WorldWideScience

Sample records for experimental glaucoma filtration

  1. Macular thickness after glaucoma filtration surgery.

    Science.gov (United States)

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  2. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    OpenAIRE

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-01-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medicat...

  3. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma.

    Science.gov (United States)

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-05-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications) was achieved in eight cases (66.7%) and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications) in two cases (16.7%) at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37). ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma's, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  4. The impact of available anti-glaucoma therapy on the volume and age profile of patients undergoing glaucoma filtration surgery.

    LENUS (Irish Health Repository)

    Keane, P A

    2012-02-01

    PURPOSE: To investigate whether new classes of glaucoma medication have influenced glaucoma filtration surgery over a 20-year period in the southeast region of Ireland. METHODS: All patients undergoing glaucoma filtration surgery between January 1986 and December 2005 in Waterford Regional Hospital were identified. The following data were recorded for each patient: age; sex; and type of filtration procedure. RESULTS: Over the 20-year study period two consultant ophthalmic surgeons performed a total of 760 glaucoma filtration procedures on patients aged over 20 years. The annual average number of glaucoma surgeries declined steadily, defined by availability of different topical anti-glaucoma medications, from an average of 23.75 surgeries per surgeon per year in the subperiod 1986-1995, to 21 in 1996, 20 in 1997, and 12.69 surgeries per surgeon per year in 1998-2005, these differences being statistically significant (general linear model, P<0.001). The age profile of patients did not change significantly over the course of the study period. CONCLUSIONS: The volume of patients requiring glaucoma filtration surgery under the care of two consultant ophthalmic surgeons decreased over the 20-year study period, an era in which three classes of anti-glaucoma medications were made available. However, an increase in the age profile of patients undergoing glaucoma filtration surgery during the same period was not observed. Further study is required to resolve whether introduction of the new topical anti-glaucoma medications has led to a real reduction in the demand for glaucoma filtration surgery, or has just led to the deferral of such a demand.

  5. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    Directory of Open Access Journals (Sweden)

    Dewang Angmo

    2015-01-01

    Full Text Available ExPress glaucoma filtration device (GFD has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications was achieved in eight cases (66.7% and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications in two cases (16.7% at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37. ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma′s, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  6. Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients

    Directory of Open Access Journals (Sweden)

    Salim S

    2012-06-01

    Full Text Available Sarwat Salim, Haiming Du, Sumalee Boonyaleephan, Jim WanUniversity of Tennessee Health Science Center, Memphis, TN, USAPurpose: To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients.Design: Retrospective comparative case series.Methods: This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for uncontrolled glaucoma. All eyes received intraoperative mitomycin C. The primary outcome measures were intraocular pressure (IOP, number of postoperative glaucoma medications, and surgical success. Surgical success was defined as IOP between 5 and 18 mm Hg, with or without glaucoma medications, without further glaucoma surgery, or loss of light perception vision. Results: Average follow-up was 31.9 ± 9.8 (range, 14.6–47 months for African Americans and 30.7 ± 8.6 (range, 14.3–47 months for whites. At 33 months, surgical success was 80.0% in the African American group and 83.3% in the white group (P = 1.00. Reasons for surgical failure included increased IOP (3 eyes, 3.8%, persistent hypotony with maculopathy (1 eye, 1.3%, and further surgery (4 eyes, 5.06%. Compared with preoperative values, the mean postoperative IOP and number of glaucoma medications were significantly reduced in both groups, and no statistical difference was observed between the two groups at 33 months. Postoperative complications were similar in the two groups.Conclusions: Similar surgical outcomes were observed in African American and white glaucoma patients after implantation of the Ex-PRESS glaucoma filtration device. This latest modification of glaucoma filtration surgery may be a better surgical option for African Americans given its potential advantages of no tissue removal, predictable outcomes related to consistent lumen size and controlled flow, fewer

  7. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma

    NARCIS (Netherlands)

    de Jong, Leo; Lafuma, Antoine; Aguadé, Anne-Sophie; Berdeaux, Gilles

    2011-01-01

    This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS

  8. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An ... group of conditions that can result in irreversible blindness. This vision loss can be reduced if glaucoma ...

  9. [Sinusotrabeculectomy with regulated filtration in the treatment of secondary glaucoma].

    Science.gov (United States)

    Barashkov, V I; Dushin, N V; Beliaev, V S; Kravchinina, V V; Gonchar, P A; Frolov, M A; Semin, S B

    1999-01-01

    A new method for surgical treatment of secondary glaucoma (neovascular, postuveal, traumatic, and aphakic) is described. The aims of the new method are as follows: regulation of ophthalmic tone in the postoperative period, pain relief, organ preservation, stabilization of the process, and creation of reliable routes of intraocular fluid discharge with formation of a stable diffuse functional pad. Seven patients (8 eyes) aged 13-70 years were operated on and followed up for up to 6 months. Preliminary results are presented. Positive shifts were observed in all cases.

  10. The Effect of Dry Eye Disease on Scar Formation in Rabbit Glaucoma Filtration Surgery

    Directory of Open Access Journals (Sweden)

    Hong Ji

    2017-05-01

    Full Text Available The success rate of glaucoma filtration surgery is closely related to conjunctival inflammation, and the main mechanism of dry eye disease (DED is inflammation. The aim of this study was to evaluate the effect of DED on bleb scar formation after rabbit glaucoma filtration surgery. Sixteen New Zealand white rabbits were randomly divided into control and DED groups. A DED model was induced by twice-daily topical administration of 0.1% benzalkonium chloride (BAC drops for three weeks. Ocular examinations were performed to verify the DED model. Surgical effects were assessed, and histologic assessments were performed on the 28th postoperative day. Higher fluorescein staining scores, lower basal tear secretion levels and goblet cell counts, and increased interleukin 1β (IL-1β levels were observed in the DED group. The DED eyes displayed significantly higher intraocular pressure (IOP% on the 14th postoperative day; a smaller bleb area on days 14, 21 and 28; and a shorter bleb survival time. Moreover, proliferating cell nuclear antigen (PCNA and alpha-smooth muscle actin (α-SMA levels were significantly increased in the DED group. These results demonstrate that DED promotes filtering bleb scar formation and shortens bleb survival time; these effects may be mediated via IL-1β.

  11. Anti-glaucoma potential of Heliotropium indicum Linn in experimentally-induced glaucoma

    OpenAIRE

    Kyei, Samuel; Koffuor, George Asumeng; Ramkissoon, Paul; Owusu-Afriyie, Osei

    2015-01-01

    Background Heliotropium indicum is used as a traditional remedy for hypertension in Ghana. The aim of the study was to evaluate the anti-glaucoma potential of an aqueous whole plant extract of H. indicum to manage experimentally-induced glaucoma. Methods The percentage change in intraocular pressure (IOP), after inducing acute glaucoma (15 mLkg?1 of 5?% dextrose, i.v.), in New Zealand White rabbits pretreated with Heliotropium indicum aqueous extract (HIE) (30?300 mgkg?1), acetazolamide (5 mg...

  12. Feasibility analysis of Triptolide's role in treating filtering bleb fibrosis after the filtration surgery of glaucoma

    Directory of Open Access Journals (Sweden)

    Ting Chen

    2014-06-01

    Full Text Available At present, filtration surgery remains an important treatment of glaucoma, and filtering bleb fibrosis is the main cause for treatment failure. Filtering bleb fibrosis is a common fiber hyperplastic disease, and it relates to the activation and proliferation of fibroblasts and the excessive production of extracellular matrix(ECMsuch as collagen protein. The most frequently-used drugs for filtering bleb fibrosis in clinic are 5-fluoro-2,4(1h, 3hpyrimidinedione(5-Fuand mitomycin(MMC. Although they are effective in some degree, they also have some serious side effects which restrict their clinical use. Triptolide(TPLis a major active component of the medicinal plant, tripterygium wilfordii hook.f.(TWHF. TPL has multiple pharmacological activities including immunosuppressive, anti-inflammatory, anti-cancer and anti-fertility activity. Reviewing related literatures published in recent ten years, we confirmed that TPL seemed to possess a pharmacological activity in treating filtering bleb fibrosis. Since it has three major functions: 1. inhibit the activation and proliferation of fibroblasts and the excessive production of collagen protein; 2. alleviate the inflammatory reaction after surgical wound to suppress fibrous scar formation; 3.TPL has a protective effect on retinal ganglion cells(RGCs. We further find that TPL's anti-fibrosis activity mainly results from that it inhibits TGF-β/Smad,NF-κB and PI3K/AKT signal transduction pathway. This comprehensive analysis about the feasibility of Triptolide's role in treating filtering bleb fibrosis after the filtration surgery of glaucoma can help us develop new drugs for filtering bleb fibrosis and exploit TPL's clinical value on some level.

  13. Glaucoma

    Science.gov (United States)

    ... glaucoma Images Eye Slit-lamp exam Visual field test Glaucoma References Anderson DR. The optic nerve in glaucoma. In: Tasman W, Jaeger EA, eds. Duane's Ophthalmology 2013 . Philadelphia, PA: Lippincott Williams & Wilkins; 2013:vol 3, chap 48. Giaconi JA, ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma NEI ...

  15. Scleral fibroblast response to experimental glaucoma in mice

    Science.gov (United States)

    Tezel, Gülgün; Cone-Kimball, Elizabeth; Steinhart, Matthew R.; Jefferys, Joan; Pease, Mary E.; Quigley, Harry A.

    2016-01-01

    Purpose To study the detailed cellular and molecular changes in the mouse sclera subjected to experimental glaucoma. Methods Three strains of mice underwent experimental bead-injection glaucoma and were euthanized at 3 days and 1, 3, and 6 weeks. Scleral protein expression was analyzed with liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) using 16O/18O labeling for quantification in 1- and 6-week tissues. Sclera protein samples were also analyzed with immunoblotting with specific antibodies to selected proteins. The proportion of proliferating scleral fibroblasts was quantified with Ki67 and 4’,6-diamidino-2-phenylindole (DAPI) labeling, and selected proteins were studied with immunohistochemistry. Results Proteomic analysis showed increases in molecules involved in integrin-linked kinase signaling and actin cytoskeleton signaling pathways at 1 and 6 weeks after experimental glaucoma. The peripapillary scleral region had more fibroblasts than equatorial sclera (p=0.001, n=217, multivariable regression models). There was a sixfold increase in proliferating fibroblasts in the experimental glaucoma sclera at 1 week and a threefold rise at 3 and 6 weeks (p=0.0005, univariate regression). Immunoblots confirmed increases for myosin, spectrin, and actinin at 1 week after glaucoma. Thrombospondin-1 (TSP-1), HINT1, vimentin, actinin, and α-smooth muscle actin were increased according to immunohistochemistry. Conclusions Scleral fibroblasts in experimental mouse glaucoma show increases in actin cytoskeleton and integrin-related signaling, increases in cell division, and features compatible with myofibroblast transition. PMID:26900327

  16. Management of hypotony and flat anterior chamber associated with glaucoma filtration surgery

    Directory of Open Access Journals (Sweden)

    Yavuz Tunç

    2015-10-01

    Full Text Available AIM:To determine the effectiveness of pharmacological and interventional treatment of hypotony and flat anterior chamber (FAC resulting from glaucoma filtration surgery.METHODS:We retrospectively examined the medical records of fifty-two trabeculectomy patients (52 eyes who developed postoperative hypotony and FAC. The management and associated complications of hypotony, changing intraocular pressure (IOP and best corrected visual acuity (BCVA were evaluated.RESULT:Of the 52 patients with hypotony, 29 (56% had a grade 1 FAC, 21 (40% had a grade 2 FAC, and only 2 had a grade 3 FAC. There was no significant difference between the mean preoperative IOP and the mean IOP at three and six months after surgery. Thirteen eyes (25% required antiglaucomatous medication three months after surgery. The mean BCVA at 6mo after surgery was significantly reduced as compared with the mean preoperative BCVA.CONCLUSION:Hypotonia and FAC following trabeculectomy are associated with troublesome complications that require pharmacological and/or surgical treatment. Thus, close follow-up is essential for affected patients.

  17. Glaucoma

    Medline Plus

    Full Text Available ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ... Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and Aging ... Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded ...

  20. Glaucoma

    Medline Plus

    Full Text Available ... YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma ... *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the ...

  1. Glaucoma

    Science.gov (United States)

    Glaucoma is a group of diseases that can damage the eye's optic nerve. It is a leading ... no symptoms at first. Without treatment, people with glaucoma will slowly lose their peripheral, or side vision. ...

  2. Anti-glaucoma potential of Heliotropium indicum Linn in experimentally-induced glaucoma.

    Science.gov (United States)

    Kyei, Samuel; Koffuor, George Asumeng; Ramkissoon, Paul; Owusu-Afriyie, Osei

    2015-01-01

    Heliotropium indicum is used as a traditional remedy for hypertension in Ghana. The aim of the study was to evaluate the anti-glaucoma potential of an aqueous whole plant extract of H. indicum to manage experimentally-induced glaucoma. The percentage change in intraocular pressure (IOP), after inducing acute glaucoma (15 mLkg(-1) of 5 % dextrose, i.v.), in New Zealand White rabbits pretreated with Heliotropium indicum aqueous extract (HIE) (30-300 mgkg(-1)), acetazolamide (5 mgkg(-1)), and normal saline (10 mLkg(-1)) per os were measured. IOPs were also monitored in chronic glaucoma in rabbits (induced by 1 % prednisolone acetate drops, 12 hourly for 21 days) after treatments with the same doses of HIE, acetazolamide, and normal saline for 2 weeks. The anti-oxidant property of the extract was assessed by assaying for glutathione levels in the aqueous humour. Glutamate concentration in the vitreous humour was also determined using ELISA technique. Histopathological assessment of the ciliary bodies was made. The extract significantly reduced intraocular pressure (p ≤ 0.05-0.001) in acute and chronic glaucoma, preserved glutathione levels and glutamate concentration (p ≤ 0.01-0.001). Histological assessment of the ciliary body showed a decrease in inflammatory infiltration in the extract and acetazolamide-treated group compared with the normal saline-treated group. The aqueous whole plant extract of Heliotropium indicum has ocular hypotensive, anti-oxidant and possible neuro-protective effects, which therefore underscore its plausible utility as an anti-glaucoma drug with further investigation.

  3. Non-penetrating filtration surgery versus trabeculectomy for open-angle glaucoma.

    Science.gov (United States)

    Eldaly, Mohamed A; Bunce, Catey; Elsheikha, Ola Z; Wormald, Richard

    2014-02-15

    -penetrating glaucoma surgery (of which 101 eyes had deep sclerectomy and 50 eyes had viscocanalostomy). The confidence interval (CI) for the odds ratio (OR) of success (defined as achieving target eye pressure without eye drops) does not exclude a beneficial effect of either deep sclerectomy or trabeculectomy (OR 0.98, 95% CI 0.51 to 1.88). The odds of success in viscocanalostomy participants was lower than in trabeculectomy participants (OR 0.33, 95% CI 0.13 to 0.81). We did not combine the different types of non-penetrating surgery because there was evidence of a subgroup difference when examining total success. The odds ratio for achieving target eye pressure with or without eye drops was imprecise and was compatible with a beneficial effect of either trabeculectomy or non-penetrating filtration surgery (NPFS) (OR 0.79, 95% CI 0.35 to 1.79). Operative adjuvants were used in both treatment groups; more commonly in the NPFS group compared to the trabeculectomy group but no clear effect of their use could be determined. Although the studies were too small to provide definitive evidence regarding the relative safety of the surgical procedures we noted that there were relatively fewer complications with non-filtering surgery compared to trabeculectomy (17% and 65% respectively). Cataract was more commonly reported in the trabeculectomy studies. None of the five trials used quality of life measure questionnaires. The methodological quality of the studies was not good. Most studies were at high risk of bias in at least one domain and for many, there was lack of certainty due to incomplete reporting. Adequate sequence generation was noted only in one study. Similarly, only two studies avoided detection bias. We detected incomplete outcome data in three of the included studies. This review provides some limited evidence that control of IOP is better with trabeculectomy than viscocanalostomy. For deep sclerectomy, we cannot draw any useful conclusions. This may reflect surgical difficulties

  4. Glaucoma

    Medline Plus

    Full Text Available ... Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... YouTube Videos » NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: ...

  6. A comparative study of the safety and efficacy effect of 5-fluorouracil or mitomycin C mounted biological delivery membranes in a rabbit model of glaucoma filtration surgery.

    Science.gov (United States)

    Wu, Zhihong; Li, Shuning; Wang, Ningli; Liu, Wanshun; Liu, Wen

    2013-01-01

    To investigate the potential usage of biological delivery membranes containing mitomycin C (MMC) or 5-fluorouracil (5-FU) in the construction of glaucoma-filtering blebs, and to evaluate their safety and efficacy. Chitosan was selected as the biological membrane carrier to prepare sustained-released membranes. Twelve micrograms of 5-FU or MMC was covalently conjugated onto the membranes by solvent volatilization. Rabbits underwent glaucoma filtration surgery and were randomly allocated into one of the four treatment regimens: glaucoma filtration operation with no implantation of chitosan membrane group (as control), drug-free chitosan membrane implantation group (blank/placebo group), membrane containing 5-FU treatment group (5-FU group), and membrane containing MMC treatment group (MMC group). Each group consisted of 12 rabbits. Intraocular pressure (IOP) was measured and evaluated over a 28-day period follow-up preoperatively, then after surgery on days 1, 3, 5, 7, 14, 21, and 28 by Tono-Pen. The aqueous humor was analyzed in each experimental and control groups at days 4, 6, 8, 10, 12, 14, 16, and 20 after operation. Bleb survival and anterior segment were examined with a slit lamp microscope and photographed simultaneously. Two rabbits from each group were killed on day 28 and eight eye samples obtained for histopathological study. Corneas and lenses were examined by transmission and scanning electron microscopy. Both 5-FU and MMC significantly prolonged bleb survival compared with control groups. The filtering bleb's survival period was significantly more prolonged in the MMC and 5-FU groups (maintained 14 days) than the other two groups (maintained 7 days). Significantly lower IOP was observed within the control, blank, and 5-FU groups after surgery on day 14 compared with that before operation, with F-values of 6.567, 11.426, and 13.467, respectively (P < 0.01). The most significant lower IOP was recorded in the MMC group on day 28 postoperation (F-value 26

  7. Glaucoma

    Medline Plus

    Full Text Available ... Education Programs National Eye Health Education Program (NEHEP) Diabetic Eye Disease Education Program Glaucoma Education Program Low ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino ... To search for current job openings visit HHS USAJobs Home » NEI YouTube ...

  13. Treating malfunction filtering bleb with repeated needling combined with adjunctive 5-FU after glaucoma filtration surgery

    Directory of Open Access Journals (Sweden)

    Yi Liu

    2013-07-01

    Full Text Available AIM: To evaluate the therapeutic efficacy of a repeated bleb needling technique combined with subconjunctival injection of 5-FU in eyes with previous glaucoma surgery that had malfunctional filtering blebs. METHODS: A retrospective review of 34 consecutive patients(34 eyesof repeated bleb needling combined with subconjunctival injection of 5-FU in eyes, which had malfunctional filtering blebs after previous glaucoma surgery in our hospital from March 2009 to February 2013 was performed. The intraocular pressures(IOP, shapes of filtering blebs and complications after surgery were analyzed. RESULTS: There was significant reduction of mean IOP from 35.51mmHg to 14.43mmHg(PCONCLUSION: Repeated needling with adjunctive 5-FU proved a highly effective, safe alternative to treat malfunctional filtering blebs after previous glaucoma surgery.

  14. The Non-Human Primate Experimental Glaucoma Model

    Science.gov (United States)

    Burgoyne, Claude F.

    2015-01-01

    The purpose of this report is to summarize the current strengths and weaknesses of the non-human primate (NHP) experimental glaucoma (EG) model through sections devoted to its history, methods, important findings, alternative optic neuropathy models and future directions. NHP EG has become well established for studying human glaucoma in part because the NHP optic nerve head (ONH) shares a close anatomic association with the human ONH and because it provides the only means of systematically studying the very earliest visual system responses to chronic IOP elevation, i.e. the conversion from ocular hypertension to glaucomatous damage. However, NHPs are impractical for studies that require large animal numbers, demonstrate spontaneous glaucoma only rarely, do not currently provide a model of the neuropathy at normal levels of IOP, and cannot easily be genetically manipulated, except through tissue-specific, viral vectors. The goal of this summary is to direct NHP EG and non-NHP EG investigators to the previous, current and future accomplishment of clinically relevant knowledge in this model. PMID:26070984

  15. Sphingosine-1-Phosphate (S1P)-Related Response of Human Conjunctival Fibroblasts After Filtration Surgery for Glaucoma.

    Science.gov (United States)

    Aoyama-Araki, Yuka; Honjo, Megumi; Uchida, Takatoshi; Yamagishi, Reiko; Kano, Kuniyuki; Aoki, Junken; Aihara, Makoto

    2017-04-01

    To investigate levels of sphingosine-1-phosphate (S1P) in aqueous fluid samples taken before and after filtration surgery and S1P-induced human conjunctival fibroblast (HCF) responses. Levels of S1P and its related sphingophospholipids in aqueous fluid obtained immediately before and after filtration surgery were determined by liquid chromatography-tandem mass spectrometry. HCFs were used for all in vitro experiments. The expression of five S1P receptor subtypes in HCFs was examined by quantitative real-time PCR. The effect of S1P and receptor-specific antagonists on HCF viability and cell migration was assessed by WST-1 assay and scratch migration assay, respectively. Differentiation to myofibroblasts and extracellular matrix production was evaluated by examining changes in F-actin, α-smooth muscle actin (αSMA), and collagen expression with immunocytochemistry, Western blotting, and collagen accumulation assay, respectively. No significant S1P levels in the aqueous fluid samples were detectable immediately before surgery, but postoperative levels of several lysophospholipids, including S1P, dehydro-S1P, and sphingosine, were significantly increased to bioactive concentrations in aqueous fluid in the blebs (P S1P receptor subtypes was detected in HCFs. Although S1P levels did not influence HCF proliferation, S1P enhanced cell migration, which could be inhibited by the S1P2 antagonist JTE 013. F-actin, αSMA, and collagen expression was significantly increased by S1P stimulation and was reduced by JTE 013. Bioactive S1P concentrations were present in the aqueous fluid at the end of filtration surgery. S1P activated HCFs via S1P2 receptors. These results revealed the potential of S1P2 antagonists in preventing scarring after glaucoma filtration surgery.

  16. Glaucoma

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence ... is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  20. Glaucoma

    Science.gov (United States)

    ... considerably, providing more precise visual assessment tests and biologic markers for the disease. NIH-sponsored research led to the development of prostaglandins, a new class of drugs that offers excellent IOP control with fewer side effects. The Early Manifest Glaucoma ...

  1. A comparative study of the safety and efficacy effect of 5-fluorouracil or mitomycin C mounted biological delivery membranes in a rabbit model of glaucoma filtration surgery

    Directory of Open Access Journals (Sweden)

    Wu ZH

    2013-03-01

    Full Text Available Zhihong Wu,1 Shuning Li,2 Ningli Wang,2 Wanshun Liu,3 Wen Liu3 1General Hospital of Armed Police Forces, Beijing, People’s Republic of China; 2Beijing Tongren Eye Center, Capital Medical University, Beijing, People’s Republic of China 3Ocean University of China, Qingdao, People’s Republic of China Purpose: To investigate the potential usage of biological delivery membranes containing mitomycin C (MMC or 5-fluorouracil (5-FU in the construction of glaucoma-filtering blebs, and to evaluate their safety and efficacy. Methods: Chitosan was selected as the biological membrane carrier to prepare sustained-released membranes. Twelve micrograms of 5-FU or MMC was covalently conjugated onto the membranes by solvent volatilization. Rabbits underwent glaucoma filtration surgery and were randomly allocated into one of the four treatment regimens: glaucoma filtration operation with no implantation of chitosan membrane group (as control, drug-free chitosan membrane implantation group (blank/placebo group, membrane containing 5-FU treatment group (5-FU group, and membrane containing MMC treatment group (MMC group. Each group consisted of 12 rabbits. Intraocular pressure (IOP was measured and evaluated over a 28-day period follow-up preoperatively, then after surgery on days 1, 3, 5, 7, 14, 21, and 28 by Tono-Pen. The aqueous humor was analyzed in each experimental and control groups at days 4, 6, 8, 10, 12, 14, 16, and 20 after operation. Bleb survival and anterior segment were examined with a slit lamp microscope and photographed simultaneously. Two rabbits from each group were killed on day 28 and eight eye samples obtained for histopathological study. Corneas and lenses were examined by transmission and scanning electron microscopy. Results: Both 5-FU and MMC significantly prolonged bleb survival compared with control groups. The filtering bleb’s survival period was significantly more prolonged in the MMC and 5-FU groups (maintained 14 days than the

  2. Neuroprotective effect of edaravone in experimental glaucoma model in rats: a immunofluorescence and biochemical analysis

    Directory of Open Access Journals (Sweden)

    Arzu Toruk Aksar

    2015-04-01

    Full Text Available AIM: To evaluate the neuroprotective activity of systemically administered edaravone in early and late stage of experimental glaucoma in rats. METHODS: In this study, 60 Wistar albino rats were used. Experimental glaucoma model was created by injecting hyaluronic acid to the anterior chamber once a week for 6wk in 46 of 60 subjects. Fourteen subjects without any medication were included as control group. Edaravone administered intraperitoneally 3 mg/kg/d to the 15 of 30 subjects starting at the onset of glaucoma induction and also administered intraperitoneally 3 mg/kg/d to the other 15 subjects starting at three weeks after the onset of glaucoma induction. The other 16 subjects who underwent glaucoma induction was administered any therapy. Retinal ganglion cells (RGCs have been marked with dextran tetramethylrhodamine (DTMR retrograde at the end of the sixth week and after 48h, subjects were sacrificed by the method of cardiac perfusion. Alive RGC density was assessed in the whole-mount retina. Whole-mount retinal tissues homogenized and nitric oxide (NO, malondialdehyde (MDA and total antioxidant capacity (TAC values were measured biochemically. RESULTS: RGCs counted with Image-Pro Plus program, in the treatment group were found to be statistically significantly protected, compared to the glaucoma group (Bonferroni, P<0.05. The neuroprotective activity of edaravone was found to be more influential by administration at the start of the glaucoma process. Statistically significant lower NO levels were determined in the glaucoma group comparing treatment groups (Bonferroni, P<0.05. MDA levels were found to be highest in untreated glaucoma group, TAC levels were found to be lower in the glaucoma induction groups than the control group (Bonferroni, P<0.05. CONCLUSION: Systemic administration of Edaravone in experimental glaucoma showed potent neuroprotective activity. The role of oxidative stress causing RGC damage in glaucoma was supported by this

  3. Clinical Efficacy and Safety of the EX-PRESS Filtration Device in Patients with Advanced Neovascular Glaucoma and Proliferative Diabetic Retinopathy

    Directory of Open Access Journals (Sweden)

    Rana Hanna

    2018-01-01

    Full Text Available Background: The prognosis of conventional filtration surgery in eyes with neovascular glaucoma (NVG is limited due to increased fibrovascular proliferation or bleeding. This study aims to evaluate the safety and efficacy of the EX-PRESS filtration device in the management of NVG associated with proliferative diabetic retinopathy (PDR. Methods: In this retrospective case series, we reviewed the medical records of patients diagnosed as having NVG associated with PDR who underwent EX-PRESS filtration surgery. The main outcome measures were: postoperative intraocular pressure (IOP, the percent of IOP drop, the number of glaucoma medications, visual acuity, and complications of surgery. Successful surgery was defined as an IOP <22 mm Hg and >5 mm Hg with or without additional glaucoma surgery, and no loss of light perception or less than a 2-line decrease on the Snellen chart of the best corrected visual acuity (BCVA. Results: Five patients (5 eyes were included in this study. The mean preoperative IOP was 33.4 ± 5.9 mm Hg compared to an IOP of 17.0 ± 3.0 mm Hg at the last follow-up (p = 0.003. The mean number of preoperative anti-glaucoma medications was 3.8 ± 0.4 compared to 2.2 ± 1.5 (p = 0.06 at the last follow-up visit. Final visual acuity improved or stabilized within 1 Snellen line in all 5 patients. Three patients had a “hypertensive phase” (defined as an IOP >21 mm Hg during the first 6 postoperative months which resolved within 2 months. Two patients developed a hyphema that resolved spontaneously. None of the patients experienced any serious complications. Conclusion: EX-PRESS filtration device has a good IOP-lowering effect and a low rate of complications in patients with advanced NVG associated with PDR. In addition, there was no loss of light perception or no line decrease of the BCVA.

  4. A review of the efficacy of mitomycin C in glaucoma filtration surgery

    Directory of Open Access Journals (Sweden)

    Al Habash A

    2015-10-01

    Full Text Available Ahmed Al Habash,1,2 Leyla Ali Aljasim,1 Ohoud Owaidhah,1 Deepak P Edward1,3 1King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia; 2Department of Ophthalmology, University of Dammam, Dammam, Saudi Arabia; 3Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA Abstract: The success of trabeculectomy, which is considered the gold standard in the surgical treatment of glaucoma, depends on the wound healing response. The introduction of antiproliferative agents such as mitomycin C (MMC has increased the success rates of trabeculectomy. However, complications due to these agents can be challenging to manage. Hence, it is important to determine the most efficacious dose and duration of exposure. Multiple studies suggest that many factors, including but not limited to MMC preparation, different concentrations, different exposure times, and method of application may affect success rate, and these factors were reviewed in this article. We concluded that lower concentrations of MMC that are prepared and applied in a standardized fashion, such as that using the Mitosol® kit (for 2–3 minutes during trabeculectomy, could potentially provide trabeculectomy success rates similar to that reported with off-label preparations, and that such a treatment regime could result in in lower complication rates than higher doses of MMC. Keywords: mitomycin C, Mitosol, filtering surgery, trabeculectomy, outcomes

  5. Experimental and Numerical Study of Ceramic Foam Filtration

    Science.gov (United States)

    Laé, E.; Duval, H.; Rivière, C.; Le Brun, P.; Guillot, J.-B.

    Ceramic foam filtration is widely used to enable removal of non metallic inclusions from liquid aluminium. Its performances have been largely studied in the literature and some discrepancies remain amongst the published results. Consequently, a research program was deployed to evaluate the performances of a range of ceramic foam filters used under various conditions and to understand the inclusions capture mechanisms.

  6. Experimental study of head loss and filtration for LOCA debris

    International Nuclear Information System (INIS)

    Rao, D.V.; Souto, F.J.

    1996-02-01

    A series of controlled experiments were conducted to obtain head loss and filtration characteristics of debris beds formed of NUKON trademark fibrous fragments, and obtain data to validate the semi-theoretical head loss model developed in NUREG/CR-6224. A thermally insulated closed-loop test set-up was used to conduct experiments using beds formed of fibers only and fibers intermixed with particulate debris. A total of three particulate mixes were used to simulate the particulate debris. The head loss data were obtained for theoretical fiber bed thicknesses of 0.125 inches to 4.0 inches; approach velocities of 0.15 to 1.5 ft/s; temperatures of 75 F and 125 F; and sludge-to-fiber nominal concentration ratios of 0 to 60. Concentration measurements obtained during the first flushing cycle were used to estimate the filtration efficiencies of the debris beds. For test conditions where the beds are fairly uniform, the head loss data were predictable within an acceptable accuracy range by the semi-theoretical model. The model was equally applicable for both pure fiber beds and the mixed beds. Typically the model over-predicted the head losses for very thin beds and for thin beds at high sludge-to-fiber mass ratios. This is attributable to the non-uniformity of such debris beds. In this range the correlation can be interpreted to provide upper bound estimates of head loss. This is pertinent for loss of coolant accidents in boiling water reactors

  7. Losartan Treatment Protects Retinal Ganglion Cells and Alters Scleral Remodeling in Experimental Glaucoma

    Science.gov (United States)

    Pitha, Ian F.; Nguyen, Cathy; Steinhart, Matthew R.; Nguyen, Thao D.; Pease, Mary Ellen; Oglesby, Ericka N.; Berlinicke, Cynthia A.; Mitchell, Katherine L.; Kim, Jessica; Jefferys, Joan J.

    2015-01-01

    Purpose To determine if oral losartan treatment decreases the retinal ganglion cell (RGC) death caused by experimental intraocular pressure (IOP) elevation in mice. Methods We produced IOP increase in CD1 mice and performed unilateral optic nerve crush. Mice received oral losartan, spironolactone, enalapril, or no drug to test effects of inhibiting angiotensin receptors. IOP was monitored by Tonolab, and blood pressure was monitored by tail cuff device. RGC loss was measured in masked axon counts and RGC bodies by β-tubulin labeling. Scleral changes that could modulate RGC injury were measured including axial length, scleral thickness, and retinal layer thicknesses, pressure-strain behavior in inflation testing, and study of angiotensin receptors and pathways by reverse transcription polymerase chain reaction, Western blot, and immunohistochemistry. Results Losartan treatment prevented significant RGC loss (median loss = 2.5%, p = 0.13), while median loss with water, spironolactone, and enalapril treatments were 26%, 28% and 43%; p glaucoma eyes (p = 0.007). Losartan inhibited effects of glaucoma, including reduction in extracellular signal-related kinase activity and modification of glaucoma-related changes in scleral thickness and creep under controlled IOP. Conclusions The neuroprotective effect of losartan in mouse glaucoma is associated with adaptive changes in the sclera expressed at the optic nerve head. PMID:26505191

  8. Experimental and clinical research on the inhibition of scarring formation after glaucoma surgery 90Sr radiation

    International Nuclear Information System (INIS)

    Wei Meien; Wang Guzhu; Li Shuqing

    1994-01-01

    Beta radiation of 90 Sr can inhibit the scarring formation so that the success rate of filtration surgery may be improved. After success in animal experiment, trabeculectomy was performed with small sclera flap on 31 eyes of 23 cases of patients with a high risk of scarring formation. Local 90 Sr radiation with a total dosage of 30.24 Gy were given by several times 3 days postoperatively, combined with local use of steroids. The patients were followed-up at 1 to 24 months, averaging 7 months. The intraocular pressure were successfully controlled in 90.3% of the patients. No lens impairment and other complications were observed. This procedure is an adoptive method in preventing scarring formation after glaucoma filtering surgery

  9. Losartan Treatment Protects Retinal Ganglion Cells and Alters Scleral Remodeling in Experimental Glaucoma.

    Directory of Open Access Journals (Sweden)

    Harry A Quigley

    Full Text Available To determine if oral losartan treatment decreases the retinal ganglion cell (RGC death caused by experimental intraocular pressure (IOP elevation in mice.We produced IOP increase in CD1 mice and performed unilateral optic nerve crush. Mice received oral losartan, spironolactone, enalapril, or no drug to test effects of inhibiting angiotensin receptors. IOP was monitored by Tonolab, and blood pressure was monitored by tail cuff device. RGC loss was measured in masked axon counts and RGC bodies by β-tubulin labeling. Scleral changes that could modulate RGC injury were measured including axial length, scleral thickness, and retinal layer thicknesses, pressure-strain behavior in inflation testing, and study of angiotensin receptors and pathways by reverse transcription polymerase chain reaction, Western blot, and immunohistochemistry.Losartan treatment prevented significant RGC loss (median loss = 2.5%, p = 0.13, while median loss with water, spironolactone, and enalapril treatments were 26%, 28% and 43%; p < 0.0001. The lower RGC loss with losartan was significantly less than the loss with spironolactone or enalapril (regression model p = 0.001; drug treatment group term p = 0.01. Both losartan and enalapril significantly lowered blood pressure (p< 0.001, but losartan was protective, while enalapril led to worse than water-treated RGC loss. RGC loss after crush injury was unaffected by losartan treatment (difference from control p = 0.9. Survival of RGC in cell culture was not prolonged by sartan treatment. Axonal transport blockade after 3 day IOP elevations was less in losartan-treated than in control glaucoma eyes (p = 0.007. Losartan inhibited effects of glaucoma, including reduction in extracellular signal-related kinase activity and modification of glaucoma-related changes in scleral thickness and creep under controlled IOP.The neuroprotective effect of losartan in mouse glaucoma is associated with adaptive changes in the sclera expressed at

  10. Retinal glutamate transporter changes in experimental glaucoma and after optic nerve transection in the rat.

    Science.gov (United States)

    Martin, Keith R G; Levkovitch-Verbin, Hana; Valenta, Danielle; Baumrind, Lisa; Pease, Mary Ellen; Quigley, Harry A

    2002-07-01

    High levels of glutamate can be toxic to retinal ganglion cells. Effective buffering of extracellular glutamate by retinal glutamate transporters is therefore important. This study was conducted to investigate whether glutamate transporter changes occur with two models of optic nerve injury in the rat. Glaucoma was induced in one eye of 35 adult Wistar rats by translimbal diode laser treatment to the trabecular meshwork. Twenty-five more rats underwent unilateral optic nerve transection. Two glutamate transporters, GLAST (EAAT-1) and GLT-1 (EAAT-2), were studied by immunohistochemistry and quantitative Western blot analysis. Treated and control eyes were compared 3 days and 1, 4, and 6 weeks after injury. Optic nerve damage was assessed semiquantitatively in epoxy-embedded optic nerve cross sections. Trabecular laser treatment resulted in moderate intraocular pressure (IOP) elevation in all animals. After 1 to 6 weeks of experimental glaucoma, all treated eyes had significant optic nerve damage. Glutamate transporter changes were not detected by immunohistochemistry. Western blot analysis demonstrated significantly reduced GLT-1 in glaucomatous eyes compared with control eyes at 3 days (29.3% +/- 6.7%, P = 0.01), 1 week (55.5% +/- 13.6%, P = 0.02), 4 weeks (27.2% +/- 10.1%, P = 0.05), and 6 weeks (38.1% +/- 7.9%, P = 0.01; mean reduction +/- SEM, paired t-tests, n = 5 animals per group, four duplicate Western blot analyses per eye). The magnitude of the reduction in GLT-1 correlated significantly with mean IOP in the glaucomatous eye (r(2) = 0.31, P = 0.01, linear regression). GLAST was significantly reduced (33.8% +/- 8.1%, mean +/- SEM) after 4 weeks of elevated IOP (P = 0.01, paired t-test, n = 5 animals per group). In contrast to glaucoma, optic nerve transection resulted in an increase in GLT-1 compared with the control eye (P = 0.01, paired t-test, n = 15 animals). There was no significant change in GLAST after transection. GLT-1 and GLAST were significantly

  11. First-in-human phase I study of ISTH0036, an antisense oligonucleotide selectively targeting transforming growth factor beta 2 (TGF-β2, in subjects with open-angle glaucoma undergoing glaucoma filtration surgery.

    Directory of Open Access Journals (Sweden)

    Norbert Pfeiffer

    Full Text Available To evaluate the safety and tolerability of intravitreal ISTH0036, an antisense oligonucleotide selectively targeting transforming growth factor beta 2 (TGF-β2, in patients with primary open angle glaucoma (POAG undergoing trabeculectomy (TE; glaucoma filtration surgery.In this prospective phase I trial glaucoma patients scheduled for TE with mitomycin C (MMC received a single intravitreal injection of ISTH0036 at the end of surgery in escalating total doses of 6.75 μg, 22.5 μg, 67.5 μg or 225 μg, resulting in calculated intraocular ISTH0036 concentrations in the vitreous humor of approximately 0.3 μM, 1 μM, 3 μM or 10 μM after injection, respectively. Outcomes assessed included: type and frequency of adverse events (AEs, intraocular pressure (IOP, numbers of interventions post trabeculectomy, bleb survival, visual acuity, visual field, electroretinogram (ERG, slit lamp biomicroscopy and optic disc assessment.In total, 12 patients were treated in the 4 dose groups. Main ocular AEs observed were corneal erosion, corneal epithelium defect, or too high or too low IOP, among others. No AE was reported to be related to ISTH0036. All other safety-related analyses did not reveal any toxicities of concern, either. The mean medicated preoperative IOP at decision time-point for surgery was 27.3 mmHg +/- 12.6 mmHg (SD. Mean IOP (±SD for dose levels 1, 2, 3, and 4 were at Day 43 9.8 mmHg ± 1.0 mmHg, 11.3 mmHg ± 6.7 mmHg, 5.5 mmHg ± 3.0 mmHg and 7.5 mmHg ± 2.3 mmHg SD; and at Day 85 9.7 mmHg ± 3.3 mmHg, 14.2 mmHg ± 6.5 mmHg, 5.8 mmHg ± 1.8 mmHg and 7.8 mmHg ± 0.6 mmHg, respectively. In contrast to IOP values for dose levels 1 and 2, IOP values for dose levels 3 and 4 persistently remained below 10 mmHg throughout the observation period.This first-in-human trial demonstrates that intravitreal injection of ISTH0036 at the end of TE is safe. Regarding IOP control, single-dose ISTH0036 administration of 67.5 μg or 225 μg at the time of TE

  12. Studies of Scleral Biomechanical Behavior Related to Susceptibility for Retinal Ganglion Cell Loss in Experimental Mouse Glaucoma

    Science.gov (United States)

    Nguyen, Cathy; Cone, Frances E.; Nguyen, Thao D.; Coudrillier, Baptiste; Pease, Mary E.; Steinhart, Matthew R.; Oglesby, Ericka N.; Jefferys, Joan L.; Quigley, Harry A.

    2013-01-01

    Purpose. To study anatomical changes and mechanical behavior of the sclera in mice with experimental glaucoma by comparing CD1 to B6 mice. Methods. Chronic experimental glaucoma for 6 weeks was produced in 2- to 4-month-old CD1 (43 eyes) and B6 mice (42 eyes) using polystyrene bead injection into the anterior chamber with 126 control CD1 and 128 control B6 eyes. Intraocular pressure (IOP) measurements were made with the TonoLab at baseline and after bead injection. Axial length and scleral thickness were measured after sacrifice in the CD1 and B6 animals and compared to length data from 78 eyes of DBA/2J mice. Inflation testing of posterior sclera was conducted, and circumferential and meridional strain components were determined from the displacement response. Results. Experimental glaucoma led to increases in axial length and width by comparison to fellow eyes (6% in CD1 and 10% in B6; all P glaucoma, the remainder of the sclera uniformly thinned in CD1, but thickened in B6. Peripapillary sclera in CD1 controls had significantly greater temporal meridional strain than B6 and had differences in the ratios of meridional to effective circumferential strain from B6 mice. In both CD1 and B6 mice, exposure to chronic IOP elevation resulted in stiffer pressure–strain responses for both the effective circumferential and meridional strains (multivariable regression model, P = 0.01–0.03). Conclusions. Longer eyes, greater scleral strain in some directions at baseline, and generalized scleral thinning after glaucoma were characteristic of CD1 mice that have greater tendency to retinal ganglion cell damage than B6 mice. Increased scleral stiffness after glaucoma exposure in mice mimics findings in monkey and human glaucoma eyes. PMID:23404116

  13. In Vivo Changes in Lamina Cribrosa Microarchitecture and Optic Nerve Head Structure in Early Experimental Glaucoma.

    Directory of Open Access Journals (Sweden)

    Kevin M Ivers

    Full Text Available The lamina cribrosa likely plays an important role in retinal ganglion cell axon injury in glaucoma. We sought to (1 better understand optic nerve head (ONH structure and anterior lamina cribrosa surface (ALCS microarchitecture between fellow eyes of living, normal non-human primates and (2 characterize the time-course of in vivo structural changes in the ONH, ALCS microarchitecture, and retinal nerve fiber layer thickness (RNFLT in non-human primate eyes with early experimental glaucoma (EG. Spectral domain optical coherence tomography (SDOCT images of the ONH were acquired cross-sectionally in six bilaterally normal rhesus monkeys, and before and approximately every two weeks after inducing unilateral EG in seven rhesus monkeys. ONH parameters and RNFLT were quantified from segmented SDOCT images. Mean ALCS pore area, elongation and nearest neighbor distance (NND were quantified globally, in sectors and regionally from adaptive optics scanning laser ophthalmoscope images. In bilaterally normal monkeys, ONH parameters were similar between fellow eyes with few inter-eye differences in ALCS pore parameters. In EG monkeys, an increase in mean ALCS Depth (ALCSD was the first structural change measured in 6 of 7 EG eyes. A decrease in mean minimum rim width (MRW simultaneously accompanied this early change in 4 of 6 EG eyes and was the first structural change in the 7th EG eye. Mean ALCS pore parameters were among the first or second changes measured in 4 EG eyes. Mean ALCS pore area and NND increased in superotemporal and temporal sectors and in central and peripheral regions at the first time-point of change in ALCS pore geometry. RNFLT and/or mean ALCS radius of curvature were typically the last parameters to initially change. Survival analyses found mean ALCSD was the only parameter to significantly show an initial change prior to the first measured loss in RNFLT across EG eyes.

  14. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-10-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent (/sup 57/Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity.

  15. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    International Nuclear Information System (INIS)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-01-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent ( 57 Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity

  16. The future of glaucoma surgery

    Directory of Open Access Journals (Sweden)

    Arsham Sheybani

    2015-01-01

    Full Text Available Glaucoma surgery is ripe for innovation. In the last few years, there has been a substantial increase in the number of devices approaching commercialization. While not all that is new is necessarily good, the role of these devices in changing glaucoma surgery is equally important in terms of both success and failure. Trabeculectomy, the most commonly performed incisional filtration surgery for glaucoma, is subjective by nature and certainly has risks. As devices aim to standardize glaucoma surgery, specifically subconjunctival filtration surgery, predictability and in turn safety should theoretically improve. This may allow the glaucoma surgeon to intervene earlier in the disease process, prevent more advanced vision loss and potentially decrease the burden of medications.

  17. Glaucoma Symptoms

    Science.gov (United States)

    ... up You can help find a cure for glaucoma Give now Signs & Symptoms The most common types ... have completely different symptoms. Symptoms of Open-Angle Glaucoma Most people who develop open-angle glaucoma don’ ...

  18. Clinicopathological correlation of parapapillary atrophy in monkeys with experimental glaucoma and temporary central retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Jost B Jonas

    2014-01-01

    Full Text Available Objective: To investigate the clinicopathological correlation of parapapillary atrophy. Materials and Methods: The study included 16 eyes of rhesus monkeys (Macaca mulatta - 4 eyes with experimental glaucoma, 11 eyes after experimental temporary occlusion of the central retinal artery, and 1 normal eye. On histological sections, we measured zones with different histological characteristics.On fundus photographs, alpha zone and beta zone of parapapillary atrophy were measured and correlated with the histological data. Results: The size of the clinical alpha zone of parapapillary atrophy was significantly correlated with the size of the histological region with irregularities of the retinal pigment epithelium (P = 0.05; correlation coefficient r = 0.49 and with the size of the histological region with a decreased density of retinal photoreceptors (P = 0.01; r = 0.60. The size of clinical beta zone of parapapillary atrophy significantly correlated with the size of the histological region with complete loss of the retinal pigment epithelium (P <0.001; r = 0.91, with the size of the histological zone with a complete loss of photoreceptors (P <0.001; r = 0.81, and with the size of the histological zone with a closed choriocapillaris (P <0.001; r = 0.89. Conclusions: The clinically seen alpha zone of parapapillary atrophy correlates with histological parapapillary irregularities of the retinal pigment epithelium and decreased density of retinal photoreceptors. The clinically seen beta zone of parapapillary atrophy correlates with histological complete loss of the retinal pigment epithelium and of the photoreceptors, and a closure of the choriocapillaris.

  19. [New directions in the hypotensive therapy of open-angle glaucoma (experimental and clinical research)].

    Science.gov (United States)

    Bunin, A Ia; Ermakov, V N; Filina, A A

    1993-01-01

    Clinical use of eye drops of a hybrid beta-alpha-adrenoblocker OF-4680 to reduce intraocular pressure has shown a high efficacy of the drug, not inferior to thymolol, for local hypotensive therapy of open-angle glaucoma. A combination of thymolol with taurin helped reduce the inhibiting effect of the beta-blocker on chamber humor secretion and simultaneously enhanced its discharge. The results evidence the desirability of correcting glutathion deficiency, detected in the patients with narrow-angle glaucoma, by lipoic acid.

  20. Rat optic nerve head anatomy within three- dimensional histomorphometric reconstructions of normal and early experimental glaucoma eyes

    OpenAIRE

    Pazos López, Marta

    2016-01-01

    Objetciu: Reconstruir en 3D caps del nervi òptic (CNOs) de rata camb glaucoma experimental (GExp) precoç unilateral, per proporcionar la primera descripció histomorfomètrica del CNO de controls normales i amb GExp primerenc en aquesta espècie. Métodos: Es va injectar sèrum salí hipertònic unilateralment en les venes epiesclerals de 8 rates noruegues que van ser sacrificades 4 setmantes després (fixació-perfusió). Cinc observadors enmascarats graduaren el dany de seccions del nervi òptic (NO) ...

  1. Effect of carboxymethylcellulose on the rheological and filtration properties of bentonite clay samples determined by experimental planning and statistical analysis

    Directory of Open Access Journals (Sweden)

    B. M. A. Brito

    Full Text Available Abstract Over the past few years, considerable research has been conducted using the techniques of mixture delineation and statistical modeling. Through this methodology, applications in various technological fields have been found/optimized, especially in clay technology, leading to greater efficiency and reliability. This work studied the influence of carboxymethylcellulose on the rheological and filtration properties of bentonite dispersions to be applied in water-based drilling fluids using experimental planning and statistical analysis for clay mixtures. The dispersions were prepared according to Petrobras standard EP-1EP-00011-A, which deals with the testing of water-based drilling fluid viscosifiers for oil prospecting. The clay mixtures were transformed into sodic compounds, and carboxymethylcellulose additives of high and low molar mass were added, in order to improve their rheology and filtrate volume. Experimental planning and statistical analysis were used to verify the effect. The regression models were calculated for the relation between the compositions and the following rheological properties: apparent viscosity, plastic viscosity, and filtrate volume. The significance and validity of the models were confirmed. The results showed that the 3D response surfaces of the compositions with high molecular weight carboxymethylcellulose added were the ones that most contributed to the rise in apparent viscosity and plastic viscosity, and that those with low molecular weight were the ones that most helped in the reduction of the filtrate volume. Another important observation is that the experimental planning and statistical analysis can be used as an important auxiliary tool to optimize the rheological properties and filtrate volume of bentonite clay dispersions for use in drilling fluids when carboxymethylcellulose is added.

  2. Facts about Glaucoma

    Science.gov (United States)

    ... Information » Glaucoma » Facts About Glaucoma Listen Facts About Glaucoma This information was developed by the National Eye ... is the best person to answer specific questions. Glaucoma Defined What is Glaucoma? Glaucoma is a group ...

  3. Glaucoma: Symptoms and Causes

    Science.gov (United States)

    ... types of glaucoma include the following: Open-angle glaucoma Open-angle glaucoma is the most common form ... re even aware of a problem. Angle-closure glaucoma Angle-closure glaucoma, also called closed-angle glaucoma, ...

  4. Movement of retinal vessels toward the optic nerve head after increasing intraocular pressure in monkey eyes with experimental glaucoma.

    Science.gov (United States)

    Kuroda, Atsumi; Enomoto, Nobuko; Ishida, Kyoko; Shimazawa, Masamitsu; Noguchi, Tetsuro; Horai, Naoto; Onoe, Hirotaka; Hara, Hideaki; Tomita, Goji

    2017-09-01

    A shift or displacement of the retinal blood vessels (RBVs) with neuroretinal rim thinning indicates the progression of glaucomatous optic neuropathy. In chronic open angle glaucoma, individuals with RBV positional shifts exhibit more rapid visual field loss than those without RBV shifts. The retinal vessels reportedly move onto the optic nerve head (ONH) in response to glaucoma damage, suggesting that RBVs are pulled toward the ONH in response to increased cupping. Whether this phenomenon only applies to RVBs located in the vicinity or inside the ONH or, more generally, to RBVs also located far from the ONH, however, is unclear. The aim of this study was to evaluate the movement of RBVs located relatively far from the ONH edge after increasing intraocular pressure (IOP) in an experimental monkey model of glaucoma. Fundus photographs were obtained in 17 monkeys. High IOP was induced in the monkeys by laser photocoagulation burns applied uniformly with 360° irradiation around the trabecular meshwork of the left eye. The right eye was left intact and used as a non-treated control. Considering the circadian rhythm of IOP, it was measured in both eyes of each animal at around the same time-points. Then, fundus photographs were obtained. Using Image J image analysis software, an examiner (N.E.) measured the fundus photographs at two time-points, i.e. before laser treatment (time 1) and the last fundus photography after IOP elevation (time 2). The following parameters were measured (in pixels): 1) vertical diameter of the ONH (DD), 2) distance from the ONH edge to the first bifurcation point of the superior branch of the central retinal vein (UV), 3) distance from the ONH edge to the first bifurcation point of the inferior branch of the central retinal vein (LV), 4) ONH area, and 5) surface area of the cup of the ONH. We calculated the ratios of UV to DD (UV/DD), LV to DD (LV/DD), and the cup area to disc area ratio (C/D). The mean UV/DD at time 1 (0.656 ± 0.233) was

  5. Glaucoma (image)

    Science.gov (United States)

    Glaucoma is a condition of increased fluid pressure inside the eye. The increased pressure causes compression of ... nerve which can eventually lead to nerve damage. Glaucoma can cause partial vision loss, with blindness as ...

  6. Glaucoma Foundation

    Science.gov (United States)

    ... Options: SIZE CONTRAST Search Home About TGF About Glaucoma About Exfoliation Syndrome Research Center Contact Us Get ... tear glands, and a common preservative in many glaucoma medications can worsen the symptoms. The main treatment ...

  7. Experimental microendoscopic photoablative laser goniotomy as a surgical model for the treatment of dysgenetic glaucoma.

    Science.gov (United States)

    Jacobi, P C; Dietlein, T S; Krieglstein, G K

    1996-11-01

    The aim of this study was to investigate the feasibility of photoablative Er:YAG laser goniotomy under microendoscopic control in a surgical cloudy corneal model of primary infantile glaucoma. Pectinate ligaments of 12 freshly enucleated cadaver porcine eyes were treated by ab interno single-pulse (5 mJ, 200 microseconds) Er:YAG laser (2.94 microns) photoablation. Through a clear corneal incision near the limbus an ophthalmic microendoscope (18 and 20 gauge) was inserted into the anterior chamber. Internal structures were observed and photoablative laser goniotomy was conducted under video guidance. Following treatment all eyes were prepared for light and scanning electron microscopy. Anterior chamber angle structures and tissue photoablation were clearly visualized on the videoscreen using ophthalmic microendoscopy. Energy settings of 5 mJ per pulse proved to be sufficient for reproducible photoablation of pectinate ligaments, accompanied by the root of the iris falling back and exposing trabecular meshwork. This was confirmed histopathologically. Scatter thermal damage was less than 30 microns. This new therapeutic modality, which combines endoscopic visualization of the internal structures with photoablative laser goniotomy, can be effective in the management of dysgenetic glaucoma in the presence of a cloudy cornea. High reproducibility of contact laser photoablation enabled sufficient control of incision depth and was not accompanied by inadvertent tissue damage to adjacent intraocular structures.

  8. Integrin α5β1 Inhibition by CLT-28643 Reduces Postoperative Wound Healing in a Mouse Model of Glaucoma Filtration Surgery.

    Science.gov (United States)

    Van Bergen, Tine; Zahn, Grit; Caldirola, Patrizia; Fsadni, Mario; Caram-Lelham, Ninus; Vandewalle, Evelien; Moons, Lieve; Stalmans, Ingeborg

    2016-11-01

    To evaluate the therapeutic potential of the small molecule integrin α5β1 inhibitor, CLT-28643, to improve the filtering surgery outcome in a mouse model. Different dose regimens and administration routes of the inhibitor were compared with mitomycin C (MMC), the gold standard in clin ical practice. The efficacy of CLT-28643 on surgical outcome was studied in a mouse model for filtering surgery (n = 40 eyes from 20 mice per group). Single and repeated subconjunctival (SCJ) injections (1 or 2 μg) and topical eye drops (10 μg) of the integrin inhibitor were compared with 2-minute administration of MMC 0.02%. Bleb size, survival, and signs of toxicity were examined until 28 days after surgery. Immunohistochemical analysis of angiogenesis, inflammation, collagen deposition, and integrin α5β1 expression were performed on postoperative days 3, 8, 14, and 28. A masked observer performed all the assessments. Immunostaining showed that integrin α5β1 was highly expressed in the bleb at early time-points after surgery and that CLT-28643 inhibited this upregulation. Efficacy was shown to be dose-dependent for the integrin inhibitor CLT-28643 for bleb area and survival, and the wound healing process. While 2-μg single injection of CLT-28643 improved bleb characteristics in a similar way as 10-μg administered by eye drops and MMC, repeated injections of 2 μg showed superior efficacy compared to MMC, with no corneal toxicity. Administration of the integrin α5β1 inhibitor CLT-28643 has therapeutic potential as an adjunct to glaucoma surgery, possibly with a superior efficacy and tolerability compared with MMC when used at the optimal dose.

  9. Rheological and filtration characteristics of drilling fluids enhanced by nanoparticles with selected additives: an experimental study

    Directory of Open Access Journals (Sweden)

    Nima Mohamadian

    2018-05-01

    Full Text Available The suspension properties of drilling fluids containing pure and polymer-treated (partially-hydrolyzed polyacrylamide (PHPA or Xanthan gum clay nanoparticles are compared withthose of a conventional water-and-bentonite-based drilling fluid, used as the referencesample. Additionally, the mud weight, plastic viscosity, apparent viscosity, yield point, primary and secondary gelatinization properties, pH, and filtration properties of the various drilling fluids studied are also measured and compared. The performance of each drilling fluid type is evaluated with respect in terms of its ability to reduce mud cake thickness and fluid loss thereby inhibiting differential-pipe-sticking. For that scenario, the mud-cake thickness is varied, and the filtration properties of the drilling fluids are measured as an indicator of potential well-diameter reduction, caused by mud cake, adjacent to permeable formations. The novel results show that nanoparticles do significantly enhance the rheological and filtration characteristics of drilling fluids. A pure-clay-nanoparticle suspension, without any additives, reduced fluid loss to about 42% and reduced mud cake thickness to 30% compared to the reference sample. The xanthan-gum-treated-clay-nanoparticle drilling fluid showed good fluid loss control and reduced fluid loss by 61% compared to the reference sample. The presence of nanofluids also leads to reduced mud-cake thicknesses, directly mitigating the risks of differential pipe sticking.

  10. The Connective Tissue Components of Optic Nerve Head Cupping in Monkey Experimental Glaucoma Part 1: Global Change

    Science.gov (United States)

    Yang, Hongli; Ren, Ruojin; Lockwood, Howard; Williams, Galen; Libertiaux, Vincent; Downs, Crawford; Gardiner, Stuart K.; Burgoyne, Claude F.

    2015-01-01

    Purpose To characterize optic nerve head (ONH) connective tissue change within 21 monkey experimental glaucoma (EG) eyes, so as to identify its principal components. Methods Animals were imaged three to five times at baseline then every 2 weeks following chronic unilateral IOP elevation, and euthanized early through end-stage confocal scanning laser tomographic change. Optic nerve heads were serial-sectioned, three-dimensionally (3D) reconstructed, delineated, and quantified. Overall EG versus control eye differences were assessed by general estimating equations (GEE). Significant, animal-specific, EG eye change was required to exceed the maximum physiologic intereye differences in six healthy animals. Results Overall EG eye change was significant (P connective tissue components of ONH “cupping” in monkey EG which serve as targets for longitudinally staging and phenotyping ONH connective tissue alteration within all forms of monkey and human optic neuropathy. PMID:26641545

  11. Glaucoma Research Foundation

    Science.gov (United States)

    ... born with glaucoma. Read her story » Learn About Glaucoma Glaucoma is a complicated disease in which damage ... Christopher doesn't ever want to go blind » Glaucoma 360 Glaucoma 360 — three days of events uniting ...

  12. Neuroprotection in glaucoma

    Directory of Open Access Journals (Sweden)

    Azadeh Doozandeh

    2016-01-01

    Full Text Available Glaucoma is a degenerative optic neuropathy characterized by retinal ganglion cell (RGC loss and visual field defects. It is known that in some glaucoma patients, death of RGCs continues despite intraocular pressure (IOP reduction. Neuroprotection in the field of glaucoma is defined as any treatment, independent of IOP reduction, which prevents RGC death. Glutamate antagonists, ginkgo biloba extract, neurotrophic factors, antioxidants, calcium channel blockers, brimonidine, glaucoma medications with blood regulatory effect and nitric oxide synthase inhibitors are among compounds with possible neuroprotective activity in preclinical studies. A few agents (such as brimonidine or memantine with neuroprotective effects in experimental studies have advanced to clinical trials; however the results of clinical trials for these agents have not been conclusive. Nevertheless, lack of compelling clinical evidence has not prevented the off-label use of some of these compounds in glaucoma practice. Stem cell transplantation has been reported to halt experimental neurodegenerative disease processes in the absence of cell replacement. It has been hypothesized that transplantation of some types of stem cells activates multiple neuroprotective pathways via secretion of various factors. The advantage of this approach is a prolonged and targeted effect. Important concerns in this field include the secretion of unwanted harmful mediators, graft survival issues and tumorigenesis. Neuroprotection in glaucoma, pharmacologically or by stem cell transplantation, is an interesting subject waiting for broad and multidisciplinary collaborative studies to better clarify its role in clinical practice.

  13. Equine Glaucoma.

    Science.gov (United States)

    Michau, Tammy Miller

    2017-12-01

    Glaucoma is a multifactorial neurodegenerative ocular disease leading to progressive loss of retinal ganglion cells and their axons that form the optic nerve, causing blindness. Knowledge of the pathogenesis and development of equine glaucoma is in its infancy compared with human glaucoma. Glaucoma occurs most commonly secondary to uveitis and may be underdiagnosed or misdiagnosed in horses suffering from uveitis. Recognition and clinical diagnosis of glaucoma in the horse is improved with clinician awareness and the availability of handheld tonometers. Therapy for glaucoma is aimed at decreasing aqueous humor production through medical and surgical means. Even with therapy, long-term prognosis for vision is poor. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. A Review of the Ahmed Glaucoma Valve Implant and Comparison with Other Surgical Operations.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Katsanos, Andreas; Oddone, Francesco; Quaranta, Luciano

    2017-04-01

    The Ahmed glaucoma valve (AGV) is a popular glaucoma drainage implant used for the control of intraocular pressure in patients with glaucoma. While in the past AGV implantation was reserved for glaucoma patients poorly controlled after one or more filtration procedures, mounting evidence has recently encouraged its use as a primary surgery in selected cases. AGV has been demonstrated to be safe and effective in reducing intraocular pressure in patients with primary or secondary refractory glaucoma. Compared to other glaucoma surgeries, AGV implantation has shown favorable efficacy and safety. The aim of this article is to review the results of studies directly comparing AGV with other surgical procedures in patients with glaucoma.

  15. Experimental results of rectification and filtration from an offshore wave energy system

    Energy Technology Data Exchange (ETDEWEB)

    Bostroem, C.; Staalberg, M.; Thorburn, K.; Leijon, M. [Swedish Centre for Renewable Electric Energy Conversion, Division for Electricity Research, Department of Engineering Science, Uppsala University, Box 534, 75121 Uppsala (Sweden); Lejerskog, E. [Seabased Industry AB, Dag Hammarskjoelds vaeg 52b, 75183 Uppsala (Sweden)

    2009-05-15

    The present paper presents results from a wave energy conversion that is based on a direct drive linear generator. The linear generator is placed on the seabed and connected to a buoy via a rope. Thereby, the natural wave motion is transferred to the translator by the buoy motion. When using direct drive generators, voltage and current output will have varying frequency and varying amplitude and the power must be converted before a grid connection. The electrical system is therefore an important part to study in the complete conversion system from wave energy to grid connected power. This paper will bring up the first steps in the conversion: rectification and filtration of the power. Both simulation studies and offshore experiments have been made. The results indicate that this kind of system works in a satisfactory way and a smooth DC power can be achieved with one linear generator. (author)

  16. Pediatric glaucoma: current perspectives

    Directory of Open Access Journals (Sweden)

    Marchini G

    2014-05-01

    Full Text Available Giorgio Marchini, Marco Toscani, Francesca Chemello Eye Clinic, Department of Neurological and Movement Sciences, University of Verona, Verona, Italy Abstract: “Childhood glaucoma” is a heterogeneous group of severe pediatric conditions often associated with significant visual loss and characterized by elevated intraocular pressure (IOP and optic-disk cupping. Successful IOP control is crucial but challenging and most often achieved surgically, with medical therapy playing a supportive role. There are many classifications of childhood glaucoma, but they can simply be divided into primary, in which a developmental abnormality of the anterior chamber angle only exists, and secondary, in which aqueous outflow is reduced due to independent mechanisms that secondarily impair the function of the filtration angle. The worldwide prevalence of childhood blindness ranges from 0.03% in high-income countries to 0.12% in undeveloped countries. The majority of cases do not have an identified genetic mutation and, where the mutation is known, the genes often account for only a small proportion of cases. Several pathogenetic mechanisms are known to contribute to the development of childhood glaucoma. Whatever the cause, it results in a reduced aqueous outflow at the level of the trabecular meshwork. Age of onset and magnitude of the elevated IOP largely determine the clinical manifestation the high variability of clinical manifestations. Glaucoma from any cause in a neonate and infant is characterized by the classic triad of epiphora, photophobia, and blepharospasm, and could be associated with eye enlargement (buphthalmos and Haab striae. The eye examination, usually performed under general anesthesia, includes: tonometry, anterior-segment examination, gonioscopy, corneal diameter and axial length measurement, dilated fundoscopy with optic-nerve-head evaluation. Medical therapy, considering the high frequency of side effects, is generally used as

  17. Expansions of the neurovascular scleral canal and contained optic nerve occur early in the hypertonic saline rat experimental glaucoma model.

    Science.gov (United States)

    Pazos, Marta; Yang, Hongli; Gardiner, Stuart K; Cepurna, William O; Johnson, Elaine C; Morrison, John C; Burgoyne, Claude F

    2016-04-01

    To characterize early optic nerve head (ONH) structural change in rat experimental glaucoma (EG). Unilateral intraocular pressure (IOP) elevation was induced in Brown Norway rats by hypertonic saline injection into the episcleral veins and animals were sacrificed 4 weeks later by perfusion fixation. Optic nerve cross-sections were graded from 1 (normal) to 5 (extensive injury) by 5 masked observers. ONHs with peripapillary retina and sclera were embedded, serial sectioned, 3-D reconstructed, delineated, and quantified. Overall and animal-specific EG versus Control eye ONH parameter differences were assessed globally and regionally by linear mixed effect models with significance criteria adjusted for multiple comparisons. Expansions of the optic nerve and surrounding anterior scleral canal opening achieved statistical significance overall (p < 0.0022), and in 7 of 8 EG eyes (p < 0.005). In at least 5 EG eyes, significant expansions (p < 0.005) in Bruch's membrane opening (BMO) (range 3-10%), the anterior and posterior scleral canal openings (8-21% and 5-21%, respectively), and the optic nerve at the anterior and posterior scleral canal openings (11-30% and 8-41%, respectively) were detected. Optic nerve expansion was greatest within the superior and inferior quadrants. Optic nerve expansion at the posterior scleral canal opening was significantly correlated to optic nerve damage (R = 0.768, p = 0.042). In the rat ONH, the optic nerve and surrounding BMO and neurovascular scleral canal expand early in their response to chronic experimental IOP elevation. These findings provide phenotypic landmarks and imaging targets for detecting the development of experimental glaucomatous optic neuropathy in the rat eye. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. What Is Glaucoma?

    Science.gov (United States)

    ... Stories Español Eye Health / Eye Health A-Z Glaucoma Sections What Is Glaucoma? What Are the Symptoms ... Diagnosis Glaucoma Treatment Glaucoma Vision Simulator What Is Glaucoma? Leer en Español: ¿Qué es el glaucoma? Written ...

  19. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Ying, T.Y.; Chin, C.J.; Lu, S.C.; Yiacoumi, S.

    1997-10-01

    Magnetic-seeding filtration consists of two steps: heterogeneous particle flocculation of magnetic and nonmagnetic particles in a stirred tank and high-gradient magnetic filtration (HGMF). The effects of various parameters affecting magnetic-seeding filtration (HGMF). The effects of various parameters affecting magnetic seeding filtration are theoretically and experimentally investigated. A trajectory model that includes hydrodynamic resistance, van der Waals, and electrostatic forces is developed to calculate the flocculation frequency in a turbulent-shear regime. Fractal dimension is introduced to simulate the open structure of aggregates. A magnetic-filtration model that consists of trajectory analysis, a particle build-up model, a breakthrough model, and a bivariate population-balance model is developed to predict the breakthrough curve of magnetic-seeding filtration. A good agreement between modeling results and experimental data is obtained. The results show that the model developed in this study can be used to predict the performance of magnetic-seeding filtration without using empirical coefficients or fitting parameters. 35 refs., 7 figs., 1 tab

  20. UBM-guided chamber angle surgery for glaucoma management: an experimental study.

    Science.gov (United States)

    Dietlein, T S; Engels, B F; Jacobi, P C; Krieglstein, G K

    2003-04-01

    The aim of this experimental study was to investigate the potential of ultrasound bimicroscopy (UBM)-guided chamber angle surgery as an alternative or supplement to gonioscopy and intraocular microendoscopy for intraoperative control. In 15 porcine cadaver eyes, mechanical goniopuncture or punctual Er:YAG laser trabecular ablation was performed without operating microscope or gonioscopy, but with real-life ultrasound biomicroscopy monitoring with a 50 MHz transducer. Intraoperative localization of the microsurgical instruments and tissue-instrument contact were qualitatively evaluated. The instruments could be clearly visualized within the chamber angle and disturbing artefacts were only minimal when using mechanically fixed instruments in slow motion. Topographic localization, tissue contact, and penetration depth of the instruments entering the scleral were well illustrated as far as the technical resolution limits of UBM would allow. UBM can be used intraoperatively to monitor the correct manoeuvring of microsurgical instruments in selected ab interno procedures. Some adaptations and further modifications of the technique presented here will be necessary before UBM-guided surgery can be considered for clinical use in humans.

  1. Glaucoma, Open-Angle

    Science.gov (United States)

    ... Home » Statistics and Data » Glaucoma, Open-angle Listen Glaucoma, Open-angle Open-angle Glaucoma Defined In open-angle glaucoma, the fluid passes ... 2010 2010 U.S. Age-Specific Prevalence Rates for Glaucoma by Age and Race/Ethnicity The prevalence of ...

  2. Experimental investigation of the formaldehyde removal mechanisms in a dynamic botanical filtration system for indoor air purification.

    Science.gov (United States)

    Wang, Zhiqiang; Pei, Jingjing; Zhang, Jensen S

    2014-09-15

    Botanical filtration has been proved to be effective for indoor gas pollutant removal. To understand the roles of different transport, storage and removal mechanism by a dynamic botanical air filter, a series of experimental investigations were designed and conducted in this paper. Golden Pothos (Epipremnum aureum) plants was selected for test, and its original soil or activated/pebbles root bed was used in different test cases. It was found that flowing air through the root bed with microbes dynamically was essential to obtain meaningful formaldehyde removal efficiency. For static potted plant as normally place in rooms, the clean air delivery rate (CADR), which is often used to quantify the air cleaning ability of portable air cleaners, was only ∼ 5.1m(3)/h per m(2) bed, while when dynamically with air flow through the bed, the CADR increased to ∼ 233 m(3)/h per m(2) bed. The calculated CADR due to microbial activity is ∼ 108 m(3)/h per m(2) bed. Moisture in the root bed also played an important role, both for maintaining a favorable living condition for microbes and for absorbing water-soluble compounds such as formaldehyde. The role of the plant was to introduce and maintain a favorable microbe community which effectively degraded the volatile organic compounds adsorbed or absorbed by the root bed. The presence of the plant increased the removal efficiency by a factor of two based on the results from the bench-scale root bed experiments. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Glaucoma: Symptoms, Diagnosis & Treatment

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Symptoms, Treatment and Research Past Issues / Spring 2015 ... vision, without any pain. Photo courtesy of NEI Glaucoma Symptoms At first, open-angle glaucoma has no ...

  4. Get Tested for Glaucoma!

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Get Tested for Glaucoma! Past Issues / Fall 2009 Table of Contents Taylor ... aoa.org/ When were you finally diagnosed with glaucoma? Not until 1969, after a game of basketball. ...

  5. Filtration in Porous Media

    DEFF Research Database (Denmark)

    Yuan, Hao; Shapiro, Alexander

    There is a considerable and ongoing effort aimed at understanding the transport and the deposition of suspended particles in porous media, especially non-Fickian transport and non-exponential deposition of particles. In this work, the influential parameters in filtration models are studied...... to understand their effects on the non-Fickian transport and the non-exponential deposition. The filtration models are validated by the comparisons between the modelling results and the experimental data.The elliptic equation with distributed filtration coefficients may be applied to model non-Fickian transport...... and hyperexponential deposition. The filtration model accounting for the migration of surface associated particles may be applied for non-monotonic deposition....

  6. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  7. Experimental study on filtration and continuous regeneration of a particulate filter system for heavy-duty diesel engines.

    Science.gov (United States)

    Tang, Tao; Zhang, Jun; Cao, Dongxiao; Shuai, Shijin; Zhao, Yanguang

    2014-12-01

    This study investigated the filtration and continuous regeneration of a particulate filter system on an engine test bench, consisting of a diesel oxidation catalyst (DOC) and a catalyzed diesel particulate filter (CDPF). Both the DOC and the CDPF led to a high conversion of NO to NO2 for continuous regeneration. The filtration efficiency on solid particle number (SPN) was close to 100%. The post-CDPF particles were mainly in accumulation mode. The downstream SPN was sensitively influenced by the variation of the soot loading. This phenomenon provides a method for determining the balance point temperature by measuring the trend of SPN concentration. Copyright © 2014. Published by Elsevier B.V.

  8. Neuroprotection in glaucoma

    Science.gov (United States)

    Vasudevan, Sushil K; Gupta, Viney; Crowston, Jonathan G

    2011-01-01

    Glaucoma is a neurodegenerative disease characterized by loss of retinal ganglion cells and their axons. Recent evidence suggests that intraocular pressure (IOP) is only one of the many risk factors for this disease. Current treatment options for this disease have been limited to the reduction of IOP; however, it is clear now that the disease progression continues in many patients despite effective lowering of IOP. In the search for newer modalities in treating this disease, much data have emerged from experimental research the world over, suggesting various pathological processes involved in this disease and newer possible strategies to treat it. This review article looks into the current understanding of the pathophysiology of glaucoma, the importance of neuroprotection, the various possible pharmacological approaches for neuroprotection and evidence of current available medications. PMID:21150020

  9. Does optic nerve head surface topography change prior to loss of retinal nerve fiber layer thickness: a test of the site of injury hypothesis in experimental glaucoma.

    Directory of Open Access Journals (Sweden)

    Brad Fortune

    Full Text Available To test the hypothesis that optic nerve head (ONH deformation manifesting as changes in its mean surface height precedes thinning of the peripapillary retinal nerve fiber layer (RNFL in experimental glaucoma (EG.68 rhesus macaque monkeys each had three or more baseline imaging sessions under manometric intraocular pressure (IOP control to obtain average RNFL thickness (RNFLT and the ONH surface topography parameter mean position of the disc (MPD. Laser photocoagulation was then applied to the trabecular meshwork of one eye to induce chronic, mild-to-moderate IOP elevation and bi-weekly imaging continued. Event analysis was applied to determine for each parameter when an 'endpoint' occurred (signficant change from baseline for eight different endpoint criteria. Specificity was assessed in the group of 68 fellow control eyes. Classical signal detection theory and survival analysis were used to compare MPD with RNFLT.Regardless of the endpoint criterion, endpoints were always more frequent for MPD than for RNFLT. The discriminability index (d' was 2.7 ± 0.2 for MPD and 1.9 ± 0.2 for RNFLT (p<0.0001. Endpoints were reached by MPD an average of 1-2 months earlier than by RNFLT (p<0.01. At the onset of the first specific, detectable MPD change in EG eyes, there was still no significant change in RNFLT on average (p=0.29 and only 25% of individual eyes exhibited signficant reduction. In contrast, at onset of signficant RNFLT change, MPD had already changed an average of 101 µm from baseline (p<0.0001 and 71% of the individual eyes had exhibited significant change. The magnitude of MPD change was more than could be explained on the basis of axon loss alone.This study demonstrates that the average surface height of the ONH changes prior to any detectable loss of average peripapillary RNFL thickness in non-human primate eyes with experimental glaucoma.

  10. Filtration by eyelashes

    Science.gov (United States)

    Vistarakula, Krishna; Bergin, Mike; Hu, David

    2010-11-01

    Nearly every mammalian and avian eye is rimmed with lashes. We investigate experimentally the ability of lashes to reduce airborne particle deposition in the eye. We hypothesize that there is an optimum eyelash length that maximizes both filtration ability and extent of peripheral vision. This hypothesis is tested using a dual approach. Using preserved heads from 36 species of animals at the American Museum of Natural History, we determine the relationship between eye size and eyelash geometry (length and spacing). We test the filtration efficacy of these geometries by deploying outdoor manikins and measuring particle deposition rate as a function of eyelash length.

  11. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1982-01-01

    Significant developments in high-efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include (1) factory (bench) and in-place test methods, (2) new developments in paper and filter unit construction methods, (3) vented containment air cleaning systems for liquid-metal fast breeder reactors and light-water-moderated reactors, and (4) decontamination of off-gases from nuclear waste volume-reduction processes. Standards development has been vigorously pursued during this period, but advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of high-efficiency particulate air filters instead of those which have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge

  12. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1981-01-01

    Significant developments in high efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include factory (bench) and in-place test methods, new developments in paper and filter unit construction methods, vented containment air cleaning systems for LMFBR and light water moderated reactors, and decontamination of offgases from nuclear waste volume reduction processes. It is noted that standards development has been vigorously pursued during this period but that advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of HEPA filters for those that have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge. 71 references

  13. Filtration and compression of organic materials

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Keiding, Kristian

    is to use more simple systems. Dextran-MnO2 particles and polystyrene particles with a water-swollen polyacrylic acid shell have therefore been synthesised. These particles have been filtered and used to study the non-linear filtration behaviour. The compressibility of the formed cake has been investigated......The conventional filtration theory has been based on filtrations of incompressible particles such as anatase, kaolin and clay. The filtration models have later been used for organic slurries but can often not explain the observed experimental data. At constant pressure, the filtrate volume does...... and the discrepancy between the filtration theory and the observed filtration behaviour explained as a time-dependent collapse of the formed cake (creep). Thus, the creep phenomenon has been adopted in the conventional filtration models and it will be shown that the model can be used to simulate filtration data...

  14. Effectiveness of Membrane Filtration to Improve Drinking Water: A Quasi-Experimental Study from Rural Southern India.

    Science.gov (United States)

    Francis, Mark Rohit; Sarkar, Rajiv; Roy, Sheela; Jaffar, Shabbar; Mohan, Venkata Raghava; Kang, Gagandeep; Balraj, Vinohar

    2016-11-02

    Since point-of-use methods of water filtration have shown limited acceptance in Vellore, southern India, this study evaluated the effectiveness of decentralized membrane filtration 1) with safe storage, 2) without safe storage, versus 3) no intervention, consisting of central chlorination as per government guidelines, in improving the microbiological quality of drinking water and preventing childhood diarrhea. Periodic testing of water sources, pre-/postfiltration samples, and household water, and a biweekly follow up of children less than 2 years of age was done for 1 year. The membrane filters achieved a log reduction of 0.86 (0.69-1.06), 1.14 (0.99-1.30), and 0.79 (0.67-0.94) for total coliforms, fecal coliforms, and Escherichia coli, respectively, in field conditions. A 24% (incidence rate ratio, IRR [95% confidence interval, CI] = 0.76 [0.51-1.13]; P = 0.178) reduction in diarrheal incidence in the intervention village with safe storage and a 14% (IRR [95% CI] = 1.14 [0.75-1.77]; P = 0.530) increase in incidence for the intervention village without safe storage versus no intervention village was observed, although not statistically significant. Microbiologically, the membrane filters decreased fecal contamination; however, provision of decentralized membrane-filtered water with or without safe storage was not protective against childhood diarrhea. © The American Society of Tropical Medicine and Hygiene.

  15. Aerosol filtration

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.; De Smet, M.; Trine, J.; Hertschap, M.

    1984-01-01

    This report summarizes the work on the development of fibre metallic prefilters to be placed upstream of HEPA filters for the exhaust gases of nuclear process plants. Investigations at ambient and high temperature were carried out. Measurements of the filtration performance of Bekipor porous webs and sintered mats were performed in the AFLT (aerosol filtration at low temperature) unit with a throughput of 15 m 3 /h. A parametric study on the influence of particle size, fibre diameter, number of layers and superficial velocity led to the optimum choice of the working parameters. Three selected filter types were then tested with polydisperse aerosols using a candle-type filter configuration or a flat-type filter configuration. The small-diameter candle type is not well suited for a spraying nozzles regeneration system so that only the flat-type filter was retained for high-temperature tests. A high-temperature test unit (AFHT) with a throughput of 8 to 10 m 3 /h at 400 0 C was used to test the three filter types with an aerosol generated by high-temperature calcination of a simulated nitric acid waste solution traced with 134 Cs. The regeneration of the filter by spray washing and the effect of the regeneration on the filter performance was studied for the three filter types. The porous mats have a higher dust loading capacity than the sintered web which means that their regeneration frequency can be kept lower

  16. Glaucoma in Asian Populations

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Glaucoma In Asian Populations email Send this article to ... lower than in their Asian counterparts. Normal Tension Glaucoma affects Japanese Japanese populations, however, have a substantially ...

  17. African Americans and Glaucoma

    Science.gov (United States)

    ... Us Donate In This Section African Americans and Glaucoma email Send this article to a friend by ... and eventually, in developing more effective treatments. Does glaucoma treatment differ? Although treatment varies for all individuals, ...

  18. Screening for Glaucoma

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Glaucoma The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Glaucoma . This final recommendation statement ...

  19. Five Common Glaucoma Tests

    Science.gov (United States)

    ... About Us Donate In This Section Five Common Glaucoma Tests en Español email Send this article to ... year or two after age 35. A Comprehensive Glaucoma Exam To be safe and accurate, five factors ...

  20. THE GONIOSETON, A SURGICAL-TREATMENT FOR CHRONIC GLAUCOMA

    NARCIS (Netherlands)

    VANDERVEEN, G; JONGEBLOED, WL; WORST, JGF

    1990-01-01

    A new and simple technique for glaucoma filtering surgery is presented. It is based on the introduction of a stainless steel microspiral or gonioseton into a goniopuncture by way of an ab interno procedure, minimising surgical trauma to the filtration area. Preliminary results are presented.

  1. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  2. Glaucoma Medication Preferences among Glaucoma Specialists in Mexico

    OpenAIRE

    Lazcano-Gomez, Gabriel; Alvarez-Ascencio, Daniela; Haro-Zuno, Cindy; Turati-Acosta, Mauricio; Garcia-Huerta, Magdalena; Jimenez-Arroyo, Jesus; Castañeda-Diez, Rafael; Castillejos-Chevez, Armando; Gonzalez-Salinas, Roberto; Dominguez-Dueñas, Francisca; Jimenez-Roman, Jesus

    2017-01-01

    Aim To determine the glaucoma specialists’ preferences for the different brands of topical glaucoma medications available in Mexico. Materials and methods A web-based survey was sent to 150 board-certified glaucoma specialists in Mexico, with 14 questions related to brand preferences for all glaucoma medications available in Mexico. Participants were asked to select each glaucoma medication class by brand and to state the factors leading to their choice. Results Data from 111 (74%) glaucoma s...

  3. Optimization of filtration for the reduction of lung dose from Rn decay products: Part II--Experimental

    International Nuclear Information System (INIS)

    Curling, C.A.; Rudnick, S.N.; Harrington, D.P.; Moeller, D.W.

    1990-01-01

    Research was performed to determine the validity of a model developed to theoretically predict the optimal characteristics of a recirculating filter system for minimizing the lung dose to a person breathing airborne Rn progeny. Four designs, each with different filter thicknesses, solidities, and fiber diameters, were tested to evaluate the accuracy of the model over a range of parameters. Increasing thicknesses were then tested for the most effective filter design to provide a more definitive comparison of experimental data and model predictions for this key parameter. The experimental data supported the conclusion that the most effective design was a thin filter of low solidity composed of coarse fibers. Although the maximum reduction in the dose-equivalent rate observed in these experiments was 50%, this was largely due to constraints on the experimental arrangements. With properly constructed filter units, much better removal efficiencies can undoubtedly be achieved

  4. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  5. Filtration of polydispersed colloids

    International Nuclear Information System (INIS)

    Nuttall, H.E.

    1988-01-01

    In this study, the dynamic microscopic form of the population balance model is applied to the problem of polydispersed particle capture in one spatial diffusion. This mathematical modeling approach can be applied to the difficult and potentially important problem of particulate (radiocolloid) transport in the groundwater surrounding a nuclear waste disposal site. To demonstrate the population balance methodology, the equations were developed and used to investigate transport and capture of polydispersed colloids in packed columns. Modeling simulations were compared to experimental column data. The multidimensional form of the population balance equation was used to analyze the transport and capture of polydispersed colloids. A numerical model was developed to describe transport of polydispersed colloids through a one-dimensional porous region. The effects of various size distributions were investigated in terms of capture efficiency. For simulating the column data, it was found by trial and error that as part of the population balance model a linear size dependent filtration function gave a good fit to the measured colloid concentration profile. The effects of constant versus size dependent filtration coefficients were compared and the differences illustrated by the calculated colloid profile within the column. Also observed from the model calculations was the dramatically changing liquid-phase colloid-size distribution which was plotted as a function of position down the column. This modeling approach was excellent for describing and understanding microscopic filtration in porous media

  6. Bacterial, viral and turbidity removal by intermittent slow sand filtration for household use in developing countries: experimental investigation and modeling.

    Science.gov (United States)

    Jenkins, Marion W; Tiwari, Sangam K; Darby, Jeannie

    2011-11-15

    A two-factor three-block experimental design was developed to permit rigorous evaluation and modeling of the main effects and interactions of sand size (d(10) of 0.17 and 0.52 mm) and hydraulic head (10, 20, and 30 cm) on removal of fecal coliform (FC) bacteria, MS2 bacteriophage virus, and turbidity, under two batch operating modes ('long' and 'short') in intermittent slow sand filters (ISSFs). Long operation involved an overnight pause time between feeding of two successive 20 L batches (16 h average batch residence time (RT)). Short operation involved no pause between two 20 L batch feeds (5h average batch RT). Conditions tested were representative of those encountered in developing country field settings. Over a ten week period, the 18 experimental filters were fed river water augmented with wastewater (influent turbidity of 5.4-58.6 NTU) and maintained with the wet harrowing method. Linear mixed modeling allowed systematic estimates of the independent marginal effects of each independent variable on each performance outcome of interest while controlling for the effects of variations in a batch's actual residence time, days since maintenance, and influent turbidity. This is the first study in which simultaneous measurement of bacteria, viruses and turbidity removal at the batch level over an extended duration has been undertaken with a large number of replicate units to permit rigorous modeling of ISSF performance variability within and across a range of likely filter design configurations and operating conditions. On average, the experimental filters removed 1.40 log fecal coliform CFU (SD 0.40 log, N=249), 0.54 log MS2 PFU (SD 0.42 log, N=245) and 89.0 percent turbidity (SD 6.9 percent, N=263). Effluent turbidity averaged 1.24 NTU (SD 0.53 NTU, N=263) and always remained below 3 NTU. Under the best performing design configuration and operating mode (fine sand, 10 cm head, long operation, initial HLR of 0.01-0.03 m/h), mean 1.82 log removal of bacteria (98

  7. [Music and Glaucoma].

    Science.gov (United States)

    Plange, N

    2017-02-01

    Music may have multiple influences on the human organism. A possible therapeutic effect for patients with glaucoma has been postulated, aside from the known impact of music on the cardiovascular system, psychogenic effects and a short-term improvement in mental performance (Mozart effect). The higher level of mental stress in patients with glaucoma and type-A personality behaviour may be related to higher intraocular pressure in patients with glaucoma. Relaxing music may have a positive impact in these patients, related to a reduction in intraocular pressure or its fluctuations. However, only limited data exist on the effects of music on intraocular pressure. No clinical studies have yet been performed to investigate the effect of music or music therapy on glaucoma progression. The music of Mozart may influence visual field examinations, possibly due to a positive short term effect on mental performance. This factor needs to be addressed in studies dealing with the effect of music in glaucoma. The relevance of intraocular pressure increases in professional wind instrument players is controversial. An increased level of care might be advisable in patients with advanced glaucoma. The influences of music on humans, altered personality profiles in patients with glaucoma and the studies showing some effect of stress on intraocular pressure stress the relevance of psychological support for glaucoma patients, who are confronted with a disease with a high longterm risk of blindness. Georg Thieme Verlag KG Stuttgart · New York.

  8. The Management of Secondary Glaucoma in Nanophthalmic Patients

    Institute of Scientific and Technical Information of China (English)

    Shengsong Huang; Minbin Yu; Changyu Qiu; Tiancai Ye

    2002-01-01

    Purpose: To investigate the clinical characteristcs, management of secondary glaucoma in nanophthalmos, and the prevention of its complications.Methods: Retrospectively, 9 cases (17 eyes) with nanophthalmic glaucoma were studied.Results: The axial length of the eyes ranged (14.36 ~ 19.33) mm; All of the cases combined with hyperopia ranged (+7.00~+16.00)D. All 17 eyes had the manifestation like angle-closure glaucoma.The glaucoma was controlled in 9 of 17 eyes at the early stage, which underwent laser iridotomy (4 of 9 eyes also underwent laser iridoplasty). 1 eye underwent ciliary photocoagulation because its visual acuity was lost and the patient complained of pain. The other 7 eyes underwent filtration surgery and 3 of them had permanent loss of vision caused by disastrous complications after the surgery.Conclusions: Management of secondary glaucoma in nanophthalmos is complicated. The laser iris surgery is safe and effective in glaucoma at the early stage. Vortex vein decompression, sclerotectomy or anterior sclerotomy may be performed to reduce disastrous complications.

  9. Ahmed glaucoma valve implant: surgical technique and complications.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  10. Nanotechnology Applications for Glaucoma.

    Science.gov (United States)

    Cetinel, Sibel; Montemagno, Carlo

    2016-01-01

    Glaucoma is the second leading cause of blindness worldwide, and the antiglaucoma treatments currently available suffer from various complications. Nanotechnology-based treatments show a great deal of promise in overcoming these complications and form the basis for next-generation glaucoma treatment strategies, with the help of applications such as controlled release, targeted delivery, increased bioavailability, diffusion limitations, and biocompatibility. Significant progress has been made in nanomedicine in the efficiency of antiglaucoma medications, nanofabrication systems such as microelectromechanical systems that remove the limitations of nanodevices, and tissue regeneration vesicles for developing glaucoma treatments not based on intraocular pressure. With the use of these advanced technologies, the prevention of glaucoma-induced blindness will be possible in the near future. Herein, we reviewed the recent advances in nanotechnology-based treatment strategies for glaucoma.

  11. Glaucoma: Screening Can Save Your Sight!

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Glaucoma: Screening Can Save Your Sight! Past Issues / Fall 2009 Table of Contents People with glaucoma see the world through a tunnel. Glaucoma is ...

  12. [Study of corvitin efficiency in primary glaucoma].

    Science.gov (United States)

    Mykheĭtseva, I M; Kashyntseva, L T; Artemov, O V; Khramenko, N I

    2012-01-01

    There were concluded our results of animal experimental investigation and clinical observation of the quercetin-containing preparation corvitin (C) in primary glaucoma treatment. On the model of disease it is shown for rabbit, that introduction of 0.5 ml 2 % C as factious instillation into the eye a basely decreased eye blood flow was increased twice, mionectic at glaucoma eye hydrodynamics was normalized : the outflow of liquid increased on 58 %, inflow - on 52 %, intraocular pressure went down on 14%. Intravenous inflowing of C brought down expressed of oxidative stress - M[see text]A in blood is decreased on 40 %, level of endothelial dysfunction marker NO is increased on 70 %. On the model of glaucoma for rats C, entered protractedly, showed the neuroprotective actions on the neurons of retina, promoting survivability of ganglion cells, that it is shown on histological preparations. Application C in the clinic of glaucoma (intravenously a 0.5 g of preparation in 100 ml of solution) improved for patients a blood supply in the eye on 25 %, and also rendered a positive antioxidant and metabolic effect. Noted positive influences of C concurrently to important pathogeneses factors such as regional eye blood supply, eye hydrodynamics, oxidative stress, metabolic changes, survival of retina neurons grounds to talk about new strategy of pathogenesis therapy of glaucoma.

  13. Cross-flow filtration and axial filtration

    International Nuclear Information System (INIS)

    Kraus, K.A.

    1974-01-01

    Two relatively novel alternative solid-liquid-separation techniques of filtration are discussed. In cross-flow filtration, the feed is pumped past the filtering surface. While in axial filtration the filter, mounted on a rotor, is moved with respect to the feed. While large-scale application of the axial filter is still in doubt, it permits with little expenditure of time and money, duplication of many hydrodynamic aspects of cross-flow filtration for fine-particle handling problems. The technique has been applied to municipal wastes, low-level radioactive waste treatment plant, lead removal from industrial wastes, removal of pulp-mill contaminants, textile-mill wastes, and pretreatment of saline waters by lime-soda process in preparation for hyperfiltration. Economics and energy requirements are also discussed

  14. Daily Life with Glaucoma

    Science.gov (United States)

    ... Size Small Text Medium Text Large Text Contrast Dark on Light Light on Dark Donate Search Menu Donate What is Glaucoma? Care ... Low Vision Resources Medication Guide Resources on the Web » See All Articles Where the Money Goes Have ...

  15. Glaucoma in developing countries

    Directory of Open Access Journals (Sweden)

    Ravi Thomas

    2012-01-01

    Full Text Available Objective: To describe the background and strategy required for the prevention of blindness from glaucoma in developing countries. Materials and Methods: Extrapolation of existing data and experience in eye care delivery and teaching models in an unequally developed country (India are used to make recommendations. Results: Parameters like population attributable risk percentage indicate that glaucoma is a public health problem but lack of simple diagnostic techniques and therapeutic interventions are barriers to any effective plan. Case detection rather than population-based screening is the recommended strategy for detection. Population awareness of the disease is low and most patients attending eye clinics do not receive a routine comprehensive eye examination that is required to detect glaucoma (and other potentially blinding eye diseases. Such a routine is not taught or practiced by the majority of training institutions either. Angle closure can be detected clinically and relatively simple interventions (including well performed cataract surgery can prevent blindness from this condition. The strategy for open angle glaucoma should focus on those with established functional loss. Outcomes of this proposed strategy are not yet available. Conclusions: Glaucoma cannot be managed in isolation. The objective should be to detect and manage all potential causes of blindness and prevention of blindness from glaucoma should be integrated into existing programs. The original pyramidal model of eye care delivery incorporates this principle and provides an initial starting point. The routine of comprehensive eye examination in every clinic and its teaching (and use in residency programs is mandatory for the detection and management of potentially preventable blinding pathology from any cause, including glaucoma. Programs for detection of glaucoma should not be initiated unless adequate facilities for diagnosis and surgical intervention are in place and

  16. Glaucoma after corneal replacement.

    Science.gov (United States)

    Baltaziak, Monika; Chew, Hall F; Podbielski, Dominik W; Ahmed, Iqbal Ike K

    Glaucoma is a well-known complication after corneal transplantation surgery. Traditional corneal transplantation surgery, specifically penetrating keratoplasty, has been slowly replaced by the advent of new corneal transplantation procedures: primarily lamellar keratoplasties. There has also been an emergence of keratoprosthesis implants for eyes that are high risk of failure with penetrating keratoplasty. Consequently, there are different rates of glaucoma, pathogenesis, and potential treatment in the form of medical, laser, or surgical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Clinical Metabolomics and Glaucoma.

    Science.gov (United States)

    Barbosa-Breda, João; Himmelreich, Uwe; Ghesquière, Bart; Rocha-Sousa, Amândio; Stalmans, Ingeborg

    2018-01-01

    Glaucoma is one of the leading causes of irreversible blindness worldwide. However, there are no biomarkers that accurately help clinicians perform an early diagnosis or detect patients with a high risk of progression. Metabolomics is the study of all metabolites in an organism, and it has the potential to provide a biomarker. This review summarizes the findings of metabolomics in glaucoma patients and explains why this field is promising for new research. We identified published studies that focused on metabolomics and ophthalmology. After providing an overview of metabolomics in ophthalmology, we focused on human glaucoma studies. Five studies have been conducted in glaucoma patients and all compared patients to healthy controls. Using mass spectrometry, significant differences were found in blood plasma in the metabolic pathways that involve palmitoylcarnitine, sphingolipids, vitamin D-related compounds, and steroid precursors. For nuclear magnetic resonance spectroscopy, a high glutamine-glutamate/creatine ratio was found in the vitreous and lateral geniculate body; no differences were detected in the optic radiations, and a lower N-acetylaspartate/choline ratio was observed in the geniculocalcarine and striate areas. Metabolomics can move glaucoma care towards a personalized approach and provide new knowledge concerning the pathophysiology of glaucoma, which can lead to new therapeutic options. © 2017 S. Karger AG, Basel.

  18. [OCT and neovascular glaucoma].

    Science.gov (United States)

    Bellotti, A; Labbé, A; Fayol, N; El Mahtoufi, A; Baudouin, C

    2007-06-01

    Neovascular glaucoma is a chronic and sight-threatening disease. Four different grades have been described. Anterior chamber optical coherence tomography (OCT) is a new imaging technique allowing the visualization of the anterior segment. The purpose of our study was to describe the appearance of the different neovascular glaucoma grades with the OCT in order to refine the clinical analysis of this disease. Eleven patients (nine men and two women) with different grades of neovascular glaucoma were analyzed in this study. Neovascular glaucoma complicated central retinal vein occlusion in seven patients and diabetic retinopathy in four patients. All patients had bilateral biomicroscopical examination and OCT analysis. OCT images and clinical examination were then compared. No modifications could be observed using OCT in patients with grade 1 neovascular glaucoma. For grade 2, a slightly hyper-reflective linear iris secondary to neovascularization was observed. For grade 3, OCT images showed a thickened hyper-reflective iridocorneal angle with possible iridocorneal synechiae. For grade 4, the iridocorneal angle was closed and associated with iris contraction and uveae ectropion. OCT is a new promising technique for the precise analysis of different grades of neovascular glaucoma. It certainly helps in the management of such cases.

  19. Experimental article – Reducing effective dose to a paediatric phantom by using different combinations of kVp, mAs and additional filtration whilst maintaining image quality

    NARCIS (Netherlands)

    Huizinga, Elsbeth; Schaake, Wouter; Visser, Ruurd; Bloomfield, Charlotte; Boavida, Filipa; Chabloz, Diane; Crausaz, Emilie; Hustveit, Hanne; Knight, Heidi; Pereira, Anna; Harsaker, Vanja

    2015-01-01

    Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and

  20. Experimental article – Reducing effective dose to a paediatric phantom by using different combinations of kVp, mAs and additional filtration whilst maintaining image quality

    NARCIS (Netherlands)

    Elsbeth Huizinga; Ana Pereira; Wouter Schaake; Charlotte Bloomfield; Heidi Knight; Emilie Crausaz; Hanne Hustveit; Ruurd Visser; Vanja Harsaker; Diane Chabloz; Filipa Boavida

    2015-01-01

    Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs

  1. A New Safety Concern for Glaucoma Treatment Demonstrated by Mass Spectrometry Imaging of Benzalkonium Chloride Distribution in the Eye, an Experimental Study in Rabbits

    Science.gov (United States)

    Brignole-Baudouin, Françoise; Desbenoit, Nicolas; Hamm, Gregory; Liang, Hong; Both, Jean-Pierre; Brunelle, Alain; Fournier, Isabelle; Guerineau, Vincent; Legouffe, Raphael; Stauber, Jonathan; Touboul, David; Wisztorski, Maxence; Salzet, Michel; Laprevote, Olivier; Baudouin, Christophe

    2012-01-01

    We investigated in a rabbit model, the eye distribution of topically instilled benzalkonium_(BAK) chloride a commonly used preservative in eye drops using mass spectrometry imaging. Three groups of three New Zealand rabbits each were used: a control one without instillation, one receiving 0.01%BAK twice a day for 5 months and one with 0.2%BAK one drop a day for 1 month. After sacrifice, eyes were embedded and frozen in tragacanth gum. Serial cryosections were alternately deposited on glass slides for histological (hematoxylin-eosin staining) and immunohistological controls (CD45, RLA-DR and vimentin for inflammatory cell infiltration as well as vimentin for Müller glial cell activation) and ITO or stainless steel plates for MSI experiments using Matrix-assisted laser desorption ionization time-of-flight. The MSI results were confirmed by a round-robin study on several adjacent sections conducted in two different laboratories using different sample preparation methods, mass spectrometers and data analysis softwares. BAK was shown to penetrate healthy eyes even after a short duration and was not only detected on the ocular surface structures, but also in deeper tissues, especially in sensitive areas involved in glaucoma pathophysiology, such as the trabecular meshwork and the optic nerve areas, as confirmed by images with histological stainings. CD45-, RLA-DR- and vimentin-positive cells increased in treated eyes. Vimentin was found only in the inner layer of retina in normal eyes and increased in all retinal layers in treated eyes, confirming an activation response to a cell stress. This ocular toxicological study confirms the presence of BAK preservative in ocular surface structures as well as in deeper structures involved in glaucoma disease. The inflammatory cell infiltration and Müller glial cell activation confirmed the deleterious effect of BAK. Although these results were obtained in animals, they highlight the importance of the safety-first principle for

  2. A new safety concern for glaucoma treatment demonstrated by mass spectrometry imaging of benzalkonium chloride distribution in the eye, an experimental study in rabbits.

    Science.gov (United States)

    Brignole-Baudouin, Françoise; Desbenoit, Nicolas; Hamm, Gregory; Liang, Hong; Both, Jean-Pierre; Brunelle, Alain; Fournier, Isabelle; Guerineau, Vincent; Legouffe, Raphael; Stauber, Jonathan; Touboul, David; Wisztorski, Maxence; Salzet, Michel; Laprevote, Olivier; Baudouin, Christophe

    2012-01-01

    We investigated in a rabbit model, the eye distribution of topically instilled benzalkonium_(BAK) chloride a commonly used preservative in eye drops using mass spectrometry imaging. Three groups of three New Zealand rabbits each were used: a control one without instillation, one receiving 0.01%BAK twice a day for 5 months and one with 0.2%BAK one drop a day for 1 month. After sacrifice, eyes were embedded and frozen in tragacanth gum. Serial cryosections were alternately deposited on glass slides for histological (hematoxylin-eosin staining) and immunohistological controls (CD45, RLA-DR and vimentin for inflammatory cell infiltration as well as vimentin for Müller glial cell activation) and ITO or stainless steel plates for MSI experiments using Matrix-assisted laser desorption ionization time-of-flight. The MSI results were confirmed by a round-robin study on several adjacent sections conducted in two different laboratories using different sample preparation methods, mass spectrometers and data analysis softwares. BAK was shown to penetrate healthy eyes even after a short duration and was not only detected on the ocular surface structures, but also in deeper tissues, especially in sensitive areas involved in glaucoma pathophysiology, such as the trabecular meshwork and the optic nerve areas, as confirmed by images with histological stainings. CD45-, RLA-DR- and vimentin-positive cells increased in treated eyes. Vimentin was found only in the inner layer of retina in normal eyes and increased in all retinal layers in treated eyes, confirming an activation response to a cell stress. This ocular toxicological study confirms the presence of BAK preservative in ocular surface structures as well as in deeper structures involved in glaucoma disease. The inflammatory cell infiltration and Müller glial cell activation confirmed the deleterious effect of BAK. Although these results were obtained in animals, they highlight the importance of the safety-first principle for

  3. A new safety concern for glaucoma treatment demonstrated by mass spectrometry imaging of benzalkonium chloride distribution in the eye, an experimental study in rabbits.

    Directory of Open Access Journals (Sweden)

    Françoise Brignole-Baudouin

    Full Text Available We investigated in a rabbit model, the eye distribution of topically instilled benzalkonium_(BAK chloride a commonly used preservative in eye drops using mass spectrometry imaging. Three groups of three New Zealand rabbits each were used: a control one without instillation, one receiving 0.01%BAK twice a day for 5 months and one with 0.2%BAK one drop a day for 1 month. After sacrifice, eyes were embedded and frozen in tragacanth gum. Serial cryosections were alternately deposited on glass slides for histological (hematoxylin-eosin staining and immunohistological controls (CD45, RLA-DR and vimentin for inflammatory cell infiltration as well as vimentin for Müller glial cell activation and ITO or stainless steel plates for MSI experiments using Matrix-assisted laser desorption ionization time-of-flight. The MSI results were confirmed by a round-robin study on several adjacent sections conducted in two different laboratories using different sample preparation methods, mass spectrometers and data analysis softwares. BAK was shown to penetrate healthy eyes even after a short duration and was not only detected on the ocular surface structures, but also in deeper tissues, especially in sensitive areas involved in glaucoma pathophysiology, such as the trabecular meshwork and the optic nerve areas, as confirmed by images with histological stainings. CD45-, RLA-DR- and vimentin-positive cells increased in treated eyes. Vimentin was found only in the inner layer of retina in normal eyes and increased in all retinal layers in treated eyes, confirming an activation response to a cell stress. This ocular toxicological study confirms the presence of BAK preservative in ocular surface structures as well as in deeper structures involved in glaucoma disease. The inflammatory cell infiltration and Müller glial cell activation confirmed the deleterious effect of BAK. Although these results were obtained in animals, they highlight the importance of the safety

  4. New Tool to Predict Glaucoma

    Science.gov (United States)

    ... In This Section A New Tool to Predict Glaucoma email Send this article to a friend by ... Close Send Thanks for emailing that article! Tweet Glaucoma can be difficult to detect and diagnose. Measurement ...

  5. Does Your Child Have Glaucoma?

    Science.gov (United States)

    ... Donate In This Section Does Your Child Have Glaucoma? email Send this article to a friend by ... a pediatric ophthalmologist. Signs and Symptoms of Childhood Glaucoma What to watch for in children under the ...

  6. Does Marijuana Help Treat Glaucoma?

    Science.gov (United States)

    ... time, reducing side vision. It sometimes leads to blindness. One cause of optic nerve damage in glaucoma ... high doses, can cause problems with short-term memory and concentration. As scientists learn more about glaucoma, ...

  7. Dynamic Heterogeneous Multiscale Filtration Model: Probing Micro- and Macroscopic Filtration Characteristics of Gasoline Particulate Filters.

    Science.gov (United States)

    Gong, Jian; Viswanathan, Sandeep; Rothamer, David A; Foster, David E; Rutland, Christopher J

    2017-10-03

    Motivated by high filtration efficiency (mass- and number-based) and low pressure drop requirements for gasoline particulate filters (GPFs), a previously developed heterogeneous multiscale filtration (HMF) model is extended to simulate dynamic filtration characteristics of GPFs. This dynamic HMF model is based on a probability density function (PDF) description of the pore size distribution and classical filtration theory. The microstructure of the porous substrate in a GPF is resolved and included in the model. Fundamental particulate filtration experiments were conducted using an exhaust filtration analysis (EFA) system for model validation. The particulate in the filtration experiments was sampled from a spark-ignition direct-injection (SIDI) gasoline engine. With the dynamic HMF model, evolution of the microscopic characteristics of the substrate (pore size distribution, porosity, permeability, and deposited particulate inside the porous substrate) during filtration can be probed. Also, predicted macroscopic filtration characteristics including particle number concentration and normalized pressure drop show good agreement with the experimental data. The resulting dynamic HMF model can be used to study the dynamic particulate filtration process in GPFs with distinct microstructures, serving as a powerful tool for GPF design and optimization.

  8. [Uveitic Secondary Glaucoma].

    Science.gov (United States)

    Lommatzsch, Claudia; Heinz, Carsten

    2018-05-01

    An intraocular pressure increase with development of glaucomatous damage is a common complication of uveitis. The prevalence has a wide range depending on various factors such as the underlying uveitis type and the duration of the disease. Pathogenetically, a distinction must be made between a secondary angle closure component and the more frequently occurring open-angle glaucoma. In diagnostics, in addition to the clinical optic nerve head assessment, perimetry and tonometry, the use of imaging examination equipment, such as OCT and HRT, are recommended. In the context of uveitic glaucoma, it must be considered in the evaluation, because the glaucoma-typical changes are generally less pronounced or can be concealed by retinal swelling in comparison with other forms of glaucoma. Therapeutically, drug therapy in the form of eye drops continues to be a first-line recommendation, with the use of topical carbonic anhydrase inhibitors or beta-blockers primarily preferred, depending on the contraindications. An operative therapy follows after unsuccessful or inadequate conservative therapy: the adequate surgical technique depends on the respective finding and includes actually techniques such as filtering procedures and glaucoma drainage devices. Georg Thieme Verlag KG Stuttgart · New York.

  9. Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma

    Science.gov (United States)

    Shen, Christopher C; Salim, Sarwat; Du, Haiming; Netland, Peter A

    2011-01-01

    Purpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 eyes of 39 patients with underlying diagnosis of neovascular glaucoma, divided into two groups: Ahmed Glaucoma Valve (N = 20) and trabeculectomy with mitomycin C (N = 20). Surgical success was defined as 6 mm Hg ≤ intraocular pressure ≤21 mm Hg, with or without the use of glaucoma medications, with no further glaucoma surgery, and light perception or better vision. Early postoperative hypotony was defined as intraocular pressure Ahmed Glaucoma Valve group and 25 months (6–77 months) for the trabeculectomy group. Although the mean number of postoperative intraocular pressure-lowering medications was significantly higher in the trabeculectomy group compared with the Ahmed Glaucoma Valve group at 3 and 6 month time points, there was no statistically significant difference at any other time point. There was no statistically significant difference between both groups in postoperative visual acuity and intraocular pressure. Success was 70% and 65% at 1 year and 60% and 55% at 2 years after Ahmed Glaucoma Valve and trabeculectomy, respectively. Kaplan–Meier survival curve analysis showed no significant difference in success between the two groups (P = 0.815). Hyphema was the most common complication in both groups. Conclusion: We found similar results after trabeculectomy with mitomycin C and Ahmed Glaucoma Valve implantation in eyes with neovascular glaucoma. PMID:21468334

  10. Glaucoma treatment trends: a review.

    Science.gov (United States)

    Conlon, Ronan; Saheb, Hady; Ahmed, Iqbal Ike K

    2017-02-01

    Glaucoma is one of the most common causes of blindness worldwide, and its prevalence is increasing. The aim of the present review is to describe the current medical and surgical treatment trends in the management of open-angle glaucoma. There has been an increase in the availability of glaucoma medications and the use of laser trabeculoplasty over the past decade, with a subsequent decrease in invasive incisional surgery. In addition, a new class of glaucoma procedures, termed microinvasive glaucoma surgery, has emerged, which aims to fill the gap between conservative medical management and more invasive surgery. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  11. Glaucoma: Hot Topics in Pharmacology.

    Science.gov (United States)

    Balendra, Shiama I; Shah, Parth Arvind; Jain, Mishank; Grzybowski, Andrzej; Cordeiro, Maria F

    2017-01-01

    Glaucoma comprises a group of neurodegenerative diseases resulting in retinal ganglion cell death within the optic nerve head. It is projected to affect almost 80 million people worldwide by 2020. The condition's asymptomatic nature translates to over half of glaucoma sufferers being unaware of their condition. By the time of diagnosis, irreversible blindness is likely to have occurred. Prime areas of glaucoma research therefore include identification and optimization of risk factors for the disease, accurate and early diagnostic tools and novel therapeutic methods. The goal of this review was to summarize main areas of latest glaucoma research into risk factors of glaucoma, diagnostic tools and treatments. PubMed was used to search for terms including glaucoma risk factors, glaucoma diagnostics, glaucoma treatment, glaucoma drug delivery and glaucoma IOP. The evidence for risk factors of low CSF pressure, IOP, smoking, vascular risk factors and light toxicity is described. Latest diagnostic and monitoring techniques for glaucoma include SD-OCT, DARC and IOP telemetry. Current and emerging medical and surgical treatments in glaucoma are discussed. Rho kinase inhibitors have the potential to both lower IOP and also provide neuroprotection, several of which are in clinical trials. Several other new medical treatments such as calcium channel blockers and neurotrophic agents also have the capacity to provide neuroprotection. Minimally Invasive Glaucoma Surgery (MIGS) devices provide an improved safety profile compared to traditional trabeculectomy; the latest ab interno and ab externo devices are described. Novel drug delivery methods, including punctual plugs and contact lenses, help overcome the challenges with patient adherence. The ultimate goals are to reduce the individual patient risk factors associated with glaucoma, diagnose the condition early and to find treatments that not only reduce IOP but also reverse neurodegeneration of RGCs. The usage of combinations

  12. Glaucoma Monitoring in a Clinical Setting Glaucoma Progression Analysis vs Nonparametric Progression Analysis in the Groningen Longitudinal Glaucoma Study

    NARCIS (Netherlands)

    Wesselink, Christiaan; Heeg, Govert P.; Jansonius, Nomdo M.

    Objective: To compare prospectively 2 perimetric progression detection algorithms for glaucoma, the Early Manifest Glaucoma Trial algorithm (glaucoma progression analysis [GPA]) and a nonparametric algorithm applied to the mean deviation (MD) (nonparametric progression analysis [NPA]). Methods:

  13. Challenges in Glaucoma Management

    African Journals Online (AJOL)

    James Standefer

    Glaucoma has been referred to as the 'orphan child' of Vision. 2020 because, though it is the world's leading cause of irreversible blindness, it was not included in its initial list. The main reasons include the inability to restore lost vision, and the need for upgrading the substandard clinical skill levels of many developing ...

  14. Classic papers in glaucoma

    National Research Council Canada - National Science Library

    Ritch, Robert; Caronia, Ronald M

    1999-01-01

    ... Elimination of Intraocular Fluid J.S. Friedenwald The Formation of the Intraocular Fluid. Proctor Award Lecture of the Association for Research in Ophthalmology W.M. Grant, Tonographic Method for Measuring the Facility and Rate of Aqueous Flow in Human Eyes P.A. Chandler , Malignant Glaucoma B. Becker, Decrease in Intraocular Pressure in Man by a Carbo...

  15. Pesquisaje de glaucoma

    Directory of Open Access Journals (Sweden)

    Aldo Sigler Villanueva

    1996-06-01

    Full Text Available Se efectuó un pesquisaje de glaucoma mediante un chequeo masivo al 92,1 % (210 pacientes de la población mayor de 40 años de edad atendida en un consultorio del médico de la familia del municipio Morón. Se encontró que el 9,6 % (20 pacientes presentaban cifras de tensión ocular por encima de los valores normales, así como 3 pacientes que tenían tensión ocular normal, pero con excavaciones de papilas sospechosas y 2 pacientes con antecedentes familiares de glaucoma, los cuales se enviaron a la consulta especializada del Hospital General Provincial Docente de Moron para confirmar o no el diagnóstico.The 92,1 % (210 patients of the population over 40 years treated at a family physician's office in Morón municipality took part in a glaucoma mass screening. It was found that 9,6 % (20 patients showed figures of ocular tension exceeding normal values and that 3 patients had normal ocular tension but presented suspicious excavation of the optic disc. Two patients having glaucoma family history were referred to the specialist at the Provincial General Teaching Hospital of Moron in order to confirm the diagnosis.

  16. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  17. Glaucomas in Africas

    African Journals Online (AJOL)

    Murdoch

    happens in all secondary glaucomas. There was confusion some years ago in our understanding of the disease, since intraocular pressure was included in the definition of the disease. With the advent of population studies it became apparent that, in some populations, a significant proportion of those with the characteristic ...

  18. Genetics Home Reference: early-onset glaucoma

    Science.gov (United States)

    ... called a syndrome. If glaucoma appears before the age of 5 without other associated abnormalities, it is called primary congenital glaucoma. Other individuals experience early onset of primary open-angle glaucoma, the most ...

  19. Glaucoma: Symptoms, Diagnosis, Treatment and Latest Research

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Glaucoma: Symptoms, Diagnosis, Treatment and Latest Research Past Issues / Fall 2009 Table of Contents Symptoms and Diagnosis Glaucoma can develop in one or both eyes. Often ...

  20. Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma

    OpenAIRE

    Netland, Peter; Shen,Chris; Salim,Sarwat; Du,Haiming

    2011-01-01

    Christopher C Shen1, Sarwat Salim2, Haiming Du2, Peter A Netland31Glaucoma Consultants Northwest, Seattle, WA, USA; 2University of Tennessee Health Science Center, Memphis, TN, USA; 3University of Virginia School of Medicine, Charlottesville, VA, USAPurpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 e...

  1. PROBLEMS OF NONSTATIONARY FILTRATION

    Directory of Open Access Journals (Sweden)

    Vsevolod A. Shabanov

    2018-03-01

    Full Text Available he article deals with the classical hydrodynamic theory of filtration. Discusses models of soil, fluid and nature of fluid flow that formed the basis for the creation of the classic filtration theory. Also discusses the assumptions made for the linearization of the equations. Evaluated the scope of the classical filtration theory. Proposed a new model of filtration through a porous medium, based on the application of the laws of theoretical mechanics. It is based on the classical model of soil: the soil is composed of capillaries with ..parallel axes, in which the liquid moves. For tasks of infiltration equations of motion. Considered special cases of unsteady motion of a finite volume of liquid. Numerical example a machine experiment.

  2. Water Filtration through Homogeneous Granulated Charge

    Directory of Open Access Journals (Sweden)

    A. M. Krautsou

    2005-01-01

    Full Text Available General relationship for calculation of water filtration through homogeneous granulated charge has been obtained. The obtained relationship has been compared with experimental data. Discrepancies between calculated and experimental values do not exceed 6 % throughout the entire investigated range.

  3. Lasers in primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Sihota Ramanjit

    2011-12-01

    Full Text Available Lasers have been used in the treatment of primary open angle glaucoma (POAG over the years, with the hope that they would eventually replace medical and surgical therapy. Laser trabeculoplasty (LT is an application of argon, diode, or selective laser energy to the surface of the trabecular meshwork to increase the aqueous outflow. The mechanisms by which intraocular pressure (IOP is lowered could be mechanical, biologic, or by division of adjacent cells. It is commonly used as an adjunct to medical therapy, but is contraindicated if the angle is obstructed, e.g., peripheral anterior synechia (PAS or developmental glaucomas. About 75% of individuals will show a significant fall in IOP after argon laser trabeculoplasty (ALT, and the response is similar with selective laser trabeculoplasty (SLT. The effects of LT are not always long lasting, with about 10% of individuals showing a rise in IOP with every passing year. Laser thermal sclerostomy, ab interno or externo, is an alternative to other full-thickness filtration procedures. Longer wavelengths in the infrared range have water-absorptive characteristics that facilitate perforation of the sclera. These lasers can be used to avoid intraocular instrumentation and minimize conjunctival trauma.

  4. Study of surgical treatment on neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Nü Liu

    2014-05-01

    Full Text Available AIM: To compare the effect of two surgical methods on neovascular glaucoma(NVG. METHODS: The clinical date of 46 cases(57 eyeswith NVG underwent surgical treatment were retrospectively analyzed and followed-up. Patients were divided into Ahmed glaucoma valve(AGVimplantation group(group A, 24 cases, 31 eyesand semiconductor diode laser transscleral ciliary body photocoagulation(TSCPCgroup(group B, 22cases, 26 eyesaccording to the surgical approach. The intraocular pressure, visual acuity and postoperative complications were compared before and after operation. RESULTS: The intraocular pressure postoperative in two groups were significantly lower than those preoperative(P P>0.05. The changes of visual acuity postoperative showed no statistical difference between the two groups(P>0.05. The postoperative complications of group A was significantly lower than that in group B, in which the incidence of eye pain, anterior chamber bleeding were significant differences between two groups(P CONCLUSION: AGV implantation treatment and TSCPC for NVG are both valid, but AGV implantation is filtration surgery, and TSCPC isciliary body destructive surgery, and the latter has higher rate of postoperative complications.

  5. Water Filtration Products

    Science.gov (United States)

    1986-01-01

    American Water Corporation manufactures water filtration products which incorporate technology originally developed for manned space operations. The formula involves granular activated charcoal and other ingredients, and removes substances by catalytic reactions, mechanical filtration, and absorption. Details are proprietary. A NASA literature search contributed to development of the compound. The technology is being extended to a deodorizing compound called Biofresh which traps gas and moisture inside the unit. Further applications are anticipated.

  6. Minimally invasive glaucoma surgery: current status and future prospects

    Directory of Open Access Journals (Sweden)

    Richter GM

    2016-01-01

    Full Text Available Grace M Richter,1,2 Anne L Coleman11UCLA Stein Eye Institute, Department of Ophthalmology, University of California, Los Angeles, CA, USA; 2USC Eye Institute, Department of Ophthalmology, Keck School of Medicine of University of Southern California, Los Angeles, CA, USAAbstract: Minimally invasive glaucoma surgery aims to provide a medication-sparing, conjunctival-sparing, ab interno approach to intraocular pressure reduction for patients with mild-to-moderate glaucoma that is safer than traditional incisional glaucoma surgery. The current approaches include: increasing trabecular outflow (Trabectome, iStent, Hydrus stent, gonioscopy-assisted transluminal trabeculotomy, excimer laser trabeculotomy; suprachoroidal shunts (Cypass micro-stent; reducing aqueous production (endocyclophotocoagulation; and subconjunctival filtration (XEN gel stent. The data on each surgical procedure for each of these approaches are reviewed in this article, patient selection pearls learned to date are discussed, and expectations for the future are examined. Keywords: MIGS, microincisional glaucoma surgery, trabecular stent, Schlemm’s canal, suprachoroidal shunt, ab interno

  7. Glaucoma in patients with uveitis.

    OpenAIRE

    Panek, W C; Holland, G N; Lee, D A; Christensen, R E

    1990-01-01

    The records of 100 patients (161 eyes) with uveitis were reviewed retrospectively to determine the prevalence of increased intraocular pressure, the forms of uveitis most commonly associated with glaucoma, and the forms that require specific glaucoma therapy. Secondary glaucoma was present in 23 patients (31 eyes): three of 24 patients with acute uveitis (three eyes, 12% of acute uveitis patients) and 20 of 76 patients with chronic uveitis (28 eyes, 26% of chronic uveitis patients). Eighteen ...

  8. Economic impact of primary open-angle glaucoma in Australia.

    Science.gov (United States)

    Dirani, Mohamed; Crowston, Jonathan G; Taylor, Penny S; Moore, Peter T; Rogers, Sophie; Pezzullo, M Lynne; Keeffe, Jill E; Taylor, Hugh R

    2011-01-01

    Glaucoma is the World's leading cause of irreversible blindness, and poses serious public health and economic concerns.   Review. Published randomized trials and population-based studies since 1985. We report the economic impact of primary open-angle glaucoma and model the effect of changes in detection rates and management strategies. The cost-effectiveness of different interventions to prevent vision loss from primary open-angle glaucoma was measured in terms of financial cost (Australian dollars) and disability-adjusted life years. The prevalence of glaucoma in Australia is expected to increase from 208 000 in 2005 to 379 000 in 2025 because of the aging population. Health system costs over the same time period are estimated to increase from $AU355 million to $AU784 million. Total costs (health system costs, indirect costs and costs of loss of well-being) will increase from $AU1.9 billion to $AU4.3 billion in Australia. Primary open-angle glaucoma poses a significant economic burden, which will increase substantially by 2025. This dynamic model provides a valuable tool for ongoing policy formulation and determining the economic impact of interventions to better prevent visual impairment and blindness from glaucoma. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  9. Cambridge community Optometry Glaucoma Scheme.

    Science.gov (United States)

    Keenan, Jonathan; Shahid, Humma; Bourne, Rupert R; White, Andrew J; Martin, Keith R

    2015-04-01

    With a higher life expectancy, there is an increased demand for hospital glaucoma services in the United Kingdom. The Cambridge community Optometry Glaucoma Scheme (COGS) was initiated in 2010, where new referrals for suspected glaucoma are evaluated by community optometrists with a special interest in glaucoma, with virtual electronic review and validation by a consultant ophthalmologist with special interest in glaucoma. 1733 patients were evaluated by this scheme between 2010 and 2013. Clinical assessment is performed by the optometrist at a remote site. Goldmann applanation tonometry, pachymetry, monoscopic colour optic disc photographs and automated Humphrey visual field testing are performed. A clinical decision is made as to whether a patient has glaucoma or is a suspect, and referred on or discharged as a false positive referral. The clinical findings, optic disc photographs and visual field test results are transmitted electronically for virtual review by a consultant ophthalmologist. The number of false positive referrals from initial referral into the scheme. Of the patients, 46.6% were discharged at assessment and a further 5.7% were discharged following virtual review. Of the patients initially discharged, 2.8% were recalled following virtual review. Following assessment at the hospital, a further 10.5% were discharged after a single visit. The COGS community-based glaucoma screening programme is a safe and effective way of evaluating glaucoma referrals in the community and reducing false-positive referrals for glaucoma into the hospital system. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  10. Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma.

    Science.gov (United States)

    Pakravan, Mohammad; Esfandiari, Hamed; Yazdani, Shahin; Doozandeh, Azadeh; Dastborhan, Zahra; Gerami, Ebrahim; Kheiri, Bahareh; Pakravan, Parastou; Yaseri, Mehdi; Hassanpour, Kiana

    2018-03-01

    To evaluate the outcomes of Ahmed glaucoma valve implantation in refractory primary congenital glaucoma as well as primary procedure in aphakic glaucoma. In this retrospective study, medical records of patients who underwent Ahmed glaucoma valve implantation for refractory glaucoma and aphakic glaucoma were reviewed. Primary outcome measures were the surgical success defined as intraocular pressure ≤21 mm Hg and decreased ≥20% and no secondary glaucoma surgery. Secondary outcome measures were the number of glaucoma medications, complications, best corrected visual acuity, and intraocular pressure. A total of 62 eyes of refractory primary congenital glaucoma patients (group 1) and 33 eyes of aphakic glaucoma patients (group 2) were included in our study. Mean follow-up was 51 ± 33 months in group 1 and 49 ± 41 months in group 2 (p = 0.82). The cumulative probability of success was 90% in both groups at the first year; however, the success rate was 52.5% in group 1 and 71.5% in group 2 at 5 years' follow-up visit. In group 1, the mean intraocular pressure ± standard deviation was 33.1 ± 8.6 mm Hg at the baseline and decreased to 17.1 ± 5.3 mm Hg at 1 year and 18.5 ± 6.4 at 3 years postoperatively (all p's glaucoma medications was 3 ± 0.7 that decreased to 2 ± 0.8 at final follow-up (p = 0.02). Ahmed glaucoma valve implantation has a moderate success rate in the management of refractory primary congenital glaucoma with an increased chance of tube-related complications. The surgical success rate is higher in case of primary Ahmed glaucoma valve implant for aphakic glaucoma with acceptable safety profile.

  11. Building a glaucoma interaction network using a text mining approach.

    Science.gov (United States)

    Soliman, Maha; Nasraoui, Olfa; Cooper, Nigel G F

    2016-01-01

    The volume of biomedical literature and its underlying knowledge base is rapidly expanding, making it beyond the ability of a single human being to read through all the literature. Several automated methods have been developed to help make sense of this dilemma. The present study reports on the results of a text mining approach to extract gene interactions from the data warehouse of published experimental results which are then used to benchmark an interaction network associated with glaucoma. To the best of our knowledge, there is, as yet, no glaucoma interaction network derived solely from text mining approaches. The presence of such a network could provide a useful summative knowledge base to complement other forms of clinical information related to this disease. A glaucoma corpus was constructed from PubMed Central and a text mining approach was applied to extract genes and their relations from this corpus. The extracted relations between genes were checked using reference interaction databases and classified generally as known or new relations. The extracted genes and relations were then used to construct a glaucoma interaction network. Analysis of the resulting network indicated that it bears the characteristics of a small world interaction network. Our analysis showed the presence of seven glaucoma linked genes that defined the network modularity. A web-based system for browsing and visualizing the extracted glaucoma related interaction networks is made available at http://neurogene.spd.louisville.edu/GlaucomaINViewer/Form1.aspx. This study has reported the first version of a glaucoma interaction network using a text mining approach. The power of such an approach is in its ability to cover a wide range of glaucoma related studies published over many years. Hence, a bigger picture of the disease can be established. To the best of our knowledge, this is the first glaucoma interaction network to summarize the known literature. The major findings were a set of

  12. Neuroprotective therapies for glaucoma

    Directory of Open Access Journals (Sweden)

    Song W

    2015-03-01

    Full Text Available Wei Song, Ping Huang, Chun Zhang Department of Ophthalmology, Peking University Third Hospital, Beijing, People’s Republic of China Abstract: Glaucoma is the second leading cause for blindness worldwide. It is mainly caused by glaucomatous optic neuropathy (GON characterized by retinal ganglion cell loss, which leads to visual field defect and blindness. Up to now, the main purpose of antiglaucomatous therapies has been to lower intraocular pressure (IOP through surgeries and medications. However, it has been found that progressive GON is still present in some patients with effective IOP decrease. Therefore, risk factors other than IOP elevation, like neurotrophin deprivation and excitotoxicity, contribute to progressive GON. Novel approaches of neuroprotection may be more effective for preserving the function of the optic nerve. Keywords: glaucoma, glaucomatous optic neuropathy, retinal ganglion cells, neuro­protection

  13. Ceratoplastia penetrante e glaucoma Penetrating keratoplasty and glaucoma

    Directory of Open Access Journals (Sweden)

    Márcio Eulálio Barreto Soares

    2007-08-01

    Full Text Available O objetivo deste artigo é discutir os conhecimentos atuais sobre a abordagem clínica e terapêutica da ceratoplastia penetrante e do glaucoma a ela associado.The aim of this article is to make a review about glaucoma associated with penetrating keratoplasty, describing since its incidence and risk factors until the different options for treatment.

  14. Glaucoma Medication Preferences among Glaucoma Specialists in Mexico.

    Science.gov (United States)

    Lazcano-Gomez, Gabriel; Alvarez-Ascencio, Daniela; Haro-Zuno, Cindy; Turati-Acosta, Mauricio; Garcia-Huerta, Magdalena; Jimenez-Arroyo, Jesus; Castañeda-Diez, Rafael; Castillejos-Chevez, Armando; Gonzalez-Salinas, Roberto; Dominguez-Dueñas, Francisca; Jimenez-Roman, Jesus

    2017-01-01

    To determine the glaucoma specialists' preferences for the different brands of topical glaucoma medications available in Mexico. A web-based survey was sent to 150 board-certified glaucoma specialists in Mexico, with 14 questions related to brand preferences for all glaucoma medications available in Mexico. Participants were asked to select each glaucoma medication class by brand and to state the factors leading to their choice. Data from 111 (74%) glaucoma specialists were collected. Imot (timolol 0.5%; Sophia, Mexico) was the preferred brand for the beta-blockers (BB) class by 71% (n = 79) of the participants. Azopt (brinzolamide 1%; Alcon Lab, US) was the preferred carbonic anhydrase inhibitor (CAI) by 54% (n = 60) of the glaucoma specialists. Lumigan (bimatoprost 0.01% and 0.03%; Allergan Inc., U.S.) was the first choice for the prostaglandin analogues (PGAs) in 62% (n = 70) of the answers. The most frequently prescribed alpha-agonist (AA) was Agglad (brimonidine 0.2%; Sophia Lab, Mexico) in 44% (n = 49) of the answers. Medication accessibility (31%), cost (29%), and recommended dose (23%) were the three main factors influencing the glaucoma specialists' preferences. Medication cost and accessibility, as well as posology, remain the main factors influencing brand preferences among glaucoma doctors. In our professional opinion, the therapeutic effect must be the leading factor when prescribing topical medications in the daily practice, so that patients receive the best treatment option. This survey provides an understanding of the decision-making process when prescribing glaucoma medications by glaucoma specialists in a Latin American developing country. Ideally, patient treatment should be individualized and aimed to achieve the best results possible for their specific condition. How to cite this article: Lazcano-Gomez G, Alvarez-Ascencio D, Haro-Zuno C, Turati-Acosta M, Garcia-Huerta M, Jimenez-Arroyo J, Castañeda-Diez R, Castillejos-Chevez A, Gonzalez

  15. Noninvasive experimental determination of the individual kidney filtration fraction by means of a dual-tracer technique. [/sup 131/I and /sup 99m/Tc tracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Assailly, J.; Pavel, D.G.; Bader, C.; Chanard, J.; Ryerson, T.W.; Cotard, J.P.; Funck-Brentano, J.L.

    1977-07-01

    A noninvasive method for measurement of the individual kidney filtration fraction (FF) is presented, based on an analysis of the early rise of the kidneys' time-activity curves obtained after simultaneous injection of tubular (/sup 131/I) ortho-iodohippurate and glomerular (Tc-99m DTPA) tracers. The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. The dual-tracer technique allows the direct calculation of the ratio of glomerular to tubular clearances, i.e., the FF. In vivo studies were performed on 12 dogs, including normals as well as others with acute ureteral ligation or Benemid-induced tubular blockade. The calculated FF correlated well with the FF obtained from single-shot clearances performed simultaneously. We conclude that the FF can be calculated directly for each kidney, noninvasively, from the early part of the tubular and glomerular time-activity curves by noninvasive external detection.

  16. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Depaoli, D.

    1996-01-01

    This task will investigate the capabilities of magnetic-seeding filtration for the enhanced removal of magnetic and nonmagnetic particulates from liquids. This technology appies to a wide range of liquid wastes, including groundwater, process waters, and tank supernatant. Magnetic-seeding filtration can be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal-size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes

  17. Glaucoma: a brief update for 2017

    African Journals Online (AJOL)

    glaucoma. Predictions are that glaucoma will affect almost ... Abstract. Glaucoma is a complex condition of the eye and the second leading cause of blindness around the globe. ..... a stinging sensation upon instilling the drops into the eyes, as well as dry eyes .... Dimitriou C, Broadway D. Pathophysiology of glaucoma.

  18. Arguments Against Funding Glaucoma Treatment and Rebuttal

    African Journals Online (AJOL)

    2018-03-01

    Mar 1, 2018 ... for the treatment of glaucoma at no cost to IWG at the point of delivery toward reducing glaucoma,s harmful impact on the .... and logistic reasons. Nigeria doesn .... cataract unlike from glaucoma can be reversed. This does not.

  19. Experience with the Ahmed Glaucoma Valve

    African Journals Online (AJOL)

    Design:Aprospective study of three glaucoma patients who had the Ahmed glaucoma valve implant at the. University of Benin ... Key words: glaucoma, glaucoma valve implant, ... introduced the micro-trephination with a diameter of. 0.6mm in ...

  20. Changes of enzyme activities in lens after glaucoma trabecular resection

    Directory of Open Access Journals (Sweden)

    Jian-Ping Wang

    2013-08-01

    Full Text Available AIM: To observe the change of lens antioxidant enzyme activity after glaucoma trabecular resection. METHODS: Thirty-two eyes of sixteen New-Zealand rabbits(2.2-2.4kgwere divided into two groups. The left eyes of rabbits underwent standard glaucoma trabecular resection were treatment group, and the normal right eyes served as controls. Transparency of lenses was monitored by a slit-lamp biomicroscopy before and after glaucoma trabecular resection. The morphology of lens cells was observed under the light microscope.The activities of Na+-K+-ATPase,catalase(CAT, glutathion peroxidase(GSH-px, glutathione reductase(GR, superoxide dismutase(SODand content of malondialdehyde(MDAin lenses were detected six months after trabecular resection. RESULTS: Lenses were clear in both treatment group and normal control group during the six months after operation. The morphology and structure of lens cells were normal under the light microscope in both operation group and normal group. The activity of lens cells antioxidant enzyme activity were significantly decreased in operation group compared with control group, Na+-K+-ATPase declined by 20.97%, CAT declined by 16.36%, SOD declined by 4.46%, GR declined by 4.85%, GSH-px declined by 10.02%, and MDA increased by 16.31%. CONCLUSION: Glaucoma trabecular resection can induce the change of Na+-K+-ATPase, CAT, GSH-px, GR, SOD and MDA in lens of rabbit. Glaucoma filtration surgery for the occurrence of cataract development mechanism has important guiding significance.

  1. Water Treatment Technology - Filtration.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on filtration provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purposes of sedimentation basins and flocculation…

  2. Watch Out for Glaucoma | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Watch Out for Glaucoma Past Issues / Spring 2015 Table of Contents A ... used to check eye pressure for signs of glaucoma. Photo courtesy of NEI Glaucoma is a group ...

  3. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  4. Aqueous shunts for glaucoma.

    Science.gov (United States)

    Tseng, Victoria L; Coleman, Anne L; Chang, Melinda Y; Caprioli, Joseph

    2017-07-28

    Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. We included 27 trials with a total of 2099 participants with mixed diagnoses and comparisons of interventions. Seventeen studies reported adequate methods of randomization, and seven reported adequate allocation concealment. Data collection and follow-up times varied.Four trials compared an aqueous shunt (Ahmed or Baerveldt) with trabeculectomy, of which

  5. Evaluation of a glaucoma patient

    Science.gov (United States)

    Thomas, Ravi; Loibl, Klaus; Parikh, Rajul

    2011-01-01

    The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma. PMID:21150033

  6. Evaluation of a glaucoma patient

    Directory of Open Access Journals (Sweden)

    Thomas Ravi

    2011-12-01

    Full Text Available The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma.

  7. Acupuncture for glaucoma.

    Science.gov (United States)

    Law, Simon K; Li, Tianjing

    2013-05-31

    Glaucoma is a multifactorial optic neuropathy characterized by an acquired loss of retinal ganglion cells at levels beyond normal age-related loss and corresponding atrophy of the optic nerve. Although many treatments are available to manage glaucoma, glaucoma is a chronic condition. Some patients may seek complementary or alternative medicine approaches such as acupuncture to supplement their regular treatment. The underlying plausibility of acupuncture is that disorders related to the flow of Chi (the traditional Chinese concept translated as vital force or energy) can be prevented or treated by stimulating relevant points on the body surface. The objective of this review was to assess the effectiveness and safety of acupuncture in people with glaucoma. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to January 2013), EMBASE (January 1980 to January 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2013), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to January 2013), ZETOC (January 1993 to January 2013), Allied and Complementary Medicine Database (AMED) (January 1985 to January 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov), the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the National Center for Complementary and Alternative Medicine web site (NCCAM) (http://nccam.nih.gov). We did not use any language or date restrictions in the search for trials. We last searched the electronic databases on 8 January 2013 with the exception of NCCAM which was last searched on 14 July 2010. We also handsearched Chinese

  8. Method of electrostatic filtration

    International Nuclear Information System (INIS)

    Devienne, F.M.

    1975-01-01

    Electrostatic filtration of secondary ions of mass m in a given mass ratio with a primary ion of mass M which has formed the secondary ions by fission is carried out by a method which consists in forming a singly-charged primary ion of the substance having a molecular mass M and extracting the ion at a voltage V 1 with respect to ground. The primary ion crosses a potential barrier V 2 , in producing the dissociation of the ion into at least two fragments of secondary ions and in extracting the fragment ion of mass m at a voltage V 2 . Filtration is carried out in an electrostatic analyzer through which only the ions of energy eV'' are permitted to pass, detecting the ions which have been filtered. The mass m of the ions is such that (M/m) = (V 1 - V 2 )/(V'' - V 2 )

  9. The molecular basis of retinal ganglion cell death in glaucoma.

    Science.gov (United States)

    Almasieh, Mohammadali; Wilson, Ariel M; Morquette, Barbara; Cueva Vargas, Jorge Luis; Di Polo, Adriana

    2012-03-01

    Glaucoma is a group of diseases characterized by progressive optic nerve degeneration that results in visual field loss and irreversible blindness. A crucial element in the pathophysiology of all forms of glaucoma is the death of retinal ganglion cells (RGCs), a population of CNS neurons with their soma in the inner retina and axons in the optic nerve. Strategies that delay or halt RGC loss have been recognized as potentially beneficial to preserve vision in glaucoma; however, the success of these approaches depends on an in-depth understanding of the mechanisms that lead to RGC dysfunction and death. In recent years, there has been an exponential increase in valuable information regarding the molecular basis of RGC death stemming from animal models of acute and chronic optic nerve injury as well as experimental glaucoma. The emerging landscape is complex and points at a variety of molecular signals - acting alone or in cooperation - to promote RGC death. These include: axonal transport failure, neurotrophic factor deprivation, toxic pro-neurotrophins, activation of intrinsic and extrinsic apoptotic signals, mitochondrial dysfunction, excitotoxic damage, oxidative stress, misbehaving reactive glia and loss of synaptic connectivity. Collectively, this body of work has considerably updated and expanded our view of how RGCs might die in glaucoma and has revealed novel, potential targets for neuroprotection. Copyright © 2011. Published by Elsevier Ltd.

  10. Facility of aerosol filtration

    Energy Technology Data Exchange (ETDEWEB)

    Duverger de Cuy, G; Regnier, J

    1975-04-18

    Said invention relates to a facility of aerosol filtration, particularly of sodium aerosols. Said facility is of special interest for fast reactors where sodium fires involve the possibility of high concentrations of sodium aerosols which soon clog up conventional filters. The facility intended for continuous operation, includes at the pre-filtering stage, means for increasing the size of the aerosol particles and separating clustered particles (cyclone separator).

  11. Mixture based outlier filtration

    Czech Academy of Sciences Publication Activity Database

    Pecherková, Pavla; Nagy, Ivan

    2006-01-01

    Roč. 46, č. 2 (2006), s. 30-35 ISSN 1210-2709 R&D Projects: GA MŠk 1M0572; GA MDS 1F43A/003/120 Institutional research plan: CEZ:AV0Z10750506 Keywords : data filtration * system modelling * mixture models Subject RIV: BD - Theory of Information http://library.utia.cas.cz/prace/20060165.pdf

  12. Detergent zeolite filtration plant

    OpenAIRE

    Stanković Mirjana S.; Pezo Lato L.

    2003-01-01

    The IGPC Engineering Department designed basic projects for detergent zeolite filtration plant, using technology developed in the IGPC laboratories. Several projects were completed: technological, machine, electrical, automation. On the basis of these projects, a production plant with a capacity of 75,000 t/y was manufactured, at "Zeolite Mira", Mira (VE), Italy, in 1997, for increasing detergent zeolite production, from 50,000 to 100,000 t/y. The main goal was to increase the detergent zeoli...

  13. [Secondary glaucoma in Paraguay. Etiology and incidence].

    Science.gov (United States)

    Strohl, A; Pozzi, S; Wattiez, R; Roesen, B; Miño de Kaspar, H; Klauss, V

    1999-06-01

    Glaucoma is the third-most-frequent cause of blindness in the world, with a total of 5.2 million blind people as a result of this disease; 80% live in developing countries. In Paraguay, after cataract it is the second-most-frequent-cause. Early detection of the risk factors and groups can help to avoid progress of this disease. Trauma, cataract and infectious uveitis represent special risks for developing secondary glaucoma, which is a more frequent cause of blindness in third-world countries than in industrialized nations. Until now there has been little data regarding the causes, disease course, and options for therapy. Therefore, secondary glaucoma was examined in Paraguay to obtain information on the situation in Latin America. The aim of the study was to explore the causes of secondary glaucoma for programs concerning prevention and therapy. From November 1996 to February 1997 patients with secondary glaucoma were examined at the University Hospital of Asunción, Paraguay. After the clinical examination the secondary glaucomas were classified. Patients with primary glaucoma were included in the same period of time as well in order to get the rate of secondary glaucoma. Altogether 293 patients were examined: 61 with secondary and 232 with primary glaucoma. The causes of secondary glaucoma in 73 eyes were: 20 (27%) with pseudoexfoliation glaucoma, 19 (26%) with post-traumatic glaucoma, 16 (22%) with neovascular glaucoma, 4 (5%) with lens-related glaucoma, 3 (4%) with glaucoma associated with ocular surgery, 2 (3%) with pigmentary and 2 (3%) with corticoid-induced glaucoma. A ratio of 4:1 primary glaucomas to secondary glaucomas was found. The development of special measures for prevention and early therapy is only possible if the causes of this severe disease are explored. The results of this study represent basic information and could help to introduce of prevention programs.

  14. Scanning laser polarimetry in glaucoma.

    Science.gov (United States)

    Dada, Tanuj; Sharma, Reetika; Angmo, Dewang; Sinha, Gautam; Bhartiya, Shibal; Mishra, Sanjay K; Panda, Anita; Sihota, Ramanjit

    2014-11-01

    Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White-on-white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far.

  15. The medical management of glaucoma

    African Journals Online (AJOL)

    medical and surgical interventions are accessible in the management of glaucoma. This article ..... Cannabinoids. With the recent attention cannabis has been receiving in the management of pain and other cancer related conditions, it.

  16. Apparatus for Crossflow Filtration Testing of High Level Waste Samples

    International Nuclear Information System (INIS)

    Nash, C.

    1998-05-01

    Remotely-operated experimental apparatuses for verifying crossflow filtration of high level nuclear waste have been constructed at the Savannah River Site (SRS). These units have been used to demonstrate filtration processes at the Savannah River Site, Oak Ridge National Laboratory, the Idaho National Engineering and Environmental Laboratory, and Pacific Northwest National Laboratory. The current work covers the design considerations for experimentation as well as providing results from testing at SRS

  17. Theoretical and experimental investigations into the filtration of the atmosphere within the containments of pressurized water reactors after serious reactor accidents

    International Nuclear Information System (INIS)

    Dillmann, H.G.; Pasler, H.

    1981-01-01

    For serious accidents in nuclear power stations equipped with pressurized water reactors and with boundary conditions assumed, a conservative evaluation was made of the condition of the atmosphere within the reactor containment, particularly referring to pressure, temperature, air humidity and activity release. Based on these data the loads were calculated of accident filter systems of different designs as a function of parameters such as the course of releases and the volume flow through the filter systems. A number of experimental results are indicated on the behaviour of iodine sorption materials under extreme conditions including the least favorable temperature, humidity and pressure derived from the calculations above. Reference is made to the targets of future R and D work on aerosol removal

  18. Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3T.

    Science.gov (United States)

    Mabray, M C; Uzelac, A; Talbott, J F; Lin, S C; Gean, A D

    2015-05-01

    To report on the MRI compatibility of the Ex-PRESS glaucoma filtration device, a tiny metallic implant placed into the anterior chamber of the eye that is much smaller than traditional glaucoma shunts, and to educate the radiology community regarding its appearance. Seven patients with Ex-PRESS glaucoma filtration devices were identified that had undergone MRI at San Francisco General Hospital/University of California San Francisco Medical Center by searching and cross-referencing the radiology reporting system and the electronic medical record. MRI images were reviewed for artefact interfering with interpretation. Ophthalmology examinations were reviewed for evidence of complications. Eighteen individual MRI examinations were performed during 12 unique MRI events on these 7 patients. 13/18 individual MRI examinations and 7/12 MRI events were performed at 3 T with the others performed at 1.5 T. Mean time from Ex-PRESS implantation to MRI was 17.5 months. Mean time from MRI to first ophthalmology examination was 1.1 months and from MRI to latest ophthalmology examination was 6.6 months. Susceptibility artefact did not interfere with image interpretation and no complications related to MRI were encountered. The Ex-PRESS glaucoma filtration device appears to be safe for MRI at 1.5 and 3 T and does not produce significant susceptibility artefact to affect diagnostic interpretation adversely. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Central corneal thickness among glaucoma patients attending ...

    African Journals Online (AJOL)

    AAU_CHS

    ocular pressure measurement and is different among different ethnic population and subtypes of glaucoma. The central corneal thickness of different subtypes of glaucoma at Menelik II Hospital ... Intraocular pressure is a key element in the.

  20. Optineurin, a multifunctional protein involved in glaucoma

    Indian Academy of Sciences (India)

    MADHU

    Glaucomas are a heterogeneous group of neurodegenerative eye diseases that ... with normal tension glaucoma (a sub-type of adult onset primary open angle .... identifies variants at CSF1, OPTN and TNFRSF11A as genetic risk factors for.

  1. Abrasive Particle Trajectories and Material Removal Non-Uniformity during CMP and Filtration Characteristics of CMP Slurries - A Simulation and Experimental Study

    Science.gov (United States)

    Rastegar, Vahid

    Nanoscale finishing and planarization are integral process steps in multilevel metallization designs for integrated circuit (IC) manufacturing since it is necessary to ensure local and global surface planarization at each metal layer before depositing the next layer. Chemical mechanical planarization (CMP) has been widely recognized as the most promising technology to eliminate topographic variation and has allowed the construction of multilevel interconnection structures with a more regularly stacked sequence, resulting in better device performance [1]. Understanding fundamental of the CMP mechanisms can offer guidance to the control and optimization of the polishing processes. CMP kinematics based on slurry distribution and particle trajectories have a significant impact on MRR profiles. In this work a mathematical model to describe particle trajectories during chemical mechanical polishing was developed and extended to account for the effect of larger particles, particle location changes due to slurry dispensing and in-situ conditioning. Material removal rate (MRR) and within wafer non-uniformity (WIWNU) were determined based on the calculated particle trajectory densities. Rotary dynamics and reciprocating motion were optimized to obtain best MRR uniformity. Edge-fast MRR profile was discussed based on mechanical aspect of CMP. Using the model, we also investigated the effect of variable rotational speeds of wafer and pad, and of large particles on WIWNU and scratch growth. It was shown that the presence of even a small portion of large particles can deteriorate the WIWNU significantly and also lead to more scratches. Furthermore, it was shown that the in-situ conditioning improves the uniformity of the polished wafers. Furthermore, a combined experimental and computational study of fibrous filters for removal of larger abrasive particles from aqueous dispersions, essential to minimize defects during chemical mechanical polishing, was performed. Dilute aqueous

  2. BWR condensate filtration studies

    International Nuclear Information System (INIS)

    Wilson, J.A.; Pasricha, A.; Rekart, T.E.

    1993-09-01

    Poor removal of particulate corrosion products (especially iron) from condensate is one of the major problems in BWR systems. The presence of activated corrosion products creates ''hot spots'' and increases piping dose rates. Also, fuel efficiency is reduced and the risk of fuel failure is increased by the deposit of corrosion products on the fuel. Because of these concerns, current EPRI guidelines call for a maximum of 2 ppb of iron in the reactor feedwater with a level of 0.5 ppb being especially desirable. It has become clear that conventional deep bed resins are incapable of meeting these levels. While installation of prefilter systems is an option, it would be more economical for plants with naked deep beds to find an improved bead resin for use in existing systems. BWR condensate filtration technologies are being tested on a condensate side stream at Hope Creek Nuclear Generating Station. After two years of testing, hollow fiber filters (HFF) and fiber matrix filters (FMF), and low crosslink cation resin, all provide acceptable results. The results are presented for pressure drop, filtration efficiency, and water quality measurements. The costs are compared for backwashable non-precoat HFF and FMF. Results are also presented for full deep bed vessel tests of the low crosslink cation resin

  3. Magnetic-seeding filtration

    Energy Technology Data Exchange (ETDEWEB)

    DePaoli, D.W.; Tsouris, C. [Oak Ridge National Lab., TN (United States); Yiacoumi, Sotira

    1997-10-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process.

  4. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    DePaoli, D.W.; Tsouris, C.; Yiacoumi, Sotira.

    1997-01-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process

  5. Salt disposition alternatives filtration at SRTC

    International Nuclear Information System (INIS)

    Walker, B. W.; Hobbs, D.

    2000-01-01

    Several of the prospective salt disposition alternative technologies require a monosodium titanate (MST) contact to remove strontium and actinides from inorganic salt solution feedstock. This feedstock also contains sludge solids from waste removal operations and may contain defoamers added in the evaporator systems. Filtration is required to remove the sludge and MST solids before sending the salt solution for further processing. This report describes testing performed using the Parallel Theological Experimental Filter (PREF). The PREF contains two single tube Mott sintered metal crossflow filters. For this test one filter was isolated so that the maximum velocities could be achieved. Previous studies showed slurries of MST and sludge in the presence of sodium tetraphenylborate (NaTPB) were filterable since the NaTPB slurry formed a filter cake which aided in removing the smaller MST and sludge particles. Some of the salt disposition alternative technologies do not use NaTPB raising the question of how effective crossflow filtration is with a feed stream containing only sludge and MST. Variables investigated included axial velocity, transmembrane pressure, defoamer effects, and solids concentration (MST and sludge). Details of the tests are outlined in the technical report WSRC-RP-98-O0691. Key conclusions from this study are: (1) Severe fouling of the Mott sintered metal filter did not occur with any of the solutions filtered. (2) The highest fluxes, in the range of .46 to 1.02 gpm/f 2 , were obtained when salt solution decanted from settled solids was fed to the filter. These fluxes would achieve 92 to 204 gpm filtrate production for the current ITP filters. The filtrate fluxes were close to the flux of 0.42 gpm/f 2 reported for In Tank Precipitation Salt Solution by Morrisey. (3) For the range of solids loading studied, the filter flux ranged from .04 to .17 gpm/f 2 which would result in a filtrate production rate of 9 to 31 gpm for the current HP filter. (4

  6. Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3 T

    International Nuclear Information System (INIS)

    Mabray, M.C.; Uzelac, A.; Talbott, J.F.; Lin, S.C.; Gean, A.D.

    2015-01-01

    Aim: To report on the MRI compatibility of the Ex-PRESS glaucoma filtration device, a tiny metallic implant placed into the anterior chamber of the eye that is much smaller than traditional glaucoma shunts, and to educate the radiology community regarding its appearance. Materials and methods: Seven patients with Ex-PRESS glaucoma filtration devices were identified that had undergone MRI at San Francisco General Hospital/University of California San Francisco Medical Center by searching and cross-referencing the radiology reporting system and the electronic medical record. MRI images were reviewed for artefact interfering with interpretation. Ophthalmology examinations were reviewed for evidence of complications. Results: Eighteen individual MRI examinations were performed during 12 unique MRI events on these 7 patients. 13/18 individual MRI examinations and 7/12 MRI events were performed at 3 T with the others performed at 1.5 T. Mean time from Ex-PRESS implantation to MRI was 17.5 months. Mean time from MRI to first ophthalmology examination was 1.1 months and from MRI to latest ophthalmology examination was 6.6 months. Susceptibility artefact did not interfere with image interpretation and no complications related to MRI were encountered. Conclusion: The Ex-PRESS glaucoma filtration device appears to be safe for MRI at 1.5 and 3 T and does not produce significant susceptibility artefact to affect diagnostic interpretation adversely. - Highlights: • The Ex-PRESS glaucoma filtration device is a tiny metallic orbital implant. • It can simulate a metallic orbital foreign body on imaging. • There is little information in the literature about it's MRI safety. • We report 18 MRIs performed on 7 patients including the first at 3 T. • Imaging appears to be safe at 1.5 and 3 T in patients with this device

  7. Normal-tension glaucoma (Low-tension glaucoma)

    Science.gov (United States)

    Anderson, Douglas R

    2011-01-01

    Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP), with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG), defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like), or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective. PMID:21150042

  8. Normal-tension glaucoma (Low-tension glaucoma

    Directory of Open Access Journals (Sweden)

    Anderson Douglas

    2011-12-01

    Full Text Available Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP, with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG, defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like, or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective.

  9. Novel surgical procedures in glaucoma: advances in penetrating glaucoma surgery.

    Science.gov (United States)

    Filippopoulos, Theodoros; Rhee, Douglas J

    2008-03-01

    Despite late modifications and enhancements, traditional penetrating glaucoma surgery is not without complications and is reserved for patients in whom pharmacologic treatment and/or laser trabeculoplasty do not suffice to control the intraocular pressure. This article critically reviews recent advances in penetrating glaucoma surgery with particular attention paid to two novel surgical approaches: ab interno trabeculectomy with the Trabectome and implantation of the Ex-PRESS shunt. Ab interno trabeculectomy (Trabectome) achieves a sustained 30% reduction in intraocular pressure by focally ablating and cauterizing the trabecular meshwork/inner wall of Schlemm's canal. It has a remarkable safety profile with respect to early hypotonous or infectious complications as it does not generate a bleb, but it can be associated with early postoperative intraocular pressure spikes that may necessitate additional glaucoma surgery. The Ex-PRESS shunt is more commonly implanted under a partial thickness scleral flap, and appears to have similar efficacy to standard trabeculectomy offering some advantages with respect to the rate of early complications related to hypotony. Penetrating glaucoma surgery will continue to evolve. As prospective randomized clinical trials become available, we will determine the exact role of these surgical techniques in the glaucoma surgical armamentarium.

  10. Health Benefits of Particle Filtration

    OpenAIRE

    Fisk, William J.

    2013-01-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and as...

  11. Provider Education about Glaucoma and Glaucoma Medications during Videotaped Medical Visits

    Directory of Open Access Journals (Sweden)

    Betsy Sleath

    2014-01-01

    Full Text Available Objective. The purpose of this study was to examine how patient, physician, and situational factors are associated with the extent to which providers educate patients about glaucoma and glaucoma medications, and which patient and provider characteristics are associated with whether providers educate patients about glaucoma and glaucoma medications. Methods. Patients with glaucoma who were newly prescribed or on glaucoma medications were recruited and a cross-sectional study was conducted at six ophthalmology clinics. Patients’ visits were videotape recorded and patients were interviewed after visits. Generalized estimating equations were used to analyze the data. Results. Two hundred and seventy-nine patients participated. Providers were significantly more likely to educate patients about glaucoma and glaucoma medications if they were newly prescribed glaucoma medications. Providers were significantly less likely to educate African American patients about glaucoma. Providers were significantly less likely to educate patients of lower health literacy about glaucoma medications. Conclusion. Eye care providers did not always educate patients about glaucoma or glaucoma medications. Practice Implications. Providers should consider educating more patients about what glaucoma is and how it is treated so that glaucoma patients can better understand their disease. Even if a patient has already been educated once, it is important to reinforce what has been taught before.

  12. Angle closure glaucoma in congenital ectropion uvea

    Directory of Open Access Journals (Sweden)

    Grace M. Wang

    2018-06-01

    Full Text Available Purpose: Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations: Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months and required additional surgery (cycloablation or trabeculectomy. Conclusions and importance: Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control. Keywords: Congenital ectropion uvea, Juvenile glaucoma, Angle-closure glaucoma, Glaucoma drainage device

  13. Immobilized Filters for Air Filtration

    National Research Council Canada - National Science Library

    Mahle, John J; Zaiee, Saeed

    2002-01-01

    ... (settling performance) and attrition resistance. The fabricated filter samples will be analyzed in order to determine the physical and chemical factors affecting mechanical strength and chemical filtration...

  14. Hot filtration 2

    International Nuclear Information System (INIS)

    Jimenez Rebagliati, Raul; Liberman, S.J.

    1982-01-01

    The magnetic filtration technique allows the removal of suspended magnetic species from a fluid at high flow rate and temperature. It is specially advantageous for water purification in systems such as thermonuclear and thermoelectric plants in which corrosion products must be removed from the heat transport and cooling circuits. Using diluted aqueous suspensions of magnetite, the behaviour of a ball matrix filter was studied as a function of flow rate, temperature and concentration of particles. The retention efficiency shows an exponential decay with fluid's velocity and viscosity in agreement with theory. Within the range of concentration considered, there is no change in the retention with concentration. Design parameters for filters according to plant's needs are obtained from the results of this study. (Author) [es

  15. Propionibacterium acnes endophthalmitis in Ahmed glaucoma valve.

    Science.gov (United States)

    Gutiérrez-Díaz, E; Montero-Rodríguez, M; Mencía-Gutiérrez, E; Fernández-González, M C; Pérez-Blázquez, E

    2001-01-01

    To report a case of Propionibacterium acnes endophthalmitis in a patient with an Ahmed glaucoma valve. A nine-year-old boy with bilateral congenital glaucoma, with an Ahmed glaucoma valve implanted in the left eye, had recurrent conjunctival dehiscence and endophthalmitis. Vitreous cultures demonstrated the presence of Propionibacterium acnes. This is the first reported case of Propionibacterium acnes endophthalmitis in an Ahmed glaucoma valve and the second one in a glaucoma drainage device. We strongly recommend using a patch graft to prevent and treat tube exposure. Conjunctival grafts may be useful to close the conjunctiva when there is marked scarring to prevent patch exposure and melting or extrusion.

  16. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  17. 40 CFR 141.173 - Filtration.

    Science.gov (United States)

    2010-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.173 Filtration. A public water system subject to the requirements of this subpart that does... treatment, direct filtration, slow sand filtration, or diatomaceous earth filtration. A public water system...

  18. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  19. Prevalence of glaucoma in a Nigerian hospital | Usifoh | Journal of ...

    African Journals Online (AJOL)

    Primary Open Angle Glaucoma (POAG) was the most common type of glaucoma (91.24%), followed by Normal Tension Glaucoma (NTG) with a prevalence of 3.23%. No significant association was found between age or sex and types of glaucoma. PACG and Juvenile glaucoma remains relatively rare accounting for only ...

  20. Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma

    Directory of Open Access Journals (Sweden)

    Amir Pirouzian

    2008-03-01

    Full Text Available Amir Pirouzian1, Joseph L Demer21Department of Ophthalmology, San Diego Children’s Hospital, San Diego, UCSD, San Diego, CA, USA; 2Department of Ophthalmology, Jules Stein Eye Institute, UCLA, Los Angeles, CA, USAPurpose: To describe clinical findings after Ahmed valve drainage implantation in children.Design: All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma ValveTM S2 model insertion for uncontrolled primary or secondary glaucoma.Results: A total of 6 patients were identified, ranging in age from 2–15 years. Mean follow-up time averaged from 2–5 years from the time of tube insertion. Three patients exhibited pupillary peaking towards the tube of the valve. All patients required additional surgery or additional medications to control intraocular pressure. Lenticular opacification near the tube site developed in one patient. Gradual tube extrusion was also noted in another two patients.Conclusion: Multiple clinical events follow the Ahmed valve insertion in children. Pupillary irregularity is the most commonly noted event in this series. To avoid or reduce the risk of this complication, additional or modification of surgical procedures could be considered. The mechanism of such occurrence will further be discussed.Keywords: Ahmed Glaucoma Valve, children, pediatric glaucoma

  1. [Basic and clinical studies of pressure-independent damaging factors of open angle glaucoma].

    Science.gov (United States)

    Araie, Makoto

    2011-03-01

    Pathogenesis of open-angle glaucoma involves both pressure-dependent damaging factors and pressure-independent damaging factors. The high prevalence of open-angle glaucoma with normal pressure (normal-tension glaucoma) in Japan implies that treatment of pressure-independent damaging factors in Japanese open-angle glaucoma patients is of importance. In an attempt to investigate the roles of pressure-independent damaging factors in open-angle glaucoma, we carried out basic and clinical studies and obtained the following results. 1. The rate of deterioration of visual field after trabeculectomy in normal tension glaucoma patients with post-operative intraocular pressure (IOP) of 10 mmHg was found to be -0.25 dB/year of mean deviation (MD), suggesting that contribution of pressure-independent damaging factors to the deterioration of MD in open-angle glaucoma is around -0.25 dB/year of mean deviation (MD). 2. Experiments using isolated purified cultured retinal ganglion cells (RGCs) indicated that calcium-channel blockers and some of antiglaucoma drugs showed neuroprotective effects on RGCs at concentrations of 0.01 microM or higher. 3. In mice, damage to RGCs resulted in secondary degeneration of neurons and activation of glial cells in the lateral geniculate nucleous (LGN) and superior colliculus, and these secondary changes in the central nervous system (CNS) due to RGC damage was partly ameliorated by systemic administration of memantine. 4. Mice experimental high IOP glaucoma models could be established using laser irradiation of the limbal area, and the usefulness of Tonolab in IOP measurements of mice eye was confirmed. 5. Monkey experimental high IOP glaucoma models revealed that in the glaucomatous optic nerve head vaso-constrictive reactions to an alpha-1 agonist was abolished, while vasodilative reaction to a prostaglandin FP receptor agonist was retained. 6. In monkeys with experimental high IOP glaucoma, secondary damage to neurons in the LGN and the glial

  2. Diesel fuel filtration system

    International Nuclear Information System (INIS)

    Schneider, D.

    1996-01-01

    The American nuclear utility industry is subject to tight regulations on the quality of diesel fuel that is stored at nuclear generating stations. This fuel is required to supply safety-related emergency diesel generators--the backup power systems associated with the safe shutdown of reactors. One important parameter being regulated is the level of particulate contamination in the diesel fuel. Carbon particulate is a natural byproduct of aging diesel fuel. Carbon particulate precipitates from the fuel's hydrocarbons, then remains suspended or settles to the bottom of fuel oil storage tanks. If the carbon particulate is not removed, unacceptable levels of particulate contamination will eventually occur. The oil must be discarded or filtered. Having an outside contractor come to the plant to filter the diesel fuel can be costly and time consuming. Time is an even more critical factor if a nuclear plant is in a Limiting Condition of Operation (LCO) situation. A most effective way to reduce both cost and risk is for a utility to build and install its own diesel fuel filtration system. The cost savings associated with designing, fabricating and operating the system inhouse can be significant, and the value of reducing the risk of reactor shutdown because of uncertified diesel fuel may be even higher. This article describes such a fuel filtering system

  3. Pathophysiology, diagnosis, and management of glaucoma associated with Sturge-Weber syndrome.

    Science.gov (United States)

    Javaid, Usman; Ali, Muhammad Hassaan; Jamal, Samreen; Butt, Nadeem Hafeez

    2018-02-01

    Sturge-Weber syndrome (SWS), also known as encephalotrigeminal angiomatosis, is a condition which includes leptomeningeal hemangioma, facial angiomatosis or nevus flammeus, and ocular changes. SWS can lead to severe complications of anterior segment involving conjunctiva and eyelids, whereas posterior segment of the eye may also be affected by diffuse choroidal hemorrhages. This article was written with the objectives to determine the pathophysiology, diagnosis, and treatment of glaucoma associated with this rare and challenging disorder. A detailed literature search was conducted on PubMed, EMBASE, Cochrane Library, and Google Scholar using the key words. Forty-five articles matched our inclusion criteria that were included in this systematic review. Glaucoma is the one of the commonest ocular manifestations of SWS. It is caused by anterior chamber malformations, increased pressure in the episcleral veins, and changes in ocular hemodynamics. Glaucoma associated with SWS is usually congenital but can develop adults as well. The treatment of glaucoma associated with SWS is quite challenging because of early-onset, severe visual field impairment at the time of diagnosis, and unresponsiveness to standard medical treatment. Several surgical procedures have been devised but the long-term control of the intraocular pressure and visual function remain unsatisfactory. Modifications in the filtration surgery techniques and use of newer anti-fibrotic agents have produced good control of intraocular pressure. Management of glaucoma associated with SWS is multi-dimensional and needs both medical and surgical interventions for better control. The treatment should be devised on case to case basis depending upon the intraocular pressure, stage of the disease, and type of glaucoma.

  4. Efficient filtration system for paraffin-catalyst slurry separation

    Directory of Open Access Journals (Sweden)

    Khodagholi Mohammad Ali

    2013-01-01

    Full Text Available The filtration efficiency for separating liquid paraffin (or water from a slurry consisting of 25 weight% spherical alumina in a Slurry Bubble Column Reactor (SBCR comprised of a cylindrical tube of 10 cm diameter and 150 cm length was studied. Various differential pressures (ΔP were applied to two separate tubular sintered metal stainless steel filter elements with nominal pore size of 4 and 16μm. The experimental results disclosed that the rate of filtrations increased on applying higher differential pressure to the filter element. Albeit this phenomenon is limited to moderate ΔPs and for ΔP more than 1 bar is neither harmful nor helpful. The highest filtration rates at ΔPs higher than 1 bar were 170 and 248 ml/minute for 4 and 16μm respectively. Using water as the liquid in slurry the rate of filtration enhanced to 4 folds, and this issue reveals impact of viscosity on filtration efficiency clearly. In all situations, the total amount of particles present in the filtrate part never exceeded a few parts per million (ppm. The statistical analysis of the SEM image of the filtrate indicated that by applying higher pressure difference to the filter element the frequency percent of larger particle size increases. The operation of filter cake removing was performed with back flashing of 300 ml of clean liquid with pressures of 3-5 bar of N2 gas.

  5. SQSTM1 Mutations and Glaucoma.

    Directory of Open Access Journals (Sweden)

    Todd E Scheetz

    Full Text Available Glaucoma is the most common cause of irreversible blindness worldwide. One subset of glaucoma, normal tension glaucoma (NTG occurs in the absence of high intraocular pressure. Mutations in two genes, optineurin (OPTN and TANK binding kinase 1 (TBK1, cause familial NTG and have known roles in the catabolic cellular process autophagy. TKB1 encodes a kinase that phosphorylates OPTN, an autophagy receptor, which ultimately activates autophagy. The sequestosome (SQSTM1 gene also encodes an autophagy receptor and also is a target of TBK1 phosphorylation. Consequently, we hypothesized that mutations in SQSTM1 may also cause NTG. We tested this hypothesis by searching for glaucoma-causing mutations in a cohort of NTG patients (n = 308 and matched controls (n = 157 using Sanger sequencing. An additional 1098 population control samples were also analyzed using whole exome sequencing. A total of 17 non-synonymous mutations were detected which were not significantly skewed between cases and controls when analyzed separately, or as a group (p > 0.05. These data suggest that SQSTM1 mutations are not a common cause of NTG.

  6. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  7. PSEUDOEXFOLIATION SYNDROME IN ETHIOPIAN GLAUCOMA ...

    African Journals Online (AJOL)

    1999-05-05

    May 5, 1999 ... of a systemic disorder involving an aberrant connective- tissue metabolism ... were included in this study, except those secondary glaucoma cases due to trauma, ... a1(17), found the five and 10 year cumulative probabilities of ...

  8. [Perimetric changes in advanced glaucoma].

    Science.gov (United States)

    Feraru, Crenguta Ioana; Pantalon, Anca

    2011-01-01

    The evaluation of various perimetric aspects in advanced glaucoma stages correlated to morpho-functional changes. MATHERIAL AND METHOD: Retrospective clinical trial over a 10 months time period that included patients with advanced glaucoma stages, for which there have been recorded several computerised visual field tests (central 24-2 strategy, 10-2 strategy with either III or V--Goldman stimulus spot size) along with other morpho-funtional ocular paramaters: VA, lOP optic disk analysis. We included in our study 56 eyes from 45 patients. In most cases 89% it was an open angle glaucoma (either primary or secondary) Mean visual acuity was 0.45 +/- 0.28. Regarding the perimetric deficit 83% had advanced deficit, 9% moderate and 8% early visual changes. As perimetric type of defect we found a majority with general reduction of sensitivity (33 eyes) + ring shape scotoma. In 6 eyes (10.7%) having left only a central isle of vision we performed the central 10-2 strategy with III or V Goldmann stimulus spot size. Statistic analysis showed scarce correlation between the visual acuity and the quantitative perimetric parameters (MD and PSD), and variance analysis found present a multiple correlation parameter p = 0.07 that proves there is no liniary correspondence between the morpho-functional parameters: VA-MD(PSD) and C/D ratio. In advanced glaucoma stages, the perimetric changes are mostly severe. Perimetric evaluation is essential in these stages and needs to be individualised.

  9. Problems of multiphase fluid filtration

    CERN Document Server

    Konovalov, AN

    1994-01-01

    This book deals with a spectrum of problems related to the mathematical modeling of multiphase filtration. Emphasis is placed on an inseparable triad: model - algorithm - computer code. An analysis of new and traditional filtration problems from the point of view of both their numerical implementation and the reproduction of one or another technological characteristics of the processes under consideration is given. The basic principles which underlie the construction of efficient numerical methods taking into account the filtration problems are discussed: non-evolutionary nature, degeneration,

  10. [Surgical treatment of certain forms of secondary glaucoma].

    Science.gov (United States)

    Dushin, N V; Trubilin, V N; Beliaev, V S; Barashkov, V I; Gonchar, P A; Frolov, M A; Kravchinina, V V; Semin, S B

    2003-01-01

    The technique of penetrating deep sclerectomy with suprachoroidal explanto-drainage as well as the results of postoperative follow-up, exceeding 2 years, and of the early-described sinustrabeculectomy with regulated filtration are presented in the article. Operations were made on 59 eyes (58 patients aged 13 to 70) with the below forms of secondary glaucomas: new-vascular, postuveal, dystrophic (at retinal detachment), posttraumatic (contusion-type), phakotopic, postoperative (aphakic), and hemolytic. The below goals were set while elaborating the methods: the possibility to regulate postoperatively the intraocular pressure, elimination of the pain syndrome, the organ-preserving effect, stabilization of the clinical cause and shaping-up of reliable drainage paths. The authors registered a positive effect in 87.5% of cases.

  11. Clinical observation of two operation methods for neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2013-11-01

    Full Text Available AIM: To evaluate the clinical effect of two different surgical treatments for neovascular glaucoma(NVG.METHODS: A total of 30 NVG inpatients(30 eyesat our hospital from April 2008 to December 2011 were reviewed. Patients were divided into two groups according to the different surgical treatments. In group A, 12 cases(12 eyeswere treated with Ahmed glaucoma valve(AGVimplantation and in group B, 18 cases(18 eyeswere treated with semiconductor diode laser photocoagulation transscleral cyclophotocoagulation(TSCPC. Intraocular pressure, visual acuity and complications were compared between two groups postoperatively.RESULTS: The postoperative IOP was significantly lower in each group(PPP>0.05in IOP 1 month after surgery. Visual acuity: in group A, the visual acuity was improved in 3 eyes, unchanged in 7 eyes and worsened in 2 eyes.; in group B, the visual acuity was improved in 3 eyes, unchanged in 12 eyes and worsened in 3 eyes. Postoperative complications: in group A, eyeball pain and corneal edema were found in 5 cases(41.7%, shallow anterior chamber in 3 cases(25%, anterior chamber fibroid exudation in 2 cases(16.7%, hyphema in 3 cases(25%; in group B, eyeball pain atearly stage after surgery were found in 10 cases(55.6% , corneal edema in 11 cases(61.1%, anterior chamber fibroid exudation in 5 cases(27.8%, hyphema in 6 cases(33.3%.CONCLUSION: AGV implantation and TSCPC are both effective surgical treatment methods for NVG. AGV implantation is a filtration surgery, which is relatively safe. TSCPC is more economical and suitable for glaucoma of advanced or absolute stage.

  12. Filtration characteristics in membrane bioreactors

    NARCIS (Netherlands)

    Evenblij, H.

    2006-01-01

    Causes of and remedies for membrane fouling in Membrane Bioreactors for wastewater treatment are only poorly understood and described in scientific literature. A Filtration Characterisation Installation and a measurement protocol were developed with the aim of a) unequivocally determination and

  13. Latest aspects of mechanical filtration

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available The aim of this study was to describe and unify all knowledge about mechanic filtration. The first part deals with the parameters and properties of filtration. Here some important basic concepts are explained such as pressure gradient, filter life, etc. There’s also a description of convenient filtration technology for coarse and fine materials, such as sand, smoke or soot. The second part primarily focuses on the real use and application of filters for liquid and gaseous media. The differences in construction between different types of filters for filtration of fuels, oils, hydraulic fluids, air and cabin filters are described. The last section is focused mainly on new materials for the production of filters. These materials are ceramic or nanomaterials, which can actually be enriched for example with antibacterial silver or some fungicides.

  14. Progress of inflammatory cytokines in glaucoma

    Directory of Open Access Journals (Sweden)

    Ping Hu

    2015-12-01

    Full Text Available Glaucomais a group of diseases characterized by optic nerve damage and visual field defect, and pathological high intraocular pressure is a risk factor for glaucoma. Glaucoma is affected by the interaction of multiple genes and environmental factors, and inflammation may be involved in the pathogenesis of glaucoma. A great deal of studies have confirmed that high expression of connective tissue growth factor(CTGF, tumor necrosis factor-α(TNF-α, interleukins(ILs, nuclear factor-kappa B(NF-κBand various cytokines in the aqueous humor of patients with glaucoma, which have a close correlation with pathogenesis of glaucoma.This article reviews the progress of inflammatory cytokines and their relationship with glaucoma.

  15. Health benefits of particle filtration.

    Science.gov (United States)

    Fisk, W J

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, for example, 7% to 25%. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air. Published 2013. This article is a US Government work and is in the public domain in the USA.

  16. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percent age improvement in health outcomes is typically modest, for example, 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  17. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, e.g., 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  18. Peripheral iridotomy for pigmentary glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lindsley, Kristina

    2016-01-01

    Background Glaucoma is a chronic optic neuropathy characterized by retinal ganglion cell death resulting in damage to the optic nerve head and the retinal nerve fiber layer. Pigment dispersion syndrome is characterized by a structural disturbance in the iris pigment epithelium (the densely pigmented posterior surface of the iris) that leads to dispersion of the pigment and its deposition on various structures within the eye. Pigmentary glaucoma is a specific form of open-angle glaucoma found in patients with pigment dispersion syndrome. Topcial medical therapy is usually the first-line treatment; however, peripheral laser iridotomy has been proposed as an alternate treatment. Peripheral laser iridotomy involves creating an opening in the iris tissue to allow drainage of fluid from the posterior chamber to the anterior chamber and vice versa. Equalizing the pressure within the eye may help to alleviate the friction that leads to pigment dispersion and prevent visual field deterioration. However, the effectiveness of peripheral laser iridotomy in reducing the development or progression of pigmentary glaucoma is unknown. Objectives The objective of this review was to assess the effects of peripheral laser iridotomy compared with other interventions, including medication, trabeculoplasty, and trabeculectomy, or no treatment, for pigment dispersion syndrome and pigmentary glaucoma. Search methods We searched a number of electronic databases including CENTRAL, MEDLINE and EMBASE and clinical trials websites such as (mRCT) and ClinicalTrials.gov. We last searched the electronic databases on 2 November 2015. Selection criteria We included randomized controlled trials (RCTs) that had compared peripheral laser iridotomy versus no treatment or other treatments for pigment dispersion syndrome and pigmentary glaucoma. Data collection and analysis We used standard methodological procedures for systematic reviews. Two review authors independently screened articles for eligibility

  19. The Philadelphia Glaucoma Detection and Treatment Project

    Science.gov (United States)

    Waisbourd, Michael; Pruzan, Noelle L.; Johnson, Deiana; Ugorets, Angela; Crews, John E.; Saaddine, Jinan B.; Henderer, Jeffery D.; Hark, Lisa A.; Katz, L. Jay

    2016-01-01

    Purpose To evaluate the detection rates of glaucoma-related diagnoses and the initial treatments received in the Philadelphia Glaucoma Detection and Treatment Project, a community-based initiative aimed at improving the detection, treatment, and follow-up care of individuals at risk for glaucoma. Design Retrospective analysis. Participants A total of 1649 individuals at risk for glaucoma who were examined and treated in 43 community centers located in underserved communities of Philadelphia. Methods Individuals were enrolled if they were African American aged ≥50 years, were any other adult aged ≥60 years, or had a family history of glaucoma. After attending an informational glaucoma workshop, participants underwent a targeted glaucoma examination including an ocular, medical, and family history; visual acuity testing, intraocular pressure (IOP) measurement, and corneal pachymetry; slit-lamp and optic nerve examination; automated visual field testing; and fundus color photography. If indicated, treatments included selective laser trabeculoplasty (SLT), laser peripheral iridotomy (LPI), or IOP-lowering medications. Follow-up examinations were scheduled at the community sites after 4 to 6 weeks or 4 to 6 months, depending on the clinical scenario. Main Outcome Measures Detection rates of glaucoma-related diagnoses and types of treatments administered. Results Of the 1649 individuals enrolled, 645 (39.1%) received a glaucoma-related diagnosis; 20.0% (n = 330) were identified as open-angle glaucoma (OAG) suspects, 9.2% (n = 151) were identified as having narrow angles (or as a primary angle closure/suspect), and 10.0% (n = 164) were diagnosed with glaucoma, including 9.0% (n = 148) with OAG and 1.0% (n = 16) with angle-closure glaucoma. Overall, 39.0% (n = 64 of 164) of those diagnosed with glaucoma were unaware of their diagnosis. A total of 196 patients (11.9%) received glaucoma-related treatment, including 84 (5.1%) who underwent LPI, 13 (0.8%) who underwent SLT

  20. Angle closure glaucoma in congenital ectropion uvea.

    Science.gov (United States)

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  1. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

    Directory of Open Access Journals (Sweden)

    Tojo N

    2015-03-01

    Full Text Available Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS.Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea 

  2. Malignant glaucoma after cataract surgery.

    Science.gov (United States)

    Varma, Devesh K; Belovay, Graham W; Tam, Diamond Y; Ahmed, Iqbal Ike K

    2014-11-01

    To report a series of eyes that developed malignant glaucoma after cataract surgery. Private academic practice, Toronto, Ontario, Canada. Retrospective case series. Eyes that developed malignant glaucoma after cataract surgery were treated with medical therapy. This was followed by laser iridozonulohyaloidotomy, anterior chamber reformation and intraocular lens (IOL) pushback, and finally with surgical iridozonulohyaloidovitrectomy if all other measures were unsuccessful. Refraction, intraocular pressure (IOP), gonioscopy, and anterior chamber depth (ACD) by anterior segment optical coherence tomography were analyzed before treatment and after treatment. The study evaluated 20 eyes of 18 female patients aged 44 to 86 years. Preoperatively, the mean refraction was +3.11 diopters (D) ± 2.89 (SD), the mean axial length was 21.30 ± 1.40 mm, and all eyes had narrow or closed angles. Malignant glaucoma was diagnosed a mean of 5.8 ± 7.1 weeks postoperatively. At diagnosis, the mean refraction was -2.15 ± 2.95 D; the mean ACD, 2.49 ± 0.72 mm; and the mean IOP, 28.3 ± 10.8 mm Hg on a mean of 1.3 ± 1.6 medications. Two eyes responded to cycloplegia, 7 to laser iridozonulohyaloidotomy, and 6 to anterior chamber reformation-IOL pushback; 5 eyes required vitrectomy. Posttreatment, the mean refraction was -0.56 ± 1.07 D; the mean ACD, 3.30 ± 0.50 mm; and the mean IOP, 14.4 ± 4.60 mm Hg on a mean of 1.2 ± 1.4 medications. Cycloplegia was discontinued in 17 eyes. Malignant glaucoma can occur after phacoemulsification and presents with myopic surprise, anterior chamber shallowing and, possibly, elevated IOP. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Update on normal tension glaucoma

    Directory of Open Access Journals (Sweden)

    Jyotiranjan Mallick

    2016-01-01

    Full Text Available Normal tension glaucoma (NTG is labelled when typical glaucomatous disc changes, visual field defects and open anterior chamber angles are associated with intraocular pressure (IOP constantly below 21 mmHg. Chronic low vascular perfusion, Raynaud's phenomenon, migraine, nocturnal systemic hypotension and over-treated systemic hypertension are the main causes of normal tension glaucoma. Goldmann applanation tonometry, gonioscopy, slit lamp biomicroscopy, optical coherence tomography and visual field analysis are the main tools of investigation for the diagnosis of NTG. Management follows the same principles of treatment for other chronic glaucomas: To reduce IOP by a substantial amount, sufficient to prevent disabling visual loss. Treatment is generally aimed to lower IOP by 30% from pre-existing levels to 12-14 mmHg. Betaxolol, brimonidine, prostaglandin analogues, trabeculectomy (in refractory cases, systemic calcium channel blockers (such as nifedipine and 24-hour monitoring of blood pressure are considered in the management of NTG. The present review summarises risk factors, causes, pathogenesis, diagnosis and management of NTG.

  4. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  5. Glaucoma and dry eye disease: the role of preservatives in glaucoma medications

    Directory of Open Access Journals (Sweden)

    Ratna Sitompul

    2011-11-01

    Full Text Available Glaucoma is a common cause of irreversible blindness with increasing prevalence. Some of glaucoma patients will also experience dry eye. Dry eye is the most frequent side effect related to benzalkonium chloride (BAC-containing eye drop  used for glaucoma patients. In addition, glaucoma and dry eyes have shared risk factors that are old age and female. Dry eye among glaucoma patients need to be treated promptly as it produces discomfort, reduces patients’ compliance and   decreases success rate of glaucoma therapy. Dry eye symptoms can be treated by applying preservative-free eye drop, giving combination of preservative containing and preservative-free eye drop to reduce BAC exposure, prescribing artificial tear and conducting surgery to minimize or eliminate the need of topical medication. (Med J Indones 2011; 20:302-5Keywords: benzalkonium chloride, dry eye, glaucoma

  6. Prevalence of open angle glaucoma in accompanying first degree relatives of patients with glaucoma

    Directory of Open Access Journals (Sweden)

    Franciele Vegini

    2008-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the prevalence of open angle glaucoma in first-degree relatives accompanying POAG patients during routine examination in a reference hospital. METHOD: First-degree relatives of primary open angle glaucoma patients who accompanied their relatives to the glaucoma service of a reference hospital were screened for glaucoma. RESULTS: One-hundred and one first-degree relatives were examined, of which 56.4% had never had their intraocular pressure measured. 10.9% had previously been diagnosed with glaucoma, and 5.9% were newly diagnosed during this study. CONCLUSIONS: The eye examination of first-degree relatives identified a significant percentage of individuals with glaucoma. Despite being first-degree relatives of glaucoma patients, 56.4% of the companions had never had their eye pressure measured, demonstrating a lack of awareness about this disease.

  7. Glaucoma and clinical characteristics in Vietnamese Americans.

    Science.gov (United States)

    Peng, Pai-Huei; Manivanh, Richard; Nguyen, Ngoc; Weinreb, Robert N; Lin, Shan C

    2011-08-01

    To assess the proportions of glaucoma types and clinical characteristics in Vietnamese Americans in a single-center, retrospective study. Medical charts of Vietnamese-American patients who visited a single private practice in Northern California from 1998-2007 were reviewed. The main outcome measures included the distribution and characteristics of glaucoma types, and clinical parameters associated with the presence of various glaucomas. Data from 2247 patients aged 18-98 years were reviewed. Glaucoma was determined for 305 patients (13.6%). Among this group, 54.8% had primary open-angle glaucoma (POAG), 26.9% had primary angle-closure glaucoma (PACG), 13.4% had mixed mechanism glaucoma (MMG), and 4.9% had secondary glaucoma. In the MMG group (41 patients), 27 patients who initially had open angles developed narrow angles and underwent laser peripheral iridotomy (LPI) with a mean follow up of 6.4 years from the time of iridotomy. The other 13 patients had glaucoma progression with open angles after LPI. One POAG patient had neovascular glaucoma due to retinal vein occlusion several years later. Compared to the PACG group, the MMG group had significantly lower baseline intraocular pressure (25.0 vs. 20.2 mmHg, p = 0.007) but with no difference in biometry. POAG is the major type of glaucoma in this clinic-based Vietnamese population. However, Vietnamese appear to have a relatively higher proportion of PACG than Caucasians and those of African descent. It is recommended that gonioscopy be part of the regular eye check-up for adult Vietnamese patients.

  8. Design of low cost glaucoma screening

    NARCIS (Netherlands)

    Niessen, A. G.; Langerhorst, C. T.; Geijssen, H. C.; Greve, E. L.

    1997-01-01

    In 1991 the Netherlands Glaucoma Patient Association organized a glaucoma screening survey. This survey was designed to evaluate the effectiveness of a low cost screening setting. During a screening period of 8 days, 1259 subjects over the age of 49 years were examined by a team of

  9. GLAUCOMA IN PSEUDOEXFOLIATION- CLINICAL PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Balasubramanian M. Manickavelu

    2018-01-01

    Full Text Available BACKGROUND Pseudoexfoliation is one of the common cause of secondary open-angle glaucoma worldwide with a mean progression rate higher than primary open-angle glaucoma. In India, prevalence rate of pseudoexfoliation is around 2% (Hiller et al. In South India, the prevalence rate is 6% in >40 years of age as per Krishnadas et al in 2003. The aim of the study is to study the demographic aspects of pseudoexfoliation, the frequency of glaucoma in patients with pseudoexfoliation syndrome and to assess the treatment response in pseudoexfoliation syndrome. MATERIALS AND METHODS The study was conducted among 96 patients with pseudoexfoliation who attended OP Department of Ophthalmology, Government Tiruvannamalai Medical College and Hospital, Tiruvannamalai, from January 2017 to June 2017. Complete ocular examination with visual acuity, anterior segment examination, intraocular pressure, gonioscopy, fundus examination, central corneal thickness, visual field, ultrasound B scan and ultrasound biomicroscopy was done. RESULTS Incidence of glaucoma is more common in pseudoexfoliation and most of them have open angles. All patients with pseudoexfoliation should undergo complete glaucoma evaluation for early detection. Further ophthalmologist should focus on detection of pseudoexfoliation, since it is related to high risk of operative complication. CONCLUSION Incidence of glaucoma is more in pseudoexfoliation with most common bilateral presentation with open angles with recalcitrant intraocular pressure. Severity of optic nerve damage and with progression of field defects appeared to be more compared to primary open-angle glaucoma. Better response to combination drug therapy and surgical therapy than primary open-angle glaucoma.

  10. Determinants of glaucoma awareness in urban punjab

    International Nuclear Information System (INIS)

    Farooq, S.; Jaffar, S.; Kausar, A.

    2015-01-01

    To assess the awareness about glaucoma and the factors affecting it in urban Punjab population. Study Design: Cross-sectional study. Place and Duration of Study: Study was conducted in March-April 2011 in Rawalpindi District Punjab, Pakistan. Material and Methods: Glaucoma awareness study was conducted on urban population of Rawalpindi, Islamabad, Lahore and Taxila. Individuals belonging to medical profession (doctors, nurses and paramedics etc) were not included. Demographic details and educational status of all participants were documented. A brief structured close-ended study questionnaire was used to collect information about their awareness of risk factors, treatment aspects and complication of glaucoma. Results: There were 729 participants in the study. Majority were females (60.1%) and adults (76.1%). Literacy level of 40.2% was up to matriculate level. The study indicated that the awareness level about glaucoma was low especially about the recognition of high-risk groups and symptoms. Only one-third of respondents i.e. 32.6% had an idea about the symptoms of the disease and 27.4% participants had awareness of glaucoma as a blinding eye disease. Determinants of glaucoma awareness amongst study participants were gender, age, education level and occupation. Conclusion: Awareness of glaucoma was quite low among the urban population in Punjab. There is need of increased public health education to reduce glaucoma associated blindness and its burden on society. (author)

  11. Normal tension glaucoma and Alzheimer disease

    DEFF Research Database (Denmark)

    Bach-Holm, Daniella; Kessing, Svend Vedel; Mogensen, Ulla Brasch

    2012-01-01

    Purpose: To investigate whether normal tension glaucoma (NTG) is associated with increased risk of developing dementia/Alzheimer disease (AD). Methods: A total of 69 patients with NTG were identified in the case note files in the Glaucoma Clinic, University Hospital of Copenhagen (Rigshospitalet...

  12. New pharmacotherapy for the treatment of glaucoma.

    Science.gov (United States)

    Schehlein, Emily M; Novack, Gary; Robin, Alan L

    2017-12-01

    Glaucoma is the second leading cause of blindness in the world and current pharmacotherapies for glaucoma have remained relatively unchanged (with the exception of fixed combinations of previously available medications) since the mid-1990s with the development of prostaglandin analogues. Now, with both new formulations and new classes of medications with novel mechanisms of action, the medical therapy of glaucoma may be heralding a new dawn in medical management. Areas covered: This review outlines new topical therapies for intraocular pressure (IOP) lowering treatment, in addition to new formulations, preservative-free options, and advances in glaucoma medical therapy delivery. We performed a comprehensive search for published studies for glaucoma medical therapy using the electronic database PubMed. A manual search for each therapy or delivery system was also performed. Expert commentary: These advances in glaucoma therapy have the potential to overcome many barriers to glaucoma's medical care, particularly in terms of adherence. However, both time and research are needed to prove the relative efficacy and safety of these new pharmacotherapies and products, helping us decide their role in the treatment of elevated intraocular pressure. We are hopeful that these new developments in therapy may bring more options for glaucoma medical therapy.

  13. Chronic Glaucoma in Dogs: Relationships Between Histologic Lesions and the Gonioscopic Diagnosis of Pectinate Ligament Dysplasia.

    Science.gov (United States)

    Bauer, B S; Sandmeyer, L S; Philibert, H; Feng, C X; Grahn, B H

    2016-11-01

    Pectinate ligament dysplasia (PLD) is a common cause of canine glaucoma and the definitive clinical diagnosis is based on gonioscopy. Although the histologic lesions of PLD have been described, it has not been determined whether these changes are specific for PLD or if similar histologic changes can develop as a consequence of secondary glaucoma. The filtration angles of 61 enucleated canine globes with chronic glaucoma were evaluated with light microscopy by 3 examiners who were masked to the clinical history, signalment, and gonioscopic results. A histologic diagnosis of PLD versus non-PLD was determined by each examiner based on previously reported morphologic criteria and compared with the clinical gonioscopic diagnosis. Of the 61 enucleated glaucomatous eyes, 40 were clinically diagnosed with PLD. For all 3 examiners, a histologic diagnosis of PLD corresponded poorly with the clinical diagnosis of PLD (range of kappa score: 0.149-0.269; range of AUC: 0.592-0.621). There was no difference between examiners in their ability to correctly diagnose PLD histologically (P = .978). A fair degree of agreement was noted among examiners in obtaining their suspected histologic diagnosis of PLD (kappa score 0.256). No individual or sets of histologic ICA features were consistent with clinical PLD. The results indicate the histologic ICA changes proposed to be characteristic of PLD are also noted in canine globes affected with chronic secondary glaucoma. Therefore, using routine histologic evaluation, a histologic diagnosis of PLD is not possible in the face of chronic canine glaucoma. © The Author(s) 2016.

  14. Managing high risk glaucoma with the Ahmed valve implant: 20 years of experience.

    Science.gov (United States)

    Rotsos, Tryfon; Tsioga, Anastasia; Andreanos, Konstantinos; Diagourtas, Andreas; Petrou, Petros; Georgalas, Ilias; Papaconstantinou, Dimitrios

    2018-01-01

    To estimate the efficacy and safety of the Ahmed implant in patients with high risk for failure after glaucoma surgery. In 342 eyes of 342 patients with refractory glaucoma, even with application of medical treatment, the Ahmed valve was introduced for intraocular pressure (IOP) control, in the period of the last 20y. The nature of glaucoma was neovascular in 162 eyes, pseudophakic or aphakic in 49 eyes, inflammatory in 29 eyes and non working previous antiglaucomatic surgical interventions in 102 eyes. Follow-up ranged from 18 to 120mo with a mean follow-up of 63.2mo. IOP before the operation decreased from 31.6±10.4 mm Hg to 18.3±5.4 mm Hg (no systemic treatment) at the end of follow up period. When we compared the IOP values before the operation using ANOVA showed statistically significant difference ( P glaucoma, 63.2% in aphakic glaucoma and 73.8% in non working previous antiglaucomatic surgical interventions. Complications due to the implant were: serous choroidal detachment in 14.8%, blockage of the tube in 2.8%, malposition of the tube in 4.9%, suprachoroidal hemorrhage in 2.1%, cataract progression in 39.6% (phakic eyes), shallow anterior chamber in 9.2%, hyphaema in 28.9%, exposure of valve in 2.6%, exposure of tube in 9.3%, hypotony in 4.9% and conjunctival fibrosis in 41.5%. Despite the fact that Ahmed valve implant had suchlike results as other implants concerning the IOP control, complications rate due to hypotony or over filtration in the first days after the intervention are not that frequent as with other valve implants.

  15. Glaucoma Drainage Device Erosion Following Ptosis Surgery.

    Science.gov (United States)

    Bae, Steven S; Campbell, Robert J

    2017-09-01

    To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Case report. A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.

  16. Monitoring dynamics of aqueous humor in glaucoma

    International Nuclear Information System (INIS)

    Vyborny, P.; Hornova, J.

    1985-01-01

    Aqueous humor dynamics was observed in patients treated for glaucoma. Aqueous flow was measured using the radionuclide method of contact application of 22 NaCl and the detection of gamma radiation with external detectors. The sample of 184 eyes was divided into three groups: open-angle glaucoma with therapy, open-angle glaucoma without therapy and angle-closure glaucoma 47 eyes were used as controls. Changes were observed in 22 Na outflow half-time in dependence on the duration of the disease, therapy, intraocular pressUre and changes in the perimeter. The new technique has been fully proven in practice, is a contribution to the diagnosis of glaucoma and an indicator of the compensation of the disease. (author)

  17. Medical therapy cost considerations for glaucoma.

    Science.gov (United States)

    Fiscella, Richard G; Green, Amy; Patuszynski, Daniel H; Wilensky, Jacob

    2003-07-01

    To determine the calculated daily patient cost (cost minimization) of medical glaucoma therapy and review cost trends. Experimental, controlled, prospective study. The actual volume of various glaucoma medications or glaucoma medications with redesigned bottles was determined for most commercially available sizes of the tested products. The drops per milliliter based on the actual volume and the daily costs of the dosage schedules recommended by the manufacturers were compared. The cost of each bottle of medication was determined from the average wholesale price (AWP) in the United States. A comparison to 1999 prices where applicable will be analyzed to review costing trends. The generic timolol products (range, US dollars 0.38-US dollars 0.46 per day) were similar on a cost per day basis vs Betimol (Santen, Napa Valley, California, USA), Optipranolol (Bausch and Lomb Pharmaceuticals, Tampa, Florida, USA) and Timoptic (Merck, West Point, Pennsylvania, USA). Their percentage cost increase ranged from 5% to 22% since 1999, except for generic timolol XE gel-forming solution (48%). Betagan (Allergan, Irvine, California, USA), Betoptic S (Alcon Laboratories, Fort Worth, Texas, USA), and Ocupress (Novartis, Duluth, Georgia, USA) ranged from US dollars 0.88 to US dollars 1.11 per day, and their percentage cost increase ranged from 33% to 53%. Some brand-only products have raised their AWPs a greater percentage, including Betoptic S (37%), Iopidine (Alcon, Fort Worth, Texas, USA) (50%), Ocupress (Novartis Ophthalmics, Duluth, Georgia, USA) (53%), and Pilopine gel (Alcon, Fort Worth, Texas, USA) (32%). The mean cost per day for the topical carbonic anhydrase inhibitors Azopt (Alcon Laboratories; US dollars 1.33 per day) and Trusopt (Merck; US dollars 1.05 per day) differed from 1999 when prices were almost identical. Cosopt (Merck; timolol 0.5% plus dorzolamide 2%, US dollars 1.04 per day) was less than the cost of separate bottles of a topical carbonic anhydrase inhibitor

  18. Driving patterns in older adults with glaucoma.

    Science.gov (United States)

    van Landingham, Suzanne W; Hochberg, Chad; Massof, Robert W; Chan, Emilie; Friedman, David S; Ramulu, Pradeep Y

    2013-02-21

    The ability to drive is important for ensuring quality of life for many older adults. Glaucoma is prevalent in this age group and may affect driving. The purpose of this study is to determine if glaucoma and glaucomatous visual field (VF) loss are associated with driving cessation, limitations, and deference to another driver in older adults. Cross-sectional study. Eighty-one glaucoma subjects and 58 glaucoma suspect controls between age 60 and 80 reported if they had ceased driving, limited their driving in various ways, or preferred another to drive. Twenty-three percent of glaucoma subjects and 6.9% of suspects had ceased driving (p = 0.01). Glaucoma subjects also had more driving limitations than suspects (2.0 vs. 1.1, p = 0.007). In multivariable models, driving cessation was more likely for glaucoma subjects as compared to suspects (OR = 4.0; 95% CI = 1.1-14.7; p = 0.03). The odds of driving cessation doubled with each 5 decibel (dB) decrement in the better-eye VF mean deviation (MD) (OR = 2.0; 95% CI = 1.4-2.9; p driving limitations (OR = 4.7; 95% CI = 1.3-16.8; p = 0.02). The likelihood of reporting more limitations increased with the VF loss severity (OR = 1.6 per 5 dB decrement in the better-eye VF MD; 95% CI = 1.1-2.4; p = 0.02). Neither glaucoma nor VF MD was associated with other driver preference (p > 0.1 for both). Glaucoma and glaucomatous VF loss are associated with greater likelihood of driving cessation and greater limitation of driving in the elderly. Further prospective study is merited to assess when and why people with glaucoma change their driving habits, and to determine if their observed self-regulation of driving is adequate to ensure safety.

  19. Scanning the macula for detecting glaucoma

    Directory of Open Access Journals (Sweden)

    Viquar U Begum

    2014-01-01

    Full Text Available Background: With the advent of spectral domain optical coherence tomography (SDOCT, there has been a renewed interest in macular region for detection of glaucoma. However, most macular SDOCT parameters currently are thickness parameters which evaluate thinning of the macular layers but do not quantify the extent of area over which the thinning has occurred. We therefore calculated a new macular parameter, "ganglion cell complex surface abnormality ratio (GCC SAR" that represented the surface area over which the macular thickness was decreased. Purpose: To evaluate the ability of SAR in detecting perimetric and preperimetric glaucoma. Design: Retrospective image analysis. Materials and Methods: 68 eyes with perimetric glaucoma, 62 eyes with preperimetric glaucoma and 165 control eyes underwent GCC imaging with SDOCT. SAR was calculated as the ratio of the abnormal to total area on the GCC significance map. Statistical Analysis: Diagnostic ability of SAR in glaucoma was compared against that of the standard parameters generated by the SDOCT software using area under receiver operating characteristic curves (AUC and sensitivities at fixed specificities. Results: AUC of SAR (0.91 was statistically significantly better than that of GCC average thickness (0.86, P = 0.001 and GCC global loss volume (GLV; 0.88, P = 0.01 in differentiating perimetric glaucoma from control eyes. In differentiating preperimetric glaucoma from control eyes, AUC of SAR (0.72 was comparable to that of GCC average thickness (0.70, P > 0.05 and GLV (0.72, P > 0.05. Sensitivities at specificities of 80% and 95% of SAR were comparable (P > 0.05 for all comparisons to that of GCC average thickness and GLV in diagnosing perimetric and preperimetric glaucoma. Conclusion: GCC SAR had a better ability to diagnose perimetric glaucoma compared to the SDOCT software provided global GCC parameters. However, in diagnosing preperimetric glaucoma, the ability of SAR was similar to that of

  20. The Ahmed Glaucoma Valve in Refractory Glaucoma: Experiences in Southwest Ethiopia.

    Science.gov (United States)

    Gessesse, Girum W

    2015-07-01

    The management of refractory glaucoma is a challenging task for any glaucoma surgeon. This study is aimed to evaluate the efficacy of Ahmed Glaucoma Valve implantation in refractory glaucomas in South-West Ethiopia. A retrospective review was conducted on the charts of consecutive patients treated with Ahmed glaucoma valve implantation at Jimma University Specialized Hospital between August 2012 and August 2014. Success was defined as Intraocular Pressure (IOP) less than 22 mm Hg and greater than 5mm Hg at 6 months, with at least 30% reduction from baseline, without medical therapy (complete success) or either with or without medication (qualified successes). A total of 12 eyes of 11 patients were included. The mean age of patients was 40.7 (SD= 19.0) years; 63.6% of them were males. The main types of glaucoma were pseudoexfoliative (3 eyes), uveitic (2 eyes), chronic angle closure (2 eyes) and Juvenile Open Angle (JOAG) (2 eyes). The mean IOP was reduced from preoperative level (32.75±7.14 mmHg) to (15.75 ±4.35 mmHg) at six postoperative months, (PAhmed glaucoma valve implant appears to be effective and relatively safe for treating complicated glaucomas with success rate comparable with those reported from other studies. Ahmed glaucoma valve, refractory glaucoma, complications, Ethiopia.

  1. Outcomes of Ahmed Glaucoma Valve Revision in Pediatric Glaucoma.

    Science.gov (United States)

    Al-Omairi, Ahmed Mansour; Al Ameri, Aliah H; Al-Shahwan, Sami; Khan, Arif O; Al-Jadaan, Ibrahim; Mousa, Ahmed; Edward, Deepak P

    2017-11-01

    Encapsulation of the Ahmed glaucoma valve (AGV) plate is a common cause for postoperative elevation of intraocular pressure, especially in children. Many reports have described the outcomes of AGV revision in adults. However, the outcomes of AGV revision in children are poorly documented. The aim of this study was to determine the outcomes of AGV revision in children. Retrospective cross-sectional study. A retrospective chart review of patients less than 15 years of age who underwent AGV revision with a minimum postoperative follow-up of 6 months was conducted. Outcome measures included reduction in intraocular pressure from baseline, survival analysis, and reduction in the number of antiglaucoma medications. Postoperative complications were also noted. Complete success was defined as an IOP of 21 mm Hg or less without medications, while qualified success was defined as having an IOP of 21 mm Hg or less with medications. A total of 44 eyes met the inclusion criteria. Primary congenital glaucoma was present in 39 eyes (88.6%), aphakic glaucoma in 4 eyes (9.1%), and Peters anomaly-associated glaucoma in 1 eye (2.3%). The mean number of previous surgeries was 1.4, and the mean age was 6.7 years (range, 1.9-13 years) with a median follow-up of 12 months (range, 6-24 months). The IOP was reduced from a preoperative mean of 30.4 (± 10.3) to 24.9 (± 10.6) mm Hg at 6 months postoperatively. Kaplan-Meier analysis showed that the complete success rate at 1 month was 100% followed by a rapid decline at 6 months to 38.6%, 27.7% at 1 year, and 5.5% at 2 years. Qualified success rate was 100% at 1 month followed by a 6-month and 1-year survival rate of approximately 50% and a 2-year survival rate of approximately 16%. The median survival time was 14 months. No specific risk factors for failure were identified. Visual acuity remained unchanged following revision. The most common complication was recurrence of encapsulation with elevated IOP (15.9%). Other

  2. Efficacy of intravitreal ranibizumab combined with Ahmed glaucoma valve implantation for the treatment of neovascular glaucoma.

    Science.gov (United States)

    Tang, Min; Fu, Yang; Wang, Ying; Zheng, Zhi; Fan, Ying; Sun, Xiaodong; Xu, Xun

    2016-01-09

    Neovascular glaucoma is a refractive glaucoma. Recently, anti-VEGF factors have been used alone or in combination for the treatment of neovascular glaucoma. However, the medium- and long-term efficacy of such drugs remains to be evaluated. This study was to determine the efficacy of intravitreal ranibizumab combined with Ahmed glaucoma valve implantation for the treatment of neovascular glaucoma. In this prospective non-randomized study, 43 neovascular glaucoma patients (43 eyes) were assigned to receive either 0.5 mg intravitreal ranibizumab for three to 14 days before Ahmed glaucoma valve implantation (injection group, n = 21) or Ahmed glaucoma valve implantation alone (control group, n = 22). The patients were followed up for six to 12 months. Differences in surgical success rate, intraocular pressure, best corrected visual acuity, anti-glaucoma medications and postoperative complications were compared between the two groups. Surgical success was defined as IOP > = 6 mm Hg and glaucoma medications, and without severe complications or reoperation. Of the 43 patients, 40 completed the 6-month follow-up and 37 completed the 1-year follow-up. Success rate was 73.7% vs. 71.4% at six months and 72.2% vs. 68.4% at 12 months in the injection group and the control group respectively. No significant difference was noted between the two groups (six months: P = 0.87, 12 months: P = 1.00). There were no significant differences in the two groups with respect to intraocular pressure, best corrected visual acuity, anti-glaucoma medications or postoperative complications at six months or 12 months. Single intravitreal ranibizumab (0.5 mg) before surgery has no significant effect on the medium- or long-term outcomes of neovascular glaucoma treated with Ahmed glaucoma valve implantation. Chinese Clinical Trial Registry ( ChiCTR-OOC-14005709, Trial registration date: 2014-12-01).

  3. Optimization of suspensions filtration with compressible cake

    Directory of Open Access Journals (Sweden)

    Janacova Dagmar

    2016-01-01

    Full Text Available In this paper there is described filtering process for separating reaction mixture after enzymatic hydrolysis to process the chromium tanning waste. Filtration of this mixture is very complicated because it is case of mixture filtration with compressible cake. Successful process strongly depends on mathematical describing of filtration, calculating optimal values of pressure difference, specific resistant of filtration cake and temperature maintenance which is connected with viscosity change. The mathematic model of filtration with compressible cake we verified in laboratory conditions on special filtration device developed on our department.

  4. Filtration set for gaseous fluids

    International Nuclear Information System (INIS)

    Lebrun, B.; Couvrat-Desvergnes, A.

    1988-01-01

    This filtration set is made by a cylindrical vessel containing upstairs to downstairs, the gas inlet, a sealed floor for man inspection, a horizontal granular filter bed, a linen with a porosity inferior to the granulometry of the filter bed, a light support layer of material of larger granulometry, gas permeable tubes and an annular collector connecting the tubes to the outlet [fr

  5. Some observations on air filtration

    NARCIS (Netherlands)

    Kluyver, A.J.; Visser, J.

    1950-01-01

    1. A method has been developed for testing the filtration efficiency of some filter materials. For each of the materials investigated — cotton wool, stillite and carbon — a suitable filter has been devised. 2. The filtered air was analyzed as to its germ content with the aid of a set of 3 capillary

  6. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  7. Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

    Science.gov (United States)

    Greenlee, Emily C; Kwon, Young H

    2008-06-01

    Glaucoma after penetrating keratoplasty is a frequently observed post-operative complication and is a risk factor for graft failure. Penetrating keratoplasty performed for aphakic and pseudophakic bullous keratopathy and inflammatory conditions are more likely to cause postoperative glaucoma compared with keratoconus and Fuchs' endothelial dystrophy. The intraocular pressure elevation may occur immediately after surgery or in the early to late postoperative period. Early postoperative causes of glaucoma include pre-existing glaucoma, retained viscoelastic, hyphema, inflammation, pupillary block, aqueous misdirection, or suprachoroidal hemorrhage. Late causes include pre-existing glaucoma, angle-closure glaucoma, ghost cell glaucoma, suprachoroidal hemorrhage, and steroid-induced glaucoma. Determining the cause of IOP elevation can help guide therapeutic intervention. Treatments for refractory glaucoma include topical anti-glaucoma medications such as beta-adrenergic blockers. Topical carbonic anhydrase inhibitors, miotic agents, adrenergic agonists, and prostaglandin analogs should be used with caution in the post-keratoplasty patient, because of the possibility of corneal decompensation, cystoid macular edema, or persistent inflammation. Various glaucoma surgical treatments have reported success in post-keratoplasty glaucoma. Trabeculectomy with mitomycin C can be successful in controlling IOP without the corneal toxicity noted with 5-fluorouracil. Glaucoma drainage devices have successfully controlled intraocular pressure in postkeratoplasty glaucoma; this is, however, associated with increased risk of graft failure. Placement of the tube through the pars plana may improve graft success compared with implantation within the anterior chamber. In addition, cyclophotocoagulation remains a useful procedure for eyes that have refractory glaucoma despite multiple surgical interventions.

  8. Mitigation of radon and thoron decay products by filtration

    International Nuclear Information System (INIS)

    Wang Jin; Meisenberg, Oliver; Chen Yongheng; Karg, Erwin; Tschiersch, Jochen

    2011-01-01

    Inhalation of indoor radon ( 222 Rn) and thoron ( 220 Rn) decay products is the most important source of exposure to ionizing radiation for the human respiratory tract. Decreasing ventilation rates due to energy saving reasons in new buildings suggest additional active mitigation techniques to reduce the exposure in homes with high radon and thoron concentrations but poor ventilation. Filtration techniques with HEPA filters and simple surgical mask material have been tested for their potential to reduce the indoor exposure in terms of the total effective dose for mixed radon and thoron indoor atmospheres. The tests were performed inside an experimental room providing stable conditions. Filtration (at filtration rates of 0.2 h -1 and larger) removes attached radon and thoron decay products effectively but indoor aerosol as well. Therefore the concentration of unattached decay products (which have a higher dose coefficient) may increase. The decrease of the attached decay product concentrations could be theoretically described by a slowly decreasing exponential process. For attached radon decay products, it exhibited a faster but weaker removal process compared to attached thoron decay products (- 70% for attached radon decay products and - 80% for attached thoron decay products at a filtration rate of 0.5 h -1 with an HEPA filter). The concentration of unattached thoron decay products increased distinctly during the filtration process (+ 300%) while that of unattached radon decay products rose only slightly though at a much higher level (+ 17%). In the theoretical description these observed differences could be attributed to the different half-lives of the nuclides. Considering both effects, reduced attached and increased unattached decay product concentrations, filtration could significantly decrease the total effective dose from thoron whereas the overall effect on radon dose is small. A permanent filtration is recommended because of the slow decrease of the

  9. Relation between Glaucoma and Sensorineural Hearing Loss

    Directory of Open Access Journals (Sweden)

    A Mollasadeghi

    2008-01-01

    Full Text Available Introduction: Glaucoma is one of the leading causes of blindness throughout the world. Some studies have suggested a relationship between glaucoma and sensorineural hearing loss, while others have found no evidence of an association. We performed a study to determine whether there is a significant difference in hearing of patients with glaucoma and a match control population. Methods: In this cross-sectional study, from February, 2005 till April, 2006, 44 patients with glaucoma were studied. The age range was between 15 to 60 years. After taking a complete medical history, those suffering from presbycusis, history of exposure to ototoxic drugs and substances and history of ear surgery were excluded from the study. All of the patients were cases of open-angle glaucoma, and were surveyed separately for normal-pressure glaucoma. Then complete audiometric tests (PTA, SDS, SRT, Impedance were conducted for all of them, and the results compared with a control group. Results: There was no statistically significant difference between the case group and control group in PTA, SDS, and SRT, except for Normal Tension Glaucoma (NTG. There wasn't any statistically significant difference between two groups with respect to age, gender, and history of diseases. In the NTG group, significant difference was seen only in high frequencies. Conclusion: As mentioned, there was a statistically significant difference between NTG group and control group. It is therefore recommended to conduct complete audiometric tests and histopathologic examinations in this group for early detection of hearing loss and application of rehabilitative measures.

  10. Glaucoma as a Metabolic Optic Neuropathy: Making the Case for Nicotinamide Treatment in Glaucoma.

    Science.gov (United States)

    Williams, Pete A; Harder, Jeffrey M; John, Simon W M

    2017-12-01

    Mitochondrial dysfunction may be an important, if not essential, component of human glaucoma. Using transcriptomics followed by molecular and neurobiological techniques, we have recently demonstrated that mitochondrial dysfunction within retinal ganglion cells is an early feature in the DBA/2J mouse model of inherited glaucoma. Guided by these findings, we discovered that the retinal level of nicotinamide adenine dinucleotide (NAD, a key molecule for mitochondrial health) declines in an age-dependent manner. We hypothesized that this decline in NAD renders retinal ganglion cells susceptible to damage during periods of elevated intraocular pressure. To replete NAD levels in this glaucoma, we administered nicotinamide (the amide of vitamin B3). At the lowest dose tested, nicotinamide robustly protected from glaucoma (~70% of eyes had no detectable glaucomatous neurodegeneration). At this dose, nicotinamide had no influence on intraocular pressure and so its effect was neuroprotective. At the highest dose tested, 93% of eyes had no detectable glaucoma. This represents a ~10-fold decrease in the risk of developing glaucoma. At this dose, intraocular pressure still became elevated but there was a reduction in the degree of elevation showing an additional benefit. Thus, nicotinamide is unexpectedly potent at preventing this glaucoma and is an attractive option for glaucoma therapeutics. Our findings demonstrate the promise for both preventing and treating glaucoma by interventions that bolster metabolism during increasing age and during periods of elevated intraocular pressure. Nicotinamide prevents age-related declines in NAD (a decline that occurs in different genetic contexts and species). NAD precursors are reported to protect from a variety of neurodegenerative conditions. Thus, nicotinamide may provide a much needed neuroprotective treatment against human glaucoma. This manuscript summarizes human data implicating mitochondria in glaucoma, and argues for studies to

  11. Glaucoma evolution in patients with diabetes.

    Science.gov (United States)

    Apreutesei, Nicoleta Anton; Chiselita, D; Motas, O I

    2014-01-01

    Glaucoma and diabetes are two chronic diseases with a long suspected pathogenic relationship. Screening for glaucoma in patients with diabetes. A retrospective study on 92 eyes from 46 patients with primitive open angle glaucoma (POAG) (normal and hypertensive) and intraocular hypertension (OHT) receiving medication and/or surgery associated with diabetes mellitus (DM) (type I, type II, mixed) is presented. Participants were divided into two groups as following: 16 eyes with glaucoma and diabetic retinopathy changes (group 1) and 76 eyes with glaucoma and without diabetic retinopathy changes (group 2). The following parameters were analysed: ocular pressure (Goldmann aplanotonometry), perimeter development (computerized perimetry) and fundus condition (absence, presence or progression of diabetic retinopathy). In patients with glaucoma and diabetic retinopathy (8 patients) we found a mean difference between treated intraocular pressure (IOP) and IOP last untreated control of 4.95 mmHg; a depreciation of the MD by 4.18 dB and an average number of glaucoma medications used of 0.889 +/- 1.054. Predominant changes in proliferative diabetic retinopathy were mild. In patients with glaucoma in the absence of diabetic retinopathy, the average difference between untreated IOP and IOP under treatment at the last check-up was 1.63 mmHg, the MD depreciation was by 0.65 dB and the average number of glaucoma medications used was 0.795 +/- 0.978. No statistically significant differences in terms of initial and final pressure were found. No statistically significant differences in the evolution of changes in perimeter between the two groups were observed. The presence of non-proliferating diabetic retinopathy influenced (only marginally statistically) the glaucomatous disease progression. Large comparative prospective studies are needed for the long-term follow up.

  12. Filtrations of free groups as intersections

    OpenAIRE

    Efrat, Ido

    2013-01-01

    For several natural filtrations of a free group S we express the n-th term of the filtration as the intersection of all kernels of homomorphisms from S to certain groups of upper-triangular unipotent matrices. This generalizes a classical result of Grun for the lower central filtration. In particular, we do this for the n-th term in the lower p-central filtration of S.

  13. Simulations of Microbial-Enhanced Oil Recovery: Adsorption and Filtration

    DEFF Research Database (Denmark)

    Nielsen, Sidsel Marie; Nesterov, Igor; Shapiro, Alexander

    2014-01-01

    In the context of microbial-enhanced oil recovery (MEOR) with injection of surfactant-producing bacteria into the reservoir, different types of bacteria attachment and growth scenarios are studied using a 1D simulator. The irreversible bacteria attachment due to filtration similar to the deep bed...... applied to filtration model provides formation of two oil banks during recovery. This feature is not reproduced by application of REA model or DBF with growth in attached phase. This makes it possible to select a right model based on the qualitative analysis of the experimental data. A criterion...... is introduced to study the process efficiency: the dimensionless time at which average recovery between pure water injection and maximum surfactant effect is reached. This characteristic recovery period (CRP) was studied as a function of the different MEOR parameters such as bacterial activity, filtration...

  14. Importance of intraocular pressure in glaucoma

    Science.gov (United States)

    Joos, Karen M.

    1999-06-01

    Glaucoma results in permanent vision loss and affects the peripheral vision initially. It is presented in 22.5 million people worldwide and is the 3rd cause of blindness. Present tonometers are not ideal for intraocular pressure measurements in all eyes. Of concern, PRK and LASIK may result in lower intraocular pressure readings. A challenges now exists for the development of a tonometer which can easily compensate for corneas with many parameters to avoid a future increase in normal-tension glaucoma or glaucoma which is advanced.

  15. Coincidence of retinitis pigmentosa and pseudoexfoliative glaucoma

    Directory of Open Access Journals (Sweden)

    Božić Marija

    2017-01-01

    Full Text Available Introduction. This is an observational case report presenting retinitis pigmentosa associated with pseudoexfoliative glaucoma. Case outline. A 69-year-old man presented with retinitis pigmentosa. On examination, pseudoexfoliative material was detected on anterior segment structures, and intraocular pressure was 26 mmHg in the right and 24 mmHg in the left eye. The patient was commenced on topical antiglaucomatous therapy (timolol + dorzolamide twice daily, latanoprost once in the evening to both eyes. Conclusion. To the best of our knowledge, this is the first reported case of retinitis pigmentosa associated with pseudoexfoliative glaucoma. Although rare, retinitis pigmentosa and glaucoma can occur in the same eye.

  16. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  17. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  18. Safety and efficacy of a low-cost glaucoma drainage device for refractory childhood glaucoma.

    Science.gov (United States)

    Kaushik, Sushmita; Kataria, Pankaj; Raj, Srishti; Pandav, Surinder Singh; Ram, Jagat

    2017-12-01

    To evaluate the safety and efficacy of a low-cost glaucoma drainage device (GDD), Aurolab aqueous drainage implant (AADI), similar in design to the Baerveldt glaucoma implant (BGI), in refractory childhood glaucoma. This prospective interventional study was conducted in a tertiary care postgraduate teaching institute. Children aged glaucoma valve implant in children. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  20. Spontaneous water filtration of bio-inspired membrane

    Science.gov (United States)

    Kim, Kiwoong; Kim, Hyejeong; Lee, Sang Joon

    2016-11-01

    Water is one of the most important elements for plants, because it is essential for various metabolic activities. Thus, water management systems of vascular plants, such as water collection and water filtration have been optimized through a long history. In this view point, bio-inspired technologies can be developed by mimicking the nature's strategies for the survival of the fittest. However, most of the underlying biophysical features of the optimized water management systems remain unsolved In this study, the biophysical characteristics of water filtration phenomena in the roots of mangrove are experimentally investigated. To understand water-filtration features of the mangrove, the morphological structures of its roots are analyzed. The electrokinetic properties of the root surface are also examined. Based on the quantitatively analyzed information, filtration of sodium ions in the roots are visualized. Motivated by this mechanism, spontaneous desalination mechanism in the root of mangrove is proposed by combining the electrokinetics and hydrodynamic transportation of ions. This study would be helpful for understanding the water-filtration mechanism of the roots of mangrove and developing a new bio-inspired desalination technology. This research was financially supported by the National Research Foundation (NRF) of Korea (Contract Grant Number: 2008-0061991).

  1. Design, Fabrication, and In Vitro Testing of an Anti-biofouling Glaucoma Micro-shunt.

    Science.gov (United States)

    Harake, Ryan S; Ding, Yuzhe; Brown, J David; Pan, Tingrui

    2015-10-01

    Glaucoma, one of the leading causes of irreversible blindness, is a progressive neurodegenerative disease. Chronic elevated intraocular pressure (IOP), a prime risk factor for glaucoma, can be treated by aqueous shunts, implantable devices, which reduce IOP in glaucoma patients by providing alternative aqueous outflow pathways. Although initially effective at delaying glaucoma progression, contemporary aqueous shunts often lead to numerous complications and only 50% of implanted devices remain functional after 5 years. In this work, we introduce a novel micro-device which provides an innovative platform for IOP reduction in glaucoma patients. The device design features an array of parallel micro-channels to provide precision aqueous outflow resistance control. Additionally, the device's microfluidic channels are composed of a unique combination of polyethylene glycol materials in order to provide enhanced biocompatibility and resistance to problematic channel clogging from biofouling of aqueous proteins. The microfabrication process employed to produce the devices results in additional advantages such as enhanced device uniformity and increased manufacturing throughput. Surface characterization experimental results show the device's surfaces exhibit significantly less non-specific protein adsorption compared to traditional implant materials. Results of in vitro flow experiments verify the device's ability to provide aqueous resistance control, continuous long-term stability through 10-day protein flow testing, and safety from risk of infection due to bacterial ingression.

  2. GENDER AND AGE FEATURES OF GLAUCOMA

    Directory of Open Access Journals (Sweden)

    O. V. Makarenk

    2014-02-01

    Full Text Available Today, the definition “glaucoma” combines a number of eye pathologies that lead to irreversible blindness, and therefore is difficult disabling disease. Glaucoma occurs in people of working age, so this problem is not only medical, but also social, because it causes disability in substantial economic costs not only for individual patients, but also for the whole country – patients become unable to work. Gender features of glaucoma are also contradictory. In European literature the basic idea is that men are more likely to suffer from glaucoma than women. Such studies have not been conducted in the Podillya region of Ukraine, that makes impossible to design a reliable global data to estimate the prevalence of glaucoma in different age groups for persons living in Vinnitsa region. Therefore, the aim of the study was a retrospective analysis of medical records of patients in Eye Microsurgery Department of Vinnitsa Regional Clinical Hospital for the period 2008-2012 years for determining the gender and age characteristics. Materials and methods 1418 patients with primary open-angle glaucoma (841 men and 577 women aged 14 to 92 years (mean age 67,12 ± 7,64, which were treated in the Eye Microsurgery Department, took part in the study. For the purpose of the study they were divided into two groups: I – male patients with glaucoma, II – female patients with glaucoma. Each group was divided into 7 subgroups according to the ontogenesis scheme: A – teens, B – youth, C – I adulthood age, D – II adulthood age, E – elderly age, F – senily age and G – centenarians. Thus was allocated 12 research groups. Results The structure of the incidence of glaucoma is 59.31% in men and 40.69% in women. Incidence of glaucoma is highest in the IE group and is 34.98%. The group IIE incidence is lower – 35.32%. In the group D the incidence of glaucoma among men and women was very different (13.89% and 2.89%, respectively. It should also be noted

  3. Demonstration of creep during filtration

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Bugge, Thomas Vistisen; Kirchheiner, Anders Løvenbalk

    The classical filtration theory assumes a unique relationship between the local filter cake porosity and the local effective pressure. For a number of compressible materials, it has however been observed that during the consolidation stage this may not be the case. It has been found...... that the production of filtrate also depends on the characteristic time for the filter cake solids to deform. This is formulated in the Terzaghi-Voigt model in which a secondary consolidation is introduced. The secondary consolidation may be visualized by plots of the relative cake deformation (U) v.s. the square...... root of time. Even more clearly it is demonstrated by plotting the liquid pressure at the cake piston interface v.s. the relative deformation (to be shown). The phenomenon of a secondary consolidation processes is in short called creep. Provided that the secondary consolidation rate is of the same...

  4. Properties of plastic filtration material

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1988-01-01

    Discusses properties of filters made of thermoplastic granulated material. The granulated plastic has a specific density of 10.3-10.6 kN/m/sup 3/ and a bulk density of about 6 kN/m/sup 3/. Its chemical resistance to acids, bases and salts is high but is it soluble in organic solvents. Filters made of this material are characterized by a porosity coefficient of 36.5% and a bulk density of 5.7-6.8 kN/m/sup 3/. Physical and mechanical properties of filter samples made of thermoplastic granulated material (50x50x50 mm) were investigated under laboratory conditions. Compression strength and influencing factors were analyzed (ambient temperature, manufacturing technology). Tests show that this filtration material developed by Poltegor is superior to other filtration materials used in Poland.

  5. Pigment dispersion syndrome and pigmentary glaucoma: a review and update.

    Science.gov (United States)

    Scuderi, Gianluca; Contestabile, Maria Teresa; Scuderi, Luca; Librando, Aloisa; Fenicia, Vito; Rahimi, Siavash

    2018-05-02

    Potential factors influencing stereopsis were investigated in patients with both refractive accommodative esotropia (RAE) and amblyopia. Pigment dispersion syndrome (PDS) is a condition where anomalous iridozonular contact leads to pigment dispersion throughout the anterior segment and the released pigment is abnormally deposited on various ocular structures. The clinical presentation of PDS is defined by the presence of pigmented cells on the corneal endothelium, an increase of pigmentation of the trabecular meshwork, and mid-periphery transillumination defects of the iris. This syndrome, more common in myopes, is usually bilateral and can be associated with ocular hypertension or glaucoma. Secondary open-angle pigmentary glaucoma (PG) can develop due to reduction of the outflow of aqueous humour and consequent increase in intraocular pressure leading to glaucomatous optic neuropathy. Diagnosis of PG is commonly between 40 and 50 years of age, occurring more frequently in men. The advent of ultrasound biomicroscopy and anterior segment optical coherence tomography has contributed to enhancing our knowledge on the condition. Typical alterations of the anterior segment are the posterior insertion of the iris and iris concavity. Treatment of PG should be initiated early to hinder disease progression, glaucomatous damage, and vision loss. Management is based on medical therapy, laser iridotomy, selective laser trabeculoplasty, and filtration procedures. The differential diagnosis of PDS with other disorders can be challenging and awareness of the condition together with meticulous ophthalmologic examination allows early diagnosis followed by appropriate management strategies. The present review is a comprehensive report on the clinical characteristics, pathogenesis, current management, and status quo of PDS and PG.

  6. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  7. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery.

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  8. Cyclodialysis ab interno as a surgical approach to intractable glaucoma.

    Science.gov (United States)

    Jordan, Jens F; Dietlein, Thomas S; Dinslage, Sven; Lüke, Christoph; Konen, Walter; Krieglstein, Günter K

    2007-08-01

    In glaucoma filtration surgery, the problem of subconjunctival scarring has still not been satisfactorily solved. Suprachoroidal drainage of aqueous humour offers a promising, alternative option for intractable glaucoma. We here present a clinical study on the surgical approach of gonioscopic cyclodialysis ab interno. Twenty-eight eyes of 20 patients with intractable glaucoma were included in this prospective, consecutive, case-control study. The eyes had had a mean of 4.4 +/- 2.4 previous antiglaucomatous interventions. Baseline intraocular pressure (IOP) was 34.3 +/- 10.5 mmHg despite maximum therapy. Under gonioscopic control, cyclodialysis ab interno was performed over two clock times to gain access to the suprachoroidal space. No additional trabecular meshwork surgery was performed. Success was defined as a lowering of IOP to below 21 mmHg without the need for further medication or intervention. Mean postoperative IOP was 14.6 +/- 12.4 mmHg. Mean follow-up (FU) for all eyes was 121.8 days. After a mean of 60 days, 21 eyes (75%) needed further surgical intervention. Qualified success was seen in four eyes (14.3%), with a mean FU of 383.6 days. Three eyes (10.7%) showed absolute success after a mean FU period of 202.7 days. In our series, we obtained the best results for phakic eyes, followed by pseudophakic and aphakic eyes. The results of this study do not provide convincing evidence of the functional efficacy of cyclodialysis ab interno. Nevertheless, the technique is easy to perform and offers safe and atraumatic access to the resorptive capability of the choroid. Conjunctival manipulation is avoided. Contrary to reports in the current literature, in our series, the best results were obtained for phakic eyes, though the small number of eyes included does not allow reliable statistics. Further studies will need to focus on the use of different space-retaining substances or a widening of the cyclodialysis cleft to improve surgical outcome.

  9. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  10. Management of exfoliative glaucoma: challenges and solutions.

    Science.gov (United States)

    Holló, Gábor; Katsanos, Andreas; Konstas, Anastasios Gp

    2015-01-01

    Exfoliative glaucoma is the most common type of secondary open-angle glaucoma worldwide. It is characterized by high intraocular pressure (IOP) and worse 24-hour IOP characteristics. In order to minimize progression, treatment of exfoliative glaucoma has to provide a low long-term mean IOP and good 24-hour IOP control. To achieve these goals, fixed-dose combination eye drops, argon and selective laser trabeculoplasty, and various forms of surgery (trabeculectomy, deep sclerectomy, viscocanalostomy, ab interno trabeculotomy, trabecular aspiration, and cataract surgery) all need to be considered during the long-term management of the disease. Since exfoliative glaucoma is a disease of the elderly, and is frequently associated with systemic vascular disease, interdisciplinary consultations are of great clinical importance. These management aspects and the current medical, laser, and surgical results are covered in this review, with a special focus on the needs of the general ophthalmologist.

  11. The interrelation between hypothyroidism and glaucoma

    DEFF Research Database (Denmark)

    Thvilum, Marianne; Hjelm Brandt Kristensen, Frans; Brix, Thomas Heiberg

    2017-01-01

    Data on the association between hypothyroidism and glaucoma are conflicting. We sought to shed light on this by conducting a critical review and meta-analyses. The meta-analyses were conducted in adherence with the widely accepted MOOSE guidelines. Using the Medical Subject Heading (MeSH) terms......: hypothyroidism, myxoedema and glaucoma or intraocular pressure, case-control studies, cohort studies and cross-sectional studies were identified (PubMed) and reviewed. Using meta-analysis, the relative risk (RR) of coexistence of glaucoma and hypothyroidism was calculated. Based on the literature search......, thirteen studies fulfilled the inclusion criteria and could be categorized into two groups based on the exposure. The designs of the studies varied considerably, and there was heterogeneity related to lack of power, weak phenotype classifications and length of follow-up. Eight studies had glaucoma (5757...

  12. Glaucoma detection with damato multifixation campimetry online

    DEFF Research Database (Denmark)

    Olsen, Ane Sophie; Alberti, M.; Serup, L.

    2016-01-01

    to define abnormality, and these were evaluated using the Glaucoma Staging System as gold standard. Receiver operating characteristic (ROC) curves and area under the ROC (AUC) were calculated. Results AUCs from 15 algorithms ranged from 0.79 to 0.90. The most promising algorithm combined results from two...... successive DMCO STANDARD tests. The sensitivity was highly dependent on the severity of glaucoma. Hence, for eyes with mild, moderate, advanced, and severe glaucoma, the DMCO test demonstrated a sensitivity of 11.8, 71.4, 100, and 100%, respectively. The specificity was as high as 98.1%. Median duration per...... eye to complete the DMCO STANDARD test was 86 s for the control group and 125 s in participants with glaucoma. Conclusions DMCO shows promise as a free-of-charge online tool to identify glaucomatous visual field defects in a preselected population. Ongoing studies are evaluating the use of DMCO...

  13. Antihypertensive medication postpones the onset of glaucoma

    DEFF Research Database (Denmark)

    Horwitz, Anna; Klemp, Marc; Jeppesen, Jørgen

    2017-01-01

    The aim was to investigate the impact of antihypertensive medication on the onset of glaucoma. Data from the complete Danish population between 40 and 95 years of age were used in the period from 1996 to 2012, covering >2.6 million individuals. The National Danish Registry of Medicinal Products...... Statistics was used to identify all claimed prescriptions for glaucoma medication and antihypertensive drugs. We first investigated basic correlations in the data and found that patients treated with antihypertensive medication, at any time during the study period, had a significantly higher overall relative...... risk (RR) of glaucoma, even when controlling for age and sex (with a RR of 1.31 and Pglaucoma. To investigate the causal effect of antihypertensive treatment on the onset of treatment for glaucoma, we used...

  14. The role of inflammation in the pathogenesis of glaucoma

    DEFF Research Database (Denmark)

    Vohra, Rupali; Tsai, James C; Kolko, Miriam

    2013-01-01

    Glaucoma is an ocular disorder characterized by the progressive loss of retinal ganglion cells (RGC) and their axons. There are various hypotheses concerning the cause of RGC death. Previously, glaucoma was defined by high intraocular pressure (IOP); during the past decade, however, glaucoma...... specialists have acknowledged that elevated IOP is the most important risk factor for glaucoma, but does not define the disease. Other factors such as genetics, blood flow, and excitotoxicity are suggested as potential causal factors for progressive RGC death observed in glaucoma. We review recent studies...... elucidating a possible role of low-grade inflammation as a causal factor in the pathogenesis of glaucoma....

  15. The use of Ahmed glaucoma valve in the management of pediatric glaucoma.

    Science.gov (United States)

    Balekudaru, Shantha; Vadalkar, Juhie; George, Ronnie; Vijaya, Lingam

    2014-08-01

    To assess the intraocular pressure control (IOP), changes in visual acuity, complications, reoperation rates and risk factors for failure following Ahmed glaucoma valve implantation in pediatric eyes with glaucoma. The medical records of consecutive patients with glaucoma who underwent Ahmed glaucoma valve implantation from January 2000 to December 2009) were retrospectively reviewed. Only one eye of each patient was included. Subgroup analysis was performed in three groups; group 1 included phakic eyes with primary congenital glaucoma, juvenile open-angle glaucoma, or glaucoma associated with ocular anomalies; group 2 included eyes with glaucoma in aphakia or pseudophakia; group 3 included eyes with other diagnoses. A successful outcome was defined as final IOP between 6 mm Hg and 18 mm Hg without loss of light perception or reoperation for glaucoma. A total of 71 eyes in 71 patients: 15 (21%) in group 1, 47 (66%) in group 2, and 9 (13%) in group 3 were included Successful IOP control was achieved in 44 eyes of 44 patients (62%). Cumulative probabilities of success by Kaplan-Meier analysis at 12 and 24 months was 97% and 80% for the entire group, 100% and 82% for group 1, 95% and 86% for group 2, and 90% and 42% for group 3. Reoperation was necessary for 18 patients (25%), either for tube-related complications or for IOP control. The only significant risk factor for failure was the category of diagnosis (P = 0.029). Ahmed glaucoma valve implantation is an option in the management of pediatric glaucoma; however, reoperations for tube related complications or for persistent elevated IOP is frequently needed. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  16. Relation Between Filtration and Soil Consolidation Theories

    Directory of Open Access Journals (Sweden)

    Strzelecki Tomasz

    2015-03-01

    Full Text Available This paper presents a different, than commonly used, form of equations describing the filtration of a viscous compressible fluid through a porous medium in isothermal conditions. This mathematical model is compared with the liquid flow equations used in the theory of consolidation. It is shown that the current commonly used filtration model representation significantly differs from the filtration process representation in Biot’s and Terzaghi’s soil consolidation models, which has a bearing on the use of the methods of determining the filtration coefficient on the basis of oedometer test results. The present analysis of the filtration theory equations should help interpret effective parameters of the non-steady filtration model. Moreover, equations for the flow of a gas through a porous medium and an interpretation of the filtration model effective parameters in this case are presented.

  17. The optic nerve head in glaucoma

    Directory of Open Access Journals (Sweden)

    Rupert RA Bourne

    2006-09-01

    Full Text Available ll types of glaucoma involve glaucomatous optic neuropathy. The key to detection and management of glaucoma is understanding how to examine the optic nerve head (ONH. This pictorial glossary addresses the following issues: how to examine the ONH; normal characteristics of the ONH; characteristics of a glaucomatous ONH; how to tell if the glaucomatous optic neuropathy is getting worse;‘pitfalls and pearls’.

  18. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    OpenAIRE

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical...

  19. Experiments on high efficiency aerosol filtration

    International Nuclear Information System (INIS)

    Mazzini, M.; Cuccuru, A.; Kunz, P.

    1977-01-01

    Research on high efficiency aerosol filtration by the Nuclear Engineering Institute of Pisa University and by CAMEN in collaboration with CNEN is outlined. HEPA filter efficiency was studied as a function of the type and size of the test aerosol, and as a function of flowrate (+-50% of the nominal value), air temperature (up to 70 0 C), relative humidity (up to 100%), and durability in a corrosive atmosphere (up to 140 hours in NaCl mist). In the selected experimental conditions these influences were appreciable but are not sufficient to be significant in industrial HEPA filter applications. Planned future research is outlined: measurement of the efficiency of two HEPA filters in series using a fixed particle size; dependence of the efficiency on air, temperatures up to 300-500 0 C; performance when subject to smoke from burning organic materials (natural rubber, neoprene, miscellaneous plastics). Such studies are relevant to possible accidental fires in a plutonium laboratory

  20. The role of matricellular proteins in glaucoma.

    LENUS (Irish Health Repository)

    Wallace, Deborah M

    2014-07-01

    Glaucoma is an optic neuropathy affecting approximately 60million people worldwide and is the second most common cause of irreversible blindness. Elevated intraocular pressure (IOP) is the main risk factor for developing glaucoma and is caused by impaired aqueous humor drainage through the trabecular meshwork (TM) and Schlemm\\'s canal (SC). In primary open angle glaucoma (POAG), this elevation in IOP in turn leads to deformation at the optic nerve head (ONH) specifically at the lamina cribrosa (LC) region where there is also a deposition of extracellular matrix (ECM) molecules such as collagen and fibronectin. Matricellular proteins are non-structural secreted glycoproteins that help cells communicate with their surrounding ECM. This family of proteins includes connective tissue growth factor (CTGF), also known as CCN2, thrombospondins (TSPs), secreted protein acidic and rich in cysteine (SPARC), periostin, osteonectin, and Tenascin-C and -X and other ECM proteins. All members appear to play a role in fibrosis and increased ECM deposition. Most are widely expressed in tissues particularly in the TM and ONH and deficiency of TSP1 and SPARC have been shown to lower IOP in mouse models of glaucoma through enhanced outflow facility. The role of these proteins in glaucoma is emerging as some have an association with the pathophysiology of the TM and LC regions and might therefore be potential targets for therapeutic intervention in glaucoma.

  1. Fluoride removal from water by nano filtration

    International Nuclear Information System (INIS)

    Bejaoui, Imen; Mnif, Amine; Hamrouni, Bechir

    2009-01-01

    As any oligo element, fluoride is necessary and beneficial for human health to low concentrations, but an excess amount of fluoride ions in drinking water has been known to cause undesirable effects, especially tooth and bones fluoro sis. The maximum acceptable concentration of fluoride in drinking water was fixed by the World Health Organization according to the climate in the range of 1 mg.L -1 to 1,2 mg.L -1 . Many methods have been used to remove fluoride from water such as precipitation, adsorption, electrocoagulation and membrane processes. Technologies using membrane processes are being used in many applications, particularly for brackish water desalination. Nano filtration seems to be the best process for a good selective defluorination of fluorinated waters. The main objective of this work was to investigate the retention of fluoride anions by nano filtration. The first part of this study deals with the characterisation of the NF HL2514TF membrane. The influence of various experimental parameters such as initial fluoride content, feed pressure, permeate flux, ionic strength, type of cation associated to fluoride and pH were studied in the second part. Results show that the retention order for the salts tested was TR(Na 2 SO 4 ) > TR(CaCl 2 ) > TR(NaCl), showing a retention sequence inversely proportional to the salt diffusion coefficients in water. It was also shown that charge effects could not be neglected, and a titration experiments confirmed that the NF membrane carry a surplus of negatively charged groups. Fluoride retention exceeds 60 pour cent, and increases with increasing concentration, where the rejection mechanism is related to the dielectric effects. Speigler-Kedem model was applied to experimental results in the aim to determine phenomenological parametersσand P s respectively, the reflexion coefficient of the membrane and the solute permeability of ions. The convective and diffusive parts of the mass transfer were quantified with

  2. Comparison of Latanoprost and Brimonidine in the treatment of open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Man Luo

    2015-07-01

    Full Text Available AIM:To compare the efficacy and safety of latanoprost and brimonidine in the treatment of open angle glaucoma, and provide reference for rational drug use. METHODS:A total of 121 cases(136 eyeswho were diagnosed as primary open angle glaucoma were selected in this study, and they were randomly divided into experimental group(62 cases, 70 eyesand control group(59 cases, 66 eyesaccording to different drug treatment. Patients in the control group received brimonidine eye drops twice a day, while patients in the experimental group received latanoprost eye drops once a day. The intraocular pressure, visual acuity and adverse reactions were checked of the two groups in the following 3mo. RESULTS:The intraocular pressure of patients in the control group was 18.1±1.3mmHg, while the experimental group was 17.0±0.9mmHg after 12wk of treatment, which were both lower than before(PCONCLUSION:Latanoprost can significantly reduce intraocular pressure in glaucoma patients with in the follow-up time, and reduce the impact of elevated intraocular pressure in the vision of glaucoma patients, with little adverse reaction, worthy of clinical application.

  3. Glaucoma screening during regular optician visits : can the population at risk of developing glaucoma be reached?

    NARCIS (Netherlands)

    Stoutenbeek, R.; Jansonius, N. M.

    2006-01-01

    Aim: To determine the percentage of the population at risk of developing glaucoma, which can potentially be reached by conducting glaucoma screening during regular optician visits. Methods: 1200 inhabitants aged > 40 years were randomly selected from Dutch community population databases. A

  4. The glaucoma research foundation patient survey: patient understanding of glaucoma and its treatment.

    Science.gov (United States)

    Herndon, Leon W; Brunner, Thomas M; Rollins, Jane Neff

    2006-01-01

    Determine patients' understanding of glaucoma and its treatment, their sources of information about glaucoma, their preferences for treatment, their experience with medication side effects, and their reasons for changing eye doctors. Prospective, nonrandomized patient survey study. A questionnaire was developed and sent to the 22,000 subscribers of the Gleams newsletter who have glaucoma. Questionnaires were returned by 4310 glaucoma patients. Most respondents received glaucoma information from their eye doctor. Only 28% of respondents reported having changed eye doctors for reasons related to their glaucoma. Of those who had, 60% cited poor communication as the reason. When queried about specific side effects associated with their medication, over 85% of responding patients were never or rarely bothered by headaches and eyelid darkening. Most respondents (67% and 55%, respectively) were rarely or never disturbed by red eye or burning and stinging. Most respondents understood the importance of intraocular pressure (IOP) lowering in glaucoma, and of those patients who expressed a preference, 92% reported that they would prefer the medication that lowers IOP the most, even if it caused red eye for a few weeks, over a medication that caused no red eye but did not get IOP as low. Patients who subscribe to Gleams and responded to the survey rely most on their doctors for information about glaucoma and its treatment. Most understand the importance of maintaining low IOP to decrease the risk of vision loss, and most will tolerate temporary ocular side effects to achieve low IOP.

  5. Oculoplastic technique of connecting a glaucoma valve shunt to extraorbital locations in cases of severe glaucoma.

    Science.gov (United States)

    Rubin, Peter A D; Chang, Eli; Bernardino, Carlo Roberto; Hatton, Mark P; Dohlman, Claes H

    2004-09-01

    To describe a technique for inserting glaucoma shunts to the sinuses or the lacrimal sac as a means of lowering intraocular pressure in patients with refractory glaucoma associated with severe ocular surface disease. Nineteen patients with severe ocular surface disease necessitating a keratoprosthesis and with intractable glaucoma underwent placement of a modified Ahmed shunt to direct aqueous in the maxillary or ethmoid sinus or lacrimal sac. Intraocular pressure is presently well controlled without glaucoma medications in two thirds of patients. None of the patients had endophthalmitis. Established oculoplastic surgery techniques may be used to redirect aqueous to extraorbital locations and effectively lower intraocular pressure in patients with severe ocular surface disease and refractory glaucoma. This procedure has not been associated with endophthalmitis.

  6. Water filtration using plant xylem.

    Directory of Open Access Journals (Sweden)

    Michael S H Boutilier

    Full Text Available Effective point-of-use devices for providing safe drinking water are urgently needed to reduce the global burden of waterborne disease. Here we show that plant xylem from the sapwood of coniferous trees--a readily available, inexpensive, biodegradable, and disposable material--can remove bacteria from water by simple pressure-driven filtration. Approximately 3 cm(3 of sapwood can filter water at the rate of several liters per day, sufficient to meet the clean drinking water needs of one person. The results demonstrate the potential of plant xylem to address the need for pathogen-free drinking water in developing countries and resource-limited settings.

  7. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis.

    Science.gov (United States)

    Kalinina Ayuso, Viera; Scheerlinck, Laura M; de Boer, Joke H

    2013-03-01

    To assess the effect of Ahmed glaucoma valve implants on corneal endothelial cell density (ECD) in children with uveitic glaucoma. Cross-sectional study. setting: Institutional. patientpopulation: Eighty eyes from 42 patients diagnosed with uveitis before the age of 16. Twenty-eight eyes had an Ahmed glaucoma valve implant because of secondary glaucoma. Fifty-two eyes without an implant served as controls. intervention orobservationprocedure(s): Corneal ECD was examined cross-sectionally using a noncontact specular microscope. Univariate and multivariate generalized estimating equations analyses with correction for paired eyes were performed. mainoutcomemeasure(s): Correlation of ECD with the presence of an Ahmed glaucoma valve implant and with the time following implantation. ECD was significantly lower in the Ahmed glaucoma valve group than in controls (2359 and 3088 cells/mm(2), respectively; P Ahmed glaucoma valve implantation. Presence of an Ahmed glaucoma valve implant, previous intraocular surgery, age, duration of uveitis, and history of corneal touch by the implant tube were all significantly associated with decreased ECD. Following a multivariate analysis, presence of an Ahmed glaucoma valve implant (B = -340; adjusted P Ahmed glaucoma valve implantation was highly correlated with decreased ECD (B = -558, P Ahmed glaucoma valve implants in children with uveitic glaucoma are independently associated with decreased ECD, and this effect is associated with the time interval following Ahmed glaucoma valve implantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Ocular hemodynamics and glaucoma: the role of mathematical modeling.

    Science.gov (United States)

    Harris, Alon; Guidoboni, Giovanna; Arciero, Julia C; Amireskandari, Annahita; Tobe, Leslie A; Siesky, Brent A

    2013-01-01

    To discuss the role of mathematical modeling in studying ocular hemodynamics, with a focus on glaucoma. We reviewed recent literature on glaucoma, ocular blood flow, autoregulation, the optic nerve head, and the use of mathematical modeling in ocular circulation. Many studies suggest that alterations in ocular hemodynamics play a significant role in the development, progression, and incidence of glaucoma. Although there is currently a limited number of studies involving mathematical modeling of ocular blood flow, regulation, and diseases (such as glaucoma), preliminary modeling work shows the potential of mathematical models to elucidate the mechanisms that contribute most significantly to glaucoma progression. Mathematical modeling is a useful tool when used synergistically with clinical and laboratory data in the study of ocular blood flow and glaucoma. The development of models to investigate the relationship between ocular hemodynamic alterations and glaucoma progression will provide a unique and useful method for studying the pathophysiology of glaucoma.

  9. awareness and knowledge of glaucoma among adult patients

    African Journals Online (AJOL)

    PATIENTS AT THE EYE CLINIC OF A TEACHING HOSPITAL. G. NKUM1, S. LARTEY2, ... Background: Primary open angle glaucoma (POAG) is an irreversible .... If patients are aware of the risk factors and presentation of glaucoma, there will ...

  10. Potential applications of optical coherence tomography angiography in glaucoma.

    Science.gov (United States)

    Dastiridou, Anna; Chopra, Vikas

    2018-05-01

    Optical coherence tomography angiography (OCTA) is a novel, noninvasive imaging modality that allows assessment of the retinal and choroidal vasculature. The scope of this review is to summarize recent studies using OCTA in glaucoma and highlight potential applications of this new technology in the field of glaucoma. OCTA studies have shown that retinal vascular changes may not develop solely as a result of advanced glaucoma damage. OCTA-derived measurements have provided evidence for lower retinal vascular densities at the optic nerve head, peripapillary and macula in preperimetric-glaucoma and early-glaucoma, as well as, in more advanced glaucoma, in comparison to with normal eyes. OCTA is a novel imaging modality that has already started to expand our knowledge base regarding the role of ocular blood flow in glaucoma. Future studies will better elucidate the role of OCTA-derived measurements in clinical practice, research, and clinical trials in glaucoma.

  11. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  12. Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study

    Science.gov (United States)

    2017-05-02

    Glaucoma; Glaucoma Suspect; Diabetic Retinopathy; Ocular Hypertension; Cataract; Branch Retinal Vein Occlusion; Branch Retinal Arterial Occlusion; Central Retinal Vein Occlusion; Central Retinal Artery Occlusion; Epi-retinal Membrane; Macular Degeneration; Drusen; Loss of Vision

  13. Glaucoma

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research ... on Social Media Information in Spanish (Información en español) Website, Social Media Policies and Other Important Links ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... Clinical Studies Publications Catalog Photos ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... from NEI Grantees Spokesperson bios Statistics and Data ... to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov ...

  17. Glaucoma

    Science.gov (United States)

    ... un ser querido Ojos sanos Ojos sanos Problemas de visión comunes Enfermedades y condiciones de los ojos relacionadas con la edad Consejos simples ... Encontrando un Oculista Asistencia Financiera para el Cuidado de los Ojos Cómo ... in vision loss and blindness. It is one of the main causes of blindness in the United States. However, with ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us Visiting the NIH Campus Mission Statement As part ...

  20. Glaucoma

    Medline Plus

    Full Text Available ... Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ... This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website ...

  1. Glaucoma

    Medline Plus

    Full Text Available ... Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us ... government’s National Institutes of Health (NIH), the National Eye Institute’s mission is to “conduct and support research, ...

  2. Glaucoma

    Medline Plus

    Full Text Available ... is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications (301)496-5248 Health Information Frequently asked questions ...

  6. Glaucoma

    Medline Plus

    Full Text Available ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov NIH…Turning Discovery Into Health ®

  7. Glaucoma

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  11. Glaucoma

    Medline Plus

    Full Text Available Skip to main content Search Search: Search Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... part of the federal government’s National Institutes of Health (NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ...

  20. Glaucoma

    Medline Plus

    Full Text Available ... Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  1. Glaucoma

    Medline Plus

    Full Text Available ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  2. Glaucoma

    Medline Plus

    Full Text Available ... visual function, preservation of sight, and the special health problems and requirements of the blind.” News & Events Events ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. ... of Health and Human Services | The National Institutes of Health | ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of ... Social Media Information in Spanish (Información en español) Website, Social Media Policies and Other Important Links NEI ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  6. Glaucoma

    Medline Plus

    Full Text Available ... Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Office of the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... 496-5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding ... NEI Office of Communications (301)496-5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish ... Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... of visual function, preservation of sight, and the special health problems and requirements of the blind.” News & ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... 5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, Social ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this ...

  20. Glaucoma

    Medline Plus

    Full Text Available ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ... Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  1. Glaucoma

    Medline Plus

    Full Text Available ... blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  2. Glaucoma

    Medline Plus

    Full Text Available ... blind.” News & Events Events Calendar NEI Press Releases News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin. ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... Campus Mission Statement As part of the federal government’s National Institutes of Health (NIH), the National Eye ... Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  6. Glaucoma

    Science.gov (United States)

    ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Press Releases News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... blind.” News & Events Events Calendar ... Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  10. Determinants of glaucoma awareness and knowledge in urban Chennai

    Directory of Open Access Journals (Sweden)

    Sathyamangalam Ramesh

    2009-01-01

    Full Text Available Aim: To assess the awareness and knowledge levels about glaucoma and its determinants in an urban population of Chennai in south India. Materials and Methods: Chennai glaucoma study (CGS was a population based prevalence study to estimate the prevalence of glaucoma in a rural and urban south Indian population. A total of 3850 subjects aged 40 years or above participated in the urban arm of CGS. A systematic random sample of 1926 (50.0% subjects completed a questionnaire that assesses their awareness and knowledge level of glaucoma. Respondents "having heard of glaucoma" even before they were contacted/recruited for the study were defined as "aware" and respondents having some understanding of the eye disease were defined as "knowledgeable". Results: Overall 13.5% were aware of glaucoma, the age-gender adjusted rate for awareness was 13.3% (95% CI: 11.57 to 15.03. Two clinicians graded knowledge on glaucoma, based on the subject′s knowledge of risk factors, definitions and treatment aspects of glaucoma. Overall 8.7% had some knowledge about glaucoma. Among those who had knowledge 0.5% had good knowledge about glaucoma, 4% had fair knowledge and 4.2% had poor knowledge. We observed a very good agreement between the clinicians in grading knowledge (k =0.92. Determinants of glaucoma awareness and knowledge were higher levels of education, females, age, religion and family history of glaucoma. Conclusion: Awareness and knowledge about glaucoma was very low among the urban population of Chennai. We have found that younger subjects and men were less aware of glaucoma. Subjects with lower levels of education were less aware and knew less about glaucoma than their counterparts. The study findings stress the need for health education for effective prevention of blindness due to glaucoma.

  11. Demographic features of subjects with congenital glaucoma

    Science.gov (United States)

    Tamçelik, Nevbahar; Atalay, Eray; Bolukbasi, Selim; Çapar, Olgu; Ozkok, Ahmet

    2014-01-01

    Context: Congenital glaucoma is a potentially blinding ocular disease of the childhood. Identification of the possible associated risk factors and may be helpful for prevention or early detection of this public health problem. Aims: To demonstrate the demographic features of congenital glaucoma subjects. Setting and Design: The charts of congenital glaucoma patients referred to Tamcelik Glaucoma Center were retrospectively reviewed through the dates of 2000 and 2013. Materials and Methods: Analyzed data included diagnosis, age at first presentation, symptoms at first presentation, laterality of the disease, sex, presence of consanguinity, family history of congenital glaucoma, maturity of the fetus at delivery, and maternal age at conception. Statistical Analysis Used: Statistical Package for Social Sciences (SPSS) version 19.0 by IBM (SPSS Inc, Chicago, Illinois, USA) was used to compare the mean of continuous variables with Student's t-test and analysis of variance (ANOVA) and χ2 test was used to test differences in proportions of categorical variables. Results: The data of 600 eyes of 311 patients were analyzed. The distribution of primary and secondary congenital glaucoma among the patients were 63.3% (n = 197) and 36.7% (n = 114), respectively. Of the 311 patients, 57.2% (n = 178) were male and 42.8% (n = 133) were female. The overall frequency of bilateral disease was 92.3% (n = 287). Overall rate of consanguinity and positive family history was 45.3% (n = 141) and 21.2% (n = 66), respectively. Conclusions: Bilateral disease in this study was more common than previously reported studies. Positive family history was more frequent in primary congenital glaucoma although not statistically significant. PMID:24881602

  12. ASSOCIATION BETWEEN GLAUCOMA AND BLOOD GROUPS

    Directory of Open Access Journals (Sweden)

    F. Ghannadi R. Varmazyar

    2006-09-01

    Full Text Available There are reports from different countries that some types of glaucoma are associated with blood groups. This cross-sectional study was performed on 400 glaucomatous patients [100 patients in each group of Primary open angle glaucoma (POAG, chronic angle closure glaucoma (CACG, pseudoexfoliative glaucoma (PEXG and primary congenital glaucoma (PCG] and 400 blood donors as control group to assess the association between blood groups and glaucoma. All patients underwent ABO and Rh blood group testing. The prevalence of blood group A was 30% in the control group, 27% in POAG, 33% in CACA, 38% in PEXG and 36% in PCG. The prevalence of blood group B was 24% in the control group, 19% in POAG, 20% in CACG, 15% in PEXG and 34% in PCG (P < 0.025. The prevalence of blood group AB was 8% in the control group, 9% in POAG, 5% in CACG, 12% in PEXG, and 8% in PCG. The prevalence of blood group O was 38% in the control group, 45% in POAC, 42% in CACG, 35% in PEXG and 22% in PCG (P < 0.001. The prevalence of Rh+ was 88% in the control group, 84% in POAG, 87% in CACG, 86% in PEXG and 87% in PCG. Compared to control group, blood group B was more prevalent and blood group O was less prevalent in PCG. There was no association between other types of blood groups (ABO and Rh and PCG. There was no association between blood groups (ABO and Rh and other types of glaucoma.

  13. The medical management of glaucoma | Marais | South African ...

    African Journals Online (AJOL)

    Glaucoma is one of the leading causes of blindness worldwide. The main characteristic features include optic disc cupping, visual field loss, and in most instances a raised intraocular pressure. Primary open angle glaucoma accounts for nearly two thirds of all cases, while angle closure glaucoma contributes the majority of ...

  14. Goniodysgenesis in familial primary open-angle glaucoma

    NARCIS (Netherlands)

    Verbraak, F. D.; vd Berg, W.; Delleman, J. W.; Greve, E. L.

    1994-01-01

    Results of a pilot study to evaluate goniodysgenesis as a cause of familial open-angle glaucoma are reported. Patients with a familial high tension open-angle glaucoma and a goniodysgenetic chamber angle (n = 11), a number of their relatives with glaucoma (n = 12), and their relatives without

  15. Visual disability in Newly Diagnosed Primary open Angle Glaucoma ...

    African Journals Online (AJOL)

    Background: Glaucoma remains the second leading cause of blindness worldwide and the highest cause of irreversible blindness worldwide. In Nigeria, Glaucoma accounts for 16% of blindness and primary open angle glaucoma is the most prevalent clinical type. Aim: The aim of this study is to assess the visual disability ...

  16. Presentation of Primary Open Angle Glaucoma (POAG) at Lions ...

    African Journals Online (AJOL)

    Objective Primary open angle glaucoma (POAG) is the most common type of glaucoma in Africa. We carried out a study to determine the clinical presentation pattern of patients with primary open angle glaucoma (POAG) at a tertiary hospital in Malawi. Design A cross-sectional study. Setting Lions Sight First Eye Hospital—a ...

  17. Side Stream Filtration for Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-10-20

    This technology evaluation assesses side stream filtration options for cooling towers, with an objective to assess key attributes that optimize energy and water savings along with providing information on specific technology and implementation options. This information can be used to assist Federal sites to determine which options may be most appropriate for their applications. This evaluation provides an overview of the characterization of side stream filtration technology, describes typical applications, and details specific types of filtration technology.

  18. Relation Between Filtration and Soil Consolidation Theories

    OpenAIRE

    Strzelecki Tomasz; Strzelecki Michał

    2015-01-01

    This paper presents a different, than commonly used, form of equations describing the filtration of a viscous compressible fluid through a porous medium in isothermal conditions. This mathematical model is compared with the liquid flow equations used in the theory of consolidation. It is shown that the current commonly used filtration model representation significantly differs from the filtration process representation in Biot’s and Terzaghi’s soil consolidation models, which has a bearing on...

  19. Filtration of Sludge and Sodium Nonatitanate Solutions

    International Nuclear Information System (INIS)

    Poirier, M.R.

    2000-01-01

    The proposed facility designs for the ion exchange and solvent extraction flowsheets under development to treat high level waste at the Savannah River Site use crossflow filtration to remove entrained sludge and monosodium titanate (MST). Bench-scale and pilot-scale testing performed with simulated feed streams showed much lower filtration rates than desired for the process. This report documents an investigation of the impact on filtration of using Honeywell sodium nonatitanate (ST), rather than MST, for strontium and actinide removal

  20. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey

    OpenAIRE

    Daniel E. Grigera; Paulo Augusto Arruda Mello; Wilma Lelis Barbosa; Javier Fernando Casiraghi; Rodolfo Perez Grossmann; Alejo Peyret

    2013-01-01

    PURPOSE: The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. METHODS: An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1) and diagnosis (Part 2) of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. RESULTS: Fifty p...

  1. Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

    OpenAIRE

    Ranganath, Akshatha; Hashim, Adnan

    2011-01-01

    Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae...

  2. Cake creep during filtration of flocculated manure

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Keiding, Kristian

    is filtered. Hence, it is not possible to scale up the experiments, and it is therefore difficult to optimize the flocculation and estimate the needed filter media area. Similar problems have been observed when sewage sludge and synthetic core-shell colloids are filtered, and it has been suggested......, and the mixing procedure affect the result, and lab-scale experiments are often used to study how these pre-treatments influence the filtration process. However, the existing mathematical filtration models are based on filtration of inorganic particles and cannot simulate the filtration data obtained when manure...

  3. Filtration Behaviour and Fouling Mechanisms of Polysaccharides

    Directory of Open Access Journals (Sweden)

    Sondus Jamal

    2014-07-01

    Full Text Available This study investigated filtration behaviors of polysaccharides solutions, both alone and in mixture with proteins, in the short-time constant flux filtration with the focus on factors affecting the transmembrane pressure (TMP increase rate, the irreversible filtration resistance, and the membrane rejection behavior. The results showed that the TMP increase rates in the short-time constant flux filtration of alginate solutions were significantly affected by the calcium addition, alginate concentration, and flux. Although the addition of calcium resulted in a decrease in the TMP increase rate, it was found that the irreversible fouling developed during the filtration increased with the calcium addition, implying that the double-sided effect of calcium on membrane filtration and that the TMP increase rate observed in the filtration does not always reflect the irreversible membrane fouling development. It was also found that for the filtration of solutions containing mixed alginate and BSA, alginate exerted a dominant effect on the TMP increase rate and the membrane exhibited a reduced rejection to both alginate and BSA molecules compared to that in the filtration of the pure alginate or BSA.

  4. Effect of phosphate ion on filtration characteristics of solids generated in simulated high level liquid waste

    International Nuclear Information System (INIS)

    Kondo, Y.

    1998-01-01

    The effect of phosphate ion on the filtration characteristics of solids generated in a high level liquid waste was experimentally examined. Addition of phosphate ion into the simulated HLLW induced the formation of phosphate such as zirconium phosphate and phosphomolybdic acid. The filtration rate of zirconium phosphate abruptly dropped in the midst of filtration because of a gel-cake formation on the filter surface. The denitration of the simulated HLLW contained zirconium phosphate improved the filterability of this gelatinous solid. The filtration rates of denitrated HLLW decreased with increase of the phosphate ion concentration, since the solids formed by denitration had irregular particle size and configuration in the simulated HLLW with phosphate ion. To increase the filtration rate of denitrated HLLW, a solid suspension filtration tester was designed. The solid-suspension accelerated the filtration rate only in the simulated HLLW with more than 1500 ppm phosphate ion concentration. Under this condition, the simple agitation can easily suspend the constituent solids of filter cake in the solution and a much higher filtration rate can be obtained because the filter cake is continuously swept from the filter surface by rotation of propellers. (authors)

  5. 24-h Efficacy of Glaucoma Treatment Options.

    Science.gov (United States)

    Konstas, Anastasios G P; Quaranta, Luciano; Bozkurt, Banu; Katsanos, Andreas; Garcia-Feijoo, Julian; Rossetti, Luca; Shaarawy, Tarek; Pfeiffer, Norbert; Miglior, Stefano

    2016-04-01

    Current management of glaucoma entails the medical, laser, or surgical reduction of intraocular pressure (IOP) to a predetermined level of target IOP, which is commensurate with either stability or delayed progression of visual loss. In the published literature, the hypothesis is often made that IOP control implies a single IOP measurement over time. Although the follow-up of glaucoma patients with single IOP measurements is quick and convenient, such measurements often do not adequately reflect the untreated IOP characteristics, or indeed the quality of treated IOP control during the 24-h cycle. Since glaucoma is a 24-h disease and the damaging effect of elevated IOP is continuous, it is logical that we should aim to understand the efficacy of all treatment options throughout the 24-h period. This article first reviews the concept and value of diurnal and 24-h IOP monitoring. It then critically evaluates selected available evidence on the 24-h efficacy of medical, laser and surgical therapy options. During the past decade several controlled trials have significantly enhanced our understanding on the 24-h efficacy of all glaucoma therapy options. Nevertheless, more long-term evidence is needed to better evaluate the 24-h efficacy of glaucoma therapy and the precise impact of IOP characteristics on glaucomatous progression and visual prognosis.

  6. Short term outcome of Ahmed glaucoma valve implantation in management of refractory glaucoma in a tertiary hospital in Oman

    Science.gov (United States)

    Shah, Manali R.; Khandekar, Rajiv B.; Zutshi, Rajiv; Mahrooqi, Rahima

    2013-01-01

    Background: We present outcomes of Ahmed Glaucoma Valve (AGV) implantation in treating refractory glaucoma in a tertiary hospital in Oman. Refractory glaucoma was defined as previously failed conventional glaucoma surgery and an uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite treatment with three topical and/or oral therapy. Materials and Methods: This historical cohort study was conducted in 2010. Details of medical and surgical treatment were recorded. Ophthalmologists examined eyes and performed glaucoma surgeries using AGV. The best corrected distant vision, IOP, and glaucoma medications were prospectively reviewed on 1st day, 1st, 6th, 12th week postoperatively, and at the last follow up. Result: Glaucoma specialists examined and treated 40 eyes with refractory glaucoma of 39 patients (20 males + 19 females). Neo-vascular glaucoma was present in 23 eyes. Vision before surgery was glaucoma medications (2.38; SD 1.1) was reduced compared to the mean number of postoperative medications (1.92; SD 0.9) at 12 weeks. Conclusion: We succeeded in reducing visual disabilities and the number of anti-glaucoma medications used to treat refractory glaucoma by AGV surgery. PMID:23772122

  7. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    Science.gov (United States)

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  8. [Long-term outcomes of Ahmed glaucoma valve implantation for treating refractory glaucoma].

    Science.gov (United States)

    Xu, Yumei; Hong, Tao; Li, Wanming

    2015-02-10

    To explore the efficacies and complications of Ahmed glaucoma valve implantation for treating refractory glaucoma. A retrospective study of case series was conducted for 24 patients (26 eyes) with refractory glaucoma from February 2001 to July 2008 at our hospital. Ahmed glaucoma valve implantation was performed. Pre- and post-operative best spectacle-corrected visual acuity (BSCVA), intraocular pressure (IOP), number of medications and complications were recorded and analyzed. The follow-up period was 58-159 months. The post-operative values of IOP were 13.02+/-6.79, 11.43+/-5.24 and 18.56+/-6.43 mmHg at 1 day, 1 month and the last follow-up respectively. There were significant difference when compared with pre-operative IOP (37.59+/-10.76 mmHg, P glaucoma drugs after glaucoma valve implantation and the average number of medication was 1.72+/-0.98. There was significant difference with the pre-operative medication number 2.7 ± 0.7 (P = 0.001). The surgical success rate was 73.1%. And the causes of failure were endophthalmitis, corneal endothelial decompensation, persistent conjunctival wound non-healing, glaucoma valve exposure and loss of light perception.Early postoperative complications were ocular hypotony, shallow anterior chamber, hyphema, transient high IOP and tube occlusion. And long-term complications included encapsulated cyst formation, tube exposure, corneal endothelial decompensation and endophthalmitis. Ahmed glaucoma valve implantation is efficacious for refractory glaucoma.However, clinicians should pay attention to the prevention and treatment of complications.

  9. A prospective comparative study on neovascular glaucoma and non-neovascular refractory glaucoma following Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Li, Zheng; Zhou, Minwen; Wang, Wei; Huang, Wenbin; Chen, Shida; Li, Xingyi; Gao, Xinbo; Zhang, Xiulan

    2014-01-01

    Neovascular glaucoma is a refractory disease, and difficult to manage. The aim of this study was to evaluate the clinical outcomes of Ahmed glaucoma valve implantation (AGVI) in neovascular glaucoma (NVG) and non-NVG patients. This prospective, non-randomized study included 55 eyes of 55 patients with refractory glaucoma; 27 had NVG (NVG group) and 28 had non-NVG (non-NVG group). All of the patients underwent AGVI. The NVG group was adjunctively injected with intravitreal ranibizumab/bevacizumab (IVR/IVB) before AGVI. Intraocular pressure (IOP) was the primary outcome measure in this study. Surgical success rate, number of antiglaucoma medications used, best corrected visual acuity (BCVA), and postoperative complications were analyzed between the groups. All of the patients completed the study (follow-up of 12 months). Kaplan-Meier survival curve analysis indicated that the qualified success rates in the NVG and non-NVG groups at 12 months were 70.5% and 92.9%, respectively; this difference was significant (P = 0.036). The complete success rates in the NVG and non-NVG groups at 12 months were 66.7% and 89.3%, respectively (P = 0.049). Compared with preoperative examinations, the postoperative mean IOP and use of medications were significantly lower at all follow-up time points in both groups (all P glaucoma, but the success rate of surgery was related to the type of refractory glaucoma. The complete and qualified success rates of NVG patient adjunctive anti-vascular endothelial growth factor treatment are still lower than those of non-NVG patients.

  10. Evaluation of Ocular Surface Disease in Patients with Glaucoma

    Science.gov (United States)

    Mathews, Priya M.; Ramulu, Pradeep Y.; Friedman, David S.; Utine, Canan A.; Akpek, Esen K.

    2013-01-01

    Purpose To evaluate the subjective and objective measures of ocular surface disease in patients with glaucoma. Design Cross-sectional study. Participants Sixty-four glaucoma subjects with bilateral visual field (VF) loss and 59 glaucoma suspects with normal VFs. Methods Consecutive patients were recruited prospectively from the Wilmer Eye Institute Glaucoma Clinic. Main Outcome Measures Tear film breakup time (TBUT), corneal staining score (0–15), and Schirmer’s test results were included as objective metrics, whereas the Ocular Surface Disease Index (OSDI) questionnaire was administered to assess symptoms. Total OSDI score, vision-related subscore (derived from questions about vision and task performance), and discomfort-related subscore (derived from questions about ocular surface discomfort) were calculated for each subject. Results Seventy-five percent (48/64) of glaucoma subjects and 41% (24/59) of glaucoma suspects were receiving topical medications. The corneal staining grade was greater in glaucoma subjects than in glaucoma suspects (6.4 vs. 4.1; P0.20 for both). Multivariate regression models showed that topical glaucoma therapy burden was associated with a significantly higher total corneal staining grade (β, +0.9 for each additional glaucoma drop; 95% confidence interval [CI], 0.5–1.3; P0.20 for both). Glaucoma subjects had significantly higher total OSDI scores than glaucoma suspects (16.7 vs. 7.9; Pglaucoma group (11.1 vs. 3.3; Pglaucoma therapy burden was not associated with higher total OSDI score or vision- or discomfort-related subscore (P>0.20 for all). Conclusions Glaucoma is associated with significant ocular surface disease, and topical glaucoma therapy burden seems predictive of corneal staining severity. However, OSDI is a poor metric for capturing ocular surface disease in glaucoma because symptoms seem to be related largely to VF loss. PMID:23714318

  11. Ahmed glaucoma valve in post-penetrating-keratoplasty glaucoma: A critically evaluated prospective clinical study

    Science.gov (United States)

    Panda, Anita; Prakash, Vadivelu Jaya; Dada, Tanuj; Gupta, Anoop Kishore; Khokhar, Sudarshan; Vanathi, Murugesan

    2011-01-01

    Aim: The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV) in post-penetrating-keratoplasty glaucoma (PKPG). Materials and Methods: In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP) >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7) implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5 glaucoma managed by AGV implantation revealed a satisfactory outcome up to 6 months of follow-up. PMID:21586837

  12. Trabecular meshwork stiffness in glaucoma.

    Science.gov (United States)

    Wang, Ke; Read, A Thomas; Sulchek, Todd; Ethier, C Ross

    2017-05-01

    Alterations in stiffness of the trabecular meshwork (TM) may play an important role in primary open-angle glaucoma (POAG), the second leading cause of blindness. Specifically, certain data suggest an association between elevated intraocular pressure (IOP) and increased TM stiffness; however, the underlying link between TM stiffness and IOP remains unclear and requires further study. We here first review the literature on TM stiffness measurements, encompassing various species and based on a number of measurement techniques, including direct approaches such as atomic force microscopy (AFM) and uniaxial tension tests, and indirect methods based on a beam deflection model. We also briefly review the effects of several factors that affect TM stiffness, including lysophospholipids, rho-kinase inhibitors, cytoskeletal disrupting agents, dexamethasone (DEX), transforming growth factor-β 2 (TGF-β 2 ), nitric oxide (NO) and cellular senescence. We then describe a method we have developed for determining TM stiffness measurement in mice using a cryosection/AFM-based approach, and present preliminary data on TM stiffness in C57BL/6J and CBA/J mouse strains. Finally, we investigate the relationship between TM stiffness and outflow facility between these two strains. The method we have developed shows promise for further direct measurements of mouse TM stiffness, which may be of value in understanding mechanistic relations between outflow facility and TM biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Development of a novel CsA-PLGA drug delivery system based on a glaucoma drainage device for the prevention of postoperative fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Zhaoxing; Yu, Xiaobo; Hong, Jiaxu; Liu, Xi [Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031 (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031 (China); Sun, Jianguo, E-mail: sjgsun@126.com [Research Center, Eye & ENT Hospital, Fudan University, Shanghai 200031 (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031 (China); State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200031 (China); Sun, Xinghuai, E-mail: xhsun@shmu.edu.cn [Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031 (China); Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031 (China)

    2016-09-01

    The formation of a scar after glaucoma surgery often leads to unsuccessful control of intraocular pressure, and should be prevented by using a variety of methods. We designed and developed a novel drug delivery system (DDS) comprising cyclosporine A (CsA) and poly(lactic-co-glycolic acid) (PLGA) based on a glaucoma drainage device (GDD) that can continuously release CsA to prevent postoperative fibrosis following glaucoma surgery. The CsA@PLGA@GDD DDS was observed by field emission scanning electron microscopy and revealed an asymmetric pore structure. Thermogravimetric analysis was performed to measure the weight loss and evaluate the thermal stability of the CsA@PLGA@GDD DDS. The in vitro drug release profile of the DDS was studied using high performance liquid chromatography, which confirmed that the DDS released CsA at a stable rate and maintained adequate CsA concentrations for a relatively long time. The biocompatibility of the DDS and the inhibitory effects on the postoperative fibrosis were investigated in vitro using rabbit Tenon's fibroblasts. The in vivo safety and efficacy of the DDS were examined by implanting the DDS into Tenon's capsules in New Zealand rabbits. Bleb morphology, intraocular pressure, anterior chamber reactions, and anterior chamber angiography were studied at a series of set times. The DDS kept the filtration pathway unblocked for a longer time compared with the control GDD. The results indicate that the CsA@PLGA@GDD DDS represents a safe and effective strategy for preventing scar formation after glaucoma surgery. - Highlights: • CsA@PLGA@GDD drug delivery system (DDS) was designed and prepared successfully. • The DDS released CsA at a stable rate for > 3 months. • The DDS kept filtration pathway unblocked for a longer time than control. • CsA@PLGA@GDD DDS prevented glaucoma scar formation as a safe and effective strategy.

  14. Development of a novel CsA-PLGA drug delivery system based on a glaucoma drainage device for the prevention of postoperative fibrosis

    International Nuclear Information System (INIS)

    Dai, Zhaoxing; Yu, Xiaobo; Hong, Jiaxu; Liu, Xi; Sun, Jianguo; Sun, Xinghuai

    2016-01-01

    The formation of a scar after glaucoma surgery often leads to unsuccessful control of intraocular pressure, and should be prevented by using a variety of methods. We designed and developed a novel drug delivery system (DDS) comprising cyclosporine A (CsA) and poly(lactic-co-glycolic acid) (PLGA) based on a glaucoma drainage device (GDD) that can continuously release CsA to prevent postoperative fibrosis following glaucoma surgery. The CsA@PLGA@GDD DDS was observed by field emission scanning electron microscopy and revealed an asymmetric pore structure. Thermogravimetric analysis was performed to measure the weight loss and evaluate the thermal stability of the CsA@PLGA@GDD DDS. The in vitro drug release profile of the DDS was studied using high performance liquid chromatography, which confirmed that the DDS released CsA at a stable rate and maintained adequate CsA concentrations for a relatively long time. The biocompatibility of the DDS and the inhibitory effects on the postoperative fibrosis were investigated in vitro using rabbit Tenon's fibroblasts. The in vivo safety and efficacy of the DDS were examined by implanting the DDS into Tenon's capsules in New Zealand rabbits. Bleb morphology, intraocular pressure, anterior chamber reactions, and anterior chamber angiography were studied at a series of set times. The DDS kept the filtration pathway unblocked for a longer time compared with the control GDD. The results indicate that the CsA@PLGA@GDD DDS represents a safe and effective strategy for preventing scar formation after glaucoma surgery. - Highlights: • CsA@PLGA@GDD drug delivery system (DDS) was designed and prepared successfully. • The DDS released CsA at a stable rate for > 3 months. • The DDS kept filtration pathway unblocked for a longer time than control. • CsA@PLGA@GDD DDS prevented glaucoma scar formation as a safe and effective strategy.

  15. A link between diabetes mellitus and glaucoma

    DEFF Research Database (Denmark)

    Horwitz, A.; Petrovski, B.E; Petrovski, G.

    2016-01-01

    -year follow-up period. The National Danish Registry of Medicinal Products Statistics was used to identify all claimed prescriptions for glaucoma medication and anti-diabetic drugs. Comorbidities with diabetic retinopathy and diabetic nephropathy were identified using the ICD-10 classification......-diabetic drugs at any time during the study period had a significantly higher overall relative risk of glaucoma (RR = 5.11, p age, gender, diabetic retinopathies and calendar year-fixed effects (RR = 2.05, p ... of glaucoma overall, while treatment with β-blocker and RAS, in combination, are associated with a significantly lower risk (HR = 0.87). Conclusions Use of anti-diabetic drugs is strongly associated with use of anti-glaucomatous drugs. Diabetic complication as well as concomitant antihypertensive medications...

  16. Ahmed glaucoma valve in children: A review☆

    Science.gov (United States)

    Nassiri, Nariman; Nouri-Mahdavi, Kouros; Coleman, Anne L.

    2011-01-01

    Pediatric glaucoma is potentially a blinding disease. Although goniotomy and trabeculotomy are associated with good early success rates, eventually 20% of these procedures fail and many children will require additional surgery to control the IOP in the long-term. In this review, we reported that adequate IOP control can be achieved with the placement of Ahmed glaucoma valve and can last 5 or more years. However, most patients will need one or more glaucoma medications at some point after surgery. In addition, the implants may be associated with pupillary irregularities, lenticular opacification as well as tube-related complications, particularly in the first year of life, as the globe is enlarging with age. PMID:23960945

  17. BILATERAL STEROID INDUCED GLAUCOMA IN VERNAL KERATOCONJUNCTIVITIS

    Directory of Open Access Journals (Sweden)

    Bangal Surekha V, Bankar Mahima S, Bhandari Akshay J, Kalkote Prasad R

    2015-01-01

    Full Text Available Vernal Keratoconjunctivits (VKC is a bilateral recurrent allergic interstitial conjunctival inflammation with a periodic seasonal incidence and of self limiting nature, mainly affecting the younger population. Patients of VKC on steroid therapy are at higher risk of developing steroid induced glaucoma. Raised intraocular pressure due to steroids typically occurs within few weeks of starting steroid therapy and comes back to normal on immediate stoppage of steroids. A case of steroid induced glaucoma in a 30 years old female with vernal keratoconjunctivitis. She was on topical steroids for 3-4 years. She was incompliant with the instructions to stop steroids. She eventually developed steroid induced glaucoma and glaucomatous optic neuropathy with tunnel vision.

  18. Unilateral glaucoma in Sotos syndrome (cerebral gigantism).

    Science.gov (United States)

    Yen, M T; Gedde, S J; Flynn, J T

    2000-12-01

    To report a patient with unilateral glaucoma associated with Sotos syndrome. Sotos syndrome (cerebral gigantism) is a disorder of growth and development with characteristic facial changes and normal endocrine function. Ocular manifestations may also include megalocornea, iris hypoplasia, cataracts, megalophthalmos, strabismus, nystagmus, and retinal dystrophy. Case report. A 50 year-old man with the clinical features of Sotos syndrome presented with complaints of decreased vision in the left eye. Ophthalmologic examination revealed bilateral megalocornea, megalophthalmos, iris hypoplasia and transillumination defects, cataracts, and unilateral glaucoma. Intraocular pressure was lowered, and visual field loss was stabilized with topical medications. Sotos syndrome patients should be examined routinely to allow for early detection and treatment of potential ocular problems, including glaucoma.

  19. Current concepts in the pathophysiology of glaucoma

    Directory of Open Access Journals (Sweden)

    Agarwal Renu

    2009-01-01

    Full Text Available Glaucoma, the second leading cause of blindness, is characterized by changes in the optic disc and visual field defects. The elevated intraocular pressure was considered the prime factor responsible for the glaucomatous optic neuropathy involving death of retinal ganglion cells and their axons. Extensive investigations into the pathophysiology of glaucoma now reveal the role of multiple factors in the development of retinal ganglion cell death. A better understanding of the pathophysiological mechanisms involved in the onset and progression of glaucomatous optic neuropathy is crucial in the development of better therapeutic options. This review is an effort to summarize the current concepts in the pathophysiology of glaucoma so that newer therapeutic targets can be recognized. The literature available in the National Medical Library and online Pubmed search engine was used for literature review.

  20. [Influence of Luxury Foodstuffs on Glaucoma].

    Science.gov (United States)

    Huber-van der Velden, K K

    2017-02-01

    The term "luxury foodstuffs" refers to foods which are not consumed because of their nutritional value. Classic modern luxury foodstuffs are alcohol, caffeine-containing drinks, cocoa, sugar and tobacco. The following review article examines some of these modern luxury foodstuffs in detail, as well as their influence on glaucoma. Thus, small quantities of alcohol lower high intraocular pressure and have a positive influence on the blood circulation of the optic nerve. In addition, red wine polyphenols exert vasoprotective effects. In general, however, alcohol consumption appears to have no significant effect on the prevalence of glaucoma. The most important source of caffeine intake is coffee consumption. In some studies, coffee consumption caused no changes in intraocular pressure, while others reported a rise. A large study showed a connection between heavy coffee consumption and the risk of pseudoexfoliation glaucoma. Green and black teas are rich sources of flavonoids with antioxidant activity. In addition, a slight trend for lowering the intraocular pressure has been measured. As regards chocolate, flavonoid-rich dark chocolate should be favoured, due to its antioxidant activity. It lowers blood pressure and improves endothelium-dependent vascular relaxation. Excessive sugar consumption over many years can lead to increased body mass index (BMI) and type 2 diabetes. Many studies show a positive relationship between BMI and intraocular pressure. Some studies have identified significant correlations between type 2 diabetes and the risk of glaucoma. Smoking is a very widespread stimulant; it narrows the blood vessels and thus reduces the blood circulation of the optic nerve. Otherwise, studies on the role of smoking as a risk factor for glaucoma have been very inconsistent. Luxury foodstuffs may effect glaucoma and should be included in the medical history. Georg Thieme Verlag KG Stuttgart · New York.

  1. Filtration and retention capacities of filter aids

    International Nuclear Information System (INIS)

    Mellah, A.; Boualia, A.

    1992-01-01

    The present work involves the filtration of impure uranyl nitrate solutions by different filter aids such as kieselguhr, celite and bleaching clay. The retention of substances contained in uranyl nitrate solution was determined using the three filter aids. A study of the effects of granulometry and filter earths treatment (thermal and chemical) on the filtration rate was performed

  2. 40 CFR 141.73 - Filtration.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Filtration and Disinfection § 141.73 Filtration. A public water system that uses a surface water source or a ground water source under the direct influence of surface water...

  3. Management of Blood Pressure in Patients with Glaucoma.

    Science.gov (United States)

    Levine, Russell M; Yang, Alina; Brahma, Venkatesh; Martone, James F

    2017-09-19

    Ocular perfusion pressure (OPP) is defined as the difference between BP and intraocular pressure (IOP). With low BP comes low OPP and resultant ischemic damage to the optic nerve, leading to glaucoma progression. The purpose of this article is to review the literature on BP as it relates to glaucoma and to create a forum of discussion between ophthalmologists and internal medicine specialists. Both high and low BP has been linked glaucoma. Low BP is particularly associated with glaucoma progression in normal-tension glaucoma (NTG) patients. Patients who have low nighttime BP readings are at highest risk of progression of their glaucoma. Internal medicine specialists and ophthalmologists should consider the relationship between BP and glaucoma when treating patients with concomitant disease. Too-low nighttime BP should be avoided. Ambulatory blood pressure monitoring is a useful tool to identify patients at greatest risk for progression.

  4. Regional Retinal Ganglion Cell Axon Loss in a Murine Glaucoma Model.

    Science.gov (United States)

    Schaub, Julie A; Kimball, Elizabeth C; Steinhart, Matthew R; Nguyen, Cathy; Pease, Mary E; Oglesby, Ericka N; Jefferys, Joan L; Quigley, Harry A

    2017-05-01

    To determine if retinal ganglion cell (RGC) axon loss in experimental mouse glaucoma is uniform in the optic nerve. Experimental glaucoma was induced for 6 weeks with a microbead injection model in CD1 (n = 78) and C57BL/6 (B6, n = 68) mice. From epoxy-embedded sections of optic nerve 1 to 2 mm posterior to the globe, total nerve area and regional axon density (axons/1600 μm2) were measured in superior, inferior, nasal, and temporal zones. Control eyes of CD1 mice have higher axon density and more total RGCs than control B6 mice eyes. There were no significant differences in control regional axon density in all mice or by strain (all P > 0.2, mixed model). Exposure to elevated IOP caused loss of RGC in both strains. In CD1 mice, axon density declined without significant loss of nerve area, while B6 mice had less density loss, but greater decrease in nerve area. Axon density loss in glaucoma eyes was not significantly greater in any region in either mouse strain (both P > 0.2, mixed model). In moderately damaged CD1 glaucoma eyes, and CD1 eyes with the greatest IOP elevation exposure, density loss differed by region (P = 0.05, P = 0.03, mixed model) with the greatest loss in the temporal and superior regions, while in severely injured B6 nerves superior loss was greater than inferior loss (P = 0.01, mixed model, Bonferroni corrected). There was selectively greater loss of superior and temporal optic nerve axons of RGCs in mouse glaucoma at certain stages of damage. Differences in nerve area change suggest non-RGC responses differ between mouse strains.

  5. Definition, Classification, and Pathophysiology of Canine Glaucoma.

    Science.gov (United States)

    Pizzirani, Stefano

    2015-11-01

    Glaucoma is a common ocular condition in humans and dogs leading to optic nerve degeneration and irreversible blindness. Primary glaucoma is a group of spontaneous heterogeneous diseases. Multiple factors are involved in its pathogenesis and these factors vary across human ethnic groups and canine breeds, so the clinical phenotypes are numerous and their classification can be challenging and remain superficial. Aging and oxidative stress are major triggers for the manifestation of disease. Multiple, intertwined inflammatory and biochemical cascades eventually alter cellular and extracellular physiology in the optic nerve and trabecular meshwork and lead to vision loss. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Particle filtration in consolidated granular systems

    International Nuclear Information System (INIS)

    Schwartz, L.M.; Wilkinson, D.J.; Bolsterli, M.; Hammond, P.

    1993-01-01

    Grain-packing algorithms are used to model the mechanical trapping of dilute suspensions of particles by consolidated granular media. We study the distribution of filtrate particles, the formation of a damage zone (internal filter cake), and the transport properties of the host--filter-cake composite. At the early stages of filtration, our simulations suggest simple relationships between the structure of the internal filter cake and the characteristics of the underlying host matrix. These relationships are then used to describe the dynamics of the filtration process. Depending on the grain size and porosity of the host matrix, calculated filtration rates may either be greater than (spurt loss) or less than (due to internal clogging) those predicted by standard surface-filtration models

  7. Generic versus brand-name North American topical glaucoma drops.

    Science.gov (United States)

    Mammo, Zaid N; Flanagan, John G; James, David F; Trope, Graham E

    2012-02-01

    To determine whether brand-name glaucoma drops differ from generic equivalents in bottle design, viscosity, surface tension, and volume in North America. Experimental study. We studied 5 bottles each of 11 kinds of glaucoma drops. Density-based calculations of drop volume were assessed using 0.1 mg analytic balance. Viscosity was measured using rotational rheometery. Bottle tip diameter was measured using 0.05 mm Vernier calipers. Surface tension was measured using a Fisher Scientific (Ottawa, ON) tensiometer. For the American brand-name Timoptic XE, the average drop volume was 38 ± 3.1 μL versus 24 ± 1.5 μL of Timolol GFS (p brand-name Timoptic XE, the average drop volume was 42 ± 4.0 μL versus 25 ± 2 μL of timolol maleate EX (p brand-name Timoptic drop volume was 28 ± 1.4 μL versus 35 ± 1.9 μL Apo-Timop (p brand-name Timoptic delivered significantly smaller drop volumes than generic Apo-Timop. Careful consideration should be given to drop viscosity and bottle design when generic ophthalmic products are evaluated for interchangeability and market entry. Copyright © 2012 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  8. Visual Field Defects and Retinal Ganglion Cell Losses in Human Glaucoma Patients

    Science.gov (United States)

    Harwerth, Ronald S.; Quigley, Harry A.

    2007-01-01

    Objective The depth of visual field defects are correlated with retinal ganglion cell densities in experimental glaucoma. This study was to determine whether a similar structure-function relationship holds for human glaucoma. Methods The study was based on retinal ganglion cell densities and visual thresholds of patients with documented glaucoma (Kerrigan-Baumrind, et al.) The data were analyzed by a model that predicted ganglion cell densities from standard clinical perimetry, which were then compared to histologic cell counts. Results The model, without free parameters, produced accurate and relatively precise quantification of ganglion cell densities associated with visual field defects. For 437 sets of data, the unity correlation for predicted vs. measured cell densities had a coefficient of determination of 0.39. The mean absolute deviation of the predicted vs. measured values was 2.59 dB, the mean and SD of the distribution of residual errors of prediction was -0.26 ± 3.22 dB. Conclusions Visual field defects by standard clinical perimetry are proportional to neural losses caused by glaucoma. Clinical Relevance The evidence for quantitative structure-function relationships provides a scientific basis of interpreting glaucomatous neuropathy from visual thresholds and supports the application of standard perimetry to establish the stage of the disease. PMID:16769839

  9. Clinical observation on Ahmed glaucoma valve implantation for teenagers with refractory glaucoma

    Directory of Open Access Journals (Sweden)

    Dong-Dao Song

    2016-06-01

    Full Text Available AIM:To observe the clinical effect of Ahmed glaucoma valve(AGVimplantation for teenagers with refractory glaucoma. METHODS: Twenty-seven patients(27 eyeswith refractory glaucoma were treated with AGV implantation in our hospital from October 2012 to October 2014. The patients were followed up for 12mo. The success rate of the operation, postoperative intraocular pressure, the best corrected visual acuity, as well as complications were recorded. RESULTS: The success rate of the operation was 85%. The intraocular pressure of the 27 patients decreased from 48.3±8.3mmHg before operations to 21.4±8.1mmHg(PPCONCLUSION: AGV implantation is characterized by a high success rate, simple operation, less complications and is an effective treatment for refractory glaucoma in adolescents.

  10. Managing high risk glaucoma with the Ahmed valve implant: 20 years of experience

    Directory of Open Access Journals (Sweden)

    Tryfon Rotsos

    2018-02-01

    Full Text Available AIM: To estimate the efficacy and safety of the Ahmed implant in patients with high risk for failure after glaucoma surgery. METHODS: In 342 eyes of 342 patients with refractory glaucoma, even with application of medical treatment, the Ahmed valve was introduced for intraocular pressure (IOP control, in the period of the last 20y. The nature of glaucoma was neovascular in 162 eyes, pseudophakic or aphakic in 49 eyes, inflammatory in 29 eyes and non working previous antiglaucomatic surgical interventions in 102 eyes. RESULTS: Follow-up ranged from 18 to 120mo with a mean follow-up of 63.2mo. IOP before the operation decreased from 31.6±10.4 mm Hg to 18.3±5.4 mm Hg (no systemic treatment at the end of follow up period. When we compared the IOP values before the operation using ANOVA showed statistically significant difference (P<0.001. The success rate was 85.2% during the first semester, 76.8% at 12mo and 50.3% at the end of follow up period (18 to 120mo after implantation. Success rate was 25.7% in neovascular glaucoma, 63.2% in aphakic glaucoma and 73.8% in non working previous antiglaucomatic surgical interventions. Complications due to the implant were: serous choroidal detachment in 14.8%, blockage of the tube in 2.8%, malposition of the tube in 4.9%, suprachoroidal hemorrhage in 2.1%, cataract progression in 39.6% (phakic eyes, shallow anterior chamber in 9.2%, hyphaema in 28.9%, exposure of valve in 2.6%, exposure of tube in 9.3%, hypotony in 4.9% and conjunctival fibrosis in 41.5%. CONCLUSION: Despite the fact that Ahmed valve implant had suchlike results as other implants concerning the IOP control, complications rate due to hypotony or over filtration in the first days after the intervention are not that frequent as with other valve implants.

  11. Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Satana, Banu; Yalvac, Ilgaz S; Sungur, Gulten; Eksioglu, Umit; Basarir, Berna; Altan, Cigdem; Duman, Sunay

    2015-01-01

    To evaluate outcomes of patients with uveitic glaucoma secondary to Behçet disease (BD) who underwent Ahmed glaucoma valve (AGV) implantation. A retrospective chart review of 14 eyes of 10 patients with uveitic glaucoma associated with BD who underwent AGV implantation at a tertiary referral center. Treatment success was defined as intraocular pressure (IOP) between 6 and 21 mm Hg with or without antiglaucoma medication, without further additional glaucoma surgery or loss of light perception. The main outcome measures were IOP, best-corrected visual acuity measured with Snellen charts, and number of glaucoma medications. Mean duration of postoperative follow-up was 18.2±6.6 months (range, 6 to 31 mo). Of the 14 eyes, 10 (71.4%) were pseudophakic and 5 (35.7%) had primary AGV implantation without a history of previous glaucoma surgery. At the most recent follow-up visit, 13 of the 14 eyes had an IOP between 6 and 21 mm Hg. Mean IOP was significantly reduced during follow-up, as compared with preoperative values (P≤0.005). The cumulative probability of surgical success rate was 90.9% at 18 months based on Kaplan-Meier survival analysis. The mean number of antiglaucoma medications required to achieve the desired IOP decreased from 3.4±0.5 preoperatively to 1.0±1.1 postoperatively (P≤0.05). Visual acuity loss of >2 lines occurred in 4 eyes (28.5%) due to optic atrophy associated with retinal vasculitis. Temporary hypotony developed during follow-up in 4 eyes (28.5%) at first postoperative week. For the management of uveitic glaucoma associated with BD, AGV implantation is a successful method for glaucoma control but requires additional surgical interventions for high early hypotony rates.

  12. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    OpenAIRE

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Jingjing Huang,1 Jialiu Lin,1 Ziqiang Wu,2 Hongzhi Xu,3 Chengguo Zuo,1 Jian Ge1 1State Key Laboratory of Ophthalmology, Department of Glaucoma, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People’s Republic of China; 2Center for Advanced Eye Care, Carson City, NV, USA; 3Institute of Child Health Policy, University of Florida, Gainesville, FL, USA Purpose: The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve...

  13. The East London glaucoma prediction score: web-based validation of glaucoma risk screening tool

    Science.gov (United States)

    Stephen, Cook; Benjamin, Longo-Mbenza

    2013-01-01

    AIM It is difficult for Optometrists and General Practitioners to know which patients are at risk. The East London glaucoma prediction score (ELGPS) is a web based risk calculator that has been developed to determine Glaucoma risk at the time of screening. Multiple risk factors that are available in a low tech environment are assessed to provide a risk assessment. This is extremely useful in settings where access to specialist care is difficult. Use of the calculator is educational. It is a free web based service. Data capture is user specific. METHOD The scoring system is a web based questionnaire that captures and subsequently calculates the relative risk for the presence of Glaucoma at the time of screening. Three categories of patient are described: Unlikely to have Glaucoma; Glaucoma Suspect and Glaucoma. A case review methodology of patients with known diagnosis is employed to validate the calculator risk assessment. RESULTS Data from the patient records of 400 patients with an established diagnosis has been captured and used to validate the screening tool. The website reports that the calculated diagnosis correlates with the actual diagnosis 82% of the time. Biostatistics analysis showed: Sensitivity = 88%; Positive predictive value = 97%; Specificity = 75%. CONCLUSION Analysis of the first 400 patients validates the web based screening tool as being a good method of screening for the at risk population. The validation is ongoing. The web based format will allow a more widespread recruitment for different geographic, population and personnel variables. PMID:23550097

  14. Penetration of sub-micron aerosol droplets in composite cylindrical filtration elements

    International Nuclear Information System (INIS)

    Geurts, Bernard J.; Pratte, Pascal; Stolz, Steffen; Stabbert, Regina; Poux, Valerie; Nordlund, Markus; Winkelmann, Christoph

    2011-01-01

    Advection-diffusion transport of aerosol droplets in composite cylindrical filtration elements is analyzed and compared to experimental data. The penetration, characterizing the fraction of droplets that passes through the pores of a filtration element, is quantified for a range of flow rates. The advection-diffusion transport in a laminar Poiseuille flow is treated numerically for slender pores using a finite difference approach in cylindrical coordinates. The algebraic dependence of the penetration on the Peclet number as predicted theoretically, is confirmed by experimental findings at a variety of aspect ratios of the cylindrical pores. The effective penetration associated with a composite filtration element consisting of a set of parallel cylindrical pores is derived. The overall penetration of heterogeneous composite filtration elements shows an algebraic dependence to the fourth power on the radii of the individual pores that are contained. This gives rise to strong variations in the overall penetration in cases with uneven distributions of pore sizes, highly favoring filtration by the larger pores. The overall penetration is computed for a number of basic geometries, providing a point of reference for filtration design and experimental verification.

  15. Glaucoma: a brief update for 2017

    African Journals Online (AJOL)

    Abstract. Glaucoma is a complex condition of the eye and the second leading cause of blindness around the globe. It is an ... to a disease, trauma or drugs, or as being congenital in nature ..... as dry eyes, blurred vision, blepharitis and others.

  16. THE PRACTICAL SIGNIFICANCE OF GLAUCOMA INVESTIGATIONS

    African Journals Online (AJOL)

    more reliable and the more practical ones in a short, concise manner ... pathological changes in the affected eye'" This definition makes it clear ... having glaucoma; clear-cut clinical cases are excluded. So often ... be remembered that the provocative tests are helpful, but ... Make sure your Schiotz tonometer is standardized.

  17. Methylphenidate (Ritalin-associated Cataract and Glaucoma

    Directory of Open Access Journals (Sweden)

    Chao-Kung Lu

    2006-12-01

    Full Text Available Methylphenidate hydrochloride (Ritalin is the drug of choice for attention deficit hyperactivity disorder (ADHD. However, an association of Ritalin with glaucoma has been reported. We report a case of Ritalin-associated cataract and glaucoma. A 10-year-old boy was diagnosed with ADHD and had received methylphenidate hydrochloride, 60 mg/day for 2 years. He presented with blurred vision. Best-corrected visual acuity was 6/60 in both eyes. Ocular examinations revealed intraocular pressure (IOP of 30 mmHg under medication, dense posterior subcapsular opacity of lens, pale disc with advanced cupping, and marked constriction of visual field. Despite maximal anti-glaucomatous medication, IOP still could not be controlled. The patient then received combined cataract and glaucoma surgery. Visual acuity improved and IOP was within normal limits in both eyes postoperatively. Large dose of methylphenidate may cause cataract and glaucoma. The mechanism remains unclear. Doctors should be aware of the possible ocular side effects of methylphenidate.

  18. Molteno3 Implantation as Primary Glaucoma Surgery

    Directory of Open Access Journals (Sweden)

    Juha O. Välimäki

    2014-01-01

    Full Text Available Purpose. To determine the outcome of Molteno3 implantation as primary glaucoma surgery and to analyze the factors influencing the surgical outcome. Methods. This is a retrospective clinical study of 106 consecutive eyes (97 patients with no previous glaucoma surgery. Surgical failure was defined as an IOP > 21 mmHg or less than a 20% reduction below baseline, or IOP ≤ 5 mmHg, on two consecutive visits after 3 months follow-up, or reoperation for glaucoma or loss of light perception. Results. At the end of the follow-up (mean, 35 months; range, 12–71 months, the mean postoperative IOP (14.2 ± 4.4 mmHg was statistically significantly lower than the preoperative IOP (35.2 ± 9.7 mmHg (P<0.001. Life-table success rates were 97%, 94%, and 91% after follow-up of 12, 24, and 36 months, respectively. Success rate for an IOP ≤ 18 mmHg was 77% at the last visit. Success was not influenced by previous cataract surgery, sex, age, laser trabeculoplasty (LTP, preoperative IOP, or number of antiglaucoma medications. Forty-seven eyes had 66 postoperative complications. Conclusions. The primary Molteno3 implant provided significant IOP lowering with minimal and manageable complications in uncontrolled glaucoma. Neither previous cataract surgery nor LTP had any detrimental effect on surgical success.

  19. Glaucoma facomórfico y ultrabiomicroscopia

    Directory of Open Access Journals (Sweden)

    María Cristina González González

    2015-01-01

    Conclusiones: La ultrabiomicroscopia es un herramienta útil ya que permite una valoración completa del segmento anterior, aun en presencia de medios opacos y ayuda a determinar la relación del cristalino con las estructuras adyacentes y el probable mecanismo del glaucoma.

  20. Filtration characteristics of porous silicon carbide media

    International Nuclear Information System (INIS)

    Ahn, Byung Gil; Seo, Yong Chil; Yim, Sung Paal; Kim, Joon Hyung

    1991-01-01

    The characteristics of a filter such as clean filter pressure drop, filtering performance and filter drag variation with dust loading have been studied with fabricated SiC filter specimens in the laboratory and commercial ceramic filters. Several theoretical equations have been modified and applied to investigate such characteristics. To estimate the pressure drop of clean gas flow through a cylindrical porous filter, Forchheimer equation, which contains the terms of permeability and turbulent factor at a high velocity of gas, has been modified and tested with experimental data. The filtering efficiency was found to be above 99.9% and the penetration of dust decreased exponentially with dust loading. The pressure drop during filtration was measured and showed to increase exponentially with dust loading in the beginning because particles were intercepted and a cake layer was formed by structural properties of a filter. And then it increased in proportion as the cake layer thickened. The effect of dust deposition on the pressure drop could be explained theoretically using several characteristic parameters relevant to dust size, structure of filters and cake layer formation

  1. Childhood glaucoma surgery in the 21st Century

    Science.gov (United States)

    Papadopoulos, M; Edmunds, B; Fenerty, C; Khaw, P T

    2014-01-01

    Most children with glaucoma will require surgery in their lifetime, often in their childhood years. The surgical management of childhood glaucoma is however challenging, largely because of its greater potential for failure and complications as compared with surgery in adults. The available surgical repertoire for childhood glaucoma has remained relatively unchanged for many years with most progress owing to modifications to existing surgery. Although the surgical approach to childhood glaucoma varies around the world, angle surgery remains the preferred initial surgery for primary congenital glaucoma and a major advance has been the concept of incising the whole of the angle (circumferential trabeculotomy). Simple modifications to the trabeculectomy technique have been shown to considerably minimise complications. Glaucoma drainage devices maintain a vital role for certain types of glaucoma including those refractory to other surgery. Cyclodestruction continues to have a role mainly for patients following failed drainage/filtering surgery. Although the prognosis for childhood glaucoma has improved significantly since the introduction of angle surgery, there is still considerable progress to be made to ensure a sighted lifetime for children with glaucoma all over the world. Collaborative approaches to researching and delivering this care are required, and this paper highlights the need for more high-quality prospective surgical trials in the management of the childhood glaucoma. PMID:24924446

  2. Update on pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Okafor, Kingsley; Vinod, Kateki; Gedde, Steven J

    2017-03-01

    The present article reviews the clinical features and pathogenesis of pigment dispersion syndrome and pigmentary glaucoma and provides an update regarding their diagnosis and management. Newer imaging modalities including ultrasound biomicroscopy and anterior segment optical coherence tomography facilitate visualization of the iris concavity characteristic of eyes with pigment dispersion syndrome and pigmentary glaucoma. Patients with pigmentary glaucoma may be distinguished from those with other glaucoma types by the presence of typical symptoms, personality type, and patterns of diurnal intraocular pressure fluctuation. Although laser iridotomy has been shown to alter iris anatomy in pigmentary glaucoma, it is not proven to slow visual field progression. Multiple trials have validated the safety and efficacy of filtering surgery in treating pigmentary glaucoma, with fewer studies published on the role of micro-invasive glaucoma surgery. Literature from the review period has further defined the unique clinical characteristics of pigment dispersion syndrome and pigmentary glaucoma. Laser surgery has a limited role in the management of these entities, whereas trabeculectomy remains an acceptable first-line surgical treatment. Further studies are needed to define the potential application of the newer micro-invasive glaucoma procedures in pigmentary glaucoma.

  3. Avaliação dos tipos de glaucoma no serviço de oftalmologia da UNICAMP Evaluation of glaucoma types at the sector of ophthalmology - UNICAMP

    Directory of Open Access Journals (Sweden)

    Andréia Peltier Urbano

    2003-01-01

    Full Text Available OBJETIVO: Avaliar a freqüência dos tipos de glaucoma no Setor de Glaucoma do Hospital das Clínicas da Universidade Estadual de Campinas. MÉTODOS: Estudo transversal de 329 pacientes atendidos no Setor de Glaucoma da Universidade Estadual de Campinas entre 1 de outubro e 20 de dezembro de 2000, com avaliação dos tipos de glaucoma e conduta terapêutica. RESULTADOS: De 329 pacientes atendidos no Ambulatório de Glaucoma, 132 foram encaminhados ao ambulatório por suspeita de glaucoma (40,1% e 197 como glaucoma diagnosticado (59,9%. Dos 132 suspeitos de glaucoma, 90 (68,2% foram confirmados como tendo glaucoma e 42 (31,8% encontram-se em acompanhamento. Dos 329 pacientes avaliados, 283 (86% tinham glaucoma, 42 (12,8% suspeita de glaucoma, 2 (0,6% diagnóstico de glaucoma excluído e 2 (0,6% hipertensão ocular. Dos 530 olhos glaucomatosos, havia 298 (56,2% glaucomas primários de ângulo aberto, 108 (20,4% glaucomas primários de ângulo estreito, 21 (4% glaucomas pós-facectomia, 19 (3,6% glaucomas congênitos e 16 (3% glaucomas de pressão normal. A conduta terapêutica adotada foi inicialmente clínica em todos os casos. Após seguimento médio de 10,5 meses, 89 (16,8% olhos necessitaram tratamento com laser: 72 (13,6% iridotomias, 7 (1,3% trabeculoplastias e 10 (1,9% panfotocoagulações. Cento e setenta e cinco olhos (33% foram submetidos a tratamento cirúrgico. CONCLUSÃO: O tipo mais freqüente de glaucoma observado foi o glaucoma primário de ângulo aberto, seguido por glaucoma primário de ângulo estreito. Glaucomas como o de pressão normal e o pseudo-exfoliativo foram pouco freqüentes na população estudada.PURPOSE: To evaluate the frequency of different types of glaucoma at the Hospital das Clínicas of Campinas State University. METHODS: Cross-sectional study of 329 patients followed at the Glaucoma Service of Campinas State University from October 1 to December 20, 2000. The frequency of each type of glaucoma and the

  4. Detecção de maculopatia hipotônica subclínica pelo OCT III após cirurgia filtrante Detection of subclinical hypotony maculopathy with OCT III after filtration surgery

    Directory of Open Access Journals (Sweden)

    Mônica Weyll

    2006-12-01

    Full Text Available OBJETIVO: Detectar possíveis sinais de maculopatia hipotônica subclínica por meio da OCT III em pacientes submetidos à cirurgia filtrante. MÉTODOS: Pacientes que realizaram procedimento cirúrgico filtrante com pressão intra-ocular menor que 9 mmHg submeteram-se ao exame OCT III. RESULTADOS: Sete (87,50% pacientes apresentaram diagnóstico prévio de glaucoma crônico simples e 1 (12,50% de glaucoma agudo de ângulo fechado. Apenas duas pacientes (25,00% apresentaram maculopatia hipotônica detectada pela OCT III. CONCLUSÃO: A OCT III parece ser um bom método diagnóstico de maculopatia hipotônica subclínica em pacientes submetidos à cirurgia filtrante convencional.PURPOSE: To detect nondiagnostic hypotony maculopathy by OCT III after filtration surgery. METHODS: After surgery, patients with intraocular pressure less than 9 mmHg were submitted to OCT III examination. RESULTS: Seven (87.50% patients with previous diagnosis of open angle glaucoma and one (12.50% of them with acute angle closure glaucoma. Two patients (25.00% presented hypotony maculopathy on OCT III examination. CONCLUSION: OCT III examination seems to be a good diagnostic method to detect subclinical hypotony maculopathy after filtration surgery.

  5. A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

    International Nuclear Information System (INIS)

    Kim, Kyoung Hwan; Kim, Byeong Hee; Seo, Young Ho

    2012-01-01

    This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system. (paper)

  6. Latanoprost ophthalmic solution in the treatment of open angle glaucoma or raised intraocular pressure: a review

    Directory of Open Access Journals (Sweden)

    Andrea Russo

    2009-01-01

    Full Text Available Andrea Russo, Ivano Riva, Teodoro Pizzolante, Federico Noto, Luciano QuarantaCattedra di Malattie dell’Apparato Visivo, Università degli studi di Brescia, USVD “Centro per lo studio del Glaucoma” Spedali Civili di BresciaAbstract: Latanoprost is a prostaglandin F2-alpha isopropyl ester prodrug which is rapidly hydrolyzed by esterases in the cornea to the biologically active latanoprost acid. When latanoprost is topically administered into the eye, the cornea seems to act like as a slow-release depot to the anterior segment. One hour after administration maximum concentration is found in the iris, followed by the anterior chamber and the ciliary body. Despite extensive research, controversy remains about the real mechanism of action of this drug. Immunohistochemical data have shown that the intraocular pressure (IOP reduction with topical prostaglandin F2-alpha is associated with a reduction of collagens within the uveoscleral outflow pathway. Evidence from several experimental and clinical studies suggests that latanoprost is a valuable addition first-line treatment alternatives for glaucoma, ocular hypertension and even angle-closure glaucoma. Strong points are its efficacy, which is demonstrated to be higher than that of brimonidine, dorzolamide and timolol with fewer systemic adverse effects; a convenient administration schedule; and the IOP-controlling pattern, which is relatively flat compared with timolol and dorzolamide, and enables better control in glaucoma progression, since large fluctuations may be associated with the risk of developing glaucoma in untreated ocular hypertensive subjects.Keywords: latanoprost, intraocular pressure, glaucoma, ocular hypertension

  7. Evaluation of the tightness of contact between 
limbal sclera tunnel and tube following Ahmed 
glaucoma valve implantation.

    Science.gov (United States)

    Holló, Gábor; Naghizadeh, Farzaneh

    2013-01-01

    To investigate whether the tightness of contact between the tube and the limbal sclera tunnel can be evaluated with high-magnification anterior segment optical coherence tomography (OCT) imaging following Ahmed glaucoma valve implantation. Tightness between the tube and the limbal sclera tunnel was investigated with the CAM-L cornea lens adapter of the Optovue Fourier-domain OCT (RTVue-OCT) for 21 uncomplicated Ahmed glaucoma valves implanted in 20 eyes of 19 patients with glaucoma. Nineteen valves were implanted 4 to 124 months earlier (late postoperative cases) and 2 valves 1 day prior to the imaging (early postoperative cases). All valves were introduced into the anterior chamber via a limbal sclera tunnel. The limbal intratunnel part of the tube was successfully imaged in all but 2 cases where an additional full-thickness sclera patch was used. In 14 cases, the contact was tight without tube compression. In 
5 cases, the tube was partially compressed but remained open in the limbal sclera tunnel, and redilated behind the limbus. No case with loose contact or peritubular filtration was seen. The posterior run of the tube was successfully imaged in all 19 cases without a full-thickness sclera patch. High-magnification imaging with the CAM- L anterior segment adapter of the RTVue-OCT allows detailed examination of the limbal insertion area of tubes in both the early and late postoperative periods. Therefore this method may potentially be applied for detection of complications related to tube insertion after glaucoma drainage device surgery.

  8. Projective Dimension in Filtrated K-Theory

    DEFF Research Database (Denmark)

    Bentmann, Rasmus Moritz

    2013-01-01

    Under mild assumptions, we characterise modules with projective resolutions of length n∈N in the target category of filtrated K-theory over a finite topological space in terms of two conditions involving certain Tor -groups. We show that the filtrated K-theory of any separable C∗dash-algebra over...... any topological space with at most four points has projective dimension 2 or less. We observe that this implies a universal coefficient theorem for rational equivariant KK-theory over these spaces. As a contrasting example, we find a separable C∗dash-algebra in the bootstrap class over a certain five......-point space, the filtrated K-theory of which has projective dimension 3. Finally, as an application of our investigations, we exhibit Cuntz-Krieger algebras which have projective dimension 2 in filtrated K-theory over their respective primitive spectrum....

  9. Filtration aids in uranium ore processing

    International Nuclear Information System (INIS)

    Ford, H.L.; Levine, N.M.; Risdon, A.L.

    1975-01-01

    The patent describes a process whereby improved flocculation efficiency and filtration of carbonate leached uranium ore pulps are obtained by treating the filter feed slurry with an aqueous solution of hydroxyalkyl guar. (J.R.)

  10. Determination of the filtration velocities and mean velocity in ground waters using radiotracers

    International Nuclear Information System (INIS)

    Duran P, Oscar; Diaz V, Francisco; Heresi M, Nelida

    1994-01-01

    An experimental method to determine filtration, or, Darcy velocity and mean velocity in underground waters using radiotracers, is described. After selecting the most appropriate tracers, from 6 chemical compounds, to measure water velocity, a method to measure filtration velocity was developed. By fully labelling the water column with 2 radioisotopes, Br and tritium, almost identical values were obtained for the aquifer filtration velocity in the sounding S1. This value was 0.04 m/d. Field porosity was calculated at 11% and mean velocity at 0.37 m.d. With the filtration velocity value and knowing the hydraulic variation between the soundings S1 and S2 placed at 10 meters, field permeability was estimated at 2.4 x 10 m/s. (author)

  11. Glaucoma and cataract surgery: two roads merging into one.

    Science.gov (United States)

    Shah, Manjool; Law, Geoffrey; Ahmed, Iqbal Ike K

    2016-01-01

    To discuss the increasing utilization of cataract extraction in the management of glaucoma and to highlight advances in surgical care that can promote synergistic treatment of these comorbid conditions. Recent years have demonstrated significant advances in the management of glaucoma through the use of novel microinvasive glaucoma devices. Furthermore, an increased understanding of the role of cataract surgery in the treatment of various glaucomas warrants review. Nevertheless, cataract surgery in the glaucoma patient warrants specific preoperative, intraoperative, and postoperative planning to optimize visual function and quality of life while mitigating potential risk factors for adverse events. Although the challenges of performing cataract extraction on glaucoma patients exist, the potential benefit to these patients is substantial. With attention to pre- and perioperative surgical planning and intraoperative technique, as well as with awareness and potential utilization of novel devices and treatment strategies, cataract extraction offers a unique platform for anatomical and functional improvement in this increasingly common cohort of patients.

  12. Alternative therapy in glaucoma management: Is there any role?

    Directory of Open Access Journals (Sweden)

    Parikh Rajul

    2011-12-01

    Full Text Available Glaucoma is one of the leading causes of blindness worldwide. Various randomized controlled clinical trials have shown that lowering intraocular pressure (IOP does reduce progression of primary open-angle glaucoma. However, there is lots of interest in nonpharmacological options that includes lifestyle adjustment and alternative and complementary therapy (ACT. At least 5% glaucoma population uses ACT. Various lifestyle activities like exercise and alcohol can reduce IOP by 1 to 2 mm Hg but would have small effect on glaucoma. The psychological stress can increase IOP. Hypothetically and few studies do show neuroprotective effect (or effect on ocular blood flow of alcohol, Gingko biloba, bilberry, but the current evidence is weak for its routine use. We must also remember the side effects of ′medications′ (e.g., marijuana, alcohol before promoting as remedy for glaucoma. In current armamentarium of glaucoma management, ACT cannot substitute the conventional treatment available to lower IOP.

  13. Cyclo-photocoagulation in the management of aphakic glaucoma

    International Nuclear Information System (INIS)

    Lee, P.-F.

    1984-01-01

    Transpupillary argon laser photocoagulation of the ciliary processes (TALC) through a widely dilated pupil, with or without cerebral depression, has been used in the management of glaucoma in aphakic eyes for a number of years. 58% of glaucoma in aphakics treated with TALC showed sustained and meaningful intraocular pressure reduction 2 months to 5 years after the procedure. Clinically, the TALC procedure is a relatively safe, effective, and an useful alternative approach in the management of selected cases of glaucoma in aphakics. (Auth.)

  14. Superior versus inferior Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi

    2009-02-01

    To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5glaucoma surgery, phthisis bulbi, or loss of light perception. Of a total of 106 eyes, 58 and 48 eyes underwent AGV implantation in the superior and inferior quadrants, respectively. Baseline characteristics were comparable in the study groups, except for preoperative IOP, which was higher in the superior group (P = 0.01). Patients were followed for a mean period of 10.6+/-8.49 months and 10.58+/-6.75 months in the superior and inferior groups, respectively (P = 0.477). BCVA was comparable between the groups at all postoperative visits (P>0.122). After 1 year, statistically significant but comparable IOP reduction from baseline (Pglaucoma medications was comparable after 1 year (1.3+/-1.2 vs. 1.9+/-0.8 for superior and inferior implants, respectively, P = 0.256). Success rates were also similar at 1 year: 27 eyes (81.8%) versus 20 eyes (95.2%) for superior and inferior implants, respectively (P = 0.227). However, the overall rate of complications, such as implant exposure necessitating removal, cosmetically unappealing appearance, and endophthalmitis, was higher in the inferior group: 12 eyes (25%) versus 3 eyes (5.2%) for superior and inferior groups, respectively, (P = 0.004). Superior and inferior AGV implants have similar intermediate efficacy in terms of IOP reduction, decrease in number of glaucoma medications, and preservation of vision. However

  15. Combined Phacoemulsification and Ahmed Glaucoma Drainage Implant Surgery for Patients With Refractory Glaucoma and Cataract.

    Science.gov (United States)

    Valenzuela, Felipe; Browne, Andrew; Srur, Miguel; Nieme, Carlos; Zanolli, Mario; López-Solís, Remigio; Traipe, Leonidas

    2016-02-01

    To examine the indications, safety, efficacy, and complications of combined phacoemulsification and Ahmed glaucoma drainage implant surgery. A retrospective case review of 35 eyes (31 patients) subjected to combined phacoemulsification and Ahmed glaucoma drainage implant surgery. Demographic characteristics of the study population, indications for combined surgery, and operative and postoperative complications were recorded. Visual acuity, intraocular pressure (IOP), and number of glaucoma medications were evaluated preoperatively and postoperatively. Complete success was defined as IOP ≤ 21 mm Hg without medication, qualified success if IOP ≤ 21 mm Hg with ≥ 1 medications, and failure if IOP>21 mm Hg or ≤ 5 mm Hg on ≥ 2 consecutive visits. Mean follow-up was 29.5 months (range, 6 to 87 mo). The most common indication for combined surgery was a history of prior failed trabeculectomy (60%). Postoperative visual acuity improved in 30 of 35 eyes (85%) (PAhmed glaucoma drainage implant surgery seems to be a safe and effective surgical option, providing good visual rehabilitation and control of IOP for patients with refractory glaucoma and cataract.

  16. Particle clogging in porous media. Filtration of a smectite solution

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Tobias (Chalmers University of Technology, Goeteborg (Sweden))

    2010-01-15

    The goal of this project is to find out if it is possible for bentonite clay to self heal during leaching with deionized water. The investigation has focused on the formation of a filter cake made of accessory material from MX 80 and the separation of solid material when a smectite solution (1%) is pushed through the cake using a pressure difference of 5 bar. It was also in the scope of this project to design and build the necessary equipment for these experiments. In the literature review it was not found any example that the phenomenon of clogging has been used as a self-healing method previously. It was rather separated also between the clogging of a filter cake (deep bed filtration or cake filtration) and the filtration of colloidal particles. Probably because the latter are in such low concentrations in natural systems and the focus have mainly been in the transport properties of colloids within a filter cake or deep bed filter. An experimental equipment was designed and built. It consists of seven filtration cells that could operate in parallel. All of them are connected to the same source of pressure to ensure equal conditions. A system was also prepared to prevent air from dissolving in the solution because it could create an unwanted expansion in the filter cake due to lower solubility at lower pressure. The experiment showed good separation of smectite particles from the solution when it passed through the filter cake. In all tested cases, the separation was almost complete after long enough time, indicating that the cake has small enough pores to act as a geometrical hinder for the small particles. Comparison between the materials prepared at Chalmers University of Technology and at Clay Technology showed a very good agreement indicating similar properties of the produced smectite

  17. Particle clogging in porous media. Filtration of a smectite solution

    International Nuclear Information System (INIS)

    Richards, Tobias

    2010-01-01

    The goal of this project is to find out if it is possible for bentonite clay to self heal during leaching with deionized water. The investigation has focused on the formation of a filter cake made of accessory material from MX 80 and the separation of solid material when a smectite solution (1%) is pushed through the cake using a pressure difference of 5 bar. It was also in the scope of this project to design and build the necessary equipment for these experiments. In the literature review it was not found any example that the phenomenon of clogging has been used as a self-healing method previously. It was rather separated also between the clogging of a filter cake (deep bed filtration or cake filtration) and the filtration of colloidal particles. Probably because the latter are in such low concentrations in natural systems and the focus have mainly been in the transport properties of colloids within a filter cake or deep bed filter. An experimental equipment was designed and built. It consists of seven filtration cells that could operate in parallel. All of them are connected to the same source of pressure to ensure equal conditions. A system was also prepared to prevent air from dissolving in the solution because it could create an unwanted expansion in the filter cake due to lower solubility at lower pressure. The experiment showed good separation of smectite particles from the solution when it passed through the filter cake. In all tested cases, the separation was almost complete after long enough time, indicating that the cake has small enough pores to act as a geometrical hinder for the small particles. Comparison between the materials prepared at Chalmers University of Technology and at Clay Technology showed a very good agreement indicating similar properties of the produced smectite

  18. Childhood glaucoma profile in Dakahelia, Egypt: a retrospective study

    Directory of Open Access Journals (Sweden)

    Tharwat H. Mokbel

    2018-04-01

    Full Text Available AIM: To analyze childhood glaucoma regarding its demographics, presentations, different causes and surgical modalities used among patients in Dakahelia and to apply the Childhood Glaucoma Research Network (CGRN classification retrospectively to evaluate its convenience. METHODS: A retrospective study in which the medical files of all glaucoma patients <16 years old presented to Mansoura Ophthalmic Center, Mansoura University from 2014 to 2017, were retrieved and analyzed. Collected data included: age, gender, laterality, visual acuity (VA, refraction, intraocular pressure (IOP, corneal diameter, cup-disc ratio, types and number of surgeries and antiglaucomatous drugs (AGD at the first and last visit. Prevalence of different subtypes was calculated and means of clinical features were compared. RESULTS: A total of 305 eyes of 207 patients were included classified into 6 groups: primary congenital glaucoma (PCG, juvenile open angle glaucoma (JOAG, glaucoma associated with systemic disease, glaucoma associated with ocular anomalies, acquired glaucoma and glaucoma following cataract surgery. PCG was the predominant type (55.1% followed by acquired glaucoma (29.5%. Males represented 63.8% of the whole studied patients. Glaucoma associated with ocular anomaly group showed the youngest age at diagnosis (21.9±30.0mo. The shortest corneal diameter was recorded in post cataract group (10.4±0.5 mm. Highest cup-disc ratio was found in the PCG group (P<0.0005. Glaucoma associated with systemic disease presented with the highest baseline IOP (34.5±5.0 mm Hg. All the cases with PCG were treated surgically with 21.8% required more than one surgery. The majority of the patients (74.2% in the acquired group were treated medically. Combined trabeculotomy-trabeculectomy was the most frequent operation done, accounting for 34.5% of all primary surgeries. Ahmed valve implantation comprised 87% of the secondary surgeries. Acquired glaucoma group had the highest

  19. Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2016-09-01

    Full Text Available Glaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum tolerable medications. Details of the glaucoma surgical management of these patients as well as their postoperative care and pregnancy and clinical outcomes on longitudinal follow-up are discussed. All 3 patients had juvenile open-angle glaucoma and were on various anti-glaucoma medications, including oral acetazolamide. The first case described underwent trabeculectomy without antimetabolites in both eyes because of uncontrolled intraocular pressure with topical medications. The surgery was done with topical lidocaine jelly and subconjunctival lidocaine during the second and third trimesters. The second patient had an Ahmed valve implantation in both eyes during the second and third trimesters because of uncontrolled IOP with topical medications and no response to selective laser trabeculoplasty. Surgery was done with topical tetracaine and subconjunctival and sub-Tenon’s lidocaine. The third case had a Baerveldt valve implantation under general anesthesia in the second trimester. In selected pregnant glaucoma patients with medically uncontrolled intraocular pressure threatening vision, incisional surgery may lead to good outcomes for the patient with no risk for the fetus.

  20. Relationship between retinal lattice degeneration and open angle glaucoma.

    Science.gov (United States)

    Rahimi, Mansour

    2005-01-01

    Patients with retinal disorders may develop glaucoma of both a primary and secondary type. Pigment may contribute to trabecular obstruction in some patients with open-angle glaucoma. Lattice degeneration of the retina in its typical form is a sharply demarcated, circumferentially oriented, degenerative process with significant alterations of retinal pigmentation. The association between myopia, open angle glaucoma and pigment dispersion is striking. Therefore, it could be postulated that there is significant prevalence of open angle glaucoma in patients with retinal lattice degeneration, especially in combination with myopia.

  1. Pigment dispersion syndrome and pigmentary glaucoma--a major review.

    Science.gov (United States)

    Niyadurupola, Nuwan; Broadway, David C

    2008-12-01

    Pigment dispersion syndrome (PDS) is an interesting condition that can lead to secondary open angle glaucoma. Pigmentary glaucoma is primarily a disease of young people, myopes and men. PDS is characterized by the presence of Krukenberg spindles, iris trans-illumination defects, trabecular meshwork pigmentation and backward bowing of the iris. Posterior bowing of the iris causes rubbing of the pigmented iris epithelium against lens structures, liberation of pigment and trabecular meshwork changes that result in reduced aqueous outflow with the risk of glaucoma. Peripheral laser iridotomy can reverse backward bowing of the iris and may prevent progression of pigmentary glaucoma.

  2. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey

    Directory of Open Access Journals (Sweden)

    Daniel E. Grigera

    2013-06-01

    Full Text Available PURPOSE: The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. METHODS: An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1 and diagnosis (Part 2 of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. RESULTS: Fifty participants from 14 countries completed the questionnaire. For the medical treatment of glaucoma, nearly all respondents (98% or greater confirmed that medical treatment as first-line therapy is preferred to surgery, prostaglandin analogs are the medication of first choice for primary open-angle glaucoma (POAG, longitudinal monitoring of efficacy should include intraocular pressure, structural and functional status, as well as if patients' quality of life is impaired by the high cost of medication. For the diagnosis of glaucoma section, all respondents confirmed that, after initial examination, gonioscopy should be repeated over time, standard automated perimetry is the most important functional examination for diagnosis and monitoring of primary open-angle glaucoma, central corneal thickness is important in assessment of glaucoma, and computerized imaging tests help in clinical evaluation of optic disc. CONCLUSIONS: This survey shows a high level of agreement on most aspects of glaucoma diagnosis and treatment among Latin American glaucoma experts. Areas of disagreement highlight the need for further evidence or education. These findings will be useful for guiding future efforts to optimize glaucoma practice by clinicians in Latin America.

  3. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey.

    Science.gov (United States)

    Grigera, Daniel E; Mello, Paulo Augusto Arruda; Barbosa, Wilma Lelis; Casiraghi, Javier Fernando; Grossmann, Rodolfo Perez; Peyret, Alejo

    2013-01-01

    The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1) and diagnosis (Part 2) of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. Fifty participants from 14 countries completed the questionnaire. For the medical treatment of glaucoma, nearly all respondents (98% or greater) confirmed that medical treatment as first-line therapy is preferred to surgery, prostaglandin analogs are the medication of first choice for primary open-angle glaucoma (POAG), longitudinal monitoring of efficacy should include intraocular pressure, structural and functional status, as well as if patients' quality of life is impaired by the high cost of medication. For the diagnosis of glaucoma section, all respondents confirmed that, after initial examination, gonioscopy should be repeated over time, standard automated perimetry is the most important functional examination for diagnosis and monitoring of primary open-angle glaucoma, central corneal thickness is important in assessment of glaucoma, and computerized imaging tests help in clinical evaluation of optic disc. This survey shows a high level of agreement on most aspects of glaucoma diagnosis and treatment among Latin American glaucoma experts. Areas of disagreement highlight the need for further evidence or education. These findings will be useful for guiding future efforts to optimize glaucoma practice by clinicians in Latin America.

  4. 40 CFR 141.719 - Additional filtration toolbox components.

    Science.gov (United States)

    2010-07-01

    ... taken from a surface water or GWUDI source. A cap, such as GAC, on a single stage of filtration is not... separate stage of filtration if both filtration stages treat entire plant flow taken from a surface water... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Additional filtration toolbox...

  5. Pattern-reversal electroretinograms in unilateral glaucoma.

    Science.gov (United States)

    Wanger, P; Persson, H E

    1983-06-01

    Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means from glaucomatous and opposite eyes was statistically significant. No differences were observed in flash ERGs or OPs. The histopathologic correlate to the visual field defects in glaucoma is retinal ganglion cell degeneration. The present electrophysiologic findings support the view, based on results from animal experiments, that the pattern-reversal ERG reflects ganglion cell activity.

  6. Pigmentary glaucoma accompanied by Usher syndrome.

    Science.gov (United States)

    Koucheki, Behrooz; Jalali, Kamran Hodjat

    2012-08-01

    To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.

  7. Glaucoma progression detection with frequency doubling technology (FDT) compared to standard automated perimetry (SAP) in the Groningen Longitudinal Glaucoma Study.

    Science.gov (United States)

    Wesselink, Christiaan; Jansonius, Nomdo M

    2017-09-01

    To determine the usefulness of frequency doubling perimetry (FDT) for progression detection in glaucoma, compared to standard automated perimetry (SAP). Data were used from 150 eyes of 150 glaucoma patients from the Groningen Longitudinal Glaucoma Study. After baseline, SAP was performed approximately yearly; FDT every other year. First and last visit had to contain both tests. Using linear regression, progression velocities were calculated for SAP (Humphrey Field Analyzer) mean deviation (MD) and FDT MD and the number of test locations with a total deviation probability below p glaucoma progression in patients who cannot perform SAP reliably. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  8. Dynamic tube movement after reimplantation of Ahmed glaucoma valve in a child with glaucoma in aphakia

    Science.gov (United States)

    Senthil, Sirisha; Badakare, Akshay

    2014-01-01

    A 10-year-old girl underwent an Ahmed glaucoma valve (AGV) implantation as a primary procedure for glaucoma in aphakia due to congenital cataract surgery. Following an unintended accidental excision of AGV tube during bleb revision for hypertensive phase, AGV was explanted and a second AGV was implanted in the same quadrant after 2 weeks. This resulted in a rare complication of dynamic tube movement in the anterior chamber with tube corneal touch and localised corneal oedema. Excision of the offending unstable tube and placement of a paediatric AGV in a different quadrant led to resolution of this complication, stable vision and well-controlled intraocular pressure. This case highlights the possible causes of dynamic tube, related complications and its management. This case also highlights the importance of understanding the various physiological phases after glaucoma drainage device implantation and their appropriate management. PMID:24695662

  9. Hypothyroidism and Glaucoma in The United States

    Science.gov (United States)

    Kakigi, Caitlin; Kasuga, Toshimitsu; Wang, Sophia Y.; Singh, Kuldev; Hiratsuka, Yoshimune; Murakami, Akira; Lin, Shan C.

    2015-01-01

    Purpose To investigate the association between hypothyroidism and glaucomatous disease. Methods This cross-sectional study included all subjects above the age of 40 years from two nationwide surveys: the 2008 National Health Interview Survey (NHIS) as well as the 2007 and 2008 National Health and Nutrition Examination Survey (NHANES). The presence or absence of glaucoma, thyroid disease and other demographic and health-related information including comorbidities was ascertained via interview. Blood samples were collected from NHANES subjects and analyzed for thyrotropin (TSH). Results A total of 13,599 and 3,839 NHIS and NHANES participants respectively were analyzed to assess for a possible relationship between self-reported glaucoma, and self-reported hypothyroidism as well as self-reported thyroid disease. The unadjusted odds ratio (OR) for NHIS showed a significant association between self-reported glaucoma and self-reported hypothyroidism (OR 1.46, 95% confidence interval [CI] 1.07-1.99). Multivariate logistic regression analysis adjusted for age, gender, race, comorbidities, and health-related behavior, however, showed no association between self-reported glaucoma and hypothyroidism or thyroid disease in both surveys (OR 1.60, 95%CI 0.87-2.95 for NHIS; OR 1.05, 95%CI 0.59-1.88 for NHANES). Conclusion A previously reported association between hypothyroidism and glaucomatous disease was not confirmed in two large U.S. health survey populations. While such an association was noted in the univariate analysis for the NHIS survey, such a relationship was not found in the multivariate analysis after adjustment for potential confounding variables. PMID:26230664

  10. Anesthetic Preconditioning as Endogenous Neuroprotection in Glaucoma

    Directory of Open Access Journals (Sweden)

    Tsung-Han Chou

    2018-01-01

    Full Text Available Blindness in glaucoma is the result of death of Retinal Ganglion Cells (RGCs and their axons. RGC death is generally preceded by a stage of reversible dysfunction and structural remodeling. Current treatments aimed at reducing intraocular pressure (IOP are ineffective or incompletely effective in management of the disease. IOP-independent neuroprotection or neuroprotection as adjuvant to IOP lowering in glaucoma remains a challenge as effective agents without side effects have not been identified yet. We show in DBA/2J mice with spontaneous IOP elevation and glaucoma that the lifespan of functional RGCs can be extended by preconditioning RGCs with retrobulbar lidocaine in one eye at four months of age that temporary blocks RGC axonal transport. The contralateral, PBS-injected eye served as control. Lidocaine-induced impairment of axonal transport to superior colliculi was assessed by intravitreal injection of cholera toxin B. Long-term (nine months effect of lidocaine were assessed on RGC electrical responsiveness (PERG, IOP, expression of relevant protein (BDNF, TrkB, PSD95, GFAP, Synaptophysin, and GAPDH and RGC density. While lidocaine treatment did not alter the age-related increase of IOP, TrkB expression was elevated, GFAP expression was decreased, RGC survival was improved by 35%, and PERG function was preserved. Results suggest that the lifespan of functional RGCs in mouse glaucoma can be extended by preconditioning RGCs in early stages of the disease using a minimally invasive treatment with retrobulbar lidocaine, a common ophthalmologic procedure. Lidocaine is inexpensive, safe and is approved by Food and Drug Administration (FDA to be administered intravenously.

  11. Longitudinal-transverse liquid filtration in an annular heat-liberating medium

    International Nuclear Information System (INIS)

    Akhramovich, A.P.; Kolos, V.P.; Sorokin, V.N.

    1987-01-01

    The authors interpret experimental flow visualization data and construct a flow model for coolant filtration and flow in a layered granular heat exchange material for implementation in a reactor cooling system. Breakaway flow zones close to the ends of a layer in longitudinal-transverse liquid filtration are observed. In a linear approximation the problem of determining the form of the ends of the layer for which there is no flow breakaway is solved. The model is tested against experimental data for water and a nitrogen tetroxide coolant

  12. Effect of phacoemulsification on intraocular pressure in patients with primary open angle glaucoma and pseudoexfoliation glaucoma

    Directory of Open Access Journals (Sweden)

    Jesus Jimenez-Roman

    2017-09-01

    Full Text Available AIM: To compare the effect of phacoemulsification on intraocular pressure (IOP in patients with primary open angle glaucoma (POAG and pseudoexfoliation glaucoma (PXG. METHODS: A retrospective comparative case series conducted at the Glaucoma Department at the Association to Prevent Blindness in Mexico. The study enrolled consecutive patients having phacoemulsification with intraocular lens (IOL implantation and a diagnosis of POAG or PXG. Data about IOP values and number of glaucoma medications used was collected at baseline, 1, 3, 6 and 12mo postoperatively. RESULTS: The study enrolled 88 patients (88 eyes. After phacoemulsification, there was a statistically significant reduction in IOP values and glaucoma medications use compared to baseline in both POAG and PXG patients (P<0.001. In the POAG group, a 20% decrease in IOP values was evidenced, and a 56.5% reduction in the number of medications used at the one-year follow-up. The PXG group showed a 20.39%, and a 34.46% decrease in IOP and number of medications used, respectively. A significant difference in the mean ΔIOP (postoperative changes in IOP was evidenced between groups (P=0.005. The reduction of the postsurgical IOP mean values in both groups, the POAG group showed a greater reduction in IOP values compared to the PXG group. CONCLUSION: In both types of glaucoma, phacoemulsification cataract surgery can result in a significant IOP reduction (20% over a 12mo follow-up period. The number of medications used is also significantly reduced up to 12mo after surgery, especially in the PXG group.

  13. Surgical outcomes of trabeculectomy and glaucoma drainage implant for uveitic glaucoma and relationship with uveitis activity.

    Science.gov (United States)

    Kwon, Hye Jin; Kong, Yu Xiang George; Tao, Lingwei William; Lim, Lyndell L; Martin, Keith R; Green, Catherine; Ruddle, Jonathan; Crowston, Jonathan G

    2017-07-01

    This study provides ophthalmologists who manage uveitic glaucoma with important information on factors that can affect the success of surgical management of this challenging disease. This study examines surgical outcomes of trabeculectomy and glaucoma device implant (GDI) surgery for uveitic glaucoma, in particular the effect of uveitis activity on surgical outcomes. Retrospective chart review at a tertiary institution. Eighty-two cases with uveitic glaucoma (54 trabeculectomies and 28 (GDI) surgeries) performed between 1 December 2006 and 30 November 2014. Associations of factors with surgical outcomes were examined using univariate and multivariate analysis. Surgical outcomes as defined in Guidelines from World Glaucoma Association. Average follow up was 26.4 ± 21.5 months. Overall qualified success rate of the trabeculectomies was not statistically different from GDI, being 67% and 75%, respectively (P = 0.60). Primary and secondary GDI operations showed similar success rates. The most common postoperative complication was hypotony (~30%). Active uveitis at the time of operation was higher in trabeculectomy compared with GDI group (35% vs. 14%). Active uveitis at the time of surgery did not significantly increase risk of failure for trabeculectomies. Recurrence of uveitis was significantly associated with surgical failure in trabeculectomy group (odds ratio 4.8, P = 0.02) but not in GDI group. Surgical success rate of GDI was not significantly different from trabeculectomy for uveitic glaucoma in this study. Regular monitoring, early and prolonged intensive treatment of ocular inflammation is important for surgical success particularly following trabeculectomy. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  14. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  15. Glaucoma in Costa Rica: Initial approaches

    Directory of Open Access Journals (Sweden)

    Gabriela Chavarría-Soley

    2004-09-01

    Full Text Available Glaucoma is the second most frequent cause of irreversible blindness worldwide. Genetic factors have been implicated in the development of the disease. So far six loci (GLC1A-GLC1F and two genes (TIGR/MYOC and OPTN are involved in the development of juvenile (JOAG and adult onset or chronic primary open angle glaucoma (COAG, while two loci (GLC3A,GLC3B and one gene (CYP1B1 are known for primary congenital glaucoma (PCG. Here we summarize the results of the first genetic studies of glaucoma in Costa Rica. Nine families: 1 with JOAG, 1 with PCG and 7 with COAG were screened for mutations at the known genes. A10 bp duplication, 1546-1555dupTCATGCCACC, at the CYP1B1 gene, causes, in homozygous state, glaucoma in the consanguineous PCG family. This mutation has been found in different countries and generates an early stop codon that termitates protein synthesis 140 amino acids earlier than the normal allele. In exon 1 of the TIGR/MYOC the innocuous Arg76Lys variant was found in two of the COAG families. In the OPTN gene two variants in the coding region (Thr34Thr, Met 98Lys and 7 intronic changes were found in other Costa Rican glaucoma patients. One of the COAG families was chosen for a genome scan with 379 microsatellite markers and linkage analysis. LOD scores "suggestive" of linkage were obtained for several chromosomal regions. Evidence indicates that hereditary glaucoma in Costa Rica is highly heterogeneous and that further studies in the country will probably disclose some up to now unknown genes responsible for the disease. Rev. Biol. Trop. 52(3: 507-520. Epub 2004 Dic 15.El glaucoma es la segunda causa de ceguera irreversible en el mundo. El componente genético de algunos de los distintos tipos ha sido demostrado: seis loci (GLC1A-GLC1F y dos genes (TIGR/MYOC y OPTN se conocen, hasta ahora, como responsables de la aparición de glaucomas primarios de ángulo abierto tanto del tipo juvenil (JOAG como de l tipo de adultos (COAG. Además, dos

  16. Automatic CDR Estimation for Early Glaucoma Diagnosis

    Science.gov (United States)

    Sarmiento, A.; Sanchez-Morillo, D.; Jiménez, S.; Alemany, P.

    2017-01-01

    Glaucoma is a degenerative disease that constitutes the second cause of blindness in developed countries. Although it cannot be cured, its progression can be prevented through early diagnosis. In this paper, we propose a new algorithm for automatic glaucoma diagnosis based on retinal colour images. We focus on capturing the inherent colour changes of optic disc (OD) and cup borders by computing several colour derivatives in CIE L∗a∗b∗ colour space with CIE94 colour distance. In addition, we consider spatial information retaining these colour derivatives and the original CIE L∗a∗b∗ values of the pixel and adding other characteristics such as its distance to the OD centre. The proposed strategy is robust due to a simple structure that does not need neither initial segmentation nor removal of the vascular tree or detection of vessel bends. The method has been extensively validated with two datasets (one public and one private), each one comprising 60 images of high variability of appearances. Achieved class-wise-averaged accuracy of 95.02% and 81.19% demonstrates that this automated approach could support physicians in the diagnosis of glaucoma in its early stage, and therefore, it could be seen as an opportunity for developing low-cost solutions for mass screening programs. PMID:29279773

  17. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.

    Science.gov (United States)

    Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg

    2015-01-01

    Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.

  18. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Directory of Open Access Journals (Sweden)

    Huang J

    2015-06-01

    Full Text Available Jingjing Huang,1 Jialiu Lin,1 Ziqiang Wu,2 Hongzhi Xu,3 Chengguo Zuo,1 Jian Ge1 1State Key Laboratory of Ophthalmology, Department of Glaucoma, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People’s Republic of China; 2Center for Advanced Eye Care, Carson City, NV, USA; 3Institute of Child Health Policy, University of Florida, Gainesville, FL, USA Purpose: The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries.Patients and methods: Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1 intraocular pressure (IOP ≥6 and ≤21 mmHg; 2 IOP reduction of at least 30% relative to preoperative values; and 3 without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications.Results: Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80 mm, corneal diameter was 14.71±1.07 (13.0–16.0 mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0, and IOP was 39.5±5.7 (30–55 mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18 months. There were significant reductions in IOPs and the number of glaucoma medications (P<0.001 postoperatively. The IOPs after operation were 11.3±3.4, 13.6±5.1, 16.3±2.7, and 16.1±2.6 mmHg at 1 month, 6 months, 12 months, and 18 months, respectively. Kaplan–Meier estimates of the cumulative probability of valve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28

  19. Supra-Tenon Capsule Implantation of the Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma.

    Science.gov (United States)

    Elhefney, Eman M; Al-Sharkawy, Hossam T; Kishk, Hanem M

    2016-09-01

    To evaluate the efficacy of supra-Tenon capsule implantation of an Ahmed glaucoma valve (AGV) as a measure to decrease the fibrotic potential of the Tenon capsule on bleb formation and its subsequent effect on intraocular pressure (IOP) control in children with refractory glaucoma. Mansoura Ophthalmic Centre, Faculty of Medicine, Mansoura University, Egypt. A prospective interventional study. Twenty-two eyes of 12 children with refractory glaucoma underwent supra-Tenon capsule implantation of AGV. Ophthalmic examinations under general anesthesia including measurement of the corneal diameter and the IOP with Perkin's tonometer were performed preoperatively, on the first postoperative day, the first postoperative week, weekly for the first month, 2-weekly for the following 3 months, and monthly for at least 18 months. Postoperative complications and the number of glaucoma medications used preoperatively and postoperatively were recorded. The paired Student t test was used to compare preoperative and postoperative data. There were 12 eyes (54.6%) with refractory congenital glaucoma, 7 eyes (31.8%) with refractory pseudophakic glaucoma, and 3 eyes (13.6%) with refractory aphakic glaucoma. Patients included 10 male (83.3%) and 2 female (16.7%) children with a mean age of 16.3±9.7 months. The mean follow-up duration was 24.1±4.3 months. There was a statistically significant difference between the mean preoperative IOP (30.7±2.88 mm Hg) and the mean postoperative IOP (16.1±3.60 mm Hg) (t=16.22 and P=0.000, with a mean decrease in the IOP by 47.6%). The difference between the mean number of antiglaucoma medications before surgery (1.86±0.4) and after surgery (1.0±0.9) was also statistically significant (t=4.31 and P=0.000). Total success was achieved in 18 eyes (81.9%). Postoperative complications included tube exposure and slippage (10%), hypotony (10%), and hyphema (5%). Supra-Tenon capsule implantation of the AGV was successful in controlling the IOP with few

  20. Ultrasonic flow-through filtration of microparticles in a microfluidic channel using frequency sweep technique

    International Nuclear Information System (INIS)

    Seo, Dae Cheol; Ahn, Bong Young; Cho, Seung Hyun; Siddique, A. K. M. Ariful Haque; Kim, Cheol Gi

    2013-01-01

    Many studies have been conducted on the filtration of microparticles using the acoustic radiation force of ultrasonic standing wave. The present work concerns a flow-through particle filtration method by utilizing frequency varying ultrasound. The periodical frequency sweep of the ultrasonic standing wave translocates particles across a microchannel, where particles in fluid flow are filtrated without barriers. The present filtration technique in a microfluidic channel was proposed conceptually in the 1990s. However, its experimental realization on actual particles in a microfluidic channel has not been carried out in a notable way. Several sizes of polystyrene microspheres (10 µm to 90 µm) and silicon carbide (SiC) particles (37 µm) suspended in water were applied as a test sample. For filtration of those particles, a Y-branched microfluidic channel with one inlet and two outlets was made out of steel and acrylic as a form of modulized device. Ultrasound of a few MHz in band frequency (1.75 MHz to 3.05 MHz) was transmitted into one side of the channel wall to generate a standing wave field in fluid flow. The periodical frequency sweep operation showed successful filtration performance, whereby particles in water flowed into one outlet and purified water flowed into the other outlet of the Y branch of the channel.

  1. Caracterización del glaucoma juvenil

    Directory of Open Access Journals (Sweden)

    Silvia Roche Caso

    2011-03-01

    Full Text Available INTRODUCCIÓN. El glaucoma no es frecuente en los niños, pero cuando ocurre sus síntomas son poco perceptibles y produce graves consecuencias para la salud visual. El objetivo de este estudio fue caracterizar, desde las aristas clínica y epidemiológica, a los pacientes con glaucoma juvenil atendidos en los servicios de oftalmología de los Hospitales Pediátricos del Cerro y «Pedro Borrás», en Ciudad de La Habana, en el período comprendido entre enero de 2008 y diciembre de 2009. MÉTODOS. Se realizó un estudio epidemiológico longitudinal y prospectivo, cuyo universo estuvo constituido por 176 pacientes entre 5 y 18 años de edad, con presunto glaucoma. La muestra, después de aplicados los criterios de inclusión y exclusión, quedó conformada por 38 casos. Se analizaron las variables: edad al momento del diagnóstico, sexo, color de la piel, antecedentes familiares según grado de parentesco, agudeza visual máxima corregida, tipo de defecto refractivo, características del ángulo camerular, espesor corneal central, valor de la presión intraocular, alteraciones fundoscópicas y campimétricas. RESULTADOS. En la mayoría de los pacientes el diagnóstico de glaucoma juvenil constituyó un hallazgo. La mediana de edad al momento del diagnóstico fue de 12,5 años, con ligero predominio de varones y de la piel no blanca. Fue más frecuente el antecedente de glaucoma en familiares de segundo grado de consanguinidad. La mayoría de los casos tenía visión óptima, algún grado de miopía y ángulo abierto sin alteraciones evidentes del ángulo camerular, entre las cuales la más frecuente fue la presencia de procesos iridianos prominentes. CONCLUSIONES. Predominaron la disminución moderada del espesor corneal y valores medios de presión intraocular de 26,91 mm Hg. La alteración fundoscópica encontrada con mayor frecuencia fue la excavación papilar moderada (entre 0,4 y 0,5 y como lesión campimétrica, el aumento de la mancha

  2. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  3. Costs of a community-based glaucoma detection programme: analysis of the Philadelphia Glaucoma Detection and Treatment Project.

    Science.gov (United States)

    Pizzi, Laura T; Waisbourd, Michael; Hark, Lisa; Sembhi, Harjeet; Lee, Paul; Crews, John E; Saaddine, Jinan B; Steele, Deon; Katz, L Jay

    2018-02-01

    Glaucoma is the foremost cause of irreversible blindness, and more than 50% of cases remain undiagnosed. Our objective was to report the costs of a glaucoma detection programme operationalised through Philadelphia community centres. The analysis was performed using a healthcare system perspective in 2013 US dollars. Costs of examination and educational workshops were captured. Measures were total programme costs, cost/case of glaucoma detected and cost/case of any ocular disease detected (including glaucoma). Diagnoses are reported at the individual level (therefore representing a diagnosis made in one or both eyes). Staff time was captured during site visits to 15 of 43 sites and included time to deliver examinations and workshops, supervision, training and travel. Staff time was converted to costs by applying wage and fringe benefit costs from the US Bureau of Labor Statistics. Non-staff costs (equipment and mileage) were collected using study logs. Participants with previously diagnosed glaucoma were excluded. 1649 participants were examined. Mean total per-participant examination time was 56 min (SD 4). Mean total examination cost/participant was $139. The cost/case of glaucoma newly identified (open-angle glaucoma, angle-closure glaucoma, glaucoma suspect, or primary angle closure) was $420 and cost/case for any ocular disease identified was $273. Glaucoma examinations delivered through this programme provided significant health benefit to hard-to-reach communities. On a per-person basis, examinations were fairly low cost, though opportunities exist to improve efficiency. Findings serve as an important benchmark for planning future community-based glaucoma examination programmes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Latanoprost systemic exposure in pediatric and adult patients with glaucoma

    DEFF Research Database (Denmark)

    Raber, Susan; Courtney, Rachel; Maeda-Chubachi, Tomoko

    2011-01-01

    To evaluate short-term safety and steady-state systemic pharmacokinetics (PK) of latanoprost acid in pediatric subjects with glaucoma or ocular hypertension who received the adult latanoprost dose.......To evaluate short-term safety and steady-state systemic pharmacokinetics (PK) of latanoprost acid in pediatric subjects with glaucoma or ocular hypertension who received the adult latanoprost dose....

  5. Some diagnostic and therapeutic controversies in glaucoma addressed

    NARCIS (Netherlands)

    Müskens, Rogier Peter Hendrik Maria

    2008-01-01

    In the five studies contained in this thesis, several controversies on the diagnosis of and therapy for glaucoma have been addressed. The first part of this thesis consisted of three studies that aimed tot improve existing technologies for diagnosing glaucoma. The latter part consisted of two

  6. Traumatic glaucoma with features of unilateral pigment dispersion.

    Science.gov (United States)

    Bowler, Gordon; Ellul, Antony; Gouws, Pieter

    2014-01-01

    We report a patient with traumatic glaucoma with features of unilateral pigment dispersion. This rare form of secondary glaucoma has only been reported twice previously, with both patients demonstrating angle recession, indicating associated damage to the trabecular meshwork. To our knowledge, this is the first such case reported in which angle recession was absent.

  7. Clinical Features of Primary Glaucoma in South East Nigeria ...

    African Journals Online (AJOL)

    Background: The clinical course of glaucoma depends on the type, onset, severity and response to treatment. The intraocular pressure and heredity also play a role in its presentation as members of the same family tend to have the same type of glaucoma. This paper seeks to address the problem of primary open angle ...

  8. Shared Care in Monitoring Stable Glaucoma Patients: A Randomized Controlled Trial

    NARCIS (Netherlands)

    Holtzer-Goor, Kim M.; van Vliet, Ellen J.; van Sprundel, Esther; Plochg, Thomas; Koopmanschap, Marc A.; Klazinga, Niek S.; Lemij, Hans G.

    2016-01-01

    Comparing the quality of care provided by a hospital-based shared care glaucoma follow-up unit with care as usual. This randomized controlled trial included stable glaucoma patients and patients at risk for developing glaucoma. Patients in the Usual Care group (n=410) were seen by glaucoma

  9. Prevalence and determinants of glaucoma : an epidemiologic approach (The Rotterdam Study)

    NARCIS (Netherlands)

    I. Dielemans (Ida)

    1995-01-01

    textabstractGlaucoma is an eye disease characterized by damage to the optic nerve head and related visual field defects, often accompanied by elevated intraocular pressure. Glaucoma is an important cause of blindness, particularly in the elderly. One may divide glaucoma in primary glaucoma without

  10. EM Task 9 - Centrifugal membrane filtration

    International Nuclear Information System (INIS)

    Stepan, Daniel J.; Stevens, Bradley G.; Hetland, Melanie D.

    1999-01-01

    The overall project consists of several integrated research phases related to the applicability, continued development, demonstration, and commercialization of the SpinTek centrifugal membrane filtration process. Work performed during this reporting period consisted of Phase 2 evaluation of the SpinTek centrifugal membrane filtration technology and Phase 3, Technology Partnering. During Phase 1 testing conducted at the EERC using the SpinTek ST-IIL unit operating on a surrogate tank waste, a solids cake developed on the membrane surface. The solids cake was observed where linear membrane velocities were less than 17.5 ft/s and reduced the unobstructed membrane surface area up to 25%, reducing overall filtration performance. The primary goal of the Phase 2 research effort was to enhance filtration performance through the development and testing of alternative turbulence promoter designs. The turbulence promoters were designed to generate a shear force across the entire membrane surface sufficient to maintain a self-cleaning membrane capability and improve filtration efficiency and long-term performance. Specific Phase 2 research activities included the following: System modifications to accommodate an 11-in.-diameter, two-disk rotating membrane assembly; Development and fabrication of alternative turbulence promoter designs; Testing and evaluation of the existing and alternative turbulence promoters under selected operating conditions using a statistically designed test matrix; and Data reduction and analysis; The objective of Phase 3 research was to demonstrate the effectiveness of SpinTek's centrifugal membrane filtration as a pretreatment to remove suspended solids from a liquid waste upstream of 3M's WWL cartridge technology for the selective removal of technetium (Tc)

  11. Mathematics model of filtration efficiency of moisture separator for nuclear reactors

    International Nuclear Information System (INIS)

    Zhang Zhenzhong; Jiang Feng; Huang Yunfeng

    2010-01-01

    In order to study the filtration mechanism of the moisture separator for water droplet of 5∼10μm, this paper set up a physical model. For the mixed meshes, they can be classified into three types: standard meshes, bur meshes and middle meshes. For all fibers of the wire meshes and vertical fibers of standard mixed meshes, a Kuwabara flow field is used to track the particle to get the inertial impaction efficiency and then calculate the total filtration efficiency of the meshes. For other fibers, besides the Kuwabara flow field, an around-flat flow field is added to calculate the efficiency. Lastly, the total efficiency of the moisture separator according to the equation of the filtration efficiency for the filters in series is compared with the experimental data. The result shows that, under the standard condition,the calculation value is consistent with the experimental efficiency data. (authors)

  12. Filtration of aluminum alloys and its influence on mechanical properties and shape of eutectical silicium

    Directory of Open Access Journals (Sweden)

    M. Brůna

    2008-07-01

    Full Text Available Filtration during casting of high quality aluminum alloys belongs to main refining methods. Even when there are many years of experiences and experimental works on this subject, there are still some specific anomalies. While using ceramic filtration media during casting of aluminum alloys, almost in all experiments occurred increase of strength limit and atypical increase of extension. This anomaly was not explained with classical metallurgical methods, black-white contrast after surface etching neither with color surface etching. For that reason was used deep etching on REM. By using pressed ceramic filters, by studying morphology eutectical silicon was observed modification morphology of eutectical silicon, this explains increase extension after filtration. Pressed ceramic filters were used on experimental works. Casting was executed on hardenable alloy AlSi10MgMn.

  13. Estimating filtration coefficients for straining from percolation and random walk theories

    DEFF Research Database (Denmark)

    Yuan, Hao; Shapiro, Alexander; You, Zhenjiang

    2012-01-01

    In this paper, laboratory challenge tests are carried out under unfavorable attachment conditions, so that size exclusion or straining is the only particle capture mechanism. The experimental results show that far above the percolation threshold the filtration coefficients are not proportional...... size exclusion theory or the model of parallel tubes with mixing chambers, where the filtration coefficients are proportional to the flux through smaller pores, and the predicted penetration depths are much lower. A special capture mechanism is proposed, which makes it possible to explain...... the experimentally observed power law dependencies of filtration coefficients and large penetration depths of particles. Such a capture mechanism is realized in a 2D pore network model with periodical boundaries with the random walk of particles on the percolation lattice. Geometries of infinite and finite clusters...

  14. Vacuum distillation/vapor filtration water recovery

    Science.gov (United States)

    Honegger, R. J.; Neveril, R. B.; Remus, G. A.

    1974-01-01

    The development and evaluation of a vacuum distillation/vapor filtration (VD/VF) water recovery system are considered. As a functional model, the system converts urine and condensates waste water from six men to potable water on a steady-state basis. The system is designed for 180-day operating durations and for function on the ground, on zero-g aircraft, and in orbit. Preparatory tasks are summarized for conducting low gravity tests of a vacuum distillation/vapor filtration system for recovering water from urine.

  15. Statistical data filtration in neutron coincidence counting

    International Nuclear Information System (INIS)

    Beddingfield, D.H.; Menlove, H.O.

    1992-11-01

    We assessed the effectiveness of statistical data filtration to minimize the contribution of matrix materials in 200-ell drums to the nondestructive assay of plutonium. Those matrices were examined: polyethylene, concrete, aluminum, iron, cadmium, and lead. Statistical filtration of neutron coincidence data improved the low-end sensitivity of coincidence counters. Spurious data arising from electrical noise, matrix spallation, and geometric effects were smoothed in a predictable fashion by the statistical filter. The filter effectively lowers the minimum detectable mass limit that can be achieved for plutonium assay using passive neutron coincidence counting

  16. The Perspective of Riverbank Filtration in China

    Science.gov (United States)

    Li, J.; Teng, Y.; Zhai, Y.; Zuo, R.

    2014-12-01

    Sustainable drinking water supply can affect the health of people, and the surrounding ecosystems. According to statistics of the monitoring program of drinking water sources in 309 at or above prefecture level of China in 2013, the major pollutants index were total phosphorus, ammonia and manganese in surface drinking water sources, respectively, iron, ammonia and manganese in groundwater drinking water sources, respectively. More than 150 drinking water emergency environmental accidents happened since 2006, 52 of these accidents led to the disruption of water supply in waterworks, and a population of over ten million were affected. It indicated that there is a potential risk for people's health by the use of river water directly and it is necessary to require alternative techniques such as riverbank filtration for improving the drinking water quality. Riverbank filtration is an inexpensive natural process, not only smoothing out normal pollutant concentration found in surface water but also significantly reducing the risk from such emergency events as chemical spill into the river. Riverbank filtration technique has been used in many countries more than 100 years, including China. In China, in 1950s, the bank infiltration technique was first applied in northeast of China. Extensive bank infiltration application was conducted in 1980s, and more than 300 drinking water sources utilities bank infiltration established mainly near the Songhua River Basin, the Yellow River Basin, Haihe River Basin. However, the comparative lack of application and researches on riverbank filtration have formed critical scientific data gap in China. As the performance of riverbank filtration technique depend on not only the design and setting such as well type, pumping rate, but also the local hydrogeology and environmental properties. We recommend more riverbank filtration project and studies to be conducted to collect related significant environmental geology data in China

  17. Industrial investigations of the liquid steel filtration

    Directory of Open Access Journals (Sweden)

    K. Janiszewski

    2014-07-01

    Full Text Available Hitherto existing investigations concerning the ceramic filter use in the steel making processes have given good results. The obtained results of filtration have proved that this method may be used as an effective and cheap way of steel filtration from non-metallic inclusions. Placing filters in the tundish is the best location considering the limitation of the possibility of secondary pollution of steel. Yet, the results presented in this paper, of an experiment prepared and carried out in the industrial environment, are the only positive results obtained, which are connected with so much quantities of liquid steel processed with use of the multi-hole ceramic filters.

  18. Marijuana for Glaucoma: A Recipe for Disaster or Treatment?

    Science.gov (United States)

    Sun, Xiaoshen; Xu, Chaoying S; Chadha, Nisha; Chen, Allshine; Liu, Ji

    2015-09-01

    Marijuana has been shown to lower intraocular pressure (IOP) but with limited duration of action and numerous adverse effects. Use of marijuana to lower IOP as a means of glaucoma treatment would require frequent use throughout the day, leading to significant adverse effects, possible progression toward Cannabis Use Disorder (CUD), and/or withdrawal symptoms. The treatment of glaucoma based on the cannabis plant or drugs based on the cannabinoid molecule should be considered carefully before being prescribed. Considerations should include the adverse physical and psychological adverse effects, including substance abuse. Currently, the deleterious effects of marijuana outweigh the benefits of its IOP-lowering capacity in most glaucoma patients. Under extremely rare circumstances, a few categories of glaucoma patients may be potential candidates for treatment with medical marijuana. Further studies on alternate routes and more focused means of cannabinoid molecule delivery to the eye for glaucoma treatment are needed.

  19. No evidence of a causal relationship between hypothyroidism and glaucoma

    DEFF Research Database (Denmark)

    Thvilum, Marianne; Brandt, Frans; Brix, Thomas Heiberg

    2018-01-01

    Background An interrelationship between hypothyroidism and glaucoma, due to a shared autoimmune background or based on deposition of mucopolysaccharides in the trabecular meshwork in the eye, has been suggested but is at present unsubstantiated. Therefore, our objective was to investigate......-hypothyroid controls according to age and sex. Prevalence of glaucoma was recorded and cases and controls were followed over a mean of 7.1 years (range 0±17). Logistic and Cox regression models were used to assess the risk of glaucoma before and after the diagnosis of hypothyroidism, respectively. Results Overall, we...... found a higher prevalence of glaucoma in subjects with hypothyroidism as compared to controls (4.6% vs. 4.3%, p glaucoma [1.09; 95% confidence interval (CI): 1.04-1.13]. Based on the Cox regression...

  20. Retinal oxygen saturation before and after glaucoma surgery.

    Science.gov (United States)

    Nitta, Eri; Hirooka, Kazuyuki; Shimazaki, Takeru; Sato, Shino; Ukegawa, Kaori; Nakano, Yuki; Tsujikawa, Akitaka

    2017-08-01

    This study compared retinal vessel oxygen saturation before and after glaucoma surgery. Retinal oxygen saturation in glaucoma patients was measured using a non-invasive spectrophotometric retinal oximeter. Adequate image quality was found in 49 of the 108 consecutive glaucoma patients recruited, with 30 undergoing trabeculectomy, 11 EX-PRESS and eight trabeculotomy. Retinal oxygen saturation measurements in the retinal arterioles and venules were performed at 1 day prior to and at approximately 10 days after surgery. Statistical analysis was performed using a Student's t-test. After glaucoma surgery, intraocular pressure (IOP) decreased from 19.8 ± 7.7 mmHg to 9.0 ± 5.7 mmHg (p glaucoma surgery had an effect on the retinal venous oxygen saturation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Visual disability and quality of life in glaucoma patients.

    Science.gov (United States)

    Cesareo, Massimo; Ciuffoletti, Elena; Ricci, Federico; Missiroli, Filippo; Giuliano, Mario Alberto; Mancino, Raffaele; Nucci, Carlo

    2015-01-01

    Glaucoma is an optic neuropathy that can result in progressive and irreversible vision loss, thereby affecting quality of life (QoL) of patients. Several studies have shown a strong correlation between visual field damage and visual disability in patients with glaucoma, even in the early stages of the disease. Visual impairment due to glaucoma affects normal daily activities required for independent living, such as driving, walking, and reading. There is no generally accepted instrument for assessing quality of life in glaucoma patients; different factors involved in visual disability from the disease are difficult to quantify and not easily standardized. This chapter summarizes recent works from clinical and epidemiological studies, which describe how glaucoma affects the performance of important vision-related activities and QoL. © 2015 Elsevier B.V. All rights reserved.

  2. Clinical observation of Ahmed glaucoma valve implantation for refractory glaucoma by directly puncturing the sclerotic tunnel

    Directory of Open Access Journals (Sweden)

    Zhi-Ke Xu

    2015-02-01

    Full Text Available AIM: To observe the clinic effects and complication of Ahmed glaucoma valve(AGVimplantation in refractory glaucoma by using the 23G syringe needle direct puncture the sclerotic tunnel.METHODS: Forty-four cases(44 eyesof refractory glaucoma underwent AGV implantation by useing the 23G syringe needle direct puncture the sclerotic tunnel. The intraocular pressure(IOP, visual acuity, and complication of post-operation were contrasted with those of pre-operation. RESULTS:The success rate was 84.1%, the mean preoperative IOP in research group was 52.1±10.1mmHg, and the last follow up mean IOP was 15.6±6.9mmHg. Compared with the preoperative visual acuity, 11 eyes increased, 27 eyes had no changes and 6 eyes decreased. The main post-operative complications included shallow anterior chamber(4 eyes, choroidal detachment(3 eyes, drainage tube shift(1 eye, hyphema(6 eyes, drainage tube blockage(1 eye, expulsive choroidal hemorrhage(1 eye, and fiber wrap of drainage tray(5 eyes.CONCLUSION: AGV implantation by direct puncture the sclerotic tunnel is feasible and easy. It avoids of making sclerotic petal and the xenogenic sclera transplanting, simplified the operation technique, prevent the leakage of around tube. The shallow anterior chamber rate is lower. It is an effective procedure for refractory glaucoma.

  3. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pglaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  4. Nanotechnology and glaucoma: a review of the potential implications of glaucoma nanomedicine.

    Science.gov (United States)

    Kim, Nathaniel J; Harris, Alon; Gerber, Austin; Tobe, Leslie Abrams; Amireskandari, Annahita; Huck, Andrew; Siesky, Brent

    2014-04-01

    The purpose of this review is to discuss the evolution of nanotechnology and its potential diagnostic and therapeutic applications in the field of ophthalmology, particularly as it pertains to glaucoma. We reviewed literature using MEDLINE and PubMed databases with the following search terms: glaucoma, nanotechnology, nanomedicine, nanoparticles, ophthalmology and liposomes. We also reviewed pertinent references from articles found in this search. A brief history of nanotechnology and nanomedicine will be covered, followed by a discussion of the advantages and concerns of using this technology in the field of glaucoma. We will look at various studies concerning the development of nanomedicine, its potential applications in ocular drug delivery, diagnostic and imaging modalities and, surgical techniques. In particular, the challenges of assuring safety and efficacy of nanomedicine will be examined. We conclude that nanotechnology offers a novel approach to expanding diagnostic, imaging and surgical modalities in glaucoma and may contribute to the knowledge of disease pathogenesis at a molecular level. However, more research is needed to better elucidate the mechanism of cellular entry, the potential for nanoparticle cytotoxicity and the assurance of clinical efficacy.

  5. Comparison of axial lengths in occludable angle and angle-closure glaucoma-The Bhaktapur Glaucoma Study

    NARCIS (Netherlands)

    Thapa, S.S.; Paudyal, I.; Khanal, S.; Paudel, N.; van Rens, G.H.M.B.

    2011-01-01

    Purpose. To compare the anterior chamber depth (ACD) and axial length of eyes in a population-based sample among normal, occludable angle, and primary angle-closure glaucoma (PACG) groups. Methods. Totally, 3979 subjects from a population-based glaucoma prevalence study underwent complete ocular

  6. The Ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study

    NARCIS (Netherlands)

    de Jong, Leo A. M. S.

    2009-01-01

    The purpose of this study was to establish the efficacy and safety of the Ex-PRESS (Optonol Ltd., Neve Ilan, Israel) mini glaucoma shunt in open-angle glaucoma. This was a prospective, randomized trial. Eyes from enrolled patients were randomly assigned to either Ex-PRESS implantation under a

  7. Granular filtration for airborne particles : correlation between experiments and models

    Energy Technology Data Exchange (ETDEWEB)

    Golshahi, L.; Tan, Z. [Calgary Univ., AB (Canada). Schulich School of Engineering, Mechanical and Manufacturing Dept.; Abedi, J. [Calgary Univ., AB (Canada). Schulich School of Engineering, Chemical and Petroleum Engineering Dept.

    2009-10-15

    A new design for a packed bed granular filter was presented. The cylindrical packed bed was designed to filter particles in the range of approximately 10 nm to 15 {mu}m in diameter in different kinetic conditions and configurations. The aim of the study was to develop a precise empirical model to predict the filtration efficiency of the packed beds. A collision-type atomizer was used to generate polydisperse sodium chloride aerosol particles. The effect of flow rates was studied using a thermal mass flow meter. A regression analysis technique was used to determine the correlation between single granule and total packed bed efficiency for the entire granular filter. The experimental data were then compared with results obtained from the theoretical analysis. The least square method was used to correlate experimental data and to develop generalized equations for single granule efficiency. The study showed that the granular filter media has a high filtration efficiency for both micron and submicron particles. It was concluded that the effect of media thickness was more significant at higher flow rates than at lower flow rates. 10 refs., 3 figs.

  8. Understanding practice patterns of glaucoma sub-specialists in India

    Directory of Open Access Journals (Sweden)

    Nikhil S. Choudhari

    2017-10-01

    Full Text Available AIM: To obtain information on the prevailing practice patterns of glaucoma specialists in India. METHODS: Glaucoma specialists attending the Annual Conference of the Glaucoma Society of India (GSI were surveyed. This survey, conducted in 2013, was based on an interactive audience response system. RESULTS: The information was obtained from 146 glaucoma specialists. Approximately half (n=83; 57% had ≥10y of experience in managing glaucoma and were in institutional practice (n=74, 51%. Goldmann applanation tonometry was preferred by 103 (72% specialists whilst n=25 (17.4% used non-contact tonometer. Indentation gonioscopy was favoured by two-thirds (n=90, 66% whereas stereoscopic optic disc examination and visual fields using Humphrey perimeter was performed by a majority of the specialists surveyed (n=115, 86% and n=114; 83% respectively. Nearly three quarter specialists (n=96; 72% preferred optical coherence tomography for imaging. The primary choice for treatment of angle closure disease and primary open angle glaucoma was laser (iridotomy, n=117; 93% and medical management (prostaglandin analogue, n=104; 78%, respectively. Approximately only a third of the specialists surveyed (n=37; 28% were performing both trabeculectomy and implantation of a glaucoma drainage device and about half (n=64; 47% were not operating on congenital glaucoma at all. CONCLUSION: This survey has found conformance with preferred practice patterns in several areas of diagnosis and management of glaucoma, but there was diversity in a few areas. The information is a significant step towards improvement of glaucoma care in India, including planning for future strategies.

  9. Measurement of filtration efficiency of Nuclepore filters challenged with polystyrene latex nanoparticles: experiments and modeling

    International Nuclear Information System (INIS)

    Ling, Tsz Yan; Wang Jing; Pui, David Y. H.

    2011-01-01

    Membrane filtration has been demonstrated to be effective for the removal of liquid-borne nanoparticles (NPs). Such technique can be applied to purify and disinfect drinking water as well as remove NPs in highly pure chemicals used in the industries. This study aims to study the filtration process of a model membrane filter, the Nuclepore filter. Experiments were carried out using standard filtration tools and the nanoparticle tracking analysis (NTA) technique was used to measure particle (50–500 nm) concentration upstream and downstream of the filter to determine the filtration efficiency. The NTA technique has been calibrated using 150-nm polystyrene latex particles to determine its accuracy of particle concentration measurement. Measurements were found reliable within a certain concentration limit (about 10 8 –10 10 particles/cm 3 ), which is dependent on the camera settings during the measurement. Experimental results are comparable with previously published data obtained using the aerosolization method, validating the capability of the NTA technique. The capillary tube model modified from that developed for aerosol filtration was found to be useful to represent the experimental results, when a sticking coefficient of 0.15 is incorporated. This suggests that only 15% of the particle collisions with the filter results in successful attachment. The small sticking coefficient found can be explained by the unfavorable surface interactions between the particles and the filter medium.

  10. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    Science.gov (United States)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  11. Late-onset endophthalmitis secondary to exposed glaucoma tube implant in a rare case of paediatric glaucoma.

    Science.gov (United States)

    Ranganath, Akshatha; Hashim, Adnan

    2011-01-01

    Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae. The glaucoma tube was exposed due to erosion of the overlying conjunctiva with no visible pericardial graft. After control of active infection, he underwent tube revision surgery whereby the exposed tube was retained and repatched with a double-thickness pericardial patch graft. He did well following surgery with good control of IOP and restoration of vision. Conjunctival dehiscence with graft melting over the GDI tube presented a major risk factor for endophthalmitis. Prompt surgical revision of an exposed tube is highly recommended to avoid ocular morbidity.

  12. Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

    Directory of Open Access Journals (Sweden)

    Akshatha Ranganath

    2011-01-01

    Full Text Available Glaucoma drainage implants (GDIs are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae. The glaucoma tube was exposed due to erosion of the overlying conjunctiva with no visible pericardial graft. After control of active infection, he underwent tube revision surgery whereby the exposed tube was retained and repatched with a double-thickness pericardial patch graft. He did well following surgery with good control of IOP and restoration of vision. Conjunctival dehiscence with graft melting over the GDI tube presented a major risk factor for endophthalmitis. Prompt surgical revision of an exposed tube is highly recommended to avoid ocular morbidity.

  13. Resource Planning in Glaucoma: A Tool to Evaluate Glaucoma Service Capacity.

    Science.gov (United States)

    Batra, Ruchika; Sharma, Hannah E; Elaraoud, Ibrahim; Mohamed, Shabbir

    2017-12-28

    The National Patient Safety Agency (2009) publication advising timely follow-up of patients with established glaucoma followed several reported instances of visual loss due to postponed appointments and patients lost to follow-up. The Royal College of Ophthalmologists Quality Standards Development Group stated that all hospital appointments should occur within 15% of the intended follow-up period. To determine whether: 1. Glaucoma follow-up appointments at a teaching hospital occur within the requested time 2. Appointments are requested at appropriate intervals based on the NICE Guidelines 3. The capacity of the glaucoma service is adequate Methods: A two-part audit was undertaken of 98 and 99 consecutive patients respectively attending specialist glaucoma clinics. In the first part, the reasons for delayed appointments were recorded. In the second part the requested follow-up was compared with NICE guidelines where applicable. Based on the findings, changes were implemented and a re-audit of 100 patients was carried out. The initial audit found that although clinical decisions regarding follow-up intervals were 100% compliant with NICE guidelines where applicable, 24% of appointments were delayed beyond 15% of the requested period, due to administrative errors and inadequate capacity, leading to significant clinical deterioration in two patients. Following the introduction of an electronic appointment tracker and increased clinical capacity created by extra clinics and clinicians, the re-audit found a marked decrease in the percentage of appointments being delayed (9%). This audit is a useful tool to evaluate glaucoma service provision, assist in resource planning for the service and bring about change in a non-confrontational way. It can be widely applied and adapted for use in other medical specialities.

  14. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    Science.gov (United States)

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Ahmed glaucoma valve implantation for refractory glaucoma after sequential failed trabeculectomy

    Directory of Open Access Journals (Sweden)

    Zhi-Qin Wu

    2016-07-01

    Full Text Available AIM: To evaluate the safety and efficacy of Ahmed glaucoma valve implantation for refractory glaucoma after sequential failed trabeculectomy. METHODS: Thirty-six patients(36 eyeswith prior failed sequential trabeculectomy who underwent Ahmed glaucoma valve implantation were included. The intraocular pressure(IOP, best corrected visual acuity(BCVAand complications were ovserved and all the patients were followed up at least for 12mo. RESULTS: Mean preoperative IOP was 35.20±7.28mmHg and reduced to 10.15±3.34, 11.23±3.56, 15.63±5.72, 17.17±5.47, 17.73±6.23,19.76±5.43mmHg at 1, 2wk, 1, 3, 6 and 12mo after surgery, which was significant different from the preoperative level(t=12.643, 11.837, 10.324, 8.839, 8.462, 8.046, all PZ=-0.420, P>0.05. At 12mo after operation, the complete success rate reached 78% and the conditional success rate reached 92%. There were 5 eyes complicated with shallow anterior chamber, 3 eye complicated with anterior chamber hemorrhage, which all recovered after additional treatments. Late complications included valve exposure and encapsulated cystic blebs around the plate. Severe corneal endothelium loss occurred in 1 patient. CONCLUSION: Ahmed glaucoma valve implantation is effective in reducing IOP at 1-year follow-up in refractory glaucoma patients with prior sequential failed trabeculectomy, but we should fully understand and attach great importance to all kinds of complications that may occur.

  16. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure.

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56-30.80) mm, corneal diameter was 14.71±1.07 (13.0-16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9-1.0), and IOP was 39.5±5.7 (30-55) mmHg. The mean follow-up time was 18.29±10.96 (5-44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pvalve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications.

  17. Filtration of engineered nanoparticles using porous membranes

    NARCIS (Netherlands)

    Trzaskus, Krzystof

    2016-01-01

    The research presented in this thesis aims at providing a better understanding of the fundamental aspects responsible for nanoparticle removal and fouling development during filtration of engineered nanoparticles. The emphasis is put on the role of interparticle interactions in the feed solution,

  18. Dynamic membrane filtration in tangential flow

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Oil-containing waste water is produced in many cleaning processes and also on production of compressed air. Dynamic membrane filtration in the tangential flow mode has proved effective in the treatment of these stable emulsions. The possible applications of ceramic membrane filters are illustrated for a variety of examples. (orig.) [de

  19. Filtration aids in uranium ore processing

    International Nuclear Information System (INIS)

    Ford, H.L.; Levine, N.M.; Risdon, A.R.

    1975-01-01

    A process of improving the filtration efficiency and separation of uranium ore pulps obtained by carbonate leaching of uranium ore which comprises treating said ore pulps with an aqueous solution of hydroxyalkyl guar selected from the group consisting of hydroxyethyl and hydroxypropyl guar in the amount of 0.1 and 2.0 pounds of hydroxyalkyl guar per ton of uranium ore

  20. Filtration engineering study to upgrade the ETF

    International Nuclear Information System (INIS)

    McDonald, F.N.N.

    1995-01-01

    Filtration technologies are evaluated which have potential to augment or upgrade the 200 Area Effluent Treatment Facility. The study was written in anticipation of treating future waste waters that have high fouling potentials. The Three ultrafilters judged to be capable of treating future waste waters are: hollow fiber, tubular, and centrifugal

  1. Organic micropollutant removal during river bank filtration

    NARCIS (Netherlands)

    Bertelkamp, C.

    2015-01-01

    This study investigated the factors influencing the main removal mechanisms (adsorption and biodegradation) for organic micropollutant (OMP) removal during river bank filtration (RBF) and the possibility of developing a predictive model of this process for OMP removal during RBF. Chapter 2 analysed

  2. Gene therapy with brain-derived neurotrophic factor as a protection: retinal ganglion cells in a rat glaucoma model.

    Science.gov (United States)

    Martin, Keith R G; Quigley, Harry A; Zack, Donald J; Levkovitch-Verbin, Hana; Kielczewski, Jennifer; Valenta, Danielle; Baumrind, Lisa; Pease, Mary Ellen; Klein, Ronald L; Hauswirth, William W

    2003-10-01

    To develop a modified adenoassociated viral (AAV) vector capable of efficient transfection of retinal ganglion cells (RGCs) and to test the hypothesis that use of this vector to express brain-derived neurotrophic factor (BDNF) could be protective in experimental glaucoma. Ninety-three rats received one unilateral, intravitreal injection of either normal saline (n = 30), AAV-BDNF-woodchuck hepatitis posttranscriptional regulatory element (WPRE; n = 30), or AAV-green fluorescent protein (GFP)-WPRE (n = 33). Two weeks later, experimental glaucoma was induced in the injected eye by laser application to the trabecular meshwork. Survival of RGCs was estimated by counting axons in optic nerve cross sections after 4 weeks of glaucoma. Transgene expression was assessed by immunohistochemistry, Western blot analysis, and direct visualization of GFP. The density of GFP-positive cells in retinal wholemounts was 1,828 +/- 299 cells/mm(2) (72,273 +/- 11,814 cells/retina). Exposure to elevated intraocular pressure was similar in all groups. Four weeks after initial laser treatment, axon loss was 52.3% +/- 27.1% in the saline-treated group (n = 25) and 52.3% +/- 24.2% in the AAV-GFP-WPRE group (n = 30), but only 32.3% +/- 23.0% in the AAV-BDNF-WPRE group (n = 27). Survival in AAV-BDNF-WPRE animals increased markedly and the difference was significant compared with those receiving either AAV-GFP-WPRE (P = 0.002, t-test) or saline (P = 0.006, t-test). Overexpression of the BDNF gene protects RGC as estimated by axon counts in a rat glaucoma model, further supporting the potential feasibility of neurotrophic therapy as a complement to the lowering of IOP in the treatment of glaucoma.

  3. Secondary glaucoma in CAPN5-associated neovascular inflammatory vitreoretinopathy

    Directory of Open Access Journals (Sweden)

    Cham A

    2016-06-01

    Full Text Available Abdourahman Cham,1,2 Mayank Bansal,3 Himanshu K Banda,4 Young Kwon,1 Paul S Tlucek,1 Alexander G Bassuk,5 Stephen H Tsang,6,7 Warren M Sobol,8 James C Folk,1 Steven Yeh,4 Vinit B Mahajan1,2 1Department of Ophthalmology and Visual Sciences, 2Omics Laboratory, University of Iowa, Iowa City, IA, USA; 3Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India; 4Department of Ophthalmology, Emory University School of Medicine, Atlanta, GA, 5Department of Pediatrics, University of Iowa, Iowa City, IA, 6Barbara and Donald Jonas Laboratory of Stem Cells and Regenerative Medicine and Bernard and Shirlee Brown Glaucoma Laboratory, Department of Pathology and Cell Biology, Institute of Human Nutrition, College of Physicians and Surgeons, Columbia University, 7Edward S Harkness Eye Institute, New York-Presbyterian Hospital, New York, NY, 8Retina Physicians & Surgeons, Inc., Dayton, OH, USA Objective: The objective of this study was to review the treatment outcomes of patients with secondary glaucoma in cases of autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV, a hereditary autoimmune uveitis due to mutations in CAPN5. Patients and methods: A retrospective, observational case series was assembled from ADNIV patients with secondary glaucoma. The main outcome measures were intraocular pressure (IOP, visual acuity, use of antiglaucoma medications, ocular surgeries, and adverse outcomes. Perimetry and optic disk optical coherence tomography (OCT were also analyzed. Results: Nine eyes of five ADNIV patients with secondary glaucoma were reviewed. Each received a fluocinolone acetonide (FA implant for the management of posterior uveitis. Following implantation, no eyes developed neovascular glaucoma. Five eyes (in patients 1, 2, and 5 required Ahmed glaucoma valve surgery for the management of steroid-responsive glaucoma. Patient 2 also developed angle closure with iris bombe and underwent laser

  4. The Small Heat Shock Protein α-Crystallin B Shows Neuroprotective Properties in a Glaucoma Animal Model

    Directory of Open Access Journals (Sweden)

    Fabian Anders

    2017-11-01

    Full Text Available Glaucoma is a neurodegenerative disease that leads to irreversible retinal ganglion cell (RGC loss and is one of the main causes of blindness worldwide. The pathogenesis of glaucoma remains unclear, and novel approaches for neuroprotective treatments are urgently needed. Previous studies have revealed significant down-regulation of α-crystallin B as an initial reaction to elevated intraocular pressure (IOP, followed by a clear but delayed up-regulation, suggesting that this small heat-shock protein plays a pathophysiological role in the disease. This study analyzed the neuroprotective effect of α-crystallin B in an experimental animal model of glaucoma. Significant IOP elevation induced by episcleral vein cauterization resulted in a considerable impairment of the RGCs and the retinal nerve fiber layer. An intravitreal injection of α-crystallin B at the time of the IOP increase was able to rescue the RGCs, as measured in a functional photopic electroretinogram, retinal nerve fiber layer thickness, and RGC counts. Mass-spectrometry-based proteomics and antibody-microarray measurements indicated that a α-crystallin injection distinctly up-regulated all of the subclasses (α, β, and γ of the crystallin protein family. The creation of an interactive protein network revealed clear correlations between individual proteins, which showed a regulatory shift resulting from the crystallin injection. The neuroprotective properties of α-crystallin B further demonstrate the potential importance of crystallin proteins in developing therapeutic options for glaucoma.

  5. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2018-01-01

    Full Text Available Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP, best-corrected visual acuity (BCVA, number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results. The mean follow-up duration was 11.7 ± 5.5 (range, 6–23 months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001 and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021. At the last visit, 11 eyes (84.4% had stable or improved VA and one eye (7.7% had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%. Postoperative complications were bleb encapsulation (69.2%, early hypotony (38.5%, hyphema (23.1%, decompression retinopathy (23.1%, choroidal detachment (15.4%, intraocular hemorrhage (7.7%, and late endophthalmitis (7.7%. One eye (7.7% was enucleated because of late endophthalmitis. Conclusions. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  6. A novel implantable glaucoma valve using ferrofluid.

    Directory of Open Access Journals (Sweden)

    Eleftherios I Paschalis

    Full Text Available PURPOSE: To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. SETTING: Massachusetts Eye & Ear Infirmary, Boston, USA. METHODS: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. RESULTS: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg. X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. CONCLUSIONS: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.

  7. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.

    Science.gov (United States)

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  8. Algorithmic impediments filtration using the α-truncated mean method in resolver-to-digital converter

    Directory of Open Access Journals (Sweden)

    Gordiyenko V. I.

    2009-02-01

    Full Text Available A test diagram of the microcontroller-type resolver-to-digital converter and algorithms for impediments filtration therein are developed. Experimental verification of the α-truncated mean algorithm intended for the suppression of impulse and noise interference is conducted. The test results are given.

  9. Interocular asymmetry of the visual field defects in newly diagnosed normal-tension glaucoma, primary open-angle glaucoma, and chronic angle-closure glaucoma.

    Science.gov (United States)

    Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun

    2014-09-01

    To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.

  10. Predicting Vision-Related Disability in Glaucoma.

    Science.gov (United States)

    Abe, Ricardo Y; Diniz-Filho, Alberto; Costa, Vital P; Wu, Zhichao; Medeiros, Felipe A

    2018-01-01

    To present a new methodology for investigating predictive factors associated with development of vision-related disability in glaucoma. Prospective, observational cohort study. Two hundred thirty-six patients with glaucoma followed up for an average of 4.3±1.5 years. Vision-related disability was assessed by the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) at baseline and at the end of follow-up. A latent transition analysis model was used to categorize NEI VFQ-25 results and to estimate the probability of developing vision-related disability during follow-up. Patients were tested with standard automated perimetry (SAP) at 6-month intervals, and evaluation of rates of visual field change was performed using mean sensitivity (MS) of the integrated binocular visual field. Baseline disease severity, rate of visual field loss, and duration of follow-up were investigated as predictive factors for development of disability during follow-up. The relationship between baseline and rates of visual field deterioration and the probability of vision-related disability developing during follow-up. At baseline, 67 of 236 (28%) glaucoma patients were classified as disabled based on NEI VFQ-25 results, whereas 169 (72%) were classified as nondisabled. Patients classified as nondisabled at baseline had 14.2% probability of disability developing during follow-up. Rates of visual field loss as estimated by integrated binocular MS were almost 4 times faster for those in whom disability developed versus those in whom it did not (-0.78±1.00 dB/year vs. -0.20±0.47 dB/year, respectively; P disability developing over time (odds ratio [OR], 1.34; 95% confidence interval [CI], 1.06-1.70; P = 0.013). In addition, each 0.5-dB/year faster rate of loss of binocular MS during follow-up was associated with a more than 3.5 times increase in the risk of disability developing (OR, 3.58; 95% CI, 1.56-8.23; P = 0.003). A new methodology for classification and analysis

  11. Use of gonioscopy in medicare beneficiaries before glaucoma surgery.

    Science.gov (United States)

    Coleman, Anne L; Yu, Fei; Evans, Stacy J

    2006-12-01

    The American Academy of Ophthalmology Preferred Practice Patterns for angle closure and open-angle glaucoma (OAG) patients recommends performing bilateral gonioscopy upon initial presentation to evaluate the possibility of narrow angle or angle-closure glaucoma (ACG) and then repeating the examination at least every 5 years. This study aims to assess how commonly eye care providers perform gonioscopy before planned glaucoma surgery in OAG, anatomic narrow angle, and ACG in the Medicare population. Data obtained from a 5% random sample of Medicare beneficiaries undergoing glaucoma surgery in the United States in 1999 were retrospectively reviewed. The proportion of patients with evidence of at least one gonioscopic examination before glaucoma surgery was determined for the period of 1995 to 1999. Demographic and clinical factors potentially influencing the decision to perform gonioscopy were also examined. Overall, gonioscopy is apparently performed in 49% of Medicare beneficiaries during the 4 to 5 years preceding glaucoma surgery. This rate was significantly lower (P gonioscopy rates (P Gonioscopy examination before glaucoma surgery in Medicare beneficiaries is underused, undercoded, and/or miscoded, given current recommendations. Underuse is of particular concern in patients undergoing laser iridotomy as it is the diagnostic test of choice in ACG.

  12. Traumatic glaucoma due to paintball injuries: A case series

    Directory of Open Access Journals (Sweden)

    Kelly M. Lee

    2017-12-01

    Full Text Available Purpose: To study the management and outcomes of patients with paintball injuries resulting in traumatic glaucoma. Methods: A retrospective review was performed, identifying four patients with a confirmed diagnosis of traumatic glaucoma secondary to paintball sports. Results: Four male patients with paintball gun injuries presented with a mean follow-up time of 51 months after the date of injury. The mean age was 23.5 ± 18.6 years. Three patients presented with blunt trauma, while one patient had a ruptured globe. Presenting visual acuity (VA was hand motions in three of the patients and no light perception in the fourth patient. All patients were diagnosed with traumatic glaucoma and treated with glaucoma medications during their follow-up. Two patients received tube shunts to control intraocular pressures (IOPs. At the time of most recent follow-up, three patients had elevated IOPs and were not on any medications. VA at the last follow-up was 20/400 or worse. Conclusions: Traumatic glaucoma can be managed with surgical and medical interventions, while VA usually does not return to baseline levels prior to the injury. Prognostic predictors can be used to guide treatment and identify patients who should be closely followed. Because the presentation and onset is widely variable, follow-up and screening is crucial even years after the injury. Keywords: Paintball, Ocular trauma, Glaucoma, Secondary glaucoma

  13. Anticlotting agents and the surgical management of glaucoma.

    Science.gov (United States)

    Sozeri, Yasemin; Salim, Sarwat

    2018-03-01

    A large subset of patients with glaucoma uses anticlotting agents. No standardized guidelines currently exist for managing these agents in the specific perioperative setting of glaucoma surgery. The present review focuses on currently available anticlotting agents, their influence on hemorrhagic complications following glaucoma surgery, and management strategies for their use in the perioperative period RECENT FINDINGS: Anticlotting agents increase the risk of perioperative hemorrhagic complications following glaucoma surgery. Other factors that increase that risk have been identified as well, including the type of glaucoma surgery, preoperative intraocular pressure, postoperative hypotony, previous ocular surgeries, and race. Although general guidelines in the perioperative management of blood thinning agents exist, the best way to apply these guidelines specifically to glaucoma surgery remains unclear. Blood thinners are widely used and can increase the risk of hemorrhagic complications in patients undergoing glaucoma surgery. Managing these agents in the perioperative setting is challenging and should be done in collaboration with the patient's primary care provider, hematologist, or cardiologist. Management strategies should be tailored to each individual's risk of hemorrhage versus thromboembolism. Additionally, surgical plans can be modified to help minimize hemorrhagic outcomes, especially in patients who are deemed to be at high risk for perioperative bleeding.

  14. Glaucoma associated with the management of rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Mangouritsas G

    2013-04-01

    Full Text Available George Mangouritsas, Spyridon Mourtzoukos, Dimitra M Portaliou, Vassilios I Georgopoulos, Anastasia Dimopoulou, Elias Feretis Eye Clinic, General Hospital "Hellenic Red Cross", Athens, Greece Abstract: Transient or permanent elevation of intraocular pressure (IOP is a common complication following vitreoretinal surgery. Usually secondary glaucoma, which develops after scleral buckling procedures, or pars plana vitrectomy for repair of rhegmatogenous retinal detachment, is of multifactorial origin. It is essential, for appropriate management, to detect the cause of outflow obstruction. An exacerbation of preexisting open-angle glaucoma or a steroid-induced elevation of IOP should also be considered. Scleral buckling may be complicated by congestion and anterior rotation of the ciliary body resulting in secondary angle closure, which can usually resolve with medical therapy. The use of intravitreal gases may also induce secondary angle-closure with or without pupillary block. Aspiration of a quantity of the intraocular gas may be indicated. Secondary glaucoma can also develop after intravitreal injection of silicone oil due to pupillary block, inflammation, synechial angle closure, or migration of emulsified silicone oil in the anterior chamber and obstruction of the aqueous outflow pathway. In most eyes medical therapy is successful in controlling IOP; however, silicone oil removal with or without concurrent glaucoma surgery may also be required. Diode laser transscleral cyclophotocoagulation and glaucoma drainage devices constitute useful treatment modalities for long-term IOP control. Cooperation between vitreoretinal and glaucoma specialists is necessary to achieve successful management. Keywords: retinal detachment, intraocular pressure elevation, glaucoma, vitrectomy, intravitreal gas, silicone oil

  15. Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

    Directory of Open Access Journals (Sweden)

    Cheng CS

    2016-07-01

    Full Text Available Clarissa Shu Ming Cheng,1,2 Yi Fang Lee,2 Charles Ong,3 Zhu Li Yap,2 Andrew Tsai,2 Aditi Mohla,2 Monisha E Nongpiur,4 Tin Aung,2,4 Shamira A Perera2,4 1Department of Ophthalmology, Tan Tock Seng Hospital, 2Department of Ophthalmology, Singapore National Eye Centre, 3Yong Loo Lin School of Medicine, National University of Singapore, 4Singapore Eye Research Institute, Singapore National Eye Centre, Singapore Background: To compare retinal vessel oxygenation and vessel caliber in primary angle-closure glaucoma (PACG, primary open-angle glaucoma (POAG, normal-tension glaucoma (NTG, and normal controls, as well as between eyes of asymmetrical glaucoma severity.Methods: This was a prospective, cross-sectional study. The 159 subjects (PACG, n=39; POAG, n=41; NTG, n=41; normal controls, n=38 underwent retinal oxygen saturation measurements using the Oxymap T1 Retinal Oximeter, optical coherence tomography, and Humphrey visual field testing. Retinal oxygen saturation and vessel diameter were compared between the glaucoma groups and normal controls, as well as between eyes of asymmetrical glaucoma severity. Kruskal–Wallis test was performed for comparison among different subtypes of glaucoma. Wilcoxon signed-rank test was used to compare the inter-eye differences.Results: Compared to normal controls, arteriolar oxygen saturation was increased in PACG eyes (P=0.048 but not in POAG or NTG eyes. There were no significant differences in oxygen saturation in venules or arteriovenous (AV difference in all three glaucoma groups. Venular diameter was significantly reduced in all glaucoma groups compared to normal controls (P<0.001, but no such change was observed in arteriolar diameter (P=0.10. When comparing between eyes of asymmetrical glaucoma severity, arteriolar oxygen saturation (P=0.03 and AV difference (P=0.04 were significantly higher, while arteriolar diameter was significantly lower (P=0.001 in the worse eye in PACG group. There were no significant

  16. Profile of glaucoma in a major eye hospital in North India

    Directory of Open Access Journals (Sweden)

    Das Jayachandra

    2001-01-01

    Full Text Available Purpose: To study the clinical profile and distribution of various subtypes of glaucoma in a referral practice in North India. Method: A retrospective analysis was done of 2425 patients who attended the glaucoma clinic in a tertiary eye-care centre for five years from Januaryl995 to December 1999. A detailed history was obtained and a thorough examination was performed, including gonioscopy, disc assessment, applanation tonometry and automated perimetry. Diurnal variation of IOP and provocative tests for glaucoma were done where applicable. Result: Primary angle closure glaucoma (PACG was the most common glaucoma subtype. The primary open angle glaucoma (POAG to the PACG ratio was 37:63. Chronic angle closure glaucoma (CACG was the most common PACG subtype. The majority of CACG cases were relatively asymptomatic. Male dominance was seen for POAG, juvenile open angle glaucoma (JOAG, CACG, normal tension glaucoma (NTG and secondary glaucomas. Female dominance was seen for ocular hypertension (OHT, acute or intermittent ACG and developmental glaucomas. The mean age in years at presentation was POAG: 60.54 years (males 61.54 years, females 59.01 years and PACG: 55.13 years (males 57.25 years, females 53.60. The three common secondary glaucomas were: glaucoma secondary to adherent leucoma, aphakic and pseudophakic glaucomas and traumatic glaucomas. Advanced glaucoma was detected in 42 to 53% of patients and bilateral blindness in 8 to 14% of patients in various subtypes. Conclusion: Compared to Caucasians, glaucoma patients in North India seem to present nearly a decade earlier and the disease is more advanced at presentation. While PACG is the most commonly encountered glaucoma, NTG and exfoliative glaucoma are relatively rare.

  17. Modeling Non-Fickian Transport and Hyperexponential Deposition for Deep Bed Filtration

    DEFF Research Database (Denmark)

    Yuan, Hao; Shapiro, Alexander

    2010-01-01

    An integral model of the deep bed filtration process has been developed. It incorporates pore and particle size distributions, as well as the particle residence time distribution in the framework of the continuous time random walk theory. Numerical modeling is carried out to study the factors...... influencing breakthrough curves and deposition profiles for the deep bed filtration systems. Results are compared with a large set of experimental observations. Our findings show that highly dispersed breakthrough curves, e.g. those with early arrivals and large ending tails, correspond to large dispersion...

  18. OPTIMIZATION OF THE PROCESS OF DRYING THE FILTRATE DISTILLERY DREGS

    Directory of Open Access Journals (Sweden)

    A. A. Shevtsov

    2013-01-01

    Full Text Available The interactions of various factors affecting the process of drying the filtrate distillery dregs are investigated. Rational conditions for the process of drying the filtrate distillery dregs in a spray dryer are obtained.

  19. Ganglion cell complex scan in the early prediction of glaucoma.

    Science.gov (United States)

    Ganekal, S

    2012-01-01

    To compare the macular ganglion cell complex (GCC) with peripapillary retinal fiber layer (RNFL) thickness map in glaucoma suspects and patients. Forty participants (20 glaucoma suspects and 20 glaucoma patients) were enrolled. Macular GCC and RNFL thickness maps were performed in both eyes of each participant in the same visit. The sensitivity and specificity of a color code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Standard Automated Perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. The statistical analysis was performed with the SPSS 10.1 (SPSS Inc. Chicago, IL, EUA). Results were expressed as mean +/- standard deviation and a p value of 0.05 or less was considered significant. Provide absolute numbers of these findings with their units of measurement. There was a statistically significant difference in average RNFL thickness (p=0.004), superior RNFL thickness (p=0.006), inferior RNFL thickness (p=0.0005) and average GCC (p=0.03) between the suspects and glaucoma patients. There was no difference in optic disc area (p=0.35) and vertical cup/disc ratio (p=0.234) in both groups. While 38% eyes had an abnormal GCC and 13% had an abnormal RNFL thickness in the glaucoma suspect group, 98% had an abnormal GCC and 90% had an abnormal RNFL thickness in the glaucoma group. The ability to diagnose glaucoma with macular GCC thickness is comparable to that with peripapillary RNFL thickness . Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma. © NEPjOPH.

  20. Glaucoma Blindness at a Tertiary Eye Care Center.

    Science.gov (United States)

    Stone, Jordan S; Muir, Kelly W; Stinnett, Sandra S; Rosdahl, Jullia A

    2015-01-01

    Glaucoma is an important cause of irreversible blindness. This study describes the characteristics of a large, diverse group of glaucoma patients and evaluates associations between demographic and clinical characteristics and blindness. Data were gathered via retrospective chart review of patients (N = 1,454) who were seen between July 2007 and July 2010 by glaucoma service providers at Duke Eye Center. Visual acuity and visual field criteria were used to determine whether patients met the criteria for legal blindness. Descriptive and comparative statistical analyses were performed on the glaucoma patients who were not blind (n = 1,258) and those who were blind (n = 196). A subgroup analysis of only those patients with primary open-angle glaucoma was also performed. In this tertiary care population, 13% (n = 196) of glaucoma patients met criteria for legal blindness, nearly one-half of whom (n = 94) were blind from glaucoma, and another one-third of whom (n = 69) had glaucoma-related blindness. The most common glaucoma diagnosis at all levels of vision was primary open-angle glaucoma. A larger proportion of black patients compared with white patients demonstrated vision loss; the odds ratio (OR) for blindness was 2.25 (95% CI, 1.6-3.2) for black patients compared with white patients. The use of systemic antihypertensive medications was higher among patients who were blind compared with patients who were not blind (OR = 2.1; 95% CI, 1.4-3.1). A subgroup analysis including only patients with primary open-angle glaucoma showed similar results for both black race and use of systemic antihypertensive medications. The relationship between use of systemic antihypertensive medications and blindness was not different between black patients and white patients (interaction P = .268). Data were based on chart review, and associations may be confounded by unmeasured factors. Treated systemic hypertension may be correlated with blindness, and the cause cannot be explained solely