhR-dependent mechanism, in MDA-MB-231 cells. HCB (0.3 and 3 mg/kg b.w.) enhances subcutaneous tumor growth in MDA-MB-231 and C4-HI in vivo models. In vivo, using MDA-MB-231 model, the pesticide (0.3, 3 and 30 mg/kg b.w.) activated c-Src, HER1, STAT5b, and ERK1/2 signaling pathways and increased MMP2 and MMP9 protein levels. Furthermore, we observed that HCB stimulated lung metastasis regardless the tumor hormone-receptor status. Our findings suggest that HCB may be a risk factor for human breast cancer progression. - Highlights: ► HCB enhances MMP2 and MMP9 expression and cell invasion in MDA-MB-231, in vitro. ► HCB-effects are mediated through AhR, HER1 and/or c-Src. ► HCB increases subcutaneous tumor growth in MDA-MB-231 and C4-HI in vivo models. ► HCB activates c-Src/HER1 pathway and increases MMPs levels in MDA-MB-231 tumors. ► HCB stimulates lung metastasis in C4-HI and LM3 in vivo models.

  15. Experimental measurements and mathematics; Les mesures experimentales et les mathematiques

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, I.; Bruno, S.; Durand, O.; Gaillard, P.; Lagrange, J.M.; Lamy, F.; Peyrat, J.P. [CEA Bruyeres-le-Chatel, 91 (France); Choux, A.; Druoton, L.; Pascal, G.; Sulpice, F. [CEA Valduc, 21 - Is-sur-Tille (France); Busvelle, E.; Garnier, L. [Universite de Bourgogne, Lab. d' Electronique, Informatique et Image, 21 - Dijon (France); Gauthier, J.P. [Laboratoire des Sciences de l' Information et des Systemes, 83 - Toulon (France); Langevin, R. [Institut Mathematique de Bourgogne, 21 - Dijon (France)

    2011-01-15

    Many problems that appear in experimental works can be solved by using mathematical methods, from the conception phase to the interpretation of measurements. We illustrate the use of these methods at CEA-DAM by pointing out some examples in 3 typical domains: treatment of experimental data, geometrical controls of targets, and analysis of a huge quantity of data. (authors)

  16. Overhead traveling crane vibration research using experimental wireless measuring system

    Directory of Open Access Journals (Sweden)

    Tomasz HANISZEWSKI

    2013-01-01

    Full Text Available The paper contains an operations and constructions description of theexperimental wireless measuring system for measuring accelerations in bridge cranes,based on PHIDGET 1056 sensors. Developed experimental research and measuringmethodology allows the use of the proposed wireless system on other cranesconstructions. The paper also shows examples of the results of vibration measurementsand FFT spectra, obtained on the basis of accelerations measurements.

  17. Further characterization of the adhesive-tumor-cell culture system for measuring the radiosensitivity of human tumor primary cultures

    International Nuclear Information System (INIS)

    Brock, W.A.; Bock, S.P.; Williams, M.; Baker, F.L.

    1987-01-01

    This study extends the use of the adhesive-tumor-cell culture system to include: over 100 sensitivity measurements at 2.0 Gy; tumorgenicity determinations in nude mice; and flow cytometry of the cells grown in the system. The malignant nature of the growing cells was proved by injecting cells into nude mice. Tumors resulted in 60% of the cases and the histology of each xenograft was similar to that of the human tumor. Flow cytometry was used to obtain DNA histograms of the original cell suspension and of cultures during the two week culture period in order to obtain quantitative information about the growth of aneuploid versus diploid populations. The results thus far demonstrate that 95% of aneuploid populations yield aneuploid growth; of the first 20 cases studied, only one suspension with an aneuploid peak resulted in diploid growth. Of further interest was the observation that it is not unusual for a minor aneuploid population to become the predominate growth fraction after two weeks in culture. These results demonstrate that the adhesive-tumor-cell culture system supports the growth of malignant cells, that multiple cell populations exist in cell suspensions derived from solid tumors, and that differences exist between the radiosensitivity of cells at 2.0 Gy in different histology types

  18. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  19. Antioxidant oils and Salmonella enterica Typhimurium reduce tumor in an experimental model of hepatic metastasis

    Directory of Open Access Journals (Sweden)

    Sorenson BS

    2011-05-01

    Full Text Available Brent S Sorenson, Kaysie L Banton, Lance B Augustin, Arnold S Leonard, Daniel A SaltzmanDepartment of Surgery, University of Minnesota Medical School, Minneapolis, MN, USAAbstract: Fruit seeds high in antioxidants have been shown to have anticancer properties and enhance host protection against microbial infection. Recently we showed that a single oral dose of Salmonella enterica serovar Typhimurium expressing a truncated human interleukin-2 gene (SalpIL2 is avirulent, immunogenic, and reduces hepatic metastases through increased natural killer cell populations in mice. To determine whether antioxidant compounds enhance the antitumor effect seen in SalpIL2-treated animals, we assayed black cumin (BC, black raspberry (BR, and milk thistle (MT seed oils for the ability to reduce experimental hepatic metastases in mice. In animals without tumor, BC and BR oil diets altered the kinetics of the splenic lymphocyte response to SalpIL2. Consistent with previous reports, BR and BC seed oils demonstrated independent antitumor properties and moderate adjuvant potential with SalpIL2. MT oil, however, inhibited the efficacy of SalpIL2 in our model. Based on these data, we conclude that a diet high in antioxidant oils promoted a more robust immune response to SalpIL2, thus enhancing its antitumor efficacy.Keywords: antioxidants, colorectal cancer, tumor models, metastasis

  20. Comparison of one-, two-, and three-dimensional measurements of childhood brain tumors.

    Science.gov (United States)

    Warren, K E; Patronas, N; Aikin, A A; Albert, P S; Balis, F M

    2001-09-19

    End points for assessing drug activity in brain tumors are determined by measuring the change in tumor size by magnetic resonance imaging (MRI) relative to a pretreatment or best-response scan. Traditionally, two-dimensional (2D) tumor measurements have been used, but one-dimensional (1D) measurements have recently been proposed as an alternative. Because software to estimate three-dimensional (3D) tumor volume from digitized MRI images is available, we compared all three methods of tumor measurement for childhood brain tumors and clinical outcome. Tumor size from 130 MRI scans from 32 patients (32 baseline and 98 follow-up scans, for a total of 130 scans; median, three scans per patient; range, two to 18 scans) was measured by each method. Tumor-response category (partial response, minor response, stable disease, or progressive disease) was determined from the percentage change in tumor size between the baseline or best-response scan and follow-up scans. Time to clinical progression was independently determined by chart review. All statistical tests were two-sided. Concordances between 1D and 2D, 1D and 3D, and 2D and 3D were 83% (95% confidence interval [CI] = 67% to 99%), 61% (95% CI = 47% to 75%), and 66% (95% CI = 52% to 80%), respectively, on follow-up scans. Concordances for 1D and 3D and for 2D and 3D were statistically significantly lower than the concordance for 1D and 2D (Ptumors in the minor response and progressive-disease categories. Median times to progression measured by the 1D, 2D, and 3D methods were 154, 105, and 112 days, respectively, compared with 114 days based on neurologic symptoms and signs (P = .09 for overall comparison). Detection of partial responses was not influenced by the measurement method, but estimating time to disease progression may be method dependent for childhood brain tumors.

  1. Comparison of planar, PET and well-counter measurements of total tumor radioactivity in a mouse xenograft model

    International Nuclear Information System (INIS)

    Green, Michael V.; Seidel, Jurgen; Williams, Mark R.; Wong, Karen J.; Ton, Anita; Basuli, Falguni; Choyke, Peter L.; Jagoda, Elaine M.

    2017-01-01

    Introduction: Quantitative small animal radionuclide imaging studies are often carried out with the intention of estimating the total radioactivity content of various tissues such as the radioactivity content of mouse xenograft tumors exposed to putative diagnostic or therapeutic agents. We show that for at least one specific application, positron projection imaging (PPI) and PET yield comparable estimates of absolute total tumor activity and that both of these estimates are highly correlated with direct well-counting of these same tumors. These findings further suggest that in this particular application, PPI is a far more efficient data acquisition and processing methodology than PET. Methods: Forty-one athymic mice were implanted with PC3 human prostate cancer cells transfected with prostate-specific membrane antigen (PSMA (+)) and one additional animal (for a total of 42) with a control blank vector (PSMA (−)). All animals were injected with [ 18 F] DCFPyl, a ligand for PSMA, and imaged for total tumor radioactivity with PET and PPI. The tumors were then removed, assayed by well counting for total radioactivity and the values between these methods intercompared. Results: PET, PPI and well-counter estimates of total tumor radioactivity were highly correlated (R 2 > 0.98) with regression line slopes near unity (0.95 < slope ≤ 1.02) and intercepts near zero (−0.001 MBq ≤ intercept ≤0.004 MBq). Conclusion: Total mouse xenograft tumor radioactivity can be measured with PET or PPI with an accuracy comparable to well counting if certain experimental and pharmacokinetic conditions are met. In this particular application, PPI is significantly more efficient than PET in making these measurements.

  2. Experimentally induced tumors used for angiographic estimation of embolisation and cytostatic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Strecker, E P; Kraus, W; Fiebig, H H; Kauffmann, G; Hauenstein, K H

    1982-02-01

    In 12 rats tumors have been induced chemically by intraperitoneal application of dimethylnitrosamine. This method is simple and reliable and the effect of tumor embolization can be followed easily. Thymus aplastic nude mice with transplanted human tumors deserve strict care. Tumor microangiograms of 48 animals demonstrate a close similarity with angiograms of corresponding human tumors. The vascular pattern does not alterate after several transplantations, after cytostatic therapy a slight hypervascularisation developes.

  3. Preoperative measurement of canine primary bone tumors, using radiography and bone scintigraphy

    International Nuclear Information System (INIS)

    Lamb, C.R.; Berg, J.; Bengston, A.E.

    1990-01-01

    Specimens of 20 canine primary bone tumors (18 osteosarcoma, 2 fibrosarcoma) were examined to compare the maximal axial length of gross tumor with the length of the lesion seen on preoperative radiographs and 99mTc methylene diphosphonate bone scintigraphic images. Radiographs defined the length of the tumor to within +/- 10% of the gross measurement for 6 (30%), underestimated it for 12 (60%), and overestimated it for 2 (10%) specimens. Bone scintigraphy defined tumor length within +/- 10% for 8 (40%), underestimated it for 1 (5%), and overestimated it for the remaining 11 (55%) specimens. Use of radiographic evaluation alone could result in underestimation of the diaphyseal extent of a primary bone tumor, with risk of incomplete resection. Bone scan images tend to overestimate tumor length and, therefore, may provide safer resection guidelines

  4. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    Science.gov (United States)

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The fibrinolytic system facilitates tumor cell migration across the blood-brain barrier in experimental melanoma brain metastasis

    International Nuclear Information System (INIS)

    Perides, George; Zhuge, Yuzheng; Lin, Tina; Stins, Monique F; Bronson, Roderick T; Wu, Julian K

    2006-01-01

    Patients with metastatic tumors to the brain have a very poor prognosis. Increased metastatic potential has been associated with the fibrinolytic system. We investigated the role of the fibrinolytic enzyme plasmin in tumor cell migration across brain endothelial cells and growth of brain metastases in an experimental metastatic melanoma model. Metastatic tumors to the brain were established by direct injection into the striatum or by intracarotid injection of B16F10 mouse melanoma cells in C57Bl mice. The role of plasminogen in the ability of human melanoma cells to cross a human blood-brain barrier model was studied on a transwell system. Wild type mice treated with the plasmin inhibitor epsilon-aminocaproic acid (EACA) and plg -/- mice developed smaller tumors and survived longer than untreated wild type mice. Tumors metastasized to the brain of wild type mice treated with EACA and plg -/- less efficiently than in untreated wild type mice. No difference was observed in the tumor growth in any of the three groups of mice. Human melanoma cells were able to cross the human blood-brain barrier model in a plasmin dependent manner. Plasmin facilitates the development of tumor metastasis to the brain. Inhibition of the fibrinolytic system could be considered as means to prevent tumor metastasis to the brain

  6. Regional glucose utilization and blood flow in experimental brain tumors studied by double tracer autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Kato, A.; Sako, K.; Diksic, M.; Yamamoto, Y.L.; Feindel, W.

    1985-01-01

    Coupling of regional glucose utilization (GLU) and blood flow (CBF) was examined in rats with implanted brain tumors (AA ascites tumor) by quantitative double tracer autoradiography using YF-2-fluorodeoxyglucose and 14C-iodoantipyrine. Four to 13 days after implantation, the animals were injected with the two tracers to obtain autoradiograms from the same brain section before and after the decay of YF. The autoradiograms were then analyzed by an image processor to obtain a metabolic coupling index (MCI = GLU/CBF). In the tumor, high GLU and low CBF were uncoupled to give a high MCI which implied anerobic glycolysis. In large tumors, the CBF was even lower. In the peri-tumoral region, GLU was reduced and reduction was lowest around the larger tumors. CBF in the peri-tumoral region was also reduced, but this reduction became less as the distance from the tumor margin increased. The GLU and CBF of white matter was little influenced by the presence of tumors except for some reduction in these values in relation to the larger tumors. The MCI in the tumor was higher than in the cortex of the same as well as the opposite hemisphere. These findings indicate that the metabolism and blood flow of the tumor and surrounding brain are variable and directly related to tumor size.

  7. Microspheres labelled with short-lived isotopes: Development and application for tumors treatment (Experimental study)

    International Nuclear Information System (INIS)

    Drozdovsky, B.Y.; Rosiev, R.A.; Goncharova, A.Y.; Skvortsov, V.G.; Petriev, V.M.; Grigoriev, A.N.; Schischkanov, N.G.

    1997-01-01

    Analysis of the conducted studies strongly suggests the possibility of usage of the domestic protein microspheres as a vehicle for radionuclide. The neutron-activating method of RPP production enables to utilize a broad spectrum of short-living isotopes that can be delivered into the target organ and anchored there for a long time. Good treatment results were obtained in case of the experimentally induced rheumatoid arthritis in rats after intraarticular loading of 165 Dy-hMSA. Mathematical calculations show that homogeneous distribution of RPP in human articulation cavity with the square of 100 cm 2 can be achieved when the quantity of administered particles exceeds 3000. On the example of 165 Dy-hMSA energy characteristic distribution we demonstrated that the absorbed dose for damaged cells at 2mm distance from the radioactive source is 7 times less than the one for a sphere of 2mm diameter. Analysis of dosimetric data in case of intratumoral loading of 165 Dy-hMSA also point out the necessity of the absorbed dose calculation methods taking into account the distance from the source and possible heterogeneity of RPP distribution inside the tumor to be employed. The prolonged RPP detention in the target causing no essential morphological and functional changes was achieved by embolization on the level of septal and interlobular arteries and of efferent arterioles in the animal's renal. The uniformity of microsphere distribution in the organ and their accumulation in tumors depends on the number of particles being administered. Investigations carried out suggest the efficacy of radionuclide therapy application for treatment of oncological and heavy somatic diseases. They also indicate the necessity of further investigations aimed to optimize the usage of microspheres as a radionuclide carrier usage and to work out the criteria of dosimetric planning

  8. Microspheres labelled with short-lived isotopes: Development and application for tumors treatment (Experimental study)

    Energy Technology Data Exchange (ETDEWEB)

    Drozdovsky, B.Y.; Rosiev, R.A.; Goncharova, A.Y.; Skvortsov, V.G.; Petriev, V.M.; Grigoriev, A.N.; Schischkanov, N.G. [Medical Radiological Research Centre RAMS, Kaluga Region, (Russian Federation)

    1997-10-01

    Analysis of the conducted studies strongly suggests the possibility of usage of the domestic protein microspheres as a vehicle for radionuclide. The neutron-activating method of RPP production enables to utilize a broad spectrum of short-living isotopes that can be delivered into the target organ and anchored there for a long time. Good treatment results were obtained in case of the experimentally induced rheumatoid arthritis in rats after intraarticular loading of {sup 165}Dy-hMSA. Mathematical calculations show that homogeneous distribution of RPP in human articulation cavity with the square of 100 cm{sup 2} can be achieved when the quantity of administered particles exceeds 3000. On the example of {sup 165}Dy-hMSA energy characteristic distribution we demonstrated that the absorbed dose for damaged cells at 2mm distance from the radioactive source is 7 times less than the one for a sphere of 2mm diameter. Analysis of dosimetric data in case of intratumoral loading of {sup 165}Dy-hMSA also point out the necessity of the absorbed dose calculation methods taking into account the distance from the source and possible heterogeneity of RPP distribution inside the tumor to be employed. The prolonged RPP detention in the target causing no essential morphological and functional changes was achieved by embolization on the level of septal and interlobular arteries and of efferent arterioles in the animal`s renal. The uniformity of microsphere distribution in the organ and their accumulation in tumors depends on the number of particles being administered. Investigations carried out suggest the efficacy of radionuclide therapy application for treatment of oncological and heavy somatic diseases. They also indicate the necessity of further investigations aimed to optimize the usage of microspheres as a radionuclide carrier usage and to work out the criteria of dosimetric planning 25 refs.

  9. [Synergistic effect of cell kinetics-directed chemo-endocrine therapy on experimental mammary tumors].

    Science.gov (United States)

    Ueki, H

    1987-11-01

    We tried to demonstrate that the cell kinetics-directed chemoendocrine therapy is more effective on hormone dependent breast cancer than empirical combination of the endocrine therapy and chemotherapy. Cell kinetics of each tumor was measured by flow cytometric analysis. Estrogen dependent human breast cancer cell line MCF-7 was used in vitro. In vivo, androgen dependent SC-115 carcinoma was transplanted to DDS mice. In vitro, tamoxifen was administered as the endocrine therapy. In vivo, we carried out testectomy on DDS mice. Effect of the endocrine therapy on the cell kinetics of the tumor was thought to be G1-S depression. High density 5FU was administered as the chemotherapeutic agents, whose content was 1 microgram/ml in vitro and 40 mg/kg in vivo. 5FU brought temporary decrease of cells in S phase. Only anteceding 5FU administration had synergistic effect in combination of 5FU and the endocrine therapy. 5FU was convinced to act more effectively on cells in S phase, so it was shown that cell kinetics-directed schedule was superior to the empirical treatment schedule in chemoendocrine therapy.

  10. Experimental study of 99Tcm-tri-peptide as a novel tumor imaging agent

    International Nuclear Information System (INIS)

    Xie Wenhui; Cai Xiaojia; Liu Ciyi; Zeng Jun; Zhang Lihua; Lei Bei; Huang Gang

    2011-01-01

    Objective: To evaluate 99 Tc m -Arg-Glu-Ser ( 99 Tc m -RES) as a potential tumor imaging agent. Methods: RES was synthesized using solid phase peptide synthesis. The optimal labeling conditions of RES were determined under different reagents and reacting temperatures using SnC1 2 as reducing agent.The biodistribution of 99 Tc m -RES was studied in nude mice bearing human lung cancer A549. Results: The radiochemical purity of 99 Tc m -RES was up to 85% and the radiochemical purity was 75% ever after 6 h at room temperature. The tumor uptake of 99 Tc m -RES was obvious and the radioactivity ratios of tumor/blood, tumor/heart, tumor/liver, tumor/lung, tumor/spleen and tumor/muscle were 5.31, 1.88, 1.57, 3.58, 4.16 and 5.92, respectively at 6 h after 99 Tc m -RES injection. Gamma camera imaging showed that tumor uptake of 99 Tc m -RES was negative in rabbits with inflammatory mass but positive in those bearing tumor. The radioactivity ratio of tumor/inflammation was 3.12 at 6 h after injection. Conclusion: 99 Tc m -RES might possibly become a potential tumor imaging agent. (authors)

  11. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  12. Comparison of continuous versus categorical tumor measurement-based metrics to predict overall survival in cancer treatment trials

    Science.gov (United States)

    An, Ming-Wen; Mandrekar, Sumithra J.; Branda, Megan E.; Hillman, Shauna L.; Adjei, Alex A.; Pitot, Henry; Goldberg, Richard M.; Sargent, Daniel J.

    2011-01-01

    Purpose The categorical definition of response assessed via the Response Evaluation Criteria in Solid Tumors has documented limitations. We sought to identify alternative metrics for tumor response that improve prediction of overall survival. Experimental Design Individual patient data from three North Central Cancer Treatment Group trials (N0026, n=117; N9741, n=1109; N9841, n=332) were used. Continuous metrics of tumor size based on longitudinal tumor measurements were considered in addition to a trichotomized response (TriTR: Response vs. Stable vs. Progression). Cox proportional hazards models, adjusted for treatment arm and baseline tumor burden, were used to assess the impact of the metrics on subsequent overall survival, using a landmark analysis approach at 12-, 16- and 24-weeks post baseline. Model discrimination was evaluated using the concordance (c) index. Results The overall best response rates for the three trials were 26%, 45%, and 25% respectively. While nearly all metrics were statistically significantly associated with overall survival at the different landmark time points, the c-indices for the traditional response metrics ranged from 0.59-0.65; for the continuous metrics from 0.60-0.66 and for the TriTR metrics from 0.64-0.69. The c-indices for TriTR at 12-weeks were comparable to those at 16- and 24-weeks. Conclusions Continuous tumor-measurement-based metrics provided no predictive improvement over traditional response based metrics or TriTR; TriTR had better predictive ability than best TriTR or confirmed response. If confirmed, TriTR represents a promising endpoint for future Phase II trials. PMID:21880789

  13. MR staging of malignant musculoskeletal tumors: An experimental study on MR and pathologic correlation of rabbit VX-2 carcinoma

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Chung, Sung Hoon; KIm, Cheol Woo; Kim, Seong Moon; Im, Jung Gi; Han, Man Chung

    1993-01-01

    To evaluate the reliability of MR imaging in tissue characterization and depiction of tumor boundaries, we performed MR pathologic correlation using parosteally implanted VX-2 carcinoma in 17 rabbit thighs. T1-weighted, T2-weighted and Gd-DTPA enhanced T1-weighted axial images were obtained 10-30 days after tumor implantation. After the animals were killed, frozen and sectioned along the MR imaging planes, and histopathologic examination were done. For accurate MR pathologic correlation, rabbit were fixed on the cardboard plate to minimize position change during the procedure. Tumor boundaries depicted on MR images were larger than those depicted on the specimen. Small tumors were surrounded by capsule-like loose connective tissue. Loose connective tissue became compact with tumor growth. This connective tissue showed high signal intensity on both T2-weighted and Gd-DTPA enhanced T1-weighted images. Muscle atrophy with fatty tissue accumulation around the tumor also contributed to the high signal intensity on MR images. Peritumoral edema and inflammatory reaction were not remarkable. Six of 8 cases with bone marrow fibrosis were detected on MR images. We concluded that peritumoral loose connective tissue and muscle atrophy exaggerated the size of experimentally induced malignant musculoskeletal tumors on MR images

  14. Green tea, red wine and lemon extracts reduce experimental tumor growth and cancer drug toxicity.

    Science.gov (United States)

    Zaletok, S P; Gulua, L; Wicker, L; Shlyakhovenko, V A; Gogol, S; Orlovsky, O; Karnaushenko, O V; Verbinenko, A; Milinevska, V; Samoylenko, O; Todor, I; Turmanidze, T

    2015-12-01

    To evaluate antitumor effect of plant polyphenol extracts from green tea, red wine lees and/or lemon peel alone and in combination with antitumor drugs on the growth of different transplanted tumors in experimental animals. Green tea extract (GTE) was prepared from green tea infusion. GTE-based composites of red wine (GTRW), lemon peel (GTRWL) and/or NanoGTE as well as corresponding nanocomposites were prepared. The total polyphenolics of the different GTE-based extracts ranged from 18.0% to 21.3%. The effects of GTE-based extracts were studied in sarcoma 180, Ehrlich carcinoma, B16 melanoma, Ca755 mammary carcinoma, P388 leukemia, L1210 leukemia, and Guerin carcinoma (original, cisplatin-resistant and doxorubicin-resistant variants). The extracts were administered as 0.1% solution in drinking water (0.6-1.0 mg by total polyphenolics per mouse per day and 4.0-6.3 mg per rat per day). Tumor growth inhibition (TGI) in mice treated with NanoGTE, cisplatin or cisplatin + NanoGTE was 27%, 55% and 78%, respectively, in Sarcoma 180%, 21%, 45% and 59%, respectively, in Ehrlich carcinoma; and 8%, 13% and 38%, respectively in B16 melanoma. Composites of NanoGTE, red wine, and lemon peel (NanoGTRWL) enhanced the antitumor effects of cyclophosphamide in mice with Ca755 mammary carcinoma. The treatment with combination of NanoGTE and inhibitors of polyamines (PA) synthesis (DFMO + MGBG) resulted in significant TGI of P388 leukemia (up to 71%) and L1210 leukemia. In rats transplanted with Guerin carcinoma (parental strain), treatment with GTRW or GTE alone resulted in 25-28% TGI vs. 55-68% TGI in cisplatin-treated animals. The inhibition observed in the case of combination of GTE or GTRW with cisplatin was additive giving 81-88% TGI. Similar effects were observed when combinations of the cytostatics with GTE (or NanoGTE) were tested against cisplatin- or doxorubicin-resistant Guerin carcinoma. Moreover, the plant extracts lowered side toxicity of the drugs. Treatment with GTE

  15. A measure of state persecutory ideation for experimental studies.

    Science.gov (United States)

    Freeman, Daniel; Pugh, Katherine; Green, Catherine; Valmaggia, Lucia; Dunn, Graham; Garety, Philippa

    2007-09-01

    Experimental research is increasingly important in developing the understanding of paranoid thinking. An assessment measure of persecutory ideation is necessary for such work. We report the reliability and validity of the first state measure of paranoia: The State Social Paranoia Scale. The items in the measure conform to a recent definition in which persecutory thinking has the 2 elements of feared harm and perpetrator intent. The measure was tested with 164 nonclinical participants and 21 individuals at high risk of psychosis with attenuated positive symptoms. The participants experienced a social situation presented in virtual reality and completed the new measure. The State Social Paranoia Scale was found to have excellent internal reliability, adequate test-retest reliability, clear convergent validity as assessed by both independent interviewer ratings and self-report measures, and showed divergent validity with measures of positive and neutral thinking. The measure of paranoia in a recent social situation has good psychometric properties.

  16. A novel experimental technique of nuclear lifetime measurements

    International Nuclear Information System (INIS)

    Yuminov, O.A.; D'Arrigo, A.; Giardina, G.; Taccone, A.; Vannini, G.; Moroni, A.; Ricci, R.A.; Vannucci, L.

    1995-01-01

    In the present paper a new experimental method to measure nuclear reaction time in the 10 -15 -10 -10 s region is presented. Measurements of the lifetimes of low-lying and long-lived states of 19 F and 20 Ne decaying via α-channel were carried out with the aim of checking the feasibility of the method. The results obtained in this way are compared with the lifetimes known from different techniques. ((orig.))

  17. Audiovisual Biofeedback Improves Cine–Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Danny [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sidney, NSW (Australia); Greer, Peter B. [School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, NSW (Australia); Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW (Australia); Ludbrook, Joanna; Arm, Jameen; Hunter, Perry [Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW (Australia); Pollock, Sean; Makhija, Kuldeep; O' brien, Ricky T. [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sidney, NSW (Australia); Kim, Taeho [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sidney, NSW (Australia); Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Keall, Paul, E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sidney, NSW (Australia)

    2016-03-01

    Purpose: To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. Methods and Materials: Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, and the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. Results: Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). Conclusions: These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.

  18. Audiovisual Biofeedback Improves Cine–Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency

    International Nuclear Information System (INIS)

    Lee, Danny; Greer, Peter B.; Ludbrook, Joanna; Arm, Jameen; Hunter, Perry; Pollock, Sean; Makhija, Kuldeep; O'brien, Ricky T.; Kim, Taeho; Keall, Paul

    2016-01-01

    Purpose: To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. Methods and Materials: Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, and the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. Results: Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). Conclusions: These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.

  19. Some observations on precipitation measurement on forested experimental watersheds

    Science.gov (United States)

    Raymond E. Leonard; Kenneth G. Reinhart

    1963-01-01

    Measurement of precipitation on forested experimental watersheds presents difficulties other than those associated with access to and from the gages in all kinds of weather. For instance, the tree canopy must be cleared above the gage. The accepted practice of keeping an unobstructed sky view of 45" around the gage involves considerable tree cutting. On a level...

  20. Electron density measurement in an evolving plasma. Experimental devices

    International Nuclear Information System (INIS)

    Consoli, Terenzio; Dagai, Michel

    1960-01-01

    The experimental devices described here allow the electron density measurements in the 10 16 e/m 3 to 10 20 e/m 3 interval. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 250, p. 1223-1225, sitting of 15 February 1960 [fr

  1. Reconstruction of dynamic structures of experimental setups based on measurable experimental data only

    Science.gov (United States)

    Chen, Tian-Yu; Chen, Yang; Yang, Hu-Jiang; Xiao, Jing-Hua; Hu, Gang

    2018-03-01

    Nowadays, massive amounts of data have been accumulated in various and wide fields, it has become today one of the central issues in interdisciplinary fields to analyze existing data and extract as much useful information as possible from data. It is often that the output data of systems are measurable while dynamic structures producing these data are hidden, and thus studies to reveal system structures by analyzing available data, i.e., reconstructions of systems become one of the most important tasks of information extractions. In the past, most of the works in this respect were based on theoretical analyses and numerical verifications. Direct analyses of experimental data are very rare. In physical science, most of the analyses of experimental setups were based on the first principles of physics laws, i.e., so-called top-down analyses. In this paper, we conducted an experiment of “Boer resonant instrument for forced vibration” (BRIFV) and inferred the dynamic structure of the experimental set purely from the analysis of the measurable experimental data, i.e., by applying the bottom-up strategy. Dynamics of the experimental set is strongly nonlinear and chaotic, and itʼs subjects to inevitable noises. We proposed to use high-order correlation computations to treat nonlinear dynamics; use two-time correlations to treat noise effects. By applying these approaches, we have successfully reconstructed the structure of the experimental setup, and the dynamic system reconstructed with the measured data reproduces good experimental results in a wide range of parameters.

  2. Automated procedure for volumetric measurement of metastases. Estimation of tumor burden

    International Nuclear Information System (INIS)

    Fabel, M.; Bolte, H.

    2008-01-01

    Cancer is a common and increasing disease worldwide. Therapy monitoring in oncologic patient care requires accurate and reliable measurement methods for evaluation of the tumor burden. RECIST (response evaluation criteria in solid tumors) and WHO criteria are still the current standards for therapy response evaluation with inherent disadvantages due to considerable interobserver variation of the manual diameter estimations. Volumetric analysis of e.g. lung, liver and lymph node metastases, promises to be a more accurate, precise and objective method for tumor burden estimation. (orig.) [de

  3. Experimental determination of entanglement with a single measurement.

    Science.gov (United States)

    Walborn, S P; Souto Ribeiro, P H; Davidovich, L; Mintert, F; Buchleitner, A

    2006-04-20

    Nearly all protocols requiring shared quantum information--such as quantum teleportation or key distribution--rely on entanglement between distant parties. However, entanglement is difficult to characterize experimentally. All existing techniques for doing so, including entanglement witnesses or Bell inequalities, disclose the entanglement of some quantum states but fail for other states; therefore, they cannot provide satisfactory results in general. Such methods are fundamentally different from entanglement measures that, by definition, quantify the amount of entanglement in any state. However, these measures suffer from the severe disadvantage that they typically are not directly accessible in laboratory experiments. Here we report a linear optics experiment in which we directly observe a pure-state entanglement measure, namely concurrence. Our measurement set-up includes two copies of a quantum state: these 'twin' states are prepared in the polarization and momentum degrees of freedom of two photons, and concurrence is measured with a single, local measurement on just one of the photons.

  4. Prognostic value of tumor burden measurement using the number of tumors in non-surgical patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Zhang, Hao; Wroblewski, Kristen; Pu, Yonglin

    2012-01-01

    Background: No study to test the feasibility and prognostic value of the number of primary tumors, the number of positive lymph nodes, and the total number of tumors in the whole body as tumor burden measurements on FDG PET/CT imaging has been reported. Purpose: To determine whether the number of tumors seen in 18F-FDG PET scans can be a prognostic factor in non-surgical patients with non-small cell lung cancer (NSCLC). Material and Methods: One hundred and forty patients with histologically proven NSCLC and baseline 18F-FDG PET scan before therapy were identified in this retrospective analysis. The total number of tumors (TTn) in the whole body, the number of primary tumors (Tn), positive lymph nodes (Nn), and distant metastases (Mn), along with the maximum standardized uptake values (SUVmax) of the tumors were measured. Inter-observer variability of the total number of tumors, counted by two radiologists, was assessed. Survival analyses were performed to determine the prognostic value of the number of tumors. Results: Concordance correlation coefficients for the TTn, Tn, Nn, and Mn were all greater than 0.85. TTn and Nn were strong prognostic factors of NSCLC patients' overall survival (OS). In univariate Cox regression models, gender, stage, TTn, Nn, and Mn were statistically significant factors (P = 0.016, 0.032, 4. Conclusion: Measuring the number of tumors on FDG PET imaging is easy to perform with minimal inter-observer variability. The total number of tumors and number of nodal metastases, as metabolic tumor burden measurements in 18F-FDG PET/CT, are prognostic markers independent of clinical stage, age, gender, and SUV measurement in non-surgical patients with NSCLC

  5. Experimental measurement of zero power reactor transfer function

    International Nuclear Information System (INIS)

    Liang Shuhong

    2011-01-01

    In order to study the zero power reactor (ZPR) transfer function, the ZPR transfer function expression was deduced with the point reactor kinetics equation, which was disturbed by reactivity input response. Based on the Fourier analysis for the input of triangular wave, the relation between the transfer function and reactivity was got. Validating research experiment was made on the DF-VI fast ZPR. After the disturbed reactivity was measured, the experimental value of the transfer function was got. According to the experimental value and the calculated value, the expression of the ZPR transfer function is proved, whereas the disturbed reactivity is got from the transfer function. (authors)

  6. Experimental induction of ovarian Sertoli cell tumors in rats by N-nitrosoureas.

    Science.gov (United States)

    Maekawa, A; Onodera, H; Tanigawa, H; Furuta, K; Kanno, J; Ogiu, T; Hayashi, Y

    1987-01-01

    Spontaneous ovarian tumors are very rare in ACI, Wistar, F344 and Donryu rats; the few neoplasms found are of the granulosa/theca cell type. Ovarian tumors were also rare in these strains of rats when given high doses of N-alkyl-N-nitrosoureas continuously in the drinking water for their life-span; however, relatively high incidences of Sertoli cell tumors or Sertoli cell tumors mixed with granulosa cell tumors were induced in Donryu rats after administration of either a 400 ppm N-ethyl-N-nitrosourea solution in the drinking water for 4 weeks or as a single dose of 200 mg N-propyl-N-nitrosourea per kg body weight by stomach tube. Typical Sertoli cell tumors consisted of solid areas showing tubular formation. The tubules were lined by tall, columnar cells, with abundant, faintly eosinophilic, often vacuolated cytoplasm, and basally oriented, round nuclei, resembling seminiferous tubules in the testes. In some cases, Sertoli cell tumor elements were found mixed with areas of granulosa cells. The induction of ovarian Sertoli cell tumors in Donryu rats by low doses of nitrosoureas may provide a useful model for these tumors in man. Images PLATE 1. PLATE 2. PLATE 3. PLATE 4. PLATE 5. PLATE 6. PLATE 7. PLATE 8. PLATE 9. PLATE 10. PLATE 11. PLATE 12. PLATE 13. PLATE 14. PLATE 15. PLATE 16. PMID:3665856

  7. Experimental Method for Measuring Dust Load on Surfaces in Rooms

    DEFF Research Database (Denmark)

    Lengweiler, Philip; Nielsen, Peter V.; Moser, Alfred

    A new experimental setup to investigate the physical process of dust deposition and resuspension on and from surfaces is introduced. Dust deposition can reduce the airborne dust concentration considerably. As a basis for developing methods to eliminate dust-related problems in rooms, there is a n......A new experimental setup to investigate the physical process of dust deposition and resuspension on and from surfaces is introduced. Dust deposition can reduce the airborne dust concentration considerably. As a basis for developing methods to eliminate dust-related problems in rooms......, there is a need for better understanding of the mechanism of dust deposition and resuspension. With the presented experimental setup, the dust load on surfaces in a channel can be measured as a function of the environmental and surface conditions and the type of particles under controlled laboratory conditions....

  8. [Experimental tumors of the central nervous system: standardisation of a model in rats using the 9L glioma cells].

    Science.gov (United States)

    Michailowsky, Custódio; Niura, Flavio Key; do Valle, Angela C; Sonohara, Shigueko; Meneguin, Thales D'Alessandro; Tsanaclis, Ana Maria C

    2003-06-01

    A number of experimental models have been established during the last decades in order to study tumor biology and the effects of treatment or manipulation of the microenvironment of malignant glial tumors. Even though those models have been well characterised and are, to a certain extent, easily reproducible, there are limitations as to their use and to the interpretation of the results. The aim of this study is to standardize a model of a malignant glial tumor and detect possible events able to modify its development. 9L cells were inoculated intracerebrally in 48 Sprague-Dawley rats; from these, 25 animals were also implanted with a device containing electrodes for the registration of the electroencephalogramm. Animals were daily evaluated by neurologic examination. Twenty four animals developed tumor - 10 animals died either in the immediate pos-operatory period or during evolution; 14 animals did not develop tumor. Macroscopically the tumor was well demarcated from the adjacent brain; by light microscopy the tumor exhibited malignant characteristics as well as extensive infiltration of the brain parenchyma. Diagnosis was that of a malignant astrocytoma. The use of the stereotaxic frame and care to infuse a small volume of liquid containing cells during a period of 120 seconds were the most important procedures to obtain sucess in the model. Additional care should be taken in counting cells in the Neubauer camera and in maintaining cells in constant agitation before injecting the tumor-containing solution. The model here developed was efficient besides being of low cost and of relatively easy execution.

  9. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  10. Radiosensitizing effect of nitric oxide in tumor cells and experimental tumors irradiated with gamma rays and proton beams; Efecto radiosensibilizador del oxido nitrico en celulas tumorales y en tumores experimentales irradiados con radiacion gamma y con haces de protones

    Energy Technology Data Exchange (ETDEWEB)

    Policastro, Lucia L; Duran, Hebe; Molinari, Beatriz L [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia; Schuff, Juan A; Kreiner, Andres J; Burlon, Alejandro A; Debray, Mario E; Kesque, Jose M; Ozafran, Mabel J; Vazquez, Monica E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Fisica; Davidson, Jorge; Davidson, Miguel [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina); Somacal, Hector R; Valda, Alejandro A [Universidad Nacional de General San Martin , Villa Ballester (Argentina). Escuela de Ciencia y Tecnologia

    2003-07-01

    Nitric oxide (NO) has been reported to be a radiosensitizer of mammalian cells under hypoxic conditions. In a previous study, we demonstrated an enhancement in radiation response induced by NO in mouse tumor cells under aerobic conditions, with an increasing effect as a function of malignancy. The aim of the present study was to evaluate the effect of NO in tumor cells and in experimental tumors irradiated with {gamma} rays and proton beams. Irradiations were performed with a {sup 137}Cs {gamma} source and with proton beams generated by the TANDAR accelerator. Tumor cells were treated with the NO donor DETA-NO and the sensitizer enhancement ratio (SER) was calculated using the {alpha} parameter of the survival curve fitted to the linear-quadratic model. Tumor cells irradiated with protons were radio sensitized by DETA-NO only in the more malignant cells irradiated with low LET protons (2.69{+-}0.08 keV/{mu}m). For higher LET protons there were no radiosensitizing effect. For human tumor cells pre-treated with DETA-NO and irradiated with {gamma} rays, a significantly greater effect was demonstrated in the malignant cells (MCF-7) as compared with the near normal cells (HBL-100). Moreover, a significant decrease in tumor growth was demonstrated in mice pre-treated with the NO donor spermine and irradiated with {gamma} rays and low LET protons as compared with mice irradiated without pre-treatment with the NO donor. In conclusion, we demonstrated a differential effect of NO as a radiosensitizer of malignant cells, both with {gamma} rays and low LET protons. This selectivity, coupled to the in vivo inhibition of tumor growth, is of great interest for the potential use of NO releasing agents in radiotherapy. (author)

  11. Experimental study on anti-tumor effect of pcEgr-IFNγ gene-radiotherapy

    International Nuclear Information System (INIS)

    Wu Congmei; Li Xiuyi; Liu Shuzheng

    2001-01-01

    Objective: To study the anti-tumor effect of IFN γ gene-radiotherapy to murine melanoma and its immunologic mechanism. Methods: pcEgr-IFNγ plasmids were injected locally into tumor, and 36 hours later, the tumors were given 20 Gy X-ray irradiation. Tumor growth at different time, IFN γ expression 3 days later and immunologic indexes 15 days later were detected. Results: At 3-15 days after pcEgr-IFNγ gene-radiotherapy, the tumor growth rate was lower than that of irradiation alone group. It was also lower than that of gene therapy alone group and control plasmid combined with X-ray irradiation group significantly. Day 3 tumor IFN γ expression was higher than that of plasmid treatment alone group. NK activity, IL-2 and IFN γ secretion activities were higher than those of gene therapy alone and irradiation alone groups significantly. Conclusion: The antitumor effect of IFN γ gene-radiotherapy is better than that of either of them applied solely. Its mechanism might be concerned with the higher expression of IFN γ induced by irradiation in tumors and activation of anti-tumor immunologic functions

  12. Effect of x irradiation on the vascularization of experimental animal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, Y; Ogawa, F; Nishiguchi, H; Tanaka, N; Murakami, K [Kyoto Prefectural Univ. of Medicine (Japan)

    1975-03-01

    The authors studied the effect of ionizing radiation on blood vessels and tumor growth in two animal tumor systems: a third generation isoplants of a mammary cancer and a spontaneously arising squamous cell carcinoma. Single cell suspensions were transplanted into a C3H and a C3Hf mouse respectively. They were irradiated once with 2000 rad when the tumors reached about 8 mm in diameter. Microangiography was performed at a constant temperature and pressure, and a contrast medium containing lead-oxide and gelatin was flushed the vena cava for 10 min. at 120 mmHg. Tumor shrinkage was followed by continuous regrowth. The basic vasculature of the mammary carcinoma consisted of abundant large and fine blood vessels corkscrewed or stretched from the periphery of the tumor to its center in complex reticular networks. One day after irradiation there were small scattered avascular areas which, by the third day formed a large central necrosis. Supervascularization was also observed, indicating that some hypoxic tumor cells could be reoxygenized. In 5 days vascularization was similar to that of a nonirradiated tumor. Conversely, The squamous cell carcinoma showed peripheral and central vascularization with abundant vascular and avascular areas and extravasion in the large avascular area. Two days after irradiation the vessels were dilated. At 3 days peripheral fine vessels were damaged but the central vasculature remained intact. Unlike the mammary carcinoma, supervascularization was not the typical finding. At 5 days, vascularization was similar to that of a nonirradiated tumor.

  13. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  14. Combined calcitriol and menadione reduces experimental murine triple negative breast tumor.

    Science.gov (United States)

    Bohl, Luciana; Guizzardi, Solange; Rodríguez, Valeria; Hinrichsen, Lucila; Rozados, Viviana; Cremonezzi, David; Tolosa de Talamoni, Nori; Picotto, Gabriela

    2017-10-01

    Calcitriol (D) or 1,25(OH) 2 D 3 inhibits the growth of several tumor cells including breast cancer cells, by activating cell death pathways. Menadione (MEN), a glutathione-depleting compound, may be used to potentiate the antiproliferative actions of D on cancer cells. We have previously shown in vitro that MEN improved D-induced growth arrest on breast cancer cell lines, inducing oxidative stress and DNA damage via ROS generation. Treatment with MEN+D resulted more effective than D or MEN alone. To study the in vivo effect of calcitriol, MEN or their combination on the development of murine transplantable triple negative breast tumor M-406 in its syngeneic host. Tumor M-406 was inoculated s.c., and when tumors reached the desired size, animals were randomly assigned to one of four groups receiving daily i.p. injections of either sterile saline solution (controls, C), MEN, D, or both (MEN+D). Body weight and tumor volume were recorded three times a week. Serum calcium was determined before and at the end of the treatment, at which time tumor samples were obtained for histological examination. None of the drugs, alone or in combination, affected mice body weight in the period studied. The combined treatment reduced tumor growth rate (C vs. MEN+D, P<0.05) and the corresponding histological sections exhibited small remaining areas of viable tumor only in the periphery. A concomitant DNA fragmentation was observed in all treated groups and MEN potentiated the calcitriol effect on tumor growth. As previously observed in vitro, treatment with MEN and D delayed tumor growth in vivo more efficiently than the individual drugs, with evident signals of apoptosis induction. Our results propose an alternative protocol to treat triple negative breast cancer, using GSH depleting drugs together with calcitriol, which would allow lower doses of the steroid to maintain the antitumor effect while diminishing its adverse pharmacological effects. Copyright © 2017. Published by

  15. Contact Angle Measurements Using a Simplified Experimental Setup

    Science.gov (United States)

    Lamour, Guillaume; Hamraoui, Ahmed; Buvailo, Andrii; Xing, Yangjun; Keuleyan, Sean; Prakash, Vivek; Eftekhari-Bafrooei, Ali; Borguet, Eric

    2010-01-01

    A basic and affordable experimental apparatus is described that measures the static contact angle of a liquid drop in contact with a solid. The image of the drop is made with a simple digital camera by taking a picture that is magnified by an optical lens. The profile of the drop is then processed with ImageJ free software. The ImageJ contact…

  16. Experimental assessment of the role of the blood flow inhibition in hyperglycemia-enhanced radiation injury to tumor

    International Nuclear Information System (INIS)

    Kozin, S.V.; Sevast'yanov, A.I.; Yarmonenko, S.P.

    1986-01-01

    Experimental assessment of the role of the blood flow inhibition in enhancement of radiation injury to tumors using short-term hyperglycemia was provided. Experiments on mice with Ehrlich solid carcinoma showed the dependence of a rise of the antitumor effect of preceding radiation induced by glucose and glucose combined with mexamin on a degree of the blood flow inhibition under the influence of these modifying agents. It was established that a considerable enhancement of radiation injury occured but in such tumors where short-term hyperglycemia and mexamin decreased the blood flow level not less than 5-10 fold as estimated by 133 Xe clearance. The results of the above experiments showed that the noticeable inhibition of the blood flow in tumors was a necessary tough, probably, not the only condition for a high efficacy of short-term hyperglycemia used an ajuvant to radiotherapy

  17. submitter Experimental temperature measurements for the energy amplifier test

    CERN Document Server

    Calero, J; Gallego, E; Gálvez, J; García Tabares, L; González, E; Jaren, J; López, C; Lorente, A; Martínez Val, J M; Oropesa, J; Rubbia, C; Rubio, J A; Saldana, F; Tamarit, J; Vieira, S

    1996-01-01

    A uranium thermometer has been designed and built in order to make local power measurements in the First Energy Amplifier Test (FEAT). Due to the experimental conditions power measurements of tens to hundreds of nW were required, implying a sensitivity in the temperature change measurements of the order of 1 mK. A uranium thermometer accurate enough to match that sensitivity has been built. The thermometer is able to determine the absolute energetic gain obtained in a tiny subcritical uranium assembly exposed to a proton beam of kinetic energies between 600 MeV and 2.75 GeV. In addition, the thermometer measurements have provided information about the spatial power distribution and the shape of the neutron spallation cascade.

  18. White Adipose Tissue Cells Are Recruited by Experimental Tumors and Promote Cancer Progression in Mouse Models

    Science.gov (United States)

    Zhang, Yan; Daquinag, Alexes; Traktuev, Dmitry O.; Amaya-Manzanares, Felipe; Simmons, Paul J.; March, Keith L.; Pasqualini, Renata; Arap, Wadih; Kolonin, Mikhail G.

    2010-01-01

    The connection between obesity and accelerated cancer progression has been established, but the mediating mechanisms are not well understood. We have shown that stromal cells from white adipose tissue (WAT) cooperate with the endothelium to promote blood vessel formation through the secretion of soluble trophic factors. Here, we hypothesize that WAT directly mediates cancer progression by serving as a source of cells that migrate to tumors and promote neovascularization. To test this hypothesis, we have evaluated the recruitment of WAT-derived cells by tumors and the effect of their engraftment on tumor growth by integrating a transgenic mouse strain engineered for expansion of traceable cells with established allograft and xenograft cancer models. Our studies show that entry of adipose stromal and endothelial cells into systemic circulation leads to their homing to and engraftment into tumor stroma and vasculature, respectively. We show that recruitment of adipose stromal cells by tumors is sufficient to promote tumor growth. Finally, we show that migration of stromal and vascular progenitor cells from WAT grafts to tumors is also associated with acceleration of cancer progression. These results provide a biological insight for the clinical association between obesity and cancer, thus outlining potential avenues for preventive and therapeutic strategies. PMID:19491274

  19. The experimental study on liver VX-2 tumor by using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Yuan Youhong; Xiao Enhua; Jin Ke; Yan Ronghua; He Zhong; Shang Quanliang; Hu Weizhou; Yuan Shiwen; Xiang Jun; Tang Keli; Yi Shijian; Yin Qiang

    2005-01-01

    Objective: To study the imaging characteristics of rabbit's liver VX-2 tumor on MR diffusion-weighted imaging. Methods: Of the 35 New Zealand rabbits, 14 were implanted under the skin while 6 were implanted in liver with VX-2 tumor in preparing experiment, and 12 were implanted in liver and 3 as controls in formal experiment. Before and after the implantation, MR diffusion-weighted imaging (DWI), T 1 -weighted and T 2 -weighted images were performed respectively and periodically in 15 tumors including 12 liver tumor implantations in formal experiment. DWI parameters including apparent diffusion coefficient (ADC) value were acquired and statistically analyzed by SPSS 10.0. Results: (1) The successful rate of implantation was 29% (4/14) under the skin and 33% (2/6) in the liver in preparing experiment. And the successful rate of formal experiment was 83% (10/12). (2) DWI signal of VX-2 tumor was high and the signal became lower and lower with b value increased step by step. The signal of VX-2 tumor on ADC map was low. The ADC value of normal group was (2.57 ± 0.26) mm 2 /s (b=100 s/mm 2 ) and (1.73 ± 0.31) mm 2 /s (b=300 s/mm 2 ), and ADC value of VX-2 tumor group was (1.87 ± 0.25) mm 2 /s (b=100 s/mm 2 ) and (1.57 ± 0.23) mm 2 /s (b=300 s/mm 2 ), respectively.The F value of analysis of variance was 43.26 (P<0.001). The distinction of tumor ADC value in different b values was significant (P<0.05), and the distinction of ADC value between VX-2 tumor and normal liver was also significant (P<0.01). (3) VX-2 tumor developed quickly and metastasized early to all parts of the body, especially to the lung, the liver, the lymph nodes of mediastinum and so on. Conclusion: DWI signal of VX-2 tumor has its characteristic and DWI has important value in reflecting the movement of water molecules, discovering the VX-2 tumor, and tracking its progress. (authors)

  20. In Vivo Imaging of Experimental Melanoma Tumors using the Novel Radiotracer 68Ga-NODAGA-Procainamide (PCA).

    Science.gov (United States)

    Kertész, István; Vida, András; Nagy, Gábor; Emri, Miklós; Farkas, Antal; Kis, Adrienn; Angyal, János; Dénes, Noémi; Szabó, Judit P; Kovács, Tünde; Bai, Péter; Trencsényi, György

    2017-01-01

    The most aggressive form of skin cancer is the malignant melanoma. Because of its high metastatic potential the early detection of primary melanoma tumors and metastases using non-invasive PET imaging determines the outcome of the disease. Previous studies have already shown that benzamide derivatives, such as procainamide (PCA) specifically bind to melanin pigment. The aim of this study was to synthesize and investigate the melanin specificity of the novel 68 Ga-labeled NODAGA-PCA molecule in vitro and in vivo using PET techniques. Procainamide (PCA) was conjugated with NODAGA chelator and was labeled with Ga-68 ( 68 Ga-NODAGA-PCA). The melanin specificity of 68 Ga-NODAGA-PCA was tested in vitro , ex vivo and in vivo using melanotic B16-F10 and amelanotic Melur melanoma cell lines. By subcutaneous and intravenous injection of melanoma cells tumor-bearing mice were prepared, on which biodistribution studies and small animal PET/CT scans were performed for 68 Ga-NODAGA-PCA and 18 FDG tracers. 68 Ga-NODAGA-PCA was produced with high specific activity (14.9±3.9 GBq/µmol) and with excellent radiochemical purity (98%PCA uptake of B16-F10 cells was significantly ( p ≤0.01) higher than Melur cells. Ex vivo biodistribution and in vivo PET/CT studies using subcutaneous and metastatic tumor models showed significantly ( p ≤0.01) higher 68 Ga-NODAGA-PCA uptake in B16-F10 primary tumors and lung metastases in comparison with amelanotic Melur tumors. In experiments where 18 FDG and 68 Ga-NODAGA-PCA uptake of B16-F10 tumors was compared, we found that the tumor-to-muscle (T/M) and tumor-to-lung (T/L) ratios were significantly ( p ≤0.05 and p ≤0.01) higher using 68 Ga-NODAGA-PCA than the 18 FDG accumulation. Our novel radiotracer 68 Ga-NODAGA-PCA showed specific binding to the melanin producing experimental melanoma tumors. Therefore, 68 Ga-NODAGA-PCA is a suitable diagnostic radiotracer for the detection of melanoma tumors and metastases in vivo .

  1. Effect of carbogen on tumor oxygenation: combined fluorine-19 and proton MRI measurements

    International Nuclear Information System (INIS)

    Fan Xiaobing; River, Jonathan N.; Zamora, Marta; Al-Hallaq, Hania A.; Karczmar, Gregory S.

    2002-01-01

    Purpose: Blood oxygen level dependent (BOLD) contrast in magnetic resonance imaging (MRI) has been widely used for noninvasive evaluation of the effects of tumor-oxygenating agents. However, there have been few tests of the validity of this method. The goal of the present work was to use the T 1 of fluorine-19 in perfluorocarbon (PFC) emulsions as a 'gold standard' for comparison with BOLD MRI. Methods and Materials: Rats bearing R3230AC tumors implanted in the hind limb were injected with an emulsion of perfluoro-15-crown-5-ether for 2-3 days before experiments, which ensured that the PFC emulsion concentrated in the tumors. We correlated changes in tumor oxygenation caused by carbogen inhalation measured by 1 H BOLD MRI with quantitative 19 F measurements. The 19 F spin-lattice relaxation rate R 1 (= 1/T 1 ) was measured to determine initial oxygen tension (pO 2 ) in each image pixel containing the PFC, and changes in pO 2 during carbogen (95% O 2 , 5% CO 2 ) breathing. In a second carbogen breathing period, changes in water signal linewidth were measured using high spectral and spatial resolution imaging. 19 F and 1 H measurements were used to classify pixels as responders to carbogen (pixels where oxygen increased significantly) or nonresponders (no significant change in tumor oxygenation). Results: The 19 F and 1 H measurements agreed in 65% ± 11% of pixels (n = 14). Agreement was even stronger among pixels where 1 H showed increased oxygenation; 19 F measurements agreed with 1 H measurements in over 79% ± 11% of these pixels. Similarly, there was strong agreement between the two modalities in pixels where 19 F reported no change in pO 2 ; 1 H also showed no changes in 76% ± 18% of these pixels. Quantitative correlation of changes T 2 * (ΔT 2 *) in 1 H and changes R 1 (ΔR 1 ) in 19 F was weak during carbogen breathing, and averaged over the whole tumor was ∼0.40 for 14 experiments. However, the spatial patterns of 1 H and 19 F changes were qualitatively

  2. Experimental measurements of the cavitating flow after horizontal water entry

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thang Tat; Thai, Nguyen Quang; Phuong, Truong Thi [Institute of Mechanics (IMECH), Vietnam Academy of Science and Technology (VAST), 264—Doi Can, Ba Dinh, Hanoi (Viet Nam); Hai, Duong Ngoc, E-mail: ntthang@imech.vast.vn, E-mail: dnhai@vast.vn, E-mail: nqthai@imech.vast.vn, E-mail: ttphuong@imech.vast.vn [Graduate University of Science and Technology (GUST), VAST, 18—Hoang Quoc Viet, Cau Giay, Hanoi (Viet Nam)

    2017-10-15

    Water-entry cavitating flow is of considerable importance in underwater high-speed applications. That is because of the drag-reduction effect that concerns the presence of a cavity around moving objects. Though the study of the flow has long been carried out, little data are documented in literature so far. Besides, currently, in the case of unsteady flow, experimental measurements of some flow parameters such as the cavity pressure still encounter difficulties. Hence continuing research efforts are of important significance. The objective of this study is to investigate experimentally the unsteady cavitating flow after the horizontal water entry of projectiles. An experimental apparatus has been developed. Qualitative and quantitative optical visualizations of the flow have been carried out by using high-speed videography. Digital image processing has been applied to analyzing the recorded flow images. Based on the known correlations between the ellipsoidal super-cavity’s size and the corresponding cavitation number, the cavity pressure has been measured by utilizing the data of image processing. A comparison between the partial- and super-cavitating flow regimes is reported. The received results can be useful for the design of high-speed underwater projectiles. (paper)

  3. The behavior of the vascular system in the experimental tumor radiotherapy

    International Nuclear Information System (INIS)

    Yamaura, Hirotsugu; Matsuzawa, Taiju; Sato, Haruo; Ito, Yasuhiko.

    1975-01-01

    The rat ascites hepatoma AH109A transplanted and grown in the rat transparent chamber developed a tumor specific vascular system, the process of which was quantitatively studied because of the vascular length, surface area, and volume per mm 3 of tissue. The values changed characteristically in each stage of the course. The tumor was irradiated in a chamber with 3000 R of 60 Co γ-rays, and the tumor cells died leaving behind highly dense capillary networks, which gradually returned to normal level by 7 days after irradiation. The blood vessels, either preformed or newly formed, in the control tissue without tumor were not damaged by this dose. But the proliferation of capillary buds were inhibited slightly with 400 R and completely with 4000 R. (auth.)

  4. The behavior of the vascular system in the experimental tumor radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaura, H; Matsuzawa, T; Sato, H [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis, Leprosy and Cancer; Ito, Yasuhiko

    1975-07-01

    The rat ascites hepatoma AH109A transplanted and grown in the rat transparent chamber developed a tumor specific vascular system, the process of which was quantitatively studied because of the vascular length, surface area, and volume per mm/sup 3/ of tissue. The values changed characteristically in each stage of the course. The tumor was irradiated in a chamber with 3000 R of /sup 60/Co ..gamma..-rays, and the tumor cells died leaving behind highly dense capillary networks, which gradually returned to normal level by 7 days after irradiation. The blood vessels, either preformed or newly formed, in the control tissue without tumor were not damaged by this dose. But the proliferation of capillary buds were inhibited slightly with 400 R and completely with 4000 R.

  5. Using Positron Emission Tomography with [18F]FDG to Predict Tumor Behavior in Experimental Colorectal Cancer

    Directory of Open Access Journals (Sweden)

    Bryan M. Burt

    2001-01-01

    Full Text Available This study investigates the relationship between FDG uptake as determined by positron emission tomography (PET imaging and rates of tumor growth, cellular GLUT1 transporter density, and the activities of hexokinase and glucose-6-phosphatase in a solid tumor implant model. Five different human colorectal xenografts of different growth properties were implanted in athymic rats and evaluated by dynamic 18F-FDG-PET. The phosphorylating and dephosphorylating activities of the key glycolytic enzymes, hexokinase and glucose-6-phosphatase, were measured in these tumor types by spectrophotometric assays and the expression of GLUT1 glucose transporter protein was determined by immunohistochemistry. Correlations among FDG accumulation, hexokinase activity, and tumor doubling time are reported in these colon xenografts. The results indicate that the activity of tumor hexokinase may be a marker of tumor growth rate that can be determined by 18F-FDG-PET imaging. PET scanning may not only be a useful tool for staging patients for extent of disease, but may provide important prognostic information concerning the proliferative rates of malignancies.

  6. Quantification of tomographic PIV uncertainty using controlled experimental measurements.

    Science.gov (United States)

    Liu, Ning; Wu, Yue; Ma, Lin

    2018-01-20

    The goal of this work was to experimentally quantify the uncertainty of three-dimensional (3D) and three-component (3C) velocity measurements using tomographic particle image velocimetry (tomo-PIV). Controlled measurements were designed using tracer particles embedded in a solid sample, and tomo-PIV measurements were performed on the sample while it was moved both translationally and rotationally to simulate various known displacement fields, so the 3D3C displacements measured by tomo-PIV can be directly compared to the known displacements created by the sample. The results illustrated that (1) the tomo-PIV technique was able to reconstruct the 3D3C velocity with an averaged error of 0.8-1.4 voxels in terms of magnitude and 1.7°-1.9° in terms of orientation for the velocity fields tested; (2) view registration (VR) plays a significant role in tomo-PIV, and by reducing VR error from 0.6° to 0.1°, the 3D3C measurement accuracy can be improved by at least 2.5 times in terms of both magnitude and orientation; and (3) the use of additional cameras in tomo-PIV can extend the 3D3C velocity measurement to a larger volume, while maintaining acceptable accuracy. These results obtained from controlled tests are expected to aid the error analysis and the design of tomo-PIV measurements.

  7. Transcription factor Runx2 knockdown regulates colon cancer transplantation tumor growth in vitro: an experimental study

    Directory of Open Access Journals (Sweden)

    Bin Xu1

    2017-05-01

    Full Text Available Objective: To study the effect of transcription factor Runx2 knockdown on colon cancer transplantation tumor growth in vitro. Methods: Colon cancer cell lines HT29 were cultured and transfected with negative control (NC - shRNA plasmids and Runx2-shRNA plasmids respectively, the colon cancer cells transfected with shRNA were subcutaneously injected into C57 nude mice, and they were included in NC group and Runx2 knockdown group respectively. 1 week, 2 weeks and 3 weeks after model establishment, serum was collected to determine the contents of tumor markers, and tumor lesions were collected to determine proliferation and apoptosis gene expression. Results: CCSA-2, CEA and CA19-9 levels in serum as well as Rac1, Wnt3a, PLD2 and FAM96B protein expression in transplantation tumor lesions of Runx2 knockdown group were significantly lower than those of NC group while MS4A12, ASPP2 and Fas protein expression in transplantation tumor lesions of Runx2 knockdown group were significantly higher than those of NC group. Conclusion: Transcription factor Runx2 knockdown could inhibit the colon cancer transplantation tumor growth in vitro.

  8. Experimental solubility measurements of lanthanides in liquid alkalis

    Science.gov (United States)

    Isler, Jeremy; Zhang, Jinsuo; Mariani, Robert; Unal, Cetin

    2017-11-01

    In metallic nuclear fuel, lanthanide fission products play a crucial role in the fuel burnup-limiting phenomena of fuel cladding-chemical interaction (FCCI). The lanthanides have been hypothesized to transport by a 'liquid-like' mechanism out of the metallic fuel to the fuel peripheral to cause FCCI. By liquid fission product cesium and liquid bond sodium, the lanthanides are transported to the peripheral of the fuel through the porosity of the fuel. This work investigates the interaction between the lanthanides and the alkali metals by experimentally measuring the solubility of lanthanides within liquid sodium, and neodymium in liquid cesium and mixtures of cesium and sodium. The temperature dependence of the solubility is experimentally determined within an inert environment. In addition, the dependence of the solubility on the alkali metal concentration in liquid mixtures of cesium and sodium was examined. In quantifying the solubility, the fundamental understanding of this transport mechanism can be better determined.

  9. 3D tumor measurement in cone-beam CT breast imaging

    Science.gov (United States)

    Chen, Zikuan; Ning, Ruola

    2004-05-01

    Cone-beam CT breast imaging provides a digital volume representation of a breast. With a digital breast volume, the immediate task is to extract the breast tissue information, especially for suspicious tumors, preferably in an automatic manner or with minimal user interaction. This paper reports a program for three-dimensional breast tissue analysis. It consists of volumetric segmentation (by globally thresholding), subsegmentation (connection-based separation), and volumetric component measurement (volume, surface, shape, and other geometrical specifications). A combination scheme of multi-thresholding and binary volume morphology is proposed to fast determine the surface gradients, which may be interpreted as the surface evolution (outward growth or inward shrinkage) for a tumor volume. This scheme is also used to optimize the volumetric segmentation. With a binary volume, we decompose the foreground into components according to spatial connectedness. Since this decomposition procedure is performed after volumetric segmentation, it is called subsegmentation. The subsegmentation brings the convenience for component visualization and measurement, in the whole support space, without interference from others. Upon the tumor component identification, we measure the following specifications: volume, surface area, roundness, elongation, aspect, star-shapedness, and location (centroid). A 3D morphological operation is used to extract the cluster shell and, by delineating the corresponding volume from the grayscale volume, to measure the shell stiffness. This 3D tissue measurement is demonstrated with a tumor-borne breast specimen (a surgical part).

  10. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  11. First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors

    International Nuclear Information System (INIS)

    Jarm, T.; Miklavcic, D.; Lesnicar, H.; Sersa, G.

    2001-01-01

    Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO 2 ) in tumors and for the detection of changes in pO 2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials and methods. Blood perfusion and pO 2 were measured continuously via fiber-optic sensors inserted into SA-1 tumors in anesthetized A/J mice. The changes in blood flow and oxygenation of tumors were induced by transient changes of the parameters of anesthesia and by injection of a vasoactive drug hydralazine. Results. Both optical methods used in the study successfully detected the induced changes in blood flow and pO 2 . The measurements of pO 2 were well correlated with measurements of microcirculatory blood perfusion. In the majority of pO 2 measurements, we observed an unexpected behavior of the signal during the stabilization process immediately after the insertion of the probe into tumor. This behaviour of the pO 2 signal was most probably caused by local tissue damage induced by the insertion of the probe. Conclusion. The novel luminescence-based optical oximetry can reliably detect local pO 2 changes in tumors as a function of time but some aspects of prolonged pO 2 measurement by this method require further investigation. (author)

  12. Experimental infrared measurements for hydrocarbon pollutant determination in subterranean waters

    Science.gov (United States)

    Lay-Ekuakille, A.; Palamara, I.; Caratelli, D.; Morabito, F. C.

    2013-01-01

    Subterranean waters are often polluted by industrial and anthropic effluents that are drained in subsoil. To prevent and control pollution, legislations of different developed countries require an online monitoring measurement, especially for detecting organic solvents (chlorinated and unchlorinated ones). Online measurements include both real-time and no real-time measurements. In general, it is difficult to implement real-time measurements in stricto sensu for online acquisitions on aqueous effluents since they need to be processed by a modeling. This research presents an experimental measurement system based on infrared (IR) spectroscopy for aqueous effluents containing hydrocarbons and capable of displaying excellent values of pollutant concentrations even in instable conditions; the system is able to detect pollutants either in laminar or turbulent flow. The results show the possibility of avoiding the use of "Pitot tube" that is employed to create a stagnation point in order to convert kinetic energy into potential one. This conversion allows the transformation of a turbulent flow in a laminar flow making easy measurement of pollutants included in an aqueous effluent. Obviously, "Pitot tube" is also used for other fluid effluents. The obtained results have been compared with those produced by means of sophisticated IR instrumentation for laboratory applications.

  13. Measuring Response to Therapy by Near-Infrared Imaging of Tumors Using a Phosphatidylserine-Targeting Antibody Fragment

    Directory of Open Access Journals (Sweden)

    Jian Gong

    2013-06-01

    Full Text Available Imaging tumors and their response to treatment could be a valuable biomarker toward early assessment of therapy in patients with cancer. Phosphatidylserine (PS is confined to the inner leaflet of the plasma membrane in normal cells but is externalized on tumor vascular endothelial cells (ECs and tumor cells, and PS exposure is further enhanced in response to radiation and chemotherapy. In the present study, we evaluated the potential of a PS-targeting human F(ab'2 antibody fragment, PGN650, to detect exposure of PS in tumor-bearing mice. Tumor uptake of PGN650 was measured by near-infrared optical imaging in human tumor xenografts in immunodeficient mice. PGN650 specifically targeted tumors and was shown to target CD31-positive ECs and tumor cells. Tumor uptake of PGN650 was significantly higher in animals pretreated with docetaxel. The peak tumor to normal tissue (T/N ratio of probe was observed at 24 hours postinjection of probe, and tumor binding was detected for at least 120 hours. In repeat dose studies, PGN650 uptake in tumors was significantly higher following pretreatment with docetaxel compared to baseline uptake prior to treatment. PGN650 may be a useful probe to detect PS exposed in tumors and to monitor enhanced PS exposure to optimize therapeutic agents to treat tumors.

  14. Effect of interventional treatment with p53 on the invasion and metastasis of VX2 liver tumor in experimental rabbits

    International Nuclear Information System (INIS)

    Li Caixia; Feng Yan; Gu Tao; Li Chunmei

    2010-01-01

    Objective: To investigate the effect of interventional treatment with p53 on the invasion and metastasis of VX2 liver tumor in experimental rabbits. Methods: VX2 carcinoma cells were surgically implanted into the left hepatic lobe in 48 New Zealand white rabbits, and the rabbit hepatic carcinoma models were thus established. The rabbits were randomly divided into 4 groups with 12 rabbits in each group. After hepatic arterial catheterization was completed physiological saline (control group), Lipiodol (Group A), Ad-p53 (Group B) and Lipiodol+Ad-p53 (Group C) were respectively infused into the rabbits of four groups via common hepatic artery. One week after the procedure the rabbits were sacrificed and the livers were removed for the determination of matrix metalloprotein-2 (MMP-2), proliferating cell nuclear antigen (PCNA) and vascular endothelial growth factor (VEGF) of the tumor with immunohistochemistry technique. Results: The tumor growth in study groups (group A, B and C) was markedly suppressed, which was significantly different in comparison with that in control group (P 0.05). The positive rates of MMP-2, PCNA and VEGF in group B and C were significantly lower than those in control group (P < 0.05). The positive rates of MMP-2, PCNA and VEGF of the rabbits with metastasis were markedly higher than those without metastasis(P < 0.05). MMP-2 bore a certain relationship with VEGF and PCNA (P < 0.05). Conclusion: The increase of the positive rates of MMP-2, PCNA and VEGF indicates that the tumor possesses higher possibility for developing metastasis, proliferation and vascular formation. The interventional treatment with Adp53 or Lipiodol+Ad-p53 can inhibit the growth, metastasis and vascular formation of VX2 liver tumor in experimental rabbits. (J Intervent Radiol, 2010, 19 : 800-804) (authors)

  15. A comparative study of 99mTc-HL91 and 99mTc-MIBI imaging in experimental tumor and inflammatory models

    International Nuclear Information System (INIS)

    Cao, W.; Zhang, X.Y.; An, R.

    2002-01-01

    Aim: 99m Tc-HL91 is a newly developed hypoxic imaging agent for ischemic myocardium and tumor imaging. 99m Tc-MIBI is one of imaging agent for mammary tumor imaging. The aim of this experiment is to evaluate the diagnostic value of 99m Tc-HL91 in detection of solid tumor in experimental tumor and inflammatory models, via comparative study with 99m Tc-MIBI. Material and Methods: HL91 kits was provided by China Nine Star Co. Three kinds of bearing solid neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice and bearing human ovarian COC 1 neoplasm nude mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static whole body planar images at 1 and 4 hours post injection of 99m Tc-HL91. Two kinds of bearing neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static planar images post injection of 99m Tc-MIBI, at early phase (10∼20 minutes) and delayed phase (2 hrs). All of mice were sacrificed at 4 hrs. The tumors, or inflammatory lesions, blood and contralateral muscles were removed, weighed and the radioactivity was measured. Regions of interesting (ROIs) were drawn around tumor, inflammatory lesions and contralateral muscles in planar images, and the radioactivity ratios of target (tumor or inflammatory lesions)-to-blood (T/B), target-to-non target (contralateral muscles) i. e. T/NT was calculated. Results: Neoplasm can be clearly visible in planar images at 1hr and 4 hrs post injection of 99m Tc-HL91 in all tumor models. At same time inflammatory lesions cannot be seen clearly. Neoplasm can be seen in delayed phase in 99m Tc-MIBI groups, but not easy to distinguish them from inflammation. Conclusion: Compared with 99m Tc-MIBI imaging, 99m Tc-HL91 has much more diagnostic value in detection of solid neoplasm, and can distinguish neoplasm from inflammation

  16. Experimental ion mobility measurements in Ne-N2

    International Nuclear Information System (INIS)

    Cortez, A.F.V.; Encarnação, P.M.C.C.; Santos, F.P.; Borges, F.I.G.M.; Conde, C.A.N.; Veenhof, R.; Neves, P.N.B.

    2016-01-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors, such as the ALICE TPC or in the NEXT experiment. In the present work the method, experimental setup and results for the ion mobility measurements in Ne-N 2 mixtures are presented. The results for this mixture show the presence of two peaks for different gas ratios of Ne-N 2 , low reduced electric fields, E / N , 10–20 Td (2.4–4.8 kV·cm −1 ·bar −1 ), low pressures 6–8 Torr (8–10.6 mbar) and at room temperature.

  17. Experimental ion mobility measurements in Xe-CO2

    Science.gov (United States)

    Cortez, A. F. V.; Santos, M. A. G.; Veenhof, R.; Patra, R. N.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-06-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work the method, experimental setup and results for the ion mobility measurements in Xe-CO2 mixtures are presented. The results for this mixture show the presence of only one peak for all gas ratios of Xe-CO2, low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV·cm-1·bar-1), low pressures 6-8 Torr (8-10.6 mbar), at room temperature.

  18. Experimental measurements and modelling of the WEGA boundary layer plasma

    International Nuclear Information System (INIS)

    El Shaer, M.; Ichtchenko, G.

    1983-02-01

    The boundary layer of the WEGA Tokamak has been investigated by using specific diagnostics: movable 4 mm microwave interferometer, several types of movable and fixed probes, Katsumata probe, and multigrid electrostatic analyzer. During the RF heating at the lower hybrid frequency, some modifications in the parameters of the boundary layer are observed which are interpreted by the ponderomotive force effects. A comparison between the measured reflection coefficients of the grill waveguides and their predicted values by a coupling theory (not taking into account the real conditions facing the Grill) is presented. A diffusion model was also made to describe this particular region and to fit the experimental results

  19. The effect of steroid on FDG uptake in experimental tumors, granulomatous and inflammatory lesions

    International Nuclear Information System (INIS)

    Zhao Songji; Yuji Kuge; Kunihiro Nakada; Masayuki Sato; Toshiki Takei; Zhao Yan; Nagara Tamaki; Masashi Kohanawa; Ken-ichi Seki

    2004-01-01

    Objectives: FDG accumulates not only in malignant tumors but also inflammatory lesions, especially in granulomatous lesions, which makes differentiate malignant tumors from benign lesions difficult. To obtain a clue for differentiating malignant lesions from benign ones by FDG-PET, we determined the effect of steroid on FDG uptake in granulomatous and inflammatory lesions, and compared them with those in malignant tumors in rats. Methods: Rats were inoculated with a suspension of allogenic hepatoma cells (KDH-8), Bacille bili e de Calmette-Guerin-(BCG) or Staphylococcus aureus (S. aureus), or with turpentine oil into the left calf muscle. Two weeks after KDH-8, 19 days after BCG, or one week after S. aureus or turpentine oil inoculations, the rats were fasted overnight and divided into two subgroups (n=5-6, in each group): Prednisolone (PRE)-pretreated (Methylprednisolone acetate, 8 mg/kg body weight, i.m. injection 20 hour before the FDG intravenous injection) and control (untreated) groups. Radioactivity in tissues was determined one hour after i.v. injection of FDG. FDG uptake in tissues were expressed as the percentage of injected dose per gram of tissue after normalization to animal's weight (%ID/g tissue/kg body weight). Results: FDG uptake in the tumor, granulomatous and inflammatory lesions were shown in Table. In the untreated animals, remarkably higher accumulations of FDG were observed in the tumor and granulomatous lesions, compared with those in the inflammatory lesions induced by S. aureus and turpentine oil. There was no significant difference in the level of FDG uptake between the tumor and granulomatous lesions, and between the two inflammatory lesions. PRE pre-treatment significantly decreased the level of FDG uptake in granulomatous lesions induced by BCG, inflammatory lesions induced by S. aureus and turpentine oil to 52%, 73% and 76% of the control value, respectively. The level of FDG uptake in the tumor was not significantly decreased by PRE

  20. Advanced age negatively impacts survival in an experimental brain tumor model.

    Science.gov (United States)

    Ladomersky, Erik; Zhai, Lijie; Gritsina, Galina; Genet, Matthew; Lauing, Kristen L; Wu, Meijing; James, C David; Wainwright, Derek A

    2016-09-06

    Glioblastoma (GBM) is the most common primary malignant brain tumor in adults, with an average age of 64 years at the time of diagnosis. To study GBM, a number of mouse brain tumor models have been utilized. In these animal models, subjects tend to range from 6 to 12 weeks of age, which is analogous to that of a human teenager. Here, we examined the impact of age on host immunity and the gene expression associated with immune evasion in immunocompetent mice engrafted with syngeneic intracranial GL261. The data indicate that, in mice with brain tumors, youth conveys an advantage to survival. While age did not affect the tumor-infiltrating T cell phenotype or quantity, we discovered that old mice express higher levels of the immunoevasion enzyme, IDO1, which was decreased by the presence of brain tumor. Interestingly, other genes associated with promoting immunosuppression including CTLA-4, PD-L1 and FoxP3, were unaffected by age. These data highlight the possibility that IDO1 contributes to faster GBM outgrowth with advanced age, providing rationale for future investigation into immunotherapeutic targeting in the future. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Thermal dosimetry studies of ultrasonically induced hyperthermia in normal dog brain and in experimental brain tumors

    International Nuclear Information System (INIS)

    Britt, R.H.; Pounds, D.W.; Stuart, J.S.; Lyons, B.E.; Saxer, E.L.

    1984-01-01

    In a series of 16 acute experiments on pentobarbital anesthetized dogs, thermal distributions generated by ultrasonic heating using a 1 MHz PZT transducer were compared with intensity distributions mapped in a test tank. Relatively flat distributions from 1 to 3 cm have been mapped in normal dog brain using ''shaped'' intensity distributions generated from ultrasonic emission patterns which are formed by the interaction between compressional, transverse and flexural modes activated within the crystal. In contrast, these same intensity distributions generated marked temperature variations in 3 malignant brain tumors presumably due to variations in tumor blood flow. The results of this study suggest that a practical clinical system for uniform heating of large tumor volumes with varying volumes and geometries is not an achievable goal. The author's laboratory is developing a scanning ultrasonic rapid hyperthermia treatment system which will be able to sequentially heat small volume of tumor tissue either to temperatures which will sterilize tumor or to a more conventional thermal dose. Time-temperature studies of threshold for thermal damage in normal dog brain are currently in progress

  2. Correlation between magnetic resonance image and content of water and fat in experimental tumor

    International Nuclear Information System (INIS)

    Sato, Tachio; Yamada, Kenji; Yamada, Susumu; Yoshioka, Seiro; Ono, Shuichi; Hishinuma, Takashi; Abe, Yoshinao; Matsuzawa, Taiju; Ogata, Yuko.

    1987-01-01

    Water and fat are considered to be major protons contributing to magnetic resonance (MR) signals in living tissues. This study compared proton density and T1 and T2 relaxation times with content of water and fat in tumor bearing rabbits. MR scans were performed using a Carr-Purcell-Meiboom-Gill pulse sequence with short and long repetition times. There was a strong correlation between proton density and the content of water and fat. The correlation of the content of water and fat to T1 and T2 relaxation times was not so strong as that to proton density. Viable tumor tissues had significantly shorter T2 relaxation time than the surrounding edematous tissues (p < 0.005), although the content of water and fat did not differ in the two types of tissues. T1 relaxation time did not differ in viable tumorous and edematous tissues. (Namekawa, K.)

  3. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (2)

    International Nuclear Information System (INIS)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Tsuchiya, Yoshiharu; Niitsu, Iwayasu; Hayashibara, Hiromi; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-01-01

    C3H/He mice transplanted syngeneic MM102 tumor subcutaneously in the footpad were used to study the timing of administration of lentinan when combined with local irradiation of X-ray. In combination with 1,000 rads irradiation, the administration of lentinan after X-ray was not effective. When lentinan was administered in combination with 2,000 to 3,000 rads irradiation, the growth of tumor was decreased significantly in comparison with the groups which received radiotherapy alone and those that received lentinan alone. The administration of lentinan before irradiation was effective at the same degree in the group that received lentinan after irradiation. Life prolongation effect was also observed in the group that received lentinan before and after irradiation, and 4 mice among 8 tested mice were survived at 70th day after tumor transplantation. (author)

  4. Variables affecting the tumor localization of 131I-antiferritin in experimental hepatoma

    International Nuclear Information System (INIS)

    Rostock, R.A.; Klein, J.L.; Kopher, K.A.; Order, S.E.

    1984-01-01

    Ferritin is both a normal tissue- and tumor-associated protein. The in vivo localization of 131 I-radiolabeled antitumor ferritin and normal IgG antibodies in the H-4-II-E rat hepatoma model was investigated in both tumor and normal tissues over a dose range of 0.67 micrograms to 5 mg of normal and antiferritin IgG and at labeling ratios (microCi 131 I per micrograms IgG) of 15:1, 5:1, and 1:10. The total dose from nonpenetrating radiation in rads was calculated and demonstrated a maximum of 2.9 times greater dose deposition (rads) of antiferritin than normal IgG in hepatoma without specific increase in binding in normal tissues. The maximum tumor targeting achieved was dependent on the amount of injected IgG and not on the labeling ratio or procedure. The binding in tumor could be inhibited by unlabeled antiferritin but not by unlabeled normal rabbit IgG and demonstrated the requirement of specificity for tumor binding. Normal tissues did not target with antiferritin. Most normal tissues have a capacity to bind normal and antiferritin IgG nonspecifically that is linear in relationship to the amount of injected IgG. The results demonstrate that 131 I-antiferritin selectively targets ferritin-secreting hepatoma over normal tissues and that the amount of targeting is dependent on the amount of antiferritin injected. The physiologic reasons for such selective localization is not known, but the term ''biologic window'' has been used to describe the differential availability of tumor ferritin for binding

  5. Methodological fundamentals of experimental magneto-therapy of tumors (historical essay

    Directory of Open Access Journals (Sweden)

    Alla I. Shikhlyarova

    2015-11-01

    Full Text Available The paper highlights the key stages on the way of a proper understanding of the magnetic field anti-tumor influence mechanisms on the level of an organism as an integrated system and its individual subsystems. The experiments in animals have shown that the processes of the malignant tumor growth inhibition are closely related to the formation of the stable state of the activation reaction at high reactivity levels. It is noted that the induction of such adaptational reaction depends on a specified selection of parameters of exposure intensities and magnetic field frequency, taking into account the law of nonlinearity of an exposure effect and adequacy with endogenous rhythms.

  6. Efficacy and toxicity in brain tumor treatment - quantitative Measurements using advanced MRI

    DEFF Research Database (Denmark)

    Ravn, Søren

    2016-01-01

    From the clinical introduction in the 1980s, MRI has grown to become an indispensable brain imaging modality, mainly due to its excellent ability to visualize soft tissues. Morphologically, T1- and T2-weighted brain tumor MRI have been part of routine diagnostic radiology for more than two decades...... with the introduction of magnets with higher field strength. Ongoing technical development has enabled a change from semiquantitative measurements to a true quantitative approach. This step is expected to have a great impact on the treatment of brain tumor patients in the future. The aim of this Ph.D. dissertation...... was to explore how different advanced MRI techniques could contribute to a higher degree of individualized treatment of brain tumor patients. The thesis is based on three studies in which advanced MRI is used to evaluate the possible role of fMRI in presurgical planning, Diffusion Tensor Imaging (DTI...

  7. Deriving Structural Information from Experimentally Measured Data on Biomolecules.

    Science.gov (United States)

    van Gunsteren, Wilfred F; Allison, Jane R; Daura, Xavier; Dolenc, Jožica; Hansen, Niels; Mark, Alan E; Oostenbrink, Chris; Rusu, Victor H; Smith, Lorna J

    2016-12-23

    During the past half century, the number and accuracy of experimental techniques that can deliver values of observables for biomolecular systems have been steadily increasing. The conversion of a measured value Q exp of an observable quantity Q into structural information is, however, a task beset with theoretical and practical problems: 1) insufficient or inaccurate values of Q exp , 2) inaccuracies in the function Q(r→) used to relate the quantity Q to structure r→ , 3) how to account for the averaging inherent in the measurement of Q exp , 4) how to handle the possible multiple-valuedness of the inverse r→(Q) of the function Q(r→) , to mention a few. These apply to a variety of observable quantities Q and measurement techniques such as X-ray and neutron diffraction, small-angle and wide-angle X-ray scattering, free-electron laser imaging, cryo-electron microscopy, nuclear magnetic resonance, electron paramagnetic resonance, infrared and Raman spectroscopy, circular dichroism, Förster resonance energy transfer, atomic force microscopy and ion-mobility mass spectrometry. The process of deriving structural information from measured data is reviewed with an eye to non-experts and newcomers in the field using examples from the literature of the effect of the various choices and approximations involved in the process. A list of choices to be avoided is provided. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Inhibition of the release of soluble tumor necrosis factor receptors in experimental endotoxemia by an anti-tumor necrosis factor-alpha antibody

    NARCIS (Netherlands)

    Jansen, J.; van der Poll, T.; Levi, M. [=Marcel M.; ten Cate, H.; Gallati, H.; ten Cate, J. W.; van Deventer, S. J.

    1995-01-01

    The role of tumor necrosis factor-alpha in the shedding of soluble tumor necrosis factor receptors in endotoxemia was investigated. The appearance of the soluble tumor necrosis factor receptors was assessed in four healthy volunteers following an intravenous injection of tumor necrosis factor-alpha

  9. Effective experimental tumor therapy with targeted polymer drug delivery systems based on HPMA copolymers.

    Czech Academy of Sciences Publication Activity Database

    Šírová, Milada; Horková, Veronika; Sivák, Ladislav; Etrych, Tomáš; Říhová, Blanka; Studenovský, Martin

    SI (2016), s. 24-24 ISSN 0014-2980. [3rd Meeting of Middle – European Societies for Immunology and Allergology. 01.12.2016-03.12.2016, Budapest ] R&D Projects: GA ČR(CZ) GA14-12742S Institutional support: RVO:61388971 ; RVO:61389013 Keywords : Tumor therapy * polymer drug * HPMA copolymers Subject RIV: EE - Microbiology, Virology

  10. View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application.

    Directory of Open Access Journals (Sweden)

    Pia M Jungmann

    Full Text Available MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts.To evaluate the benefit of view-angle tilting (VAT and slice-encoding metal artifact correction (SEMAC for MRI of large-sized orthopaedic tumor endoprostheses in an experimental model and to demonstrate clinical benefits for assessment of periprosthetic soft tissue abnormalities.In an experimental setting, tumor endoprostheses (n=4 were scanned at 1.5T with three versions of optimized high-bandwidth turbo-spin-echo pulse sequences: (i standard, (ii VAT and (iii combined VAT and SEMAC (VAT&SEMAC. Pulse sequences included coronal short-tau-inversion-recovery (STIR, coronal T1-weighted (w, transverse T1-w and T2-w TSE sequences. For clinical evaluation, VAT&SEMAC was compared to conventional metal artifact-reducing MR sequences (conventional MR in n=25 patients with metal implants and clinical suspicion of tumor recurrence or infection. Diameters of artifacts were measured quantitatively. Qualitative parameters were assessed on a five-point scale (1=best, 5=worst: "image distortion", "artificial signal changes at the edges" and "diagnostic confidence". Imaging findings were correlated with pathology. T-tests and Wilcoxon-signed rank tests were used for statistical analyses.The true size of the prostheses was overestimated on MRI (P<0.05. A significant reduction of artifacts was achieved by VAT (P<0.001 and VAT&SEMAC (P=0.003 compared to the standard group. Quantitative scores improved in the VAT and VAT&SEMAC group (P<0.05. On clinical MR images, artifact diameters were significantly reduced in the VAT&SEMAC-group as compared with the conventional-group (P<0.001. Distortion and artificial signal changes were reduced and diagnostic confidence improved (P<0.05. In two cases, tumor-recurrence, in ten cases infection and in thirteen cases other

  11. Experimental measurements in the BYU controlled profile reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tree, D.R.; Black, D.l.; Rigby, J.R.; McQuay, M.Q.; Webb, B.W. [Brigham Young University, Provo, UT (United States). Dept. of Mechanical Engineering

    1998-09-01

    Over the past decade the Controlled Profile Reactor (CPR) has been used to obtain extensive combustion data sets. CPR is a small scale (0.2-0.4 MW) combustion facility that has been used to obtain data for model validation, the testing of new combustion concepts, and the development of new combustion instruments. This review of the past ten years of research completed in the CPR includes a description of the reactor and instrumentation used, a summary of three experimental data sets which have been obtained in the reactor, and a description of novel tests and instrumentation. Measurements obtained include gas species, gas temperature, particle velocity, particle size, particle number density, particle-cloud temperature profiles, radiation and total heat flux to the wall, and wall temperatures. Species data include the measurement of CO, CO{sub 2}, NO, NO{sub x}, O{sub 2}, NH{sub 3} and HCN. The three combustion studies included one with natural gas combustion in a swirling flow, and two pulverized-coal combustion studies involving Utah Blind Canyon and Pittsburgh No. 8 coals. Most, but not all of the above measurements were obtained in each study. The second coal study involving the Pittsburgh No. 8 coal contained the most complete set of data and is described in detail. Novel combustion instrumentation includes the use of Coherent Anti-Stokes Raman Spectroscopy (CARS) to measure gas temperature. Novel combustion experiments include the measurement of NO{sub x} and burnout with coal-char blends. The measurements have led to an improved understanding of the combustion process and an understanding of the strengths and weaknesses associated with different aspects of comprehensive combustion models. 67 refs., 26 figs., 9 tabs.

  12. Dendritic Cells in the Context of Human Tumors: Biology and Experimental Tools.

    Science.gov (United States)

    Volovitz, Ilan; Melzer, Susanne; Amar, Sarah; Bocsi, József; Bloch, Merav; Efroni, Sol; Ram, Zvi; Tárnok, Attila

    2016-01-01

    Dendritic cells (DC) are the most potent and versatile antigen-presenting cells (APC) in the immune system. DC have an exceptional ability to comprehend the immune context of a captured antigen based on molecular signals identified from its vicinity. The analyzed information is then conveyed to other immune effector cells. Such capability enables DC to play a pivotal role in mediating either an immunogenic response or immune tolerance towards an acquired antigen. This review summarizes current knowledge on DC in the context of human tumors. It covers the basics of human DC biology, elaborating on the different markers, morphology and function of the different subsets of human DC. Human blood-borne DC are comprised of at least three subsets consisting of one plasmacytoid DC (pDC) and two to three myeloid DC (mDC) subsets. Some tissues have unique DC. Each subset has a different phenotype and function and may induce pro-tumoral or anti-tumoral effects. The review also discusses two methods fundamental to the research of DC on the single-cell level: multicolor flow cytometry (FCM) and image-based cytometry (IC). These methods, along with new genomics and proteomics tools, can provide high-resolution information on specific DC subsets and on immune and tumor cells with which they interact. The different layers of collected biological data may then be integrated using Immune-Cytomics modeling approaches. Such novel integrated approaches may help unravel the complex network of cellular interactions that DC carry out within tumors, and may help harness this complex immunological information into the development of more effective treatments for cancer.

  13. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy

    International Nuclear Information System (INIS)

    Seppenwoolde, Yvette; Shirato, Hiroki; Kitamura, Kei; Shimizu, Shinichi; Herk, Marcel van; Lebesque, Joos V.; Miyasaka, Kazuo

    2002-01-01

    patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement. The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments. Conclusion: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors

  14. Effect of Electron Seeding on Experimentally Measured Multipactor Discharge Threshold

    Science.gov (United States)

    Noland, Jonathan; Graves, Timothy; Lemon, Colby; Looper, Mark; Farkas, Alex

    2012-10-01

    Multipactor is a vacuum phenomenon in which electrons, moving in resonance with an externally applied electric field, impact material surfaces. If the number of secondary electrons created per primary electron impact averages more than unity, the resonant interaction can lead to an electron avalanche. Multipactor is a generally undesirable phenomenon, as it can cause local heating, absorb power, or cause detuning of RF circuits. In order to increase the probability of multipactor initiation, test facilities often employ various seeding sources such as radioactive sources (Cesium 137, Strontium 90), electron guns, or photon sources. Even with these sources, the voltage for multipactor initiation is not certain as parameters such as material type, RF pulse length, and device wall thickness can all affect seed electron flux and energy in critical gap regions, and hence the measured voltage threshold. This study investigates the effects of seed electron source type (e.g., photons versus beta particles), material type, gap size, and RF pulse length variation on multipactor threshold. In addition to the experimental work, GEANT4 simulations will be used to estimate the production rate of low energy electrons (< 5 keV) by high energy electrons and photons. A comparison of the experimental fluxes to the typical energetic photon and particle fluxes experienced by spacecraft in various orbits will also be made. Initial results indicate that for a simple, parallel plate device made of aluminum, there is no threshold variation (with seed electrons versus with no seed electrons) under continuous-wave RF exposure.

  15. Experimental Measurements of Prestressed Masonry with using Sliding Joint

    Directory of Open Access Journals (Sweden)

    Stara Marie

    2014-06-01

    Full Text Available Contribution deals with experimental measurements of deformations in the place exposed to local load caused by additional pre-stressing. The measurements are made at the masonry corner built in the laboratory equipment. The laboratory equipment was designed at Faculty of Civil Engineering VŠB-Technical University of Ostrava for measurement tri-axial stress-strain conditions in masonry. In this masonry corner two pre-stressing bars are placed. These bars are in different height and are anchored to the anchor plates, which transfer pre-stressing forces to the masonry. The specimen for laboratory testing is performed in the proportion to the reality of 1:1. In the bottom part masonry is inserted asphalt strip. It operates in the masonry like a sliding joint and reduces the shear stress at interface between concrete and masonry structures. The results are compared with the results of masonry without the use of sliding joints, including comment on the effect of sliding joints on the pre-stressing masonry structures.

  16. Experimental arrangement to measure dispersion in optical fiber devices

    Energy Technology Data Exchange (ETDEWEB)

    Armas Rivera, Ivan [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias de la Electronica (Mexico); Beltran Perez, Georgina; Castillo Mixcoatl, Juan; Munoz Aguirre, Severino [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Fisico Matematicas (Mexico); Zaca Moran, Placido, E-mail: ivan_rr1@hotmail.com [Benemerita Universidad Autonoma de Puebla, Fisicoquimica de Materiales ICUAP (Mexico)

    2011-01-01

    Dispersion is a quite important parameter in systems based on optical fiber, especially in pulsed emission lasers, where the temporal width is affected by such parameter. Therefore, it is necessary to consider the dispersion provoked by each component in the cavity. There are various experimental interferometric arrangements to evaluate this parameter. Generally, these systems modify the wavelength to obtain information about the n({lambda}) dependency, which is contained in the interferogram phase. However, this makes the system quite slow and it requires tunable and narrow bandwidth laser sources. In the present work, results obtained from an arrangement based on Mach-Zehnder interferometer where one of the arms is the optical fiber under study, while the reference one is air, are presented. In order to determine the n({lambda}) dependency, a wide spectrum light source was used in the wavelength range of interest. The phase information was evaluated from the interferometric signal measured by an optical spectrum analyzer.

  17. Experimental ion mobility measurements in Xe-CH4

    Science.gov (United States)

    Perdigoto, J. M. C.; Cortez, A. F. V.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-09-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work, the method, experimental setup and results for the ion mobility measurements in Xe-CH4 mixtures are presented. The results for this mixture show the presence of two distinct groups of ions. The nature of the ions depend on the mixture ratio since they are originated by both Xe and CH4. The results here presented were obtained for low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV ṡ cm-1 ṡ bar-1), at low pressure (8 Torr) (10.6 mbar), and at room temperature.

  18. Experimental testing facilities for ultrasonic measurements in heavy liquid metal

    International Nuclear Information System (INIS)

    Cojocaru, V.; Ionescu, V.; Nicolescu, D.; Nitu, A.

    2016-01-01

    The thermo-physical properties of Heavy Liquid Metals (HLM), like lead or its alloy, Lead Bismuth Eutectic (LBE), makes them attractive as coolant candidates in advanced nuclear systems. The opaqueness, that is common to all liquid metals, disables all optical methods. For this reason ultrasound waves are used in different applications in heavy liquid metal technology, for example for flow and velocity measurements and for inspection techniques. The practical use of ultrasound in heavy liquid metals still needs to be demonstrated by experiments. This goal requires heavy liquid metal technology facility especially adapted to this task. In this paper is presented an experimental testing facility for investigations of Heavy Liquid Metals acoustic properties, designed and constructed in RATEN ICN. (authors)

  19. Experimental arrangement to measure dispersion in optical fiber devices

    International Nuclear Information System (INIS)

    Armas Rivera, Ivan; Beltran Perez, Georgina; Castillo Mixcoatl, Juan; Munoz Aguirre, Severino; Zaca Moran, Placido

    2011-01-01

    Dispersion is a quite important parameter in systems based on optical fiber, especially in pulsed emission lasers, where the temporal width is affected by such parameter. Therefore, it is necessary to consider the dispersion provoked by each component in the cavity. There are various experimental interferometric arrangements to evaluate this parameter. Generally, these systems modify the wavelength to obtain information about the n(λ) dependency, which is contained in the interferogram phase. However, this makes the system quite slow and it requires tunable and narrow bandwidth laser sources. In the present work, results obtained from an arrangement based on Mach-Zehnder interferometer where one of the arms is the optical fiber under study, while the reference one is air, are presented. In order to determine the n(λ) dependency, a wide spectrum light source was used in the wavelength range of interest. The phase information was evaluated from the interferometric signal measured by an optical spectrum analyzer.

  20. Efficacy of magnetoacustoradiation treatment of experimental M-1, PC-1 tumors

    International Nuclear Information System (INIS)

    Chizh, D.V.; Krutilina, N.I.

    2011-01-01

    The urgency of the struggle against malignant tumors is determined by a stable growth of cancer incidence, high level of disability and morbidity, the cost and difficulty of treatment. The influence of low-frequency ultrasound and alternating magnetic field on transplanted tumors of sarcoma M-1 and alveolar liver cancer PC-1 together with radiation therapy at a SFD of 5 Gy and 20 Gy was investigated in the experiments on animals. It was established that the influence of the above physical factors inhibited sarcoma M-1 and alveolar liver cancer PC-1 growth, prolonged the life and survival of the animals of the investigated groups when compared to the intact controls, which definitely expanded the ideas about the capabilities of ultrasound and magnetic fields in cancer treatment.

  1. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (3)

    International Nuclear Information System (INIS)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Niitsu, Iwayasu; Hayashibara, Hiromi; Tsuchiya, Yoshiharu; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-01-01

    Combination effect of lentinan with X-ray irradiation on the metastatic mouse tumors, L1210, KLN205 and Lewis lung carcinoma were studied. Combination use of lentinan with X-ray therapy prolonged the life of BDF 1 mice bearing L1210 leukemia in the suitable combination conditions. Combination effects of lentinan with X-ray therapy were also observed on the suppression of the growth of KLN205 squamus cell carcinoma and on the suppression of the metastasis of Lewis lung carcinoma. Especially, in the case that lentinan was administered before or after X-ray local irradiation in the pulmorary metastasis system of Lewis lung carcinoma, a marked suppressin of pulmonary metastasis was observed and 2 to 4 mice among 8 tested mice were tumor free. (author)

  2. Treatment schedule of combination using radiation and ACNU in the experimental brain tumors

    International Nuclear Information System (INIS)

    Kaneko, Sadao; Allen, N.J.; Clendenon, N.R.; Kartha, M.

    1983-01-01

    This study was undertaken to identify the combined effect of ACNU treatment and irradiation in a rat (CD Fisher) brain tumor model, which was produced by stereotaxic inoculation of F-98 or D-74 glioma clone cells. In the first series using F-98, the median survival time of the controls was 38 days. ACNU alone (7 mg/kg x 3) on Day 5, 6 and 7 following tumor cell inoculation resulted in 45 days, a single dose of irradiation alone (1,500 rads) on Day 8 produced 45 days and the combined treatment resulted in 58 days with a 28.9% increased life span (%ILS). In the second series using D-74, the median survival time of the control group was 20 days. ACNU alone (7 mg/kg x 3) showed no significant increase in survival time. A single dose of irradiation resulted in 23 days and the combined treatment in 26 days with 13.0%ILS. The third series assessed the schedule dependence of the combined treatment effects of ACNU and irradiation using D-74. The median survival time of the controls was 21 days. A single dose of ACNU (20 mg/kg) produced no significant increase. Irradiation alone (1,500 rads) on Day 8 resulted in 26 days. Combined treatment groups receiving ACNU 1 hour and 3 days prior to irradiation showed a significant increase (31 days with 19.2%ILS and 28.5 days with 9.6%ILS, respectively). However, survival times in the groups receiving ACNU 6 or 26 hours prior to irradiation, as well as 6 hours following irradiation, were not significantly longer than those in the group of irradiation alone. No significant difference in tumor size at the time of death was noted among any of the groups. Combined use of ACNU and irradiation may have a synergistic effect on the rat brain tumor model, and this effect depends on the combination schedule. (J.P.N.)

  3. Tumor Microenvironment In Experimental Models Of Human Cancer: Morphological Investigational Approaches

    Directory of Open Access Journals (Sweden)

    Lucia Minoli

    2017-05-01

    Discussion and conclusions. Due to the microenvironmental heterogeneity which influence tumor development and biological behavior, a sole quantification is unreliable for characterizing the TME. Considering that, morphological techniques proved to be a valuable approach, allowing the evaluation of the spatial distribution and mutual interaction between the different elements. Additional studies are needed for further investigate the biological significance of spatial distribution of the components of the TME.

  4. Measuring Diagnostic Stand for Experimental Researches in Technology Machining

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2014-01-01

    Full Text Available The paper reviews applied techniques, methods, and structure of the control and measuring means to conduct experimental and scientific researches of cutting processes. Existing research methods in cutting the metals are divided by features, such as essence of methods, the number of records of physical indicators, the number of studied factors, duration of tests. The groups of methods are briefly characterized.The chair "Tool Engineering and Technologies" of BMSTU developed and made a diagnostic stand of control and measurements for conducting research activities in the field of materials processing technology by cutting to define rational technological decisions, when machining, and carry out an analysis of efficiency and economic feasibility of made decisions. The diagnostic stand contains modern the electronic equipment. Record of measuring parameters is made in real time with a possibility for visual representation of read results and mathematical and statistical processing of measurement results. The stand can be used in research laboratories of machine-building enterprises, laboratories of higher education institutions, and other scientific divisions.The paper presents a justification that the stand is reasonable to use for the following: completion and choice of rational cutting modes, workability assessment of new constructional materials, technical and operational characteristics of the processed surfaces, and operational properties of the cutting tools of various producers, choice of optimum geometrical parameters of the cutting tools and brands of the lubricant cooling technological means, as well as the energy consumption for the chosen machining process. The stand allows us to make an assessment of wear resistance and tribology-technical characteristics of tool materials, as well as an accuracy, rigidity, vibration stability of machines, both new and being in operation.

  5. THE EFFECT OF ASCORBIC ACID ON PATHOHISTOLOGICAL TUMOR CHARACTERISTICS AND PHENOTYPE CHARACTERISTICS OF LYMPHOCYTES DURING THE DEVELOPMENT OF EXPERIMENTAL MAMMARY CARCINOMA IN MICE

    Directory of Open Access Journals (Sweden)

    Voja Pavlovic

    2005-04-01

    Full Text Available TIn our previous study we demonstrated that high doses of ascorbic acid prolonged the survival of mice with experimental mammary carcinoma. In this work we studied, ussing the same model, pathohistological characteristics of the tumor and phenotypic changes of lymphocyte subsets in the spleen. Experiments were performed on CBA/H mice. The growh of experimental tumor was induced by injection of mammary adenocarcinoma cells intramuscularly at the femoral region of mice. The animals were divided into control group and three experimental groups (I, II and III. Mice from experimental groups were treated peroraly with 10, 100 and 1000 mg/kg body mass (b.m. of ascorbic acid, respectively, whereas control mice received physiological saline. Mice were sacrified after 7, 14 and 21 days from the beginning of the experiment. Total tumor mass and its pathohistological characteristics, spleen mass and cellularity as well as relative and total numbers of T cells, B cells and T cell subsets (CD4+ and CD8+ in the spleen, were analyzed. High doses of ascorbic acid decreased tumor mass, stimulated proliferation of fibroblasts and formation of capsula arround the tumor, induced tumor necrosis and increased the number of tumor infiltrating lymphocytes. Changes of lymphocyte subsets and their numbers varied depending on the applied dose of ascorbic acid and the time elapsed following tumor induction. The most prominent changes, manifested by an increase in the number of CD4+ T cells were observed on the 14th day in II experimental group. Our results suggest that the beneficial effect of ascorbic acid on experimental tumorogenesis in our model was the consequence of its influence on the tumor and on the immune system.

  6. Experimental evaluation of a MOSFET dosimeter for proton dose measurements

    International Nuclear Information System (INIS)

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-01-01

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations

  7. Measurement of P-31 MR relaxation times and concentrations in human brain and brain tumors

    International Nuclear Information System (INIS)

    Roth, K.; Naruse, S.; Hubesch, B.; Gober, I.; Lawry, T.; Boska, M.; Matson, G.B.; Weiner, M.W.

    1987-01-01

    Measurements of high-energy phosphates and pH were made in human brain and brain tumors using P-31 MR imaging. Using a Philips Gyroscan 1.5-T MRMRS, MR images were used to select a cuboidal volume of interest and P-31 MR spectra were obtained from that volume using the ISIS technique. An external quantitation standard was used. T 1 s were measured by inversion recovery. Quantitative values for metabolites were calculated using B 1 field plot of the head coil. The results for normal brain phosphates are as follows; adenosine triphosphate, 2.2 mM; phosphocreatin, 5.3 mM; inorganic phosphate, 1.6 mM. Preliminary studies with human brain tumors show a decrease of all phosphate compounds. These experiments are the first to quantitate metabolites in human brain

  8. GROWTH FACTORS AND COX2 IN WOUND HEALING: AN EXPERIMENTAL STUDY WITH EHRLICH TUMORS.

    Science.gov (United States)

    Salgado, Flávio L L; Artigiani-Neto, Ricardo; Lopes-Filho, Gaspar de Jesus

    2016-01-01

    Healing is an innate biological phenomenon, and carcinogenesis acquired, but with common humoral and cellular elements. Carcinogenesis interferes negatively in healing. To evaluate the histological changes in laparotomy scars of healthy Balb/c mice and with an Ehrlich tumor in its various forms of presentation. Fifty-four mice were divided into three groups of 18 animals. First group was the control; the second had Ehrlich tumor with ascites; and the third had the subcutaneous form of this tumor. Seven days after tumor inoculation, all 54 mice were submitted to laparotomy. All of the animals in the experiment were operated on again on 7th day after surgery, with resection of the scar and subsequent euthanasia of the animal. The scars were sent for histological assessment using immunohistochemical techniques to evaluate Cox-2 (cyclooxygenase 2), VEGF (vascular endothelial growth factor) and FGF (fibroblast growth factor). Semi-quantitatively analysis was done in the laparotomy scars and in the abdominal walls far away from the site of the operation. Assessing the weight of the animals, the correct inoculation of the tumor and weight gain in the group with tumoral ascites was observed. The histological studies showed that groups with the tumor showed a statistically significant higher presence of Cox-2 compared to the control. In the Cox-2 analysis of the abdominal wall, the ascites group showed the most significant difference. VEGF did not present any significant differences between the three groups, regardless of the site. The FGF showed a significant increase in animals with the tumor. Histological findings in both laparotomy scar and the abdominal wall showed that with Ehrlich's neoplasia there was an exacerbated inflammatory response, translated by more intense expression of Cox-2 and greater fibroblast proliferation, translated by more intense expression of FGF, that is, it stimulated both the immediate inflammatory reactions, observed with Cox-2 reactions, and

  9. Contrast-enhanced near-infrared laser mammography with a prototype breast scanner: feasibility study with tissue phantoms and preliminary results of imaging experimental tumors.

    Science.gov (United States)

    Boehm, T; Hochmuth, A; Malich, A; Reichenbach, J R; Fleck, M; Kaiser, W A

    2001-10-01

    Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent detectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed. The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 x 2 cm2 without contrast was replaced with phantom material containing 1 micromol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda1 = 785 nm and lambda2 = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 micromol/kg NIR96010. Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 micromol/L. At concentrations contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption profiles, a 44.1% +/- 11.3% greater absorption increase was seen in tumor tissue compared with normal tissue. The laser wavelength lambda1 of the prototype laser mammography device was not situated at maximum absorption of the contrast agent NIR96010 but on the descending shoulder of the absorption spectrum. This implies a 20

  10. Intensity-Curvature Measurement Approaches for the Diagnosis of Magnetic Resonance Imaging Brain Tumors

    Directory of Open Access Journals (Sweden)

    Carlo Ciulla

    2015-11-01

    Full Text Available This research presents signal-image post-processing techniques called Intensity-Curvature Measurement Approaches with application to the diagnosis of human brain tumors detected through Magnetic Resonance Imaging (MRI. Post-processing of the MRI of the human brain encompasses the following model functions: (i bivariate cubic polynomial, (ii bivariate cubic Lagrange polynomial, (iii monovariate sinc, and (iv bivariate linear. The following Intensity-Curvature Measurement Approaches were used: (i classic-curvature, (ii signal resilient to interpolation, (iii intensity-curvature measure and (iv intensity-curvature functional. The results revealed that the classic-curvature, the signal resilient to interpolation and the intensity-curvature functional are able to add additional information useful to the diagnosis carried out with MRI. The contribution to the MRI diagnosis of our study are: (i the enhanced gray level scale of the tumor mass and the well-behaved representation of the tumor provided through the signal resilient to interpolation, and (ii the visually perceptible third dimension perpendicular to the image plane provided through the classic-curvature and the intensity-curvature functional.

  11. Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

    International Nuclear Information System (INIS)

    Nakamura, Mitsuhiro; Miyabe, Yuki; Matsuo, Yukinori; Kamomae, Takeshi; Nakata, Manabu; Yano, Shinsuke; Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-01-01

    The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A 1 ) was set in the range of 0.0–12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of γ index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within ± 0.7%. From the dose area histograms on the film, the mean ± standard deviation of the dose covering 100% of the cross section of the target was 102.32 ± 1.20% (range, 100.59–103.49%). By contrast, the irradiated areas receiving more than 95% dose for A 1 = 12 mm were 1.46 and 1.33 times larger than those for A 1 = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

  12. Reevaluating the Concept of Treating Experimental Tumors with a Mixed Bacterial Vaccine: Coley’s Toxin

    Directory of Open Access Journals (Sweden)

    C. Maletzki

    2012-01-01

    Full Text Available Several decades after Coley’s initial work, we here systematically analyzed tumoricidal as well as immunostimulatory effects of the historical preparation Coley’s Toxin (CT, a safe vaccine made of heat-inactivated S. pyogenes and S. marcescens. First, by performing in vitro analysis, established human pancreatic carcinoma cell lines responded with dose- and time-dependent growth inhibition. Effects were attributed to necrotic as well as apoptotic cell death as determined by increased Caspase 3/7 levels, raised numbers of cells with sub-G1-DNA, and induced p expression, indicative for cell cycle arrest. Besides, CT effectively stimulated human peripheral blood leukocytes (huPBL from healthy volunteers. Quantitative gene expression analysis revealed upregulated mRNA levels of selected Toll-like receptors. Flow cytometric phenotyping of CT-stimulated huPBLs identified raised numbers of CD25+-activated leukocytes. In vivo, repetitive, local CT application was well tolerated by animals and induced considerable delay of Panc02 tumors. However, systemic treatment failed to affect tumor growth. Antitumoral effects following local therapy were primarily accompanied by stimulation of innate immune mechanisms. Data presented herein prove that the historical approach of using killed bacteria as active immunotherapeutic agents still holds promise, and further careful preclinical analyses may pave the way back into clinical applications.

  13. Experimental study of ERT monitoring ability to measure solute dispersion.

    Science.gov (United States)

    Lekmine, Grégory; Pessel, Marc; Auradou, Harold

    2012-01-01

    This paper reports experimental measurements performed to test the ability of electrical resistivity tomography (ERT) imaging to provide quantitative information about transport parameters in porous media such as the dispersivity α, the mixing front velocity u, and the retardation factor R(f) associated with the sorption or trapping of the tracers in the pore structure. The flow experiments are performed in a homogeneous porous column placed between two vertical set of electrodes. Ionic and dyed tracers are injected from the bottom of the porous media over its full width. Under such condition, the mixing front is homogeneous in the transverse direction and shows an S-shape variation in the flow direction. The transport parameters are inferred from the variation of the concentration curves and are compared with data obtained from video analysis of the dyed tracer front. The variations of the transport parameters obtained from an inversion performed by the Gauss-Newton method applied on smoothness-constrained least-squares are studied in detail. While u and R(f) show a relatively small dependence on the inversion procedure, α is strongly dependent on the choice of the inversion parameters. Comparison with the video observations allows for the optimization of the parameters; these parameters are found to be robust with respect to changes in the flow condition and conductivity contrast. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  14. Effects of cysteamine on pituitary, MTTW15 tumor, and serum prolactin levels measured by rat lymphoma cell bioassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Parsons, J.A.; Peterson, E.K.; Hartfel, M.A.

    1984-01-01

    Cysteamine (CSH), a sulfhydryl compound, reduces both serum and anterior pituitary (AP) PRL measured by RIA. We have used the Nb2 lymphoma cell bioassay (BIO) for PRL to evaluate possible CSH-related changes in PRL levels in sera and tissues of male and MtTW15 mammosomatotropic tumor-bearing female rats. Experimental animals received a single sc injection of CSH (300 mg/kg), and samples were collected 0.5-24 h later. Since CSH and serum from CSH rats were toxic in BIO, samples were dialyzed before assay. All samples were evaluated for PRL and GH by RIA as well. A significant decrease (P less than 0.05) in BIO serum PRL was evident in male rats 0.5 h after CSH; levels remained low for 24 h. Serum PRL by RIA was significantly depressed at 4 h but not at 0.5 h or 24 h. PRL in AP extracts was decreased (60-90%) at all times by BIO and RIA. Significant decreases of BIO- and RIA-detectable PRL were recorded in serum and tissues (AP and tumors) at 4 h in tumor rats. Sequentially bled (0.5-4 h) CSH-treated tumor-bearing rats showed 50% and 80% reductions in serum PRL at 1 and 4 h by both BIO and RIA. CSH had no effect on GH levels in sera and tissues of any animal studied at any time interval. Our results substantiate earlier reports on CSH-induced decreases in RIA-detectable PRL. They show that such changes cannot be attributed to assay effects alone, as significant decreases in circulating and stored PRL (both AP and tumor) were evident by BIO. Results with tissue extracts were the most dramatic. They suggest an action of CSH or a metabolic intermediate with stored PRL which reduces both extractable PRL and hormone release. Such an effect of CSH on PRL extraction has been suggested by others. Whatever the mechanism, it appears to be relatively specific, since GH cells were not affected

  15. Measuring interstitial pH and pO2 in mouse tumors.

    Science.gov (United States)

    Jain, Rakesh K; Munn, Lance L; Fukumura, Dai

    2013-07-01

    This protocol outlines methods to measure two extravascular parameters, interstitial pH and partial pressure of oxygen (pO2), in mouse tumors. The method for measuring interstitial pH uses fluorescence ratio imaging microscopy (FRIM) of the pH-sensitive fluorescent dye 2',7'-bis-(2-carboxyethyl)-5,6-carboxyfluorescein (BCECF). The method for measuring interstitial pO2 is based on the oxygen-dependent quenching of the phosphorescence of albumin-bound palladium meso-tetra(4-carboxyphenyl)porphyrin, and can be used to measure microvascular as well as interstitial pO2. In addition, the two methods can be used sequentially to measure both pH and pO2 in the same tissues.

  16. Clinical and experimental studies on unilateral exophthalmos caused by intraorbital tumors

    International Nuclear Information System (INIS)

    Senoo, Kanehito

    1989-01-01

    Twenty eight patients with histologically confirmed intraorbital mass received transcranial surgery. According to the origin of mass, the patients were classified as having primary (15), secondary (4), metastatic (4), or pseudo-tumor (4) masses. Localization of intracranial masses fell into four types: the upper-lateral, medial, retrobulbar-apex, and diffuse types. The most common initial symptoms for the upper-lateral type and for the retrobulbar-apex type were exophtalmos and visual disturbance, respectively. Cranial X-rays and CT revealed bone destruction or proliferation and abnormal calcification in 57% of the patients. CAG revealed tumor stains in 18%. CT revealed the position and involvement of intraorbital mass. The ratio of the intraorbital mass to the orbital cavity area (the M/OC ratio) was calculated at the level of the optic nerve on CT scans. The M/OC ratio was correlated with the degree of impaired visual acuity. When it exceeded 50%, visual function was considerably disturbed. CT failed to discriminate between optic sheath meningioma and pyocele. The success rate of transcranial surgery, as evaluated by visual function recovery rate, was 46%. According to types, it was as high as 70% for the medial type. In an attempt to assess a correlation between the degree of exophthalmos and localization or volume of intraorbital mass, an experiment was made with a dry human skull, silicone rubber eye balls, gelatine and silicone balloons. When a mass more than 3 cm 3 in volume was in the lateral or medial part of the orbit, the rate of pressure increased. When it was in the apex part, the pressure gradually increased. These findings were in accordance with clinical findings. (N.K.) 73 refs

  17. Matching the reaction-diffusion simulation to dynamic [18F]FMISO PET measurements in tumors: extension to a flow-limited oxygen-dependent model.

    Science.gov (United States)

    Shi, Kuangyu; Bayer, Christine; Gaertner, Florian C; Astner, Sabrina T; Wilkens, Jan J; Nüsslin, Fridtjof; Vaupel, Peter; Ziegler, Sibylle I

    2017-02-01

    Positron-emission tomography (PET) with hypoxia specific tracers provides a noninvasive method to assess the tumor oxygenation status. Reaction-diffusion models have advantages in revealing the quantitative relation between in vivo imaging and the tumor microenvironment. However, there is no quantitative comparison of the simulation results with the real PET measurements yet. The lack of experimental support hampers further applications of computational simulation models. This study aims to compare the simulation results with a preclinical [ 18 F]FMISO PET study and to optimize the reaction-diffusion model accordingly. Nude mice with xenografted human squamous cell carcinomas (CAL33) were investigated with a 2 h dynamic [ 18 F]FMISO PET followed by immunofluorescence staining using the hypoxia marker pimonidazole and the endothelium marker CD 31. A large data pool of tumor time-activity curves (TAC) was simulated for each mouse by feeding the arterial input function (AIF) extracted from experiments into the model with different configurations of the tumor microenvironment. A measured TAC was considered to match a simulated TAC when the difference metric was below a certain, noise-dependent threshold. As an extension to the well-established Kelly model, a flow-limited oxygen-dependent (FLOD) model was developed to improve the matching between measurements and simulations. The matching rate between the simulated TACs of the Kelly model and the mouse PET data ranged from 0 to 28.1% (on average 9.8%). By modifying the Kelly model to an FLOD model, the matching rate between the simulation and the PET measurements could be improved to 41.2-84.8% (on average 64.4%). Using a simulation data pool and a matching strategy, we were able to compare the simulated temporal course of dynamic PET with in vivo measurements. By modifying the Kelly model to a FLOD model, the computational simulation was able to approach the dynamic [ 18 F]FMISO measurements in the investigated

  18. An experimental study on the low-dose radiosensitivity of tumor cell lines

    International Nuclear Information System (INIS)

    Kim, Min Sook; Koh, Kwang Joon

    1994-01-01

    The purpose of this study was to aid in the radiation therapy of head and neck cancer patients. For this study, radiation survival curves were generated for B16, MG-63 and YAC-1 cell lines using semiautomated MTT assay and Dye Exclusion Assay. Irradiation of 2, 4, 6, 8, 10 Gy were delivered at room temperature at a dose rate of 210.2 cGy/min using 60 COγ-ray irradiator ALDORADO 8. The viable cells were determined for each radiation dose and compared to control values. The obtained results were as follows: 1. The was significantly different absorbance at 10 Gy on B16 cell line in MTT assay (P<0.05). 2. There was significantly different absorbance at 4, 6, 8, 10 Gy on MG-63 cell line in MTT assay (P<0.05). 3. YAC-1 cell line was more sensitive than B16 or MG-63 cell line to all doses of radiation (P<0.05). 4. There was significantly different absorbance among all tumor cell lines except between B16 and MG-63 cell line at 2 Gy in MTT assay (P<0.05). 5. Good correlation was obtained between MTT assay and DEA (P<0.05). The efficient of correlation of B16, MG-63 and YAC-1 cell line was 0.845-0.824 and 0.906, respectively.

  19. Radiobiological hypoxic fraction does not correlate with pO2 measurements in eight human tumor xenografts into nude mice

    International Nuclear Information System (INIS)

    Taghian, A.; Huang, P.; Griffon, G.; Hartford, A.; Allam, A.; Costa, A. da; Kozin, S.; Suit, H.D.

    1997-01-01

    Purpose/Objective: Clinical and laboratory reports suggest that hypoxia limits local control probability in tumors treated by radiation. Significant increase in the TCD 50 (the dose of radiation needed to control 50% of the tumors) was obtained in a number of tumor models when the tumors were rendered hypoxic by clamping. Furthermore, recent data have shown the value of measuring the pO2 using electrodes in predicting the tumor response to radiation in cervical cancer. The aim of this study is to investigate the correlation between the radiobiological hypoxic fraction (HF) and the pO2 measurements of human tumor xenografts. Materials and Methods: Eight human tumor xenografts (five glioblastoma, one squamous cell carcinoma, one colon cancer, and one soft tissue sarcoma) were used in these experiments. Tumor chunks 2 mm in diameter were implanted into the hindleg of 5 Gy whole-body irradiated nude mice. When the tumor size reached 110 mm 3 , radiation was administered in a single dose ranging from 17.5 Gy to 90 Gy in hypoxic conditions. Acute hypoxia was induced by clamping the tumor bearing leg three minutes before and during the treatment. When aerobic conditions were required, the tumor bearing leg was immobilized by a hook which fitted around the ankle. Seven to 10 tumors were assigned to each dose level in each assay; there were 6 to 8 dose levels per assay. Starting at 2-3 weeks after irradiation, the animals were examined once per week and scored for presence of local tumor; if present, tumor diameters were measured. Tumor response is described in terms of radiation dose (in Gy) required to control 50% of the xenografts (TCD 50 ). The (HF) was determined using the formula of Howes (HF=e - ((TCD 50 hypoxic-TCD 50 air)(Do hypoxic)) and assuming an oxygen enhancement ratio of 3.0: (D o hyp=D o air x 3.0) (the D o air was separately determined in vitro for the corresponding cell lines). The pO2 measurements used electrodes as published (Boucher et al

  20. Nasopharyngeal Cancers: Which Method Should be Used to Measure these Irregularly Shaped Tumors on Cross-Sectional Imaging?

    International Nuclear Information System (INIS)

    King, Ann D.; Zee, Benny; Yuen, Edmund H.Y.; Leung Singfai; Yeung, David K.W.; Ma, Brigette B.; Wong, Jeffrey K.T.; Kam, Michael K.M.; Ahuja, Anil T.; Chan, Anthony T.C.

    2007-01-01

    Purpose: To determine whether the standard techniques of measuring tumor size and change in size after treatment could be applied to the measurement of nasopharyngeal cancers, which are often irregular in shape. Methods and Materials: The standard measurements of bidimensional (BDM) (World Health Organization criteria) and unidimensional (UDM) (Response Evaluation Criteria in Solid Tumors [RECIST] criteria), together with the maximum depth of the tumor perpendicular to the pharyngeal wall (DM), were acquired from axial magnetic resonance images of primary nasopharyngeal carcinoma in 44 patients at diagnosis and in 29 of these patients after treatment. Tumor volume measurements (VM), acquired from the summation of areas from the axial magnetic resonance images, were used as the reference standard. Results: There was a significant association between VM and BDM with respect to tumor size at diagnosis (p = 0.002), absolute change in tumor size after treatment (p < 0.001), and percentage change in tumor size after treatment (p = 0.044), but not between VM and UDM. There was also a significant association between VM and DM with respect to percentage change in tumor size after treatment (p = <0.0001) but not absolute change (p = 0.222). Conclusion: When using simple measurements to assess irregularly shaped nasopharyngeal cancers, the BDM should be used to measure size at diagnosis and the BDM and percentage change in size with treatment. Unidimensional measurement does not reflect size or change in size, and therefore the RECIST criteria may not be applicable to all tumor shapes. The use of DM requires further evaluation

  1. An experimental study on the change of the radiosensitivity of several tumor cell lines and primary cultured gingi cal fibrobrast

    International Nuclear Information System (INIS)

    Lee, Sam Sun; You Dong Soo

    1997-01-01

    Radiation sensitivity data was generated for two human cancer cell lines (KB, RPMI 2650) and human primary gingival fibroblast was tested three times using a viable cell number counting with a hemocytometer, MTT (3-[4,5-dimethylthiazol 2-yl]-2,5-dipheny tetrazolium bromide) assay, and LDH (Lactate dehydrogenase) assay. Single irradiation of 2, 4, 6, 10, 15, 20 Gy were applied to the tumor cell lines and the primary cultured gingical fibroblast. The two fractions of 4 Gy an d 10 Gy were separated with a 4 hour time interval. The irradiation was done with 241.5 cGy/min dose rate using 137 Cs MK cell irradiator at room temperature. The obtained results were as followed : 1. There was significantly different viable cell numbers as the amount of radiation dose on the tested cells were cell number counted with a hemocytometer, In fractions, there were more viable cells remaining. 2. Phase-contrast microscopically, radiation-induced morphologic changes were pronounced on the tumor cells, however, almost no differences on the gingival fibroblast. 3. There was significantly different absorbance at 2 Gy on RPMI 2650, 4 Gy on KB and GF in MTT assay. In fractions, the absorbance was significantly higher on KB. 4. The level of extracellular LDH activity in the experimental group was significantly higher in the 2-4 Gy than the control group. 5. The total level of extracellular and intracellular LDH activity was decreased as increased amounts of radiation dose was applied.

  2. Effects of treatments for experimental bone tumor on prostaglandin E level and bone scintigrams

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Ito, Yasuhiko; Yoneda, Masaya; Muranaka, Akira; Nishishita, Soichi; Morita, Rikushi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1983-10-01

    The role of Prostaglandin E (PgE) level was studied experimentally as follows: 1) intrahepatic implantation of VX-2, 2) intravenous injection of VX-2, 3) effect of treatments on intramedullary implanted VX-2. The levels of PgE in intrahepatic and intravenous transplantation were not higher than that of intramedullary transplantation. Mitomycin C (MMC) did not reduce the PgE level and appearance time of bone scan abnormality was the same as that of untreated animals. A combination of indomethacin and MMC caused a delay in appearance time of bone scan abnormalities.

  3. Magnetic resonance characterization of tumor microvessels in experimental breast tumors using a slow clearance blood pool contrast agent (carboxymethyldextran-A2-Gd-DOTA) with histopathological correlation

    International Nuclear Information System (INIS)

    Preda, Anda; Novikov, Viktor; Moeglich, Martina; Turetschek, Karl; Shames, David M.; Roberts, Timothy P.L.; Brasch, Robert C.; Floyd, Eugenia; Carter, Wayne O.; Corot, Claire

    2005-01-01

    Carboxymethyldextran (CMD)-A2-Gd-DOTA, a slow clearance blood pool contrast agent with a molecular weight of 52.1 kDa, designed to have intravascular residence for more than 1 h, was evaluated for its potential to characterize and differentiate the microvessels of malignant and benign breast tumors. Precontrast single-slice inversion-recovery snapshot FLASH and dynamic contrast-enhanced MRI using an axial T1-weighted three-dimensional spoiled gradient recalled sequence was performed in 30 Sprague-Dawley rats with chemically induced breast tumors. Endothelial transfer coefficient and fractional plasma volume of the breast tumors were estimated from MRI data acquired with CMD-A2-Gd-DOTA enhancement injected at a dose of 0.1 mmol Gd/kg body weight using a two-compartment bidirectional model of the tumor tissue. The correlation between MRI microvessel characteristics and histopathological tumor grade was determined using the Scarff-Bloom-Richardson method. Using CMD-A2-Gd-DOTA, no significant correlations were found between the MR-estimated endothelial transfer coefficient or plasma volumes with histological tumor grade. Analysis of CMD-A2-Gd-DOTA-enhanced MR kinetic data failed to demonstrate feasibility for the differentiation of benign from malignant tumors or for image-based tumor grading. (orig.)

  4. Glucocorticoid treatment of brain tumor patients: changes of apparent diffusion coefficient values measured by MR diffusion imaging

    International Nuclear Information System (INIS)

    Minamikawa, Sosuke; Kono, Kinuko; Nakayama, Keiko; Yokote, Hiroyuki; Tashiro, Takahiko; Inoue, Yuichi; Nishio, Akimasa; Hara, Mitsuhiro

    2004-01-01

    Glucocorticoids (GCC) generally are administered to patients with brain tumors to relieve neurological symptoms by decreasing the water content in a peritumoral zone of edema. We hypothesized that diffusion imaging and apparent diffusion coefficient (ADC) values could detect subtle changes of water content in brain tumors and in peritumoral edema after GCC therapy. The study consisted of 13 patients with intra-axial brain tumor, and ADC was measured in the tumor, within peritumoral edema, and in normal white matter remote from the tumor before and after GCC therapy. ADC also was measured in normal white matter in four control patients with no intracranial disease who were treated with GCC for other indications. Conventional MR images showed no visually evident interval change in tumor size or the extent of peritumoral edema in any subject after GCC therapy, which nonetheless resulted in a decrease in mean ADC of 7.0% in tumors (P 0.05, not significant) and 5.8% in normal white matter (P<0.05). In patients with no intracranial disease, GCC therapy decreased mean ADC in white matter by 5.4% (P<0.05). ADC measurement can demonstrate subtle changes in the brain after GCC therapy that cannot be observed by conventional MR imaging. Measurement of ADC proved to be a sensitive means of assessing the effect of GCC therapy, even in the absence of visually discernible changes in conventional MR images. (orig.)

  5. Evaluation of [1-11C]-α-aminoisobutyric acid for tumor detection and amino acid transport measurement: Spontaneous canine tumor studies

    International Nuclear Information System (INIS)

    Bigler, R.E.; Zanzonico, P.B.; Schmall, B.; Conti, P.S.; Dahl, J.R.; Rothman, L.; Sgouros, G.

    1985-01-01

    Alpha-aminoisobutyric acid (AIB) or α-methyl alanine, is a nonmetabolized amino acid treansported into cells particularly malignant cells, predominantly by the ''A'' amino acid transport system. Since it is not metabolized, [1- 11 C]-AIB can be used to quantify A-type amino acid transport into cells using a relatively simple compartmental model and quantitative imaging procedures (e.g. positron tomography). The tissue distribution of [1- 11 C]-AIB was determined in six dogs bearing spontaneous tumors, including lymphosarcoma, osteogenic sarcoma, mammary carcinoma, and adenocarcinoma. Quantitative imaging with tissue radioassay confirmation at necropsy showed poor to excellent tumor localization. However, in all cases the concentrations achieved appear adequate for amino acid transport measurement at known tumor locations. The observed low normal brain (due to blood-brain barrier exclusion) and high (relative to brain) tumor concentrations of [1- 11 C]-AIB suggest that this agent may prove effective for the early detection of human brain tumors. (orig.)

  6. Hypersonic nozzle/afterbody CFD code validation. I - Experimental measurements

    Science.gov (United States)

    Spaid, Frank W.; Keener, Earl R.

    1993-01-01

    This study was conducted to obtain a detailed experimental description of the flow field created by the interaction of a single-expansion-ramp-nozzle flow with a hypersonic external stream. Data were obtained from a generic nozzle/afterbody model in the 3.5-Foot Hypersonic Wind Tunnel of the NASA Ames Research Center in a cooperative experimental program involving Ames and the McDonnell Douglas Research Laboratories. This paper presents experimental results consisting primarily of surveys obtained with a five-hole total-pressure/flow-direction probe and a total-temperature probe. These surveys were obtained in the flow field created by the interaction between the underexpanded jet plume and the external flow.

  7. Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy

    International Nuclear Information System (INIS)

    Tsunashima, Yoshikazu; Sakae, Takeji; Shioyama, Yoshiyuki; Kagei, Kenji; Terunuma, Toshiyuki; Nohtomi, Akihiro; Akine, Yasuyuki

    2004-01-01

    Purpose: The purpose of this study is to investigate the correlation between the respiratory waveform measured using a respiratory sensor and three-dimensional (3D) tumor motion. Methods and materials: A laser displacement sensor (LDS: KEYENCE LB-300) that measures distance using infrared light was used as the respiratory sensor. This was placed such that the focus was in an area around the patient's navel. When the distance from the LDS to the body surface changes as the patient breathes, the displacement is detected as a respiratory waveform. To obtain the 3D tumor motion, a biplane digital radiography unit was used. For the tumor in the lung, liver, and esophagus of 26 patients, the waveform was compared with the 3D tumor motion. The relationship between the respiratory waveform and the 3D tumor motion was analyzed by means of the Fourier transform and a cross-correlation function. Results: The respiratory waveform cycle agreed with that of the cranial-caudal and dorsal-ventral tumor motion. A phase shift observed between the respiratory waveform and the 3D tumor motion was principally in the range 0.0 to 0.3 s, regardless of the organ being measured, which means that the respiratory waveform does not always express the 3D tumor motion with fidelity. For this reason, the standard deviation of the tumor position in the expiration phase, as indicated by the respiratory waveform, was derived, which should be helpful in suggesting the internal margin required in the case of respiratory gated radiotherapy. Conclusion: Although obtained from only a few breathing cycles for each patient, the correlation between the respiratory waveform and the 3D tumor motion was evident in this study. If this relationship is analyzed carefully and an internal margin is applied, the accuracy and convenience of respiratory gated radiotherapy could be improved by use of the respiratory sensor.Thus, it is expected that this procedure will come into wider use

  8. Experimental infrared measurements for hydrocarbon pollutant determination in subterranean waters

    OpenAIRE

    Lay-Ekuakille, A.; Palamara, I.; Caratelli, D.; Morabito, F.C.

    2013-01-01

    Subterranean waters are often polluted by industrial and anthropic effluents that are drained in subsoil. To prevent and control pollution, legislations of different developed countries require an online monitoring measurement, especially for detecting organic solvents (chlorinated and unchlorinated ones). Online measurements include both real-time and no real-time measurements. In general, it is difficult to implement real-time measurements in stricto sensu for online acquisitions on aqueous...

  9. Computational and Experimental Evaluations of a Novel Thermo-Brachytherapy Seed for Treatment of Solid Tumors

    Science.gov (United States)

    Warrell, Gregory R.

    Hyperthermia has long been known as a radiation therapy sensitizer of high potential; however successful delivery of this modality and integrating it with radiation have often proved technically difficult. We present the dual-modality thermobrachytherapy (TB) seed, based on the ubiquitous low dose-rate (LDR) brachytherapy permanent implant, as a simple and effective combination of hyperthermia and radiation therapy. Heat is generated from a ferromagnetic or ferrimagnetic core within the seed, which produces Joule heating by eddy currents. A strategically-selected Curie temperature provides thermal self-regulation. In order to obtain a uniform and sufficiently high temperature distribution, additional hyperthermia-only (HT-only) seeds are proposed to be used in vacant spots within the needles used to implant the TB seeds; this permits a high seed density without the use of additional needles. Experimental and computational studies were done both to optimize the design of the TB and HT-only seeds and to quantitatively assess their ability to heat and irradiate defined, patient-specific targets. Experiments were performed with seed-sized ferromagnetic samples in tissue-mimicking phantoms heated by an industrial induction heater. The magnetic and thermal properties of the seeds were studied computationally in the finite element analysis (FEA) solver COMSOL Multiphysics, modelling realistic patient-specific seed distributions. These distributions were derived from LDR permanent prostate implants previously conducted at our institution; various modifications of the seeds' design were studied. The calculated temperature distributions were analyzed by generating temperature-volume histograms, which were used to quantify coverage and temperature homogeneity for a range of blood perfusion rates, as well as for a range of seed Curie temperatures and thermal power production rates. The impact of the interseed attenuation and scatter (ISA) effect on radiation dose distributions

  10. Method and timing of tumor volume measurement for outcome prediction in cervical cancer using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mayr, Nina A.; Taoka, Toshiaki; Yuh, William T.C.; Denning, Leah M.; Zhen, Weining K.; Paulino, Arnold C.; Gaston, Robert C.; Sorosky, Joel I.; Meeks, Sanford L.; Walker, Joan L.; Mannel, Robert S.; Buatti, John M.

    2002-01-01

    Purpose: Recently, imaging-based tumor volume before, during, and after radiation therapy (RT) has been shown to predict tumor response in cervical cancer. However, the effectiveness of different methods and timing of imaging-based tumor size assessment have not been investigated. The purpose of this study was to compare the predictive value for treatment outcome derived from simple diameter-based ellipsoid tumor volume measurement using orthogonal diameters (with ellipsoid computation) with that derived from more complex contour tracing/region-of-interest (ROI) analysis 3D tumor volumetry. Methods and Materials: Serial magnetic resonance imaging (MRI) examinations were prospectively performed in 60 patients with advanced cervical cancer (Stages IB 2 -IVB/recurrent) at the start of RT, during early RT (20-25 Gy), mid-RT (45-50 Gy), and at follow-up (1-2 months after RT completion). ROI-based volumetry was derived by tracing the entire tumor region in each MR slice on the computer work station. For the diameter-based surrogate ''ellipsoid volume,'' the three orthogonal diameters (d 1 , d 2 , d 3 ) were measured on film hard copies to calculate volume as an ellipsoid (d 1 x d 2 x d 3 x π/6). Serial tumor volumes and regression rates determined by each method were correlated with local control, disease-free and overall survival, and the results were compared between the two measuring methods. Median post-therapy follow-up was 4.9 years (range, 2.0-8.2 years). Results: The best method and time point of tumor size measurement for the prediction of outcome was the tumor regression rate in the mid-therapy MRI examination (at 45-50 Gy) using 3D ROI volumetry. For the pre-RT measurement both the diameter-based method and ROI volumetry provided similar predictive accuracy, particularly for patients with small ( 3 ) and large (≥100 cm 3 ) pre-RT tumor size. However, the pre-RT tumor size measured by either method had much less predictive value for the intermediate-size (40

  11. In vivo measurement of cell proliferation in canine brain tumor using C-11-labeled FMAU and PET

    International Nuclear Information System (INIS)

    Conti, Peter S.; Bading, James R.; Mouton, Peter P.; Links, Jonathan M.; Alauddin, Mian M.; Fissekis, John D.; Ravert, Hayden T.; Hilton, John; Wong, Dean F.; Anderson, James H.

    2008-01-01

    Introduction: Noncatabolized thymidine analogs are being developed for use in imaging DNA synthesis. We sought to relate a labeling index measured by immunohistochemical staining bromodeoxyuridine (BUdR) technique to the uptake of 11 C 2'-fluoro-5-methyl-1-β-D-arabinofuranosyluracil (FMAU) measured with positron emission tomography (PET) in a brain tumor model. Methods: Adult beagles (n=8) with implanted brain tumors received [ 11 C]FMAU and dynamic imaging with arterial sampling. Six dogs were then infused with BUdR (200 mg/m 2 ) and sacrificed. Tumor time-activity curves (TACs) obtained from computed-tomography-defined regions of interest were corrected for partial volume effects and crosstalk from brain tissue. Tissue was analyzed for the percentage of tumor volume occupied by viable cells and by viable cells in S-phase as identified by BUdR staining. PET/[ 11 C]FMAU and BUdR were compared by linear regression analysis and analysis of variance, as well as by a nonparametric rank correlation test. Results: Tumor standardized uptake values (SUVs) and tumor-to-contralateral-brain uptake ratios at 50 min were 1.6±0.4 and 5.5±1.2 (n=8; mean±S.E.M.), respectively. No 11 C-labeled metabolites were observed in the blood through 60 min. Tumor TACs were well described with a three-compartment/four-parameter model (k 4 =0) and by Patlak analysis. Parametric statistical analysis showed that FMAU clearance from plasma into tumor Compartment 3 (K FMAU ) was significantly correlated with S-phase percent volume (P=.03), while tumor SUV was significantly correlated with both S-phase percent volume and cell percent volume (P=.02 and .03, respectively). Patlak slope, K FMAU and tumor SUV were equivalent with regard to rank correlation analysis, which showed that tumor uptake and trapping of FMAU were correlated with the volume density of dividing cells (P=.0003) rather than nondividing cells (P=.3). Conclusions: Trapping of [ 11 C]FMAU correlated with tumor growth rate, as

  12. Construction of a preclinical multimodality phantom using tissue-mimicking materials for quality assurance in tumor size measurement.

    Science.gov (United States)

    Lee, Yongsook C; Fullerton, Gary D; Goins, Beth A

    2013-07-29

    World Health Organization (WHO) and the Response Evaluation Criteria in Solid Tumors (RECIST) working groups advocated standardized criteria for radiologic assessment of solid tumors in response to anti-tumor drug therapy in the 1980s and 1990s, respectively. WHO criteria measure solid tumors in two-dimensions, whereas RECIST measurements use only one-dimension which is considered to be more reproducible (1, 2, 3,4,5). These criteria have been widely used as the only imaging biomarker approved by the United States Food and Drug Administration (FDA) (6). In order to measure tumor response to anti-tumor drugs on images with accuracy, therefore, a robust quality assurance (QA) procedures and corresponding QA phantom are needed. To address this need, the authors constructed a preclinical multimodality (for ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI)) phantom using tissue-mimicking (TM) materials based on the limited number of target lesions required by RECIST by revising a Gammex US commercial phantom (7). The Appendix in Lee et al. demonstrates the procedures of phantom fabrication (7). In this article, all protocols are introduced in a step-by-step fashion beginning with procedures for preparing the silicone molds for casting tumor-simulating test objects in the phantom, followed by preparation of TM materials for multimodality imaging, and finally construction of the preclinical multimodality QA phantom. The primary purpose of this paper is to provide the protocols to allow anyone interested in independently constructing a phantom for their own projects. QA procedures for tumor size measurement, and RECIST, WHO and volume measurement results of test objects made at multiple institutions using this QA phantom are shown in detail in Lee et al. (8).

  13. Implementation of an Experimental Method for Coupled Subchannel Mixing Measurement

    International Nuclear Information System (INIS)

    Silin, Nicolas; Juanico, Luis; Delmastro, Dario

    2003-01-01

    In this work the application of a thermal tracing technique to the measurement of thermal turbulent mixing between coupled subchannels is presented.The experiment was carried out on a real scale model with geometry similar to nuclear fuel element rod bundles.Thermal mixing rates were measured for water flows at different Reynolds numbers

  14. Performance measurement, expectancy and agency theory: An experimental study

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2008-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. This model implies that, for a given compensation scheme, the agent’s optimal effort is unrelated to the amount of noise in the performance measure. In contrast, expectancy

  15. Experimental device for measuring the dynamic properties of diaphragm motors

    Science.gov (United States)

    Fojtášek, Kamil; Dvořák, Lukáš; Mejzlík, Jan

    The subject of this paper is to design and description of the experimental device for the determination dynamic properties of diaphragm pneumatic motors. These motors are structurally quite different from conventional pneumatic linear cylinders. The working fluid is typically compressed air, the piston of motor is replaced by an elastic part and during the working cycle there is a contact of two elastic environments. In the manufacturers catalogs of these motors are not given any working characteristics. Description of the dynamic behavior of diaphragm motor will be used for verification of mathematical models.

  16. Exploration of two methods for quantitative Mitomycin C measurement in tumor tissue in vitro and in vivo

    DEFF Research Database (Denmark)

    Fischer, Lee MacKenzie; Vásquez, Juan Luis; Gehl, Julie

    2013-01-01

    Two methods of quantifying Mitomycin C in tumor tissue are explored. A method of ultraviolet-visible absorption microscopy is developed and applied to measure the concentration of Mitomycin C in preserved mouse tumor tissue, as well as in gelatin samples. Concentrations as low as 60 μM can...... be resolved using this technique in samples that do not strongly scatter light. A novel method for monitoring the Mitomycin C concentrations inside a tumor is developed, based on microdialysis and ultraviolet-visible spectroscopy. A pump is used to perfuse a microdialysis probe with Ringer’s solution, which...

  17. Calibration of a gamma spectrometer for natural radioactivity measurement. Experimental measurements and Monte Carlo modelling

    International Nuclear Information System (INIS)

    Courtine, Fabien

    2007-03-01

    The thesis proceeded in the context of dating by thermoluminescence. This method requires laboratory measurements of the natural radioactivity. For that purpose, we have been using a germanium spectrometer. To refine the calibration of this one, we modelled it by using a Monte-Carlo computer code: Geant4. We developed a geometrical model which takes into account the presence of inactive zones and zones of poor charge-collection within the germanium crystal. The parameters of the model were adjusted by comparison with experimental results obtained with a source of 137 Cs. It appeared that the form of the inactive zones is less simple than is presented in the specialized literature. This model was widened to the case of a more complex source, with cascade effect and angular correlations between photons: the 60 Co. Lastly, applied to extended sources, it gave correct results and allowed us to validate the simulation of matrix effect. (author)

  18. Analysis of experimental biosensor/FIA lactose measurements

    Directory of Open Access Journals (Sweden)

    Ferreira L.S.

    2003-01-01

    Full Text Available Whey is an abundant effluent in the production of cheese and casein. The biotechnological utilization of this economically important and nutritive source is limited mainly because of the presence of high percentages of lactose. This disaccharide has poor solubility, which can cause crystallization and insufficient sweetness in dairy food; additionally, part of the adult population suffers from associated lactose intolerance diseases. There are several methods to determine lactose such as spectrophotometry, polarimetry, infrared spectroscopy, titrimetry and chromatography. However these methods are tedious and time-consuming due to long sample preparation. These disadvantages stimulated the development of an enzymatic lactose biosensor. It employs two immobilized enzymes, beta-galactosidase and glucose oxidase and the quantitative analysis of lactose is based on determination of oxygen consumption in the enzymatic reaction. The influence of temperature on the biosensor signal was experimentally studied. It was observed that a nonlinear relationship exists between the electric response of the biosensor - provided by CAFCA (Computer Assisted Flow Control & Analysis - ANASYSCON, Hannover - and lactose concentration. In this work, attempts were made to correlate these variables using a simple nonlinear model and multilayered neural networks, with the latter providing the best modeling of the experimental data.

  19. Experimental infrared measurements for hydrocarbon pollutant determination in subterranean waters

    NARCIS (Netherlands)

    Lay-Ekuakille, A.; Palamara, I.; Caratelli, D.; Morabito, F.C.

    2013-01-01

    Subterranean waters are often polluted by industrial and anthropic effluents that are drained in subsoil. To prevent and control pollution, legislations of different developed countries require an online monitoring measurement, especially for detecting organic solvents (chlorinated and unchlorinated

  20. Performance Measurement, Expectancy and Agency Theory: An Experimental Study

    OpenAIRE

    Randolph Sloof; Mirjam van Praag

    2007-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. An important implication of this model is that, for a given compensation scheme, the agent's optimal effort choice is unrelated to the amount of noise in the performance measure. In contrast, expectancy theory as developed by psychologists predicts that effort levels are increasing in the signal-to-noise ratio. We conduct a real effort laboratory experiment to assess the...

  1. Development of experimental methods for measuring fuel elements burnup

    International Nuclear Information System (INIS)

    PEREDA, C; HENRIQUEZ, C; NAVARRO, G; TORRES, H; KLEIN, J; CALDERON, D; MEDEL, J; MUTIS, O; DAIE, J; ITURRIETA, L; LONCOMILLA, M; ZAMBRANO, J; KESTELMAN, A

    2003-01-01

    This paper is a summary of the work carried out during the last two years in fuel burning measurements at RECH-1 for different enrichments, cooling times and burning rates. The measurements were made in two gamma-spectrometric facilities, one is installed in a hot cell and the other inside of the secondary pool of the RECH-1, where the element is under 2 meters of water. The hot cell measurements need at least 100 cooling days because of the problems generated by the transport of highly active fuel elements from the Reactor to the cell. This was the main reason for using the in-pool facility because of its capability to measure the burning of fuel elements without having to wait so long, that is with only 5 cooling days. The accumulated experience in measurements achieved in both facilities and the encouraging results show that this measuring method is reliable. The results agreed well with those obtained using the reactor's physics codes, which was the way they were obtained previously (Cw)

  2. Tumor blood vessel "normalization" improves the therapeutic efficacy of boron neutron capture therapy (BNCT) in experimental oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    D. W. Nigg

    2012-01-01

    We previously demonstrated the efficacy of BNCT mediated by boronophenylalanine (BPA) to treat tumors in a hamster cheek pouch model of oral cancer with no normal tissue radiotoxicity and moderate, albeit reversible, mucositis in precancerous tissue around treated tumors. It is known that boron targeting of the largest possible proportion of tumor cells contributes to the success of BNCT and that tumor blood vessel normalization improves drug delivery to the tumor. Within this context, the aim of the present study was to evaluate the effect of blood vessel normalization on the therapeutic efficacy and potential radiotoxicity of BNCT in the hamster cheek pouch model of oral cancer.

  3. Tumor blood vessel 'normalization' improves the therapeutic efficacy of boron neutron capture therapy (BNCT) in experimental oral cancer

    International Nuclear Information System (INIS)

    Nigg, D.W.

    2012-01-01

    We previously demonstrated the efficacy of BNCT mediated by boronophenylalanine (BPA) to treat tumors in a hamster cheek pouch model of oral cancer with no normal tissue radiotoxicity and moderate, albeit reversible, mucositis in precancerous tissue around treated tumors. It is known that boron targeting of the largest possible proportion of tumor cells contributes to the success of BNCT and that tumor blood vessel normalization improves drug delivery to the tumor. Within this context, the aim of the present study was to evaluate the effect of blood vessel normalization on the therapeutic efficacy and potential radiotoxicity of BNCT in the hamster cheek pouch model of oral cancer.

  4. Diffuse optical measurements of head and neck tumor hemodynamics for early prediction of radiation therapy (Conference Presentation)

    Science.gov (United States)

    Dong, Lixin; Kudrimoti, Mahesh; Irwin, Daniel; Chen, Li; Shang, Yu; Li, Xingzhe; Stevens, Scott D.; Shelton, Brent J.; Yu, Guoqiang

    2016-03-01

    Radiation therapy is a principal modality for head and neck cancers and its efficacy depends on tumor hemodynamics. Our laboratory developed a hybrid diffuse optical instrument allowing for simultaneous measurements of tumor blood flow and oxygenation. In this study, the clinically involved cervical lymph node was monitored by the hybrid instrument once a week over the treatment period of seven weeks. Based on treatment outcomes within one year, patients were classified into a complete response group (CR) and an incomplete response group (IR) with remote metastasis and/or local recurrence. A linear mixed models was used to compare tumor hemodynamic responses to the treatment between the two groups. Interestingly, we found that human papilloma virus (HPV-16) status largely affected tumor hemodynamic responses. For HPV-16 negative tumors, significant differences in blood flow index (BFI, p = 0.007) and reduced scattering coefficient (μs', p = 0.0005) were observed between the two groups; IR tumors exhibited higher μs' values and a continuous increase in BFI over the treatment period. For HPV-16 positive tumors, oxygenated hemoglobin concentration ([HbO2]) and blood oxygen saturation (StO2) were significant different (p = 0.003 and 0.01, respectively); IR group showed lower [HbO2] and StO2. Our results imply HPV-16 negative tumors with higher density of vasculature (μs') and higher blood flow show poor responses to radiotherapy and HPV-16 positive tumors with lower tissue oxygenation level (lower StO2 and [HbO2]) exhibit poor treatment outcomes. Our diffuse optical measurements show the great potential for early prediction of radiotherapy in head and neck cancers.

  5. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue

    International Nuclear Information System (INIS)

    Imanaka, Kazufumi; Tanaka, Koji; Sasai, Keisuke

    1984-01-01

    We have already reported the effectiveness of active specific immunotherapy based on the immune reaction of low-dose irradiated tumor tissue. In the present study, three kinds of immunotherapeutic methods subdivided by used cells were performed in order to compare each effectiveness. C3H/He mice bearing MM 46 tumor transplanted in the right hind paws received local irradiation with the dose of 3,000 rad on the 6th day, and the above-mentioned three methods, using tumor cells, lymphocytes, and tumor cells combining lymphocytes which were all separated from the topical tumor tissue exposed to 2,000 rad, were applied respectively on the 14 th day. The most effective data were obtained from two groups treated by the immunotherapy with tumor cells combining lymphocytes, which virtually caused the longest survival and best tumor growth control. (author)

  6. Design and experimentally measure a high performance metamaterial filter

    Science.gov (United States)

    Xu, Ya-wen; Xu, Jing-cheng

    2018-03-01

    Metamaterial filter is a kind of expecting optoelectronic device. In this paper, a metal/dielectric/metal (M/D/M) structure metamaterial filter is simulated and measured. Simulated results indicate that the perfect impedance matching condition between the metamaterial filter and the free space leads to the transmission band. Measured results show that the proposed metamaterial filter achieves high performance transmission on TM and TE polarization directions. Moreover, the high transmission rate is also can be obtained when the incident angle reaches to 45°. Further measured results show that the transmission band can be expanded through optimizing structural parameters. The central frequency of the transmission band is also can be adjusted through optimizing structural parameters. The physical mechanism behind the central frequency shifted is solved through establishing an equivalent resonant circuit model.

  7. Experimental nonlocality-based randomness generation with nonprojective measurements

    Science.gov (United States)

    Gómez, S.; Mattar, A.; Gómez, E. S.; Cavalcanti, D.; Farías, O. Jiménez; Acín, A.; Lima, G.

    2018-04-01

    We report on an optical setup generating more than one bit of randomness from one entangled bit (i.e., a maximally entangled state of two qubits). The amount of randomness is certified through the observation of Bell nonlocal correlations. To attain this result we implemented a high-purity entanglement source and a nonprojective three-outcome measurement. Our implementation achieves a gain of 27% of randomness as compared with the standard methods using projective measurements. Additionally, we estimate the amount of randomness certified in a one-sided device-independent scenario, through the observation of Einstein-Podolsky-Rosen steering. Our results prove that nonprojective quantum measurements allow extending the limits for nonlocality-based certified randomness generation using current technology.

  8. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (2). Combination effect on MM102 syngeneic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Tsuchiya, Yoshiharu; Niitsu, Iwayasu; Hayashibara, Hiromi; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-03-01

    C3H/He mice transplanted syngeneic MM102 tumor subcutaneously in the footpad were used to study the timing of administration of lentinan when combined with local irradiation of X-ray. In combination with 1,000 rads irradiation, the administration of lentinan after X-ray was not effective. When lentinan was administered in combination with 2,000 to 3,000 rads irradiation, the growth of tumor was decreased significantly in comparison with the groups which received radiotherapy alone and those that received lentinan alone. The administration of lentinan before irradiation was effective at the same degree in the group that received lentinan after irradiation. Life prolongation effect was also observed in the group that received lentinan before and after irradiation, and 4 mice among 8 tested mice were survived at 70th day after tumor transplantation.

  9. Performance measurement, expectancy and agency theory: An experimental study

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2005-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. An important implication of this model is that, for a given compensation scheme, the agent's optimal effort choice is unrelated to the amount of noise in the performance

  10. Transgenic expression of soluble human CD5 enhances experimentally-induced autoimmune and anti-tumoral immune responses.

    Directory of Open Access Journals (Sweden)

    Rafael Fenutría

    Full Text Available CD5 is a lymphoid-specific transmembrane glycoprotein constitutively expressed on thymocytes and mature T and B1a lymphocytes. Current data support the view that CD5 is a negative regulator of antigen-specific receptor-mediated signaling in these cells, and that this would likely be achieved through interaction with CD5 ligand/s (CD5L of still undefined nature expressed on immune or accessory cells. To determine the functional consequence of loss of CD5/CD5L interaction in vivo, a new transgenic mouse line was generated (shCD5EμTg, expressing a circulating soluble form of human CD5 (shCD5 as a decoy to impair membrane-bound CD5 function. These shCD5EμTg mice showed an enhanced response to autologous antigens, as deduced from the presentation of more severe forms of experimentally inducible autoimmune disease (collagen-induced arthritis, CIA; and experimental autoimmune encephalitis, EAE, as well as an increased anti-tumoral response in non-orthotopic cancer models (B16 melanoma. This enhancement of the immune response was in agreement with the finding of significantly reduced proportions of spleen and lymph node Treg cells (CD4+CD25+FoxP3+, and of peritoneal IL-10-producing and CD5+ B cells, as well as an increased proportion of spleen NKT cells in shCD5EμTg mice. Similar changes in lymphocyte subpopulations were observed in wild-type mice following repeated administration of exogenous recombinant shCD5 protein. These data reveal the relevant role played by CD5/CD5L interactions on the homeostasis of some functionally relevant lymphocyte subpopulations and the modulation of immune responses to autologous antigens.

  11. Radioimmunotherapy with an antibody to HPV16 E6 oncoprotein is effective in experimental cervical tumor expressing low levels of E6

    Science.gov (United States)

    Jiang, Zewei; Wang, Xing Guo; Einstein, Mark H; Goldberg, Gary L; Casadevall, Arturo

    2010-01-01

    Purpose HPV16 is associated with ∼50% of all cervical cancers worldwide. The E6 and E7 genes of oncogenic HPV types, such as HPV16, are necessary for the HPV transforming function and tumorogenesis making them ideal targets for novel treatments. Radioimmunotherapy employs systemically administered radiolabeled monoclonal antibodies (mAbs) that bind to tumor-associated antigens. Previously we demonstrated in mice that radioimmunotherapy targeting viral antigens with mAb to HPV16 E6 suppressed CasKi cervical tumors expressing high levels of E6 (∼600 copies of HPV per cell). However, that study opened the question whether radioimmunotherapy can suppress the growth of cervical tumors with low E6 and E7 expression, such as may be seen in patients. Experimental Design We evaluated the expression of E6 in patients' tumors and in the SiHa cell line expressing low levels of E6 and E7 (1–2 copies of HPV per cell) and found them comparable. We initiated SiHa tumors in nude mice, radiolabeled C1P5 mAb to E6 with a beta-emitter 188-Rhenium (188Re) and treated tumor-bearing mice with: (1) 200 µCi 188Re-C1P5 alone; (2) proteasome inhibitor MG132 alone; (3) MG132 followed by 200 µCi 188Re-C1P5; (4) unlabeled C1P5; (5) 200 µCi 188Re-18B7 (isotype-matching control mAb); (6) no treatment. 188Re-C1P5 alone and in combination with MG-132 significantly retarded tumor growth compared to all control groups. Conclusions Our data demonstrate the possibility to suppress tumor growth by targeting viral antigens even in cervical tumors with low E6 expression and provide additional evidence for the potential usefulness of radioimmunotherapy targeting HPV-related antigens in the clinic. PMID:20861673

  12. In vivo evidence for a functional role of both tumor necrosis factor (TNF) receptors and transmembrane TNF in experimental hepatitis.

    Science.gov (United States)

    Küsters, S; Tiegs, G; Alexopoulou, L; Pasparakis, M; Douni, E; Künstle, G; Bluethmann, H; Wendel, A; Pfizenmaier, K; Kollias, G; Grell, M

    1997-11-01

    The significance of tumor necrosis factor receptor 1 (TNFR1) for TNF function in vivo is well documented, whereas the role of TNFR2 so far remains obscure. In a model of concanavalin A (Con A)-induced, CD4+ T cell-dependent experimental hepatitis in mice, in which TNF is a central mediator of apoptotic and necrotic liver damage, we now provide evidence for an essential in vivo function of TNFR2 in this pathophysiological process. We demonstrate that a cooperation of TNFR1 and TNFR2 is required for hepatotoxicity as mice deficient of either receptor were resistant against Con A. A significant role of TNFR2 for Con A-induced hepatitis is also shown by the enhanced sensitivity of transgenic mice overexpressing the human TNFR2. The ligand for cytotoxic signaling via both TNF receptors is the precursor of soluble TNF, i.e. transmembrane TNF. Indeed, transmembrane TNF is sufficient to mediate hepatic damage, as transgenic mice deficient in wild-type soluble TNF but expressing a mutated nonsecretable form of TNF developed inflammatory liver disease.

  13. The combination of IL-21 and IFN-alpha boosts STAT3 activation, cytotoxicity and experimental tumor therapy

    DEFF Research Database (Denmark)

    Eriksen, Karsten W; Søndergaard, Henrik; Woetmann, Anders

    2008-01-01

    such as IFN-alpha and IL-2 have multiple and severe side effects. Accordingly, they are generally used at sub-optimal doses, which limit their clinical efficacy. Here we hypothesized that a combination of IFN-alpha and IL-21, a novel cytokine of the IL-2 family with anti-cancer effects, will increase the anti......-cancer efficacy at sub-optimal cytokine doses. We show that the combined stimulation of target-cells with IFN-alpha and IL-21 triggers an increased STAT3 activation whereas the activation of other STATs including STAT1/2 is unaffected. In parallel, the combined stimulation with IFN-alpha and IL-21 triggers...... a selective increase in MHC class I expression and NK- and CD8(+) T-cell-mediated cytotoxicity. In an experimental in vivo model of renal carcinoma, the combined treatment of IFN-alpha and IL-21 also produces a significant anti-cancer effect as judged by an inhibition of tumor growth and an increased survival...

  14. Increased pulmonary secretion of tumor necrosis factor-alpha in calves experimentally infected with bovine respiratory syncytial virus

    DEFF Research Database (Denmark)

    Rontved, C. M.; Tjørnehøj, Kirsten; Viuff, B.

    2000-01-01

    , of which 23 were experimentally infected with BRSV and five were given a mock inoculum. The presence of the cytokine tumor necrosis factor alpha (TNF-alpha) in the BAL fluids was detected and quantified by a capture ELISA. TNF-alpha was detected in 21 of the infected animals. The amount of TNF-alpha...... in the BAL fluid of calves killed post inoculation day (PID) 2 and 4 was at the same very low level as in the uninfected control animals. Large amounts of TNF-alpha were detected on PID 6, maximum levels of TNF-alpha were reached on PID 7, and smaller amounts of TNF-alpha were seen on PID 8. The high levels...... of TNF-alpha appeared on the days where severe lung lesions and clinical signs were obvious and the amounts of BRSV-antigen were at their greatest. Although Pasteurellaceae were isolated from some of the BRSV-infected calves, calves treated with antibiotics before and through the whole period...

  15. "Calibration" system for spectral measurements and its experimental results

    Science.gov (United States)

    Bruchkouskaya, Sviatlana I.; Katkovsky, Leonid V.; Belyaev, Boris I.; Malyshev, Vladislav B.

    2017-04-01

    "Calibration" system has been developed at A. N. Sevchenko Research Institute of Applied Physical Problems of the Belarusian State University. It was designed for measuring the characteristics of spectral reflectance of all types of natural surfaces (test sites) in ground conditions or on board of aircraft carriers and has the following components: - Photospectroradiometr (PhSR) of high resolution with a range of 400-900 nm, equipped with a digital time-lapse video system; - Two-channel modular spectroradiometer (TMS) with a range of 400-900 nm, designed for simultaneous measurements of reflected light brightness of the underlying surface and the incident radiation from the upper hemisphere; - Two portable spectroradiometers (PSR-700 and PSR-1300) with a spectral range 800-1500 nm; 1200-2500 nm; - Scanning solar spectropolarimeter (SSP-600) with a range of 350-950 nm for measurements of direct sunlight and scattered by the atmosphere at different angles; "Calibration" system provides spectral resolution of 5.2 nm in a range of 400-900 nm, 10 nm in a range of 800-1500 nm and 15 nm in a range of 1200-2500 nm. Measurements of the optical characteristics of solar radiation (for determining parameters of the atmosphere) and that of underlying surface are synchronous. There is also a set of special nozzles for measurements of spectral brightness coefficients, polarization characteristics and spectral albedo. Spectra and images are geotagged to the navigation data (time, GPS). For the measurements of spectral reflection dependencies within "Monitoring-SG" framework expeditions to the Kuril Islands, Kursk aerospace test site and Kamchatka Peninsula were conducted in 2015 and 2016. The spectra of different underlying surfaces have been obtained: soils, plants and water objects, sedimentary and volcanic rocks. These surveys are a valuable material for further researches and selection of test facilities for flight calibration of space imaging systems. Information obtained

  16. Experimental viscosity measurements of biodiesels at high pressure

    Directory of Open Access Journals (Sweden)

    Schaschke C.J.

    2016-01-01

    Full Text Available The viscosity of biodiesels of soybean and rapeseed biodiesels blended with mineral diesel fuel were measured at pressures of up to 200 MPa. Using a falling sinker-type viscometer reproducible viscosity data were obtained based on the time taken for a sinker to descend a fixed distance down an enclosed tube under the influence of gravity. Measurements were taken using pressures which correspond to those of interest in automotive common rail diesel engines, and at temperatures of between 25ºC and 80ºC. In all cases, the viscosity of the biodiesel blends were found to increase exponentially for which the blends were noted as being more viscous than pure mineral fuels. A pressure-freezing effect was not observed for the blends.

  17. Experimental approaches to the measurement of dielectronic recombination

    International Nuclear Information System (INIS)

    Datz, S.

    1984-01-01

    In dielectronic recombination, the first step involves a continuum electron which excites a previously bound electron and, in so doing, loses just enough energy to be captured in a bound state (nl). This results in a doubly excited ion of a lower charge state which may either autoionize or emit a photon resulting in a stabilized recombination. The complete signature of the event is an ion of reduced charge and an emitted photon. Methods of measuring this event are discussed

  18. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  19. In vivo relaxation time measurements on a murine tumor model--prolongation of T1 after photodynamic therapy.

    Science.gov (United States)

    Liu, Y H; Hawk, R M; Ramaprasad, S

    1995-01-01

    RIF tumors implanted on mice feet were investigated for changes in relaxation times (T1 and T2) after photodynamic therapy (PDT). Photodynamic therapy was performed using Photofrin II as the photosensitizer and laser light at 630 nm. A home-built proton solenoid coil in the balanced configuration was used to accommodate the tumors, and the relaxation times were measured before, immediately after, and up to several hours after therapy. Several control experiments were performed untreated tumors, tumors treated with Photofrin II alone, or tumors treated with laser light alone. Significant increases in T1s of water protons were observed after PDT treatment. In all experiments, 31P spectra were recorded before and after the therapy to study the tumor status and to confirm the onset of PDT. These studies show significant prolongation of T1s after the PDT treatment. The spin-spin relaxation measurements, on the other hand, did not show such prolongation in T2 values after PDT treatment.

  20. Experimental measurement of electron heat diffusivity in a tokamak

    International Nuclear Information System (INIS)

    Callen, J.D.; Jahns, G.L.

    1976-06-01

    The electron temperature perturbation produced by internal disruptions in the center of the Oak Ridge Tokamak (ORMAK) is followed with a multi-chord soft x-ray detector array. The space-time evolution is found to be diffusive in character, with a conduction coefficient larger by a factor of 2.5 - 15 than that implied by the energy containment time, apparently because it is a measurement for the small group of electrons whose energies exceed the cut-off energy of the detectors

  1. Self-protection of FLIP fuel: Experimental measurements

    International Nuclear Information System (INIS)

    Johnson, A.G.; Ringle, J.C.; Anderson, T.V.; Dodd, B.; Bennett, S.; Carpenter, W.T.

    1980-01-01

    During the last year and one-half non-power reactor licensees of the Nuclear Regulatory Commission (NRC) have been repeatedly alerted to the fact that the Commission planned to tighten physical security regulations for their class of reactors. Essentially all of the new NRC physical security requirements for these reactors have been based on the type, quantity and enrichment of the special nuclear materials (e.g. enriched uranium and plutonium) possessed by the licensees. While each licensee's security classification will be evaluated individually, it is now apparent that non-power reactor licensees using or storing formula quantities of special nuclear material not meeting the 100 rem per hour at three feet self-protection exemption (e.g. 5 kilograms or more of non-self-protected fuel enriched to 20% or more with U-235) will be required to meet extremely stringent NRC physical security requirements patterned after the new Physical Protection Upgrade Rule. Implementation of these much stricter security requirements poses many economic and operational difficulties for university research reactors, to the point where facility closure could be the only alternative. TRIGA reactors utilizing a full FLIP fueled core, such as the Oregon State University TRIGA (OSTR), qualify for the highest physical protection category unless fuel can be maintained at self-protecting radiation levels. In order to demonstrate that OSTR fuel could be consistently kept above the 100 rem per hour threshold, a computer program was written which predicts the gamma radiation levels from an irradiated FLIP fuel element at 1, 2 and 3 feet in air and water. Furthermore, in order to verify the accuracy of the computer program, actual measurements of irradiated fuel elements were made at 3 feet in air and at 1, 2 and 3 feet in water, and the results compared very favorably to the predictions. The results of specific measurements, the instrumentation used and its calibration, the personnel doses

  2. A review of direct experimental measurements of detachment

    Science.gov (United States)

    Boedo, J.; McLean, A. G.; Rudakov, D. L.; Watkins, J. G.

    2018-04-01

    Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. We review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson scattering in the divertor region and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.

  3. Tumor immunology

    International Nuclear Information System (INIS)

    Otter, W. den

    1987-01-01

    Tumor immunology, the use of immunological techniques for tumor diagnosis and approaches to immunotherapy of cancer are topics covered in this multi-author volume. Part A, 'Tumor Immunology', deals with present views on tumor-associated antigens, the initiation of immune reactions of tumor cells, effector cell killing, tumor cells and suppression of antitumor immunity, and one chapter dealing with the application of mathematical models in tumor immunology. Part B, 'Tumor Diagnosis and Imaging', concerns the use of markers to locate the tumor in vivo, for the histological diagnosis, and for the monitoring of tumor growth. In Part C, 'Immunotherapy', various experimental approaches to immunotherapy are described, such as the use of monoclonal antibodies to target drugs, the use of interleukin-2 and the use of drugs inhibiting suppression. In the final section, the evaluation, a pathologist and a clinician evaluate the possibilities and limitations of tumor immunology and the extent to which it is useful for diagnosis and therapy. refs.; figs.; tabs

  4. Boron neutron capture therapy (BNCT) inhibits tumor development from precancerous tissue: An experimental study that supports a potential new application of BNCT

    International Nuclear Information System (INIS)

    Monti Hughes, A.; Heber, E.M.; Pozzi, E.; Nigg, D.W.; Calzetta, O.; Blaumann, H.; Longhino, J.; Nievas, S.I.; Aromando, R.F.; Itoiz, M.E.; Trivillin, V.A.; Schwint, A.E.

    2009-01-01

    We previously demonstrated the efficacy of boron neutron capture therapy (BNCT) mediated by boronophenylalanine (BPA), GB-10 (Na 2 10 B 10 H 10 ) and (GB-10+BPA) to control tumors, with no normal tissue radiotoxicity, in the hamster cheek pouch oral cancer model. Herein we developed a novel experimental model of field-cancerization and precancerous lesions (globally termed herein precancerous tissue) in the hamster cheek pouch to explore the long-term potential inhibitory effect of the same BNCT protocols on the development of second primary tumors from precancerous tissue. Clinically, second primary tumor recurrences occur in field-cancerized tissue, causing therapeutic failure. We performed boron biodistribution studies followed by in vivo BNCT studies, with 8 months follow-up. All 3 BNCT protocols induced a statistically significant reduction in tumor development from precancerous tissue, reaching a maximum inhibition of 77-100%. The inhibitory effect of BPA-BNCT and (GB-10+BPA)-BNCT persisted at 51% at the end of follow-up (8 months), whereas for GB-10-BNCT it faded after 2 months. Likewise, beam-only elicited a significant but transient reduction in tumor development. No normal tissue radiotoxicity was observed. At 8 months post-treatment with BPA-BNCT or (GB-10+BPA)-BNCT, the precancerous pouches that did not develop tumors had regained the macroscopic and histological appearance of normal (non-cancerized) pouches. A potential new clinical application of BNCT would lie in its capacity to inhibit local regional recurrences.

  5. Experimental ion mobility measurements in Xe-CF4 mixtures

    Science.gov (United States)

    Cortez, A. F. V.; Kaja, M. A.; Escada, J.; Santos, M. A. G.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2018-04-01

    In this paper we present the results of the ion mobility measurements made in gaseous mixtures of xenon with carbon tetrafluoride (Xe-CF4) for pressures ranging from 6 to 10 Torr (8-10.6 mbar) and for low reduced electric fields in the 10 to 25 Td range (2.4-6.1 kVṡcm‑1ṡbar‑1), at room temperature. The time-of-arrival spectra revealed one or two peaks depending on the gas relative abundances, which were attributed to CF3+ and to Xe2+ ions. However, for Xe concentrations above 60%, only one peak remains (Xe2+). The reduced mobilities obtained from the peak centroid of the time-of-arrival spectra are presented for Xe concentrations in the 5%-95% range.

  6. Isotopic Resonance Hypothesis: Experimental Verification by Escherichia coli Growth Measurements

    Science.gov (United States)

    Xie, Xueshu; Zubarev, Roman A.

    2015-03-01

    Isotopic composition of reactants affects the rates of chemical and biochemical reactions. As a rule, enrichment of heavy stable isotopes leads to progressively slower reactions. But the recent isotopic resonance hypothesis suggests that the dependence of the reaction rate upon the enrichment degree is not monotonous. Instead, at some ``resonance'' isotopic compositions, the kinetics increases, while at ``off-resonance'' compositions the same reactions progress slower. To test the predictions of this hypothesis for the elements C, H, N and O, we designed a precise (standard error +/-0.05%) experiment that measures the parameters of bacterial growth in minimal media with varying isotopic composition. A number of predicted resonance conditions were tested, with significant enhancements in kinetics discovered at these conditions. The combined statistics extremely strongly supports the validity of the isotopic resonance phenomenon (p biotechnology, medicine, chemistry and other areas.

  7. Overview of the In-Flight Experimentations and Measurements on the IXV Experimental Vehicle

    Science.gov (United States)

    Cosson, E.; Giusto, S.; Del Vecchio, A.; Mancuso, S.

    2009-01-01

    After an assessment and then a trade-off of all the passenger experiments proposed by different partners within Europe, a selection of Core Experiments to be embarked on-board IXV to fulfil the Mission and System Requirements has been made. Some Passenger Experiments have also been identified to be potentially embarked, provided it is compatible with the system allocations, since they could bring valuable additional in-flight data. All those experiments include Thermal Protection System (TPS) experiments (including innovative TPS materials), AeroThermoDynamic (ATD) experiments and Health Monitoring System (HMS) experiments. Aside the previously mentioned experiments, a specific Vehicle Model Identification experiment (VMI) aims at validating in-flight the mathematical models of flight dynamics for a gliding re-entry vehicle. This paper also presents a preliminary version of the in- flight measurement plan, encompassing both conventional instrumentation and advanced sensors or even innovative measurement techniques.

  8. Tumor control induced by Boron Neutron Capture Therapy (BNCT) as a function of dose in an experimental model of liver metastases at 5 weeks follow-up

    International Nuclear Information System (INIS)

    Pozzi, E C C; Trivillin, V A; Colombo, L L; Monti Hughes, A; Thorp, S; Cardoso, J E; Garabalino, M A; Molinari, A J; Heber, E M; Curotto, Paula; Miller, M; Itoiz, M E; Aromando, R F; Nigg, D W; Schwint, A E

    2012-01-01

    BNCT has been proposed for the treatment of multifocal, non-resectable, bilobar colorectal liver metastases that do not respond to chemotherapy. We recently reported that BNCT mediated by boronophenylalanine (BPA) induced significant remission of experimental colorectal tumor nodules in rat liver at 3 weeks follow-up with no contributory liver toxicity (Pozzi et al.,2012). The aim of the present study was to evaluate tumor control and potential liver toxicity of BPA-BNCT at 5 weeks follow-up. Prescribed dose was retrospectively evaluated based on blood boron values, allowing for assessment of response over a range of delivered dose values (author)

  9. Comparison of Lumipulse® G1200 with Kryptor and Modular E170 for the measurement of 7 tumor markers

    OpenAIRE

    Marlet , Julien; Bernard , Maguy

    2014-01-01

    "This is the pre-peer reviewed version of the following article: "Comparison of LUMIPULSE® G1200 With Kryptor and Modular E170 for the Measurement of Seven Tumor Markers", which has been published in final form at http://onlinelibrary.wiley.com/doi/10.1002/jcla.21802/abstract. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving."; Background: Tumor marker measurements are becoming essential for prognosis and follow-up of patien...

  10. Dynamic {sup 11}C-methionine PET analysis has an additional value for differentiating malignant tumors from granulomas: an experimental study using small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Songji; Zhao, Yan [Hokkaido University, Department of Nuclear Medicine, Graduate School of Medicine, Sapporo (Japan); Hokkaido University, Department of Tracer Kinetics and Bioanalysis, Graduate School of Medicine, Sapporo (Japan); Kuge, Yuji; Hatano, Toshiyuki [Hokkaido University, Central Institute of Isotope Science, Sapporo (Japan); Yi, Min; Kohanawa, Masashi [Hokkaido University, Department of Advanced Medicine, Graduate School of Medicine, Sapporo (Japan); Magota, Keiichi; Tamaki, Nagara [Hokkaido University, Department of Nuclear Medicine, Graduate School of Medicine, Sapporo (Japan); Nishijima, Ken-ichi [Hokkaido University, Department of Molecular Imaging, Graduate School of Medicine, Sapporo (Japan)

    2011-10-15

    We evaluated whether the dynamic profile of L-{sup 11}C-methionine ({sup 11}C-MET) may have an additional value in differentiating malignant tumors from granulomas in experimental rat models by small animal positron emission tomography (PET). Rhodococcus aurantiacus and allogenic rat C6 glioma cells were inoculated, respectively, into the right and left calf muscles to generate a rat model bearing both granulomas and tumors (n = 6). Ten days after the inoculations, dynamic {sup 11}C-MET PET was performed by small animal PET up to 120 min after injection of {sup 11}C-MET. The next day, after overnight fasting, the rats were injected with {sup 18}F-2-deoxy-2-fluoro-D-glucose ({sup 18}F-FDG), and dynamic {sup 18}F-FDG PET was performed up to 180 min. The time-activity curves, static images, and mean standardized uptake value (SUV) in the lesions were calculated. {sup 11}C-MET uptake in the granuloma showed a slow exponential clearance after an initial distribution, while the uptake in the tumor gradually increased with time. The dynamic pattern of {sup 11}C-MET uptake in the granuloma was significantly different from that in the tumor (p < 0.001). In the static analysis of {sup 11}C-MET, visual assessment and SUV analysis could not differentiate the tumor from the granuloma in all cases, although the mean SUV in the granuloma (1.48 {+-} 0.09) was significantly lower than that in the tumor (1.72 {+-} 0.18, p < 0.01). The dynamic patterns, static images, and mean SUVs of {sup 18}F-FDG in the granuloma were similar to those in the tumor (p = NS). Dynamic {sup 11}C-MET PET has an additional value for differentiating malignant tumors from granulomatous lesions, which deserves further elucidation in clinical settings. (orig.)

  11. Dynamic 11C-methionine PET analysis has an additional value for differentiating malignant tumors from granulomas: an experimental study using small animal PET

    International Nuclear Information System (INIS)

    Zhao, Songji; Zhao, Yan; Kuge, Yuji; Hatano, Toshiyuki; Yi, Min; Kohanawa, Masashi; Magota, Keiichi; Tamaki, Nagara; Nishijima, Ken-ichi

    2011-01-01

    We evaluated whether the dynamic profile of L- 11 C-methionine ( 11 C-MET) may have an additional value in differentiating malignant tumors from granulomas in experimental rat models by small animal positron emission tomography (PET). Rhodococcus aurantiacus and allogenic rat C6 glioma cells were inoculated, respectively, into the right and left calf muscles to generate a rat model bearing both granulomas and tumors (n = 6). Ten days after the inoculations, dynamic 11 C-MET PET was performed by small animal PET up to 120 min after injection of 11 C-MET. The next day, after overnight fasting, the rats were injected with 18 F-2-deoxy-2-fluoro-D-glucose ( 18 F-FDG), and dynamic 18 F-FDG PET was performed up to 180 min. The time-activity curves, static images, and mean standardized uptake value (SUV) in the lesions were calculated. 11 C-MET uptake in the granuloma showed a slow exponential clearance after an initial distribution, while the uptake in the tumor gradually increased with time. The dynamic pattern of 11 C-MET uptake in the granuloma was significantly different from that in the tumor (p 11 C-MET, visual assessment and SUV analysis could not differentiate the tumor from the granuloma in all cases, although the mean SUV in the granuloma (1.48 ± 0.09) was significantly lower than that in the tumor (1.72 ± 0.18, p 18 F-FDG in the granuloma were similar to those in the tumor (p = NS). Dynamic 11 C-MET PET has an additional value for differentiating malignant tumors from granulomatous lesions, which deserves further elucidation in clinical settings. (orig.)

  12. Removal of Arsenic with Oyster Shell: Experimental Measurements

    Directory of Open Access Journals (Sweden)

    Md. Atiqur Rahman, , and

    2008-12-01

    Full Text Available Oyster shell has tremendous potential as a remediation material for the removal of arsenic from groundwater. A single arsenic removal system was developed with oyster shell for tube well water containing arsenic. The system removes arsenic from water by adsorption through fine oyster shell. Various conditions that affect the adsorption/desorption of arsenic were investigated. Adsorption column methods showed the removal of As(III under the following conditions: initial As concentration, 100 µg /L; oyster shell amount, 6 g; particle size, <355µm ; treatment flow rate, 1.7 mL/min; and pH 6.5. Arsenic concentration of the treated water were below the Bangladesh drinking water standard of 50 µg/L for As. The desorption efficiencies with 2M of KOH after the treatment of groundwater were in the range of 80-83%. A combination of techniques was used to measure the pH, conductivity, cations and anions. The average concentrations of other inorganic constituents of health concern (Na, K, Ca, Mg and Fe in treated water were below their respective WHO guideline for drinking. The present study might provide new avenues to achieve the arsenic concentrations required for drinking water recommended by Bangladesh and the World Health Organization (WHO.

  13. Research in radiobiology: Final report of work in progress in immunobiology of experimental host-tumor relationships

    Energy Technology Data Exchange (ETDEWEB)

    1993-03-15

    Our work on the immunobiology of tumors induced in normal mice by non-ionizing radiation and chemical carcinogens has previously demonstrated a correlation between MHC molecule expression and the immunogenicity of tumors in a transplanted syngeneic host. Such that immunogenic or regressive tumors were found to demonstrate higher constitutive or inducible levels of MHC expression, while most virulent, aggressive tumors exhibited a low level of MHC Class I expression. We attributed much of the control of MHC molecule expression by antigen-bearing tumors and normal cells to the immunological status of the host since the host must provide the appropriate stimulus to enhance MHC antigen expression by the invading tumor. Our results with UVR-induced tumors suggested that a significant role is played by the T-cell lymphokine, {gamma}-interferon ({gamma}IFN), in the modulation of MHC molecule expression in vivo. Virulent tumors, induced by boneseeking radionuclides, may be refractory to {gamma}IFN stimulation of MHC molecule expression. It is also possible that certain tumors might be fully responsive to the Class I modulatory influences by {gamma}IFN, but exhibit a reduced capacity to stimulate the synthesis of this lymphokine by host T cells. We present experiments designed to : Describe the virulence, latency period, and transplantation characteristics of {sup 238}PU, {sup 24l}Am, and {sup 228}Th tumors arising as osteogenic sarcomas and hepatic carcinomas, to determine the relationship between inducible expression of MHC Class I molecules by {gamma}IFN and in vivo immunogenicity of these radioisotype-induced tumors, and to elucidate any molecular mechanisms responsible for a lack of responsiveness to a {gamma}IFN failure by the host to induce host {gamma}IFN production.

  14. Research in radiobiology: Final report of work in progress in immunobiology of experimental host-tumor relationships

    Energy Technology Data Exchange (ETDEWEB)

    1993-03-15

    Our work on the immunobiology of tumors induced in normal mice by non-ionizing radiation and chemical carcinogens has previously demonstrated a correlation between MHC molecule expression and the immunogenicity of tumors in a transplanted syngeneic host. Such that immunogenic or regressive tumors were found to demonstrate higher constitutive or inducible levels of MHC expression, while most virulent, aggressive tumors exhibited a low level of MHC Class I expression. We attributed much of the control of MHC molecule expression by antigen-bearing tumors and normal cells to the immunological status of the host since the host must provide the appropriate stimulus to enhance MHC antigen expression by the invading tumor. Our results with UVR-induced tumors suggested that a significant role is played by the T-cell lymphokine, [gamma]-interferon ([gamma]IFN), in the modulation of MHC molecule expression in vivo. Virulent tumors, induced by boneseeking radionuclides, may be refractory to [gamma]IFN stimulation of MHC molecule expression. It is also possible that certain tumors might be fully responsive to the Class I modulatory influences by [gamma]IFN, but exhibit a reduced capacity to stimulate the synthesis of this lymphokine by host T cells. We present experiments designed to : Describe the virulence, latency period, and transplantation characteristics of [sup 238]PU, [sup 24l]Am, and [sup 228]Th tumors arising as osteogenic sarcomas and hepatic carcinomas, to determine the relationship between inducible expression of MHC Class I molecules by [gamma]IFN and in vivo immunogenicity of these radioisotype-induced tumors, and to elucidate any molecular mechanisms responsible for a lack of responsiveness to a [gamma]IFN failure by the host to induce host [gamma]IFN production.

  15. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (3). Combination effect on the metastatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Niitsu, Iwayasu; Hayashibara, Hiromi; Tsuchiya, Yoshiharu; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-03-01

    Combination effect of lentinan with X-ray irradiation on the metastatic mouse tumors, L1210, KLN205 and Lewis lung carcinoma were studied. Combination use of lentinan with X-ray therapy prolonged the life of BDF/sub 1/ mice bearing L1210 leukemia in the suitable combination conditions. Combination effects of lentinan with X-ray therapy were also observed on the suppression of the growth of KLN205 squamus cell carcinoma and on the suppression of the metastasis of Lewis lung carcinoma. Especially, in the case that lentinan was administered before or after X-ray local irradiation in the pulmorary metastasis system of Lewis lung carcinoma, a marked suppressin of pulmonary metastasis was observed and 2 to 4 mice among 8 tested mice were tumor free.

  16. Cell kinetics of irradiated experimental tumors: cell transition from the non-proliferating to the proliferating pool

    International Nuclear Information System (INIS)

    Potmesil, M.; Goldfeder, A.

    1980-01-01

    In murine mammary carcinomas, parenchymal tumor cells with dense nucleoli traverse the cell cycle and divide, thus constituting the proliferating pool. Cells with trabeculate or ring-shaped nucleoli either proceed slowly through G 1 phase or are arrested in it. The role of these non-proliferating, G 1 phase-confined cells in tumor regeneration was studied in vivo after a subcurative dose of X-irradiation in two transplantable tumor lines. Tumor-bearing mice were continuously injected with methyl[ 3 H]thymidine before and after irradiation. Finally, the labeling was discontinued, mice injected with vincristine sulfate and cells arrested in metaphase were accumulated over 10-hrs. Two clearly delineated groups of vincristine-arrested mitoses emerged in autoradiograms prepared from tumor tissue at the time of starting tumor regrowth: one group with the silver-grain counts corresponding to the background level, the other with heavily labeled mitoses. As the only source of unlabeled mitoses was unlabeled G 1 phase-confined cells persisting in the tumor, this indicated cell transition from the non-proliferating to the proliferating pool, which took place in the initial phase of the tumor regrowth. Unlabeled progenitors have apparently remained in G 1 phase for at least 5-12 days after irradiation. (author)

  17. Diverse bone morphogenetic protein expression profiles and smad pathway activation in different phenotypes of experimental canine mammary tumors.

    Directory of Open Access Journals (Sweden)

    Helena Wensman

    Full Text Available BACKGROUND: BMPs are currently receiving attention for their role in tumorigenesis and tumor progression. Currently, most BMP expression studies are performed on carcinomas, and not much is known about the situation in sarcomas. METHODOLOGY/PRINCIPAL FINDINGS: We have investigated the BMP expression profiles and Smad activation in clones from different spontaneous canine mammary tumors. Spindle cell tumor and osteosarcoma clones expressed high levels of BMPs, in particular BMP-2, -4 and -6. Clones from a scirrhous carcinoma expressed much lower BMP levels. The various clones formed different tumor types in nude mice but only clones that expressed high levels of BMP-6 gave bone formation. Phosphorylated Smad-1/5, located in the nucleus, was detected in tumors derived from clones expressing high levels of BMPs, indicating an active BMP signaling pathway and BMP-2 stimulation of mammary tumor cell clones in vitro resulted in activation of the Smad-1/5 pathway. In contrast BMP-2 stimulation did not induce phosphorylation of the non-Smad pathway p38 MAPK. Interestingly, an increased level of the BMP-antagonist chordin-like 1 was detected after BMP stimulation of non-bone forming clones. CONCLUSIONS/SIGNIFICANCE: We conclude that the specific BMP expression repertoire differs substantially between different types of mammary tumors and that BMP-6 expression most probably has a biological role in bone formation of canine mammary tumors.

  18. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 7

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Maeda, Tomoho; Yoshida, Shoji; Yamamoto, Yoichi; Morita, Masaru

    1983-01-01

    We have already reported the remarkable effect of the active specific immunotherapy utilizing cryopreserved tumor cells and infiltrating mononuclear cells prepared from a lowdose irradiated tumor tissue after cytoreductive radiotherapy. In the present study, the effect of a biological response modifier, PSK combined with this active specific immunotherapy was investigated. Twelve-week-aged female C3H/He mice transplanted with MM46 tumor cells were received local radiotherapy with the dose of 3,000 rads by high energy electron beam on the fifth day after tumor inoculation. This active specific immunotherapy was performed on the twelveth day, and daily dose of 200 mg/kg of PSK was injected intraperitoneally from the sixth day to the tenth day. The more inhibition of the tumor growth was observed in the group which received this active specific immunotherapy combined with a biological response modifier, PSK compared with that received this active specific immunotherapy alone. (author)

  19. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  20. Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements

    Directory of Open Access Journals (Sweden)

    Daniele Tosi

    2015-01-01

    Full Text Available Radiofrequency thermal ablation (RFA is a procedure aimed at interventional cancer care and is applied to the treatment of small- and midsize tumors in lung, kidney, liver, and other tissues. RFA generates a selective high-temperature field in the tissue; temperature values and their persistency are directly related to the mortality rate of tumor cells. Temperature measurement in up to 3–5 points, using electrical thermocouples, belongs to the present clinical practice of RFA and is the foundation of a physical model of the ablation process. Fiber-optic sensors allow extending the detection of biophysical parameters to a vast plurality of sensing points, using miniature and noninvasive technologies that do not alter the RFA pattern. This work addresses the methodology for optical measurement of temperature distribution and pressure using four different fiber-optic technologies: fiber Bragg gratings (FBGs, linearly chirped FBGs (LCFBGs, Rayleigh scattering-based distributed temperature system (DTS, and extrinsic Fabry-Perot interferometry (EFPI. For each instrument, methodology for ex vivo sensing, as well as experimental results, is reported, leading to the application of fiber-optic technologies in vivo. The possibility of using a fiber-optic sensor network, in conjunction with a suitable ablation device, can enable smart ablation procedure whereas ablation parameters are dynamically changed.

  1. Validity of bioluminescence measurements for noninvasive in vivo imaging of tumor load in small animals

    NARCIS (Netherlands)

    Klerk, Clara P. W.; Overmeer, Renée M.; Niers, Tatjana M. H.; Versteeg, Henri H.; Richel, Dick J.; Buckle, Tessa; van Noorden, Cornelis J. F.; van Tellingen, Olaf

    2007-01-01

    A relatively new strategy to longitudinally monitor tumor load in intact animals and the effects of therapy is noninvasive bioluminescence imaging (BLI). The validity of BLI for quantitative assessment of tumor load in small animals is critically evaluated in the present review. Cancer cells are

  2. Sensitivity of fibroblast growth factor 23 measurements in tumor-induced osteomalacia

    DEFF Research Database (Denmark)

    Imel, Erik A; Peacock, Munro; Pitukcheewanont, Pisit

    2006-01-01

    Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome of hypophosphatemia, decreased renal phosphate reabsorption, normal or low serum 1,25-dihydryxyvitamin-D concentration, myopathy, and osteomalacia. Fibroblast growth factor 23 (FGF23) is a phosphaturic protein overexpressed in tumors t...

  3. Reproducibility of O-(2-{sup 18}F-fluoroethyl)-L-tyrosine uptake kinetics in brain tumors and influence of corticoid therapy: an experimental study in rat gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Stegmayr, Carina; Schoeneck, Michael; Oliveira, Dennis; Willuweit, Antje [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); Filss, Christian; Coenen, Heinz H.; Langen, Karl-Josef [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Aachen, Department of Nuclear Medicine and Neurology, Aachen (Germany); Galldiks, Norbert [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); Shah, N. Jon [Institute of Neuroscience and Medicine, Research Center Juelich, Juelich (Germany); University of Aachen, Department of Nuclear Medicine and Neurology, Aachen (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Juelich (Germany)

    2016-06-15

    Positron emission tomography (PET) using O-(2-{sup 18}F-fluoroethyl)-L-tyrosine ({sup 18}F-FET) is a well-established method for the diagnostics of brain tumors. This study investigates reproducibility of {sup 18}F-FET uptake kinetics in rat gliomas and the influence of the frequently used dexamethasone (Dex) therapy. F98 glioma or 9L gliosarcoma cells were implanted into the striatum of 31 Fischer rats. After 10-11 days of tumor growth, the animals underwent dynamic PET after injection of {sup 18}F-FET (baseline). Thereafter, animals were divided into a control group and a group receiving Dex injections, and all animals were reinvestigated 2 days later. Tumor-to-brain ratios (TBR) of {sup 18}F-FET uptake (18-61 min p.i.) and the slope of the time-activity-curves (TAC) (18-61 min p.i.) were evaluated using a Volume-of-Interest (VOI) analysis. Data were analyzed by two-way repeated measures ANOVA and reproducibility by the intraclass correlation coefficient (ICC). The slope of the tumor TACs showed high reproducibility with an ICC of 0.93. A systematic increase of the TBR in the repeated scans was noted (3.7 ± 2.8 %; p < 0.01), and appeared to be related to tumor growth as indicated by a significant correlation of TBR and tumor volume (r = 0.77; p < 0.0001). After correction for tumor growth TBR showed high longitudinal stability with an ICC of 0.84. Dex treatment induced a significant decrease of the TBR (-8.2 ± 6.1 %; p < 0.03), but did not influence the slope of the tumor TAC. TBR of {sup 18}F-FET uptake and tracer kinetics in brain tumors showed high longitudinal stability. Dex therapy may induce a minor decrease of the TBR; this needs further investigation. (orig.)

  4. Experimental Measurement of the Flow Field of Heavy Trucks

    Energy Technology Data Exchange (ETDEWEB)

    Fred Browand; Charles Radovich

    2005-05-31

    trucks in a tandem configuration. In December 2003, such fuel consumption tests were performed at the same Crows Landing testsite. In the tests, two identical trucks are operated at headways in the range 3-10 meters. The trucks are steered by hand, but longitudinal control is provided by a closed-loop control system. Laser ranging measures truck-to-truck distance, and the control system maintains a truck separation to within about {+-} 3 centimeters. From these tests it is concluded that both trucks save fuel by close-following, that the fuel saving increases with decreasing spacing, and that the trail truck saves more fuel. An average value of fuel saving for each of the two trucks at spacings of 6-10 meters can be taken to be 3.0 liters/100 km.

  5. Use of 99mTc-HYNIC-βAla-Bombesina(7-14) peptide for the identification of prostate tumor, LNCaP line, in an experimental model

    International Nuclear Information System (INIS)

    Fuscaldi, Leonardo Lima

    2012-01-01

    Prostate cancer is one of the most prevalent tumors in men, showing high mortality rates. Current diagnostic methods are not able to identify early prostate carcinoma, often resulting in a late diagnosis with established metastasis. Thus, there is by the scientific community an incessant search for diagnostic methods for early assessment of prostate cancer, facilitating the treatment and increasing the chances of cure. In this context, nuclear medicine provides a diagnostic method which can detect tumors at an early stage, because it is based on biochemical and physiological changes of the tissue, such as overexpression of gastrin releasing peptide receptors (GRPr's) by prostate cancer cells. Bombesin, a tetradecapeptide isolated from the frog Bombina bombina, has a high affinity for the GRPr's, since it is analogous to gastrin releasing peptide. Therefore, this study aims to prepare the complex 99m Tc-HYNIC-βAla-Bombesina (7-14) and use it for the identification of prostate tumor, LNCaP line, in an experimental model. For in vitro assays, aliquots of 0.026 MBq of the radiopeptide were incubated with 2x10 6 LNCaP cells in a water bath at 37 deg C, for 1 and 4 hours, with and without prior addition of cold peptide (n=3). Prostate tumors were induced into the upper right flank of male BALB/c nude mice by subcutaneous injection of 5x106 LNCaP cells resuspended in 150 μL of Matrigel:RPMI-1640 medium (1:1). Biodistribution profile (n=5) and scintigraphic images (n=3) were obtained at 1 and 4 hours after intravenous injection of 7.4 MBq of 99m Tc-HYNIC-βAla-Bombesina (7-14) . To assess this, healthy male BALB/c mice and tumor-bearing male BALB/c nude mice with 15, 20 and 25 days of tumor development were used. In vitro study results showed that the fraction of the radiopeptide which bound to LNCaP cells was 2.08 +- 0.30% (1 hour) and 2.44 +- 0.18% (4 hours). From the percentage which was bound, the internalized fractions were 25.64 +- 3.14% (1 hour) and 25.27 +- 2

  6. Effects of tumor necrosis factor alpha antagonist, platelet activating factor antagonist, and nitric oxide synthase inhibitor on experimental otitis media with effusion.

    Science.gov (United States)

    Kim, Dong-Hyun; Park, Yong-Soo; Jeon, Eun-Ju; Yeo, Sang-Won; Chang, Ki-Hong; Lee, Seung Kyun

    2006-08-01

    We studied the inflammatory responses in otitis media with effusion induced by lipopolysaccharide (LPS) in rats, and compared the preventive effects of tumor necrosis factor (TNF) soluble receptor type I (sTNFRI, a TNF-alpha antagonist), platelet activating factor antagonist, and the nitric oxide synthase inhibitor N(G)-nitro-L-arginine methyl ester (L-NAME). We used 2 control groups of Sprague Dawley rats (untreated and saline-treated) and 4 experimental groups, which all received an intratympanic injection of LPS, followed in 3 groups by experimental treatment of the same ear. The LPS group had no additional treatment. The L-NAME group received intraperitoneal injection of L-NAME and was reinjected after 12 hours. The A-85783 group was first given an intraperitoneal injection of A-85783. The sTNFRI group was first given an intratympanic injection of sTNFRI. Twenty-four hours after the initial intratympanic injection of LPS, temporal bones from each group were examined histopathologically and the vascular permeability of the middle ear mucosa was measured by Evans blue vital dye staining. The L-NAME, A-85783, and sTNFRI groups showed significantly reduced capillary permeability, subepithelial edema, and infiltration of inflammatory cells in comparison with the LPS group. There were no differences in capillary permeability, subepithelial edema, or infiltration of inflammatory cells between the A-85783 and sTNFRI groups. The L-NAME group showed no difference in vascular permeability or subepithelial edema in comparison with the A-85783 and sTNFRI groups, but showed more infiltration of inflammatory cells. We conclude that sTNFRI, A-85783, and L-NAME can be proposed as alternative future treatments for otitis media with effusion. However, L-NAME may be the least effective of these agents.

  7. Evaluation of response to hormone therapy in patients with measurable adult granulosa cell tumors of the ovary

    NARCIS (Netherlands)

    van Meurs, Hannah S.; van der Velden, Jacobus; Buist, Marrije R.; van Driel, Willemien J.; Kenter, Gemma G.; van Lonkhuijzen, Luc R. C. W.

    2015-01-01

    The aim of this study was to retrospectively determine the objective response rate to hormone therapy (HT) for patients with a measurable adult granulosa cell tumor (GCT) of the ovary in a consecutive series of patients. All patients with an adult GCT who were treated with HT [steroidal progestins,

  8. A biomimetic tumor tissue phantom for validating diffusion-weighted MRI measurements.

    Science.gov (United States)

    McHugh, Damien J; Zhou, Feng-Lei; Wimpenny, Ian; Poologasundarampillai, Gowsihan; Naish, Josephine H; Hubbard Cristinacce, Penny L; Parker, Geoffrey J M

    2018-07-01

    To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion-weighted (DW) MRI measurements. Coaxial-electrospraying was used to generate micron-sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW-MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron-CT as well as SEM and MR scans. ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm 2 /ms (Δ = 12 ms) and 1.20 ± 0.05 µm 2 /ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom. A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW-MRI-derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147-158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is

  9. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 5

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Imanaka, Kazufumi; Gose, Kyuhei; Imajo, Yoshinari; Kimura, Shuji

    1982-01-01

    We have already reported the remarkable effect of the active specific immunotherapy utilizing cryopreserved tumor cells and infiltrating mononuclear cells prepared from a low-dose irradiated tumor tissue after cytoreductive radiotherapy. In the present study, the effect of a biological response modifier, OK-432 combined with this active specific immunotherapy was investigated. Twelve-week-aged female C3H/He mice transplanted with MM46 tumor cells were received local radiotherapy with the dose of 3,000 rads by high energy electron beam on the sixth day after inoculation. This active specific immunotherapy was performed on the thirteenth day, and daily dose of 1.0 KE of OK-432 was injected intraperitoneally from the thirteenth day to the seventeenth day. The inhibition of the tumor growth was observed in the group which received this active specific immunotherapy combined with a biological response modifier, OK-432 compared with that received this active specific immunotherapy alone. (author)

  10. Effect of titanium dental implants on proton therapy delivered for head tumors: experimental validation using an anthropomorphic head phantom

    Science.gov (United States)

    Oancea, C.; Shipulin, K.; Mytsin, G.; Molokanov, A.; Niculae, D.; Ambrožová, I.; Davídková, M.

    2017-03-01

    A dosimetric experiment was performed at the Medico-Technical Complex in the Joint Institute for Nuclear Research, Dubna, to investigate the effects of metallic dental implants in the treatment of head and neck tumours with proton therapy. The goal of the study was to evaluate the 2D dose distributions of different clinical treatment plans measured in an anthropomorphic phantom, and compare them to predictions from a treatment planning system. The anthropomorphic phantom was sliced into horizontal segments. Two grade 4 Titanium implants were inserted between 2 slices, corresponding to a maxillary area. GafChromic EBT2 films were placed between the segments containing the implants to measure the 2D delivered dose. Two different targets were designed: the first target includes the dental implants in the isocentre, and in the second target, the proton beam is delivered through the implants, which are located at the entrance region of the Bragg curve. The experimental results were compared to the treatment plans made using our custom 3D Treatment Planning System, named RayTreat. To quantitatively determine differences in the isodose distributions (measured and calculated), the gamma index (3 mm, 3%) was calculated for each target for the matrix value in the region of high isodose (> 90%): for the experimental setup, which includes the implants in the SOBP region, the result obtained was 84.3%. When the implants were localised in the entrance region of the Bragg curve, the result obtained was 86.4%. In conclusion, the uncertainties introduced by the clinically planned dose distribution are beyond reasonable limits. The linear energy transfer spectra in close proximity to the implants were investigated using solid state nuclear track detectors (TED). Scattered particles outside the target were detected.

  11. Effect of titanium dental implants on proton therapy delivered for head tumors: experimental validation using an anthropomorphic head phantom

    International Nuclear Information System (INIS)

    Oancea, C.; Shipulin, K.; Mytsin, G.; Molokanov, A.; Niculae, D.; Ambrožová, I.; Davídková, M.

    2017-01-01

    A dosimetric experiment was performed at the Medico-Technical Complex in the Joint Institute for Nuclear Research, Dubna, to investigate the effects of metallic dental implants in the treatment of head and neck tumours with proton therapy. The goal of the study was to evaluate the 2D dose distributions of different clinical treatment plans measured in an anthropomorphic phantom, and compare them to predictions from a treatment planning system. The anthropomorphic phantom was sliced into horizontal segments. Two grade 4 Titanium implants were inserted between 2 slices, corresponding to a maxillary area. GafChromic EBT2 films were placed between the segments containing the implants to measure the 2D delivered dose. Two different targets were designed: the first target includes the dental implants in the isocentre, and in the second target, the proton beam is delivered through the implants, which are located at the entrance region of the Bragg curve. The experimental results were compared to the treatment plans made using our custom 3D Treatment Planning System, named RayTreat. To quantitatively determine differences in the isodose distributions (measured and calculated), the gamma index (3 mm, 3%) was calculated for each target for the matrix value in the region of high isodose (> 90%): for the experimental setup, which includes the implants in the SOBP region, the result obtained was 84.3%. When the implants were localised in the entrance region of the Bragg curve, the result obtained was 86.4%. In conclusion, the uncertainties introduced by the clinically planned dose distribution are beyond reasonable limits. The linear energy transfer spectra in close proximity to the implants were investigated using solid state nuclear track detectors (TED). Scattered particles outside the target were detected.

  12. The preparation for an instant kit of 99mTc(V) DMSA as a tumor-seeking imaging agent and animal experimentation

    International Nuclear Information System (INIS)

    Li Yunlong; Li Hongyu; Jing Hui; Guo Hongyuan; Liu Yingmei; Zhao Hui

    1997-10-01

    A method for preparing an instant kit of 99m Tc(V) DMSA was described. The effect of pH on labelling efficiency of the kit was investigated. 99m Tc(V) DMSA was characterized by TLC on silica-gel sheets, eluting with n-butanol: acetic acid: water = 3:2:3 (volume ratio). Radiochemical purity and stability of 99m Tc(V) DMSA in vitro were studied. The results clearly demonstrated that the yield of 99m Tc(V) DMSA was more than 95% at pH 8∼8.5 and the agent was stable in 3 h at room temperature. Effect of temperature, moisture and luminosity on the stability of the freeze-dried kit were considered. The biological distributions of 99m Tc(V) DMSA were measured in mice bearing tumor S180. The results indicated that during 1∼6 h after i.v. injection, 99m Tc(V) DMSA was highly up taken in tumor tissue, the ratios of tumor: muscle and tumor: bone were in the ranges of 1.4∼2.4 and 1.2∼1.8, respectively. This peculiarity indicated that 99m Tc(V) DMSA has tumor-seeking property and could be used as a tumor-seeking imaging agent. (9 refs., 11 tabs.)

  13. Experimental validation of error in temperature measurements in thin walled ductile iron castings

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2007-01-01

    An experimental analysis has been performed to validate the measurement error of cooling curves measured in thin walled ductile cast iron. Specially designed thermocouples with Ø0.2 mm thermocouple wire in Ø1.6 mm ceramic tube was used for the experiments. Temperatures were measured in plates...

  14. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 8

    International Nuclear Information System (INIS)

    Imanaka, Kazufumi; Gose, Kyuhei; Ichiyanagi, Akihiro

    1983-01-01

    The effectiveness of active specific immunotherapy prepared from a low-dose irradiated tumor tissue has already reported. The present study was designed to investigate the effect of Mitomycin C-treated active specific immunotherapy. Twelve-week-aged female C3H/He mice transplanted with MM 46 tumors were exposed to local electron radiotherapy with a dose of 3,000 rad on the 5th day after tumor inoculation. Tumor cells prepared for active specific immunotherapy were pretreated with Mitomycin C at concentration of 20 μg/10 7 cells in Eagle MEM Earle containing 100 IU/ml penicillin. The cell suspension was incubated at 37 0 C for 15 minutes. Mitomycin C-treated active specific immunotherapy was performed on the 12th day. Antitumor effect was evaluated by the regression of the tumor and survival curve. The remarkable regression of the tumor and significant elongation of the survival period were observed in the group which received Mitomycin C-treated active specific immunotherapy and the group which received active specific immunotherapy without the treatment of Mitomycin C. (author)

  15. Experimental study of a swept reflectometer with a single antenna for plasma density profile measurement

    International Nuclear Information System (INIS)

    Calderon, M.A.G.; Simonet, F.

    1984-12-01

    The feasibility of a swept microwave reflectometer, with one antenna only, for plasma electron density measurement is studied. Experimental results obtained in the laboratory by simulating the plasma with a metallic mirror are presented

  16. Experimental device for the X-ray energetic distribution measurement in a tokamak plasma

    International Nuclear Information System (INIS)

    Perez-Navarro, A.

    1977-01-01

    An experimental system to measure the X-ray spectrum in a tokamak plasma is described, emphasizing its characteristics: resolution, dead time and the pulse pile-up distortion effects on the X-ray spectra. (author) [es

  17. Measuring the apparent diffusion coefficient in primary rectal tumors: is there a benefit in performing histogram analyses?

    Science.gov (United States)

    van Heeswijk, Miriam M; Lambregts, Doenja M J; Maas, Monique; Lahaye, Max J; Ayas, Z; Slenter, Jos M G M; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H

    2017-06-01

    The apparent diffusion coefficient (ADC) is a potential prognostic imaging marker in rectal cancer. Typically, mean ADC values are used, derived from precise manual whole-volume tumor delineations by experts. The aim was first to explore whether non-precise circular delineation combined with histogram analysis can be a less cumbersome alternative to acquire similar ADC measurements and second to explore whether histogram analyses provide additional prognostic information. Thirty-seven patients who underwent a primary staging MRI including diffusion-weighted imaging (DWI; b0, 25, 50, 100, 500, 1000; 1.5 T) were included. Volumes-of-interest (VOIs) were drawn on b1000-DWI: (a) precise delineation, manually tracing tumor boundaries (2 expert readers), and (b) non-precise delineation, drawing circular VOIs with a wide margin around the tumor (2 non-experts). Mean ADC and histogram metrics (mean, min, max, median, SD, skewness, kurtosis, 5th-95th percentiles) were derived from the VOIs and delineation time was recorded. Measurements were compared between the two methods and correlated with prognostic outcome parameters. Median delineation time reduced from 47-165 s (precise) to 21-43 s (non-precise). The 45th percentile of the non-precise delineation showed the best correlation with the mean ADC from the precise delineation as the reference standard (ICC 0.71-0.75). None of the mean ADC or histogram parameters showed significant prognostic value; only the total tumor volume (VOI) was significantly larger in patients with positive clinical N stage and mesorectal fascia involvement. When performing non-precise tumor delineation, histogram analysis (in specific 45th ADC percentile) may be used as an alternative to obtain similar ADC values as with precise whole tumor delineation. Histogram analyses are not beneficial to obtain additional prognostic information.

  18. Comparison of LUMIPULSE(®) G1200 With Kryptor and Modular E170 for the Measurement of Seven Tumor Markers.

    Science.gov (United States)

    Marlet, Julien; Bernard, Maguy

    2016-01-01

    Tumor marker measurements are becoming essential for prognosis and follow-up of patients in oncology. In this context, we aimed to compare a new analyzer, Lumipulse(®) G1200 (Fujirebio group, distributed in Europe by the Innogenetics group) with Kryptor(®) (Thermo Fisher Scientific B.R.A.H.M.S, Asnières, France) and Modular(®) Elecsys E170 (Roche Diagnostics, Meylan, France) for the measurement of seven tumor markers: PSA, AFP, CEA, CA 15-3, CA 125, CA 19-9, and Cyfra 21-1. A total of 471 serum samples from patients with elevated tumor markers and 100 serum from healthy patients were analyzed with Lumipulse(®) G1200 and either Kryptor(®) (for AFP) or Modular(®) (for the six other markers). The good precision of Lumipulse(®) G1200 assays was confirmed with CVs Lumipulse results were well correlated with Modular or Kryptor results (r ≥ 0.94). Concordance of results interpretation was > 95% and tumor marker kinetics were all similar. We confirmed the analytical performances of Lumipulse(®) tumor marker assays except for the CYFRA 21-1 assay for which performances were poor in this study. We noticed a few discrepancies for the CEA assay. Besides, values obtained for CA 19-9 were higher with Lumipulse leading to a bias (slope = 1.5). But for the four other tumor markers assays (PSA, AFP, CA 125, CA 15-3), the results were directly transferable between Lumipulse and Kryptor or Modular, thus facilitating an eventual substitution of one system by another. © 2014 Wiley Periodicals, Inc.

  19. The correlation between the rise of the tumor temperature during the hyperthermia treatment and the tumor blood flow measured by dynamic CT and 15O gas-positron emission tomography

    International Nuclear Information System (INIS)

    Hattori, Hideyuki

    1993-01-01

    This study was designed to determine the correlation between the rise of tumor temperature during hyperthermia treatment and the blood flow of the tumors measured by dynamic CT (DCT) and 15 O gas-positron emission tomography. In this report, we observed 20 patients with malignant tumors which underwent hyperthermia treatment. In each case, the temperature of the tumor was monitored with a photofiber sensor. DCT's and 15 O gas-positron emission tomographies were applied before the hyperthermia treatment. During the DCT, the tumor blood flow of each tumor was estimated by analyzing the time-dependent activity curve after a bolus injection. During the 15 O gas-positron emission tomography, the tumor blood flow was estimated by the C 15 O 2 -steady-state method. The value of the tumor blood flow estimated by DCT were proportional to those calculated by the 15 O gas-positron emission tomography. These values were inversely proportional to the rise of the temperature of the tumors during hyperthermia treatment. Our results imply that DCT as well as the 15 O gas-positron emission tomography can be used for the prediction of the tumor temperature rise during the hyperthermia treatment. (author)

  20. Experimental study of the correlation between 99Tcm-EC-MNZ SPECT imaging and the expression of hypoxia inducible factor-1α in tumor tissuse

    International Nuclear Information System (INIS)

    Chen Jie; Lu Xueguan; Tang Jun; Fan Wo

    2005-01-01

    Objective: To evaluate the correlation between 99 Tc m -ethylene dicysteinc-metronidazaole ( 99 Tc M -EC-MNZ) SPECT imaging and the expression of hypoxia inducible factor-1α (HIF-1α) in tumor tissue. Methods: Twelve S180 sarcoma-bearing Kunming mice tumor models were established. Hypoxic imaging was obtained by SPECT with 99 Tc m -EC-MNZ and the corresponding tumor/muscle ratios (T/M) were measured. Then the animals were sacrificed and the tumor specimen was resected, the expression of HIF-1α and vascular endothelial growth factor (VEGF) was measured by immunohistochemistry. Results: Three hours after injection of 99 Tc m -EC-MNZ, the T/M ranged from 1.93 to 4.46 (median 3.13). The expression of HIF-1α ranged from 31.2% to 60.8% (median 50.4%) and was linearly correlated with the T/M (t=2.732, r=0.654, P=0.021). The expression of VEGF ranged from 33.8% to 57.5% (median 53.1%) and also linearly correlated with the expression of HIF-1α (t=3.011, r=0.690, P=0.0131). Conclusions: There is linear correlation between 99 Tc m -EC-MNZ hypoxic SPECT imaging and the expression of HIF-1α. Combining them can reliably reflect the hypoxic status of the tumor. (authors)

  1. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  2. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  3. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  4. Theoretical background and experimental measurements of human brain noise intensity in perception of ambiguous images

    International Nuclear Information System (INIS)

    Runnova, Anastasiya E.; Hramov, Alexander E.; Grubov, Vadim V.; Koronovskii, Alexey A.; Kurovskaya, Maria K.; Pisarchik, Alexander N.

    2016-01-01

    We propose a theoretical approach associated with an experimental technique to quantitatively characterize cognitive brain activity in the perception of ambiguous images. Based on the developed theoretical background and the obtained experimental data, we introduce the concept of effective noise intensity characterizing cognitive brain activity and propose the experimental technique for its measurement. The developed theory, using the methods of statistical physics, provides a solid experimentally approved basis for further understanding of brain functionality. The rather simple way to measure the proposed quantitative characteristic of the brain activity related to the interpretation of ambiguous images will hopefully become a powerful tool for physicists, physiologists and medics. Our theoretical and experimental findings are in excellent agreement with each other.

  5. LOFT experimental measurements uncertainty analyses. Volume XX. Fluid-velocity measurement using pulsed-neutron activation

    International Nuclear Information System (INIS)

    Lassahn, G.D.; Taylor, D.J.N.

    1982-08-01

    Analyses of uncertainty components inherent in pulsed-neutron-activation (PNA) measurements in general and the Loss-of-Fluid-Test (LOFT) system in particular are given. Due to the LOFT system's unique conditions, previously-used techniques were modified to make the volocity measurement. These methods render a useful, cost-effective measurement with an estimated uncertainty of 11% of reading

  6. Boron neutron capture therapy (BNCT) inhibits tumor development from precancerous tissue: An experimental study that supports a potential new application of BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Monti Hughes, A.; Heber, E.M. [Department of Radiobiology, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina); Pozzi, E. [Department of Radiobiology, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina); Department of Research and Production Reactors, Ezeiza Atomic Center, CNEA, Buenos Aires (Argentina); Nigg, D.W. [Idaho National Laboratory, Idaho Falls, Idaho (United States); Calzetta, O.; Blaumann, H.; Longhino, J. [Department of Nuclear Engineering, Bariloche Atomic Center, CNEA, Rio Negro (Argentina); Nievas, S.I. [Department of Chemistry, CNEA, Buenos Aires (Argentina); Aromando, R.F. [Department of Oral Pathology, Faculty of Dentistry, University of Buenos Aires, Buenos Aires (Argentina); Itoiz, M.E. [Department of Radiobiology, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina); Department of Oral Pathology, Faculty of Dentistry, University of Buenos Aires, Buenos Aires (Argentina); Trivillin, V.A. [Department of Radiobiology, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina); Schwint, A.E. [Department of Radiobiology, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina)], E-mail: schwint@cnea.gov.ar

    2009-07-15

    We previously demonstrated the efficacy of boron neutron capture therapy (BNCT) mediated by boronophenylalanine (BPA), GB-10 (Na{sub 2}{sup 10}B{sub 10}H{sub 10}) and (GB-10+BPA) to control tumors, with no normal tissue radiotoxicity, in the hamster cheek pouch oral cancer model. Herein we developed a novel experimental model of field-cancerization and precancerous lesions (globally termed herein precancerous tissue) in the hamster cheek pouch to explore the long-term potential inhibitory effect of the same BNCT protocols on the development of second primary tumors from precancerous tissue. Clinically, second primary tumor recurrences occur in field-cancerized tissue, causing therapeutic failure. We performed boron biodistribution studies followed by in vivo BNCT studies, with 8 months follow-up. All 3 BNCT protocols induced a statistically significant reduction in tumor development from precancerous tissue, reaching a maximum inhibition of 77-100%. The inhibitory effect of BPA-BNCT and (GB-10+BPA)-BNCT persisted at 51% at the end of follow-up (8 months), whereas for GB-10-BNCT it faded after 2 months. Likewise, beam-only elicited a significant but transient reduction in tumor development. No normal tissue radiotoxicity was observed. At 8 months post-treatment with BPA-BNCT or (GB-10+BPA)-BNCT, the precancerous pouches that did not develop tumors had regained the macroscopic and histological appearance of normal (non-cancerized) pouches. A potential new clinical application of BNCT would lie in its capacity to inhibit local regional recurrences.

  7. Experimental research of 99Tcm-MIBI SPECT in detecting multidrug resistance status on tumor nude mice

    International Nuclear Information System (INIS)

    Hu Xudong; Ji Cheng; Wang Xiaoyue; Xu Jiaying; Fan Saijun; Yang Guoren

    2009-01-01

    Objective: To analyze 99 Tc m -MIBI images separately before and after VPL in nude mice bearing human lung tumors in order to find a feasible way in evaluating MDR status of tumor with 99 Tc m -MIBI image. Methods: Analysis of 99 Tc m -MIBI images was performed at 15 min, 60 min and 120 min after injecting 99 Tc m -MIBI 7.4 MBq in female BALB/c nude mice bearing human lung tumors. The tumor uptake rate (TUR) and retention rate (RI) were calculated and the data were analyzed. P-gp albumen ex-pression was determined by flow cytometry. Results: Significance difference in TUR was observed for at the 15th, 60th or 120th min between the imaging in the control group versus in the second imaging in VPL reverse group as well as between the first imaging and the second imaging in the reverse group. Furthermore, there was negative correlation between retention rate (RI) and P-gp albumen expression. Conclusion: These results for the first time demonstrate that the results of 99 Tc m -MIBI imaging exhibits a negative correlation to P-gp albumen expression, indicating that analysis of 99 Tc m -MIBI imaging may be a potential indicator for MDR status of tumor and can be used to monitoring the role of VPL in reverting the multidrug resistance. (authors)

  8. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 9

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Maeda, Tomoho; Yoshida, Shoji

    1983-01-01

    We have already reported the remarkable effect of an active specific immunotherapy using cryopreserved tumor cells and infiltrating mononuclear cells prepared from a low-dose irradiated tumor tissue after cytoreductive radiotherapy. In the present study, the effect of a biological response modifier, OK-432 combined with the active specific immunotherapy was investigated. Twelve-week-aged female C3H/He mice transplanted with MM 46 tumor cells were received local radiotherapy with a dose of 3,000 rads by high energy electron beams on the fifth day after inoculation. The tumor cells and infiltrating mononuclear cells cryopreserved for two months were thawed and treated with mitomycin-C at concentration of 20 μg/10 7 cells at 37 0 C for 30 min. Then, these cells were injected subcutaneously into the left hind paws as a mitomycin C-treated, cryopreserved active specific immunotherapy on the thirteenth day, and daily dose of 1 KE of OK-432 was injected intraperitoneally from the sixth to the tenth days. The inhibition of the tumor growth was similarly observed in the group which received this active specific immunotherapy combined with a biological response modifier, OK-432. (author)

  9. Tumor size measured by preoperative ultrasonography and postoperative pathologic examination in papillary thyroid carcinoma: relative differences according to size, calcification and coexisting thyroiditis.

    Science.gov (United States)

    Yoon, Young Hoon; Kwon, Ki Ryun; Kwak, Seo Young; Ryu, Kyeung A; Choi, Bobae; Kim, Jin-Man; Koo, Bon Seok

    2014-05-01

    Ultrasonography (US) is a useful diagnostic modality for evaluation of the size and features of thyroid nodules. Tumor size is a key indicator of the surgical extent of thyroid cancer. We evaluated the difference in tumor sizes measured by preoperative US and postoperative pathologic examination in papillary thyroid carcinoma (PTC). We reviewed the medical records of 172 consecutive patients, who underwent thyroidectomy for PTC treatment. We compared tumor size, as measured by preoperative US, with that in postoperative specimens. And we analyzed a number of factors potentially influencing the size measurement, including cancer size, calcification and coexisting thyroiditis. The mean size of the tumor measured by preoperative US was 11.4, and 10.2 mm by postoperative pathologic examination. The mean percentage difference (US-pathology/US) of tumor sizes measured by preoperative US and postoperative pathologic examination was 9.9 ± 19.3%, which was statistically significant (p 20.0 mm) and the presence of calcification or coexisting thyroiditis on the tumor size discrepancy between the two measurements was analyzed, the mean percentage differences according to tumor size (9.1 vs. 11.2% vs. 9.8%, p = 0.842), calcification (9.2 vs. 10.2%, p = 0.756) and coexisting thyroiditis (17.6 vs. 9.5%, p = 0.223) did not show statistical significance. Tumor sizes measured in postoperative pathology were ~90% of those measured by preoperative US in PTC; this was not affected by tumor size, the presence of calcification or coexisting thyroiditis. When the surgical extent of PTC treatment according to tumor size measured by US is determined, the relative difference between tumor sizes measured by preoperative US and postoperative pathologic examination should be considered.

  10. Accounting for measurement error in biomarker data and misclassification of subtypes in the analysis of tumor data.

    Science.gov (United States)

    Nevo, Daniel; Zucker, David M; Tamimi, Rulla M; Wang, Molin

    2016-12-30

    A common paradigm in dealing with heterogeneity across tumors in cancer analysis is to cluster the tumors into subtypes using marker data on the tumor, and then to analyze each of the clusters separately. A more specific target is to investigate the association between risk factors and specific subtypes and to use the results for personalized preventive treatment. This task is usually carried out in two steps-clustering and risk factor assessment. However, two sources of measurement error arise in these problems. The first is the measurement error in the biomarker values. The second is the misclassification error when assigning observations to clusters. We consider the case with a specified set of relevant markers and propose a unified single-likelihood approach for normally distributed biomarkers. As an alternative, we consider a two-step procedure with the tumor type misclassification error taken into account in the second-step risk factor analysis. We describe our method for binary data and also for survival analysis data using a modified version of the Cox model. We present asymptotic theory for the proposed estimators. Simulation results indicate that our methods significantly lower the bias with a small price being paid in terms of variance. We present an analysis of breast cancer data from the Nurses' Health Study to demonstrate the utility of our method. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. High prevalence of malnutrition among patients with solid non-hematological tumors as found by using skinfold and circumference measurements

    Directory of Open Access Journals (Sweden)

    Adriana Garófolo

    Full Text Available CONTEXT AND OBJECTIVE: Malnutrition in cancer patients has many causes. Nutritional status is usually assessed from weight/height indices. These present limitations for the nutritional assessment of cancer patients: their weights include tumor mass, and lean mass changes are not reflected in weight/height indices. The objective was to evaluate differences between two anthropometric methods and compare deficits, in non-hematological tumor patients and hematological disease patients. DESIGN AND SETTING: Cross-sectional study at Instituto de Oncologia Pediátrica, Universidade Federal de São Paulo. METHODS: Children and adolescents were evaluated between March 1998 and January 2000. Traditional anthropometric measurements were obtained in the first month of treatment (induction therapy, by weight-for-height (W/H using z-scores index for children and body mass index (BMI for adolescents. Body composition evaluations consisted of specific anthropometric measurements: triceps skinfold thickness (TSFT, mid-upper arm circumference (MUAC and arm muscle circumference (AMC. Data were analyzed to compare nutritional assessment methods for diagnosing malnutrition prevalence. The chi-squared test was used for comparative analyses between tumor patients and hematological disease patients. RESULTS: Analysis was done on 127 patients with complete data. Higher percentages of deficits were found among tumor patients, by W/H z-scores or BMI and by MUAC and AMC. Higher percentages of deficits were shown by TSFT (40.2% and MUAC (35.4% than by W/H z-scores or BMI (18.9%. CONCLUSION: Non-hematological tumor patients presented higher malnutrition prevalence than did hematological disease patients. Body composition measurements by TSFT and MUAC detected more patients with malnutrition than did W/H or BMI.

  12. Measurements of partial oxygen pressure pO2 using the OxyLite system in R3327-AT tumors under isoflurane anesthesia.

    Science.gov (United States)

    Wen, Bixiu; Urano, Muneyasu; O'Donoghue, Joseph A; Ling, C Clifton

    2006-09-01

    The presence of oxygen-deficient tumor cells is a critical issue in cancer therapy. To identify tumor hypoxia, tissue partial oxygen pressure (pO2) can be measured directly. The OxyLite system allows determination of pO2 in tumors and permits continuous measurements of pO2 at a fixed point. In this study, this system was used to continuously measure pO2 in R3327-AT tumors in animals anesthetized with isoflurane. In addition, continuous pO2 measurement was performed in the muscle in non-tumor-bearing animals. In animals breathing isoflurane balanced by air, tumor pO2 at fixed positions decreased rapidly within 1-2 min of probe positioning but remained stable thereafter. In animals breathing isoflurane balanced by pure oxygen, tumor pO2 was higher and remained high. We also measured pO2 values at multiple positions in R3327-AT tumors of various sizes, with anesthetized animals breathing either air or pure oxygen. Our data showed that the frequency of pO2 measurements below 2.5 or 5.0 mmHg was significantly higher in animals breathing air than in animals breathing pure oxygen. Measurements in different-sized tumors showed that the mean pO2 value decreased as tumor volume increased, with the largest change occurring between tumor volumes of 100 and 200 mm3. Our data demonstrate that the OxyLite system, when used with isoflurane anesthesia, is a valuable tool in the study of tumor hypoxia.

  13. Experimental study on active specific immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 4

    International Nuclear Information System (INIS)

    Imanaka, Kazufumi; Ogawa, Yasuhiro; Gose, Kyuhei; Imajo, Yoshinari; Kimura, Shuji

    1982-01-01

    We have already reported that the effectiveness of active specific immunotherapy using low-dose irradiated tumor cells and infiltrating mononuclear cells. The present study was designed to investigate the effect of non-specific immunopotentiator combined with the active specific immunotherapy. Twelve-week-aged female C3H/He mice transplanted with MM46 tumor were received local radiotherapy with the dose of 3,000 rads by high energy electron beam on the sixth day after inoculation. Active specific immunotherapy was performed on the 13th day, and daily dose of 1.0 KE of OK-432 was injected intraperitoneally from the 13th day to the 17th day. The inhibition of the tumor growth and the elongation of survival period were noted in the group which received active specific immunotherapy combined with non-specific immunopotentiator, OK-432 compared with that active specific immunotherapy alone. (author)

  14. Effects of breathing a hyperoxic hypercapnic gas mixture on blood oxygenation and vascularity of head-and-neck tumors as measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rijpkema, Mark; Kaanders, Johannes H.A.M.; Joosten, Frank; Kogel, Albert J. van der; Heerschap, Arend

    2002-01-01

    Purpose: For head-and-neck tumors, breathing a hyperoxic hypercapnic gas mixture and administration of nicotinamide has been shown to result in a significantly improved tumor response to accelerated radiotherapy (ARCON, Accelerated Radiotherapy with CarbOgen and Nicotinamide). This may be caused by improved tumor oxygenation, possibly mediated by vascular effects. In this study, both blood oxygenation and vascular effects of breathing a hyperoxic hypercapnic gas mixture (98% O 2 +2% CO 2 ) were assessed by magnetic resonance imaging (MRI) in patients with head-and-neck tumors. Methods and Materials: Tumor vascularity and oxygenation were investigated by dynamic gadolinium contrast-enhanced MRI and blood oxygen level dependent (BOLD) MRI, respectively. Eleven patients with primary head-and-neck tumors were each measured twice; with and without breathing the hyperoxic hypercapnic gas mixture. Results: BOLD MR imaging revealed a significant increase of the MRI time constant of transverse magnetization decay (T 2 *) in the tumor during hypercapnic hyperoxygenation, which correlates to a decrease of the deoxyhemoglobin concentration. No changes in overall tumor vascularity were observed, as measured by the gadolinium contrast uptake rate in the tumor. Conclusion: Breathing a hyperoxic hypercapnic gas mixture improves tumor blood oxygenation in patients with head-and-neck tumors, which may contribute to the success of the ARCON therapy

  15. The quaternary state of polymerized human hemoglobin regulates oxygenation of breast cancer solid tumors: A theoretical and experimental study

    Science.gov (United States)

    Ju, Julia A.; Baek, Jin Hyen; Yalamanoglu, Ayla; Buehler, Paul W.; Gilkes, Daniele M.; Palmer, Andre F.

    2018-01-01

    A major constraint in the treatment of cancer is inadequate oxygenation of the tumor mass, which can reduce chemotherapeutic efficacy. We hypothesize that polymerized human hemoglobin (PolyhHb) can be transfused into the systemic circulation to increase solid tumor oxygenation, and improve chemotherapeutic outcomes. By locking PolyhHb in the relaxed (R) quaternary state, oxygen (O2) offloading at low O2 tensions (20 mm Hg) is facilitated with tense (T) state PolyhHb. Therefore, R-state PolyhHb may deliver significantly more O2 to hypoxic tissues. Biophysical parameters of T and R-state PolyhHb were used to populate a modified Krogh tissue cylinder model to assess O2 transport in a tumor. In general, we found that increasing the volume of transfused PolyhHb decreased the apparent viscosity of blood in the arteriole. In addition, we found that PolyhHb transfusion decreased the wall shear stress at large arteriole diameters (>20 μm), but increased wall shear stress for small arteriole diameters (state PolyhHb may be more effective than T-state PolyhHb for O2 delivery at similar transfusion volumes. Reduction in the apparent viscosity resulting from PolyhHb transfusion may result in significant changes in flow distributions throughout the tumor microcirculatory network. The difference in wall shear stress implies that PolyhHb may have a more significant effect in capillary beds through mechano-transduction. Periodic top-load transfusions of PolyhHb into mice bearing breast tumors confirmed the oxygenation potential of both PolyhHbs via reduced hypoxic volume, vascular density, tumor growth, and increased expression of hypoxia inducible genes. Tissue section analysis demonstrated primary PolyhHb clearance occurred in the liver and spleen indicating a minimal risk for renal damage. PMID:29414985

  16. On the measurement of a weak classical force coupled to a harmonic oscillator: experimental progress

    International Nuclear Information System (INIS)

    Bocko, M.F.; Onofrio, R.

    1996-01-01

    Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them, have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. copyright 1996 The American Physical Society

  17. Calculation and experimental measurements in the Argonauta reactor subcritical and exponential facility

    International Nuclear Information System (INIS)

    Voi, Dante L.; Furieri, Rosane C.A.A.; Renke, Carlos A.C.; Bastos, Wilma S.; Ferreira, Francisco J.O.

    1997-01-01

    Initial measurements were performed on the exponential and subcritical facility installed on the internal thermal column of the Argonauta reactor at IEN-CNEN-Rio de Janeiro, Brazil. The measurements are include in the reactor physics experimental program for integral parameters determination, for both valid and confirmed theoretical models for reactor calculation. Gamma doses and neutron fluxes were measured with telescopic, proportional counters, wire and foil detectors. Experimental data were compared with results obtained by application of CITATION code. (author). 4 refs., 8 figs

  18. Experimental system to measure excitation cross-sections by electron impact. Measurements for ArI and ArII

    International Nuclear Information System (INIS)

    Blanco, F.; Sanchez, J.A.; Aguilera, J.A.; Campos, J.

    1989-01-01

    An experimental set-up to measure excitation cross-section of atomic and molecular levels by electron impact based on the optical method is reported. We also present some measurements on the excitation cross-section for ArI 5p'(1/2)0 level, and for simultaneous ionization and excitation of Ar leading to ArII levels belonging to the 3p 4 4p and 3p 4 4d configurations. (Author)

  19. Technique of measuring and evaluating the R3E dia. 112 experimental fuel element

    International Nuclear Information System (INIS)

    Stanc, S.; Badiar, S.

    1974-10-01

    The charging is considered of the R3E experimental fuel element having a diameter of 112 mm which will serve the simultaneous temperature measurement on 15 sites and neutron flux measurement on 7 sites aimed at verifying the improved R3-type fuel element with extended cladding and a new toroidal spacing. The temperature will be measured using jacket thermocouples while neutron flux will be measured by self-powered detectors. The methods are described of checking the measuring chain by determining the loop resistance of the thermocouples and SPN detectors in order to verify the correctness of the measured data. (J.B.)

  20. Effectiveness of chemotherapy in measurable granulosa cell tumors: a retrospective study and review of literature

    NARCIS (Netherlands)

    van Meurs, Hannah S.; Buist, Marrije R.; Westermann, Anneke M.; Sonke, Gabe S.; Kenter, Gemma G.; van der Velden, Jacobus

    2014-01-01

    Patients with irresectable granulosa cell tumors (GCTs) often receive chemotherapy. The effectiveness of this approach, however, is uncertain. The aim of our study was to assess the response rate to chemotherapy for residual and recurrent inoperable GCT. All consecutive chemotherapy-naive patients

  1. Sensitivity of fibroblast growth factor 23 measurements in tumor-induced osteomalacia.

    NARCIS (Netherlands)

    Imel, E.A.; Peacock, M.; Pitukcheewanont, P.; Heller, H.J.; Ward, LM; Shulman, D.; Kassem, M.; Rackoff, P.; Zimering, M.; Dalkin, A.; Drobny, E.; Colussi, G.; Shaker, J.L.; Hoogendoorn, E.H.; Hui, S.L.; Econs, M.J.

    2006-01-01

    CONTEXT: Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome of hypophosphatemia, decreased renal phosphate reabsorption, normal or low serum 1,25-dihydryxyvitamin-D concentration, myopathy, and osteomalacia. Fibroblast growth factor 23 (FGF23) is a phosphaturic protein overexpressed in

  2. Repeated tumor pO2 measurements by multi-site EPR oximetry as a prognostic marker for enhanced therapeutic efficacy of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Hou Huagang; Lariviere, Jean P.; Demidenko, Eugene; Gladstone, David; Swartz, Harold; Khan, Nadeem

    2009-01-01

    Purpose: To investigate the temporal effects of single or fractionated radiotherapy on subcutaneous RIF-1 tumor pO 2 and to determine the therapeutic outcomes when the timing of fractionations is guided by tumor pO 2 . Methods: The time-course of the tumor pO 2 changes was followed by multi-site electron paramagnetic resonance (EPR) oximetry. The tumors were treated with single 10, 20, and 10 Gy x 2 doses, and the tumor pO 2 was measured repeatedly for six consecutive days. In the 10 Gy x 2 group, the second dose of 10 Gy was delivered at a time when the tumors were either relatively oxygenated or hypoxic. The changes in tumor volumes were followed for nine days to determine the therapeutic outcomes. Results: A significant increase in tumor pO 2 was observed at 24 h post 10 Gy, while 20 Gy resulted in a significant increase in tumor pO 2 at 72-120 h post irradiation. The tumors irradiated with a second dose of 10 Gy at 24 h, when the tumors were oxygenated, had a significant increase in tumor doubling times (DTs), as compared to tumors treated at 48 h when they were hypoxic (p 2 repeatedly during fractionated schemes to optimize radiotherapeutic outcome. This technique could also be used to identify responsive and non-responsive tumors, which will facilitate the design of other therapeutic approaches for non-responsive tumors at early time points during the course of therapy.

  3. Impact of measurement uncertainty from experimental load distribution factors on bridge load rating

    Science.gov (United States)

    Gangone, Michael V.; Whelan, Matthew J.

    2018-03-01

    Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.

  4. An experimental device for measurement of gas permeation in solid matrices

    International Nuclear Information System (INIS)

    De Salve, M.; Mazzi, E.; Zucchetti, M.

    1996-01-01

    The inventory in and the permeation through fusion reactor structures of hydrogen and its isotopes play an important role in the machine operation, evolution of material properties, and safety. An experimental and research activity for the determination of permeability (and derived parameters) of gases in solid matrices is described. It uses a gas permeation method, that basically consists in the measure of the time evolution of the gas pressure in a chamber in which vacuum has been previously made (downstream volume). This chamber is separated from another one, full of the gas in exam (upstream volume), by means of a membrane of the material under study. The experimental installation is described. The first stage of the experimental activity has dealt with the set-up of the device, the volume calibration, and the definition of the parameters range for which the installation can give reliable measurements. The subsequent stage of the activity has consisted in the measurement of the permeability, and then of the diffusion coefficient, of nitrogen in some materials at room temperature. Concurrently with the experimental activity, a model has been set-up and implemented in a computer code: this code permits to evaluate the time evolution of the pressure in the downstream chamber. With this code, using the measured parameters, the time evolution of the pressure experimentally measured has been satisfactorily reproduced. (author)

  5. Experimental verification of neutron emission method for measuring of fissile material content in spent fuel

    International Nuclear Information System (INIS)

    Abou-Zaid, A.A.; Pytel, K.

    1999-01-01

    A non-destructive method of measurement of fissile nuclides content remained in spent fuel from research reactor is presented. The method, called the neutron emission one, is based on counting of fission neutrons emitted from fissile isotopes: 235 U, 239 Pu, 241 Pu. Fissions are induced mainly by neutrons supplied by the external neutron source. Another effects contribute also to the measured neutron population, e. g. source neutrons from penetrating the fuel without being captured and scattered, neutrons (α,n) reactions and from spontaneous fissions of actinides. Complexity of phenomena occurring within the measurement facility required the detailed numerical simulation and experimental studies prior design of ultimate measurement stand. In the previous paper, the results of Monte Carlo simulation on optimisation of measuring stand for neutron emission method were presented. On the basis of those results, the experimental stand for Maria reactor fuel investigation has been designed and manufactured. The present paper, being the continuation of previous one, contains the description of experimental facility and the results of measurements for the fresh fuel (without burnup) and the fuel mock-up (without fissile materials). Although some discrepancies were found between Monte Carlo and experimental results, the main conclusions concerning the optimal geometry of measuring facility have been confirmed. (author)

  6. Experimental ex-vivo validation of PMMA-based bone cements loaded with magnetic nanoparticles enabling hyperthermia of metastatic bone tumors

    Directory of Open Access Journals (Sweden)

    Mariem Harabech

    2017-05-01

    Full Text Available Percutaneous vertebroplasty comprises the injection of Polymethylmethacrylate (PMMA bone cement into vertebrae and can be used for the treatment of compression fractures of vertebrae. Metastatic bone tumors can cause such compression fractures but are not treated when injecting PMMA-based bone cement. Hyperthermia of tumors can on the other hand be attained by placing magnetic nanoparticles (MNPs in an alternating magnetic field (AMF. Loading the PMMA-based bone cement with MNPs could both serve vertebra stabilization and metastatic bone tumor hyperthermia when subjecting this PMMA-MNP to an AMF. A dedicated pancake coil is designed with a self-inductance of 10 μH in series with a capacitance of 0.1 μF that acts as resonant inductor-capacitor circuit to generate the AMF. The thermal rise is appraised in beef vertebra placed at 10 cm from the AMF generating circuit using optical temperatures sensors, i.e. in the center of the PMMA-MNP bone cement, which is located in the vicinity of metastatic bone tumors in clinical applications; and in the spine, which needs to be safeguarded to high temperature exposures. Results show a temperature rise of about 7 °C in PMMA-MNP whereas the temperature rise in the spine remains limited to 1 °C. Moreover, multicycles heating of PMMA-MNP is experimentally verified, validating the technical feasibility of having PMMA-MNP as basic component for percutaneous vertebroplasty combined with hyperthermia treatment of metastatic bone tumors.

  7. Coherent versus incoherent resonant emission: an experimental method for easy discrimination and measurement

    Science.gov (United States)

    Ceccherini, S.; Colocci, M.; Gurioli, M.; Bogani, F.

    1998-11-01

    The distinction between the coherent and the incoherent component of the radiation emitted from resonantly excited material systems is difficult experimentally, particularly when ultra-short optical pulses are used for excitation. We propose an experimental procedure allowing an easy measurement of the two components. The method is completely general and applicable to any kind of physical system; its feasibility is demonstrated on the resonant emission from excitons in a semiconductor quantum well.

  8. Light ions radiobiological effects on human tumoral cells: measurements modelling and application to hadron-therapy

    International Nuclear Information System (INIS)

    Jalade, P.

    2005-11-01

    In classical radiotherapy, the characteristics of photons interactions undergo limits for the treatment of radioresistant and not well located tumours. Pioneering treatments of patients at the Lawrence Laboratory at Berkeley has demonstrated two advantages of hadrons beams: the Relative Biologic Effect (the RBE) and the ballistic of the beams. Since 1994, the clinical centre at Chiba, has demonstrated successfully the applicability of the method. A physics group, managed by G. Kraft, at Darmstadt in Germany, has underlined the advantages of carbon beams. An European pool, called ENGIGHT (European Network for LIGHt ion Therapy) has been created in which the French ETOILE project appeared. The purpose of the thesis concerns measurements and models of 'in vitro' human cells survival. In the first part, the nowadays situation in particles interactions, tracks and cells structures and radiobiology is presented here. The second is devoted to the models based on the beam tracks and localization of the physical dose. Discussion of sensitivity to various parameters of the model has been realized with the help of numerical simulations. Finally the predictions of the improved model has been compared to experimental irradiations of human cells with argon and carbon beams of the GANIL machine. Conclusion of such study shows the performance and limits of a local model for predicting the radiobiological efficiency of light ions in hadron-therapy. (author)

  9. Comparison of lung tumor motion measured using a model-based 4DCT technique and a commercial protocol.

    Science.gov (United States)

    O'Connell, Dylan; Shaverdian, Narek; Kishan, Amar U; Thomas, David H; Dou, Tai H; Lewis, John H; Lamb, James M; Cao, Minsong; Tenn, Stephen; Percy, Lee P; Low, Daniel A

    2017-11-11

    To compare lung tumor motion measured with a model-based technique to commercial 4-dimensional computed tomography (4DCT) scans and describe a workflow for using model-based 4DCT as a clinical simulation protocol. Twenty patients were imaged using a model-based technique and commercial 4DCT. Tumor motion was measured on each commercial 4DCT dataset and was calculated on model-based datasets for 3 breathing amplitude percentile intervals: 5th to 85th, 5th to 95th, and 0th to 100th. Internal target volumes (ITVs) were defined on the 4DCT and 5th to 85th interval datasets and compared using Dice similarity. Images were evaluated for noise and rated by 2 radiation oncologists for artifacts. Mean differences in tumor motion magnitude between commercial and model-based images were 0.47 ± 3.0, 1.63 ± 3.17, and 5.16 ± 4.90 mm for the 5th to 85th, 5th to 95th, and 0th to 100th amplitude intervals, respectively. Dice coefficients between ITVs defined on commercial and 5th to 85th model-based images had a mean value of 0.77 ± 0.09. Single standard deviation image noise was 11.6 ± 9.6 HU in the liver and 6.8 ± 4.7 HU in the aorta for the model-based images compared with 57.7 ± 30 and 33.7 ± 15.4 for commercial 4DCT. Mean model error within the ITV regions was 1.71 ± 0.81 mm. Model-based images exhibited reduced presence of artifacts at the tumor compared with commercial images. Tumor motion measured with the model-based technique using the 5th to 85th percentile breathing amplitude interval corresponded more closely to commercial 4DCT than the 5th to 95th or 0th to 100th intervals, which showed greater motion on average. The model-based technique tended to display increased tumor motion when breathing amplitude intervals wider than 5th to 85th were used because of the influence of unusually deep inhalations. These results suggest that care must be taken in selecting the appropriate interval during image generation when using model-based 4DCT methods. Copyright © 2017

  10. Experimental demonstration of the finite measurement time effect on the Feynman-{alpha} technique

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E

    1998-09-01

    The reactivity of a subcritical system is determined by fitting two different theoretical models to a measured Feynman-{alpha} curve. The first model is the expression usually found in the literature, which can be shown to be the expectation value of the experimental quality if the measurement time is infinite. The second model is a new expression which is the expectation value of the experimental quantity for a finite measurement time. The reactivity inferred with the new model is seen to be independent of the length of the fitting interval, whereas the reactivity inferred with the conventional model is seen to vary. This difference demonstrates the effect of the finite measurement time. As a reference, the reactivity is also measured with the pulsed-neutron source method. It is seen to be in good agreement with the reactivity obtained with the Feynman-{alpha} technique when the new expression is applied.

  11. Development of an Experimental Measurement System for Human Error Characteristics and a Pilot Test

    International Nuclear Information System (INIS)

    Jang, Tong-Il; Lee, Hyun-Chul; Moon, Kwangsu

    2017-01-01

    Some items out of individual and team characteristics were partially selected, and a pilot test was performed to measure and evaluate them using the experimental measurement system of human error characteristics. It is one of the processes to produce input data to the Eco-DBMS. And also, through the pilot test, it was tried to take methods to measure and acquire the physiological data, and to develop data format and quantification methods for the database. In this study, a pilot test to measure the stress and the tension level, and team cognitive characteristics out of human error characteristics was performed using the human error characteristics measurement and experimental evaluation system. In an experiment measuring the stress level, physiological characteristics using EEG was measured in a simulated unexpected situation. As shown in results, although this experiment was pilot, it was validated that relevant results for evaluating human error coping effects of workers’ FFD management guidelines and unexpected situation against guidelines can be obtained. In following researches, additional experiments including other human error characteristics will be conducted. Furthermore, the human error characteristics measurement and experimental evaluation system will be utilized to validate various human error coping solutions such as human factors criteria, design, and guidelines as well as supplement the human error characteristics database.

  12. Experimental Test of Entropic Noise-Disturbance Uncertainty Relations for Spin-1/2 Measurements.

    Science.gov (United States)

    Sulyok, Georg; Sponar, Stephan; Demirel, Bülent; Buscemi, Francesco; Hall, Michael J W; Ozawa, Masanao; Hasegawa, Yuji

    2015-07-17

    Information-theoretic definitions for noise and disturbance in quantum measurements were given in [Phys. Rev. Lett. 112, 050401 (2014)] and a state-independent noise-disturbance uncertainty relation was obtained. Here, we derive a tight noise-disturbance uncertainty relation for complementary qubit observables and carry out an experimental test. Successive projective measurements on the neutron's spin-1/2 system, together with a correction procedure which reduces the disturbance, are performed. Our experimental results saturate the tight noise-disturbance uncertainty relation for qubits when an optimal correction procedure is applied.

  13. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua

    2013-01-01

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX 2 was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan–Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 ± 0.12 kg, 57.83 ± 8.68 days, (16.73 ± 5.18 %), (29.47 ± 7.18 %), and 2.03 ± 0.13 kg, 43.67 ± 5.28 days, (63.01 ± 2.01 %), (6.02 ± 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model

  14. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2013-10-15

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT

  15. Dynamic Measurement of Tumor Vascular Permeability and Perfusion using a Hybrid System for Simultaneous Magnetic Resonance and Fluorescence Imaging.

    Science.gov (United States)

    Ren, Wuwei; Elmer, Andreas; Buehlmann, David; Augath, Mark-Aurel; Vats, Divya; Ripoll, Jorge; Rudin, Markus

    2016-04-01

    Assessing tumor vascular features including permeability and perfusion is essential for diagnostic and therapeutic purposes. The aim of this study was to compare fluorescence and magnetic resonance imaging (MRI)-based vascular readouts in subcutaneously implanted tumors in mice by simultaneous dynamic measurement of tracer uptake using a hybrid fluorescence molecular tomography (FMT)/MRI system. Vascular permeability was measured using a mixture of extravascular imaging agents, GdDOTA and the dye Cy5.5, and perfusion using a mixture of intravascular agents, Endorem and a fluorescent probe (Angiosense). Dynamic fluorescence reflectance imaging (dFRI) was integrated into the hybrid system for high temporal resolution. Excellent correspondence between uptake curves of Cy5.5/GdDOTA and Endorem/Angiosense has been found with correlation coefficients R > 0.98. The two modalities revealed good agreement regarding permeability coefficients and centers-of-gravity of the imaging agent distribution. The FMT/dFRI protocol presented is able to accurately map physiological processes and poses an attractive alternative to MRI for characterizing tumor neoangiogenesis.

  16. Multi-parametric MRI of rectal cancer – Do quantitative functional MR measurements correlate with radiologic and pathologic tumor stages?

    International Nuclear Information System (INIS)

    Attenberger, U.I.; Pilz, L.R.; Morelli, J.N.; Hausmann, D.; Doyon, F.; Hofheinz, R.; Kienle, P.; Post, S.; Michaely, H.J.; Schoenberg, S.O.; Dinter, D.J.

    2014-01-01

    Purpose: The purpose of this study is two-fold. First, to evaluate, whether functional rectal MRI techniques can be analyzed in a reproducible manner by different readers and second, to assess whether different clinical and pathologic T and N stages can be differentiated by functional MRI measurements. Materials and methods: 54 patients (38 men, 16 female; mean age 63.2 ± 12.2 years) with pathologically proven rectal cancer were included in this retrospective IRB-approved study. All patients were referred for a multi-parametric MRI protocol on a 3 Tesla MR-system, consisting of a high-resolution, axial T2 TSE sequence, DWI and perfusion imaging (plasma flow –s PF Tumor ) prior to any treatment. Two experienced radiologists evaluated the MRI measurements, blinded to clinical data and outcome. Inter-reader correlation and the association of functional MRI parameters with c- and p-staging were analyzed. Results: The inter-reader correlation for lymph node (ρ 0.76–0.94; p < 0.0002) and primary tumor (ρ 0.78–0.92; p < 0.0001) apparent diffusion coefficient and plasma flow (PF) values was good to very good. PF Tumor values decreased with cT stage with significant differences identified between cT2 and cT3 tumors (229 versus 107.6 ml/100 ml/min; p = 0.05). ADC Tumor values did not differ significantly. No substantial discrepancies in lymph node ADC Ln values or short axis diameter were found among cN1-3 stages, whereas PF Ln values were distinct between cN1 versus cN2 stages (p = 0.03). In the patients without neoadjuvant RCT no statistically significant differences in the assessed functional parameters on the basis of pathologic stage were found. Conclusion: This study illustrates that ADC as well as MR perfusion values can be analyzed with good interobserver agreement in patients with rectal cancer. Moreover, MR perfusion parameters may allow accurate differentiation of tumor stages. Both findings suggest that functional MRI parameters may help to discriminate

  17. Measurements of experimental precision for trials with cowpea (Vigna unguiculata L. Walp.) genotypes.

    Science.gov (United States)

    Teodoro, P E; Torres, F E; Santos, A D; Corrêa, A M; Nascimento, M; Barroso, L M A; Ceccon, G

    2016-05-09

    The aim of this study was to evaluate the suitability of statistics as experimental precision degree measures for trials with cowpea (Vigna unguiculata L. Walp.) genotypes. Cowpea genotype yields were evaluated in 29 trials conducted in Brazil between 2005 and 2012. The genotypes were evaluated with a randomized block design with four replications. Ten statistics that were estimated for each trial were compared using descriptive statistics, Pearson correlations, and path analysis. According to the class limits established, selective accuracy and F-test values for genotype, heritability, and the coefficient of determination adequately estimated the degree of experimental precision. Using these statistics, 86.21% of the trials had adequate experimental precision. Selective accuracy and the F-test values for genotype, heritability, and the coefficient of determination were directly related to each other, and were more suitable than the coefficient of variation and the least significant difference (by the Tukey test) to evaluate experimental precision in trials with cowpea genotypes.

  18. Experimental measurements and prediction of liquid densities for n-alkane mixtures

    International Nuclear Information System (INIS)

    Ramos-Estrada, Mariana; Iglesias-Silva, Gustavo A.; Hall, Kenneth R.

    2006-01-01

    We present experimental liquid densities for n-pentane, n-hexane and n-heptane and their binary mixtures from (273.15 to 363.15) K over the entire composition range (for the mixtures) at atmospheric pressure. A vibrating tube densimeter produces the experimental densities. Also, we present a generalized correlation to predict the liquid densities of n-alkanes and their mixtures. We have combined the principle of congruence with the Tait equation to obtain an equation that uses as variables: temperature, pressure and the equivalent carbon number of the mixture. Also, we present a generalized correlation for the atmospheric liquid densities of n-alkanes. The average absolute percentage deviation of this equation from the literature experimental density values is 0.26%. The Tait equation has an average percentage deviation of 0.15% from experimental density measurements

  19. Further optimization studies of experimental dynamic responses measured on the HTGC Dragon reactor

    International Nuclear Information System (INIS)

    Cummins, J.D.

    1968-04-01

    This report considers some measurements made of the dynamics of the HTGC Dragon reactor and the optimization of a mathematical model which represents the reactor, by altering the parameters until a least squares fit between the experimental responses and the mathematical model is obtained. The experimental information was processed in various ways. The experimental response to an impulse, step or periodic sine wave change in reactivity was processed as an impulse, step or periodic sine wave response respectively and compared with a similar response from the model. In other studies the result of a binary cross correlation experiment (effectively an impulse response input) was processed as a frequency response and this experimental frequency response was compared with the frequency response from the mathematical model. It was possible therefore to compare the optimum values of parameters, obtained for different forms of perturbing signal and for different methods of processing and to relate the optima obtained to the problem of parameter estimation. (author)

  20. Influence of rotational setup error on tumor shift in bony anatomy matching measured with pulmonary point registration in stereotactic body radiotherapy for early lung cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2012-01-01

    The objective of this study was to examine the correlation between the patient rotational error measured with pulmonary point registration and tumor shift after bony anatomy matching in stereotactic body radiotherapy for lung cancer. Twenty-six patients with lung cancer who underwent stereotactic body radiotherapy were the subjects. On 104 cone-beam computed tomography measurements performed prior to radiation delivery, rotational setup errors were measured with point registration using pulmonary structures. Translational registration using bony anatomy matching was done and the three-dimensional vector of tumor displacement was measured retrospectively. Correlation among the three-dimensional vector and rotational error and vertebra-tumor distance was investigated quantitatively. The median and maximum rotational errors of the roll, pitch and yaw were 0.8, 0.9 and 0.5, and 6.0, 4.5 and 2.5, respectively. Bony anatomy matching resulted in a 0.2-1.6 cm three-dimensional vector of tumor shift. The shift became larger as the vertebra-tumor distance increased. Multiple regression analysis for the three-dimensional vector indicated that in the case of bony anatomy matching, tumor shifts of 5 and 10 mm were expected for vertebra-tumor distances of 4.46 and 14.1 cm, respectively. Using pulmonary point registration, it was found that the rotational setup error influences the tumor shift. Bony anatomy matching is not appropriate for hypofractionated stereotactic body radiotherapy with a tight margin. (author)

  1. Improved Debulking of Peritoneal Tumor Implants by Near-Infrared Fluorescent Nanobody Image Guidance in an Experimental Mouse Model.

    Science.gov (United States)

    Debie, Pieterjan; Vanhoeij, Marian; Poortmans, Natalie; Puttemans, Janik; Gillis, Kris; Devoogdt, Nick; Lahoutte, Tony; Hernot, Sophie

    2017-10-31

    Debulking followed by combination chemotherapy is currently regarded as the most effective treatment for advanced ovarian cancer. Prognosis depends drastically on the degree of debulking. Accordingly, near-infrared (NIR) fluorescence imaging has been proposed to revolutionize cancer surgery by acting as a sensitive, specific, and real-time tool enabling visualization of cancer lesions. We have previously developed a NIR-labeled nanobody that allows fast, specific, and high-contrast imaging of HER2-positive tumors. In this study, we applied this tracer during fluorescence-guided surgery in a mouse model and investigated the effect on surgical efficiency. 0.5 × 10 6 SKOV3.IP1-Luc+ cells were inoculated intraperitoneally in athymic mice and were allowed to grow for 30 days. Two nanomoles of IRDye800CW-anti-HER2 nanobody was injected intravenously. After 1h30, mice were killed, randomized in two groups, and subjected to surgery. In the first animal group (n = 7), lesions were removed by a conventional surgical protocol, followed by excision of remaining fluorescent tissue using a NIR camera. The second group of mice (n = 6) underwent directly fluorescence-guided surgery. Bioluminescence imaging was performed before and after surgery. Resected tissue was categorized as visualized during conventional surgery or not, fluorescent or not, and bioluminescent positive or negative. Fluorescence imaging allowed clear visualization of tumor nodules within the abdomen, up to submillimeter-sized lesions. Fluorescence guidance resulted in significantly reduced residual tumor as compared to conventional surgery. Moreover, sensitivity increased from 59.3 to 99.0 %, and the percentage of false positive lesions detected decreased from 19.6 to 7.1 %. This study demonstrates the advantage of intraoperative fluorescence imaging using nanobody-based tracers on the efficiency of debulking surgery.

  2. Ceacam1 separates graft-versus-host-disease from graft-versus-tumor activity after experimental allogeneic bone marrow transplantation.

    Directory of Open Access Journals (Sweden)

    Sydney X Lu

    Full Text Available Allogeneic bone marrow transplantation (allo-BMT is a potentially curative therapy for a variety of hematologic diseases, but benefits, including graft-versus-tumor (GVT activity are limited by graft-versus-host-disease (GVHD. Carcinoembryonic antigen related cell adhesion molecule 1 (Ceacam1 is a transmembrane glycoprotein found on epithelium, T cells, and many tumors. It regulates a variety of physiologic and pathological processes such as tumor biology, leukocyte activation, and energy homeostasis. Previous studies suggest that Ceacam1 negatively regulates inflammation in inflammatory bowel disease models.We studied Ceacam1 as a regulator of GVHD and GVT after allogeneic bone marrow transplantation (allo-BMT in mouse models. In vivo, Ceacam1(-/- T cells caused increased GVHD mortality and GVHD of the colon, and greater numbers of donor T cells were positive for activation markers (CD25(hi, CD62L(lo. Additionally, Ceacam1(-/- CD8 T cells had greater expression of the gut-trafficking integrin α(4β(7, though both CD4 and CD8 T cells were found increased numbers in the gut post-transplant. Ceacam1(-/- recipients also experienced increased GVHD mortality and GVHD of the colon, and alloreactive T cells displayed increased activation. Additionally, Ceacam1(-/- mice had increased mortality and decreased numbers of regenerating small intestinal crypts upon radiation exposure. Conversely, Ceacam1-overexpressing T cells caused attenuated target-organ and systemic GVHD, which correlated with decreased donor T cell numbers in target tissues, and mortality. Finally, graft-versus-tumor survival in a Ceacam1(+ lymphoma model was improved in animals receiving Ceacam1(-/- vs. control T cells.We conclude that Ceacam1 regulates T cell activation, GVHD target organ damage, and numbers of donor T cells in lymphoid organs and GVHD target tissues. In recipients of allo-BMT, Ceacam1 may also regulate tissue radiosensitivity. Because of its expression on both the

  3. Progress in nuclear measuring and experimental techniques by application of microelectronics. 1

    International Nuclear Information System (INIS)

    Meiling, W.

    1984-01-01

    In the past decade considerable progress has been made in nuclear measuring and experimental techniques by developing position-sensitive detector systems and widely using integrated circuits and microcomputers for data acquisition and processing as well as for automation of measuring processes. In this report which will be published in three parts those developments are reviewed and demonstrated on selected examples. After briefly characterizing microelectronics, the use of microelectronic elements for radiation detectors is reviewed. (author)

  4. Experimental test of far-infrared polarimetry for Faraday rotation measurements on the TFR 600 Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Soltwisch, H [Kernforschungsanlage Juelich G.m.b.H. (Germany, F.R.). Inst. fuer Plasmaphysik; Association Euratom-Kernforschungsanlage Juelich G.m.b.H. (Germany, F.R.)); Equipe, T F.R. [Association Euratom-CEA sur la Fusion, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Recherches sur la Fusion Controlee

    1981-09-01

    The results are reported on the feasibility of using far-infrared polarimetry for Faraday rotation diagnostic measurements on the TRF Tokamak. Precise quantitative results were not obtained but a satisfactory agreement with a simple theoretical model leads to a good understanding of the experimental limitations of the method.

  5. Experimental evaluation of permanent magnet probe flowmeter measuring high temperature liquid sodium flow in the ITSL

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Uiju; Kim, Yun Ho [Nuclear engineering Department, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Kim, Jong-Man; Kim, Tae-Joon [Korea Atomic Energy Research Institute, 1045 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Sung Joong, E-mail: sungjkim@mit.edu [Nuclear engineering Department, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

    2013-12-15

    Highlights: • An Instrument Test Sodium Loop (ITSL) has been built and tested in various conditions at KAERI. • Free fall of liquid sodium was conducted experimentally and numerically. • A Permanent Magnet Probe Flowmeter (PMPF) was experimented in the ITSL. • Excellent linearity of the PMPF was achieved under high temperature condition. - Abstract: The Instrument Test Sodium Loop (ITSL) installed at Korea Atomic Energy Research Institute (KAERI) is a medium-size experimental facility dedicated to obtaining relevant experimental data of liquid sodium flow characteristics under various thermal hydraulic conditions and sodium purification. The ITSL has been utilized to perform thermal flow measurement of the liquid sodium and to calibrate a Permanent Magnet Probe Flowmeter (PMPF). The primary objective of this study is to obtain liquid sodium flow rate given a wide temperature range using the PMPF. Non-stationary method was adopted for the calibration of the probe given the liquid sodium temperature range of 150–415 °C. A relationship between the measured voltage signal and flow rate was obtained successfully. It is observed that the calibration experiments result in excellent linear relationships between measured voltage and volumetric flow rate at various temperature conditions. Also a computational analysis using FlowMaster, is employed to facilitate the calibration process by predicting the liquid sodium flow rate. Finally the effect of the fluid temperature on thermal flow measurements is discussed in light of the obtained experimental data.

  6. Development of the Neuron Assessment for Measuring Biology Students' Use of Experimental Design Concepts and Representations

    Science.gov (United States)

    Dasgupta, Annwesa P.; Anderson, Trevor R.; Pelaez, Nancy J.

    2016-01-01

    Researchers, instructors, and funding bodies in biology education are unanimous about the importance of developing students' competence in experimental design. Despite this, only limited measures are available for assessing such competence development, especially in the areas of molecular and cellular biology. Also, existing assessments do not…

  7. Experimentally Measured Susceptibility to Peer Influence and Adolescent Sexual Behavior Trajectories: A Preliminary Study

    Science.gov (United States)

    Choukas-Bradley, Sophia; Giletta, Matteo; Widman, Laura; Cohen, Geoffrey L.; Prinstein, Mitchell J.

    2014-01-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat room" paradigm involving…

  8. Experimentally measured susceptibility to peer influence and adolescent sexual behavior trajectories : A preliminary study

    NARCIS (Netherlands)

    Choukas-Bradley, S.; Giletta, M.; Widman, L.; Cohen, G.L.; Prinstein, M.J.

    2014-01-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat

  9. An experimental model for measuring gastrointestinal bleeding rate using Tc-99m DTPA in rabbits

    International Nuclear Information System (INIS)

    Owunwanne, A.; Abdel-Dayem, H.M.; Sadek, S.; Yakoub, T.; Mahajan, K.K.; Ericsson, S.B.

    1987-01-01

    An animal experimental model to measure the rate of gastrointestinal bleeding rate in a rabbit using Tc-99m DTPA is described. It was possible to detect a bleeding rate of 0.1 ml/min. However, the model could not be used to calculate the minimum amount of radioactivity needed to detect the bleeding site. (orig.) [de

  10. On the Dielectric Constant for Acetanilide: Experimental Measurements and Effect on Energy Transport

    Science.gov (United States)

    Careri, G.; Compatangelo, E.; Christiansen, P. L.; Halding, J.; Skovgaard, O.

    1987-01-01

    Experimental measurements of the dielectric constant for crystalline acetanilide powder for temperatures ranging from - 140°C to 20°C and for different hydration levels are presented. A Davydov-soliton computer model predicts dramatic changes in the energy transport and storage for typically increased values of the dielectric constant.

  11. Experimental measurements of the solubility of technetium under near-field conditions

    International Nuclear Information System (INIS)

    Pilkington, N.J.; Wilkins, J.D.

    1988-05-01

    The solubility of technetium in contact with hydrated technetium dioxide under near-field conditions has been measured experimentally. The values obtained were changed little by a change in pH or in the filtration method used. The presence of organic degradation products increased slightly the solution concentration of technetium. (author)

  12. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, C. A. A.; Smilde, A. K.; Doornbos, D. A.

    1993-01-01

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  13. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, CAA; SMILDE, AK; DOORNBOS, DA

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  14. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  15. CT volumetric measurement of colorectal cancer helps predict tumor staging and prognosis.

    Directory of Open Access Journals (Sweden)

    Jin Young Park

    Full Text Available To evaluate feasibility of CT colonography (CTC volumetry of colorectal cancer (CRC and its correlation with disease stage and patients' survival.CTC volumetry was performed for 126 patients who underwent preoperative CTC. Reproducibility of tumor volume (Tvol between two readers was assessed. One-way ANOVA and ROC analysis evaluated correlation between Tvol and pTNM staging. ROC analysis compared diagnostic performance to predict pTNM staging between Tvol and radiologist. Kaplan-Meier test compared overall survival.Reproducibility among readers was excellent (interclass correlation = 0.9829. Mean Tvol showed an incremental trend with T stage and Tvol of pT4b stage was significantly larger than other stages (P0.05. Smaller tumor burden (≤12.85cm3, ≤T3, N0, M0 stages, and curative surgery were significantly associated with patients' longer survival (P<0.05.CT volumetry has a limited value to predict N stage; however, it may outperform the radiologist's performance when predicting pT4b and M1b stage and can be a useful prognostic marker.

  16. Calibration of uncertain inputs to computer models using experimentally measured quantities and the BMARS emulator

    International Nuclear Information System (INIS)

    Stripling, H.F.; McClarren, R.G.; Kuranz, C.C.; Grosskopf, M.J.; Rutter, E.; Torralva, B.R.

    2011-01-01

    We present a method for calibrating the uncertain inputs to a computer model using available experimental data. The goal of the procedure is to produce posterior distributions of the uncertain inputs such that when samples from the posteriors are used as inputs to future model runs, the model is more likely to replicate (or predict) the experimental response. The calibration is performed by sampling the space of the uncertain inputs, using the computer model (or, more likely, an emulator for the computer model) to assign weights to the samples, and applying the weights to produce the posterior distributions and generate predictions of new experiments within confidence bounds. The method is similar to the Markov chain Monte Carlo (MCMC) calibration methods with independent sampling with the exception that we generate samples beforehand and replace the candidate acceptance routine with a weighting scheme. We apply our method to the calibration of a Hyades 2D model of laser energy deposition in beryllium. We employ a Bayesian Multivariate Adaptive Regression Splines (BMARS) emulator as a surrogate for Hyades 2D. We treat a range of uncertainties in our system, including uncertainties in the experimental inputs, experimental measurement error, and systematic experimental timing errors. The results of the calibration are posterior distributions that both agree with intuition and improve the accuracy and decrease the uncertainty in experimental predictions. (author)

  17. Measuring and Advancing Experimental Design Ability in an Introductory Course without Altering Existing Lab Curriculum

    Directory of Open Access Journals (Sweden)

    Ryan A. Shanks

    2017-05-01

    Full Text Available Introductory biology courses provide an important opportunity to prepare students for future courses, yet existing cookbook labs, although important in their own way, fail to provide many of the advantages of semester-long research experiences. Engaging, authentic research experiences aid biology students in meeting many learning goals. Therefore, overlaying a research experience onto the existing lab structure allows faculty to overcome barriers involving curricular change. Here we propose a working model for this overlay design in an introductory biology course and detail a means to conduct this lab with minimal increases in student and faculty workloads. Furthermore, we conducted exploratory factor analysis of the Experimental Design Ability Test (EDAT and uncovered two latent factors which provide valid means to assess this overlay model’s ability to increase advanced experimental design abilities. In a pre-test/post-test design, we demonstrate significant increases in both basic and advanced experimental design abilities in an experimental and comparison group. We measured significantly higher gains in advanced experimental design understanding in students in the experimental group. We believe this overlay model and EDAT factor analysis contribute a novel means to conduct and assess the effectiveness of authentic research experiences in an introductory course without major changes to the course curriculum and with minimal increases in faculty and student workloads.

  18. Experimental sources of variation in avian energetics: estimated basal metabolic rate decreases with successive measurements.

    Science.gov (United States)

    Jacobs, Paul J; McKechnie, Andrew E

    2014-01-01

    Basal metabolic rate (BMR) is one of the most widely used metabolic variables in endotherm ecological and evolutionary physiology. Surprisingly few studies have investigated how BMR is influenced by experimental and analytical variables over and above the standardized conditions required for minimum normothermic resting metabolism. We tested whether avian BMR is affected by habituation to the conditions experienced during laboratory gas exchange measurements by measuring BMR five times in succession in budgerigars (Melopsittacus undulatus) housed under constant temperature and photoperiod. Both the magnitude and the variability of BMR decreased significantly with repeated measurements, from 0.410 ± 0.092 W (n = 9) during the first measurement to 0.285 ± 0.042 W (n = 9) during the fifth measurement. Thus, estimated BMR decreased by ∼30% within individuals solely on account of the number of times they had previously experienced the experimental conditions. The most likely explanation for these results is an attenuation with repeated exposure of the acute stress response induced by birds being handled and placed in respirometry chambers. Our data suggest that habituation to experimental conditions is potentially an important determinant of observed BMR, and this source of variation needs to be taken into account in future studies of metabolic variation among individuals, populations, and species.

  19. Role of experimental resolution in measurements of critical layer thickness for strained-layer epitaxy

    International Nuclear Information System (INIS)

    Fritz, I.J.

    1987-01-01

    Experimental measurements of critical layer thicknesses (CLT's) in strained-layer epitaxy are considered. Finite experimental resolution can have a major effect on measured CLT's and can easily lead to spurious results. The theoretical approach to critical layer thicknesses of J. W. Matthews [J. Vac. Sci. Technol. 12, 126 (1975)] has been modified in a straightforward way to predict the apparent critical thickness for an experiment with finite resolution in lattice parameter. The theory has also been modified to account for the general empirical result that fewer misfit dislocations are generated than predicted by equilibrium calculation. The resulting expression is fit to recent x-ray diffraction data on InGaAs/GaAs and SiGe/Si. The results suggest that CLT's in these systems may not be significantly larger than predicted by equilibrium theory, in agreement with high-resolution measurements

  20. Preparation of a folate-mediated tumor targeting ultraparamagnetic polymeric micelles and its in vitro experimental study

    International Nuclear Information System (INIS)

    Hong Guobin; Zhou Jingxing; Shen Jun; Liang Biling; Yuan Renxu; Shuai Xintao

    2008-01-01

    Objective: To evaluate the tumor targeting characteristic of the Folate-SPIO-DOX- Micelles by in vitro studies, and to test the feasibility of monitor tumor targeting using it and clinical MRI. Methods: The polymeric micelles, Folate-SPIO-DOXO-Micelles were prepared. The in vitro tumor cell targeting efficacy of these folate modified and DOX or SPIO-loaded micelles (Folate-SPIO-DOX- MiceUes) was evaluated by observing the cellular uptake of micelles by human hepatic carcinoma cells (Bel 7402 cells) which overexpressed folate surface receptors. Cell suspensions were incubated with Folate-SPIO- DOXO-Micelles for 1 h. Prussian blue staining was performed to show intracellular irons. Flow cytometry was used to further quantify the cellular uptake of the nanoparticles into Bel 7402 cells. MRI was performed to show the signal intensity changes by using T 2 WI sequences at a clinical 1.5 T MR system. Results Prussian blue staining showed much more intracellular iron in cells incubated with Folate-SPIO-DOX- Micelles than the cells incubated with the non-targeting SPIO-DOX-Micelles. As revealed by flow cytometry, the mean fluorescence intensity of cells in the folate group and the non-folate group were 117.88 and 46. 33, respectively. The T 2 signal intensity in MRI of cells treated with the folate targeting micelles decreased significantly(when the concentration of SPIO in cell culture medium was 5, 10, 20, 40, and 80 μg/ml, respectively, T 2 signal intensity decreased by -5.02%, -23.58%, -45.89%, -70.34%, and -92.41%, respectively). In contrast, T 2 signal intensity did not show obvious decrease for cells treated with the folate-free micelles (when the concentration of SPIO in cell culture medium was at 5, 10, 20, 40, and 80 μg/ml, respectively, T 2 signal intensity decreased by -3.77%, -2.16%, -2.18%, -2.74% and -19.77%, respectively). Conclusion: The polymeric micelles, Folate-SPIO-DOX-Micelles has good targeting ability to the hepatic carcinoma cells in vitro, and

  1. Flow-based vulnerability measures for network component importance: Experimentation with preparedness planning

    International Nuclear Information System (INIS)

    Nicholson, Charles D.; Barker, Kash; Ramirez-Marquez, Jose E.

    2016-01-01

    This work develops and compares several flow-based vulnerability measures to prioritize important network edges for the implementation of preparedness options. These network vulnerability measures quantify different characteristics and perspectives on enabling maximum flow, creating bottlenecks, and partitioning into cutsets, among others. The efficacy of these vulnerability measures to motivate preparedness options against experimental geographically located disruption simulations is measured. Results suggest that a weighted flow capacity rate, which accounts for both (i) the contribution of an edge to maximum network flow and (ii) the extent to which the edge is a bottleneck in the network, shows most promise across four instances of varying network sizes and densities. - Highlights: • We develop new flow-based measures of network vulnerability. • We apply these measures to determine the importance of edges after disruptions. • Networks of varying size and density are explored.

  2. 1988 Progress report of the EDF department for the analysis of experimental data and measurements

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The 1988 activity report of the department for the analysis of experimental data and measurements (Department of Retour d'Experience Mesures-Essais, of EDF, France), is presented. The mission of the department is to collect and investigate data from the nuclear power plant operations. The investigations started before 1988, were carried on in 1988. The department main activities are: technology and information transfer from experimental activities, the construction of a standard data acquisition and processing system, the actions involving the N4 turbine, and the modelling and construction of new non-destructive methods of control. The most important facts and activities carried out in 1988 are presented [fr

  3. Inverse kinetics technique for reactor shutdown measurement: an experimental assessment. [AGR

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T. A.; McDonald, D.

    1975-09-15

    It is proposed to use the Inverse Kinetics Technique to measure the subcritical reactivity as a function of time during the testing of the nitrogen injection systems on AGRs. A description is given of an experimental assessment of the technique by investigating known transients created by control rod movements on a small experimental reactor, (2m high, 1m radius). Spatial effects were observed close to the moving rods but otherwise derived reactivities were independent of detector position and agreed well with the existing calibrations. This prompted the suggestion that data from installed reactor instrumentation could be used to calibrate CAGR control rods.

  4. Experimental measurements of competition between fundamental and second harmonic emission in a quasi-optical gyrotron

    International Nuclear Information System (INIS)

    Alberti, S.; Pedrozzi, M.; Tran, M.Q.; Hogge, J.P.; Tran, T.M.; Muggli, P.; Joedicke, B.; Mathews, H.G.

    1990-04-01

    A quasi-optical gyrotron (QOG) designed for operation at the fundamental (Ω ce ≅100 GHz) exhibits simultaneous emission at Ω ce and 2Ω ce (second harmonic). For a beam current of 4 A, 20% of the total RF power is emitted at the second harmonic. The experimental measurements show that the excitation of the second harmonic is only possible when the fundamental is present. The frequency of the second harmonic is locked by the frequency of the fundamental. Experimental evidence shows that when the second harmonic is not excited, total efficiency is enhanced. (author) 6 refs., 5 figs., 1 tab

  5. Improvements in the measurement system of a biological Magnetic Induction Tomographical experimental setup

    International Nuclear Information System (INIS)

    Bras, N. B.; Martins, R. C.; Serra, A. C.

    2010-01-01

    Magnetic Induction Tomography (MIT) is an imaging technique that allows mapping the internal structure complex conductivity of a body. In this paper a feasibility study to implement a higher resolution MIT system for biological tissues is carried out. Recent improvements in measured signal stability and accuracy as well as a much improved angular resolution measurement of the multi-coil setup are presented which, together with a new mechanical design allows obtaining longer stable and more accurate acquisitions. This allows improving the number of measurements without trends or external perturbations, leading to a better conductivity resolution and to an enhanced image reconstruction. Throughout the paper experimental data is used to consolidate results.

  6. Measurements of gamma-ray energy deposition in a heterogeneous reactor experimental configuration and their analysis

    International Nuclear Information System (INIS)

    Calamand, D.; Wouters, R. de; Knipe, A.D.; Menil, R.

    1984-10-01

    An important contribution to the power output of a fast reactor is provided by the energy deposition from gamma-rays, and is particularly significant in the inner fertile zones of heterogeneous breeder reactor designs. To establish the validity of calculational methods and data for such systems an extensive series of measurements was performed in the zero power reactor Masurca, as part of the RACINE programme. The experimental study involved four European laboratories and the measurement techniques covered a range of thermoluminescent dosemeters and an ionization chamber. The present paper describes and compares the gamma-ray energy deposition measurements and analysis

  7. Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Jørgensen, Jesper Tranekjaer; Binderup, Tina

    2008-01-01

    BACKGROUND: In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate...... (n = 20) was determined in vivo by external caliper, microCT and 18F-FDG-PET and subsequently reference volume was determined ex vivo. Intra-observer reproducibility of the microCT and caliper methods were determined by acquiring 10 repeated volume measurements. Volumes of a group of tumors (n = 10......) were determined independently by two observers to assess inter-observer variation. RESULTS: Tumor volume measured by microCT, PET and caliper all correlated with reference volume. No significant bias of microCT measurements compared with the reference was found, whereas both PET and caliper had...

  8. The effect of clomethiazole on plasma concentrations of interleukin-6, -8, -1beta, tumor necrosis factor-alpha, and neutrophil adhesion molecule expression during experimental extracorporeal circulation.

    LENUS (Irish Health Repository)

    Harmon, D

    2012-02-03

    Clomethiazole (CMZ), a neuroprotective drug, has antiinflammatory actions. We investigated the effects of CMZ administration on plasma concentrations of interleukin (IL)-6, IL-8, IL-1beta, tumor necrosis factor-alpha, and neutrophil adhesion molecule expression during experimental extracorporeal circulation. Five healthy volunteers each donated 500 mL of blood, which was subsequently divided into equal portions. Identical extracorporeal circuits were simultaneously primed with donated blood (250 mL) and circulated for 2 h at 37 degrees C. CMZ was added to 1 of the circuits of each pair to achieve a total plasma concentration of 40 micro mol\\/L. Blood samples were withdrawn at (i) donation, (ii) immediately after addition of CMZ, and at (iii) 30, 60, 90, and 120 min after commencing circulation. Plasma concentrations of IL-6, IL-8, and tumor necrosis factor-alpha were less in the CMZ group compared with control after 60 min of circulation (2.2 [0.3] versus 3.2 [0.4], 14.9 [4.8] versus 21.9 [18.4], 63.3 [43.5] versus 132.2 [118.9] pg\\/mL, respectively, P < 0.05). After 120 min of circulation, neutrophils from CMZ-treated circuits showed significantly less CD18 expression compared with control (237.5 [97.4] versus 280.5 [111.5], P = 0.03). The addition of CMZ to experimental extracorporeal circuits decreases the inflammatory response. This effect may be of clinical benefit by decreasing inflammatory-mediated neurological injury during cardiopulmonary bypass. IMPLICATIONS: Enhancement of gamma-aminobutyric acid(A)-mediated effects by clomethiazole (CMZ) and associated neuroprotection has been established in animal models of cerebral ischemia. In an ex vivo study, we demonstrated antiinflammatory activity of CMZ in experimental extracorporeal circulation. This represents a potential neuroprotective mechanism of CMZ in patients undergoing coronary artery bypass surgery.

  9. Experimental Measurements of Temporal Dispersion for Underwater Laser Communications and Imaging

    Science.gov (United States)

    Cochenour, Brandon Michael

    The challenge in implementing optical sensors underwater lies in the high variability of the ocean environment where propagation of light in the ocean is complicated by absorption and scattering. Most underwater optical sensors operate in the blue/green portion of the electromagnetic spectrum where seawater exhibits an absorption minimum. Mitigating scattering however is a greater challenge. In particular, scattering causes both spatial distortion (beam spreading) and temporal dispersion (pulse spreading or distortion). Each of type of dispersion decreases sensor performance (operating range, image resolution, data bandwidth, etc.). While spatial dispersion has received a great deal of attention in previous decades, technological limitations of sensor hardware have made experimental measurements of temporal dispersion underwater difficult until now. The main contribution of this thesis are experimental measurements of temporal dispersion of optical beams in turbid water, made with a high sensitivity/high dynamic range experimental technique. Measurements are performed as a function of water clarity (0-20 attenuation lengths), transmitter/receiver alignment (0-30 degrees, half angle), receiver field of view (1-7 degrees, full angle), and transmitter beam divergence (collimated and diffuse). Special attention is paid to the interdependency between spatial and temporal dispersion. This work provides severable notable contributions: 1. While experimental characterization of spatial dispersion has received significant attention underwater, there has been a lack of measurements characterizing temporal dispersion underwater. This work provides the most comprehensive set of experimental measurements to date regarding the temporal dispersion of optical beams underwater. 2. An experimental analysis of the influence of scattering phase function on temporal dispersion. Coarse estimates of the scattering phase function are used to determine the ranges (or attenuation lengths

  10. An experimental method for making spectral emittance and surface temperature measurements of opaque surfaces

    International Nuclear Information System (INIS)

    Moore, Travis J.; Jones, Matthew R.; Tree, Dale R.; Daniel Maynes, R.; Baxter, Larry L.

    2011-01-01

    An experimental procedure has been developed to make spectral emittance and temperature measurements. The spectral emittance of an object is calculated using measurements of the spectral emissive power and of the surface temperature of the object obtained using a Fourier transform infrared (FTIR) spectrometer. A calibration procedure is described in detail which accounts for the temperature dependence of the detector. The methods used to extract the spectral emissive power and surface temperature from measured infrared spectra were validated using a blackbody radiator at known temperatures. The average error in the measured spectral emittance was 2.1% and the average difference between the temperature inferred from the recorded spectra and the temperature indicated on the blackbody radiator was 1.2%. The method was used to measure the spectral emittance of oxidized copper at various temperatures.

  11. Experimental study on performance verification tests for coordinate measuring systems with optical distance sensors

    Science.gov (United States)

    Carmignato, Simone

    2009-01-01

    Optical sensors are increasingly used for dimensional and geometrical metrology. However, the lack of international standards for testing optical coordinate measuring systems is currently limiting the traceability of measurements and the easy comparison of different optical systems. This paper presents an experimental investigation on artefacts and procedures for testing coordinate measuring systems equipped with optical distance sensors. The work is aimed at contributing to the standardization of testing methods. The VDI/VDE 2617-6.2:2005 guideline, which is probably the most complete document available at the state of the art for testing systems with optical distance sensors, is examined with specific experiments. Results from the experiments are discussed, with particular reference to the tests used for determining the following characteristics: error of indication for size measurement, probing error and structural resolution. Particular attention is given to the use of artefacts alternative to gauge blocks for determining the error of indication for size measurement.

  12. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-09-15

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society.

  13. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    International Nuclear Information System (INIS)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H.

    2008-09-01

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society

  14. Experimental Influences in the Accurate Measurement of Cartilage Thickness in MRI.

    Science.gov (United States)

    Wang, Nian; Badar, Farid; Xia, Yang

    2018-01-01

    Objective To study the experimental influences to the measurement of cartilage thickness by magnetic resonance imaging (MRI). Design The complete thicknesses of healthy and trypsin-degraded cartilage were measured at high-resolution MRI under different conditions, using two intensity-based imaging sequences (ultra-short echo [UTE] and multislice-multiecho [MSME]) and 3 quantitative relaxation imaging sequences (T 1 , T 2 , and T 1 ρ). Other variables included different orientations in the magnet, 2 soaking solutions (saline and phosphate buffered saline [PBS]), and external loading. Results With cartilage soaked in saline, UTE and T 1 methods yielded complete and consistent measurement of cartilage thickness, while the thickness measurement by T 2 , T 1 ρ, and MSME methods were orientation dependent. The effect of external loading on cartilage thickness is also sequence and orientation dependent. All variations in cartilage thickness in MRI could be eliminated with the use of a 100 mM PBS or imaged by UTE sequence. Conclusions The appearance of articular cartilage and the measurement accuracy of cartilage thickness in MRI can be influenced by a number of experimental factors in ex vivo MRI, from the use of various pulse sequences and soaking solutions to the health of the tissue. T 2 -based imaging sequence, both proton-intensity sequence and quantitative relaxation sequence, similarly produced the largest variations. With adequate resolution, the accurate measurement of whole cartilage tissue in clinical MRI could be utilized to detect differences between healthy and osteoarthritic cartilage after compression.

  15. Experimental measurements and theoretical simulations for neutron flux in self-serve facility of Dhruva reactor

    International Nuclear Information System (INIS)

    Rana, Y.S.; Mishra, Abhishek; Singh, Tej

    2016-06-01

    Dhruva is a 100 MW th tank type research reactor with natural metallic uranium as fuel and heavy water as coolant, moderator and reflector. The reactor is utilized for production of a large variety of radioisotopes for fulfilling growing demands of various applications in industrial, agricultural and medicinal sectors, and neutron beam research in condensed matter physics. The core consists of two on-power tray rods for radioisotope production and fifteen experimental beam holes for neutron beam research. Recently, a self-serve facility has also been commissioned in one of the through tubes in the reactor for carrying out short term irradiations. To get accurate information about neutron flux spectrum, measurements have been carried out in self-serve facility of Dhruva reactor. The present report describes measurement method, analysis technique and results. Theoretical estimations for neutron flux were also carried out and a comparison between theoretical and experimental results is made. (author)

  16. Measurement of ultra-high energy cosmic rays: An experimental summary and prospects

    Directory of Open Access Journals (Sweden)

    Fukushima M.

    2013-06-01

    Full Text Available Measurements of Ultra-High Energy Cosmic Rays achieved remarkable progress in the last 10 years. Physicists, gathered from around the world in the symposium UHECR-2012 held at CERN on February 13-16 2012, reported their most up-to-date observations, discussed the meaning of their findings, and identified remaining problems and future challenges in this field. This paper is a part of the symposium proceedings on the experimental summary and future prospects of the UHECR study.

  17. Experimental system using an active method for the measurement of low alpha emitter grades

    International Nuclear Information System (INIS)

    Bernard, P.; Cance, M.

    1986-06-01

    The diversity of waste produced in France, the limitations of passive neutron measurements, the new safety requirements in the field of low level waste disposal have induced us to develop active neutron techniques. Two experimental pulsed neutron interrogation systems are described giving a sensitivity lower than 10 mg Pu 239 in 200 l drums. This project is the result of a close cooperation between the CEA, SGN and SODERN

  18. Basic experimental preparation for the measurement of the stopping power of heavy ions in matter

    International Nuclear Information System (INIS)

    Carvalho Brito Brum, H. de.

    1976-02-01

    To measure the stopping power of heavy ions in solid matter one must develop both an experimental apparatus and a data analysis program. This thesis discusses these preparatory works and the methods to be employed. The design, building and testing of a scattering chamber with many detectors; the preparation of thin solid films, their analysis by electron diffraction and their thickness measurements; the testing of the electronic system; the calibration of the 4 MeV Van de Graaf accelerator at PUC/RJ; and the development of an original data analysis computer program are presented. (Author) [pt

  19. Experimental results on the MOX fuel. Study of the calculus/measures divergences

    International Nuclear Information System (INIS)

    Martin, S.

    1997-01-01

    For each nuclear plant unit restart, all safety criterion have to be respected. Various parameters as boron concentration, temperature coefficient, worth or power and activity distributions related to fuel assemblies, have to be calculated. To compute these parameters Framatome uses the neutronic channel Science. Before the validation they are compare to experimental measures. For UO 2 fuel the divergence calculus/measures are correct. But for MOX fuels the divergence worsening. This paper discusses tis divergence and research the origin. (A.L.B.)

  20. Theory and experimental study of biased charge collector for measuring HPIB

    International Nuclear Information System (INIS)

    He Xiaoping; Wang Haiyang; Sun Jianfeng; Yang Hailiang; Qiu Aici; Tang Junping; Li Jingya; Li Hongyu

    2004-01-01

    Structure of the biased charge collector for measuring HPIB (High-power ion beam) is introduced in this paper. The inner charge propagation process of HPIB in the biased charge collector was simulated with KARAT PIC code. The simulation results indicated that charge was neutralized but current was not neutralized in the biased charge collector. The influence of biased voltage and aperture diameter were also simulated. A -800V biased voltage can meet the requirement for measuring 500 keV HPIB, and this is consistent with the experimental results

  1. Sensitivity Measurement of Transmission Computer Tomography: thePreliminary Experimental Study

    International Nuclear Information System (INIS)

    Widodo, Chomsin-S; Sudjatmoko; Kusminarto; Agung-BS Utomo; Suparta, Gede B

    2000-01-01

    This paper reports result of preliminary experimental study onmeasurement method for sensitivity of a computed tomography (CT) scanner. ACT scanner has been build at the Department of Physics, FMIPA UGM and itsperformance based on its sensitivity was measured. The result showed that themeasurement method for sensitivity confirmed this method may be developedfurther as a measurement standard. Although the CT scanner developed has anumber of shortcoming, the analytical results from the sensitivitymeasurement suggest a number of reparations and improvements for the systemso that improved reconstructed CT images can be obtained. (author)

  2. An experimental set-up to measure Light Yield of Scintillating Fibres

    CERN Document Server

    Alfieri, C; Joram, C; Kenzie, M W

    2015-01-01

    In the context of the LHCb SciFi Tracker project, an experimental set up was designed and built to provide reliable and reproducible measurements of the light yield of scintillating fibres. This document describes the principle and technical realisation of the set-up. A few examples illustrate the operation and data analysis. In the first implementation of the set-up a photomultiplier tube with bialkali photocathode was used for the reading of the light from the fibres under test. In order to measure also green emitting fibres, the photomultiplier was replaced in January 2016 by a SiPM with higher sensitivity and larger spectral coverage1.

  3. An experimental applications of impedance measurements by spectral analysis to electrochemistry and corrosion

    International Nuclear Information System (INIS)

    Castro, E.B.; Vilche, J.R.; Milocco, R.H.

    1984-01-01

    An impedance measurement system based on the spectral analysis of excitation and response signals was implemented using a pseudo-random binary sequence in the generation of the electrical perturbation signal. The spectral density functions were estimated through finite Fourier transforms of the original time history records by fast computation of Fourier series. Experimental results obtained using the FFT algorithm in the developed impedance measurement system which covers a wide frequency range, 10 KHz >= f >= 1 mHz, are given both for dummy cells representing conventional electric circuits in electrochemistry and corrosion systems and for the Fe/acidic chloride solution interfaces under different polarization conditions. (C.L.B.) [pt

  4. An Effective Experimental Optimization Method for Wireless Power Transfer System Design Using Frequency Domain Measurement

    Directory of Open Access Journals (Sweden)

    Sangyeong Jeong

    2017-10-01

    Full Text Available This paper proposes an experimental optimization method for a wireless power transfer (WPT system. The power transfer characteristics of a WPT system with arbitrary loads and various types of coupling and compensation networks can be extracted by frequency domain measurements. The various performance parameters of the WPT system, such as input real/imaginary/apparent power, power factor, efficiency, output power and voltage gain, can be accurately extracted in a frequency domain by a single passive measurement. Subsequently, the design parameters can be efficiently tuned by separating the overall design steps into two parts. The extracted performance parameters of the WPT system were validated with time-domain experiments.

  5. Feasibility of reactivity worth measurements by perturbation method with Caliban and Silene experimental reactors

    Energy Technology Data Exchange (ETDEWEB)

    Casoli, Pierre; Authier, Nicolas [Commissariat a l' Energie Atomique, Centre d' Etudes de Valduc, 21120 Is-Sur-Tille (France)

    2008-07-01

    Reactivity worth measurements of material samples put in the central cavities of nuclear reactors allow to test cross section nuclear databases or to extract information about the critical masses of fissile elements. Such experiments have already been completed on the Caliban and Silene experimental reactors operated by the Criticality and Neutronics Research Laboratory of Valduc (CEA, France) using the perturbation measurement technique. Calculations have been performed to prepare future experiments on new materials, such as light elements, structure materials, fission products or actinides. (authors)

  6. Quantitative comparisons between experimentally measured 2-D carbon radiation and Monte Carlo impurity (MCI) code simulations

    International Nuclear Information System (INIS)

    Evans, T.E.; Leonard, A.W.; West, W.P.; Finkenthal, D.F.; Fenstermacher, M.E.; Porter, G.D.

    1998-08-01

    Experimentally measured carbon line emissions and total radiated power distributions from the DIII-D divertor and Scrape-Off Layer (SOL) are compared to those calculated with the Monte Carlo Impurity (MCI) model. A UEDGE background plasma is used in MCI with the Roth and Garcia-Rosales (RG-R) chemical sputtering model and/or one of six physical sputtering models. While results from these simulations do not reproduce all of the features seen in the experimentally measured radiation patterns, the total radiated power calculated in MCI is in relatively good agreement with that measured by the DIII-D bolometric system when the Smith78 physical sputtering model is coupled to RG-R chemical sputtering in an unaltered UEDGE plasma. Alternatively, MCI simulations done with UEDGE background ion temperatures along the divertor target plates adjusted to better match those measured in the experiment resulted in three physical sputtering models which when coupled to the RG-R model gave a total radiated power that was within 10% of measured value

  7. An experimental technique for the direct measurement of N2O5 reactivity on ambient particles

    Directory of Open Access Journals (Sweden)

    T. H. Bertram

    2009-06-01

    Full Text Available An experimental approach for the direct measurement of trace gas reactivity on ambient aerosol particles has been developed. The method utilizes a newly designed entrained aerosol flow reactor coupled to a custom-built chemical ionization mass spectrometer. The experimental method is described via application to the measurement of the N2O5 reaction probability, γ (N2O5. Laboratory investigations on well characterized aerosol particles show that measurements of γ (N2O5 observed with this technique are in agreement with previous observations, using conventional flow tube methods, to within ±20% at atmospherically relevant particle surface area concentrations (0–1000 μm2 cm−3. Uncertainty in the measured γ (N2O5 is discussed in the context of fluctuations in potential ambient biases (e.g., temperature, relative humidity and trace gas loadings. Under ambient operating conditions we estimate a single-point uncertainty in γ (N2O5 that ranges between ± (1.3×10-2 + 0.2×γ (N2O5, and ± (1.3×10-3 + 0.2×γ (N2O5 for particle surface area concentrations of 100 to 1000 μm2 cm−3, respectively. Examples from both laboratory investigations and field observations are included alongside discussion of future applications for the reactivity measurement and optimal deployment locations and conditions.

  8. Experimental study on reactivity measurement in thermal reactor by polarity correlation method

    International Nuclear Information System (INIS)

    Yasuda, Hideshi

    1977-11-01

    Experimental study on the polarity correlation method for measuring the reactivity of a thermal reactor, especially the one possessing long prompt neutron lifetime such as graphite on heavy water moderated core, is reported. The techniques of reactor kinetics experiment are briefly reviewed, which are classified in two groups, one characterized by artificial disturbance to a reactor and the other by natural fluctuation inherent in a reactor. The fluctuation phenomena of neutron count rate are explained using F. de Hoffman's stochastic method, and correlation functions for the neutron count rate fluctuation are shown. The experimental results by polarity correlation method applied to the β/l measurements in both graphite-moderated SHE core and light water-moderated JMTRC and JRR-4 cores, and also to the measurement of SHE shut down reactivity margin are presented. The measured values were in good agreement with those by a pulsed neutron method in the reactivity range from critical to -12 dollars. The conditional polarity correlation experiments in SHE at -20 cent and -100 cent are demonstrated. The prompt neutron decay constants agreed with those obtained by the polarity correlation experiments. The results of experiments measuring large negative reactivity of -52 dollars of SHE by pulsed neutron, rod drop and source multiplication methods are given. Also it is concluded that the polarity and conditional polarity correlation methods are sufficiently applicable to noise analysis of a low power thermal reactor with long prompt neutron lifetime. (Nakai, Y.)

  9. Modeling and experimental characterization of a new piezoelectric sensor for low-amplitude vibration measurement

    International Nuclear Information System (INIS)

    Hou, X Y; Koh, C G; Kuang, K S C; Lee, W H

    2017-01-01

    This paper investigates the capability of a novel piezoelectric sensor for low-frequency and low-amplitude vibration measurement. The proposed design effectively amplifies the input acceleration via two amplifying mechanisms and thus eliminates the use of the external charge amplifier or conditioning amplifier typically employed for measurement system. The sensor is also self-powered, i.e. no external power unit is required. Consequently, wiring and electrical insulation for on-site measurement are considerably simpler. In addition, the design also greatly reduces the interference from rotational motion which often accompanies the translational acceleration to be measured. An analytical model is developed based on a set of piezoelectric constitutive equations and beam theory. Closed-form expression is derived to correlate sensor geometry and material properties with its dynamic performance. Experimental calibration is then carried out to validate the analytical model. After calibration, experiments are carried out to check the feasibility of the new sensor in structural vibration detection. From experimental results, it is concluded that the proposed sensor is suitable for measuring low-frequency and low-amplitude vibrations. (paper)

  10. Histologic processing artifacts and inter-pathologist variation in measurement of inked margins of canine mast cell tumors.

    Science.gov (United States)

    Kiser, Patti K; Löhr, Christiane V; Meritet, Danielle; Spagnoli, Sean T; Milovancev, Milan; Russell, Duncan S

    2018-05-01

    Although quantitative assessment of margins is recommended for describing excision of cutaneous malignancies, there is poor understanding of limitations associated with this technique. We described and quantified histologic artifacts in inked margins and determined the association between artifacts and variance in histologic tumor-free margin (HTFM) measurements based on a novel grading scheme applied to 50 sections of normal canine skin and 56 radial margins taken from 15 different canine mast cell tumors (MCTs). Three broad categories of artifact were 1) tissue deformation at inked edges, 2) ink-associated artifacts, and 3) sectioning-associated artifacts. The most common artifacts in MCT margins were ink-associated artifacts, specifically ink absent from an edge (mean prevalence: 50%) and inappropriate ink coloring (mean: 45%). The prevalence of other artifacts in MCT skin was 4-50%. In MCT margins, frequency-adjusted kappa statistics found fair or better inter-rater reliability for 9 of 10 artifacts; intra-rater reliability was moderate or better in 9 of 10 artifacts. Digital HTFM measurements by 5 blinded pathologists had a median standard deviation (SD) of 1.9 mm (interquartile range: 0.8-3.6 mm; range: 0-6.2 mm). Intraclass correlation coefficients demonstrated good inter-pathologist reliability in HTFM measurement (κ = 0.81). Spearman rank correlation coefficients found negligible correlation between artifacts and HTFM SDs ( r ≤ 0.3). These data confirm that although histologic artifacts commonly occur in inked margin specimens, artifacts are not meaningfully associated with variation in HTFM measurements. Investigators can use the grading scheme presented herein to identify artifacts associated with tissue processing.

  11. Measurement of ventilation- and perfusion-mediated cooling during laser ablation in ex vivo human lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vietze, Andrea, E-mail: anvie@gmx.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Koch, Franziska, E-mail: franzi_koch@hotmail.com [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Laskowski, Ulrich, E-mail: ulrich.laskowski@klinikum-luedenscheid.de [Department of Vascular and Thoracic Surgery, Klinikum Luedenscheid, Paulmannshoeher Strasse 14, 58515 Luedenscheid (Germany); Linder, Albert, E-mail: albert.linder@klinikum-bremen-ost.de [Department of Thoracic Surgery, Klinikum Bremen-Ost, Zuericher Strasse 40, 28325 Bremen (Germany); Hosten, Norbert, E-mail: hosten@uni-greifswald.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany)

    2011-11-15

    Purpose: Perfusion-mediated tissue cooling has often been described in the literature for thermal ablation therapies of liver tumors. The objective of this study was to investigate the cooling effects of both perfusion and ventilation during laser ablation of lung malignancies. Materials and methods: An ex vivo lung model was used to maintain near physiological conditions for the specimens. Fourteen human lung lobes containing only primary lung tumors (non-small cell lung cancer) were used. Laser ablation was carried out using a Nd:YAG laser with a wavelength of 1064 nm and laser fibers with 30 mm diffusing tips. Continuous invasive temperature measurement in 10 mm distance from the laser fiber was performed. Laser power was increased at 2 W increments starting at 10 W up to a maximum power of 12-20 W until a temperature plateau around 60 deg. C was reached at one sensor. Ventilation and perfusion were discontinued for 6 min each to assess their effects on temperature development. Results: The experiments lead to 25 usable temperature profiles. A significant temperature increase was observed for both discontinued ventilation and perfusion. In 6 min without perfusion, the temperature rose about 5.5 deg. C (mean value, P < 0.05); without ventilation it increased about 7.0 deg. C (mean value, P < 0.05). Conclusion: Ventilation- and perfusion-mediated tissue cooling are significant influencing factors on temperature development during thermal ablation. They should be taken into account during the planning and preparation of minimally invasive lung tumor treatment in order to achieve complete ablation.

  12. Comparison of theoretical estimates and experimental measurements of fatigue crack growth under severe thermal shock conditions (part one - experimental observations)

    International Nuclear Information System (INIS)

    Marsh, D.; Green, D.; Parker, R.

    1984-01-01

    This paper reports the results of an experiment in which a severe thermal cycle comprising of alternate upshocks and downshocks has been applied to an axisymmetric feature with an internal, partial penetration weld and crevice. The direction of cracking and crack growth rate were observed experimentally and detailed records made of the thermal cycle. A second part to the paper, reported separately, compares a linear elastic fracture mechanics assessment of the cracking to the experimental observations

  13. Design of an experimental device dedicated to the measurement of spallation reactions; Mise au point d'un dispositif experimental pour des mesures exclusives des reactions de spallation

    Energy Technology Data Exchange (ETDEWEB)

    Lafriakh, A

    2005-12-15

    Spallation mechanisms are not yet completely understood, especially because of the difficulty of experimentally disentangling the effects of the different steps of the reaction. In order to understand these mechanisms, we have developed a new experimental device able to perform inclusive measurements. We propose a detection system based on a combination of ionization chambers and proportional counters and on a wall of plastic scintillators to measure light charged particles. In particular the detection of light charged particles is described in detail. In order to validate our device, we have compared our preliminary results obtained on the Fe{sup 56} + p system at 1 GeV/u with inclusive measurements previously obtained at the FRS spectrometer of the GSI facility. A comparison of charge differential cross section shows reasonable agreement. However, our new device allowed extension of those measurements down to Z = 1 and Z = 2. These cross sections are important for material damage studies. Taking into account our error brackets, the evolution of mean longitudinal velocities with respect to residue masses is comparable to that obtained at the FRS. These first results, although preliminary, allow us to validate our experimental device. It is now possible to exploit the strong points of our exclusive measurements, namely correlations between different measured observables. Finally, experimental problems encountered will be taken into account in the future experimental programs, in order to ensure the best measurements conditions.

  14. Stochastic models for tumoral growth

    OpenAIRE

    Escudero, Carlos

    2006-01-01

    Strong experimental evidence has indicated that tumor growth belongs to the molecular beam epitaxy universality class. This type of growth is characterized by the constraint of cell proliferation to the tumor border, and surface diffusion of cells at the growing edge. Tumor growth is thus conceived as a competition for space between the tumor and the host, and cell diffusion at the tumor border is an optimal strategy adopted for minimizing the pressure and helping tumor development. Two stoch...

  15. Bone tumor

    Science.gov (United States)

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor; Bone tumor - benign ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  16. A non-invasive experimental approach for surface temperature measurements on semi-crystalline thermoplastics

    Science.gov (United States)

    Boztepe, Sinan; Gilblas, Remi; de Almeida, Olivier; Le Maoult, Yannick; Schmidt, Fabrice

    2017-10-01

    Most of the thermoforming processes of thermoplastic polymers and their composites are performed adopting a combined heating and forming stages at which a precursor is heated prior to the forming. This step is done in order to improve formability by softening the thermoplastic polymer. Due to low thermal conductivity and semi-transparency of polymers, infrared (IR) heating is widely used for thermoforming of such materials. Predictive radiation heat transfer models for temperature distributions are therefore critical for optimizations of thermoforming process. One of the key challenges is to build a predictive model including the physical background of radiation heat transfer phenomenon in semi-crystalline thermoplastics as their microcrystalline structure introduces an optically heterogeneous medium. In addition, the accuracy of a predictive model is required to be validated experimentally where IR thermography is one of the suitable methods for such a validation as it provides a non-invasive, full-field surface temperature measurement. Although IR cameras provide a non-invasive measurement, a key issue for obtaining a reliable measurement depends on the optical characteristics of a heated material and the operating spectral band of IR camera. It is desired that the surface of a material to be measured has a spectral band where the material behaves opaque and an employed IR camera operates in the corresponding band. In this study, the optical characteristics of the PO-based polymer are discussed and, an experimental approach is proposed in order to measure the surface temperature of the PO-based polymer via IR thermography. The preliminary analyses showed that IR thermographic measurements may not be simply performed on PO-based polymers and require a correction method as their semi-transparent medium introduce a challenge to obtain reliable surface temperature measurements.

  17. Experimental assessment for instantaneous temperature and heat flux measurements under Diesel motored engine conditions

    International Nuclear Information System (INIS)

    Torregrosa, A.J.; Bermúdez, V.; Olmeda, P.; Fygueroa, O.

    2012-01-01

    Higlights: ► We measured in-cylinder wall heat fluxes. ► We examine the effects of different engine parameters. ► Increasing air mass flow increase heat fluxes. ► The effect of engine speed can be masked by the effect of volumetric efficiency. ► Differences among the different walls have been found. - Abstract: The main goal of this work is to validate an innovative experimental facility and to establish a methodology to evaluate the influence of some of the engine parameters on local engine heat transfer behaviour under motored steady-state conditions. Instantaneous temperature measurements have been performed in order to estimate heat fluxes on a modified Diesel single cylinder combustion chamber. This study was divided into two main parts. The first one was the design and setting on of an experimental bench to reproduce Diesel conditions and perform local-instantaneous temperature measurements along the walls of the combustion chamber by means of fast response thermocouples. The second one was the development of a procedure for temperature signal treatment and local heat flux calculation based on one-dimensional Fourier analysis. A thermodynamic diagnosis model has been employed to characterise the modified engine with the new designed chamber. As a result of the measured data coherent findings have been obtained in order to understand local behaviour of heat transfer in an internal combustion engine, and the influence of engine parameters on local instantaneous temperature and heat flux, have been analysed.

  18. Numerical Simulations and Experimental Measurements of Scale-Model Horizontal Axis Hydrokinetic Turbines (HAHT) Arrays

    Science.gov (United States)

    Javaherchi, Teymour; Stelzenmuller, Nick; Seydel, Joseph; Aliseda, Alberto

    2014-11-01

    The performance, turbulent wake evolution and interaction of multiple Horizontal Axis Hydrokinetic Turbines (HAHT) is analyzed in a 45:1 scale model setup. We combine experimental measurements with different RANS-based computational simulations that model the turbines with sliding-mesh, rotating reference frame and blame element theory strategies. The influence of array spacing and Tip Speed Ratio on performance and wake velocity structure is investigated in three different array configurations: Two coaxial turbines at different downstream spacing (5d to 14d), Three coaxial turbines with 5d and 7d downstream spacing, and Three turbines with lateral offset (0.5d) and downstream spacing (5d & 7d). Comparison with experimental measurements provides insights into the dynamics of HAHT arrays, and by extension to closely packed HAWT arrays. The experimental validation process also highlights the influence of the closure model used (k- ω SST and k- ɛ) and the flow Reynolds number (Re=40,000 to 100,000) on the computational predictions of devices' performance and characteristics of the flow field inside the above-mentioned arrays, establishing the strengths and limitations of existing numerical models for use in industrially-relevant settings (computational cost and time). Supported by DOE through the National Northwest Marine Renewable Energy Center (NNMREC).

  19. Experimental measurement and modeling of snow accumulation and snowmelt in a mountain microcatchment

    Science.gov (United States)

    Danko, Michal; Krajčí, Pavel; Hlavčo, Jozef; Kostka, Zdeněk; Holko, Ladislav

    2016-04-01

    Fieldwork is a very useful source of data in all geosciences. This naturally applies also to the snow hydrology. Snow accumulation and snowmelt are spatially very heterogeneous especially in non-forested, mountain environments. Direct field measurements provide the most accurate information about it. Quantification and understanding of processes, that cause these spatial differences are crucial in prediction and modelling of runoff volumes in spring snowmelt period. This study presents possibilities of detailed measurement and modeling of snow cover characteristics in a mountain experimental microcatchment located in northern part of Slovakia in Western Tatra mountains. Catchment area is 0.059 km2 and mean altitude is 1500 m a.s.l. Measurement network consists of 27 snow poles, 3 small snow lysimeters, discharge measurement device and standard automatic weather station. Snow depth and snow water equivalent (SWE) were measured twice a month near the snow poles. These measurements were used to estimate spatial differences in accumulation of SWE. Snowmelt outflow was measured by small snow lysimeters. Measurements were performed in winter 2014/2015. Snow water equivalent variability was very high in such a small area. Differences between particular measuring points reached 600 mm in time of maximum SWE. The results indicated good performance of a snow lysimeter in case of snowmelt timing identification. Increase of snowmelt measured by the snow lysimeter had the same timing as increase in discharge at catchment's outlet and the same timing as the increase in air temperature above the freezing point. Measured data were afterwards used in distributed rainfall-runoff model MIKE-SHE. Several methods were used for spatial distribution of precipitation and snow water equivalent. The model was able to simulate snow water equivalent and snowmelt timing in daily step reasonably well. Simulated discharges were slightly overestimated in later spring.

  20. A dual tracer ratio method for comparative emission measurements in an experimental dairy housing

    Science.gov (United States)

    Mohn, Joachim; Zeyer, Kerstin; Keck, Margret; Keller, Markus; Zähner, Michael; Poteko, Jernej; Emmenegger, Lukas; Schrade, Sabine

    2018-04-01

    Agriculture, and in particular dairy farming, is an important source of ammonia (NH3) and non-carbon dioxide greenhouse gas (GHG) emissions. This calls for the development and quantification of effective mitigation strategies. Our study presents the implementation of a dual tracer ratio method in a novel experimental dairy housing with two identical, but spatially separated housing areas. Modular design and flexible floor elements allow the assessment of structural, process engineering and organisational abatement measures at practical scale. Thereby, the emission reduction potential of specific abatement measures can be quantified in relation to a reference system. Emissions in the naturally ventilated housing are determined by continuous dosing of two artificial tracers (sulphur hexafluoride SF6, trifluoromethylsulphur pentafluoride SF5CF3) and their real-time detection in the ppt range with an optimized GC-ECD method. The two tracers are dosed into different experimental sections, which enables the independent assessment of both housing areas. Mass flow emissions of NH3 and GHGs are quantified by areal dosing of tracer gases and multipoint sampling as well as real-time analysis of both tracer and target gases. Validation experiments demonstrate that the technique is suitable for both areal and point emission sources and achieves an uncertainty of less than 10% for the mass emissions of NH3, methane (CH4) and carbon dioxide (CO2), which is superior to other currently available methods. Comparative emission measurements in this experimental dairy housing will provide reliable, currently unavailable information on emissions for Swiss dairy farming and demonstrate the reduction potential of mitigation measures for NH3, GHGs and potentially other pollutants.

  1. Experimentally measuring a quantum state by the Heisenberg exchange interaction in a single apparatus

    International Nuclear Information System (INIS)

    Peng Xinhua; Du Jiangfeng; Suter, D.

    2005-01-01

    Full text: Quantum information processing requires the effective measurement of quantum states. An important method, called quantum state tomography, needs measuring a complete set of observables on the measured system to determine its unknown quantum state ρ. The measurement involves certain noncommuting observables as a result of Bohr's complementarity. Very recently, Allahverdyan et al. proposed a new method in which the unknown quantum state r is determined by measuring a set of commuting observables in the price of a controlled interaction with an auxiliary system. If both systems S and A are spins, their z components (σ z ) can be chosen to measure after some specific Heisenberg exchange interaction. We study in detail a general Heisenberg XYZ model for a two-qubit system and present two classes of special Heisenberg interactions which can serve as the controlled interaction in Allahverdyan's scheme when the state of the auxiliary system A is initially completely disordered. Using the nuclear magnetic resonance techniques, the measurement scheme in a single apparatus has been experimentally demonstrated by designing the quantum circuit to simulate the Heisenberg exchange interaction. (author)

  2. Using the analysis of stress waves to build research for experimentation on ultrasonic film measurement

    Science.gov (United States)

    Chang, Shi-Shing; Wu, John H.

    1993-09-01

    After the 2th world war, although the application of ultrasonic wave in industries is becoming more and more popular. But due to the restriction of the precise equivelent , experimental method and the support of the basic theoremsetc. Ultrasonic wave is not applied in precise measurement. Nowadays due to many conditions - the improvement in the production technic, the precise of the equivelent, causes to increase the application of ultrasonic wave. But it's still limited due to the lack of measurement and analysis theorem. In this paper, first we caculate translation of the stress wave (elastic wave) in material for the free surface of material by a normal impulse load. as the theorem analysis base in real application. It is applied to an experiment of film measurement. We can find the partical motion in material and the arriving time of wave front. Then we can estimate the thickness of layers and can prove the actual condition with the result of experiment. This resarch is not only in the theoretical investigation but also in setting overall the measurement system, and excutes the following three experiments: the thickness measurement of two layers, the thickness measurement of film material. the thickness measurement of air propagation. About the data processing, we relied on the frequency analysis to evalute the time difference of two overlapped ultrasonic wave signal. in the meanwhile. we also designed several computer programs to assist the sonic wave identification and signal analysis.

  3. Intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner-air density of tumors.

    Science.gov (United States)

    Wang, Qingle; Zhang, Zhiyong; Shan, Fei; Shi, Yuxin; Xing, Wei; Shi, Liangrong; Zhang, Xingwei

    2017-09-01

    This study was conducted to assess intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary lung cancer, were divided into two groups: (i) nodules (diameter ≤3 cm) and masses (diameter >3 cm) by size, and (ii) tumors with and without air density. Pulmonary flow, bronchial flow, and pulmonary index were measured in each group. Intra-observer and inter-observer agreements for measurement were assessed using intraclass correlation coefficient, within-subject coefficient of variation, and Bland-Altman analysis. In all lung cancers, the reproducibility coefficient for intra-observer agreement (range 26.1-38.3%) was superior to inter-observer agreement (range 38.1-81.2%). Further analysis revealed lower agreements for nodules compared to masses. Additionally, inner-air density reduced both agreements for lung cancer. The intra-observer agreement for measuring lung cancer DCTP was satisfied, while the inter-observer agreement was limited. The effects of tumoral size and inner-air density to agreements, especially between two observers, should be emphasized. In future, an automatic computer-aided segment of perfusion value of the tumor should be developed. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  4. Characterisation of large area THGEMs and experimental measurement of the Townsend coefficients for CF4

    Science.gov (United States)

    Burns, J.; Crane, T.; Ezeribe, A. C.; Grove, C. L.; Lynch, W.; Scarff, A.; Spooner, N. J. C.; Steer, C.

    2017-10-01

    Whilst the performance of small THGEMs is well known, here we consider the challenges in scaling these up to large area charge readouts. We first verify the expected gain of larger THGEMs by reporting experimental Townsend coefficients for a 10 cm diameter THGEM in low-pressure CF4. Large area 50 cm by 50 cm THGEMs were sourced from a commercial PCB supplier and geometrical imperfections were observed which we quantified using an optical camera setup. The large area THGEMs were experimentally characterised at Boulby Underground Laboratory through a series of gain calibrations and alpha spectrum measurements. ANSYS, Magboltz and Garfield++ simulations of the design of a TPC based on the large area THGEMs are presented. We also consider their implications for directional dark matter research and potential applications within nuclear security.

  5. Experimental measurements and numerical simulation of permittivity and permeability of Teflon in X band

    Directory of Open Access Journals (Sweden)

    Adriano Luiz de Paula

    2011-01-01

    Full Text Available Recognizing the importance of an adequate characterization of radar absorbing materials, and consequently their development, the present study aims to contribute for the establishment and validation of experimental determination and numerical simulation of electromagnetic materials complex permittivity and permeability, using a Teflon® sample. The present paper branches out into two related topics. The first one is concerned about the implementation of a computational modeling to predict the behavior of electromagnetic materials in confined environment by using electromagnetic three-dimensional simulation. The second topic re-examines the Nicolson-Ross-Weir mathematical model to retrieve the constitutive parameters (complex permittivity and permeability of a homogeneous sample (Teflon®, from scattering coefficient measurements. The experimental and simulated results show a good convergence that guarantees the application of the used methodologies for the characterization of different radar absorbing materials samples.

  6. Experimental measurement of the 12C+16O fusion cross sections at astrophysical energies

    Science.gov (United States)

    Fang, X.; Tan, W. P.; Beard, M.; deBoer, R. J.; Gilardy, G.; Jung, H.; Liu, Q.; Lyons, S.; Robertson, D.; Setoodehnia, K.; Seymour, C.; Stech, E.; Vande Kolk, B.; Wiescher, M.; de Souza, R.; Hudan, S.; Singh, V.; Tang, X. D.; Uberseder, E.

    2018-05-01

    The total cross sections of the 12C+16O fusion have been experimentally determined at low energies to investigate the role of this reaction during late stellar evolution burning phases. A high-intensity oxygen beam was produced by the 5MV pelletron accelerator at the University of Notre Dame impinging on a thick ultra-pure graphite target. Protons and γ-rays were measured simultaneously in the center-of-mass energy range from 3.64 to 5.01 MeV, using strip silicon and HPGe detectors. Statistical model calculations were employed to interpret the experimental results. A new broad resonance-like structure is observed for the 12C+16O reaction, and a decreasing trend of its S-factor towards low energies is found.

  7. Measurements and Experimental Database Review for Laminar Flame Speed Premixed Ch4/Air Flames

    Science.gov (United States)

    Zubrilin, I. A.; Matveev, S. S.; Matveev, S. G.; Idrisov, D. V.

    2018-01-01

    Laminar flame speed (SL ) of CH4 was determined at atmospheric pressure and initial gas temperatures in range from 298 to 358 K. The heat flux method was employed to measure the flame speed in non-stretched flames. The kinetic mechanism GRI 3.0 [1] were used to simulate SL . The measurements were compared with available literature results. The data determined with the heat flux method agree with some previous burner measurements and disagree with the data from some vessel closed method and counterflow method. The GRI 3.0 mechanism was able to reproduce the present experiments. Laminar flame speed was determined at pressures range from of 1 to 20 atmospheres through mechanism GRI 3.0. Based on experimental data and calculations was obtained SL dependence on pressure and temperature. The resulting of dependence recommended use during the numerical simulation of methane combustion.

  8. Experimental Characterization of Ultra-Wideband Channel Parameter Measurements in an Underground Mine

    Directory of Open Access Journals (Sweden)

    B. Nkakanou

    2011-01-01

    Full Text Available Experimental results for an ultra-wideband (UWB channel parameters in an underground mining environment over a frequency range of 3 GHz to 10 GHz are reported. The measurements were taken both in LOS and NLOS cases in two different size mine galleries. In the NLOS case, results were acquired for different corridor obstruction angles. The results were obtained during an extensive measurement campaign in the UWB frequency, and the measurement procedure allows both the large- and small-scale parameters such as the path loss exponent, coherence bandwidth, and so forth, to be quantified. The capacity of the UWB channel as a function of the physical depth of the mine gallery has also been recorded for comparison purposes.

  9. Experimental study on two-dimensional film flow with local measurement methods

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jin-Hwa, E-mail: evo03@snu.ac.kr [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Cho, Hyoung-Kyu [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Kim, Seok [Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Euh, Dong-Jin, E-mail: djeuh@kaeri.re.kr [Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Park, Goon-Cherl [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of)

    2015-12-01

    Highlights: • An experimental study on the two-dimensional film flow with lateral air injection was performed. • The ultrasonic thickness gauge was used to measure the local liquid film thickness. • The depth-averaged PIV (Particle Image Velocimetry) method was applied to measure the local liquid film velocity. • The uncertainty of the depth-averaged PIV was quantified with a validation experiment. • Characteristics of two-dimensional film flow were classified following the four different flow patterns. - Abstract: In an accident condition of a nuclear reactor, multidimensional two-phase flows may occur in the reactor vessel downcomer and reactor core. Therefore, those have been regarded as important issues for an advanced thermal-hydraulic safety analysis. In particular, the multi-dimensional two-phase flow in the upper downcomer during the reflood phase of large break loss of coolant accident appears with an interaction between a downward liquid and a transverse gas flow, which determines the bypass flow rate of the emergency core coolant and subsequently, the reflood coolant flow rate. At present, some thermal-hydraulic analysis codes incorporate multidimensional modules for the nuclear reactor safety analysis. However, their prediction capability for the two-phase cross flow in the upper downcomer has not been validated sufficiently against experimental data based on local measurements. For this reason, an experimental study was carried out for the two-phase cross flow to clarify the hydraulic phenomenon and provide local measurement data for the validation of the computational tools. The experiment was performed in a 1/10 scale unfolded downcomer of Advanced Power Reactor 1400 (APR1400). Pitot tubes, a depth-averaged PIV method and ultrasonic thickness gauge were applied for local measurement of the air velocity, the liquid film velocity and the liquid film thickness, respectively. The uncertainty of the depth-averaged PIV method for the averaged

  10. Experimental study on two-dimensional film flow with local measurement methods

    International Nuclear Information System (INIS)

    Yang, Jin-Hwa; Cho, Hyoung-Kyu; Kim, Seok; Euh, Dong-Jin; Park, Goon-Cherl

    2015-01-01

    Highlights: • An experimental study on the two-dimensional film flow with lateral air injection was performed. • The ultrasonic thickness gauge was used to measure the local liquid film thickness. • The depth-averaged PIV (Particle Image Velocimetry) method was applied to measure the local liquid film velocity. • The uncertainty of the depth-averaged PIV was quantified with a validation experiment. • Characteristics of two-dimensional film flow were classified following the four different flow patterns. - Abstract: In an accident condition of a nuclear reactor, multidimensional two-phase flows may occur in the reactor vessel downcomer and reactor core. Therefore, those have been regarded as important issues for an advanced thermal-hydraulic safety analysis. In particular, the multi-dimensional two-phase flow in the upper downcomer during the reflood phase of large break loss of coolant accident appears with an interaction between a downward liquid and a transverse gas flow, which determines the bypass flow rate of the emergency core coolant and subsequently, the reflood coolant flow rate. At present, some thermal-hydraulic analysis codes incorporate multidimensional modules for the nuclear reactor safety analysis. However, their prediction capability for the two-phase cross flow in the upper downcomer has not been validated sufficiently against experimental data based on local measurements. For this reason, an experimental study was carried out for the two-phase cross flow to clarify the hydraulic phenomenon and provide local measurement data for the validation of the computational tools. The experiment was performed in a 1/10 scale unfolded downcomer of Advanced Power Reactor 1400 (APR1400). Pitot tubes, a depth-averaged PIV method and ultrasonic thickness gauge were applied for local measurement of the air velocity, the liquid film velocity and the liquid film thickness, respectively. The uncertainty of the depth-averaged PIV method for the averaged

  11. New experimental device for high-temperature normal spectral emissivity measurements of coatings

    International Nuclear Information System (INIS)

    Honnerová, Petra; Martan, Jiří; Kučera, Martin; Honner, Milan; Hameury, Jacques

    2014-01-01

    A new experimental device for normal spectral emissivity measurements of coatings in the infrared spectral range from 1.38 μm to 26 μm and in the temperature range from 550 K to 1250 K is presented. A Fourier transform infrared spectrometer (FTIR) is used for the detection of sample and blackbody spectral radiation. Sample heating is achieved by a fiber laser with a scanning head. Surface temperature is measured by two methods. The first method uses an infrared camera and a reference coating with known effective emissivity, the second method is based on the combination of Christiansen wavelength with contact and noncontact surface temperature measurement. Application of the method is shown on the example of a high-temperature high-emissivity coating. Experimental results obtained with this apparatus are compared with the results performed by a direct method of Laboratoire National d’Essais (LNE) in France. The differences in the spectra are analyzed. (paper)

  12. Calibration of a gamma spectrometer for measuring natural radioactivity. Experimental measurements and modeling by Monte-Carlo methods

    International Nuclear Information System (INIS)

    Courtine, Fabien

    2007-01-01

    The thesis proceeded in the context of dating by thermoluminescence. This method requires laboratory measurements of the natural radioactivity. For that purpose, we have been using a germanium spectrometer. To refine the calibration of this one, we modelled it by using a Monte-Carlo computer code: Geant4. We developed a geometrical model which takes into account the presence of inactive zones and zones of poor charge-collection within the germanium crystal. The parameters of the model were adjusted by comparison with experimental results obtained with a source of 137 Cs. It appeared that the form of the inactive zones is less simple than is presented in the specialized literature. This model was widened to the case of a more complex source, with cascade effect and angular correlations between photons: the 60 Co. Lastly, applied to extended sources, it gave correct results and allowed us to validate the simulation of matrix effect. (author)

  13. A novel full-field experimental method to measure the local compressibility of gas diffusion media

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Yeh-Hung; Li, Yongqiang [Electrochemical Energy Research Lab, GM R and D, Honeoye Falls, NY 14472 (United States); Rock, Jeffrey A. [GM Powertrain, Honeoye Falls, NY 14472 (United States)

    2010-05-15

    The gas diffusion medium (GDM) in a proton exchange membrane (PEM) fuel cell needs to simultaneously satisfy the requirements of transporting reactant gases, removing product water, conducting electrons and heat, and providing mechanical support to the membrane electrode assembly (MEA). Concerning the localized over-compression which may force carbon fibers and other conductive debris into the membrane to cause fuel cell failure by electronically shorting through the membrane, we have developed a novel full-field experimental method to measure the local thickness and compressibility of GDM. Applying a uniform air pressure upon a thin polyimide film bonded on the top surface of the GDM with support from the bottom by a flat metal substrate and measuring the thickness change using the 3-D digital image correlation technique with an out-of-plane displacement resolution less than 0.5 {mu}m, we have determined the local thickness and compressive stress/strain behavior in the GDM. Using the local thickness and compressibility data over an area of 11.2 mm x 11.2 mm, we numerically construct the nominal compressive response of a commercial Toray trademark TGP-H-060 based GDM subjected to compression by flat platens. Good agreement in the nominal stress/strain curves from the numerical construction and direct experimental flat-platen measurement confirms the validity of the methodology proposed in this article. The result shows that a nominal pressure of 1.4 MPa compressed between two flat platens can introduce localized compressive stress concentration of more than 3 MPa in up to 1% of the total area at various locations from several hundred micrometers to 1 mm in diameter. We believe that this full-field experimental method can be useful in GDM material and process development to reduce the local hard spots and help to mitigate the membrane shorting failure in PEM fuel cells. (author)

  14. A novel full-field experimental method to measure the local compressibility of gas diffusion media

    Science.gov (United States)

    Lai, Yeh-Hung; Li, Yongqiang; Rock, Jeffrey A.

    The gas diffusion medium (GDM) in a proton exchange membrane (PEM) fuel cell needs to simultaneously satisfy the requirements of transporting reactant gases, removing product water, conducting electrons and heat, and providing mechanical support to the membrane electrode assembly (MEA). Concerning the localized over-compression which may force carbon fibers and other conductive debris into the membrane to cause fuel cell failure by electronically shorting through the membrane, we have developed a novel full-field experimental method to measure the local thickness and compressibility of GDM. Applying a uniform air pressure upon a thin polyimide film bonded on the top surface of the GDM with support from the bottom by a flat metal substrate and measuring the thickness change using the 3-D digital image correlation technique with an out-of-plane displacement resolution less than 0.5 μm, we have determined the local thickness and compressive stress/strain behavior in the GDM. Using the local thickness and compressibility data over an area of 11.2 mm × 11.2 mm, we numerically construct the nominal compressive response of a commercial Toray™ TGP-H-060 based GDM subjected to compression by flat platens. Good agreement in the nominal stress/strain curves from the numerical construction and direct experimental flat-platen measurement confirms the validity of the methodology proposed in this article. The result shows that a nominal pressure of 1.4 MPa compressed between two flat platens can introduce localized compressive stress concentration of more than 3 MPa in up to 1% of the total area at various locations from several hundred micrometers to 1 mm in diameter. We believe that this full-field experimental method can be useful in GDM material and process development to reduce the local hard spots and help to mitigate the membrane shorting failure in PEM fuel cells.

  15. Modeling of a pitching and plunging airfoil using experimental flow field and load measurements

    Science.gov (United States)

    Troshin, Victor; Seifert, Avraham

    2018-01-01

    The main goal of the current paper is to outline a low-order modeling procedure of a heaving airfoil in a still fluid using experimental measurements. Due to its relative simplicity, the proposed procedure is applicable for the analysis of flow fields within complex and unsteady geometries and it is suitable for analyzing the data obtained by experimentation. Currently, this procedure is used to model and predict the flow field evolution using a small number of low profile load sensors and flow field measurements. A time delay neural network is used to estimate the flow field. The neural network estimates the amplitudes of the most energetic modes using four sensory inputs. The modes are calculated using proper orthogonal decomposition of the flow field data obtained experimentally by time-resolved, phase-locked particle imaging velocimetry. To permit the use of proper orthogonal decomposition, the measured flow field is mapped onto a stationary domain using volume preserving transformation. The analysis performed by the model showed good estimation quality within the parameter range used in the training procedure. However, the performance deteriorates for cases out of this range. This situation indicates that, to improve the robustness of the model, both the decomposition and the training data sets must be diverse in terms of input parameter space. In addition, the results suggest that the property of volume preservation of the mapping does not affect the model quality as long as the model is not based on the Galerkin approximation. Thus, it may be relaxed for cases with more complex geometry and kinematics.

  16. Geometrical Comparison Measures for Tumor Delineation, what do they mean for the Actual Dosis Plan?

    DEFF Research Database (Denmark)

    Hollensen, Christian; Persson, G.; Højgaard, L.

    2012-01-01

    Purpose/Objective: Gross tumour volume (GTV) delineation is central for radiotherapy planning. It provides the basis of the clinical target volume and finally the planning target volume (PTV) which is used for dose optimization. GTV delineations are prone to intermethod and inter......observer variation. In clinical studies this variation is commonly represented by geometrical volume comparison measures (GVCMs) as volume assessment, centre of mass and overlap. The correlation between these measures and the radiotherapy plan are however unclear. The aim of the present study is to investigate...... the correlation between GVCMs and the radiotherapy plans of patients with peripheral lung tumours. Materials and Methods: Peripheral lung tumours of 10 patients referred for stereotactic body radiotherapy in 2008 were delineated by 3 radiologists and 3 oncologists. From these GTV delineations 6 different...

  17. Measurement with SR-0 experimental modules of the SPHINX nuclear transmutation system. Variants 2008

    International Nuclear Information System (INIS)

    Rypar, Vojtech; Juricek, Vlastimil; Svadlenkova, Marie; Heraltova, Lenka; Viererbl, Ladislav; Lahodova, Zdena

    2008-12-01

    Experiments were performed with two LR-0 rector core arrangements and 3 variants of SR-0 insertion modules with a view to establishing the critical parameters of the reactor cores for the 3 module variants comprising different materials and different numbers of LR-0 fuel pins. The effect of the materials on the photon dose distribution and, on the axial and radial neutron field distributions (via 140 Ba and 140 La activities) was examined and the reaction rate distribution of activation foils inside the experimental module was measured

  18. Optical waveguiding and applied photonics technological aspects, experimental issue approaches and measurements

    CERN Document Server

    Massaro, Alessandro

    2012-01-01

    Optoelectronics--technology based on applications light such as micro/nano quantum electronics, photonic devices, laser for measurements and detection--has become an important field of research. Many applications and physical problems concerning optoelectronics are analyzed in Optical Waveguiding and Applied Photonics.The book is organized in order to explain how to implement innovative sensors starting from basic physical principles. Applications such as cavity resonance, filtering, tactile sensors, robotic sensor, oil spill detection, small antennas and experimental setups using lasers are a

  19. The Experimental Measurement of Aerodynamic Heating About Complex Shapes at Supersonic Mach Numbers

    Science.gov (United States)

    Neumann, Richard D.; Freeman, Delma C.

    2011-01-01

    In 2008 a wind tunnel test program was implemented to update the experimental data available for predicting protuberance heating at supersonic Mach numbers. For this test the Langley Unitary Wind Tunnel was also used. The significant differences for this current test were the advances in the state-of-the-art in model design, fabrication techniques, instrumentation and data acquisition capabilities. This current paper provides a focused discussion of the results of an in depth analysis of unique measurements of recovery temperature obtained during the test.

  20. Experimental study on active specific immunotherapy utilizing the immunotherapy utilizing the immune reaction of low-dose irradiated tumor tissue, 3

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Imanaka, Kazufumi; Gose, Kyuhei; Imajo, Yoshinari; Kimura, Shuji

    1982-01-01

    We have already demonstrated the remarkable effect of the active specific immunotherapy utilizing tumor cells and infiltrating lymphocytes prepared from a low-dose irradiated tumor tissue after cytoreductive radiotherapy. In the present study, the active specific immunotherapy using the tumor cells and infiltrating lymphocytes which were cryopreserved at -196 0 C in liquid nitrogen was investigated in female C3H/He mice inoculated MM46 tumor. Irradiation with the dose of 3,000 rads was performed on the sixth day. The tumor cells and lymphocytes which were separated from 2,000 rads-irradiated tumor tissue were frozen by the program freezer to be preserved at -196 0 C for two months and were thawed to inject into the tumor-bearing mice on the thirteenth day. Anti-tumor effect was evaluated by the regression of the tumor and survival curves. The remarkable regression of the tumor (p < 0.01) and significant elongation of the survival period (p < 0.1) were observed in the group which received the active specific immunotherapy using the cryopreserved tumor cells and lymphocytes as well as the group using the fresh tumor cells and lymphocytes prepared from a low-dose irradiated tumor tissue. (author)

  1. GRANULOCYTE INFILTRATION AND EXPRESSION OF THE PRO-ANGIOGENIC BV8 PROTEIN IN EXPERIMENTAL EL4 AND LEWIS LUNG CARCINOMA TUMORS.

    Science.gov (United States)

    Jiang, Kan; Kwak, Hyeongil; Tosato, Giovanna

    2013-01-18

    Although Vascular Endothelial Growth Factor (VEGF)-targeted therapies have shown efficacy in the treatment of certain advanced cancers, benefits to patients have been modest, which is attributed to tumor resistance to VEGF neutralization. Recent efforts to identify new targets to inhibit tumor angiogenesis have identified Bv8 (prokineticin 2), a myeloid cell-derived protein that promotes endothelial cell growth and tumor angiogenesis, but many mechanistic aspects of the pro-tumorigenic function of Bv8 are unclear. Here we demonstrate that CD11b+, Ly6C+, Ly6G+ granulocytes are the predominant cell source of Bv8 expression in bone marrow, spleen and in tumor tissues. Using granulocyte-deficient Growth factor independence-1 (Gfi1)-null mutant mice and normal littermates, we found that EL4 lymphoma tumors grow significantly larger in the granulocyte and Bv8-deficient mutant mice in comparison to the normal mice that display abundant tumor-associated granulocytes and Bv8 expression. Conversely, Lewis lung carcinoma (LLC-1) tumors grew to a significantly greater size in the normal mice in comparison to the Gfi1-null mice, but normal granulocyte tumor infiltration was modest. Quantitative analysis of tissue vascularization showed that EL4 and LLC-1 tumors from normal and Gfi1-mutant mice are similarly vascularized. These results confirm the critical contribution of the tumor microenvironment in determining the rate of tumor progression independently of tumor angiogenesis, and reveal some of the complexities of granulocyte and Bv8 functions in modulating tumor growth.

  2. Quark deconfinement in nuclei: A review of experimental tests based on nuclear magnetic moment measurements

    International Nuclear Information System (INIS)

    Stone, N.J.; Rikovska, J.

    1988-01-01

    The introduction very briefly outlines the basic idea and experimental evidence to suggest that quarks may behave differently in nuclei and in individual nucleons, with possible consequences for the calculation of nuclear magnetic dipole moments. After description of a calculation of moments made using the extreme model of total quark deconfinement (the MIT bag model) attention is focussed on experimental tests and the state of current evidence for more partial quark deconfinement. The arguments of Yamazaki which give an experimental basis for distinguishing quark deconfinement effects from, specifically, effects caused by pion exchange currents, are given in more detail. The reasons underlying choice of nuclei in which meaningful tests may be possible are given. Early claims by Karl et al. to have demonstrated the existence of quark deconfinement in mass 3 nuclei are discussed. The current status of evidence for deconfinement based on orbital g-factor measurements in heavier nuclei is also summarised. Finally some examples are given of possible experiments using recently developed on-line facilities which may provide further tests of these ideas. (orig.)

  3. Uncertainty in techno-economic estimates of cellulosic ethanol production due to experimental measurement uncertainty

    Directory of Open Access Journals (Sweden)

    Vicari Kristin J

    2012-04-01

    Full Text Available Abstract Background Cost-effective production of lignocellulosic biofuels remains a major financial and technical challenge at the industrial scale. A critical tool in biofuels process development is the techno-economic (TE model, which calculates biofuel production costs using a process model and an economic model. The process model solves mass and energy balances for each unit, and the economic model estimates capital and operating costs from the process model based on economic assumptions. The process model inputs include experimental data on the feedstock composition and intermediate product yields for each unit. These experimental yield data are calculated from primary measurements. Uncertainty in these primary measurements is propagated to the calculated yields, to the process model, and ultimately to the economic model. Thus, outputs of the TE model have a minimum uncertainty associated with the uncertainty in the primary measurements. Results We calculate the uncertainty in the Minimum Ethanol Selling Price (MESP estimate for lignocellulosic ethanol production via a biochemical conversion process: dilute sulfuric acid pretreatment of corn stover followed by enzymatic hydrolysis and co-fermentation of the resulting sugars to ethanol. We perform a sensitivity analysis on the TE model and identify the feedstock composition and conversion yields from three unit operations (xylose from pretreatment, glucose from enzymatic hydrolysis, and ethanol from fermentation as the most important variables. The uncertainty in the pretreatment xylose yield arises from multiple measurements, whereas the glucose and ethanol yields from enzymatic hydrolysis and fermentation, respectively, are dominated by a single measurement: the fraction of insoluble solids (fIS in the biomass slurries. Conclusions We calculate a $0.15/gal uncertainty in MESP from the TE model due to uncertainties in primary measurements. This result sets a lower bound on the error bars of

  4. Radiation effects on tumor-specific DTH response, 2

    International Nuclear Information System (INIS)

    Nobusawa, Hiroshi; Hachisu, Reiko.

    1991-01-01

    Tumor-specific immunity was induced in C3H mice by immunizing with syngeneic MH134 hepatoma cells. Radiation sensitivity of anti-tumor activity of immunized spleen cells were examined and compared with the radiation sensitivity of the delayed-type hypersensitivity (DTH)-response. The spleen cells were irradiated in vitro, then mixed with the tumor cells. DTH-response intensity was determined from the footpad increment twenty-four hours after inoculation of tumor cells with immunized spleen cells. Anti-tumor activity of the spleen cells, based on growth inhibition of tumor cells, was measured by a cytostatic test in vivo with diffusion chambers. Tumor-specific DTH response was suppressed dose-dependently in the range of 12-24 Gy irradiation. No suppression was observed below 12 Gy. Without irradiation, growth of tumor cells was inhibited by immunized spleen cells more effectively than by normal spleen cells. Anti-tumor activity of immunized and normal spleen cells was diminished by irradiation doses of 20 Gy and 10 Gy, respectively. Comparing our report with others that analyzed the type of anti-tumor effector cells induced in this experimental system, we concluded that tumor-specific anti-tumor activity (tumor growth inhibition in vivo) that was radiosensitive at 10-20 Gy depended on a DTH-response. (author)

  5. Experimental measurements of the eddy current signal due to a flawed, conducting half space

    International Nuclear Information System (INIS)

    Long, S.A.; Toomsawasdi, S.; Zaman, A.J.M.

    1984-01-01

    This chapter reports on an experimental investigation in which the change in impedance of a practical multi-turn eddy current coil near a conducting half space is measured as a function of the conductivity and the lift-off distance. The results are compared in a qualitative fashion with the analytical results for a single-turn coil. Measurements are also made of the change in impedance due to a small void in the conducting half space as a function of both its depth and radial position. The results indicate that, at least in a qualitative fashion, the precisely derived analytical solutions adequately predict the general behavior of the change in complex impedance of an eddy current coil above a conducting ground plane as a function of lift-off distance. It is determined that the effect of a sub-surface void on the change in inductance of the test coil correlates well with theoretical calculations

  6. Modeling and Experimental Tests of a Mechatronic Device to Measure Road Profiles Considering Impact Dynamics

    DEFF Research Database (Denmark)

    Souza, A.; Santos, Ilmar

    2002-01-01

    of a vehicle and to test its components in laboratory. In this framework a mechanism to measure road profiles is designed and presented. Such a mechanism is composed of two rolling wheels and two long beams attached to the vehicles by means of four Kardan joints. The wheels are kept in contact to the ground...... to highlight that the aim of this device is to independently measure two road profiles, without the influence of the vehicle dynamics where the mechanism is attached. Before the mechatronic mechanism is attached to a real vehicle, its dynamic behavior must be known. A theoretical analysis of the mechanism...... predicts well the mechanism movements. However it was also experimentally observed that the contact between the wheels and the road profile is not permanent. To analyze the non-contact between the wheels and the road, the Newton-Euler´s Method is used to calculate forces and moments of reactions between...

  7. Experimental study of sector and linear array ultrasound accuracy and the influence of navigated 3D-reconstruction as compared to MRI in a brain tumor model.

    Science.gov (United States)

    Siekmann, Max; Lothes, Thomas; König, Ralph; Wirtz, Christian Rainer; Coburger, Jan

    2018-03-01

    Currently, intraoperative ultrasound in brain tumor surgery is a rapidly propagating option in imaging technology. We examined the accuracy and resolution limits of different ultrasound probes and the influence of 3D-reconstruction in a phantom and compared these results to MRI in an intraoperative setting (iMRI). An agarose gel phantom with predefined gel targets was examined with iMRI, a sector (SUS) and a linear (LUS) array probe with two-dimensional images. Additionally, 3D-reconstructed sweeps in perpendicular directions were made of every target with both probes, resulting in 392 measurements. Statistical calculations were performed, and comparative boxplots were generated. Every measurement of iMRI and LUS was more precise than SUS, while there was no apparent difference in height of iMRI and 3D-reconstructed LUS. Measurements with 3D-reconstructed LUS were always more accurate than in 2D-LUS, while 3D-reconstruction of SUS showed nearly no differences to 2D-SUS in some measurements. We found correlations of 3D-reconstructed SUS and LUS length and width measurements with 2D results in the same image orientation. LUS provides an accuracy and resolution comparable to iMRI, while SUS is less exact than LUS and iMRI. 3D-reconstruction showed the potential to distinctly improve accuracy and resolution of ultrasound images, although there is a strong correlation with the sweep direction during data acquisition.

  8. Noninvasive measurement of nutrient portal blood shunting: an experimental study with [14C]ursodeoxycholic acid

    International Nuclear Information System (INIS)

    Nordlinger, B.; Parquet, M.; Infante, R.; Moreels, R.; Blondiau, P.; Boschat, M.; Groussard, M.; Huguet, C.

    1982-01-01

    All of the methods proposed for measuring portal blood flow are either invasive, estimate total rather than nutrient flow, and none has proved reliable in cirrhotic patients. A method has been derived from pharmacokinetic principles used for the calculation of bioavailability of drugs according to the route of administration (i.v. or p.o.) and tested experimentally in 20 pigs. A tracer dose of [ 14 C]ursodeoxycholic acid, a biliary acid with a high-liver first-pass effect, is administered in the duodenum, and serial peripheral blood samples are taken. Later, the same dose of the same drug is administered i.v. The shunt fraction of portal blood F is obtained by the ratio of the areas under the plasma level vs. time curves (AUC) after p.o. and i.v. administrations: (see formula in text). The pigs were divided into three experimental groups. (i) Group I: undisturbed portal flow; (ii) Group II: total diversion of portal blood with an end-to-side portacaval shunt, and (iii) Group III: partial diversion of portal blood through a side-to-side portacaval shunt. Portal flow was measured during surgery with an electromagnetic flowmeter above and below the shunt and the degree of shunting calculated. Results show that the shunt fraction measured with ursodeoxycholic acid is well-correlated with hemodynamic data. No overlap between Groups I and III is observed. It is concluded that the shunt fraction of nutrient portal blood can be measured with this noninvasive method. Minute amounts of ursodeoxycholic acid were used in order to be completely metabolized by the liver, even in spite of hepatocellular dysfunction. Therefore, this method should be valid in cirrhotic patients and be useful to decide the type of portasystemic shunt to propose for the decompression of gastroesophageal varices

  9. Experimental density and viscosity measurements of di(2ethylhexyl)sebacate at high pressure

    International Nuclear Information System (INIS)

    Paredes, Xavier; Fandino, Olivia; Pensado, Alfonso S.; Comunas, Maria J.P.; Fernandez, Josefa

    2012-01-01

    Highlights: → We measure viscosities for di(2-ethylhexyl)sebacate from (298.15 to 398.15) K and up to 60 MPa. → We measure densities for DEHS from (298.15 to 373.15) K and from (0.1 to 60) MPa. → The reported and lit. data were used in a viscosity correlation from (273 to 491) K and up to 1.1 GPa. → This correlation could be used in industrial equipment that operate at high pressures. - Abstract: Experimental densities and dynamic viscosities of di(2-ethylhexyl)sebacate (DEHS) are the object of study in this work. DEHS could be a useful industrial reference fluid for moderately high viscosity at high pressures as it is often used as a pressure transmitting fluid. At atmospheric pressure the density and viscosity measurements have been performed in a rotational SVM 3000 Stabinger viscometer from (273.15 to 373.15) K, whereas from (0.1 to 60) MPa and from (298.15 to 398.15) K an automated Anton Paar DMA HPM vibrating-tube densimeter, and a high-pressure rolling-ball viscometer were used. Several Vogel-Fulcher-Tammann type equations were used to fit the experimental values of viscosity to the pressure and temperature. The measured viscosity data have been used together with previous data found in the literature to establish a correlation of the viscosity surface η(T, p) of DEHS, covering a temperature range from (273 to 491) K and pressure up to 1.1 GPa. This correlation could be used in industrial equipment like viscometers and other devices that operate at high pressures. Our viscosity data have also been fitted as a function of temperature and volume to the thermodynamic scaling model of Roland et al. [C.M. Roland, S. Bair, R. Casalini, J. Chem. Phys. 125 (2006) 124508].

  10. A novel experimental mechanics method for measuring the light pressure acting on a solar sail membrane

    Science.gov (United States)

    Shi, Aiming; Jiang, Li; Dowell, Earl H.; Qin, Zhixuan

    2017-02-01

    Solar sail is a high potential `sailing craft' for interstellar exploration. The area of the first flight solar sail demonstrator named "IKAROS" is 200 square meters. Future interplanetary missions will require solar sails at least on the order of 10000 square meters (or larger). Due to the limitation of ground facilities, the size of experimental sample should not be large. Furthermore the ground experiments have to be conducted in gravitational field, so the gravity effect must be considered in a ground test. To obtain insight into the solar sail membrane dynamics, a key membrane flutter (or limit cycle oscillations) experiment with light forces acting on it must be done. But one big challenge is calibrating such a tiny light force by as a function of the input power. In this paper, a gravity-based measuring method for light pressure acting on membrane is presented. To explain the experimental principle, an ideal example of a laser beam with expanders and a metal film is studied. Based on calculations, this experimental mechanics method for calibrating light pressure with an accuracy of 0.01 micro-Newton may be realized by making the light force balance the gravity force on the metal films. This gravity-based measuring method could not only be applied to study the dynamics characteristics of solar sail membrane structure with different light forces, but could also be used to determine more accurate light forces/loads acting on solar sail films and hence to enhance the determination of the mechanical properties of the solar sail membrane structure.

  11. Experimental determination of an ionisation detector for measuring the nuclear lifetime

    International Nuclear Information System (INIS)

    Tisserant, S.

    1982-06-01

    The proton or neutron decay signature needs a good measurement of the varied produced particle energy, together with a good identification of them. The lack of experimental data on electron and charged pion of low energy led to experiment two series of tests. This thesis study precise, from these tests, the performances of the detector that will be installed at Modane. Prototype performances are first studied, concerning the particle energy measurement (electron and charged pions) and their identification. To extrapolate these results to the final detector, simulation programs will be used. The application of such a program that Electron-Gamma-Shower to energies below 500 MeV/c 2 for electromagnetic showers will be verified. For the pions, a simulation program of pion-nucleus interactions at low energy will be checked out from the experimental test data. Scattering effects, charge exchange and absorption are particularly concerned. These simulations reproduce the prototype results; they will be applied to the expected decay modes of proton and neutron. It will be shown that a fine grain detector. Shows a comparable sensitivty for every mode without final neutrino. Triggering probability and decay sign probability will be studied particularly [fr

  12. Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

    International Nuclear Information System (INIS)

    Asai, Keisuke; Naoi, Norihiro; Iguchi, Tetsuo; Watanabe, Kenichi; Kawarabayashi, Jun; Nishitani, Takeo

    2006-01-01

    The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (φ20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW). (author)

  13. Experimental technologies comparison for strain measurement of a composite main landing gear bay specimen

    Science.gov (United States)

    Viscardi, Massimo; Arena, Maurizio; Ciminello, Monica; Guida, Michele; Meola, Carosena; Cerreta, Pietro

    2018-03-01

    The development of advanced monitoring system for strain measurements on aeronautical components remain an important target both when related to the optimization of the lead-time and cost for part validation, allowing earlier entry into service, and when related to the implementation of advanced health monitoring systems dedicated to the in-service parameters verification and early stage detection of structural problems. The paper deals with the experimental testing of a composite samples set of the main landing gear bay for a CS-25 category aircraft, realized through an innovative design and production process. The test have represented a good opportunity for direct comparison of different strain measurement techniques: Strain Gauges (SG) and Fibers Bragg Grating (FBG) have been used as well as non-contact techniques, specifically the Digital Image Correlation (DIC) and Infrared (IR) thermography applied where possible in order to highlight possible hot-spot during the tests. The crucial points identification on the specimens has been supported by means of advanced finite element simulations, aimed to assessment of the structural strength and deformation as well as to ensure the best performance and the global safety of the whole experimental campaign.

  14. Measuring treatment response to systemic therapy and predicting outcome in biliary tract cancer: comparing tumor size, volume, density, and metabolism.

    Science.gov (United States)

    Sahani, Dushyant V; Hayano, Koichi; Galluzzo, Anna; Zhu, Andrew X

    2015-04-01

    The purpose of this study was to evaluate the response of biliary tract cancer treated with multidrug chemotherapy using FDG PET in comparison with morphologic and density changes. In this phase II clinical trial, 28 patients with unresectable or metastatic biliary tract cancers treated with gemcitabine and oxaliplatin combined with bevacizumab (GEMOX-B) underwent FDG PET and contrast-enhanced CT at baseline and after the second cycle of the therapy (8 weeks). A single reviewer recorded tumor maximum standardized uptake value (SUVmax) along with size, volume (3D-sphere), and density. The percentage changes of the parameters were compared with progression-free survival at 7 months. Overall survival was compared with the percentage change of SUVmax. After 8 weeks, measurable reductions (±SD) in size (7.05±4.19 to 5.52±3.28 cm, -21.70%), volume (411.38±540.08 to 212.41±293.45 cm3, -48.36%), and density (60.76±20.65 to 50.68±16.89 HU, -15.59%) were noted along with a substantial drop in SUVmax (5.95±1.95 to 3.36±1.28, -43.52%). The SUVmax change showed positive correlations with tumor size change (R2=0.39, p=0.0004) and volumetric change (R2=0.34, p=0.001). Patients who showed a larger drop in SUVmax at 8 weeks correlated with favorable progression-free survival (p=0.02). ROC analysis showed that a 45% reduction in SUVmax was the best cutoff value to detect favorable progression-free survival patients. When we used this cutoff value, Kaplan-Meier analysis showed that patients with tumors showing greater reduction in SUVmax had favorable progression-free survival and overall survival (p=0.0009, p=0.03). In biliary tract cancers treated with GEMOX-B, the reduction of SUVmax after therapy is a better predictor for survival than morphologic and density changes.

  15. Experimental Measurement and Numerical Modeling of the Effective Thermal Conductivity of TRISO Fuel Compacts

    International Nuclear Information System (INIS)

    Folsom, Charles

    2015-01-01

    Accurate modeling capability of thermal conductivity of tristructural-isotropic (TRISO) fuel compacts is important to fuel performance modeling and safety of Generation IV reactors. To date, the effective thermal conductivity (ETC) of tristructural-isotropic (TRISO) fuel compacts has not been measured directly. The composite fuel is a complicated structure comprised of layered particles in a graphite matrix. In this work, finite element modeling is used to validate an analytic ETC model for application to the composite fuel material for particle-volume fractions up to 40%. The effect of each individual layer of a TRISO particle is analyzed showing that the overall ETC of the compact is most sensitive to the outer layer constituent. In conjunction with the modeling results, the thermal conductivity of matrix-graphite compacts and the ETC of surrogate TRISO fuel compacts have been successfully measured using a previously developed measurement system. The ETC of the surrogate fuel compacts varies between 50-30 W m -1 K -1 over a temperature range of 50-600°C. As a result of the numerical modeling and experimental measurements of the fuel compacts, a new model and approach for analyzing the effect of compact constituent materials on ETC is proposed that can estimate the fuel compact ETC with approximately 15-20% more accuracy than the old method. Using the ETC model with measured thermal conductivity of the graphite matrix-only material indicate that, in the composite form, the matrix material has a much greater thermal conductivity, which is attributed to the high anisotropy of graphite thermal conductivity. Therefore, simpler measurements of individual TRISO compact constituents combined with an analytic ETC model, will not provide accurate predictions of overall ETC of the compacts emphasizing the need for measurements of composite, surrogate compacts.

  16. Measurement of Lung Cancer Tumor Markers in a Glass Wool Company Workers Exposed to Respirable Synthetic Vitreous Fiber and Dust

    Directory of Open Access Journals (Sweden)

    Shabnam Abtahi

    2018-01-01

    Full Text Available Background: Occupational exposures to respirable synthetic vitreous fiber (SVF and dust are associated with many lung diseases including lung cancer. Low-dose computed tomography is used for screening patients who are highly suspicious of having lung carcinoma. However, it seems not to be cost-effective. Serum biomarkers could be a useful tool for the surveillance of occupational exposure, by providing the possibility of diagnosing lung cancer in its early stages. Objective: To determine if serum carcinoembryonic antigen (CEA and cytokeratin fragment (CYFRA 21-1 levels in workers exposed more than normal population to respirable SVF and dust may be used as indicators of progression towards lung cancer. Methods: An analytic cross-sectional study, including 145 personnel of a glass wool company, along with 25 age-matched healthy individuals, was conducted to investigate the relationship between occupational exposure to respirable SVFs and dust and serum levels of two lung/pleura serum tumor markers, CEA and CYFRA 21-1, measured by ELISA. Results: Individuals exposed to higher than the recommended levels of respirable SVF had higher serum concentrations of CEA and CYFRA 21-1, compared to controls (p=0.008 and 0.040, respectively, as well as in comparison to those exposed to lower than recommended OSHA levels (p=0.046 and 0.033, respectively. Workers with >9 years work experience, had significantly (p=0.045 higher levels of serum CYFRA 21-1 than those with ≤9 years of experience. Conclusion: It seems that working for >9 years in sites with detectable levels of respirable SVF and dust would increase the levels of known lung cancer serum tumor markers. Transferring these workers to sites with respirable SVF concentrations lower than the limit of detection in the air is recommended.

  17. Experimental measurement of compressibility coefficients of synthetic sandstone in hydrostatic conditions

    International Nuclear Information System (INIS)

    Asaei, H; Moosavi, M

    2013-01-01

    For the characterization of the mechanical behavior of porous media in elastic conditions, the theory of poroelasticity is used. The number of poroelastic coefficients is greater in elastic conditions because of the complexity of porous media. The laboratory measurement of poroelastic coefficients needs a system that can control and measure the variables of poroelasticity. In this paper, experimental measurements of these coefficients are presented. Laboratory tests are performed using a system designed by the authors. Laboratory hydrostatic tests are performed on cylindrical samples in drained, pore pressure loading, undrained and dry conditions. Compressibilities (bulk and pore compressibility), effective stress and Skempton coefficients are measured by these tests. Samples are made of a composition (sand and cement) and are made by a compaction process synthetically. Calibration tests are performed for the setup to identify possible errors in the system and to correct the results of the main tests. This is done by performing similar compressibility tests at each stress level on a cylindrical steel sample (5.47 mm in diameter) with a longitudinal hole along it (hollow cylinder). A steel sample is used to assume an incompressible sample. The results of the tests are compared with the theory of poroelasticity and the obtained graphs and their errors are analyzed. This study shows that the results of the drained and pore pressure loading tests are compatible with poroelastic formulation, while the undrained results have errors because of extra fluid volume in the pore pressure system and calibration difficulties. (paper)

  18. Experimental reslts from the HERO project: In situ measurements of ionospheric modifications using sounding rockets

    International Nuclear Information System (INIS)

    Rose, G.; Grandal, B.; Neske, E.; Ott, W.; Spenner, K.; Maseide, K.; Troim, J.

    1985-01-01

    The Heating Rocket project HERO comprised the first in situ experiments to measure artifical ionospheric modifications at F layer heights set up by radio waves transmitted from the Heating facility at Ramfjord near Tromso in Northern Norway. Four instrumented payloads were launched on sounding rockets from Andoya Rocket Range during the autumn of 1982 into a sunlit ionosphere with the sun close to the horizon. The payloads recorded modifications, in particular, the presence of electron plasma waves near the reflection level of the heating wave. The amplitude and phase of the three components of the electric and magnetic fields of the heating wave were measured simultaneously as a function of altitude. Coherent spectra of the three electric field components of the locally generated electron plasma waves were obtained in a 50-kHz-wide band. At the same time quasi-continuous measurements were made on several fixed frequencies from 4 kHz to 16 kHz below the heating frequency and in the VLF-range using linear dipole antennas. Moreover, measurements were made of electron temperature, suprathermal electrons and local electron density along the rocket trajectory. The experimental results will be presented and discussed

  19. Design of an experimental apparatus for measurement of the surface tension of metastable fluids

    Science.gov (United States)

    Vinš, V.; Hrubý, J.; Hykl, J.; Blaha, J.; Šmíd, B.

    2013-04-01

    A unique experimental apparatus for measurement of the surface tension of aqueous mixtures has been designed, manufactured, and tested in our laboratory. The novelty of the setup is that it allows measurement of surface tension by two different methods: a modified capillary elevation method in a long vertical capillary tube and a method inspired by the approach of Hacker (National Advisory Committee for Aeronautics, Technical Note 2510, 1-20, 1951), i.e. in a short horizontal capillary tube. Functionality of all main components of the apparatus, e.g., glass chamber with the capillary tube, temperature control unit consisting of two thermostatic baths with special valves for rapid temperature jumps, helium distribution setup allowing pressure variation above the liquid meniscus inside the capillary tube, has been successfully tested. Preliminary results for the surface tension of the stable and metastable supercooled water measured by the capillary elevation method at atmospheric pressure are provided. The surface tension of water measured at temperatures between +26 °C and -11 °C is in good agreement with the extrapolated IAPWS correlation (IAPWS Release on Surface Tension of Ordinary Water Substance, September 1994); however it disagrees with data by Hacker.

  20. Experimental measurement of enthalpy increments of Th0.25Ce0.75O2

    International Nuclear Information System (INIS)

    Babu, R.; Balakrishnan, S.; Ananthasivan, K.; Nagarajan, K.

    2013-01-01

    Thorium has been suggested as an alternative fertile material for a nuclear fuel cycle, and an inert matrix for burning plutonium and for waste disposal. The third stage of India's nuclear power programme envisages utilization of thorium and plutonium as a fuel in Advanced Heavy Water Reactor (AHWR) and Accelerator Driven Sub-critical Systems (ADSS). Solid solutions of ThO 2 -PuO 2 are of importance because of coexistence of Th with Pu during the breeding cycle. CeO 2 is used as a PuO 2 analog due to similar ionic radii of cations and similar physico-chemical properties of the oxides. ThO 2 forms a homogeneous solid solution with the cubic fluorite structure when doped with Ce in the entire compositional range. In the development of mixed oxide nuclear fuels, knowledge of thermodynamic properties of thorium oxide and its mixtures has become extremely importance for understanding the fuel behavior during irradiation and for predicting the performance of the fuel under accidental conditions. Thermodynamic functions such as the enthalpy increment and heat capacity of the theria-ceria solid solution have not been measured experimentally. Hence, the enthalpy increments of thoria-ceria solid solutions, Th 0.25 Ce 0.75 O 2 by inverse drop calorimetry in the temperature range 523-1723 K have been measured. The measured enthalpy increments were fitted in to polynomial functions by using the least squares method and the other thermodynamic functions such as heat capacity, entropy and Gibbs energy functions were computed in the temperature range 298-1800 K. The reported thermodynamic functions for Th 0.25 Ce 0.75 O 2 forms the first experimental data and the heat capacity of (Th,Ce)O 2 solid solutions was shown to obey the Neumann-Kopp's rule. (author)

  1. Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

    Directory of Open Access Journals (Sweden)

    Afshin Akbarzadeh

    2009-06-01

    Full Text Available Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter correction techniques. Empirical methods based on blocking the primary photons in a small region are not able to extract scatter in all elements of the detector array while the scatter profile is required for a scatter correction procedure. In this study, we measured scatter profiles in 64 slice CT scanners using a new experimental measurement. Material and Methods: To measure the scatter profile, a lead block array was inserted under the collimator and the phantom was exposed at the isocenter. The raw data file, which contained detector array readouts, was transferred to a PC and was read using a dedicated GUI running under MatLab 7.5. The scatter profile was extracted by interpolating the shadowed area. Results: The scatter and SPR profiles were measured. Increasing the tube voltage from 80 to 140 kVp resulted in an 80% fall off in SPR for a water phantom (d=210 mm and 86% for a polypropylene phantom (d = 350 mm. Increasing the air gap to 20.9 cm caused a 30% decrease in SPR. Conclusion: In this study, we presented a novel approach for measurement of scattered radiation distribution and SPR in a CT scanner with 64-slice capability using a lead block array. The method can also be used on other multi-slice CT scanners. The proposed technique can accurately estimate scatter profiles. It is relatively straightforward, easy to use, and can be used for any related measurement.

  2. Bone tumors

    International Nuclear Information System (INIS)

    Unni, K.K.

    1988-01-01

    This book contains the proceedings on bone tumors. Topics covered include: Bone tumor imaging: Contribution of CT and MRI, staging of bone tumors, perind cell tumors of bone, and metastatic bone disease

  3. Quantitative image cytometry measurements of lipids, DNA, CD45 and cytokeratin for circulating tumor cell identification in a model system

    Science.gov (United States)

    Futia, Gregory L.; Qamar, Lubna; Behbakht, Kian; Gibson, Emily A.

    2016-04-01

    Circulating tumor cell (CTC) identification has applications in both early detection and monitoring of solid cancers. The rarity of CTCs, expected at ~1-50 CTCs per million nucleated blood cells (WBCs), requires identifying methods based on biomarkers with high sensitivity and specificity for accurate identification. Discovery of biomarkers with ever higher sensitivity and specificity to CTCs is always desirable to potentially find more CTCs in cancer patients thus increasing their clinical utility. Here, we investigate quantitative image cytometry measurements of lipids with the biomarker panel of DNA, Cytokeratin (CK), and CD45 commonly used to identify CTCs. We engineered a device for labeling suspended cell samples with fluorescent antibodies and dyes. We used it to prepare samples for 4 channel confocal laser scanning microscopy. The total data acquired at high resolution from one sample is ~ 1.3 GB. We developed software to perform the automated segmentation of these images into regions of interest (ROIs) containing individual cells. We quantified image features of total signal, spatial second moment, spatial frequency second moment, and their product for each ROI. We performed measurements on pure WBCs, cancer cell line MCF7 and mixed samples. Multivariable regressions and feature selection were used to determine combination features that are more sensitive and specific than any individual feature separately. We also demonstrate that computation of spatial characteristics provides higher sensitivity and specificity than intensity alone. Statistical models allowed quantification of the required sensitivity and specificity for detecting small levels of CTCs in a human blood sample.

  4. Tumor control probability after a radiation of animal tumors

    International Nuclear Information System (INIS)

    Urano, Muneyasu; Ando, Koichi; Koike, Sachiko; Nesumi, Naofumi

    1975-01-01

    Tumor control and regrowth probability of animal tumors irradiated with a single x-ray dose were determined, using a spontaneous C3H mouse mammary carcinoma. Cellular radiation sensitivity of tumor cells and tumor control probability of the tumor were examined by the TD 50 and TCD 50 assays respectively. Tumor growth kinetics were measured by counting the percentage of labelled mitosis and by measuring the growth curve. A mathematical analysis of tumor control probability was made from these results. A formula proposed, accounted for cell population kinetics or division probability model, cell sensitivity to radiation and number of tumor cells. (auth.)

  5. Dynamic microbubble contrast-enhanced US to measure tumor response to targeted therapy: a proposed clinical protocol with results from renal cell carcinoma patients receiving antiangiogenic therapy.

    Science.gov (United States)

    Williams, Ross; Hudson, John M; Lloyd, Brendan A; Sureshkumar, Ahthavan R; Lueck, Gordon; Milot, Laurent; Atri, Mostafa; Bjarnason, Georg A; Burns, Peter N

    2011-08-01

    To develop and implement an evidence-based protocol for characterizing vascular response of renal cell carcinoma (RCC) to targeted therapy by using dynamic contrast material-enhanced (DCE) ultrasonography (US). The study was approved by the institutional research ethics board; written informed consent was obtained from all patients. Seventeen patients (four women; median age, 58 years; range, 42-72 years; 13 men, median age, 62 years; range, 45-81 years) with metastatic RCC were examined by using DCE US before and after 2 weeks of treatment with sunitinib (May 2007 to October 2009). Two contrast agent techniques--bolus injection and disruption-replenishment infusion of microbubbles--were compared. Changes in tumor blood velocity and fractional blood volume were measured with both methods, together with reproducibility and effect of compensation for respiratory motion. Tumor changes were assessed with computed tomography, by using the best response with the Response Evaluation Criteria in Solid Tumors (RECIST) and progression-free survival (PFS). Follow-up RECIST measurements were performed at 6-week intervals until progressive disease was detected. In response to treatment, median tumor fractional blood volume measured with the disruption-replenishment infusion method decreased by 73.2% (interquartile range, 46%-87%) (P protocol is a flexible method suitable for many tumor types, but further studies are needed to assess whether this protocol may be predictive of patient outcome. © RSNA, 2011.

  6. A heat transport benchmark problem for predicting the impact of measurements on experimental facility design

    International Nuclear Information System (INIS)

    Cacuci, Dan Gabriel

    2016-01-01

    Highlights: • Predictive Modeling of Coupled Multi-Physics Systems (PM_CMPS) methodology is used. • Impact of measurements for reducing predicted uncertainties is highlighted. • Presented thermal-hydraulics benchmark illustrates generally applicable concepts. - Abstract: This work presents the application of the “Predictive Modeling of Coupled Multi-Physics Systems” (PM_CMPS) methodology conceived by Cacuci (2014) to a “test-section benchmark” problem in order to quantify the impact of measurements for reducing the uncertainties in the conceptual design of a proposed experimental facility aimed at investigating the thermal-hydraulics characteristics expected in the conceptual design of the G4M reactor (GEN4ENERGY, 2012). This “test-section benchmark” simulates the conditions experienced by the hottest rod within the conceptual design of the facility's test section, modeling the steady-state conduction in a rod heated internally by a cosinus-like heat source, as typically encountered in nuclear reactors, and cooled by forced convection to a surrounding coolant flowing along the rod. The PM_CMPS methodology constructs a prior distribution using all of the available computational and experimental information, by relying on the maximum entropy principle to maximize the impact of all available information and minimize the impact of ignorance. The PM_CMPS methodology then constructs the posterior distribution using Bayes’ theorem, and subsequently evaluates it via saddle-point methods to obtain explicit formulas for the predicted optimal temperature distributions and predicted optimal values for the thermal-hydraulics model parameters that characterized the test-section benchmark. In addition, the PM_CMPS methodology also yields reduced uncertainties for both the model parameters and responses. As a general rule, it is important to measure a quantity consistently with, and more accurately than, the information extant prior to the measurement. For

  7. Specificity of antigens on UV radiation-induced antigenic tumor cell variants measured in vitro and in vivo

    International Nuclear Information System (INIS)

    Hostetler, L.W.; Romerdahl, C.A.; Kripke, M.L.

    1989-01-01

    The purpose of this study was to determine whether antigenic variants cross-react immunologically with the parental tumor and whether the UVR-associated antigen unique to UVR-induced tumors is also present on the variants. Antigenic (regressor) variants and nonimmunogenic (progressor) clones derived from UV-irradiated cultures of the C3H K1735 melanoma and SF19 spontaneous fibrosarcoma cell lines were used to address these questions. In an in vivo immunization and challenge assay, the antigenic variants did not induce cross-protection among themselves, but each induced immunity against the immunizing variant, the parent tumor cells, and nonimmunogenic clones derived from UV-irradiated parent cultures. Therefore, the variants can be used to induce in mice a protective immunity that prevents the growth of the parent tumor and nonimmunogenic clones, but not other antigenic variants. In contrast, immunization with cells of the parental tumor or the nonimmunogenic clones induced no protective immunity against challenge with any of the cell lines. Utilizing the K1735 melanoma-derived cell lines in vitro, T-helper (Th) cells isolated from tumor-immunized mice were tested for cross-reactivity by their ability to collaborate with trinitrophenyl-primed B-cells in the presence of trinitrophenyl-conjugated tumor cells. Also, the cross-reactivity of cytotoxic T-lymphocytes from tumor-immunized mice was assessed by a 4-h 51Cr-release assay. Antigenic variants induced cytotoxic T-lymphocytes and Th activity that was higher than that induced by the parent tumor and nonimmunogenic clones from the UVR-exposed parent tumor and cross-reacted with the parental tumor cells and nonimmunogenic clones, but not with other antigenic variants

  8. Exploring intra- and inter-reader variability in uni-dimensional, bi-dimensional, and volumetric measurements of solid tumors on CT scans reconstructed at different slice intervals

    International Nuclear Information System (INIS)

    Zhao, Binsheng; Tan, Yongqiang; Bell, Daniel J.; Marley, Sarah E.; Guo, Pingzhen; Mann, Helen; Scott, Marietta L.J.; Schwartz, Lawrence H.; Ghiorghiu, Dana C.

    2013-01-01

    Objective: Understanding magnitudes of variability when measuring tumor size may be valuable in improving detection of tumor change and thus evaluating tumor response to therapy in clinical trials and care. Our study explored intra- and inter-reader variability of tumor uni-dimensional (1D), bi-dimensional (2D), and volumetric (VOL) measurements using manual and computer-aided methods (CAM) on CT scans reconstructed at different slice intervals. Materials and methods: Raw CT data from 30 patients enrolled in oncology clinical trials was reconstructed at 5, 2.5, and 1.25 mm slice intervals. 118 lesions in the lungs, liver, and lymph nodes were analyzed. For each lesion, two independent radiologists manually and, separately, using computer software, measured the maximum diameter (1D), maximum perpendicular diameter, and volume (CAM only). One of them blindly repeated the measurements. Intra- and inter-reader variability for the manual method and CAM were analyzed using linear mixed-effects models and Bland–Altman method. Results: For the three slice intervals, the maximum coefficients of variation for manual intra-/inter-reader variability were 6.9%/9.0% (1D) and 12.3%/18.0% (2D), and for CAM were 5.4%/9.3% (1D), 11.3%/18.8% (2D) and 9.3%/18.0% (VOL). Maximal 95% reference ranges for the percentage difference in intra-reader measurements for manual 1D and 2D, and CAM VOL were (−15.5%, 25.8%), (−27.1%, 51.6%), and (−22.3%, 33.6%), respectively. Conclusions: Variability in measuring the diameter and volume of solid tumors, manually and by CAM, is affected by CT slice interval. The 2.5 mm slice interval provides the least measurement variability. Among the three techniques, 2D has the greatest measurement variability compared to 1D and 3D

  9. Measurement of the ratio of hydrogen to deuterium at the KSTAR 2009 experimental campaign

    International Nuclear Information System (INIS)

    Kwak, Jong-Gu; Wang, Son Jong; Kim, Sun Ho; Park, Jae Min; Na, Hoon Kyun

    2010-01-01

    The control of the ratio of hydrogen to the deuterium is one of the very important issues for ion cyclotron range of frequency (ICRF) minority heating as well as the plasma wall interaction in the tokamak. The ratio of hydrogen to deuterium during the tokamak shot was deduced from the emission spectroscopy measurements during the KSTAR 2009 experimental campaign. Graphite tiles were used for the plasma facing components (PFCs) at KSTAR and its surface area exposed to the plasma was about 11 m 2 . The data showed that it remained as high as around 50% during the campaign period because graphite tiles were exposed to the air for about two months and the hydrogen contents at the tiles are not fully pumped out due to the lack of baking on the PFC in the 2009 campaign. The validation of the spectroscopy method was checked by using the Zeeman effects and the ratio of hydrogen to the deuterium is compared with results from the residual gas analysis. During the tokamak shot, the ratio is low below 10% initially and saturated after around 1 s. When there is a hydrogen injection to the vessel via ion cyclotron wall conditioning and the boronization process where the carbone is used, the ratio of the hydrogen to the deuterium is increased by up to 100% and it recovers to around 50% after one day of operation. However it does not decrease below 50% at the end of the experimental campaign. It was found that the full baking on the PFC (with a high temperature and sufficient vacuum pumping) is required for the ratio control which guarantees the efficient ICRF heating at the KSTAR 2010 experimental campaign.

  10. DEAR Monte Carlo simulation versus experimental data in measurements with the DEAR NTP setup

    International Nuclear Information System (INIS)

    Bragadireanu, A.M.; Iliescu, M.; Petrascu, C.; Ponta, T.

    1999-01-01

    The DEAR NTP setup was installed in DAΦNE and is taking background data since February 1999. The goal of this work is to compare the measurements, in terms of charged particle hits (clusters), with the DEAR Monte Carlo simulation, taking into account the main effects due to which the particles are lost from circulating beams: Touschek effect and beam-gas interaction. To be mentioned that, during this period, no collisions between electrons and positrons have been achieved in the DEAR Interaction Point (IP) and consequently we don't have any experimental data concerning the hadronic background coming from φ-decays directly, or as secondary products of hadronic interactions. The NTP setup was shielded using lead and copper which gives a shielding factor of about 4. In parallel with the NTP setup, the signals from two scintillator slabs (150 x 80 x 2 mm) collected by 4 PMTs, positioned bellow the NTP setup and facing the IP, were digitized and counted using a National Instruments Timer/Counter Card. To compare experimental data with results of the Monte Carlo simulation we selected periods with only one circulating beam (electrons or positrons), in order to have a clean data set and we selected data files with CCD occupancy lower than 5%. As concerning the X-rays, the statistics was too poor to perform any quantitative comparison. The comparison between Monte Carlo, CCD data and kaon monitor data, for two beams are shown. It can be seen the agreement is fairly good and promising along the way of checking our routines which describes the experimental setup and the physical processes occurring in the accelerator environment. (authors)

  11. Comparative performance of three experimental hut designs for measuring malaria vector responses to insecticides in Tanzania.

    Science.gov (United States)

    Massue, Dennis J; Kisinza, William N; Malongo, Bernard B; Mgaya, Charles S; Bradley, John; Moore, Jason D; Tenu, Filemoni F; Moore, Sarah J

    2016-03-15

    Experimental huts are simplified, standardized representations of human habitations that provide model systems to evaluate insecticides used in indoor residual spray (IRS) and long-lasting insecticidal nets (LLINs) to kill disease vectors. Hut volume, construction materials and size of entry points impact mosquito entry and exposure to insecticides. The performance of three standard experimental hut designs was compared to evaluate insecticide used in LLINs. Field studies were conducted at the World Health Organization Pesticide Evaluation Scheme (WHOPES) testing site in Muheza, Tanzania. Three East African huts, three West African huts, and three Ifakara huts were compared using Olyset(®) and Permanet 2.0(®) versus untreated nets as a control. Outcomes measured were mortality, induced exophily (exit rate), blood feeding inhibition and deterrence (entry rate). Data were analysed using linear mixed effect regression and Bland-Altman comparison of paired differences. A total of 613 mosquitoes were collected in 36 nights, of which 13.5% were Anopheles gambiae sensu lato, 21% Anopheles funestus sensu stricto, 38% Mansonia species and 28% Culex species. Ifakara huts caught three times more mosquitoes than the East African and West African huts, while the West African huts caught significantly fewer mosquitoes than the other hut types. Mosquito densities were low, very little mosquito exit was measured in any of the huts with no measurable exophily caused by the use of either Olyset or Permanet. When the huts were directly compared, the West African huts measured greater exophily than other huts. As unholed nets were used in the experiments and few mosquitoes were captured, it was not possible to measure difference in feeding success either between treatments or hut types. In each of the hut types there was increased mortality when Permanet or Olyset were present inside the huts compared to the control, however this did not vary between the hut types. Both East African

  12. Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements

    Science.gov (United States)

    Zoros, E.; Moutsatsos, A.; Pappas, E. P.; Georgiou, E.; Kollias, G.; Karaiskos, P.; Pantelis, E.

    2017-09-01

    Detector-, field size- and machine-specific correction factors are required for precise dosimetry measurements in small and non-standard photon fields. In this work, Monte Carlo (MC) simulation techniques were used to calculate the k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} and k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors for a series of ionization chambers, a synthetic microDiamond and diode dosimeters, used for reference and/or output factor (OF) measurements in the Gamma Knife Perfexion photon fields. Calculations were performed for the solid water (SW) and ABS plastic phantoms, as well as for a water phantom of the same geometry. MC calculations for the k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors in SW were compared against corresponding experimental results for a subset of ionization chambers and diode detectors. Reference experimental OF data were obtained through the weighted average of corresponding measurements using TLDs, EBT-2 films and alanine pellets. k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} values close to unity (within 1%) were calculated for most of ionization chambers in water. Greater corrections of up to 6.0% were observed for chambers with relatively large air-cavity dimensions and steel central electrode. A phantom correction of 1.006 and 1.024 (breaking down to 1.014 from the ABS sphere and 1.010 from the accompanying ABS phantom adapter) were calculated for the SW and ABS phantoms, respectively, adding up to k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} corrections in water. Both measurements and MC calculations for the diode and microDiamond detectors resulted in lower than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors, due to their denser sensitive volume and encapsulation materials. In comparison, higher than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} results for the ionization chambers suggested field size depended dose underestimations (being significant for the 4 mm field), with magnitude depending on the combination of

  13. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  14. Experimental pain ratings and reactivity of cortisol and soluble tumor necrosis factor-α receptor II following a trial of hypnosis: Results of a randomized controlled pilot study

    Science.gov (United States)

    Goodin, Burel R.; Quinn, Noel B.; Kronfli, Tarek; King, Christopher D.; Page, Gayle G.; Haythornthwaite, Jennifer A.; Edwards, Robert R.; Stapleton, Laura M.; McGuire, Lynanne

    2011-01-01

    Objective Current evidence supports the efficacy of hypnosis for reducing the pain associated with experimental stimulation and various acute and chronic conditions; however, the mechanisms explaining how hypnosis exerts its effects remain less clear. The hypothalamic-pituitary-adrenal (HPA) axis and pro-inflammatory cytokines represent potential targets for investigation given their purported roles in the perpetuation of painful conditions; yet, no clinical trials have thus far examined the influence of hypnosis on these mechanisms. Design Healthy participants, highly susceptible to the effects of hypnosis, were randomized to either a hypnosis intervention or a no-intervention control. Using a cold pressor task, assessments of pain intensity and pain unpleasantness were collected prior to the intervention (Pre) and following the intervention (Post) along with pain-provoked changes in salivary cortisol and the soluble receptor of tumor necrosis factor-α (sTNFαRII). Results Compared to the no-intervention control, data analyses revealed that hypnosis significantly reduced pain intensity and pain unpleasantness. Hypnosis was not significantly associated with suppression of cortisol or sTNFαRII reactivity to acute pain from Pre to Post; however, the effect sizes for these associations were medium-sized. Conclusions Overall, the findings from this randomized controlled pilot study support the importance of a future large-scale study on the effects of hypnosis for modulating pain-related changes of the HPA axis and pro-inflammatory cytokines. PMID:22233394

  15. Experimental measurements and integrated modelling studies of actinide sorption onto cement

    International Nuclear Information System (INIS)

    Sugiyama, Daisuke; Fujita, Tomonari; Baston, G.M.N.

    2003-01-01

    An Integrated Cement Sorption Model (ICSM) for actinides onto Ordinary Portland Cement (OPC) is developed. The experimental measurements using the batch sorption technique for actinides onto cement and constituent minerals, which were considered in the modelling calculations, are also described. The actinide elements studied (thorium, uranium, neptunium, plutonium and americium) were strongly sorbed onto OPC. An initial comparison of the experimental data relating the sorption values of actinides onto cement-component phases with those onto OPC is carried out. The results suggest that the Calcium Silicate Hydrate (C-S-H) phases were found to be the most likely candidates to be the dominant-sorbing phases in order to describe the sorption of a actinides onto OPC. An approach to develop the integrated cement sorption model, based on a thermodynamic surface complexation model, is described with discussions on the possible mineralogy and phase distribution of OPC. Another approach than sorption, assuming that co-precipitation on the surface of the cement phase dominates 'sorption', is proposed and discussed. A scoring system is introduced to assess the applicability of the proposed ICSMs. It is suggested that the thermodynamic sorption model is recommended for the sorption of ionic species and the surface co-precipitation model is recommended for the sorption of neutral species though the sorption model is still recommended to be used to model OPC-based systems. (author)

  16. An Experimental Comparison of Similarity Assessment Measures for 3D Models on Constrained Surface Deformation

    Science.gov (United States)

    Quan, Lulin; Yang, Zhixin

    2010-05-01

    To address the issues in the area of design customization, this paper expressed the specification and application of the constrained surface deformation, and reported the experimental performance comparison of three prevail effective similarity assessment algorithms on constrained surface deformation domain. Constrained surface deformation becomes a promising method that supports for various downstream applications of customized design. Similarity assessment is regarded as the key technology for inspecting the success of new design via measuring the difference level between the deformed new design and the initial sample model, and indicating whether the difference level is within the limitation. According to our theoretical analysis and pre-experiments, three similarity assessment algorithms are suitable for this domain, including shape histogram based method, skeleton based method, and U system moment based method. We analyze their basic functions and implementation methodologies in detail, and do a series of experiments on various situations to test their accuracy and efficiency using precision-recall diagram. Shoe model is chosen as an industrial example for the experiments. It shows that shape histogram based method gained an optimal performance in comparison. Based on the result, we proposed a novel approach that integrating surface constrains and shape histogram description with adaptive weighting method, which emphasize the role of constrains during the assessment. The limited initial experimental result demonstrated that our algorithm outperforms other three algorithms. A clear direction for future development is also drawn at the end of the paper.

  17. Calculation of kinetic parameters of Caliban metallic core experimental reactor from stochastic neutron measurements

    Energy Technology Data Exchange (ETDEWEB)

    Casoli, P.; Authier, N.; Baud, J. [Commissariat a l' energie Atomique, Centre de Valduc, 21120 Is-sur-Tille (France)

    2009-07-01

    Several experimental devices are operated by the Criticality and Neutron Science Research Department of the CEA Valduc Laboratory. One of these is the metallic core reactor Caliban. The knowledge of the fundamental kinetic parameters of the reactor is very useful, indeed necessary, to the operator. The purpose of this study was to develop and perform experiments allowing to determinate some of these parameters. The prompt neutron decay constant and particularly its value at criticality can be measured with reactor noise techniques such as the interval-distribution, the Feynman variance-to-mean, and the Rossi-{alpha} methods. By introducing the Nelson number, the effective delayed neutron fraction and the average neutron lifetime can also be calculated with the Rossi-{alpha} method. Subcritical, critical, and even supercritical experiments were performed. With the Rossi-{alpha} technique, it was found that the prompt neutron decay constant at criticality was (6.02*10{sup 5} {+-} 9%). Experiments also brought out the limitations of the used experimental parameters. (authors)

  18. Three experimental tests of Bell's inequalities by measurement of polarization correlation of photons

    International Nuclear Information System (INIS)

    Aspect, A.

    1983-02-01

    We have performed three experimental tests of Bell's inequalities by measuring the linear-polarization correlation of photons emitted by pairs in the 4p 2 1 S 0 → 4s4p 1 P 1 → 4s 2 1 S 0 radiative cascade of calcium. The first part of this dissertation reminds the theoretical background (Bell's theorem), and the experimental situation (previous experiments). We then describe our apparatus: the source (calcium atomic beam selectively excited by two-photon absorption), the optics, the photon coincidence-counting system. Our first experiment, analogous to previous ones (but more precise) involves one-channel polarizers. Our second experiment, based on a conceptually simpler scheme, uses two-channel polarizers. The third experiment involves acousto-optical switches followed by two linear polarizers: these devices act as time-varying polarizers, the orientation of which is changed during the time of flight of photons. In the three experiments, the results are in good agreement with the Quantum mechanical predictions, and they distinctly violate the relevant Bell's inequalities [fr

  19. Measuring the Biodegradability of Plastic Polymers in Olive-Mill Waste Compost with an Experimental Apparatus

    Directory of Open Access Journals (Sweden)

    Francesco Castellani

    2016-01-01

    Full Text Available The use of biodegradable polymers is spreading in agriculture to replace those materials derived from petroleum, thus reducing the environmental concerns. However, to issue a significant assessment, biodegradation rate must be measured in case-specific standardized conditions. In accordance with ISO 14855-1, we designed and used an experimental apparatus to evaluate the biodegradation rate of three biopolymers based on renewable resources, two poly(ε-caprolactone (PCL composites, and a compatibilized polylactic acid and polybutyrate (PLA/PBAT blend. Biodegradation tests were carried out under composting condition using mature olive-mill waste (OMW compost as inoculum. Carbon dioxide emissions were automatically recorded by infrared gas detectors and also trapped in saturated Ba(OH2 solution and evaluated via a standard titration method to check the results. Some of the samples reached more than 80% biodegradation in less than 20 days. Both the experimental apparatus and the OMW compost showed to be suitable for the cases studied.

  20. Fluid dynamic design and experimental study of an aspirated temperature measurement platform used in climate observation

    International Nuclear Information System (INIS)

    Yang, Jie; Liu, Qingquan; Dai, Wei; Ding, Renhui

    2016-01-01

    Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors with a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.

  1. Fluid dynamic design and experimental study of an aspirated temperature measurement platform used in climate observation.

    Science.gov (United States)

    Yang, Jie; Liu, Qingquan; Dai, Wei; Ding, Renhui

    2016-08-01

    Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors with a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.

  2. Fluid dynamic design and experimental study of an aspirated temperature measurement platform used in climate observation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jie, E-mail: yangjie396768@163.com [Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration, Nanjing 210044 (China); School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044 (China); Liu, Qingquan [Jiangsu Key Laboratory of Meteorological Observation and Information Processing, Nanjing 210044 (China); Jiangsu Collaborative Innovation Center on Atmospheric Environment and Equipment Technology, Nanjing 210044 (China); Dai, Wei [School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044 (China); Ding, Renhui [Jiangsu Meteorological Observation Center, Nanjing 210008 (China)

    2016-08-15

    Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors with a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.

  3. Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

    Science.gov (United States)

    Schwarz, T; Weber, M; Wörner, M; Renkawitz, T; Grifka, J; Craiovan, B

    2017-05-01

    Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text

  4. Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, H.; Cloute-Cazalaa, V.; Salmon, L.

    2011-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  5. Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, Hubert; Cloute-Cazalaa, Veronique; Salmon, Laurent

    2012-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  6. Muon Lifetime Measurement and Introduction to the use of FPGAs in Experimental Physics

    International Nuclear Information System (INIS)

    Villasenor, L.

    2008-01-01

    During the laboratory sessions at the Workshop, the students used a simple experimental setup to measure the muon lifetime with a 10% statistical error. The muon detector consisted of a sealed container, filled with liquid scintillator, coupled to a 2.5'' photomultiplier (PMT). A personal computer (PC) was used to control a digital oscilloscope which directly measured the time interval between two consecutive PMT pulses in a time window of 20 μs. The students were also introduced to the use of root to analyze the muon data and to measure the muon lifetime. They were also presented with a basic introduction to the application of field-programmable gate arrays (FPGAs) in data acquisition (DAQ) systems by means of examples. We started with a brief introduction to the VHDL language and the software package used to program FPGAs and PROMs on a commercial FPGA development board. They learned to program FPGAs for handling data transfers using the RS-232 port of a PC. They were also introduced to the concepts of circular RAMs (Random Access Memory) and FIFO (First-In First-Out) memories in the context of fast and efficient DAQ systems. We emphasized the way in which inexpensive FPGA-based electronics replaces the use of traditionally used electronics modules, such as NIM, CAMAC, FASTBUS, VME, etc., to construct fast and powerful DAQ systems

  7. Measuring and modeling the temporal dynamics of nitrogen balance in an experimental-scale paddy field

    Science.gov (United States)

    Tseng, C.; Lin, Y.

    2013-12-01

    Nitrogen balance involves many mechanisms and plays an important role to maintain the function of nature. Fertilizer application in agriculture activity is usually seen as a common and significant nitrogen input to environment. Improper fertilizer application on paddy field can result in great amount of various types of nitrogen losses. Hence, it is essential to understand and quantify the nitrogen dynamics in paddy field for fertilizer management and pollution control. In this study, we develop a model which considers major transformation processes of nitrogen (e.g. volatilization, nitrification, denitrification and plant uptake). In addition, we measured different types of nitrogen in plants, soil and water at plant growth stages in an experimental-scale paddy field in Taiwan. The measurement includes total nitrogen in plants and soil, and ammonium-N (NH4+-N), nitrate-N (NO3--N) and organic nitrogen in water. The measured data were used to calibrate the model parameters and validate the model for nitrogen balance simulation. The results showed that the model can accurately estimate the temporal dynamics of nitrogen balance in paddy field during the whole growth stage. This model might be helpful and useful for future fertilizer management and pollution control in paddy field.

  8. Experimental measurements and finite element models of High Displacement Piezoelectric Actuators.

    Science.gov (United States)

    Camargo, Gilberto; Ashford, Gevale; Naco, Eris; Usher, Tim

    2004-03-01

    Piezoelectric actuators have many applications including morphable wing technology and piezoelectric transformers. A Piezoelectric ceramic is a material that will move when a voltage is applied and conversely produces a charge when a pressure is applied. In our study, we examine THUNDER (Thin Layer Unimorph Ferroelectric Driver and Sensor) actuators (Thunder TM is a trademark of FACE International Corporation.) Thunder actuators are constructed by bonding thin PZT piezoelectric ceramics to metal sheets. We will present physical measurements of piezoelectric actuators, as well as measurements of the displacements due to applied voltages. In our studies we used a laser micrometer to measure the dimensional characteristics of four sizes of THUNDER actuators including TH-8R, TH-9R, TH-10R, and finally the TH-11R. We also developed computer models using a commercial fine element modeling package (FEM) known as ANSYS6.0®. This software enables us to construct our models controlling such attributes as exact dimensions of the three layers of the piezoelectric actuator, the material properties of each element, the type of load that is to be applied as well as the manner in which the layers are bonded together. The computer model compares favorably with the experimental results. Acknowledgements: NASA Grant No. 0051-0078 Department of Defense (DoD) Control No.ISP02-EUG15

  9. Evaluation of Real-time Measurement Liver Tumor's Movement and SynchronyTM System's Accuracy of Radiosurgery using a Robot CyberKnife

    International Nuclear Information System (INIS)

    Kim, Gha Jung; Shim, Su Jung; Kim, Jeong Ho; Min, Chul Kee; Chung, Weon Kuu

    2008-01-01

    This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system (SynchronyTM). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and 13.9±5.5 mm, respectively from the superior to the inferior direction, 3.9 mm and 1.9±0.9 mm, respectively from left to right, and 8.3 mm and 4.9±1.9 mm, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be 3.3o and 2.6±1.3o, respectively for X (Left-Right) axis rotation, 4.8o and 2.3±1.0o, respectively for Y (Cranio-Caudal) axis rotation, 3.9o and 2.8±1.1o, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was 1.1±0.7 mm. Conclusion

  10. Experimental Measurement of Relative Permeability Functions for Fuel Cell GDL Materials

    KAUST Repository

    Hussaini, Irfan; Wang, Chao-Yang

    2009-01-01

    Gas diffusion layer in PEM fuel cells plays a pivotal role in water management. Modeling of liquid water transport through the GDL relies on knowledge of relative permeability functions in the in-plane and through-plane directions. In the present work, air and water relative permeabilities are experimentally determined as functions of saturation for typical GDL materials such as Toray-060, -090, -120 carbon paper and E-Tek carbon cloth materials in their plain, untreated forms. Saturation is measured using an ex-situ gravimetric method. Absolute and relative permeability functions in the two directions of interest are presented. Significant departure from the generally assumed cubic function of saturation is observed. ©The Electrochemical Society.

  11. Design, Specification and Construction of Specialized Measurement System in the Experimental Building

    Science.gov (United States)

    Fedorczak-Cisak, Malgorzata; Kwasnowski, Pawel; Furtak, Marcin; Hayduk, Grzegorz

    2017-10-01

    Experimental buildings for “in situ” research are a very important tool for collecting data on energy efficiency of the energy-saving technologies. One of the most advanced building of this type in Poland is the Maloposkie Laboratory of Energy-saving Buildings at Cracow University of Technology. The building itself is used by scientists as a research object and research tool to test energy-saving technologies. It is equipped with a specialized measuring system consisting of approx. 3 000 different sensors distributed in technical installations and structural elements of the building (walls, ceilings, cornices) and the ground. The authors of the paper will present the innovative design and technology of this specialized instrumentation. They will discuss issues arising during the implementation and use of the building.

  12. EXPERIMENTAL MEASUREMENT, ANALYSIS AND MODELLING OF DEPENDENCY EMISSIVITY IN FUNCTION OF TEMPERATURE

    Directory of Open Access Journals (Sweden)

    N. Baba Ahmed

    2015-08-01

    Full Text Available We propose a direct method of measurement of the total emissivity of opaque samples on a range of temperature around the ambient one. The method rests on the modulation of the temperature of the sample and the infra-red signal processing resulting from the surface of the sample we model the total emissivity obtained in experiments according to the temperature to establish linear correlations. This leads us to apply the method of optimal linearization associated the finite element method with the nonlinear problem of transfer of heat if thermal conductivity, the specific heat and the emissivity of studied material depend on the temperature. We obtain a good agreement between the resolution of the nonlinear equation of heat and the results obtained by the experimentation. .

  13. Experimental testing of the digital multichannel analyzer for gamma spectrometry measurements

    International Nuclear Information System (INIS)

    Novkovic, D.; Nadjdjerdj, L.; Kandic, A.; Vukanac, I.; Djurasevic, M.

    2008-01-01

    The results of experimental testing of the digital multichannel analyzer which digitalizes the signal after a preamplifier are presented. The recordings of some of the characteristics of the spectrometer containing a digital MCA, such as full-peak efficiency, net-area ratio of the two peaks and the stability of the peak position, were carried out under different input counting rates, with different radioactive sources. The tested MCA has shown some excellent features, like the stability of the peak position over a long-term period and flexibility in the adjusting of optimum measurement conditions. However, the performed tests have also shown some serious and unexpected disadvantages of the digital MCA when it operates under certain circumstances, one of them having to do with the automatic tuning of live-time correction at low-input counting rates. (author)

  14. Experimental Set-up and Full-scale measurements in the ‘Cube'

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    The Cube' is an outdoor test facility located at the main campus of Aalborg University. It has been built in the fall of 2005 with the purpose of detailed investigations of the DSF performance, development of the empirical test cases for validation and further improvements of various building...... of any power supplied to the experimental zone in order to maintain the necessary thermal conditions. An accuracy of these measurements is justified by the quality of the facility construction: ‘the Cube' is very well insulated and tight....... simulation software for the modelling of buildings with double skin facades in the frame of IEA ECBCS ANNEX 43/SHC Task 34, Subtask EDouble Skin Facade. The test facility is designed to be flexible for a choice of the DSF operational modes, natural or mechanical flow conditions, different types of shading...

  15. Comparison of Numerically Simulated and Experimentally Measured Performance of a Rotating Detonation Engine

    Science.gov (United States)

    Paxson, Daniel E.; Fotia, Matthew L.; Hoke, John; Schauer, Fred

    2015-01-01

    A quasi-two-dimensional, computational fluid dynamic (CFD) simulation of a rotating detonation engine (RDE) is described. The simulation operates in the detonation frame of reference and utilizes a relatively coarse grid such that only the essential primary flow field structure is captured. This construction and other simplifications yield rapidly converging, steady solutions. Viscous effects, and heat transfer effects are modeled using source terms. The effects of potential inlet flow reversals are modeled using boundary conditions. Results from the simulation are compared to measured data from an experimental RDE rig with a converging-diverging nozzle added. The comparison is favorable for the two operating points examined. The utility of the code as a performance optimization tool and a diagnostic tool are discussed.

  16. Solar intensity measurement using a thermoelectric module; experimental study and mathematical modeling

    International Nuclear Information System (INIS)

    Rahbar, Nader; Asadi, Amin

    2016-01-01

    Highlights: • Solar intensity could be explained as a linear function of voltage and ambient temperature. • The maximum output voltage is approximately 120 mV which was occurred in midday. • The average value of the heat-sink thermal resistance could be measured with this device. • The average values of total heat transfer coefficients could be measured with this device. • Two correlations were proposed to predict the solar intensity with the accuracy of 10%. - Abstract: The present study is intended to design, manufacture, and modeling an inexpensive pyranometer using a thermoelectric module. The governing equations relating the solar intensity, output voltage, and ambient temperature have been derived by applying the mathematical and thermodynamic models. According to the thermodynamics modeling, the output voltage is a function of solar intensity, ambient temperature, internal parameters of thermoelectric module, convection and radiation coefficients, and geometrical characteristics of the setup. Moreover, the solar intensity can be considered as a linear function of voltage and ambient temperature within an acceptable range of accuracy. The experiments have been carried out on a typical winter day under climatic conditions of Semnan (35°33′N, 53°23′E), Iran. The results also indicated that the output voltage is dependent on the solar intensity and its maximum value was 120 mV. Finally, based on the experimental results, two correlations, with the accuracy of 10%, have been proposed to predict the solar intensity as a function of output voltage and ambient temperature. The average values of total heat transfer coefficient and thermal resistance of the heat-sink have been also calculated according to the thermodynamic modeling and experimental results.

  17. Comparing renal function preservation after laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for clinical T1a renal tumor: using a 3D parenchyma measurement system.

    Science.gov (United States)

    Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin

    2017-05-01

    To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p renal parenchyma volume preservation (89.19 vs 84.27%, p renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.

  18. Methodology and experimental setup for measuring short-lives fission product yields in actinides induced fission by charged particles

    International Nuclear Information System (INIS)

    Bellido, A.V.

    1995-07-01

    The theoretical principles and the laboratory set-up for the fission products yields measurements are described. The procedures for the experimental determinations are explain in detail. (author). 43 refs., 5 figs

  19. Measurements of diagnostic examination performance using quantitative apparent diffusion coefficient and proton MR spectroscopic imaging in the preoperative evaluation of tumor grade in cerebral gliomas

    International Nuclear Information System (INIS)

    Server, Andres; Kulle, Bettina; Gadmar, Oystein B.; Josefsen, Roger; Kumar, Theresa; Nakstad, Per H.

    2011-01-01

    Purpose: Tumor grading is very important both in treatment decision and evaluation of prognosis. While tissue samples are obtained as part of most therapeutic approaches, factors that may result in inaccurate grading due to sampling error (namely, heterogeneity in tissue sampling, as well as tumor-grade heterogeneity within the same tumor specimen), have led to a desire to use imaging better to ascertain tumor grade. The purpose in our study was to evaluate the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the curve (AUC), and accuracy of diffusion-weighted MR imaging (DWI), proton MR spectroscopic imaging (MRSI) or both in grading primary cerebral gliomas. Materials and methods: We performed conventional MR imaging (MR), DWI, and MRSI in 74 patients with newly diagnosed brain gliomas: 59 patients had histologically verified high-grade gliomas: 37 glioblastomas multiform (GBM) and 22 anaplastic astrocytomas (AA), and 15 patients had low-grade gliomas. Apparent diffusion coefficient (ADC) values of tumor and peritumoral edema, and ADC ratios (ADC in tumor or peritumoral edema to ADC of contralateral white matter, as well as ADC in tumor to ADC in peritumoral edema) were determined from three regions of interest. The average of the mean, maximum, and minimum for ADC variables was calculated for each patient. The metabolite ratios of Cho/Cr and Cho/NAA at intermediate TE were assessed from spectral maps in the solid portion of tumor, peritumoral edema and contralateral normal-appearing white matter. Tumor grade determined with the two methods was then compared with that from histopathologic grading. Logistic regression and receiver operating characteristic (ROC) curve analysis were performed to determine optimum thresholds for tumor grading. Measures of diagnostic examination performance, such as sensitivity, specificity, PPV, NPV, AUC, and accuracy for identifying high-grade gliomas were also calculated

  20. Experimental measurements of thermoelectric and electrochemical potentials in sandstones saturated with NaCl electrolyte

    Science.gov (United States)

    Leinov, E.; Jackson, M.

    2013-12-01

    Measurements of the self-potential (SP) have been used to characterize subsurface flow in numerous settings, including volcanoes, earthquake zones, and geothermal fields. Thermoelectric (TE) and electrochemical (EC) potentials contribute to the measured SP if gradients in temperature and/or concentration are present, yet few experimental measurements of EC and TE potentials in natural porous media have been reported. Each is the sum of a diffusion and exclusion potential: the former arises when ions of contrasting mobility migrate at different rates down a temperature or concentration gradient; the latter arises when there is a temperature or concentration gradient across an electrically charged porous medium in which co-ions of the same polarity have been excluded from the pore-space. Here we report measurements of the SP arising from temperature or concentration gradients across clean (clay-free) sandstone samples saturated with NaCl electrolyte over the salinity range 5x10-5 to 1M. Electrical potentials are measured using non-polarizing Ag/AgCl electrodes, and temperature or salinity gradients are induced by placing the saturated samples in contact with electrolyte reservoirs of contrasting temperature or concentration. Our experimental methodology accounts for the temperature- and concentration-dependent electrode response. We find that the TE potential responds linearly to the applied temperature difference, allowing a TE potential coupling coefficient to be determined; the value of this decreases as the electrolyte concentration increases, from +0.056mV/K at 10-4 M to -0.126mV/K at 1M. The EC potential increases as the concentration ratio increases, from a minimum of 1.8mV at a salinity ratio of 1.13, to a maximum of 24.8mV at salinity ratio of 102, before decreasing to 19.5mV at salinity ratio of 103. In both cases, at high values of concentration (>0.01M) the measured potential is diffusion dominated, while at lower concentration the exclusion potential is

  1. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  2. Radio-frequency ablation in patients with malignant hepatic tumor and experimental model: comparison of expandable needle and water-cooled needle

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Yong Ju; Jeong, Yong Yeon; Kim, Jeong; Yim, Nam yeol; Kang, Heoung Keun [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of); Kim, Eun Ha; Yoon, Kwon Ha [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Ko, Seog Wan [School of Medicine, Chonbuk National Univ., Jeonju (Korea, Republic of)

    2004-12-01

    The purpose of this study was to compare the shape and volume of the radio-frequency induced lesions produced by two commercially available radio-frequency ablation (RFA) systems, the expandable and cooled-tip needles, in clinical patients and an experimental model. A twelve-array anchor expandable needle electrode and a single cooled-tip needle electrode were used to treat hepatic tumors with a single session in 23 patients (20 hepatocellular carcinomas and 3 hepatic metastases) and fourteen patients (10 hepatocellular carcinomas and 4 hepatic metastases), respectively. Twenty RFA induced lesions were created with each system in 10 explanted bovine livers. The shape of the RFA induced lesions were divided into oval lesions along or perpendicular to the axis of the electrode and spherical lesions, and we then calculated the volumes of the RFA induced lesions. Fourteen (61%) lesions of the 23 patients treated with the expandable system were oval perpendicular to the axis of the electrode and nine (39%) of the lesions were spherical. All the lesions (100%) of the 14 patients treated with the cooled-tip needle were ovaI along the axis of the electrode. In the ex vivo bovine livers, the shape of the all RFA induced lesions was oval perpendicular to the axis of the electrode for the expandable needle, and oval along the axis of the electrode for the cooled-tip needle. The mean diameter and volume of the RFA induced lesions in the patients were 3.35{+-}0.56 cm and 19.9{+-}6.53 cm{sup 3}, respectively, for the expandable needle and 3.58{+-}0.78 cm and 23.19{+-}5.27 cm{sup 3}, respectively, for the cooled-tip needle. In the ex vivo model, the mean diameter and volume of RFA induced lesions were 3.41{+-}0.59 cm and 26.59{+-}8.02 cm{sup 3}, respectively, for the expandable needle, and 4.04{+-}0.65 cm and 33.82{+-}6.16 cm{sup 3}, respectively, for the cooled-tip needle (p <0.05). These results indicate that the shape of RFA induced lesions with the expandable needle were oval

  3. Assessment of CANDU physics codes using experimental data - II: CANDU core physics measurements

    International Nuclear Information System (INIS)

    Roh, Gyu Hong; Jeong, Chang Joon; Choi, Hang Bok

    2001-11-01

    Benchmark calculations of the advanced CANDU reactor analysis tools (WIMS-AECL, SHETAN and RFSP) and the Monte Carlo code MCNP-4B have been performed using Wolsong Units 2 and 3 Phase-B measurement data. In this study, the benchmark calculations have been done for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. For the validation of the WIMS-AECL/SHETANRFSP code system, the lattice parameters of the fuel channel were generated by the WIMS-AECL code, and incremental cross sections of reactivity devices and structural material were generated by the SHETAN code. The results have shown that the criticality is under-predicted by -4 mk. The reactivity device worths are generally consistent with the measured data except for the strong absorbers such as shutoff rod and mechanical control absorber. The heat transport system temperature coefficient and flux distributions are in good agreement with the measured data. However, the moderator temperature coefficient has shown a relatively large error, which could be caused by the incremental cross-section generation methodology for the reactivity device. For the MCNP-4B benchmark calculation, cross section libraries were newly generated from ENDF/B-VI release 3 through the NJOY97.114 data processing system and a three-dimensional full core model was developed. The simulation results have shown that the criticality is estimated within 4 mk and the estimated reactivity worth of the control devices are generally consistent with the measurement data, which implies that the MCNP code is valid for CANDU core analysis. In the future, therefore, the MCNP code could be used as a reference tool to benchmark design and analysis codes for the advanced fuels for which experimental data are not available

  4. An experimental setup for visualizations and measurements on free hypersonic jets

    Directory of Open Access Journals (Sweden)

    Tordella Daniela

    2012-04-01

    Full Text Available The free hypersonic jets can be found in several technological applications and even in astrophysical observations. This article is mainly devoted to explain an experiment about visualizations and measurements on free hypersonic jets extending on length scales in the order of hundreds of initial diameters and traveling in a medium not necessarily made of the same gas of the jets. The experiments are performed by means of special facilities where the jet Mach numbers and the jetto-ambient density ratios can be set independently of each other, what permits the investigation of a wide parameters range in the relevant physics. The Mach number of the jets ranges from 5 to 20 and the jet-to ambient density ratio, which plays an important role in the jets morphology, can be set from 0.1 up to values exceeding 100. The present setup produces the jets by means of a fast piston system (for high Mach numbers or injection valves (for low Mach numbers, both coupled with de Laval nozzles. The visualizations and measurements are based on the electron beam technique: the jets are weakly ionized, then a fast CMOS camera captures images that are analyzed by image processing techniques. A sample of the results obtained by this experimental system is included at the end of this work.

  5. Accurate Profile Measurement of the low Intensity Secondary Beams in the CERN Experimental Areas

    CERN Document Server

    AUTHOR|(CDS)2084531; Tranquille, Gerard

    2018-02-23

    The CERN accelerators deliver a wide spectrum of secondary beams to the Experimental Areas. These beams are composed of hadrons, leptons, and heavy ions that can vary greatly in momentum (1 GeV/c to 400 GeV/c) and intensity (10^2 to 10^8 particles per second). The profile, position, and intensity of these beams are measured utilising particle detectors. However, the current systems show several problems that limit the quality of this kind of monitoring. The aim of this doctoral thesis is to investigate the best detector technology that could replace the existing monitors and build a first prototype of it. A review of the existing detection techniques has led to the choice of Scintillating Fibres (SciFi) read-out with Silicon Photomultipliers (SiPM). This detection technology has the potential to perform better in terms of material budget, range of intensities measured, and active area size. In addition, it has particle counting capabilities, which could extend its application to momentum spectrometry or Time...

  6. Monte Carlo calculations and experimental