WorldWideScience

Sample records for experimental performance evaluation

  1. Experimental evaluation of solar still performance

    Energy Technology Data Exchange (ETDEWEB)

    Saif-ur-Rehman, M

    1973-01-01

    A method is described to measure various temperatures, insolation, and the distillate outputs from various stills simultaneously. The experimental results are used to study the thermodynamic behavior of solar still performance with the help of temperature profiles of saline water, underneath soil and glass. Effects of ageing on material deterioration and still output are discussed and in the light of the experimental evidence, recommendations are made for better still performance.

  2. Performance Evaluation of an Experimental Turbojet Engine

    Science.gov (United States)

    Ekici, Selcuk; Sohret, Yasin; Coban, Kahraman; Altuntas, Onder; Karakoc, T. Hikmet

    2017-11-01

    An exergy analysis is presented including design parameters and performance assessment, by identifying the losses and efficiency of a gas turbine engine. The aim of this paper is to determine the performance of a small turbojet engine with an exergetic analysis based on test data. Experimental data from testing was collected at full-load of small turbojet engine. The turbojet engine exhaust data contains CO2, CO, CH4, H2, H2O, NO, NO2, N2 and O2 with a relative humidity of 35 % for the ambient air of the performed experiments. The evaluated main components of the turbojet engine are the air compressor, the combustion chamber and the gas turbine. As a result of the thermodynamic analysis, exergy efficiencies (based on product/fuel) of the air compressor, the combustion chamber and the gas turbine are 81.57 %, 50.13 % and 97.81 %, respectively. A major proportion of the total exergy destruction was found for the combustion chamber at 167.33 kW. The exergy destruction rates are 8.20 %, 90.70 % and 1.08 % in the compressor, the combustion chamber and the gas turbine, respectively. The rates of exergy destruction within the system components are compared on the basis of the exergy rate of the fuel provided to the engine. Eventually, the exergy rate of the fuel is calculated to be 4.50 % of unusable due to exergy destruction within the compressor, 49.76 % unusable due to exergy destruction within the combustion chamber and 0.59 % unusable due to exergy destruction within the gas turbine. It can be stated that approximately 55 % of the exergy rate of the fuel provided to the engine can not be used by the engine.

  3. Fuel performance evaluation for the CAFE experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Hirota, Leandro T.

    2011-01-01

    Fuel rod cladding material is the second barrier to prevent the release of radioactive inventories in a PWR reactor. In this sense, an important safety aspect is to assess the fuel behavior under operational conditions. This can be made by means of fuel performance codes and confirmed by experimental measurements. In order to evaluate the fuel behavior of fuel rods in steady-state conditions, it was designed an experimental irradiation device, the Nuclear Fuel Irradiation Circuit (CAFE-Mod1). This device will allow controlling the surface rod temperature, to measure the power associated to the rod and the evolution of fission gas release for a typical PWR fuel pin. However, to support the experimental irradiation program, it is extremely important to simulate the experimental conditions using a fuel performance code. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior during the irradiation program. This evaluation was carried out by means of an adapted fuel performance code. Obtained results have shown that besides of the variation observed for parameters, such as, fuel temperature and fission gas release as a function of fuel enrichment level, the fuel rod integrity was preserved in all studied conditions. (author)

  4. Experimental Facilities for Performance Evaluation of Fast Reactor Components

    International Nuclear Information System (INIS)

    Chandramouli, S.; Kumar, V.A. Suresh; Shanmugavel, M.; Vijayakumar, G.; Vinod, V.; Noushad, I.B.; Babu, B.; Kumar, G. Padma; Nashine, B.K.; Rajan, K.K.

    2013-01-01

    Brief details about various experimental facilities catering to the testing and performance evaluation requirements of fast reactor components have been brought out. These facilities have been found to be immensely useful to continue research and development activities in the areas of component development and testing, sodium technology, thermal hydraulics and sodium instrumentation for the SFR’s. In addition new facilities which have been planned will be of great importance for the developmental activities related to future SFR’s

  5. Experimental evaluation of sodium to air heat exchanger performance

    International Nuclear Information System (INIS)

    Vinod, V.; Pathak, S.P.; Paunikar, V.D.; Suresh Kumar, V.A.; Noushad, I.B.; Rajan, K.K.

    2013-01-01

    Highlights: ► Sodium to air heat exchangers are used to remove the decay heat produced in fast breeder reactor after shutdown. ► Finned tube sodium to air heat exchanger with sodium on tube side was tested for its heat transfer performance. ► A one dimensional computer code was validated by the experimental data obtained. ► Non uniform sodium and air flow distribution was present in the heat exchanger. - Abstract: Sodium to air heat exchangers (AHXs) is used in Prototype Fast Breeder Reactor (PFBR) circuits to reject the decay heat produced by the radioactive decay of the fission products after reactor shutdown, to the atmospheric air. The heat removal through sodium to air heat exchanger maintains the temperature of reactor components in the pool within safe limits in case of non availability of normal heat transport path. The performance of sodium to air heat exchanger is very critical to ensure high reliability of the decay heat removal systems in sodium cooled fast breeder reactors. Hence experimental evaluation of the adequacy of the heat transfer capability gives confidence to the designers. A finned tube cross flow sodium to air heat exchanger of 2 MW heat transfer capacity with sodium on tube side and air on shell side was tested in the Steam Generator Test Facility at Indira Gandhi Center for Atomic Research, India. Heat transfer experiments were carried out with forced circulation of sodium and air, which confirmed the adequacy of heat removal capacity of the heat exchanger. The testing showed that 2.34 MW of heat power is transferred from sodium to air at nominal flow and temperature conditions. A one dimensional computer code developed for design and analysis of the sodium to air heat exchanger was validated by the experimental data obtained. An equivalent Nusselt number, Nu eq is derived by approximating that the resistance of heat transfer from sodium to air is contributed only by the film resistance of air. The variation of Nu eq with respect

  6. Solar power plant performance evaluation: simulation and experimental validation

    International Nuclear Information System (INIS)

    Natsheh, E M; Albarbar, A

    2012-01-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P and O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  7. Solar power plant performance evaluation: simulation and experimental validation

    Science.gov (United States)

    Natsheh, E. M.; Albarbar, A.

    2012-05-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  8. Advanced Computational and Experimental Techniques for Nacelle Liner Performance Evaluation

    Science.gov (United States)

    Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.; Nark, Douglas

    2009-01-01

    The Curved Duct Test Rig (CDTR) has been developed to investigate sound propagation through a duct of size comparable to the aft bypass duct of typical aircraft engines. The axial dimension of the bypass duct is often curved and this geometric characteristic is captured in the CDTR. The semiannular bypass duct is simulated by a rectangular test section in which the height corresponds to the circumferential dimension and the width corresponds to the radial dimension. The liner samples are perforate over honeycomb core and are installed on the side walls of the test section. The top and bottom surfaces of the test section are acoustically rigid to simulate a hard wall bifurcation or pylon. A unique feature of the CDTR is the control system that generates sound incident on the liner test section in specific modes. Uniform air flow, at ambient temperature and flow speed Mach 0.275, is introduced through the duct. Experiments to investigate configuration effects such as curvature along the flow path on the acoustic performance of a sample liner are performed in the CDTR and reported in this paper. Combinations of treated and acoustically rigid side walls are investigated. The scattering of modes of the incident wave, both by the curvature and by the asymmetry of wall treatment, is demonstrated in the experimental results. The effect that mode scattering has on total acoustic effectiveness of the liner treatment is also shown. Comparisons of measured liner attenuation with numerical results predicted by an analytic model based on the parabolic approximation to the convected Helmholtz equation are reported. The spectra of attenuation produced by the analytic model are similar to experimental results for both walls treated, straight and curved flow path, with plane wave and higher order modes incident. The numerical model is used to define the optimized resistance and reactance of a liner that significantly improves liner attenuation in the frequency range 1900-2400 Hz. A

  9. Experimental Evaluation of Installed Cooking Exhaust Fan Performance

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Delp, William W.; Apte, Michael G.

    2010-11-01

    The installed performance of cooking exhaust fans was evaluated through residential field experiments conducted on a sample of 15 devices varying in design and other characteristics. The sample included two rear downdraft systems, two under-cabinet microwave over range (MOR) units, three different installations of an under-cabinet model with grease screens across the bottom and no capture hood, two devices with grease screens covering the bottom of a large capture hood (one under-cabinet, one wall-mount chimney), four under-cabinet open hoods, and two open hoods with chimney mounts over islands. Performance assessment included measurement of airflow and sound levels across fan settings and experiments to quantify the contemporaneous capture efficiency for the exhaust generated by natural gas cooking burners.Capture efficiency is defined as the fraction of generated pollutants that are removed through the exhaust and thus not available for inhalation of household occupants. Capture efficiency (CE) was assessed for various configurations of burner use (e.g., single front, single back, combination of one front and one back, oven) and fan speed setting. Measured airflow rates were substantially lower than the levels noted in product literature for many of the units. This shortfall was observed for several units costing in excess of $1000. Capture efficiency varied widely (from<5percent to roughly 100percent) across devices and across conditions for some devices. As expected, higher capture efficiencies were achieved with higher fan settings and the associated higher air flow rates. In most cases, capture efficiencies were substantially higher for rear burners than for front burners. The best and most consistent performance was observed for open hoods that covered all cooktop burners and operated at higher airflow rates. The lowest capture efficiencies were measured when a front burner was used with a rear backdraft system or with lowest fan setting for above the range

  10. Experimental performance evaluation of sintered Gd spheres packed beds

    DEFF Research Database (Denmark)

    Tura, A.; Nielsen, Klaus K.; Van Nong, Ngo

    2016-01-01

    Research in magnetic refrigeration heavily relies on the use of packed spheres in regenerators, however little investigation to verify that such non-monolithic arrangements guarantee a sufficiently constrained structure has yet been performed. This work presents a preliminary comparison of the pe......Research in magnetic refrigeration heavily relies on the use of packed spheres in regenerators, however little investigation to verify that such non-monolithic arrangements guarantee a sufficiently constrained structure has yet been performed. This work presents a preliminary comparison...... of the performance of AMRs consisting of Gd spheres with diameters ranging from 450-550 microns partially sintered by Spark Plasma Sintering (SPS) to similar spheres, sorted in the same size range and from the same batch, but merely packed. Pressure drop is compared at uniform temperature and at a range of heat...

  11. Evaluation of fuel performance with different enrichment degrees for an experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Pino, Eddy S.; Gomes, Daniel S.; Abe, Alfredo Y.; Silva, Antonio Teixeira e

    2013-01-01

    Evaluation of fuel performance is conventionally carried out using specific codes developed to this aim. The obtained data are confirmed by experimental measurements performed using devices, which are located inside research reactors, projected to simulate reactor conditions under normal operation. Due to the limitations of the available reactor core length for irradiation in research reactors core, fuel rods used to obtain experimental data must present the same characteristics of the real fuel rod, but with a shorter length. Then, in order to compare the obtained results to the expected behavior of the real fuel rod, the experimental fuel rod should be designed with a free volume to fuel volume ratio very closed to the one of the full scale fuel rod. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior in a rod applied to the experimental irradiation device called Nuclear Fuel Irradiation Circuit (CAFE-Mod1) considering two fuel enrichment degrees: a typical commercial PWR enrichment and a value about 4 times higher. This evaluation is carried out by means of an adapted fuel performance code. Some of the parameter evaluated were fuel temperature and fission gas release as function of the fuel enrichment level. The results obtained in this paper were very similar to the ones previously obtained without consider similar free volume between the experimental and the full length fuel rod, regardless of low increases observed for the internal rod pressure and the amount of fission gas released. (author)

  12. Experimental evaluation of user performance in a pursuit tracking task with multimodal feedback

    Directory of Open Access Journals (Sweden)

    Obrenović Željko

    2004-01-01

    Full Text Available In this paper we describe the results of experimental evaluation of user performance in a pursuit-tracking task with multimodal feedback. Our experimental results indicate that audio can significantly improve the accuracy of pursuit tracking. Experiments with 19 participants have shown that addition of acoustic modalities reduces the error during pursuit tracking for up to 19%. Moreover, experiments indicated the existence of perceptual boundaries of multimodal HCI for different scene complexity and target speeds. We have also shown that the most appealing paradigms are not the most effective ones, which necessitates a careful quantitative analysis of proposed multimodal HCI paradigms.

  13. An experimental evaluation of the performance deficit of an aircraft engine starter turbine

    Science.gov (United States)

    Haas, J. E.; Roelke, R. J.; Hermann, P.

    1980-01-01

    An experimental investigation is presented to determine the aerodynamic performance deficit of a 13.5 - centimeter-tip-diameter aircraft engine starter turbine. The two-phased evaluation comprised both the stator and the stage performance, and the experimental design is described in detail. Data obtained from the investigation of three honeycomb shrouds clearly showed that the filled honeycomb reached a total efficiency of 0.868, 8.2 points higher than the open honeycomb shroud, at design equivalent conditions of speed and blade-jet speed ratio. It was concluded that the use of an open honeycomb shroud caused the large performance deficit for the starter turbine. Further research is suggested to ascertain stator inlet boundary layer measurements.

  14. Experimental Flow Performance Evaluation of novel miniaturized Advanced Piezoelectric Dual Cooling Jet

    International Nuclear Information System (INIS)

    De Bock, H P J; Whalen, B P; Chamarthy, P; Jackson, J L

    2012-01-01

    In recent years, electronics systems have significantly reduced in size at maintained or increased functionality. This trend has led to an increased demand for smaller and more capable thermal management. However, miniaturization of conventional fan and heat sink cooling systems introduce significant size, weight and efficiency challenges. In this study the flow performance of a novel alternative thin form-factor cooling solution, the advanced piezoelectric dual cooling jet(DCJ), is evaluated. A DCJ is a system where two piezoelectric actuators are excited to produce air flow. The total height of the device is about 1mm. The design of the experimental method for evaluating the equivalent fan-curve of the DCJ device is described in detail. Experimental results in comparison to conventional fan solutions are provided. The DCJ is expected to be a good candidate for thermal management in next generation thin profile consumer electronics.

  15. Experimental performance evaluation of two stack sampling systems in a plutonium facility

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1992-04-01

    The evaluation of two routine stack sampling systems at the Z-Plant plutonium facility operated by Rockwell International for USERDA is part of a larger study, sponsored by Rockwell and conducted by Battelle, Pacific Northwest Laboratories, of gaseous effluent sampling systems. The gaseous effluent sampling systems evaluated are located at the main plant ventilation stack (291-Z-1) and at a vessel vent stack (296-Z-3). A preliminary report, which was a paper study issued in April 1976, identified many deficiencies in the existing sampling systems and made recommendations for corrective action. The objectives of this experimental evaluation of those sampling systems were as follows: Characterize the radioactive aerosols in the stack effluents; Develop a tracer aerosol technique for validating particulate effluent sampling system performance; Evaluate the performance of the existing routine sampling systems and their compliance with the sponsor's criteria; and Recommend corrective action where required. The tracer aerosol approach to sampler evaluation was chosen because the low concentrations of radioactive particulates in the effluents would otherwise require much longer sampling times and thus more time to complete this evaluation. The following report describes the sampling systems that are the subject of this study and then details the experiments performed. The results are then presented and discussed. Much of the raw and finished data are included in the appendices

  16. Experimental study for flow characteristics and performance evaluation of butterfly valves

    International Nuclear Information System (INIS)

    Kim, C K; Shin, M S; Yoon, J Y

    2010-01-01

    The industrial butterfly valves have been applied to transport a large of fluid with various fields of industry. Also, these are mainly used a control of fluid flux to the water and waste-water pipeline. Present, butterfly valves are manufacturing for multiplicity shape of bodies and discs with many producers. However, appropriate performance evaluation was not yet accomplished to compare about these valves through experiments. This study is performed the experiment of flow characteristics and performance of manufactured 400A butterfly valves for the water and waste pipeline, and compared experimental results. We performed experiments that were controlled fixed a differential pressure condition (1 psi) and the range of the flow rate conditions (500 m 3 /hr ∼ 2500 m 3 /hr), and also opened the disc of valves to a range of angle from 9 degree to 90 degree. We investigated and compared the valve flow coefficient and the valve loss coefficient of results through experiments with each butterfly valve.

  17. Experimental analysis and performance evaluation of a tandem photovoltaic–thermoelectric hybrid system

    International Nuclear Information System (INIS)

    Kossyvakis, D.N.; Voutsinas, G.D.; Hristoforou, E.V.

    2016-01-01

    Highlights: • Experimental and theoretical investigation of a PV–TEG system has been conducted. • Poly-Si and dye-sensitized solar cells have been employed. • Thermoelectric generators of different thermoelement length have been tested. • A wide range considering cell’s operating temperature has been examined. - Abstract: Although photovoltaics have been established as the dominant technology considering the field of solar energy conversion systems, issues regarding their relatively low efficiency still remain practically unsolved. Very recently, the possibility of combining photovoltaic (PV) cells and thermoelectric generators (TEGs) in hybrid systems, as a means of improving the overall conversion efficiency, has attracted particular attention. In this paper, the performance of a tandem PV–TEG hybrid, employing poly-Si as well as dye-sensitized solar cells, has been examined experimentally. Thermoelectric devices of different thermoelement geometry have been tested in order to identify the corresponding performance effect. In addition, the outcomes of the experimental process have been exploited in order to evaluate the performance of the system under real operating conditions. The analysis conducted indicates that the utilization of TEGs with shorter thermoelements results in enhanced power output levels, when conditions of actual operation are considered. Moreover, although improved power output is obtained by the setup employing the polycrystalline cell, dye-sensitized technology could become particularly attractive when the incorporation of solar cells in PV–TEG hybrids operating under conditions of elevated temperature is examined.

  18. Experimental performance evaluation for a carbon dioxide light commercial cooling application under transcritical and subcritical conditions

    International Nuclear Information System (INIS)

    Boccardi, G.; Calabrese, N.; Celata, G.P.; Mastrullo, R.; Mauro, A.W.; Perrone, A.; Trinchieri, R.

    2013-01-01

    CO 2 is one of the most interesting non toxic, nor flammable, low GWP natural fluid to be used in applications with a large direct contribution to global warming, such as vending machines. In this paper the results of an experimental investigation on a small capacity, air-forced refrigerating plant working with CO 2 are presented. The air inlet temperatures at gas cooler and evaporator were varied between 16 °C and 31 °C and between −25 °C and 25 °C, respectively, to cover the range of temperatures under conditions typical of commercial refrigeration, during quasi-steady operation. The thermodynamic analysis of the system performance was carried on varying independently the pressure at the gas cooler, by overfeeding the liquid receiver to point out the effect of refrigerant charge. The results allow to describe the performance of the system in a map varying the boundary conditions; at the same time the corresponding variations of the thermodynamic cycle, the COP and the mass flow rate are reported. -- Highlights: ► A light commercial refrigerating plant working with CO 2 was tested in order to evaluate its performance. ► 71 experimental points were collected varying the flow rates, the temperatures of air sources and the refrigerant charge. ► Mass flow rate, cooling capacity, electrical power and COP were evaluated as a function of pressures and superheating. ► The segregate influence of each operating parameter on each performance indicator was calculated. ► A map of plant performance as a function of air source temperatures is reported

  19. Experimental evaluation of Diesel engine performance and emission using blends of jojoba oil and Diesel fuel

    International Nuclear Information System (INIS)

    Huzayyin, A.S.; Bawady, A.H.; Rady, M.A.; Dawood, A.

    2004-01-01

    An experimental evaluation of using jojoba oil as an alternate Diesel engine fuel has been conducted in the present work. Measurements of jojoba oil chemical and physical properties have indicated a good potential of using jojoba oil as an alternative Diesel engine fuel. Blending of jojoba oil with gas oil has been shown to be an effective method to reduce engine problems associated with the high viscosity of jojoba oil. Experimental measurements of different performance parameters of a single cylinder, naturally aspirated, direct injection, Diesel engine have been performed using gas oil and blends of gas oil with jojoba oil. Measurements of engine performance parameters at different load conditions over the engine speed range have generally indicated a negligible loss of engine power, a slight increase in brake specific fuel consumption and a reduction in engine NO x and soot emission using blends of jojoba oil with gas oil as compared to gas oil. The reduction in engine soot emission has been observed to increase with the increase of jojoba oil percentage in the fuel blend

  20. Experimental evaluation of diesel engine performance and emission using blends of jojoba oil and diesel fuel

    Energy Technology Data Exchange (ETDEWEB)

    Huzayyin, A.S.; Rady, M.A.; Dawood, A. [Benha High Inst. of Technology (Egypt). Dept. of Mechanical Engineering Technology; Bawady, A.H. [University of Ain Shams, Cairo (Egypt). Faculty of Engineering

    2004-08-01

    An experimental evaluation of using jojoba oil as an alternate diesel engine fuel has been conducted in the present work. Measurements of jojoba oil chemical and physical properties have indicated a good potential of using jojoba oil as an alternative diesel engine fuel. Blending of jojoba oil with gas oil has been shown to be an effective method to reduce engine problems associated with the high viscosity of jojoba oil. Experimental measurements of different performance parameters of a single cylinder, naturally aspirated, direct injection, diesel engine have been performed using gas oil and blends of gas oil with jojoba oil. Measurements of engine performance parameters at different load conditions over the engine speed range have generally indicated a negligible loss of engine power, a slight increase in brake specific fuel consumption and a reduction in engine NO{sub x} and soot emission using blends of jojoba oil with gas oil as compared to gas oil. The reduction in engine soot emission has been observed to increase with the increase of jojoba oil percentage in the fuel blend. (Author)

  1. Performance Evaluation of Large Aperture 'Polished Panel' Optical Receivers Based on Experimental Data

    Science.gov (United States)

    Vilnrotter, Victor

    2013-01-01

    Recent interest in hybrid RF/Optical communications has led to the development and installation of a "polished-panel" optical receiver evaluation assembly on the 34-meter research antenna at Deep-Space Station 13 (DSS-13) at NASA's Goldstone Communications Complex. The test setup consists of a custom aluminum panel polished to optical smoothness, and a large-sensor CCD camera designed to image the point-spread function (PSF) generated by the polished aluminum panel. Extensive data has been obtained via realtime tracking and imaging of planets and stars at DSS-13. Both "on-source" and "off-source" data were recorded at various elevations, enabling the development of realistic simulations and analytic models to help determine the performance of future deep-space communications systems operating with on-off keying (OOK) or pulse-position-modulated (PPM) signaling formats with photon-counting detection, and compared with the ultimate quantum bound on detection performance for these modulations. Experimentally determined PSFs were scaled to provide realistic signal-distributions across a photon-counting detector array when a pulse is received, and uncoded as well as block-coded performance analyzed and evaluated for a well-known class of block codes.

  2. Experimental and theoretical evaluation of the performance of a tar solar water heater

    International Nuclear Information System (INIS)

    Ammari, H.D.; Nimir, Y.L.

    2003-01-01

    The paper presents an experimental and theoretical evaluation of the performance of a tar solar water heater and comparison with that of a conventional type collector. The performance of both collectors is assessed under the same conditions. Both of the collectors have the same surface area and are glazed. The conventional type has the water tubes welded to the absorber plate, whereas in the tar type, the tar acts as an absorber plate that covers the water tubes. The theoretical model for each collector type, with the transient effects taken into account, is based on a control volume and a time base in the related energy equations. By considering a small element of the collector in each case, three partial differential equations were developed for each collector and were solved numerically by the Runge-Kutta method of the fifth order. A good agreement was achieved between the numerical and experimental results for both the conventional and tar collectors, indicating the feasibility of employing the theoretical model in the design of flat plate solar collectors. The results also showed that the conventional collector is more efficient than the tar type during most of the daylight, but the tar collector had the added advantage of better conservation of energy in late afternoon and evening

  3. A comparative and experimental evaluation of performance of stocked diploid and triploid brook trout

    Science.gov (United States)

    Budy, Phaedra E.; Thiede, G.P.; Dean, A.; Olsen, D.; Rowley, G.

    2012-01-01

    Despite numerous negative impacts, nonnative trout are still being stocked to provide economically and socially valuable sport fisheries in western mountain lakes. We evaluated relative performance and potential differences in feeding strategy and competitive ability of triploid versus diploid brook trout Salvelinus fontinalis in alpine lakes, as well as behavioral and performance differences of diploid and triploid brook trout in two controlled experimental settings: behavioral experiments in the laboratory and performance evaluations in ponds. Across lakes, catch per unit effort (CPUE) and relative weight (Wr ) were not significantly different between ploidy levels. Mean sizes were also similar between ploidy levels except in two of the larger lakes where diploids attained slightly larger sizes (approximately 20 mm longer). We observed no significant differences between diploids and triploids in diet, diet preference, or trophic structure. Similarly, growth and condition did not differ between ploidy levels in smaller-scale pond experiments, and aggressive behavior did not differ between ploidy levels (fed or unfed fish trials) in the laboratory. Independent of ploidy level, the relative performance of brook trout varied widely among lakes, a pattern that appeared to be a function of lake size or a factor that covaries with lake size such as temperature regime or carrying capacity. In summary, we observed no significant differences in the relative performance of brook trout from either ploidy level across a number of indices, systems, and environmental conditions, nor any indication that one group is more aggressive or a superior competitor than the other. Collectively, these results suggest that triploid brook trout will offer a more risk-averse and promising management opportunity when they are stocked to these lakes and elsewhere to simultaneously meet the needs for the sport fishery and conservation objectives.

  4. Performance of ultraviolet photocatalytic oxidation for indoor air applications: Systematic experimental evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Lexuan [Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, Quebec H3G 1M8 (Canada); Haghighat, Fariborz, E-mail: fariborz.haghighat@concordia.ca [Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, Quebec H3G 1M8 (Canada); Lee, Chang-Seo [Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, Quebec H3G 1M8 (Canada); Lakdawala, Ness [DECTRON International Inc., Montreal, Quebec (Canada)

    2013-10-15

    Highlights: • An innovative experimental set-up was designed and constructed for testing UV-PCO. • Test methodologies were developed to examine UV-PCO air cleaners for VOCs removal. • VOCs type, inlet concentration, flow rate, irradiance, and RH have influence on PCO. • Gas-phase ozonation with a variety of compounds was examined in a duct system. • Formation of by-products generated from incomplete conversion was investigated. -- Abstract: Photocatalytic oxidation (PCO) is a promising technology that has potential to be applied in mechanically ventilated buildings to improve indoor air quality (IAQ). However, the major research studies were done in bench-top scale reactors under ideal reaction conditions. In addition, no study has been carried out on the investigation of the ozonation and photolysis effect using a pilot duct system. The objective of this study is the development of methodologies to evaluate the performance of PCO systems. A systematic parametric evaluation of the effects of various kinetic parameters, such as compound's type, inlet concentration, airflow rate, light intensity, and relative humidity, was conducted, and new interpretations were provided from a fundamental analysis. In addition, the photolysis effect under vacuum ultraviolet (VUV) irradiation for a variety of volatile organic compounds (VOCs) was examined for the first time in a pilot duct system. The performance comparison of ultraviolet C (UVC)-PCO and VUV-PCO was also discussed due to the presence of ozone. Moreover, the formation of by-products generated with or without ozone generation was fully compared to evaluate the PCO technology.

  5. Performance of ultraviolet photocatalytic oxidation for indoor air applications: Systematic experimental evaluation

    International Nuclear Information System (INIS)

    Zhong, Lexuan; Haghighat, Fariborz; Lee, Chang-Seo; Lakdawala, Ness

    2013-01-01

    Highlights: • An innovative experimental set-up was designed and constructed for testing UV-PCO. • Test methodologies were developed to examine UV-PCO air cleaners for VOCs removal. • VOCs type, inlet concentration, flow rate, irradiance, and RH have influence on PCO. • Gas-phase ozonation with a variety of compounds was examined in a duct system. • Formation of by-products generated from incomplete conversion was investigated. -- Abstract: Photocatalytic oxidation (PCO) is a promising technology that has potential to be applied in mechanically ventilated buildings to improve indoor air quality (IAQ). However, the major research studies were done in bench-top scale reactors under ideal reaction conditions. In addition, no study has been carried out on the investigation of the ozonation and photolysis effect using a pilot duct system. The objective of this study is the development of methodologies to evaluate the performance of PCO systems. A systematic parametric evaluation of the effects of various kinetic parameters, such as compound's type, inlet concentration, airflow rate, light intensity, and relative humidity, was conducted, and new interpretations were provided from a fundamental analysis. In addition, the photolysis effect under vacuum ultraviolet (VUV) irradiation for a variety of volatile organic compounds (VOCs) was examined for the first time in a pilot duct system. The performance comparison of ultraviolet C (UVC)-PCO and VUV-PCO was also discussed due to the presence of ozone. Moreover, the formation of by-products generated with or without ozone generation was fully compared to evaluate the PCO technology

  6. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR

    International Nuclear Information System (INIS)

    Reid, Robert S.; Pearson, J. Bosie; Stewart, Eric T.

    2007-01-01

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.

  7. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    REID, ROBERT S. [Los Alamos National Laboratory; PEARSON, J. BOSIE [Los Alamos National Laboratory; STEWART, ERIC T. [Los Alamos National Laboratory

    2007-01-16

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.

  8. Experimental Evaluation of the Thermal Performance of a Water Shield for a Surface Power Reactor

    International Nuclear Information System (INIS)

    Pearson, J. Boise; Stewart, Eric T.; Reid, Robert S.

    2007-01-01

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 deg. C. The CFD model with 1/6-g predicts a maximum water temperature of 88 deg. C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield

  9. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  10. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  11. Experimental evaluation of thermal and energy performance of temperate green roofs: a case study in Beijing

    Science.gov (United States)

    Sun, T.; Institute of Hydrology; Water Resources

    2011-12-01

    An experimental evaluation of thermal and energy performance of temperate green roofs was carried out by thermal and meteorological observation and energy budget modeling using a setup of green roof in Beijing urban area. From both the yearly and daily temperature trends, the green roof could effectively damp down the undulation of roof surface temperature comparing with the conventional one. As an insulating screen, the green roof abated the amplitude of temperature by 9.0 in winter and 9.1 °C in summer, respectively. Under different cloud conditions, the green roof in summer time resulted in decreases in sensible heat and heat flux by 125.3W m-2 and 32.0 W m-2, respectively, on daily average comparing with the conventional one. Based on the energy budget analyses, under an assumptive scenario of 50% roof-greening in Beijing, a total of 34.1 PJ of sensible heat and 8.7 PJ of heat flux would be decreased for a summer period of 90 days. This study demonstrated that green roof, serving as an insulating screen to building top in comparison with the conventional roof, proved thermal improving effect in building scale and high energy saving potential for urban development.

  12. Experimental performance evaluation and validation of dynamical models of the Ocean Grazer

    NARCIS (Netherlands)

    van Rooij, Marijn; Meijer, Harmen; Prins, Wouter; Vakis, Antonis I.

    2015-01-01

    A functional scale prototype has been constructed for a single-piston pump (SPP) that will be used as a building block in the core technology of a novel wave energy converter termed the Ocean Grazer: the multi-pump, multi-piston power take-off (MP2PTO) system. Experimental measurements performed

  13. Experimentally Evaluated Explosion Resistance and Performance of Destruction Unit in Multiple Detonation of Ammunition

    Directory of Open Access Journals (Sweden)

    P. A. Baskakov

    2016-01-01

    Full Text Available The paper presents results of development and experimental investigation of explosion resistance and destruction unit performance in multiple detonation of ammunition with an explosive weight up to 0.7 kg of TNT. A preliminary evaluation of the explosion resistance was carried out using a model of explosion resistance localizer, represented as a thick-walled tube. As a result of explosive tests, the nature and characteristics of tube deformation under repeated explosions have been revealed. The findings allowed us to develop the first embodiment of the destruction unit with a turning non-separable heater and a two-layer localizer, which was heated by the induction field. The explosive life tests have revealed the following drawbacks: low resource localizer, jamming rotating mechanism in contact with the splinters, and impossible replacement of damaged localizer. In the second embodiment of the destruction unit a plate-assembled easychange localizer is mounted on the heater, and it is heated by heat transfer from the core. Tests have shown that, with such a placement, the uniform heating of the localizer is not reached. This leads to incomplete destruction of ammunition. Besides, because of the low strength of the pins connecting the plates, occurrs their rapid destruction. Taking into consideration the shortcomings of the previous two designs, the third option of the destruction unit with a replaceable localizer and induction heating of a localizer has been designed. A localizer material having high mechanical strength at high temperatures and good ferromagnetic properties has been selected. The paper offers an all-metal localizer design with the thickest wall at the bottom that is the most damageable. The paper has experimentally determined a critical deformation of the localizer when destroying the ammunition with varying weight of explosive and defined the heater and bump resource. As a result, the work proposes the destruction unit design

  14. An experimental evaluation on air purification performance of Clean-Air Heat Pump (CAHP) air cleaner

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Sun, Yuexia

    2018-01-01

    was 96.8%, which indicated that the most of gaseous pollutants were not accumulated in the CAHP. The regeneration temperature for the wheel could affect the air purification performance of CAHP. At 70 °C of regeneration temperature, the air-cleaning efficiency reached 96.7%. Up to 70% of the outdoor air......The escalation of energy consumption in buildings and heightened concerns about acceptable indoor air quality stimulate interest in the usage of air cleaner as an adjunct for indoor environmental conditioning. A regenerative desiccant wheel integrated into a ventilation system termed Clean-Air Heat...... Pump (CAHP) can improve the air quality during the process of dehumidification without using additional energy. An experimental study in a field lab was performed to investigate the air cleaning performance of CAHP. Photoacoustic gas analyzer-INNOVA was used to characterize chemical removal of indoor...

  15. Experimental evaluation of indoor magnetic distortion effects on gait analysis performed with wearable inertial sensors

    International Nuclear Information System (INIS)

    Palermo, E; Patanè, F; Cappa, P; Rossi, S

    2014-01-01

    Magnetic inertial measurement unit systems (MIMU) offer the potential to perform joint kinematics evaluation as an alternative to optoelectronic systems (OS). Several studies have reported the effect of indoor magnetic field disturbances on the MIMU's heading output, even though the overall effect on the evaluation of lower limb joint kinematics is not yet fully explored. The aim of the study is to assess the influence of indoor magnetic field distortion on gait analysis trials conducted with a commercial MIMU system. A healthy adult performed gait analysis sessions both indoors and outdoors. Data collected indoors were post-processed with and without a heading correction methodology performed with OS at the start of the gait trial. The performance of the MIMU system is characterized in terms of indices, based on the mean value of lower limb joint angles and the associated ROM, quantifying the system repeatability. We find that the effects of magnetic field distortion, such as the one we experienced in our lab, were limited to the transverse plane of each joint and to the frontal plane of the ankle. Sagittal plane values, instead, showed sufficient repeatability moving from outdoors to indoors. Our findings provide indications to clinicians on MIMU performance in the measurement of lower limb kinematics. (paper)

  16. Multidimensional evaluation of performance: experimental application of the balanced scorecard in Ferrara university hospital

    Directory of Open Access Journals (Sweden)

    Gregorio Pasquale

    2009-09-01

    Full Text Available Abstract Background and Aims One of the best-known performance planning and evaluation techniques utilising both monetary and non-monetary data is the Balanced Scorecard (BSC. This is a means of rationalising the global activity of a business in the attempt to create value, and to translate the company vision into a set of tactical objectives and measurable strategies. The aim of this study was to implement and evaluate the use of BSC in two departments of the St. Anna University Hospital, Ferrara: the Analysis Laboratory and Digestive Endoscopy operating units (OU. Materials and methods With the collaboration of the health workers involved, a precise methodological programme was pursued: Definition of the strategic map from 4 perspectives, according to Kaplan and Norton, Definition of the Key Performance Areas (KPA, or macro-objectives, Identification of the cause-effect relationships between KPAs, Identification of the sub-objectives of each KPA, Definition of the Key Performance Indicators (KPI, Definition of the weight/importance of each objective in the global evaluation. Results The information gathered permitted the definition of macro- and sub-objectives for each perspective, as well as determining the relevant indicators, standards, weights, frequency of detection and means of acquisition. Strategic maps showing the cause/effect relationships in each OU were created, as were 'evaluation panels', which describe the global performance of each department. For each perspective, the fundamental data were summarised in one table. Evaluation of each perspective yielded a positive result for the majority of the objectives, and the global result (including all 4 perspectives was found to be satisfactory. Discussion-Conclusion The Balanced Scorecard was implemented in the abovementioned OUs of St. Anna University Hospital, Ferrara, after the health workers themselves realised the need for change. In our research the employees were pleased to be

  17. Multidimensional evaluation of performance: experimental application of the balanced scorecard in Ferrara university hospital.

    Science.gov (United States)

    Verzola, Adriano; Bentivegna, Roberto; Carandina, Gianni; Trevisani, Lucio; Gregorio, Pasquale; Mandini, Alberto

    2009-09-08

    One of the best-known performance planning and evaluation techniques utilising both monetary and non-monetary data is the Balanced Scorecard (BSC). This is a means of rationalising the global activity of a business in the attempt to create value, and to translate the company vision into a set of tactical objectives and measurable strategies. The aim of this study was to implement and evaluate the use of BSC in two departments of the St. Anna University Hospital, Ferrara: the Analysis Laboratory and Digestive Endoscopy operating units (OU). With the collaboration of the health workers involved, a precise methodological programme was pursued: Definition of the strategic map from 4 perspectives, according to Kaplan and Norton, Definition of the Key Performance Areas (KPA), or macro-objectives, Identification of the cause-effect relationships between KPAs, Identification of the sub-objectives of each KPA, Definition of the Key Performance Indicators (KPI), Definition of the weight/importance of each objective in the global evaluation. The information gathered permitted the definition of macro- and sub-objectives for each perspective, as well as determining the relevant indicators, standards, weights, frequency of detection and means of acquisition. Strategic maps showing the cause/effect relationships in each OU were created, as were 'evaluation panels', which describe the global performance of each department. For each perspective, the fundamental data were summarised in one table. Evaluation of each perspective yielded a positive result for the majority of the objectives, and the global result (including all 4 perspectives) was found to be satisfactory. The Balanced Scorecard was implemented in the abovementioned OUs of St. Anna University Hospital, Ferrara, after the health workers themselves realised the need for change.In our research the employees were pleased to be evaluated, not only for the financial outcomes, but also for the satisfaction of improving

  18. Structural performance of an IP2 package in free drop test conditions: Numerical and experimental evaluations

    International Nuclear Information System (INIS)

    Lo Frano, Rosa; Pugliese, Giovanni; Nasta, Marco

    2014-01-01

    Highlights: • Vertical free drop test. • Qualification of an IP2 type Italian packaging. • Numerical and experimental investigation of the package integrity. • Demonstration the Italian packaging meets safety requirements. - Abstract: The casks or packaging systems used for the transportation of nuclear materials, especially spent fuel elements, have to be designed according to rigorous acceptance requirements, like the IAEA ones, in order to provide protection to human beings and environment against radiation exposure and contamination. This study deals with the free drop test of an Italian design packaging system to be used for the transportation of low and intermediate level radioactive wastes. Impact drop experiments were performed in the Lab. Scalbatraio of the DICI – University of Pisa. Dynamic analyses too have been carried out, by refined models of both the cask and target surface to predict the effects of the impact shock (vertical drop) on the package. The experimental tests and numerical analyses are thoroughly compared, presented and discussed. The numerical approach shows to be suitable to reproduce with good reliability the test situations and results

  19. Experimental Simulation-Based Performance Evaluation of an SMS-Based Emergency Geolocation Notification System

    Directory of Open Access Journals (Sweden)

    Isibor Osebor

    2017-01-01

    Full Text Available In an emergency, a prompt response can save the lives of victims. This statement generates an imperative issue in emergency medical services (EMS. Designing a system that brings simplicity in locating emergency scenes is a step towards improving response time. This paper therefore implemented and evaluated the performance of an SMS-based emergency geolocation notification system with emphasis on its SMS delivery time and the system’s geolocation and dispatch time. Using the RAS metrics recommended by IEEE for evaluation, the designed system was found to be efficient and effective as its reliability stood within 62.7% to 70.0% while its availability stood at 99% with a downtime of 3.65 days/year.

  20. Experimental Evaluation of a Low Emissions High Performance Duct Burner for Variable Cycle Engines (VCE)

    Science.gov (United States)

    Lohmann, R. P.; Mador, R. J.

    1979-01-01

    An evaluation was conducted with a three stage Vorbix duct burner to determine the performance and emissions characteristics of the concept and to refine the configuration to provide acceptable durability and operational characteristics for its use in the variable cycle engine (VCE) testbed program. The tests were conducted at representative takeoff, transonic climb, and supersonic cruise inlet conditions for the VSCE-502B study engine. The test stand, the emissions sampling and analysis equipment, and the supporting flow visualization rigs are described. The performance parameters including the fuel-air ratio, the combustion efficiency/exit temperature, thrust efficiency, and gaseous emissions calculations are defined. The test procedures are reviewed and the results are discussed.

  1. An Experimental Evaluation of the Performance of Two Combination Pitot Pressure Probes

    Science.gov (United States)

    Arend, David J.; Saunders, John D.

    2009-01-01

    Experimental tests have been completed which recorded the ability of two combination steady state and high response time varying Pitot probe designs to accurately measure steady stagnation pressure at a single location in a flow field. Tests were conducted of double-barreled and coannular Prati probes in a 3.5 in. diameter free jet probe calibration facility from Mach 0.1 to 0.9. Geometric symmetry and pitch (-40 deg to 40 deg) and yaw (0 deg to 40 deg) angle actuation were used to fully evaluate the probes. These tests revealed that the double-barreled configuration induced error in its steady state measurement at zero incidence that increased consistently with jet Mach number to 1.1 percent at Mach 0.9. For all Mach numbers, the double-barreled probe nulled at a pitch angle of approximately 7.0 deg and provided inconsistent measurements when yawed. The double-barreled probe provided adequate measurements via both its steady state and high response tubes (within +/- 0.15 percent accuracy) over unacceptable ranges of biased pitch and inconsistent yaw angles which varied with Mach number. By comparison, the coannular probe provided accurate measurements (at zero incidence) for all jet Mach numbers as well as over a flow angularity range which varied from +/- 26.0 deg at Mach 0.3 deg to +/- 14.0 deg at Mach 0.9. Based on these results, the Prati probe is established as the preferred design. Further experimental tests are recommended to document the frequency response characteristics of the Prati probe.

  2. Experimental evaluation of the influence of the team members' personalities on the team performance

    International Nuclear Information System (INIS)

    Nagasaka, Akihiko

    1998-01-01

    This report deals with the result of the experiment that testees' teams had coped with abnormal events on power plant simulator. 8 teams were AAA1, AAA2, ACD1, ACD2, CCC1, CCC2, DDD1 and DDD2 consist of 3 members. Members of teams were intentionally united by his personality with the results examined by Yatabe-Guilford personality test (A: Average type, C: Calm type, D: Director type). Each team coped with 8 abnormal events (leak from the pipe after the condensate booster pump-A and feedwater control system failure, vacuum pump-A failure, etc.). Teams' behaviors were evaluated and calculated the evaluated values about 3 team's functions: (1) direction and orientation (11 items), (2) recovery (13 items) and (3) maintenance of cooperation (13 items). The order of the evaluated values were almost AAAs≤ACDs≤CCCs< DDDs with each function. And the results on multiple comparison of the evaluated values are as follows: (a) There are remarkable significances between DDDs and other combinations of personalities (32 cases per 36 cases). (b) Some cases are significant among 2 teams of same combination of personalities (4 cases per 12 cases). Also the results on analysis of utterances of team member are as follows: (c) There is good correspondence of the number of utterances to the evaluated values. (d) With AAAs, the number of 'Instruction' is very small. (e) With CCCs, utterances related to maintenance of cooperation are relatively few. On these results, the author is convinced that combination of personalities in not matured team certainly relates team performance and utterances among the members. (author)

  3. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  4. Experimental evaluation of the performances of cellulosic pads made out of Kraft and NSSC corrugated papers as evaporative media

    International Nuclear Information System (INIS)

    Barzegar, Mahsa; Layeghi, Mohammad; Ebrahimi, Ghanbar; Hamzeh, Yahya; Khorasani, Manouchehr

    2012-01-01

    Highlights: ► We experimentally evaluated the performances of cellulosic pads. ► A number of experiments have been done in a wind tunnel. ► The results showed that cooling efficiency improves with decrease of air velocity and flute size. ► Water consumption increases with the increase of air velocity. ► Cooling efficiency of various pads was also compared. - Abstract: The purpose of this study was to evaluate the performances of cellulosic pads made out of Kraft and NSSC corrugated papers in three flute sizes, experimentally. A number of experiments have been done in a wind tunnel in order to evaluate the cooling efficiency and water consumption as a function of air velocity. The tests were carried out at three levels of air velocity (1.8, 2.25, and 2.67 ms −1 ) for three flute sizes of Kraft and NSSC corrugated papers (2.5, 3.5, and 4.5 mm). Analysis of the results indicated that cooling efficiency improves with decrease of air velocity and flute size of corrugated papers; however, water consumption increases with the increase of air velocity. The results were compared with each other and it was shown that the cellulosic pad made out of Kraft paper with 2.5 mm flute size has the highest performance (92%) at 1.8 ms −1 air velocity in comparison with the other cellulosic pads.

  5. Potential of Ventilation Radiators: Performance evaluation by numerical, analytical and experimental means

    Energy Technology Data Exchange (ETDEWEB)

    Myhren, Jonn Are

    2011-07-01

    give combined energy savings for heating and ventilation of 14-30 % in a system utilising a heat pump. - supply water temperatures as low as 35 deg. C could increase potential for utilising low temperature heat sources such as sun-, ground-, water- or waste-heat. This would be particularly relevant to new-built 'green' energy-efficient buildings, but several advantages may apply to retrofit applications as well. - Successful application of ventilation radiators requires understanding of relevant building factors, and the appropriate number, positioning and size of radiators for best effect. Evaluation studies must be made at the level of the building as a whole, not just for the heating-ventilation system. This work demonstrated that increased use of well-designed ventilation radiator arrangements can help to meet regulations issued in 2008 by the Swedish Dept. of Housing (Boverket BBR 16) and goals set in the Energy Performance of Buildings Directive (EPBD) in the same year

  6. Multidimensional evaluation of performance with experimental application of balanced scorecard: a two year experience

    Directory of Open Access Journals (Sweden)

    Antonioli Paola

    2011-05-01

    Full Text Available Abstract Background In today's dynamic health-care system, organizations such as hospitals are required to improve their performance for multiple stakeholders and deliver an integrated care that means to work effectively, be innovative and organize efficiently. Achieved goals and levels of quality can be successfully measured by a multidimensional approach like Balanced Scorecard (BSC. The aim of the study was to verify the opportunity to introduce BSC framework to measure performance in St. Anna University Hospital of Ferrara, applying it to the Clinical Laboratory Operative Unit in order to compare over time performance results and achievements of assigned targets. Methods In the first experience with BSC we distinguished four perspectives, according to Kaplan and Norton, identified Key Performance Areas and Key Performance Indicators, set standards and weights for each objective, collected data for all indicators, recognized cause-and-effect relationships in a strategic map. One year later we proceeded with the next data collection and analysed the preservation of framework aptitude to measure Operative Unit performance. In addition, we verified the ability to underline links between strategic actions belonging to different perspectives in producing outcomes changes. Results The BSC was found to be effective for underlining existing problems and identifying opportunities for improvements. The BSC also revealed the specific perspective contribution to overall performance enhancement. After time results comparison was possible depending on the selection of feasible and appropriate key performance indicators, which was occasionally limited by data collection problems. Conclusions The first use of BSC to compare performance at Operative Unit level, in course of time, suggested this framework can be successfully adopted for results measuring and revealing effective health factors, allowing health-care quality improvements.

  7. Multidimensional evaluation of performance with experimental application of balanced scorecard: a two year experience

    Science.gov (United States)

    2011-01-01

    Background In today's dynamic health-care system, organizations such as hospitals are required to improve their performance for multiple stakeholders and deliver an integrated care that means to work effectively, be innovative and organize efficiently. Achieved goals and levels of quality can be successfully measured by a multidimensional approach like Balanced Scorecard (BSC). The aim of the study was to verify the opportunity to introduce BSC framework to measure performance in St. Anna University Hospital of Ferrara, applying it to the Clinical Laboratory Operative Unit in order to compare over time performance results and achievements of assigned targets. Methods In the first experience with BSC we distinguished four perspectives, according to Kaplan and Norton, identified Key Performance Areas and Key Performance Indicators, set standards and weights for each objective, collected data for all indicators, recognized cause-and-effect relationships in a strategic map. One year later we proceeded with the next data collection and analysed the preservation of framework aptitude to measure Operative Unit performance. In addition, we verified the ability to underline links between strategic actions belonging to different perspectives in producing outcomes changes. Results The BSC was found to be effective for underlining existing problems and identifying opportunities for improvements. The BSC also revealed the specific perspective contribution to overall performance enhancement. After time results comparison was possible depending on the selection of feasible and appropriate key performance indicators, which was occasionally limited by data collection problems. Conclusions The first use of BSC to compare performance at Operative Unit level, in course of time, suggested this framework can be successfully adopted for results measuring and revealing effective health factors, allowing health-care quality improvements. PMID:21586111

  8. Multidimensional evaluation of performance with experimental application of balanced scorecard: a two year experience.

    Science.gov (United States)

    Lupi, Silvia; Verzola, Adriano; Carandina, Gianni; Salani, Manuela; Antonioli, Paola; Gregorio, Pasquale

    2011-05-17

    In today's dynamic health-care system, organizations such as hospitals are required to improve their performance for multiple stakeholders and deliver an integrated care that means to work effectively, be innovative and organize efficiently. Achieved goals and levels of quality can be successfully measured by a multidimensional approach like Balanced Scorecard (BSC). The aim of the study was to verify the opportunity to introduce BSC framework to measure performance in St. Anna University Hospital of Ferrara, applying it to the Clinical Laboratory Operative Unit in order to compare over time performance results and achievements of assigned targets. In the first experience with BSC we distinguished four perspectives, according to Kaplan and Norton, identified Key Performance Areas and Key Performance Indicators, set standards and weights for each objective, collected data for all indicators, recognized cause-and-effect relationships in a strategic map. One year later we proceeded with the next data collection and analysed the preservation of framework aptitude to measure Operative Unit performance. In addition, we verified the ability to underline links between strategic actions belonging to different perspectives in producing outcomes changes. The BSC was found to be effective for underlining existing problems and identifying opportunities for improvements. The BSC also revealed the specific perspective contribution to overall performance enhancement. After time results comparison was possible depending on the selection of feasible and appropriate key performance indicators, which was occasionally limited by data collection problems. The first use of BSC to compare performance at Operative Unit level, in course of time, suggested this framework can be successfully adopted for results measuring and revealing effective health factors, allowing health-care quality improvements.

  9. Development and performance evaluation of an experimental fine pitch detector multislice CT scanner.

    Science.gov (United States)

    Imai, Yasuhiro; Nukui, Masatake; Ishihara, Yotaro; Fujishige, Takashi; Ogata, Kentaro; Moritake, Masahiro; Kurochi, Haruo; Ogata, Tsuyoshi; Yahata, Mitsuru; Tang, Xiangyang

    2009-04-01

    The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction) x 32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI(vol) of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

  10. Experimental Performance Evaluation of a Supersonic Turbine for Rocket Engine Applications

    Science.gov (United States)

    Snellgrove, Lauren M.; Griffin, Lisa W.; Sieja, James P.; Huber, Frank W.

    2003-01-01

    In order to mitigate the risk of rocket propulsion development, efficient, accurate, detailed fluid dynamics analysis and testing of the turbomachinery is necessary. To support this requirement, a task was developed at NASA Marshall Space Flight Center (MSFC) to improve turbine aerodynamic performance through the application of advanced design and analysis tools. These tools were applied to optimize a supersonic turbine design suitable for a reusable launch vehicle (RLV). The hot gas path and blading were redesigned-to obtain an increased efficiency. The goal of the demonstration was to increase the total-to- static efficiency of the turbine by eight points over the baseline design. A sub-scale, cold flow test article modeling the final optimized turbine was designed, manufactured, and tested in air at MSFC s Turbine Airflow Facility. Extensive on- and off- design point performance data, steady-state data, and unsteady blade loading data were collected during testing.

  11. Experimental evaluation of the influence of various rests on task performance

    International Nuclear Information System (INIS)

    Nagasaka, Akihiko; Hirose, Ayako

    2000-01-01

    This report deals with the result of the experiment that 8 subjects had executed adding task and search task. They executed each task in 80 minutes under 5 conditions: (1) with no rest, and with 4 kinds of 20 minutes rests, in which they (2) opened eyes, (3) closed eyes, (4) closed eyes with listening classic music and (5) closed eyes with feet massage, in the middle of the task. The results of analysis of variance with the task performance in the latter half, there were significant differences between each condition with every subject in adding task, and with 6 subjects in search task. However, the orders of the task performance with each condition were not the same by each subject. It was suggested that transition of the arousal levels under the rest was related to the effects of the rest rather than the subjects' taste in rests. In the rest, the percentage of α wave of electroencephalogram and the coefficient of variation of R-R interval (time interval of heart beats) were increased than in executing task. The mean Kendall's rank correlation of coefficient with the order of increase rate of α/β wave and the task performance in the latter half was slightly negative in adding task, but was about 0.4 in search task. From these results, about six requirements for 'an effective rest' were able to be mentioned, for example, 'the devices that raises the arousal levels is carried out just before a rest end'. (author)

  12. An experimental evaluation of joint electrical resistance on power lead thermal performance

    International Nuclear Information System (INIS)

    Datskov, V.I.; Demko, J.A.; Augustynowicz, S.D.; Hutton, R.D.

    1994-01-01

    The amount of electrical resistance in braze joints is not known for certain. In addition the annealing processes that occurs during a braze or solder operation can change the residual resistivity ratio (RRR) of the copper. The change in the electrical resistivity of samples of copper because of exposure to conditions that a high current lead would see during a brazing operation were experimentally investigated. A sample was taken from a manufacturing and brazing trial of the high current power leads for the Superconducting Super Collider (SSC), and from oxygen free high conductivity copper (OFHC) 101 rod similar to that used in the trial. The samples were heated under conditions that a current lead would undergo during the brazing process. Measurements were made of the electrical resistance of the copper specimens and across a braze joint in the manufacturing trial sample for temperatures ranging from liquid helium to room temperature. A prototype of the SSC high current lead is shown. This lead was fabricated from 5 sections that were brazed together. Some results for the measured residual resistivity ratio (RRR) along this lead are given

  13. Experimental evaluation of the influence of various rests on task performance

    Energy Technology Data Exchange (ETDEWEB)

    Nagasaka, Akihiko; Hirose, Ayako [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

    2000-01-01

    This report deals with the result of the experiment that 8 subjects had executed adding task and search task. They executed each task in 80 minutes under 5 conditions: (1) with no rest, and with 4 kinds of 20 minutes rests, in which they (2) opened eyes, (3) closed eyes, (4) closed eyes with listening classic music and (5) closed eyes with feet massage, in the middle of the task. The results of analysis of variance with the task performance in the latter half, there were significant differences between each condition with every subject in adding task, and with 6 subjects in search task. However, the orders of the task performance with each condition were not the same by each subject. It was suggested that transition of the arousal levels under the rest was related to the effects of the rest rather than the subjects' taste in rests. In the rest, the percentage of {alpha} wave of electroencephalogram and the coefficient of variation of R-R interval (time interval of heart beats) were increased than in executing task. The mean Kendall's rank correlation of coefficient with the order of increase rate of {alpha}/{beta} wave and the task performance in the latter half was slightly negative in adding task, but was about 0.4 in search task. From these results, about six requirements for 'an effective rest' were able to be mentioned, for example, 'the devices that raises the arousal levels is carried out just before a rest end'. (author)

  14. Experimental evaluation of C.I. engine performance using diesel blended with Jatropha biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sunil [Mechanical Department, R. G. P. V. Bhopal (M.P.) (India); Chaube, Alok [Mechanical Department, Jabalpur Engineering College Jabalpur (M.P.) (India); Jain, Shashi Kumar [School of Energy and Environment Management, R.G.P.V. Bhopal (India)

    2012-07-01

    Costlier and depleting fossil fuels are prompting researchers to use edible as well as non-edible vegetable oils as promising alternative to petro-diesel. The higher viscosity of vegetable oils leads to problem in pumping, atomization and spray characteristics. The improper mixing of vegetable oils with air leads to incomplete combustion. The best way to use vegetable oils as fuel in compression ignition (CI) engines is to convert it into biodiesel. Biodiesel is a methyl or ethyl ester of fatty acids made from vegetable oils (both edible and non-edible) and animal fat. The main feedstock for biodiesel production can be non-edible oil obtained from Jatropha curcas plant. Jatropha curcas plant can be cultivated on different terrains in India under extreme climatic conditions. Biodiesel can be used in its pure form or as a blend with petro-diesel in different proportions. It is being used in CI engines because it has properties similar to petro-diesel. The aim of this paper is to analyze suitability of petro-diesel blended with biodiesel in varying proportions in CI engines. For this purpose, a stationary single-cylinder four-stroke CI engine was tested with diesel blended with Jatropha biodiesel in 0%, 5%, 20%, 50%, 80% and 100%. Comparative measures of specific fuel consumption (SFC), brake thermal efficiency, smoke opacity, HC, CO2, CO, O2, NOX have been presented and discussed. Engine performance in terms of comparable brake thermal efficiency and SFC with lower emissions (HC, CO2, CO) was observed with B20 fuel compared to petro-diesel. Volumetric efficiency showed almost no variation for all the blends. Important observations related to noise and vibrations during testing have also been discussed.

  15. Analytical and Experimental Performance Evaluation of BLE Neighbor Discovery Process Including Non-Idealities of Real Chipsets

    Directory of Open Access Journals (Sweden)

    David Perez-Diaz de Cerio

    2017-03-01

    Full Text Available The purpose of this paper is to evaluate from a real perspective the performance of Bluetooth Low Energy (BLE as a technology that enables fast and reliable discovery of a large number of users/devices in a short period of time. The BLE standard specifies a wide range of configurable parameter values that determine the discovery process and need to be set according to the particular application requirements. Many previous works have been addressed to investigate the discovery process through analytical and simulation models, according to the ideal specification of the standard. However, measurements show that additional scanning gaps appear in the scanning process, which reduce the discovery capabilities. These gaps have been identified in all of the analyzed devices and respond to both regular patterns and variable events associated with the decoding process. We have demonstrated that these non-idealities, which are not taken into account in other studies, have a severe impact on the discovery process performance. Extensive performance evaluation for a varying number of devices and feasible parameter combinations has been done by comparing simulations and experimental measurements. This work also includes a simple mathematical model that closely matches both the standard implementation and the different chipset peculiarities for any possible parameter value specified in the standard and for any number of simultaneous advertising devices under scanner coverage.

  16. Making comparative performance information more comprehensible: an experimental evaluation of the impact of formats on consumer understanding.

    Science.gov (United States)

    Damman, Olga C; De Jong, Anco; Hibbard, Judith H; Timmermans, Danielle R M

    2016-11-01

    We aimed to investigate how different presentation formats influence comprehension and use of comparative performance information (CPI) among consumers. An experimental between-subjects and within-subjects design with manipulations of CPI presentation formats. We enrolled both consumers with lower socioeconomic status (SES)/cognitive skills and consumers with higher SES/cognitive skills, recruited through an online access panel. Respondents received fictitious CPI and completed questions about interpretation and information use. Between subjects, we tested (1) displaying an overall performance score (yes/no); (2) displaying a small number of quality indicators (5 vs 9); and (3) displaying different types of evaluative symbols (star ratings, coloured dots and word icons vs numbers and bar graphs). Within subjects, we tested the effect of a reduced number of healthcare providers (5 vs 20). Data were analysed using descriptive analysis, analyses of variance and paired-sampled t tests. A total of 902 (43%) respondents participated. Displaying an overall performance score and the use of coloured dots and word icons particularly enhanced consumer understanding. Importantly, respondents provided with coloured dots most often correctly selected the top three healthcare providers (84.3%), compared with word icons (76.6% correct), star ratings (70.6% correct), numbers (62.0%) and bars (54.2%) when viewing performance scores of 20 providers. Furthermore, a reduced number of healthcare providers appeared to support consumers, for example, when provided with 20 providers, 69.5% correctly selected the top three, compared with 80.2% with five providers. Particular presentation formats enhanced consumer understanding of CPI, most importantly the use of overall performance scores, word icons and coloured dots, and a reduced number of providers displayed. Public report efforts should use these formats to maximise impact on consumers. Published by the BMJ Publishing Group Limited

  17. Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

    Science.gov (United States)

    Nagorny, Aleksandr S.; Jansen, Ralph H.; Kankam, M. David

    2007-01-01

    This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

  18. Experimental performance evaluation of solid concrete and dry insulation materials for passive buildings in hot and humid climatic conditions

    International Nuclear Information System (INIS)

    Rehman, Hassam Ur

    2017-01-01

    Highlights: • Experimental investigation of building insulation materials in UAE from 2012–2014. • Four same calorimeters with different south walls were built in open air laboratory. • Heat flux was reduced by 22–75% in steady state analysis during summer by insulation. • Hence, energy consumption for cooling was reduced by an average 7.6–25.3%. • Heat flow was steady in free floating analysis in winter through insulated walls. - Abstract: It is known that enhancement of building energy efficiency can help in reducing energy consumption. The use of the solar insulating materials are the most efficient and cost effective passive methods for reducing the cooling requirements of the buildings. Apart from theoretical studies, no detailed experimental studies were performed in the UAE on energy savings by using solar insulation materials on buildings. Four (3 m × 3 m × 3 m) solar calorimeters were built in RAK, UAE in order to perform an open air outdoor test for energy savings obtained with solar insulating materials. The design is aimed to determine the heat flux reduction and the energy savings achieved with and without different solar insulating materials, mounted at the south wall of solar calorimeters with similar indoor and ambient conditions. Experimental results are discussed to evaluate the thermal performance during high temperature conditions in summer’s period when cooling demand of the building is at its peak and also in winters when there is no cooling demand. The test is from 2012 to 2014. The controlled-temperature experimental study at a set point of 24 °C showed that if the standard building material, i.e. solid concrete, is retrofitted with polyisocyanurate (PIR) and reflective coatings or completely replaced with energy-efficient dry insulation material walls such as exterior insulation finishing system (EIFS), energy savings up to an average of 7.6–25.3% can be achieved. This is due to the reduction of heat flux by an

  19. Experimental performance evaluation of software defined networking (SDN) based data communication networks for large scale flexi-grid optical networks.

    Science.gov (United States)

    Zhao, Yongli; He, Ruiying; Chen, Haoran; Zhang, Jie; Ji, Yuefeng; Zheng, Haomian; Lin, Yi; Wang, Xinbo

    2014-04-21

    Software defined networking (SDN) has become the focus in the current information and communication technology area because of its flexibility and programmability. It has been introduced into various network scenarios, such as datacenter networks, carrier networks, and wireless networks. Optical transport network is also regarded as an important application scenario for SDN, which is adopted as the enabling technology of data communication networks (DCN) instead of general multi-protocol label switching (GMPLS). However, the practical performance of SDN based DCN for large scale optical networks, which is very important for the technology selection in the future optical network deployment, has not been evaluated up to now. In this paper we have built a large scale flexi-grid optical network testbed with 1000 virtual optical transport nodes to evaluate the performance of SDN based DCN, including network scalability, DCN bandwidth limitation, and restoration time. A series of network performance parameters including blocking probability, bandwidth utilization, average lightpath provisioning time, and failure restoration time have been demonstrated under various network environments, such as with different traffic loads and different DCN bandwidths. The demonstration in this work can be taken as a proof for the future network deployment.

  20. Experimental Evaluation of Performance of Constant Power Prime-Mover Driven Isolated 3-φ SEIG for Pico-Hydro Power Generation System in Remote Mountainous Region of Himalayas

    Directory of Open Access Journals (Sweden)

    Rathore Umesh C.

    2016-01-01

    Full Text Available This paper presents the experimental evaluation of the performance of 3-φ self-excited induction generator (SEIG suitable for pico-hydro power generation system feeding domestic load in remote mountainous region. The use of induction generators is most suitable for renewable energy conversion systems due to their enormous advantages over conventional synchronous generators. Important features of induction generators include the simplicity in construction, ruggedness, simplified control, ease in maintenance and small size per generated kW. The performance characteristics of 3-φ SEIG feeding isolated load are evaluated using MATLAB-Simulink model based on the prevalent renewable energy sources inputs and loading conditions in mountainous terrain of Himalayas. The results are validated using an experimental set-up comprising of 3-φ, 3 HP induction motor run as 3- φ induction generator driven by 5HP, 4-pole DC shunt motor acting as prime-mover.

  1. NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Apte, Michael G.; Black, Douglas R.; Hotchi, Toshifumi; Lucas, Donald; Lunden, Melissa M.; Mirer, Anna G.; Spears, Michael; Sullivan, Douglas P.

    2009-12-01

    The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.

  2. Agronomic performance of new open pollinated experimental lines of broccoli (Brassica oleracea L. var. italica evaluated under organic farming.

    Directory of Open Access Journals (Sweden)

    Samira Sahamishirazi

    Full Text Available In order to develop new open pollinating cultivars of broccoli for organic farming, two experiments were conducted during fall 2015 and spring 2016. This study was aimed at comparing the agronomic performance of eleven new open pollinating breeding lines of broccoli to introduce new lines and to test their seasonal suitability for organic farming. Field experiments were carried out at the organic research station Kleinhohenheim of the University of Hohenheim (Stuttgart-Germany. Different agronomic traits total biomass fresh weight, head fresh weight, head diameter, hollow-stem, fresh weight harvest index and marketable yield were assessed together with commercial control cultivars. The data from both experiments were analyzed using a two-stage mixed model approach. In our study, genotype, growing season and their interaction had significant effects on most traits. Plants belonging to the fall growing season had bigger sizes in comparison to spring with significantly (p< 0.0001 higher biomass fresh weight. Some experimental lines had significant lower head fresh weight in spring in comparison to the fall season. The high temperature during the harvest period for the spring season affected the yield negatively through decreasing the firmness of broccoli heads. The low average minimum temperatures during the spring growing season lead to low biomass fresh weight but high fresh weight harvest index. Testing the seasonal suitability of all open pollinating lines showed that the considered fall season was better for broccoli production. However, the change in yield between the fall and the spring growing season was not significant for "Line 701" and "CHE-MIC". Considering the expression of different agronomic traits, "CHE-GRE-G", "Calinaro" and "CAN-SPB" performed the best in the fall growing season, and "CHE-GRE-G", "CHE-GRE-A", "CHE-BAL-A" and "CHE-MIC" and "Line 701" were best in the spring growing season, specifically due to the highest marketable

  3. Experimental demonstration of radiation effects on the performance of a stirling-alternator convertor and candidate materials evaluation

    Science.gov (United States)

    Mireles, Omar R.

    Free-piston Stirling power convertors are under consideration by NASA for service in the Advanced Stirling Radioisotope Generator (ASRG) and Fission Surface Power (FSP) systems to enable aggressive exploration missions by providing a reliable and constant power supply. The ASRG must withstand environmental radiation conditions, while the FSP system must tolerate a mixed neutron and gamma-ray environment resulting from self-irradiation. Stirling-alternators utilize rare earth magnets and a variety of organic materials whose radiation limits dominate service life estimates and shielding requirements. The project objective was to demonstrate the performance of the alternator, identify materials that exhibit excessive radiation sensitivity, identify radiation tolerant substitutes, establish empirical dose limits, and demonstrate the feasibility of cost effective nuclear and radiation tests by selection of the appropriate personnel and test facilities as a function of hardware maturity. The Stirling Alternator Radiation Test Article (SARTA) was constructed from linear alternator components of a Stirling convertor and underwent significant pre-exposure characterization. The SARTA was operated at the Sandia National Laboratories Gamma Irradiation Facility to a dose of over 40 Mrad. Operating performance was within nominal variation, although modestly decreasing trends occurred in later runs as well as the detection of an electrical fault after the final exposure. Post-irradiation disassembly and internal inspection revealed minimal degradation of the majority of the organic components. Radiation testing of organic material coupons was conducted since the majority of the literature was inconsistent. These inconsistencies can be attributed to testing at environmental conditions vastly different than those Stirling-alternator organics will experience during operation. Samples were irradiated at the Texas A&M TRIGA reactor to above expected FSP neutron fluence. A thorough

  4. Experimental investigation and performance evaluation of DI diesel engine fueled by waste oil-diesel mixture in emulsion with water

    Directory of Open Access Journals (Sweden)

    Nanthagopal Kasianantham

    2009-01-01

    Full Text Available Exploitation of the natural reserves of petroleum products has put a tremendous onus on the automotive industry. Increasing pollution levels and the depletion of the petroleum reserves have lead to the search for alternate fuel sources for internal combustion engines. Usage of vegetable oils poses some challenges like poor spray penetration, valve sticking and clogging of injector nozzles. Most of these problems may be solved by partial substitution of diesel with vegetable oil. In this work, the performance and emission characteristics of a direct injection diesel engine fueled by waste cooking oil-diesel emulsion with different water contents are evaluated. The use of waste cooking oil-diesel emulsion lowers the peak temperature, which reduces the formation of NOx. Moreover the phenomenon of micro explosion that results during the combustion of an emulsified fuel finely atomizes the fuel droplets and thus enhances combustion. Experiments show that CO concentration is reduced as the water content is increased and it is seen that 20% water content gives optimum results. Also, there is a significant reduction in NOx emissions.

  5. Performance evaluation of two solar stills of different geometries: Tubular versus triangular: Experimental study, numerical simulation, and second law analysis

    DEFF Research Database (Denmark)

    Rahbar, Nader; Asadi, Amin; Fotouhi-Bafghi, Ehsan

    2018-01-01

    In this study, two types of solar stills, triangular and tubular one, have been experimentally tested under a real weather condition. Following the same procedure, the experiments were carried out over seven typical winter days and the effects of solar radiation and ambient temperature on water...... are the main reasons to have a better water production in the tubular still. Furthermore, the cost of water production by the triangular solar still was found to be lower due to its lower manufacturing cost compare to that of tubular one. Based on the experimental results, two new correlations have been...... productivity and total efficiency of the stills has been experimentally investigated. Furthuremore, to understand the detail structures of the air flow inside the enclosures, the fluid flow has been numerically simulated using computational fluid dynamics. Having the details of the fluid flow, the values...

  6. Experimental evaluations of wearable ECG monitor.

    Science.gov (United States)

    Ha, Kiryong; Kim, Youngsung; Jung, Junyoung; Lee, Jeunwoo

    2008-01-01

    Healthcare industry is changing with ubiquitous computing environment and wearable ECG measurement is one of the most popular approaches in this healthcare industry. Reliability and performance of healthcare device is fundamental issue for widespread adoptions, and interdisciplinary perspectives of wearable ECG monitor make this more difficult. In this paper, we propose evaluation criteria considering characteristic of both ECG measurement and ubiquitous computing. With our wearable ECG monitors, various levels of experimental analysis are performed based on evaluation strategy.

  7. Agronomic performance of new open pollinated experimental lines of broccoli (Brassica oleracea L. var. italica) evaluated under organic farming.

    Science.gov (United States)

    Sahamishirazi, Samira; Moehring, Jens; Zikeli, Sabine; Fleck, Michael; Claupein, Wilhelm; Graeff-Hoenninger, Simone

    2018-01-01

    In order to develop new open pollinating cultivars of broccoli for organic farming, two experiments were conducted during fall 2015 and spring 2016. This study was aimed at comparing the agronomic performance of eleven new open pollinating breeding lines of broccoli to introduce new lines and to test their seasonal suitability for organic farming. Field experiments were carried out at the organic research station Kleinhohenheim of the University of Hohenheim (Stuttgart-Germany). Different agronomic traits total biomass fresh weight, head fresh weight, head diameter, hollow-stem, fresh weight harvest index and marketable yield were assessed together with commercial control cultivars. The data from both experiments were analyzed using a two-stage mixed model approach. In our study, genotype, growing season and their interaction had significant effects on most traits. Plants belonging to the fall growing season had bigger sizes in comparison to spring with significantly (pbroccoli heads. The low average minimum temperatures during the spring growing season lead to low biomass fresh weight but high fresh weight harvest index. Testing the seasonal suitability of all open pollinating lines showed that the considered fall season was better for broccoli production. However, the change in yield between the fall and the spring growing season was not significant for "Line 701" and "CHE-MIC". Considering the expression of different agronomic traits, "CHE-GRE-G", "Calinaro" and "CAN-SPB" performed the best in the fall growing season, and "CHE-GRE-G", "CHE-GRE-A", "CHE-BAL-A" and "CHE-MIC" and "Line 701" were best in the spring growing season, specifically due to the highest marketable yield and proportion of marketable heads.

  8. Experimental evaluation of the performance and emissions of diesel engines using blends of crude castor oil and diesel; Avaliacao experimental do desempenho e emissoes de motores diesel usando misturas de oleo de mamona e oleo diesel

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel, Valeria Said de Barros; Pereira, Pedro Paulo [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica; Belchior, Carlos Rodrigues Pereira [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Oceanica

    2004-07-01

    This work refers to the experimental evaluation of diesel generators operating with blend of crude castor oil and diesel. Performance and emissions tests were accomplished in a diesel engine of direct injection. Because of the high viscosity of the blend a device was installed on the engine in order to lower the blend viscosity. A comprehensive analysis of the results obtained in these tests indicates the possibility of use of the blend of castor oil and diesel as fuel for diesel-generators, with modifications introduced in the engines. (author)

  9. Experimental evaluation of earthquake induced relay chattering

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.; Shteyngart, S.

    1990-01-01

    An experimental evaluation of relay performance under vibratory environments is discussed in this paper. Single frequency excitation was used for most tests. Limited tests were performed with random multifrequency inputs. The capacity of each relay was established based on a two-millisecond chatter criterion. The experimental techniques are described and the effects of parameters in controlling the relay capacity levels are illustrated with test data. A wide variation of the capacity levels was observed due to the influence of parameters related to the design of the relay and nature of the input motion. 3 refs., 15 figs

  10. Experimental Evaluation for the Microvibration Performance of a Segmented PC Method Based High Technology Industrial Facility Using 1/2 Scale Test Models

    Directory of Open Access Journals (Sweden)

    Sijun Kim

    2017-01-01

    Full Text Available The precast concrete (PC method used in the construction process of high technology industrial facilities is limited when applied to those with greater span lengths, due to the transport length restriction (maximum length of 15~16 m in Korea set by traffic laws. In order to resolve this, this study introduces a structural system with a segmented PC system, and a 1/2 scale model with a width of 9000 mm (hereafter Segmented Model is manufactured to evaluate vibration performance. Since a real vibrational environment cannot be reproduced for vibration testing using a scale model, a comparative analysis of their relative performances is conducted in this study. For this purpose, a 1/2 scale model with a width of 7200 mm (hereafter Nonsegmented Model of a high technology industrial facility is additionally prepared using the conventional PC method. By applying the same experiment method for both scale models and comparing the results, the relative vibration performance of the Segmented Model is observed. Through impact testing, the natural frequencies of the two scale models are compared. Also, in order to analyze the estimated response induced by the equipment, the vibration responses due to the exciter are compared. The experimental results show that the Segmented Model exhibits similar or superior performances when compared to the Nonsegmented Model.

  11. Experimental evaluation of cell liners

    International Nuclear Information System (INIS)

    Wierman, R.W.; Simmons, L.D.; Muhlestein, L.D.

    Cell liners may be used in breeder reactor sodium pipe ways, sodium cells, and lower cavity region to provide a leak-tight cell and to protect the concrete from sodium in the unlikely event of a sodium spill. The objectives of the HEDL liner verification test program are to evaluate the integrity of liner concepts under postulated accident conditions and to develop the experimental data base which will demonstrate that liners will not fail. Two specific tests are reported; a high temperature liner feature test, and a large-scale liner sodium spill test. In both tests no failures of the liners or tendencies toward failure were detected. The discussed liner designs appeared to be conservative, and the liner strength appeared to be more than adequate

  12. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  13. Effects of a performance and quality improvement intervention on the work environment in HIV-related care: a quasi-experimental evaluation in Zambia.

    Science.gov (United States)

    Bazant, Eva; Sarkar, Supriya; Banda, Joseph; Kanjipite, Webby; Reinhardt, Stephanie; Shasulwe, Hildah; Mulilo, Joyce Monica Chongo; Kim, Young Mi

    2014-12-20

    Human resource shortages and reforms in HIV-related care make it challenging for frontline health care providers in southern Africa to deliver high-quality services. At health facilities of the Zambian Defence Forces, a performance and quality improvement approach was implemented to improve HIV-related care and was evaluated in 2010/2011. Changes in providers' work environment and perceived quality of HIV-related care were assessed to complement data of provider performance. The intervention involved on-site training, supportive supervision, and action planning focusing on detailed service delivery standards. The quasi-experimental evaluation collected pre- and post-intervention data from eight intervention and comparison facilities matched on defence force branch and baseline client volume. Overall, 101 providers responded to a 24-item questionnaire on the work environment, covering topics of drugs, supplies, and equipment; training, feedback, and supervision; compensation; staffing; safety; fulfilment; and HIV services quality. In bivariate analysis and multivariate analyses, we assessed changes within each study group and between the two groups. In the bivariate analysis, the intervention group providers reported improvements in the work environment on adequacy of equipment, feeling safe from harm, confidence in clinical skills, and reduced isolation, while the comparison group reported worsening of the work environment on supplies, training, safety, and departmental morale.In the multivariate analysis, the intervention group's improvement and the comparison group's decline were significant on perceived adequacy of drugs, supplies, and equipment; constructive feedback received from supervisor and co-workers; and feeling safe from physical harm (all P equipment). Further, the item "provider lacks confidence in some clinical skills" declined in the intervention group but increased in the comparison group (P = -0.005). In multivariate analysis, changes in perceived

  14. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  15. Supercapacitors Performance Evaluation

    OpenAIRE

    Zhang, S; Pan, N

    2015-01-01

    The performance of a supercapacitor can be characterized by a series of key parameters, including the cell capacitance, operating voltage, equivalent series resistance, power density, energy density, and time constant. To accurately measure these parameters, a variety of methods have been proposed and are used in academia and industry. As a result, some confusion has been caused due to the inconsistencies between different evaluation methods and practices. Such confusion hinders effective com...

  16. Experimental evaluation of Arabic OCR systems

    Directory of Open Access Journals (Sweden)

    Mansoor Alghamdi

    2017-11-01

    Full Text Available Purpose – The aim of this paper is to experimentally evaluate the effectiveness of the state-of-the-art printed Arabic text recognition systems to determine open areas for future improvements. In addition, this paper proposes a standard protocol with a set of metrics for measuring the effectiveness of Arabic optical character recognition (OCR systems to assist researchers in comparing different Arabic OCR approaches. Design/methodology/approach – This paper describes an experiment to automatically evaluate four well-known Arabic OCR systems using a set of performance metrics. The evaluation experiment is conducted on a publicly available printed Arabic dataset comprising 240 text images with a variety of resolution levels, font types, font styles and font sizes. Findings – The experimental results show that the field of character recognition for printed Arabic still requires further research to reach an efficient text recognition method for Arabic script. Originality/value – To the best of the authors’ knowledge, this is the first work that provides a comprehensive automated evaluation of Arabic OCR systems with respect to the characteristics of Arabic script and, in addition, proposes an evaluation methodology that can be used as a benchmark by researchers and therefore will contribute significantly to the enhancement of the field of Arabic script recognition.

  17. Experimental investigation of n-butanol/diesel fuel blends and n-butanol fumigation – Evaluation of engine performance, exhaust emissions, heat release and flammability analysis

    International Nuclear Information System (INIS)

    Şahin, Zehra; Durgun, Orhan; Aksu, Orhan N.

    2015-01-01

    Highlights: • n-Butanol/diesel fuel blends and n-butanol fumigation investigated experimentally. • Flammability analysis of n-butanol performed. • Smoke decreases significantly for n-butanol/diesel fuel blends and n-butanol fumigation. • HC emission increases significantly for n-butanol/diesel fuel blends and n-butanol fumigation. • 2% n-Butanol/diesel fuel blend decreases slightly BSFC. - Abstract: The aim of this paper is to investigate and compare the effects of n-butanol/diesel fuel blends (nBDFBs) and n-butanol fumigation (nBF) on the engine performance and exhaust emissions in a turbocharged automobile diesel engine. Also, evaluations based on heat release and flammability analysis have been done. Experiments have been performed for various n-nBDFBs and nBF at different engine speeds and loads. For nBDFBs and nBF tests; nB2, nB4 and nB6 and nBF2, nBF4 and nBF6n-butanol percentages were selected. Here, for example nB2 and nBF2 contains 2% n-butanol and 98% diesel fuel by volume respectively. The test results showed that smoke decreases significantly by applying both of these two methods. However, decrement ratios of smoke for fumigation method are higher than that of blend method. NO x emission decreases for nB2, but it increases for nB4 and nB6 at selected engine speeds and loads. NO x emission decreases generally for nBF. For nB2 and nB4, BSFC decreases slightly but it increases for nB6. For nBF, BSFC increases at all of the test conditions. Adding n-butanol to diesel fuel becomes expensive for two methods. For nBDFBs, heat release rate (HRR) diagrams exhibit similar typical characteristic to NDF. However, for nBF, HRR shows slightly different pattern from NDF and a double peak is observed in the HRR diagram. The first peak occurs earlier than NDF and the second peak takes places later. In addition, this diagram shows that the first peak becomes larger and the second peak diminishes as n-butanol ratio is increased. Because of pilot injection of

  18. Criteria for performance evaluation

    Directory of Open Access Journals (Sweden)

    David J. Weiss

    2009-03-01

    Full Text Available Using a cognitive task (mental calculation and a perceptual-motor task (stylized golf putting, we examined differential proficiency using the CWS index and several other quantitative measures of performance. The CWS index (Weiss and Shanteau, 2003 is a coherence criterion that looks only at internal properties of the data without incorporating an external standard. In Experiment 1, college students (n = 20 carried out 2- and 3-digit addition and multiplication problems under time pressure. In Experiment 2, experienced golfers (n = 12, also college students, putted toward a target from nine different locations. Within each experiment, we analyzed the same responses using different methods. For the arithmetic tasks, accuracy information (mean absolute deviation from the correct answer, MAD using a coherence criterion was available; for golf, accuracy information using a correspondence criterion (mean deviation from the target, also MAD was available. We ranked the performances of the participants according to each measure, then compared the orders using Spearman's rextsubscript{s}. For mental calculation, the CWS order correlated moderately (rextsubscript{s} =.46 with that of MAD. However, a different coherence criterion, degree of model fit, did not correlate with either CWS or accuracy. For putting, the ranking generated by CWS correlated .68 with that generated by MAD. Consensual answers were also available for both experiments, and the rankings they generated correlated highly with those of MAD. The coherence vs. correspondence distinction did not map well onto criteria for performance evaluation.

  19. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  20. Covariance data evaluation for experimental data

    International Nuclear Information System (INIS)

    Liu Tingjin

    1993-01-01

    Some methods and codes have been developed and utilized for covariance data evaluation of experimental data, including parameter analysis, physical analysis, Spline fitting etc.. These methods and codes can be used in many different cases

  1. TEACHER PERFORMANCE EVALUATION

    Directory of Open Access Journals (Sweden)

    Guadalupe Iván Martínez-Chairez

    2015-07-01

    Full Text Available This research report comes from a study that was developed during the school years 2013-2014, 2014-2015, in the southern state of Chihuahua central region, in the education sector 25 consisting of five school zones that provide services to Meoqui municipalities, Julimes and Delicias. The study is a mixed court, correlational comprehensive sequential procedure. Some of the results is that there is a correlation between the 578 years of service of teachers and the score assigned to students in teaching career, but there is no association between teacher performance and the context in which it works, in addition there is no relationship between the teacher performance and school performance of students on standardized tests. 2.4% of the representative sample presented an excellent teacher performance, 7.3% have a bad teacher performance, but it is noteworthy that 39% of teachers observed lies with good teaching performance.

  2. Judd–Ofelt analysis of spectra and experimental evaluation of laser performance of Tm3+ doped Lu2SiO5 crystal

    International Nuclear Information System (INIS)

    Yao Baoquan; Zheng Liangliang; Duan Xiaoming; Zhao Guangjun; Zong Yanhua

    2008-01-01

    This paper reports that the Tm 3+ :Lu 2 SiO 5 (Tm:LSO) crystal is grown by Czochralski technique. The room-temperature absorption spectra of Tm:LSO crystal are measured on a b-cut sample with 4 at.% thulium. According to the obtained Judd–Ofelt intensity parameters Ω 2 = 9.3155 × 10 −20 cm 2 , Ω 4 = 8.4103 × 10 −20 cm 2 ,Ω 6 = 1.5908 × 10 −20 cm 2 , the fluorescence lifetime is calculated to be 2.03 ms for 3 F 4 → 3 H 6 transition, and the integrated emission cross section is 5.81 × 10 −18 cm 2 . Room-temperature laser action near 2μm under diode pumping is experimentally evaluated in Tm:LSO. An optical-optical conversion efficiency of 9.1% and a slope efficiency of 16.2% are obtained with continuous-wave maximum output power of 0.67 W. The emission wavelengths of Tm:LSO laser are centred around 2.06 μm with spectral bandwidth of ∼13.6 nm. (nuclear physics)

  3. NUCLEAR PHYSICS: Judd Ofelt analysis of spectra and experimental evaluation of laser performance of Tm3+ doped Lu2SiO5 crystal

    Science.gov (United States)

    Yao, Bao-Quan; Zheng, Liang-Liang; Duan, Xiao-Ming; Zhao, Guang-Jun; Zong, Yan-Hua

    2008-10-01

    This paper reports that the Tm3+:Lu2SiO5 (Tm:LSO) crystal is grown by Czochralski technique. The room-temperature absorption spectra of Tm:LSO crystal are measured on a b-cut sample with 4 at.% thulium. According to the obtained Judd-Ofelt intensity parameters Ω2 = 9.3155 × 10-20 cm2, Ω4 = 8.4103 × 10-20 cm2,Ω6 = 1.5908 × 10-20 cm2, the fluorescence lifetime is calculated to be 2.03 ms for 3F4 → 3H6 transition, and the integrated emission cross section is 5.81 × 10-18 cm2. Room-temperature laser action near 2μm under diode pumping is experimentally evaluated in Tm:LSO. An optical-optical conversion efficiency of 9.1% and a slope efficiency of 16.2% are obtained with continuous-wave maximum output power of 0.67 W. The emission wavelengths of Tm:LSO laser are centred around 2.06 μm with spectral bandwidth of ~13.6 nm.

  4. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  5. HLA RTI performance evaluation

    CSIR Research Space (South Africa)

    Malinga, L

    2009-07-01

    Full Text Available size of the UDP packet of the network, namely 64 KB, when using the best effort mode. The performance analysis task of the different RTIs was undertaken for two reasons. The first is to re-establish a High Level Architecture (HLA) in our Research... exchange messages over the network with the RTI Gateway process, via TCP sockets or UDP in order to realise the services associated with the RTI. The allocation of CPU resources to the federate and the RTIA process is exclusively managed...

  6. Walmart Experimental Store Performance Stories: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Kozubal, E.; Norton, P.

    2010-08-01

    Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratory for the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, and light-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

  7. Measurements of operator performance - an experimental setup

    International Nuclear Information System (INIS)

    Netland, K.

    1980-01-01

    The human has to be considered as an important element in a process control system, even if the degree of automation is extremely high. Other elements, e.g. computer, displays, etc., can to a large extent be described and quantified. The human (operator), is difficult to describe in a precise way, and it is just as difficult to predict his thinking and acting in a control room environment. Many factors influence his performance, such as: experience, motivation, level of knowledge, training, control environment, job organization, etc. These factors have to a certain degree to be described before guidelines for design of the man-process interfaces and the control room layout can be developed. For decades, the psychological science has obtained knowledge of the human mind and behaviour. This knowledge should have the potential of a positive input on our effort to describe the factors influencing the operator performance. Even if the human is complex, a better understanding of his thinking and acting, and a more precise description of the factors influencing his performance can be obtained. At OECD Halden Reactor Project an experimental set-up for such studies has been developed and implemented in the computer laboratory. The present set-up includes elements as a computer- and display-based control room, a simulator representing a nuclear power plant, training programme for the subjects, and methods for the experiments. Set-up modules allow reconfiguration of experiments. (orig./HP)

  8. Experimental investigation of consumer price evaluations

    NARCIS (Netherlands)

    Z. Sándor (Zsolt); Ph.H.B.F. Franses (Philip Hans)

    2004-01-01

    textabstractWe develop a procedure to collect experimental choice data for estimating consumer preferences with a special focus on consumer price evaluations. For this purpose we employ a heteroskedastic mixed logit model that measures the effect of the way prices are specified on the variance of

  9. The SKB spent fuel corrosion programme. An evaluation of results from the experimental programme performed in the Studsvik Hot Cell Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R. [Forsyth Consulting, Nykoeping (Sweden)

    1997-12-01

    During the last few years, many of the specimens in the SKB programme on the corrosion of spent fuel have been analysed by the ICP-MS technique, shortly after conclusion of the corrosion tests, or by the analysis of archive samples. Together with the previous results, this has made available a much more extended analytical data base than that available before, and this has been used in a new evaluation which complements those published earlier. Some of the new analytical data is for tests performed on fuel specimens (from two reference fuel rods, one BWR and one PWR) which have been corrosion tested for over ten years. Most of the data refers to 16 fuel/clad specimens from a short BWR fuel rod, which had burnups over a range of 27.0 to 48.8 MWd/kg U. Detailed examination and characterisation of three other fuel specimens from the rod had shown that the specimens with the higher burnups in this series would have a fuel microstructure and alpha activity content and distribution which, theoretically, may promote enhanced corrosion. These specimens had been exposed to over 5 years of corrosion during nine water contact periods. The corrodants used were a simulated bicarbonate groundwater and de-ionised water, and both oxic and nominally anoxic conditions were included in the test matrix. Most of the emphasis in the evaluation has, therefore, been on the possible effects on corrosion behaviour of the linear heat rating and burnup of the fuels. However, examination of the variation with water contact time of the fractional release rates of selected fission products and their total release over the five years of corrosion, have shown that the corrosion rates during the first few weeks of corrosion of the specimens with the higher burnups were lower than those for specimens with slightly lower burnup. Later, the corrosion rates converged for all specimens. This has been interpreted to be due to burnup-related differences in the fuel microstructure, particularly in the

  10. The development of human factors experimental evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Bong Shick; Oh, In Suk; Cha, Kyung Ho; Lee, Hyun Chul; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon

    1997-07-01

    New human factors issues, such as evaluation of information navigation, the consideration of operator characteristics, and operator performance assessment, related to the HMI design based on VDUs are being risen. Thus, in order to solve these human factors issues, this project aims to establish the experimental technologies including the techniques for experimental design, experimental measurement, data collection and analysis, and to develop ITF (Integrated Test Facility) suitable for the experiment of HMI design evaluation. For the establish of the experimental data analysis and evaluation methodologies, we developed as the following: (1) a paradigm for human factors experimentation including experimental designs, procedures, and data analysis. (2) the methods for the assessment of operator`s mental workload (3) DAEXESS (data analysis and experiment evaluation supporting system). Also, we have established a experiment execution technologies through the preliminary experiments, such as the suitability evaluation of information display on a LSDP, the evaluation of information display on a LSDP, the evaluation of computerized operation procedure and an experiment of advanced alarm system (ADIOS). Finally, we developed the ITF including human machine simulator, telemetry system, an eye tracking system, an audio/video data measurement system, and three dimensional micro behaviour analysis system. (author). 81 refs., 68 tabs., 73 figs.

  11. Dry Process Fuel Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-15

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  12. Dry Process Fuel Performance Evaluation

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  13. Experimental Study on Revetec Engine Cam Performance

    International Nuclear Information System (INIS)

    Gasim, Maisara Mohyeldin; Chui, Lee Giok; Anwar, Khirul Azhar bin

    2012-01-01

    In Revetec engine (three-lobed) cam replaces the crankshaft to convert the reciprocating motion of the engine piston, to a rotating motion in the drive line. Since the cam controls the piston movement, the cam profile has a great effect on engine performance. In this paper an experimental study was done to a (three- lobed) cam with Cycloidal motion profile but with different ratios between the base circle radius of the cam and the radius of the roller follower. DEWESoft was used to find the displacement and the vibration of the piston, and compare the actual results from the test with the theoretical results from the cam profile equation. The results showed that there is a periods of miss contact between the follower and the cam when the ratio between the base circle radius of the cam and the radius of the roller follower is less than a certain value, and also increasing of vibration. The suggested ratio between the cam and follower radius is to be more than 2:1.

  14. Experimental test of liquid droplet radiator performance

    International Nuclear Information System (INIS)

    Mattick, A.T.; Simon, M.A.

    1986-01-01

    This liquid droplet radiator (LDR) is evolving rapidly as a lightweight system for heat rejection in space power systems. By using recirculating free streams of submillimeter droplets to radiate waste energy directly to space, the LDR can potentially be an order of magnitude lighter than conventional radiator systems which radiate from solid surfaces. The LDR is also less vulnerable to micrometeoroid damage than are conventional radiators, and it has a low transport volume. Three major development issues of this new heat rejection system are the ability to direct the droplet streams with sufficient precision to avoid fluid loss, radiative performance of the array of droplet streams which comprise the radiating elements of the LDR, and the efficacy of the droplet stream collector, again with respect to fluid loss. This paper reports experimental results bearing on the first two issues - droplet aiming in a multikilowatt-sized system, and radiated power from a large droplet array. Parallel efforts on droplet collection and LDR system design are being pursued by several research groups

  15. Performance Evaluations in Audit Firms

    DEFF Research Database (Denmark)

    Riise Johansen, Thomas; Christoffersen, Jeppe

    2017-01-01

    Previous research has only minimally examined the association between the behaviour and performance evaluations of individual auditors beyond the use of efficiency-focused evaluations. We examine the association between dysfunctional auditor behaviour and three evaluation foci: an efficiency focus......, a client focus and a quality focus. Our results, which are based on questionnaire responses from 196 auditors, demonstrate that an efficiency focus is not associated with dysfunctional behaviour. A client focus is found to be associated with dysfunctional behaviour. Finally, and perhaps most importantly......, our results show that it seems possible to limit dysfunctional behaviours through a quality focus in performance evaluations. Our results provide insights of use to practitioners and regulators on how performance evaluations may not only induce but also reduce dysfunctional auditor behaviours....

  16. Experimental evaluation of the effect of compression ratio on performance and emission of SI engine fuelled with gasoline and n-butanol blend at different loads

    Directory of Open Access Journals (Sweden)

    Rinu Thomas

    2016-09-01

    Full Text Available Never ending demand for efficient and less polluting engines have always inspired newer technologies. Extensive study has been done on variable compression ratio, a promising in-cylinder technology, in the recent past. The present work is an experimental investigation to examine the variation of different parameters such as brake thermal efficiency, exhaust gas temperature and emissions with respect to change in compression ratio in a single-cylinder carbureted SI engine at different loads with two different fuels. Experiments were conducted at three different compression ratios (CR = 7:1, 8.5:1 and 10:1. The fuels used in this study are pure gasoline and 20% n-butanol blend (B20 in gasoline. The results showed that brake thermal efficiency increases with CR at all loads. Further, the experimental results showed the scope of improving the part-load efficiency of SI engine by adopting the concept of variable compression ratio (VCR technology, especially when fuels with better anti-knock characteristics are used. The uncertainty analysis of the experiments based on the specifications of the equipment used is also tabulated.

  17. Comparative evaluation of an experimental binder in hot-mix asphalt: correlating the predicted performance of the binder with asphalt testing

    CSIR Research Space (South Africa)

    O'Connell, Johannes S

    2014-07-01

    Full Text Available The binder is an important constituent of an asphalt mix and it affects the overall performance of the mix, especially with regards to permanent deformation and fatigue cracking. The stiffest binder available from the Chevron refinery in the Western...

  18. Revisiting Mutual Fund Performance Evaluation

    OpenAIRE

    Angelidis, Timotheos; Giamouridis, Daniel; Tessaromatis, Nikolaos

    2012-01-01

    Mutual fund manager excess performance should be measured relative to their self-reported benchmark rather than the return of a passive portfolio with the same risk characteristics. Ignoring the self-reported benchmark introduces biases in the measurement of stock selection and timing components of excess performance. We revisit baseline empirical evidence in mutual fund performance evaluation utilizing stock selection and timing measures that address these biases. We introduce a new factor e...

  19. Licensee Performance Evaluation: Phase II

    International Nuclear Information System (INIS)

    Chakoff, H.E.; Speaker, D.M.; Thompson, S.R.; Cohen, S.C.

    1979-08-01

    This report details work performed during the second phase of a two-phase contract to develop methodology for Licensee Performance Evaluation. The Phase I report, NUREG/CR-0110 details initial efforts on the contract. The model developed in Phase I was used to evaluate nine additional facilities for this report. Performance indicators from noncompliance data were also evaluated. Methodology was developed employing the noncompliance indicators and used for 12 case studies. It was found that licensee event report indicators could be more easily identified and utilized than noncompliance indicators based on presently available data systems. However, noncompliance data, appropriately related to cause, could provide real insight into why performance was what it was

  20. Performance evaluation recommendations of nuclear power plants outdoor significant civil structures earthquake resistance. Performance evaluation examples

    International Nuclear Information System (INIS)

    2005-06-01

    The Japan Society of Civil Engineers has updated performance evaluation recommendations of nuclear power plants outdoor significant civil structures earthquake resistance in June 2005. Based on experimental and analytical considerations, analytical seismic models of soils for underground structures, effects of vertical motions on time-history dynamic analysis and shear fracture of reinforced concretes by cyclic loadings have been incorporated in new recommendations. This document shows outdoor civil structures earthquake resistance and endurance performance evaluation examples based on revised recommendations. (T. Tanaka)

  1. Experimental evaluation of the effect of wave focusing walls on the performance of the Sea-wave Slot-cone Generator

    International Nuclear Information System (INIS)

    Oliveira, P.; Taveira-Pinto, F.; Morais, T.; Rosa-Santos, P.

    2016-01-01

    Highlights: • The application of the Sea-wave Slot-cone Generator (SSG) in breakwaters is promising. • The use of wave focusing walls (WFW) improves the performance of the SSG technology. • The WFW concentrate the incident wave energy and increase the overtopping flow rates. • The design of new SSG devices should take into account the eventual use of WFW. • The use of WFW increased the annual energy production approximately to the double. - Abstract: The Sea-wave Slot-cone Generator (SSG) is a multi-level overtopping based wave energy converter that can be installed either nearshore or offshore. The installation in harbor breakwaters and in the shoreline presents several advantages despite the usual exposure to smaller waves than at offshore locations. This work analyzes the effect of wave focusing walls (i.e., wave concentrators) on the performance of isolated SSG units using a physical model built on a geometric scale of 1/40. Seven configurations were defined by changing the opening angle and the crest level of those elements. The use of wave concentrators proved to be advantageous since a wider wave front is captured and the run-up and overtopping phenomena are enhanced on the SSG ramp owing to the wave energy concentration (walls tapering effect). In fact, the total mean power captured increased for all SSG configurations with concentrators in comparison to the base configuration (without concentrators), regardless of the sea state considered. In terms of hydraulic performance, the gain associated to the use of wave concentrators depends on the characteristics of incident waves, being higher for the smaller significant wave heights and the shorter peak wave periods. The hydraulic efficiency, defined as the ratio between the total mean power captured per meter of SSG width and the wave power per meter width of the incident waves, increases with the significant wave height and reduces with the peak wave period in all tested SSG configurations. In

  2. Performance Evaluation of Photovoltaic Solar System with Different Cooling Methods and a Bi-Reflector PV System (BRPVS: An Experimental Study and Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Muhammad Adil Khan

    2017-06-01

    Full Text Available Reducing the price of solar photovoltaic (PV systems has been a constant challenge. Despite recent advances, solar PV systems are still more costly than conventional energy resources. For the first time, this study examines the effectiveness of three different structures/materials: (i silvered glass plane mirror; (ii convex spherical mirrors; and (iii aluminum (Al foil as reflector. Comparative analysis of four different cooling techniques, i.e., water sprinkling system, passive heat sink method, active air fan method, and closed loop method, for enhancement of output power was performed. A novel Bi reflector solar PV system (BRPVS was suggested to control the working of the reflectors. The Al foil enhanced the power output compared to the others. In addition, the effect of using a reflector on the temperature of a solar PV system was studied. High operating temperatures resulted in a decrease in the maximum output power under the same solar radiation conditions. The combined enhancement of the output power by both Al foil BRPVS system and cooling system was almost 22.75–38.55%. An optimal control algorithm to use cooling and BRPVS in an efficient manner is described.

  3. Experimental evaluation of gonadotoxical action of diazolin

    Directory of Open Access Journals (Sweden)

    Breydak O.A.

    2016-12-01

    Full Text Available Evaluation of gonadotoxic effect of diazolin was conducted according to the methodical recommendations. "Methods of experimental studies to establish thresholds of action of industrial poisons on the generative function for the purpose of hygienic regulation". Experiments were carried out on nonlinear white male rats. The preparation was introduced intragastrically within 72 days in a dose of 100 mg / kg (experimental group 1 and 20 mg / kg (2 experimental group, which made up 1/100DL50 and 1/500 DL50. For the assessment of sexual glands microscopic studies of the testes (external examination, weight, size, functional and morphological parameters were used. The parameters obtained during experiments were compared with the results of the control group and values of standards in laboratory animals. Influence of diazolin in the dose of 100 mg/kg (1/100 DL50 resulted in the increase in the total number of sperm cells with simultaneous decrease of their mobility, redox processes, osmotic and acid resistance. However, these changes did not reach statistical significance. Number of dead sperm cells and their pathological forms and indicators of semen-forming epithelium were within the control. Diazolin in the dose of 20 mg/kg (1/500 DL50 and 100 mg/kg (1/100 DL50 shows no gonadotoxical action.

  4. Nicotinamides: Evaluation of thermochemical experimental properties

    International Nuclear Information System (INIS)

    Zhabina, Aleksandra A.; Nagrimanov, Ruslan N.; Emel’yanenko, Vladimir N.; Solomonov, Boris N.; Verevkin, Sergey P.

    2016-01-01

    Highlights: • Vapor pressures measured by transpiration method. • Enthalpies of solution measured using high-precision solution calorimetry. • Enthalpies of fusion measured by DSC. • Sublimation enthalpies derived from transpiration and solution calorimetry in agreement. • Experimental results evaluated and compared with G4 calculations. - Abstract: Vapor pressures of the isomeric 2-, 3-, and 4-pyridinecarboxamides were measured by using the transpiration method. The enthalpies of sublimation/vaporization of these compounds at 298.15 K were derived from vapor pressure temperature dependences. The enthalpies of solution of the isomeric pyridinecarboxamides were measured with the high-precision solution calorimetry. The enthalpies of sublimation of 3- and 4-pyridinecarboxamides were independently derived with help of the solution calorimetry based procedure. The enthalpies of fusion of the pyridinecarboxamides were measured by the DSC. Thermochemical data isomeric pyridinecarboxamides were collected, evaluated, and tested for internal consistency. The high-level G4 quantum-chemical method was used for mutual validation of the experimental and theoretical gas phase enthalpies of formation successfully.

  5. Performance Evaluation of Security Protocols

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Curti, Michele

    2005-01-01

    We use a special operational semantics which drives us in inferring quantitative measures on systems describing cryptographis cryptographic protocols. We assign rates to transitions by only looking at these labels. The rates reflect the distributed architecture running applications and the use...... of possibly different cryptosystems. We then map transition systems to Markov chains and evaluate performance of systems, using standard tools....

  6. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  7. Numerical and experimental evaluation of performance of ...

    Indian Academy of Sciences (India)

    T V Sanand

    1 Liquid Propulsion System Centre, Indian Space Research Organisation,. Valiamala, Thiruvananthapuram 695547, India. 2 Department of Aerospace Engineering, Indian Institute of Space Science and Technology, ..... rocket turbopumps.

  8. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  9. Experimental approaches for evaluating the invasion risk of biofuel crops

    International Nuclear Information System (INIS)

    Luke Flory, S; Sollenberger, Lynn E; Lorentz, Kimberly A; Gordon, Doria R

    2012-01-01

    There is growing concern that non-native plants cultivated for bioenergy production might escape and result in harmful invasions in natural areas. Literature-derived assessment tools used to evaluate invasion risk are beneficial for screening, but cannot be used to assess novel cultivars or genotypes. Experimental approaches are needed to help quantify invasion risk but protocols for such tools are lacking. We review current methods for evaluating invasion risk and make recommendations for incremental tests from small-scale experiments to widespread, controlled introductions. First, local experiments should be performed to identify conditions that are favorable for germination, survival, and growth of candidate biofuel crops. Subsequently, experimental introductions in semi-natural areas can be used to assess factors important for establishment and performance such as disturbance, founder population size, and timing of introduction across variable habitats. Finally, to fully characterize invasion risk, experimental introductions should be conducted across the expected geographic range of cultivation over multiple years. Any field-based testing should be accompanied by safeguards and monitoring for early detection of spread. Despite the costs of conducting experimental tests of invasion risk, empirical screening will greatly improve our ability to determine if the benefits of a proposed biofuel species outweigh the projected risks of invasions. (letter)

  10. Performability Modelling Tools, Evaluation Techniques and Applications

    NARCIS (Netherlands)

    Haverkort, Boudewijn R.H.M.

    1990-01-01

    This thesis deals with three aspects of quantitative evaluation of fault-tolerant and distributed computer and communication systems: performability evaluation techniques, performability modelling tools, and performability modelling applications. Performability modelling is a relatively new

  11. Evaluate Data Center Network Performance

    DEFF Research Database (Denmark)

    Pilimon, Artur

    through a data center network, which is usually built with layer 2 switches and layer 3 routers. The topology of the data center network is crucial for latency in the data communication to and from the data center and between servers in the data center. Tests can be conducted to measure latency and other...... Engineering, scientists evaluate data center network topologies with an SDN-based (Software-Defined Networking) control framework measuring network performance – primarily latency. This can be used to plan data center scaling by testing how a new topology will function before changes are made. Data center...... performance parameters for different data center network topologies. It is however important that tests can be repeated and reproduced to have comparable information from the tests. There are, of course, many topologies that can be used for data center networks. At DTU Fotonik, Department of Photonics...

  12. Computer technique for evaluating collimator performance

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1975-01-01

    A computer program has been developed to theoretically evaluate the overall performance of collimators used with radioisotope scanners and γ cameras. The first step of the program involves the determination of the line spread function (LSF) and geometrical efficiency from the fundamental parameters of the collimator being evaluated. The working equations can be applied to any plane of interest. The resulting LSF is applied to subroutine computer programs which compute corresponding modulation transfer function and contrast efficiency functions. The latter function is then combined with appropriate geometrical efficiency data to determine the performance index function. The overall computer program allows one to predict from the physical parameters of the collimator alone how well the collimator will reproduce various sized spherical voids of activity in the image plane. The collimator performance program can be used to compare the performance of various collimator types, to study the effects of source depth on collimator performance, and to assist in the design of collimators. The theory of the collimator performance equation is discussed, a comparison between the experimental and theoretical LSF values is made, and examples of the application of the technique are presented

  13. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  14. 48 CFR 436.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. Preparation of performance evaluation reports. (a) In addition to the requirements of FAR 36.604, performance evaluation reports shall be prepared for indefinite-delivery type contracts...

  15. Irradiation and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Bae, Ki Kwang; Yang, M. S.; Song, K. C.

    2000-05-01

    The objectives of the project is to establish the performance evaluation system for the experimental verification of DUPIC fuel. The scope and content for successful accomplishment of the phase 1 objectives is established as follows : irradiation test of DUPIC fuel at HANARO using a noninstrument capsule, study on the characteristics of DUPIC pellets, development of the analysis technology on the thermal behaviour of DUPIC fuel, basic design of a instrument capsule. The R and D results of the phase 1 are summarized as follows : - Performance analysis technology development of DUPIC fuel by model development for DUPIC fuel, review on the extendability of code(FEMAXI-IV, FRAPCON-3, ELESTRESS). - Study on physical properties of DUPIC fuel by design and fabrication of the equipment for measuring the thermal property. - HANARO irradiation test of simulated DUPIC fuel by the noninstrument capsule development. - PIE and result analysis

  16. Irradiation and performance evaluation of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ki Kwang; Yang, M S; Song, K C [and others

    2000-05-01

    The objectives of the project is to establish the performance evaluation system for the experimental verification of DUPIC fuel. The scope and content for successful accomplishment of the phase 1 objectives is established as follows : irradiation test of DUPIC fuel at HANARO using a noninstrument capsule, study on the characteristics of DUPIC pellets, development of the analysis technology on the thermal behaviour of DUPIC fuel, basic design of a instrument capsule. The R and D results of the phase 1 are summarized as follows : - Performance analysis technology development of DUPIC fuel by model development for DUPIC fuel, review on the extendability of code(FEMAXI-IV, FRAPCON-3, ELESTRESS). - Study on physical properties of DUPIC fuel by design and fabrication of the equipment for measuring the thermal property. - HANARO irradiation test of simulated DUPIC fuel by the noninstrument capsule development. - PIE and result analysis.

  17. CATTLE PRODUCTIVE PERFORMANCE EVALUATION CONFINED SUBMITTED IMMUNOCASTRATION

    Directory of Open Access Journals (Sweden)

    J. M. Maluf

    2016-09-01

    Full Text Available In order to evaluate the performance and carcass characteristics of cattle cross breeds ½ Aberdeen Angus x ½Nelore and Nelore confined submitted to immunocastration 218 male animals were used, feedlot, averaging 342 kg, divided into three experimental groups, T1: 117 steers ½ Angus x ½ Nelore no castrated (ANC, T2: 51 Nelore steers uncastrated (NNC and T3: 50 Nellore steers immunocastrated (NIC. The experiment lasted 144 days of confinement. The selection of animals for group formation was according to the individual weight, breed, sex condition and age. For immunocastration it wasused Bopriva® vaccine. The rating was finished according to the parameter used by the meatpacking industry ranging from 1 to 5. The experimental design was completely randomized in three groups. For the analyzes the variables studied statistics were submitted to analysis of variance (ANOVA and Tukey test both at the 5% level of significance. The results showed differences (p <0.01 at various features of productive performance and carcass between treatments. For slaughter weight, the ANC animals were higher (with 582.1 kg to Nelore, regardless of sexual condition, and the NNC were in turn heavier than the NIC, 527.4 and 503.7 respectively. Finally, it observed that the use of immunocastration in Nellore animals provided a decrease in productive performance of confined animals, but provided better finish carcass similar to crossbred (ANC.

  18. 48 CFR 2936.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. (a) The HCA must establish procedures to evaluate architect-engineer contractor... reports must be made using Standard Form 1421, Performance Evaluation (Architect-Engineer) as prescribed...

  19. 13 CFR 304.4 - Performance evaluations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Performance evaluations. 304.4... ECONOMIC DEVELOPMENT DISTRICTS § 304.4 Performance evaluations. (a) EDA shall evaluate the management... of at least one (1) other District Organization in the performance evaluation on a cost-reimbursement...

  20. Experimental Evaluation of the Free Piston Engine - Linear Alternator (FPLA)

    Energy Technology Data Exchange (ETDEWEB)

    Leick, Michael T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Moses, Ronald W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report describes the experimental evaluation of a prototype free piston engine - linear alternator (FPLA) system developed at Sandia National Laboratories. The opposed piston design wa developed to investigate its potential for use in hybrid electric vehicles (HEVs). The system is mechanically simple with two - stroke uniflow scavenging for gas exchange and timed port fuel injection for fuel delivery, i.e. no complex valving. Electrical power is extracted from piston motion through linear alternators wh ich also provide a means for passive piston synchronization through electromagnetic coupling. In an HEV application, this electrical power would be used to charge the batteries. The engine - alternator system was designed, assembled and operated over a 2 - year period at Sandia National Laboratories in Livermore, CA. This report primarily contains a description of the as - built system, modifications to the system to enable better performance, and experimental results from start - up, motoring, and hydrogen combus tion tests.

  1. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  2. 48 CFR 236.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Performance evaluation... Architect-Engineer Services 236.604 Performance evaluation. (a) Preparation of performance reports. Use DD Form 2631, Performance Evaluation (Architect-Engineer), instead of SF 1421. (2) Prepare a separate...

  3. Benchmark Evaluation of HTR-PROTEUS Pebble Bed Experimental Program

    International Nuclear Information System (INIS)

    Bess, John D.; Montierth, Leland; Köberl, Oliver

    2014-01-01

    Benchmark models were developed to evaluate 11 critical core configurations of the HTR-PROTEUS pebble bed experimental program. Various additional reactor physics measurements were performed as part of this program; currently only a total of 37 absorber rod worth measurements have been evaluated as acceptable benchmark experiments for Cores 4, 9, and 10. Dominant uncertainties in the experimental keff for all core configurations come from uncertainties in the 235 U enrichment of the fuel, impurities in the moderator pebbles, and the density and impurity content of the radial reflector. Calculations of k eff with MCNP5 and ENDF/B-VII.0 neutron nuclear data are greater than the benchmark values but within 1% and also within the 3σ uncertainty, except for Core 4, which is the only randomly packed pebble configuration. Repeated calculations of k eff with MCNP6.1 and ENDF/B-VII.1 are lower than the benchmark values and within 1% (~3σ) except for Cores 5 and 9, which calculate lower than the benchmark eigenvalues within 4σ. The primary difference between the two nuclear data libraries is the adjustment of the absorption cross section of graphite. Simulations of the absorber rod worth measurements are within 3σ of the benchmark experiment values. The complete benchmark evaluation details are available in the 2014 edition of the International Handbook of Evaluated Reactor Physics Benchmark Experiments

  4. Evaluation of emergency department performance

    DEFF Research Database (Denmark)

    Sørup, Christian Michel; Jacobsen, Peter; Forberg, Jakob Lundager

    2013-01-01

    eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. Results...... measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. Conclusions A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness...... and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study’s results allow for advancement towards improved performance measurement and standardised assessment across EDs....

  5. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  6. Performance evaluation of an automotive thermoelectric generator

    Science.gov (United States)

    Dubitsky, Andrei O.

    Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.

  7. Energy performance evaluation of AAC

    Science.gov (United States)

    Aybek, Hulya

    The U.S. building industry constitutes the largest consumer of energy (i.e., electricity, natural gas, petroleum) in the world. The building sector uses almost 41 percent of the primary energy and approximately 72 percent of the available electricity in the United States. As global energy-generating resources are being depleted at exponential rates, the amount of energy consumed and wasted cannot be ignored. Professionals concerned about the environment have placed a high priority on finding solutions that reduce energy consumption while maintaining occupant comfort. Sustainable design and the judicious combination of building materials comprise one solution to this problem. A future including sustainable energy may result from using energy simulation software to accurately estimate energy consumption and from applying building materials that achieve the potential results derived through simulation analysis. Energy-modeling tools assist professionals with making informed decisions about energy performance during the early planning phases of a design project, such as determining the most advantageous combination of building materials, choosing mechanical systems, and determining building orientation on the site. By implementing energy simulation software to estimate the effect of these factors on the energy consumption of a building, designers can make adjustments to their designs during the design phase when the effect on cost is minimal. The primary objective of this research consisted of identifying a method with which to properly select energy-efficient building materials and involved evaluating the potential of these materials to earn LEED credits when properly applied to a structure. In addition, this objective included establishing a framework that provides suggestions for improvements to currently available simulation software that enhance the viability of the estimates concerning energy efficiency and the achievements of LEED credits. The primary objective

  8. Evaluation of fast experimental reactor claddings, (2)

    International Nuclear Information System (INIS)

    Miura, Makoto; Nagaki, Hiroshi; Koyama, Masahiro; Tanaka, Yasumasa

    1974-01-01

    Thin-walled fine tubes of Type 316 austenitic stainless steel are used for fuel cladding in Joyo (experimental FBR). The material exhibits the change of the mechanical properties in long-time annealing at high temperature, resulting from the precipitation of carbide in structure. In this connection, the experiment and the results on the changes of the microstructure and mechanical properties (proof stress and hardness) are described. The test specimens are the fuel cladding tubes produced for trial for Joyo core and those for FFTF core made in the U.S.A. They were heated between 400 0 and 850 0 C for 1000 hr in vacuum. (Mori, K.)

  9. 48 CFR 36.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Performance evaluation. 36.604 Section 36.604 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION SPECIAL... Performance evaluation. See 42.1502(f) for the requirements for preparing past performance evaluations for...

  10. Performance evaluation and financial market runs

    NARCIS (Netherlands)

    Wagner, W.B.

    2013-01-01

    This paper develops a model in which performance evaluation causes runs by fund managers and results in asset fire sales. Performance evaluation nonetheless is efficient as it disciplines managers. Optimal performance evaluation combines absolute and relative components in order to make runs less

  11. Performance evaluation on vacuum pumps using nanolubricants

    Energy Technology Data Exchange (ETDEWEB)

    Lue, Yeou Feng; Hsu, Yu Chun; Teng, Tun Ping [Dept. of Industrial EducationNational Taiwan Normal University, Taiwan (China)

    2016-09-15

    This study produced alumina (Al{sub 2}O{sub 3}) nanovacuum-pump lubricants (NVALs) by involving the dispersion of Al{sub 2}O{sub 3} nanoparticles in a vacuum-pump lubricant (VAL) with oleic as a dispersant. Experiments were conducted to evaluate the suspension performance, thermal conductivity, viscosity, specific heat, tribological performance and vacuum-pump performance of the NVALs. The experimental results obtained from the vacuum-pump performance tests show that the NVALs with Al{sub 2}O{sub 3} concentration of 0.2 wt.% and oleic concentration of 0.025 wt.% yielded the lowest electricity consumption, conserving 2.39% of electricity compared with the VAL. No marked difference was observed between the temperatures of the vacuum pump using VAL and NVAL. Furthermore, evacuation (i.e., the minimal pressure of -99.5 kPa) was reached faster by the vacuum pump with the NVALs, and the evacuation time could be reduced by 4.91% under optimal conditions. In addition, the vacuum pump with the NVALs exhibited superior overall effectiveness under relatively lower ambient temperatures.

  12. EXPERIMENTAL EVALUATION OF WEDM MACHINED SURFACE WAVINESS

    Directory of Open Access Journals (Sweden)

    Katerina Mouralova

    2016-10-01

    Full Text Available Wire Electrical Discharge Machining (WEDM an unconventional machining technology which has become indispensable in many industries. The typical morphology of a surface machined using the electrical discharge technology is characterized with a large number of craters caused by electro-spark discharges produced during the machining process. The study deals with an evaluation of the machine parameter setting on the profile parameters of surface waviness on samples made of two metal materials Al 99.5 and Ti-6Al-4V. Attention was also paid to an evaluation of the surface morphology using 3D colour filtered and non-filtered images.

  13. Motivation and performance in physical education: an experimental test.

    Science.gov (United States)

    Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo

    2010-01-01

    The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.

  14. Experimental evaluation of vibrations in heat exchangers

    International Nuclear Information System (INIS)

    Martin Ghiselli, A.

    1997-01-01

    Flow induced vibrations may produce damage of heat exchangers, condensers and steam generators tubes. To evaluate this problem a set of tests were developed to know the real support state of the tubes, which have great influence on the vibration response. This paper include a description of the tests and the results obtained applying them on a heat exchanger equipment. (author) [es

  15. compared performances of the experimental digesters of the animal

    African Journals Online (AJOL)

    2014-06-30

    Jun 30, 2014 ... droppings, in different concentrations of Dry Matter (DM), were followed. ... is conditioned largely by the adopted mode of digestion and the physicochemical conditions of ... study proposes the evaluation on an experimental scale, on the one ..... The entry in production of biogas for digester II (with inoculum) ...

  16. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  17. Experimental Acoustic Evaluation of an Auditorium

    Directory of Open Access Journals (Sweden)

    Marina Dana Ţopa

    2012-01-01

    Full Text Available The paper presents a case history: the acoustical analysis of a rectangular auditorium. The following acoustical parameters were evaluated: early decay time, reverberation time, clarity, definition, and center time. The excitation signal was linear sweep sine and additional analysis was carried out: peak-to-noise ratio, reverberation time for empty and occupied room, standard deviation of acoustical parameters, diffusion, and just noticeable differences analysis. Conclusions about room’s destination and modeling were drawn in the end.

  18. Medicare Administrative Contractor Performance Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Centers for Medicare and Medicaid Services (CMS) has compiled a summary of overall Medicare Administrative Contractor (MAC) performance information as measured...

  19. An experimental evaluation of alarm processing and display characteristics

    International Nuclear Information System (INIS)

    O'Hara, J.; Brown, W.; Hallbert, B.; Skraaning, G.Jr.; Persensky, J.; Wachtel, J.

    1998-01-01

    This paper describes a research program sponsored by the U.S. Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluate the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance. operator task performance, situation awareness, and workload were obtained. In addition. operator opinions and evaluations of the alarm processing and display conditions were collected. Numerous strengths

  20. Experimental Performance Analysis of Wireless Links for Healthcare ...

    African Journals Online (AJOL)

    Wireless networking is currently being deployed for various applications. However, the application of wireless networking in healthcare remains a challenge mainly because of security and reliability concerns. This paper presents experimental results of performance analysis of a wireless network for healthcare application ...

  1. MOTIVATION AND PERFORMANCE IN PHYSICAL EDUCATION: AN EXPERIMENTAL TEST

    Directory of Open Access Journals (Sweden)

    Juan A. Moreno

    2010-03-01

    Full Text Available The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls, aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance

  2. Aging evaluation of active components by using performance evaluation

    International Nuclear Information System (INIS)

    Jung, S. K.; Jin, T. E.; Kim, J. S.; Jung, I. S.; Kim, T. R.

    2003-01-01

    Risk analysis and performance evaluation methodology were applied to the aging evaluation of active components in the periodic safety review of Wolsung unit 1. We conclude that evaluation of performance is more effective to discriminate the aging degradation of active component than the evaluation of aging mechanism. It is essential to analyze the common cause failures of low performance components to evaluate the properness of present maintenance system. Past 10 years failure history is used for establishing the performance criteria. Past 2 years failure history is used for the evaluating the recent performance condition. We analyze the failure mode of the components to improve the maintenance system. Performance evaluation methodology is useful for the quantitative evaluation of aging degradation of active components. Analysis on the repeated failures can be useful for the feedback to maintenance plan and interval

  3. An approach for evaluating expert performance in emergency situations

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Kawano, Ryutaro; Yoshimura, Sandanori

    1995-01-01

    To understand expert behavior and define what constitutes good performance in emergency situations in huge and complex plants, human performance evaluation should be made from viewpoints of not only error, but also various cognitive, psychological, and behavioral characteristics. Quantitative and qualitative measures of human performance are proposed for both individual operators and crews, based on the operator performance analysis experiment, among which cognitive and behavioral aspects are the most important. Operator performance should be further analyzed experimentally from the cognitive and behavioral viewpoints, using an evaluation based on various gross indexes considering operator's tasks which should be done in response to plant situations

  4. Portfolio optimization and performance evaluation

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Christensen, Michael

    2013-01-01

    Based on an exclusive business-to-business database comprising nearly 1,000 customers, the applicability of portfolio analysis is documented, and it is examined how such an optimization analysis can be used to explore the growth potential of a company. As opposed to any previous analyses, optimal...... customer portfolios are determined, and it is shown how marketing decision-makers can use this information in their marketing strategies to optimize the revenue growth of the company. Finally, our analysis is the first analysis which applies portfolio based methods to measure customer performance......, and it is shown how these performance measures complement the optimization analysis....

  5. Evaluating judge performance in sport.

    Science.gov (United States)

    Looney, Marilyn A

    2004-01-01

    Many sports, such as, gymnastics, diving, ski jumping, and figure skating, use judges' scores to determine the winner of a competition. These judges use some type of rating scale when judging performances (e.g., figure skating: 0.0 - 6.0). Sport governing bodies have the responsibility of setting and enforcing quality control parameters for judge performance. Given the judging scandals in figure skating at the 1998 and 2002 Olympics, judge performance in sport is receiving greater scrutiny. The purpose of this article is to illustrate how results from Rasch analyses can be used to provide in-depth feedback to judges about their scoring patterns. Nine judges' scores for 20 pairs of figure skaters who competed at the 2002 Winter Olympics were analyzed using a four-faceted (skater pair ability, skating aspect difficulty, program difficulty, and judge severity) Rasch rating scale model that was not common to all judges. Fit statistics, the logical ordering of skating aspects, skating programs, and separation indices all indicated a good fit of the data to the model. The type of feedback that can be given to judges about their scoring pattern was illustrated for one judge (USA) whose performance was flagged as being unpredictable. Feedback included a detailed description of how the rating scale was used; for example, 10% of all marks given by the American judge were unexpected by the model (Z > |2|). Three figures illustrated differences between the judge's observed and expected marks arranged according to the pairs' skating order and final placement in the competition. Scores which may represent "nationalistic bias" or a skating order influence were flagged by looking at these figures. If sport governing bodies wish to improve the performance of their judges, they need to employ methods that monitor the internal consistency of each judge as a many-facet Rasch analysis does.

  6. Experimental Evaluation of Electric Power Grid Visualization Tools in the EIOC

    Energy Technology Data Exchange (ETDEWEB)

    Greitzer, Frank L.; Dauenhauer, Peter M.; Wierks, Tamara G.; Podmore, Robin; Dalton, Angela C.

    2009-12-01

    The present study follows an initial human factors evaluation of four electric power grid visualization tools and reports on an empirical evaluation of two of the four tools: Graphical Contingency Analysis, and Phasor State Estimator. The evaluation was conducted within specific experimental studies designed to measure the impact on decision making performance.

  7. DMFC performance and methanol cross-over: Experimental analysis and model validation

    Energy Technology Data Exchange (ETDEWEB)

    Casalegno, A.; Marchesi, R. [Dipartimento di Energia, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2008-10-15

    A combined experimental and modelling approach is proposed to analyze methanol cross-over and its effect on DMFC performance. The experimental analysis is performed in order to allow an accurate investigation of methanol cross-over influence on DMFC performance, hence measurements were characterized in terms of uncertainty and reproducibility. The findings suggest that methanol cross-over is mainly determined by diffusion transport and affects cell performance partly via methanol electro-oxidation at the cathode. The modelling analysis is carried out to further investigate methanol cross-over phenomenon. A simple model evaluates the effectiveness of two proposed interpretations regarding methanol cross-over and its effects. The model is validated using the experimental data gathered. Both the experimental analysis and the proposed and validated model allow a substantial step forward in the understanding of the main phenomena associated with methanol cross-over. The findings confirm the possibility to reduce methanol cross-over by optimizing anode feeding. (author)

  8. DRACS thermal performance evaluation for FHR

    International Nuclear Information System (INIS)

    Lv, Q.; Wilson, D. F.; Sabharwall, P.

    2015-01-01

    Direct Reactor Auxiliary Cooling System (DRACS) is a passive decay heat removal system proposed for the Fluoride-salt-cooled High-temperature Reactor (FHR) that combines coated particle fuel and a graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops, relying completely on buoyancy as the driving force. These loops are coupled through two heat exchangers, namely, the DRACS Heat Exchanger and the Natural Draft Heat Exchanger. In addition, a fluidic diode is employed to minimize the parasitic flow into the DRACS primary loop and correspondingly the heat loss to the DRACS during normal operation of the reactor, and to keep the DRACS ready for activation, if needed, during accidents. To help with the design and thermal performance evaluation of the DRACS, a computer code using MATLAB has been developed. This code is based on a one-dimensional formulation and its principle is to solve the energy balance and integral momentum equations. By discretizing the DRACS system in the axial direction, a bulk mean temperature is assumed for each mesh cell. The temperatures of all the cells, as well as the mass flow rates in the DRACS loops, are predicted by solving the governing equations that are obtained by integrating the energy conservation equation over each cell and integrating the momentum conservation equation over each of the DRACS loops. In addition, an intermediate heat transfer loop equipped with a pump has also been modeled in the code. This enables the study of flow reversal phenomenon in the DRACS primary loop, associated with the pump trip process. Experimental data from a High-Temperature DRACS Test Facility (HTDF) are not available yet to benchmark the code. A preliminary code validation is performed by using natural circulation experimental data available in the literature, which are as closely relevant as possible. The code is subsequently applied to the HTDF that is under

  9. Loudspeaker Design and Performance Evaluation

    Science.gov (United States)

    Mäkivirta, Aki Vihtori

    A loudspeaker comprises transducers converting an electrical driving signal into sound pressure, an enclosure working as a holder for transducers, front baffle and box to contain and eliminate the rear-radiating audio signal, and electronic components. Modeling of transducers as well as enclosures is treated in Chap. 32 of this handbook. The purpose of the present chapter is to shed light on the design choices and options for the electronic circuits conditioning the electrical signal fed into loudspeaker transducers in order to optimize the acoustic performance of the loudspeaker.

  10. Evaluation channel performance in multichannel environments

    NARCIS (Netherlands)

    Gensler, S.; Dekimpe, M.; Skiera, B.

    2007-01-01

    Evaluating channel performance is crucial for actively managing multiple sales channels, and requires understanding the customers' channel preferences. Two key components of channel performance are (i) the existing customers' intrinsic loyalty to a particular channel and (ii) the channel's ability

  11. Model Performance Evaluation and Scenario Analysis (MPESA)

    Science.gov (United States)

    Model Performance Evaluation and Scenario Analysis (MPESA) assesses the performance with which models predict time series data. The tool was developed Hydrological Simulation Program-Fortran (HSPF) and the Stormwater Management Model (SWMM)

  12. Performance evaluation of Louisiana superpave mixtures.

    Science.gov (United States)

    2008-12-01

    This report documents the performance of Louisiana Superpave mixtures through laboratory mechanistic tests, mixture : volumetric properties, gradation analysis, and early field performance. Thirty Superpave mixtures were evaluated in this : study. Fo...

  13. Performance evaluation of ventilation radiators

    International Nuclear Information System (INIS)

    Myhren, Jonn Are; Holmberg, Sture

    2013-01-01

    A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust-ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions. The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and identify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered. The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20% without sacrificing ventilation efficiency or thermal comfort. Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught. -- Highlights: ► Low temperature heat emitters are currently of interest due to their potential for increasing energy efficiency. ► A ventilation radiator is a combined ventilation and heat emission unit which can be adapted to low temperature heating systems. ► We examine how ventilation radiators can be made to be more efficient in terms of energy consumption and thermal comfort. ► Current work focuses on heat transfer mechanisms and convection fin configuration of ventilation radiators

  14. Tribo-performance evaluation of ecofriendly brake friction composite materials

    Science.gov (United States)

    Kumar, Naresh; Singh, Tej; Grewal, G. S.

    2018-05-01

    This paper presents the potential of natural fibre in brake friction materials. Natural fibre filled ecofriendly brake friction materials were developed without Kevlar fibre evaluated for tribo-performance on a chase friction testing machine following SAE J 661a standard. Experimental results indicated that natural fibre enhances the fade performance, but depresses the friction and wear performance, whereas Kevlar fibre improves the friction, wear and recovery performance but depresses the fade performance. Also the results revealed that with the increase in natural fibre content, the friction and fade performances enhanced.

  15. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  16. WWER reactor fuel performance, modelling and experimental support. Proceedings

    International Nuclear Information System (INIS)

    Stefanova, S.; Chantoin, P.; Kolev, I.

    1994-01-01

    This publication is a compilation of 36 papers presented at the International Seminar on WWER Reactor Fuel Performance, Modelling and Experimental Support, organised by the Institute for Nuclear Research and Nuclear Energy (BG), in cooperation with the International Atomic Energy Agency. The Seminar was attended by 76 participants from 16 countries, including representatives of all major Russian plants and institutions responsible for WWER reactor fuel manufacturing, design and research. The reports are grouped in four chapters: 1) WWER Fuel Performance and Economics: Status and Improvement Prospects: 2) WWER Fuel Behaviour Modelling and Experimental Support; 3) Licensing of WWER Fuel and Fuel Analysis Codes; 4) Spent Fuel of WWER Plants. The reports from the corresponding four panel discussion sessions are also included. All individual papers are recorded in INIS as separate items

  17. WWER reactor fuel performance, modelling and experimental support. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Stefanova, S; Chantoin, P; Kolev, I [eds.

    1994-12-31

    This publication is a compilation of 36 papers presented at the International Seminar on WWER Reactor Fuel Performance, Modelling and Experimental Support, organised by the Institute for Nuclear Research and Nuclear Energy (BG), in cooperation with the International Atomic Energy Agency. The Seminar was attended by 76 participants from 16 countries, including representatives of all major Russian plants and institutions responsible for WWER reactor fuel manufacturing, design and research. The reports are grouped in four chapters: (1) WWER Fuel Performance and Economics: Status and Improvement Prospects: (2) WWER Fuel Behaviour Modelling and Experimental Support; (3) Licensing of WWER Fuel and Fuel Analysis Codes; (4) Spent Fuel of WWER Plants. The reports from the corresponding four panel discussion sessions are also included. All individual papers are recorded in INIS as separate items.

  18. EXPERIMENTAL ANALYSIS OF THE CHARACTERISTIC PERFORMANCE OF STANDALONE PHOTOVOLTAIC SYSTEM

    OpenAIRE

    Birendra Kishore; Anirban Nandy*; O.P. Pandey

    2016-01-01

    This paper demonstrates an insight solar PV Stand Alone system which is a practical model with a halogen light source. At different situations the performance of solar PV cells are analyzed. The system produces power with depending on the change in halogen light intensity & temperature. A theoretical & experimental analysis of the PV cell can be achieved. In this paper the I-V & P-V characteristic of the solar photovoltaic cells with changes in temperature and isolation have been showed. With...

  19. Learning and performance under alternative instructional manifestations of experimental practice

    Science.gov (United States)

    Ford, Michael J.

    Before we can understand how students learn "to do" science, we must make explicit our assumptions about what scientific practice is. This study compares the learning outcomes of two sixth-grade instructional units on experimentation, each based on a particular characterization of practice. In one unit, instruction focused on acquisition and application of the control of variables strategy (CVS; Chen & Klahr, 1999), which is consistent with a popular conception of science education, stemming from Piaget, as the mastery of logical forms. In the other unit, students designed experimental apparatus to answer a target question, and instruction emphasized practices of rendering and transforming the material world in ways that support scientific understanding. Students in both groups were assessed for CVS acquisition and subsequent experimental performance on a novel task, and group performances on these assessments different across instructional conditions. I will argue that student understandings of goals, norms of instructional expectation, and strategies explain these differences, in some cases by supporting performance and in other cases by hindering it. I will also argue that the results question the role typically attributed to logical method in learning to design experiments.

  20. Theoretical and experimental analysis of fast reactor fuel performance

    International Nuclear Information System (INIS)

    Kummerer, K.R.; Freund, D.; Steiner, H.

    1982-09-01

    In order to predict behavior, performance, and capability of prototypic fuel pins a standard operational scheme for the SNR-300 fast breeder reactor is established considering besides normal operation unscheduled power changes and shutdowns. The behavior during the whole lifetime is calculated using the updated SATURN codes and - for special conditions as power transients and skewed fuel rod power - the new TRANSIENT and TEXDIF codes. The results of these calculations are compared to experimental findings. It is demonstrated that the level of modeling and the knowledge of material properties under irradiation are sufficient for a quantitative description of the fuel pin performance under the above mentioned conditions. (orig.) [de

  1. Experimental results pertaining to the performance of thermal igniters

    International Nuclear Information System (INIS)

    Carmel, M.K.

    1989-10-01

    This report summarizes the results of various experimental programs regarding the performance of thermal igniters for the deliberate ignition of hydrogen in light water reactors. Experiments involving both premixed combustion and combustion with continuous hydrogen injection are reviewed. Combustion characteristics examined include flammability limits of hydrogen:air and hydrogen:air:steam mixtures, combustion pressure rises, combustion completeness, flame speeds, and heat transfer aspects. Comparisons of igniter type and igniter reliability under simulated reactor accident conditions are included. The results of the research programs provide a broad data base covering nearly all aspects of hydrogen combustion related to the performance of deliberate ignition systems

  2. Methodology for quantitative evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.

    1981-01-01

    Of various approaches that might be taken to the diagnostic performance evaluation problem, Receiver Operating Characteristic (ROC) analysis holds great promise. Further development of the methodology for a unified, objective, and meaningful approach to evaluating the usefulness of medical imaging procedures is done by consideration of statistical significance testing, optimal sequencing of correlated studies, and analysis of observer performance

  3. Experimental evaluation of control strategies for hydraulic servo robot

    DEFF Research Database (Denmark)

    Bech, Michael Møller; Andersen, Torben Ole; Pedersen, Henrik C.

    2013-01-01

    In this paper different linear and non-linear controllers applied to a hydraulically driven servo robot are evaluated and validated. The task is to make the actuators of the manipulator track a position reference with minimum error. Hydraulic systems are intrinsically non-linear and using linear...... in industrial servo drives. The different controllers are compared and evaluated from simulation and experimental results....

  4. Experimental study on performance of pulsed liquid jet pump

    International Nuclear Information System (INIS)

    Xu Weihui; Gao Chuanchang; Qin Haixia

    2010-01-01

    The device performance characteristics of transformer type pulsed liquid pump device were experimentally studied. The effects of the area ratio, work pressure and pulse parameters on the performance of the pulsed liquid jet pump device were performed in the tests. The potency of pulsed jet on improving the performance of the liquid jet pump device was also studied through the comparison with invariable jet pump at the same conditions. The results show that the pulsed jet can significantly improve the performance of transformer type jet pump devices. Area ratio and pulse parameters are the critical factors to the performance of the pulsed liquid jet pump device. The jet pump device performances are significantly improved by reducing the area ratio or by increasing the pulsed frequency. The flux characteristics of the pulsed liquid jet pump device presents the typical negative linear,the potency of pulsed jet in improving the performance of jet pump device with small area ratio can be more significant. The efficiency curve of pulsed liquid jet pump is similar to the parabola. At higher pulsed frequency, the top efficiency point of the pulsed jet pump moves to the higher flow ratio. The high efficiency area of the pulsed jet pump also is widened with the increase of the pulsed frequency. (authors)

  5. PERFORMANCE EVALUATION: LITERATURE REVIEW AND TIME EVOLUTION.

    Directory of Open Access Journals (Sweden)

    Pintea Mirela-Oana

    2012-07-01

    Full Text Available Performance evaluation of an economic entity requires approaching several criteria, such as industry and economic entity type, managerial and entrepreneurial strategy, competitive environment, human and material resources available, using a system of appropriate performance indicators for this purpose.The exigencies of communication occurred on the growing number of phenomena that marked the global economy in recent decades (internationalization and relocation of business crises and turmoil in financial markets, demand performance measurement to be made in a comprehensive way by financial and non-financial criteria. Indicators are measures of performance used by management to measure, report and improve performance of the economic entity. The relationship between indicators and management is ensured by the existence of performance measurement systems. Studies to date indicate that economic entities using balanced performance measurement systems as a key management tool registered superior performance compared to entities not using such systems. This study attempts to address the issue of performance evaluation by presenting opinions of different authors concerning the process of performance measurement and to present, after revising the literature, the evolution of the performance evaluation systems. We tried to do this literature review because sustainable development and, therefore, globalization require new standards of performance that exceeds the economic field, both for domestic companies as well as international ones. So, these standards should be integrated into corporate strategy development to ensure sustainability of activities undertaken by harmonizing the economic, social and environmental objectives. To assess the performance of economic entities it is required that performance evaluation to be done with a balanced multidimensional system, including both financial ratios and non-financial indicators in order to reduce the limits of

  6. Development and performance evaluation of a guided horizontal ...

    African Journals Online (AJOL)

    ... and tested on the rice field of National Cereals Research Institute (NCRI), Moor plantation, Ibadan, to evaluate the performance of the machine. A 22 x 3 factorial experimental design with two replicates was used to analysis the effect of engine speed (1200, 1400 and 1800rpm), ecology (irrigated and rainfed-lowland) and ...

  7. Spent Fuel Transportation Package Performance Study - Experimental Design Challenges

    International Nuclear Information System (INIS)

    Snyder, A. M.; Murphy, A. J.; Sprung, J. L.; Ammerman, D. J.; Lopez, C.

    2003-01-01

    Numerous studies of spent nuclear fuel transportation accident risks have been performed since the late seventies that considered shipping container design and performance. Based in part on these studies, NRC has concluded that the level of protection provided by spent nuclear fuel transportation package designs under accident conditions is adequate. [1] Furthermore, actual spent nuclear fuel transport experience showcase a safety record that is exceptional and unparalleled when compared to other hazardous materials transportation shipments. There has never been a known or suspected release of the radioactive contents from an NRC-certified spent nuclear fuel cask as a result of a transportation accident. In 1999 the United States Nuclear Regulatory Commission (NRC) initiated a study, the Package Performance Study, to demonstrate the performance of spent fuel and spent fuel packages during severe transportation accidents. NRC is not studying or testing its current regulations, a s the rigorous regulatory accident conditions specified in 10 CFR Part 71 are adequate to ensure safe packaging and use. As part of this study, NRC currently plans on using detailed modeling followed by experimental testing to increase public confidence in the safety of spent nuclear fuel shipments. One of the aspects of this confirmatory research study is the commitment to solicit and consider public comment during the scoping phase and experimental design planning phase of this research

  8. Experimental evaluation of an expert system for nuclear reactor operators

    International Nuclear Information System (INIS)

    Nelson, W.R.

    1984-10-01

    The United States Nuclear Regulatory Commission (USNRC) is supporting a program for the experimental evaluation of an expert system for nuclear reactor operators. A prototype expert system, called the Response Tree System, has been developed and implemented at INEL. The Response Tree System is designed to assess the status of a reactor system following an accident and recommend corrective actions to reactor operators. The system is implemented using color graphic displays and is driven by a computer simulation of the reactor system. Control of the system is accomplished using a transparent touch panel. Controlled experiments are being conducted to measure performance differences between operators using the Response Tree System and those not using it to respond to simulated accident situations. This paper summarizes the methodology and results of the evaluation of the Response Tree System, including the quantitative results obtained in the experiments thus far. Design features of the Response Tree System are discussed, and general conclusions regarding the applicability of expert systems in reactor control rooms are presented

  9. Unsupervised Performance Evaluation of Image Segmentation

    Directory of Open Access Journals (Sweden)

    Chabrier Sebastien

    2006-01-01

    Full Text Available We present in this paper a study of unsupervised evaluation criteria that enable the quantification of the quality of an image segmentation result. These evaluation criteria compute some statistics for each region or class in a segmentation result. Such an evaluation criterion can be useful for different applications: the comparison of segmentation results, the automatic choice of the best fitted parameters of a segmentation method for a given image, or the definition of new segmentation methods by optimization. We first present the state of art of unsupervised evaluation, and then, we compare six unsupervised evaluation criteria. For this comparative study, we use a database composed of 8400 synthetic gray-level images segmented in four different ways. Vinet's measure (correct classification rate is used as an objective criterion to compare the behavior of the different criteria. Finally, we present the experimental results on the segmentation evaluation of a few gray-level natural images.

  10. Shock circle model for ejector performance evaluation

    International Nuclear Information System (INIS)

    Zhu, Yinhai; Cai, Wenjian; Wen, Changyun; Li, Yanzhong

    2007-01-01

    In this paper, a novel shock circle model for the prediction of ejector performance at the critical mode operation is proposed. By introducing the 'shock circle' at the entrance of the constant area chamber, a 2D exponential expression for velocity distribution is adopted to approximate the viscosity flow near the ejector inner wall. The advantage of the 'shock circle' analysis is that the calculation of ejector performance is independent of the flows in the constant area chamber and diffuser. Consequently, the calculation is even simpler than many 1D modeling methods and can predict the performance of critical mode operation ejectors much more accurately. The effectiveness of the method is validated by two experimental results reported earlier. The proposed modeling method using two coefficients is shown to produce entrainment ratio, efficiency and coefficient of performance (COP) accurately and much closer to experimental results than those of 1D analysis methods

  11. Evaluation of an Experimental Adhesive Resin for Orthodontic Bonding

    Science.gov (United States)

    Durgesh, B. H.; Alkheraif, A. A.; Pavithra, D.; Hashem, M. I.; Alkhudhairy, F.; Elsharawy, M.; Divakar, D. D.; Vallittu, P. K.; Matinlinna, J. P.

    2017-07-01

    The aim of this study was to evaluate in vitro the effect of an experimental adhesive resin for orthodontic bonding by measuring some the chemical and mechanical properties. The resin demonstrated increased values of nanohardness and elastic modulus, but the differences were not significant compared with those for the Transbond XT adhesives. The experimental adhesive resin could be a feasible choice or a substitute for the traditional bis-GMA-based resins used in bonding orthodontic attachments.

  12. NPP Krsko natural circulation performance evaluation

    International Nuclear Information System (INIS)

    Segon, Velimir; Bajs, Tomislav; Frogheri, Monica

    1999-01-01

    The present document deals with an evaluation of the natural circulation performance of the Krsko nuclear power plant. Two calculation have been performed using the NPP Krsko nodalization (both similar to the LOBI A2-77 natural circulation experiment) - the first with the present steam generators at NPP Krsko (Westinghouse, 18% plugged), the second with the future steam generators (Siemens, 0% plugged). The results were evaluated using the natural circulation flow map derived in /1/, and were compared to evaluate the influence of the new steam generators on the natural circulation performance. (author)

  13. Criteria of the validation of experimental and evaluated covariance data

    International Nuclear Information System (INIS)

    Badikov, S.

    2008-01-01

    The criteria of the validation of experimental and evaluated covariance data are reviewed. In particular: a) the criterion of the positive definiteness for covariance matrices, b) the relationship between the 'integral' experimental and estimated uncertainties, c) the validity of the statistical invariants, d) the restrictions imposed to correlations between experimental errors, are described. Applying these criteria in nuclear data evaluation was considered and 4 particular points have been examined. First preserving positive definiteness of covariance matrices in case of arbitrary transformation of a random vector was considered, properties of the covariance matrices in operations widely used in neutron and reactor physics (splitting and collapsing energy groups, averaging the physical values over energy groups, estimation parameters on the basis of measurements by means of generalized least squares method) were studied. Secondly, an algorithm for comparison of experimental and estimated 'integral' uncertainties was developed, square root of determinant of a covariance matrix is recommended for use in nuclear data evaluation as a measure of 'integral' uncertainty for vectors of experimental and estimated values. Thirdly, a set of statistical invariants-values which are preserved in statistical processing was presented. And fourthly, the inequality that signals a correlation between experimental errors that leads to unphysical values is given. An application is given concerning the cross-section of the (n,t) reaction on Li 6 with a neutron incident energy comprised between 1 and 100 keV

  14. Relative Performance of Indoor Vector Control Interventions in the Ifakara and the West African Experimental Huts.

    OpenAIRE

    Oumbouke, Welbeck A; Fongnikin, Augustin; Soukou, Koffi B; Moore, Sarah J; N'Guessan, Raphael

    2017-01-01

    Background West African and Ifakara experimental huts are used to evaluate indoor mosquito control interventions, including spatial repellents and insecticides. The two hut types differ in size and design, so a side-by-side comparison was performed to investigate the performance of indoor interventions in the two hut designs using standard entomological outcomes: relative indoor mosquito density (deterrence), exophily (induced exit), blood-feeding and mortality of mosquitoes. Methods Metoflut...

  15. Conductor gestures influence evaluations of ensemble performance.

    Science.gov (United States)

    Morrison, Steven J; Price, Harry E; Smedley, Eric M; Meals, Cory D

    2014-01-01

    Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor's gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance: articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and non-majors (N = 285) viewed sixteen 30 s performances and evaluated the quality of the ensemble's articulation, dynamics, technique, and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble's performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity.

  16. Conductor gestures influence evaluations of ensemble performance

    Directory of Open Access Journals (Sweden)

    Steven eMorrison

    2014-07-01

    Full Text Available Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor’s gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance, articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and nonmajors (N = 285 viewed sixteen 30-second performances and evaluated the quality of the ensemble’s articulation, dynamics, technique and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble’s performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity.

  17. MATLAB platform for Monte Carlo planning and dosimetry experimental evaluation

    International Nuclear Information System (INIS)

    Baeza, J. A.; Ureba, A.; Jimenez-Ortega, E.; Pereira-Barbeiro, A. R.; Leal, A.

    2013-01-01

    A new platform for the full Monte Carlo planning and an independent experimental evaluation that it can be integrated into clinical practice. The tool has proved its usefulness and efficiency and now forms part of the flow of work of our research group, the tool used for the generation of results, which are to be suitably revised and are being published. This software is an effort of integration of numerous algorithms of image processing, along with planning optimization algorithms, allowing the process of MCTP planning from a single interface. In addition, becomes a flexible and accurate tool for the evaluation of experimental dosimetric data for the quality control of actual treatments. (Author)

  18. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    Directory of Open Access Journals (Sweden)

    Swati R Yedke

    2013-01-01

    Full Text Available Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3 rd and 7 th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries.

  19. Experimental Verification Of Hyper-V Performance Isolation Level

    Directory of Open Access Journals (Sweden)

    Krzysztof Rzecki

    2014-01-01

    Full Text Available The need for cost optimization in a broad sense constitutes the basis of operation of every enterprise. In the case of IT structure, which is present in almost every field of activity these days, one of the most commonly applied technologies leading to good cost-to-profit adjustment is virtualization. It consists in locating several operational systems with IT systems on a single server. In order for such optimization to be carried out correctly it has to be strictly controlled by means of allocating access to resources, which is known as performance isolation. Modern virtualizers allow to set up this allocation in quantitative terms (the number of processors, size of RAM, or disc space. It appears, however, that in qualitative terms (processor's time, RAM or hard disc bandwidth the actual allocation of resources does not always correspond with this configuration. This paper provides an experimental presentation of the achievable level of performance isolation of the Hyper-V virtualizer.

  20. Experimental Methods for UAV Aerodynamic and Propulsion Performance Assessment

    Directory of Open Access Journals (Sweden)

    Stefan ANTON

    2015-06-01

    Full Text Available This paper presents an experimental method for assessing the performances and the propulsion power of a UAV in several points based on telemetry. The points in which we make the estimations are chosen based on several criteria and the fallowing parameters are measured: airspeed, time-to-climb, altitude and the horizontal distance. With the estimated propulsion power and knowing the shaft motor power, the propeller efficiency is determined at several speed values. The shaft motor power was measured in the lab using the propeller as a break. Many flights, using the same UAV configuration, were performed before extracting flight data, in order to reduce the instrumental or statistic errors. This paper highlights both the methodology of processing the data and the validation of theoretical results.

  1. Laboratory performance evaluation reports for management

    International Nuclear Information System (INIS)

    Lindahl, P.C.; Hensley, J.E.; Bass, D.A.; Johnson, P.L.; Marr, J.J.; Streets, W.E.; Warren, S.W.; Newberry, R.W.

    1995-01-01

    In support of the US DOE's environmental restoration efforts, the Integrated Performance Evaluation Program (IPEP) was developed to produce laboratory performance evaluation reports for management. These reports will provide information necessary to allow DOE headquarters and field offices to determine whether or not contracted analytical laboratories have the capability to produce environmental data of the quality necessary for the remediation program. This document describes the management report

  2. Evaluation of high-performance computing software

    Energy Technology Data Exchange (ETDEWEB)

    Browne, S.; Dongarra, J. [Univ. of Tennessee, Knoxville, TN (United States); Rowan, T. [Oak Ridge National Lab., TN (United States)

    1996-12-31

    The absence of unbiased and up to date comparative evaluations of high-performance computing software complicates a user`s search for the appropriate software package. The National HPCC Software Exchange (NHSE) is attacking this problem using an approach that includes independent evaluations of software, incorporation of author and user feedback into the evaluations, and Web access to the evaluations. We are applying this approach to the Parallel Tools Library (PTLIB), a new software repository for parallel systems software and tools, and HPC-Netlib, a high performance branch of the Netlib mathematical software repository. Updating the evaluations with feed-back and making it available via the Web helps ensure accuracy and timeliness, and using independent reviewers produces unbiased comparative evaluations difficult to find elsewhere.

  3. Performance-Based Evaluation and School Librarians

    Science.gov (United States)

    Church, Audrey P.

    2015-01-01

    Evaluation of instructional personnel is standard procedure in our Pre-K-12 public schools, and its purpose is to document educator effectiveness. With Race to the Top and No Child Left Behind waivers, states are required to implement performance-based evaluations that demonstrate student academic progress. This three-year study describes the…

  4. Building Leadership Talent through Performance Evaluation

    Science.gov (United States)

    Clifford, Matthew

    2015-01-01

    Most states and districts scramble to provide professional development to support principals, but "principal evaluation" is often lost amid competing priorities. Evaluation is an important method for supporting principal growth, communicating performance expectations to principals, and improving leadership practice. It provides leaders…

  5. Performance Evaluation Of Behavioral Biometric Systems

    OpenAIRE

    Cherifi , Fouad; Hemery , Baptiste; Giot , Romain; Pasquet , Marc; Rosenberger , Christophe

    2009-01-01

    We present in this chapter an overview of techniques for the performance evaluation of behavioral biometric systems. The BioAPI standard that defines the architecture of a biometric system is presented in the first part of the chapter... The general methodology for the evaluation of biometric systems is given including statistical metrics, definition of benchmark databases and subjective evaluation. These considerations rely with the ISO/IEC19795-1 standard describing the biometric performanc...

  6. Experimental Evaluations of Selected Immersion Hypothermia Protection Equipment.

    Science.gov (United States)

    1979-10-12

    the research were Jim Strawhorn, Tom Horseman and Jay Smith. ii Srb "Peeat~loj 0",___e_____._______ . TABLE OF CONTENTS EXPERIMENTAL EVALUATIONS OF...In death . Insulating the body will decrease the amount of heat removed. The thickness of an Insulation layer and the type of material from which it is

  7. Contribution of computer science to the evaluation of experimental data

    International Nuclear Information System (INIS)

    Steuerwald, J.

    1978-11-01

    The GALE data acquisition system and EDDAR data processing system, used at Max-Planck-Institut fuer Plasmaphysik, serve to illustrate some of the various ways in which computer science plays a major role in developing the evaluation of experimental data. (orig.) [de

  8. Sexual Violence Prevention through Bystander Education: An Experimental Evaluation

    Science.gov (United States)

    Banyard, Victoria L.; Moynihan, Mary M.; Plante, Elizabethe G.

    2007-01-01

    The current study used an experimental design to evaluate a sexual violence prevention program based on a community of responsibility model that teaches women and men how to intervene safely and effectively in cases of sexual violence before, during, and after incidents with strangers, acquaintances, or friends. It approaches both women and men as…

  9. Experimental investigation of a super performance dew point air cooler

    International Nuclear Information System (INIS)

    Xu, Peng; Ma, Xiaoli; Zhao, Xudong; Fancey, Kevin

    2017-01-01

    Highlights: •The cooler had a complex heat & mass exchanger with an advanced wet material layer. •Intermittent water supply scheme was implemented. •The cooler achieved 100–160% higher COP compared to the existing dew point coolers. •Electricity use of the cooler was reduced by 50–70% compared to existing dew coolers. •This optimal working air ratio was 0.364 that enabled maximised cooling effectiveness. -- Abstract: This paper presents an experimental investigation of a super performance dew point air cooler which, by employing a super performance wet material layer, innovative heat and mass exchanger and intermittent water supply scheme, has achieved a significantly higher energy efficiency (i.e. Coefficient of Performance, COP) and a much lower electrical energy use compared to the existing air coolers of the same type. This involves the dedicated system design & construction, fully planned experimental testing under various simulated climatic conditions representing the climate of hot & dry, warm & dry, moderate, warm & humid and standard lab testing condition, testing results analysis and discussion, as well as the parallel comparison against the commercial dew point air cooler. Under the standard test condition, i.e. dry bulb temperature of 37.8 °C and coincident wet bulb temperature of 21.1 °C, the prototype cooler achieved the wet-bulb cooling effectiveness of 114% and dew-point cooling effectiveness of 75%, yielding a significantly high COP value of 52.5 at the optimal working air ratio of 0.364. The testing also indicated that the lower inlet air relative humidity led to a higher cooling efficiency, while the lower cooling output helped increase COP and cooling effectiveness (including the wet-bulb effectiveness and dew-point effectiveness) of the cooler.

  10. Synthesis of analytical and experimental data, capacity evaluation

    International Nuclear Information System (INIS)

    Lin Chiwenn

    2001-01-01

    This part of the presentation deals with the synthesis of analytical and experimental data and capacity evaluation. First, a typical test flow diagram will be discussed to identify key aspects of the test program where analysis is to be performed. Next, actual component test and analysis programs will be presented to illustrate some important parameters to be considered in the modelling process. Then, two combined test and analysis projects will be reviewed to demonstrate the potential use of substructuring in the model testing to reduce the size of the model to be tested. This will be followed by an inelastic response spectral reactor coolant loop analysis, which was used to study a high level seismic test conducted for a PWR reactor coolant system. The potential use of an improved impact calculation method will be discussed after that. As a closure to the test and analysis synthesis process, a reactor internal qualification process will be discussed. Finally, capacity evaluation will be discussed, following the requirements of ASME section III code for class 1 pressure vessel, class 1 piping which includes the reactor coolant loop piping, and the reactor internals. The subsections included in this part of presentation which cover the above mentioned subjects: typical component test and analysis results; combined test and analysis process; a simplified inelastic response spectral; analysis of reactor coolant loop; an improved impact analysis methodology; reactor coolant system and core internal qualification process; ASME section III code, design by analysis of class 1 pressure vessel; design by analysis of class 1 piping; SME section III code, design by analysis of reactor core internals

  11. Performance Evaluation and Modelling of Container Terminals

    Science.gov (United States)

    Venkatasubbaiah, K.; Rao, K. Narayana; Rao, M. Malleswara; Challa, Suresh

    2018-02-01

    The present paper evaluates and analyzes the performance of 28 container terminals of south East Asia through data envelopment analysis (DEA), principal component analysis (PCA) and hybrid method of DEA-PCA. DEA technique is utilized to identify efficient decision making unit (DMU)s and to rank DMUs in a peer appraisal mode. PCA is a multivariate statistical method to evaluate the performance of container terminals. In hybrid method, DEA is integrated with PCA to arrive the ranking of container terminals. Based on the composite ranking, performance modelling and optimization of container terminals is carried out through response surface methodology (RSM).

  12. Performance evaluation of Central European companies

    Directory of Open Access Journals (Sweden)

    Petr Fiala

    2015-10-01

    Full Text Available The paper presents a modelling approach for performance comparison of Central European companies on three levels: country, industry, and company. The approach is based on Data Envelopment Analysis and Analytic Hierarchy Process. The proposed model consists of two basic sections. The first section estimates the importance of selected industries in the countries, whereas the second section evaluates the performance of companies within industries. The results of both sections are synthesized and finally the country performance is estimated. The evaluation is based on the data set resulting from a survey of companies from selected industries.

  13. Methodology for evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.E.

    1992-01-01

    Effort in this project during the past year has focused on the development, refinement, and distribution of computer software that will allow current Receiver Operating Characteristic (ROC) methodology to be used conveniently and reliably by investigators in a variety of evaluation tasks in diagnostic medicine; and on the development of new ROC methodology that will broaden the spectrum of evaluation tasks and/or experimental settings to which the fundamental approach can be applied. Progress has been limited by the amount of financial support made available to the project

  14. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  15. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  16. Performance Evaluation Model for Application Layer Firewalls.

    Science.gov (United States)

    Xuan, Shichang; Yang, Wu; Dong, Hui; Zhang, Jiangchuan

    2016-01-01

    Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers). Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  17. Performance Evaluation Model for Application Layer Firewalls.

    Directory of Open Access Journals (Sweden)

    Shichang Xuan

    Full Text Available Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers. Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  18. Experimental and Numerical Investigation on Tribological Performance of Grooved Texture

    Directory of Open Access Journals (Sweden)

    CHEN Ping

    2016-06-01

    Full Text Available In order to study the influence of the angle and arrangement forms of micro-grooves on the tribological performance of the contact surface, the finite element analysis software was used to simulate the grooved textures with different angles and arrangements. The YLP-20 laser processing system was used to process grooved texture on stainless steel disk surfaces, and the Tribometer (UMT-2 was also used to conduct tribological test under the condition of rotation. The results show that the numerical simulation values are basically consistent with experimental results of grooved textures, and the tribological performance of the friction pairs with textures is also improved. The grooved textures with different angles and arrangement forms have different influence on tribological performance of friction pairs. When the friction velocity is less than 300r/min, the parallel texture with 0° has smaller friction coefficients. While the friction velocity is larger than 300r/min, the parallel texture with 90° has a better ability of reducing friction. Therefore, different grooved textures should be chosen according to operation conditions.

  19. An Experimental Evaluation of Blockage Corrections for Current Turbines

    Science.gov (United States)

    Ross, Hannah; Polagye, Brian

    2017-11-01

    Flow confinement has been shown to significantly alter the performance of turbines that extract power from water currents. These performance effects are related to the degree of constraint, defined by the ratio of turbine projected area to channel cross-sectional area. This quantity is referred to as the blockage ratio. Because it is often desirable to adjust experimental observations in water channels to unconfined conditions, analytical corrections for both wind and current turbines have been derived. These are generally based on linear momentum actuator disk theory but have been applied to turbines without experimental validation. This work tests multiple blockage corrections on performance and thrust data from a cross-flow turbine and porous plates (experimental analogues to actuator disks) collected in laboratory flumes at blockage ratios ranging between 10 and 35%. To isolate the effects of blockage, the Reynolds number, Froude number, and submergence depth were held constant while the channel width was varied. Corrected performance data are compared to performance in a towing tank at a blockage ratio of less than 5%. In addition to examining the accuracy of each correction, underlying assumptions are assessed to determine why some corrections perform better than others. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. DGE-1256082 and the Naval Facilities Engineering Command (NAVFAC).

  20. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...... to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo...

  1. An experimental study on improvement of Savonius rotor performance

    Directory of Open Access Journals (Sweden)

    N.H. Mahmoud

    2012-03-01

    In this work different geometries of Savonius wind turbine are experimentally studied in order to determine the most effective operation parameters. It was found that, the two blades rotor is more efficient than three and four ones. The rotor with end plates gives higher efficiency than those of without end plates. Double stage rotors have higher performance compared to single stage rotors. The rotors without overlap ratio (β are better in operation than those with overlap. The results show also that the power coefficient increases with rising the aspect ratio (α. The conclusions from the measurements of the static torque for each rotor at different wind speeds verify the above summarized results of this work.

  2. Experimental study on fundamental performance of reverse flow diverters

    International Nuclear Information System (INIS)

    Fan Yanfang; Xu Cong; Jing Shan

    2008-01-01

    The Reverse Flow Diverter (RFD) is one of the key components affecting the liquid-delivered efficiency. The effects of inflow structure, outflow structure, area ratio and suction gap on the performance of RFDs were studied in this paper. It can be found experimentally that expected entrainment phenomenon can be achieved when the outlet velocity of fluid for RFDs' inflow structure is sufficient. There is less liquid delivered by an RFD with a long receiver than that without a receiver. Because of back-flow caused by vortex separation, oversize area ratio cannot have better entrainment phenomenon and the optimum area ratio is 1.5. When the ratio of suction gap length to inlet diameter of outflow structure is 0.9-1.0, the excellent liquid-delivered efficiency can be obtained. (authors)

  3. Evaluation of Sub Query Performance in SQL Server

    Science.gov (United States)

    Oktavia, Tanty; Sujarwo, Surya

    2014-03-01

    The paper explores several sub query methods used in a query and their impact on the query performance. The study uses experimental approach to evaluate the performance of each sub query methods combined with indexing strategy. The sub query methods consist of in, exists, relational operator and relational operator combined with top operator. The experimental shows that using relational operator combined with indexing strategy in sub query has greater performance compared with using same method without indexing strategy and also other methods. In summary, for application that emphasized on the performance of retrieving data from database, it better to use relational operator combined with indexing strategy. This study is done on Microsoft SQL Server 2012.

  4. Virginia power's human performance evaluation system (HPES)

    International Nuclear Information System (INIS)

    Patterson, W.E.

    1991-01-01

    This paper reports on the Human Performance Evaluation System (HPES) which was initially developed by the Institute of Nuclear Power Operations (INPO) using the Aviation Safety Reporting System (ASRS) as a guide. After a pilot program involving three utilities ended in 1983, the present day program was instituted. A methodology was developed, for specific application to nuclear power plant employees, to aid trained coordinators/evaluators in determining those factors that exert a negative influence on human behavior in the nuclear power plant environment. HPES is for anyone and everyone on site, from contractors to plant staff to plant management. No one is excluded from participation. Virginia Power's HPES program goal is to identify and correct the root causes of human performance problems. Evaluations are performed on reported real or perceived conditions that may have an adverse influence on members of the nuclear team. A report is provided to management identifying root cause and contributing factors along with recommended corrective actions

  5. An Experimental Study of FSO Link Performance in Desert Environment

    KAUST Repository

    Esmail, Maged; Fathallah, Habib; Alouini, Mohamed-Slim

    2016-01-01

    Free space optical (FSO) communication systems are affected by dust particles suspended in the atmosphere in arid and semi-arid regions. The presence of these particles in the air severely affects the optical link, reduces its availability and causes service outage. In the literature, the effect of dust on the microwave signals has been widely investigated. However, for FSO communication systems that exploit shorter wavelengths, information and research is still very limited yet almost inexistent. Therefore, in this paper, we investigate the performance of FSO links under dust storms. We designed a chamber to emulate this specific environment and carry out measurements. From the experimental investigations, we derive and propose an empirical model for the signal attenuation as a function of the visibility range. The results show acceptable performance for FSO links, under moderate and light dust, with potential reach distance of hundreds of meters to few kilometers. Furthermore, a comparison analysis shows that the dust induces 7 times higher attenuation than fog.

  6. An Experimental Study of FSO Link Performance in Desert Environment

    KAUST Repository

    Esmail, Maged

    2016-06-29

    Free space optical (FSO) communication systems are affected by dust particles suspended in the atmosphere in arid and semi-arid regions. The presence of these particles in the air severely affects the optical link, reduces its availability and causes service outage. In the literature, the effect of dust on the microwave signals has been widely investigated. However, for FSO communication systems that exploit shorter wavelengths, information and research is still very limited yet almost inexistent. Therefore, in this paper, we investigate the performance of FSO links under dust storms. We designed a chamber to emulate this specific environment and carry out measurements. From the experimental investigations, we derive and propose an empirical model for the signal attenuation as a function of the visibility range. The results show acceptable performance for FSO links, under moderate and light dust, with potential reach distance of hundreds of meters to few kilometers. Furthermore, a comparison analysis shows that the dust induces 7 times higher attenuation than fog.

  7. Experimental evaluation of flat plate solar collector using nanofluids

    International Nuclear Information System (INIS)

    Verma, Sujit Kumar; Tiwari, Arun Kumar; Chauhan, Durg Singh

    2017-01-01

    Highlights: • Solar collectors are special kind of heat exchangers. • Particle concentration is important parameter for thermal conductivity of nanofluid. • Rise of Bejan number indicates systems qualitative response. • Multi walled carbon nanotube is best performing. - Abstract: The present analysis focuses on a wide variety of nanofluids for evaluating performance of flat plate solar collector in terms of various parameters as well as in respect of energy and exergy efficiency. Also, based on our experimental findings on varying mass flow rate, the present investigation has been conducted with optimum particle volume concentration. Experiments indicate that for ∼0.75% particle volume concentration at a mass flow rate of 0.025 kg/s, exergy efficiency for Multi walled carbon nanotube/water nanofluid is enhanced by 29.32% followed by 21.46%, 16.67%, 10.86%, 6.97% and 5.74%, respectively for Graphene/water, Copper Oxide water, Aluminum Oxide/water, Titanium oxide/water, and Silicon Oxide/water respectively instead of water as the base fluid. Entropy generation, which is a drawback, is also minimum in Multiwalled carbon nanotube/water nanofluids. Under the same thermophysical parameters, the maximum drop in entropy generation can be observed in Multiwalled carbon nanotube/water, which is 65.55%, followed by 57.89%, 48.32%, 36.84%, 24.49% and 10.04%, respectively for graphene/water, copper oxide/water, Aluminum/water, Titanium Oxide /water, and Silicon oxide /water instead of water as the base fluid. Rise of Bejan number towards unity emphasizes improved system performance in terms of efficient conversion of the available energy into useful functions. The highest rise in energy efficiency of a collector has been recorded in Multiwalled carbon nanotube/water, which is 23.47%, followed by 16.97%, 12.64%, 8.28%, 5.09% and 4.08%, respectively for graphene/water, Copper oxide/water, Aluminum oxide/water, Titanium oxide /water, and Silicon oxide/water instead of

  8. Experimental hybrid evaluation of maize, for the Colombian Atlantic coast

    International Nuclear Information System (INIS)

    Urrea, R.; Navas Arboleda, A.A.; Mejia, S.; Ospina, J.G.

    1998-01-01

    To determine the yield potential and phenotypic stability four they were evaluated hybrid experimental simple and seven commercial witness of maize in eleven towns (L), during 1995 and 1996. The used experimental design was at random of complete blocks with four repetitions with parcels of four furrows of five m of longitude, distanced 0.90 m between furrows and 0.45 among blows (49 383 plts/ha) it Differ highly significant (smaller p 0.01) they were detected among genotype (G) and for the interaction G x L in the varieties yield. The analysis of stability of Eberhart and Russell (1966) it indicated that the genotypes had similar regression values; however, a clear tendency was observed to differentiate the behavior in yield of certain materials. The hybrid one experimental there are 76 and the commercial HR 661, they showed a good stability for yield

  9. Evaluating Nonclinical Performance of the Academic Pathologist

    Directory of Open Access Journals (Sweden)

    Austin Blackburn Wiles MD

    2018-02-01

    Full Text Available Academic pathologists perform clinical duties, as well as valuable nonclinical activities. Nonclinical activities may consist of research, teaching, and administrative management among many other important tasks. While clinical duties have many clear metrics to measure productivity, like the relative value units of Medicare reimbursement, nonclinical performance is often difficult to measure. Despite the difficulty of evaluating nonclinical activities, nonclinical productivity is used to determine promotion, funding, and inform professional evaluations of performance. In order to better evaluate the important nonclinical performance of academic pathologists, we present an evaluation system for leadership use. This system uses a Microsoft Excel workbook to provide academic pathologist respondents and reviewing leadership a transparent, easy-to-complete system that is both flexible and scalable. This system provides real-time feedback to academic pathologist respondents and a clear executive summary that allows for focused guidance of the respondent. This system may be adapted to fit practices of varying size, measure performance differently based on years of experience, and can work with many different institutional values.

  10. Evaluation of sucralfate enema in experimental diversion colitis

    Directory of Open Access Journals (Sweden)

    José Aires Pereira

    2013-10-01

    Full Text Available Diversion colitis (DC is an inflammatory disease that develops in segments with fecal di- version. Sucralfate (SCF complex, which consists of sucrose octasulfate and polyaluminum hydroxide, has been demonstrated to be effective in the treatment of different forms of colitis. However, until now, the effects of SCF have not been evaluated in DC. Objective: to evaluate whether the use of enemas containing SFC improves histological find- ings in experimental DC. Methods: Thirty-six rats underwent right colon bypass procedure through the creation of a proximal colostomy and a distal mucous fistula. The animals were divided into two groups according to the euthanization procedure to be performed two to four weeks after sur- gery. Each experimental group was divided into three subgroups of six animals, which were submitted to daily application of enemas containing saline solution 0.9% or SCF at con- centrations of 1.0 g/kg/day or 2.0 g/kg/day, respectively. The diagnosis of DC in segments with fecal diversion was established by histopathological study considering the following variables: epithelial loss, formation of crypt abscesses, the population of goblet cells, in- flammatory infiltrate and presence of fibrosis. For statistical analysis, the nonparametric Mann-Whitney and Kruskal-Wallis tests were used, with a significance level of 5% (p <0.05. Results: It was observed that the daily application of SCF enemas decreased epithelial loss, formation of colon crypt abscesses, inflammatory infiltrate and tissue fibrosis (p <0.05, un- related to time of intervention. The intervention with SCF preserves the goblet cell popula- tion. The effects of the substance on the preservation of colonic epithelium; the decrease in the inflammatory process and subsequent abscess formation in the colon crypts are associated with the concentration used, whereas tissue fibrosis decrease is associated with the concentration and time of intervention. Conclusion

  11. Methods of Evaluating Performances for Marketing Strategies

    OpenAIRE

    Ioan Cucu

    2005-01-01

    There are specific methods for assessing and improving the effectiveness of a marketing strategy. A marketer should state in the marketing plan what a marketing strategy is supposed to accomplish. These statements should set forth performance standards, which usually are stated in terms of profits, sales, or costs. Actual performance must be measured in similar terms so that comparisons are possible. This paper describes sales analysis and cost analysis, two general ways of evaluating the act...

  12. A Proposed RTN Officer Performance Evaluation System

    Science.gov (United States)

    1989-12-01

    Taa& No. WokI Unlit Acca ~def 11¶. TITLE (biclde Securiy ClassifiCation) A PROPOSED ROYAL THAI NAVY OFIICER PERFORM NCE EVALUATION SYSTEM 12. PERSONAL...all aspects of performance into account , the commanding officer uses his opinion to decide who is "the best." There are no standard guidelines for...ftequently used in orgunsadozn as a bais for adminiardstive decisions such as employee promotion., tuufer, and allocation of financial reward; employee

  13. Prospective safety performance evaluation on construction sites.

    Science.gov (United States)

    Wu, Xianguo; Liu, Qian; Zhang, Limao; Skibniewski, Miroslaw J; Wang, Yanhong

    2015-05-01

    This paper presents a systematic Structural Equation Modeling (SEM) based approach for Prospective Safety Performance Evaluation (PSPE) on construction sites, with causal relationships and interactions between enablers and the goals of PSPE taken into account. According to a sample of 450 valid questionnaire surveys from 30 Chinese construction enterprises, a SEM model with 26 items included for PSPE in the context of Chinese construction industry is established and then verified through the goodness-of-fit test. Three typical types of construction enterprises, namely the state-owned enterprise, private enterprise and Sino-foreign joint venture, are selected as samples to measure the level of safety performance given the enterprise scale, ownership and business strategy are different. Results provide a full understanding of safety performance practice in the construction industry, and indicate that the level of overall safety performance situation on working sites is rated at least a level of III (Fair) or above. This phenomenon can be explained that the construction industry has gradually matured with the norms, and construction enterprises should improve the level of safety performance as not to be eliminated from the government-led construction industry. The differences existing in the safety performance practice regarding different construction enterprise categories are compared and analyzed according to evaluation results. This research provides insights into cause-effect relationships among safety performance factors and goals, which, in turn, can facilitate the improvement of high safety performance in the construction industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Experimental determinations of the performances of heat transfer surfaces

    International Nuclear Information System (INIS)

    Pirovano, Alain; Viannay, Stephane; Mazeas, C.Y.

    1974-01-01

    With the help of flow schemes and of assumptions on the heat transfer, it is possible, in some cases, to predict the thermal and aerodynamical performances of a new heat transfer surface with moderate accuracy. These estimates, valid for an approximate classification of a new surface among known surfaces, are not accurate enough to be taken as a basis for the design of heat exchangers. In the present state of knowledge, the performances of a new heat transfer surface can only be determined accurately with experimental measurements. Bertin and Co have at their disposal two air test rigs especially designed for this purpose. The first one, more directly concerned with the measurements on tube bundles with fluid flow perpendicular to the generatrices of the tubes, is a semi-closed loop equipped with a high-efficiency ejector which amplifies the air flow rate supplied by an external source and thus allows high values of Reynolds number to be reached. The second one is adapted to other types of surfaces: tubes with external flow parallel to the generatrices, tubes with sophisticated cross section and with internal flow, compact surfaces with finned plates, etc. Both test rigs, the relevant equipment, the methods of data acquisition and of test results analysis are described in this paper. During the 5 past years, 60 configurations were tested. It was possible to compare some of the test results with the results of measurements performed later, on entire heat exchangers working with numbers of tubes, fluids, and temperature levels different from those prevailing during the tests on the small scale mock-up; the agreement is quite good [fr

  15. Experimental Analysis of DI Diesel Engine Performance with Blend Fuels of Oxygenated Additive and COME Biodiesel

    OpenAIRE

    P. Venkateswara Rao; B.V. Appa Rao; D. Radhakrishna

    2012-01-01

    An experimental investigation was carried out to evaluate the effect of using Triacetin (T) as an additive with biodiesel on direct injection diesel engine for performance and combustion characteristics. Normally in the usage of diesel fuel and neat biodiesel, knocking can be detected to some extent. By adding triacetin [C9H14O6] additive to biodiesel, this problem can be alleviated to some extent and the tail pipe emissions are reduced. Comparative study was conducted using petro-diesel, bio...

  16. Subjective performance evaluations and employee careers

    DEFF Research Database (Denmark)

    Frederiksen, Anders; Lange, Fabian; Kriechell, Ben

    Firms commonly use supervisor evaluations to assess the performance of employees who work in complex environments. Doubts persist whether their subjective nature invalidates using these performance measures to learn about careers of individuals and to inform theory in personnel economics. We...... examine personnel data from six large companies and establish how subjective ratings, interpreted as ordinal rankings of employee performances within narrowly defined peer-groups, correlate with objective career outcomes. We find many similarities across firms in how subjective ratings correlate with base...

  17. Development and Performance Evaluation of Indigenously Made ...

    African Journals Online (AJOL)

    A study was conducted to develop, construct and evaluate the performance of cooling chambers made from factory pressed burnt clay (structure-1), locally molded mud blocks (structure-2) and wood wall (structure-3) for extending the shelf life of mangoes and sweet oranges. It was observed that structure-1 significantly ...

  18. Subjective performance evaluation and gender discrimination

    NARCIS (Netherlands)

    Maas, V.S.; Torres-Gonzalez, R.

    2011-01-01

    Gender discrimination continues to be a problem in organizations. It is therefore important that organizations use performance evaluation methods that ensure equal opportunities for men and women. This article reports the results of an experiment to investigate whether and, if so, how the gender of

  19. Technique of experimental evaluation of cloud environment attacks detection accuracy

    Directory of Open Access Journals (Sweden)

    Sergey A. Klimachev

    2018-05-01

    Full Text Available The article is devoted to research of efficiency evaluation of IDS used for dynamic and complex organizational and technical structure computing platform guard. The components of the platform have a set of heterogeneous parameters. Analysis of existing IDS evaluation technique revealed shortcomings in justification of quantitative metrics that describe the efficiency and reliability IDS resolving. This makes if difficult to prove IDS evaluation technique. The purpose of the study is to increase IDS evaluation objectivity. To achive the purpose it is necessary to develop the correct technique, tools, experimental stand. The article proposes the results of development and approbation of the technique of IDS efficiency evaluation and software for it. The technique is based on defining of optimal set of attack detection accuracy scores. The technique and the software allow solving problems of comparative analysis of IDS that have similar functionality. As a result of the research, a number of task have been solved, including the selection of universal quantitative metrics for attack detection accuracy evaluation, the defining of summarised attack detection accuracy evaluation metric based on defining of pareto-optimal set of scores that ensure the confidentiality, integrity and accessibility of cloud environment information and information resources,  the development of a functional model,  a functional scheme and a software for cloud environment IDS research.

  20. Behavioral patterns of environmental performance evaluation programs.

    Science.gov (United States)

    Li, Wanxin; Mauerhofer, Volker

    2016-11-01

    During the past decades numerous environmental performance evaluation programs have been developed and implemented on different geographic scales. This paper develops a taxonomy of environmental management behavioral patterns in order to provide a practical comparison tool for environmental performance evaluation programs. Ten such programs purposively selected are mapped against the identified four behavioral patterns in the form of diagnosis, negotiation, learning, and socialization and learning. Overall, we found that schemes which serve to diagnose environmental abnormalities are mainly externally imposed and have been developed as a result of technical debates concerning data sources, methodology and ranking criteria. Learning oriented scheme is featured by processes through which free exchange of ideas, mutual and adaptive learning can occur. Scheme developed by higher authority for influencing behaviors of lower levels of government has been adopted by the evaluated to signal their excellent environmental performance. The socializing and learning classified evaluation schemes have incorporated dialogue, participation, and capacity building in program design. In conclusion we consider the 'fitness for purpose' of the various schemes, the merits of our analytical model and the future possibilities of fostering capacity building in the realm of wicked environmental challenges. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Performance Evaluation of Investment (Mutual Funds

    Directory of Open Access Journals (Sweden)

    Povilas Vyšniauskas

    2014-12-01

    Full Text Available The efficiency of an investment fund is one of the main components in evaluating the performance of the fund. This study seeks for introducing and comparing risk and performance evaluation ratios. The paper is aimed at testing the worked out ratios and at distinguishing between the best ones for the purpose of evaluating the performance of Lithuanian mutual funds. Scientific studies show that a standard deviation, alpha, beta, Sharpe and Treynor ratios are mostly employed for identifying the performance of mutual funds that are also compared with their benchmark index to establish if these funds are outperformed and if is it worth paying management fees to investment banks for managing mutual funds. Historical data were selected for the period from 2012-01-02 to 2013-10-15 analysing the prices of monthly funds. The paper points out the areas of a practical application of the proposed model for investment fund valuation, which may not only provide valuable outcomes for practitioners but also may inspire further research on this article.

  2. Performance evaluation soil samples utilizing encapsulation technology

    Science.gov (United States)

    Dahlgran, James R.

    1999-01-01

    Performance evaluation soil samples and method of their preparation using encapsulation technology to encapsulate analytes which are introduced into a soil matrix for analysis and evaluation by analytical laboratories. Target analytes are mixed in an appropriate solvent at predetermined concentrations. The mixture is emulsified in a solution of polymeric film forming material. The emulsified solution is polymerized to form microcapsules. The microcapsules are recovered, quantitated and introduced into a soil matrix in a predetermined ratio to form soil samples with the desired analyte concentration.

  3. Numerical and experimental evaluation of masonry prisms by finite element method

    Directory of Open Access Journals (Sweden)

    C. F.R. SANTOS

    Full Text Available Abstract This work developed experimental tests and numerical models able to represent the mechanical behavior of prisms made of ordinary and high strength concrete blocks. Experimental tests of prisms were performed and a detailed micro-modeling strategy was adopted for numerical analysis. In this modeling technique, each material (block and mortar was represented by its own mechanical properties. The validation of numerical models was based on experimental results. It was found that the obtained numerical values of compressive strength and modulus of elasticity differ by 5% from the experimentally observed values. Moreover, mechanisms responsible for the rupture of the prisms were evaluated and compared to the behaviors observed in the tests and those described in the literature. Through experimental results it is possible to conclude that the numerical models have been able to represent both the mechanical properties and the mechanisms responsible for failure.

  4. Analytical Performance Evaluation of Different Switch Solutions

    Directory of Open Access Journals (Sweden)

    Francisco Sans

    2013-01-01

    Full Text Available The virtualization of the network access layer has opened new doors in how we perceive networks. With this virtualization of the network, it is possible to transform a regular PC with several network interface cards into a switch. PC-based switches are becoming an alternative to off-the-shelf switches, since they are cheaper. For this reason, it is important to evaluate the performance of PC-based switches. In this paper, we present a performance evaluation of two PC-based switches, using Open vSwitch and LiSA, and compare their performance with an off-the-shelf Cisco switch. The RTT, throughput, and fairness for UDP are measured for both Ethernet and Fast Ethernet technologies. From this research, we can conclude that the Cisco switch presents the best performance, and both PC-based switches have similar performance. Between Open vSwitch and LiSA, Open vSwitch represents a better choice since it has more features and is currently actively developed.

  5. Performance Evaluation Methods for Assistive Robotic Technology

    Science.gov (United States)

    Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.

    Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.

  6. Experimental evaluation of the primary damage process: neutron energy effects

    Energy Technology Data Exchange (ETDEWEB)

    Goland, A.N.

    1979-01-01

    Experimental evaluation of the neutron energy dependnece of the primary damage stage depends upon a number of theoretical concepts. This state can only be observed after low- or perhaps ambient-temperature, low-fluence irradiations. The primary recoil energy spectrum, which determines the character of the displacement cascades, can be calculated if dosimetry has provided an accurate neutron spectrum. A review of experimental results relating neutron-energy effects shows that damage energy or damage energy cross section has often been a reliable correlation parameter for primary damage state experiments. However, the forthcoming emphasis on higher irradiation temperatures, more complex alloys and microstructural evolution has fostered a search for additional meaningful correlation parameters.

  7. Antioxidative Categorization of Twenty Amino Acids Based on Experimental Evaluation.

    Science.gov (United States)

    Xu, Naijin; Chen, Guanqun; Liu, Hui

    2017-11-27

    In view of the great importance bestowed on amino acids as antioxidants in oxidation resistance, we attempted two common redox titration methods in this report, including micro-potassium permanganate titration and iodometric titration, to measure the antioxidative capacity of 20 amino acids, which are the construction units of proteins in living organisms. Based on the relative intensities of the antioxidative capacity, we further conducted a quantitative comparison and found out that the product of experimental values obtained from the two methods was proven to be a better indicator for evaluating the relative antioxidative capacity of amino acids. The experimental results were largely in accordance with structural analysis made on amino acids. On the whole, the 20 amino acids concerned could be divided into two categories according to their antioxidative capacity. Seven amino acids, including tryptophan, methionine, histidine, lysine, cysteine, arginine and tyrosine, were greater in total antioxidative capacity compared with the other 13 amino acids.

  8. Geothermal source heat pump performance for a greenhouse heating system: an experimental study

    Directory of Open Access Journals (Sweden)

    Alexandros Sotirios Anifantis

    2016-09-01

    Full Text Available Greenhouses play a significant function in the modern agriculture economy even if require great amount of energy for heating systems. An interesting solution to alleviate the energy costs and environmental problems may be represented by the use of geothermal energy. The aim of this paper, based on measured experimental data, such as the inside greenhouse temperature and the heat pump performance (input and output temperatures of the working fluid, electric consumption, was the evaluation of the suitability of low enthalpy geothermal heat sources for agricultural needs such as greenhouses heating. The study was carried out at the experimental farm of the University of Bari, where a greenhouse was arranged with a heating system connected to a ground-source heat pump (GSHP, which had to cover the thermal energy request. The experimental results of this survey highlight the capability of the geothermal heat source to ensue thermal conditions suitable for cultivation in greenhouses even if the compressor inside the heat pump have operated continuously in a fluctuating state without ever reaching the steady condition. Probably, to increase the performance of the heat pump and then its coefficient of performance within GSHP systems for heating greenhouses, it is important to analyse and maximise the power conductivity of the greenhouse heating system, before to design an expensive borehole ground exchanger. Nevertheless, according to the experimental data obtained, the GSHP systems are effective, efficient and environmental friendly and may be useful to supply the heating energy demand of greenhouses.

  9. The development of human factors experimental evaluation techniques -The development of human factors technologies-

    International Nuclear Information System (INIS)

    Sim, Bong Shick; Oh, In Seok; Cha, Kyeong Ho; Lee, Hyun Chul

    1994-04-01

    In the 2nd year of the research project for the development of human factors evaluation techniques, we first defined the experimental target systems by the comparison study of the advanced control rooms proposed by foreign countries in order to make the experiment feasible and realistic for the 10 experimental items selected in the first year of the project. Then we have decided to confine our research on the big board overview panel and operator workstations. Following the development of selection criteria for our research interest, we have identified the design variables which may influence the performance of the operator by the functional analysis. The experimental variables which will be used for the evaluation of the proposed items are then defined by the relational analysis between evaluation items and design variables and they are classified by the characteristics of the measurement data. The functional requirements of ITF are developed to accommodate the necessary functions for carrying out the 10 evaluation items. The functional requirements for each sub-system of ITF have been developed with the experimental paradigm of APTEA. Finally we have reviewed the compact nuclear simulator (CNS) at KAERI from the point of view of jyman factors guidelines/principles and proposed the two possible layouts for the experimental apparatus for the evaluation of display alternative and operational procedure. (Author)

  10. Experimental evaluation of coating delamination in vinyl coated metal forming

    International Nuclear Information System (INIS)

    Son, Young Ki; Lee, Chan Joo; Kim, Byung Min; Lee, Jung Min; Byoen, Sang Doek; Lee, Soen Bong

    2012-01-01

    In this paper, a new evaluation and prediction method for coating delamination during sheet metal forming is presented. On the basis of the forming limit diagram (FLD), the current study evaluates the delamination of PET coating by using a cross cut specimen, dome test, and rectangular cup drawing test. Dome test specimens were subjected to biaxial, plane strain, and uniaxial deformation modes. Rectangular cup drawing test specimens were subjected to the deep drawing deformation mode, and compression deformation mode. A vinyl coated metal (VCM) sheet consists of three layers of polymer on the sheet metals: a protective film, a PET layer and a PVC layer. The areas with coating delamination were identified, and the results of the evaluation were plotted according to major and minor strain values, depicting coating delamination. The constructed delamination limit diagram (DLD) can be used to determine the forming limit of VCM during the complex press forming process. ARGUS (GOM) was employed to identify the strain value and deformation mode of the delaminated surface after the press forming. After identifying the areas of delamination, the DLD of the PET coating can be constructed in a format similar to that of the FLD. The forming limit of the VCM sheet can be evaluated using the superimposition of the delamination limit strain of the coating onto the FLD of VCM sheet. The experimental results showed that the proposed test method will support the sheet metal forming process design for VCM sheets. The assessment method presented in this study can be used to determine the delamination limit strain under plastic deformation of other polymer coated metals. The experimental results suggested that the proposed testing method is effective in evaluating delamination for specific applications

  11. Experimental evaluation of coating delamination in vinyl coated metal forming

    Energy Technology Data Exchange (ETDEWEB)

    Son, Young Ki; Lee, Chan Joo; Kim, Byung Min [Pusan National Univ., Busan (Korea, Republic of); Lee, Jung Min [Korea Institute of Industrial Technology, Busan (Korea, Republic of); Byoen, Sang Doek [HA Digital Engineering Gr., Seongsan Gu (Korea, Republic of); Lee, Soen Bong [Keimyung Univ., Daegu (Korea, Republic of)

    2012-10-15

    In this paper, a new evaluation and prediction method for coating delamination during sheet metal forming is presented. On the basis of the forming limit diagram (FLD), the current study evaluates the delamination of PET coating by using a cross cut specimen, dome test, and rectangular cup drawing test. Dome test specimens were subjected to biaxial, plane strain, and uniaxial deformation modes. Rectangular cup drawing test specimens were subjected to the deep drawing deformation mode, and compression deformation mode. A vinyl coated metal (VCM) sheet consists of three layers of polymer on the sheet metals: a protective film, a PET layer and a PVC layer. The areas with coating delamination were identified, and the results of the evaluation were plotted according to major and minor strain values, depicting coating delamination. The constructed delamination limit diagram (DLD) can be used to determine the forming limit of VCM during the complex press forming process. ARGUS (GOM) was employed to identify the strain value and deformation mode of the delaminated surface after the press forming. After identifying the areas of delamination, the DLD of the PET coating can be constructed in a format similar to that of the FLD. The forming limit of the VCM sheet can be evaluated using the superimposition of the delamination limit strain of the coating onto the FLD of VCM sheet. The experimental results showed that the proposed test method will support the sheet metal forming process design for VCM sheets. The assessment method presented in this study can be used to determine the delamination limit strain under plastic deformation of other polymer coated metals. The experimental results suggested that the proposed testing method is effective in evaluating delamination for specific applications.

  12. Conceptual Designs for the Performance Improvement of APR1400 SIT and Preliminary Performance Evaluation

    International Nuclear Information System (INIS)

    Chu, In-Cheol; Kwon, Tae-Soon; Song, Chul-Hwa

    2008-01-01

    Some evolutionary type PWRs such as APR1400 and APWR adopt advanced safety injection tank (SIT). The SIT of APR1400 has a fluidic device (FD) which passively controls ECC water injection flow rate into reactor coolant system during refill and reflood phases of LB-LOCA (i.e., a high injection flow rate during the refill phase and a low injection flow rate during the reflood phase). The benefit of the FD is the elimination of the function of low pressure safety injection pump from the safety injection system. The flow controlling performance of the APR1400 FD was evaluated using a prototypical full-scale test facility, called VAPER (Valve Performance Evaluation Rig). Even though the performance of the APR1400 FD satisfied major design and licensing requirements, further improvement of the performance is expected such as the extension of total injection period, the delay of nitrogen gas discharge. Several conceptual designs have been being drawn out in order to improve the performance of the APR1400 SIT. The performance of some designs was evaluated using a small scale SIT test rig. The present paper introduces some of the conceptual designs and shows the performance evaluation experimental results

  13. Strategic performance evaluation in cancer centers.

    Science.gov (United States)

    Delgado, Rigoberto I; Langabeer, James R

    2009-01-01

    Most research in healthcare strategy has focused on formulating or implementing organizational plans and strategies, and little attention has been dedicated to the post-implementation control and evaluation of strategy, which we contend is the most critical aspect of achieving organizational goals. The objective of this study was to identify strategic control approaches used by major cancer centers in the country and to relate these practices to financial performance. Our intent was to expand the theory and practice of healthcare strategy to focused services, such as oncology. We designed a 17-question survey to capture elements of strategy and performance from our study sample, which comprised major cancer hospitals in the United States and shared similar mandates and resource constraints. The results suggest that high-performing cancer centers use more sophisticated analytical approaches, invest greater financial resources in performance analysis, and conduct more frequent performance reviews than do low-performing organizations. Our conclusions point to the need for a more robust approach to strategic assessment. In this article, we offer a number of recommendations for management to achieve strategic plans and goals on the basis of our research. To our knowledge, this study is one of the first to concentrate on the area of strategic control.

  14. Evaluating the Performance of Rijndael Encryption

    Directory of Open Access Journals (Sweden)

    Bogdan CIOBANU

    2012-01-01

    Full Text Available In this paper we present a a comparative analysis of the performance of the Rijndael algorithm, developed with the help of two programming languages, namely C and Matlab. The main goal is to get a full, detailed picture about the functioning of this algorithm. In order to evaluate the performances of the Rijndael algorithm for the two different implementations, we took into account establishing the variable factors within each type of implementation so as to avoid the reasons that might lead to running differences (for instance, the comparison of the two implementations will be performed for the situation in which the encryption key length is the same. We chose to use the traditional algorithm for both types of implementation, in which the input is transformed into 4 blocks of 4 bytes, followed by the handling of each byte from each individual column

  15. Experimental evaluation of human-system interaction on alarm design

    International Nuclear Information System (INIS)

    Huang, F.-H.; Lee, Y.-L.; Hwang, S.-L.; Yenn, T.-C.; Yu, Y.-C.; Hsu, C.-C.; Huang, H.-W.

    2007-01-01

    This study evaluates the practicability of automatic reset alarm system in Fourth Nuclear Power Plant (FNPP) of Taiwan. The features of auto-reset alarm system include dynamic prioritization of all alarm signals and fast system reset. Two experiments were conducted to evaluate the effect of automatic/manual reset on operation time, situational awareness (SA), task load index (TLX), and subjective ratings. All participants, including Experts and Novices, took part in the experiment on the alarm system simulator with Load Rejection procedure. The experimental results imply that the auto-reset alarm system may be applied in an advanced control room under Load Rejection procedure, because all participants' operation time were reduced as well as Novice's SA were raised up. Nevertheless, to ensure operating safety in FNPP, the effects of the auto-reset alarm system in other procedures/special situations still need to be tested in the near future

  16. Performance Evaluation of the RSG-GAS Micronomad MCA

    International Nuclear Information System (INIS)

    Badriyana, B.; Pujijanto, M.S.

    2000-01-01

    The MicroNOMAD-MCA is a gamma spectrometer for radiation exposure measurement using matrix respond method. The equipment used NAI detector to produced pulse spectrum and then covert to quantities of dosimeter by a computer program. Performance evaluation of the MCA-MicroNOMAD has been done to evaluate the reliability and accuracy of the measurement result. The evaluation was done by comparison test with standard survey meter. Measurement of gamma radiation was performed in the experimental Hall, Operation Hall of the RSG-GAS and outside of reactor building with 15 MW reactor power. The gamma radiation exposure measurement result in the Experimental Hall using the MicroNOMAD MCA and Ion Chamber survey meter are 92,4 x 10 exp 6 rad/hour and (62 ∼ 88) x 10 exp 6 rad/hour, respectively. The gamma radiation exposure in the Operation Hall using the MicroNOMAD MCA and Ion Chamber are 165,4 x 10 exp 6 rad/hour and (167 ∼ 194) x 10 exp 6 rad/hour, respectively. By means of this result it can concluded that the reading error of the MicroNOMAD MCA with standard survey meter is small enough. Beside the point the MicroNOMAD MCA has a good performance for gamma radiation measurement in the energy range of 0,2 - 9 MeV

  17. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis

  18. Experimental (Network) and Evaluated Nuclear Reaction Data at NDS

    International Nuclear Information System (INIS)

    Otsuka, N.; Semkova, V.; Simakov, S.P.; Zerkin, V.

    2011-01-01

    Dr Simakov of Nuclear Data Services Unit in the Nuclear Data Section (NDS) gave a brief overview of the data compilation and evaluation activities in the nuclear data community: experimental nuclear reaction data (EXFOR, http://www-nds.iaea.org/exfor/) and evaluated nuclear reaction data (ENDF, http://www-nds.iaea.org/endf). The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by NDS includes 14 Centres in 8 Countries (China, Hungary, India, Japan, Korea, Russian, Ukraine, USA) and 2 International Organizations (NEA, IAEA). It had the first meeting of four core centres (Brookhaven, Saclay, Obninsk, Vienna) in 1966 and the EXFOR was adopted as an official data exchange format. In 2000, IAEA implemented the EXFOR database as a relational multiform database and the EXFOR is a trusted, increasing and living database with 19100 experimental works (as of September 2011) and 141600 data tables. The EXFOR provides a compilation control system for selection of articles and compilation of data and the NRDC home page provides manuals, documents and codes. The nuclear data can be retrieved by the web-retrieval system or distributed on a DVD on request. The EXFOR data play a critical role in the development of evaluated nuclear reaction data. There are several major general purpose libraries: ENDF (US), CENDL (China), JEFF (EU), JENDL (Japan) and RUSFOND (Russia). In addition, there are special libraries for particular applications: EAF (European Activation File), FENDL (Fusion Evaluated Nuclear Data Library for ITER neutronics), IBANDL (Ion Beam Analysis Nuclear Data Library for surface analysis of solids), IRDF, DXS (Dosimetry, radiation damage and gas production data) and Medical portal. Dr V. Zerkin of NDS demonstrated the data retrieval from the EXFOR database and the ENDF library.

  19. Experimental (Network) and Evaluated Nuclear Reaction Data at NDS

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, N; Semkova, V; Simakov, S P; Zerkin, V [Nuclear Data Services Unit, Nuclear Data Section, IAEA, Vienna (Austria)

    2011-11-15

    Dr Simakov of Nuclear Data Services Unit in the Nuclear Data Section (NDS) gave a brief overview of the data compilation and evaluation activities in the nuclear data community: experimental nuclear reaction data (EXFOR, http://www-nds.iaea.org/exfor/) and evaluated nuclear reaction data (ENDF, http://www-nds.iaea.org/endf). The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by NDS includes 14 Centres in 8 Countries (China, Hungary, India, Japan, Korea, Russian, Ukraine, USA) and 2 International Organizations (NEA, IAEA). It had the first meeting of four core centres (Brookhaven, Saclay, Obninsk, Vienna) in 1966 and the EXFOR was adopted as an official data exchange format. In 2000, IAEA implemented the EXFOR database as a relational multiform database and the EXFOR is a trusted, increasing and living database with 19100 experimental works (as of September 2011) and 141600 data tables. The EXFOR provides a compilation control system for selection of articles and compilation of data and the NRDC home page provides manuals, documents and codes. The nuclear data can be retrieved by the web-retrieval system or distributed on a DVD on request. The EXFOR data play a critical role in the development of evaluated nuclear reaction data. There are several major general purpose libraries: ENDF (US), CENDL (China), JEFF (EU), JENDL (Japan) and RUSFOND (Russia). In addition, there are special libraries for particular applications: EAF (European Activation File), FENDL (Fusion Evaluated Nuclear Data Library for ITER neutronics), IBANDL (Ion Beam Analysis Nuclear Data Library for surface analysis of solids), IRDF, DXS (Dosimetry, radiation damage and gas production data) and Medical portal. Dr V. Zerkin of NDS demonstrated the data retrieval from the EXFOR database and the ENDF library.

  20. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De [Chonnam Univ. Medical School, Kwangju (Korea, Republic of)

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis.

  1. Experimental investigation on the hydrodynamic performance of a wave energy converter

    Science.gov (United States)

    Zheng, Xiong-bo; Ma, Yong; Zhang, Liang; Jiang, Jin; Liu, Heng-xu

    2017-06-01

    Wave energy is an important type of marine renewable energy. A wave energy converter (WEC) moored with two floating bodies was developed in the present study. To analyze the dynamic performance of the WEC, an experimental device was designed and tested in a tank. The experiment focused on the factors which impact the motion and energy conversion performance of the WEC. Dynamic performance was evaluated by the relative displacements and velocities of the oscillator and carrier which served as the floating bodies of WEC. Four factors were tested, i.e. wave height, wave period, power take-off (PTO) damping, and mass ratio ( R M) of the oscillator and carrier. Experimental results show that these factors greatly affect the energy conversion performance, especially when the wave period matches R M and PTO damping. According to the results, we conclude that: (a) the maximization of the relative displacements and velocities leads to the maximization of the energy conversion efficiency; (b) the larger the wave height, the higher the energy conversion efficiency will be; (c) the relationships of energy conversion efficiency with wave period, PTO damping, and R M are nonlinear, but the maximum efficiency is obtained when these three factors are optimally matched. Experimental results demonstrated that the energy conversion efficiency reached the peak at 28.62% when the wave height was 120 mm, wave period was 1.0 s, R M was 0.21, and the PTO damping was corresponding to the resistance of 100 Ω.

  2. A performance evaluation of personnel identity verifiers

    International Nuclear Information System (INIS)

    Maxwell, R.L.; Wright, L.J.

    1987-01-01

    Personnel identity verification devices, which are based on the examination and assessment of a body feature or a unique repeatable personal action, are steadily improving. These biometric devices are becoming more practical with respect to accuracy, speed, user compatibility, reliability and cost, but more development is necessary to satisfy the varied and sometimes ill-defined future requirements of the security industry. In an attempt to maintain an awareness of the availability and the capabilities of identity verifiers for the DOE security community, Sandia Laboratories continues to comparatively evaluate the capabilities and improvements of developing devices. An evaluation of several recently available verifiers is discussed in this paper. Operating environments and procedures more typical of physical access control use can reveal performance substantially different from the basic laboratory tests

  3. An Experimental Study of Cutting Performances of Worn Picks

    Science.gov (United States)

    Dogruoz, Cihan; Bolukbasi, Naci; Rostami, Jamal; Acar, Cemil

    2016-01-01

    The best means to assess rock cuttability and efficiency of cutting process for using mechanical excavation is specific energy (SE), measured in full-scale rock cutting test. This is especially true for the application of roadheaders, often fitted with drag-type cutting tools. Radial picks or drag bits are changed during the operation as they reach a certain amount of wear and become blunt. In this study, full-scale cutting tests in different sedimentary rock types with bits having various degree of wear were used to evaluate the influence of bit wear on cutting forces and specific energy. The relationship between the amount of wear as represented by the size of the wear flats at the tip of the bit, and cutting forces as well as specific energy was examined. The influence of various rock properties such as mineral content, uniaxial compressive strength, tensile strength, indentation index, shore hardness, Schmidt hammer hardness, and density with required SE of cutting using different levels of tool wear was also studied. The preliminary analysis of the data shows that the mean cutting forces increase 2-3 times and SE by 4-5 times when cutting with 4 mm wear flat as compared to cutting with new or sharp wedge shape bits. The grain size distribution of the muck for cutting different rock types and different level of bit wear was analyzed and discussed. The best fit prediction models for SE based on statistical analysis of laboratory test results are introduced. The model can be used for estimating the performance of mechanical excavators using radial tools, especially roadheaders, continuous miners and longwall drum shearers.

  4. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  5. Evaluating the ergonomics of BCI devices for research and experimentation.

    Science.gov (United States)

    Ekandem, Joshua I; Davis, Timothy A; Alvarez, Ignacio; James, Melva T; Gilbert, Juan E

    2012-01-01

    The use of brain computer interface (BCI) devices in research and applications has exploded in recent years. Applications such as lie detectors that use functional magnetic resonance imaging (fMRI) to video games controlled using electroencephalography (EEG) are currently in use. These developments, coupled with the emergence of inexpensive commercial BCI headsets, such as the Emotiv EPOC ( http://emotiv.com/index.php ) and the Neurosky MindWave, have also highlighted the need of performing basic ergonomics research since such devices have usability issues, such as comfort during prolonged use, and reduced performance for individuals with common physical attributes, such as long or coarse hair. This paper examines the feasibility of using consumer BCIs in scientific research. In particular, we compare user comfort, experiment preparation time, signal reliability and ease of use in light of individual differences among subjects for two commercially available hardware devices, the Emotiv EPOC and the Neurosky MindWave. Based on these results, we suggest some basic considerations for selecting a commercial BCI for research and experimentation. STATEMENT OF RELEVANCE: Despite increased usage, few studies have examined the usability of commercial BCI hardware. This study assesses usability and experimentation factors of two commercial BCI models, for the purpose of creating basic guidelines for increased usability. Finding that more sensors can be less comfortable and accurate than devices with fewer sensors.

  6. Evaluation of the Service Performance of Ships

    DEFF Research Database (Denmark)

    Andersen, Poul; Borrod, Anne-Sophie; Blanchot, Hervé

    2005-01-01

    A simple method has been established for the evaluation of the service performance of ships. Input data are easily collected daily on board and transformed to a well-defined condition that makes possible the comparison between ships, for instance, sister ships, and between different time periods...... of voyages for the same ship. The procedure has been applied to two ships that are identical, with the exception that one has a conventional propeller, whereas the other one is fitted with a high-efficiency propeller of the KAPPEL type. The results are obtained from a period of 2 years steaming for both...

  7. Performance evaluation of computer and communication systems

    CERN Document Server

    Le Boudec, Jean-Yves

    2011-01-01

    … written by a scientist successful in performance evaluation, it is based on his experience and provides many ideas not only to laymen entering the field, but also to practitioners looking for inspiration. The work can be read systematically as a textbook on how to model and test the derived hypotheses on the basis of simulations. Also, separate parts can be studied, as the chapters are self-contained. … the book can be successfully used either for self-study or as a supplementary book for a lecture. I believe that different types of readers will like it: practicing engineers and resea

  8. Performance evaluation on vibration control of MR landing gear

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D Y; Nam, Y J; Park, M K [Graduate School, Pusan National University, Busan 609-735 (Korea, Republic of); Yamane, R [Kokushikan University, 4-28-1 Setagaya, Setagaya-ku, Tokyo 154-8515 (Japan)], E-mail: ldy5577@yahoo.co.kr, E-mail: mkpark1@pusan.ac.kr

    2009-02-01

    This paper is concerned with the applicability of the developed MR damper to the landing gear system for the attenuating undesired shock and vibration in the landing and taxing phases. First of all, the experimental model of the MR damper is derived based on the results of performance evaluations. Next, a simplified skyhook controller, which is one of the most straightforward, but effective approaches for improving ride comport in vehicles with active suspensions, is formulated. Then, the vibration control performances of the landing gear system using the MR damper are theoretically evaluated in the landing phase of the aircraft. A series of simulation analyses show that the proposed MR damper with the skyhook controller is effective for suppressing undesired vibration of the aircraft body. Finally, the effectiveness of the simulation results are additionally verified via HILS (Hardware-in-the-loop-simulation) method.

  9. Performance evaluation of emerging JPEGXR compression standard for medical images

    International Nuclear Information System (INIS)

    Basit, M.A.

    2012-01-01

    Medical images require loss less compression as a small error due to lossy compression may be considered as a diagnostic error. JPEG XR is the latest image compression standard designed for variety of applications and has a support for lossy and loss less modes. This paper provides in-depth performance evaluation of latest JPEGXR with existing image coding standards for medical images using loss less compression. Various medical images are used for evaluation and ten images of each organ are tested. Performance of JPEGXR is compared with JPEG2000 and JPEGLS using mean square error, peak signal to noise ratio, mean absolute error and structural similarity index. JPEGXR shows improvement of 20.73 dB and 5.98 dB over JPEGLS and JPEG2000 respectively for various test images used in experimentation. (author)

  10. Evaluating cryostat performance for naval applications

    Science.gov (United States)

    Knoll, David; Willen, Dag; Fesmire, James; Johnson, Wesley; Smith, Jonathan; Meneghelli, Barry; Demko, Jonathan; George, Daniel; Fowler, Brian; Huber, Patti

    2012-06-01

    The Navy intends to use High Temperature Superconducting Degaussing (HTSDG) coil systems on future Navy platforms. The Navy Metalworking Center (NMC) is leading a team that is addressing cryostat configuration and manufacturing issues associated with fabricating long lengths of flexible, vacuum-jacketed cryostats that meet Navy shipboard performance requirements. The project includes provisions to evaluate the reliability performance, as well as proofing of fabrication techniques. Navy cryostat performance specifications include less than 1 Wm-1 heat loss, 2 MPa working pressure, and a 25-year vacuum life. Cryostat multilayer insulation (MLI) systems developed on the project have been validated using a standardized cryogenic test facility and implemented on 5-meterlong test samples. Performance data from these test samples, which were characterized using both LN2 boiloff and flow-through measurement techniques, will be presented. NMC is working with an Integrated Project Team consisting of Naval Sea Systems Command, Naval Surface Warfare Center-Carderock Division, Southwire Company, nkt cables, Oak Ridge National Laboratory (ORNL), ASRC Aerospace, and NASA Kennedy Space Center (NASA-KSC) to complete these efforts. Approved for public release; distribution is unlimited. This material is submitted with the understanding that right of reproduction for governmental purposes is reserved for the Office of Naval Research, Arlington, Virginia 22203-1995.

  11. Monitoring and Evaluating Government Performance in Botswana

    Directory of Open Access Journals (Sweden)

    E. K. Botlhale

    2015-03-01

    Full Text Available In an era characterised by fiscal stress in the post-global recession era, clichés such as ‘bang for the buck’ are commonplace. Governments are under increasing pressure to spend limited public resources in efficient and  effective ways. Efficient and  effective governments are a necessary, though not sufficient, condition for economic development. Hence, governments have adopted performance-improving interventions such as New Public Management. Botswana jumped into the bandwagon of public sector reforms in the 1990s through interventions such as Performance-based Management Systems. The focus was almost entirely on performance enhancement to the neglect of performance measurement through a result-based Monitoring and Evaluation (M&E framework. However, in 2009, the government decided to mainstream M&E into the development planning regime. Since the M&E tool is still in draft form, Botswana is very favourably circumstanced to learn from others. Meanwhile essentials to do are: attitudinal change, shared vision on M&E, stakeholder management and demand and use of M&E information by policy-makers such as Members of Parliament.

  12. Performance evaluations of a geothermal power plant

    International Nuclear Information System (INIS)

    Coskun, C.; Oktay, Z.; Dincer, I.

    2011-01-01

    Thermodynamic analysis of an operational 7.5 MWe binary geothermal power plant in Tuzla-Turkey is performed, through energy and exergy, using actual plant data to assess its energetic and exergetic performances. Eight performance-related parameters, namely total exergy destruction ratio, component exergy destruction ratio, dimensionless exergy destruction, energetic renewability ratio, exergetic renewability ratio, energetic reinjection ratio, exergetic reinjection ratio and improvement potential are investigated. Energy and exergy losses/destructions for the plant and its units are determined and illustrated using energy and exergy flow diagrams. The largest energy and exergy losses occur in brine reinjection unit. The variation of the plant energy efficiency is found between 6% and 12%. Exergy efficiency values change between 35 and 49%. The annual average energy and exergy efficiencies are found as 9.47% and 45.2%, respectively. - Highlights: → Investigation of a geothermal system energetically and exergetically. → Performance assessment of the system through energy and exergy efficiencies. → Utilization of temperature distribution in exergy calculations. → Evaluation of eight energetic and exergetic parameters for the system.

  13. Irradiated fuel performance evaluation technology development

    International Nuclear Information System (INIS)

    Koo, Yang Hyun; Bang, J. G.; Kim, D. H.

    2012-01-01

    Alpha version performance code for dual-cooled annular fuel under steady state operation, so called 'DUOS', has been developed applying performance models and proposed methodology. Furthermore, nonlinear finite element module which could be integrated into transient/accident fuel performance code was also developed and evaluated using commercial FE code. The first/second irradiation and PIE test of annular pellet for dual-cooled annular fuel in the world have been completed. In-pile irradiation test DB of annular pellet up to burnup of 10,000 MWd/MTU through the 1st test was established and cracking behavior of annular pellet and swelling rate at low temperature were studied. To do irradiation test of dual-cooled annular fuel under PWR's simulating steady-state conditions, irradiation test rig/rod design/manufacture of mock-up/performance test have been completed through international collaboration program with Halden reactor project. The irradiation test of large grain pellets has been continued from 2002 to 2011 and completed successfully. Burnup of 70,000 MWd/MTU which is the highest burnup among irradiation test pellets in domestic was achieved

  14. A theoretical and experimental investigation of propeller performance methodologies

    Science.gov (United States)

    Korkan, K. D.; Gregorek, G. M.; Mikkelson, D. C.

    1980-01-01

    This paper briefly covers aspects related to propeller performance by means of a review of propeller methodologies; presentation of wind tunnel propeller performance data taken in the NASA Lewis Research Center 10 x 10 wind tunnel; discussion of the predominent limitations of existing propeller performance methodologies; and a brief review of airfoil developments appropriate for propeller applications.

  15. Performance measurement, expectancy and agency theory: An experimental study

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2008-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. This model implies that, for a given compensation scheme, the agent’s optimal effort is unrelated to the amount of noise in the performance measure. In contrast, expectancy

  16. Performance measurement, expectancy and agency theory: An experimental study

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2005-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. An important implication of this model is that, for a given compensation scheme, the agent's optimal effort choice is unrelated to the amount of noise in the performance

  17. Experimental Physical Sciences Vistas Performance through Science Winter 2017

    Energy Technology Data Exchange (ETDEWEB)

    Kippen, Karen Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cruz, James Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hockaday, Mary Yvonne P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lacerda, Alex Hugo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilburn, Wesley Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Batha, Steven H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bronkhorst, Curt Allan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Eric [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carnes, Jay Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Del Mauro, Diana [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeYoung, Anemarie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Freibert, Franz Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fronzak, Hannah Kristina [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gray, III, George Thompson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hooks, Daniel Edwin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martineau, Rick Lorne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martz, Joseph Christopher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Migliori, Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Poling, Charles C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Prestridge, Katherine Philomena [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schraad, Mark William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stevens, Michael Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); White, Morgan Curtis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-23

    This issue of Experimental Physical Sciences Vistas focuses on the integrated science that plays a critical role in Los Alamos National Laboratory’s support of the nation’s nuclear deterrent. I hope you will enjoy reading about these accomplishments, opportunities, and challenges.

  18. Experimental study of hole cleaning performance in underbalanced

    African Journals Online (AJOL)

    ADEBOYE

    EXPERIMENTAL SET UP. The flow loop (Figure 1) ... In mud tank, the entire body is covered with heating element ... established using 1.0Hp and 1.5Hp centrifugal pumps respectively and ... The mud was properly mixed until homogeneous ...

  19. Evaluating performance-based test and specifications for sulfate resistance in concrete

    Science.gov (United States)

    2000-12-01

    This research project involved an experimental evaluation of the sulfate resistance of various concretes and mortars for the purpose of establishing performance-based specifications for the durability of concrete against sulfate attack. The research ...

  20. Experimental Evaluation of Actinide Transport in a Fractured Granodiorite

    Energy Technology Data Exchange (ETDEWEB)

    Dittrich, Timothy M. [Los Alamos National Laboratory; Reimus, Paul W. [Los Alamos National Laboratory

    2015-03-16

    The objective of this study was to demonstrate and evaluate new experimental methods for quantifying the potential for actinide transport in deep fractured crystalline rock formations. We selected a fractured granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model system because field experiments have already been conducted with uranium and additional field experiments using other actinides are planned at the site. Thus, working on this system provides a unique opportunity to compare lab experiment results with fieldscale observations. Rock cores drilled from the GTS were shipped to Los Alamos National Laboratory, characterized by x-ray diffraction and microscopy, and used in batch sorption and column breakthrough experiments. Solutions with pH 6.8 and 8.8 were tested. Solutions were switched to radionuclide-free synthetic Grimsel groundwater after near-steady actinide/colloid breakthrough occurred in column experiments. We are currently evaluating actinide adsorption/desorption rates as a function of water chemistry (initial focus on pH), with future testing planned to evaluate the influence of carbonate concentrations, flow rates, and mineralogy in solutions and suspensions with bentonite colloids. (auth)

  1. The role of a blue ocean strategy on performance evaluation

    Directory of Open Access Journals (Sweden)

    Mojtaba Tabari

    2014-08-01

    Full Text Available This paper develops a balanced scorecard (BSC in order to prepare a comprehensive tool for performance evaluation. In this way, an experimental test is conducted in the Resorts of Ramsar Green City located in the north of Iran, in which the factors of a blue ocean strategy influence on the dimensions of the BSC. The sample number of this study consists of 90 managers and experts of the employees who work for Resorts of Ramsar Green City. The acquired data are analyzed with using the t-test. The obtained results show that the blue ocean strategy changes in the objects and the scales of the BSC.

  2. Autoradiographic thyroid evaluation in short-term experimental diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Nascimento-Saba C.C.A.

    1998-01-01

    Full Text Available Previous studies have shown that in vitro thyroid peroxidase (TPO iodide oxidation activity is decreased and thyroid T4-5'-deiodinase activity is increased 15 days after induction of experimental diabetes mellitus (DM. In the present study we used thyroid histoautoradiography, an indirect assay of in vivo TPO activity, to determine the possible parallelism between the in vitro and in vivo changes induced by experimental DM. DM was induced in male Wistar rats (about 250 g body weight by a single ip streptozotocin injection (45 mg/kg, while control (C animals received a single injection of the vehicle. Seven and 30 days after diabetes induction, each diabetic and control animal was given ip a tracer dose of 125I (2 µCi, 2.5 h before thyroid excision. The glands were counted, weighed, fixed in Bouin's solution, embedded in paraffin and cut. The sections were stained with HE and exposed to NTB-2 emulsion (Kodak. The autohistograms were developed and the quantitative distribution of silver grains was evaluated with a computerized image analyzer system. Thyroid radioiodine uptake was significantly decreased only after 30 days of DM (C: 0.38 ± 0.05 vs DM: 0.20 ± 0.04%/mg thyroid, P<0.05 while in vivo TPO activity was significantly decreased 7 and 30 days after DM induction (C: 5.3 and 4.5 grains/100 µm2 vs DM: 2.9 and 1.6 grains/100 µm2, respectively, P<0.05 . These data suggest that insulin deficiency first reduces in vivo TPO activity during short-term experimental diabetes mellitus

  3. Experimental validation of the buildings energy performance (PEC assessment methods with reference to occupied spaces heating

    Directory of Open Access Journals (Sweden)

    Cristian PETCU

    2010-01-01

    Full Text Available This paper is part of the series of pre-standardization research aimed to analyze the existing methods of calculating the Buildings Energy Performance (PEC in view of their correction of completing. The entire research activity aims to experimentally validate the PEC Calculation Algorithm as well as the comparative application, on the support of several case studies focused on representative buildings of the stock of buildings in Romania, of the PEC calculation methodology for buildings equipped with occupied spaces heating systems. The targets of the report are the experimental testing of the calculation models so far known (NP 048-2000, Mc 001-2006, SR EN 13790:2009, on the support provided by the CE INCERC Bucharest experimental building, together with the complex calculation algorithms specific to the dynamic modeling, for the evaluation of the occupied spaces heat demand in the cold season, specific to the traditional buildings and to modern buildings equipped with solar radiation passive systems, of the ventilated solar space type. The schedule of the measurements performed in the 2008-2009 cold season is presented as well as the primary processing of the measured data and the experimental validation of the heat demand monthly calculation methods, on the support of CE INCERC Bucharest. The calculation error per heating season (153 days of measurements between the measured heat demand and the calculated one was of 0.61%, an exceptional value confirming the phenomenological nature of the INCERC method, NP 048-2006. The mathematical model specific to the hourly thermal balance is recurrent – decisional with alternating paces. The experimental validation of the theoretical model is based on the measurements performed on the CE INCERC Bucharest building, within a time lag of 57 days (06.01-04.03.2009. The measurements performed on the CE INCERC Bucharest building confirm the accuracy of the hourly calculation model by comparison to the values

  4. Evaluation of Performance Indexes of Emergency Department

    Directory of Open Access Journals (Sweden)

    Alireza Baratloo

    2015-02-01

    Full Text Available Introduction: The importance of evaluating performance indicators in the emergency department, as one of the most important departments of hospital, is obvious to everyone. Therefore, in this study we aimed to appraise the five performance indicators, approved by the ministry of health, in Shohadaye Tajrish hospital, Tehran, Iran. Methods: In a descriptive cross-sectional study based on the profiles of all the patients admitted to the emergency department, performance indicators in the emergency department were evaluated. The study was divided into 2 parts about the establishment of emergency medicine system and training the medical staff: the first 6 months of 1392 and the second. Then these 2 periods were compared using Mann-Whitney U test while P< 0.05 was considered as the level of significance. Results: Of the studied indicators, mean triage time was 6.04 minutes in the first 6 months which was reduced to 1.5 minutes in the second 6 months (p=0.016. In addition, the percentage of patients who moved out of the department in 12 hours was lowered from 97.3% in the first period to 90.4% in the second (p=0.004. While, the percentage of patients who were decided upon in 6 hours (p=0.2, unsuccessful CPR percentage (p=0.34 and patients discharged against medical advice (p=0.42 showed no significant difference. Conclusion: The results of this study showed that the establishment of the emergency medicine system in the emergency department could lead to more efficient triage. Due to the differences made after their establishment including: different pattern of the patients admitted, increased stay of the patients in the department due to their need for prolonged intensive care, a raise in patient referral to the hospital by pre-hospital services and a higher percentage of occupied hospital beds, other indicators have not shown a significant improvement.

  5. Experimentation and evaluation of advanced integrated system concepts

    Science.gov (United States)

    Ross, M.; Garrigus, K.; Gottschalck, J.; Rinearson, L.; Longee, E.

    1980-09-01

    This final report examines the implementation of a time-phased test bed for experimentation and evaluation of advanced system concepts relative to the future Defense Switched Network (DSN). After identifying issues pertinent to the DSN, a set of experiments which address these issues are developed. Experiments are ordered based on their immediacy and relative importance to DSN development. The set of experiments thus defined allows requirements for a time phased implementation of a test bed to be identified, and several generic test bed architectures which meet these requirements are examined. Specific architecture implementations are costed and cost/schedule profiles are generated as a function of experimental capability. The final recommended system consists of two separate test beds: a circuit switch test bed, configured around an off-the-shelf commercial switch, and directed toward the examination of nearer term and transitional issues raised by the evolving DSN; and a packet/hybrid test bed, featuring a discrete buildup of new hardware and software modules, and directed toward examination of the more advanced integrated voice and data telecommunications issues and concepts.

  6. Experimental evaluation of J in cracked straight and curved pipes under bending

    International Nuclear Information System (INIS)

    Moulin, D.; Touboul, F.; Foucher, N.; Lebey, J.; Acker, D.

    1989-01-01

    An experimental program is being carried out at the CEA Saclay in collaboration with FRAMATOME and IPSN with a view to validate analysis methods applicable for evaluation of leak before break behavior in P.W.R. piping. A large experimental work was already performed in USA, Germany and Japan and cracked pipes made of stainless steel material under bending. The methods of analysis got same validations for straight pipes. However applicability to elbows and comparison with toughness values obtained on small specimens like CT specimens was not completely dealt with

  7. Performance analysis of small-scale experimental facility of TWDEC

    International Nuclear Information System (INIS)

    Kawana, Ryoh; Ishikawa, Motoo; Takeno, Hiromasa; Yamamoto, Takayoshi; Yasaka, Yasuyoshi

    2008-01-01

    The objective of the present paper is to analyze small-scale experimental facilities of TWDEC (Travelling Wave type Direct Energy Converter) and to propose a modification in regard to a measuring device of the facilities by means of numerical simulation with the axisymmetrical two-dimensional approximation (a PIC method). The numerical simulation has given the following results: (1) tendency of the numerical results agree with the experimental results on the measured deceleration efficiency, (2) the deceleration efficiency measured in the experiment will increase if the radius of Faraday cup installed in the experiment increases and (3) the wave of condensation and rarefaction of measured electric charge density, which is averaged in the r-direction below the radius of Faraday cup, is not formed enough with a small radius of Faraday cup because of the r component of electric field which is induced by the electrode geometry

  8. Performance Measurement, Expectancy and Agency Theory: An Experimental Study

    OpenAIRE

    Randolph Sloof; Mirjam van Praag

    2007-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. An important implication of this model is that, for a given compensation scheme, the agent's optimal effort choice is unrelated to the amount of noise in the performance measure. In contrast, expectancy theory as developed by psychologists predicts that effort levels are increasing in the signal-to-noise ratio. We conduct a real effort laboratory experiment to assess the...

  9. Thyroidal radio autographic evaluation in experimental diabetes mellitus

    International Nuclear Information System (INIS)

    Nascimento-Saba, C.C.A.; Brito, A.C.; Pereira, M.J.S.; Carvalho, J.J.; Roshental, D.

    1997-01-01

    Full text. There is a well known correlation between diabetes mellitus (DM) and thyroid diseases. Previous studies have shown that the thyroid peroxidase (TPO) 'in vitro' iodide-oxidation activity is decreased and the thyroid T 4-dasanide is increased 15 days after induction of experimental DM. In the present study we evaluated radioautography, an indirect assay of 'in vivo' T P O activity. D M was induced in male Wistar rats (circa 250 g body weight) by a single i.p. streptozotocin injection (45 mg/kg). One group of D M animals received insulin (2 U/day, N P H), starting 48 h after streptozotocin. 2μ Ci of 125 I were given by i.p. injection, 2.5 h before thyroid excision, after 7 or 30 days of diabetes. The glands were counted, weighed, fixed in Bouin's solution, embedded in paraffin, cut and HE-stained. The sections were covered with NTB-2 emulsion (Kodak), incubated at 4 deg C for 7 days, before revelation. Quantitative distribution of silver grains was evaluated using the Image Pro-Plus program. The thyroidal 125 I uptake is significantly decreased in diabetic animals after 30 days. The 'in vative P O activity is significantly decreased 7 and 30 days D M induction. This decrease was also present in the insulin-treated animals and the exogenous insulin administration was unable to revert changes induced by experimental D M, at least in the dosage/periodicity used. It seems that the activity of basal membrane is affected after 30 days of D M, however the T P O activity is already affected after 7 days of DM

  10. Performance Demonstration Program Plan for the WIPP Experimental-Waste Characterization Program

    International Nuclear Information System (INIS)

    1991-02-01

    The Performance Demonstration Program is designed to ensure that compliance with the Quality Assurance Objective, identified in the Quality Assurance Program Plan for the WIPP Experimental-Waste Characterization Program (QAPP), is achieved. This Program Plan is intended for use by the WPO to assess the laboratory support provided for the characterization of WIPP TRU waste by the storage/generator sites. Phase 0 of the Performance Demonstration Program encompasses the analysis of headspace gas samples for inorganic and organic components. The WPO will ensure the implementation of this plan by designating an independent organization to coordinate and provide technical oversight for the program (Program Coordinator). Initial program support, regarding the technical oversight and coordination functions, shall be provided by the USEPA-ORP. This plan identifies the criteria that will be used for the evaluation of laboratory performance, the responsibilities of the Program Coordinator, and the responsibilities of the participating laboratories. 5 tabs

  11. Experimental evaluation of tool run-out in micro milling

    Science.gov (United States)

    Attanasio, Aldo; Ceretti, Elisabetta

    2018-05-01

    This paper deals with micro milling cutting process focusing the attention on tool run-out measurement. In fact, among the effects of the scale reduction from macro to micro (i.e., size effects) tool run-out plays an important role. This research is aimed at developing an easy and reliable method to measure tool run-out in micro milling based on experimental tests and an analytical model. From an Industry 4.0 perspective this measuring strategy can be integrated into an adaptive system for controlling cutting forces, with the objective of improving the production quality, the process stability, reducing at the same time the tool wear and the machining costs. The proposed procedure estimates the tool run-out parameters from the tool diameter, the channel width, and the phase angle between the cutting edges. The cutting edge phase measurement is based on the force signal analysis. The developed procedure has been tested on data coming from micro milling experimental tests performed on a Ti6Al4V sample. The results showed that the developed procedure can be successfully used for tool run-out estimation.

  12. 48 CFR 1252.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Performance evaluation....216-72 Performance evaluation plan. As prescribed in (TAR) 48 CFR 1216.406(b), insert the following clause: Performance Evaluation Plan (OCT 1994) (a) A Performance Evaluation Plan shall be unilaterally...

  13. Experimental Evaluation of the Hydrodynamic Response of Crew Boat Hulls

    DEFF Research Database (Denmark)

    Pecher, Arthur; Kofoed, Jens Peter

    This report presents the results of an experimental study on 3 different hulls of crew boats intended for service to offshore wind turbines. Their hydrodynamic behaviour has been tested in various sea states representing general wave conditions that could be expected at offshore wind farms. Two...... main setups were used during the tests, corresponding to the hulls being connected to an offshore windmill and being free floating. The following aspects were the main subjects of investigation: • The Response Amplitude Operators of the hulls in two different configurations and with waves coming from 3...... different directions. • The connection forces between the hulls and the wind turbine pile. • The natural frequency of oscillation. For the study, realistic scale models of the hulls of the crew boats were supplied by the client, Hauschildt Marine. The laboratory tests were performed by Arthur Pecher under...

  14. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... of supply and extract air terminals and different winter and summer boundary conditions. Vertical air temperature, operative temperature and air velocity profiles were measured in different positions in the room, and equivalent temperatures were derived, in order to characterize thermal comfort. Contaminant...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  15. Experimental fracture healing: evaluation using radionuclide bone imaging: concise communication

    International Nuclear Information System (INIS)

    Gumerman, L.W.; Fogel, S.R.; Goodman, M.A.; Hanley, E.N. Jr.; Kappakas, G.S.; Rutkowski, R.; Levine, G.

    1978-01-01

    Radionuclide bone imaging was performed in a rabbit model to observe the course of fracture healing and to establish criteria for distinguishing nonunion and delayed healing from normal healing. Sequential gamma-camera images (with pinhole collimator) were collected and subjected to computer analysis. Five groups were established: (a) control--immobilization; (b) control--immobilization plus periosteal stripping; (c) simple fracture--osteotomy; (d) delayed union--osteotomy plus periosteal stripping; and (e) nonunion--osteotomy, periosteal stripping and polymethyl methacrylate interposed between fracture fragments. Histographic representation of absolute count rates along rabbit tibias followed a predictable pattern in the simple-fracture and delayed-union groups. They differed only in the time of appearance of phases. The non-union group demonstrated no recognizable sequential pattern. In this experimental model, serial bone scanning the quantitative data analysis has shown potential for indicating the course of healing in fractures and for serving as a guide to treatment

  16. NASA Numerical and Experimental Evaluation of UTRC Low Emissions Injector

    Science.gov (United States)

    Hicks, Yolanda R.; Tedder, Sarah A.; Anderson, Robert C.; Iannetti, Anthony C.; Smith, Lance L.; Dai, Zhongtao

    2014-01-01

    Computational and experimental analyses of a PICS-Pilot-In-Can-Swirler technology injector, developed by United Technologies Research Center (UTRC) are presented. NASA has defined technology targets for near term (called "N+1", circa 2015), midterm ("N+2", circa 2020) and far term ("N+3", circa 2030) that specify realistic emissions and fuel efficiency goals for commercial aircraft. This injector has potential for application in an engine to meet the Pratt & Whitney N+3 supersonic cycle goals, or the subsonic N+2 engine cycle goals. Experimental methods were employed to investigate supersonic cruise points as well as select points of the subsonic cycle engine; cruise, approach, and idle with a slightly elevated inlet pressure. Experiments at NASA employed gas analysis and a suite of laser-based measurement techniques to characterize the combustor flow downstream from the PICS dump plane. Optical diagnostics employed for this work included Planar Laser-Induced Fluorescence of fuel for injector spray pattern and Spontaneous Raman Spectroscopy for relative species concentration of fuel and CO2. The work reported here used unheated (liquid) Jet-A fuel for all fuel circuits and cycle conditions. The initial tests performed by UTRC used vaporized Jet-A to simulate the expected supersonic cruise condition, which anticipated using fuel as a heat sink. Using the National Combustion Code a PICS-based combustor was modeled with liquid fuel at the supersonic cruise condition. All CFD models used a cubic non-linear k-epsilon turbulence wall functions model, and a semi-detailed Jet-A kinetic mechanism based on a surrogate fuel mixture. Two initial spray droplet size distribution and spray cone conditions were used: (1) an initial condition (Lefebvre) with an assumed Rosin-Rammler distribution, and 7 degree Solid Spray Cone; and (2) the Boundary Layer Stripping (BLS) primary atomization model giving the spray size distribution and directional properties. Contour and line plots

  17. Barrier performance researches for the safety evaluation

    International Nuclear Information System (INIS)

    Niibori, Yuichi

    2004-01-01

    So far, many researches were conducted to propose a scientific evidence (a safety case) for the realization of geological disposal in Japan. In order to regulate the geological disposal system of radioactive wastes, on the other hand, we need also a holistic approach to integrate various data related for the performance evaluations of the engineered barrier system and the natural barrier system. However, the scientific bases are not sufficient to establish the safety regulation for such a natural system. For example, we often apply the specific probability density function (PDF) to the uncertainty of barrier system due to the essential heterogeneity. However, the applicability is not clear in the regulation point of view. A viewpoint to understand such an applicability of PDFs has been presented. (author)

  18. Performance Evaluation of the SPT-140

    Science.gov (United States)

    Manzella, David; Sarmiento, Charles; Sankovic, John; Haag, Tom

    1997-01-01

    As part of an on-going cooperative program with industry, an engineering model SPT-140 Hall thruster, which may be suitable for orbit insertion and station-keeping of geosynchronous communication satellites, was evaluated with respect to thrust and radiated electromagnetic interference at the NASA Lewis Research Center. Performance measurements were made using a laboratory model propellant feed system and commercial power supplies. The engine was operated in a space simulation chamber capable of providing background pressures of 4 x 10(exp -6) Torr or less during thruster operation. Thrust was measured at input powers ranging from 1.5 to 5 kilowatts with two different output filter configurations. The broadband electromagnetic emission spectra generated by the engine was also measured for a range of frequencies from 0.01 to 18,000 Mhz. These results are compared to the noise threshold of the measurement system and MIL-STD-461C where appropriate.

  19. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  20. Experimental evaluation of a MOSFET dosimeter for proton dose measurements

    International Nuclear Information System (INIS)

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-01-01

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations

  1. Experimental analysis on the performance of lithium based batteries for road full electric and hybrid vehicles

    International Nuclear Information System (INIS)

    Capasso, Clemente; Veneri, Ottorino

    2014-01-01

    Highlights: • Performance analysis for lithium storage technologies, such as Li[NiCoMn]O 2 and LiFePO 4 batteries. • Actual capacity of lithium technologies analyzed almost close to their nominal capacity also for high discharging current. • The charging efficiency for Li[NiCoMn]O 2 positively affects the regenerative breaking and fast recharging operations. • The analyzed battery packs follow dynamic power requirements on performed road driving cycles. • Experimental results demonstrate driving range is much higher when battery packs are based on lithium technology. - Abstract: This paper deals with an experimental evaluation regarding the real performance of lithium based energy storage systems for automotive applications. In particular real working operations of different lithium based storage system technologies, such as Li[NiCoMn]O 2 and LiFePO 4 batteries, are compared in this work from the point of view of their application in supplying full electric and hybrid vehicles, taking as a reference the well-known behavior of lead acid batteries. For this purpose, the experimental tests carried out in laboratory are firstly performed on single storage modules in stationary conditions. In this case the related results are obtained by means of a bidirectional cycle tester based on the IGBT technology, and consent to evaluate, compare and contrast charge/discharge characteristics and efficiency at constant values of current/voltage/power for each storage technology analyzed. Then, lithium battery packs are tested in supplying a 1.8 kW electric power train using a laboratory test bench, based on a 48 V DC bus and specifically configured to simulate working operations of electric vehicles on the road. For this other experimentation the test bench is equipped with an electric brake and acquisition/control system, able to represent in laboratory the real vehicle conditions and road characteristics on predefined driving cycles at different slopes. The obtained

  2. ASR performance analysis of an experimental call routing system

    CSIR Research Space (South Africa)

    Modipa, T

    2009-11-01

    Full Text Available Call routing is an important application of Automatic Speech Recognition (ASR) technology. In this paper the authors discuss the main issues affecting the performance of a call routing system and describe the ASR component of the "Auto...

  3. NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric

    Science.gov (United States)

    Companies | Energy Systems Integration Facility | NREL NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric Companies NREL Evaluates Advanced Solar Inverter Performance for Hawaiian performance and impacts of today's advanced solar inverters, as well as proprietary feedback to the inverter

  4. Performance Evaluation of the United Nations Environment ...

    Science.gov (United States)

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations where more sophisticated monitoring instrumentation was not available. The US EPA has conducted numerous evaluations of other similar sensor pods at its Research Triangle Park, NC research campus and has trained staff as well as established research designs for such efforts. Under the terms of the MCRADA, the US EPA would operate the pod using UNEP provided operating procedures in a manner consistent with its planned intent of deployment. The US EPA would collect air quality monitoring data from the pod involving select environmental measures over a period of approximately one month. Reference monitoring data collected from collocated federal regulatory monitors would be used to establish a comparison between the two systems and thus establishment of performance characteristics. In addition, the US EPA would provide feedback information to the UNEP as to observed ease of use features of the pod that would be beneficial in its future evolution and deployment. The UNEP recently developed a multipollutant sensor pod called the UNEP Air Quality Monitoring Unit, herein simply defined as the UNEP pod (http://aqicn.org/faq/2015-10-28/unep-air-quality-monitoring-station/). First introduced in 20

  5. Air curtain incinerator equipment performance evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    About 50 tonnes of oil-contaminated debris and related wood products were successfully incinerated in a 10-h performance evaluation of a mobile air curtain incinerator. The test was conducted to evaluate the incinerator's ability to combust oil-contaminated trash and debris obtained from oil spill sites. The operating principle of the apparatus involves a diesel engine driving an air blower to deliver ca 20,000 scfm of air into a 5-m long manifold angled at a 30{degree} slope into an incineration tank. A bottomhole aerator is lowered to the bottom of the tank and compressed air is injected into the aerator to control burn efficiency. The blower is engaged once the debris in the tank is burning sufficiently after starting a fire in the debris. The air curtain effect created by the air deflecting off the opposite wall from the blower manifold and bouncing off the bottom and up the side of the incineration tank results in repeated combustion of the gases, thereby significantly reducing the degree of visible smoke emission. The unit is capable of incinerating ca 5 tonnes/h and of generating ca 16 m{sup 3}/h of hot water which can be used for flushing spill sites and cleaning shorelines. 12 figs.

  6. Experimental evaluation of toxicity of selected mixtures used in metallurgy

    Energy Technology Data Exchange (ETDEWEB)

    Drozdz, M; Stawiarska, B; Kucharz, E; Glowacki, A; Janecki, M; Grucka-Mamczar, E; Olczyk, K; Piwowarczyk, B

    1982-01-01

    The investigation is aimed at evaluation of the effects of copper-coating and bonderizing solutions and oil--emulsion used in technological processes in the metallurgic industry upon hematological and biochemical changes in rats' peripheral blood. The studies were performed on male Wistar rats. The solutions were carried onto hairy and depilated skin. Acute toxicity was evaluated in two-weeks' experiment and chronic toxicity in three--months' experiment. The copper-coating solution was found to be most hazardous, whereas the oil emulsion-the least hazardous. The copper-coating and bonderizing solutions, when chronically applied, result in anaemia and changes in the percentage picture of leucocytes, and also increased blood concentration of uric acid, creatinine and hydroxyproline. No significant changes in concentrations of the remaining biochemical indices were found. The results point to synergistic effects of oil-emulsion and copper-coating solution.

  7. [Experimental evaluation of the spraying disinfection efficiency on dental models].

    Science.gov (United States)

    Zhang, Yi; Fu, Yuan-fei; Xu, Kan

    2013-08-01

    To evaluate the disinfect effect after spraying a new kind of disinfectant on the dental plaster models. The germ-free plaster samples, which were smeared with bacteria compound including Staphylococcus aureus, Escherichia coli, Saccharomyces albicans, Streptococcus mutans and Actinomyces viscosus were sprayed with disinfectants (CaviCide) and glutaraldehyde individually. In one group(5 minutes later) and another group(15 minutes later), the colonies were counted for statistical analysis after sampling, inoculating, and culturing which were used for evaluation of disinfecting efficiency. ANOVA was performed using SPSS12.0 software package. All sample bacteria were eradicated after spraying disinfectants(CaviCide) within 5 minutes and effective bacteria control was retained after 15 minutes. There was significant difference between the disinfecting efficiency of CaviCide and glutaraldehyde. The effect of disinfection with spraying disinfectants (CaviCide) on dental models is quick and effective.

  8. Performance Evaluation of Frequent Subgraph Discovery Techniques

    Directory of Open Access Journals (Sweden)

    Saif Ur Rehman

    2014-01-01

    Full Text Available Due to rapid development of the Internet technology and new scientific advances, the number of applications that model the data as graphs increases, because graphs have highly expressive power to model a complicated structure. Graph mining is a well-explored area of research which is gaining popularity in the data mining community. A graph is a general model to represent data and has been used in many domains such as cheminformatics, web information management system, computer network, and bioinformatics, to name a few. In graph mining the frequent subgraph discovery is a challenging task. Frequent subgraph mining is concerned with discovery of those subgraphs from graph dataset which have frequent or multiple instances within the given graph dataset. In the literature a large number of frequent subgraph mining algorithms have been proposed; these included FSG, AGM, gSpan, CloseGraph, SPIN, Gaston, and Mofa. The objective of this research work is to perform quantitative comparison of the above listed techniques. The performances of these techniques have been evaluated through a number of experiments based on three different state-of-the-art graph datasets. This novel work will provide base for anyone who is working to design a new frequent subgraph discovery technique.

  9. Performance evaluations of the ATST secondary mirror

    Science.gov (United States)

    Cho, Myung K.; DeVries, Joseph; Hansen, Eric

    2007-09-01

    The Advanced Technology Solar Telescope (ATST) has a 4.24m off-axis primary mirror designed to deliver diffraction-limited images of the sun. Its baseline secondary mirror (M2) design uses a 0.65m diameter Silicon Carbide mirror mounted kinematically by a bi-pod flexure mechanism at three equally spaced locations. Unlike other common telescopes, the ATST M2 is to be exposed to a significant solar heat loading. A thermal management system will be developed to accommodate the solar loading and minimize "mirror seeing effect" by controlling the temperature difference between the M2 optical surface and the ambient air at the site. Thermo-elastic analyses for steady state thermal behaviors of the ATST secondary mirror was performed using finite element analysis by I-DEAS TM and PCFRINGE TM for the optical analysis. We examined extensive heat transfer simulation cases and their results are discussed. The goal of this study is to evaluate the optical performances of M2 using thermal models and mechanical models. Thermal responses from the models enable us to manipulate time dependent thermal loadings to synthesize the operational environment for the design and development of TMS.

  10. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Directory of Open Access Journals (Sweden)

    Snegirjovs A.

    2016-12-01

    Full Text Available Information on the electrical-driven solar air conditioning (SAC is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW. In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  11. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Science.gov (United States)

    Snegirjovs, A.; Shipkovs, P.; Lebedeva, K.; Kashkarova, G.; Migla, L.; Gantenbein, P.; Omlin, L.

    2016-12-01

    Information on the electrical-driven solar air conditioning (SAC) is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC) systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average) systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW). In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  12. Growth performance of broilers in experimental Reovirus infections

    Directory of Open Access Journals (Sweden)

    Sudhakar P. Awandkar

    Full Text Available Background: The avian reoviruses have emerged to induce various manifestations in chickens. They are associated with disease conditions including malabsorption syndrome, tenosynovitis etc. Reoviruses are an important cause of suboptimum performance in broilers, resulting in poor growth performance. Poultry industry in India is facing a catastrophe due to such infections which go unnoticed in field due to masking of the symptoms by secondary infections and commonly observed nutritional disorders. Aim: To investigate the effect of reovirus infection on overall performance of broiler birds. Material and Methods: The broiler birds were challenged with homologous strains of malabsorption syndrome and tenosynovitis syndrome of reovirus. The growth performance was recorded. Results and conclusion: The growth performance and immune response to NDV did not differ in the birds challenged with tenosynovitis syndrome strain of reo virus as compared to un challenged birds. However, poor live body weight, feed intake, FCR, PE and BPEI and better serum NDV titres were found in chicks challenged with malabsorption syndrome strain of reovirus as compared to the chicks from control group. [Vet World 2012; 5(11.000: 685-689

  13. Experimental evaluation of the concept of supevisory manipulation

    Science.gov (United States)

    Brooks, T. L.; Sheridan, T. B.

    1982-01-01

    A computer-controlled teleoperator system which is based on task-referenced sensor-aided control has been developed to study supervisory manipulation. This system, called SUPERMAN, is capable of performing complicated tasks in real-time by utilizing the operator for high-level functions related to the unpredictable portions of a task, while the subordinate machine performs the more well-defined subtasks under human supervison. To determine whether supervisory control schemes such as these offer any advantage over manual control under real-time conditions, a number of experiments involving both simple and complicated tasks were performed. Six representative tasks were chosen for the study: (1) obtaining a tool from a rack, (2) returning the tool to the rack, (3) removing a nut, (4) placing samples in a storage bin, (5) opening and closing a valve, and (6) digging with a shovel. The experiments were performed under simulated conditions using four forms of manual control (i.e., switch rate, joystick rate, master-slave position control, and master-slave with force feedback), as well as supervisory control. Through these experiments the effectiveness and quality of control were evaluated on the basis of the time required to complete each portion of the task and the type and number of errors which occurred.

  14. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    Science.gov (United States)

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  15. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    International Nuclear Information System (INIS)

    Pereira, L M C

    2017-01-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials. (topical review)

  16. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    Science.gov (United States)

    Pereira, L. M. C.

    2017-10-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials.

  17. Guidance for Evaluating the Safety of Experimental Releases of Mosquitoes, Emphasizing Mark-Release-Recapture Techniques.

    Science.gov (United States)

    Benedict, Mark Q; Charlwood, J Derek; Harrington, Laura C; Lounibos, L Philip; Reisen, William K; Tabachnick, Walter J

    2018-01-01

    Experimental releases of mosquitoes are performed to understand characteristics of populations related to the biology, ability to transmit pathogens, and ultimately their control. In this article, we discuss considerations related to the safety of experimental releases of living mosquitoes, applying principles of good practice in vector biology that protect human health and comfort. We describe specific factors of experimental releases of mosquitoes that we believe are critical to inform institutional biosafety committees and similar review boards to which proposals to conduct mosquito release experiments have been submitted. In this study, "experimental releases" means those that do not significantly increase vector capacity or nuisance biting relative to the unperturbed natural baseline. This document specifically does not address releases of mosquitoes for ongoing control programs or trials of new control methods for which broader assessments of risk are required. It also does not address releases of transgenic or exotic (non-native) mosquito species, both of which require particular regulatory approval. Experimental releases may include females and males and evaluation must consider their effects based on the number released, their genotype and phenotype, the environment into which they are released, and postrelease collection activities. We consider whether increases of disease transmission and nuisance biting might result from proposed experimental releases against the backdrop of natural population size variation. We recommend that experimental releases be conducted in a manner that can be reasonably argued to have insignificant negative effects. Reviewers of proposals for experimental releases should expect applicants to provide such an argument based on evidence from similar studies and their planned activities. This document provides guidance for creating and evaluating such proposals.

  18. ACCOUNTING FOR USERS' INFLATED ASSESSMENTS OF ONLINE CATALOG SEARCH PERFORMANCE AND USEFULNESS: AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Charles R. Hildreth

    2001-01-01

    Full Text Available User-oriented approaches to information retrieval (IR system performance evaluation assign a major role to user satisfaction with search results and overall system performance. Expressed satisfaction with search results is often used as a measure of utility. Many research studies indicate that users of on-line library catalogs (OPACs and other IR systems often express satisfaction with poor search results. This phenomenon of "false positives," inflated assessments of search results and system performance, has not been adequately explained. Non-performance factors such as interface style and ease of use may have an affect on a searcher's satisfaction with search results. The research described in this report investigates this phenomenon. This paper presents the findings of an experimental study which compared users' search performance and assessments of ease of use, system usefulness, and satisfaction with search results after use of a Web OPAC or its conventional counterpart. The primary questions addressed by this research center on the influence of two experimental factors, OPAC search interface style and search task level of difficulty, on the dependent variables: actual search performance, perceptions of ease of use and system usefulness, and assessments of satisfaction with search results. The study also investigated associations between perceived ease of use, system usefulness, and satisfaction with search results. Lastly, the study looked for associations between the dependent variables and personal characteristics. No association was found between satisfaction with search results and actual search performance. Web OPAC searchers outperformed Text OPAC searchers, but search task level of difficulty is a major determinant of search success. A strong positive correlation was found between perceptions of system ease of use and assessments of search results.

  19. Experimental evaluation of a high performance superconducting torquer

    International Nuclear Information System (INIS)

    Goldie, J.H.; Avakian, K.M.; Downer, J.R.; Gerver, M.; Gondhalekar, V.; Johnson, B.G.

    1991-01-01

    SatCon has completed a two-year program to design and build a prototype demonstration of a torque actuator which employs a superconducting field magnet. The program culminated with the successful demonstration of close loop torque control, following a desired double version torque profile to an accuracy of approximately 1% of the peak torque of the profile. The targeted double version possessed a peak torque which matches the torque capacity of the M4500 CMG (controlled moment gyro), the largest Sperry double gimbal CMG. The research provided strong evidence of the feasibility of a SatCon-developed advanced concept CMG, depicted schematically in this paper, which would employ cryoresistive control coils in conjunction with an electromagnetically suspended rotor and superconducting source coil. The cryoresistive coils interact with the superconducting solenoid to develop the desired torque and, in addition, the required suspension forces

  20. INTEGRATED WATER TREATMENT SYSTEM PERFORMANCE EVALUATION

    International Nuclear Information System (INIS)

    Sexton, R.A.; Meeuwsen, W.E.

    2009-01-01

    This document describes the results of an evaluation of the current Integrated Water Treatment System (IWTS) operation against design performance and a determination of short term and long term actions recommended to sustain IWTS performance. The KW IWTS was designed to treat basin water and maintain basin clarity during fuel retrieval, washing, and packaging activities in the KW Basin. The original design was based on a mission that was limited to handling of KW Basin fuel. The use of the IWTS was extended by the decision to transfer KE fuel to KW to be cleaned and packaged using KW systems. The use was further extended for the packaging of two more Multi-Canister Overpacks (MCOs) containing legacy fuel and scrap. Planning is now in place to clean and package Knock Out Pot (KOP) Material in MCOs using these same systems. Some washing of KOP material in the Primary Cleaning Machine (PCM) is currently being done to remove material that is too small or too large to be included in the KOP Material stream. These plans will require that the IWTS remain operational through a campaign of as many as 30 additional MCOs, and has an estimated completion date in 2012. Recent operation of the IWTS during washing of canisters of KOP Material has been impacted by low pressure readings at the inlet of the P4 Booster Pump. The system provides a low pressure alarm at 10 psig, and low-low pressure interlock at 5 psig. The response to these low readings has been to lower total system flow to between 301 and 315 gpm. In addition, the IWTS operator has been required to operate the system in manual mode and make frequent adjustments to the P4 booster pump speed during PCM washes. The preferred mode of operation is to establish a setpoint of 317 gpm for the P4 pump speed and run IWTS in semi-automatic mode. Based on hydraulic modeling compared to field data presented in this report, the low P4 inlet pressure is attributed to restrictions in the 2-inch KOP inlet hose and in the KOP itself

  1. Experimental and theoretical analysis of cell module output performance for a thermophotovoltaic system

    International Nuclear Information System (INIS)

    Xu, Xiaojie; Ye, Hong; Xu, Yexin; Shen, Mingrong; Zhang, Xiaojing; Wu, Xi

    2014-01-01

    Highlights: • An accurate theoretical model for thermophotovoltaic system is constructed. • Parallel connected module is superior if radiator temperature is uneven. • Series connected module is superior if cell temperature is uneven. • Short circuit current of series module rises when the shunt resistance decreases. • Fill factor is not always accurate to evaluate the module performance. - Abstract: An experimental thermophotovoltaic (TPV) system with a cylindrical-geometry radiator was established to test the output performances of modules under different conditions. The results demonstrate that the output performance of a cell module decreases when the combustion power increases because of the uneven temperature of the radiator or cells. On this basis, a theoretical model for a TPV system was constructed to compare the performance under different conditions of the series-connected (SC) module and the parallel-connected (PC) module, and was verified by the experimental results. The influences of the temperature gradient of the radiator or the cell module, and the series and shunt resistance of the TPV cell on the module performance were analyzed in detail. The results demonstrate that the PC module can effectively reduce the mismatch loss of output power caused by the uneven radiator temperature. The PC module, for instance, has a maximum output power of 2.54 times higher than that of the SC module when the radiator temperature difference is 500 K. However, the output performance of the module connected in series is superior to the PC module while the cell temperature is non-uniform. The output power of the SC module is 9.93% higher than that of the PC module at the cell temperature difference of 125 K. The short circuit current of the SC module is sensitive to the series and shunt resistance if the radiator temperature distribution is non-uniform. As the shunt resistance falls from ∞ to 0.5 Ω, the current varies from 1.757 A to 4.488 A when the

  2. Experimental investigation of the seismic performance of the R/C frames with reinforced masonry infills

    Science.gov (United States)

    Tanjung, Jafril; Maidiawati, Nugroho, Fajar

    2017-10-01

    Intensive studies regarding the investigation of seismic performance of reinforced concrete (R/C) frames which are infilled with brick masonry walls have been carried out by several researchers within the last three-decades. According to authors' field and experimentally experiences conclude that the unreinforced brick masonry infills significantly contributes to increase the seismic performance of the R/C frame structure. Unfortunately, the presence of brick masonry infill walls causes several undesirable effects such as short column, soft-storey, torsion and out of plane collapse. In this study, a strengthening technique for the brick masonry infills were experimentally investigated to improve the seismic performance of the R/C frame structures. For this purpose, four experimental specimens have been prepared, i.e. one of bare R/C frame (BF), one of R/C frame infilled with unreinforced brick-masonry wall (IFUM) and two of R/C frames were infilled with reinforced brick-masonry wall (IFRM-1 and IFRM-2). The bare frame and R/C frame infilled with unreinforced brick-masonry wall represents the typical R/C buildings' construction in Indonesia assuming the brick-masonry wall as the non-structural elements. The brick-masonry wall infills in specimens IFRM-1 and IFRM-2 were strengthened by using embedded ϕ4 plain steel bar on their diagonal and center of brick-masonry wall, respectively. All specimens were laterally pushed-over. The lateral loading and its lateral displacement, failure mechanism and their crack pattern were recorded during experimental works. Comparison of the experimental results of these four specimens conclude that the strengthening of the brick-masonry infills wall gave the significantly increasing of the seismic performance of the R/C frame. The seismic performance was evaluated based on the lateral strength of the R/C specimen. The embedded plain steel bar on brick-masonry also reduces the diagonal crack on the brick-masonry wall. It seems that

  3. The experimental assessment of dynamic tire handling performance

    NARCIS (Netherlands)

    Pauwelussen, J.P.

    1999-01-01

    Testing of steady state tire handling performance is nowadays common practice with slip angle sweeps and breaking being simulated in the laboratory with drum or flat belt, or on the road with a test trailer. In recent years, more emphasis is put on dynamic tire models, motivated by ride comfort

  4. Experimental evaluation of an active solar thermoelectric radiant wall system

    International Nuclear Information System (INIS)

    Liu, ZhongBing; Zhang, Ling; Gong, GuangCai; Han, TianHe

    2015-01-01

    Highlights: • A novel active solar thermoelectric radiant wall are proposed and tested. • The novel wall can control thermal flux of building envelope by using solar energy. • The novel wall can eliminate building envelop thermal loads and provide cooling capacity for space cooling. • Typical application issues including connection strategies, coupling with PV system etc. are discussed. - Abstract: Active solar thermoelectric radiant wall (ASTRW) system is a new solar wall technology which integrates thermoelectric radiant cooling and photovoltaic (PV) technologies. In ASTRW system, a PV system transfers solar energy directly into electrical energy to power thermoelectric cooling modes. Both the thermoelectric cooling modes and PV system are integrated into one enclosure surface as radiant panel for space cooling and heating. Hence, ASTRW system presents fundamental shift from minimizing building envelope energy losses by optimizing the insulation thickness to a new regime where active solar envelop is designed to eliminate thermal loads and increase the building’s solar gains while providing occupant comfort in all seasons. This article presents an experimental study of an ASTRW system with a dimension of 1580 × 810 mm. Experimental results showed that the inner surface temperature of the ASTRW is 3–8 °C lower than the indoor temperature of the test room, which indicated that the ASTRW system has the ability to control thermal flux of building envelope by using solar energy and reduce the air conditioning system requirements. Based on the optimal operating current of TE modules and the analysis based upon PV modeling theories, the number and type of the electrical connections for the TE modules in ASTRW system are discussed in order to get an excellent performance in the operation of the ASTRW system

  5. ERESYE - a expert system for the evaluation of uncertainties related to systematic experimental errors

    International Nuclear Information System (INIS)

    Martinelli, T.; Panini, G.C.; Amoroso, A.

    1989-11-01

    Information about systematic errors are not given In EXFOR, the data base of nuclear experimental measurements: their assessment is committed to the ability of the evaluator. A tool Is needed which performs this task in a fully automatic way or, at least, gives a valuable aid. The expert system ERESYE has been implemented for investigating the feasibility of an automatic evaluation of the systematic errors in the experiments. The features of the project which led to the implementation of the system are presented. (author)

  6. Experimental and economical evaluation of a novel biogas digester

    International Nuclear Information System (INIS)

    Rajendran, Karthik; Aslanzadeh, Solmaz; Johansson, Fredrik; Taherzadeh, Mohammad J.

    2013-01-01

    Highlights: • Textile biogas digester was tested with synthetic nutrients and MSW. • Economical evaluation was made with replacement of LPG and kerosene. • The investment is positive until the price of fuel goes down. • Sensitivity analysis was performed to check the stability of the digester. - Abstract: Many developing countries face an energy demand to satisfy the daily needs of the people. Household biogas digesters are among the interesting solutions to meet the energy demands for cooking and lighting, and at the same time taking care of the kitchen wastes. In this study, a novel textile-based biogas digester was developed. The digester was evaluated for biogas production from a synthetic nutrient and an organic fraction of municipal solid waste (OFMSW) as substrates for more than a year. The obtained biogas productivity in both experiments was 570 L/kgVS/day, which indicates that the digester is as efficient in handling of OFMSW as the synthetic nutrients. Based on the obtained biogas production data, the techno-economic evaluation and sensitivity analysis for the process were performed, replacing LPG and kerosene consumption with biogas in households. A 2-m 3 digester can supply the fuel needed for cooking for a family of 4–6 people. The sum of investment and 15-years operational costs of this digester was 656 USD, which can be compared with 1455 USD for subsidized-LPG and 975 USD for kerosene, respectively. The results from the sensitivity analysis show that it was a positive investment, unless the price of kerosene goes down to less than 0.18 USD/L

  7. FORECASTING OF PERFORMANCE EVALUATION OF NEW VEHICLES

    Directory of Open Access Journals (Sweden)

    O. S. Krasheninin

    2016-12-01

    Full Text Available Purpose. The research work focuses on forecasting of performance evaluation of the tractive and non-tractive vehicles that will satisfy and meet the needs and requirements of the railway industry, which is constantly evolving. Methodology. Analysis of the technical condition of the existing fleet of rolling stock (tractive and non-tractive of Ukrainian Railways shows a substantial reduction that occurs in connection with its moral and physical wear and tear, as well as insufficient and limited purchase of new units of the tractive and non-tractive rolling stock in the desired quantity. In this situation there is a necessity of search of the methods for determination of rolling stock technical characteristics. One of such urgent and effective measures is to conduct forecasting of the defining characteristics of the vehicles based on the processes of their reproduction in conditions of limited resources using a continuous exponential function. The function of the growth rate of the projected figure degree for the vehicle determines the logistic characteristic that with unlimited resources has the form of an exponent, and with low ones – that of a line. Findings. The data obtained according to the proposed method allowed determining the expected (future value, that is the ratio of load to volume of the body for non-tractive rolling stock (gondola cars and weight-to-power for tractive rolling stock, the degree of forecast reliability and the standard forecast error, which show high prediction accuracy for the completed procedure. As a result, this will allow estimating the required characteristics of vehicles in the forecast year with high accuracy. Originality. The concept of forecasting the characteristics of the vehicles for decision-making on the evaluation of their prospects was proposed. Practical value. The forecasting methodology will reliably determine the technical parameters of tractive and non-tractive rolling stock, which will meet

  8. Two analytical models for evaluating performance of Gigabit Ethernet Hosts

    International Nuclear Information System (INIS)

    Salah, K.

    2006-01-01

    Two analytical models are developed to study the impact of interrupt overhead on operating system performance of network hosts when subjected to Gigabit network traffic. Under heavy network traffic, the system performance will be negatively affected due to interrupt overhead caused by incoming traffic. In particular, excessive latency and significant degradation in system throughput can be experienced. Also user application may livelock as the CPU power is mostly consumed by interrupt handling and protocol processing. In this paper we present and compare two analytical models that capture host behavior and evaluate its performance. The first model is based Markov processes and queuing theory, while the second, which is more accurate but more complex is a pure Markov process. For the most part both models give mathematically-equivalent closed-form solutions for a number of important system performance metrics. These metrics include throughput, latency and stability condition, CPU utilization of interrupt handling and protocol processing and CPU availability for user applications. The analysis yields insight into understanding and predicting the impact of system and network choices on the performance of interrupt-driven systems when subjected to light and heavy network loads. More, importantly, our analytical work can also be valuable in improving host performance. The paper gives guidelines and recommendations to address design and implementation issues. Simulation and reported experimental results show that our analytical models are valid and give a good approximation. (author)

  9. Performance evaluation of nursing students following competency-based education.

    Science.gov (United States)

    Fan, Jun-Yu; Wang, Yu Hsin; Chao, Li Fen; Jane, Sui-Whi; Hsu, Li-Ling

    2015-01-01

    Competency-based education is known to improve the match between educational performance and employment opportunities. This study examined the effects of competency-based education on the learning outcomes of undergraduate nursing students. The study used a quasi-experimental design. A convenience sample of 312 second-year undergraduate nursing students from northern and southern Taiwan participated in the study. The experimental group (n=163) received competency-based education and the control group received traditional instruction (n=149) in a medical-surgical nursing course. Outcome measures included students' scores on the Objective Structured Clinical Examination, Self-Evaluated Core Competencies Scale, Metacognitive Inventory for Nursing Students questionnaire, and academic performance. Students who received competency-based education had significantly higher academic performance in the medical-surgical nursing course and practicum than did the control group. Required core competencies and metacognitive abilities improved significantly in the competency-based education group as compared to the control group after adjusting for covariates. Competency-based education is worth implementing and may close the gap between education and the ever-changing work environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A free-jet experimental study on the performance of a cavity-type ramjet

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jianguo; Pan, Yu; Liang, Jianhan; Wang, Zhenguo [National University of Defense Technology, ChangSha (China)

    2011-11-15

    Free jet experiments have been conducted to evaluate the performance of a cavity-type ramjet. To prevent uncertainty of combustion parameters, a method to calculate internal thrust from cold flow parameters is brought forward. According to this analysis method, the internal thrust of the cavity-type ramjet increases linearly with the stoichiometric ratio while the specific impulse decreases squarely. The aero-propulsive balance of a conceptive missile is also examined, focusing on the effect of attack angle. Considering both efficiency and performance, an attack angle of 3{approx}6 degrees is recommended. And the free-jet experimental results show that the cavity-type ramjet can supply sufficient thrust for the missile under cruise conditions.

  11. 48 CFR 3052.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... CONTRACT CLAUSES Text of Provisions and Clauses 3052.216-72 Performance evaluation plan. As prescribed in... Evaluation Plan (DEC 2003) (a) A Performance Evaluation Plan shall be unilaterally established by the...

  12. Experimental Study on Fatigue Performance of Foamed Lightweight Soil

    Science.gov (United States)

    Qiu, Youqiang; Yang, Ping; Li, Yongliang; Zhang, Liujun

    2017-12-01

    In order to study fatigue performance of foamed lightweight soil and forecast its fatigue life in the supporting project, on the base of preliminary tests, beam fatigue tests on foamed lightweight soil is conducted by using UTM-100 test system. Based on Weibull distribution and lognormal distribution, using the mathematical statistics method, fatigue equations of foamed lightweight soil are obtained. At the same time, according to the traffic load on real road surface of the supporting project, fatigue life of formed lightweight soil is analyzed and compared with the cumulative equivalent axle loads during the design period of the pavement. The results show that even the fatigue life of foamed lightweight soil has discrete property, the linear relationship between logarithmic fatigue life and stress ratio still performs well. Especially, the fatigue life of Weibull distribution is more close to that derived from the lognormal distribution, in the instance of 50% guarantee ratio. In addition, the results demonstrated that foamed lightweight soil as subgrade filler has good anti-fatigue performance, which can be further adopted by other projects in the similar research domain.

  13. Experimental and Numerical analysis of Metallic Bellow for Acoustic Performance

    Science.gov (United States)

    Panchwadkar, Amit A.; Awasare, Pradeep J., Dr.; Ingle, Ravidra B., Dr.

    2017-08-01

    Noise will concern about the work environment of industry. Machinery environment has overall noise which interrupts communication between the workers. This problem of miscommunication and health hazard will make sense to go for noise attenuation. Modification in machine setup may affect the performance of it. Instead of that, Helmholtz resonator principle will be a better option for noise reduction along the transmission path. Resonator has design variables which gives resonating frequency will help us to confirm the frequency range. This paper deals with metallic bellow which behaves like inertial mass under incident sound wave. Sound wave energy is affected by hard boundary condition of resonator and bellow. Metallic bellow is used in combination with resonator to find out Transmission loss (TL). Microphone attachment with FFT analyzer will give the frequency range for numerical analysis. Numerical analysis of bellow and resonator is carried out to summarize the acoustic behavior of bellow. Bellow can be numerically analyzed to check noise attenuation for centrifugal blower. An impedance tube measurement technique is performed to validate the numerical results for assembly. Dimensional and shape modification can be done to get the acoustic performance of bellow.

  14. Experimental Study on Shear Performance of Bolt in Roadway Supporting

    Directory of Open Access Journals (Sweden)

    D.J. Li

    2014-09-01

    Full Text Available The corner bolt is proved to be effective in the control of floor deformation of roadway, and the relevant studies on bolting mechanisms are of great significance in improving roadway stability. In this paper, two types of shear tests on six forms of bolts are performed by using self-designed shear test device, the electro-hydraulic servo triaxial testing system. The shear characteristics of different types of bolts are obtained. The results show that different bolt rods or different internal filling conditions result in large differences in shear resistance and different deformation adaptability. We find that the filling materials added can improve the shear performance of bolt significantly, and the bolt with steel not only can improve the strength of bolt body, but also has the bimodal characteristic that makes the bolt have the secondary bearing capacity and withstand larger deformation range during the process of shear, and shows a better support performance. Hoping to provide the experiment basis for support design and field application in the future.

  15. Experimental evaluation of structural integrity of scram release electromagnet

    International Nuclear Information System (INIS)

    Patri, Sudheer; Ruhela, S.P.; Punniyamoorthy, R.; Vijayashree, R.; Chandramouli, S.; Kumar, P. Madan; Rajendraprasad, R.; Rao, P. Vijayamohana; Narmadha, S.; Sreedhar, B.K.; Rajan, K.K.

    2014-01-01

    Highlights: • The structural integrity of scram release electromagnet is evaluated against thermal shocks. • A simple test facility, employed for simulating the thermal shocks in a typical FBR, is presented. • The cold shock experienced by electromagnet during scram is simulated. • The testing qualified electromagnet for 11.6 yr of reactor operation. - Abstract: Prototype fast breeder reactor (PFBR), under construction at Kalpakkam, India, plays an important role in the commercialisation of fast breeder reactors (FBR) in India. It consists of two independent, fast acting and diverse shutdown systems. An electromagnet (EM) immersed in sodium acts as scram release device for the second shutdown system of prototype fast breeder reactor. The inside of EM is sealed from the sodium to achieve the required response time and to prevent the exposure of EM coil to sodium. As the EM response time is an important parameter for reactor safety, the integrity of EM is to be maintained under all anticipated loadings. The EM experiences thermal shocks and thermal stresses during reactor transients such as scram. The dissimilar weld joint present in EM is more susceptible to fatigue failure due to these thermal stresses. Failure of weld joint results in the entry of sodium into the EM, increasing its response time with associated safety implications. In this connection, the structural integrity of EM against thermal shocks was experimentally evaluated in Thermal Shock Test Facility. The EM was subjected to 1000 cycles of thermal shocks, which constitutes 29% of total number of shocks required to qualify the EM for 40 years of reactor operation, thus qualifying it for 11.6 yr of reactor operation. The testing has enhanced the confidence level for safe and reliable operation of EM of DSRDM in PFBR. The testing not only qualified the EM for use in reactor but also provided input for licensing the erection of DSRDM on reactor pile. Moreover, it provided a direction for

  16. Experimental performance of an E×B chopper system

    Directory of Open Access Journals (Sweden)

    C. Wiesner

    2017-02-01

    Full Text Available Beam operation of a novel E×B chopper system has started in the low-energy beam transport (LEBT section of the accelerator-driven neutron source FRANZ. The chopper is designed for low-energy high-perveance beams and high repetition rates, and will finally operate with 120 keV protons. It combines a static magnetic deflection field with a pulsed electric compensation field in a Wien filter-type E×B configuration. The chopper was designed, manufactured and successfully commissioned at the required repetition rate of 257 kHz using a 14 keV helium beam with up to 3.5 mA of beam current. Beam pulses with rise times of (120±10  ns, flat-top lengths of (85±10  ns to (120±10  ns and full width at half maximum (FWHM between (295±10  ns and (370±10  ns were experimentally achieved.

  17. Evaluating performance of high efficiency mist eliminators

    Energy Technology Data Exchange (ETDEWEB)

    Waggoner, Charles A.; Parsons, Michael S.; Giffin, Paxton K. [Mississippi State University, Institute for Clean Energy Technology, 205 Research Blvd, Starkville, MS (United States)

    2013-07-01

    Processing liquid wastes frequently generates off gas streams with high humidity and liquid aerosols. Droplet laden air streams can be produced from tank mixing or sparging and processes such as reforming or evaporative volume reduction. Unfortunately these wet air streams represent a genuine threat to HEPA filters. High efficiency mist eliminators (HEME) are one option for removal of liquid aerosols with high dissolved or suspended solids content. HEMEs have been used extensively in industrial applications, however they have not seen widespread use in the nuclear industry. Filtering efficiency data along with loading curves are not readily available for these units and data that exist are not easily translated to operational parameters in liquid waste treatment plants. A specialized test stand has been developed to evaluate the performance of HEME elements under use conditions of a US DOE facility. HEME elements were tested at three volumetric flow rates using aerosols produced from an iron-rich waste surrogate. The challenge aerosol included submicron particles produced from Laskin nozzles and super micron particles produced from a hollow cone spray nozzle. Test conditions included ambient temperature and relative humidities greater than 95%. Data collected during testing HEME elements from three different manufacturers included volumetric flow rate, differential temperature across the filter housing, downstream relative humidity, and differential pressure (dP) across the filter element. Filter challenge was discontinued at three intermediate dPs and the filter to allow determining filter efficiency using dioctyl phthalate and then with dry surrogate aerosols. Filtering efficiencies of the clean HEME, the clean HEME loaded with water, and the HEME at maximum dP were also collected using the two test aerosols. Results of the testing included differential pressure vs. time loading curves for the nine elements tested along with the mass of moisture and solid

  18. Experimental and Numerical Evaluation of the By-Pass Flow in a Catalytic Plate Reactor for Hydrogen Production

    DEFF Research Database (Denmark)

    Sigurdsson, Haftor Örn; Kær, Søren Knudsen

    2011-01-01

    Numerical and experimental study is performed to evaluate the reactant by-pass flow in a catalytic plate reactor with a coated wire mesh catalyst for steam reforming of methane for hydrogen generation. By-pass of unconverted methane is evaluated under different wire mesh catalyst width to reactor...

  19. Sparsity reconstruction in electrical impedance tomography: An experimental evaluation

    KAUST Repository

    Gehre, Matthias

    2012-02-01

    We investigate the potential of sparsity constraints in the electrical impedance tomography (EIT) inverse problem of inferring the distributed conductivity based on boundary potential measurements. In sparsity reconstruction, inhomogeneities of the conductivity are a priori assumed to be sparse with respect to a certain basis. This prior information is incorporated into a Tikhonov-type functional by including a sparsity-promoting ℓ1-penalty term. The functional is minimized with an iterative soft shrinkage-type algorithm. In this paper, the feasibility of the sparsity reconstruction approach is evaluated by experimental data from water tank measurements. The reconstructions are computed both with sparsity constraints and with a more conventional smoothness regularization approach. The results verify that the adoption of ℓ1-type constraints can enhance the quality of EIT reconstructions: in most of the test cases the reconstructions with sparsity constraints are both qualitatively and quantitatively more feasible than that with the smoothness constraint. © 2011 Elsevier B.V. All rights reserved.

  20. Clinical and electrocardiographic evaluation during experimental toad poisoning in dogs

    Directory of Open Access Journals (Sweden)

    AC Camplesi

    2010-01-01

    Full Text Available Accidents involving toad poisoning are frequent and dogs are the most common victims; they become poisoned by biting or ingesting a toad. When released in the organism, the venom is absorbed by both the oral mucosa and the digestive tract, initiating its toxic action. The aim of this work was to evaluate the clinical and electrocardiographic aspects of dogs subjected to experimental toad poisoning, as well as their response to treatment with propranolol. Twenty dogs were divided into two groups, a control group (n = 5 and a poisoned group (n = 15. After general anesthesia, the control group received a placebo, while the poisoned group received a venom aliquot through an orogastric tube. Results were tested through multivariate analysis (p < 0.05. The animals in the poisoned group had gastrointestinal symptoms including emesis, intense salivation, hyperemic or congested oral mucosa and pasty diarrhea. Non-responsive mydriasis, nystagmus, depression, stupor, tachypnea, opisthotonus and ataxia were also manifested by 100% of the poisoned animals. Affected dogs had an increase in blood pressure, statistically significant throughout study. Five poisoned animals developed ventricular tachycardia and were treated with propranolol (0.5 mg/kg IV. All propranolol-treated animals returned to normal sinus rhythm, which evidences the efficacy of this drug to treat ventricular arrhythmias caused by toad venom.

  1. Experimental evaluation of new chitin-chitosan graft for duraplasty.

    Science.gov (United States)

    Pogorielov, M; Kravtsova, A; Reilly, G C; Deineka, V; Tetteh, G; Kalinkevich, O; Pogorielova, O; Moskalenko, R; Tkach, G

    2017-02-01

    Natural materials such as collagen and alginate have promising applications as dural graft substitutes. These materials are able to restore the dural defect and create optimal conditions for the development of connective tissue at the site of injury. A promising material for biomedical applications is chitosan-a linear polysaccharide obtained by the deacetylation of chitin. It has been found to be nontoxic, biodegradable, biofunctional and biocompatible in addition to having antimicrobial characteristics. In this study we designed new chitin-chitosan substitutes for dura mater closure and evaluated their effectiveness and safety. Chitosan films were produced from 3 % of chitosan (molar mass-200, 500 or 700 kDa, deacetylation rate 80-90%) with addition of 20% of chitin. Antimicrobial effictively and cell viability were analysed for the different molar masses of chitosan. The film containing chitosan of molar mass 200 kDa, had the best antimicrobial and biological activity and was successfully used for experimental duraplasty in an in vivo model. In conclusion the chitin-chitosan membrane designed here met the requirements for a dura matter graft exhibiting the ability to support cell growth, inhibit microbial growth and biodegradade at an appropriate rate. Therefore this is a promising material for clinical duroplasty.

  2. Experimental Evaluation of Internet of Things in the Educational Environment

    Directory of Open Access Journals (Sweden)

    Amr Elsaadany

    2017-09-01

    Full Text Available In the trials of utilization of technology for the society, efforts have shown benefits of the ICT use in facilitating education from different perspectives based on different waves of technological change. The recent development in technologies has also resulted in change of user behavior and usage patterns towards different areas of life, and consequently in the area of education. A new wave of change has started and is expecting to proliferate with stronger connectivity and interoperability of various devices, named as the Internet of Things (IoT. The internet of things is expected to give strong impacts on different areas of life including healthcare, transportation, smart homes, smart campus, and more. Consequently, there are inherent benefits to the education environment that are not yet well established in literature. The paper studies the potential benefit and impact of the IoT evolution concept in both the physical and the virtual learning environment and suggests a paradigm with use case scenarios. The results of an experimental evaluation on the aspects of applying IoT technology in education are presented and discussed in order to verify the set of related hypotheses.

  3. Robot-assisted intracerebral hemorrhage evacuation: an experimental evaluation

    Science.gov (United States)

    Burgner, Jessica; Swaney, Philip J.; Lathrop, Ray A.; Weaver, Kyle D.; Webster, Robert J.

    2013-03-01

    We present a novel robotic approach for the rapid, minimally invasive treatment of Intracerebral Hemorrhage (ICH), in which a hematoma or blood clot arises in the brain parenchyma. We present a custom image-guided robot system that delivers a steerable cannula into the lesion and aspirates it from the inside. The steerable cannula consists of an initial straight tube delivered in a manner similar to image-guided biopsy (and which uses a commercial image guidance system), followed by the sequential deployment of multiple individual precurved elastic tubes. Rather than deploying the tubes simultaneously, as has been done in nearly all prior studies, we deploy the tubes one at a time, using a compilation of their individual workspaces to reach desired points inside the lesion. This represents a new paradigm in active cannula research, defining a novel procedure-planning problem. A design that solves this problem can potentially save many lives by enabling brain decompression both more rapidly and less invasively than is possible through the traditional open surgery approach. Experimental results include a comparison of the simulated and actual workspaces of the prototype robot, and an accuracy evaluation of the system.

  4. Performance evaluation of precast prestressed concrete pavement.

    Science.gov (United States)

    2007-11-01

    This report describes in detail an experimental investigation of an innovative precast prestressed concrete pavement (PPCP) system used to rehabilitate a 1,000 ft. section of interstate highway located on the northbound lanes of I-57 near Charleston,...

  5. Evaluation of Ultrafiltration Performance for Phospholipid Separation

    Science.gov (United States)

    Aryanti, N.; Wardhani, D. H.; Maulana, Z. S.; Roberto, D.

    2017-11-01

    Ultrafiltration membrane for degumming of crude palm oil has been applied as an alternative method since the membrane process required less procedure than the conventional degumming. This research focused on the examination of ultrafiltration performance for phospholipid separation from model crude palm oil degumming. Specifically, profile flux and rejection, as well as blocking mechanism, were investigated. Feed consisting of Refined Crude Palm Oil - Isopropanol - Lecithin mixtures were represented as crude palm oil degumming. Lecithin was denoted a phospholipid component, and the concentrations of lecithin in feed were varied to 0.1%, 0.2%, and 0.3%. The concentration of phospholipid was determined as phosphor content. At the concentration of lecithin in feed representing phospholipid concentration of 8,45 mg/kg, 8,45 mg/kg, 24,87 mg/kg and 57,58 mg/kg, respectively. Flux profiles confirmed that there was a flux decline during filtration. In addition, the lecithin concentrations do not significantly effect on further flux decline. Rejection characteristic and phospholipid concentration in the permeate showed that the phospholipid rejections by ultrafiltration were in the range of 23-79,5% representing permeate’s phospholipid concentration of 1,73 - 44,25 mg/kg. Evaluation of fouling mechanism by Hermia’s blocking model confirmed that the standard blocking is the dominant mechanism in the ultrafiltration of lecithin mixture.

  6. Experimental evaluation of furosemide renography in unobstructed and partially obstructed upper urinary tracts in pigs

    Energy Technology Data Exchange (ETDEWEB)

    Harving, N.; Christiansen, P.; Taagehoj-Jensen, F.; Frokjaer, J.; Djurhuus, J.C.; Mortensen, J. (Institute of Experimental Clinical Research, University of Aarhus (Denmark))

    1991-06-01

    To evaluate the reliability and the constancy of the furosemide renography an experimental evaluation of the test has been performed. A standardized unilateral partial proximal ureteral obstruction was applied to 11 pigs. Preoperatively and again weekly in the three weeks following obstruction a furosemide renogram (FR) was done. The furosemide renography was a very constant parameter in the unobstructed kidney (85%) and in the partly obstructed kidney (85%). A type I FR pattern (O'Reilly classification) was an exact indicator of an unobstructed pelvis. After partial ureteral obstruction, an immediate change in the FR pattern was seen either into type II or type IIIa renography. In this experimental study furosemide renography was found to be a reliable tool in the differentiation between the unobstructed normal renal pelves and the partly obstructed dilated renal pelves.

  7. Experimental study on the performance of pervious concrete

    Science.gov (United States)

    Liu, Haojie; Liu, Rentai; Yang, Honglu; Ma, Chenyang; Zhou, Heng

    2018-02-01

    With the construction of sponge city, the pervious concrete material has been developed rapidly. A high-performance pervious concrete is developed by using cement, silica fume (SF) and superplasticizer (SP). The effects of SF, SP, aggregate size, water-cement ration and aggregate-cement ratio on the permeability coefficient, compressive strength and flexural strength are studied by controlling variables, and exploring the corrosion resistance and abrasion resistance of pervious concrete. The results show that using 0.5% SP, 5% SF and small aggregate can greatly improve the strength. There is an optimum value for water-cement ratio to make the strength and permeability coefficient maximum. Compared to ordinary pervious concrete, the corrosion resistance and abrasion resistance of this pervious concrete are very good.

  8. Design and experimentally measure a high performance metamaterial filter

    Science.gov (United States)

    Xu, Ya-wen; Xu, Jing-cheng

    2018-03-01

    Metamaterial filter is a kind of expecting optoelectronic device. In this paper, a metal/dielectric/metal (M/D/M) structure metamaterial filter is simulated and measured. Simulated results indicate that the perfect impedance matching condition between the metamaterial filter and the free space leads to the transmission band. Measured results show that the proposed metamaterial filter achieves high performance transmission on TM and TE polarization directions. Moreover, the high transmission rate is also can be obtained when the incident angle reaches to 45°. Further measured results show that the transmission band can be expanded through optimizing structural parameters. The central frequency of the transmission band is also can be adjusted through optimizing structural parameters. The physical mechanism behind the central frequency shifted is solved through establishing an equivalent resonant circuit model.

  9. Progress in irradiation performance of experimental uranium - Molybdenum dispersion fuel

    International Nuclear Information System (INIS)

    Hofman, Gerard L.; Meyer, Mitchell K.

    2002-01-01

    High-density dispersion fuel experiment, RERTR-4, was removed from the Advanced Test Reactor (ATR) after reaching a peak U-235 burnup of ∼80% and is presently undergoing postirradiation examination at the ANL alpha-gamma hot cells. This test consists of 32 mini fuel plates of which 27 were fabricated with nominally 6 and 8 g cm -3 atomized and machined uranium alloy powders containing 7 wt% and 10 wt% molybdenum. In addition, two miniplates containing solid U-10 wt% Mo foils and three containing 6 g cm -3 U 3 Si 2 are part of the test. The results of the postirradiation examination and analysis of RERTR-4 in conjunction with data from previous tests performed to lower burnup will be presented. (author)

  10. EXPERIMENTAL INVESTIGATION OF SOLAR POND PERFORMANCE IN KARABUK ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Mehmet ÖZKAYMAK

    2004-01-01

    Full Text Available The solar energy, one of the alternative energy sources, can be economically and cheaply and efficiently collected with solar ponds. In this study, varying concentrations of sodium carbonate dilution in the solar pond in terms of heat storage performance has been examined. Experiment apparatus has been located Zonguldak Karaelmas University Karabük Technical Education Faculty. Five experiments with different density levels have been done and the changes in the temperature and density have been presented graphically within the solar pond. The experiments show that the temperature difference between the bottom and top level of solar pond is max. 21 °C and the highest temperature in lower convective zone (LCZ has been measured as 49 °C.

  11. Context-sensitive service discovery experimental prototype and evaluation

    DEFF Research Database (Denmark)

    Balken, Robin; Haukrogh, Jesper; L. Jensen, Jens

    2007-01-01

    The amount of different networks and services available to users today are increasing. This introduces the need for a way to locate and sort out irrelevant services in the process of discovering available services to a user. This paper describes and evaluates a prototype of an automated discovery...... and selection system, which locates services relevant to a user, based on his/her context and the context of the available services. The prototype includes a multi-level, hierarchical system approach and the introduction of entities called User-nodes, Super-nodes and Root-nodes. These entities separate...... the network in domains that handle the complex distributed service discovery, which is based on dynamically changing context information. In the prototype, a method for performing context-sensitive service discovery has been realised. The service discovery part utilizes UPnP, which has been expanded in order...

  12. Experimental evaluation of the Skylab orbital workshop ventilation system concept

    Science.gov (United States)

    Allums, S. L.; Hastings, L. J.; Ralston, J. T.

    1972-01-01

    Extensive testing was conducted to evaluate the Orbital Workshop ventilation concept. Component tests were utilized to determine the relationship between operating characteristics at 1 and 0.34 atm. System tests were conducted at 1 atm within the Orbital Workshop full-scale mockup to assess delivered volumetric flow rate and compartment air velocities. Component tests with the Anemostat circular diffusers (plenum- and duct-mounted) demonstrated that the diffuser produced essentially equivalent airflow patterns and velocities in 1- and 0.34-atm environments. The tests also showed that the pressure drop across the diffuser could be scaled from 1 to 0.34 atm using the atmosphere pressure ratio. Fan tests indicated that the performance of a multiple, parallel-mounted fan cluster could be predicted by summing the single-fan flow rates at a given delta P.

  13. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  14. Experimental testing of the thermal performance of finned air coolers

    International Nuclear Information System (INIS)

    Imhof, A.; Keller, J.; Koelliker, A.

    1988-05-01

    Finned heat exchangers are often used as regenerators in heat recovery systems or as a heat source for heat pump installations. These exchangers are usually operating as air coolers. Heat is extracted from the air flowing through the heat exchanger. If the fin temperature lies below the dew point at the air inlet, water vapour may be condensed, increasing the thermal performance of the cooler. If the air/water heat exchanger is installed outdoors, the blower is usually mounted directly at the exchaner's case. In general this leads to non-ideal air flow conditions. For the sizing of such components the manufacturers dispose of design rules which are based either on theoretical models or on experiments using a uniform air stream. These rules which are mostly internal codes of the individual companies presumably do not take into account some non-ideal conditions such as an inhomogeneous air flow, a poorly sized blower or an increased pressure drop between the fins due to condensed water vapour. Moreover, these codes are possibly not sophisticated enough to enable a correct sizing of the products for any given condition of operation, especially in heat pumps operating under condensation conditions. Therfore, the Swiss Federal Institute for Reactor Research (EIR) carried out a research program dealing with the thermal performance of commercially available finned air coolers. The results give a strong evidence that the sizing of finned air coolers involving a phase change in one of the heat transfer fluids is not yet a procedure belonging to the common knowledge of most of the manufacturers. Moreover, the correct sizing of the blower is at least as important as the sizing of the finned exchanger itself. However, it is evident that there are companies on the Swiss market which use already reliable design tools. 25 refs., 81 figs., 12 tabs

  15. Experimental and Analytical Evaluation of a Composite Honeycomb Deployable Energy Absorber

    Science.gov (United States)

    Jackson, Karen E.; Kellas, Sotiris; Horta, Lucas G.; Annett, Martin S.; Polanco, Michael A.; Littell, Justin D.; Fasanella, Edwin L.

    2011-01-01

    In 2006, the NASA Subsonic Rotary Wing Aeronautics Program sponsored the experimental and analytical evaluation of an externally deployable composite honeycomb structure that is designed to attenuate impact energy during helicopter crashes. The concept, which is designated the Deployable Energy Absorber (DEA), utilizes an expandable Kevlar honeycomb structure to dissipate kinetic energy through crushing. The DEA incorporates a unique flexible hinge design that allows the honeycomb to be packaged and stowed flat until needed for deployment. A variety of deployment options such as linear, radial, and/or hybrid methods can be used. Experimental evaluation of the DEA utilized a building block approach that included material characterization testing of its constituent, Kevlar -129 fabric/epoxy, and flexural testing of single hexagonal cells. In addition, the energy attenuation capabilities of the DEA were demonstrated through multi-cell component dynamic crush tests, and vertical drop tests of a composite fuselage section, retrofitted with DEA blocks, onto concrete, water, and soft soil. During each stage of the DEA evaluation process, finite element models of the test articles were developed and simulations were performed using the explicit, nonlinear transient dynamic finite element code, LS-DYNA. This report documents the results of the experimental evaluation that was conducted to assess the energy absorption capabilities of the DEA.

  16. The establishment of bilateral external iliac artery stenosis model in experimental canines and its angiographic evaluation

    International Nuclear Information System (INIS)

    Xia Yonghui; Li Weixiao; Bi Yonghua; Xu Ke

    2011-01-01

    Objective: To establish an experimental canine model of bilateral external iliac artery stenosis by surgical method with absorbable suture. Methods: Under general anesthesia bilateral external iliac arteries were partly obstructed (about 50%) with absorbable suture in ten dogs. Three months later angiography was performed to evaluate the arterial stricture degree. Results: Bilateral external iliac artery stenosis model was successfully established in eight dogs and the other two dogs died within two weeks after the procedure. Angiography performed three months after the procedure showed that the stricture degree of arterial lumen was (60.6±12.5)%. Conclusion: Satisfactory experimental canine model of bilateral external iliac artery stenosis can be established by surgical method with absorbable suture. This method can be used for reference when peripheral artery stenosis model is to be prepared in larger animals. (authors)

  17. Experimental performance study of a proposed desiccant based air conditioning system.

    Science.gov (United States)

    Bassuoni, M M

    2014-01-01

    An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used as the working desiccant material. HDBAC system is used to serve low sensible heat factor applications. The effect of different parameters such as, process air flow rate, desiccant solution flow rate, evaporator box and condenser box solution temperatures, strong solution concentration and regeneration temperature on the performance of the system is studied. The performance of the system is evaluated using some parameters such as: the coefficient of performance (COPa), specific moisture removal and energy saving percentage. A remarkable increase of about 54% in the coefficient of performance of the proposed system over VCS with reheat is achieved. A maximum overall energy saving of about 46% is observed which emphasizes the use of the proposed system as an energy efficient air conditioning system.

  18. Novel experimental methodology for the characterization of thermodynamic performance of advanced working pairs for adsorptive heat transformers

    International Nuclear Information System (INIS)

    Frazzica, Andrea; Sapienza, Alessio; Freni, Angelo

    2014-01-01

    This paper presents a novel experimental protocol for the evaluation of the thermodynamic performance of working pairs for application in adsorption heat pumps and chillers. The proposed approach is based on the experimental measurements of the main thermo-physical parameters of adsorbent pairs, by means of a DSC/TG apparatus modified to work under saturated vapour conditions, able to measure the ads-/desorption isobars and heat flux as well as the adsorbent specific heat under real boundary conditions. Such kind of activity allows to characterize the thermodynamic performance of an adsorbent pair allowing the estimation of the thermal Coefficient Of Performance (COP) both for heating and cooling applications, only relying on experimental values. The experimental uncertainty of the method has been estimated to be around 2%, for the COP evaluation. In order to validate the proposed procedure, a first test campaign has been carried out on the commercial adsorbent material, AQSOA-Z02, produced by MPI (Mitsubishi Plastics Inc.), while water was used as refrigerant. The proposed experimental methodology will be applied on several other adsorbent materials, either already on the market or still under investigation, in order to get an easy and reliable method to compare thermodynamic performance of adsorptive working pairs

  19. Experimental study of heat transfer performance in a flattened AGHP

    International Nuclear Information System (INIS)

    Tao Hanzhong; Zhang Hong; Zhuang Jun; Jerry Bowman, W.

    2008-01-01

    Round mini-axial grooved heat pipes (AGHP) with a diameter of 6 mm and a length of 210 mm were pressed into flattened heat pipes with a thickness of 3.5 mm, 3 mm, 2.5 mm and 2 mm, respectively. The article measured the heat transfer limit, thermal resistance and evaporation heat transfer coefficient of the said AGHPs and analyzed and studied the result. The result indicates: the heat transfer limit decreased with the increase of flattening degree. The heat transfer limit of the 2 mm thick flattened AGHP was only 1/4 of that of the φ 6 mm round AGHP. The thermal resistance of the 3.5-2.5 mm thick AGHPs basically maintained stable at around 0.08 deg. C/W, while the thermal resistance of the 2 mm thick flattened AGHP increased obviously. The variation of the heat transfer coefficient in evaporator section with the change of flattening degree follows a similar rule to the variation of thermal resistance. This article serves as a reference to understanding the heat transfer performance of mini AGHP and to electronic cooling design of AGHP

  20. Experimental study on the performance of a liquid cooling garment with the application of MEPCMS

    International Nuclear Information System (INIS)

    Wang, Tao; Wang, Liang; Bai, Lizhan; Lin, Guiping; Bu, Xueqin; Liu, Xiangyang; Xie, Guanghui

    2015-01-01

    Highlights: • MEPCMS was applied in a liquid cooling garment for space applications. • Extensive experimental study on the performance of the LCG was conducted. • LCG was assessed by heat dissipation, temperature control and thermal comfort. • Proper match of relevant parameters was crucial in enhancing LCG performance. • 26% enhancement in heat dissipation was achieved by MEPCMS compared to water. - Abstract: As a novel working fluid, microencapsulated phase change material suspension (MEPCMS) exhibits obvious superiority in both heat transfer and temperature control compared with traditional ones. In this paper, extensive experimental study on the performance of a liquid cooling garment (LCG) with the application of this novel working fluid was conducted for future space applications. The main task for a LCG is to efficiently collect, transport and dissipate the metabolic heat produced from the human body. In the experiment, a thermal manikin was employed to simulate the human body, and the performance of the LCG with MEPCMS as the working fluid was evaluated by a variety of aspects such as heat dissipation, temperature control, pump power consumption and thermal comfort under both steady state and transient conditions. Experimental results show that the inlet temperature, mass flowrate and volume concentration of the MEPCMS are three key parameters affecting the performance of the LCG, which can be enhanced significantly by a proper combination of these parameters. Otherwise, the performance of the LCG will deteriorate or even be worse than that using water as the working fluid. When the inlet temperature, mass flowrate and volume concentration of the MEPCMS were selected as 11 °C, 200 g/min and 20% respectively, the heat dissipation of the LCG was enhanced by up to 26% with no obvious increase of the pump power compared with that using water as the working fluid, the temperature distribution in the human body became more uniform, and the capability

  1. Aeroelastic performance evaluation of a flexure box morphing airfoil concept

    Science.gov (United States)

    Pankonien, Alexander M.; Inman, Daniel J.

    2014-04-01

    The flexure-box morphing aileron concept utilizes Macro-Fiber Composites (MFCs) and a compliant box to create a conformal morphing aileron. This work evaluates the impact of the number of MFCs on the performance, power and mass of the aileron by experimentally investigating two different actuator configurations: unimorph and bimorph. Implemented in a NACA 0012 airfoil with 304.8 mm chord, the unimorph and bimorph configurations are experimentally tested over a range of flow speeds from 5 to 20 m/s and angles of attack from -20 to 20 degrees under aerodynamic loads in a wind tunnel. An embedded flexible sensor is installed in the aileron to evaluate the effect of aerodynamic loading on tip position. For both design choices, the effect of actuation on lift, drag and pitching moment coefficients are measured. Finally, the impact on aileron mass and average power consumption due to the added MFCs is considered. The results showed the unimorph exhibiting superior ability to influence flow up to 15 m/s, with equivalent power consumption and lower overall mass. At 20 m/s, the bimorph exhibited superior control over aerodynamic forces and the unimorph experienced significant deformation due to aerodynamic loading.

  2. Experimental Evaluation of MHD Generators Operating at High Hall Coefficients

    International Nuclear Information System (INIS)

    Barthelemy, R.R.; Stephan, B.G.; Cooper, R.F.

    1966-01-01

    The experimental evaluation of such open-cycle MHD generator operation, particularly at large values of the Hall parameter and Mach number, is scarce. A flexible combustion-driven MHD generator test facility is being constructed to investigate various generator-operating parameters, generator configurations and designs, and component materials. The plasma source is a combustion chamber in which toluene, or another suitable fuel, is burned with gaseous oxygen diluted with nitrogen. Potassium hydroxide seed is injected with the fuel to produce the necessary plasma conductivity. The gas stream is accelerated in a supersonic nozzle and then flows through the channel. The Hall channel is constructed of water-cooled Inconel rings suitably grooved for the zirconia electrode material. The rings are insulated from each other with Teflon spacers which are shielded from the high temperature gas by a layer of alumina refractory. The channel consists of 54 water-cooled rings assembled in three independent sections. Provisions for instrumentation consist of 15 points for static pressure measurement along the nozzle, channel and diffuser; 20 thermocouple measurements; 3 split rings for transverse current measurements; a voltmeter panel for all 54 electrodes; and all necessary fluid and electrical monitoring instruments. The channel is followed by a diffuser in which some of the dynamic pressure of the gas stream is recovered. The magnet is an iron core design with coils wound of hollow conductor to permit of water-cooling for high power operation. The magnet can operate at field strengths of up to 23 kG. Details of the test programme planned for the generator (commissioning at the end of 1966) are given. (author)

  3. An Experimental Investigation of Leak Rate Performance of a Subscale Candidate Elastomer Docking Space Seal

    Science.gov (United States)

    Garafolo, Nicholas G.; Daniels, Christopher C.

    2011-01-01

    A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.

  4. comparative performance evaluation of an existing and modified

    African Journals Online (AJOL)

    PROF. BARTH EKWEME

    and fan speeds of 2800 rpm as against the existing cylinder and fan speeds of 934 rpm. The performance evaluation for ... KEYWORDS: Acha, fonio, dehuller, performance evaluation, ... centrifugal force as a result of the rotation of the cylinder.

  5. Patterned Armor Performance Evaluation for Multiple Impacts

    National Research Council Canada - National Science Library

    De

    2003-01-01

    .... Performance characteristics of an ideal patterned armor with respect to multiple hits are discussed, and the types of single-shot ballistic data needed to quantify that performance are presented...

  6. Evaluating Library Staff: A Performance Appraisal System.

    Science.gov (United States)

    Belcastro, Patricia

    This manual provides librarians and library managers with a performance appraisal system that measures staff fairly and objectively and links performance to the goals of the library. The following topics are addressed: (1) identifying expectations for quality service or standards of performance; (2) the importance of a library's code of service,…

  7. Experimental study on control performance of tuned liquid column dampers considering different excitation directions

    Science.gov (United States)

    Altunişik, Ahmet Can; Yetişken, Ali; Kahya, Volkan

    2018-03-01

    This paper gives experimental tests' results for the control performance of Tuned Liquid Column Dampers (TLCDs) installed on a prototype structure exposed to ground motions with different directions. The prototype structure designed in the laboratory consists of top and bottom plates with four columns. Finite element analyses and ambient vibration tests are first performed to extract the natural frequencies and mode shapes of the structure. Then, the damping ratio of the structure as well as the resonant frequency, head-loss coefficient, damping ratio, and water height-frequency diagram of the designed TLCD are obtained experimentally by the shaking table tests. To investigate the effect of TLCDs on the structural response, the prototype structure-TLCD coupled system is considered later, and its natural frequencies and related mode shapes are obtained numerically. The acceleration and displacement time-histories are obtained by the shaking table tests to evaluate its damping ratio. To consider different excitation directions, the measurements are repeated for the directions between 0° and 90° with 15° increment. It can be concluded from the study that TLCD causes to decrease the resonant frequency of the structure with increasing of the total mass. Damping ratio considerably increases with installing TLCD on the structure. This is more pronounced for the angles of 0°, 15°, 30° and 45°.

  8. Combined theoretical and experimental analysis of processes determining cathode performance in solid oxide fuel cells.

    Science.gov (United States)

    Kuklja, M M; Kotomin, E A; Merkle, R; Mastrikov, Yu A; Maier, J

    2013-04-21

    Solid oxide fuel cells (SOFC) are under intensive investigation since the 1980's as these devices open the way for ecologically clean direct conversion of the chemical energy into electricity, avoiding the efficiency limitation by Carnot's cycle for thermochemical conversion. However, the practical development of SOFC faces a number of unresolved fundamental problems, in particular concerning the kinetics of the electrode reactions, especially oxygen reduction reaction. We review recent experimental and theoretical achievements in the current understanding of the cathode performance by exploring and comparing mostly three materials: (La,Sr)MnO3 (LSM), (La,Sr)(Co,Fe)O3 (LSCF) and (Ba,Sr)(Co,Fe)O3 (BSCF). Special attention is paid to a critical evaluation of advantages and disadvantages of BSCF, which shows the best cathode kinetics known so far for oxides. We demonstrate that it is the combined experimental and theoretical analysis of all major elementary steps of the oxygen reduction reaction which allows us to predict the rate determining steps for a given material under specific operational conditions and thus control and improve SOFC performance.

  9. Experimental evaluation of ballistic hazards in imaging diagnostic center

    International Nuclear Information System (INIS)

    Karpowicz, Jolanta; Gryz, Krzysztof

    2013-01-01

    Serious hazards for human health and life and devices in close proximity to the magnetic resonance scanners (MRI scanners) include the effects of being hit by ferromagnetic objects attracted by static magnetic field (SMF) produced by scanner magnet – the so-called ballistic hazards classified among indirect electromagnetic hazards. International safety guidelines and technical literature specify different SMF threshold values regarding ballistic hazards – e.g. 3 mT (directive 2004/40/EC, EN 60601-2-33), and 30 mT (BMAS 2009, directive proposal 2011). Investigations presented in this article were performed in order to experimentally verify SMF threshold for ballistic hazards near MRI scanners used in Poland. Investigations were performed with the use of a laboratory source of SMF (0–30 mT) and MRI scanners of various types. The levels of SMF in which metal objects of various shapes and 0.4–500 g mass are moved by the field influence were investigated. The distance from the MRI scanners (0.2–3T) where hazards may occur were also investigated. Objects investigated under laboratory conditions were moved by SMF of 2.2–15 mT magnetic flux density when they were freely suspended, but were moved by the SMF of 5.6–22 mT when they were placed on a smooth surface. Investigated objects were moved in fields of 3.5–40 mT by MRI scanners. Distances from scanner magnet cover, where ballistic hazards might occur are: up to 0.5 m for 0.2–0.3T scanners; up to 1.3 m for 0.5T scanners; up to 2.0 m for 1.5T scanners and up to 2.5 m for 3T scanners (at the front and back of the magnet). It was shown that SMF of 3 mT magnetic flux density should be taken as the threshold for ballistic hazards. Such level is compatible with SMF limit value regarding occupational safety and health-protected areas/zones, where according to the Polish labor law the procedures of work environment inspection and prevention measures regarding indirect electromagnetic hazards should be applied

  10. Experimental evaluation of ballistic hazards in imaging diagnostic center.

    Science.gov (United States)

    Karpowicz, Jolanta; Gryz, Krzysztof

    2013-04-01

    Serious hazards for human health and life and devices in close proximity to the magnetic resonance scanners (MRI scanners) include the effects of being hit by ferromagnetic objects attracted by static magnetic field (SMF) produced by scanner magnet - the so-called ballistic hazards classified among indirect electromagnetic hazards. International safety guidelines and technical literature specify different SMF threshold values regarding ballistic hazards - e.g. 3 mT (directive 2004/40/EC, EN 60601-2-33), and 30 mT (BMAS 2009, directive proposal 2011). Investigations presented in this article were performed in order to experimentally verify SMF threshold for ballistic hazards near MRI scanners used in Poland. Investigations were performed with the use of a laboratory source of SMF (0-30 mT) and MRI scanners of various types. The levels of SMF in which metal objects of various shapes and 0.4-500 g mass are moved by the field influence were investigated. The distance from the MRI scanners (0.2-3T) where hazards may occur were also investigated. Objects investigated under laboratory conditions were moved by SMF of 2.2-15 mT magnetic flux density when they were freely suspended, but were moved by the SMF of 5.6-22 mT when they were placed on a smooth surface. Investigated objects were moved in fields of 3.5-40 mT by MRI scanners. Distances from scanner magnet cover, where ballistic hazards might occur are: up to 0.5 m for 0.2-0.3T scanners; up to 1.3 m for 0.5T scanners; up to 2.0 m for 1.5T scanners and up to 2.5 m for 3T scanners (at the front and back of the magnet). It was shown that SMF of 3 mT magnetic flux density should be taken as the threshold for ballistic hazards. Such level is compatible with SMF limit value regarding occupational safety and health-protected areas/zones, where according to the Polish labor law the procedures of work environment inspection and prevention measures regarding indirect electromagnetic hazards should be applied. Presented results

  11. 10 CFR 1045.9 - RD classification performance evaluation.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false RD classification performance evaluation. 1045.9 Section... classification performance evaluation. (a) Heads of agencies shall ensure that RD management officials and those... RD or FRD documents shall have their personnel performance evaluated with respect to classification...

  12. 48 CFR 2452.216-73 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Performance evaluation plan... 2452.216-73 Performance evaluation plan. As prescribed in 2416.406(e)(3), insert the following clause in all award fee contracts: Performance Evaluation Plan (AUG 1987) (a) The Government shall...

  13. 48 CFR 2936.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Evaluation of contractor... Construction 2936.201 Evaluation of contractor performance. The HCA must establish procedures to evaluate construction contractor performance and prepare performance reports as required by FAR 36.201. ...

  14. Theoretical and experimental evaluation of an indirect-fired GAX cycle cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, V.H.; Vidal, A. [Posgrado en Ingenieria, Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Best, R.; Garcia-Valladares, O. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Velazquez, N. [Instituto de Ingenieria, Universidad Autonoma de Baja California, Calle de la Normal S/N, Insurgentes Este, 21280 Mexicali, BC (Mexico)

    2008-06-15

    A theoretical and experimental evaluation of an indirect-fired GAX-Prototype Cooling System (GAX-PCS), using ammonia-water as the working fluid, is presented. The GAX-PCS was designed for a cooling capacity of 10.6 kW (3 tons). A simulation model was developed, calibrated and validated with experimental values in order to predict the performance of the system outside the design parameters. Experimental results were obtained using thermal oil, at temperatures from 180 to 195 C, as heating source. An internal heat recovery in the system of {proportional_to}55% with respect to the total heat supplied in the generator was obtained. Also the performance of the GAX absorption system, integrated to a micro gas turbine (MGT) as a cogeneration system was simulated. Overall efficiencies for the cogeneration system from 29% to 49% were obtained for cooling loads from 5 kW to 20 kW, respectively. With the theoretical and experimental study of the proposed cycle, it is concluded that the GAX-PCS presents potential to compete technically in the Mexican air conditioning market. (author)

  15. Performance evaluation of local colour invariants

    NARCIS (Netherlands)

    Burghouts, G.J.; Geusebroek, J.M.

    2009-01-01

    In this paper, we compare local colour descriptors to grey-value descriptors. We adopt the evaluation framework of Mikolayzcyk and Schmid. We modify the framework in several ways. We decompose the evaluation framework to the level of local grey-value invariants on which common region descriptors are

  16. Staff Performance Evaluation in Public Organizations

    Directory of Open Access Journals (Sweden)

    Drumea C.

    2014-12-01

    Full Text Available In public Organizations staff performance is difficult to measure in absence of overall quantitative performance indicators. There are also the qualitative indicators that give an overview on staff’s motivation, strive, ability, commitment to values, teamwork. These aspects are even less easy to illustrate, in private and public sectors equally. In both cases, measuring staff performance at work, as well as its input on the global performance of the organization is a difficult task which has in practice different approaches. Subsequently, this paper is discussing the system indicators and performance triggers used in International Organizations UN affiliated, in order to adjust staff classification and benefits to their staff’s performance.

  17. Experimental Effects of Student Evaluations Coupled with Collaborative Consultation on College Professors' Instructional Skills

    NARCIS (Netherlands)

    Knol, M.H.; in 't Veld, R.; Vorst, H.C.M.; van Driel, J.H.; Mellenbergh, G.J.

    2013-01-01

    This experimental study concerned the effects of repeated students’ evaluations of teaching coupled with collaborative consultation on professors’ instructional skills. Twenty-five psychology professors from a Dutch university were randomly assigned to either a control group or an experimental

  18. Subjective Performance Evaluations, Self-esteem, and Ego-threats in Principal-agent Relations

    DEFF Research Database (Denmark)

    Sebald, Alexander Christopher; Walzl, Markus

    find that agents sanction whenever the feedback of principals is below their subjective self-evaluations even if the agents' payoff is independent of the principals' feedback. Based on our experimental analysis we propose a principal-agent model with subjective performance evaluations that accommodates...

  19. Performance evaluation of CFRP-rubber shock absorbers

    Science.gov (United States)

    Lamanna, Giuseppe; Sepe, Raffaele

    2014-05-01

    In the present work a numerical investigation on the energy absorbing capability of dedicated structural components made of a carbon fiber reinforced polymer and an emulsion polymerised styrene butadiene rubber is reported. The shock absorbers are devices designed to absorb large amounts of energy by sacrificing their own structural integrity. Their aim is to cushion the effects of an impact phenomenon with the intent to preserve other structures from global failure or local damaging. Another important role of shock absorbers is reducing the peak of the acceleration showed during an impact phenomenon. This effect is of considerable interest in the case of vehicles to preserve passengers' safety. Static and dynamic numerical results are compared with experimental ones in terms of mean crushing forces, energy and peak crushing. The global performance of the absorbers has been evaluated by referencing to a proposed quality index.

  20. Performance evaluation of CFRP-rubber shock absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Lamanna, Giuseppe, E-mail: giuseppe.lamanna@unina2.it; Sepe, Raffaele, E-mail: giuseppe.lamanna@unina2.it [Department of Industrial and Information Engineering, Second University of Naples, via Roma, 29 - 81031 Aversa (Italy)

    2014-05-15

    In the present work a numerical investigation on the energy absorbing capability of dedicated structural components made of a carbon fiber reinforced polymer and an emulsion polymerised styrene butadiene rubber is reported. The shock absorbers are devices designed to absorb large amounts of energy by sacrificing their own structural integrity. Their aim is to cushion the effects of an impact phenomenon with the intent to preserve other structures from global failure or local damaging. Another important role of shock absorbers is reducing the peak of the acceleration showed during an impact phenomenon. This effect is of considerable interest in the case of vehicles to preserve passengers’ safety. Static and dynamic numerical results are compared with experimental ones in terms of mean crushing forces, energy and peak crushing. The global performance of the absorbers has been evaluated by referencing to a proposed quality index.

  1. Performance evaluation of clay fly ash brick masonry

    Energy Technology Data Exchange (ETDEWEB)

    Kute, S.; Deodhar, S.V. [K.K. Wagh College of Engineering, Panchavati (India). Dept. of Civil Engineering

    2003-07-01

    Despite inexorable trends of automation in manufacturing industry throughout the world, the conventional brick manufacturing practices have remained largely unchanged since the dawn of civilization in India. This has imposed restrictions on quality of bricks in general. The paper highlights the results derived from an extensive experimental work on performance evaluation of brick masonry. Four types of bricks, three values of joint thickness and fineness modulus of sand, and two grades of mortar with four different proportions were used as samples. Fly ash was from Nashik Thermal Power Station in Maharashtra, India. The results show that the brick masonry of 40% fly ash bricks and mortar with 20% fly ash as replacement to cement with 1:4 and 1:6 proportion gives optimum strength and advocates use of fly ash for this combination. 8 tabs.

  2. Evaluating Robot-Operator Job Performance

    National Research Council Canada - National Science Library

    Moses, Franklin L; Brooks, Peter S; Hofmann, M; Johnson, E; Laveson, J; Zaccaro, S

    2007-01-01

    .... Tests that do include performance of the human operator often rely on qualitative observations -- observer judgments and interviews about workload, situation awareness, cognitive issues, and so on...

  3. Preliminary experimental evaluation of a four wheel motors, batteries plus ultracapacitors and series hybrid powertrain

    Energy Technology Data Exchange (ETDEWEB)

    Rambaldi, Lorenzo [Interuniversity Research Center on Sustainable Development, Sapienza University of Rome, Rome (Italy); Bocci, Enrico [Department of Mechanics and Aeronautics, Sapienza University of Rome, Rome (Italy); Orecchini, Fabio [Guglielmo Marconi University, Rome (Italy)

    2011-02-15

    This paper reports the preliminary experimental evaluation of a four wheel motors series hybrid prototype equipped with an internal combustion engine coupled to a generator and an energy recovery system (batteries plus ultracapacitors). The paper analyses global efficiency (energy dissipated to overcome the dissipative forces on energy dissipated in fuel), autonomy in electric configuration, and the efficiency of the regenerative braking system. The tests were carried out in a test cell equipped with a chassis dynamometer. The tests were performed according to the current regulated procedures. A constant speed test was performed in order to evaluate the autonomy of the vehicle in the electric configuration. The results show that the real tank to wheels efficiency is about 30% for HOST as a series hybrid and 79% for HOST as an electric vehicle. (author)

  4. Experimental Evaluation of Simulation Abstractions for Wireless Sensor Network MAC Protocols

    Directory of Open Access Journals (Sweden)

    G. P. Halkes

    2010-01-01

    Full Text Available The evaluation of MAC protocols for Wireless Sensor Networks (WSNs is often performed through simulation. These simulations necessarily abstract away from reality in many ways. However, the impact of these abstractions on the results of the simulations has received only limited attention. Moreover, many studies on the accuracy of simulation have studied either the physical layer and per link effects or routing protocol effects. To the best of our knowledge, no other work has focused on the study of the simulation abstractions with respect to MAC protocol performance. In this paper, we present the results of an experimental study of two often used abstractions in the simulation of WSN MAC protocols. We show that a simple SNR-based reception model can provide quite accurate results for metrics commonly used to evaluate MAC protocols. Furthermore, we provide an analysis of what the main sources of deviation are and thereby how the simulations can be improved to provide even better results.

  5. Performance of the Opalinus Clay under thermal loading: experimental results from Mont Terri rock laboratory (Switzerland)

    Energy Technology Data Exchange (ETDEWEB)

    Gens, A. [Universitat Politència de Catalunya, Barcelona (Spain); Wieczorek, K. [Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) GmbH, Braunschweig (Germany); Gaus, I. [National Cooperative for the Disposal of Radioactive Waste (NAGRA), Wettingen (Switzerland); and others

    2017-04-15

    The paper presents an overview of the behaviour of Opalinus Clay under thermal loading as observed in three in situ heating tests performed in the Mont Terri rock laboratory: HE-B, HE-D and HE-E. The three tests are summarily described; they encompass a broad range of test layouts and experimental conditions. Afterwards, the following topics are examined: determination of thermal conductivity, thermally-induced pore pressure generation and thermally-induced mechanical effects. The mechanisms underlying pore pressure generation and dissipation are discussed in detail and the relationship between rock damage and thermal loading is examined using an additional in situ test: SE-H. The paper concludes with an evaluation of the various thermo-hydro-mechanical (THM) interactions identified in the heating tests. (authors)

  6. Experimental performance of a piston expander in a small- scale organic Rankine cycle

    Science.gov (United States)

    Oudkerk, J. F.; Dickes, R.; Dumont, O.; Lemort, V.

    2015-08-01

    Volumetric expanders are suitable for more and more applications in the field of micro- and small-scale power system as waster heat recovery or solar energy. This paper present an experimental study carried out on a swatch-plate piston expander. The expander was integrated into an ORC test-bench using R245fa. The performances are evaluated in term of isentropic efficiency and filling factor. The maximum efficiency and power reached are respectively 53% and 2 kW. Inside cylinder pressure measurements allow to compute mechanical efficiency and drown P-V diagram. A semi-empirical simulation model is then proposed, calibrated and used to analyse the different sources of losses.

  7. performance evaluation of evolutionary designed conventional AGC ...

    African Journals Online (AJOL)

    In this context, the tuning of a multi-area automatic generation control (AGC) system after deregulation and furthermore, the effect of reheat turbines dynamics in the power system performance, are not yet ... The performances of the tuned two–area AGC system are obtained using appropriate Matlab/Simulink models. Finally ...

  8. Performance Evaluation of Blind Tropospheric Delay correction ...

    African Journals Online (AJOL)

    This report represents an appraisal of the performance of the GPT2w and UNB3M models with accurate International GNSS Service (IGS)- tropospheric estimations for fifteen IGS stations over a period of 1 year on the Africa continent. Both models perform significantly better at low latitudes than higher latitudes. There was ...

  9. Experimental and numerical performance analysis of a converging channel heat exchanger for PV cooling

    International Nuclear Information System (INIS)

    Baloch, Ahmer A.B.; Bahaidarah, Haitham M.S.; Gandhidasan, Palanichamy; Al-Sulaiman, Fahad A.

    2015-01-01

    Highlights: • Effect of varying converging angle on temperature characteristics of PV surface studied. • Optical, CFD, thermal, and electrical models developed for the analysis. • Experimental measurements carried out for two configurations for June and December. • Using this cooling technique, maximum cell temperature reduction was 57.8%. • Maximum percentage improvement in power output was 35.5%. - Abstract: An experimental and numerical investigation of a cooling technique called as converging channel cooling intended to achieve low and uniform temperature on the surface of PV panel is presented in this paper. Experimental evaluation for an uncooled PV system and a converging channel cooled PV system was carried out subjected to the hot climate of Saudi Arabia for the month of June and December. Detailed modeling was performed using numerical analysis to investigate the effect of changing the converging angle on the thermal characteristics of the PV system. Based on the developed model, two degrees angle showed the best performance in terms of temperature distribution and average cell temperature with a standard deviation of 0.91 °C. A comprehensive system model was developed to assess the performance of PV systems numerically by coupling the optical, radiation, thermal, computational fluid dynamics, and electrical model. Thermal measurements for an uncooled PV showed cell temperature as high as 71.2 °C and 48.3 °C for the month of June and December, respectively. By employing converging cooling, cell temperature was reduced significantly to 45.1 °C for June and to 36.4 °C for December. Maximum percentage improvement in power output was 35.5% whereas maximum percentage increase in the conversion efficiency was 36.1% when compared to the performance of an uncooled PV system. For cost feasibility of an uncooled and cooled PV system, levelized cost of energy (LCE) analysis was performed using the annual energy yield simulation for both systems. LCE

  10. Performance evaluation and specification of trackless tack.

    Science.gov (United States)

    2016-09-01

    Several trackless tack products have come to market in Texas; however, there are currently no specifications to : ensure the products have trackless properties and adequate bond strength. The objectives of this project were to : (1) evaluate the trac...

  11. Relative performance of indoor vector control interventions in the Ifakara and the West African experimental huts.

    Science.gov (United States)

    Oumbouke, Welbeck A; Fongnikin, Augustin; Soukou, Koffi B; Moore, Sarah J; N'Guessan, Raphael

    2017-09-19

    West African and Ifakara experimental huts are used to evaluate indoor mosquito control interventions, including spatial repellents and insecticides. The two hut types differ in size and design, so a side-by-side comparison was performed to investigate the performance of indoor interventions in the two hut designs using standard entomological outcomes: relative indoor mosquito density (deterrence), exophily (induced exit), blood-feeding and mortality of mosquitoes. Metofluthrin mosquito coils (0.00625% and 0.0097%) and Olyset® Net vs control nets (untreated, deliberately holed net) were evaluated against pyrethroid-resistant Culex quinquefasciatus in Benin. Four experimental huts were used: two West African hut designs and two Ifakara hut designs. Treatments were rotated among the huts every four nights until each treatment was tested in each hut 52 times. Volunteers rotated between huts nightly. The Ifakara huts caught a median of 37 Culex quinquefasciatus/ night, while the West African huts captured a median of 8/ night (rate ratio 3.37, 95% CI: 2.30-4.94, P  4-fold higher mosquito exit relative to the West African huts (odds ratio 4.18, 95% CI: 3.18-5.51, P < 0.0001), regardless of treatment. While blood-feeding rates were significantly higher in the West African huts, mortality appeared significantly lower for all treatments. The Ifakara hut captured more Cx. quinquefasciatus that could more easily exit into windows and eave traps after failing to blood-feed, compared to the West African hut. The higher mortality rates recorded in the Ifakara huts could be attributable to the greater proportions of Culex mosquitoes exiting and probably dying from starvation, relative to the situation in the West African huts.

  12. Ridge Distance Estimation in Fingerprint Images: Algorithm and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Tian Jie

    2004-01-01

    Full Text Available It is important to estimate the ridge distance accurately, an intrinsic texture property of a fingerprint image. Up to now, only several articles have touched directly upon ridge distance estimation. Little has been published providing detailed evaluation of methods for ridge distance estimation, in particular, the traditional spectral analysis method applied in the frequency field. In this paper, a novel method on nonoverlap blocks, called the statistical method, is presented to estimate the ridge distance. Direct estimation ratio (DER and estimation accuracy (EA are defined and used as parameters along with time consumption (TC to evaluate performance of these two methods for ridge distance estimation. Based on comparison of performances of these two methods, a third hybrid method is developed to combine the merits of both methods. Experimental results indicate that DER is 44.7%, 63.8%, and 80.6%; EA is 84%, 93%, and 91%; and TC is , , and seconds, with the spectral analysis method, statistical method, and hybrid method, respectively.

  13. Evaluating Motoric Performance of 10 - 12 Age Group Football Players

    Directory of Open Access Journals (Sweden)

    Mehmet KUMARTAŞLI

    2014-08-01

    Full Text Available The aim of this study is to evaluate motoric perfromance of 10 - 12 age group football players. Akdeniz University tiny football team joined as experiment group and 80. Yıl Cumhuriyet Grammar School football team joined to the study as control group. An exercise programme with educational game format considering physical capacities and develeopment features was applied to the student as 8 weeks, 3 days a week. Standing long jump, flexibilty, 20 m. speed, handgrip strength, arm pull, vert ical jump, 10x5 shuttle run and leg strength tests were applied to the students. Handled data were compared at SPSS 10 statistic programme by using Independent Sample t Test. Students’ lenght and weight measurements were calculated. As a result of measurem ents, there were not found diffrences between experimental and control group’s standing long jump, flexibilty, 20 m. speed, handgrip strength, a vertical jump, 10x5 shuttle run and leg strength tests (p>0,05; but in arm pull test, statistically difference was found (p<0,01. While evaluating the physical performance in cihldren and adolescents, growth process is had to be considered. The results of football players that exercise regularly from small ages at physical and physiologic measurements have an importance according to their age. Performance observed in children is sudden and temporary. There are a few studies in the literature about negative psycological effects of starting trainings in early ages.

  14. Hospital evacuation; planning, assessment, performance and evaluation

    OpenAIRE

    Nero C Wabo; P Örtenwall; A Khorram-Manesh

    2012-01-01

    Objective: Malfunction in hospitals' complex internal systems, or extern threats, may result in a hospital evacuation. Factors contributing to such evacuation must be identified, analyzed and action plans should be prepared. Our aims in this study were 1) to evaluate the use of risk and vulnerability analysis as a basis for hospital evacuation plan, 2) to identify risks/hazards triggering an evacuation and evaluate the respond needed and 3) to propose a template with main key points for plann...

  15. Creation of reliable relevance judgments in information retrieval systems evaluation experimentation through crowdsourcing: a review.

    Science.gov (United States)

    Samimi, Parnia; Ravana, Sri Devi

    2014-01-01

    Test collection is used to evaluate the information retrieval systems in laboratory-based evaluation experimentation. In a classic setting, generating relevance judgments involves human assessors and is a costly and time consuming task. Researchers and practitioners are still being challenged in performing reliable and low-cost evaluation of retrieval systems. Crowdsourcing as a novel method of data acquisition is broadly used in many research fields. It has been proven that crowdsourcing is an inexpensive and quick solution as well as a reliable alternative for creating relevance judgments. One of the crowdsourcing applications in IR is to judge relevancy of query document pair. In order to have a successful crowdsourcing experiment, the relevance judgment tasks should be designed precisely to emphasize quality control. This paper is intended to explore different factors that have an influence on the accuracy of relevance judgments accomplished by workers and how to intensify the reliability of judgments in crowdsourcing experiment.

  16. Evaluation of photovoltaic installations performances in Sardinia

    International Nuclear Information System (INIS)

    Ghiani, Emilio; Pilo, Fabrizio; Cossu, Silvestro

    2013-01-01

    Highlights: • One year measurement and performance analysis of grid connected PV power plants. • The analysis of the whole energetic PV transformation chain is presented. • Ambient parameters monitored and compared with the ones available in literature. • Monthly variability of the performance ratio and its correlation with temperature. • Range of variation of performance ratio in plants grouped by typology. - Abstract: This paper aims at providing a performance analysis of a grid connected photovoltaic power plant in Sardinia by investigating on the effective performance ratio of PV installations, with a critical analysis of the whole energetic transformation chain, starting from the incident solar energy, to the DC energy output from the modules and AC energy output from the inverter and transformer. The parameters that can influence the energy production are analyzed in order to find out the critical points in the optimization of the PV system design process. One year measurement and performance analysis of two real-life grid connected PV power plants are presented in the paper, providing up-to-date measurement data, useful to compare the effective energy production of PV plants positioned in different areas of the world. Monthly variability of the performance ratio and its correlation with ambient temperature is also discussed in the paper

  17. Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per

    2013-01-01

    equation. This equation involves a discharge coefficient of the window. The value of the discharge coefficient is the major cause of erroneous estimation of airflow rates. This paper focuses on the experimental study of the discharge coefficient (CD) of a centre-pivot roof window. The measurements were...... performed in the energy flex house of the Technological Institute - Denmark. The discharge coefficient is evaluated for both inflows and outflows. It is concluded that the use of single value of CD for different flap opening angles is one of the cause of erroneous estimation. Likewise, the value of CD...

  18. Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing

    International Nuclear Information System (INIS)

    Lee, J. P.; Kim, H. G.; Han, S. C.

    2012-01-01

    In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

  19. Performance evaluation of cogeneration power plants

    International Nuclear Information System (INIS)

    Bacone, M.

    2001-01-01

    The free market has changed the criteria for measuring the cogeneration plant performances. Further at the technical-economic parameters, are considered other connected at the profits of the power plant [it

  20. Scientific Applications Performance Evaluation on Burst Buffer

    KAUST Repository

    Markomanolis, George S.; Hadri, Bilel; Khurram, Rooh Ul Amin; Feki, Saber

    2017-01-01

    Parallel I/O is an integral component of modern high performance computing, especially in storing and processing very large datasets, such as the case of seismic imaging, CFD, combustion and weather modeling. The storage hierarchy includes nowadays

  1. Experimental evaluation of the power balance model of speed skating.

    Science.gov (United States)

    de Koning, Jos J; Foster, Carl; Lampen, Joanne; Hettinga, Floor; Bobbert, Maarten F

    2005-01-01

    Prediction of speed skating performance with a power balance model requires assumptions about the kinetics of energy production, skating efficiency, and skating technique. The purpose of this study was to evaluate these parameters during competitive imitations for the purpose of improving model predictions. Elite speed skaters (n = 8) performed races and submaximal efficiency tests. External power output (P(o)) was calculated from movement analysis and aerodynamic models and ice friction measurements. Aerobic kinetics was calculated from breath-by-breath oxygen uptake (Vo(2)). Aerobic power (P(aer)) was calculated from measured skating efficiency. Anaerobic power (P(an)) kinetics was determined by subtracting P(aer) from P(o). We found gross skating efficiency to be 15.8% (1.8%). In the 1,500-m event, the kinetics of P(an) was characterized by a first-order system as P(an) = 88 + 556e(-0.0494t) (in W, where t is time). The rate constant for the increase in P(aer) was -0.153 s(-1), the time delay was 8.7 s, and the peak P(aer) was 234 W; P(aer) was equal to 234[1 - e(-0.153(t-8.7))] (in W). Skating position changed with preextension knee angle increasing and trunk angle decreasing throughout the event. We concluded the pattern of P(aer) to be quite similar to that reported during other competitive imitations, with the exception that the increase in P(aer) was more rapid. The pattern of P(an) does not appear to fit an "all-out" pattern, with near zero values during the last portion of the event, as assumed in our previous model (De Koning JJ, de Groot G, and van Ingen Schenau GJ. J Biomech 25: 573-580, 1992). Skating position changed in ways different from those assumed in our previous model. In addition to allowing improved predictions, the results demonstrate the importance of observations in unique subjects to the process of model construction.

  2. Experimental device, corresponding forward model and processing of the experimental data using wavelet analysis for tomographic image reconstruction applied to eddy current nondestructive evaluation

    International Nuclear Information System (INIS)

    Joubert, P.Y.; Madaoui, N.

    1999-01-01

    In the context of eddy current non destructive evaluation using a tomographic image reconstruction process, the success of the reconstruction depends not only on the choice of the forward model and of the inversion algorithms, but also on the ability to extract the pertinent data from the raw signal provided by the sensor. We present in this paper, an experimental device designed for imaging purposes, the corresponding forward model, and a pre-processing of the experimental data using wavelet analysis. These three steps implemented with an inversion algorithm, will allow in the future to perform image reconstruction of 3-D flaws. (authors)

  3. Performance evaluation of a colorimetric hydrazine dosimeter

    Science.gov (United States)

    Brenner, Karen P.; Rose-Pehrsson, Susan L.

    1994-06-01

    A dosimeter for real-time, colorimetric detection of hydrazine in air has been developed. The passive badge consists of a dosimeter card containing a vanillin solution coated on a thin paper substrate. The active patch consists of a thick cellulose substrate coated with a vanillin solution. When placed in a plastic sample holder attached to a personnel pump, up to 5 L/min can be drawn through the active badge substrate. Through a condensation reaction, vanillin reacts with hydrazine to form a colored product that absorbs in the visible region. The hydrazone formed in the reaction is yellow; its intensity is proportional to the dose. When exposed passively to hydrazine, the experimental detection limit is less than 20 ppb-hrs. Extrapolated results indicate a detection limit of less than 5 ppb-hrs for long sampling periods. Actively sampling of hydrazine vapors gives an experimental detection limit of less than 100 ppb-L at a sample rate of 5 L/min. Relative humidity effects on badge response were minor. High humidity enhanced the color development on the vanillin badge; while low humidity had no effect on badge response. Interference testing of the dosimeters revealed a tobacco smoke interference. Preliminary shelf life tests indicated no decrease in sensitivity to hydrazine when stored at room temperature for 6 months.

  4. Numerical and experimental investigation on the performance of safety valves operating with different gases

    International Nuclear Information System (INIS)

    Dossena, V.; Marinoni, F.; Bassi, F.; Franchina, N.; Savini, M.

    2013-01-01

    A detailed analysis of the effect related to the expansion of different gases throughout safety relief valves is carried out both numerically and experimentally. The considered gases are air, argon and ethylene, representative of a wide range of specific heat ratios. A first experimental campaign performed in air and argon on a safety relief valve characterized by connection 1/2″ × 1″ and orifice designation D (diameter 10 mm) according to API 526 showed significant reduction both in disc lift and in exhausted mass flow rate, at the nominal overpressure, when operating with argon. In order to gain a deeper insight into the physics involved and to evaluate the valve behavior with other gases, an extensive numerical testing has been performed by means of an accurate CFD code based on discontinuous Galerkin formulation. Numerical results are at first validated against measurements obtained in air on a 2″ J 3″ safety relief valve proving a remarkable accuracy of the computational method. Then the validated solver is applied on the same computational grid using argon and ethylene as working fluids. The three gases are considered as thermally perfect gases. A critical discussion based on the numerical results allows to clarify the fluid dynamic and physical reasons causing the observed trends both in the opening force and in the discharge coefficient. The main conclusion is that particular care must be taken when a safety valve operates with a fluid characterized by a specific heat ratio greater than the one of the gas used during type testing. -- Highlights: ► Effects of different gases on the discharge capacity and operational characteristics on safety relief valves. ► Influence of different specific heat ratio on safety relief valves discharge coefficient. ► Skilful application of Discontinuous Galerkin CFD solver to safety valves performances prediction

  5. MATLAB platform for Monte Carlo planning and dosimetry experimental evaluation; Plataforma Matlab para planificacion Monte Carlo y evaluacion dosimetrica experimental

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, J. A.; Ureba, A.; Jimenez-Ortega, E.; Pereira-Barbeiro, A. R.; Leal, A.

    2013-07-01

    A new platform for the full Monte Carlo planning and an independent experimental evaluation that it can be integrated into clinical practice. The tool has proved its usefulness and efficiency and now forms part of the flow of work of our research group, the tool used for the generation of results, which are to be suitably revised and are being published. This software is an effort of integration of numerous algorithms of image processing, along with planning optimization algorithms, allowing the process of MCTP planning from a single interface. In addition, becomes a flexible and accurate tool for the evaluation of experimental dosimetric data for the quality control of actual treatments. (Author)

  6. Tribological evaluation for experimental design Al_2O_3 obtained via low pressure injection moulding (LPIM)

    International Nuclear Information System (INIS)

    Dotta, A.L.B.; Costa, C.A.; Farias, M.C.M.; Cunha, M.A da

    2016-01-01

    This work represents the tribological study of Al_2O_3 obtained by LPIM using the experimental design technique to evaluate the interaction of the tribological parameters with the friction and wear. The LPIM process was performed at 90 °C for 24 h. The average friction coefficient for the factorial experimental design varied significantly with the load and the speed when Al_2O_3 was tested with the steel counter body. In general, the wear coefficient was lower for the tribological pair Al_2O_3-steel, in which occurred the formation of an iron oxide tribofilm on the surface. As for the Al_2O_3-Al_2O_3 pair, an intergranular fracture of the surface occurred, in addition to the presence of material adhered on the tracks. (author)

  7. Review of experimental methods for evaluating effective delayed neutron fraction

    Energy Technology Data Exchange (ETDEWEB)

    Yamane, Yoshihiro [Nagoya Univ. (Japan). School of Engineering

    1997-03-01

    The International Effective Delayed Neutron Fraction ({beta}{sub eff}) Benchmark Experiments have been carried out at the Fast Critical Assembly of Japan Atomic Energy Research Institute since 1995. Researchers from six countries, namely France, Italy, Russia, U.S.A., Korea, and Japan, participate in this FCA project. Each team makes use of each experimental method, such as Frequency Method, Rossi-{alpha} Method, Nelson Number Method, Cf Neutron Source Method, and Covariance Method. In this report these experimental methods are reviewed. (author)

  8. Design Methodology and Performance Evaluation of New Generation Sounding Rockets

    Directory of Open Access Journals (Sweden)

    Marco Pallone

    2018-01-01

    Full Text Available Sounding rockets are currently deployed for the purpose of providing experimental data of the upper atmosphere, as well as for microgravity experiments. This work provides a methodology in order to design, model, and evaluate the performance of new sounding rockets. A general configuration composed of a rocket with four canards and four tail wings is sized and optimized, assuming different payload masses and microgravity durations. The aerodynamic forces are modeled with high fidelity using the interpolation of available data. Three different guidance algorithms are used for the trajectory integration: constant attitude, near radial, and sun-pointing. The sun-pointing guidance is used to obtain the best microgravity performance while maintaining a specified attitude with respect to the sun, allowing for experiments which are temperature sensitive. Near radial guidance has instead the main purpose of reaching high altitudes, thus maximizing the microgravity duration. The results prove that the methodology at hand is straightforward to implement and capable of providing satisfactory performance in term of microgravity duration.

  9. Scientific Applications Performance Evaluation on Burst Buffer

    KAUST Repository

    Markomanolis, George S.

    2017-10-19

    Parallel I/O is an integral component of modern high performance computing, especially in storing and processing very large datasets, such as the case of seismic imaging, CFD, combustion and weather modeling. The storage hierarchy includes nowadays additional layers, the latest being the usage of SSD-based storage as a Burst Buffer for I/O acceleration. We present an in-depth analysis on how to use Burst Buffer for specific cases and how the internal MPI I/O aggregators operate according to the options that the user provides during his job submission. We analyze the performance of a range of I/O intensive scientific applications, at various scales on a large installation of Lustre parallel file system compared to an SSD-based Burst Buffer. Our results show a performance improvement over Lustre when using Burst Buffer. Moreover, we show results from a data hierarchy library which indicate that the standard I/O approaches are not enough to get the expected performance from this technology. The performance gain on the total execution time of the studied applications is between 1.16 and 3 times compared to Lustre. One of the test cases achieved an impressive I/O throughput of 900 GB/s on Burst Buffer.

  10. Performance evaluation of matrix gradient coils.

    Science.gov (United States)

    Jia, Feng; Schultz, Gerrit; Testud, Frederik; Welz, Anna Masako; Weber, Hans; Littin, Sebastian; Yu, Huijun; Hennig, Jürgen; Zaitsev, Maxim

    2016-02-01

    In this paper, we present a new performance measure of a matrix coil (also known as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly considering target encoding fields. An optimization problem based on a joint optimization for the non-linear encoding fields is formulated. Based on the derived objective function, a figure of merit of a matrix coil is defined, which is a generalization of a previously known resistive figure of merit for traditional gradient coils. A cylindrical matrix coil design with a high number of elements is used to illustrate the proposed performance measure. The results are analyzed to reveal novel features of matrix coil designs, which allowed us to optimize coil parameters, such as number of coil elements. A comparison to a scaled, existing multi-coil is also provided to demonstrate the use of the proposed performance parameter. The assessment of a matrix gradient coil profits from using a single performance parameter that takes the local encoding performance of the coil into account in relation to the dissipated power.

  11. An Experimental Study on the aerodynamic and aeroacoustic performances of Maple-Seed-Inspired UAV Propellers

    Science.gov (United States)

    Hu, Hui; Ning, Zhe

    2016-11-01

    Due to the auto-rotating trait of maple seeds during falling down process, flow characteristics of rotating maple seeds have been studied by many researchers in recent years. In the present study, an experimental investigation was performed to explore maple-seed-inspired UAV propellers for improved aerodynamic and aeroacoustic performances. Inspired by the auto-rotating trait of maple seeds, the shape of a maple seed is leveraged for the planform design of UAV propellers. The aerodynamic and aeroacoustic performances of the maple-seed-inspired propellers are examined in great details, in comparison with a commercially available UAV propeller purchased on the market (i.e., a baseline propeller). During the experiments, in addition to measuring the aerodynamic forces generated by the maple-seed-inspired propellers and the baseline propeller, a high-resolution Particle Image Velocimetry (PIV) system was used to quantify the unsteady flow structures in the wakes of the propellers. The aeroacoustic characteristics of the propellers are also evaluated by leveraging an anechoic chamber available at the Aerospace Engineering Department of Iowa State University. The research work is supported by National Science Foundation under Award Numbers of OSIE-1064235.

  12. Numerical and Experimental Study on Mixing Performances of Simple and Vortex Micro T-Mixers

    Directory of Open Access Journals (Sweden)

    Mubashshir Ahmad Ansari

    2018-04-01

    Full Text Available Vortex flow increases the interface area of fluid streams by stretching along with providing continuous stirring action to the fluids in micromixers. In this study, experimental and numerical analyses on a design of micromixer that creates vortex flow were carried out, and the mixing performance was compared with a simple micro T-mixer. In the vortex micro T-mixer, the height of the inlet channels is half of the height of the main mixing channel. The inlet channel connects to the main mixing channel (micromixer at the one end at an offset position in a fashion that creates vortex flow. In the simple micro T-mixer, the height of the inlet channels is equal to the height of the channel after connection (main mixing channel. Mixing of fluids and flow field have been analyzed for Reynolds numbers in a range from 1–80. The study has been further extended to planar serpentine microchannels, which were combined with a simple and a vortex T-junction, to evaluate and verify their mixing performances. The mixing performance of the vortex T-mixer is higher than the simple T-mixer and significantly increases with the Reynolds number. The design is promising for efficiently increasing mixing simply at the T-junction and can be applied to all micromixers.

  13. Experimental and Numerical Study on Performance of Ducted Hydrokinetic Turbines with Pre-Swirl Stator Blades.

    Science.gov (United States)

    Gish, Andrew

    2015-11-01

    Ducts (also called shrouds) have been shown to improve performance of hydrokinetic turbines in some situations, bringing the power coefficient (Cp) closer to the Betz limit. Here we investigate optimization of the duct design as well as the addition of stator blades upstream of the turbine rotor to introduce pre-swirl in the flow. A small scale three-bladed turbine was tested in a towing tank. Three cases (bare turbine, with duct, and with duct and stators) were tested over a range of flow speeds. Important parameters include duct cross-sectional shape, blade-duct gap, stator cross-sectional shape, and stator angle. For each test, Cp was evaluated as a function of tip speed ratio (TSR). Experimental results were compared with numerical simulations. Results indicate that ducts and stators can improve performance at slower flow speeds and lower the stall speed compared to a bare turbine, but may degrade performance at higher speeds. Ongoing efforts to optimize duct and stator configurations will be discussed.

  14. Evaluating Performances of Traffic Noise Models | Oyedepo ...

    African Journals Online (AJOL)

    Traffic noise in decibel dB(A) were measured at six locations using 407780A Integrating Sound Level Meter, while spot speed and traffic volume were collected with cine-camera. The predicted sound exposure level (SEL) was evaluated using Burgess, British and FWHA model. The average noise level obtained are 77.64 ...

  15. Evaluation of the diagnostic performance and operational ...

    African Journals Online (AJOL)

    The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Methods: Four rapid ...

  16. Performance Evaluation of Tree Object Matching

    DEFF Research Database (Denmark)

    Somchaipeng, Kerawit; Sporring, Jon; Kreiborg, Sven

    2005-01-01

    Multi-Scale Singularity Trees (MSSTs) represents the deep structure of images in scale-space and provide both the connections between image features at different scales and their strengths. In this report we present and evaluate an algorithm that exploits the MSSTs for image matching. Two versions...

  17. Performance Evaluation of Balanced Pension Plans

    NARCIS (Netherlands)

    L. Andreu (Laura); L.A.P. Swinkels (Laurens)

    2009-01-01

    textabstractThis paper examines the ability of balanced pension plan managers to successfully time the equity and bond market and select the appropriate assets within these markets. In order to evaluate both market timing abilities in these balanced pension plans, we extend the traditional equity

  18. Subjective performance evaluations and employee careers

    DEFF Research Database (Denmark)

    Frederiksen, Anders; Lange, Fabian; Kriechel, Ben

    such data are for evaluating theories in personnel economics and whether findings from such data generalize to the labor force at large. In this paper, we examine personnel data from six large companies and establish how subjective ratings, interpreted as ordinal rankings of employees within narrowly...

  19. Evaluating growth performance of young stands

    Science.gov (United States)

    A. L. Roe; R. E. Benson

    1966-01-01

    A simple procedure for evaluating the diameter growth of young stands in relation to potential growth is described. A comparison technique is developed which contrasts relative diameter of crop trees to the relative diameter growth of the last decade to show the condition and trend of growth in the stand. The method is objective, easy to use, and has several...

  20. The evaluation of myomectomies performed during cesarean ...

    African Journals Online (AJOL)

    Background: We evaluated the data of patients who had applied myomectomy during cesarean section operation in our clinic between April, 2008 and December, 2010. Objective: In this period, 3689 cesarean sections were done in our clinic, we analyzed their data retrospectively and determined 27 myomectomy cases ...

  1. Experimental study on gas-injection enhanced circulation performed with the CIRCE facility

    International Nuclear Information System (INIS)

    Benamati, G.; Foletti, C.; Forgione, N.; Oriolo, F.; Scaddozzo, G.; Tarantino, M.

    2007-01-01

    This paper describes the results of an experimental campaign concerning the possibility of achieving a steady state circulation by gas-injection in a pool containing lead-bismuth eutectic (LBE) as working fluid. The activity was aimed at gaining information about the basic mechanisms of the gas injection enhanced circulation intended as a pumping system for a liquid metal cooled reactor. In particular, the paper is focused on the experimental work performed in the CIRCE large-scale facility, installed at the ENEA Brasimone Centre for studying the fluid-dynamic and operating behaviour of ADS reactor plants cooled by LBE. The gas enhanced circulation tests were carried out for different LBE temperatures (from 200 to 320 deg. C), under isothermal conditions and with a wide range of argon injected flow rates (from 0.5 to 7.0 Nl/s). The gas is injected from the bottom of the riser, by means of an appropriate nozzle, and the liquid metal flow rate is measured by a Venturi-Nozzle flow meter installed in the single phase part of the test section. The obtained results allowed formulating a characteristic curve of the system and evaluating the void fraction distribution along the riser path by means differential pressure measurements, which play an important role to generating the driving force for the circulation

  2. Performance evaluation of 1 kw PEFC

    Energy Technology Data Exchange (ETDEWEB)

    Komaki, Hideaki [Ishikawajima-Harima Heavy Industries Co., Ltd. Tokyo (Japan); Tsuchiyama, Syozo [Shipbuilding Research Association, Minato-ky, Tokyo (Japan)

    1996-12-31

    This report covers part of a joint study on a PEFC propulsion system for surface ships, summarized in a presentation to this Seminar, entitled {open_quote}Study on a PEFC Propulsion System for Surface Ships{close_quotes}, and which envisages application to a 1,500 DWT cargo vessel. The aspect treated here concerns the effects brought on PEFC operating performance by conditions particular to shipboard operation. The performance characteristics were examined through tests performed on a 1 kw stack and on a single cell (Manufactured by Fuji Electric Co., Ltd.). The tests covered the items (1) to (4) cited in the headings of the sections that follow. Specifications of the stack and single cell are as given.

  3. Performance evaluation of PFBR wire type sodium leak detectors

    International Nuclear Information System (INIS)

    Vijayakumar, G.; Rajan, K.K.; Nashine, B.K.; Chandramouli, S.; Madhusoodanan, K.; Kalyanasundaram, P.

    2011-01-01

    Highlights: → Performance evaluation of wire type leak detectors was conducted in LEENA facility by creating sodium leaks. → The lowest leak rate of 214 g/h was detected in 50 min and the highest detection time was 6 h for a leak rate of 222 g/h. → Factors affecting the leak detection time are packing density of thermal insulation, layout of heater, temperature, etc. → Relationship between leak rate and detection time was established and a leak rate of 100 g/h is likely to be detected in 11.1 h. → Contact resistance of leaked sodium increased to 3.5 kilo ohms in 20 h. - Abstract: Wire type leak detectors working on conductivity principle are used for detecting sodium leak in the secondary sodium circuits of fast breeder reactors. It is required to assess the performance of these detectors and confirm that they are meeting the requirements. A test facility by name LEENA was constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam to test the wire type leak detector lay out by simulating different sodium leak rates. This test facility consists of a sodium dump tank, a test vessel, interconnecting pipelines with valves, micro filter and test section with leak simulators. There are three different test sections in the test set up of length 1000 mm each. These test sections simulate piping of Prototype Fast Breeder Reactor (PFBR) secondary circuit and the wire type leak detector layout in full scale. All test sections are provided with leak simulators. A leak simulator consists of a hole of size one mm drilled in the test section and closed with a tapered pin. The tapered pin position in the hole is adjusted by a screw mechanism and there by the annular gap of flow area is varied for getting different leak rates. Various experiments were conducted to evaluate the performance of the leak detectors by creating different sodium leak rates. This paper deals with the details of wire type leak detector layout for the secondary sodium circuit of

  4. Experimental evaluation of optical crosstalk mitigation using phase scrambling

    NARCIS (Netherlands)

    Tangdiongga, E.; Tafur Monroy, I.; Jonker, R.J.W.; Waardt, de H.

    2000-01-01

    We report an experimental study of mitigation of optical homodyne crosstalk by phase scrambling. This is obtained by frequency shifting the signal-crosstalk heating noise power out of the receiver bandwidth. An increased tolerance to crosstalk of 7 and 5 dB is measured in a 2.5-Gb/s link of result

  5. Performance objectives and criteria for plant evaluations

    International Nuclear Information System (INIS)

    1983-04-01

    Maintenance organization and administration should ensure effective implementation and control of maintenance activities. The criteria are: A. The organizational structure is clearly defined. B. Staffing and resources are sufficient to accomplish assigned tasks. C. Responsibilities and authority of each management, supervisory, and professional position are clearly defined. D. Personnel clearly understand their authority, responsibilities, accountabilities, and interfaces with supporting groups. E. Administrative controls are employed for maintenance activities important to plant safety and reliability. F. Performance appraisals are effectively utilized to enhance individual performance

  6. Evaluating Performance: Strategic Alignment and Productivity

    Directory of Open Access Journals (Sweden)

    Armando Cuesta Santos

    2012-10-01

    Full Text Available Actually is reported as a world problem to enterprise label the rupture or inexistence of the connections between the strategy, human resource management and the organizational management indicators. In the Cuban enterprise practice this is manifest too. Surpass this rupture on the technical and organizer plan, is the principal objective of this research. In this paper is argument one methodological process that begins with the definition of labour competency to consider into post profiles, that conduced to surpass the actual rupture or opposition (versus, or not alignment or not integration, between the performance individual appraisal and the performance organizational strategic appraisal.

  7. PERFORMANCE EVALUATION OF CHINESE NEW FUNDS

    Institute of Scientific and Technical Information of China (English)

    倪苏云; 翁轶丛; 吴冲锋

    2001-01-01

    he performance of Chinese investment funds was empirically analyzed using the following models, i.e. Jensen model, Treynor-Mazuy (T-M) model amd Merton-Henriksson model. The results show that T-M model is fitted to Chinese investment funds best among these three. But none of them can perfectly interpret the new funds' performance. So, the idea suggested by Jagannathan, Korajczyk (J-K) to extend the test was adopted in this paper, and the results show that J-K model augmented from the M-H can explain the source of excess return of fund Anxin.

  8. Importance Performance Analysis as a Trade Show Performance Evaluation and Benchmarking Tool

    OpenAIRE

    Tafesse, Wondwesen; Skallerud, Kåre; Korneliussen, Tor

    2010-01-01

    Author's accepted version (post-print). The purpose of this study is to introduce importance performance analysis as a trade show performance evaluation and benchmarking tool. Importance performance analysis considers exhibitors’ performance expectation and perceived performance in unison to evaluate and benchmark trade show performance. The present study uses data obtained from exhibitors of an international trade show to demonstrate how importance performance analysis can be used to eval...

  9. Experimental Adaptive Digital Performance Monitoring for Optical DP-QPSK Coherent Receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zhang, Xu; Zibar, Darko

    2011-01-01

    We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module.......We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module....

  10. Design, Construction and Performance Evaluation of Multiple ...

    African Journals Online (AJOL)

    The complex casting machine has been designed to perform the following techniques: gravity casting, stir casting, squeeze casting, vacuum casting, compocasting and thixoforming. All these casting techniques have been integrated into this complex casting machine as different units which work with the help of automation.

  11. A performance evaluation of point pair features

    DEFF Research Database (Denmark)

    Kiforenko, Lilita; Drost, Bertram; Tombari, Federico

    2018-01-01

    have low resolution data, where local histogram features show a higher performance than PPFs. We also found that PPFs compared to most local histogram features degrade faster under disturbances such as occlusion and clutter, however, PPFs still remain more descriptive on an absolute scale. The main...

  12. Performance evaluation of chip seals in Idaho.

    Science.gov (United States)

    2010-08-01

    The intent of this research project is to identify a wide variety of parameters that influence the performance of pavements treated via chip seals within the State of Idaho. Chip sealing is currently one of the most popular methods of maintenance for...

  13. Performance evaluation of prototype mechanical cassava harvester ...

    African Journals Online (AJOL)

    Large-scale cassava harvesting, especially during the dry season, is a major constraint to its industrial demand and commercial production. Manual harvesting is slow and ... Results from field trials showed prototype harvesters weighing 268 – 310 kg can achieve optimum performance on ridged landforms. When harvested ...

  14. Space Shuttle Underside Astronaut Communications Performance Evaluation

    Science.gov (United States)

    Hwu, Shian U.; Dobbins, Justin A.; Loh, Yin-Chung; Kroll, Quin D.; Sham, Catherine C.

    2005-01-01

    The Space Shuttle Ultra High Frequency (UHF) communications system is planned to provide Radio Frequency (RF) coverage for astronauts working underside of the Space Shuttle Orbiter (SSO) for thermal tile inspection and repairing. This study is to assess the Space Shuttle UHF communication performance for astronauts in the shadow region without line-of-sight (LOS) to the Space Shuttle and Space Station UHF antennas. To insure the RF coverage performance at anticipated astronaut worksites, the link margin between the UHF antennas and Extravehicular Activity (EVA) Astronauts with significant vehicle structure blockage was analyzed. A series of near-field measurements were performed using the NASA/JSC Anechoic Chamber Antenna test facilities. Computational investigations were also performed using the electromagnetic modeling techniques. The computer simulation tool based on the Geometrical Theory of Diffraction (GTD) was used to compute the signal strengths. The signal strength was obtained by computing the reflected and diffracted fields along the propagation paths between the transmitting and receiving antennas. Based on the results obtained in this study, RF coverage for UHF communication links was determined for the anticipated astronaut worksite in the shadow region underneath the Space Shuttle.

  15. Game Performance Evaluation in Male Goalball Players

    Science.gov (United States)

    Molik, Bartosz; Morgulec-Adamowicz, Natalia; Kosmol, Andrzej; Perkowski, Krzysztof; Bednarczuk, Grzegorz; Skowroński, Waldemar; Gomez, Miguel Angel; Koc, Krzysztof; Rutkowska, Izabela; Szyman, Robert J

    2015-01-01

    Goalball is a Paralympic sport exclusively for athletes who are visually impaired and blind. The aims of this study were twofold: to describe game performance of elite male goalball players based upon the degree of visual impairment, and to determine if game performance was related to anthropometric characteristics of elite male goalball players. The study sample consisted of 44 male goalball athletes. A total of 38 games were recorded during the Summer Paralympic Games in London 2012. Observations were reported using the Game Efficiency Sheet for Goalball. Additional anthropometric measurements included body mass (kg), body height (cm), the arm span (cm) and length of the body in the defensive position (cm). The results differentiating both groups showed that the players with total blindness obtained higher means than the players with visual impairment for game indicators such as the sum of defense (p = 0.03) and the sum of good defense (p = 0.04). The players with visual impairment obtained higher results than those with total blindness for attack efficiency (p = 0.04), the sum of penalty defenses (p = 0.01), and fouls (p = 0.01). The study showed that athletes with blindness demonstrated higher game performance in defence. However, athletes with visual impairment presented higher efficiency in offensive actions. The analyses confirmed that body mass, body height, the arm span and length of the body in the defensive position did not differentiate players’ performance at the elite level. PMID:26834872

  16. Game Performance Evaluation in Male Goalball Players

    Directory of Open Access Journals (Sweden)

    Molik Bartosz

    2015-12-01

    Full Text Available Goalball is a Paralympic sport exclusively for athletes who are visually impaired and blind. The aims of this study were twofold: to describe game performance of elite male goalball players based upon the degree of visual impairment, and to determine if game performance was related to anthropometric characteristics of elite male goalball players. The study sample consisted of 44 male goalball athletes. A total of 38 games were recorded during the Summer Paralympic Games in London 2012. Observations were reported using the Game Efficiency Sheet for Goalball. Additional anthropometric measurements included body mass (kg, body height (cm, the arm span (cm and length of the body in the defensive position (cm. The results differentiating both groups showed that the players with total blindness obtained higher means than the players with visual impairment for game indicators such as the sum of defense (p = 0.03 and the sum of good defense (p = 0.04. The players with visual impairment obtained higher results than those with total blindness for attack efficiency (p = 0.04, the sum of penalty defenses (p = 0.01, and fouls (p = 0.01. The study showed that athletes with blindness demonstrated higher game performance in defence. However, athletes with visual impairment presented higher efficiency in offensive actions. The analyses confirmed that body mass, body height, the arm span and length of the body in the defensive position did not differentiate players’ performance at the elite level.

  17. Using Ratio Analysis to Evaluate Financial Performance.

    Science.gov (United States)

    Minter, John; And Others

    1982-01-01

    The ways in which ratio analysis can help in long-range planning, budgeting, and asset management to strengthen financial performance and help avoid financial difficulties are explained. Types of ratios considered include balance sheet ratios, net operating ratios, and contribution and demand ratios. (MSE)

  18. 40 CFR 35.115 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.115 Section 35.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional Administrator will...

  19. 40 CFR 35.515 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.515 Section 35.515 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....515 Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional...

  20. Evaluating Suit Fit Using Performance Degradation

    Science.gov (United States)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2011-01-01

    The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

  1. Multi-Institutional Development of a Mastoidectomy Performance Evaluation Instrument.

    Science.gov (United States)

    Kerwin, Thomas; Hittle, Brad; Stredney, Don; De Boeck, Paul; Wiet, Gregory

    A method for rating surgical performance of a mastoidectomy procedure that is shown to apply universally across teaching institutions has not yet been devised. This work describes the development of a rating instrument created from a multi-institutional consortium. Using a participatory design and a modified Delphi approach, a multi-institutional group of expert otologists constructed a 15-element task-based checklist for evaluating mastoidectomy performance. This instrument was further refined into a 14-element checklist focusing on the concept of safety after using it to rate a large and varied population of performances. Twelve otolaryngological surgical training programs in the United States. A total of 14 surgeons from 12 different institutions took part in the construction of the instrument. By using 14 experts from 12 different institutions and a literature review, individual metrics were identified, rated as to the level of importance and operationally defined to create a rating scale for mastoidectomy performance. Initial use of the rating scale showed modest rater agreement. The operational definitions of individual metrics were modified to emphasize "safe" as opposed to "proper" technique. A second rating instrument was developed based on this feedback. Using a consensus-building approach with multiple rounds of communication between experts is a feasible way to construct a rating instrument for mastoidectomy. Expert opinion alone using a Delphi method provides face and content validity evidence, however, this is not sufficient to develop a universally acceptable rating instrument. A continued process of development and experimentation to demonstrate evidence for reliability and validity making use of a large population of raters and performances is necessary to achieve universal acceptance. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. Fuel performance evaluation through iodine activity monitoring

    International Nuclear Information System (INIS)

    Anantharaman, K.; Chandra, R.

    1995-01-01

    The objective of the failed fuel detection system is to keep a watch on fuel behaviour during operation. This paper describes the evaluation of fuel behaviour by monitoring the activities of various isotopes of iodine both during steady state and during a reactor shutdown. The limitations of this approach also has been explained. The monitoring of tramp uranium for different types of release, namely fixed contamination and continuous release from fuel, is also presented. (author)

  3. Evaluation of new reference genes in papaya for accurate transcript normalization under different experimental conditions.

    Directory of Open Access Journals (Sweden)

    Xiaoyang Zhu

    Full Text Available Real-time reverse transcription PCR (RT-qPCR is a preferred method for rapid and accurate quantification of gene expression studies. Appropriate application of RT-qPCR requires accurate normalization though the use of reference genes. As no single reference gene is universally suitable for all experiments, thus reference gene(s validation under different experimental conditions is crucial for RT-qPCR analysis. To date, only a few studies on reference genes have been done in other plants but none in papaya. In the present work, we selected 21 candidate reference genes, and evaluated their expression stability in 246 papaya fruit samples using three algorithms, geNorm, NormFinder and RefFinder. The samples consisted of 13 sets collected under different experimental conditions, including various tissues, different storage temperatures, different cultivars, developmental stages, postharvest ripening, modified atmosphere packaging, 1-methylcyclopropene (1-MCP treatment, hot water treatment, biotic stress and hormone treatment. Our results demonstrated that expression stability varied greatly between reference genes and that different suitable reference gene(s or combination of reference genes for normalization should be validated according to the experimental conditions. In general, the internal reference genes EIF (Eukaryotic initiation factor 4A, TBP1 (TATA binding protein 1 and TBP2 (TATA binding protein 2 genes had a good performance under most experimental conditions, whereas the most widely present used reference genes, ACTIN (Actin 2, 18S rRNA (18S ribosomal RNA and GAPDH (Glyceraldehyde-3-phosphate dehydrogenase were not suitable in many experimental conditions. In addition, two commonly used programs, geNorm and Normfinder, were proved sufficient for the validation. This work provides the first systematic analysis for the selection of superior reference genes for accurate transcript normalization in papaya under different experimental

  4. 48 CFR 1552.209-76 - Contractor performance evaluations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Contractor performance... 1552.209-76 Contractor performance evaluations. As prescribed in section 1509.170-1, insert the following clause in all applicable solicitations and contracts. Contractor Performance Evaluations (OCT 2002...

  5. 48 CFR 8.406-7 - Contractor Performance Evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contractor Performance... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Federal Supply Schedules 8.406-7 Contractor Performance Evaluation. Ordering activities must prepare an evaluation of contractor performance for each...

  6. 48 CFR 1536.201 - Evaluation of contracting performance.

    Science.gov (United States)

    2010-10-01

    ... performance. 1536.201 Section 1536.201 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY... Contracting for Construction 1536.201 Evaluation of contracting performance. (a) The Contracting Officer will... will file the form in the contractor performance evaluation files which it maintains. (e) The Quality...

  7. Experimental evaluation of mechanical heart support system based on viscous friction disc pump

    Directory of Open Access Journals (Sweden)

    A. M. Chernyavskiy

    2017-01-01

    Full Text Available Aim. Experimental evaluation of the viscous friction disk pump efficiency, studying the relationship between inter-disk clearance and sizes of input and output ports and pump performance parameters.Materials and methods. To assess the characteristics and to optimize the disk friction pump design the pump model and experimental stand were created. Pump dimensions were set on the basis of medical and biological requirements for mechanical heart support systems and with due consideration of the experimental studies of our colleagues from Pennsylvania. Flow volume of the working fluid was measured by float rotameter Krohne VA-40 with measurement error of not more than 1%. The pressure values in the hydrodynamic circuit were measured using a monitor manufactured by Biosoft-M. Expansion device allowed changing the flow resistance of the system simulating the total peripheral resistance of the circulatory system.Results. Linear direct correlation between the pump performance and the pressure drop of liquid being created at the inlet and outlet of the pump was obtained. The required flow rate (5–7 l/min and pressure (90–100 mmHg were reached when the rotor speed was in the range of 2500–3000 rev/min. It has been shown that the increase of the inlet diameter to 15 mm has not resulted in a significant increase in the pump performance, and that the highest efficiency values can be obtained for the magnitude of inter-disk gap of 0.4–0.5 mm.Conclusion. Designed and manufactured experimental disc pump model for pumping fluid has showed the fundamental possibility to use this model as a system for mechanical support of the heart.

  8. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  9. Diagnostics and performance evaluation of multikilohertz capacitors

    International Nuclear Information System (INIS)

    McDuff, G.; Nunnally, W.C.; Rust, K.; Sarjeant, J.

    1980-01-01

    The observed performance of nanofarad polypropylene-silicone oil, mica paper, and polytetrafluoroethylene-silicone oil capacitors discharged in a 100-ns, 1-kA pulse with a pulse repetition frequency of 1 kHz is presented. The test facility circuit, diagnostic parameters, and the preliminary test schedule are outlined as a basis for discussion of the observed failure locations and proposed failure mechanisms. Most of the test data and discussion presented involves the polypropylene-silicone oil units

  10. Attributes and descriptors for building performance evaluation

    Directory of Open Access Journals (Sweden)

    S. Gopikrishnan

    2017-12-01

    In order to obtain the right feedback in levels of satisfaction with respect to these attributes, there is a need to have appropriate descriptors for incorporation in a survey instrument. This paper identifies attributes that indicate building performance and provides simple description of these attributes based on which items can be generated for a questionnaire. Such items can enable any user/occupant to easily understand the characteristics of these attributes and offer an objective feedback during questionnaire survey.

  11. Brookfield Homes Passive House Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-01

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction.

  12. Evaluating performance measures to determine training effectiveness

    International Nuclear Information System (INIS)

    Klemm, R.W.; Feiza, A.S.

    1987-01-01

    This research was conceived and dedicated to helping the CECo training organization become a more integrated part of the corporate business. The target population for this study was nuclear and fossil generating station employees who directly impacted the production of electricity. The target sample (n = 150) included: instrument, mechanical, and electrical maintenance personnel; control room operators; engineers, radiation chemists, and other technical specialists; and equipment operators and attendants. A total of four instruments were utilized by this study. Three instruments were administered to the generating station personnel. These included a demographic form, a learning style profile, and a motivational style profile. The focal instrument, a performance skills rating form, was administered to supervisory personnel. Data analysis consisted of three major parts. Part one established internal consistency through Cronbach alpha statistics. Part two provides summary statistics and breakdown tables for important variables. Part three provides inferential statistics responding to the research questions. All six Performance Skills variables discriminated significantly between the trained and non-trained groups (p .001). In all cases, the mean value for the trained group exceeded the mean value for the non-trained group. Implications for further research indicate that training does have a quantifiable effect on job performance

  13. Experimental evaluation of a modal parameter based system identification procedure

    Science.gov (United States)

    Yu, Minli; Feng, Ningsheng; Hahn, Eric J.

    2016-02-01

    Correct modelling of the foundation of a rotor bearing foundation system (RBFS) is an invaluable asset for the balancing and efficient running of turbomachinery. Numerical experiments have shown that a modal parameter based identification approach could be feasible for this purpose but there is a lack of experimental verification of the suitability of such a modal approach for even the simplest systems. In this paper the approach is tested on a simple experimental rig comprising a clamped horizontal bar with lumped masses. It is shown that apart from damping, the proposed approach can identify reasonably accurately the relevant modal parameters of the rig; and that the resulting equivalent system can predict reasonably well the frequency response of the rig. Hence, the proposed approach shows promise but further testing is required, since application to identifying the foundation of an RBFS involves the additional problem of accurately obtaining the force excitation from motion measurements.

  14. EXPERIMENTAL EVALUATION OF ARTICULATED WHEELED VEHICLES POSITION STABILITY

    Directory of Open Access Journals (Sweden)

    Ye. Dubinin

    2015-07-01

    Full Text Available With introducing a mobile measurement system with linear acceleration sensors there was experimentally determined the parameter of position stability of the articulated wheeled vehicle on the example of HTA-200 «Slobozhanets». It was determined that the position stability was provided within the entire range of operating speeds and accelerations. The obtained results can be used to enhance the traffic safety of articulated vehicles.

  15. Experimental evaluation of voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, a method for voltage unbalance compensation in an islanded microgrid based on the proper control of distributed generators (DGs) interface converter is proposed. In this method, active and reactive power control loops are considered to control the power sharing among the DGs. Also......, a virtual impedance loop and voltage and current proportional-resonant controllers are included. Experimental results show the effectiveness of the proposed method for compensating voltage unbalance to an acceptable level....

  16. A comprehensive toxicological evaluation of three adhesives using experimental cigarettes.

    Science.gov (United States)

    Coggins, Christopher R E; Jerome, Ann M; Lilly, Patrick D; McKinney, Willie J; Oldham, Michael J

    2013-01-01

    Adhesives are used in several different manufacturing operations in the production of cigarettes. The use of new, "high-speed-manufacture" adhesives (e.g. vinyl acetate based) could affect the smoke chemistry and toxicology of cigarettes, compared with older "low-speed-manufacture" adhesives (e.g. starch based). This study was conducted to determine whether the inclusion of different levels of three adhesives (ethylene vinyl acetate, polyvinyl acetate and starch) in experimental cigarettes results in different smoke chemistry and toxicological responses in in vitro and in vivo assays. A battery of tests (analytical chemistry, in vitro and in vivo assays) was used to compare the chemistry and toxicology of smoke from experimental cigarettes made with different combinations of the three adhesives. Varying levels of the different side-seam adhesives, as well as the transfer of adhesives from packaging materials, were tested. There were differences in some mainstream cigarette smoke constituents as a function of the level of adhesive added to experimental cigarettes and between the tested adhesives. None of these differences translated into statistically significant differences in the in vitro or in vivo assays. The use of newer "high-speed-manufacture" vinyl acetate-based adhesives in cigarettes does not produce toxicological profiles that prevent the adhesives from replacing the older "low-speed-manufacture" adhesives (such as starch).

  17. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  18. Experimental evaluation of ontology-based HIV/AIDS frequently asked question retrieval system.

    Science.gov (United States)

    Ayalew, Yirsaw; Moeng, Barbara; Mosweunyane, Gontlafetse

    2018-05-01

    This study presents the results of experimental evaluations of an ontology-based frequently asked question retrieval system in the domain of HIV and AIDS. The main purpose of the system is to provide answers to questions on HIV/AIDS using ontology. To evaluate the effectiveness of the frequently asked question retrieval system, we conducted two experiments. The first experiment focused on the evaluation of the quality of the ontology we developed using the OQuaRE evaluation framework which is based on software quality metrics and metrics designed for ontology quality evaluation. The second experiment focused on evaluating the effectiveness of the ontology in retrieving relevant answers. For this we used an open-source information retrieval platform, Terrier, with retrieval models BM25 and PL2. For the measurement of performance, we used the measures mean average precision, mean reciprocal rank, and precision at 5. The results suggest that frequently asked question retrieval with ontology is more effective than frequently asked question retrieval without ontology in the domain of HIV/AIDS.

  19. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The Captive Helicopter as a Training Device: Experimental Evaluation of a Concept. Technical Report 68-9.

    Science.gov (United States)

    Caro, Paul W., Jr.; And Others

    As part of the Army's effort to use synthetic devices to improve training, researchers evaluated a captive helicopter attached to a ground effects machine. Experimental groups received varying amounts of pre-flight practice tasks designed to develop flight skills, while control groups received no device training. Student flight performance during…

  1. Comparative performance of three experimental hut designs for measuring malaria vector responses to insecticides in Tanzania.

    Science.gov (United States)

    Massue, Dennis J; Kisinza, William N; Malongo, Bernard B; Mgaya, Charles S; Bradley, John; Moore, Jason D; Tenu, Filemoni F; Moore, Sarah J

    2016-03-15

    Experimental huts are simplified, standardized representations of human habitations that provide model systems to evaluate insecticides used in indoor residual spray (IRS) and long-lasting insecticidal nets (LLINs) to kill disease vectors. Hut volume, construction materials and size of entry points impact mosquito entry and exposure to insecticides. The performance of three standard experimental hut designs was compared to evaluate insecticide used in LLINs. Field studies were conducted at the World Health Organization Pesticide Evaluation Scheme (WHOPES) testing site in Muheza, Tanzania. Three East African huts, three West African huts, and three Ifakara huts were compared using Olyset(®) and Permanet 2.0(®) versus untreated nets as a control. Outcomes measured were mortality, induced exophily (exit rate), blood feeding inhibition and deterrence (entry rate). Data were analysed using linear mixed effect regression and Bland-Altman comparison of paired differences. A total of 613 mosquitoes were collected in 36 nights, of which 13.5% were Anopheles gambiae sensu lato, 21% Anopheles funestus sensu stricto, 38% Mansonia species and 28% Culex species. Ifakara huts caught three times more mosquitoes than the East African and West African huts, while the West African huts caught significantly fewer mosquitoes than the other hut types. Mosquito densities were low, very little mosquito exit was measured in any of the huts with no measurable exophily caused by the use of either Olyset or Permanet. When the huts were directly compared, the West African huts measured greater exophily than other huts. As unholed nets were used in the experiments and few mosquitoes were captured, it was not possible to measure difference in feeding success either between treatments or hut types. In each of the hut types there was increased mortality when Permanet or Olyset were present inside the huts compared to the control, however this did not vary between the hut types. Both East African

  2. Performance evaluation of PCA-based spike sorting algorithms.

    Science.gov (United States)

    Adamos, Dimitrios A; Kosmidis, Efstratios K; Theophilidis, George

    2008-09-01

    Deciphering the electrical activity of individual neurons from multi-unit noisy recordings is critical for understanding complex neural systems. A widely used spike sorting algorithm is being evaluated for single-electrode nerve trunk recordings. The algorithm is based on principal component analysis (PCA) for spike feature extraction. In the neuroscience literature it is generally assumed that the use of the first two or most commonly three principal components is sufficient. We estimate the optimum PCA-based feature space by evaluating the algorithm's performance on simulated series of action potentials. A number of modifications are made to the open source nev2lkit software to enable systematic investigation of the parameter space. We introduce a new metric to define clustering error considering over-clustering more favorable than under-clustering as proposed by experimentalists for our data. Both the program patch and the metric are available online. Correlated and white Gaussian noise processes are superimposed to account for biological and artificial jitter in the recordings. We report that the employment of more than three principal components is in general beneficial for all noise cases considered. Finally, we apply our results to experimental data and verify that the sorting process with four principal components is in agreement with a panel of electrophysiology experts.

  3. Performance evaluation of a distance learning program.

    OpenAIRE

    Dailey, D. J.; Eno, K. R.; Brinkley, J. F.

    1994-01-01

    This paper presents a performance metric which uses a single number to characterize the response time for a non-deterministic client-server application operating over the Internet. When applied to a Macintosh-based distance learning application called the Digital Anatomist Browser, the metric allowed us to observe that "A typical student doing a typical mix of Browser commands on a typical data set will experience the same delay if they use a slow Macintosh on a local network or a fast Macint...

  4. HENC performance evaluation and plutonium calibration

    International Nuclear Information System (INIS)

    Menlove, H.O.; Baca, J.; Pecos, J.M.; Davidson, D.R.; McElroy, R.D.; Brochu, D.B.

    1997-10-01

    The authors have designed a high-efficiency neutron counter (HENC) to increase the plutonium content in 200-L waste drums. The counter uses totals neutron counting, coincidence counting, and multiplicity counting to determine the plutonium mass. The HENC was developed as part of a Cooperative Research and Development Agreement between the Department of Energy and Canberra Industries. This report presents the results of the detector modifications, the performance tests, the add-a-source calibration, and the plutonium calibration at Los Alamos National Laboratory (TA-35) in 1996

  5. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. This implicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes...

  6. Performance evaluation of seal coat materials and designs.

    Science.gov (United States)

    2011-01-01

    "This project presents an evaluation of seal coat materials and design method. The primary objectives of this research are 1) to evaluate seal coat performance : from various combinations of aggregates and emulsions in terms of aggregate loss; 2) to ...

  7. Diverging diamond interchange performance evaluation (I-44 and Route 13)

    Science.gov (United States)

    2011-02-01

    Performance evaluation was conducted on the first diverging diamond interchange (DDI) or double : crossover interchange (DCD) constructed in the United States. This evaluation assessed traffic operations, safety and : public perceptions t...

  8. Quasi-Experimental Evaluation of a Student Mentoring Program

    OpenAIRE

    Sandner, Malte

    2013-01-01

    This paper presents evidence from a natural-experiment which evaluates the effectiveness of a student mentoring program. The mentoring includes several compulsory, scheduled, faceto- face appointments between a mentor and a student in the first study year. All mentors are graduated and employed by the institution. For the evaluation, I use the fact that the mentoring is only offered to students in an economics and management program, whereas it is not offered to students in an industrial engi...

  9. Brazilian Resorts: an overall performance evaluation

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Bonfato

    2016-05-01

    Full Text Available This scientific article is about resort’s operations in Brazil. The main goal was to identify the financial key performance indicators, so that it could contribute to a better comprehension about how the resorts area acts in Brazil. To achieve this goal, this study took researches which generated numbers and indicators that could establish a comparison between 2013 and 2014. The main sources were token from all resorts from the Associação Brasileira de Resorts - Resorts Brasil, as well as an interview with a renowned area professional. Other sources were token by the most important resorts books. There are actually 49 resorts which are part of the Brazilian Resorts Association-ABR/Resorts Brasil. This institution allowed the access to all its database, in which the associated resorts give numerical informations about its own performance. The resorts studied in this article were divided and studied in four big groups. The results showed that the national resorts market keeps increasing its statistics and improving its internal management processes and sales distribution. Revenues increased 6.34% in the main analysed indicator during the years of 2013 and 2014. It was also observed that beach and all inclusive resorts tend to have better results.

  10. Experimental study on the thrust modulation performance of powdered magnesium and CO2 bipropellant engine

    Science.gov (United States)

    Li, Chao; Hu, Chunbo; Zhu, Xiaofei; Hu, Jiaming; Li, Yue; Hu, Xu

    2018-06-01

    Powdered Mg and CO2 bipropellant engine providing a practical demonstration of in situ resource utilization (ISRU) for Mars Sample Return (MSR) mission seems to be feasible by current investigations. However, essential functions of the engine to satisfy the complicated ballistics requirements such as thrust modulation and multiple pulse have not been established yet. The aim of this experimental study is to evaluate the engine's thrust modulation feasibility and to investigate its thrust modulation characteristics. A powdered Mg and CO2 bipropellant engine construction aiming to achieve thrust modulation ability was proposed. A mass flow rate calibration experiment to evaluate the gas-solid mass flow rate regulating performance was conducted before fire tests. Fire test result shows that the engine achieved successful ignition as well as self-sustaining combustion; Thrust modulation of the engine is feasible, detail thrust estimating result of the test shows that maximum thrust is 135.91 N and the minimum is 5.65 N with a 22.11 thrust modulation ratio, moreover, the transportation period is quick and the thrust modulation ratio is adjustable. At the same time, the powder feed system reaches a two-step flow rate regulating with a modulation ratio of 4.5-5. What' more, caused by the uneven engine working conditions, there is an obvious difference in combustion efficiency value, maximum combustion efficiency of the powdered Mg and CO2 bipropellant engine is 80.20%.

  11. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed; Hendam, Ahmed; Fahmy, Ezzat; Abou Zeid, Mohamed; Haroun, Medhat

    2012-01-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  12. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed

    2012-05-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  13. An Analytical Hierarchy Process Model for the Evaluation of College Experimental Teaching Quality

    Science.gov (United States)

    Yin, Qingli

    2013-01-01

    Taking into account the characteristics of college experimental teaching, through investigaton and analysis, evaluation indices and an Analytical Hierarchy Process (AHP) model of experimental teaching quality have been established following the analytical hierarchy process method, and the evaluation indices have been given reasonable weights. An…

  14. The Nonuse, Misuse, and Proper Use of Pilot Studies in Experimental Evaluation Research

    Science.gov (United States)

    Westlund, Erik; Stuart, Elizabeth A.

    2017-01-01

    This article discusses the nonuse, misuse, and proper use of pilot studies in experimental evaluation research. The authors first show that there is little theoretical, practical, or empirical guidance available to researchers who seek to incorporate pilot studies into experimental evaluation research designs. The authors then discuss how pilot…

  15. Experimental Evaluation of the Training Structure of the Picture Exchange Communication System (PECS)

    Science.gov (United States)

    Cummings, Anne R.; Carr, James E.; LeBlanc, Linda A.

    2012-01-01

    The Picture Exchange Communication System (PECS) is a picture-based alternative communication method that is widely accepted and utilized with individuals with disabilities. Although prior studies have examined the clinical efficacy of PECS, none have experimentally evaluated its manualized training structure. We experimentally evaluated the…

  16. Burar seismic station: evaluation of seismic performance

    International Nuclear Information System (INIS)

    Ghica, Daniela; Popa, Mihaela

    2005-01-01

    A new seismic monitoring system, the Bucovina Seismic Array (BURAR), has been established since July 2002, in the Northern part of Romania, in a joint effort of the Air Force Technical Applications Center, USA, and the National Institute for Earth Physics (NIEP), Romania. The small-aperture array consists of 10 seismic sensors (9 vertical short-period and one three-component broad band) located in boreholes and distributed in a 5 x 5 km 2 area. At present, the seismic data are continuously recorded by the BURAR and transmitted in real-time to the Romanian National Data Center in Bucharest and National Data Center of the USA, in Florida. Based on the BURAR seismic information gathered at the National Data Center, NIEP (ROM N DC), in the August 2002 - December 2004 time interval, analysis and statistical assessments were performed. Following the preliminary processing of the data, several observations on the global performance of the BURAR system were emphasized. Data investigation showed an excellent efficiency of the BURAR system particularly in detecting teleseismic and regional events. Also, a statistical analysis for the BURAR detection capability of the local Vrancea events was performed in terms of depth and magnitude for the year 2004. The high signal detection capability of the BURAR resulted, generally, in improving the location solutions for the Vrancea seismic events. The location solution accuracy is enhanced when adding BURAR recordings, especially in the case of low magnitude events (recorded by few stations). The location accuracy is increased, both in terms of constraining hypocenter depth and epicentral coordinates. Our analysis certifies the importance of the BURAR system in NIEP efforts to elaborate seismic bulletins. Furthermore, the specific procedures for array data processing (beam forming, f-k analysis) increase significantly the signal-to-noise ratio by summing up the coherent signals from the array components, and ensure a better accuracy

  17. performance evaluation of a pilot paraplegic centricity mobility aid

    African Journals Online (AJOL)

    eobe

    PERFORMANCE EVALUATION OF A PILOT PARAPLEGIC CENTRICITY. MOBILITY AID. MOBILITY ... The result of the test showed a remarkable improvement in. Wilcoxin's signed rank test. .... RESEARCH METHOD. RESEARCH METHOD.

  18. performance evaluation of sprinkler irrigation system at mambilla

    African Journals Online (AJOL)

    HOD

    ratio (DPR), irrigation productivity (IP), labour requirements and water quality. Standard procedure was ... The exchangeable cations analysis of Kakara irrigation ... Keywords: Tea, irrigation System, Performance Evaluation. 1. INTRODUCTION.

  19. An hierarchical approach to performance evaluation of expert systems

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Kavi, Srinu

    1985-01-01

    The number and size of expert systems is growing rapidly. Formal evaluation of these systems - which is not performed for many systems - increases the acceptability by the user community and hence their success. Hierarchical evaluation that had been conducted for computer systems is applied for expert system performance evaluation. Expert systems are also evaluated by treating them as software systems (or programs). This paper reports many of the basic concepts and ideas in the Performance Evaluation of Expert Systems Study being conducted at the University of Southwestern Louisiana.

  20. Investigation of the existence of self compacting properties in high performance concrete through experimental tests

    Directory of Open Access Journals (Sweden)

    Heitor H. Yoshida

    2007-03-01

    Full Text Available The self compacting concrete is characterized by its capacity to flow inside the formwork filling it exclusively by the force of the gravity with adequate cohesion and viscosity in such a way that segregation does not occur. One of its characteristic is the presence of fines which provide the necessary cohesion,and grains with maximum diameter of 20 mm. This work presents some procedures and experimental methods that make it possible to evaluate self compacting properties of high performance concrete. First, a bibliographical review on the subject was carried out, and later, the equipment used for the accomplishment of the assays were manufactured, in order to verify the properties related to the self compacting concrete: cohesion, viscosity and segregation. As for the work, two concretes were produced with Portland ARI Cement, thick sand, stone powder, sand 0, superplasticizer made of ether-carboxilate chains that differentiate from each other for the presence of active silica in one of them and fly ash in the other. Based on the results, it was verified whether the high performance concrete had self compacting characteristics. In this case, both were considered positive. It was also analyzed the behavior of these concretes in their hardened state by means of the compressive strength test. The Self Compacting Concrete has many advantages such as: reduction in the number of employees, shorter construction period, the non-use of the vibrator and the filling of formworks with high density of… or of complex geometry.

  1. An Integrated Numerical and Experimental Analysis for Enhancing the Performance of the Hidden Ceiling Fan

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2014-02-01

    Full Text Available Since the inlet and outlet of hidden ceiling fan are almost located at the same Plane; thus, an improper housing may cause inhale-return phenomenon which significantly affects its power consumption and performance. In this study, a comprehensive investigation by numerical and experimental techniques was used to predict and identify the flow pattern, airflow rate, efficiency, and noise for ceiling fans with different design parameters. The results showed that the unique inhale-return phenomenon happens for an inappropriate housing. Several key parameters, such as fan guard, housing ring, inlet-to-outlet area ratio, and blockage height, are evaluated for finding out the criterion to avoid the inhale-return flow. Consequently the study finds that fan guard changes the airflow to a wider distribution with a lower velocity. A minimum blockage distance and a maximum height of ring-plate are set at 80 mm and 30 mm, respectively. Also, it is suggested that the inlet area must be bigger than the outlet area. Moreover, all the parameters show the same trend under various rotational speeds. In conclusion, this systematic investigation not only provides the fan engineer's design ability to avoid the inhale-return phenomenon, but also the predicting capability on its aerodynamic and acoustic performances.

  2. Evaluation of teachers' performance of vision screening in primary

    African Journals Online (AJOL)

    Dr. Petronilla

    Evaluation of Teachers' Performance of Vision Screening in Primary. School Children in Port ... teachers can effectively perform vision screening in school children using ..... may be due to variations in methodology and definitions used, as this ...

  3. PERFORMANCE EVALUATION OF TYPE I MARINE SANITATION DEVICES

    Science.gov (United States)

    This performance test was designed to evaluate the effectiveness of two Type I Marine Sanitation Devices (MSDs): the Electro Scan Model EST 12, manufactured by Raritan Engineering Company, Inc., and the Thermopure-2, manufactured by Gross Mechanical Laboratories, Inc. Performance...

  4. Evaluation of performance of extension workers in Lesotho | Mokone ...

    African Journals Online (AJOL)

    Evaluation of performance of extension workers in Lesotho. ... role to play in ensuring that extension workers improve their work performance and as ... This cannot be true since most of the factors that affect efficiency were found to be negative.

  5. Performance evaluation of a distance learning program.

    Science.gov (United States)

    Dailey, D J; Eno, K R; Brinkley, J F

    1994-01-01

    This paper presents a performance metric which uses a single number to characterize the response time for a non-deterministic client-server application operating over the Internet. When applied to a Macintosh-based distance learning application called the Digital Anatomist Browser, the metric allowed us to observe that "A typical student doing a typical mix of Browser commands on a typical data set will experience the same delay if they use a slow Macintosh on a local network or a fast Macintosh on the other side of the country accessing the data over the Internet." The methodology presented is applicable to other client-server applications that are rapidly appearing on the Internet.

  6. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into waveenergy has been undertaken for decades, a significant increase in related activities has been seen in the recent years......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes....... Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. Thisimplicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...

  7. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  8. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  9. Duty cycle testing and performance evaluation of the SM-229 teleoperator

    International Nuclear Information System (INIS)

    Stoughton, R.S.; Kuban, D.P.

    1985-11-01

    This paper contains the first known experimental studies and analyses of teleoperator performance for specific duty cycles. The results are presented in two distinct areas as position usage patterns, and as three-dimensional power grids. The position usage patterns are a valuable means to assess the available motion range. The power grids are a unique concept for evaluating joint performance. Final conclusions contain recommendations to upgrade the teleoperator for optimum performance. 3 refs., 16 figs

  10. An experimental investigation on relationship between PSFs and operator performances in the digital main control room

    International Nuclear Information System (INIS)

    Park, Jooyoung; Lee, Daeil; Jung, Wondea; Kim, Jonghyun

    2017-01-01

    Highlights: • The relationship between performance shaping factors and operator performances are experimentally investigated. • The experiment includes features of digital main control room. • The result indicates that the operator’s experience level is the most effective on the performance. - Abstract: This study designs an experiment to investigate the relationship between performance shaping factors (PSFs) and operator performances. This study involves selecting three PSFs that are controllable in the experiments: (1) experience, (2) complexity, and (3) urgency. Six scenarios are developed to reflect the PSFs. The experiment involves the participation of licensed operators and the use of an APR1400 simulator. During the experiment, operator performances, such as completion time, error, secondary task, workload, and situation awareness, are measured and collected. The experimental result indicates that the operator’s experience is most effective on the overall performances. The task complexity influences the secondary tasks and situation awareness.

  11. EVALUATION OF THE FINANCIAL PERFORMANCE OF PENSION FUNDS IN CROATIA

    OpenAIRE

    Dražen Novaković

    2015-01-01

    The aim of this paper is to evaluate the financial performance of pension funds in Croatia. Although there are other factors which are important in the pension funds overall performance, this paper focuses on investment accomplishments. The purpose of measuring portfolio performance is to determine whether portfolio managers add value compared to passive investment strategies. The traditional approach to pension funds’ performance evaluation underlines standard measures of financial performan...

  12. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    Science.gov (United States)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  13. Relationship between kinesiophobia and performance in a functional capacity evaluation

    NARCIS (Netherlands)

    Reneman, MF; Jorritsma, W; Dijkstra, SJ; Dijkstra, PU

    2003-01-01

    Fear of movement and (re) injury (kinesiophobia) has been postulated to play an important role in the performance in a Functional Capacity Evaluation (FCE). This study was performed to analyze the relationship between kinesiophobia and performance in an FCE. Kinesiophobia and FCE performance of 54

  14. Experimental evaluation of pumpjet propulsor for an axisymmetric body in wind tunnel

    Directory of Open Access Journals (Sweden)

    Ch. Suryanarayana

    2010-03-01

    Full Text Available Design of a Pump Jet Propulsor (PJP was undertaken for an underwater body with axisymmetric configuration using axial flow compressor design techniques supported by Computational Fluid Dynamics (CFD analysis for performance prediction. Experimental evaluation of the PJP was carried out through experiments in a Wind Tunnel Facility (WTF using momentum defect principle for propulsive performance prior to proceeding with extensive experimental evaluation in towing tank and cavitation tunnel. Experiments were particularly conducted with respect to Self Propulsion Point (SPP, residual torque and thrust characteristics over a range of vehicle advance ratio in order to ascertain whether sufficient thrust is developed at the design condition with least possible imbalance torque left out due to residual swirl in the slip stream. Pumpjet and body models were developed for the propulsion tests using Aluminum alloy forged material. Tests were conducted from 0 m/s to 30 m/s at four rotational speeds of the PJP. SPP was determined confirming the thrust development capability of PJP. Estimation of residual torque was carried out at SPP corresponding to speeds of 15, 20 and 25 m/s to examine the effectiveness of the stator. Estimation of thrust and residual torque was also carried out at wind speeds 0 and 6 m/s for PJP RPMs corresponding to self propulsion tests to study the propulsion characteristics during the launch of the vehicle in water where advance ratios are close to Zero. These results are essential to assess the thrust performance at very low advance ratios to accelerate the body and to control the body during initial stages. This technique has turned out to be very useful and economical method for quick assessment of overall performance of the propulsor and generation of exhaustive fluid dynamic data to validate CFD techniques employed.

  15. Combined experimental and numerical evaluation of a prototype nano-PCM enhanced wallboard

    International Nuclear Information System (INIS)

    Biswas, Kaushik; Lu, Jue; Soroushian, Parviz; Shrestha, Som

    2014-01-01

    Highlights: • Field-testing of a nano-PCM wallboard under varying weather conditions. • Numerical model validation and annual simulations of PCM wallboard performance. • Reduced cooling electricity consumption results from PCM wallboard. • PCM wallboard reduces peak cooling loads with implications on power plant capacity. • PCM performance was sensitive to building temperature set point for cooling. - Abstract: In the United States, forty-eight (48) percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change materials (PCMs) in building envelopes can enhance the energy efficiency of buildings and reduce energy consumption. Experimental testing and numerical modeling of PCM-enhanced envelope components are two important aspects of the evaluation of their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM supported by expanded graphite (interconnected) nanosheets, which are highly conductive and allow enhanced thermal storage and energy distribution. The nano-PCM is shape-stable for convenient incorporation into lightweight building components. A wall with cellulose cavity insulation and a prototype PCM-enhanced interior wallboard was built and tested in a natural exposure test (NET) facility in a hot-humid climate location. The test wall contained the PCM wallboard and a regular gypsum wallboard, for a side-by-side annual comparison study. Further, numerical modeling of the wall containing the nano-PCM wallboard was performed to determine its actual impact on wall-generated heating and cooling loads. The model was first validated using experimental data, and then used for annual simulations using typical meteorological year (TMY3) weather data. This article presents the measured performance and numerical analysis evaluating the energy-saving potential of the nano-PCM-enhanced wallboard

  16. Brookfield Homes Passive House Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-04

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction. Testing with a blower door indicated that whole-building air leakage to the outside was 324 CFM and 0.60 ACH50. The other two test homes had little short-term testing done post-construction by the local energy rater. IBACOS then monitored the energy consumption and whole-house comfort conditions of that occupied Passive House after one year of operation and compared the monitoring results to those for two other occupied test houses in the same area with similar square footage but slightly different floor plans. IBACOS also assisted the builder, Brookfield Homes, in researching design scenarios for Zero Energy Ready Home and ENERGY STAR acceptance levels. IBACOS also assisted Brookfield in conceptualizing product for Denver's Brighton Heights area. Brookfield was considering building to Zero Energy Ready Home standards in that location. IBACOS provided strategies that Brookfield may draw from in the event the builder chooses to pursue a Zero Energy Ready Home plan for that market.

  17. Performance evaluation of breast image compression techniques

    Energy Technology Data Exchange (ETDEWEB)

    Anastassopoulos, G; Lymberopoulos, D [Wire Communications Laboratory, Electrical Engineering Department, University of Patras, Greece (Greece); Panayiotakis, G; Bezerianos, A [Medical Physics Department, School of Medicine, University of Patras, Greece (Greece)

    1994-12-31

    Novel diagnosis orienting tele working systems manipulate, store, and process medical data through real time communication - conferencing schemes. One of the most important factors affecting the performance of these systems is image handling. Compression algorithms can be applied to the medical images, in order to minimize : a) the volume of data to be stored in the database, b) the demanded bandwidth from the network, c) the transmission costs, and to minimize the speed of the transmitted data. In this paper an estimation of all the factors of the process that affect the presentation of breast images is made, from the time the images are produced from a modality, till the compressed images are stored, or transmitted in a Broadband network (e.g. B-ISDN). The images used were scanned images of the TOR(MAX) Leeds breast phantom, as well as typical breast images. A comparison of seven compression techniques has been done, based on objective criteria such as Mean Square Error (MSE), resolution, contrast, etc. The user can choose the appropriate compression ratio in order to achieve the desired image quality. (authors). 12 refs, 4 figs.

  18. Performance evaluation of breast image compression techniques

    International Nuclear Information System (INIS)

    Anastassopoulos, G.; Lymberopoulos, D.; Panayiotakis, G.; Bezerianos, A.

    1994-01-01

    Novel diagnosis orienting tele working systems manipulate, store, and process medical data through real time communication - conferencing schemes. One of the most important factors affecting the performance of these systems is image handling. Compression algorithms can be applied to the medical images, in order to minimize : a) the volume of data to be stored in the database, b) the demanded bandwidth from the network, c) the transmission costs, and to minimize the speed of the transmitted data. In this paper an estimation of all the factors of the process that affect the presentation of breast images is made, from the time the images are produced from a modality, till the compressed images are stored, or transmitted in a Broadband network (e.g. B-ISDN). The images used were scanned images of the TOR(MAX) Leeds breast phantom, as well as typical breast images. A comparison of seven compression techniques has been done, based on objective criteria such as Mean Square Error (MSE), resolution, contrast, etc. The user can choose the appropriate compression ratio in order to achieve the desired image quality. (authors)

  19. Evaluation of Energy Efficiency Performance of Heated Windows

    Science.gov (United States)

    Jammulamadaka, Hari Swarup

    The study about the evaluation of the performance of the heated windows was funded by the WVU Research Office as a technical assistance award at the 2014 TransTech Energy Business Development Conference to the Green Heated Glass company/project owned by Frank Dlubak. The award supports a WVU researcher to conduct a project important for commercialization. This project was awarded to the WVU Industrial Assessment Center in 2015. The current study attempted to evaluate the performance of the heated windows by developing an experimental setup to test the window at various temperatures by varying the current input to the window. The heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel based ice packs. The other face of the window was heated by passing current at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, room and box temperature were recorded, and used to calculate the apparent R-value of the window when not being heated vs when being heated. It has been concluded from the study that the heated double pane window is more effective in reducing heat losses by as much as 50% than a non-heated double pane window, if the window temperature is maintained close to the room temperature. If the temperature of the window is much higher than the room temperature, the losses through the window appear to increase beyond that of a non-heated counterpart. The issues encountered during the current round of experiments are noted, and recommendations provided for future studies.

  20. Experimental Evaluation of Equivalent-Fluid Models for Melamine Foam

    Science.gov (United States)

    Allen, Albert R.; Schiller, Noah H.

    2016-01-01

    Melamine foam is a soft porous material commonly used in noise control applications. Many models exist to represent porous materials at various levels of fidelity. This work focuses on rigid frame equivalent fluid models, which represent the foam as a fluid with a complex speed of sound and density. There are several empirical models available to determine these frequency dependent parameters based on an estimate of the material flow resistivity. Alternatively, these properties can be experimentally educed using an impedance tube setup. Since vibroacoustic models are generally sensitive to these properties, this paper assesses the accuracy of several empirical models relative to impedance tube measurements collected with melamine foam samples. Diffuse field sound absorption measurements collected using large test articles in a laboratory are also compared with absorption predictions determined using model-based and measured foam properties. Melamine foam slabs of various thicknesses are considered.

  1. Experimental evaluation of analytical penumbra calculation model for wobbled beams

    International Nuclear Information System (INIS)

    Kohno, Ryosuke; Kanematsu, Nobuyuki; Yusa, Ken; Kanai, Tatsuaki

    2004-01-01

    The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model

  2. Evaluating Judicial Performance and Addressing Gender Bias

    Directory of Open Access Journals (Sweden)

    Angela Melville

    2014-12-01

    Full Text Available Elek and Rottman argue that judicial evaluation is often biased against women and minority judges. The need to address bias is important, however often the desire for diversity seems so self-evident as to belie deeper analysis. This paper examines the two main rationales for gender equality on the bench. First, female judges are often considered necessary in order to bring a gendered perspective to judging, however it is argued that this rationale is flawed. Second, an alternative rationale based on equality and legitimacy is offered which avoids gender essentialism. While debates typically focus on these two rationales, a third rationale embraces both difference and equality/legitimacy. The presence of female judges has an important symbolic value which destabilises existing fraternal legal norms. Finally, increasing the number of female judges may not necessarily change judging, and this paper also analyses how the transformative potential offered by judicial diversity can work in practice. Elek y Rottman defienden que la evaluación judicial suele estar sesgada en contra de las mujeres y los jueces pertenecientes a minorías. La necesidad de abordar el sesgo es importante, sin embargo a menudo el deseo de diversidad parece tan evidente como para contradecir un análisis más profundo. Este artículo examina los dos motivos principales para la igualdad de género en el banquillo. En primer lugar, las mujeres jueces a menudo se consideran necesarias para aportar una perspectiva de género al hecho de juzgar, sin embargo, se defiende que este razonamiento es erróneo. En segundo lugar, se ofrece una alternativa lógica basada en la igualdad y la legitimidad que evita el esencialismo de género. Mientras que los debates suelen centrarse en estas dos razones, una tercera justificación abarca tanto la diferencia como la igualdad/legitimidad. La presencia de mujeres en la judicatura tiene un importante valor simbólico que desestabiliza las normas

  3. Performances evaluation of different open source

    Directory of Open Access Journals (Sweden)

    Arun Patel

    2016-06-01

    Full Text Available In Open sources DEMs such as SRTM, ASTER and Cartosat-1, various factors affecting the accuracy of satellite based DEM such as errors during data collection, systematic errors and unknown errors that are geographically dependent on terrain conditions cannot be avoided. For these reasons it is very necessary to check and compare the performances and validation of the above mentioned different satellite based DEMs. Accuracy assessment of these DEM has been done using DGPS points. For these points proper interpolation of the surface was developed using different interpolation techniques. For the generation of the surface the first step was converting the satellite based DEMs height into linear interpolation contour maps of 1 m interval. Then came selecting random sample points on the contour line and generating the interpolated surface using different interpolation techniques such as IDW, GPI, RBF, OK and UK, LPI, TR and BI, which are commonly used in geomorphology research. This interpolated surface helps in proper representation of the terrain and was checked under different terrain surfaces. For validation of DGPS points the height was taken for ground control points and standard statistical tests such as ME and RMSE were applied. From above investigation, it is reveals that above mention DEMs which are used for study. Cartosat-1 (30 m data product is better than SRTM (90 m and ASTER (30 m because it had produced low RMSE of 3.49 m without applying the interpolation method. Investigation also reveals after applying the interpolation techniques on this data error can be reduced. In the case of Cartosat-1 and SRTM, low RMSE and ME were produced by the BI method, where Cartosat-1 DEM had an RMSE of 3.36 m with ME of −2.74 m, respectively. But in this case, RMSE and ME of SRTM is 2.73 m and −0.36 m, respectively. BI is designed for image processing and can be used for imagery were a maximum height variation in satellite DEM and terrain

  4. Performance evaluation methods and instrumentation for mine ventilation fans

    Institute of Scientific and Technical Information of China (English)

    LI Man; WANG Xue-rong

    2009-01-01

    Ventilation fans are one of the most important pieces of equipment in coal mines. Their performance plays an important role in the safety of staff and production. Given the actual requirements of coal mine production, we instituted a research project on the measurement methods of key performance parameters such as wind pressure, amount of ventilation and power. At the end a virtual instrument for mine ventilation fans performance evaluation was developed using a USB interface. The practical perform-ance and analytical results of our experiments show that it is feasible, reliable and effective to use the proposed instrumentation for mine ventilation performance evaluation.

  5. Evaluation of Force Transfer Around Openings - Experimental and Analytical Studies

    Science.gov (United States)

    Borjen Yeh; Tom Skaggs; Frank Lam; Minghao Li; Douglas Rammer; James Wacker

    2011-01-01

    Wood structural panel (WSP) sheathed shear walls and diaphragms are the primary lateral-load-resistingelements in wood-frame construction. The historical performance of light-frame structures in North America is very good due, in part, to model building codes that are designed to safeguard life safety. These model building codes have spawned continual improvement and...

  6. Evaluation of cyclone geometry and its influence on performance parameters by computational fluid dynamics (CFD

    Directory of Open Access Journals (Sweden)

    W. P. Martignoni

    2007-03-01

    Full Text Available Cyclone models have been used without relevant modifications for more than a century. Most of the attention has been focused on finding new methods to improve performance parameters. Recently, some studies were conducted to improve equipment performance by evaluating geometric effects on projects. In this work, the effect of cyclone geometry was studied through the creation of a symmetrical inlet and a volute scroll outlet section in an experimental cyclone and comparison to an ordinary single tangential inlet. The study was performed for gas-solid flow, based on an experimental study available in the literature, where a conventional cyclone model was used. Numerical experiments were performed by using CFX 5.7.1. The axial and tangential velocity components were evaluated using RSM and LES turbulence models. Results showed that these new designs can improve the cyclone performance parameters significantly and very interesting details were found on cyclone fluid dynamics properties using RSM and LES.

  7. Parametric Evaluation of Racking Performance of Platform Timber Framed Walls

    OpenAIRE

    Dhonju, R..; D’Amico, B..; Kermani, A..; Porteous, J..; Zhang, B..

    2017-01-01

    This paper provides a quantitative assessment of the racking performance of partially anchored timber framed walls, based on experimental tests. A total of 17 timber framed wall specimens, constructed from a combination of materials under different load configurations, were tested. The experimental study was designed toexamine the influence of a range of geometrical parameters, such as fastener size and spacings, wall length, arrangement of studs and horizontal members, as well as the effect ...

  8. Experimental Evaluation of Wireless Communication Channels under Radiation Environment

    International Nuclear Information System (INIS)

    Wang, Quan; Bari, Ataul; Deng, Changjian; Li, Liquan

    2014-01-01

    Deployment of wireless systems in nuclear power plants has attracted a lot of attention recently. However, before wireless systems can be installed in a nuclear power plant, it is necessary to evaluate the effect of radiation environment on electromagnetic wave which is the communication media for all radio wave based wireless systems. This is particular important if the wireless systems are expected to work in a harsh and radioactive environment following a severe accident. This paper presents some results of an experiment for evaluating the effect of radiation on electromagnetic wave. The experiments involve placing transmitter antenna and receiver antenna in a hot cell with variable strength of radiation to study the attenuation effects of the radioactive media. The results indicate that radiation does not effect on the electromagnetic wave propagation. This fact should be considered during the design and deployment wireless systems in a potentially radioactive environment

  9. EXPERIMENTAL PERFORMANCE OF R134a AND R152a USING MICROCHANNEL CONDENSER

    OpenAIRE

    Bhatkar, V. W.

    2018-01-01

    An experimental performance study on vapour compression refrigeration system with R134a and drop in substitute R152a with aluminium microchannel condenser was carried out for condensation temperature of 48°C while evaporation temperature varied from -10 to 15°C. Refrigerant charge of R152a was reduced by 40% over R134a with the microchannel condenser. Performance parameters like work input to the compressor, coefficient of performance, refrigerating capacity, condenser capacity and the produc...

  10. Creating 3D gelatin phantoms for experimental evaluation in biomedicine

    Directory of Open Access Journals (Sweden)

    Stein Nils

    2015-09-01

    Full Text Available We describe and evaluate a setup to create gelatin phantoms by robotic 3D printing. Key aspects are the large workspace, reproducibility and resolution of the created phantoms. Given its soft tissue nature, the gelatin is kept fluid during inside the system and we present parameters for additive printing of homogeneous, solid objects. The results indicate that 3D printing of gelatin can be an alternative for quickly creating larger soft tissue phantoms without the need for casting a mold.

  11. Performance Evaluation of Bluetooth Low Energy: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Jacopo Tosi

    2017-12-01

    Full Text Available Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.. In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.

  12. Use of field experimental studies to evaluate emergency response models

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Lange, R.; Rodriguez, D.J.; Nasstrom, J.S.

    1985-01-01

    The three-dimensional diagnostic wind field model (MATHEW) and the particle-in-cell atmospheric transport and diffusion model (ADPIC) are used by the Atmospheric Release Advisory Capability to estimate the environmental consequences of accidental releases of radioactivity into the atmosphere. These models have undergone extensive evaluations against field experiments conducted in a variety of environmental settings ranging from relatively flat to very complex terrain areas. Simulations of tracer experiments conducted in a complex mountain valley setting revealed that 35 to 50% of the comparisons between calculated and measured tracer concentrations were within a factor of 5. This may be compared with a factor of 2 for 50% of the comparisons for relatively flat terrain. This degradation of results in complex terrain is due to a variety of factors such as the limited representativeness of measurements in complex terrain, the limited spatial resolution afforded by the models, and the turbulence parameterization based on sigma/sub theta/ measurements to evaluate the eddy diffusivities. Measurements of sigma/sub theta/ in complex terrain exceed those measured over flat terrain by a factor of 2 to 3 leading to eddy diffusivities that are unrealistically high. The results of model evaluations are very sensitive to the quality and the representativeness of the meteorological data. This is particularly true for measurements near the source. The capability of the models to simulate the dispersion of an instantaneously produced cloud of particulates was illustrated to be generally within a factor of 2 over flat terrain. 19 refs., 16 figs

  13. Performance evaluation study of IHX-IV seal assembly

    Energy Technology Data Exchange (ETDEWEB)

    Padmakumar, G.; Venkatramanan, J.; Balasubramanian, V.; Prakash, V.; Vaidyanathan, G. [Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Konnur, M.S.; Ram Mohan, S.; Suresh, M.; Manikandan, S.; Rajesh, V. [Fluid Control Research Institute, Palakkad - 678 623 (India)

    2005-07-01

    Full text of publication follows: The construction of the 500 MWe Prototype Fast Breeder Reactor (PFBR) has commenced at IGCAR, Kalpakkam. PFBR has four intermediate Heat Exchangers (IHX) and two primary Sodium Pumps. The secondary circuits consist of two loops with each loop having one secondary pump, two intermediate heat exchangers, one surge tank and four steam generators. Primary circuit has both hot and cold sodium and is separated into hot and cold pools by Inner Vessel(IV). IHX forms the interface between the primary circuit and secondary circuit of PFBR. The IHX and pumps are supported from at the top in the roof slab and penetrate through the conical portion of inner vessel. Proper sealing arrangements are necessary to prevent leakage of hot sodium into the cold pool through the penetration. The Mechanical Seal is employed to minimize the leakage through the penetration. This seal arrangement can facilitate Differential radial and thermal expansion between IHX and IV stand pipe at the region of penetration Relative tilting between the axis of IHX and IV stand pipe Smooth installation during commissioning and easy removal during maintenance Minimizes the forces transmitted to IV The hydraulic simulation study, of the IHX - IV mechanical seal assembly was undertaken at the Fluid Control Research Institute, Palghat. The seal has two leakage paths viz. Axial and radial. The leakage depends on the contact pressure on the sealing surface and the head causing the leakage. High leakage flow may lead to damage of inner vessel and may affect the thermal efficiency of the IHX. CFD analysis of the geometry was done in detail. This was done for prototype and the model condition. The optimized design obtained using CFD was employed for experimental evaluation. In the experimental set up, the leakage characteristics was studied for varying axial and radial clearance that prevails during the various stages of operation of the seal assembly in the reactor. A 1/2 scaled

  14. Who Should Evaluate Teachers' Performance at Schools?

    Science.gov (United States)

    Tabancali, Erkan

    2017-01-01

    Correct determination of whether or not the objectives are achieved or of the level of achievement of the objectives is vital in educational organizations. In this context, one of the indicators of how teachers serve the organizational objectives is performance evaluation. In Turkish Educational System, the evaluation of the performance of…

  15. 48 CFR 36.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Evaluation of contractor performance. 36.201 Section 36.201 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Contracting for Construction 36.201 Evaluation of contractor performance. See 42.1502(e) for the requirements...

  16. State of the art of durability-performance evaluation of hardened cement based on phase compositions

    International Nuclear Information System (INIS)

    Kurashige, Isao; Imoto, Harutake; Yamamoto, Takeshi; Hironaga, Michihiko

    2006-01-01

    Upgrading durability-performance evaluation technique for concrete is urgently demanded in connection to its application to radio-active waste repository which needs ultra long-term durability. Common concrete structures also require an advanced method for minimizing the life-cycle cost. The purpose of this research is to investigate current problems and future tasks on durability-performance evaluation of hardened cement from the view point of phase composition. Although the phase composition of hardened cement has not fully been reflected to durability-performance evaluation, it influences concrete durability as well as its pore structure. This report reviews state of the art of the factors affecting phase composition, analytical and experimental evaluation techniques for phase composition, and durability-performance evaluation methods of hardened cement based on phase composition. (author)

  17. Experimental evaluation of 8 kW grid-connected photovoltaic system in Egypt

    Directory of Open Access Journals (Sweden)

    A. Elkholy

    2016-09-01

    Full Text Available An experimental observation study of 8 kW grid-connected photovoltaic (PV system that is installed at Electronics Research Institute (ERI, Giza, Egypt (Latitude 30.04°N, Longitude 31.21°E, is presented. This study includes the quality of the electrical power generated and injected into the network. The considered system consists of 28 × 295 Wp multicrystalline PV modules, StecaGrid three-phase 8 kW grid-connected inverter and a Solar-Log 300 PM+ for data acquisition and remote monitoring. The power quality parameters at the inverter output side have been measured using CA8335 power quality analyzer. The system has been installed in August 2014 and generated 5.7 MWh till February 2015. The produced electricity by the system is injected directly into the grid without storage device. The purpose of this paper is to present and evaluate the measurements of the power quality parameters obtained from the PV site. Also, this paper presents a comprehensive evaluation of the performance of the system over a period of one week. The observation and analyses exploitation of the collected data can help to evaluate the performance of the PV system connected to the network.

  18. Research on Performance Evaluation by IDSS Based on AHP

    Directory of Open Access Journals (Sweden)

    Tang Xuelian

    2013-03-01

    Full Text Available Talent resource is the primary resource. There are two sides as the starting point and foothold in this paper. One is how to evaluate the performance of science and technology talents flow by IDSS (Intelligence Decision Supporting System. Another is how to guide the innovation work of science and technology according to the evaluation results. The evaluation index on performance system has hierarchical structure. So AHP (Analytic Hierarchy Process is applied to evaluate the performance. Evaluation model is established and illustrated by the cases in this paper. It can be seen that the flow of performance is influenced by the growth rate of important scientific and technological achievements. Furthermore, some constructive suggestions are given based on the results of evaluation.

  19. A model of R-D performance evaluation for Rate-Distortion-Complexity evaluation of H.264 video coding

    DEFF Research Database (Denmark)

    Wu, Mo; Forchhammer, Søren

    2007-01-01

    This paper considers a method for evaluation of Rate-Distortion-Complexity (R-D-C) performance of video coding. A statistical model of the transformed coefficients is used to estimate the Rate-Distortion (R-D) performance. A model frame work for rate, distortion and slope of the R-D curve for inter...... and intra frame is presented. Assumptions are given for analyzing an R-D model for fast R-D-C evaluation. The theoretical expressions are combined with H.264 video coding, and confirmed by experimental results. The complexity frame work is applied to the integer motion estimation....

  20. An Experimental Evaluation of Mechanical Properties of Hybrid Reinforcements

    Science.gov (United States)

    Sai Kumar, A.; Ganesan, G.; Karthikeyan, K.

    2017-07-01

    This paper presents the mechanical properties of unidirectional hybrid reinforcements formed from continuous fibres impregnated with a fibre binding material which are used for reinforcing the concrete. Recently FRP (Fibre Reinforced Polymer) manufacturers and suppliers have been increased all over the world because of the superior performance of FRP products in the construction industry. Its non-corrosive nature has turned the attention of many researchers to make several studies on different type of FRP products. Through a vast research, several standards also have been formulated. In this regard a new combination of FRP materials is tried in this paper and its properties have been derived. Carbon fibre and glass fibres fuse in this study to form a new hybrid rebar. The design properties such as tensile strength, tensile modulus, and compressive strength have been studied as per ASTM standards and it has been identified that the Hybrid rebar show a superior performance in comparison with GFRP (Glass FRP) and Steel rebars. This extraordinary performance of hybrid composite material increases the extensive engineering applications such as transport industry, aeronautics, naval, automotive industries.