WorldWideScience

Sample records for experimental valve disease

  1. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  2. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    Science.gov (United States)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  3. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  4. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  5. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  6. Aortic Valve Disease

    Science.gov (United States)

    ... team will discuss with you the advantages and disadvantages of both valve types. Regardless of which type ... Diagnosis and Treatment Options Recovery Questions for Your Doctor Will my condition ever get better without treatment? ...

  7. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  8. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  9. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  10. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  11. Heart valve disease among patients with hyperprolactinemia

    DEFF Research Database (Denmark)

    Steffensen, Maria Charlotte; Maegbaek, Merete Lund; Laurberg, Peter

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  12. Experimental research of flow servo-valve

    Directory of Open Access Journals (Sweden)

    Takosoglu Jakub

    2017-01-01

    Full Text Available Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  13. Experimental research of flow servo-valve

    Science.gov (United States)

    Takosoglu, Jakub

    Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  14. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  15. Emerging Trends in Heart Valve Engineering: Part IV. Computational Modeling and Experimental Studies.

    Science.gov (United States)

    Kheradvar, Arash; Groves, Elliott M; Falahatpisheh, Ahmad; Mofrad, Mohammad K; Hamed Alavi, S; Tranquillo, Robert; Dasi, Lakshmi P; Simmons, Craig A; Jane Grande-Allen, K; Goergen, Craig J; Baaijens, Frank; Little, Stephen H; Canic, Suncica; Griffith, Boyce

    2015-10-01

    In this final portion of an extensive review of heart valve engineering, we focus on the computational methods and experimental studies related to heart valves. The discussion begins with a thorough review of computational modeling and the governing equations of fluid and structural interaction. We then move onto multiscale and disease specific modeling. Finally, advanced methods related to in vitro testing of the heart valves are reviewed. This section of the review series is intended to illustrate application of computational methods and experimental studies and their interrelation for studying heart valves.

  16. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  17. Multimodality Imaging of Heart Valve Disease

    International Nuclear Information System (INIS)

    Rajani, Ronak; Khattar, Rajdeep; Chiribiri, Amedeo; Victor, Kelly; Chambers, John

    2014-01-01

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses

  18. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  19. Simple versus complex degenerative mitral valve disease.

    Science.gov (United States)

    Javadikasgari, Hoda; Mihaljevic, Tomislav; Suri, Rakesh M; Svensson, Lars G; Navia, Jose L; Wang, Robert Z; Tappuni, Bassman; Lowry, Ashley M; McCurry, Kenneth R; Blackstone, Eugene H; Desai, Milind Y; Mick, Stephanie L; Gillinov, A Marc

    2018-07-01

    At a center where surgeons favor mitral valve (MV) repair for all subsets of leaflet prolapse, we compared results of patients undergoing repair for simple versus complex degenerative MV disease. From January 1985 to January 2016, 6153 patients underwent primary isolated MV repair for degenerative disease, 3101 patients underwent primary isolated MV repair for simple disease (posterior prolapse), and 3052 patients underwent primary isolated MV repair for complex disease (anterior or bileaflet prolapse), based on preoperative echocardiographic images. Logistic regression analysis was used to generate propensity scores for risk-adjusted comparisons (n = 2065 matched pairs). Durability was assessed by longitudinal recurrence of mitral regurgitation and reoperation. Compared with patients with simple disease, those undergoing repair of complex pathology were more likely to be younger and female (both P values < .0001) but with similar symptoms (P = .3). The most common repair technique was ring/band annuloplasty (3055/99% simple vs 3000/98% complex; P = .5), followed by leaflet resection (2802/90% simple vs 2249/74% complex; P < .0001). Among propensity-matched patients, recurrence of severe mitral regurgitation 10 years after repair was 6.2% for simple pathology versus 11% for complex pathology (P = .007), reoperation at 18 years was 6.3% for simple pathology versus 11% for complex pathology, and 20-year survival was 62% for simple pathology versus 61% for complex pathology (P = .6). Early surgical intervention has become more common in patients with degenerative MV disease, regardless of valve prolapse complexity or symptom status. Valve repair was associated with similarly low operative risk and time-related survival but less durability in complex disease. Lifelong annual echocardiographic surveillance after MV repair is recommended, particularly in patients with complex disease. Copyright © 2018 The American Association for Thoracic Surgery

  20. Myxomatous mitral valve disease in dogs - an update and perspectives

    Directory of Open Access Journals (Sweden)

    Aleksandra Domanjko Petrič

    2015-03-01

    Full Text Available Myxomatous mitral valve disease is a common cause of congestive heart failure in geriatric dogs. Many studies have been done in terms of epidemiology, pathology, associated neurohormonal changes in the disease progression, prognostic factors, and survival and treatment modalities. The presented paper presents a review of some of the studies in the mitral valve disease story.

  1. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    Science.gov (United States)

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  2. Inhibitory role of Notch1 in calcific aortic valve disease.

    Directory of Open Access Journals (Sweden)

    Asha Acharya

    Full Text Available Aortic valve calcification is the most common form of valvular heart disease, but the mechanisms of calcific aortic valve disease (CAVD are unknown. NOTCH1 mutations are associated with aortic valve malformations and adult-onset calcification in families with inherited disease. The Notch signaling pathway is critical for multiple cell differentiation processes, but its role in the development of CAVD is not well understood. The aim of this study was to investigate the molecular changes that occur with inhibition of Notch signaling in the aortic valve. Notch signaling pathway members are expressed in adult aortic valve cusps, and examination of diseased human aortic valves revealed decreased expression of NOTCH1 in areas of calcium deposition. To identify downstream mediators of Notch1, we examined gene expression changes that occur with chemical inhibition of Notch signaling in rat aortic valve interstitial cells (AVICs. We found significant downregulation of Sox9 along with several cartilage-specific genes that were direct targets of the transcription factor, Sox9. Loss of Sox9 expression has been published to be associated with aortic valve calcification. Utilizing an in vitro porcine aortic valve calcification model system, inhibition of Notch activity resulted in accelerated calcification while stimulation of Notch signaling attenuated the calcific process. Finally, the addition of Sox9 was able to prevent the calcification of porcine AVICs that occurs with Notch inhibition. In conclusion, loss of Notch signaling contributes to aortic valve calcification via a Sox9-dependent mechanism.

  3. Animal Models of Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Krista L. Sider

    2011-01-01

    Full Text Available Calcific aortic valve disease (CAVD, once thought to be a degenerative disease, is now recognized to be an active pathobiological process, with chronic inflammation emerging as a predominant, and possibly driving, factor. However, many details of the pathobiological mechanisms of CAVD remain to be described, and new approaches to treat CAVD need to be identified. Animal models are emerging as vital tools to this end, facilitated by the advent of new models and improved understanding of the utility of existing models. In this paper, we summarize and critically appraise current small and large animal models of CAVD, discuss the utility of animal models for priority CAVD research areas, and provide recommendations for future animal model studies of CAVD.

  4. Fibrinogen and fibronectin binding cooperate for valve infection and invasion in Staphylococcus aureus experimental endocarditis

    NARCIS (Netherlands)

    Que, Yok-Ai; Haefliger, Jacques-Antoine; Piroth, Lionel; François, Patrice; Widmer, Eleonora; Entenza, José M; Sinha, Bhanu; Herrmann, Mathias; Francioli, Patrick; Vaudaux, Pierre; Moreillon, Philippe

    2005-01-01

    The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected

  5. Experimental validation of the fluid–structure interaction simulation of a bioprosthetic aortic heart valve

    International Nuclear Information System (INIS)

    Kemp, I.; Dellimore, K.; Rodriguez, R.; Scheffer, C.; Blaine, D.; Weich, H.; Doubell, A.

    2013-01-01

    Experiments performed on a 19 mm diameter bioprosthetic valve were used to successfully validate the fluid–structure interaction (FSI) simulation of an aortic valve at 72 bpm. The FSI simulation was initialized via a novel approach utilizing a Doppler sonogram of the experimentally tested valve. Using this approach very close quantitative agreement (≤12.5 %) between the numerical predictions and experimental values for several key valve performance parameters, including the peak systolic transvalvular pressure gradient, rapid valve opening time and rapid valve closing time, was obtained. The predicted valve leaflet kinematics during opening and closing were also in good agreement with the experimental measurements.

  6. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  7. Canine Degenerative Valve Disease: A Case Report

    Directory of Open Access Journals (Sweden)

    Carmenza Janneth Benavides Melo

    2014-07-01

    Full Text Available Degenerative valvular disease or endocardiosis is the most common cardiovascular pathology in dogs. It is characterized by regurgitation of blood into the atria with decreased cardiac output, leading to volume overload with eccentric hypertrophy and congestive heart failure. This report describes the clinical and autopsy findings of a dog, suggestive of valvular endocardiosis. The patient was admitted to the outpatient Veterinary Clinic “Carlos Martínez Hoyos” at the University of Nariño (Pasto, Colombia. His owner said the dog was sick for two months, with signs of respiratory disease, weight loss, and decay. Clinical examination showed very pale mucous membranes, inspiratory dyspnea, rale, split S2, grade 4 mid-systolic murmur of regurgitation, and abdominal dilatation with sign of positive shock wave. Necropsy evidenced plenty of translucent watery material in the abdominal, chest and pericardium cavity, severely enlarged and rounded heart with thickened atrioventricular valves, moderate reduction in liver size and signs of lobulation, severely diminished and pale kidneys with irregular surface showing the presence of multiple cystic areas in corticomedullary region. Samples were taken from these tissues and fixed in 10% buffered formalin to be processed for histopathological analysis at the Laboratory of Pathology at the University of Nariño, using hematoxylin and eosin stain. This way, degenerative valvular disease was diagnosed.

  8. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  9. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  10. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  11. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  12. Surgery for rheumatic mitral valve disease in sub-saharan African ...

    African Journals Online (AJOL)

    However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, ...

  13. Experimental study for flow characteristics and performance evaluation of butterfly valves

    International Nuclear Information System (INIS)

    Kim, C K; Shin, M S; Yoon, J Y

    2010-01-01

    The industrial butterfly valves have been applied to transport a large of fluid with various fields of industry. Also, these are mainly used a control of fluid flux to the water and waste-water pipeline. Present, butterfly valves are manufacturing for multiplicity shape of bodies and discs with many producers. However, appropriate performance evaluation was not yet accomplished to compare about these valves through experiments. This study is performed the experiment of flow characteristics and performance of manufactured 400A butterfly valves for the water and waste pipeline, and compared experimental results. We performed experiments that were controlled fixed a differential pressure condition (1 psi) and the range of the flow rate conditions (500 m 3 /hr ∼ 2500 m 3 /hr), and also opened the disc of valves to a range of angle from 9 degree to 90 degree. We investigated and compared the valve flow coefficient and the valve loss coefficient of results through experiments with each butterfly valve.

  14. Experimental investigation of the check valve behaviour when the flow is reversing

    Directory of Open Access Journals (Sweden)

    Himr D.

    2017-01-01

    Full Text Available Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.

  15. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  16. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  17. Congenital tricuspid valve disease and testicular agenesis: a case ...

    African Journals Online (AJOL)

    This is a report of a case of congenital tricuspid valve disease presenting with heart failure and pulmonary hypertension. Cardinal clinical features include breathlessness, easy fatigability since childhood, stunted growth, cyanosis, finger clubbing, a pansystolic murmur loudest at the left sternal edge in the fourth intercostal ...

  18. Effects of right ventricular morphology and function on outcomes of patients with degenerative mitral valve disease.

    Science.gov (United States)

    Ye, Ying; Desai, Ravi; Vargas Abello, Lina M; Rajeswaran, Jeevanantham; Klein, Allan L; Blackstone, Eugene H; Pettersson, Gösta B

    2014-11-01

    The study objective was to investigate whether, in patients undergoing surgery for degenerative mitral valve disease, associated right ventricular remodeling and dysfunction are stronger determinants of preoperative organ dysfunction and prognosis than functional tricuspid regurgitation. From January 2001 to January 2011, 4197 patients underwent primary mitral valve surgery for degenerative valve disease at Cleveland Clinic. Using a quasi-experimental enriched study design, 781 patients were randomly selected within each grade of functional tricuspid regurgitation. Renal function was assessed by glomerular filtration rate and blood urea nitrogen, and hepatic function was assessed by Model for End-stage Liver Disease (MELD) score. Preoperative and postoperative right ventricular morphology and function were measured de novo on stored echocardiographic images. To assess survival, 3471 patient-years of follow-up data were available for analysis. Several preoperative right ventricular variables, but not functional tricuspid regurgitation grade (P>.05), were associated with preoperative renal and hepatic dysfunction, but neither was associated with early mortality (.2), was among the risk factors for later mortality. Postoperative unadjusted right ventricular function, but not functional tricuspid regurgitation grade (P≥.2), was associated with both early (P=.04) and later (P=.01) mortality, but in multivariable analysis appeared to be a surrogate for worse preoperative condition. Together with patient comorbidities and operative factors, right ventricular morphology and function are associated more strongly with preoperative organ dysfunction and prognosis than is functional tricuspid regurgitation severity in patients undergoing surgery for degenerative mitral valve disease. Our previous study showed that tricuspid valve repair remains the most effective treatment to improve right ventricular function. Copyright © 2014 The American Association for Thoracic Surgery

  19. Outcome of double vs. single valve replacement for rheumatic heart disease

    International Nuclear Information System (INIS)

    Akhtar, R.P.; Abid, A.R.

    2010-01-01

    To compare the follow-up results of double valve replacement (DVR) i.e. mitral valve replacement (MVR) and aortic valve replacement (AVR) vs. isolated MVR or AVR for rheumatic heart disease. Study Design: An interventional qausi-experimental study. Prospective follow-up of 493 patients with mechanical heart valves was carried out using clinical assessment, international normalized ratio and echocardiography. Patients were divided into three groups: group I having MVR, group II having AVR and group III having DVR. Survival, time and causes of mortality, and frequency of valve thrombosis, haemorrhage and cerebrovascular haemorrhage was noted in the three groups and described as proportions. Actuarial survival was analyzed by Kaplan-Meier method. There were 493 with 287 (58.3%) in group I, 87 (17.6%) in group II and 119 (24.1%) in group III. Total follow-up was 2429.2 patient (pt)-years. Of 77 (15.6%) deaths, 19 (3.8%) were in-hospital and 58 (11.8%) were late. In-hospital mortality was highest 4 (4.6%) in group II followed by 5 (4.2%) group III and 10 (3.5%) group I. Late deaths were 39 (13.4%) in group I, 9 (10.2%) in group II and 10 (8.3%) in group III. The total actuarial survival was 84.4% with survival of 83%, 85.1%, 87.4% in groups I, II and III respectively. On follow-up valve thrombosis occurred in 12 (0.49%/pt-years) patients; 9 (0.67%/pt-years) group I, 1 (0.22%/pt-years) in group II and 2 (0.31%/pt-years) in group III. Severe haemorrhage occurred in 19 (0.78%/pt-years); 14 in (1.04%/pt-years) in group I, 3 (0.66%/pt-years) group II and 2 (0.31%/pt-years) in group III. Cerebrovascular accidents occurred in 34 (1.3%/pt-years); 26 (1.95%/pt-years) in group I and 4 in groups II (0.89%/pt-years) and III (0.62%/pt-years) each. In patients with rheumatic heart disease having combined mitral and aortic valve disease DVR should be performed whenever indicated as it has similar in-hospital mortality and better late survival as compared to isolated aortic or mitral

  20. Durability of mitral valve repair for mitral regurgitation due to degenerative mitral valve disease.

    Science.gov (United States)

    David, Tirone E

    2015-09-01

    Degenerative diseases of the mitral valve (MV) are the most common cause of mitral regurgitation in the Western world and the most suitable pathology for MV repair. Several studies have shown excellent long-term durability of MV repair for degenerative diseases. The best follow-up results are obtained with isolated prolapse of the posterior leaflet, however even with isolated prolapse of the anterior leaflet or prolapse of both leaflets the results are gratifying, particularly in young patients. The freedom from reoperation on the MV at 15 years exceeds 90% for isolated prolapse of the posterior leaflet and it is around 70-85% for prolapse of the anterior leaflet or both leaflets. The degree of degenerative change in the MV also plays a role in durability of MV repair. Most studies have used freedom from reoperation to assess durability of the repair but some studies that examined valve function late after surgery suggest that recurrent mitral regurgitation is higher than estimated by freedom from reoperation. We can conclude that MV repair for degenerative mitral regurgitation is associated with low probability of reoperation for up to two decades after surgery. However, almost one-third of the patients develop recurrent moderate or severe mitral regurgitation suggesting that surgery does not arrest the degenerative process.

  1. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  2. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  3. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  4. Experimental and analytical studies on waterhammer generated by the closing of check valves

    International Nuclear Information System (INIS)

    Huet, J.L.; Garcia, J.L.; Coppolani, P.; Ziegler, B.

    1987-01-01

    A double-guillotine rupture on a water line upstream from a check valve generates a severe transient between the check valve and the pressure vessel on the downstream side. Successively following phenomena occur: - decrease then reversal of the flow, - closing of the check valve with impact of the plug on its seat, - waterhammer propagating in the pipe downstream from the check valve. The COMMISARIAT A L'ENERGIE ATOMIQUE (C.E.A.) FRAMATOME and ELECTRICITE DE FRANCE (E.D.F.) have undertaken a joint program in order to: - investigate the behavior uf the check valve in the event of a sudden closure, - evaluate the pressure and flow transient in the line. The program includes: - full scale tests in two loops, CLAUDIA (C.E.A.) and ECLAIR (E.D.F.), - analytical studies in order to qualify the calculation codes. This paper describes the experimental program and presents the analysis results for a benchmark test

  5. Valve Repair Is Superior to Replacement in Most Patients With Coexisting Degenerative Mitral Valve and Coronary Artery Diseases.

    Science.gov (United States)

    Javadikasgari, Hoda; Gillinov, A Marc; Idrees, Jay J; Mihaljevic, Tomislav; Suri, Rakesh M; Raza, Sajjad; Houghtaling, Penny L; Svensson, Lars G; Navia, José L; Mick, Stephanie L; Desai, Milind Y; Sabik, Joseph F; Blackstone, Eugene H

    2017-06-01

    For mitral regurgitation (MR) from degenerative mitral disease in patients with coexisting coronary artery disease, the appropriate surgical strategy remains controversial. From 1985 to 2011, 1,071 adults (age 70 ± 9.3 years, 77% men) underwent combined coronary artery bypass grafting and either mitral valve repair (n = 872, 81%) or replacement (n=199, 19%) for degenerative MR. Propensity matching (177 patient pairs, 89% of possible matches) was used to compare early outcomes and time-related recurrence of MR after mitral valve repair, mitral valve reoperation, and mortality. Risk factors for death were identified with multivariable, multiphase hazard-function analysis. Patients undergoing valve replacement were older, with more valve calcification and a higher prevalence of preoperative atrial fibrillation and heart failure (all p < .0001). Among matched pairs, mitral replacement versus repair was associated with higher hospital mortality (5.0% vs 1.0%, p = .0001) and more postoperative renal failure (7.0% vs 3.2%, p = .01), reexplorations for bleeding (6.0% vs 3.1%, p = .05), and respiratory failure (14% vs 4.7%, p < .0001). Of matched patients undergoing repair, 18% had MR above 3+ by 5 years. Mitral valve durability was similar between matched groups, but survival at 15 years was 18% after replacement versus 52% after repair. Nomograms from the multivariable equation revealed that in 94% of cases, 10-year survival was calculated to be higher after repair than after replacement. In patients with coexisting degenerative mitral valve and coronary artery diseases, mitral valve repair is expected to confer a long-term survival advantage over replacement despite some recurrence of MR. When feasible, it is the procedure of choice for these patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  7. Experimental study on the effect of an artificial cardiac valve on the left ventricular flow

    Science.gov (United States)

    Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun

    2017-09-01

    The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.

  8. Experimental Validation of Flow Force Models for Fast Switching Valves

    DEFF Research Database (Denmark)

    Bender, Niels Christian; Pedersen, Henrik Clemmensen; Nørgård, Christian

    2017-01-01

    This paper comprises a detailed study of the forces acting on a Fast Switching Valve (FSV) plunger. The objective is to investigate to what extend different models are valid to be used for design purposes. These models depend on the geometry of the moving plunger and the properties of the surroun......This paper comprises a detailed study of the forces acting on a Fast Switching Valve (FSV) plunger. The objective is to investigate to what extend different models are valid to be used for design purposes. These models depend on the geometry of the moving plunger and the properties...... to compare and validate different models, where an effort is directed towards capturing the fluid squeeze effect just before material on material contact. The test data is compared with simulation data relying solely on analytic formulations. The general dynamics of the plunger is validated...

  9. Experimental research and numerical simulation on flow resistance of integrated valve

    International Nuclear Information System (INIS)

    Cai Wei; Bo Hanliang; Qin Benke

    2008-01-01

    The flow resistance of the integrated valve is one of the key parameters for the design of the control rod hydraulic drive system (CRHDS). Experimental research on the improved new integrated valve was performed, and the key data such as pressure difference, volume flow, resistance coefficient and flow coefficient of each flow channel were obtained. With the computational fluid dynamics software CFX, numerical simulation was executed to analyze the effect of Re on the flow resistance. On the basis of experimental and numerical results, fitting empirical formulas of resistance coefficient were obtained, which provide experimental and theoretical foundations for CRHDS's optimized design and theoretical analysis. (authors)

  10. Developmental basis for filamin-A-associated myxomatous mitral valve disease

    Science.gov (United States)

    Sauls, Kimberly; de Vlaming, Annemarieke; Harris, Brett S.; Williams, Katherine; Wessels, Andy; Levine, Robert A.; Slaugenhaupt, Susan A.; Goodwin, Richard L.; Pavone, Luigi Michele; Merot, Jean; Schott, Jean-Jacques; Le Tourneau, Thierry; Dix, Thomas; Jesinkey, Sean; Feng, Yuanyi; Walsh, Christopher; Zhou, Bin; Baldwin, Scott; Markwald, Roger R.; Norris, Russell A.

    2012-01-01

    Aims We hypothesized that the structure and function of the mature valves is largely dependent upon how these tissues are built during development, and defects in how the valves are built can lead to the pathological progression of a disease phenotype. Thus, we sought to uncover potential developmental origins and mechanistic underpinnings causal to myxomatous mitral valve disease. We focus on how filamin-A, a cytoskeletal binding protein with strong links to human myxomatous valve disease, can function as a regulatory interface to control proper mitral valve development. Methods and results Filamin-A-deficient mice exhibit abnormally enlarged mitral valves during foetal life, which progresses to a myxomatous phenotype by 2 months of age. Through expression studies, in silico modelling, 3D morphometry, biochemical studies, and 3D matrix assays, we demonstrate that the inception of the valve disease occurs during foetal life and can be attributed, in part, to a deficiency of interstitial cells to efficiently organize the extracellular matrix (ECM). This ECM organization during foetal valve gestation is due, in part, to molecular interactions between filamin-A, serotonin, and the cross-linking enzyme, transglutaminase-2 (TG2). Pharmacological and genetic perturbations that inhibit serotonin-TG2-filamin-A interactions lead to impaired ECM remodelling and engender progression to a myxomatous valve phenotype. Conclusions These findings illustrate a molecular mechanism by which valve interstitial cells, through a serotonin, TG, and filamin-A pathway, regulate matrix organization during foetal valve development. Additionally, these data indicate that disrupting key regulatory interactions during valve development can set the stage for the generation of postnatal myxomatous valve disease. PMID:22843703

  11. Experimental And Numerical Investigation Of The Flow Analysis Of The Water-Saving Safety Valve

    Directory of Open Access Journals (Sweden)

    Muhammed Safa Kamer

    2015-08-01

    Full Text Available Abstract In this study an auto-mechanical safety valve was designed and manufactured in order to prevent possible wastage of water and water raid after instantaneous water cuts during water usage in places where water use is widespread. Safety valve is activated and it switches off the line when water is cut off when mains pressure is equal to atmospheric pressure and as it does not allow water to pass when it comes back it saves water and prevents the formation of raids. An experiment set was conducted in order to measure the pressure drop between the inlet and outlet of the safety valve and it was found that with the increased flow rate the pressure drop increases. The three-dimensional flow analysis of the safety valve was carried out with Ansys-Fluent software package and the results obtained were compared with experimental data and a good harmony was achieved.

  12. Increased amount of atrial fibrosis in patients with atrial fibrillation secondary to mitral valve disease

    NARCIS (Netherlands)

    Geuzebroek, Guillaume S. C.; van Amersfoorth, Shirley C. M.; Hoogendijk, Mark G.; Kelder, Johannes C.; van Hemel, Norbert M.; de Bakker, Jacques M. T.; Coronel, Ruben

    2012-01-01

    Objective: Atrial fibrosis is related to atrial fibrillation but may differ in patients with mitral valve disease or lone atrial fibrillation. Therefore, we studied atrial fibrosis in patients with atrial fibrillation + mitral valve disease or with lone atrial fibrillation and compared it with

  13. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Melle, van Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie P. J.; Jongbloed, Monique R. M.; Post, Martijn C.; Sieswerda, Gertjan T.; in 't Veld, Anna Huis; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    Objectives To report the prevalence of aortic valve prosthesis patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis

  14. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; van Melle, Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C.; Sieswerda, Gertjan T.; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in

  15. Numerical and experimental investigation on the performance of safety valves operating with different gases

    International Nuclear Information System (INIS)

    Dossena, V.; Marinoni, F.; Bassi, F.; Franchina, N.; Savini, M.

    2013-01-01

    A detailed analysis of the effect related to the expansion of different gases throughout safety relief valves is carried out both numerically and experimentally. The considered gases are air, argon and ethylene, representative of a wide range of specific heat ratios. A first experimental campaign performed in air and argon on a safety relief valve characterized by connection 1/2″ × 1″ and orifice designation D (diameter 10 mm) according to API 526 showed significant reduction both in disc lift and in exhausted mass flow rate, at the nominal overpressure, when operating with argon. In order to gain a deeper insight into the physics involved and to evaluate the valve behavior with other gases, an extensive numerical testing has been performed by means of an accurate CFD code based on discontinuous Galerkin formulation. Numerical results are at first validated against measurements obtained in air on a 2″ J 3″ safety relief valve proving a remarkable accuracy of the computational method. Then the validated solver is applied on the same computational grid using argon and ethylene as working fluids. The three gases are considered as thermally perfect gases. A critical discussion based on the numerical results allows to clarify the fluid dynamic and physical reasons causing the observed trends both in the opening force and in the discharge coefficient. The main conclusion is that particular care must be taken when a safety valve operates with a fluid characterized by a specific heat ratio greater than the one of the gas used during type testing. -- Highlights: ► Effects of different gases on the discharge capacity and operational characteristics on safety relief valves. ► Influence of different specific heat ratio on safety relief valves discharge coefficient. ► Skilful application of Discontinuous Galerkin CFD solver to safety valves performances prediction

  16. Serotonin concentrations in platelets, plasma, mitral valve leaflet, and left ventricular myocardial tissue in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Cremer, Signe Emilie; Singletary, G.E.; Olsen, Lisbeth Høier

    2014-01-01

    HYPOTHESIS/OBJECTIVES: Altered serotonin (5-hydroxytryptamine, 5HT) signaling is postulated in development and progression of canine myxomatous mitral valve disease (MMVD). Little is known regarding platelet, plasma, valvular, or myocardial 5HT concentration ([5HT]) in affected dogs. We quantifie...

  17. Biphasic 201thallium scintgraphy after dipyridamole in mitral valve diseases

    International Nuclear Information System (INIS)

    Schmoliner, R.; Dudczak, R.; Kronik, G.; Moesslacher, H.; Kletter, K.; Frischauf, H.

    1980-01-01

    The results of biphasic 201 thallium scintigraphy after dipyridamole i.v. could neither prove nor exclude the presence of small focal lesions in the myocardium of 17 patients with mitral valve diseases. The frequent finding of a decrease in activity in the anterolateral myocardium is probably due to a relative increase in activity in the region of the inferior wall with superimposed areas of the papillary muscle and right ventricular myocardium. If the right ventricle is visualized in stress- or redistribution images, an increase in mean pulmonary artery pressure can be accepted. According to Cohen's criteria, a grade 2 or 3 virtually proves the existence of pulmonary hypertension, a grade 1 makes this finding rather probable. The possibility of pulmonary hypertension can not be excluded if the right ventricular myocardium is not visualized. (orig.) [de

  18. Surgical management of short bowel syndrome by construction of an isoperistaltic intestinal valve: an experimental study in dogs.

    Science.gov (United States)

    Papaziogas, T; Tassiopoulos, A; Papaziogas, B; Koutsias, S; Alexandrakis, A; Sakellaridis, D; Galanis, N

    1999-08-01

    To develop of an isoperistaltic invaginated valve for the treatment of short bowel syndrome. Randomised experimental study University Hospital, Greece 8 mongrel dogs 90% resection of the small bowel, followed by construction of an invaginated valve one month later. weight loss, fat excretion in the faeces, radiographic and histological examination of the valve, pressure curve along the valve. Weight loss and steatorrhoea were reversed over a period of 2-3 months without evidence of intestinal obstruction in any of the animals. The construction of an isoperistaltic invaginated valve could be a solution to the management of the short gut syndrome.

  19. Experimental study and DEM simulation of granular flow through a new sphere discharge valve

    International Nuclear Information System (INIS)

    Zhang He; Li Tianjin; Huang Zhiyong; Gao Zhi; Qi Weiwei; Bo Hanliang

    2015-01-01

    Experiments and DEM simulation have been conducted to investigate the granular flow through a new type of sphere discharge valve. The new sphere discharge valve was based on the principle of angle of repose. The glass sphere was used in the granular discharge experiments. Experimental results showed that the relation between the averaging sphere discharge mass flow rate and the stroke of the sphere discharge valve were consisted of three zones, i.e. the idle stroke zone, linearly zone and orifice restriction zone. The Beverloo's law was suitable for the granular flow through multi-orifices in the orifice restriction zone. The variation of averaging sphere discharge mass flow rate with the stroke of the sphere discharge valve was described by Beverloo's law with the modification based on the stroke of the sphere discharge valve. DEM simulation results showed that the drained angle of repose during granular flow in the sphere storage vessel remained 23 degrees with different stroke of the sphere discharge valve. (authors)

  20. An in vitro experimental study of flow past aortic valve under varied pulsatile conditions

    Science.gov (United States)

    Zhang, Ruihang; Zhang, Yan

    2017-11-01

    Flow past aortic valve represents a complex fluid-structure interaction phenomenon that involves pulsatile, vortical, and turbulent conditions. The flow characteristics immediately downstream of the valve, such as the variation of pulsatile flow velocity, formation of vortices, distribution of shear stresses, are of particular interest to further elucidate the role of hemodynamics in various aortic diseases. However, the fluid dynamics of a realistic aortic valve is not fully understood. Particularly, it is unclear how the flow fields downstream of the aortic valve would change under varied pulsatile inlet boundary conditions. In this study, an in vitro experiment has been conducted to investigate the flow fields downstream of a silicone aortic valve model within a cardiovascular flow simulator. Phased-locked Particle Image Velocimetry measurements were performed to map the velocity fields and Reynolds normal and shear stresses at different phases in a cardiac cycle. Temporal variations of pressure across the valve model were measured using high frequency transducers. Results have been compared for different pulsatile inlet conditions, including varied frequencies (heart rates), magnitudes (stroke volumes), and cardiac contractile functions (shapes of waveforms).

  1. Coronary artery disease in patients undergoing valve replacement at a tertiary care cardiac centre

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Hasan, K.; Hashmani, S.

    2011-01-01

    To determine the prevalence of coronary artery disease in patients undergoing valve surgery at a tertiary care cardiac centre. The medical records of 144 consecutive patients who underwent mitral, aortic or dual (mitral and aortic) valve replacement surgery at the Tabba Heart Institute between January 2006 to December 2008 were retrospectively reviewed. All patients underwent coronary angiogram. Significant coronary artery disease (CAD) is defined as coronary stenosis of > 50%. There were 74 (51.4%) males and 70 (48.6%) females in the study. The mean age was 51.64 +- 11 years. Of all, 73 (50.7%) underwent mitral valve replacement, 47 (32.6%) had aortic and 24 (16.7%) had dual valve replacement. Out of 144 patients, 99 (68.8%) had 50% stenosis. In patients who had undergone mitral valve replacement (MVR), significant coronary disease was found in 32.9%, whereas in patients who had undergone aortic valve replacement (AVR) and dual valve replacement (DVR) the prevalence of coronary disease was 31.9% and 25% respectively. Our results suggest that the overall prevalence of coronary artery disease in patients undergoing valve surgery in our population is comparable with prevalence reported in international data. (author)

  2. Management of mitral regurgitation in Marfan syndrome: Outcomes of valve repair versus replacement and comparison with myxomatous mitral valve disease.

    Science.gov (United States)

    Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M

    2014-09-01

    The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  3. Transcatheter aortic value implantation with self-expandable nitinol valved stent: an experimental study in sheep

    International Nuclear Information System (INIS)

    Jiang Haibin; Huang Xinmiao; Bai Yuan

    2011-01-01

    Objective: to determine the feasibility and safety of transcatheter aortic valve implantation with domestic self-expandable nitinol valved stent in experimental sheep. Methods: A fresh pig pericardium was cross-linked with a 0.6% glutaraldehyde solution for 36 hours and then sutured on a nitinol self-expandable stent. Ten healthy sheep of (46.00±2.60) kg body weight were chosen for the study. Under general anesthesia, the device was delivered through catheter into the native aortic valve of the sheep via the femoral artery or abdominal aorta. The animals were followed up for three months. Results: Six devices were successfully delivered at the desired position in six sheep with no occurrence of complications. Angiographic and hemodynamic studies confirmed that the stents were fixed at correct position with competent valve function immediately and 90 days after the procedure. Technical failure or fatal complications occurred in the remaining four sheep. Conclusion: Implantation of a domestic nitinol self-expandable stent at the aortic valve position through a transcatheter approach is feasible in experimental sheep. (authors)

  4. Toll-Like Receptors, Inflammation, and Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Carmen García-Rodríguez

    2018-03-01

    Full Text Available Inflammation, the primary response of innate immunity, is essential to initiate the calcification process underlying calcific aortic valve disease (CAVD, the most prevalent valvulopathy in Western countries. The pathogenesis of CAVD is multifactorial and includes inflammation, hemodynamic factors, fibrosis, and active calcification. In the development of CAVD, both innate and adaptive immune responses are activated, and accumulating evidences show the central role of inflammation in the initiation and propagation phases of the disease, being the function of Toll-like receptors (TLR particularly relevant. These receptors act as sentinels of the innate immune system by recognizing pattern molecules from both pathogens and host-derived molecules released after tissue damage. TLR mediate inflammation via NF-κB routes within and beyond the immune system, and play a crucial role in the control of infection and the maintenance of tissue homeostasis. This review outlines the current notions about the association between TLR signaling and the ensuing development of inflammation and fibrocalcific remodeling in the pathogenesis of CAVD. Recent data provide new insights into the inflammatory and osteogenic responses underlying the disease and further support the hypothesis that inflammation plays a mechanistic role in the initiation and progression of CAVD. These findings make TLR signaling a potential target for therapeutic intervention in CAVD.

  5. Comparative Transcriptomic Profiling and Gene Expression for Myxomatous Mitral Valve Disease in the Dog and Human

    Directory of Open Access Journals (Sweden)

    Greg R. Markby

    2017-07-01

    Full Text Available Myxomatous mitral valve disease is the single most important mitral valve disease in both dogs and humans. In the case of the dog it is ubiquitous, such that all aged dogs will have some evidence of the disease, and for humans it is known as Barlow’s disease and affects up to 3% of the population, with an expected increase in prevalence as the population ages. Disease in the two species show many similarities and while both have the classic myxomatous degeneration only in humans is there extensive fibrosis. This dual pathology of the human disease markedly affects the valve transcriptome and the difference between the dog and human is dominated by changes in genes associated with fibrosis. This review will briefly examine the comparative valve pathology and then, in more detail, the transcriptomic profiling and gene expression reported so far for both species.

  6. Acupuncture in patients with valvular heart disease and prosthetic valves.

    Science.gov (United States)

    Stellon, Anthony

    2003-09-01

    Endocarditis has been reported in patients with valvular heart disease who have undergone acupuncture treatment, although most have been associated with the use of semi-permanent needles. This has led reviewers to suggest that acupuncture may not only be contraindicated in such patients but that prophylactic antibiotics should be given. This study investigated the use of acupuncture treatment in patients with proven valvular heart disease and observed whether endocarditis developed in such patients. All patients in a single-handed GP practice with proven valvular heart disease, including those with prosthetic valves, were identified over a ten-year period. Those who had undergone acupuncture treatment underwent a clinical examination and diagnostic tests, which focused on the signs, symptoms and laboratory criteria for the diagnosis of endocarditis and included a transthoracic echocardiogram. Autopsy findings were reviewed in any patient who died. Based on these clinical and laboratory data, using the modified Duke's criteria for the diagnosis of endocarditis, patients were identified as having definite or possible endocarditis, or the diagnosis was rejected. All patients underwent brief acupuncture with no skin disinfectant and no prophylactic antibiotics were given. Semi-permanent needles were avoided. Thirty-six patients with valvular heart disease underwent a total of 479 acupuncture treatments over a ten-year period. The median number of treatments was 9 (range 1-72), with a follow-up after treatment of 5.75 years (range 0.5-10 years). Definite endocarditis was not found in any patient, but two patients had possible endocarditis, eventually discounted by both negative blood cultures and echocardiography. In conclusion, brief acupuncture was safe in this small cohort of valvular heart disease patients and no case of endocarditis was detected over a ten-year period.

  7. Experimental investigation of the discharge valve dynamics in a reciprocating compressor for trans-critical CO2 refrigeration cycle

    International Nuclear Information System (INIS)

    Ma Yuan; He Zhilong; Peng Xueyuan; Xing Ziwen

    2012-01-01

    The self-acting valve has a significant influence on the efficiency and reliability of the reciprocating compressor. In the trans-critical CO 2 cycle, the large density and high pressure difference across the valve cause serious bending and impact stresses in the valve, offering great challenges for successful valve design. Experimental investigation of the valve dynamics is required in order to design a self-acting valve with a high efficiency and long life span for the trans-critical CO 2 compressor. A semi-hermetic reciprocating compressor was developed for application in CO 2 refrigeration, and a test system was incorporated into the compressor performance test rig, with a focus on investigating the dynamics of the discharge valves. With the experimental results, the movement of the valve was discussed in detail for the trans-critical CO 2 compressor, allowing for the study of the thermodynamic performance of the compressor. While varying design parameters such as pressure ratio, valve lift, spring stiffness and compressor speed, the movement of the discharge valve in the reciprocating CO 2 compressor was measured in order to investigate the major factors that influence the valve dynamics. The average valve speed increased from 0.71 m/s to 0.81 m/s as the discharge pressure changed from 7.8 MPa to 12 MPa. The experimental methods and results discussed in this paper could provide useful information for both valve testing and the optimization of their reliability in trans-critical CO 2 compressors.

  8. A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.

    Science.gov (United States)

    Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E

    2017-11-01

    This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Experimental and simulation flow rate analysis of the 3/2 directional pneumatic valve

    Directory of Open Access Journals (Sweden)

    Blasiak Slawomir

    2017-01-01

    Full Text Available The work includes a study on the comparative analysis of two test methods. The first method - numerical method, consists in determining the flow characteristics with the use of ANSYS CFX. A modeled poppet directional valve 3/2 3D CAD software – SolidWorks was used for this purpose. Based on the solid model that was developed, simulation studies of the air flow through the way valve in the software for computational fluid dynamics Ansys CFX were conducted. The second method - experimental, entailed conducting tests on a specially constructed test stand. The comparison of the test results obtained on the basis of both methods made it possible to determine the cross-correlation. High compatibility of the results confirms the usefulness of the numerical procedures. Thus, they might serve to determine the flow characteristics of directional valves as an alternative to a costly and time-consuming test stand.

  10. Experimental and simulation flow rate analysis of the 3/2 directional pneumatic valve

    Science.gov (United States)

    Blasiak, Slawomir; Takosoglu, Jakub E.; Laski, Pawel A.; Pietrala, Dawid S.; Zwierzchowski, Jaroslaw; Bracha, Gabriel; Nowakowski, Lukasz; Blasiak, Malgorzata

    The work includes a study on the comparative analysis of two test methods. The first method - numerical method, consists in determining the flow characteristics with the use of ANSYS CFX. A modeled poppet directional valve 3/2 3D CAD software - SolidWorks was used for this purpose. Based on the solid model that was developed, simulation studies of the air flow through the way valve in the software for computational fluid dynamics Ansys CFX were conducted. The second method - experimental, entailed conducting tests on a specially constructed test stand. The comparison of the test results obtained on the basis of both methods made it possible to determine the cross-correlation. High compatibility of the results confirms the usefulness of the numerical procedures. Thus, they might serve to determine the flow characteristics of directional valves as an alternative to a costly and time-consuming test stand.

  11. Calcific Aortic Valve Disease Is Associated with Layer-Specific Alterations in Collagen Architecture.

    Directory of Open Access Journals (Sweden)

    Heather N Hutson

    Full Text Available Disorganization of the valve extracellular matrix (ECM is a hallmark of calcific aortic valve disease (CAVD. However, while microarchitectural features of the ECM can strongly influence the biological and mechanical behavior of tissues, little is known about the ECM microarchitecture in CAVD. In this work, we apply advanced imaging techniques to quantify spatially heterogeneous changes in collagen microarchitecture in CAVD. Human aortic valves were obtained from individuals between 50 and 75 years old with no evidence of valvular disease (healthy and individuals who underwent valve replacement surgery due to severe stenosis (diseased. Second Harmonic Generation microscopy and subsequent image quantification revealed layer-specific changes in fiber characteristics in healthy and diseased valves. Specifically, the majority of collagen fiber changes in CAVD were found to occur in the spongiosa, where collagen fiber number increased by over 2-fold, and fiber width and density also significantly increased. Relatively few fibrillar changes occurred in the fibrosa in CAVD, where fibers became significantly shorter, but did not otherwise change in terms of number, width, density, or alignment. Immunohistochemical staining for lysyl oxidase showed localized increased expression in the diseased fibrosa. These findings reveal a more complex picture of valvular collagen enrichment and arrangement in CAVD than has previously been described using traditional analysis methods. Changes in fiber architecture may play a role in regulating the pathobiological events and mechanical properties of valves during CAVD. Additionally, characterization of the ECM microarchitecture can inform the design of fibrous scaffolds for heart valve tissue engineering.

  12. Sliding spool design for reducing the actuation forces in direct operated proportional directional valves: Experimental validation

    International Nuclear Information System (INIS)

    Amirante, Riccardo; Distaso, Elia; Tamburrano, Paolo

    2016-01-01

    Highlights: • An innovative procedure to design a commercial proportional directional valve is shown. • Experimental tests are performed to demonstrate the flow force reduction. • The design is improved by means of a previously made optimization procedure. • Great reduction in the flow forces without reducing the flow rate is demonstrated. - Abstract: This paper presents the experimental validation of a new methodology for the design of the spool surfaces of four way three position direct operated proportional directional valves. The proposed methodology is based on the re-design of both the compensation profile (the central conical surface of the spool) and the lateral surfaces of the spool, in order to reduce the flow forces acting on the spool and hence the actuation forces. The aim of this work is to extend the application range of these valves to higher values of pressure and flow rate, thus avoiding the employment of more expensive two stage configurations in the case of high-pressure conditions and/or flow rate. The paper first presents a theoretical approach and a general strategy for the sliding spool design to be applied to any four way three position direct operated proportional directional valve. Then, the proposed approach is experimentally validated on a commercially available valve using a hydraulic circuit capable of measuring the flow rate as well as the actuation force over the entire spool stroke. The experimental results, performed using both the electronic driver provided by the manufacturer and a manual actuation system, show that the novel spool surface requires remarkably lower actuation forces compared to the commercial configuration, while maintaining the same flow rate trend as a function of the spool position.

  13. Vasovagal tonus index in dog with myxomatous mitral valve disease

    Directory of Open Access Journals (Sweden)

    Bruna C. Brüler

    Full Text Available ABSTRACT: The vasovagal tonus index (VVTI is a useful and assessable index, obtained from standard ECG recordings, that is used to estimate heart rate variability (HRV, and may provide valuable information regarding the likelihood of progression into congestive heart failure (CHF. In this paperwork, we investigated how the vasovagal tonus index (VVTI behaves in dogs with naturally-occurring myxomatous mitral valve disease (MMVD Electrocardiographic (ECG recordings and echocardiographic data of 120 patients diagnosed with MMVD were reviewed. The VVTI was calculated from twenty consecutive RR intervals for each dog enrolled in the study. Lower VVTI values were found in MMVD patients in American College of Veterinary Internal Medicine (ACVIM stage C compared with stages B1 and B2. Values were also lower in patients with severe cardiac remodeling. When a cut-off value of 6.66 is used, VVTI was able to discriminate MMVD patients in stage C from B1 and B2 dogs with a sensitivity of 70 per cent and a specificity of 77 per cent. MMVD dogs in which VVTI is lower than 6.66 are 30% more likely to develop congestive heart failure (CHF.

  14. Numerical analysis and experimental studies on solenoid common rail diesel injector with worn control valve

    Science.gov (United States)

    Krivtsov, S. N.; Yakimov, I. V.; Ozornin, S. P.

    2018-03-01

    A mathematical model of a solenoid common rail fuel injector was developed. Its difference from existing models is control valve wear simulation. A common rail injector of 0445110376 Series (Cummins ISf 2.8 Diesel engine) produced by Bosch Company was used as a research object. Injector parameters (fuel delivery and back leakage) were determined by calculation and experimental methods. GT-Suite model average R2 is 0.93 which means that it predicts the injection rate shape very accurately (nominal and marginal technical conditions of an injector). Numerical analysis and experimental studies showed that control valve wear increases back leakage and fuel delivery (especially at 160 MPa). The regression models for determining fuel delivery and back leakage effects on fuel pressure and energizing time were developed (for nominal and marginal technical conditions).

  15. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    Science.gov (United States)

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  16. Prosthetic valves in adult patients with congenital heart disease : Rationale and design of the Dutch PROSTAVA study

    NARCIS (Netherlands)

    Freling, H. G.; van Slooten, Y. J.; van Melle, J. P.; Mulder, B. J. M.; van Dijk, A. P. J.; Hillege, H. L.; Post, M. C.; Sieswerda, G. Tj; Jongbloed, M. R. M.; Willems, T. P.; Pieper, P. G.

    2012-01-01

    Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. The primary objective

  17. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  18. Clinical Implication of Aortic Wall Biopsy in Aortic Valve Disease with Bicuspid Valve Pathology

    Directory of Open Access Journals (Sweden)

    Yong Han Kim

    2016-12-01

    Full Text Available Background: Although unique aortic pathology related to bicuspid aortic valve (BAV has been previously reported, clinical implications of BAV to aortopathy risk have yet to be investigated. We looked for potential differences in matrix protein expressions in the aortic wall in BAV patients. Methods: Aorta specimens were obtained from 31 patients: BAV group (n=27, tricuspid aortic valve (TAV group (n=4. The BAV group was categorized into three subgroups: left coronary sinus-right coronary sinus (R+L group; n=13, 42%, right coronary sinus-non-coronary sinus (R+N group; n=8, 26%, and anteroposterior (AP group; n=6, 19%. We analyzed the expression of endothelial nitric oxide synthase (eNOS, matrix metalloproteinase (MMP-9, and tissue inhibitor of matrix metalloproteinase (TIMP-2. Results: Based on the mean value of the control group, BAV group showed decreased expression of eNOS in 72.7% of patients, increased MMP-9 in 82.3%, and decreased TIMP in 79.2%. There was a higher tendency for aortopathy in the BAV group: eNOS (BAV:TAV= 53%±7%:57%±11%, MMP-9 (BAV:TAV=48%±10%:38%±1%. The AP group showed lower expression of eNOS than the fusion (R+L, R+N group did; 48%±5% vs. 55%±7% (p=0.081. Conclusion: Not all patients with BAV had expression of aortopathy; however, for patients who had a suspicious form of bicuspid valve, aortic wall biopsy could be valuable to signify the presence of aortopathy.

  19. A DECISION SUPPORT SYSTEM FOR THE DIAGNOSIS OF HEART VALVE DISEASES

    OpenAIRE

    Türkoğlu, İbrahim; Arslan, Ahmet; İlkay, Erdoğan

    2018-01-01

    In this pa per, a decision s up port system is presented for interpretation of the Doppler signals of the heart valve diseases based on the pattern recognition. This paper especially deals with the feature extraction from measured Doppler signal waveforms at the heart valve using the Doppler Ultrasound. Wavelet transforms and power spectrum estimate by Yule-Walker AR method are used to feature extract from the Doppler signals on the time­frequency domain. Wavelet entropy method is applied to ...

  20. Experimental and Numerical Analysis of a Water Emptying Pipeline Using Different Air Valves

    Directory of Open Access Journals (Sweden)

    Oscar E. Coronado-Hernández

    2017-02-01

    Full Text Available The emptying procedure is a common operation that engineers have to face in pipelines. This generates subatmospheric pressure caused by the expansion of air pockets, which can produce the collapse of the system depending on the conditions of the installation. To avoid this problem, engineers have to install air valves in pipelines. However, if air valves are not adequately designed, then the risk in pipelines continues. In this research, a mathematical model is developed to simulate an emptying process in pipelines that can be used for planning this type of operation. The one-dimensional proposed model analyzes the water phase propagation by a new rigid model and the air pockets effect using thermodynamic formulations. The proposed model is validated through measurements of the air pocket absolute pressure, the water velocity and the length of the emptying columns in an experimental facility. Results show that the proposed model can accurately predict the hydraulic characteristic variables.

  1. High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods.

    Science.gov (United States)

    Toma, Milan; Bloodworth, Charles H; Einstein, Daniel R; Pierce, Eric L; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S

    2016-12-01

    The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography ([Formula: see text]CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for [Formula: see text]CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid-structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against [Formula: see text]CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.

  2. Rheumatic Heart Disease and Myxomatous Degeneration: Differences and Similarities of Valve Damage Resulting from Autoimmune Reactions and Matrix Disorganization.

    Science.gov (United States)

    Martins, Carlo de Oliveira; Demarchi, Lea; Ferreira, Frederico Moraes; Pomerantzeff, Pablo Maria Alberto; Brandao, Carlos; Sampaio, Roney Orismar; Spina, Guilherme Sobreira; Kalil, Jorge; Cunha-Neto, Edecio; Guilherme, Luiza

    2017-01-01

    Autoimmune inflammatory reactions leading to rheumatic fever (RF) and rheumatic heart disease (RHD) result from untreated Streptococcus pyogenes throat infections in individuals who exhibit genetic susceptibility. Immune effector mechanisms have been described that lead to heart tissue damage culminating in mitral and aortic valve dysfunctions. In myxomatous valve degeneration (MXD), the mitral valve is also damaged due to non-inflammatory mechanisms. Both diseases are characterized by structural valve disarray and a previous proteomic analysis of them has disclosed a distinct profile of matrix/structural proteins differentially expressed. Given their relevance in organizing valve tissue, we quantitatively evaluated the expression of vimentin, collagen VI, lumican, and vitronectin as well as performed immunohistochemical analysis of their distribution in valve tissue lesions of patients in both diseases. We identified abundant expression of two isoforms of vimentin (45 kDa, 42 kDa) with reduced expression of the full-size protein (54 kDa) in RHD valves. We also found increased vitronectin expression, reduced collagen VI expression and similar lumican expression between RHD and MXD valves. Immunohistochemical analysis indicated disrupted patterns of these proteins in myxomatous degeneration valves and disorganized distribution in rheumatic heart disease valves that correlated with clinical manifestations such as valve regurgitation or stenosis. Confocal microscopy analysis revealed a diverse pattern of distribution of collagen VI and lumican into RHD and MXD valves. Altogether, these results demonstrated distinct patterns of altered valve expression and tissue distribution/organization of structural/matrix proteins that play important pathophysiological roles in both valve diseases.

  3. Long-term tricuspid valve prosthesis-related complications in patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Freling, Hendrik G.; van Melle, Joost P.; Mulder, Barbara J. M.; Jongbloed, Monique R. M.; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2014-01-01

    In patients with acquired valvar disease, morbidity and mortality rates after tricuspid valve replacement (TVR) are high. However, in adult patients with congenital heart disease, though data concerning outcome after TVR are scarce, even poorer results are suggested in patients with Ebstein anomaly.

  4. Long-term tricuspid valve prosthesis-related complications in patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Freling, Hendrik G.; van Melle, Joost P.; Mulder, Barbara J. M.; Jongbloed, Monique R. M.; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    OBJECTIVES: In patients with acquired valvar disease, morbidity and mortality rates after tricuspid valve replacement (TVR) are high. However, in adult patients with congenital heart disease, though data concerning outcome after TVR are scarce, even poorer results are suggested in patients with

  5. Imaging of Mitral Valve Prolapse: What Can We Learn from Imaging about the Mechanism of the Disease?

    Directory of Open Access Journals (Sweden)

    Ronen Durst

    2015-07-01

    Full Text Available Mitral valve prolapse (MVP is the most common mitral valve disorder affecting 2%–3% of the general population. Two histological forms for the disease exist: Myxomatous degeneration and fibroelastic disease. Pathological evidence suggests the disease is not confined solely to the valve tissue, and accumulation of proteoglycans and fibrotic tissue can be seen in the adjacent myocardium of MVP patients. MVP is diagnosed by demonstrating valve tissue passing the annular line into the left atrium during systole. In this review we will discuss the advantages and limitations of various imaging modalities in their MVP diagnosis ability as well as the potential for demonstrating extra associated valvular pathologies.

  6. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  7. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    Directory of Open Access Journals (Sweden)

    Mustafa Zakkar

    2018-03-01

    Full Text Available Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  8. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    Science.gov (United States)

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  9. Rheumatic heart disease- a study of surgically excised cardiac valves and biopsies

    International Nuclear Information System (INIS)

    Khalil Ullah; Badsha, S.; Khan, A.; Kiani, M.R.; Ahmed, S.A.

    2002-01-01

    Objective: To examine the prevalence, age, sex and topographical distribution of the rheumatic heart diseases and its morphology. Design: A cross sectional descriptive study. Place and Duration of Study: Pathology Department, Army Medical College, Rawalpindi between 1981-1990. Patients and Methods: Five hundred and twenty six surgically excised cardiac valves and biopsies were studied in the laboratory in the light of clinical data. Results: Carditis constituted 87.4 % of the cardiac valvular disease with 23.5% active and 71% healed rheumatic lesions. About 5.5% had morphological appearances consistent with RHD. The lesions affected mitral valves (37.0%), aortic valve (22.1%), mitral and aortic valves together (21.0%) and atrial appendages (19.0%). Presentation was mostly as mitral stenosis either isolated (49.2% ) or combined (31.0%), aortic stenosis (11.7% ) and aortic incompetence with regurgitation (7.3%). Conclusion: Rheumatic carditis constitutes a significant proportion of cardiac valvular disease and affects comparatively younger age, with slight male preponderance and primarily affects mitral valve. (author)

  10. Association of altered collagen content and lysyl oxidase expression in degenerative mitral valve disease.

    Science.gov (United States)

    Purushothaman, K-Raman; Purushothaman, Meerarani; Turnbull, Irene C; Adams, David H; Anyanwu, Anelechi; Krishnan, Prakash; Kini, Annapoorna; Sharma, Samin K; O'Connor, William N; Moreno, Pedro R

    Collagen cross-linking is mediated by lysyl oxidase (LOX) enzyme in the extracellular matrix (ECM) of mitral valve leaflets. Alterations in collagen content and LOX protein expression in the ECM of degenerative mitral valve may enhance leaflet expansion and disease severity. Twenty posterior degenerative mitral valve leaflets from patients with severe mitral regurgitation were obtained at surgery. Five normal posterior mitral valve leaflets procured during autopsy served as controls. Valvular interstitial cells (VICs) density was quantified by immunohistochemistry, collagen Types I and III by picro-sirius red staining and immunohistochemistry, and proteoglycans by alcian blue staining. Protein expression of LOX and its mediator TGFβ1 were quantified by immunofluorescence and gene expression by PCR. VIC density was increased, structural Type I collagen density was reduced, while reparative Type III collagen and proteoglycan densities were increased (PDegenerative Mitral Valve Disease may be secondary to alterations in LOX protein expression, contributing to disorganization of ECM and disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Experimental Chagas' disease in dogs

    Directory of Open Access Journals (Sweden)

    Marta de Lana

    1992-03-01

    Full Text Available This paper describes the development of experimental Chagas' disease in 64 out-bred young dogs. Twenty-nine animals were inoculated with the Be-62 and 35 with Be-78 Trypanosoma cruzi strains. Twenty-six were infected with blood trypomastigotes by different inoculation routes and 38 with metacyclic trypomastigotes from the vector via the conjunctival route. Twenty of the 26 dogs infected with blood trypomastigotes were autopsied during the acute phase. Eleven died spontaneously and nine were sacrificed. Six remained alive until they died suddenly (two or were autopsied (four. Twelve of the 38 dogs infected with metacyclic trypomastigotes evolved naturally to the chronic phase and remained alive for 24-48 months. The parasitemia, clinical aspects and serology (IgM and IgG as well as electrocardiogram, hemogram and heart anatomo-histopathologic patterns of acute and chronic cardiac forms of Chagas' disease as seen in human infections, were reproduced. The most important finding is the reproductibility of diffuse fibrosing chronic chagasic cardiopathy in all dogs infected with Be-78 T. cruzi strain autopsied between the 90th and 864th days of infection. Thus, the dog can be considered as a suitable experimental model to study Chagas' disease according to the requisites of the World Health Organization (1984. Futhermore the animal is easily obtained and easy to handle and maintain in experimental laboratory conditions.

  12. Experimental investigations on the fluid-mechanics of an electrospun heart valve by means of particle image velocimetry.

    Science.gov (United States)

    Del Gaudio, Costantino; Gasbarroni, Pier Luca; Romano, Giovanni Paolo

    2016-12-01

    End-stage failing heart valves are currently replaced by mechanical or biological prostheses. Both types positively contribute to restore the physiological function of native valves, but a number of drawbacks limits the expected performances. In order to improve the outcome, tissue engineering can offer an alternative approach to design and fabricate innovative heart valves capable to support the requested function and to promote the formation of a novel, viable and correctly operating physiological structure. This potential result is particularly critical if referred to the aortic valve, being the one mainly exposed to structural and functional degeneration. In this regard, the here proposed study presents the fabrication and in vitro characterization of a bioresorbable electrospun heart valve prosthesis using the particle image velocimetry technique either in physiological and pathological fluid dynamic conditions. The scaffold was designed to reproduce the aortic valve geometry, also mimicking the fibrous structure of the natural extracellular matrix. To evaluate its performances for possible implantation, the flow fields downstream the valve were accurately investigated and compared. The experimental results showed a correct functionality of the device, supported by the formation of vortex structures at the edge of the three cusps, with Reynolds stress values below the threshold for the risk of hemolysis (which can be comprised in the range 400-4000N/m(2) depending on the exposure period), and a good structural resistance to the mechanical loads generated by the driving pressure difference. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The value of MRI in the diagnosis of heart valve diseases

    International Nuclear Information System (INIS)

    Zhao Shihua; Lu Minjie; Zhang Yan; Jiang Shiliang; Liu Yuqing; Zhang Puhong

    2006-01-01

    Objective: To assess the diagnostic value of the magnetic resonance imaging (MRI) for heart valve disease qualitatively and quantitatively. Methods: From 18th Sep, 2004 to 30th Jun, 2005, 56 consecutive patients underwent MR scanning with multiple sequences, including two-dimensional dark and bright sequences, K-space segmented TrueFISP and FLASH cine sequences, as well as velocity-encoded cine MR(VEC-MR). Morphologic and functional parameters were applied to assess the disease qualitatively and quantitatively. For quantitative analysis, Doppler echocardiography was compared to evaluate the reliability of VEC-MR in assessing the severity of aortic valve disease. Correlations coefficient was analyzed by a statistic software (SPSS 13.0), P sq =0.951, P=0.01 for AS and R=0.965, R sq =0.932, P<0.01 for AI). Conclusion: Heart valve diseases can be qualitatively and quantitatively evaluated by MR multiple sequences, especially in aortic valve disease. (authors)

  14. Interaction of renal failure and dyslipidaemia in the development of calcific aortic valve disease in rats.

    Science.gov (United States)

    Gillis, Kris; Roosens, Bram; Bala, Gezim; Remory, Isabel; Hernot, Sophie; Delvenne, Philippe; Mestrez, Fabienne; Droogmans, Steven; Cosyns, Bernard

    2017-10-01

    Calcific aortic valve disease (CAVD) is currently the most common heart valve disease worldwide and is known to be an active process. Both renal failure and dyslipidaemia are considered to be promoting factors for the development of valvular calcifications. The aim of this study is to prospectively evaluate the respective contribution and interaction of renal failure and dyslipidaemia on CAVD in a rat model, using echocardiography and compared with histology. Sixty-eight male Wistar rats were prospectively divided in eight groups, each fed a different diet to induce renal failure alone and combined with hyperlipidaemia or hypercholesterolemia. CAVD was detected and quantified by calibrated integrated backscatter of ultrasound (cIB) and compared with the histological calcium score. The study follow-up was 20 weeks. At the end of the study, the cIB value and the calcium score of the aortic valve were significantly increased in the group with isolated renal failure but not with dyslipidaemia. The combination of renal failure with high cholesterol or high-fat diet did not significantly increase calcifications further. Renal failure alone does induce aortic valve calcifications in a rat model of CAVD, whereas dyslipidaemia alone does not. The combination of renal failure with dyslipidaemia does not increase calcification further. These findings suggest that a combination of atherosclerotic and calcifying factors is not required to induce aortic valve calcifications in this model.

  15. Von Willebrand Factor as a Novel Player in Valvular Heart Disease: From Bench to Valve Replacement.

    Science.gov (United States)

    Gragnano, Felice; Crisci, Mario; Bigazzi, Maurizio Cappelli; Bianchi, Renatomaria; Sperlongano, Simona; Natale, Francesco; Fimiani, Fabio; Concilio, Claudia; Cesaro, Arturo; Pariggiano, Ivana; Diana, Vincenzo; Limongelli, Giuseppe; Cirillo, Plinio; Russo, Mariagiovanna; Golia, Enrica; Calabrò, Paolo

    2018-02-01

    von Willebrand Factor (vWF) is a well-known mediator of hemostasis and vascular inflammation. Its dynamic modulation in the bloodstream, according to hemodynamic conditions, makes it an appealing biomarker in patients with valvular heart disease (VHD). Recent studies highlight the close connection between vWF and VHD, with possible implications in the pathogenesis of VHD, promoting valve aging and calcification or favoring the development of infective endocarditis. Moreover, vWF has been recently proposed as a new diagnostic and prognostic tool in patients with valve stenosis or regurgitation, showing a strict correlation with severity of valve disease, outcome, and bleeding (Heyde syndrome). A novel role for vWF is also emerging in patients undergoing percutaneous or surgical valve repair/replacement to select and stratify patients, evaluate periprocedural bleeding risk, and detect procedural complications. We also report our single-center experience, suggesting, for the first time, possible clinical implications for vWF in percutaneous mitral valve repair (MitraClip). This review summarizes recent advances in the role of vWF in VHD with an updated overview going from bench to operating room.

  16. Experimental Assessment of Flow Fields Associated with Heart Valve Prostheses Using Particle Image Velocimetry (PIV): Recommendations for Best Practices.

    Science.gov (United States)

    Raghav, Vrishank; Sastry, Sudeep; Saikrishnan, Neelakantan

    2018-03-12

    Experimental flow field characterization is a critical component of the assessment of the hemolytic and thrombogenic potential of heart valve substitutes, thus it is important to identify best practices for these experimental techniques. This paper presents a brief review of commonly used flow assessment techniques such as Particle image velocimetry (PIV), Laser doppler velocimetry, and Phase contrast magnetic resonance imaging and a comparison of these methodologies. In particular, recommendations for setting up planar PIV experiments such as recommended imaging instrumentation, acquisition and data processing are discussed in the context of heart valve flows. Multiple metrics such as residence time, local velocity and shear stress that have been identified in the literature as being relevant to hemolysis and thrombosis in heart valves are discussed. Additionally, a framework for uncertainty analysis and data reporting for PIV studies of heart valves is presented in this paper. It is anticipated that this paper will provide useful information for heart valve device manufacturers and researchers to assess heart valve flow fields for the potential for hemolysis and thrombosis.

  17. Cardiac Hemodynamics in the Pathogenesis of Congenital Heart Disease and Aortic Valve Calcification

    Science.gov (United States)

    Nigam, Vishal

    2011-11-01

    An improved understanding of the roles of hemodynamic forces play in cardiac development and the pathogenesis of cardiac disease will have significant scientific and clinical impact. I will focus on the role of fluid dynamics in congenital heart disease and aortic valve calcification. Congenital heart defects are the most common form of birth defect. Aortic valve calcification/stenosis is the third leading cause of adult heart disease and the most common form of acquired valvular disease in developed countries. Given the high incidence of these diseases and their associated morbidity and mortality, the potential translational impact of an improved understanding of cardiac hemodynamic forces is very large. Division of Pediatric Cardiology, Rady Children's Hospital, San Diego

  18. Experimental and Computational Study of Two-phase (Air–Palm Oil Flow through Pipe and Control Valve in Series

    Directory of Open Access Journals (Sweden)

    Arivazhagan M.

    2009-03-01

    Full Text Available The contact of two or more immiscible liquids is encountered widely in the chemical and petroleum industries. Studies on operating characteristics of control valves with two phase flow have not been given much attention in the literature despite its industrial importance during design and selection as well as plant operations .The present work attempts to study experimentally the effect of two phase flow on pressure drop across pipe and control valve in series and compare with simulated results. Two-phase computational fluid dynamics (CFD calculations, using commercial CFD package FLUENT 6.2.16, were employed to calculate the simulated the pressure drop in Air–Palm oil flow in pipes and control valves. The Air flow rate varied from 25 to100 l/h flow rate. For constant valve position and Air flow rate, the Palm oil flow rate was varied from 50 to 150 l/h. The numerical results were validated against experimental data. The prediction of the pressure drop characteristics in pipe and valve were within an average error of about ± 3 %. A comparison of experimental and computed profiles was found to be in good agreement.

  19. Experimental Validation of Modelled Fluid Forces in Fast Switching Hydraulic On/Off Valves

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck

    2015-01-01

    A prototype of a fast switching valve for a digital hydraulic machine has been designed and manufactured. The valve is composed of an annular seat plunger connected with a moving coil actuator as the force producing element. The valve prototype is designed for flow rates of 600 l/min with less th...

  20. Validation of a numerical 3-D fluid-structure interaction model for a prosthetic valve based on experimental PIV measurements.

    Science.gov (United States)

    Guivier-Curien, Carine; Deplano, Valérie; Bertrand, Eric

    2009-10-01

    A numerical 3-D fluid-structure interaction (FSI) model of a prosthetic aortic valve was developed, based on a commercial computational fluid dynamics (CFD) software program using an Arbitrary Eulerian Lagrangian (ALE) formulation. To make sure of the validity of this numerical model, an equivalent experimental model accounting for both the geometrical features and the hydrodynamic conditions was also developed. The leaflet and the flow behaviours around the bileaflet valve were investigated numerically and experimentally by performing particle image velocimetry (PIV) measurements. Through quantitative and qualitative comparisons, it was shown that the leaflet behaviour and the velocity fields were similar in both models. The present study allows the validation of a fully coupled 3-D FSI numerical model. The promising numerical tool could be therefore used to investigate clinical issues involving the aortic valve.

  1. Echocardiographic Evaluation of Hemodynamic Changes in Left-Sided Heart Valves in Pregnant Women With Valvular Heart Disease.

    Science.gov (United States)

    Samiei, Niloufar; Amirsardari, Mandana; Rezaei, Yousef; Parsaee, Mozhgan; Kashfi, Fahimeh; Hantoosh Zadeh, Sedigheh; Beikmohamadi, Somayeh; Fouladi, Masoumeh; Hosseini, Saeid; Peighambari, Mohammad Mehdi; Mohebbi, Ahmad

    2016-10-01

    Physiologic changes during pregnancy can deteriorate or improve patients' hemodynamic status in the setting of valvular heart disease. There are sparse data regarding the effect of pregnancy on valve hemodynamics in normal pregnant women with known valvular heart disease. In a prospective study from July 2014 to January 2016, a total of 52 normal pregnant women who had mitral stenosis, aortic stenosis, or a history of mitral valve or aortic valve replacements were assessed. All patients underwent echocardiographic examinations and hemodynamic parameters were measured for both the mitral valve and aortic valve at first, second, and third trimesters. The parameters included mean gradient, peak gradient, mean gradient/heart rate, peak gradient/heart rate, pressure halftime, dimensionless velocity index, and valve area. Although most hemodynamic parameters (i.e., mean gradient, peak gradient, mean gradient/heart rate, and peak gradient/heart rate) increased approximately 50% from first to second trimester and first to third trimester (p 0.05). The ratio of changes between trimesters for valve area and dimensionless velocity index were comparable. No clinical decompensations were observed except for 3 and 7 cases of deterioration to functional class II at second and third trimesters, respectively. In conclusion, during a full-term and uncomplicated pregnancy, mitral and aortic valve gradients increase without significant changes in valve area that are more marked between the second and first trimester than between the third and second trimester. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Pars plana Ahmed valve and vitrectomy in patients with glaucoma associated with posterior segment disease.

    Science.gov (United States)

    Wallsh, Josh O; Gallemore, Ron P; Taban, Mehran; Hu, Charles; Sharareh, Behnam

    2013-01-01

    To assess the safety and efficacy of a modified technique for pars plana placement of the Ahmed valve in combination with pars plana vitrectomy in the treatment of glaucoma associated with posterior segment disease. Thirty-nine eyes with glaucoma associated with posterior segment disease underwent pars plana vitrectomy combined with Ahmed valve placement. All valves were placed in the pars plana using a modified technique, without the pars plana clip, and using a scleral patch graft. The 24 eyes diagnosed with neovascular glaucoma had an improvement in intraocular pressure from 37.6 mmHg to 13.8 mmHg and best-corrected visual acuity from 2.13 logarithm of minimum angle of resolution to 1.40 logarithm of minimum angle of resolution. Fifteen eyes diagnosed with steroid-induced glaucoma had an improvement in intraocular pressure from 27.9 mmHg to 14.1 mmHg and best-corrected visual acuity from 1.38 logarithm of minimum angle of resolution to 1.13 logarithm of minimum angle of resolution. Complications included four cases of cystic bleb formation and one case of choroidal detachment and explantation for hypotony. Ahmed valve placement through the pars plana during vitrectomy is an effective option for managing complex cases of glaucoma without the use of the pars plana clip.

  3. Cellular Changes during Renal Failure-Induced Inflammatory Aortic Valve Disease.

    Directory of Open Access Journals (Sweden)

    Mony Shuvy

    Full Text Available Aortic valve calcification (AVC secondary to renal failure (RF is an inflammation-regulated process, but its pathogenesis remains unknown. We sought to assess the cellular processes that are involved in the early phases of aortic valve disease using a unique animal model of RF-associated AVC.Aortic valves were obtained from rats that were fed a uremia-inducing diet exclusively for 2, 3, 4, 5, and 6 weeks as well as from controls. Pathological examination of the valves included histological characterization, von Kossa staining, and antigen expression analyses.After 2 weeks, we noted a significant increase in urea and creatinine levels, reflecting RF. RF parameters exacerbated until the Week 5 and plateaued. Whereas no histological changes or calcification was observed in the valves of any study group, macrophage accumulation became apparent as early as 2 weeks after the diet was started and rose after 3 weeks. By western blot, osteoblast markers were expressed after 2 weeks on the diet and decreased after 6 weeks. Collagen 3 was up-regulated after 3 weeks, plateauing at 4 weeks, whereas collagen 1 levels peaked at 2 and 4 weeks. Fibronectin levels increased gradually until Week 5 and decreased at 6 weeks. We observed early activation of the ERK pathway, whereas other pathways remained unchanged.We concluded that RF induces dramatic changes at the cellular level, including macrophage accumulation, activation of cell signaling pathway and extracellular matrix modification. These changes precede valve calcification and may increase propensity for calcification, and have to be investigated further.

  4. Heart Rate Variability in Cavalier King Charles Spaniels with Different Degree of Myxomatous Mitral Valve Disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2010-01-01

    Sciences, University of Copenhagen, Frederiksberg, Denmark, 2Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden; and 3Novo Nordic A/S, Maaloev, Denmark. Introduction: Modulation of heart rate by the autonomic nervous system can indirectly be measured by heart rate...... variability (HRV). Reduced HRV is seen in dogs with heart failure secondary to myxomatous mitral valve disease (MMVD). However, HRV is suggested to increase with disease progression in dogs with early stages of MMVD. Comparable results are found in people with primary mitral valve prolapse, a disease...... resembling canine MMVD. Aim: To associate progression of MMVD in dogs with time and frequency domain HRV, analysed from 24-hour electrocardiography. Materials and Methods: Eighty-one Cavalier King Charles Spaniels (CKCS) were examined by echocardiography and 24-hour electrocardiography. CKCS were divided...

  5. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  6. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  7. Double Valve Replacement (Mitral and Aortic for Rheumatic Heart Disease: A 20-year experience with 300 patients.

    Directory of Open Access Journals (Sweden)

    Prashant Mishra

    2016-09-01

    Full Text Available Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic in patients of rheumatic heart disease. Materials and Methods: Between 1988 and 2008, 300 patients of rheumatic heart disease underwent double (Mitral and Aortic valve replacement with Starr Edwards valve or St Jude mechanical valve prosthesis were implanted. These patients were studied retrospectively for preoperative data and postoperative outcome including causes of early and late deaths and the data was analyzed statistically. Results: The 30-day hospital death rate was 11.3% andlate death occurred in 11.6%. Anticoagulant regimen was followed to maintain the target pro-thrombin time at 1.5 times the control value. The actuarial survival (exclusive of hospital mortality was 92.4%, 84.6%, and 84.4%, per year at 5, 10, and 20 years, respectively Conclusions: In view of the acknowledged advantageof superior durability, increased thromboresistance in our patient population, and its cost effectiveness the Starr-Edwards ball valve or St. Jude valve is the mechanical prosthesis of choice for advanced combined valvular disease. The low-intensity anticoagulant regimen has offered suffcient protection against thromboembolism as well as hemorrhage.

  8. [Cox/maze III procedure combined with mitral valve replacement in treatment of rheumatic mitral valve disease with atrial fibrilation].

    Science.gov (United States)

    Chen, Rukun; Wang, Yongqing; Chen, Yongbing; Chen, Suocheng

    2002-06-25

    To compare the curative effect of Cox/maze III procedure combined with mitral replacement and that of mitral valve replacement (MVR). Fifty-six patients suffering from rheumatic heart disease with atrial fibrillation (AF) were treated by Cox/maze III procedure combined with MVR (maze group). Another 56 age, sex, and heart function-matched patients with the same diagnosis underwent MVR alone during the same period. Warfarin was administered after operation in both groups. Comparison of operative complication and curative effects was made. The aortic cross-clamp time and cardio pulmonary bypass time (CPB) were longer in maze group than in MVT group (75 +/- 22 min vs 41 +/- 11 min, P Atrial contractility was restored in all patients with sinus rhythm. One year after operation, 98.18% patients' cardiac function changed to grade and 1.82% changed to grade II. In MVR group AF disappeared after operation temporarily for 24 hours in 7 patients and re-appeared, and AF disappeared in one patients for 2 years so far. One year after operation, the cardiac function of 94.6% patients in MVR group changed to grade I, of 3.6% patients to grade II, and of 1.8% patients to grade III. No serious hemorrhage relate d to anticoagulant therapy happened. One patient in MVR group suffered from hemiplegia due to cerebral embolism. The late mortality was 1.8% on maze group amd 3.6% in MVR group. Cox/maze III procedure combined with NVR is safe and effective in treating rheumatic heart disease with AF.

  9. Modeling and experimental study of residual stresses in NOREM hardfacing coatings used in valve parts

    International Nuclear Information System (INIS)

    Beaurin, G.

    2012-01-01

    Hardfacing coatings are widely used on the surfaces of parts subjected to drastic loadings. Norem02 alloy, Fe-based, is used in PWR nuclear power plants on valves seating surfaces. Its microstructure consists of a dendritic austenite structure with ferrite islets and carbides. This work tends to demonstrate that for this alloy, metallurgical evolution during the welding process has very little influence on mechanical properties. Tensile behavior was characterized and completed by dilatometry tests in welding process temperature range until 1000 Celsius degrees, in order to identify an elastoplastic model with non linear kinematic hardening rule. Temperature, displacements, distortions and residual stresses were measured during the PTAW (Plasma Transferred Arc Welding) process and used to identify an equivalent thermal loading by solving an inverse problem. Finally, the numerical simulation of the whole process using the EDF FEM software Code-Aster is presented. Predicted temperatures are consistent with experimental ones. In the same way, predicted displacements, residual distortions and residual stresses at the end of the cooling phase are close to experimental measures, validating the modeling strategy presented in this work. (author)

  10. Autoimmune Disease with Cardiac Valves Involvement: Libman-Sacks Endocarditis.

    Science.gov (United States)

    Ginanjar, Eka; Yulianto, Yulianto

    2017-04-01

    This case study aim to evaluate the response of steroid treatment for autoimmune endocarditis. Valvular heart disease is relatively rising in both congenital and acquired cases, but the autoimmune endocarditis remains rare. In this case, a 34 year old woman with clinical manifestation resembling systemic lupus erythematosus (SLE) is diagnosed with Libman-sacks Endocarditis. After six months of steroid treatment, her clinical manifestations and heart structure improved.

  11. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    Science.gov (United States)

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Experimental Study on Fracture Failure of BRW 250 Pump Liquid Valve Mechanical Spring Surface

    Directory of Open Access Journals (Sweden)

    Rui Zeng

    2017-01-01

    Full Text Available In this paper, the singularity analysis method based on the continuous wave for the vibration signal of the plunger pump liquid valve under different conditions was studied, and the LMS based weighted least square method with good robustness and validity was proposed to calculate the LPZ index, which was the judgment criterion for fault of liquid valve mechanical spring. Fault diagnostic test results showed that the method could overcome the singularity of the binary discrete wave in the detection and quantitative accuracy problem, realize the accurate positioning of the singular point in the signal, identify the liquid valve disc in the spring break state to the liquid valve seat or lift limit the impact of the moment, and determine the fault of the liquid valve mechanical spring effectively.

  13. Does concomitant tricuspid annuloplasty increase perioperative mortality and morbidity when correcting left-sided valve disease?

    Science.gov (United States)

    Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu

    2015-01-01

    A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences

  14. Predictive value of natriuretic peptides in dogs with mitral valve disease

    DEFF Research Database (Denmark)

    Tarnow, Inge; Olsen, Lisbeth Høier; Kvart, Clarence

    2009-01-01

    Natriuretic peptides are useful in diagnosing heart failure in dogs. However, their usefulness in detecting early stages of myxomatous mitral valve disease (MMVD) has been debated. This study evaluated N-terminal (NT) fragment pro-atrial natriuretic peptide (NT-proANP) and NT-pro-brain natriuretic...... peptide (NT-proBNP) in 39 Cavalier King Charles Spaniels (CKCS) with pre-clinical mitral valve regurgitation (MR), sixteen dogs with clinical signs of heart failure (HF) and thirteen healthy control dogs. Twenty seven CKCS and ten control dogs were re-examined 4 years after the initial examination...... and the status of the dogs 5 years after the initial examination was determined by telephone calls to the owner. All dogs were evaluated by clinical examination and echocardiography. CKCS with severe MR had higher NT-proANP and NT-proBNP compared to controls and CKCS with less severe MR. Dogs with clinical signs...

  15. Comprehensive microRNA profiling reveals potential augmentation of the IL1 pathway in rheumatic heart valve disease.

    Science.gov (United States)

    Lu, Qiyu; Sun, Yi; Duan, Yuyin; Li, Bin; Xia, Jianming; Yu, Songhua; Zhang, Guimin

    2018-03-16

    Valvular heart disease is a leading cause of cardiovascular mortality, especially in China. More than a half of valvular heart diseases are caused by acute rheumatic fever. microRNA is involved in many physiological and pathological processes. However, the miRNA profile of the rheumatic valvular heart disease is unknown. This research is to discuss microRNAs and their target gene pathways involved in rheumatic heart valve disease. Serum miRNA from one healthy individual and four rheumatic heart disease patients were sequenced. Specific differentially expressed miRNAs were quantified by Q-PCR in 40 patients, with 20 low-to-moderate rheumatic mitral valve stenosis patients and 20 severe mitral valve stenosis patients. The target relationship between certain miRNA and predicted target genes were analysis by Luciferase reporter assay. The IL-1β and IL1R1 expression levels were analyzed by immunohistochemistry and western blot in the mitral valve from surgery of mitral valve replacement. The results showed that 13 and 91 miRNAs were commonly upregulated or downregulated in all four patients. Nine miRNAs, 1 upregulated and 8 downregulated, that had a similar fold change in all 4 patients were selected for quantitative PCR verification. The results showed similar results from miRNA sequencing. Within these 9 tested miRNAs, hsa-miR-205-3p and hsa-miR-3909 showed a low degree of dispersion between the members of each group. Hsa miR-205-3p and hsa-miR-3909 were predicted to target the 3'UTR of IL-1β and IL1R1 respectively. This was verified by luciferase reporter assays. Immunohistochemistry and Western blot results showed that the mitral valve from rheumatic valve heart disease showed higher levels of IL- 1β and IL1R1 expression compared with congenital heart valve disease. This suggested a difference between rheumatic heart valve disease and other types of heart valve diseases, with more inflammatory responses in the former. In the present study, by next generation

  16. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease.

    Science.gov (United States)

    van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (pHeart Association (NYHA) class remained stable in most patients. PPM showed no significant effect on death or hospitalisation during follow-up (p=0.218). In this study we report a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Experimental study on coil of direct action solenoid valve with temperature increasing

    International Nuclear Information System (INIS)

    Wang Lu; Liu Qianfeng; Bo Hanliang

    2012-01-01

    Hydraulic control rod drive technology (HCRDT) is a newly invented patent and Institute of Nuclear and New Energy Technology of Tsinghua University owns HCRDT's independent intellectual property rights. The integrated valve which is made up of three direct action solenoid valves is the key part of this technology, so the performance of the solenoid valve directly affects the function of the integrated valve and the HCRDT. Based on the conditions occurring in the operation of the control rod hydraulic drive system, the coil of the direct action solenoid valve with temperature increasing was studied by the experiment and analyzed by ANSYS code. The result shows that the temperature of the coil for the solenoid valve increases with the current increasing firstly. The temperature of the inner wall of the coil is higher than that of the exterior wall. The temperature of the middle coil is higher than that of the edge of the coil. The design of the direct action solenoid valve can be optimized. (authors)

  18. Oxidized Phospholipids and Risk of Calcific Aortic Valve Disease

    DEFF Research Database (Denmark)

    Kamstrup, Pia R.; Hung, Ming Yow; Witztum, Joseph L.

    2017-01-01

    -control study was performed within the Copenhagen General Population Study (n=87 980), including 725 CAVD cases (1977-2013) and 1413 controls free of cardiovascular disease. OxPL carried by apoB (apolipoprotein B-100; OxPL-apoB) or apolipoprotein(a) (OxPL-apo(a)) containing lipoproteins, lipoprotein(a) levels......, LPA kringle IV type 2 repeat, and rs10455872 genetic variants were measured. OxPL-apoB and OxPL-apo(a) levels correlated with lipoprotein(a) levels among cases (r=0.75 and r=0.95; both Plevels associated with risk of CAVD with odds.......001). Corresponding odds ratios for OxPL-apo(a) were 1.2 (95% CI, 1.0-1.5), 1.2(95% CI, 0.9-1.6), 2.1(95% CI, 1.4-3.1), and 2.9(95% CI, 1.9-4.5; trend, Pa) levels and explained 34%, 46%, and 39...

  19. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  20. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  1. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    Science.gov (United States)

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  2. Surgical RF ablation of atrial fibrillation in patients undergoing mitral valve repair for Barlow disease.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, G; Gelsomino, S; Carone, E; Gensini, G F; Stefàno, P L

    2013-01-01

    At present, limited experience exists on the treatment of atrial fibrillation (AF) in patients undergoing mitral valve repair (MVR) for Barlow disease. The aim of this investigation was to prospectively evaluate the radiofrequency ablation of AF in patients undergoing MVR for severe regurgitation due to Barlow disease. From January 1, 2007 to December 31, 2010, out of 85 consecutive patients with Barlow disease, 27 with AF underwent RF ablation associated with MVR. They were examined every 4 months in the first year after surgery and thereafter twice yearly. At follow-up, AF was observed in 4/25 (16.0%). NYHA (New York Heart Association) functional class improved significantly, with no patients in class III or IV (before surgery, 81.5% had been). Otherwise, among 58 patients in sinus rhythm, 6 (11%) developed AF during follow-up. No clinical or echocardiographic predictive factor was found in this subgroup. Results from our investigation suggest that radiofrequency ablation of AF in patients with Barlow disease undergoing MVR for severe regurgitation is effective and should be considered in every patient with Barlow disease and AF undergoing valve surgical repair. Copyright © 2013 S. Karger AG, Basel.

  3. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  4. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  5. Surgical Treatment of Atrial Fibrillation in Patients with Rheumatic Valve Disease

    Directory of Open Access Journals (Sweden)

    Ernesto Koehler Chavez

    Full Text Available Abstract Objective: To assess heart rhythm and predictive factors associated with sinus rhythm after one year in patients with rheumatic valve disease undergoing concomitant surgical treatment of atrial fibrillation. Operative mortality, survival and occurrence of stroke after one year were also evaluated. Methods: Retrospective longitudinal observational study of 103 patients undergoing rheumatic mitral valve surgery and ablation of atrial fibrillation using uni- or bipolar radiofrequency between January 2013 and December 2014. Age, gender, functional class (NYHA, type of atrial fibrillation, EuroSCORE, duration of atrial fibrillation, stroke, left atrial size, left ventricular ejection fraction, cardiopulmonary bypass time, myocardial ischemia time and type of radiofrequency were investigated. Results: After one year, 66.3% of patients were in sinus rhythm. Sinus rhythm at hospital discharge, lower left atrial size in the preoperative period and bipolar radiofrequency were associated with a greater chance of sinus rhythm after one year. Operative mortality was 7.7%. Survival rate after one year was 92.3% and occurrence of stroke was 1%. Conclusion: Atrial fibrillation ablation surgery with surgical approach of rheumatic mitral valve resulted in 63.1% patients in sinus rhythm after one year. Discharge from hospital in sinus rhythm was a predictor of maintenance of this rhythm. Increased left atrium and use of unipolar radiofrequency were associated with lower chance of sinus rhythm. Operative mortality rate of 7.7% and survival and stroke-free survival contribute to excellent care results for this approach.

  6. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Meurs, Kathryn M.; Olsen, Lisbeth H.; Reimann, Maria J.

    2018-01-01

    a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated......Objectives Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified...... with alterations in ACE activity at different stages of cardiac disease. Methods Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Results Forty-three dogs were homozygous for the ACE polymorphism...

  7. Association of Aortic Valve Sclerosis with Previous Coronary Artery Disease and Risk Factors

    Directory of Open Access Journals (Sweden)

    Filipe Carvalho Marmelo

    2014-11-01

    Full Text Available Background: Aortic valve sclerosis (AVS is characterized by increased thickness, calcification and stiffness of the aortic leaflets without fusion of the commissures. Several studies show an association between AVS and presence of coronary artery disease. Objective: The aim of this study is to investigate the association between presence of AVS with occurrence of previous coronary artery disease and classical risk factors. Methods: The sample was composed of 2,493 individuals who underwent transthoracic echocardiography between August 2011 and December 2012. The mean age of the cohort was 67.5 ± 15.9 years, and 50.7% were female. Results: The most frequent clinical indication for Doppler echocardiography was the presence of stroke (28.8%, and the most common risk factor was hypertension (60.8%. The most prevalent pathological findings on Doppler echocardiography were mitral valve sclerosis (37.1% and AVS (36.7%. There was a statistically significant association between AVS with hypertension (p < 0.001, myocardial infarction (p = 0.007, diabetes (p = 0.006 and compromised left ventricular systolic function (p < 0.001. Conclusion: Patients with AVS have higher prevalences of hypertension, stroke, hypercholesterolemia, myocardial infarction, diabetes and compromised left ventricular systolic function when compared with patients without AVS. We conclude that there is an association between presence of AVS with previous coronary artery disease and classical risk factors.

  8. Experimental and Potential Analysis of a Single-Valve Expander for Waste Heat Recovery of a Gasoline Engine

    Directory of Open Access Journals (Sweden)

    Wenzhi Gao

    2016-11-01

    Full Text Available In this paper, a Rankine cycle test system is established to recover exhaust energy from a 2.0 L gasoline engine. Experiments on the system’s performance are carried out under various working conditions. The experimental results indicate that the recovery power of the expander is strongly related to the load and speed of the gasoline engine. It is found that when the output power of the gasoline engine is 39.8–76.6 kW, the net power of the expander is 1.8–2.97 kW, which is equivalent to 3.9%–4.9% of the engine power. The performance simulation shows that the mass flow rate, power output, and isentropic efficiency of the piston expander are directly determined by the intake valve timing. Selecting a suitable intake valve timing can optimize the performance of the expander. The simulation results show that a 1 kW increment in power can be obtained only by selecting an optimum intake open timing. The experimental results further verify that the single-valve piston expander, because of its small dimensions, simple structure, and high speed, is appropriate, and has great potential for energy recovery of gasoline engine exhaust and has good prospects for engineering applications.

  9. Cardiovascular effects of right ventricle-pulmonary artery valved conduit implantation in experimental pulmonic stenosis

    International Nuclear Information System (INIS)

    Saida, Y.; Tanaka, R.; Fukushima, R.; Hoshi, K.; Hira, S.; Soda, A.; Iizuka, T.; Ishikawa, T.; Nishimura, T.; Yamane, Y.

    2009-01-01

    Right ventricle (RV)-pulmonary artery (PA) valved conduit (RPVC) implantation decreases RV systolic pressure in pulmonic stenosis (PS) by forming a bypass route between the RV and the PA. The present study evaluates valved conduits derived from canine aortae in a canine model of PS produced by pulmonary artery banding (PAB). Pulmonary stenosis was elicited using PAB in 10 conditioned beagles aged 8 months. Twelve weeks after PAB, the dogs were assigned to one group that did not undergo surgical intervention and another that underwent RPVC using denacol-treated canine aortic valved grafts (PAB+RPVC). Twelve weeks later, the rate of change in the RV-PA systolic pressure gradient was significantly decreased in the PAB+RPVC, compared with the PAB group (60.5+-16.7% vs. 108.9+-22.9%; p0.01). In addition, the end-diastolic RV free wall thickness (RVFWd) was significantly reduced in the PAB+RPVC, compared with the PAB group (8.2+-0.2 vs. 9.4+-0.7 mm; p0.05). Thereafter, regurgitation was not evident beyond the conduit valve and the decrease in RV pressure overload induced by RPVC was confirmed. The present results indicate that RPVC can be performed under a beating heart without cardiopulmonary bypass and adapted to dogs with various types of PS, including 'supra valvular' PS or PS accompanied by dysplasia of the pulmonary valve. Therefore, we consider that this method is useful for treating PS in small animals

  10. Mitral valve reconstruction in Barlow disease: long-term echographic results and implications for surgical management.

    Science.gov (United States)

    Jouan, Jérôme; Berrebi, Alain; Chauvaud, Sylvain; Menasché, Philippe; Carpentier, Alain; Fabiani, Jean-Noël

    2012-04-01

    Owing to the complexity of the underlying lesions, Barlow disease remains a challenge for surgeons performing mitral valve repair. We aimed to assess whether our most recent results involving several surgeons were comparable with those of a previous experience in which mitral valve repair was performed by a more limited group of surgeons. From September 2000 to January 2007, 200 patients with Barlow disease (135 men and 65 women; mean age, 56 ± 13 years) were referred to our institution for surgical treatment of their mitral regurgitation. We retrospectively analysed the mitral lesions characteristics, the surgical techniques used, and clinical outcomes. Follow-up echocardiograms were biannually reviewed. Lesions comprised annular dilatation, excess tissue, and leaflet prolapse in all cases. The most frequent prolapsed segments were P2 (88.5%; n = 177) and A2 (55.5%; n = 111). Annular calcifications and restrictive valvular motion were associated in 20% (n = 40). Repair was feasible in 94.7% (n = 179/189) of non-redo interventions. Immediate postoperative echocardiography showed residual mitral regurgitation greater than 1+ in 6 cases; these patients were all reoperated on within the next months. Operative mortality was 1.5% (n = 3). Mean follow-up was 77.5 ± 25.6 months. At 8 years postoperatively, overall survival was 88.6% ± 3.1%, freedom from reintervention was 95.3% ± 1.7%, and freedom from late recurrent moderate mitral regurgitation (>2+) was 90.2% ± 3.1% Provided that the fundamental principles of mitral valve reconstruction are respected, the surgical techniques are highly reproducible with good long-term results, similar to those published during the pioneering phase of this surgery. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. Transcriptomic profiling of peripheral blood nucleated cells in dogs with and without clinical signs of chronic mitral valve disease

    Directory of Open Access Journals (Sweden)

    Garncarz Magdalena

    2014-03-01

    Full Text Available The aim of the study was to demonstrate differences in the gene expression of signalling pathways between healthy dogs and dogs with chronic mitral valve disease in different heart failure groups. Blood samples were collected from 49 dogs of various breeds between 1.4 and 15.2 years of age. Isolated RNA samples were analysed for quality and integrity and the gene expression profile was determined. The study demonstrated that nucleated cells from peripheral blood can be used to assess the status of heart failure in dogs. Furthermore, significant differences in the expression of the genes were noticed between healthy dogs and dogs with clinical signs of chronic mitral valve disease. This is a preliminary non-invasive study showing the feasibility of genetic testing from peripheral blood nucleated cells, which at the same time has made it possible to set the future directions of genetic studies in clinical cases of canine chronic mitral valve disease.

  12. Comparative effects of amlodipine and benazepril on left atrial pressure in dogs with experimentally-induced mitral valve regurgitation.

    Science.gov (United States)

    Suzuki, Shuji; Fukushima, Ryuji; Ishikawa, Taisuke; Yamamoto, Yuta; Hamabe, Lina; Kim, Soomin; Yoshiyuki, Rieko; Machida, Noboru; Tanaka, Ryou

    2012-09-18

    One of the purposes of treatment for dogs with mitral regurgitation (MR) is lowering left atrial pressure (LAP). There has been few study of the amlodipine in dogs with MR and amlodipine's effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h) vs benazepril (0.5 mg/kg PO q12h), on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p benazepril treatment (13.19 ± 3.47 mmHg, p > .05). LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA) of the amlodipine treatment was significantly lower (p benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  13. Triple leaflet perforation due to endocarditis in aortic valve complicated by pneumonia and exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Elton Soydan

    2015-09-01

    Full Text Available Valve perforation complicating infective endocarditis has been for decades a bad sign leading to severe valve destruction, intractable heart failure and even death if surgical therapy is not administered in time. Here we present a 57 years old male patient inadvertently diagnosed with pneumonia and chronic obstructive pulmonary disease exacerbation in another hospital. After 20 days of broad spectrum antibiotics and bronchodilator therapy no improvement was achieved. During examination a severe aortic regurgitation was recognized. Immediately after, patient was transferred to our hospital for aortic valve surgery evaluation. Transthorasic echocardiography (TTE showed a severe aortic regurgitation and vegetation like echogenicity over the noncoronary leaflet. An aortic valve replacement surgical therapy was decided. During the aortic valve excision underneath the vegetations, multiple small perforations in all the three leaflets were noticed. The destructed valve was excised and a mechanical aortic prosthesis (St Jude No: 23, MN, USA was successfully replaced. After 14 days of treatment patient was healthily discharged.

  14. Pulmonary abnormalities in mitral valve disease. Comparison between pulmonary wedge pressure, regional pulmonary blood flow and chest films

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, L H; Andersen, Jr, P E [Odense Univ. (Denmark)

    1978-01-01

    Chest films, right sided heart catheterization, and measurement of the regional lung perfusion, using /sup 133/Xe, were carried out 31 times on patients with mitral valve disease. A relationship was found between the radiologic evaluation in 3 grades, and the values of pulmonary wedge pressure and the apical and basal perfusion. Changes in flow distribution as reflected in altered appearance of the vessels and the presence of interstitial edema were found to be the most sensitive factors in the evaluation of pulmonary wedge pressure. Chest radiography was thus found suitable for the evaluation of pulmonary wedge pressure in mitral valve disease.

  15. Water-hammer experimental set-up and water-hammer experimental study for new types of check valve applied to PWR

    International Nuclear Information System (INIS)

    Liu Hanxun.

    1985-01-01

    This paper describes a self-designed constant temperature water-hammer shock test rig with stainless steel loop in which deionized water is used as working medium. To conduct water-hammer shock simulation tests for the countercurrent phenomenon occurred in the process of shutting, stopping, parallelling and switching the coolant loops of nuclear reactor, a specially designed four-way switching valve and its pneumatic mechanism are used. Water-hammer experimental study is performed for two types of PWR's nonshock check valve with diameter of 150 mm and 200 mm simultaneously. Transient performance of the shock waves, magnitude of their peaks and durations of their fluctuation, is obtained. Some analyses for existing calculational method on water-hammer are made

  16. Huntington disease: Experimental models and therapeutic perspectives

    International Nuclear Information System (INIS)

    Serrano Sanchez, Teresa; Blanco Lezcano, Lisette; Garcia Minet, Rocio; Alberti Amador, Esteban; Diaz Armesto, Ivan and others

    2011-01-01

    Huntington's disease (HD) is a degenerative dysfunction of hereditary origin. Up to date there is not, an effective treatment to the disease which having lapsed 15 or 20 years advances inexorably, in a slow form, toward the total inability or death. This paper reviews the clinical and morphological characteristics of Huntington's disease as well as the experimental models more commonly used to study this disease, having as source the articles indexed in Medline data base, published in the last 20 years. Advantages and disadvantages of all experimental models to reproduce the disease as well as the perspectives to therapeutic assay have been also considered. the consent of outline reported about the toxic models, those induced by neurotoxins such as quinolinic acid, appears to be the most appropriate to reproduce the neuropathologic characteristic of the disease, an genetic models contributing with more evidence to the knowledge of the disease etiology. Numerous treatments ameliorate clinical manifestations, but none of them has been able to stop or diminish the affectations derived from neuronal loss. At present time it is possible to reproduce, at least partially, the characteristics of the disease in experimentation animals that allow therapy evaluation in HD. from the treatment view point, the more promissory seems to be transplantation of no neuronal cells, taking into account ethical issues and factibility. On the other hand the new technology of interference RNA emerges as a potential therapeutic tool for treatment in HD, and to respond basic questions on the development of the disease.

  17. Plasma and tissue oxidative stress index in patients with rheumatic and degenerative heart valve disease.

    Science.gov (United States)

    Rabus, Murat; Demirbağ, Recep; Sezen, Yusuf; Konukoğlu, Oğuz; Yildiz, Ali; Erel, Ozcan; Zeybek, Rahmi; Yakut, Cevat

    2008-12-01

    We investigated whether patients with rheumatic and degenerative heart valve disease (HVD) differed with regard to plasma and tissue oxidative stress index (OSI). The study included 56 patients who underwent valve replacement due to rheumatic (n=32; 15 males; mean age 47+/-10 years) and degenerative (n=24; 13 males; mean age 55+/-12 years) HVD. Plasma and tissue total oxidative status (TOS) and total antioxidative capacity (TAC) levels were measured and OSI was calculated. Patients with degenerative HVD had significantly higher age, increased interventricular septum thickness, and higher frequency of aortic stenosis, whereas the incidence of mitral stenosis was higher in patients with rheumatic HVD (p0.05). Tissue TAC was significantly lower in patients with rheumatic HVD (p=0.027), whereas tissue TOS and OSI were similar between the two HVD groups (p>0.05). In bivariate analysis, plasma OSI did not show any correlation with clinical, laboratory, and echocardiographic variables (p>0.05). Our data show that plasma and tissue OSI levels are similar in patients with rheumatic and degenerative HVD.

  18. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  19. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.

    Science.gov (United States)

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-06-01

    Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (PALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.

  20. Experimental analysis of axial and radial stress distribution in soft materials used for petrochemical valve stem sealing package

    Science.gov (United States)

    Ripeanu, R. G.; Ispas, A.; Ispas, D.

    2017-02-01

    Paper presents experimental results obtained by authors regarding pressure values and distribution, by using a special pressure sensitive paper, type FujiFilm and adequate hardware equipment and a soft program FPD810 Win. Was obtained the proper axial force related for different materials in order to respect the valves sealing demands. Were showed that, pressure maps obtained depends of the construction of sealing package, density of the preformed band rings and corrected sealing replacing on location in case of square braided cord used.

  1. Management of tricuspid regurgitation in congenital heart disease: is survival better with valve repair?

    Science.gov (United States)

    Said, Sameh M; Dearani, Joseph A; Burkhart, Harold M; Connolly, Heidi M; Eidem, Ben; Stensrud, Paul E; Schaff, Hartzell V

    2014-01-01

    Tricuspid valve (TV) regurgitation in congenital heart disease includes a heterogeneous group of lesions, and few series have documented the outcomes. We reviewed the records of 553 patients with congenital heart disease who had undergone TV surgery for tricuspid regurgitation from January 1993 to December 2010. Patients with Ebstein malformation were excluded. Their mean age was 32 ± 21 years, and 300 were female (54%). The most common diagnoses were conotruncal anomaly in 216 patients (39%), previous ventricular septal defect closure in 83 (15%), atrioventricular septal defect in 77 (14%), and pulmonary atresia with an intact ventricular septum in 11 (2%). Preoperative right-sided heart failure was present in 124 patients (22%), and 55 patients (10%) had pulmonary hypertension. TV repair was performed in 442 (80%) and TV replacement in 111 (20%) patients. Repeat sternotomy was performed in 415 patients (75%). Previous TV repair was present in 44 patients (8%); of these, 17 (38.6%) underwent repeat TV repair. The overall early mortality was 3.1% (17 patients) and was 2.5% for TV repair and 5.4% for TV replacement (P = .001). The mean follow-up period was 4.5 ± 4.1 years (maximum, 18). The overall survival at 1, 5, and 10 years was 97%, 93%, and 85%, respectively. Survival was better for patients with repair than with replacement. TV repair was an independent predictor of better survival (P = .001). Important tricuspid regurgitation can occur with a variety of congenital diagnoses. Early mortality is low and late survival is superior with tricuspid repair than with valve replacement. Surgical treatment of tricuspid regurgitation in congenital heart disease should be performed before the onset of heart failure. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  2. Comparative long-term results of mitral valve repair in adults with chronic rheumatic disease and degenerative disease: is repair for "burnt-out" rheumatic disease still inferior to repair for degenerative disease in the current era?

    Science.gov (United States)

    Dillon, Jeswant; Yakub, Mohd Azhari; Kong, Pau Kiew; Ramli, Mohd Faizal; Jaffar, Norfazlina; Gaffar, Intan Fariza

    2015-03-01

    Mitral valve repair is perceived to be of limited durability for advanced rheumatic disease in adults. We aim to examine the long-term outcomes of repair for rheumatic disease, identify predictors of durability, and compare with repair for degenerative disease. Rheumatic and degenerative mitral valve repairs in patients aged 40 years or more were prospectively analyzed. The primary outcomes investigated were mortality, freedom from reoperation, and valve failure. Logistic regression analysis was performed to define predictors of poor outcome. Between 1997 and 2011, 253 rheumatic and 148 degenerative mitral valves were repaired. The age of patients in both groups was similar, with a mean of 54.1 ± 8.4 years versus 55.6 ± 7.3 years (P = .49). Freedom from reoperation for rheumatic valves at 5 and 10 years was 98.4%, comparable to 95.3% (P = .12) for degenerative valves. Freedom from valve failure at 5 and 10 years was 91.4% and 81.5% for rheumatic repairs and 82.5% and 75.4% for degenerative repairs, respectively (P = .15). The presence of residual mitral regurgitation greater than 2+ before discharge was the only significant independent predictor of reoperation, whereas residual mitral regurgitation greater than 2+ and leaflet procedures were significant risk factors for valve failure. The durability of rheumatic mitral valve repair in the current era has improved and is comparable to the outstanding durability of repairs for degenerative disease, even in the adult rheumatic population. Modifications of standard repair techniques, adherence to the importance of good leaflet coaptation, and strict quality control with stringent use of intraoperative transesophageal echocardiography have all contributed to the improved long-term results. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. The changing course of aortic valve disease in Scotland: temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis.

    Science.gov (United States)

    Berry, Colin; Lloyd, Suzanne M; Wang, Yanzhong; Macdonald, Alyson; Ford, Ian

    2013-06-01

    To investigate the contemporary clinical course of aortic valve disease types. We performed a retrospective population-level epidemiological study of hospitalized care in Scotland from 1 January 1997 to 31 December 2005 using electronic case identification of hospital admissions and deaths. Time-to-event analyses were performed using Cox Proportional-Hazards models. A total of 19 733 adults with an index hospitalization and a final diagnosis of non-congenital aortic valve disease were identified. Aortic stenosis, aortic insufficiency, mixed aortic valve disease, or unspecified aortic valve disease occurred in 13 220 (67.0%), 2807 (14.2%), 699 (3.5%), and 3007 (15.2%), individuals, respectively. The majority of hospitalizations occurred in elderly persons aged 80 and older. In total, 9981 (50.6%) patients had died by 31 December 2006. When compared with aortic stenosis, the risk of death was less with aortic insufficiency [hazard ratio (95% confidence interval) 0.79 (0.74, 0.84)] and mixed aortic valve disease [0.83 (0.74, 0.93)]. Female gender, admission year, and hypertension were associated with lower mortality in patients with aortic stenosis. Patients with aortic stenosis had increased risk of death or heart failure (adjusted P valve replacement of whom 73.2% had aortic stenosis, 11.9% aortic valve disease (unspecified),10.0% aortic insufficiency, and 4.9% aortic stenosis with insufficiency. Patients with aortic stenosis with insufficiency had increased likelihood of aortic valve replacement [1.19 (1.02, 1.38)]. Age, female gender, and co-morbidity reduced the likelihood of aortic valve replacement. The incidence of aortic valve stenosis has substantially increased in Scotland in recent years. Aortic stenosis predicts morbidity and mortality when compared with other types of aortic valve disease.

  4. Native valve disease in patients with non-valvular atrial fibrillation on warfarin or rivaroxaban

    Science.gov (United States)

    Breithardt, Günter; Baumgartner, Helmut; Berkowitz, Scott D; Hellkamp, Anne S; Piccini, Jonathan P; Lokhnygina, Yuliya; Halperin, Jonathan L; Singer, Daniel E; Hankey, Graeme J; Hacke, Werner; Becker, Richard C; Nessel, Christopher C; Mahaffey, Kenneth W; Califf, Robert M; Fox, Keith A A; Patel, Manesh R

    2016-01-01

    Objective To compare the characteristics and outcomes of patients with atrial fibrillation (AF) and aortic stenosis (AS) with patients with AF with mitral regurgitation (MR) or aortic regurgitation (AR) and patients without significant valve disease (no SVD). Methods Using Rivaroxaban Once-Daily, Oral, Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF) data, we analysed efficacy and safety outcomes, adjusting hazard ratios (HRs) for potential confounders using Cox regression analysis. Results Among 14 119 intention-to-treat ROCKET AF trial patients, a trial that excluded patients with mitral stenosis or artificial valve prosthesis, 214 had AS with or without other valve abnormalities, 1726 had MR or AR and 12 179 had no SVD. After adjusting for prognostic factors, the composite of stroke, systemic embolism or vascular death increased approximately twofold in patients with AS (AS 10.84, MR or AR 4.54 and no SVD 4.31 events per 100 patient-years, p=0.0001). All-cause death also significantly increased (AS 11.22, MR or AR 4.90 and no SVD 4.39 events per 100 patient-years, p=0.0003). Major bleeding occurred more frequently in AS (adjusted HR 1.61, confidence intervals (CI) 1.03 to 2.49, p<0.05) and MR or AR (HR 1.30, 1.07 to 1.57, p<0.01) than in no SVD, but there was no difference between AS and MR or AR (HR 1.24, 0.78 to 1.97). The relative efficacy of rivaroxaban versus warfarin was consistent among patients with and without valvular disease. Rivaroxaban was associated with higher rates of major bleeding than warfarin in patients with MR or AR (HR 1.63, 1.15 to 2.31). Conclusions We found that patients with AF and AS on oral anticoagulants may have distinctly different efficacy and safety outcomes than patients with MR or AR or no SVD. Trial registration number NCT00403767; Post-results. PMID:26888572

  5. [Left-sided native valve endocarditis by coagulase-negative staphylococci: an emerging disease].

    Science.gov (United States)

    Haro, Juan Luis; Lomas, José M; Plata, Antonio; Ruiz, Josefa; Gálvez, Juan; de la Torre, Javier; Hidalgo-Tenorio, Carmen; Reguera, José M; Márquez, Manuel; Martínez-Marcos, Francisco; de Alarcón, Arístides

    2008-05-01

    To describe the epidemiological, clinical, and prognostic characteristics of patients with left-sided native valve endocarditis (LNVE) caused by coagulase-negative staphylococci (CoNS). Prospective multicenter study of endocarditis cases reported in the Andalusian Cohort for the Study of Cardiovascular Infections between 1984 and 2005. Among 470 cases of LNVE, 39 (8.3%) were caused by CoNS, a number indicating a 30% increase in the incidence of this infection over the last decade. The mean age of affected patients was 58.32 +/- 15 years and 27 (69.2%) were men. Twenty-one patients (53.8%) had previous known valve disease and half the episodes were considered nosocomial (90% of them from vascular procedures). Median time interval from the onset of symptoms to diagnosis was 14 days (range: 1-120). Renal failure (21 cases, 53.8%), intracardiac damage (11 cases, 28.2%), and central nervous system involvement (10 cases, 25.6%) were the most frequent complications. There were only 3 cases (7.7%) of septic shock. Surgery was performed in 18 patients (46.2%). Nine patients (23.1%) died, overall. Factors associated with higher mortality in the univariate analysis were acute renal failure (P = 0.023), left-sided ventricular failure (P = 0.047), and time prior to diagnosis less than 21 days (P = 0.018). As compared to LNVE due to other microorganisms, the patients were older (P = 0.018), had experienced previous nosocomial manipulation as the source of bacteremia (P < 0.001), and developed acute renal failure more frequently (P = 0.001). Mortality of LNVE due to CoNS was lower than mortality in Staphylococcus aureus infection, but higher than in Streptococcus viridans infection. Left-sided native valve endocarditis due to CoNS is now increasing because of the ageing of the population. This implies more frequent invasive procedures (mainly vascular) as a consequence of the concomitant disease. Nonetheless, the mortality associated with LNVE due to CoNS does not seem to be

  6. Experimental Investigation of a Multi-Cycle Single-Tube Pulse Detonation Rocket Engine with a Coaxial Rotary Valve

    Science.gov (United States)

    Matsuoka, Ken; Esumi, Motoki; Ikeguchi, Ken Bryan; Kasahara, Jiro; Matsuo, Akiko; Funaki, Ikkoh

    We developed a novel coaxial rotary valve for a multi-tube PDE. Since this single valve can supply three different gases (fuel, oxidizer and purge gas) into a combustor, the unification of the valve systems for three different gases is possible by using our newly designed valve. A PDRE system can be simple and lightweight by using this valve, and thus its thrust-weight ratio can be increased. We proposed the design of a multi-tube rotary-valved PDRE system by this rotary valve. Moreover, in preparation for a multi-tube rotary-valved PDRE, we carried out the multi-cycle operation experiment by the single-tube rotary-valved PDRE system. The combustion wave velocity was measured to confirm the operation of the PDRE system. Deflagration-to-detonation transition (DDT) was confirmed and DDT distance decreased under the condition of high operation frequency. In addition, a maximum operation frequency was 159 Hz.

  7. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease.

    Science.gov (United States)

    Meurs, Kathryn M; Olsen, Lisbeth H; Reimann, Maria J; Keene, Bruce W; Atkins, Clarke E; Adin, Darcy; Aona, Brent; Condit, Julia; DeFrancesco, Teresa; Reina-Doreste, Yamir; Stern, Joshua A; Tou, Sandra; Ward, Jessica; Woodruff, Kathleen

    2018-02-01

    Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated with alterations in ACE activity at different stages of cardiac disease. Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Forty-three dogs were homozygous for the ACE polymorphism; five were heterozygous and 25 were homozygous wild type. The mean age and the median severity of disease were not different for dogs with the polymorphism and dogs with the wild-type sequence. The median baseline ACE activity was significantly lower for the ACE polymorphism (27.0 U/l) than the wild-type sequence dogs (31.0 U/l) (P=0.02). Dogs with more severe disease and the ACE polymorphism had significantly lower levels of ACE activity than dogs with the wild-type sequence (P=0.03). The CKCS appears to have a high prevalence of the ACE variant. Dogs with the ACE variant had lower levels of ACE activity even in more advanced mitral valve disease than dogs without the variant. The clinical significance of this finding and its impact on the need for ACE-I in dogs with the polymorphism and heart disease deserves further study.

  8. Comparative effects of amlodipine and benazepril on Left Atrial Pressure in Dogs with experimentally-induced Mitral Valve Regurgitation

    Directory of Open Access Journals (Sweden)

    Suzuki Shuji

    2012-09-01

    Full Text Available Abstract Background One of the purposes of treatment for dogs with mitral regurgitation (MR is lowering left atrial pressure (LAP. There has been few study of the amlodipine in dogs with MR and amlodipine’s effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h vs benazepril (0.5 mg/kg PO q12h, on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Results Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p  .05. LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA of the amlodipine treatment was significantly lower (p  Conclusions LAP was significantly decreased after amlodipine treatment in dogs with surgically-induced MR but not after benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  9. Expression Profiling of Circulating MicroRNAs in Canine Myxomatous Mitral Valve Disease

    Directory of Open Access Journals (Sweden)

    Qinghong Li

    2015-06-01

    Full Text Available MicroRNAs (miRNAs are small non-coding RNAs that have shown promise as noninvasive biomarkers in cardiac disease. This study was undertaken to investigate the miRNA expression profile in dogs with myxomatous mitral valve disease (MMVD. 277 miRNAs were quantified using RT-qPCR from six normal dogs (American College of Veterinary Internal Medicine Stage A, six dogs with MMVD mild to moderate cardiac enlargement (ACVIM Stage B1/B2 and six dogs with MMVD and congestive heart failure (ACVIM Stage C/D. Eleven miRNAs were differentially expressed (False Discovery Rate < 0.05. Dogs in Stage B1/B2 or C/D had four upregulated miRNAs, including three cfa-let-7/cfa-miR-98 family members, while seven others were downregulated, compared to Stage A. Expression of six of the 11 miRNAs also were significantly different between dogs in Stage C/D and those in Stage B1/B2. The expression changes were greater as disease severity increased. These miRNAs may be candidates for novel biomarkers and may provide insights into genetic regulatory pathways in canine MMVD.

  10. Role of diastolic function indices in the risk stratification of patients with mixed aortic valve disease.

    Science.gov (United States)

    Egbe, Alexander C; Khan, Arooj R; Boler, Amber; Said, Sameh M; Geske, Jeffrey B; Miranda, William R; Akintoye, Emmanuel; Connolly, Heidi M; Warnes, Carole A; Oh, Jae K

    2018-06-01

    Determine the role of diastolic function indices in pre-operative and post-operative risk stratification in patients with moderate mixed aortic valve disease (MAVD). A retrospective study was conducted of asymptomatic patients with moderate MAVD (a combination of moderate aortic stenosis and moderate aortic regurgitation) and an ejection fraction of 50% or more who were followed up at Mayo Clinic from 1 January 2004, to 31 December 2013. A pre-requisite for inclusion in the study was assessment of diastolic function involving at least three of the following indices: tissue Doppler early diastolic velocity (e'), mitral inflow early velocity (E), tricuspid regurgitation velocity, and left atrial volume index. Primary endpoints were aortic valve replacement (AVR) or cardiac death while secondary endpoints were cardiovascular adverse events (CAEs) after AVR. We defined CAEs as stroke, heart failure hospitalization, severe left ventricular dysfunction, and cardiac death. There were 214 patients (age 61 ± 8 years, men 146 [68%]) followed for 6.1 ± 2.3 years during which 162 (76%) AVRs and 11 (5%) cardiac deaths occurred. The multivariable risk factors for cardiac death or AVR were relative wall thickness (RWT) > 0.42 [hazard ratio (HR), 1.88 [95% CI, 1.28-2.59]; P = 0.001] and average E/e' >14 (HR, 1.94 [95% CI, 1.29-3.01]; P = 0.02). Freedom from CAE after AVR was significantly lower in the patients with baseline RWT >0.42 or mean E/e' >14 than the other patients: 79% (95% CI 74-83%) vs. 94% (95% CI 89-98%) at 3 years (P = 0.03). The presence of RWT >0.42 or E/e' >14 identifies a high-risk patient subset whose risk for cardiovascular morbidities persists even after AVR.

  11. Valvular heart disease: assessment of valve morphology and quantification using MR

    International Nuclear Information System (INIS)

    Schwitter, J.

    2000-01-01

    For clinical evaluation and decision-making in patients with valvular heart disease, the diagnostic armamentarium expands steadily. This evolution makes it difficult to choose the most appropriate approach for a specific valvular lesion. It may also reflect our uncertainty of what are the findings that best predict clinical outcome of patients, e. g. after surgery. Accordingly, for each type of valvular lesion, some pathophysiological considerations are stated in order to derive the most important measures that would allow optimal guidance of patients. Based on these considerations the value of an MR study is discussed for each valvular lesion. Newest advances in MR technology allow for highly accurate measurements of regurgitant volumes and hence, MR may be the method of choice for a quantitative evaluation of regurgitant valves. For assessment of stenosis severity, measurement of transvalvular pressure gradient is an appropriate measure and MR may not confer benefits over echocardiography, provided the ultrasound window is adequate (and stroke volume is in the normal range). With respect to surgical treatment, valvular morphology is of pivotal importance, particularly for the mitral valve, and echocardiography still appears to be the first line method. Little data relate lesion severity and/or morphology to clinical outcome. Conversely, the extent of cardiac adaptation to pressure- and/or volume-overload, i. e. ventricular remodeling, is a strong predictor of outcome, and is therefore most important for final judgement of the patient. For assessment of left and right ventricular remodeling, echocardiography typically provides all the necessary information. However, in special cases with discrepant findings, with inadequate ultrasound window, or in the preoperative work-up, MR may provide important information regarding cardiac adaptation to valvular lesion. (orig.) [de

  12. Outcomes of Patients With Severe Chronic Lung Disease Who Are Undergoing Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Suri, Rakesh M; Gulack, Brian C; Brennan, J Matthew; Thourani, Vinod H; Dai, Dadi; Zajarias, Alan; Greason, Kevin L; Vassileva, Christina M; Mathew, Verghese; Nkomo, Vuyisile T; Mack, Michael J; Rihal, Charanjit S; Svensson, Lars G; Nishimura, Rick A; O'Gara, Patrick T; Holmes, David R

    2015-12-01

    In this study, we sought to determine the clinical outcomes after transcatheter aortic valve replacement (TAVR) among patients with chronic lung disease (CLD) and to evaluate the safety of transaortic versus transapical alternate access approaches in patients with varying severities of CLD. Clinical records for patients undergoing TAVR from 2011 to 2014 in The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were linked to Medicare hospital claims (n = 11,656). Clinical outcomes were evaluated across strata of CLD severity, and the risk-adjusted association between access route and post-TAVR mortality was determined among patients with severe CLD. In this cohort (median age, 84 years; 51.7% female), moderate to severe CLD was present in 27.7% (14.3%, moderate; 13.4%, severe). Compared with patients with no or mild CLD, patients with severe CLD had a higher rate of post-TAVR mortality to 1-year (32.3% versus 21.0%; adjusted hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.31 to 1.66), as did those with moderate CLD (25.5%; adjusted HR, 1.16; 95% CI, 1.03 to 1.30). The adjusted rate of mortality was similar for transapical versus transaortic approaches to 1 year (adjusted HR, 1.17; 95% CI, 0.83 to 1.65). Moderate or severe CLD is associated with an increased risk of death to 1-year after TAVR, and among patients with severe CLD, the risk of death appears to be similar with either transapical or transaortic alternate-access approaches. Further study is necessary to understand strategies to mitigate risk associated with CLD and the long-term implications of these findings. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Biopterin status in dogs with myxomatous mitral valve disease is associated with disease severity and cardiovascular risk factors

    DEFF Research Database (Denmark)

    Reimann, Maria Josefine; Häggström, J.; Mortensen, Alan

    2014-01-01

    BACKGROUND: Endothelial dysfunction (ED) has been suggested to be associated with myxomatous mitral valve disease (MMVD) in dogs. Tetrahydrobiopterin (BH4) is an important cofactor for production of the endothelium-derived vasodilator nitric oxide (NO). Under conditions of oxidative stress, BH4...... is oxidized to the biologically inactive form dihydrobiopterin (BH2). Thus, plasma concentrations of BH2 and BH4 may reflect ED and oxidative stress. OBJECTIVE: To determine plasma concentrations of BH2 and BH4 in dogs with different degrees of MMVD. ANIMALS: Eighty-four privately owned dogs grouped according...... to ACVIM guidelines (37 healthy control dogs including 13 Beagles and 24 Cavalier King Charles Spaniels [CKCSs], 33 CKCSs with MMVD of differing severity including 18 CKCSs [group B1] and 15 CKCSs [group B2], and 14 dogs of different breeds with clinical signs of congestive heart failure [CHF] because...

  14. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  15. CLINICAL AND FUNCTIONAL ASSESSMENT OF THE BIOLOGICAL PROSTHESIS “ASPIRE” FOR SURGICAL CORRECTION OF MITRAL VALVE DISEASE

    Directory of Open Access Journals (Sweden)

    S. G. Esin

    2015-01-01

    Full Text Available Aim: To assess clinical and functional efficacy of implanted biological prosthesis “ASPIRE” (manufactured by Vascutek for correction of mitral valve disease.Materials and methods: From October 2008 to December 2013, biological prostheses “ASPIRE” (Vascutek were implanted to 34 patients with mitral valve disease (mean age 63.59 ± 4.96 years, 79.4% female. From these, 24 patients had mitral stenosis and 10 patients had mitral insufficiency. 73.5% of all patients had heart failure Strazhesko-Vasilenko IIA grade and 85.3% of patients had chronic heart failure NYHA III. Isolated mitral valve replacement was performed only in 8 (23.5% of patients. In 22 (64.7% of cases mitral valve replacement was combined with tricuspid valvuloplasty in various modifications. Duration of cardiopulmonary bypass and of aortic clamping was 88.09 ± 25.95 and 65.68 ± 25.51 minutes, respectively. Before and after surgery all patients underwent echocardiographic assessment and clinical assessment of their general status.Results: In-hospital mortality was 5.88% (n = 2 and was related to multiorgan failure in the early postoperative period. All 32 (94.12% surviving patients improved with decrease or complete disappearance of heart failure. Postoperative complications were typical for cardiac surgery. There were no episodes of embolism, structural dysfunction, thrombosis of the prosthesis and endocarditis of the prosthesis in the early postoperative period. Pressure gradients across prosthetic valves were not high and corresponded to good clinical and hemodynamic results in the early postoperative period.Conclusion: Taking into account good immediate results of mitral valve replacement, as well as no need in lifelong anticoagulation in patients with multiple concomitant disorders, implantation of the biological prosthesis “ASPIRE” (Vascutek could become a procedure of choice for correction of valve abnormalities in patients above 65 years. For more comprehensive

  16. Thallium - 201 miocardial perfusion scintigraphy in patients with mitral valve prolapse, with and without coronary artery disease

    International Nuclear Information System (INIS)

    Moraes, A.G. de; Sousa, J.E.M.R.; Thom, A.F.; Martins, L.R.F.; Meneghelo, R.S.; Pimentel Filho, W.A.; Marioni Filho, H.; Gimenes, V.M.L.; Pontes Junior, S.C.

    1981-01-01

    Thirty patients with precordial pain and mitral valve prolapse diagnosed by cineangiography and M-mode echocardiography were submitted to Thallium-201 myocardial stress perfusion scintillography. They were divided into two groups: group I - eighteen patients with mitral valve prolapse and normal coronary arteries, of which ten presented positive exercise stress test (55.6%); eight patients had a negative exercise test. Thallium-201 myocardial stress perfusion scintillagraphy was normal in 14 (77.8%) patients, and four with positive stress perfursion scintillography, (three with inferior perfusion defects and one with a lateral one); group II - twelve patients with mitral valve prolapse and severe coronary artery disease (stenosis >= 60% in at least one main vessel of the coronary circulation), of which nine presented positive exercise stress test (75%) and three negative. Thallium-201 exercise myocardial perfusion scintillography was abnormal in nine (75%), six with stress induced ischemia and three with resting defect. Myocardial perfusion scintillography with Thallium-201 was more sensitive to detect the presence of coronary artery disease in patients with mitral valve prolapse (MVP) than the exercise stress test in spite of the fact that a small number of patients (22%) with MVP and normal coronary arteries exhibited abnormal myocardial stress perfusion during scintillography. (Author) [pt

  17. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    International Nuclear Information System (INIS)

    Ruparelia, Neil; Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio; Latib, Azeem

    2015-01-01

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  18. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Neil [San Raffaele Scientific Institute, Milan (Italy); Imperial College, London (United Kingdom); Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio [San Raffaele Scientific Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [San Raffaele Scientific Institute, Milan (Italy)

    2015-09-15

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  19. Aldosterone breakthrough in dogs with naturally occurring myxomatous mitral valve disease.

    Science.gov (United States)

    Ames, M K; Atkins, C E; Eriksson, A; Hess, A M

    2017-06-01

    Aldosterone breakthrough (ABT) is the condition in which angiotensin converting enzyme inhibitors (ACEIs) and/or angiotensin receptor blockers fail to effectively suppress the activity of the renin angiotensin aldosterone system. The objective of this study was to determine if ABT occurs in dogs with naturally occurring myxomatous mitral valve disease receiving an ACEI, using the urine aldosterone to creatinine ratio (UAldo:C) as a measure of renin angiotensin aldosterone system activation. This study includes 39 dogs with myxomatous mitral valve disease. A UAldo:C cut-off definition (derived from a normal population of healthy, adult, and client-owned dogs) was used to determine the prevalence of ABT in this population. Spearman analysis and univariate logistic regression were used to evaluate the relationship between UAldo:C and ABT (yes/no) and eight variables (age, serum K + concentration, serum creatinine concentration, ACEI therapy duration and ACEI dosage, furosemide therapy duration and furosemide dosage, and urine sample storage time). Finally, the UAldo:C in dogs receiving spironolactone, as part congestive heart failure (CHF) therapy, was compared to dogs with CHF that were not receiving spironolactone. The prevalence of ABT was 32% in dogs with CHF and 30% in dogs without CHF. There was no relationship between either the UAldo:C or the likelihood of ABT and the eight variables. Therapy with spironolactone lead to a significant elevation of the UAldo:C. Using the UAldo:C and a relatively stringent definition of ABT, it appears that incomplete RAAS blockade is common in dogs with MMVD receiving an ACEI. The prevalence of ABT in this canine population mirrors that reported in humans. While the mechanism of ABT is likely multifactorial and still poorly understood, the proven existence of ABT in dogs offers the potential to improve the prognosis for MMVD with the addition of a mineralocorticoid receptor blocker to current therapeutic regimens

  20. AN EXPERIMENTAL INVESTIGATION OF THE EFFECTS OF VARIABLE VALVE TIMING ON THE PERFORMANCE IN SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    Ali AKBAŞ

    2001-01-01

    Full Text Available In this study, an alternative prototype has been designed and constructed for variable valve timing systems which are used in spark ignition engines. The effects of intake valve timing and lift changing on engine performance have been investigated without changing the opening duration of the valves. A four stroke, single cylinder, spark ignition engine has been used for these experiments.

  1. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    Science.gov (United States)

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  2. Quality of Life Score as a Predictor of Death in Dogs with Degenerative Mitral Valve Disease.

    Science.gov (United States)

    Strunz, Célia M C; Marcondes-Santos, Mário; Takada, Julio Yoshio; Fragata, Fernanda S; Mansur, Antônio de Pádua

    2017-04-01

    The knowledge of the variables predicting mortality is important in clinical practice and for therapeutic monitoring in mitral valve disease. To determine whether a quality of life score evaluated with the Functional Evaluation of Cardiac Health questionnaire would predict mortality in dogs with degenerative mitral valve disease (DMVD). Thirty-six client-owned dogs with mitral valve disease underwent clinical, laboratory, and echocardiographic evaluations at baseline and were monitored for 6 months. Cardiovascular death was the primary outcome. The 36 dogs were classified as survivors or nonsurvivors. Higher values of the following variables were obtained at baseline in the nonsurviving group (12 dogs): amino-terminal pro-B-type natriuretic peptide (NT-proBNP) levels, plasma norepinephrine, heart rate, quality of life score, diastolic left ventricular internal dimension to aortic root ratio, systolic left ventricular internal dimension to aortic root ratio, and left atrium to aortic root ratio. NT-proBNP levels and quality life score were independently associated with death in the multivariable analysis. The quality life score was an independent variable for cardiac death in dogs with DMVD. This result is encouraging, as this score is easy to apply and does not require any technology, only a veterinarian and an observant owner. O conhecimento das variáveis preditoras de mortalidade é importante para a prática clínica e para o acompanhamento terapêutico na doença da valva mitral. Determinar se um escore de qualidade de vida avaliado com o Functional Evaluation of Cardiac Health poderia auxiliar na predição de mortalidade em cães com doença degenerativa da valva mitral (DDVM). Trinta e seis cães de estimação com doença valvar mitral foram submetidos a avaliação clínica, laboratorial e ecocardiográfica no início do estudo e monitorizados durante 6 meses. A morte cardiovascular foi o desfecho primário. Os 36 cães foram classificados como

  3. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  4. Relation of Aortic Valve and Coronary Artery Calcium in Patients With Chronic Kidney Disease to the Stage and Etiology of the Renal Disease

    NARCIS (Netherlands)

    Piers, Lieuwe H.; Touw, Hugo R. W.; Gansevoort, Ron; Franssen, Casper F. M.; Oudkerk, Matthijs; Zijlstra, Felix; Tio, Rene A.

    2009-01-01

    Patients with chronic renal failure have increased cardiac calcium loads. Previous studies have investigated the prevalence and quantitative extent of aortic valve calcium (AVC) and coronary artery calcium (CAC) in patients with various stages of chronic kidney disease (CKD). However, the impact of

  5. Early and mid-term results of autograft rescue by Ross reversal: A one-valve disease need not become a two-valve disease.

    Science.gov (United States)

    Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B

    2018-02-01

    Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Heart valve disease associated with treatment with ergot-derived dopamine agonists: a clinical and echocardiographic study of patients with Parkinson's disease

    DEFF Research Database (Denmark)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, E

    2007-01-01

    regurgitation (n = 5) was found in 22 EDDA patients (25.9%). Two patients had coexistent moderate mitral and tricuspid valvular regurgitation. Two non-EDDA patients had moderate valve insufficiency (3.8%, P insufficiency in the EDDA patients was 7....... Interventions. Patients were screened for valvular heart disease by clinical means and by examiner-blinded echocardiography. Main outcome measure was valvular regurgitation revealed by echocardiography. RESULTS: Severe aortic regurgitation (n = 4) or moderate aortic (n = 12), mitral (n = 3) or tricuspidal valve...

  7. Study of prognostic significance of antenatal ultrasonography and renin angiotensin system activation in predicting disease severity in posterior urethral valves

    Directory of Open Access Journals (Sweden)

    Divya Bhadoo

    2015-01-01

    Full Text Available Aims: Study on prognostic significance of antenatal ultrasonography and renin angiotensin system activation in predicting disease severity in posterior urethral valves. Materials and Methods: Antenatally diagnosed hydronephrosis patients were included. Postnatally, they were divided into two groups, posterior urethral valve (PUV and non-PUV. The studied parameters were: Gestational age at detection, surgical intervention, ultrasound findings, cord blood and follow up plasma renin activity (PRA values, vesico-ureteric reflux (VUR, renal scars, and glomerular filtration rate (GFR. Results: A total of 25 patients were included, 10 PUV and 15 non-PUV. All infants with PUV underwent primary valve incision. GFR was less than 60 ml/min/1.73 m 2 body surface area in 4 patients at last follow-up. Keyhole sign, oligoamnios, absent bladder cycling, and cortical cysts were not consistent findings on antenatal ultrasound in PUV. Cord blood PRA was significantly higher (P < 0.0001 in PUV compared to non-PUV patients. Gestational age at detection of hydronephrosis, cortical cysts, bladder wall thickness, and amniotic fluid index were not significantly correlated with GFR while PRA could differentiate between poor and better prognosis cases with PUV. Conclusions: Ultrasound was neither uniformly useful in diagnosing PUV antenatally, nor differentiating it from cases with non-PUV hydronephrosis. In congenital hydronephrosis, cord blood PRA was significantly higher in cases with PUV compared to non-PUV cases and fell significantly after valve ablation. Cord blood PRA could distinguish between poor and better prognosis cases with PUV.

  8. Relationship between aortic valve calcification and the severity of coronary atherosclerotic disease.

    Science.gov (United States)

    Qian, Juying; Chen, Zhangwei; Ge, Junbo; Ma, Jianying; Chang, Shufu; Fan, Bing; Liu, Xuebo; Ge, Lei

    2010-07-01

    Aortic valve calcification (AVC), which has been confirmed to be associated with various risk factors of cardiac disease, is common in the elderly and associated with increased cardiovascular mortality. It has been hypothesized that AVC is associated with coronary atherosclerotic disease, and its severity. Between July 2007 and November 2007, a total of 235 patients with chest pain or chest distress were admitted to the authors' institution for coronary angiography. The severity of coronary atherosclerotic disease (CAD) was evaluated by the Gensini score, the number of stenosed vessels, and the prevalence of total occlusion. All patients underwent transthoracic echocardiography to detect AVC. Patients with CAD had a higher prevalence of AVC than those without CAD (44% versus 26%, p = 0.005). Likewise, the prevalence of AVC was significantly higher in patients with a higher Gensini score than in those with a lower score. Patients with AVC had a higher prevalence of CAD, and higher Gensini scores and numbers of stenosed coronary arteries, even after stratification by age (65 years). On multivariable logistic regression analysis for CAD, the odds ratio (OR) of AVC was 2.315 (95% confidence interval (CI): 1.158-4.629, p = 0.018); this value was higher than that for total cholesterol (OR = 1.637, p = 0.008), lipoprotein-a (OR = 1.003, p = 0.015) and fibrinogen (OR = 1.009, p = 0.006), and marginally less than that for male gender (OR = 2.665, p = 0.005). Patients with AVC had a higher prevalence and greater severity of CAD.

  9. Comparison of biatrial and left atrial radiofrequency ablation in patients with heart valves diseases

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-прокофьев

    2015-10-01

    Full Text Available We analysed results of left atrial and biatrial anatomic scheme of radiofrequency (RF ablation of the atria in patients with valvular heart. From 2007 to 2011, RF ablation procedure performed 283 patients with atrial fibrillation and heart valve disease. Patients were divided into two groups - group I performed a complete circuit biatrial procedure (procedure maze IV - 131 patients, in group II only ablation of the left atrium -152 patients. Most of the patients had long-term persistent AF. The main problem of early postoperative period is dysfunction of pacemaker complex, which observed in 64.9% and 50.7% patients for group I and II, respectively (p = 0.031. Permanent dysfunction of pacemaker complex required implantation of permanent pacemaker (9.2% and 4.6% of cases for group I and II, respectively, p = 0,023. Predictors of dysfunction of the pacemaker complex were biatrial execution method and duration of AF. Freedom from AF and AT during 36 months after surgery was 80.4% for patients in group I and 78.5% for patients in group II, with no statistically significant difference (log-rank test, p = 0.621. Atrial transport function has not revealed that the active fraction of the right atrium was 29.8% higher than in group II in the early postoperative phase and by 17.9% in the long term, with no difference between groups for the left atrium has been received.

  10. An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve

    International Nuclear Information System (INIS)

    Qu, Minglu; Xia, Liang; Deng, Shiming; Jiang, Yiqiang

    2012-01-01

    Highlights: ► We experimentally studied the defrost performance under two EEV control strategies. ► The two EEV control strategies were fully open and controlled by a DS controller. ► When the EEV was under the DS controller, higher defrosting efficiency was obtained. -- Abstract: When an air source heat pump (ASHP) operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil. Frosting deteriorates the operation and energy efficiency of the ASHP and periodic defrosting becomes necessary. Currently the most widely used standard defrosting method for ASHPs is reverse cycle defrost. On the other hand, electronic expansion valves (EEVs) are commonly used in heat pump/refrigeration systems, including ASHP units, as throttle regulators of refrigerant flow. This paper reports on an experimental investigation of the performance of a reverse cycle defrost operation for a 6.5 kW experimental heating capacity residential ASHP whose outdoor coil had four-parallel refrigerant circuits, and with an EEV as the refrigerant flow throttle regulator. The detailed descriptions of the experimental ASHP unit and the experimental procedures of ASHP are firstly presented. This is followed by reporting the comparative experiments of two control strategies for the EEV to investigate their effects on defrosting performance: the EEV being fully open and the EEV being regulated by a degree of refrigerant superheat (DS) controller. Experimental results revealed that when the EEV was regulated by the DS controller during defrosting, a higher defrosting efficiency and less heat wastage would be resulted in.

  11. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    OpenAIRE

    Mustafa Zakkar; Mustafa Zakkar; Vito Domanico Bruno; Alexandru Ciprian Visan; Stephanie Curtis; Gianni Angelini; Emmanuel Lansac; Serban Stoica

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population...

  12. Abnormal antenatal sonogram: an indicator of disease severity in children with posterior urethral valves

    International Nuclear Information System (INIS)

    Harvie, S.; McLeod, L.; Acott, P.; Walsh, E.; Abdolell, M.; Macken, M.B.

    2009-01-01

    To review the association of an abnormal prenatal sonogram with most recent serum creatinine in patients with proven posterior urethral valves (PUV). Since 1992, all live-born patients between 1992-2004 with clinically proven PUV, with postnatally proven PUV, from 2 pediatric tertiary care centers, were reviewed for age at diagnosis, most recent serum creatinine, presence of chronic renal failure (CRF) (serum creatinine >2 standard deviations above normal for age), or end stage renal disease (dialysis or transplant). Available antenatal reports from the 2 centres and surrounding community hospitals were reviewed for gestational age (GA) at the time of ultrasound, volume of amniotic fluid, and urinary-tract abnormality. Thirty-four patients with proven PUV and prenatal sonograms were identified (1992-2004). Eighteen patients had abnormalities on their prenatal sonogram, with poor outcome in 5 (mean follow-up, 8 years [1-13 y]). No specific features were identified on prenatal sonogram. Sixteen patients had normal prenatal sonograms, with poor outcomes in 2 (mean follow-up, 8 years [3-13 y]). There is an increased risk of an abnormal serum creatinine among those patients with an abnormal prenatal study, odds ratio (OR) 2.6 (95% confidence interval, 0.35-32). PUV represents a spectrum of disease severity. A normal prenatal ultrasound does not preclude PUV. The majority of patients with a normal prenatal examination have good outcomes. The OR suggests that there may be increased risk for poor outcome in those with an abnormal prenatal examination. A multicenter study is necessary to obtain a larger sample size and more precise ORs. (author)

  13. Abnormal antenatal sonogram: an indicator of disease severity in children with posterior urethral valves

    Energy Technology Data Exchange (ETDEWEB)

    Harvie, S. [Peterborough Health Centre, Dept. of Radiology, Peterborough, Ontario (Canada); McLeod, L. [IWK Health Centre, Dept. of Obstetrics and Gynaecology, Halifax, Nova Scotia (Canada); Acott, P. [IWK Health Centre, Dept. of Nephrology, Halifax, Nova Scotia (Canada); Walsh, E. [Dr. Charles A. Janeway Children' s Health Centre, Dept. of Radiology, St. John' s, Newfoundland (Canada); Abdolell, M. [QE II Health Sciences Centre, Dept. of Radiology, Halifax, Nova Scotia (Canada); Macken, M.B., E-mail: mmacken@dal.ca [IWK Health Centre, Dept. of Diagnostic Imaging, Halifax, Nova Scotia (Canada)

    2009-10-15

    To review the association of an abnormal prenatal sonogram with most recent serum creatinine in patients with proven posterior urethral valves (PUV). Since 1992, all live-born patients between 1992-2004 with clinically proven PUV, with postnatally proven PUV, from 2 pediatric tertiary care centers, were reviewed for age at diagnosis, most recent serum creatinine, presence of chronic renal failure (CRF) (serum creatinine >2 standard deviations above normal for age), or end stage renal disease (dialysis or transplant). Available antenatal reports from the 2 centres and surrounding community hospitals were reviewed for gestational age (GA) at the time of ultrasound, volume of amniotic fluid, and urinary-tract abnormality. Thirty-four patients with proven PUV and prenatal sonograms were identified (1992-2004). Eighteen patients had abnormalities on their prenatal sonogram, with poor outcome in 5 (mean follow-up, 8 years [1-13 y]). No specific features were identified on prenatal sonogram. Sixteen patients had normal prenatal sonograms, with poor outcomes in 2 (mean follow-up, 8 years [3-13 y]). There is an increased risk of an abnormal serum creatinine among those patients with an abnormal prenatal study, odds ratio (OR) 2.6 (95% confidence interval, 0.35-32). PUV represents a spectrum of disease severity. A normal prenatal ultrasound does not preclude PUV. The majority of patients with a normal prenatal examination have good outcomes. The OR suggests that there may be increased risk for poor outcome in those with an abnormal prenatal examination. A multicenter study is necessary to obtain a larger sample size and more precise ORs. (author)

  14. Pulmonary valve stenosis

    Science.gov (United States)

    ... surgery - discharge Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  15. The papillary muscles as shock absorbers of the mitral valve complex. An experimental study.

    Science.gov (United States)

    Joudinaud, Thomas M; Kegel, Corrine L; Flecher, Erwan M; Weber, Patricia A; Lansac, Emmanuel; Hvass, Ulrich; Duran, Carlos M G

    2007-07-01

    Although it is known that the papillary muscles ensure the continuity between the left ventricle (LV) and the mitral apparatus, their precise mechanism needs further study. We hypothesize that the papillary muscles function as shock absorbers to maintain a constant distance between their tips and the mitral annulus during the entire cardiac cycle. Sonomicrometry crystals were implanted in five sheep in the mitral annulus at the trigones (T1 and T2), mid anterior annulus (AA) mid posterior annulus (PA), base of the posterior lateral scallops (P1 and P2), tips of papillary muscles (M1 and M2), and LV apex. LV and aortic pressures were simultaneously recorded and used to define the different phases of the cardiac cycle. No significant distance changes were found during the cardiac cycle between each papillary muscle tip and their corresponding mitral hemi-annulus: M1-T1, (3.5+/-2%); M1-P1 (5+/-2%); M1-PA (5+/-3%); M2-T2 (2.7+/-2%); M2-P2 (6.1+/-3%); and M2-AA (4.2+/-3%); (p>0.05, ANOVA). Significant changes were observed in distances between each papillary muscle tip and the contralateral hemi-mitral annulus: M1-T2 (1.7+/-3%); M1-P2 (23+/-6%); M1-AA (6+/-3%); M2-T1 (8+/-3%); M2-P1 (10.5+/-6%); and M2-PA (12.6+/-8%); (pshock absorbers to maintain the basic mitral valve geometry constant during the cardiac cycle.

  16. Experimental models of autoimmune inflammatory ocular diseases

    Directory of Open Access Journals (Sweden)

    Fabio Gasparin

    2012-04-01

    Full Text Available Ocular inflammation is one of the leading causes of blindness and loss of vision. Human uveitis is a complex and heterogeneous group of diseases characterized by inflammation of intraocular tissues. The eye may be the only organ involved, or uveitis may be part of a systemic disease. A significant number of cases are of unknown etiology and are labeled idiopathic. Animal models have been developed to the study of the physiopathogenesis of autoimmune uveitis due to the difficulty in obtaining human eye inflamed tissues for experiments. Most of those models are induced by injection of specific photoreceptors proteins (e.g., S-antigen, interphotoreceptor retinoid-binding protein, rhodopsin, recoverin, phosducin. Non-retinal antigens, including melanin-associated proteins and myelin basic protein, are also good inducers of uveitis in animals. Understanding the basic mechanisms and pathogenesis of autoimmune ocular diseases are essential for the development of new treatment approaches and therapeutic agents. The present review describes the main experimental models of autoimmune ocular inflammatory diseases.

  17. Disappearance of electrocardiographic abnormalities associated with the arrhythmic pattern of a Barlow disease after surgical mitral valve repair

    Directory of Open Access Journals (Sweden)

    Matteo Augello

    2017-04-01

    Full Text Available We describe the case of a 46-year old female with a Barlow’s disease (MVP characterized by systolic curling of posterior left ventricular (LV wall + significant mitral annular disjunction + complex ventricular arrhythmias + syncope + inverted T waves in inferolateral leads in whom a successful surgical mitral valve rapair determined the disappearance not only of the echocardiographic but also the electrocardiographic abnormalities (in particular the inferolateral T waves inversion on basal electrocardiogram and the complex basal arrhythmic pattern. This case demonstrates that electrocardiographic abnormalities may disappear after the surgical correction of the mechanical stretch imposed on the inferior LV free wall by the prolapsing mitral valve leaflets. Electrocardiographic changes remain an important and easy marker to recognize for the identification of a high-risk subgroup of MVP patients.

  18. Brain-natriuretic peptide and cyclic guanosine monophosphate as biomarkers of myxomatous mitral valve disease in dogs

    DEFF Research Database (Denmark)

    Moesgaard, Sophia Gry; Falk, Bo Torkel; Teerlink, Tom

    2011-01-01

    Elevations in the plasma concentrations of natriuretic peptides correlate with increased severity of myxomatous mitral valve disease (MMVD) in dogs. This study correlates the severity of MMVD with the plasma concentrations of the biomarkers N-terminal fragment of the pro-brain-natriuretic peptide...... (NT-proBNP) and its second messenger, cyclic guanosine monophosphate (cGMP). Furthermore, the l-arginine:asymmetric dimethylarginine (ADMA) ratio was measured as an index of nitric oxide availability. The study included 75 dogs sub-divided into five groups based on severity of MMVD as assessed...... by clinical examination and echocardiography. Plasma NT-proBNP and cGMP concentrations increased with increasing valve dysfunction and were significantly elevated in dogs with heart failure. The cGMP:NT-proBNP ratio decreased significantly in dogs with heart failure, suggesting the development of natriuretic...

  19. The Burden of Pulmonary Hypertension in Patients with Degenerative Mitral Valve Disease in Enugu South-East Nigeria: An Echocardiographic Based Study.

    Science.gov (United States)

    Ejim, E C; Oguanobi, N I

    2016-01-01

    Pulmonary hypertension is a common complication of degenerative mitral valve disease, and contributes significantly to both morbidity and mortality. The use of medications for reduction of pulmonary pressure in patients is not a common practice by most physicians in this part of the world because of the absence of data on pulmonary hypertension. The authors set out to find the prevalence of pulmonary hypertension in patients with degenerative mitral valve disease and to determine if there are gender differences in affectation. This will form a basis for future research on the management of pulmonary hypertension in sub-Saharan Africa. The echocardiographic records of 1390 patients carried out over a period of 4 years were retrospectively reviewed. The examinations were done with a Logic 500 MD echocardiographic machine. Tricuspid valve regurgitation velocity above 250 cm/s defined pulmonary hypertension. Data obtained included presence of degenerative mitral valve disease, pulmonary hypertension, age, and gender. A total of 1390 echocardiogram reports done at Conquest Medical Imaging, Enugu, from July 2009 to August 2013 were retrospectively reviewed. Degenerative mitral valve disease was noted in 18.7% of the patients, (259/1390) made up of 149 males and 110 females with a mean age of 68.3 (14.4) years. Pulmonary hypertension was present in 30% of the patients (78/259) and affected males more than females. Pulmonary hypertension is common in patients with degenerative mitral valve disease in Enugu, and affects males more than females.

  20. Prevalence and severity of coronary artery disease in diabetic patients with aortic valve calcification.

    Science.gov (United States)

    Chen, Zhang-wei; Qian, Ju-ying; Jian, Ying; Ge, Lei; Liu, Xue-bo; Shu, Xian-hong; Ge, Junbo

    2011-02-01

    Aortic valve calcification (AVC) is common in the elderly and associated with increased cardiovascular mortality, while diabetes is one of the confirmed risk factors for coronary artery disease (CAD). In this study, we aimed to evaluate the prevalence and severity of CAD in type-2 diabetic patients with AVC. From June to December in 2007, a total of 325 consecutive patients with chest pain or chest distress were admitted for coronary angiography. The severity of CAD was evaluated by the Gensini score and the number of stenosed vessels. All patients underwent transthoracic echocardiography for detecting AVC. Compared with the patients without diabetes (n = 221), the type-2 diabetic patients (n = 104) had a similar prevalence of CAD (66.5% vs. 72.1%, P = 0.312). Further classified by the presence of AVC, patients with AVC had a higher prevalence of CAD, average Gensini score and the number of stenosed vessels, both in the group with and without diabetes. It was also demonstrated that the odds ratio (OR) of AVC for CAD in the diabetic patients was higher than in the non-diabetic ones (3.405 vs 2.515) after chi-square analysis (single-variable). However, at multivariable logistic regression analysis for CAD, the OR of AVC was 3.757 (P = 0.03) in diabetic group, while it did not achieve statistical significance in the non-diabetic group (OR = 2.130, P= 0.074). Type-2 diabetic patients with AVC had a higher prevalence of and more severe CAD.

  1. Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Satana, Banu; Yalvac, Ilgaz S; Sungur, Gulten; Eksioglu, Umit; Basarir, Berna; Altan, Cigdem; Duman, Sunay

    2015-01-01

    To evaluate outcomes of patients with uveitic glaucoma secondary to Behçet disease (BD) who underwent Ahmed glaucoma valve (AGV) implantation. A retrospective chart review of 14 eyes of 10 patients with uveitic glaucoma associated with BD who underwent AGV implantation at a tertiary referral center. Treatment success was defined as intraocular pressure (IOP) between 6 and 21 mm Hg with or without antiglaucoma medication, without further additional glaucoma surgery or loss of light perception. The main outcome measures were IOP, best-corrected visual acuity measured with Snellen charts, and number of glaucoma medications. Mean duration of postoperative follow-up was 18.2±6.6 months (range, 6 to 31 mo). Of the 14 eyes, 10 (71.4%) were pseudophakic and 5 (35.7%) had primary AGV implantation without a history of previous glaucoma surgery. At the most recent follow-up visit, 13 of the 14 eyes had an IOP between 6 and 21 mm Hg. Mean IOP was significantly reduced during follow-up, as compared with preoperative values (P≤0.005). The cumulative probability of surgical success rate was 90.9% at 18 months based on Kaplan-Meier survival analysis. The mean number of antiglaucoma medications required to achieve the desired IOP decreased from 3.4±0.5 preoperatively to 1.0±1.1 postoperatively (P≤0.05). Visual acuity loss of >2 lines occurred in 4 eyes (28.5%) due to optic atrophy associated with retinal vasculitis. Temporary hypotony developed during follow-up in 4 eyes (28.5%) at first postoperative week. For the management of uveitic glaucoma associated with BD, AGV implantation is a successful method for glaucoma control but requires additional surgical interventions for high early hypotony rates.

  2. Impacts of endoscopic gastroesophageal flap valve grading on pediatric gastroesophageal reflux disease.

    Directory of Open Access Journals (Sweden)

    Kai-Chi Chang

    Full Text Available Gastroesophageal flap valve (GEFV endoscopic grading is reported to be associated with gastroesophageal reflux disease (GERD in adults; however its role in pediatric groups remains unknown. This study aimed to investigate the significance of GEFV grading and the associations to multichannel intraluminal impedance and pH monitoring (MII-pH in children with GERD.A total of 48 children with GERD symptoms who received esophagogastroduodenoscopy and MII-pH monitoring were enrolled. The degree of GEFV was graded from I to IV according to the Hill classification, and classified into two groups: normal GEFV (Hill grades I and II, and abnormal GEFV (Hill grades III and VI. Endoscopic findings and MII-pH monitoring were analyzed among the groups.Thirty-six patients had normal GEFV while 12 had abnormal GEFV. The presence of erosive esophagitis was significantly more common in the patients with abnormal GEFV (p = 0.037, OR 9.84, 95% CI 1.15-84.42. Pathological acidic gastroesophageal reflux (GER determined by MII-pH was more prevalent in the patients with loosened GEFV geometry (p = 0.01, OR 7.0, 95% CI 1.67-27.38. There were significant positive correlations between GEFV Hill grading I to IV and the severity of erosive esophagitis (r = 0.49, p<0.001, percentage of supine acid reflux (r = 0.37, p = 0.009, percentage of total acid reflux (r = 0.3284, p = 0.023, and DeMeester score (r = 0.36, p = 0.01 detected by pH monitoring. In the impedance study, GEFV Hill grading also positively correlated to median number of acid reflux events (r = 0.3015, p = 0.037.GEFV dysfunction highly associated with acid GER and severe erosive esophagitis. An abnormal GEFV is a sign of acid GER in children.

  3. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  4. Serum magnesium, phosphorus, and calcium levels and subclinical calcific aortic valve disease: A population-based study.

    Science.gov (United States)

    Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu

    2018-06-01

    Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Experimental Validation of Mathematical Framework for Fast Switching Valves used in Digital Hydraulic Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Roemer, Daniel Beck; Bech, Michael Møller

    2015-01-01

    of 10 kW during switching (mean of approximately 250 W) and a pressure loss below 0.5 bar at 600 l/min. The main goal of this article is validate parts of the mathematical framework based on a series of experiments. Furthermore, this article aims to document the experience gained from the experimental...

  6. Correction of moderate secondary mitral regurgitation due to aortic valve disease: immediate results

    Directory of Open Access Journals (Sweden)

    В. М. Назаров

    2015-10-01

    Full Text Available To evaluate the impact of surgical strategy in concomitant mitral valve surgery or isolated aortic valve replacement (AVR in patients with moderate secondary mitral regurgitation (MR, 1 574 patients underwent AVR over a period from January 2003 to December 2011. 241 patients had secondary MR 2+ and constituted the study population. Patients were stratified into two groups, those without concomitant mitral valve surgery (Group A, n = 113 and with it (Group B, n = 128. It was found out that AVR plastic correction of MI reduces its recurrence during short-term follow-up but increases the intervention time leading to an insignificant rise in lethality. In patients with aortic stenosis the age exceeding 70 years and the presence of atrial fibrillation are found to be the most significant predictors of preservation of residual mitral regurgitation in the early postoperative period, while more indicative for patients with aortic insufficiency is the presence of tricuspid regurgitation grade 2 or higher.

  7. Idiopathic mitral valve disease in a patient presenting with Axenfeld-Rieger syndrome.

    Science.gov (United States)

    Antevil, Jared; Umakanthan, Ramanan; Leacche, Marzia; Brewer, Zachary; Solenkova, Natalia; Byrne, John G; Greelish, James P

    2009-05-01

    A 33-year-old, previously healthy male presented with respiratory distress and underwent intubation. A physical examination revealed a holosystolic murmur and pupillary abnormalities. Echocardiography revealed a flail anterior mitral valve leaflet with ruptured chordae and severe mitral regurgitation. The patient underwent urgent mitral valve replacement and tolerated the procedure well. The mitral valve leaflet was myxomatous and calcified -- an unusual find in such a patient. An ophthalmology consultation was obtained and the patient diagnosed with Axenfeld-Rieger syndrome, a disorder of the anterior ocular chamber that has been associated with cardiac malformations. The present case report adds to the body of literature which suggests a correlation between Axenfeld-Rieger syndrome and valvular abnormalities. Hence, it is believed prudent that patients with Axenfeld-Rieger syndrome should undergo echocardiographic screenings for valvular abnormalities.

  8. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  9. Valvular heart disease: assessment of valve morphology and quantification using MR

    Energy Technology Data Exchange (ETDEWEB)

    Schwitter, J. [Div. of Cardiology and Cardiovascular, MR Center, Univ. Hospital Zurich (Switzerland)

    2000-06-01

    For clinical evaluation and decision-making in patients with valvular heart disease, the diagnostic armamentarium expands steadily. This evolution makes it difficult to choose the most appropriate approach for a specific valvular lesion. It may also reflect our uncertainty of what are the findings that best predict clinical outcome of patients, e. g. after surgery. Accordingly, for each type of valvular lesion, some pathophysiological considerations are stated in order to derive the most important measures that would allow optimal guidance of patients. Based on these considerations the value of an MR study is discussed for each valvular lesion. Newest advances in MR technology allow for highly accurate measurements of regurgitant volumes and hence, MR may be the method of choice for a quantitative evaluation of regurgitant valves. For assessment of stenosis severity, measurement of transvalvular pressure gradient is an appropriate measure and MR may not confer benefits over echocardiography, provided the ultrasound window is adequate (and stroke volume is in the normal range). With respect to surgical treatment, valvular morphology is of pivotal importance, particularly for the mitral valve, and echocardiography still appears to be the first line method. Little data relate lesion severity and/or morphology to clinical outcome. Conversely, the extent of cardiac adaptation to pressure- and/or volume-overload, i. e. ventricular remodeling, is a strong predictor of outcome, and is therefore most important for final judgement of the patient. For assessment of left and right ventricular remodeling, echocardiography typically provides all the necessary information. However, in special cases with discrepant findings, with inadequate ultrasound window, or in the preoperative work-up, MR may provide important information regarding cardiac adaptation to valvular lesion. (orig.) [German] Das diagnostische Repertoire zur Evaluation von Klappenvitien ist in den letzten Jahren

  10. A New Experimental Device for Transapical Access of the Aortic and Mitral Valves as well as the Aorta in its Various Segments

    Directory of Open Access Journals (Sweden)

    Leonardo Paim

    Full Text Available Abstract Objective: To present the results of a new experimental device developed to facilitate the transapical access in endovascular treatment of structural heart diseases. It aims to reduce the risk of bleeding and complications in this type of access and demonstrate the device as a safe, fast and effective alternative. Methods: CorPoint is composed of three parts: introducer, base with coiled spring, and closing capsule. By rotating movements, the spring is introduced into the myocardium and progressively approaches the base to the surface of the heart. Guidewires and catheters are inserted through the hollow central part and, at the end of the procedure, the capsule is screwed over the base, therefore stopping any bleeding. Results: The device was implanted in 15 pigs, weighing 60 kg each, through an anterolateral thoracotomy, while catheters were introduced and guided by fluoroscopy. All animals had minimal bleeding; introducers with diameter up to 22 Fr were used and various catheters and guidewires were easily handled. After finishing the procedure, the closing capsule was attached and no bleeding was observed at the site. Conclusion: This new device has proved effective, fast and secure for the transapical access. This shows great potential for use, especially by ensuring an easier and direct access to the mitral and aortic valves; the shortest distance to be traveled by catheters; access to the ascending and descending aorta; decreased bleeding complications; decreased surgical time; and the possibility of allowing the technique to evolve and become totally percutaneous.

  11. Endostatin and osteopontin are elevated in patients with both coronary artery disease and aortic valve calcification

    Directory of Open Access Journals (Sweden)

    Michael Sponder

    2015-12-01

    Conclusions: This is the first study showing an association of ES with AVC in CAD-patients independent from age, BMI and CAD-severity which seems to be of distinct interest when trying to understand the process of heart valve calcification. OPN also correlates with AVC-severity but is mostly dependent on the age of the patients.

  12. Arteriosclerotic changes in the myocardium, lung, and kidney in dogs with chronic congestive heart failure and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Falk, Bo Torkel; Jönsson, Lennart; Olsen, Lisbeth Høier

    2006-01-01

    Background: The occurrence of small vessel arteriosclerosis in the myocardium, kidney, and lung in dogs with naturally occurring myxomatous mitral valve disease has not been previously investigated systematically. Methods: Twenty-one dogs with naturally occurring congestive heart failure and 21 age......-matched, sex-matched, and weight-matched control dogs underwent extensive pathological and histopathological examination. Morphometry and scoring of tissue sections were used to measure arterial narrowing and fibrosis in the myocardium, kidney, and lung; and intimal thickness and plaque formation in the aorta...... and pulmonary artery. Results: Dogs with congestive heart failure had significantly more arterial narrowing in the left ventricle (Pdogs. However...

  13. The Impact of Obesity on Postoperative Outcomes in Adults with Congenital Heart Disease Undergoing Pulmonary Valve Replacement.

    Science.gov (United States)

    Buelow, Matthew W; Earing, Michael G; Hill, Garick D; Cohen, Scott B; Bartz, Peter J; Tweddell, James S; Ginde, Salil

    2015-01-01

    The impact of obesity on surgical morbidity in adults with congenital heart disease is currently unknown. The aim of our study was to investigate the impact of obesity on postoperative outcomes in adults with congenital heart disease undergoing reoperation for pulmonary valve replacement. A retrospective analysis was performed assessing the influence of obesity on surgical outcomes. Obesity was defined as a body mass index ≥30 kg/m2. The mean body mass index of the cohort was 25.9 ± 6.9 kg/m2 . The cohort included 71 patients with 17 patients (24%) being obese. There was no postoperative mortality. Obese patients had a longer hospital length of stay (6.6 vs. 4.7 days; P obesity was independently associated with hospital length of stay >5 days (odds ratio [OR] = 5.2; 95% confidence interval [CI]: 1.5-18.2, P = .01) and with increased postoperative arrhythmias (OR = 4.2; 95% CI: 1.7-40, P Obesity is associated with increased morbidity in adults with congenital heart disease undergoing pulmonary valve replacement, including longer hospitalization and higher risk for postoperative arrhythmias. © 2015 Wiley Periodicals, Inc.

  14. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  15. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  16. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  17. Cardiogenic shock as a complication of acute mitral valve regurgitation following posteromedial papillary muscle infarction in the absence of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Frati Giacomo

    2008-11-01

    Full Text Available Abstract A 48 year old man was transferred to our department with cardiogenic shock, pyrexia, a high white cell count and significant serum troponin T level. Clinical evaluation revealed severe mitral regurgitation secondary to a flail of both mitral valve leaflets. An emergency cardiac catheterisation did not reveal any significant coronary artery disease. Left ventricular angiogram and echocardiography demonstrated a good left ventricular function and massive mitral regurgitation. Blood cultures were negative for aerobics, anaerobics and fungi. The patient underwent emergency mitral valve replacement with a mechanical valve. Intraoperatively, the posteromedial papillary muscle was found to be ruptured. Histology of the papillary muscle revealed myocardial necrosis with no signs of infection. Cultures obtained from a mitral valve specimen were negative. The patient's recovery was uneventful and he was discharged on the 6th postoperative day.

  18. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  19. Catheterization Laboratory: Structural Heart Disease, Devices, and Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Fiorilli, Paul N; Anwaruddin, Saif; Zhou, Elizabeth; Shah, Ronak

    2017-12-01

    The cardiac catheterization laboratory is advancing medicine by performing procedures on patients who would usually require sternotomy and cardiopulmonary bypass. These procedures are done percutaneously, allowing them to be performed on patients considered inoperable. Patients have compromised cardiovascular function or advanced age. An anesthesiologist is essential for these procedures in case of hemodynamic compromise. Interventionalists are becoming more familiar with transcatheter aortic valve replacement and the device has become smaller, both contributing to less complications. Left atrial occlusion and the endovascular edge-to-edge mitral valve repair devices were approved. Although these devices require general anesthesia, an invasive surgery and cardiopulmonary bypass machine are not necessary for deployment. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Learning discriminative distance functions for valve retrieval and improved decision support in valvular heart disease

    Science.gov (United States)

    Voigt, Ingmar; Vitanovski, Dime; Ionasec, Razvan I.; Tsymal, Alexey; Georgescu, Bogdan; Zhou, Shaohua K.; Huber, Martin; Navab, Nassir; Hornegger, Joachim; Comaniciu, Dorin

    2010-03-01

    Disorders of the heart valves constitute a considerable health problem and often require surgical intervention. Recently various approaches were published seeking to overcome the shortcomings of current clinical practice,that still relies on manually performed measurements for performance assessment. Clinical decisions are still based on generic information from clinical guidelines and publications and personal experience of clinicians. We present a framework for retrieval and decision support using learning based discriminative distance functions and visualization of patient similarity with relative neighborhood graphsbased on shape and derived features. We considered two learning based techniques, namely learning from equivalence constraints and the intrinsic Random Forest distance. The generic approach enables for learning arbitrary user-defined concepts of similarity depending on the application. This is demonstrated with the proposed applications, including automated diagnosis and interventional suitability classification, where classification rates of up to 88.9% and 85.9% could be observed on a set of valve models from 288 and 102 patients respectively.

  1. Management of tricuspid valve regurgitation: Position statement of the European Society of Cardiology Working Groups of Cardiovascular Surgery and Valvular Heart Disease.

    Science.gov (United States)

    Antunes, Manuel J; Rodríguez-Palomares, José; Prendergast, Bernard; De Bonis, Michele; Rosenhek, Raphael; Al-Attar, Nawwar; Barili, Fabio; Casselman, Filip; Folliguet, Thierry; Iung, Bernard; Lancellotti, Patrizio; Muneretto, Claudio; Obadia, Jean-François; Pierard, Luc; Suwalski, Piotr; Zamorano, Pepe

    2017-12-01

    Tricuspid regurgitation (TR) is a very frequent manifestation of valvular heart disease. It may be due to the primary involvement of the valve or secondary to pulmonary hypertension or to the left-sided heart valve disease (most commonly rheumatic and involving the mitral valve). The pathophysiology of secondary TR is complex and is intrinsically connected to the anatomy and function of the right ventricle. A systematic multimodality approach to diagnosis and assessment (based not only on the severity of the TR but also on the assessment of annular size, RV function and degree of pulmonary hypertension) is, therefore, essential. Once considered non-important, treatment of secondary TR is currently viewed as an essential concomitant procedure at the time of mitral (and, less frequently, aortic valve) surgery. Although the indications for surgical management of severe TR are now generally accepted (Class I), controversy persists concerning the role of intervention for moderate TR. However, there is a trend for intervention in this setting, especially at the time of surgery for left-sided heart valve disease and/or in patients with significant tricuspid annular dilatation (Class IIa). Currently, surgery remains the best approach for the interventional treatment of TR. Percutaneous tricuspid valve intervention (both repair and replacement) is still in its infancy but may become a reliable option in future, especially for high-risk patients with isolated primary TR or with secondary TR related to advanced left-sided heart valve disease. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    Science.gov (United States)

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  3. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  4. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  5. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  6. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  7. Quantification of Mitral Regurgitation in Anatolian Shepherd Dogs with Asymptomatic Degenerative Mitral Valve Disease

    Directory of Open Access Journals (Sweden)

    Kursad Turgut1*, Yilmaz Koc2, Hasan Guzelbektes1,3, Amir Naseri1, Mehmet Ege Ince1 and Ismail Sen1

    2016-11-01

    Full Text Available Degenerative mitral valvular disease (DMVD is the most frequent cardiac disease, causing mitral regurgitation (MR in dogs. The purpose of this study was to compare the ratio of the regurgitant jet area (RJA to the left atrial area (LAA (RJA/LAA with subtracting method to quantify regurgitant volume (RegV and regurgitant fraction (RF in asymptomatic Anatolian Shepherd Dogs (ASHs with DMVD. Thirty-eight ASHs with DMVD were used as experimental group. The control group consisted of 35 healthy ASHs. In 38 ASHs with DMVD (20 B1 dogs and 18 B2 dogs, the severity of MR was assessed by RJA/LAA and subtraction method. No differences were noted between the assays measuring the severity of MR by χ2 analysis. The observed agreement between the assays was 81% for RJA/LAA vs RegV and was 73% for RJA/LAA vs RF, and the kappa statistic values for RJA/LAA vs RegV and for RJA/LAA vs RF were 0.63 (substantial agreement and 0.50 (moderate agreement, respectively. Our results indicate that each quantification method was valuable to estimate the acuteness of the disease in ASHs with MR and all were in good accordance with the echocardiographic heart size and N-terminal Pro-Brain Natriuretic Peptide (NT-proBNP measurements. Therefore, the each of these non-invasive methods may be functional to serially estimate the acuteness of MR in DMVD in order to monitor the progression of disease. Future studies have to evaluate, if these will be useful to anticipate the risk or time of decompensation in asymptomatic dogs.

  8. Increased serum C-reactive protein concentrations in dogs with congestive heart failure due to myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Ljungvall, I.; Hillstrom, A.

    2016-01-01

    Cardiovascular disease in humans and dogs is associated with mildly increased circulating concentrations of C-reactive protein (CRP). Few studies have evaluated associations between circulating CRP and canine myxomatous mitral valve disease (MMVD) and the results reported have been divergent....... The aim of this study was to investigate whether serum concentrations of CRP, determined using a novel automated canine-specific high -sensitivity CRP assay (Gentian hsCRP), were associated with severity of MMVD and selected clinical variables in dogs. The study included 188 client-owned dogs...... with different severities of MMVD. Dogs were classified based on ACVIM consensus statement guidelines (group A, n = 58; group BI, n = 56; group B2, n = 38; group C, n = 36). Data were analysed using descriptive statistics and multiple regression analysis. Dogs with congestive heart failure (CHF; group C) had...

  9. Determination of flow-rate characteristics and parameters of piezo pilot valves

    Directory of Open Access Journals (Sweden)

    Takosoglu Jakub

    2017-01-01

    Full Text Available Pneumatic directional valves are used in most industrial pneumatic systems. Most of them are two-stage valves controlled by a pilot valve. Pilot valves are often chosen randomly. Experimental studies in order to determine the flow-rate characteristics and parameters of pilot valves were not conducted. The paper presents experimental research of two piezo pilot valves.

  10. Simulation and Experimental Testing of an Actuator for a Fast Switching On-Off Valve Suitable to Efficient Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Bech, Michael Møller

    2014-01-01

    Digital Displacement (DD) fluid power machines are upcoming technology, improving the efficiency compared to traditional variable displacement machines, especially at low displacements where currently available fluid power pumps/motors suffer from mediocre efficiency. This efficiency improvement...... is made possible using independent electronically controlled seat valves for each pressure chamber, which is controlled corresponding to the rotation of the crankshaft. By control of these pressure chamber seat valves, the total displacement are controlled in discrete steps, and the pressure chambers...... not contributing to the displacement are not pressurized, which has been shown to improve the efficiency. To make this type of displacement control possible and energy efficient, the seat valves must be fast switching (ms range) and exhibit a very low pressure loss during operation, setting strict requirements...

  11. An Experimental Study of Emission and Combustion Characteristics of Marine Diesel Engine in Case of Cylinder Valves Leakage

    Directory of Open Access Journals (Sweden)

    Kowalski Jerzy

    2015-09-01

    Full Text Available Presented paper shows the results of the laboratory tests on the relationship between throttling of both air intake duct and exhaust gas duct and a gaseous emission from the marine engine. The object of research is a laboratory, four-stroke, DI diesel engine, operated at loads from 50 kW to 250 kW at a constant speed equal to 750 rpm. During the laboratory tests over 50 parameters of the engine were measured with its technical condition recognized as a „working properly” and with simulated leakage of both air intake valve and exhaust gas valve on the second cylinder. The results of this laboratory research confirm that the leakage of cylinder valves causes no significant changes of the thermodynamic parameters of the engine. Simulated leakages through the inlet and exhaust valve caused a significant increase in fuel consumption of the engine. Valve leakages cause an increase of the exhaust gas temperature behind the cylinder with leakage and behind other cylinders. The exhaust gas temperature increase is relatively small and clearly visible only at low loads of the engine. The increase of the temperature and pressure of the charging air behind the intercooler were observed too. Charging air temperature is significantly higher during the engine operation with inlet valve leakage. The study results show significant increases of the CO, NOx and CO2 emission for all the mentioned malfunctions. The conclusion is that the results of measurements of the composition of the exhaust gas may contain valuable diagnostic information about the technical condition of the air intake duct and the exhaust gas duct of the marine engine.

  12. Coanda effect in valves

    Directory of Open Access Journals (Sweden)

    Uruba Václav

    2017-01-01

    Full Text Available Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.

  13. Long-Term Health Benefit of Transcatheter Aortic Valve Replacement in Patients With Chronic Lung Disease.

    Science.gov (United States)

    Crestanello, Juan A; Popma, Jeffrey J; Adams, David H; Deeb, G Michael; Mumtaz, Mubashir; George, Barry; Huang, Jian; Reardon, Michael J

    2017-11-27

    This study sought to characterize the long-term effect of chronic lung disease (CLD) on mortality, clinical outcomes, quality of life, and health benefits after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis. The long-term effect of CLD after TAVR is unknown. Prevalence and severity of CLD was determined at baseline in high- and extreme-risk patients with aortic stenosis from the CoreValve US Pivotal Trial. Clinical outcomes and health status were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS). A favorable health benefit was defined as alive with a KCCQ-OS ≥60 and stability (CLD was present in 55% (20% mild, 13% moderate, 22% severe) of the 1,030 patients studied. All-cause mortality was higher in patients with moderate and severe CLD at 1 year (19.6% mild, 28.1% moderate, 26.9% severe CLD vs. 19.2% non-CLD; p = 0.030) and 3 years (44.8% mild, 53.0% moderate, 51.9% severe vs. 37.7% non-CLD; p CLD at 1 and 3 years. All patients had a nearly 20-point improvement in KCCQ-OS at 1 and 3 years. However, only 43.3% of patients with CLD had a favorable health benefit at 1 year and 22.5% at 3 years. Moderate and severe CLD increases 1- and 3-year mortality after TAVR. Although functional status and quality of life were improved in CLD at 1 and 3 years after TAVR, a favorable health benefit was only achieved in selected patients. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. A comparison of the histopathologic pattern of the left atrium in canine dilated cardiomyopathy and chronic mitral valve disease.

    Science.gov (United States)

    Janus, Izabela; Noszczyk-Nowak, Agnieszka; Nowak, Marcin; Ciaputa, Rafał; Kandefer-Gola, Małgorzata; Pasławska, Urszula

    2016-01-05

    Dilated cardiomyopathy (DCM) and chronic mitral valve disease (CMVD) in dogs are associated with heart chamber enlargement, also of the left atrium. DCM is often accompanied by rhythm disturbances (mainly atrial fibrillation or ventricular arrhythmias). In CMVD, arrhythmias are observed less frequently. It is still unclear whether left atrial enlargement in these diseases results from volume overload or if it is also connected with other factors (e.g. rhythm disturbances). This study was conducted on the left atrial myocardial specimens from 31 dogs, including those from 16 dogs with clinically diagnosed DCM and 15 dogs with CMVD. After fixation and staining (using haematoxylin-eosin and Masson-Goldner trichrome stain), the specimens underwent evaluation. Parenchymal changes (fibrosis, fatty infiltration, and vessel narrowing), degenerative changes (loss of striation, changes in cardiomyocyte structure, and abnormal cell nuclei) and the presence of inflammatory infiltrates were assessed. More interstitial fibrosis (median 4 vs. 2.5 grid fields; p < 0.05) and less perivascular fibrosis (median score 1 vs. 2; p < 0.05) was observed in the DCM group compared to the CMVD group. Moreover, less distinct vessel narrowing was observed in the DCM group than in the CMVD group (median lumen area ratio 0.3 vs. 0.26 respectively; p < 0.05). Dogs with DCM showed more strongly defined degenerative changes than the CMVD dogs (median nuclei enlargement score 3 vs. 1, median loss of striation score 3 vs. 2 and median structural alterations score 3 vs. 2, respectively; p < 0.05). The obtained results indicate a different nature of changes occurring in the left atrial myocardium of dogs with DCM compared to dogs with mitral valve disease, including differences in vessel narrowing, cardiomyocyte degeneration and in the distribution of connective tissue.

  15. Porcine Tricuspid Valve Anatomy and Human Compatibility: Relevance for Preclinical Validation of Novel Valve Interventions.

    Science.gov (United States)

    Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John

    2016-09-01

    Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p human hearts.

  16. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  17. Nonalcoholic fatty liver disease is associated with aortic valve sclerosis in patients with type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Stefano Bonapace

    Full Text Available BACKGROUND: Recent epidemiological data suggest that non-alcoholic fatty liver disease (NAFLD is closely associated with aortic valve sclerosis (AVS, an emerging risk factor for adverse cardiovascular outcomes, in nondiabetic and type 2 diabetic individuals. To date, nobody has investigated the association between NAFLD and AVS in people with type 2 diabetes, a group of individuals in which the prevalence of these two diseases is high. METHODS AND RESULTS: We recruited 180 consecutive type 2 diabetic patients without ischemic heart disease, valvular heart disease, hepatic diseases or excessive alcohol consumption. NAFLD was diagnosed by liver ultrasonography whereas AVS was determined by conventional echocardiography in all participants. In the whole sample, 120 (66.7% patients had NAFLD and 53 (29.4% had AVS. No patients had aortic stenosis. NAFLD was strongly associated with an increased risk of prevalent AVS (odds ratio [OR] 2.79, 95% CI 1.3-6.1, p<0.01. Adjustments for age, sex, duration of diabetes, diabetes treatment, body mass index, smoking, alcohol consumption, hypertension, dyslipidemia, hemoglobin A1c and estimated glomerular filtration rate did not attenuate the strong association between NAFLD and risk of prevalent AVS (adjusted-OR 3.04, 95% CI 1.3-7.3, p = 0.01. CONCLUSIONS: Our results provide the first demonstration of a positive and independent association between NAFLD and AVS in patients with type 2 diabetes mellitus.

  18. R-R interval variations influence the degree of mitral regurgitation in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Moller, J. E.; Haggstrom, J.

    2014-01-01

    of congestive heart failure due to MMVD. The severity of MR was evaluated in apical four-chamber view using colour Doppler flow mapping (maximum % of the left atrium area) and colour Doppler M-mode (duration in ms). The influence of the ratio between present and preceding R-R interval on MR severity......Mitral regurgitation (MR) due to myxomatous mitral valve disease (MMVD) is a frequent finding in Cavalier King Charles Spaniels (CKCSs). Sinus arrhythmia and atrial premature complexes leading to R-R interval variations occur in dogs. The aim of the study was to evaluate whether the duration...... of the RR interval immediately influences the degree of MR assessed by echocardiography in dogs. Clinical examination including echocardiography was performed in 103 privately-owned dogs: 16 control Beagles, 70 CKCSs with different degree of MR and 17 dogs of different breeds with clinical signs...

  19. Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease

    NARCIS (Netherlands)

    van Ooij, Pim; Garcia, Julio; Potters, Wouter V.; Malaisrie, S. Chris; Collins, Jeremy D.; Carr, James C.; Markl, Michael; Barker, Alex J.

    2016-01-01

    To investigate age-related changes in peak systolic aortic 3D velocity and wall shear stress (WSS) in healthy controls and to investigate the importance of age-matching for 3D mapping of abnormal aortic hemodynamics in bicuspid aortic valve disease (BAV). 4D flow MRI (fields strengths = 1.5-3T;

  20. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life.

    Science.gov (United States)

    Anjos, Daniela Brianne Martins Dos; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista Dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-12-19

    evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo m

  1. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  2. A Comparative Experimental Study on the Use of Machine Learning Approaches for Automated Valve Monitoring Based on Acoustic Emission Parameters

    Science.gov (United States)

    Ali, Salah M.; Hui, K. H.; Hee, L. M.; Salman Leong, M.; Al-Obaidi, M. A.; Ali, Y. H.; Abdelrhman, Ahmed M.

    2018-03-01

    Acoustic emission (AE) analysis has become a vital tool for initiating the maintenance tasks in many industries. However, the analysis process and interpretation has been found to be highly dependent on the experts. Therefore, an automated monitoring method would be required to reduce the cost and time consumed in the interpretation of AE signal. This paper investigates the application of two of the most common machine learning approaches namely artificial neural network (ANN) and support vector machine (SVM) to automate the diagnosis of valve faults in reciprocating compressor based on AE signal parameters. Since the accuracy is an essential factor in any automated diagnostic system, this paper also provides a comparative study based on predictive performance of ANN and SVM. AE parameters data was acquired from single stage reciprocating air compressor with different operational and valve conditions. ANN and SVM diagnosis models were subsequently devised by combining AE parameters of different conditions. Results demonstrate that ANN and SVM models have the same results in term of prediction accuracy. However, SVM model is recommended to automate diagnose the valve condition in due to the ability of handling a high number of input features with low sampling data sets.

  3. Triple-orifice valve repair in severe Barlow disease with multiple-jet mitral regurgitation: report of mid-term experience.

    Science.gov (United States)

    Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto

    2013-09-10

    Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Ideal Experimental Rat Models for Liver Diseases

    OpenAIRE

    Lee, Sang Woo; Kim, Sung Hoon; Min, Seon Ok; Kim, Kyung Sik

    2011-01-01

    There are many limitations for conducting liver disease research in human beings due to the high cost and potential ethical issues. For this reason, conducting a study that is difficult to perform in humans using appropriate animal models, can be beneficial in ascertaining the pathological physiology, and in developing new treatment modalities. However, it is difficult to determine the appropriate animal model which is suitable for research purposes, since every patient has different and dive...

  5. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  6. ESC Working Group on Valvular Heart Disease position paper--heart valve clinics: organization, structure, and experiences.

    Science.gov (United States)

    Lancellotti, Patrizio; Rosenhek, Raphael; Pibarot, Philippe; Iung, Bernard; Otto, Catherine M; Tornos, Pilar; Donal, Erwan; Prendergast, Bernard; Magne, Julien; La Canna, Giovanni; Piérard, Luc A; Maurer, Gerald

    2013-06-01

    With an increasing prevalence of patients with valvular heart disease (VHD), a dedicated management approach is needed. The challenges encountered are manifold and include appropriate diagnosis and quantification of valve lesion, organization of adequate follow-up, and making the right management decisions, in particular with regard to the timing and choice of interventions. Data from the Euro Heart Survey have shown a substantial discrepancy between guidelines and clinical practice in the field of VHD and many patients are denied surgery despite having clear indications. The concept of heart valve clinics (HVCs) is increasingly recognized as the way to proceed. At the same time, very few centres have developed such expertise, indicating that specific recommendations for the initial development and subsequent operating requirements of an HVC are needed. The aim of this position paper is to provide insights into the rationale, organization, structure, and expertise needed to establish and operate an HVC. Although the main goal is to improve the clinical management of patients with VHD, the impact of HVCs on education is of particular importance: larger patient volumes foster the required expertise among more senior physicians but are also fundamental for training new cardiologists, medical students, and nurses. Additional benefits arise from research opportunities resulting from such an organized structure and the delivery of standardized care protocols. The growing volume of patients with VHD, their changing characteristics, and the growing technological opportunities of refined diagnosis and treatment in addition to the potential dismal prognosis if overlooked mandate specialized evaluation and care by dedicated physicians working in a specialized environment that is called the HVC.

  7. Engineering a 3D-Bioprinted Model of Human Heart Valve Disease Using Nanoindentation-Based Biomechanics

    Directory of Open Access Journals (Sweden)

    Dewy C. van der Valk

    2018-05-01

    Full Text Available In calcific aortic valve disease (CAVD, microcalcifications originating from nanoscale calcifying vesicles disrupt the aortic valve (AV leaflets, which consist of three (biomechanically distinct layers: the fibrosa, spongiosa, and ventricularis. CAVD has no pharmacotherapy and lacks in vitro models as a result of complex valvular biomechanical features surrounding resident mechanosensitive valvular interstitial cells (VICs. We measured layer-specific mechanical properties of the human AV and engineered a three-dimensional (3D-bioprinted CAVD model that recapitulates leaflet layer biomechanics for the first time. Human AV leaflet layers were separated by microdissection, and nanoindentation determined layer-specific Young’s moduli. Methacrylated gelatin (GelMA/methacrylated hyaluronic acid (HAMA hydrogels were tuned to duplicate layer-specific mechanical characteristics, followed by 3D-printing with encapsulated human VICs. Hydrogels were exposed to osteogenic media (OM to induce microcalcification, and VIC pathogenesis was assessed by near infrared or immunofluorescence microscopy. Median Young’s moduli of the AV layers were 37.1, 15.4, and 26.9 kPa (fibrosa/spongiosa/ventricularis, respectively. The fibrosa and spongiosa Young’s moduli matched the 3D 5% GelMa/1% HAMA UV-crosslinked hydrogels. OM stimulation of VIC-laden bioprinted hydrogels induced microcalcification without apoptosis. We report the first layer-specific measurements of human AV moduli and a novel 3D-bioprinted CAVD model that potentiates microcalcification by mimicking the native AV mechanical environment. This work sheds light on valvular mechanobiology and could facilitate high-throughput drug-screening in CAVD.

  8. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  9. Cardiac valve disease: an unreported feature in Ehlers Danlos syndrome arthrocalasia type?

    Directory of Open Access Journals (Sweden)

    Melis Daniela

    2012-11-01

    Full Text Available Abstract Ehlers Danlos syndrome (EDS athrocalasia type (type VII, is characterized by joint hypermobility, skin hyperextensibility and tissue fragility. No heart involvement has been reported. Two forms have been described: type VII A and VII B. The abnormally processed collagen α2(I and the skipping of the exon 6 in COL1A2 gene are typically detected in EDS type VII B. We describe a seven-year old female, with a phenotype consistent with EDS type VII B and a diagnosis further confirmed by biochemical and molecular analyses. Cardiac ultrasound showed normal data in the first year of life. When she was 5 years old, the patient developed mitral valve regurgitation, and aortic and tricuspidal insufficiency at 7 years of age. To our knowledge, this is the first report of cardiac valvular involvement in EDS VII B. This feature probably has been underreported for the limited follow-up of the patients. Echocardiography might be warranted in the clinical assessment of EDS VII patients.

  10. Analysis of cardiac energy metabolism in valve disease using 31P-MR-spectroscopy

    International Nuclear Information System (INIS)

    Beer, M.; Viehrig, M.; Seyfarth, T.; Sandstede, J.; Lipke, C.; Pabst, T.; Kenn, W.; Hahn, D.; Harre, K.; Horn, M.; Neubauer, S.; Landschuetz, W.; Kienlin, M. von

    2000-01-01

    Patients and methods: 10 healthy volunteers and 10 patients with aortic stenosis (pressure gradients >60 mmHg) were included. For assessment of energy metabolism, 31 P-MR spectra were obtained with a double oblique 3D-CSI technique (voxel size 25 cm 3 ). In 5 of 10 patients, follow-up examination was performed 3 months after surgical valve replacement (SVR). Left ventricular (LV) function was analyzed by cine MRI. Results: Before SVR the myocardial phosphocreatine to adenosinetriphosphate (PCr-ATP) ratio was significantly (p=0.0002) reduced to 0.80±0.25 in patients compared to 1.65±0.21 in volunteers. 3 months after SVR, LV mass had significantly (p=0.04) decreased from 238±33 g to 206±47 g. At the same time a significant (p=0.04) increase of the PCr-ATP ratio from 0.80±0.25 to 1.28±0.22 was observed. A slight, but not significant, reduction of the phosphodiester ATP ratio was observed before SVR, with a trend towards normalization after SVR. (orig.) [de

  11. Ideal Experimental Rat Models for Liver Diseases.

    Science.gov (United States)

    Lee, Sang Woo; Kim, Sung Hoon; Min, Seon Ok; Kim, Kyung Sik

    2011-05-01

    There are many limitations for conducting liver disease research in human beings due to the high cost and potential ethical issues. For this reason, conducting a study that is difficult to perform in humans using appropriate animal models, can be beneficial in ascertaining the pathological physiology, and in developing new treatment modalities. However, it is difficult to determine the appropriate animal model which is suitable for research purposes, since every patient has different and diverse clinical symptoms, adverse reactions, and complications due to the pathological physiology. Also, it is not easy to reproduce identically various clinical situations in animal models. Recently, the Guide for the Care and Use of Laboratory Animals has tightened up the regulations, and therefore it is advisable to select the appropriate animals and decide upon the appropriate quantities through scientific and systemic considerations before conducting animal testing. Therefore, in this review article the authors examined various white rat animal testing models and determined the appropriate usable rat model, and the pros and cons of its application in liver disease research. The authors believe that this review will be beneficial in selecting proper laboratory animals for research purposes.

  12. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  13. Theoretical and Experimental Studies of a Switched Inertance Hydraulic System in a Four-Port High-Speed Switching Valve Configuration

    Directory of Open Access Journals (Sweden)

    Min Pan

    2017-06-01

    Full Text Available The switched inertance hydraulic system (SIHS is a novel high-bandwidth and energy-efficient digital device which can adjust or control flow and pressure by a means that does not rely on throttling the flow and dissipation of power. An SIHS can provide an efficient step-up or step-down of pressure or flow rate by using a digital control signal. In this article, analytical models of an SIHS in a four-port high-speed switching valve configuration are proposed, and the system dynamics and performance are investigated theoretically and experimentally. The flow responses, system characteristics, and power consumption can be predicted effectively and accurately by using the proposed models, which were validated by comparing with experiments and with numerical simulation. The four-port configuration is compared with the three-port configuration, and it is concluded that the former one is less efficient for valves of the same size, but provides a bi-direction control capability. As bi-direction control is a common requirement, this constitutes an important contribution to the development of efficient digital hydraulics.

  14. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  15. Dynamic and quantitative evaluation of degenerative mitral valve disease: a dedicated framework based on cardiac magnetic resonance imaging.

    Science.gov (United States)

    Sturla, Francesco; Onorati, Francesco; Puppini, Giovanni; Pappalardo, Omar A; Selmi, Matteo; Votta, Emiliano; Faggian, Giuseppe; Redaelli, Alberto

    2017-04-01

    Accurate quantification of mitral valve (MV) morphology and dynamic behavior over the cardiac cycle is crucial to understand the mechanisms of degenerative MV dysfunction and to guide the surgical intervention. Cardiac magnetic resonance (CMR) imaging has progressively been adopted to evaluate MV pathophysiology, although a dedicated framework is required to perform a quantitative assessment of the functional MV anatomy. We investigated MV dynamic behavior in subjects with normal MV anatomy (n=10) and patients referred to surgery due to degenerative MV prolapse, classified as fibro-elastic deficiency (FED, n=9) and Barlow's disease (BD, n=10). A CMR-dedicated framework was adopted to evaluate prolapse height and volume and quantitatively assess valvular morphology and papillary muscles (PAPs) function over the cardiac cycle. Multiple comparison was used to investigate the hallmarks associated to MV degenerative prolapse and evaluate the feasibility of anatomical and functional distinction between FED and BD phenotypes. On average, annular dimensions were significantly (Pframework allows for the quantitative and dynamic evaluation of MV apparatus, with quantifiable annular alterations representing the primary hallmark of severe MV degeneration. This may aid surgeons in the evaluation of the severity of MV dysfunction and the selection of the appropriate MV treatment.

  16. Diagnostic Value of Selected Echocardiographic Variables to Identify Pulmonary Hypertension in Dogs with Myxomatous Mitral Valve Disease.

    Science.gov (United States)

    Tidholm, A; Höglund, K; Häggström, J; Ljungvall, I

    2015-01-01

    Pulmonary hypertension (PH) is commonly associated with myxomatous mitral valve disease (MMVD). Because dogs with PH present without measureable tricuspid regurgitation (TR), it would be useful to investigate echocardiographic variables that can identify PH. To investigate associations between estimated systolic TR pressure gradient (TRPG) and dog characteristics and selected echocardiographic variables. 156 privately owned dogs. Prospective observational study comparing the estimations of TRPG with dog characteristics and selected echocardiographic variables in dogs with MMVD and measureable TR. Tricuspid regurgitation pressure gradient was significantly (P modeled as linear variables LA/Ao (P modeled as second order polynomial variables: AT/DT (P = .0039) and LVIDDn (P value for the final model was 0.45 and receiver operating characteristic curve analysis suggested the model's performance to predict PH, defined as 36, 45, and 55 mmHg as fair (area under the curve [AUC] = 0.80), good (AUC = 0.86), and excellent (AUC = 0.92), respectively. In dogs with MMVD, the presence of PH might be suspected with the combination of decreased PA AT/DT, increased RVIDDn and LA/Ao, and a small or great LVIDDn. Copyright © 2015 The Authors Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. The changing course of aortic valve disease in Scotland:temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis

    OpenAIRE

    Berry, Colin; Lloyd, Suzanne M; Wang, Yanzhong; Macdonald, Alyson; Ford, Ian

    2013-01-01

    Aims: To investigate the contemporary clinical course of aortic valve disease types.Methods and results: We performed a retrospective population-level epidemiological study of hospitalized care in Scotland from 1 January 1997 to 31 December 2005 using electronic case identification of hospital admissions and deaths. Time-to-event analyses were performed using Cox Proportional-Hazards models. A total of 19 733 adults with an index hospitalization and a final diagnosis of non-congenital aortic ...

  18. INFLUENCE OF GRADED AEROBIC EXERCISE ON QUALITY OF LIFE IN POST SURGICAL MITRAL VALVE DISEASE INDIVIDUAL A PROSPECTIVE RANDOMIZED OPEN LABEL STUDY

    Directory of Open Access Journals (Sweden)

    Shanthi C

    2016-10-01

    Full Text Available Background: Post surgical mitral valve disease individual focus their cardiac rehabilitation training on two major goal that is to improve cardiac output response exercises and place an important role in determining exercise tolerance and to improve quality of life. Cardiac rehabilitation programs involve prescribed exercise and education however various other method are being used to improve quality of life. But our study to find out the effectiveness of graded aerobic exercise protocol on ejection fraction and quality of life in post surgical mitral valve disease individuals. Methods: The study design was open label studies total of 100 post surgical mitral valve disease individuals patients from the age group of 20-60 years were recruited from SVIMS hospital. They were randomly divided into two groups. Group I underwent a twelve week structured graded individually tailored exercises. The group II received only none graded (not individualized exercise training. The ejection fraction and quality of life was measured before and after 12 weeks of exercise training for two groups. Results: Repeated measures ANOVA was used to compare mean values of continuous variables between baseline and at the time of discharge and three months after surgery for each parameter. Comparison of means between groups was done by the unpaired student t test. Mean age of the subjects was 40.18±10.29. There was a significant increase in the ejection fraction in the group I(61.34±2.49 to 64.4±3.31 compared to with the group II (61.06±2.51. to 61.62 ±2.37. QOL had improved in group I than group II at p<0.05. Conclusion: A 12 week structured graded aerobic exercise training significantly improved ejection fraction and quality of life in post surgical mitral valve disease individuals.

  19. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  20. Intravenous administration of puppy deciduous teeth stem cells in degenerative valve disease

    Directory of Open Access Journals (Sweden)

    Soontaree Petchdee

    2016-12-01

    Full Text Available Aim: The objective of this study is to investigate the improvement of heart function in dogs with chronic valvular heart disease after puppy deciduous teeth stem cells (pDSCs administration. Materials and Methods: 20 client-owned dogs with degenerative valvular heart disease underwent multiple intravenous injections of allogeneic pDSCs. Dogs were randomly assigned to two groups: (i Control group (n=10 with standard treatment for heart failure and (ii group with standard treatment and multiple administrations of pDSCs (n=10. Electrocardiography, complete transthoracic echocardiography, thoracic radiography, and blood pressure were recorded before and after pDSCs injections for 15, 30 and 60 days. Results: Post pDSCs injection showed measurable improvement in left ventricular ejection fraction, American College of Veterinary Internal Medicine (ACVIM functional class significantly improved and improved quality of life scores were observed. In the control group, there were no significant enhancements in heart function or ACVIM class. Conclusions: This finding suggests that pDSCs could be a supplement for valvular heart disease treatment.

  1. Outcomes of patients with chronic lung disease and severe aortic stenosis treated with transcatheter versus surgical aortic valve replacement or standard therapy: insights from the PARTNER trial (placement of AoRTic TraNscathetER Valve).

    Science.gov (United States)

    Dvir, Danny; Waksman, Ron; Barbash, Israel M; Kodali, Susheel K; Svensson, Lars G; Tuzcu, E Murat; Xu, Ke; Minha, Sa'ar; Alu, Maria C; Szeto, Wilson Y; Thourani, Vinod H; Makkar, Raj; Kapadia, Samir; Satler, Lowell F; Webb, John G; Leon, Martin B; Pichard, Augusto D

    2014-01-28

    The study aimed to evaluate the impact of chronic lung disease (CLD) on outcomes of severe aortic stenosis patients across all treatment modalities. Outcomes of patients with CLD undergoing transcatheter aortic valve replacement (TAVR) have not been systematically examined. All patients who underwent TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve) trial, including the continued access registry (n = 2,553; 1,108 with CLD), were evaluated according to CLD clinical severity. Additionally, outcomes of CLD patients included in the randomization arms of the PARTNER trial were compared: Cohort A patients (high-risk operable) treated by either TAVR (n = 149) or surgical aortic valve replacement (SAVR); (n = 138); and Cohort B patients (inoperable) treated by either TAVR (n = 72) or standard therapy only (n = 95). Among all TAVR-treated patients, at 1-year follow-up, patients with CLD had higher mortality than those without it (23.4% vs. 19.6%, p = 0.02). Baseline characteristics of CLD patients who underwent TAVR were similar to respective controls. In Cohort A, 2-year all-cause death rates were similar (TAVR 35.2% and SAVR 33.6%, p = 0.92), whereas in Cohort B, the death rate was lower after TAVR (52.0% vs. 69.6% after standard therapy only, p = 0.04). Independent predictors for mortality in CLD patients undergoing TAVR included poor mobility (6-min walk test CLD patients undergoing TAVR have worse outcomes than patients without CLD, TAVR is better in these patients than standard therapy and is similar to SAVR. Although patients with CLD undergoing TAVR had worse outcomes than patients without CLD, TAVR performed better in these patients than standard therapy and was similar to SAVR. However, CLD patients who were either poorly mobile or oxygen-dependent had poor outcomes. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  2. Circulating cytokine concentrations in dogs with different degrees of myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Zois, Nora Elisabeth; Moesgaard, Sophia Gry; Kjelgaard-Hansen, Mads

    2012-01-01

    , IL-15, IL-18, keratinocyte-derived chemokine, interferon-c-induced protein and monocyte chemoattractant protein-1 (MCP-1) were measured using a canine-specific multiplex immunoassay. CHF dogs had significantly higher MCP-1 concentrations than dogs with no or minimal MR. Among the CKCS, IL-2 and IL-7...... decreased with increasing left atrial size and IL-7 also decreased with increasing MR. IL-8 decreased with increasing left ventricular end-systolic internal dimensions. MCP-1 was increased in CHF dogs compared to healthy control dogs and IL-2, IL-7 and IL-8 decreased with increasing indices of disease...

  3. Veterinary Medicine and Multi-Omics Research for Future Nutrition Targets: Metabolomics and Transcriptomics of the Common Degenerative Mitral Valve Disease in Dogs.

    Science.gov (United States)

    Li, Qinghong; Freeman, Lisa M; Rush, John E; Huggins, Gordon S; Kennedy, Adam D; Labuda, Jeffrey A; Laflamme, Dorothy P; Hannah, Steven S

    2015-08-01

    Canine degenerative mitral valve disease (DMVD) is the most common form of heart disease in dogs. The objective of this study was to identify cellular and metabolic pathways that play a role in DMVD by performing metabolomics and transcriptomics analyses on serum and tissue (mitral valve and left ventricle) samples previously collected from dogs with DMVD or healthy hearts. Gas or liquid chromatography followed by mass spectrophotometry were used to identify metabolites in serum. Transcriptomics analysis of tissue samples was completed using RNA-seq, and selected targets were confirmed by RT-qPCR. Random Forest analysis was used to classify the metabolites that best predicted the presence of DMVD. Results identified 41 known and 13 unknown serum metabolites that were significantly different between healthy and DMVD dogs, representing alterations in fat and glucose energy metabolism, oxidative stress, and other pathways. The three metabolites with the greatest single effect in the Random Forest analysis were γ-glutamylmethionine, oxidized glutathione, and asymmetric dimethylarginine. Transcriptomics analysis identified 812 differentially expressed transcripts in left ventricle samples and 263 in mitral valve samples, representing changes in energy metabolism, antioxidant function, nitric oxide signaling, and extracellular matrix homeostasis pathways. Many of the identified alterations may benefit from nutritional or medical management. Our study provides evidence of the growing importance of integrative approaches in multi-omics research in veterinary and nutritional sciences.

  4. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    Science.gov (United States)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  5. Repair of experimental plaque-induced periodontal disease in dogs.

    Science.gov (United States)

    Shoukry, M; Ben Ali, L; Abdel Naby, M; Soliman, A

    2007-09-01

    Forty mongrel dogs were used in this study for induction of periodontal disease by placing subgingival silk ligatures affecting maxillary and mandibular premolar teeth during a 12-month period. Experimental premolar teeth received monthly clinical, radiographic, and histometric/pathologic assessments. The results demonstrated significant increases in scores and values of periodontal disease parameters associated with variable degrees of alveolar bone loss. The experimental maxillary premolar teeth exhibited more severe and rapid rates of periodontal disease compared with mandibular premolar teeth. Histometric analysis showed significant reduction in free and attached gingiva of the experimental teeth. Histopathological examination of buccolingual sections from experimental premolar teeth showed the presence of rete pegs within the sulcular epithelium with acanthosis and erosive changes, widening of the periodontal ligament, and alveolar bone resorption. Various methods for periodontal repair were studied in 194 experimental premolar teeth exhibiting different degrees of periodontal disease. The treatment plan comprised non-surgical (teeth scaling, root planing, and oral hygiene) and surgical methods (closed gingival curettage, modified Widman flap, and reconstructive surgery using autogenous bone marrow graft and canine amniotic membrane). The initial non-surgical treatment resulted in a periodontal recovery rate of 37.6% and was found effective for treatment of early periodontal disease based on resolution of gingivitis and reduction of periodontal probing depths. Surgical treatment by closed gingival curettage to eliminate the diseased pocket lining resulted in a recovery rate of 48.8% and proved effective in substantially reducing deep periodontal pockets. Open root planing following flap elevation resulted in a recovery rate of 85.4% and was effective for deep and refractory periodontal pockets. Autogenous bone graft implantation combined with canine amniotic

  6. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Höllmer, M.; Willesen, J. L.; Tolver, A.

    2017-01-01

    stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100......%. An active LA emptying fraction heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. CONCLUSION: Dogs with MMVD appear to have larger LA...... of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. ANIMALS: This prospective study included 205 client-owned dogs of different breeds, 114...

  7. Clinical information has low sensitivity for postmortem diagnosis of heart valve disease.

    Science.gov (United States)

    Coffey, Sean; Harper, Andrew R; Cairns, Benjamin J; Roberts, Ian Sd; Prendergast, Bernard D

    2017-07-01

    Accuracy of routinely collected information concerning cause of death is essential for public health and health systems planning. Since clinical examination has relatively low sensitivity for detection of valvular heart disease (VHD), mortality data based on clinical information alone might routinely underestimate the number of deaths due to VHD. We compared autopsy findings against premortem clinical information for 8198 consecutive adult postmortems (mean age 69.1 years, 61.3% men), performed in a single UK tertiary referral centre with on-site cardiac surgical facilities over a 10-year period (2004-2013) during which 21% of the adult population underwent postmortem examination. Following postmortem, VHD was the principal cause of death in 165 individuals (2.0%), a principal or contributory cause ('any cause') of death in 326 (4.0%) and an incidental (ie, non-causal) finding in a further 346 (4.2%). Clinical documentation of VHD before death was highly specific but relatively insensitive for postmortem identification of VHD as the principal (specificity 96.8%; 95% CI 96.4% to 97.2%; sensitivity 69.7%, 95% CI 62.1% to 76.6%) or any (specificity 98.1%; 95% CI 97.8% to 98.4%; sensitivity 68.4%, 95% CI 63.1% to 73.4%) cause of death. VHD (principally aortic stenosis, endocarditis and rheumatic heart disease) was newly noted at postmortem and listed as a cause of death in 142 individuals (1.7%). Clinical information recorded premortem is highly specific but relatively insensitive for the cause of death established at autopsy. Population-based mortality statistics that depend on premortem clinical information are likely to routinely underestimate the mortality burden of VHD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Mitral valve prolapse - report of 3 cases

    International Nuclear Information System (INIS)

    Han, Moon Hee; Im, Chung Ki; Im, Dong Ran; Han, Man Chung; Lee, Young Woo; Seo, Jung Don

    1979-01-01

    Prolapse of mitral valve is characterized by its unique auscultatory, echocardiographic and angiographic findings and may be associated with various disease entities such as congenital heart disease, coronary heart disease and Marfan's syndrome etc. Authors report recent experience of 3 cases of prolapsed mitral valve, 2 cases associated with A.S.D. and 1 case with Marfan's syndrome.

  9. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar

    International Nuclear Information System (INIS)

    Porto Junior, Almir Carlos Soares

    2014-01-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009 th by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  10. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  11. Markers of Oxidative Stress in Dogs with Myxomatous Mitral Valve Disease are Influenced by Sex, Neuter Status, and Serum Cholesterol Concentration

    DEFF Research Database (Denmark)

    Reimann, M. J.; Haggstrom, J.; Moller, J. E.

    2017-01-01

    Background Cardiovascular disease has been associated with oxidative stress, which has been suggested to contribute to myocardial remodeling in human patients. Little is known about the relationship between myxomatous mitral valve disease (MMVD) and oxidative stress in dogs. Objective To determin...... with clinical stage of MMVD. Conclusions In conclusion, markers of oxidative stress are associated with sex, BCS, neuter status, and cholesterol. The results cannot confirm a relationship between oxidative stress and clinical stage of the disease in dogs with MMVD.......Background Cardiovascular disease has been associated with oxidative stress, which has been suggested to contribute to myocardial remodeling in human patients. Little is known about the relationship between myxomatous mitral valve disease (MMVD) and oxidative stress in dogs. Objective To determine...... whether clinical stage of MMVD is associated with changes in the plasma concentrations of certain markers of oxidative stress in clinically healthy dogs and dogs with MMVD. Animals Seventy five privately owned dogs: 59 cavalier King Charles Spaniels (CKCS) with different severities of MMVD and 16 dogs...

  12. Abnormal Gastroesophageal Flap Valve Is Associated With High Gastresophageal Reflux Disease Questionnaire Score and the Severity of Gastroesophageal Reflux Disease in Vietnamese Patients With Upper Gastrointestinal Symptoms.

    Science.gov (United States)

    Quach, Duc T; Nguyen, Trang T; Hiyama, Toru

    2018-04-30

    There have been no studies investigating the distribution of abnormal gastroesophageal flap valve (GEFV) among patients with dyspepsia, non-erosive reflux disease (NERD), and reflux esophagitis (RE) in the same set of patients. The aims of this study are to investigate (1) the association between GEFV and gastroesophageal reflux disease questionnaire (GERDQ) score, and (2) the distribution of abnormal GEFV in Vietnamese patients presenting with upper gastrointestinal symptoms. Three hundred and thirty-one patients recruited in this prospective cross-sectional study were classified into 3 groups: reflux esophagitis (RE), non-erosive reflux disease (NERD) (GERDQ score ≥ 8, no endoscopic mucosal injury), and dyspepsia (GERDQ score < 8, no endoscopic mucosal injury). The GEFV was graded endoscopically according to the Hill classification. GEFV grades I and II were regarded as normal, while grades III and IV were regarded as abnormal GEFV. There were 215 (65.0%) patients with dyspepsia, 55 (16.6%) patients with NERD, and 61 (18.4%) patients with RE. Abnormal GEFV was an independent risk factor for GERD (OR, 2.93; CI 95%, 1.76-4.88) and RE (OR, 3.41; CI 95%, 1.78-6.53). The mean GERDQ score of patients with abnormal GEFV was significantly higher than that of patients with normal GEFV (5.7 ± 2.4 vs 4.9 ± 2.7, P = 0.011). The prevalence of abnormal GEFV gradually increased in patients with dyspepsia (27.4%), NERD (43.6%), grade A RE (56.8%), and grades B/C RE (80.0%) ( P < 0.001). Abnormal GEFV was significantly associated with high GERDQ score. Its prevalence gradually increased in patients with dyspepsia, NERD, and RE, respectively.

  13. Optimising experimental research in respiratory diseases: an ERS statement.

    Science.gov (United States)

    Bonniaud, Philippe; Fabre, Aurélie; Frossard, Nelly; Guignabert, Christophe; Inman, Mark; Kuebler, Wolfgang M; Maes, Tania; Shi, Wei; Stampfli, Martin; Uhlig, Stefan; White, Eric; Witzenrath, Martin; Bellaye, Pierre-Simon; Crestani, Bruno; Eickelberg, Oliver; Fehrenbach, Heinz; Guenther, Andreas; Jenkins, Gisli; Joos, Guy; Magnan, Antoine; Maitre, Bernard; Maus, Ulrich A; Reinhold, Petra; Vernooy, Juanita H J; Richeldi, Luca; Kolb, Martin

    2018-05-01

    Experimental models are critical for the understanding of lung health and disease and are indispensable for drug development. However, the pathogenetic and clinical relevance of the models is often unclear. Further, the use of animals in biomedical research is controversial from an ethical perspective.The objective of this task force was to issue a statement with research recommendations about lung disease models by facilitating in-depth discussions between respiratory scientists, and to provide an overview of the literature on the available models. Focus was put on their specific benefits and limitations. This will result in more efficient use of resources and greater reduction in the numbers of animals employed, thereby enhancing the ethical standards and translational capacity of experimental research.The task force statement addresses general issues of experimental research (ethics, species, sex, age, ex vivo and in vitro models, gene editing). The statement also includes research recommendations on modelling asthma, chronic obstructive pulmonary disease, pulmonary fibrosis, lung infections, acute lung injury and pulmonary hypertension.The task force stressed the importance of using multiple models to strengthen validity of results, the need to increase the availability of human tissues and the importance of standard operating procedures and data quality. Copyright ©ERS 2018.

  14. Breeding Restrictions Decrease the Prevalence of Myxomatous Mitral Valve Disease in Cavalier King Charles Spaniels over an 8-to 10-Year Period

    DEFF Research Database (Denmark)

    Birkegård, Anna Camilla; Reimann, M. J.; Martinussen, T.

    2016-01-01

    Background: Cavalier King Charles Spaniels (CKCS) are predisposed to myxomatous mitral valve disease (MMVD). Studies have indicated a strong genetic background. Objective: The aim of this study was to evaluate the effect of a breeding scheme involving auscultation and echocardiography. Animals......: In the Danish Kennel Club mandatory breeding scheme, 997 purebred CKCS were examined during the period 2002-2011. Each dog was evaluated 1-4 times with a total of 1,380 examinations. Methods: Auscultation and echocardiography were performed to evaluate mitral regurgitation murmur severity and degree of mitral...... compared with dogs in 2002-2003, reflecting a 73% decreased risk (P auscultation...

  15. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  16. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  17. Management of Posterior Urethral Valves in Rural Kenya

    African Journals Online (AJOL)

    Management of Posterior Urethral Valves in Rural. Kenya .... Antwi S. Audit of Posterior Urethral Valve (PUV) in Children at ... Community Paediatrics Committee, Infectious. Diseases ... Effect of Circumcision on Risk of Urinary Tract. Infection in ...

  18. Experimental Vaccines against Chagas Disease: A Journey through History.

    Science.gov (United States)

    Rodríguez-Morales, Olivia; Monteón-Padilla, Víctor; Carrillo-Sánchez, Silvia C; Rios-Castro, Martha; Martínez-Cruz, Mariana; Carabarin-Lima, Alejandro; Arce-Fonseca, Minerva

    2015-01-01

    Chagas disease, or American trypanosomiasis, which is caused by the protozoan parasite Trypanosoma cruzi, is primarily a vector disease endemic in 21 Latin American countries, including Mexico. Although many vector control programs have been implemented, T. cruzi has not been eradicated. The development of an anti-T. cruzi vaccine for prophylactic and therapeutic purposes may significantly contribute to the transmission control of Chagas disease. Immune protection against experimental infection with T. cruzi has been studied since the second decade of the last century, and many types of immunogens have been used subsequently, such as killed or attenuated parasites and new DNA vaccines. This primary prevention strategy appears feasible, effective, safe, and inexpensive, although problems remain. The objective of this review is to summarize the research efforts about the development of vaccines against Chagas disease worldwide. A thorough literature review was conducted by searching PubMed with the terms "Chagas disease" and "American trypanosomiasis" together with "vaccines" or "immunization". In addition, reports and journals not cited in PubMed were identified. Publications in English, Spanish, and Portuguese were reviewed.

  19. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  20. Increased NT-proANP predicts risk of congestive heart failure in Cavalier King Charles spaniels with mitral regurgitation caused by myxomatous valve disease.

    Science.gov (United States)

    Eriksson, Anders S; Häggström, Jens; Pedersen, Henrik Duelund; Hansson, Kerstin; Järvinen, Anna-Kaisa; Haukka, Jari; Kvart, Clarence

    2014-09-01

    To evaluate the predictive value of plasma N-terminal pro-atrial natriuretic peptide (NT-proANP) and nitric oxide end-products (NOx) as markers for progression of mitral regurgitation caused by myxomatous mitral valve disease. Seventy-eight privately owned Cavalier King Charles spaniels with naturally occurring myxomatous mitral valve disease. Prospective longitudinal study comprising 312 measurements over a 4.5 year period. Clinical values were recorded, NT-proANP concentrations were measured by radioimmunoassay, and NOx were analyzed colorimetrically. To predict congestive heart failure (CHF), Cox proportional hazards models with time-varying covariates were constructed. The hazard ratio for NT-proANP (per 1000 pmol/l increase) to predict future CHF was 6.7 (95% confidence interval, 3.6-12.5; p 1000 pmol/l was 11 months (95% confidence interval, 5.6-12.6 months), compared to 54 months (46 - infinity) for dogs with concentrations ≤ 1000 pmol/l (p 130 beats per minute) and grade of murmur (≥ 3/6). The risk of CHF due to mitral regurgitation is increased in dogs with blood NT-proANP concentrations above 1000 pmol/l. Measurement of NT-proANP can be a valuable tool to identify dogs that may develop CHF within months. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  2. A happy valve in a happy patient? Serotonergic antidepressants and the risk of valvular heart disease (SERVAL). A case-control study.

    Science.gov (United States)

    De Backer, Tine; Petrovic, Mirko; Audenaert, Kurt; Coeman, Mathieu; De Bacquer, Dirk

    2016-02-01

    The objective was to investigate the risk of valvular heart disease in humans in relation to the use of selective serotonin reuptake inhibitors (SSRIs) and serotonin and noradrenaline reuptake inhibitors. A case-control study. We conducted a case-control study within this cohort in which patients with newly diagnosed cardiac valve regurgitation were age-matched to controls. Patient demographics, their cardiovascular risk factors and medication use were extracted in both series. Use of SSRIs, serotonin and noradreline reuptake inhibitors (SNRIs) and other pro-serotonergic agents, their dose and treatment duration were recorded. Logistic regression analysis was used to establish the strength of the association between SSRI/SNRI use and valvular heart disease. Outpatient clinic of the cardiology department at the Ghent University Hospital, East-Flanders in Belgium. Total of 2911 persons 21-58 years of age who had undergone an echocardiogram in the period 2006-2010 and had no known cardiovascular disease or previous cardiac intervention. Two hundred and six echocardiographically proven cases of valvular regurgitation and 195 matched controls. Odd ratio of valvular disease associated with intake of serotonergic drugs. Of the 206 patients with newly diagnosed cardiac valve regurgitation, 11.6% were exposed to serotonergic agents compared to 4.1% in the 195 control patients, leading to an odds ratio of 3.08 (95% confidence interval [CI] 1.35-7.04). The analysis of doses and treatment durations revealed a dose-relationship pattern between SSRI/SNRI use and prevalent valvular heart disease. In this study, use of serotonergic antidepressants was associated with an increased rate of valvular regurgitation in humans.

  3. Mutations that Cause Human Disease: A Computational/Experimental Approach

    Energy Technology Data Exchange (ETDEWEB)

    Beernink, P; Barsky, D; Pesavento, B

    2006-01-11

    can be used to understand how an amino acid change affects the protein. The experimental methods that provide the most detailed structural information on proteins are X-ray crystallography and NMR spectroscopy. However, these methods are labor intensive and currently cannot be carried out on a genomic scale. Nonetheless, Structural Genomics projects are being pursued by more than a dozen groups and consortia worldwide and as a result the number of experimentally determined structures is rising exponentially. Based on the expectation that protein structures will continue to be determined at an ever-increasing rate, reliable structure prediction schemes will become increasingly valuable, leading to information on protein function and disease for many different proteins. Given known genetic variability and experimentally determined protein structures, can we accurately predict the effects of single amino acid substitutions? An objective assessment of this question would involve comparing predicted and experimentally determined structures, which thus far has not been rigorously performed. The completed research leveraged existing expertise at LLNL in computational and structural biology, as well as significant computing resources, to address this question.

  4. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  5. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  6. Role of Pre-incision, Intravenous Prophylactic Amiodarone to Control Arrhythmias in Patients with Rheumatic Valvular Heart Disease undergoing Mitral Valve Replacement

    International Nuclear Information System (INIS)

    Ahmad, K.; Naqvi, S.

    2013-01-01

    Objective: To evaluate the effect of intra-operative single intra venous dose of amiodarone on post operative cardiac arrhythmias in patients undergoing valvular heart surgery. Study Design: Randomized controlled trials. Place and Duration of surgery: This study was performed at Armed forces Institute of Cardiology Rawalpindi from Jan 01, 2011 to Dec 31, 2011. Patients and Methods: In this study 80 patients with rheumatic valvular heart disease and undergoing elective mitral valve replacement were randomly divided into two groups. Group I, n = 40 (Amiodarone group) was given single intravenous dose of amiodarone (5 mg/kg in 100 ml of saline over 30 min) before sternotomy incision. Group II, n = 40(control / placebo group) was given 100 ml of saline over 30 min. Result: In the amiodarone group, after removal of aortic cross clamp 75% patients had sinus rhythm compared to 47.5% in control group. p=0.045. Similarly 15% had AF, 5% JR and 5% VT/VF in amiodarone group in contrast to 32.5% with AF, 12.5% JR and 7.5% Vt/VF in control group. (p=0.045). Response to cardioversion was positive in 75% of the patients requiring shocks in amiodarone group as against 43.75% in the control group. (p=0.044). Conclusion: A single intravenous bolus dose of amiodarone is effective in decreasing the incidence of cardiac arrhythmias after mitral valve replacement in patients with rheumatic MVD. (author)

  7. Investigations on pneumatically forced-actuated compressor valves

    Science.gov (United States)

    Stöckel, Christian; Thomas, Christiane; Nickl, Jörg; Hesse, Ullrich

    2017-08-01

    In the present paper the performance of a novel designed valve for reciprocating piston machines is investigated, which makes existing compressors utilizable for operating as expander. Three design parameters were identified as critical for the valves performance particularly in forced actuated mode. Within a numerical simulation a study on the crucial geometrical parameters, the influence could be observed. Afterwards the experimental setup for the integral test of the valve design is presented and also additional tests for single valve components.

  8. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  9. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  10. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  11. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  12. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  13. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  14. Mitral valve prolapse - report of 3 cases

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Im, Chung Ki; Im, Dong Ran; Han, Man Chung; Lee, Young Woo; Seo, Jung Don [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-12-15

    Prolapse of mitral valve is characterized by its unique auscultatory, echocardiographic and angiographic findings and may be associated with various disease entities such as congenital heart disease, coronary heart disease and Marfan's syndrome etc. Authors report recent experience of 3 cases of prolapsed mitral valve, 2 cases associated with A.S.D. and 1 case with Marfan's syndrome.

  15. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  16. Feeder density enhances house finch disease transmission in experimental epidemics.

    Science.gov (United States)

    Moyers, Sahnzi C; Adelman, James S; Farine, Damien R; Thomason, Courtney A; Hawley, Dana M

    2018-05-05

    Anthropogenic food provisioning of wildlife can alter the frequency of contacts among hosts and between hosts and environmental sources of pathogens. Despite the popularity of garden bird feeding, few studies have addressed how feeders influence host contact rates and disease dynamics. We experimentally manipulated feeder density in replicate aviaries containing captive, pathogen-naive, groups of house finches ( Haemorhous mexicanus ) and continuously tracked behaviours at feeders using radio-frequency identification devices. We then inoculated one bird per group with Mycoplasma gallisepticum (Mg), a common bacterial pathogen for which feeders are fomites of transmission, and assessed effects of feeder density on house finch behaviour and pathogen transmission. We found that pathogen transmission was significantly higher in groups with the highest density of bird feeders, despite a significantly lower rate of intraspecific aggressive interactions relative to the low feeder density groups. Conversely, among naive group members that never showed signs of disease, we saw significantly higher concentrations of Mg-specific antibodies in low feeder density groups, suggesting that birds in low feeder density treatments had exposure to subclinical doses of Mg. We discuss ways in which the density of garden bird feeders could play an important role in mediating the intensity of Mg epidemics.This article is part of the theme issue 'Anthropogenic resource subsidies and host-parasite dynamics in wildlife'. © 2018 The Author(s).

  17. Left atrial and left ventricular diastolic function after the maze procedure for atrial fibrillation in mitral valve disease: degenerative versus rheumatic.

    Science.gov (United States)

    Kim, Hwan Wook; Moon, Mi Hyoung; Jo, Keon Hyun; Song, Hyun; Lee, Jae Won

    2015-02-01

    The present study was aimed to compare the left atrial and left ventricular diastolic functions amongst the rheumatic and degenerative mitral valve disease patients in atrial fibrillation who reverted to normal sinus rhythm following Cox-maze procedure. We prospectively investigated the left atrial and left ventricular function with Doppler echocardiography, by dividing into the rheumatic (N = 105) and the degenerative group (N = 47). Over the follow-up period (mean: 4.4 ± 1.2 years in the rheumatic group, 4.8 ± 1.3 years in the degenerative group), the rheumatic group showed statistically significant decrease in A' velocity and E' velocity, on contrary to degenerative group (A' velocity: mean decrease of 0.43 ± 0.13 cm/s in the rheumatic group, mean increase of 0.57 ± 0.11 cm/s in the degenerative group, p = 0.029, E' velocity: mean decrease of 0.23 ± 0.17 cm/s in the rheumatic group, mean increase of 0.21 ± 0.15 cm/s in the degenerative group, p = 0.031). In addition, the rheumatic group showed statistically significant increase in E/E' ratio than the degenerative group (mean increase of 4.49 ± 1.98 in the rheumatic group, mean increase of 1.74 ± 1.52 in the degenerative group, p = 0.047). Despite successful sinus rhythm restoration, the progressive loss of LA function as well as LV diastolic function is more prominent in the rheumatic group than the degenerative group. Therefore, differentiated strategies for postoperative surveillance are needed according to the pathology of mitral valve disease.

  18. Alpha-smooth muscle actin and serotonin receptors 2A and 2B in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Cremer, Signe Emilie; Moesgaard, S. G.; Rasmussen, C. E.

    2015-01-01

    suggested. In an age-matched population of dogs with non-clinical and clinical MMVD, the objectives were to investigate (1) gene expression of 5-HT2AR and 5-HT2BR, (2) protein expression and spatial relationship of 5-HT2AR, 5-HT2BR and MF in the mitral valve (MV) and the cardiac anterior papillary muscle...... (AP) and (3) serum 5-HT concentrations. Gene expression of 5-HT2BR was significantly higher in MV and AP among dogs with clinical MMVD. This was not found for 5-HT2BR protein expression, though association of 5-HT2BR with myxomatous pathology and co-localization of 5-HT2BR and MF in MV and AP support...

  19. Water hammer and column separation due to accidental simultaneous closure of control valves in a large scale two-phase flow experimental test rig

    NARCIS (Netherlands)

    Bergant, A.; Westende, van 't J.M.C.; Koppel, T.; Gale, J.; Hou, Q.; Pandula, Z.; Tijsseling, A.S.

    2010-01-01

    A large-scale pipeline test rig at Deltares, Delft, The Netherlands has been used for filling and emptying experiments. Tests have been conducted in a horizontal 250 mm diameter PVC pipe of 258 m length with control valves at the downstream and upstream ends. This paper investigates the accidental

  20. Cavitation noise from butterfly valves

    International Nuclear Information System (INIS)

    Rahmeyer, W.J.

    1982-01-01

    Cavitation in valves can produce levels of intense noise. It is possible to mathematically express a limit for a design level of cavitation noise in terms of the cavitation parameter sigma. Using the cavitation parameter or limit, it is then possible to calculate the flow conditions at which a design level of cavitation noise will occur. However, the intensity of cavitation increases with the upstream pressure and valve size at a constant sigma. Therefore, it is necessary to derive equations to correct or scale the cavitation limit for the effects of different upstream pressures and valve sizes. The following paper discusses and presents experimental data for the caviation noise limit as well as the cavitation limits of incipient, critical, incipient damage, and choking cavitation for butterfly valves. The main emphasis is on the design limit of caviation noise, and a noise level of 85 decibels was selected as the noise limit. Tables of data and scaling exponents are included for applying the design limits for the effects of upstream pressure and valve size. (orig.)

  1. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  2. Cardiac taurine and principal amino acids in right and left ventricles of patients with either aortic valve stenosis or coronary artery disease:the importance of diabetes and gender

    OpenAIRE

    Lewis, Martin J; Littlejohns, Ben R; Lin, Hua; Angelini, Gianni D; Suleiman, M-Saadeh

    2014-01-01

    Free intracellular taurine and principal α-amino acids (glutamate, glutamine, aspartate, asparagine and alanine) are abundant in human heart. They are cellular regulators and their concentration can change in response to disease and cardiac insults and have been shown to differ between hypertrophic left ventricle (LV) and the relatively "normal" right ventricle (RV) in patients with aortic valve stenosis (AVS). This difference has not been shown for coronary artery disease (CAD) and there are...

  3. Is aortopathy in bicuspid aortic valve disease a congenital defect or a result of abnormal hemodynamics? A critical reappraisal of a one-sided argument.

    Science.gov (United States)

    Girdauskas, Evaldas; Borger, Michael A; Secknus, Maria-Anna; Girdauskas, Gracijus; Kuntze, Thomas

    2011-06-01

    Although there is adequate evidence that bicuspid aortic valve (BAV) is an inheritable disorder, there is a great controversy regarding the pathogenesis of dilatation of the proximal aorta. The hemodynamic theory was the first explanation for BAV aortopathy. The genetic theory, however, has become increasingly popular over the last decade and can now be viewed as the clearly dominant one. The widespread belief that BAV disease is a congenital disorder of vascular connective tissue has led to more aggressive treatment recommendations of the proximal aorta in such patients, approaching aortic management recommendations for patients with Marfan syndrome. There is emerging evidence that the 'clinically normal' BAV is associated with abnormal flow patterns and asymmetrically increased wall stress in the proximal aorta. Recent in vitro and in vivo studies on BAV function provide a unique hemodynamic insight into the different phenotypes of BAV disease and asymmetry of corresponding aortopathy even in the presence of a 'clinically normal' BAV. On the other hand, there is a subgroup of young male patients with BAV and a root dilatation phenotype, who may present the predominantly genetic form of BAV disease. In the face of these important findings, we feel that a critical review of this clinical problem is timely and appropriate, as the prevailing BAV-aortopathy theory undoubtedly affects the surgical approach to this common clinical entity. Thorough analysis of the recent literature shows a growing amount of evidence supporting the hemodynamic theory of aortopathy in patients with BAV disease. Data from recent studies requires a reevaluation of our overwhelming support of the genetic theory, and obliges us to acknowledge that hemodynamics plays an important role in the development of this disease process. Given the marked heterogeneity of BAV disease, further studies are required in order to more precisely determine which theory is the 'correct' one for explaining the

  4. Comparison of outcomes of tricuspid annuloplasty with 3D-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease.

    Science.gov (United States)

    Wang, Haiping; Liu, Xiancheng; Wang, Xin; Lv, Zhenqian; Liu, Xiaojun; Xu, Ping

    2016-11-01

    Annuloplasty bands and rings are widely used for repairing functional tricuspid regurgitation (FTR). However, the question regarding which is the ideal annuloplasty device remains unclear. The aim of this study was to compare the efficacy and mid-term durability of tricuspid ring annuloplasty for FTR secondary to rheumatic mitral valve disease using flexible Cosgrove-Edwards band and the rigid Edwards MC3 ring (Edwards Lifesciences, LLC, Irvine, CA, USA). We retrospectively collected the clinical data of those who underwent mitral valve replacement (MVR) in concomitant with tricuspid ring annuloplasty from 2009 to 2013. The flexible band was used in 46 patients (flexible group), and the 3D rigid ring was used in 60 patients (rigid group). Echocardiographic evaluation of tricuspid function was performed preoperatively and postoperatively. The grade of TR was significantly improved compared to preoperative values in two groups. There was no significant difference regarding postoperative TR grade between the two groups at 1 week and 2-3 months but there was statistical significant difference at postoperative 6-12 months, and 2-3 years. During the follow up period, 25 of 46 patients (54.3%) in flexible group and 22 of 60 patients (30.3%) in rigid group developed recurrent TR. Freedom from recurrent TR in flexible group is significant lower than rigid group in each postoperative follow up period. These findings suggest that 3D rigid ring annuloplasty might be more effective for tricuspid ring annuloplasty in FTR in mid-term postoperative periods when compared to flexible band.

  5. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  6. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  7. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  8. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  9. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  10. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  11. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  12. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  13. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  14. Fatty acid metabolism in symptomatic patients with mitral valve prolapse but without coronary artery disease - comparison with 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Voth, E.; Schicha, H.; Neumann, P.; Emrich, D.; Tebbe, U.

    1987-01-01

    Using 123 I-ω-heptadecanoic acid (HDA) and 201 Tl, respectively, myocardial fatty acid metabolism and perfusion were studied in 51 symptomatic patients with mitral valve prolapse (MVP) as diagnosed by ventriculography, and no evidence of coronary artery disease. Twelve subjects with normal coronary arteries and normal ventriculogram served as a control group for the evaluation of elimination kinetics of HDA. In the control group, the mean elimination half-life was 26.1±3.6 min, whereas the patients with MVP had a mean value of 25.0±6.4 min. In patients with MVP, a high incidence concerning abnormalities of accumulation and/or elimination of HDA occurred, namely accumulation defects in 31% and both prolonged and shortened elimination half-lives in 16% and 29%, respectively. Myocardial perfusion scintigraphy using 201 Tl showed abnormalities in 76%. Correlations were found between decreased uptake of HDA and prolonged elimination half-life as well as defects by 201 Tl, presumably due to ischemia based on small-vessel disease or abnormalities of cellular metabolism. (orig.) [de

  15. Periodontal bacteria DNA findings in human cardiac tissue - Is there a link of periodontitis to heart valve disease?

    Science.gov (United States)

    Ziebolz, D; Jahn, C; Pegel, J; Semper-Pinnecke, E; Mausberg, R F; Waldmann-Beushausen, R; Schöndube, F A; Danner, B C

    2018-01-15

    The aim of the study was to detect periodontal pathogens DNA in atrial and myocardial tissue, and to investigate periodontal status and their connection to cardiac tissue inflammation. In 30 patients, biopsy samples were taken from the atrium (A) and the ventricle myocardium (M) during aortic valve surgery. The dental examination included the dental and periodontal status (PS) and a collection of a microbiological sample. The detection of 11 periodontal pathogens DNA in oral and heart samples was carried out using PCR. The heart samples were prepared for detecting the LPS-binding protein (LBP), and for inflammation scoring on immunohistochemistry (IHC), comprising macrophages (CD68), LPS-binding protein receptor (CD14), and LBP (big42). 28 (93%) patients showed moderate to severe periodontitis. The periodontal pathogens in the oral samples of all patients revealed a similar distribution (3-93%). To a lesser extent and with a different distribution, these bacteria DNA were also detected in atrium and myocardium (3-27%). The LBP was detected in higher amount in atrium (0.22±0.16) versus myocardium (0.13±0.13, p=0.001). IHC showed a higher inflammation score in atrial than myocardial tissue as well as for CD14, CD68 and for LBP. Additional, periodontal findings showed a significant correlation to CD14 and CD68. The results provide evidence of the occurrence of oral bacteria DNA at the cardiac tissue, with a different impact on atrial and myocardial tissue inflammation. Influence of periodontal findings was identified, but their relevance is not yet distinct. Therefore further clinical investigations with long term implication are warranted. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  17. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  18. Recurrent infective endocarditis causing heart valve failure: A case report

    Directory of Open Access Journals (Sweden)

    Victoria McIntyre, BASc Chemical Engineering (2018 candidate

    2017-11-01

    Full Text Available Infective endocarditis (IE is an infection that does not usually respond rapidly to treatment, often because its early symptoms are non-specific. The diseased valves (native or bioprosthetic may be calcified and the thrombotic vegetations on them typically friable and embolize easily. Left untreated IE leads to damage to the infected valve and to congestive heart failure (CHF. Its treatment usually requires heart valve replacement. Our 69-year-old patient had IE, and underwent aortic valve replacement (AVR with a bioprosthesis. This case stresses the complications of IE and its tendency to recur in patients with bioprosthetic heart valves (BHV who previously had IE.

  19. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  20. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  1. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  2. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  3. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  4. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  5. Function analysis of steam isolation valves

    International Nuclear Information System (INIS)

    Persson, R.; Kilpi, K.; Noro, H.; Siikonen, T.; Sjoeberg, A.; Wallen, G.; Aakesson, H.

    1981-01-01

    Function analysis of system-medium-operated steam isolation valves has been the objective of the Swedish-Finnish IVLS project, the results of which are presented in this report. Theoretical models were to be verified against available experimental data, to some extent from the HDR blowdown experiments, which are part of a German reactor safety program. Finnish hydraulic measurements on a valve model (scale 1:2.15) have been performed to give complementary data. The analysis work has covered the thermal-hydraulic behaviour of steam isolation valves as well as phenomena related to structural mechanics. Work performed under contract with the Swedish Nuclear Power Inspectorate. (Author)

  6. Function analysis of steam isolation valves

    International Nuclear Information System (INIS)

    Persson, R.; Sjoeberg, A.; Aakesson, H.; Kilpi, K.; Noro, H.; Siikonen, T.; Wallen, G.

    1981-01-01

    Function analysis of system-medium-operated steam isolation valves has been the objective of the Swedish-Finnish IVLS project, the results of which are presented in this report. Theoretical models were to be verified against available experimental data, to some extent from the HDR blowdown experiments, which are part of a German reactor safety program. Finnish hydraulic measurements on a valve model (scale 1:2.15) have been performed to give complementary data. The analysis work has covered the thermal-hydraulic behaviour of steam isolation valves as well as phenomena related to structural mechanics. (Auth.)

  7. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  8. Mitral valve surgery in the adult Marfan syndrome patient.

    Science.gov (United States)

    Bhudia, Sunil K; Troughton, Richard; Lam, Buu-Khanh; Rajeswaran, Jeevanantham; Mills, William R; Gillinov, A Marc; Griffin, Brian P; Blackstone, Eugene H; Lytle, Bruce W; Svensson, Lars G

    2006-03-01

    Because mitral valve dysfunction in adults with Marfan syndrome is poorly characterized, this study compares mitral valve pathophysiology and morphology with that of myxomatous mitral disease, documents types of mitral valve operations, and assesses long-term survival and durability of mitral valve surgery in Marfan patients. From May 1975 to June 2000, 27 adults with Marfan syndrome underwent mitral valve surgery. Their valve pathophysiology and morphology was compared with that of 119 patients with myxomatous mitral disease undergoing surgery from September 1995 to March 1999. Survival and repair durability were assessed at follow-up. Compared with myxomatous disease patients, Marfan patients had less posterior leaflet prolapse (44% versus 70%, p = 0.01), more bileaflet (44% versus 28%, p = 0.09) and anterior leaflet prolapse (11% versus 3%, p = 0.07), and presented earlier for surgery (age 41 +/- 12 years versus 57 +/- 13, p Marfan patients had longer and thinner leaflets. Mitral valve repair was performed less frequently in Marfan (16 of 27, 59%) than myxomatous disease patients (112 of 119, 94%). There were no hospital deaths; at 10 years, survival was 80% and freedom from reoperation 96%, with only 1 reoperation among the 16 repairs. Mitral valve pathophysiology and morphology differ between Marfan and myxomatous mitral valve diseases. Valve repair in Marfan patients is durable and gives acceptable long-term results, even in adults who present with advanced mitral valve pathology. With increasing use of the modified David reimplantation operation and sparing of the aortic valve, mitral valve repair is a greater imperative, particularly since we have not had to reoperate on any Marfan patients with reimplantations.

  9. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  10. The Klinger hot gas double axial valve

    International Nuclear Information System (INIS)

    Kruschik, J.; Hiltgen, H.

    1984-01-01

    The Klinger hot gas valve is a medium controlled double axial valve with advanced design features and safety function. It was first proposed by Klinger early in 1976 for the PNP-Project as a containment shut-off for hot helium (918 deg. C and 42 bar), because a market research has shown that such a valve is not state of present techniques. In the first stage of development a feasibility study had to be made by detailed design, calculation and by basic experiments for key components in close collaboration with Interatom/GHT. This was the basis for further design, calculation, construction and experimental work for such a valve prototype within the new development contract. The stage of knowledge to that time revealed the following key priority development areas: Finite element stress analysis for the highly stressed high temperature main components; development of an insulation layout; Detailed experimental tests of functionally important structural components or units of the valve, partly at Klingers (gasstatic bearings, flexible metallic sealing element, aerodynamic and thermohydraulic tests), partly at Interatom (actuator unit and also gasstatic bearings), partly at HRB in Juelich (flexible metallic sealing system, aerodynamic and thermohydraulic tests); Design of a test valve for experimental work in the KVK (test circuit at Interatom) for evaluation of temperature distribution and reliability of operation; Design of a prototype and extensive testing in the KVK

  11. Synthetic imaging diagnosis of valvular heart diseases (especially, mytral valve), for the most part of angled projections in cineangiocardiographic study

    International Nuclear Information System (INIS)

    Katabuchi, Tetsuro; Wakamatsu, Takashi; Nakayama, Kazuhiko

    1981-01-01

    Recently, owing to developments of high output X-ray tube, high resolution image intensifier and mobile U or C arm, increasing remarkably, has been application of cinegraphy to angiocardiographic study. Surgical treatments for heart diseases have been very advanced in this few years, so that before operation, is demanded to precise anatomically and functionally diagnosis of them. In this paper, are discussed cineangiocardiography, echocardiography, in regard to the most useful investigation of valvelar heart diseases and some problems of imaging techniques, finally, introduced the newest examination method of diagnostic imaging. (author)

  12. A 29-Year-Old Harken Disk Mitral Valve

    Science.gov (United States)

    Hsi, David H.; Ryan, Gerald F.; Taft, Janice; Arnone, Thomas J.

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patient's 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features. (Tex Heart Inst J 2003;30:319–21) PMID:14677746

  13. Mitral valve prolapse and hyperthyroidism: effect of patient selection.

    Science.gov (United States)

    Zullo, M A; Devereux, R B; Kramer-Fox, R; Lutas, E M; Brown, W T

    1985-11-01

    Patients with mitral valve prolapse and hyperthyroidism have common symptoms; the most outstanding symptom is palpitation. To determine whether or not common symptoms contributed to the reported association of these conditions, we evaluated 220 patients with symptomatic mitral valve prolapse and 216 first-degree relatives in 72 families; 65 relatives with mitral valve prolapse and 151 relatives without mitral valve prolapse, all greater than or equal to 16 years of age. Thirty subjects, aged 49 +/- 13 years (p less than 0.025 vs entire study group), had thyroid disease (23 subjects had definite thyroid disease, seven subjects had probable); 27 of 30 subjects with thyroid disease (90%) were female (p less than 0.005). The age- and sex-adjusted prevalence of hyperthyroidism was significantly higher in probands with mitral valve prolapse than in family members without mitral valve prolapse (3.5% vs 0%, p = 0.03), while an intermediate prevalence of hyperthyroidism (2.2%) was observed in family members with mitral valve prolapse. Thus, the prevalence of hyperthyroidism is increased among symptomatic patients with mitral valve prolapse as compared to family members without mitral valve prolapse, but the prevalence of thyroid conditions is similar among family members with or without this condition. These findings are explained by the effect of common symptoms on clinical detection of both mitral valve prolapse and hyperthyroidism.

  14. Ventricular perforation as a complication of percutaneous valve ...

    African Journals Online (AJOL)

    Aortic stenosis (AS) is the most commonly encountered valvular disease in developed countries. Once symptomatic, this disease carries a dismal prognosis. Patients unfit for surgical valve replacement may require transcatheter aortic valve implantations (TAVI). We present a complication of this novel approach where a ...

  15. Experimental Models of Inherited PrP Prion Diseases.

    Science.gov (United States)

    Watts, Joel C; Prusiner, Stanley B

    2017-11-01

    The inherited prion protein (PrP) prion disorders, which include familial Creutzfeldt-Jakob disease, Gerstmann-Sträussler-Scheinker disease, and fatal familial insomnia, constitute ∼10%-15% of all PrP prion disease cases in humans. Attempts to generate animal models of these disorders using transgenic mice expressing mutant PrP have produced variable results. Although many lines of mice develop spontaneous signs of neurological illness with accompanying prion disease-specific neuropathological changes, others do not. Furthermore, demonstrating the presence of protease-resistant PrP species and prion infectivity-two of the hallmarks of the PrP prion disorders-in the brains of spontaneously sick mice has proven particularly challenging. Here, we review the progress that has been made toward developing accurate mouse models of the inherited PrP prion disorders. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.

  16. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  18. SOLA-LOOP analysis of a back pressure check valve

    International Nuclear Information System (INIS)

    Travis, J.R.

    1984-01-01

    The SOLA-LOOP computer code for transient, nonequilibrium, two-phase flows in networks has been coupled with a simple valve model to analyze a feedwater pipe breakage with a back-pressure check valve. Three tests from the Superheated Steam Reactor Safety Program Project (PHDR) at Kahl, West Germany, are analyzed, and the calculated transient back-pressure check valve behavior and fluid dynamics effects are found to be in excellent agreement with the experimentally measured data

  19. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  20. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  1. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  2. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  3. Progression of experimental chronic Aleutian mink disease virus infection

    DEFF Research Database (Denmark)

    Jensen, Trine Hammer; Chriél, Mariann; Hansen, Mette Sif

    2016-01-01

    Aleutian mink disease virus (AMDV) is found world-wide and has a major impact on mink health and welfare by decreasing reproduction and fur quality. In the majority of mink, the infection is subclinical and the diagnosis must be confirmed by serology or polymerase chain reaction (PCR). Increased ...

  4. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  5. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  6. ORGANIC TRICUSPID VALVE REPAIR WITH AUTOLOGOUS GLUTARALDEHYDE FIXED PERICARDIAL PATCH : A SINGLE CENTER RESULTS

    Directory of Open Access Journals (Sweden)

    Murtaza A

    2015-10-01

    Full Text Available AIM AND OBJECTIVE: The aim of this study was to determine the effectiveness and results of repair of Organic Tricuspid Valve disease. INTRODUCTION : since tricuspid valve disease most often found in association with other valve disease. Isolated tricuspid valve disease is ra re. Pattern of involvement of tricuspid valve disease shows functional (75% and primary (organic in (25%. Surgical repair of organic tricuspid valve disease often fails because of abnormal valve. This usually leads to limited options. This study examine s our experience of tricuspid valve repair with autologous pericardium for organic tricuspid valve disease. MATERIAL AND METHODS : From Jan 2014 to May 2015, 22 patients underwent repairs for organic tricuspid valve disease. The patient aged 15 to 65 years and all were in New York Heart Association (NYHA class of III or IV. All patients presented with severe tricuspid disease coexisting with other cardiac pathology, usually left - sided heart valve disease. Repair techniques included Commisurotomy, division o f secondary chordae, Glutaraldehyde treated autologous pericardial patch augmentation of tricuspid valve leaflets, anterior papillary muscle advancement etc with or without ring/suture annuloplasty. Follow - up duration was 3 to 18 months. RESULTS : No deaths or late reoperations occurred. All patients demonstrated clinical improvements on follow up. Echocardiographic studies before hospital discharge showed less than mild tricuspid regurgitation in all patients except one. CONCLUSIONS : Large majorit y of organic tricuspid valve regurgitation is repairable with acceptable early results. Tricuspid stenosis and mixed tricuspid valve disease are more challenging. In the latter group, it is a judgment call whether to accept a suboptimal result or replace t he valve

  7. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  8. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  9. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  10. Gender hormones and the progression of experimental polycystic kidney disease.

    Science.gov (United States)

    Stringer, Kenneth D; Komers, Radko; Osman, Shukri A; Oyama, Terry T; Lindsley, Jessie N; Anderson, Sharon

    2005-10-01

    Male gender is a risk factor for progression of autosomal-dominant polycystic kidney disease (ADPKD), clinically and in the Han:SPRD rat model. Orchiectomy limits progression, but mechanisms of the detrimental effect of androgen, and/or beneficial effects of estrogen, are not known. This protocol tested the hypothesis that male gender (intact androgen status) promotes progression, while female gender (intact estrogen status) is protective; and that these disease-modifying effects are due to changes in expression of known fibrotic mediators. Studies were performed in male and female noncystic control (+/+) and cystic (+/-) rats subjected to orchiectomy, ovariectomy, or sham operation. At 12 weeks of age, renal function was measured. Blood and kidneys were taken for measurement of plasma and renal renin, endothelin (ET-1), endothelial nitric oxide synthase (eNOS), and vascular endothelial growth factor (VEGF), using biochemical, protein expression, and immunohistochemical methods. Cystic male rats exhibited significantly reduced glomerular filtration (GFR) and effective renal plasma flow (ERPF) rates, with suppression of plasma and renal renin, up-regulation of renal ET-1 and eNOS, and down-regulation of renal VEGF expression. Orchiectomy attenuated the fall in GFR and ERPF, while numerically limiting changes in eNOS and VEGF. Female rats exhibited less cystic growth, with normal renin status, lesser elevation of renal ET-1, and proportionately lesser changes in VEGF and eNOS. Ovariectomy led to higher blood pressure and reduced GFR and ERPF, with a trend toward upregulation of ET-1, and significant down-regulation of VEGF and eNOS. Female gender is protective, but ovariectomy attenuates the protective effect of female gender, in association with changes in renal expression of ET-1, VEGF, and eNOS. The accelerated disease in male rats can be attenuated by orchiectomy and consequent changes in expression of disease mediators.

  11. Reduced cerebral vascularization in experimental neuronopathic Gaucher disease.

    Science.gov (United States)

    Smith, Nicholas Jc; Fuller, Maria; Saville, Jennifer T; Cox, Timothy M

    2018-01-01

    The glycosphingolipidosis, Gaucher disease, in which a range of neurological manifestations occur, results from a deficiency of acid β-glucocerebrosidase, with subsequent accumulation of β-glucocerebroside, its upstream substrates, and the non-acylated congener β-glucosylsphingosine. However, the mechanisms by which end-organ dysfunction arise are poorly understood. Here, we report strikingly diminished cerebral microvascular density in a murine model of disease, and provide a detailed analysis of the accompanying cerebral glycosphingolipidome in these animals, with marked elevations of β-glucosylsphingosine. Further in vitro studies confirmed a concentration-dependent impairment of endothelial cytokinesis upon exposure to quasi-pathological concentrations of β-glucosylsphingosine. These findings support a premise for pathogenic disruption of cerebral angiogenesis as an end-organ effect, with potential for therapeutic modulation in neuronopathic Gaucher disease. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  12. Current Experimental Studies of Gene Therapy in Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Jing-ya Lin

    2017-05-01

    Full Text Available Parkinson's disease (PD was characterized by late-onset, progressive dopamine neuron loss and movement disorders. The progresses of PD affected the neural function and integrity. To date, most researches had largely addressed the dopamine replacement therapies, but the appearance of L-dopa-induced dyskinesia hampered the use of the drug. And the mechanism of PD is so complicated that it's hard to solve the problem by just add drugs. Researchers began to focus on the genetic underpinnings of Parkinson's disease, searching for new method that may affect the neurodegeneration processes in it. In this paper, we reviewed current delivery methods used in gene therapies for PD, we also summarized the primary target of the gene therapy in the treatment of PD, such like neurotrophic factor (for regeneration, the synthesis of neurotransmitter (for prolong the duration of L-dopa, and the potential proteins that might be a target to modulate via gene therapy. Finally, we discussed RNA interference therapies used in Parkinson's disease, it might act as a new class of drug. We mainly focus on the efficiency and tooling features of different gene therapies in the treatment of PD.

  13. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    International Nuclear Information System (INIS)

    Gooley, Robert P.; Cameron, James D.; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T.

    2015-01-01

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  14. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  15. Short-term to Long-term Results of Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Yakin, Mehmet; Eksioglu, Umit; Sungur, Gulten; Satana, Banu; Demirok, Gulizar; Ornek, Firdevs

    2017-01-01

    To evaluate short-term to long-term outcomes of Ahmed glaucoma valve (AGV) implantation in the management of uveitic glaucoma (UG) secondary to Behçet disease (BD). A retrospective chart review of 47 eyes of 35 patients with UG secondary to BD who underwent AGV implantation was conducted. Success was defined as having an intraocular pressure (IOP) between 6 and 21 mm Hg with (qualified success) or without (complete success) antiglaucomatous medications and without need for further glaucoma surgery. Mean postoperative follow-up was 57.72±26.13 months. Mean preoperative IOP was 35.40±8.33 mm Hg versus 12.28±2.90 mm Hg at the last follow-up visit (P<0.001). Mean number of preoperative topical antiglaucomatous medications was 2.96±0.29 versus 0.68±1.12 at the last follow-up visit (P<0.001). In all eyes, IOP could be maintained between 6 and 21 mm Hg with or without antiglaucomatous medications during follow-up. The cumulative probability of complete success was 46.8% at 6 months, 40.4% at 12 months, and 35.9% at 36 months, and the cumulative probability of eyes without complication was 53.2% at 6 months, 46.5% at 12 months, and 39.6% at 24 months postoperatively based on Kaplan-Meier survival analysis. No persistent or irreparable complications were observed. This study includes one of the largest series of AGV implantation in the management of UG with the longest follow-up reported. AGV implantation can be considered as a primary surgical option in the management of UG secondary to BD with 100% total success rate (with or without medications).

  16. Short-term follow-up of exercise training program and beta-blocker treatment on quality of life in dogs with naturally acquired chronic mitral valve disease

    Directory of Open Access Journals (Sweden)

    M. Marcondes-Santos

    2015-01-01

    Full Text Available This study aimed to evaluate the effects of carvedilol treatment and a regimen of supervised aerobic exercise training on quality of life and other clinical, echocardiographic, and biochemical variables in a group of client-owned dogs with chronic mitral valve disease (CMVD. Ten healthy dogs (control and 36 CMVD dogs were studied, with the latter group divided into 3 subgroups. In addition to conventional treatment (benazepril, 0.3-0.5 mg/kg once a day, and digoxin, 0.0055 mg/kg twice daily, 13 dogs received exercise training (subgroup I; 10.3±2.1 years, 10 dogs received carvedilol (0.3 mg/kg twice daily and exercise training (subgroup II; 10.8±1.7 years, and 13 dogs received only carvedilol (subgroup III; 10.9±2.1 years. All drugs were administered orally. Clinical, laboratory, and Doppler echocardiographic variables were evaluated at baseline and after 3 and 6 months. Exercise training was conducted from months 3-6. The mean speed rate during training increased for both subgroups I and II (ANOVA, P>0.001, indicating improvement in physical conditioning at the end of the exercise period. Quality of life and functional class was improved for all subgroups at the end of the study. The N-terminal pro-brain natriuretic peptide (NT-proBNP level increased in subgroup I from baseline to 3 months, but remained stable after training introduction (from 3 to 6 months. For subgroups II and III, NT-proBNP levels remained stable during the entire study. No difference was observed for the other variables between the three evaluation periods. The combination of carvedilol or exercise training with conventional treatment in CMVD dogs led to improvements in quality of life and functional class. Therefore, light walking in CMVD dogs must be encouraged.

  17. Effect of pimobendan or benazepril hydrochloride on survival times in dogs with congestive heart failure caused by naturally occurring myxomatous mitral valve disease: the QUEST study.

    Science.gov (United States)

    Häggström, J; Boswood, A; O'Grady, M; Jöns, O; Smith, S; Swift, S; Borgarelli, M; Gavaghan, B; Kresken, J-G; Patteson, M; Ablad, B; Bussadori, C M; Glaus, T; Kovacević, A; Rapp, M; Santilli, R A; Tidholm, A; Eriksson, A; Belanger, M C; Deinert, M; Little, C J L; Kvart, C; French, A; Rønn-Landbo, M; Wess, G; Eggertsdottir, A V; O'Sullivan, M L; Schneider, M; Lombard, C W; Dukes-McEwan, J; Willis, R; Louvet, A; DiFruscia, R

    2008-01-01

    Myxomatous mitral valve disease (MMVD) continues to be an important cause of morbidity and mortality in geriatric dogs despite conventional therapy. Pimobendan in addition to conventional therapy will extend time to sudden cardiac death, euthanasia for cardiac reasons, or treatment failure when compared with conventional therapy plus benazepril in dogs with congestive heart failure (CHF) attributable to MMVD. Two hundred and sixty client-owned dogs in CHF caused by MMVD were recruited from 28 centers in Europe, Canada, and Australia. A prospective single-blinded study with dogs randomized to PO receive pimobendan (0.4-0.6 mg/kg/d) or benazepril hydrochloride (0.25-1.0 mg/kg/d). The primary endpoint was a composite of cardiac death, euthanized for heart failure, or treatment failure. Eight dogs were excluded from analysis. One hundred and twenty-four dogs were randomized to pimobendan and 128 to benazepril. One hundred and ninety dogs reached the primary endpoint; the median time was 188 days (267 days for pimobendan, 140 days for benazepril hazard ratio = 0.688, 95% confidence limits [CL]=0.516-0.916, P= .0099). The benefit of pimobendan persisted after adjusting for all baseline variables. A longer time to reach the endpoint was also associated with being a Cavalier King Charles Spaniel, requiring a lower furosemide dose, and having a higher creatinine concentration. Increases in several indicators of cardiac enlargement (left atrial to aortic root ratio, vertebral heart scale, and percentage increase in left ventricular internal diameter in systole) were associated with a shorter time to endpoint, as was a worse tolerance for exercise. Pimobendan plus conventional therapy prolongs time to sudden death, euthanasia for cardiac reasons, or treatment failure in dogs with CHF caused by MMVD compared with benazepril plus conventional therapy.

  18. Longitudinal analysis of quality of life, clinical, radiographic, echocardiographic, and laboratory variables in dogs with myxomatous mitral valve disease receiving pimobendan or benazepril: the QUEST study.

    Science.gov (United States)

    Häggström, J; Boswood, A; O'Grady, M; Jöns, O; Smith, S; Swift, S; Borgarelli, M; Gavaghan, B; Kresken, J-G; Patteson, M; Åblad, B; Bussadori, C M; Glaus, T; Kovačević, A; Rapp, M; Santilli, R A; Tidholm, A; Eriksson, A; Belanger, M C; Deinert, M; Little, C J L; Kvart, C; French, A; Rønn-Landbo, M; Wess, G; Eggertsdottir, A; Lynne O'Sullivan, M; Schneider, M; Lombard, C W; Dukes-McEwan, J; Willis, R; Louvet, A; DiFruscia, R

    2013-01-01

    Myxomatous mitral valve disease (MMVD) is an important cause of morbidity and mortality in dogs. To compare, throughout the period of follow-up of dogs that had not yet reached the primary endpoint, the longitudinal effects of pimobendan versus benazepril hydrochloride treatment on quality-of-life (QoL) variables, concomitant congestive heart failure (CHF) treatment, and other outcome variables in dogs suffering from CHF secondary to MMVD. A total of 260 dogs in CHF because of MMVD. A prospective single-blinded study with dogs randomized to receive pimobendan (0.4-0.6 mg/kg/day) or benazepril hydrochloride (0.25-1.0 mg/kg/day). Differences in outcome variables and time to intensification of CHF treatment were compared. A total of 124 dogs were randomized to pimobendan and 128 to benazepril. No difference was found between groups in QoL variables during the trial. Time from inclusion to 1st intensification of CHF treatment was longer in the pimobendan group (pimobendan 98 days, IQR 30-276 days versus benazepril 59 days, IQR 11-121 days; P = .0005). Postinclusion, dogs in the pimobendan group had smaller heart size based on VHS score (P = .013) and left ventricular diastolic (P = .035) and systolic (P = .0044) dimensions, higher body temperature (P = .030), serum sodium (P = .0027), and total protein (P = .0003) concentrations, and packed cell volume (P = .030). Incidence of arrhythmias was similar in treatment groups. Pimobendan versus benazepril resulted in similar QoL during the study, but conferred increased time before intensification of CHF treatment. Pimobendan treatment resulted in smaller heart size, higher body temperature, and less retention of free water. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  19. MicroRNAs Clustered within the 14q32 Locus Are Associated with Endothelial Damage and Microparticle Secretion in Bicuspid Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Neus Martínez-Micaelo

    2017-09-01

    Full Text Available Background: We previously described that PECAM+ circulating endothelial microparticles (EMPs are elevated in bicuspid aortic valve (BAV disease as a manifestation of endothelial damage. In this study, we hypothesized that this endothelial damage, is functionally related to the secretion of a specific pattern of EMP-associated miRNAs.Methods: We used a bioinformatics approach to correlate the PECAM+ EMP levels with the miRNA expression profile in plasma in healthy individuals and BAV patients (n = 36. In addition, using the miRNAs that were significantly associated with PECAM+ EMP levels, we inferred a miRNA co-expression network using a Gaussian graphical modeling approach to identify highly co-expressed miRNAs or miRNA clusters whose expression could functionally regulate endothelial damage.Results: We identified a co-expression network composed of 131 miRNAs whose circulating expression was significantly associated with PECAM+ EMP levels. Using a topological analysis, we found that miR-494 was the most important hub within the co-expression network. Furthermore, through positional gene enrichment analysis, we identified a cluster of 19 highly co-expressed miRNAs, including miR-494, that was located in the 14q32 locus on chromosome 14 (p = 1.9 × 10−7. We evaluated the putative biological role of this miRNA cluster by determining the biological significance of the genes targeted by the cluster using functional enrichment analysis. We found that this cluster was involved in the regulation of genes with various functions, specifically the “cellular nitrogen compound metabolic process” (p = 2.34 × 10−145, “immune system process” (p = 2.57 × 10−6, and “extracellular matrix organization” (p = 8.14 × 10−5 gene ontology terms and the “TGF-β signaling pathway” KEGG term (p = 2.59 × 10−8.Conclusions: Using an integrative bioinformatics approach, we identified the circulating miRNA expression profile associated with

  20. MicroRNAs Clustered within the 14q32 Locus Are Associated with Endothelial Damage and Microparticle Secretion in Bicuspid Aortic Valve Disease

    Science.gov (United States)

    Martínez-Micaelo, Neus; Beltrán-Debón, Raúl; Aragonés, Gerard; Faiges, Marta; Alegret, Josep M.

    2017-01-01

    Background: We previously described that PECAM+ circulating endothelial microparticles (EMPs) are elevated in bicuspid aortic valve (BAV) disease as a manifestation of endothelial damage. In this study, we hypothesized that this endothelial damage, is functionally related to the secretion of a specific pattern of EMP-associated miRNAs. Methods: We used a bioinformatics approach to correlate the PECAM+ EMP levels with the miRNA expression profile in plasma in healthy individuals and BAV patients (n = 36). In addition, using the miRNAs that were significantly associated with PECAM+ EMP levels, we inferred a miRNA co-expression network using a Gaussian graphical modeling approach to identify highly co-expressed miRNAs or miRNA clusters whose expression could functionally regulate endothelial damage. Results: We identified a co-expression network composed of 131 miRNAs whose circulating expression was significantly associated with PECAM+ EMP levels. Using a topological analysis, we found that miR-494 was the most important hub within the co-expression network. Furthermore, through positional gene enrichment analysis, we identified a cluster of 19 highly co-expressed miRNAs, including miR-494, that was located in the 14q32 locus on chromosome 14 (p = 1.9 × 10−7). We evaluated the putative biological role of this miRNA cluster by determining the biological significance of the genes targeted by the cluster using functional enrichment analysis. We found that this cluster was involved in the regulation of genes with various functions, specifically the “cellular nitrogen compound metabolic process” (p = 2.34 × 10−145), “immune system process” (p = 2.57 × 10−6), and “extracellular matrix organization” (p = 8.14 × 10−5) gene ontology terms and the “TGF-β signaling pathway” KEGG term (p = 2.59 × 10−8). Conclusions: Using an integrative bioinformatics approach, we identified the circulating miRNA expression profile associated with secreted PECAM

  1. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  2. Bentall and De Bono surgery for correction of valve and ascending aortic disease: long-term results.

    Science.gov (United States)

    Silva, Virgílio Figueiredo; Real, Daniel Sundfeld Spiga; Branco, João Nelson Rodrigues; Catani, Roberto; Kim, Hyong Chun; Buffolo, Enio; Fonseca, José Honório de Almeida Palma da

    2008-01-01

    A retrospective study was performed in a series of consecutive patients who underwent a Bentall and De Bono procedure. Data were removed of medical records and follow-up data were obtained from clinical records and direct contact with patients. A total of 39 patients were studied between January 1996 and December 2005. The median age was 47 years (range 14-70). There were 33 males and six females. Eleven (25.5%) patients presented Marfan syndrome and one (2.5%) Turner syndrome. Nineteen (48.5%) patients had hypertension, eight (20.5%) had history of smoking, six (15.5%) had history of alcoholism, eight (20.5%) had dyslipidemia, two (5.0%) had diabetes and one (2.56%) had myocardial infarct previously. Twenty-eight (72%) patients were in II-III NYHA class in the moment of the surgery. Annulo-aortic ecstasy was present in 14 (35.9%) patients and aortic aneurysms in 16 (41%). The median time in intensive care unit was 8.79 days with range 2-23 days. Four (10.0%) patients underwent an emergency operation and 35 (90%) elective. The overall hospital mortality was 5% (2/39). The event-free survival is 94.87% at 1 year and 84.61% at in 5 and 10. The median time of follow-up was 46.5 months (range 14-120 months). The Bentall and De Bono technique obtained excellent results in the short-term and long-term, which support the continued use of the compositive graft technique as the preferred method of treatment for patients with aortic root disease. Our findings confirm the current literature data.

  3. Development of Overflow-Prevention Valve with Trigger Mechanism.

    Science.gov (United States)

    Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya

    2016-09-01

    A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.

  4. Development of Proportional Pressure Control Valve for Hydraulic Braking Actuator of Automobile ABS

    Directory of Open Access Journals (Sweden)

    Che-Pin Chen

    2018-04-01

    Full Text Available This research developed a novel proportional pressure control valve for an automobile hydraulic braking actuator. It also analyzed and simulated solenoid force of the control valves, and the pressure relief capability test of electromagnetic thrust with the proportional valve body. Considering the high controllability and ease of production, the driver of this proportional valve was designed with a small volume and powerful solenoid force to control braking pressure and flow. Since the proportional valve can have closed-loop control, the proportional valve can replace a conventional solenoid valve in current brake actuators. With the proportional valve controlling braking and pressure relief mode, it can narrow the space of hydraulic braking actuator, and precisely control braking force to achieve safety objectives. Finally, the proposed novel proportional pressure control valve of an automobile hydraulic braking actuator was implemented and verified experimentally.

  5. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  6. Experimental Treatment of Ebola Virus Disease with Brincidofovir.

    Directory of Open Access Journals (Sweden)

    Jake Dunning

    Full Text Available The nucleotide analogue brincidofovir was developed to prevent and treat infections caused by double-stranded DNA viruses. Based on in vitro data suggesting an antiviral effect against Ebola virus, brincidofovir was included in the World Health Organisation list of agents that should be prioritised for clinical evaluation in patients with Ebola virus disease (EVD during the West African epidemic.In this single-arm phase 2 trial conducted in Liberia, patients with laboratory-confirmed EVD (two months of age or older, enrolment bodyweight ≥50 kg received oral brincidofovir 200 mg as a loading dose on day 0, followed by 100 mg brincidofovir on days 3, 7, 10, and 14. Bodyweight-adjusted dosing was used for patients weighing <50 kg at enrolment. The primary outcome was survival at Day 14 after the first dose of brincidofovir. Four patients were enrolled between 01 January 2015 and 31 January 2015. The trial was stopped following the decision by the manufacturer to terminate their program of development of brincidofovir for EVD. No Serious Adverse Reactions or Suspected Unexpected Serious Adverse Reactions were identified. All enrolled subjects died of an illness consistent with EVD.Due to the small sample size it was not possible to determine the efficacy of brincidofovir for the treatment of EVD. The premature termination of the trial highlights the need to establish better practices for preclinical in-vitro and animal screening of therapeutics for potentially emerging epidemic infectious diseases prior to their use in patients.Pan African Clinical Trials Registry PACTR201411000939962.

  7. Development of multilayer piezoelectric actuator valve for JT-60

    International Nuclear Information System (INIS)

    Miyo, Yasuhiko; Hiratsuka, Hajime; Masui, Hiroshi; Hosogane, Nobuyuki; Miya, Naoyuki

    2001-11-01

    In order to improve the gas injection valve used for the operation of JT-60, a new type of valve (multilayer piezoelectric actuator valve) was developed. The conventional valve (bimorph piezoelectric valve) has been used for 15 years since the beginning of experimental operation in April, 1985. However, it came to be hard to keep the performance of the valve because of the deterioration of the driving source, i.e. piezoelectric element. Developments of the new valve were carried out based on experiences through experimental operations in JT-60. Requirements for the design are: (1) to be hard structure for making a sheet leak, (2) to allow a repair work at atmosphere side without an air vent of the vacuum vessel, (3) to be more smaller and lighter compared with the conventional one, and (4) to have a high maintenance efficiency by utilizing of the commercial piezoelectric elements and power supplies. The newly developed valve was examined with various tests such as gas flow characteristic test, high magnetic field proof test, high temperature proof test and gas flow rate test for aged deterioration. Results, confirm that the performance of the valve is applicable for JT-60 operations. (author)

  8. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  10. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  11. Resveratrol Ameliorates Experimental Alcoholic Liver Disease by Modulating Oxidative Stress

    Directory of Open Access Journals (Sweden)

    He Peiyuan

    2017-01-01

    Full Text Available The aim of this study was to investigate the hepatoprotective effects of resveratrol in alcoholic liver disease (ALD. Alcohol was administered to healthy female rats starting from 6% (v/v and gradually increased to 20% (v/v by the fifth week. After 16 weeks of intervention, liver enzymes (aspartate aminotransferase [AST] and alanine aminotransferase [ALT] were analyzed using a chemistry analyzer, while hepatic antioxidant enzymes, oxidative stress markers, and caspase 3 activity were assessed using ELISA kits. Furthermore, hepatic CYP2E1 protein levels and mRNA levels of antioxidant and inflammation-related genes were determined using western blotting and RT-PCR, respectively. The results showed that resveratrol significantly attenuated alcohol-induced elevation of liver enzymes and improved hepatic antioxidant enzymes. Resveratrol also attenuated alcohol-induced CYP2E1 increase, oxidative stress, and apoptosis (caspase 3 activity. Moreover, genes associated with oxidative stress and inflammation were regulated by resveratrol supplementation. Taken together, the results suggested that resveratrol alleviated ALD through regulation of oxidative stress, apoptosis, and inflammation, which was mediated at the transcriptional level. The data suggests that resveratrol is a promising natural therapeutic agent against chronic ALD.

  12. Long Pentraxin 3: Experimental and Clinical Relevance in Cardiovascular Diseases

    Directory of Open Access Journals (Sweden)

    Fabrizia Bonacina

    2013-01-01

    Full Text Available Pentraxin 3 (PTX3 is an essential component of the humoral arm of innate immunity and belongs, together with the C-reactive protein (CRP and other acute phase proteins, to the pentraxins' superfamily: soluble, multifunctional, pattern recognition proteins. Pentraxins share a common C-terminal pentraxin domain, which in the case of PTX3 is coupled to an unrelated long N-terminal domain. PTX3 in humans, like CRP, correlates with surrogate markers of atherosclerosis and is independently associated with the risk of developing vascular events. Studies addressing the potential physiopathological role of CRP in the cardiovascular system were so far inconclusive and have been limited by the fact that the sequence and regulation have not been conserved during evolution between mouse and man. On the contrary, the conservation of sequence, gene organization, and regulation of PTX3 supports the translation of animal model findings in humans. While PTX3 deficiency is associated with increased inflammation, cardiac damage, and atherosclerosis, the overexpression limits carotid restenosis after angioplasty. These observations point to a cardiovascular protective effect of PTX3 potentially associated with the ability of tuning inflammation and favor the hypothesis that the increased levels of PTX3 in subjects with cardiovascular diseases may reflect a protective physiological mechanism, which correlates with the immunoinflammatory response observed in several cardiovascular disorders.

  13. Imaging of aortic valve dynamics in 4D OCT

    Directory of Open Access Journals (Sweden)

    Schnabel Christian

    2015-09-01

    Full Text Available The mechanical components of the heart, especially the valves and leaflets, are enormous stressed during lifetime. Therefore, those structures undergo different pathophysiological tissue transformations which affect cardiac output and in consequence living comfort of affected patients. These changes may lead to calcific aortic valve stenosis (AVS, the major heart valve disease in humans. The knowledge about changes of the dynamic behaviour during the course of this disease and the possibility of early stage diagnosis is of particular interest and could lead to the development of new treatment strategies and drug based options of prevention or therapy. 4D optical coherence tomography (OCT in combination with high-speed video microscopy were applied to characterize dynamic behaviour of the murine aortic valve and to characterize dynamic properties during artificial stimulation. We present a promising tool to investigate the aortic valve dynamics in an ex vivo disease model with a high spatial and temporal resolution using a multimodal imaging setup.

  14. Prior oral conditions in patients undergoing heart valve surgery.

    Science.gov (United States)

    Silvestre, Francisco-Javier; Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-11-01

    Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Significant differences in bacterial plaque index were observed between the two groups ( p <0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls ( p <0.01). Sixty percent of the patients with valve disease presented periodontitis. Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words: Valve disease, aortic, mitral, heart surgery, periodontitis.

  15. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Should patients with Björk-Shiley valves undergo prophylactic replacement?

    Science.gov (United States)

    Birkmeyer, J D; Marrin, C A; O'Connor, G T

    1992-08-29

    About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that

  17. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery.

    Science.gov (United States)

    Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong

    2017-01-01

    Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  19. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  20. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  1. Piezogenic pedal papules with mitral valve prolapse

    Directory of Open Access Journals (Sweden)

    Cihan Altin

    2016-01-01

    Full Text Available Piezogenic pedal papules (PPP are herniations of subcutaneous adipose tissue into the dermis. PPP are skin-colored to yellowish papules and nodules on lateral surfaces of feet that typically become apparent when the patient stands flat on his/her feet. Some connective tissue diseases and syndromes have been reported in association with PPP. Mitral valve prolapse (MVP is a myxomatous degeneration of the mitral valve, characterized by the displacement of an abnormally thickened mitral valve leaflet into the left atrium during systole. MVP may be isolated or part of a heritable connective tissue disorder. PPP, which is generally considered as an isolated lesion, might be also a predictor of some cardiac diseases associated with connective tissue abnormalities such as MVP. A detailed systemic investigation including cardiac examination should be done in patients with PPP. Since in the literature, there are no case reports of association of PPP with MVP, we report these cases.

  2. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  3. Strategies, models and biomarkers in experimental non-alcoholic fatty liver disease research

    Science.gov (United States)

    Willebrords, Joost; Pereira, Isabel Veloso Alves; Maes, Michaël; Yanguas, Sara Crespo; Colle, Isabelle; Van Den Bossche, Bert; Da silva, Tereza Cristina; Oliveira, Cláudia P; Andraus, Wellington; Alves, Venâncio Avancini Ferreira; Cogliati, Bruno; Vinken, Mathieu

    2015-01-01

    Non-alcoholic fatty liver disease encompasses a spectrum of liver diseases, including simple steatosis, steatohepatitis, liver fibrosis and cirrhosis and hepatocellular carcinoma. Non-alcoholic fatty liver disease is currently the most dominant chronic liver disease in Western countries due to the fact that hepatic steatosis is associated with insulin resistance, type 2 diabetes mellitus, obesity, metabolic syndrome and drug-induced injury. A variety of chemicals, mainly drugs, and diets is known to cause hepatic steatosis in humans and rodents. Experimental non-alcoholic fatty liver disease models rely on the application of a diet or the administration of drugs to laboratory animals or the exposure of hepatic cell lines to these drugs. More recently, genetically modified rodents or zebrafish have been introduced as non-alcoholic fatty liver disease models. Considerable interest now lies in the discovery and development of novel non-invasive biomarkers of non-alcoholic fatty liver disease, with specific focus on hepatic steatosis. Experimental diagnostic biomarkers of non-alcoholic fatty liver disease, such as (epi)genetic parameters and ‘-omics’-based read-outs are still in their infancy, but show great promise. . In this paper, the array of tools and models for the study of liver steatosis is discussed. Furthermore, the current state-of-art regarding experimental biomarkers such as epigenetic, genetic, transcriptomic, proteomic and metabonomic biomarkers will be reviewed. PMID:26073454

  4. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  5. Reactor containment purge and vent valve performance experiments

    International Nuclear Information System (INIS)

    Hunter, J.A.; Steele, R.; Watkins, J.C.

    1985-01-01

    Three nuclear-designed butterfly valves typical of those used in domestic nuclear power plant containment purge and vent applications were tested. For a comparison of responses, two eight-inch nominal pipe size valves with differing internal design were tested. For extrapolation insights, a 24-inch nominal pipe size valve was also tested. The valve experiments were performed with various piping configurations and valve disc orientations to the flow, to simulate various installation options in field application. As a standard for comparing the effects of the installation options, testing was also performed in a standard ANSI test section. Test cycles were performed at inlet pressures of 5 to 60 psig, while monitoring numerous test parameters, such as the valve disc position, valve shaft torque, mass flow rate, and the pressure and temperature at multiple locations throughout the test section. An experimental data base was developed to assist in the evaluation of the current analytical methods and to determine the influence of inlet pressure, inlet duct geometry, and valve orientation to the flow media on valve torque requirements, along with any resulting limitations to the extrapolation methods. 2 refs., 15 figs

  6. A high performance magnetorheological valve with a meandering flow path

    International Nuclear Information System (INIS)

    Imaduddin, Fitrian; Amri Mazlan, Saiful; Azizi Abdul Rahman, Mohd; Zamzuri, Hairi; Ubaidillah; Ichwan, Burhanuddin

    2014-01-01

    The huge developments in the field of magnetorheological (MR) fluid-based devices will have a great influence on the future of mechatronic applications due to the ease of interfacing between electronic controls and the mechanical components that they provide. Among various MR fluid-based devices, an MR valve would be particularly significant for the development of other devices, if it could be successfully achieved. One of the most challenging obstacles to MR valve development is the difficulty of achieving device miniaturization while, at the same time, improving the achievable performance. This study demonstrates a novel design for an MR valve, using the meandering flow path approach in order to increase the effective area so that the MR fluid can be regulated within a small-sized valve. The meandering flow path is formed by combining multiple annular, radial and orifice flow channels. In order to analyze the valve performance, a mathematical model of the proposed MR valve is derived and combined with numerical simulation using the finite element method, with the intention of predicting the achievable pressure drop that can be generated by the valve. The predicted MR valve performances are then experimentally evaluated using an oscillation-disturbed bypass hydraulic cylinder. The simulation results show that the proposed MR valve design could yield substantial pressure drop improvement, which is confirmed by the experiment

  7. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  8. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Time-resolved PIV technique for high temporal resolution measurement of mechanical prosthetic aortic valve fluid dynamics.

    Science.gov (United States)

    Kaminsky, R; Morbiducci, U; Rossi, M; Scalise, L; Verdonck, P; Grigioni, M

    2007-02-01

    Prosthetic heart valves (PHVs) have been used to replace diseased native valves for more than five decades. Among these, mechanical PHVs are the most frequently implanted. Unfortunately, these devices still do not achieve ideal behavior and lead to many complications, many of which are related to fluid mechanics. The fluid dynamics of mechanical PHVs are particularly complex and the fine-scale characteristics of such flows call for very accurate experimental techniques. Adequate temporal resolution can be reached by applying time-resolved PIV, a high-resolution dynamic technique which is able to capture detailed chronological changes in the velocity field. The aim of this experimental study is to investigate the evolution of the flow field in a detailed time domain of a commercial bileaflet PHV in a mock-loop mimicking unsteady conditions, by means of time-resolved 2D Particle Image Velocimetry (PIV). The investigated flow field corresponded to the region immediately downstream of the valve plane. Spatial resolution as in "standard" PIV analysis of prosthetic valve fluid dynamics was used. The combination of a Nd:YLF high-repetition-rate double-cavity laser with a high frame rate CMOS camera allowed a detailed, highly temporally resolved acquisition (up to 10000 fps depending on the resolution) of the flow downstream of the PHV. Features that were observed include the non-homogeneity and unsteadiness of the phenomenon and the presence of large-scale vortices within the field, especially in the wake of the valve leaflets. Furthermore, we observed that highly temporally cycle-resolved analysis allowed the different behaviors exhibited by the bileaflet valve at closure to be captured in different acquired cardiac cycles. By accurately capturing hemodynamically relevant time scales of motion, time-resolved PIV characterization can realistically be expected to help designers in improving PHV performance and in furnishing comprehensive validation with experimental data

  10. Dry product valve

    International Nuclear Information System (INIS)

    Greaves, James D.

    1984-01-01

    This invention provides a system for delivering particulate radioactive or other toxic wastes to a container in which they can be solidified. The system includes a set of valves that prevent the escape of dusty materials to the atmosphere

  11. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  12. Valve for gas centrifuges

    Science.gov (United States)

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  13. Degenerative processes in bioprosthetic mitral valves in juvenile pigs

    Directory of Open Access Journals (Sweden)

    Pedersen Torben B

    2011-05-01

    Full Text Available Abstract Background Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00 and 1.20 (SD = ±0.25, respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55 and 6.51 mmHg (SD = ±2.57, respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.

  14. Modified conduit preparation creates a pseudosinus in an aortic valve-sparing procedure for aneurysm of the ascending aorta.

    Science.gov (United States)

    Cochran, R P; Kunzelman, K S; Eddy, A C; Hofer, B O; Verrier, E D

    1995-06-01

    Mechanical valved conduit replacement of the aortic root is a durable and appropriate procedure for many diseases of the ascending aorta, but may sacrifice an anatomically salvageable aortic valve. For young active patients and for patients with "systemic" arterial disease (atherosclerosis, Marfan's syndrome) who may require future operations, life-long anticoagulation with its attendant thromboembolic versus hemorrhagic risks is not ideal. Several techniques have been suggested as aortic valve-sparing options. Recently, a procedure was described that combines the freehand homograft techniques with the standard Bentall techniques (David procedure). This innovative technique replaces the ascending aorta with a Dacron cylinder, spares the aortic valve, and restores competence and thus offers an excellent alternative. The durability of this procedure that places the aortic valve inside a cylindrical conduit without sinuses of Valsalva is unknown. In selected patients, we have used this technique to spare the aortic valve. On the basis of experimental data and preliminary computer modeling, with the hope of improving the durability, we have modified the conduit to create a "pseudosinus" in our most recent nine patients. We have done the David procedure in 10 patients. The pseudosinus modification was done in the most recent nine patients. Patients' ages ranged from 37 to 71 years (mean 49.9 years). There were five female and five male patients. Five patients had Marfan's syndrome and five patients had annuloaortic ectasia. There has been no mortality and all patients have had both early and late follow-up echocardiography. Five patients have zero to trace aortic insufficiency, four patients have trace to mild aortic insufficiency, and one patient has mild or "1+" aortic insufficiency. Aortic insufficiency has not progressed in any patient during the 18 months of follow-up. The patient with 1+ aortic insufficiency has no activity limits, good ventricular function, and

  15. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    Science.gov (United States)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  16. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  17. Flow induced vibration of the large-sized sodium valve for MONJU

    International Nuclear Information System (INIS)

    Sato, K.

    1977-01-01

    Measurements have been made on the hydraulic characteristics of the large-sized sodium valves in the hydraulic simulation test loop with water as fluid. The following three prototype sodium valves were tested; (1) 22-inch wedge gate type isolation valve, (2) 22-inch butterfly type isolation valve, and (3) 16-inch butterfly type control valve. In the test, accelerations of flow induced vibrations were measured as a function of flow velocity and disk position. The excitation mechanism of the vibrations is not fully interpreted in these tests due to the complexity of the phenomena, but the experimental results suggest that it closely depends on random pressure fluctuations near the valve disk and flow separation at the contracted cross section between the valve seat and the disk. The intensity of flow induced vibrations suddenly increases at a certain critical condition, which depends on the type of valve and is proportional to fluid velocity. (author)

  18. Flow induced vibration of the large-sized sodium valve for MONJU

    Energy Technology Data Exchange (ETDEWEB)

    Sato, K [Sodium Engineering Division, O-arai Engineering Centre, Power Reactor and Nuclear Fuel Development Corporation, Nariata-cho, O-arai Machi, Ibaraki-ken (Japan)

    1977-12-01

    Measurements have been made on the hydraulic characteristics of the large-sized sodium valves in the hydraulic simulation test loop with water as fluid. The following three prototype sodium valves were tested; (1) 22-inch wedge gate type isolation valve, (2) 22-inch butterfly type isolation valve, and (3) 16-inch butterfly type control valve. In the test, accelerations of flow induced vibrations were measured as a function of flow velocity and disk position. The excitation mechanism of the vibrations is not fully interpreted in these tests due to the complexity of the phenomena, but the experimental results suggest that it closely depends on random pressure fluctuations near the valve disk and flow separation at the contracted cross section between the valve seat and the disk. The intensity of flow induced vibrations suddenly increases at a certain critical condition, which depends on the type of valve and is proportional to fluid velocity. (author)

  19. Compact UHV valve with field replaceable windows

    International Nuclear Information System (INIS)

    Johnson, E.D.; Freeman, J.; Powell, F.

    1991-01-01

    There are many applications in synchrotron radiation research where window valves can be usefully employed. Examples include gas cells for monochromator calibration, filters for high order light rejection, and as vacuum isolation elements between machine and experimental vacua. Often these devices are fairly expensive, and have only fixed (ie non-removable) windows. The development of a new type of seal technology by VAT for their series 01 valves provides a gate surface which is free from obstructions due to internal mechanical elements. This feature allows a threaded recess to be machined into the gate to receive a removable window frame which can carry standard size Luxel thin film windows. The combination of these features results in a DN 40 (2.75in. conflat flange) valve which provides a clear aperture of 21mm diameter for the window material. 8 refs., 2 figs

  20. Development and Characterization a Single-Active-Chamber Piezoelectric Membrane Pump with Multiple Passive Check Valves.

    Science.gov (United States)

    Zhang, Ronghui; You, Feng; Lv, Zhihan; He, Zhaocheng; Wang, Haiwei; Huang, Ling

    2016-12-12

    In order to prevent the backward flow of piezoelectric pumps, this paper presents a single-active-chamber piezoelectric membrane pump with multiple passive check valves. Under the condition of a fixed total number of passive check valves, by means of changing the inlet valves and outlet valves' configuration, the pumping characteristics in terms of flow rate and backpressure are experimentally investigated. Like the maximum flow rate and backpressure, the testing results show that the optimal frequencies are significantly affected by changes in the number inlet valves and outlet valves. The variation ratios of the maximum flow rate and the maximum backpressure are up to 66% and less than 20%, respectively. Furthermore, the piezoelectric pump generally demonstrates very similar flow rate and backpressure characteristics when the number of inlet valves in one kind of configuration is the same as that of outlet valves in another configuration. The comparison indicates that the backflow from the pumping chamber to inlet is basically the same as the backflow from the outlet to the pumping chamber. No matter whether the number of inlet valves or the number of outlet valves is increased, the backflow can be effectively reduced. In addition, the backpressure fluctuation can be significantly suppressed with an increase of either inlet valves or outlet valves. It also means that the pump can prevent the backflow more effectively at the cost of power consumption. The pump is very suitable for conditions where more accurate flow rates are needed and wear and fatigue of check valves often occur.

  1. The effect of insulin resistance on amygdale glucose metabolism alterations in experimental Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Ya. V. Gorina

    2017-01-01

    Full Text Available Purpose. Glucose metabolism is tightly regulated in the brain. Aberrant glucose metabolism is an important feature of neurodegenerative diseases, as inAlzheimer’s disease. The transport of glucose to the cell membrane is realized through the activity of insulin-regulated aminopeptidase (IRAP which controls transfer of glucose transporter to the plasma membrane. IRAP is considered as one of the key markers of insulin resistance in Alzheimer’s disease. However, the question of the mechanism of the action of the IRAP remains open. The aim of the study was to study the effect of IRAP expression on cells of the neuronal and glial lineage, glucose transporter (GLUT4 expression in the brain amygdala on emotional memory in animals with experimental Alzheimer’s disease.Materials and methods. The study was performed with two experimental models of Alzheimer’s disease in mice. The experimental group was mice of the CD1 line, males aged 4 months (Alzheimer’s disease model with the intra-hippocampal administration of beta-amyloid 1-42 (1 µl bilaterally in the CA1 area. The control group was mice of the CD1 line, males aged 4 months (sham-operated animals with the intrahippocampal administration of Phosphate buffered salin (1 µl bilaterally in the CA1. The genetic model of Alzheimer’s disease is the B6SLJ-Tg line mice (APPSwFlLon, PSEN1*M146L*L286V 6799Vas, males aged 4 months. The control group consisted of C57BL/6xSJL mice, males aged 4 months. Evaluation of emotional memory was carried out using “Fear conditioning” protocol. Expression of molecule-markers of insulin-resistance in the amygdala was studied by immunohistochemistry followed by confocal microscopy.Results. Aberrant associative learning and emotional memory was revealed in animals with an experimental model of Alzheimer’s disease. A decrease (p ≤ 0,05 of IRAP expression on cells of neuronal and glial nature, associated with GLUT4 down-regulation was detected in amygdala of

  2. Left-sided native valve Staphylococcus aureus endocarditis

    NARCIS (Netherlands)

    Slabbekoorn, M.; Horlings, H. M.; van der Meer, J. T. M.; Windhausen, A.; Van der Sloot, J. A. P.; Lagrand, W. K.

    2010-01-01

    Despite improved diagnostic tools and expanded treatment options, left-sided native valve endocarditis caused by Staphylococcus aureus infection remains a serious and destructive disease. The high morbidity and mortality, however, can be reduced by early recognition, correct diagnosis, and

  3. Sickle cell anemia and mitral valve replacement. Case report.

    Science.gov (United States)

    Bomfim, V; Ribeiro, A; Gouvea, F; Pereira, J; Björk, V

    1989-01-01

    An 8-year-old black boy with sickle cell disease and severe hemolytic anemia crisis (95% hemoglobin S) also had mitral incompetence due to rheumatic valve disease. A 27 mm monostrut Björk-Shiley valve prosthesis was implanted after partial exchange transfusions had reduced the hemoglobin S to less than 40%. High-flow normothermic perfusion was used during extracorporeal circulation, with care taken to avoid hypoxia and acidosis. Postoperative recovery was uneventful.

  4. Methods of estimation of mitral valve regurgitation for the cardiac surgeon

    Directory of Open Access Journals (Sweden)

    Baikoussis Nikolaos G

    2009-07-01

    Full Text Available Abstract Mitral valve regurgitation is a relatively common and important heart valve lesion in clinical practice and adequate assessment is fundamental to decision on management, repair or replacement. Disease localised to the posterior mitral valve leaflet or focal involvement of the anterior mitral valve leaflet is most amenable to mitral valve repair, whereas patients with extensive involvement of the anterior leaflet or incomplete closure of the valve are more suitable for valve replacement. Echocardiography is the recognized investigation of choice for heart valve disease evaluation and assessment. However, the technique is depended on operator experience and on patient's hemodynamic profile, and may not always give optimal diagnostic views of mitral valve dysfunction. Cardiac catheterization is related to common complications of an interventional procedure and needs a hemodynamic laboratory. Cardiac magnetic resonance (MRI seems to be a useful tool which gives details about mitral valve anatomy, precise point of valve damage, as well as the quantity of regurgitation. Finally, despite of its higher cost, cardiac MRI using cine images with optimized spatial and temporal resolution can also resolve mitral valve leaflet structural motion, and can reliably estimate the grade of regurgitation.

  5. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  6. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  7. How to use and integrate bioinformatics tools to compare proteomic data from distinct conditions? A tutorial using the pathological similarities between Aortic Valve Stenosis and Coronary Artery Disease as a case-study.

    Science.gov (United States)

    Trindade, Fábio; Ferreira, Rita; Magalhães, Beatriz; Leite-Moreira, Adelino; Falcão-Pires, Inês; Vitorino, Rui

    2018-01-16

    Nowadays we are surrounded by a plethora of bioinformatics tools, powerful enough to deal with the large amounts of data arising from proteomic studies, but whose application is sometimes hard to find. Therefore, we used a specific clinical problem - to discriminate pathophysiology and potential biomarkers between two similar cardiovascular diseases, aortic valve stenosis (AVS) and coronary artery disease (CAD) - to make a step-by-step guide through four bioinformatics tools: STRING, DisGeNET, Cytoscape and ClueGO. Proteome data was collected from articles available on PubMed centered on proteomic studies enrolling subjects with AVS or CAD. Through the analysis of gene ontology provided by STRING and ClueGO we could find specific biological phenomena associated with AVS, such as down-regulation of elastic fiber assembly, and with CAD, such as up-regulation of plasminogen activation. Moreover, through Cytoscape and DisGeNET we could pinpoint surrogate markers either for AVS (e.g. popeye domain containing protein 2 and 28S ribosomal protein S36, mitochondrial) or for CAD (e.g. ankyrin repeat and SOCS box protein 7) which deserve future validation. Data recycling and integration as well as research orientation are among the main advantages of resorting to bioinformatics analysis, hence these tutorials can be of great convenience for proteomics investigators. As we saw for aortic valve stenosis and coronary artery disease, it can be of great relevance to perform preliminary bioinformatics analysis with already published proteomics data. It not only saves us time in the lab (avoiding work duplication) as it points out new hypothesis to explain the phenotypical presentation of the diseases as well as new surrogate markers with clinical relevance, deserving future scrutiny. These essential steps can be easily overcome if one follows the steps proposed in our tutorial for STRING, DisGeNET, Cytoscape and ClueGO utilization. Copyright © 2017 Elsevier B.V. All rights

  8. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  9. Experimental infection with Brazilian Newcastle disease virus strain in pigeons and chickens

    Directory of Open Access Journals (Sweden)

    Adriano de Oliveira Torres Carrasco

    2016-03-01

    Full Text Available Abstract This study was designed with the goal of adding as much information as possible about the role of pigeons (Columba livia and chickens (Gallus gallus in Newcastle disease virus epidemiology. These species were submitted to direct experimental infection with Newcastle disease virus to evaluate interspecies transmission and virus-host relationships. The results obtained in four experimental models were analyzed by hemagglutination inhibition and reverse transcriptase polymerase chain reaction for detection of virus shedding. These techniques revealed that both avian species, when previously immunized with a low pathogenic Newcastle disease virus strain (LaSota, developed high antibody titers that significantly reduced virus shedding after infection with a highly pathogenic Newcastle disease virus strain (São Joao do Meriti and that, in chickens, prevent clinical signs. Infected pigeons shed the pathogenic strain, which was not detected in sentinel chickens or control birds. When the presence of Newcastle disease virus was analyzed in tissue samples by RT-PCR, in both species, the virus was most frequently found in the spleen. The vaccination regimen can prevent clinical disease in chickens and reduce viral shedding by chickens or pigeons. Biosecurity measures associated with vaccination programs are crucial to maintain a virulent Newcastle disease virus-free status in industrial poultry in Brazil.

  10. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  11. Features of mitral valve prolapse in young patients

    Directory of Open Access Journals (Sweden)

    M. A. Kuznetsova

    2015-06-01

    Full Text Available Due to the significant increase of complications in young patients with mitral valve prolapse detection of this disease is important. Aim. With the aim of studying the features of mitral valve prolapse 135 persons with mitral valve prolapse at the age of 18–25 years were examined. Methods and results. The features of mitral valve prolapsed were studied with echocardiography, electrocardiography, cardiointervalography. It was established that mitral valve prolapse (MVP in young age had different clinical picture. Patients with MVP 1 degree mainly had autonomic instability, and with 2 degree - mostly signs of connective tissue dysplasia. Conclusion. The presence of MVP is associated with abnormalities of the rhythm and conductivity: 1 degree - sinus tachycardia; the 2nd - sinus arrhythmia, signs of left ventricular hypertrophy and impaired repolarization of the myocardium.

  12. Aortic valve ochronosis: a rare manifestation of alkaptonuria.

    Science.gov (United States)

    Steger, Christina Maria

    2011-07-28

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.

  13. Comprehensive update on the new indications for transcatheter aortic valve replacement in the latest 2017 European guidelines for the management of valvular heart disease

    Science.gov (United States)

    Thonghong, Tasalak; De Backer, Ole; Søndergaard, Lars

    2018-01-01

    New European guidelines on the management of valvular heart disease—supported by the European Society of Cardiology (ESC) and European Association of CardioThoracic Surgery (EACTS)—were recently published. Although these guidelines are very comprehensive, these typically are not very inviting to read. In this document, we aimed to distil all the information about transcatheter aortic valve replacement (TAVR) in the new 2017 ESC/EACTS guidelines to the essential and give additional comments on the position of TAVR in 2017. PMID:29531767

  14. Clinical case of acute chord rupture of the mitral valve posterior leaflet in older patient with comorbidities

    OpenAIRE

    Zhuravlyova, L.; Lopina, N.; Kuznetsov, I.; Lopin, D.; Kramarenko, I.; Sumanova, I.

    2015-01-01

    The article describes the etiologic role of various factors such as chronic rheumatic heart disease, bacterial endocarditis, aortic valve stenosis, hypertension, coronary heart disease, including acute myocardial infarction, degenerative disease of the valves, connective tissue diseases, chest trauma, systemic lupus erythematosus, con-genital heart disease which leading to the mitral valve chords rupture, gives the current classification of the nosology and also features of manifestation and ...

  15. Surface Modification using Plasma treatments and Adhesion Peptide for Durable Tissue-Engineered Heart Valves

    International Nuclear Information System (INIS)

    Jung, Young mee; Kim, Soo Hyun

    2010-01-01

    Artificial heart valves are used in valvular heart diseases, but these valves have disadvantages that they cannot grow, repair and remodel. In current study, the strategies to development of in vitro cultured functional tissue by tissue engineering is available to heart valve disease. In the point of using viable autolougous cells, tissue engineered heart valves have some advantage to include that they can repair, remodel, and grow. Because heart valve is placed under the strong shear stress condition by pumping of heart, the durability of tissue-engineered heart valves is now questionable. The purpose of the study is to evaluate of the durability of tissue engineered heart valve with surface modified scaffolds under hemodynamic conditions

  16. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  17. A symmetric safety valve

    International Nuclear Information System (INIS)

    Burtraw, Dallas; Palmer, Karen; Kahn, Danny

    2010-01-01

    How to set policy in the presence of uncertainty has been central in debates over climate policy. Concern about costs has motivated the proposal for a cap-and-trade program for carbon dioxide, with a 'safety valve' that would mitigate against spikes in the cost of emission reductions by introducing additional emission allowances into the market when marginal costs rise above the specified allowance price level. We find two significant problems, both stemming from the asymmetry of an instrument that mitigates only against a price increase. One is that most important examples of price volatility in cap-and-trade programs have occurred not when prices spiked, but instead when allowance prices collapsed. Second, a single-sided safety valve may have unintended consequences for investment. We illustrate that a symmetric safety valve provides environmental and welfare improvements relative to the conventional one-sided approach.

  18. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    Science.gov (United States)

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  20. Lack of segregation of a Marfan-like phenotype associating marfanoie habitus and mitral valve disease with fibrillin gene on chromosome 15

    Energy Technology Data Exchange (ETDEWEB)

    VanMaldergen, L.; Hilbert, P.; Gillerot, Y. [Institut de Morphologie Pathologique, Loverval (Belgium)] [and others

    1994-09-01

    Apart from typical Marfan syndrome (MS), several Marfan-like conditions are known. One of those is the MASS syndrome (Mitral involvement, Aortic dilatation, Skin and Skeletal abnormalities) defined by Pyeritz et al. Among these, a dominantly inherited mitral valve prolapse with marfanoid habitus have also been reported. Until now, except for a Marfan-like condition described by Boileau et al., all Marfan families are linked to fib 15. A large Belgian pedigree with 25 affected patients among 62 at risk subjects spanning four generations is described. A syndrome including marfanoid skeletal dysplasia (tall stature, dolichostenomelia, arachnodactyly, pectus carinatum joint dislocation), prolapse and/or myxomatous degeneration of the mitral valve, but without aortic dilatation of eye involvement was observed. Although the phenotype fulfills Berlin diagnostic criteria for MS, it closely resembles MASS syndrome. Preliminary linkage results show discordance aggregation insertion in the fib 15 gene, as evaluated by intragenic microsatellite fib 15. Since Dietz et al. described a similar patient with fib 15 gene, we suggest that this variant of Marfan syndrome is genetically heterogeneous and caused by mutations, some of which are allelic to classical Marfan syndrome plus a subtype, some of which are not. Linkage studies are under way to further characterize the gene involved in the present family.

  1. Valve spindle gland

    International Nuclear Information System (INIS)

    Burda, Z.; Harazim, A.; Kerlin, K.

    1979-01-01

    A gland is proposed of the valve spindle designed for radioactive or otherwise harmful media, such as in nuclear power plant primary circuits. The gland is installed in the valve cover and consists of a primary and a secondary part and of a gland case partitioning the gland space into two chambers. The bottom face of the gland case is provided with a double-sided collar for controlling the elements of the bottom primary gland while the top face is provided with a removable flange. (M.S.)

  2. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  3. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  4. Actuation and Control of a Micro Electrohydraulic Digital Servo Valve

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Z Q; Hu, M J; Pei, X; Ruan, J [MOE Key Laboratory of Mechanical Manufacture and Automation Zhejiang University of Technology, 310014 (China)

    2006-10-15

    Structure of the micro digital servo valve is given. A micro stepper motor is used as electrical-to-mechanical interface of the valve. A special mechanical device is designed to convert the rotation of the stepper motor into the linear motion of the spool. This moving conversion device functions through an eccentric ball head rigidly connected to the axis of the stepper motor and plugged into a slot at the central spool land. While the stepper motor rotates, the eccentric ball head will actuate the spool to make a linear motion. Unlike conventional servo or proportional valves, in which the spool is forced to central position by a spring force, when the current supply is switched off, the digital valve has a program to control the spool to its central position each time the electrical power supply is switched on or off. The two end screws are used to adjust the position of the sleeve to sustain a mechanical central position coincided with electrical central position given by the stepper motor after initialization. The adjustment has to be carried once before the first time the servo valve is put into service. This paper presents theoretical analysis and experimental study of dynamic characteristics of the proposed micro digital servo valve. Experimental results demonstrated that the valve takes the advantage of high accuracy and fast response.

  5. Actuation and Control of a Micro Electrohydraulic Digital Servo Valve

    International Nuclear Information System (INIS)

    Yu, Z Q; Hu, M J; Pei, X; Ruan, J

    2006-01-01

    Structure of the micro digital servo valve is given. A micro stepper motor is used as electrical-to-mechanical interface of the valve. A special mechanical device is designed to convert the rotation of the stepper motor into the linear motion of the spool. This moving conversion device functions through an eccentric ball head rigidly connected to the axis of the stepper motor and plugged into a slot at the central spool land. While the stepper motor rotates, the eccentric ball head will actuate the spool to make a linear motion. Unlike conventional servo or proportional valves, in which the spool is forced to central position by a spring force, when the current supply is switched off, the digital valve has a program to control the spool to its central position each time the electrical power supply is switched on or off. The two end screws are used to adjust the position of the sleeve to sustain a mechanical central position coincided with electrical central position given by the stepper motor after initialization. The adjustment has to be carried once before the first time the servo valve is put into service. This paper presents theoretical analysis and experimental study of dynamic characteristics of the proposed micro digital servo valve. Experimental results demonstrated that the valve takes the advantage of high accuracy and fast response

  6. Experimental anti-GBM disease as a tool for studying spontaneous lupus nephritis.

    Science.gov (United States)

    Fu, Yuyang; Du, Yong; Mohan, Chandra

    2007-08-01

    Lupus nephritis is an immune-mediated disease, where antibodies and T cells both play pathogenic roles. Since spontaneous lupus nephritis in mouse models takes 6-12 months to manifest, there is an urgent need for a mouse model that can be used to delineate the pathogenic processes that lead to immune nephritis, over a quicker time frame. We propose that the experimental anti-glomerular basement membrane (GBM) disease model might be a suitable tool for uncovering some of the molecular steps underlying lupus nephritis. This article reviews the current evidence that supports the use of the experimental anti-GBM nephritis model for studying spontaneous lupus nephritis. Importantly, out of about 25 different molecules that have been specifically examined in the experimental anti-GBM model and also spontaneous lupus nephritis, all influence both diseases concordantly, suggesting that the experimental model might be a useful tool for unraveling the molecular basis of spontaneous lupus nephritis. This has important clinical implications, both from the perspective of genetic susceptibility as well as clinical therapeutics.

  7. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  8. Construction and characterization of valve for fast gas injection

    International Nuclear Information System (INIS)

    Ueda, M.; Rossi, J.O.; Aso, Y.; Mangueira, L.S.; Pereira, C.A.

    1989-01-01

    An electromagnetic valve for fast gas injection was built and characterized. This type of gas injection valve has been routinely applied to various plasma experiments: in magnetic confinement devices as TOKAMAK, RFP and Compact Toroids as well as intense ion beam and neutral particle generators. The valve is capable of injecting gas pulses with up to 80 m Torr peak pressure, rising time < 400 μs and duration time of 40 ms, in the present experimental set-up. It is easy to build and its components can be totally acquired in the country. (author)

  9. MEPR versus EEPR valves in open supermarket refrigerated display cabinets

    International Nuclear Information System (INIS)

    Tahir, A.; Bansal, P.K.

    2005-01-01

    This paper presents the comparative experimental field performance of mechanical evaporator pressure regulating valves (MEPR) and electronic evaporator pressure regulating valves (EEPR) under the identical operating conditions of supermarket open multi-deck refrigerated display cabinets. The main goal of the supermarket refrigeration system design is to keep the displayed product at the required constant temperature, while minimising the cooling load to increase the overall energy efficiency of the system. Field tests have shown that the electronic evaporator pressure valve has a significant effect on improving the cabinet temperature and reducing the rate of frost formation on the evaporator coils with subsequent improvements in the air curtain strength

  10. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  11. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  12. The association of incidentally detected heart valve calcification with future cardiovascular events

    OpenAIRE

    Gondrie, Martijn J. A.; van der Graaf, Yolanda; Jacobs, Peter C.; Oen, Ay L.; Mali, Willem P. Th. M.

    2010-01-01

    Objectives This study aims to investigate the prognostic value of incidental aortic valve calcification (AVC), mitral valve calcification (MVC) and mitral annular calcification (MAC) for cardiovascular events and non-rheumatic valve disease in particular on routine diagnostic chest CT. Methods The study followed a case-cohort design. 10410 patients undergoing chest CT were followed for a median period of 17 months. Patients referred for cardiovascular disease were excluded. A random sample of...

  13. Abordagem da valva do tronco pulmonar por desvio direito e uso de cânula bicaval: estudo experimental Approach of the pulmonary valve using right heart bypass and bicaval cannula: experimental study

    Directory of Open Access Journals (Sweden)

    Ana Maria RochaPinto e Silva

    2007-12-01

    Full Text Available OBJETIVO: O objetivo deste estudo foi reproduzir a cirurgia de abordagem da valva do tronco pulmonar por desvio direito, avaliando-se uma nova cânula venosa bicaval com balonetes insufláveis para uso por miniacesso. MÉTODOS: Utilizaram-se 15 suínos da raça Large-White, sendo cinco para a padronização técnica das vias de acesso e monitorização hemodinâmica, nove submetidos ao experimento por meio de esternotomia, e um animal excluído da amostra, operado por mínimo acesso ao tórax. O desvio direito foi estabelecido pela drenagem bicaval, sendo a cânula introduzida pela veia jugular interna direita e locada nas veias cavas cranial e caudal. Os parâmetros medidos foram: Pressão Arterial Média (PAM; Freqüência Cardíaca (FC; Saturação O2 (SAT O2; Capnografia (PetCO2 e Temperatura (T. A análise estatística foi feita comparando-se os valores antes e durante o desvio direito. RESULTADOS: No momento pré-desvio direito, obtiveramse os seguintes valores médios: PAM = 90,8 mmHg, FC = 101,6 bat/min, SAT O2 = 93,8%, PetCO2 = 28,4 mmHg, T = 36,1ºC. Durante o desvio direito, obtiveram-se os seguintes valores médios: PAM = 88,1 mmHg, FC = 98,0 bat/min, SAT O2 = 93,1%, PetCO2 = 25,3 mmHg e T = 36,9ºC. Comparandose as médias obtidas entre os dois momentos, verificou-se não haver diferenças significantes para a PAM, FC e SAT O2 e diferenças significantes para a PetCO2 e a T. CONCLUSÃO: A cânula bicaval com balonetes promoveu drenagem eficaz de ambas as veias cavas, permitindo a manutenção dos parâmetros hemodinâmicos durante o desvio direito, sendo possível realizar a abordagem da valva pulmonar.OBJECTIVE: To reproduce the surgery for correction of pulmonary valve anomalies using right heart bypass and a new bicaval cuffed venous cannula for minimal access surgery. METHODS: Fifteen Large-White pigs were used for this study. The standard technique model was established with the first five pigs, the experiment was done with

  14. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly r...

  15. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  16. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  17. Blocked Urethral Valves

    Science.gov (United States)

    ... if any damage has occurred to the upper urinary tract. Your pediatrician will consult with a pediatric nephrologist (kidney specialist) or nurologist, who may recommend surgery to remove the obstructing valves and prevent further infection or damage to the kidneys or urinary system. ...

  18. FEATURES OF CONTROLLING ELECTROPNEUMATIC VALVES OF ACTUATOR TO CONTROL ITS CLUTCH WITH ACCELERATION VALVE

    Directory of Open Access Journals (Sweden)

    O. A. Yaryta

    2018-01-01

    Full Text Available The article deals with one of the ways to control an actuator of the automated clutch control system. The aim is to design control of the electropneumatic actuator, to control its coupling with the acceleration valve on the basis of experimental research as well as to provide rational parameters of the automated clutch control system for the robotic transmission. The feature of the system is an acceleration valve in the design of the electropneumatic actuator to control the clutch. New links demand to adjust the way to control the actuator. The connection of Pulse-Width Modulation (PWM with single power supply pulses to control electropneumatic valves is substantiated. The quantitative characteristics of single control pulses and PWM ones are determined. The error of operation accuracy for various ways of the control of the electropneumatic actuator to control the clutch of the robotic transmission is determined. Obtained separate PWM area is designed to suppress the initial hysteresis when the rod of the clutch actuator is moved. An algorithm for the operation of a clutch control system is proposed, taking into account the use of two modes of operation of solenoid valves. A graphical interpretation of the clutch control algorithm is presented, which gives an idea of the location of the constant signal feeding zones to the solenoid valve, as well as the operation areas of the solenoid valve in PWM mode. The control algorithm of the clutch booster provides a mode of guaranteed absence of excess pressure in the pneumatic cylinder after releasing the clutch pedal, provided that two normally closed solenoid valves are used. This configuration of the electro-pneumatic clutch control system allows the use of an emergency clutch release system in case of voltage absence. The reference algorithm for filtering the array of data coming from the feedback sensor, as well as the numerical values of the delay caused by the presence of a filter, are given.

  19. Reconstituição da valva pulmonar e via de saída do ventrículo direito, com prótese bivalvular e prótese tubular valvada de tronco pulmonar de porco: estudo experimental e aplicação clínica Pulmonary valve and right ventricular oulet tract reconstruction with biovalvular prostheses and valved tubular prostheses of the pig pulmonary artery: experimental study and clinical application

    Directory of Open Access Journals (Sweden)

    Miguel A Maluf

    1993-03-01

    aplicação clínica da prótese bivalvular foi realizada em 3 pacientes portadores de t. de Fallot associada a hipoplasía do anel pulmonar (2 casos e agenesia da valva pulmonar (1 caso, com idades de 16, 2 e 7 anos. Após evolução de 3 a 10 meses, os gradientes variaram entre 10 mmHg e 20 mmHg e discreta insuficiência pulmonar valvar ao estudo ecodopplercardiográfico. A prótese tubular valvar foi implantada em 2 pacientes portadores de atresia pulmonar associada a comunicação interventricular (CIV e outro a transposição corrigida das grandes artérias (TCGA associada a GIV e estenose subpulmonar, com idades de 10 e 6 anos, respectivamente. Após evolução de 5 a 12 meses, foram detectados suficiência da valva pulmonar, gradientes entre 15 mmHg e 18 mmHg, sem sinais de calcificação. Apesar de se considerar aceitáveis os resultados desta experiência, a ampliação das indicações deverá ser feita com cautela, até o melhor conhecimento da resistência da prótese a calcificação, infecção, obstrução e rotura.Obstruction of the right ventricle outlet tract (RVOT has been the object of arguments regarding its surgical correction, while there are different criteria for reconstruction. Thus two kinds of prostheses were developed from the pig pulmonary trunk (PT. 1 One with two valves of the pulmonary valve (PV, named bivalvular graft, and could be used for correction of Fallot with pulmonary ring hypoplasia. 2 The other, with a tubular form, containing the pig PV itself and named valved conduit, could be used in RVOT reconstruction for patients with pulmonary atresia (PA. These prostheses were tested in an experimental model: implant of the bivalvular graft was performed in 16 sheep with the aid of extracorporeal circulation (ECC. The surgical technique consisted of resection of the two valves of the PV and of the anterior wall of the infundibulum; this condition was similar to Fallot correction. Implant of the valvular conduit was carried out in 12

  20. Management of Ocular Diseases Using Lutein and Zeaxanthin: What Have We Learned from Experimental Animal Studies?

    Directory of Open Access Journals (Sweden)

    Chunyan Xue

    2015-01-01

    Full Text Available Zeaxanthin and lutein are two carotenoid pigments that concentrated in the retina, especially in the macula. The effects of lutein and zeaxanthin on the prevention and treatment of various eye diseases, including age-related macular degeneration, diabetic retinopathy and cataract, ischemic/hypoxia induced retinopathy, light damage of the retina, retinitis pigmentosa, retinal detachment, and uveitis, have been studied in different experimental animal models. In these animal models, lutein and zeaxanthin have been reported to have beneficial effects in protecting ocular tissues and cells (especially the retinal neurons against damage caused by different etiological factors. The mechanisms responsible for these effects of lutein and zeaxanthin include prevention of phototoxic damage by absorption of blue light, reduction of oxidative stress through antioxidant activity and free radical scavenging, and their anti-inflammatory and antiangiogenic properties. The results of these experimental animal studies may provide new preventive and therapeutic procedures for clinical management of various vision-threatening diseases.

  1. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Plastik på trikuspidalklappen (Tricuspid valve annuloplasty. The neglected valve)

    DEFF Research Database (Denmark)

    Pedersen, Thais A L; Wierup, Per; Pedersen, Lia Mendes

    2010-01-01

    INTRODUCTION: Tricuspid valve regurgitation (TVR) is often secondary to left-sided or congenital heart disease (CHD). Surgical correction of TVR is indicated when the primary abnormalities require operation. MATERIAL AND METHODS: Retrospective analysis of all 50 patients (mean age: 65 years (rang...

  3. Tricuspid valve endocarditis

    Science.gov (United States)

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  4. Circadian rhythms and metabolic syndrome: from experimental genetics to human disease

    OpenAIRE

    Maury, Eleonore; Ramsey, Kathryn Moynihan; Bass, Joseph

    2010-01-01

    The incidence of the metabolic syndrome represents a spectrum of disorders that continue to increase across the industrialized world. Both genetic and environmental factors contribute to metabolic syndrome and recent evidence has emerged to suggest that alterations in circadian systems and sleep participate in the pathogenesis of the disease. In this review, we highlight studies at the intersection of clinical medicine and experimental genetics that pinpoint how perturbations of the internal ...

  5. Reversal of experimental colitis disease activity in mice following administration of an adenoviral IL-10 vector

    OpenAIRE

    Sasaki, Makoto; Mathis, J Michael; Jennings, Merilyn H; Jordan, Paul; Wang, Yuping; Ando, Tomoaki; Joh, Takashi; Alexander, J Steven

    2005-01-01

    Abstract Genetic deficiency in the expression of interleukin-10 (IL-10) is associated with the onset and progression of experimental inflammatory bowel disease (IBD). The clinical significance of IL-10 expression is supported by studies showing that immune-augmentation of IL-10 prevents inflammation and mucosal damage in animal models of colitis and in human colitis. Interleukin-10 (IL-10), an endogenous anti-inflammatory and immunomodulating cytokine, has been shown to prevent some inflammat...

  6. Studies on the effects of ionizing radiation on the normal and diseased liver in experimental animals

    International Nuclear Information System (INIS)

    Mahmoud, S.A.

    1981-01-01

    The experiments carried out in the present study primarily concerned with the effects of ionizing radiations on the normal and diseased liver in experimental animals (mice). Different radiation intensities and different exposure schemes were used to irradiate both healthy and schistosoma mansoni infected animals. A group of uninfected and unirradiated animals were used as controls. Follow up studies were performed every 6 weeks for 30 weeks. These included histopathological studies of the liver damage at every observation periods for all animal groups

  7. Graphene spin valve: An angle sensor

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Zahir, E-mail: zahir.upc@gmail.com [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Hussain, Ghulam [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Siddique, Salma [Department of Bioscience & Biotechnology, Sejong University, Seoul 143-747 (Korea, Republic of); Iqbal, Muhammad Waqas [Department of Physics, Riphah Institute of Computing and Applied Sciences (RICAS), Riphah International University, Lahore (Pakistan)

    2017-06-15

    Graphene spin valves can be optimized for various spintronic applications by tuning the associated experimental parameters. In this work, we report the angle dependent magnetoresistance (MR) in graphene spin valve for different orientations of applied magnetic field (B). The switching points of spin valve signals show a clear shift towards higher B for each increasing angle of the applied field, thus sensing the response for respective orientation of the magnetic field. The angular variation of B shifts the switching points from ±95 G to ±925 G as the angle is varied from 0° to 90° at 300 K. The observed shifts in switching points become more pronounced (±165 G to ±1450 G) at 4.2 K for similar orientation. A monotonic increase in MR ratio is observed as the angle of magnetic field is varied in the vertical direction at 300 K and 4.2 K temperatures. This variation of B (from 0° to 90°) increases the magnitude of MR ratio from ∼0.08% to ∼0.14% at 300 K, while at 4.2 K it progresses to ∼0.39% from ∼0.14%. The sensitivity related to angular variation of such spin valve structure can be employed for angle sensing applications.

  8. Echocardiographic pattern and severity of valve dysfunction in ...

    African Journals Online (AJOL)

    Background: Rheumatic heart disease (RHD) is the commonest acquired heart disease in children worldwide but in Uganda, data is scarce regarding its morbidity and mortality. The disease has a progressive course and patients usually require valve repair/replacement in the future. Objectives:To describe the frequency of ...

  9. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar; Desenvolvimento de um sistema de monitoracao e diagnostico utilizando logica Fuzzy aplicado a valvulas de controle de processo do CEA - Centro Experimental Aramar

    Energy Technology Data Exchange (ETDEWEB)

    Porto Junior, Almir Carlos Soares

    2014-07-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009{sup th} by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  10. The dilemma of complicated shunt valves: How to identify patients with posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage who will benefit from a simple valve?

    Directory of Open Access Journals (Sweden)

    Christian von der Brelie

    2016-01-01

    Full Text Available Background: Sophisticated shunt valves provide the possibility of pressure adjustment and antisiphon control but have a higher probability of valve dysfunction especially in a posthemorrhagic setting. The aim of the present study is to analyze the clinical outcome of patients with shunt dependent posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage (SAH in order to identify patients who would benefit from a simple differential pressure valve. Methods: From 2000 to 2013, 547 patients with aneurysmatic SAH were treated at our institution, 114 underwent ventricular shunt placement (21.1%. 47 patients with available pre- and post-operative computed tomography scans, and an available follow-up of minimum 6 months were included. In order to measure the survival time which a nonprogrammable differential pressure valve would have had in an individual patient we defined the initial equalized shunt survival time (IESS. IESS is the time until surgical revisions of fixed differential pressure or flow-regulated valves for the treatment of over- or under-drainage as well as re-programming of adjustable valves due to over- or under-drainage. Results: Twenty patients were treated with fixed differential pressure valves, 15 patients were treated with flow-regulated valves, and 12 underwent ventriculoperitoneal (VP shunt placement with differential pressure valves assisted by a gravitational unit. Patients who reacted with remarkable changes of the ventricular width after the insertion of external ventricular drainage (EVD, before shunt placement, showed a significantly longer IESS. Conclusions: Decline of the ventricular width after EVD placement was a predictor for successful VP shunt therapy in the later course of disease. Possibly, this could allow identifying patients who benefit from a simple differential pressure valve or a flow-regulated valve, and thus could possibly avoid valve-associated complications of a programmable valve in the

  11. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    Science.gov (United States)

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. © 2014 Blackwell Verlag GmbH.

  12. Exercise-based cardiac rehabilitation after heart valve surgery

    DEFF Research Database (Denmark)

    Hansen, T B; Zwisler, Ann-Dorthe; Berg, S K

    2015-01-01

    BACKGROUND: Owing to a lack of evidence, patients undergoing heart valve surgery have been offered exercise-based cardiac rehabilitation (CR) since 2009 based on recommendations for patients with ischaemic heart disease in Denmark. The aim of this study was to investigate the impact of CR...... expensive outpatient visits. Further studies should investigate the benefits of CR to heart valve surgery patients as part of a formal cost-utility analysis....

  13. Defect in mitochondrial functions in damaged human mitral valve

    OpenAIRE

    Shinde, Santosh; Kumar, Pawan; Mishra, Kaushala; Patil, Neela

    2006-01-01

    Mitochondrial diseases are a heterogeneous group of disorders in which a primary mitochondrial dysfunction is proven by morphological, biochemical, and genetic examinations. The mitral valve has important function in the regulation of blood flow from one chamber to another. Often, the mitral valve becomes abnormal with age, in Rheumatic fever or it is abnormal from birth (Congenital) or it can be destroyed by infection i.e. bacterial endocarditis and needs replacement. Myocardial function dep...

  14. Circadian rhythms and metabolic syndrome: from experimental genetics to human disease.

    Science.gov (United States)

    Maury, Eleonore; Ramsey, Kathryn Moynihan; Bass, Joseph

    2010-02-19

    The incidence of the metabolic syndrome represents a spectrum of disorders that continue to increase across the industrialized world. Both genetic and environmental factors contribute to metabolic syndrome and recent evidence has emerged to suggest that alterations in circadian systems and sleep participate in the pathogenesis of the disease. In this review, we highlight studies at the intersection of clinical medicine and experimental genetics that pinpoint how perturbations of the internal clock system, and sleep, constitute risk factors for disorders including obesity, diabetes mellitus, cardiovascular disease, thrombosis and even inflammation. An exciting aspect of the field has been the integration of behavioral and physiological approaches, and the emerging insight into both neural and peripheral tissues in disease pathogenesis. Consideration of the cell and molecular links between disorders of circadian rhythms and sleep with metabolic syndrome has begun to open new opportunities for mechanism-based therapeutics.

  15. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    Science.gov (United States)

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Formation of catalyst deposits in flue gas slide valves at an FCC unit: an experimental solution; Formacao de depositos de catalisador em valvula corredica dos gases de combustao de unidade de FCC: uma experiencia de solucao

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luiz Eduardo Magalhaes Correa da; Rodrigues, Jayme Thadeu [PETROBRAS (Brazil). Refinaria Alberto Pasqualini

    1990-04-01

    We describe flue gas slide valve sticking at the FCC (fluid catalytic cracking) Unit Alberto Pasqualini Refinery (REFAP/PETROBRAS). Findings show that this sticking was due to the formation of catalyst deposits below the slide valve guides. A retrospective survey has suggested that what caused troubleshooting was dragging by medium steam in the cat cracker. We present a theoretical formulation to account for catalyst deposit formation, as well as some points that should be observed in order to minimize the problem. (author) 13 refs., 8 figs., 2 tabs.

  17. Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    NARCIS (Netherlands)

    Willemink, Martin J.; Takx, Richard A. P.; Isgum, I; de Koning, Harry J.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; Budde, Ricardo P. J.; Leiner, Tim; Vliegenthart, Rozemarijn; de Jong, Pim A.

    To assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced low-radiation-dose

  18. Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    NARCIS (Netherlands)

    M.J. Willemink (Martin J.); R.A.P. Takx (Richard A.); I. Isgum (Ivana); H.J. de Koning (Harry); M. Oudkerk (Matthijs); W.P. Mali (Willem); R.P.J. Budde (Ricardo); I. Leiner (Tim); R. Vliegenthart (Rozemarijn); P.A. de Jong (Pim)

    2015-01-01

    textabstractTo assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced

  19. Moderate exercise does not increase the severity of mitral regurgitation due to mitral valve prolapse

    DEFF Research Database (Denmark)

    Pecini, Redi; Dalsgaard, Morten; Møller, Daniel Vega

    2010-01-01

    Mitral regurgitation (MR) secondary to ischemic heart disease (IHD) increases during exercise. We tested the hypothesis that the same is also true for MR due to mitral valve prolapse (MVP).......Mitral regurgitation (MR) secondary to ischemic heart disease (IHD) increases during exercise. We tested the hypothesis that the same is also true for MR due to mitral valve prolapse (MVP)....

  20. A Typical Immune T/B Subset Profile Characterizes Bicuspid Aortic Valve: In an Old Status?

    Directory of Open Access Journals (Sweden)

    Carmela R. Balistreri

    2018-01-01

    Full Text Available Bicuspid valve disease is associated with the development of thoracic aortic aneurysm. The molecular mechanisms underlying this association still need to be clarified. Here, we evaluated the circulating levels of T and B lymphocyte subsets associated with the development of vascular diseases in patients with bicuspid aortic valve or tricuspid aortic valve with and without thoracic aortic aneurysm. We unveiled that the circulating levels of the MAIT, CD4+IL−17A+, and NKT T cell subsets were significantly reduced in bicuspid valve disease cases, when compared to tricuspid aortic valve cases in either the presence or the absence of thoracic aortic aneurysm. Among patients with tricuspid aortic valve, these cells were higher in those also affected by thoracic aortic aneurysm. Similar data were obtained by examining CD19+ B cells, naïve B cells (IgD+CD27−, memory unswitched B cells (IgD+CD27+, memory switched B cells (IgD−CD27+, and double-negative B cells (DN (IgD−CD27−. These cells resulted to be lower in subjects with bicuspid valve disease with respect to patients with tricuspid aortic valve. In whole, our data indicate that patients with bicuspid valve disease show a quantitative reduction of T and B lymphocyte cell subsets. Future studies are encouraged to understand the molecular mechanisms underlying this observation and its pathophysiological significance.

  1. Improvement of a Pneumatic Control Valve with Self-Holding Function

    Science.gov (United States)

    Dohta, Shujiro; Akagi, Tetsuya; Kobayashi, Wataru; Shimooka, So; Masago, Yusuke

    2017-10-01

    The purpose of this study is to develop a small-sized, lightweight and low-cost control valve with low energy consumption and to apply it to the assistive system. We have developed some control valves; a tiny on/off valve using a vibration motor, and an on/off valve with self-holding function. We have also proposed and tested the digital servo valve with self-holding function using permanent magnets and a small-sized servo motor. In this paper, in order to improve the valve, an analytical model of the digital servo valve is proposed. And the simulated results by using the analytical model and identified parameters were compared with the experimental results. Then, the improved digital servo valve was designed based on the calculated results and tested. As a result, we realized the digital servo valve that can control the flow rate more precisely while maintaining its volume and weight compared with the previous valve. As an application of the improved valve, a position control system of rubber artificial muscle was built and the position control was performed successfully.

  2. Development of a butterfly check valve model under natural circulation conditions

    International Nuclear Information System (INIS)

    Rao, Yuxian; Yu, Lei; Fu, Shengwei; Zhang, Fan

    2015-01-01

    Highlights: • Bases on Lim’s swing check valve model, a butterfly check valve model was developed. • The method to quantify the friction torque T F in Li’s model was corrected. • The developed model was implemented into the RELAP5 code and verified. - Abstract: A butterfly check valve is widely used to prevent a reverse flow in the pipe lines of a marine nuclear power plant. Under some conditions, the natural circulation conditions in particular, the fluid velocity through the butterfly check valve might become too low to hold the valve disk fully open, thereby the flow resistance of the butterfly check valve varies with the location of the valve disk and as a result the fluid flow is significantly affected by the dynamic motion of the valve disk. Simulation of a pipe line that includes some butterfly check valves, especially under natural circulation conditions, is thus complicated. This paper focuses on the development of a butterfly check valve model to enhance the capability of the thermal–hydraulic system code and the developed model is implemented into the RELAP5 code. Both steady-state calculations and transient calculations were carried out for the primary loop system of a marine nuclear power plant and the calculation results are compared with the experimental data for verification purpose. The simulation results show an agreement with the experimental data

  3. Aortic valve-sparing surgery in Marfan syndrome.

    Science.gov (United States)

    Nachum, Eyal; Shinfeld, Amichay; Kogan, Alexander; Preisman, Sergey; Levin, Shany; Raanani, Ehud

    2013-08-01

    Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain. Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 +/- 13 vs. 53 +/- 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients. While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (reaching 8 years with a mean of 34 +/- 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients. Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

  4. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    Science.gov (United States)

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Calcific aortic valve damage as a risk factor for cardiovascular events

    International Nuclear Information System (INIS)

    Wasilewski, Jarosław; Mirota, Kryspin; Wilczek, Krzysztof; Głowacki, Jan; Poloński, Lech

    2012-01-01

    Aortic valve calcification (AVC) is a common disease of the elderly. It is a progressive disease ranging from mild valve thickening to severe calcification with aortic valve stenosis. Risk factors for AVC are similar to those for atherosclerosis: age, gender, hypercholesterolemia, diabetes, hypertension, smoking and renal failure. AVC shares many similarities to atherosclerosis, including inflammatory cells and calcium deposits, and correlates with coronary plaque burden. Presence of AVC is associated with increased risk of adverse cardiovascular events. The objective for this review is to discuss the clinical features, natural history and prognostic significance of aortic valve calcifications, including mechanical and hemodynamic factors of flow distribution

  6. In-operation inspection technology development-4 ''development of degradation prediction technology for motor-operated valves''

    International Nuclear Information System (INIS)

    Kikuo, Takeshima; Yuichi, Higashikawa; Masahiro, Koike; Kenji, Matsumoto; Eiji, O'shima

    2001-01-01

    A method for degradation predicting technology has been proposed for motor operated valves in nuclear power plants which is based on the concept of condition monitoring for maintenance. This method (degradation prediction technology) eliminates the unnecessary overhaul of valves and realizes high reliability and economy. The degradation mechanism was clarified by long time heating experiments of gasket and gland packing and the wear test for them and stem nut to research valve parts degradation by stress (pressure, temperature, etc) during plant operation. Effective electric power measurements for motor operated valves were confirmed to be useful discovering valve part failures. The motor operated valve degradation prediction system was developed on the basis of the experiment results and mechanism. The system is able to predict the degradation of valve parts (gasket/gland packing, stem, stem nut, etc) utilizing plant data (pressure, temperature, etc) and effective power of the motor. The life of valve parts can be estimated from the experimental results. (authors)

  7. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  8. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  9. Estudo experimental do implante transcateter de prótese valvada autoexpansível na via de saída do ventrículo direito em porcos Transcatheter implantation of self-expandable valved prosthesis in outlet right ventricle an experimental study in pigs

    Directory of Open Access Journals (Sweden)

    José Cícero Stocco Guilhen

    2011-09-01

    Full Text Available INTRODUÇÃO: Nos pacientes portadores de cardiopatias congênitas que foram submetidos à valvotomia pulmonar ou cirurgias de ampliação com o uso do anel da válvula pulmonar, a insuficiência ou estenose pulmonar residual pode acarretar falência cardíaca direita com deterioração clínica. Essas crianças necessitam de múltiplas intervenções ao longo de suas vidas, que impõem uma elevada taxa de morbidade e mortalidade. OBJETIVO: Desenvolvimento de uma técnica menos invasiva para implante de uma prótese valvada através do ventrículo direito. MÉTODOS: A prótese valvada consiste em um anel metálico construído com nitinol autoexpansível, revestida de poliéster, onde três cúspides de pericárdio bovino foram montadas. Doze porcos foram utilizados para a realização dos implantes. Foi realizado controle ecocardiográfico imediatamente após o implante e com uma, quatro, oito e 12 semanas. RESULTADOS: Um animal apresentou refluxo de grau moderado a importante e outros três refluxo de grau leve. Os gradientes transvalvares medidos antes do implante variavam entre 3 a 6 mmHg, sendo que, logo após o implante, houve aumento dos gradientes que variaram de 7 a 45 mmHg. Houve queda desses gradientes, sendo que em apenas quatro dos 12 animais os gradientes estavam acima de 20 mmHg. Em seis animais, ocorreu a formação de trombo na prótese, sendo esta a complicação mais frequente. CONCLUSÃO: Esses achados evidenciam a necessidade da realização de estudos com a utilização de anticoagulantes e ou antiagregantes plaquetários na tentativa de diminuir esse evento. O estudo pretende apresentar subsídios para o início do emprego de próteses valvares que poderiam ser implantadas através de técnicas menos invasivasINTRODUCTION: Patients with congenital heart disease who underwent pulmonary valvotomy or surgery to open the pulmonary valve ring are prone to develop residual pulmonary insufficiency or stenosis that may lead to

  10. Charging valve of the full hydraulic braking system

    Directory of Open Access Journals (Sweden)

    Jinshi Chen

    2016-03-01

    Full Text Available It is known that the full hydraulic braking system has excellent braking performance. As the key component of the full hydraulic braking system, the parameters of the accumulator charging valve have a significant effect on the braking performance. In this article, the key parameters of the charging valve are analyzed through the static theoretical and an Advanced Modeling Environment for performing Simulation of engineering systems (AMESim simulation model of the dual-circuit accumulator charging valve is established based on the real structure parameters first. Second, according to the results of the dynamic simulation, the dynamic characteristics of the charging pressure, the flow rate, and the frequency of the charging valve are studied. The key parameters affecting the serial production are proposed and some technical advices for improving the performance of the full hydraulic system are provided. Finally, the theoretical analysis is validated by the simulation results. The comparison between the simulation results and the experimental results indicates that the simulated AMESim model of the charging valve is accurate and credible with the error rate inside 0.5% compared with the experimental result. Hence, the performance of the charging valve meets the request of the full hydraulic braking system exactly.

  11. Controlling the cavitation phenomenon of evolution on a butterfly valve

    International Nuclear Information System (INIS)

    Baran, G; Safta, C A; Catana, I; Magheti, I; Savu, M

    2010-01-01

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  12. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Baran, G; Safta, C A [Department of Hydraulic and Hydraulic Machineries, University Politehnica of Bucharest, 313 Splaiul Independentei, Bucharest, 060042 (Romania); Catana, I [Department of Control and Computer Science, University Politehnica of Bucharest (Romania); Magheti, I; Savu, M, E-mail: baran_gheorghe@yahoo.co.u [Department of Mechanical Engineering, University Politehnica of Bucharest (Romania)

    2010-08-15

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  13. Aortic valve calcification and mild tricuspid regurgitation but no clinical heart disease after 8 years of dopamine agonist therapy for prolactinoma

    NARCIS (Netherlands)

    Kars, Marleen; Delgado, Victoria; Holman, Eduard R.; Feelders, Richard A.; Smit, Johannes W. A.; Romijn, Johannes A.; Bax, Jeroen J.; Pereira, Alberto M.

    2008-01-01

    Treatment with ergot-derived dopamine agonists, pergolide, and cabergoline has been associated with an increased frequency of valvular heart disease in Parkinson's disease. The aim of the present study was to assess the prevalence of valvular heart disease in patients treated with dopamine agonists

  14. Aortic valve calcification and mild tricuspid regurgitation but no clinical heart disease after 8 years of dopamine agonist therapy for prolactinoma

    NARCIS (Netherlands)

    M. Kars; V. Delgado (Victoria); E.R. Holman (Eduard); R.A. Feelders (Richard); J.W.A. Smit (Jan); J.A. Romijn (Johannes); J.J. Bax (Jeroen); A.M. Pereira (Alberto)

    2008-01-01

    textabstractObjective: Treatment with ergot-derived dopamine agonists, pergolide, and cabergoline has been associated with an increased frequency of valvular heart disease in Parkinson's disease. The aim of the present study was to assess the prevalence of valvular heart disease in patients treated

  15. Prevaccination with SRL172 (heat-killed Mycobacterium vaccae) inhibits experimental periodontal disease in Wistar rats

    Science.gov (United States)

    Breivik, T; Rook, G A W

    2000-01-01

    Periodontal disease is a bacterial dental plaque-induced destructive inflammatory condition of the tooth-supporting tissues, which is thought to be mediated by T lymphocytes secreting T helper 2 (Th2) cytokines, resulting in recruitment of high numbers of antibody-producing B lymphocytes/plasma cells as well as polymorphonuclear leucocytes (PMN) secreting tissue-destructive components, such at matrix metalloproteinases and reactive oxygen metabolites into the gingival connective tissues. One treatment strategy may be to down-regulate the Th2 response to those dental plaque microorganisms which induce the destructive inflammatory response. In this study we have examined the effects of a potent down-regulator of Th2 responses on ligature-induced periodontal disease in an experimental rat model. A single s.c. injection into Wistar rats of 0·1 or 1 mg of SRL172, a preparation of heat-killed Mycobacterium vaccae (NCTC 11659), 13 days before application of the ligature, significantly reduced the subsequent destruction of the tooth-supporting tissues, as measured by loss of periodontal attachment fibres (P < 0·001) and bone (P < 0·002). This protective effect occurred not only on the experimental (ligatured) side but also on the control unligatured side. SRL172 has undergone extensive toxicological studies and safety assessments in humans, and it is suggested that it may provide a safe and novel therapeutic approach to periodontal disease. PMID:10844524

  16. A design strategy for magnetorheological dampers using porous valves

    International Nuclear Information System (INIS)

    Hu, W; Robinson, R; Wereley, N M

    2009-01-01

    To design a porous-valve-based magnetorheological (MR) damper, essential design parameters are presented. The key elements affecting the damper performance are identified using flow analysis in porous media and an empirical magnetic field distribution in the porous valve. Based on a known MR fluid, the relationship between the controllable force of the damper and the porous valve characteristics, i.e. porosity and tortuosity, is developed. The effect of the porosity and tortuosity on the field-off damping force is exploited by using semi-empirical flow analysis. The critical flow rate for the onset of nonlinear viscous damping force is determined. Using the above design elements, an MR damper using by-pass porous valve is designed and tested. The experimental damper force and equivalent damping are compared with the predicted results to validate this design strategy.

  17. A design strategy for magnetorheological dampers using porous valves

    Energy Technology Data Exchange (ETDEWEB)

    Hu, W; Robinson, R; Wereley, N M [Smart Structures Laboratory, Alfred Gessow Rotorcraft Center, Department of Aerospace Engineering, University of Maryland, College Park, MD 20742 (United States)], E-mail: wereley@umd.edu

    2009-02-01

    To design a porous-valve-based magnetorheological (MR) damper, essential design parameters are presented. The key elements affecting the damper performance are identified using flow analysis in porous media and an empirical magnetic field distribution in the porous valve. Based on a known MR fluid, the relationship between the controllable force of the damper and the porous valve characteristics, i.e. porosity and tortuosity, is developed. The effect of the porosity and tortuosity on the field-off damping force is exploited by using semi-empirical flow analysis. The critical flow rate for the onset of nonlinear viscous damping force is determined. Using the above design elements, an MR damper using by-pass porous valve is designed and tested. The experimental damper force and equivalent damping are compared with the predicted results to validate this design strategy.

  18. Fast valve for the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Oversluizen, T.

    1981-01-01

    A prototype fast closing, all metal, UHV-compatible valve has been built to protect the NSLS storage rings from sudden vacuum failures which may occur in the experimental beamlines. When triggered, an area of 10 x 140 mm is covered by a spring-driven, guillotine type blade, which forms a high impedance to the inrushing gas. This fast closure assures the protection of the ring vacuum from contamination before the slower UHV valve can be sealed off. Closing times on the order of 3 to 5 msec have been measured. The valve is triggered by a commercial solenoid, powered by a 16,800 μF capacitor bank at 100 volts. Because the valve is situated in a high radiation area, it is remotely resettable

  19. Pressure control valve using proportional electro-magnetic solenoid actuator

    International Nuclear Information System (INIS)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won

    2006-01-01

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed

  20. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  1. [Management of chronic kidney disease guided by the theory of Traditional Chinese Medicine: an experimental study].

    Science.gov (United States)

    Wen, Ji; Xie, Xi-Sheng; Zhang, Ming-Hua; Mao, Nan; Zhang, Cheng-Long; Xie, Lin-Shen; Cheng, Yuan; Zhang, Zi-Yuan; Fan, Jun-Ming

    2014-01-01

    To determine the impact of Traditional Chinese Medicine on patients with chronic kidney disease (CKD). A total of 225 CKD patients in an outpatient department were recruited for this study, among whom 170 received regular Western and Chinese medicine treatments (control group) and 55 received treatments guided by the theory of Traditional Chinese Medicine (experimental group). The effectiveness of the treatments was determined through a pre-post comparison. Significant pre-intervention differences in age (P control group. No significant differences between the groups were found in changes of uric acid (P = 0.475), urine protein (P = 0.058), urine red cells (P = 0.577), and urine white cells (P = 0.01). A greater level of increase in estimated glomerular filtration rate was found in the experimental group compared with the control (P theory of Traditional Chinese Medicine can improve renal function through influencing glomerular filtration rate. The effect is more prominent than the regular treatment regime.

  2. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  3. Neurotrophin 3 upregulates proliferation and collagen production in human aortic valve interstitial cells: a potential role in aortic valve sclerosis.

    Science.gov (United States)

    Yao, Qingzhou; Song, Rui; Ao, Lihua; Cleveland, Joseph C; Fullerton, David A; Meng, Xianzhong

    2017-06-01

    Calcific aortic valve disease (CAVD) is a leading cardiovascular disorder in the elderly. Diseased aortic valves are characterized by sclerosis (fibrosis) and nodular calcification. Sclerosis, an early pathological change, is caused by aortic valve interstitial cell (AVIC) proliferation and overproduction of extracellular matrix (ECM) proteins. However, the mechanism of aortic valve sclerosis remains unclear. Recently, we observed that diseased human aortic valves overexpress growth factor neurotrophin 3 (NT3). In the present study, we tested the hypothesis that NT3 is a profibrogenic factor to human AVICs. AVICs isolated from normal human aortic valves were cultured in M199 growth medium and treated with recombinant human NT3 (0.10 µg/ml). An exposure to NT3 induced AVIC proliferation, upregulated the production of collagen and matrix metalloproteinase (MMP), and augmented collagen deposition. These changes were abolished by inhibition of the Trk receptors. NT3 induced Akt phosphorylation and increased cyclin D1 protein levels in a Trk receptor-dependent fashion. Inhibition of Akt abrogated the effect of NT3 on cyclin D1 production. Furthermore, inhibition of either Akt or cyclin D1 suppressed NT3-induced cellular proliferation and MMP-9 and collagen production, as well as collagen deposition. Thus, NT3 upregulates cellular proliferation, ECM protein production, and collagen deposition in human AVICs. It exerts these effects through the Trk-Akt-cyclin D1 cascade. NT3 is a profibrogenic mediator in human aortic valve, and overproduction of NT3 by aortic valve tissue may contribute to the mechanism of valvular sclerosis. Copyright © 2017 the American Physiological Society.

  4. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    Science.gov (United States)

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  5. Management of deer for experimental studies with foor-and-mouth disease virus.

    Science.gov (United States)

    Gibbs, E P; McDiarmid, A; Rowe, J J

    1975-06-07

    Red, sika, fallow, roe and muntjac deer adapted to captivity in experimental units designed for working with foot-and-mouth disease. The red, sika and fallow deer readily accepted rolled oats and hay as their staple diet. This diet was replaced for the roe and muntjac deer with flaked maize, calf starter pellets and green browse. Etorphine/acepromazine ans xylazine were found to be suitable sedatives for detailed examination of the tongue and oral cavity of the various species of deer and gave adequate analgesia for the inoculation and collection of virus samples.

  6. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  7. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  8. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  9. Protective effects of panax notoginseng saponins on cardiovascular diseases: a comprehensive overview of experimental studies.

    Science.gov (United States)

    Yang, Xiaochen; Xiong, Xingjiang; Wang, Heran; Wang, Jie

    2014-01-01

    Panax notoginseng saponins (PNS) are one of the most important compounds derived from roots of the herb Panax notoginseng which are traditionally used as a hemostatic medicine to control internal and external bleeding in China for thousands of years. To date, at least twenty saponins were identified and some of them including notoginsenoside R1, ginsenoside Rb1, and ginsenoside Rg1 were researched frequently in the area of cardiovascular protection. However, the protective effects of PNS on cardiovascular diseases based on experimental studies and its underlying mechanisms have not been reviewed systematically. This paper reviewed the pharmacology of PNS and its monomers Rb1, Rg1, and R1 in the treatment for cardiovascular diseases.

  10. Protective Effects of Panax Notoginseng Saponins on Cardiovascular Diseases: A Comprehensive Overview of Experimental Studies

    Directory of Open Access Journals (Sweden)

    Xiaochen Yang

    2014-01-01

    Full Text Available Panax notoginseng saponins (PNS are one of the most important compounds derived from roots of the herb Panax notoginseng which are traditionally used as a hemostatic medicine to control internal and external bleeding in China for thousands of years. To date, at least twenty saponins were identified and some of them including notoginsenoside R1, ginsenoside Rb1, and ginsenoside Rg1 were researched frequently in the area of cardiovascular protection. However, the protective effects of PNS on cardiovascular diseases based on experimental studies and its underlying mechanisms have not been reviewed systematically. This paper reviewed the pharmacology of PNS and its monomers Rb1, Rg1, and R1 in the treatment for cardiovascular diseases.

  11. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    Science.gov (United States)

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  12. Perceval S aortic valve implantation in an achondroplastic Dwarf

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  13. Perceval S aortic valve implantation in an achondroplastic Dwarf.

    Science.gov (United States)

    Baikoussis, Nikolaos G; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  14. Valve-aided twisted Savonius rotor

    Energy Technology Data Exchange (ETDEWEB)

    Jaya Rajkumar, M.; Saha, U.K.

    2006-05-15

    Accessories, such as end plates, deflecting plates, shielding and guide vanes, may increase the power of a Savonius rotor, but make the system structurally complex. In such cases, the rotor can develop a relatively large torque at small rotational speeds and is cheap to build, however it harnesses only a small fraction of the incident wind energy. Another proposition for increasing specific output is to place non-return valves inside the concave side of the blades. Such methods have been studied experimentally with a twisted-blade Thus improving a Savonius rotor's energy capture. This new concept has been named as the 'Valve-Aided Twisted Savonius'rotor. Tests were conducted in a low-speed wind tunnel to evaluate performance. This mechanism is found to be independent of flow direction, and shows potential for large machines. [Author].

  15. Identification of black-box linear models : the case of thermal periodic contact of exhaust valves in internal combustion engines

    Energy Technology Data Exchange (ETDEWEB)

    Shojaeefard, M.H.; Fazelpour, M. [Iran Univ. of Science and Technology, Tehran (Iran, Islamic Republic of). Dept. of Automotive Engineering; Goudarzi, K. [Iran Univ. of Science and Technology, Tehran (Iran, Islamic Republic of). Dept. of Mechanical Engineering

    2009-07-01

    In internal combustion engines, hot exhaust gases that pass through the exhaust valve lead to high temperatures in the exhaust valve and the valve seat. Heat must be transferred from the exhaust valve to valve seat as they come in contact with each other during the opening and closing cycle in order to avoid damaging the exhaust valve. The heat transfer rate from the valve to valve seat is a function of many factors, including the thermal contact conductance (TCC) between the valve and valve seat. The objective of this study was to experimentally calculate the TCC for six different frequencies in the quasi-steady-state condition and also to obtain a transfer function to estimate the exhaust valve temperature by using black-box models of system identification. Periodic contact was taken into consideration in the study. The paper presented the experimental setup including the loading system, heat and cooling system, temperature measurement system, specimens properties, and data acquisition system. The paper also described the test procedure and experimental results. System identification was also described. It was concluded that the TCC decreased as the frequency of contact increased. The temperature transfer function was calculated by using the system identification method and having the temperatures at both sides of the contact surface. By knowing the temperature of one rod, the temperature of the other rod was estimated with high accuracy. 16 refs., 4 tabs., 7 figs.

  16. Respiratory disease in ball pythons (Python regius) experimentally infected with ball python nidovirus.

    Science.gov (United States)

    Hoon-Hanks, Laura L; Layton, Marylee L; Ossiboff, Robert J; Parker, John S L; Dubovi, Edward J; Stenglein, Mark D

    2018-04-01

    Circumstantial evidence has linked a new group of nidoviruses with respiratory disease in pythons, lizards, and cattle. We conducted experimental infections in ball pythons (Python regius) to test the hypothesis that ball python nidovirus (BPNV) infection results in respiratory disease. Three ball pythons were inoculated orally and intratracheally with cell culture isolated BPNV and two were sham inoculated. Antemortem choanal, oroesophageal, and cloacal swabs and postmortem tissues of infected snakes were positive for viral RNA, protein, and infectious virus by qRT-PCR, immunohistochemistry, western blot and virus isolation. Clinical signs included oral mucosal reddening, abundant mucus secretions, open-mouthed breathing, and anorexia. Histologic lesions included chronic-active mucinous rhinitis, stomatitis, tracheitis, esophagitis and proliferative interstitial pneumonia. Control snakes remained negative and free of clinical signs throughout the experiment. Our findings establish a causal relationship between nidovirus infection and respiratory disease in ball pythons and shed light on disease progression and transmission. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p day device safety, success, and efficacy were noted in 79.1%, 89...

  18. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms • Accurate Diagnosis • Treatment Options • Recovery and ...

  19. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  20. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  1. Suppression of inflammatory immune responses in celiac disease by experimental hookworm infection.

    Directory of Open Access Journals (Sweden)

    Henry J McSorley

    Full Text Available We present immunological data from two clinical trials where the effect of experimental human hookworm (Necator americanus infection on the pathology of celiac disease was evaluated. We found that basal production of Interferon- (IFN-γ and Interleukin- (IL-17A from duodenal biopsy culture was suppressed in hookworm-infected participants compared to uninfected controls. Increased levels of CD4+CD25+Foxp3+ cells in the circulation and mucosa are associated with active celiac disease. We show that this accumulation also occurs during a short-term (1 week oral gluten challenge, and that hookworm infection suppressed the increase of circulating CD4+CD25+Foxp3+ cells during this challenge period. When duodenal biopsies from hookworm-infected participants were restimulated with the immunodominant gliadin peptide QE65, robust production of IL-2, IFN-γ and IL-17A was detected, even prior to gluten challenge while participants were strictly adhering to a gluten-free diet. Intriguingly, IL-5 was produced only after hookworm infection in response to QE65. Thus we hypothesise that hookworm-induced TH2 and IL-10 cross-regulation of the TH1/TH17 inflammatory response may be responsible for the suppression of these responses during experimental hookworm infection.

  2. Mesenchymal Stem Cells in Restoration of Fertility at Experimental Pelvic Inflammatory Disease

    Directory of Open Access Journals (Sweden)

    Nataliia Volkova

    2017-01-01

    Full Text Available Inflammatory disorders account for a significant percentage of gynecologic diseases, particularly in women of reproductive age. It is known that stem cells have anti-inflammatory and regenerative properties. Based on this, we investigated the effect of intravenous administration of cryopreserved mesenchymal stem cells (cMSCs of bone marrow on experimental chronic inflammation of the ovaries. The paper shows that on the 21st day after cMSC therapy, leukocyte infiltration of ovaries was slightly relative to the control group without treatment, and the ratio of developing and atretic follicles in the animals with cMSC injection dramatically increased, while in the control, it still remained on the side of atretic forms. The number of apoptotic oocytes after stimulation of superovulation in the control group was significantly higher (85.3 ± 5.2% than that in the animals with therapy (5.7 ± 0.8%. Relative number of fertilized eggs in the group with cMSC therapy was higher by 40% compare to that in the control. Pregnancy rate in natural estrous cycle after cell administration increased by 20%, and average number of litters in this group was two times significantly higher than that in the control. So the intravenous injection of cMSCs has the restorative effect on the fertility at experimental pelvic inflammatory disease.

  3. Transcatheter aortic valve implantation and cerebrovascular accidents.

    Science.gov (United States)

    Stortecky, Stefan; Wenaweser, Peter; Windecker, Stephan

    2012-09-01

    Transcatheter aortic valve implantation (TAVI) is an evidence-based treatment alternative for selected high-risk patients with symptomatic severe aortic stenosis as acknowledged in the most recent edition of the ESC Guidelines on Valvular Heart Disease 2012. However, periprocedural complications and in particular cerebrovascular accidents remain a matter of concern. While transcatheter heart valve technology continuously improves and the development of novel and even less invasive implantation techniques is on-going, cerebrovascular events complicating TAVI may abrogate the usual improvement in terms of prognosis and quality of life. This article describes the incidence of cerebrovascular events after cardiovascular procedures, provides an overview of the pathophysiological mechanisms as well as the impact on outcomes and provides some insights into preventive strategies as well as the acute management of these events.

  4. Late presentation of posterior urethral valves.

    Science.gov (United States)

    Jalbani, Imran Khan; Biyabani, Syed Raziuddin

    2014-05-01

    Presence of posterior urethral valves (PUV) is the most common cause of urinary tract obstruction in the male neonate. Late presentation occurs in 10% of cases. We present a case of PUVs in an adult male who presented with history of obstructive lower urinary tract symptoms and hematuria. On evaluation, he was found to have raised serum creatinine level. A voiding cystourethrogram (VCUG) could not be completely performed because of narrowing in the posterior urethra. A rigid urethrocystoscopy was performed at which he was found to have type-I posterior urethral valve which were fulgurated. A repeat uroflowmetry revealed maximum flow rate of 12 ml/second. This case highlights that PUVs is not solely a disease of infancy but may also present late. VCUG is the radiological investigation of choice but the diagnosis may be missed. A urethrocystoscopy is advised if there is a high index of suspicion.

  5. The Diagnosis of Internal Leakage of Control Valve Based on the Grey Correlation Analysis Method

    Directory of Open Access Journals (Sweden)

    Zheng DING

    2014-07-01

    Full Text Available The valve plays an important part in the industrial automation system. Whether it operates normally or not relates with the quality of the products directly while its faults are relatively common because of bad working conditions. And the internal leakage is one of the common faults. Consequently, this paper sets up the experimental platform to make the valve in different working condition and collect relevant data online. Then, diagnose the internal leakage of the valve by using the grey correlation analysis method. The results show that this method can not only diagnose the internal leakage of valve accurately, but also distinguish fault degree quantitatively.

  6. Integrated nozzle - flapper valve with piezoelectric actuator and isothermal chamber: a feedback linearization multi control device

    Energy Technology Data Exchange (ETDEWEB)

    Kamali, Mohammadreza; Jazayeri, Seyed Ali [K. N.Toosi University of Technology, Tehran (Iran, Islamic Republic of); Najafi, Farid [University of Guilan, Rasht (Iran, Islamic Republic of); Kawashima, Kenji [Tokyo Medical and Dental University, Tokyo (Japan); Kagawa, Toshiharu [Tokyo Institute of Technology, Tokyo (Japan)

    2016-05-15

    This paper introduces a new nozzle-flapper valve with isothermal chamber using piezoelectric actuator. It controls the pressure and flow rate simply, effectively and separately. The proposed valve uses isothermal chamber presenting practical isothermal condition due to its large heat transfer interfaces filled by metal wool. The valve uses stacked type piezoelectric actuator with unique advantages. By using this valve, a simple method has been fulfilled to control flow rate or pressure of ideal gases in a pneumatic actuators. Experimental results demonstrated applications of the proposed valve to control either pressure or flow rate in pneumatic circuits. This valve can be also used in the pilot stage valve to actuate the main stage of a much bigger pneumatic valve. Designated structure contains only one pressure sensor installed on the isothermal control chamber, capable of controlling both pressure and flow rate. The desired output mass flow rate of the valve is controlled by the pressure changes during positioning of piezoelectric actuator at proper position. The proposed valve can control steady and unsteady oscillatory flow rate and pressure effectively, using nonlinear control method such as feedback linearization approach. Its effectiveness is demonstrated and validated through simulation and experiments.

  7. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  8. Voluntary wheel running delays disease onset and reduces pain hypersensitivity in early experimental autoimmune encephalomyelitis (EAE).

    Science.gov (United States)

    Benson, Curtis; Paylor, John W; Tenorio, Gustavo; Winship, Ian; Baker, Glen; Kerr, Bradley J

    2015-09-01

    Multiple sclerosis (MS) is classically defined by motor deficits, but it is also associated with the secondary symptoms of pain, depression, and anxiety. Up to this point modifying these secondary symptoms has been difficult. There is evidence that both MS and the animal model experimental autoimmune encephalomyelitis (EAE), commonly used to study the pathophysiology of the disease, can be modulated by exercise. To examine whether limited voluntary wheel running could modulate EAE disease progression and the co-morbid symptoms of pain, mice with EAE were allowed access to running wheels for 1h every day. Allowing only 1h every day of voluntary running led to a significant delay in the onset of clinical signs of the disease. The development of mechanical allodynia was assessed using Von Frey hairs and indicated that wheel running had a modest positive effect on the pain hypersensitivity associated with EAE. These behavioral changes were associated with reduced numbers of cFOS and phosphorylated NR1 positive cells in the dorsal horn of the spinal cord compared to no-run EAE controls. In addition, within the dorsal horn, voluntary wheel running reduced the number of infiltrating CD3(+) T-cells and reduced the overall levels of Iba1 immunoreactivity. Using high performance liquid chromatography (HPLC), we observed that wheel-running lead to significant changes in the spinal cord levels of the antioxidant glutathione. Oxidative stress has separately been shown to contribute to EAE disease progression and neuropathic pain. Together these results indicate that in mice with EAE, voluntary motor activity can delay the onset of clinical signs and reduce pain symptoms associated with the disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Exercise training reverses skeletal muscle atrophy in an experimental model of VCP disease.

    Directory of Open Access Journals (Sweden)

    Angèle Nalbandian

    Full Text Available The therapeutic effects of exercise resistance and endurance training in the alleviation of muscle hypertrophy/atrophy should be considered in the management of patients with advanced neuromuscular diseases. Patients with progressive neuromuscular diseases often experience muscle weakness, which negatively impact independence and quality of life levels. Mutations in the valosin containing protein (VCP gene lead to Inclusion body myopathy associated with Paget's disease of bone and frontotemporal dementia (IBMPFD and more recently affect 2% of amyotrophic lateral sclerosis (ALS-diagnosed cases.The present investigation was undertaken to examine the effects of uphill and downhill exercise training on muscle histopathology and the autophagy cascade in an experimental VCP mouse model carrying the R155H mutation. Progressive uphill exercise in VCP(R155H/+ mice revealed significant improvement in muscle strength and performance by grip strength and Rotarod analyses when compared to the sedentary mice. In contrast, mice exercised to run downhill did not show any significant improvement. Histologically, the uphill exercised VCP(R155H/+ mice displayed an improvement in muscle atrophy, and decreased expression levels of ubiquitin, P62/SQSTM1, LC3I/II, and TDP-43 autophagy markers, suggesting an alleviation of disease-induced myopathy phenotypes. There was also an improvement in the Paget-like phenotype.Collectively, our data highlights that uphill exercise training in VCP(R155H/+ mice did not have any detrimental value to the function of muscle, and may offer effective therapeutic options for patients with VCP-associated diseases.

  10. Monkeypox disease transmission in an experimental setting: prairie dog animal model.

    Directory of Open Access Journals (Sweden)

    Christina L Hutson

    Full Text Available Monkeypox virus (MPXV is considered the most significant human public health threat in the genus Orthopoxvirus since the eradication of variola virus (the causative agent of smallpox. MPXV is a zoonotic agent endemic to forested areas of Central and Western Africa. In 2003, MPXV caused an outbreak in the United States due to the importation of infected African rodents, and subsequent sequential infection of North American prairie dogs (Cynomys ludovicianus and humans. In previous studies, the prairie dog MPXV model has successfully shown to be very useful for understanding MPXV since the model emulates key characteristics of human monkeypox disease. In humans, percutaneous exposure to animals has been documented but the primary method of human-to-human MPXV transmission is postulated to be by respiratory route. Only a few animal model studies of MPXV transmission have been reported. Herein, we show that MPXV infected prairie dogs are able to transmit the virus to naive animals through multiple transmission routes. All secondarily exposed animals were infected with MPXV during the course of the study. Notably, animals secondarily exposed appeared to manifest more severe disease; however, the disease course was very similar to those of experimentally challenged animals including inappetence leading to weight loss, development of lesions, production of orthopoxvirus antibodies and shedding of similar levels or in some instances higher levels of MPXV from the oral cavity. Disease was transmitted via exposure to contaminated bedding, co-housing, or respiratory secretions/nasal mucous (we could not definitively say that transmission occurred via respiratory route exclusively. Future use of the model will allow us to evaluate infection control measures, vaccines and antiviral strategies to decrease disease transmission.

  11. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  12. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  13. Alveolar bone loss and mineralization in the pig with experimental periodontal disease

    Directory of Open Access Journals (Sweden)

    Mandee Yang

    2018-03-01

    Full Text Available Objective: To address how experimental periodontal disease affects alveolar bone mass and mineral apposition in a young pig model. Materials and methods: Seven three-month-old pigs were periodically inoculated with 4 types of periodontal bacteria, along with a ligature around the last maxillary deciduous molar for 8 weeks to induce periodontal disease (PG. Eight same-aged pigs served as the control (CG. Segmentations of 3D cone-beam CT images were performed to quantify volumes of the total alveolar bone, alveolar ridge, and all roots of the target molar. Calcein and alizarin were administered for labeling mineral apposition before euthanasia. The harvested molar blocks were sectioned and examined under epifluorescence. The inter-label distance between the two vital markers at regional bone surfaces were measured and mineral apposition rate (MAR was calculated. Results: A significant reduction of total alveolar bone volume was seen in PG with the major loss at the alveolar ridge. MAR was significantly higher at the root furcation region than those at both buccal and palatal ridges in CG. Compared with CG, PG animals showed more interrupted labeled bands with significantly lower MAR at the furcation region. MARs were positively associated with both the volumes of total alveolar bone and ridge in CG, but only with the total alveolar bone in PG. Conclusions: In young growing pigs, mineral apposition is region specific. The experimental periodontal disease not only leads to alveolar bone loss, but also perturbs mineral apposition for new bone formation, thus impairing the homeostasis of alveolar bone remodeling. Keyword: Dentistry

  14. BNGS B valve packing program

    International Nuclear Information System (INIS)

    Cumming, D.

    1995-01-01

    The Bruce B Valve Packing Program began in 1987. The early history and development were presented at the 1992 International CANDU Maintenance conference. This presentation covers the evolution of the Bruce B Valve Packing Program over the period 1992 to 1995. (author)

  15. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time.

  16. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    International Nuclear Information System (INIS)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y.

    2014-01-01

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time

  17. Behavioural alterations are independent of sickness behaviour in chronic experimental Chagas disease.

    Science.gov (United States)

    Vilar-Pereira, Glaucia; Ruivo, Leonardo Alexandre de Souza; Lannes-Vieira, Joseli

    2015-12-01

    The existence of the nervous form of Chagas disease is a matter of discussion since Carlos Chagas described neurological disorders, learning and behavioural alterations in Trypanosoma cruzi-infected individuals. In most patients, the clinical manifestations of the acute phase, including neurological abnormalities, resolve spontaneously without apparent consequence in the chronic phase of infection. However, chronic Chagas disease patients have behavioural changes such as psychomotor alterations, attention and memory deficits, and depression. In the present study, we tested whether or not behavioural alterations are reproducible in experimental models. We show that C57BL/6 mice chronically infected with the Colombian strain of T. cruzi (150 days post-infection) exhibit behavioural changes as (i) depression in the tail suspension and forced swim tests, (ii) anxiety analysed by elevated plus maze and open field test sand and (iii) motor coordination in the rotarod test. These alterations are neither associated with neuromuscular disorders assessed by the grip strength test nor with sickness behaviour analysed by temperature variation sand weight loss. Therefore, chronically T. cruzi-infected mice replicate behavioural alterations (depression and anxiety) detected in Chagas disease patients opening an opportunity to study the interconnection and the physiopathology of these two biological processes in an infectious scenario.

  18. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Long-Term Results of Mitral Valve Repair

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Current guidelines state that patients with severe mitral regurgitation should be treated in reference centers with a high reparability rate, low mortality rate, and durable results. Objective: To analyze our global experience with the treatment of organic mitral regurgitation from various etiologies operated in a single center. Methods: We evaluated all surgically treated patients with organic mitral regurgitation from 2004-2017. Patients were evaluated clinically and by echocardiography every year. We determined early and late survival rates, valve related events and freedom from recurrent mitral regurgitation and tricuspid regurgitation. Valve failure was defined as any mitral regurgitation ≥ moderate degree or the need for reoperation for any reason. Results: Out of 133 patients with organic mitral regurgitation, 125 (93.9% were submitted to valve repair. Mean age was 57±15 years and 52 patients were males. The most common etiologies were degenerative disease (73 patients and rheumatic disease (34 patients. Early mortality was 2.4% and late survival was 84.3% at 10 years, which are similar to the age- and gender-matched general population. Only two patients developed severe mitral regurgitation, and both were reoperated (95.6% at 10 years. Freedom from mitral valve failure was 84.5% at 10 years, with no difference between degenerative and rheumatic valves. Overall, late ≥ moderate tricuspid regurgitation was present in 34% of the patients, being more common in the rheumatic ones. The use of tricuspid annuloplasty abolished this complication. Conclusion: We have demonstrated that mitral regurgitation due to organic mitral valve disease from various etiologies can be surgically treated with a high repair rate, low early mortality and long-term survival that are comparable to the matched general population. Concomitant treatment of atrial fibrillation and tricuspid valve may be important adjuncts to optimize long

  20. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)